Loading...
HomeMy WebLinkAbout18-19368 CITY OF ZEPHYRHILLS ' � 5335-8TH STREET z � , (813)780-0020 19368 �UILDING PERNIIT SINGLE FAMILY RESIDENTIAL PERMIT li'�IFORMATION -� = LOCATION INFORMATION Permit#:19368 Issued: 2/28/2018 Address: 6896 SILVERADO RANCH BLVD Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 266,079.30 Total Fees: 11,394.69 Subdivision: SILVERADO Amount Paid: 11,394.69 Date Paid: 2/27/2018 Parcel Number: 05-26-21-0080-00700-0020 CONTRACTOR INFORMATION OWNER INFORMATION Name: D R HORTON INC Name: DR HORTON INC Addr: 12602 TELECOM DR Address: 12602 TELECOM DR , TAMPA, FL. 33637 TEMPLE TE�RRACE FL 33637-0935 I Phone: Lic: Phone: 813-549-1968 � Work Desc: CONSTRUCT SINGLE FAMILY 2,362 SQ FT APPLICATION FEES BUILDING FEE 1,088.77 ELECTRICAL FEE 222.53 PLUMBING FEE 148.35 MECHANICAL FEE 103.85 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE-sfr/100% 4,828.00 SCHOOL IMPACT FEE-sfr/1% 48.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32 v � � � �v e��-� �� �� , ��� � � fns ections Re uired FOOTER 2ND ROUGH PLUMB MIS INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans, Specifications and Must Accompany Application.All work shall be perFormed in accordance with Ci Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONT CTORS SIGNATURE PERMIT OFFI I PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - � HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER � //I��n S /��o� o 4 f( [`���// t tAHiBfl (I��L� '�-v� �'�tr.'�sS�"f�'-`_ � � i�� ' l �J '� `�. -�i _ �' ` w� City of Zephyrhills BUILDING PLAN REVIEW COMIVIENTS Contractor/Homeowner: � � �jy�� Date Received: �" -2 2�� � Site: �., � 9 � � I�'�(� /��Q � c 1 �� Permit Type: � �i �e �c C Z Z=S � Approved w/no comments:❑ Approved w/the below comments:� Denied w/the below comments: ❑ P ' This comment sheet sha11 be kept with the pernut andlor plans. , ' '` �a���' � ��'� Kalvin S it r=Plans Examiner Date Contractor and/or Homeowner (Required when comments are present) \ � D R HORTON INC-6896 Silverado Ranch,Blvd="-2,362 sq ft ,. � . o umn SQ. FEET � PRICE MAIN OR LIVING: 2;,36�'' $ 112.65 OTHER AREA UNDER ROOF: = OTHER: - $ _ _ VALUATION $ 266,079.30 FEE SHEET $ 989.00 '' ADDRESS $ 40.00 DRIVEWAY $ 40.00 I� BUILDING: $ 1,088.78 ELECTRICAL: $ 222.53 � PLUMBING: $ 148.35 MECHANICAL: $ 103.85 'i SUB-TOTAL $ 1,563.50 � TOTAL $ 1,563.50 II SEW ER: n/a II WATER: n/a I IRRIGATION: $ - I TOTAL: $ - �� WATER METER: n/a IRRIGATION METER $ - , FIRE DEPARTMENT FEES PLANS TOTAL: INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ � 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 2,116.85 PARK IMPACT FEES $ 769.56 SIF'S: $ - 4,828.00 100.0°/a $ 4,828.00 1.0% $ 48.28 TOTAL: $ 4,876.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 11,394.69 � -- ----- CIT�If OF / / / / BUILDIN� t�PHYRHIL•LS DEPARTMENT OF ADDITION OR CORRECTION ' � • • - • ADDRE55 DATE PERMIT f l ��l/"�C�.�,U �c(' _ `�, THIS JOB HAS NOT BEEN COMPLETED. The foliowing additions or corrections shall be made before the job will be accepted. . �- It is unlawFul tor any Carpenter,Contractor,auilder,or other persons,to AFTER CORRECTIONS ARE MADE CALL cover or cause to be covered,any paR of the work with flooring,Iath,earth ' 78O-OOZO FOR RE- PEC ION or other material,until the proper inspector has had ample time to approve �', the installation. OFFICE HOURS 7:30AM-4:30 PM MON.-FRI. INSPECTOR � ; . _ . PASGQ GOUNTY DEVELOPMENT SERViCES � ����`��'t 8731 Citizens Drive Date:6/'f3l2Q18 , �OUNTY FLtJRID��� lVew Port Richey,FL 34654 � C}��,v Sr:�c�.Yy+Yuu�r l�v�crs, ?27-847-2411 . '�c�k 4 �!�.J 1 � i ��61/��� �'s'; Receipt#: '1767575 FEE DESGRIRTION ACCOUNT CBDE UNITS tNVO10E# FEE AM4UNT PAID RECEIPT# QATE Impact Fee Residential Solid 245Q3104-3294/0 34.48 4353816 $34.48 $34.48 1767575 6/13118 Waste Single Family TOTALS: $34.4$ $34.48 ecei t# Paid Bv Check# CC Auth# Cashier tD Warkstation Reaei,pt Date Amt Paid 't767575 Check 0�59947 540 BCGGPO6W 08l13/2098 $34.48 Tofal Payments: $34.48 Pavar Address Phorie D R Harton 134'! Horton Gircle Ariington TX 76d11 � Comments• - City af Zephyrhills Salid Waste Per i 19368 Address:6896 Silverado Ranch B! d. Parcel:05-26-21-QQ80-0070Q-002 While you wlll be paying your bill with Pa:co County Deve ment Serv s;the tult amouStaf the oredit card or e-check{�ys,NOT shown ahove,is tollected by First 91111ng payment servlces. MyReparts/reportstlPASGOPRQD/F'ASCO/ReceiptPOS V6.rpt 611 312 0 1 8 Page 1 af 1 �. . � I Ililll IIIII IIIII IIIII IIIII IIIII IIIII IIIII flill IIIII IIII IIII : ' . . 2018010491 Rcpt:1925414 Ree: 10.00 DS: 0.00 IT: 0.00 � , 01/19/2018 K. M. , Dpty Clerk Permit No. Parcel ID No �� l��Z�'(� ,(} �� ��f.�(�'ZQ NOTICE OF COMMENCEMENT ' , State of �/d r I (1 Q County of_ �QS Q THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 713,Florida Statutes, the following information is provided in this Notice of Commencement: 1. Description of Property: Parcel Identification No._[�� � �i[��IL���I I`J'P � (� Q)�° ���r ��' Street Address: �I'- l�d LC h � I S .F' ' 2. General Description of Improvement �� � � PAULA 5.0'NEIL,Ph D PRSCO CI.ERK & COMPTROLLI 3. Owner Information or Lessee information if the Lessee contracted for the improvement: 01/19/2018 02•46 m 1 of 1 � n OR BK C���� PG �C��� ��'o d.2. "�'Q I-P�r�M � r �v�t�/��'� �����'� _�L Address r C City�— State Interest in Property: _ '1�e e �1 i(�iQ �-Q Name•of Fee Simple Titleholder: ' (If different from Owner listed above) Address City 4. Contractor: _�• �. �I/*')�-�j/� ��� State ����ame -��Ie.�M �r OQ �� �� � IC� Address Ci Contractor's Telephone No.. State 5. Surety: _��►,—F- Name Address City Amount of Bond: $� `� State 7elephone No.. 6. Lender: /�, ��. , Name � Address • City � State Lender's Telephone No.: 7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)(7),Florida Statutes: � � 1e U i/►'� �-7 r�Cl� Nam� 1���O,� `�1���1 �/' � A dresa- s �— c� it State Telephone Number of Designated Person: — 8. In additlon to himself,the owner designates /�„� of � to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b), Florida Statutes. Telephone Number of Person or Entity Designated by Owner: 9. Expiratlon date of Notice of Commencement(the expiration date may not be before the completion of construction and final payment to the contractor,but will be one year from the date of recording unless a different date is specified): � WARNING TO OV1/NER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT , ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR�AN Ai-TORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalty ofperjury,I deciare that I have read the foregoing notice of commencement and that the facts stated therein are true to the best of my knowledge and belief. STATE OF FLORIDA COUNlY OF PASCO • Signa re o Owner or Lessee,or Owner's or Lessee's Authorized Office irector/Partner/Manager M—I�i�: ��l r'P�/��/ — '� '�7�`,�-C! rl� Signatory s Title/Office The foregoing instrument was acknowledge before me this�_day of��n r ,20 L,by �Q�C d� �'�p���Q�� as � � ����/ ✓ l , , JQ�.�n T,.a1� (type of authority,e.g.,officer,trustee,attorney in fact)for —k �� (name of pa on be alf of hom instrument was executed). Personally Known[�OR Produced Identitication❑ Notary Signature Type of Identificatfon Produced Name(Print) ' ' � , - � , � iP�°6e Nota � � �� �Y Public State o}F Mlchel►e Mo ro�da wpdata/bcs/noticecommencement pc05::r 48 MY Comm)ss�o nG � � °f n� Expire9 12/21/2020 057321 �1'/���+�r��L�K,'B�A, E:,y�4•J��f�'�s`�95��"�,d;� � �} � THIS IS TO CERTIFY T�A,T TH�F()���p(y�}�.��j� � - . o �a�„�y TRUE AND CORRECT C�PY OF TH�D��tJM�:i��f� �:� ORd.FILE OR OF PUBLIC R�C,QI�Q��Y�{i�!��Fl�� �y ; � ,��,��� `z ,�j WITNESS MY hIANC3 ANQ OFFIf�IAL���L 1'F�:a � ' " , � �,� �r `�' �� UAY OF ���'" •;���:• ,;,,. �, ��� � �r�' a�� � _ �'�. �"�` ;.�"� PAULA S. O'RlEIL, RK C�fVlF�i R�LLE€� i,�.:��� ..,�p, � � ,;;�� `�� -�' ���)�` '�#'�� BY ,��P�;i'Y C�FR;< �;'°�� _,.�. ` ' �� �� a �o� �,��,' `�y� � �• � 8'13-780-0020 City of Zephyrl�ilis Permit Application Fax-813-780-0021 • " Building Department Date"Receiv2d ' �; Tf-I1TfTT- Phone Conta�t for Permitting "1 �'�T r`�'�a�`a'��`� � � �`� °'��•���� r , Owner's Name � �.� ,. a � � Owner Phone Number / 1 � ^ � .�L[ L�. d. �� Owner's Address ���Q���I�e c=� ,r f�,.r 'TG��,�c j�� >•-�"-) ' . � � /Owner Phone Number • i Fee Simple Titleholder Name c ,.�. ,� I , Owner Phone Number Fee Simple Titleholder Address � JOB ADDRESS rjL��j ' �,`rC \ ` /� r . � `} ,`� • s � � I �� LOT# � SUBDfVISION �i�� L�•G�'� � / � PARCEL ID# �� ' "'r:��-���� J -(� ��`���� (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR ADD/ALT � SIGN ' � ��'INSTALL e REPAIR 0 0 DEMOLISH PROP05ED USE �� SFR � COMM �� OTHER TYPE OF CO.NSTRUCTION ��' BLOCK � FRAME � STEEL � • DESCRIPTIOIV OF WORK O��L� J�� 1�•�'��� � � � L' �Y''P L ��_�d� �, zr -� f ���:�z��:��a� i �����. BUILDING SIZE SQ FOOTAGE �pZ� Z •� Trrr�-r-u-�-r-r.-r-.�_ H E i G HT r-�-r-r-�-�-r-e�-rr-r-rr-r-e-s-�r-�--o--o--e-e-re-Q-r-r�-�--y-i-o--r�-��-0-9-�-e-e-v-ra-e-e-a'-�-o-i- �'13fJI,LDING � �� ;�� VALUATION OF TOTAL CONSTRUCTION Q.ELECTRICAL $ , , j��v AMP SERVICE � PROGRESS ENERGY � W R.E.0 ��UMBING � ' � Cl'U � [�"MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION v� � ,� , �� . � GAS 0 � ROOFING � SPECIALTY � OTHER • FINISHED FLOOR ELEVATIONS ` }�)`��� FLOOD ZONE AREA �YES NO l "p..'p-�a--0-F-0-�,-•�--�-I--F-�-C-�--i-7--C--i-C-6-�F-�--:--8--i--6-f-�--3-S-6-o--�-.i TP ■ �1 . � � y � y p � p � u f T��o� �11_ �I�ImYmL ri�T��� Y41� BUILDER •;� SIGNATURE � � - '� COMPANY :IJ� � .. �-� v ,_;.�_�•�,--� �"1,L� REGISTERED Y/ N FEE CURRE� _ Address �����,� %_/ Y/N �'<� .� .� r^ )c�i7�� c.. License# ���C�,��j C� f, ;� .�LECTRICIAN ��� SIGNATURE ��'`�"`-'� COMPANY ��,�'j`1,CJn�7,�,3'",p'„� ,���,��1^�, � • • REGISl'ERED Y/ N FEE CURRE� Y/N Address � 4�d.�yJQ�t��F'�,�"L� �,.,,,� � �f � License# ���,�������,� PLUMBER /� ,�/ / ,,�'+ SIGNATURE ����"� t�� — C�MPANY � f'" ���'"r��,(�,�` •.��,�•G"s�,�.3'.L-,�� F"��,rJ��r�7��'a � REGISTERED Y/ N FEE CURRE� Y/N Address �����(� '"�� � � � `"�'��� � License# ��k�� �F;/r� �� MECHANICAL � SIGNA7lIRE �"a"��:,'_-..-=-C.��,m�-�_____ COMPANY �A`�1�(',i�/`��,fl,j-G��,��' �d�- ,�:� ,�7�e�'.�.Jl" �REGISTERED Y�`/ N FEE CURRE� Y/N Address ���7� �F.-�.-„��,,, � _ �C'� f���,.�f^�,•�,C'J`�:.,��j- , License# ��������� OTHEFi ' .,r SIGNATURE � ' �rR'- -�-- --�--�—' COMPANY � f �i /� - -�/�-. .. �, f jA Y�.l,N,�1�j-../�'ri/1�/�i� :�-��(��-��ra-� I p �^-� FEE CURRE� Y/N �" R EG I STERED Address F ���/'!--.3 ,� �1�� � ���. �.: � 1 1 L 1 1 1 1 1 1 1 1 1 1 i I 1 1 1 1 1 7 1 1 1 p 1 1 1 1 1 7 L 1 1 1 L L 0 1 1 6 1 I 1 1 1 IIC7 059 0 p 0 Q 0 0 � B � � 6 a � � B � � RESIDENTIAL Attach (2) Plot Plans; (2)sets of Buildfng Plans; (1)set of Energy Forms; R-O-W Permit.for new construction, Minimum ten (10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Siit Fence installed, Sanitary Facflities &1 dumpster;5ite Work Permit for subdivisions/large proJects COMMERCIAL Attach (2) complete sefs of Building Plans plus a Life Safety Page; (1)set of Energy Forms. R-O-W Permit for new constructlon. Minimum ten (1 D)workfng days after submittal date. Required onsite,Construct(on Plans,Stormwater Plans w/Silt Fence fnstalled, 5an(tary Facllities &1 dumpster.51te Vliork Permit for all new projects All commercial requirements must meet compliance SIGN PERMIT Attach (2)sets of Engineered Pians. *"**PROPERZY�SURVEY required for all NEW constructlon. IDirecYfons: , FII�I out aPplication�com�te��_�_�-�����e...¢-�B...g-d-.g-�--�g-�4"'�"��-�-�-�&-�e�A�p��=-a-8-�..6_b�. Owner�Contractor sfgn back of appifcation,notarized IP over$2500,a Notice of Commencement is required. (A/C upgrades over$7500) "` Agent(for the contractor) or Power of Attorney(for the owner)would be someone with notarized letter from owner aLthorizing same t �VER THE COUNTER PEFiMITTING �eroofs if shingles Sewers �, �COPy of contract requfred) � , ,ervice Upgrades A/C Fences (Plot/Survey/Footage) - . Driveways-Not over Counter if on�ublic roadways.rieeds ROW � . � - � , ` � � . �OTi�� OF D���3 RE�TRi�T3Qt�5- The undersigned understands that this permit may be subject to °deed" restrictions". which may be mare restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions IDPILICEiVS�D CON'T'�tACTORS A1VD COIUTRAG7CIR RESPQNSlBtLITfES: if the awner has hired a contractor ar contractars to undertake work, they may be required to be licensed in accordance with state and foca! regulations. (f the contractar is not licensed as required by law, both the owner and cantractor may be cited for a misdemeanor vialatian under state (aw. if tha owner or intended contractor are uncertain as ta what licensing requirements may apply for the intended work, they are advised ta contact the Pasco County Building (nspectian Division—Licensing Sectlon at 727-847- � � 80Q9. Furthermore, if the owner has hired a contractor or contractors, he is advised ta have the contractar(s} sign portions of the "contractor Block" of fhis application far whicn they wil! be responsil�le. If yau, as the owner sign as the contractor, that may be an indication that he is not praperly licensed and is not entitled to permitting privileges�in Pasca County. TRANSPORTATtOE� [tt�PACTjUT1LfiTtES 1MPACT AND AESOURCE RECOVERY FEES: The undersigned.understands that Transpartation lmpact Fees and Recourse Ftecovery Fees may apply to the construction af new buildings, change of use in existing buildings, or expansion of existing buiSdings, as specified in Pasca County Ordinance number 89-d7 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, wi!! be id�ntified at the time of � permitting. It is further understaod that Transpartation Impact Fees and Resource Flecovery Fees must be paid prior ta � receiving a "cerEificate af occupancy" or final power release. If the project does not involve a certificate ofi occupancy or , final pawer release, the fess must be paid prior ta permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due,they m�st be paid priarto permit issuance in accordance with appiicable Pasca County ordin�rrces. , ClJAlSTk�UCTIl�N �lE�§ LAW {Chapter 713, Florida Statutes, as amended): lf valuation af vuork is $2,500.00 or more, f certify that I, the applicant, have be�n pravided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someane , ofher than the "owner", i cerEify fhat I have obtained a copy of the above described dacument antl promise in goad falth ta , deliver it to fihe'"owne�" prior to commencement. , � CON7RACTOR'S10lNIUER'S AFFiDAVlT. ! certi#y that ali the information in this appiication is accurate and that a(i work ' wil! be done in campliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. f certify that no work ar insta!lation has 'p commenced prior to issuance ofi a permit and that all work wil( be performed to meet standards of all laws cegulating construction, County and City codes, zoning regulations, and land deveiapment regulations in the jurisdiction. 1 also certify that i understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identifiy what actions ! must take ta be in compiiance. Such agencies include but are not limited ta: - Department of Environmental Pratection-Gypress Bayheads, Wetland Areas and Environmentafly Sensitive Lands, Water/Wastewater Treatment. - Sauthwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering � Watercaurses. . - Army Corps af Engineers-SeawaNs, Docks, Navigabia Waterways. ' � - Department of Health & Rehabilitative Services/Cnviranmental F{ealth Unit-Welfs, Wasfiewater Treatment, f Septic Tanks. , - US�Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. i understand that the followtng restrietions apply to the use a#fill: - Use of fi!! is not allowed in Flood Zane "V" unless expressiy permitted. - lf the fill materiai is to be used in Flood Zone "A", it is understood that a drainage .plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State ofi Florida. - If the fii( material is ta be used in Fiood Zone "A" in connection with a permitted building using stem wal( constructlon, S certify that fiil wiil be used aniy to fill the area within the stem wal{ - If fill materia{ is to be used in any area, I certify that use of such fiii wifl not adverseEy affect adjacent properties. If use of fi(I is found to adversely aifect adjacent properties, the owner may be cited for vioiatirtg � ` the conditions of the building permit issued under the attached permit application, for lots less than one (1} acre which are e(evated by fili, an engineered drainage plan is required. . � 1f I am the AC�Rl�' F�1R TH� �1Nh�ER, 1 pramise in good faith to infarm the owner af the permit�ing canditions set forth in this affidavit prior ta cammencing construction. i understand that a separate permit may be.required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specificaliy inciuded in the appiication. A � permit issued shall be construed to be a license ta proceed with•the work and not as authority to violate, cancel, alter, or i set aside any provisions af the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a carrection of errars in plans, constructian ar vioiations of any codes. Every permit issued shall become invalid � unless the work autharized by such permit is cammenced within six monfihs af permit issuance, ar if wark authorized by � the permit is suspended or abandoned for a period,.a�six (6) months after the time the v�'roric is commenced. An extension I may be requested, in writing, from the Building C7fficial for a period not ta exceed ninety (90) days and wi(1 demonstrate � ` justifiable cause for the extension, If work ceases for ninety (90) consecutive days,the job is considered abandonecl. I I WARNE�IC �'C� ��IV�1�E3: VOUR IFAIL:URE TQ RECORD A NUTICE OF Cf3MMENCEMENT MAY RESULT 1N YOUR PAYlNG TWlC� FC}R tMPROV�.MENTS T(�YtJUR PROPERTY. 1F VOU INTEND TO OSTAIN FtNANC1tVG, CONSULT W1TH YOUR LENDER OR AN A7TORNEY BEFORE ftECORb1NG YCJUR NdTtCE OF COMMENCEM�NT. FLORIDA JURAT(F.S 117.03) � � OWNER OR AGENT � ���–P"'—'"" CONTRAGTdR Sub cribed and sw4i�n ta (or afflrmed)before me this Subscribed and sworn to(or affirmed) before me thls 41 by .1��.1-�n•n•����tz.a.�.�e-,�-�5.--....� by . Vi/ho is aU�kae�ara-Yar.n�.,Qr has/haveproduced , Who is(are persflnally known ta me or haslhave produced as identification. as fdentlficatlon. r � � � �l � � ` J �=�"r ' ,.-- Notary Rublic Notary publlc ' Cammission No t„�, (�� � Commfsslon No. ''�` Name of N t y ty > r' e t i Name of Notary typed,printed or stamped =o��,� Notery PuDlic 5tata of Fiorida � . iUiiche!!e MoyBs _ � ��rr My Commisefan GG 057321 oF�v' �XPftes 12l21J2820 , D.R. Horton-6896 Silverado Ranch Blvd:2,362 sq ft o umn SQ. FEET PRICE MAIN OR LIVING: 2,362 $ 112.65 OTHER AREA UNDER ROOF: - $. 88.00 OTHER: - $ - VALUATION $ 266,079.30 FEE SHEET $ 989.00 ADDRESS $ 40.00 DRIVEWAY $ 40.00 BUILDING: $ 1,088.78 ELECTRICAL: $ 222.53 PLUMBING: $ 148.35 MECHANICAL: $ 103.85 SUB-TOTAL $ 1,563.50 TOTAL $ 1,563.50 SEW ER: n/a WATER: n!a ' IRRIGATION: $ � - , TOTAL: $ - WATER METER: n/a IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 � 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 2,116.85 PARK IMPACT FEES $ 769.56 �� SIF'S: $ 4,828.00 ' 100.0% $ 4,828.00 1.0% $ 48.28 TOTAL: $ 4,876.28 i T I F'S : 3 632.00 $ , 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 11,394.69 Single Family Dwelling Plan Review Comments 1. F.F.E. shall be a minimum of 8" above the road elevation and an engineered site plan. 2. Lots shall be graded to comply with R401.3 of the F.B.C. 3. Compaction test required if 24" or more of fill dirt is brought in at any one place. 4. Tie in survey required before pouring concrete. 5. Driveways require a R.O.W. use permit. A114 sides of driveway thru the sidewalk shall have expansion material. 6. All setbacks shall be met. 7. All property markers shall be uncovered and marked at time of first inspection. 8. All A.D.A. requirements shall be met. 9. No electric,plumbing, mechanical, or framing shall be covered without an inspection and approval first. 10. All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation). 11. Appliances shall not be installed in a location where subject to mechanical damage unless protected by approved barriers. M303.4 of the F.B.0 12. Water heaters shall comply with section P607.3 of the F.B.C. 13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M1308.1 14. Return air in all bedrooms. F.B.C. M1620.4 15. Smoke detectors are to be installed in accordance with R313.1 of the F.B.C. 16. All glazing requirements are to be in accordance with R308.4 of the F.B.C. 17. All means of egress are to be in accordance with R311 of the F.B.C. 18. "Green gypsum board" shall not be used as a backer in showers or tubs. R702.4.2 F.B.C. 19. Combination-t e AFCI breakers are re uired at all locations re uirin an AFCI t e breaker. YP q q g YP 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating or appliances or an attached garage. They shall be installed in accordance with the F.B.C. 21. All plumbing, mechanical, and electrical shall be separate from unit to unit. This includes all underground plumbing and electric. 22. A112008 N.E.C. Codes will be enforced. 23. Tamper-Resistant Receptacles in accordance with 406.11 of the 2008 N.E.0 24. In accordance with the Land Development Code, lots shall be sodded before final at least 10 feet around the structure. 25.A copv of the energv cacls shall be with permit at all times. 26. Copy of final insulation renort shall be nrovided with nermit before �na� F.F.E.-Finished Floor Elevation F.B.C- Florida Building Code 5�'Edition R.O.W.-Right of Way A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2008) PLOT PLAN � DESCRIPTION:(AS FURNISHED) ' LOT 2, BLOCK 7 SILVERADO RANCH SUBDIVISION PHASE 6, 8 & 9A NOT YE7 RECORDED IN PLAT BOOK ----, PAGE(S) ----, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. Curve Table Curve �J Length Radius �Delta Chord Bearing Chord � C7 58.71' 2060.00' 1'36'S8' N79'45'S9�W 58.10' C2 54.58' 1935.00' 1'36'58' S19'45'S9'E 54.58' C3 139.33'• 2100.00' 3'46'OS' S1737'37'E 139.30' � C4 118.46' 2100.00' 3'13�55� 517'20'32'E 118.44' a CS 20.87' 2100.OD' 0'34'10� S19'14'35'E 20.87' � � o \z i" = 3o' � GRAPHIC SCALE 0 15 30 \ �� L�� �� '�96 � Z� GK y''��'s� 6L� + m° ���, 125�� ^ �2�' UNpPRY .� / /42� �� � ' / PIP`pS g0 \ `Rpp\P�-'�PR\N�� / •,pi � � O GE O � Z.0 ' � N �R���02 3 � � � N � _ N� � � 90� � � � � P�� 5g;i� a� 9 w O �� — - - \r �� �3�j �9 6� � �o � N \ S��•07.0�W� � \\25 \ c^-9 �-o Q, �H�� ��O c�\ AO�� 2. . .">\ �^Zr P � ci � S �, � ,• o yb'myG�o B� . 'O ,C . �...��:o ..�`?'`\wZ�°'c`� oyo�m°n�„ �o... a2e \ ��c��y� "'�1,?%`,.�-�"� <?� N O / �O i , EZRA LOFT /'/ , _ _.,.;�.�.. � ,• 4�o N o�� �o��`:. i � �a x�<�in� PLACE • _: ':::: ,. .5.... .w,� �� �' � ��'2 � ��, �• .. •�. ' .•w � � i •N 0 .�.c o TRAC7 "�" -• - 6 : / 12�Q \ y 60' RIGH7 OF WAY :`m.;.� ,.22� ' a�� 5�1 � �„ �Z (PRIVA7E ROADWA17�p1 "-iri� � 226 > / \ ,r� � ,`4 � o \\ �� � CENTERLINE OF j � RI6HT—OF—Wqy ` � � �\ ` / / 2 � �� 2\ �/ 569 R°`3 1 r��� \ - ,,88 �p� � �p � ; `0 5 ''8 g��G� '��� � � 4s ON LOT CALCULATIONS -`�2 �� , • LOT = 7,043 SQ. FT. ��•C� c+``�2 -o \ LIVING AREA = 1,828 SQ. FT. ���y � y-�p o,jDoo � GARAGE = 430 SQ. FT. a�y�� ��y ,�oN ENTRY = 16 SQ. FT. 9.coG �0 6a L'ANAI = 88 SQ. FT. O � -��^� <^` �y PA110 = 0 SQ. FT. �z�L ��� DRIVEWAY = 529 SQ. FT. 9,c y � 9� A/C PAD = 12 Sp. FT. Q \ � WALKWAY = 28 SQ. FT. IMPERVIOUS = 42% = 2931 SQ. FT. SOD = 4,112 SQ. FT PREPARED FOR: oFF�oTcn�cuwT�oNs �y R� �, RIGHT OF WAY = 1536 SQ. FT. !)'R'H����1�� vf�,. DRIVE APRON = 133 SQ. FT. '/l�GMfGG�:=,�-'��if�'��' PUBLIC 5/W = 468 SQ. FT. SOD = 935 SQ. FT. TOTALS BUILDING SETBACKS AREA = 8,s�s S0. FT. FRONT: 22' DRIVEWAY = 662 SQ. FT. REAR: 15� SIDEWALK = 496 SQ. FT. SIDE: 7.5� SOD = 5,047 SQ. FT. SIDE STREET: 20' LEGEND: NOTES. — — — BUILDING SETBACK LINE PI POINT OF INTERSECTION PC POINT OF CURVATURE 1. ELEVA710NS SHOWN ARE PER LOT GRADING - - - CENTErtuNE p7 POINT OF TANGENCY PLANS PROVIDED BY THE CLIENT. - - - - RicHT oF wnv uNE RP RA�IUS POINT 2. ELEVATIONS ARE BASED ON NAVD 1988 XX PRC POINT OF REVERSE CURVATURE DATUM. � PROPOSED ELEVATION PCC POINT OF COMPOUND CURVATURE TYP TPICAL � PROPOSED DRAINAGE FLOW CS CONCRETE SLAB THIS PLOT PLAN IS INTENDED FOR PERMITTING PURPOSES � (P) PER PLAT , ONLY. THIS IS NOT INTENDED FOR THE CONSTRUCTION OF CONCRE7E ��� CALCULA7ED THE PROPOSED HOUSE. REFER TO HOUSE PLAN AND A/C AIR CONDI7loNER PB PLAT BoOK OPTION LIST FOR CONSTRUC110N. ALL BUILDING SET BACK S/W SIDEWnLK PGS PpGEs SQ. FT. SQUARE FEET LINES SHOWN HEREON IS PER DATA FURNISHED BY CLIENT F.E.M.A. FEDERAL EMERGENCY AIANAGEMENT AGENCY AND IS FOR INFORMATIONAL PURPOSES ONLY. F.I.R.M. FLooD INSURaNCE RA�MnP, NAVD NORTH AMERICAN VERTICAL DATUM THIS IS NOT A SURVEY NGVD NA710NAL GEODETIC VERTICAL DANM D&UE DRAINAGE& UTILITY EASEIAENT THIS IS A PLOT PLAN ONLY PDE PRIVATE DRAINAGE EASEMENi UE UTILJTY EASEMENT(PUBLIC) FLOOD NOTE: � SURVEYOR NOTES: I HAVE EXAMINED THE F.I.R.M. b1AP N0. 121D1CO268F, 1. THE SURVEYOR HAS NOT ABSTRACTED THE DATED SEPTEMBER 26, 2oia, AND FOUND THE SUBJECT PROPERTY LAND SHOwN HEREON FOR EASEMENTS, RIGHT APPEARS TO LIE IN ZONE 'X', AREAS DETERIAINED TO BE OU751DE THE OF WAY, RESTRICTIONS OF RECORD WHICH 0.2%ANNUAL CHANCE FLOODPLAIN. THE SURVEYOR IAAKES NO MAY AFFECT 7HE 7ITLE OR USE OF THE LAND. GUARANTEES AS TO THE ABOVE INFORMATION. PLEASE CONTACT THE LOCAL F.E.�.n. aGEN7 FOR vERiFlCAnoN. 2. NO UNDERGROUND IMPROVEMENTS HAVE BEEN BEARING BASIS: LOCATED EXCEPT AS SHOWN. BEARINGS SHOWN HEREON ARE BASED ON THE NORTHERLY LINE OF 3. NOT VALID WITHOUT THE AUTHENTIC � LOT 2, BLOCK 7 BEING N71'02'30'E, PER PLA7. ELECTRONIC SIGNATURE AND THE AUTHENTIC A M E R 1 CA N ELECTRONIC SEAL OF A FLORIDA LICENSED (FIELDDATE:j REVISED: SURVEYOR AND MAPPER. SU RV EY 1 N G ,o�'�ca DigitallysignedbyJamesW 1'= 30 FEET �- ���!."'r �� . Boleman SCALE: � M A P P I N G 1 N C. `�:• 'DN:cn=James W Boleman, ���•��� � o=American5urve in &Ma g APPROVEDBY• �B ����' :���`'ou Y 9 ppin, CERTIFlCATION OF AUTHORIZATION NUMBER LB�6393 �5;:,,"n`,,:�"`:'o� ,,.email-'boleman@asmcor te.co FOR 3191 MAGUIRE BOULEVARD, SUITE 200 ' •••''+°'� m,c=u5� , Pora TME .lOBNO. »�013 LOT 2, BLK 7 ORLANDO, FLORIDA 32803 �°"`""••• ' Date:2o77.103710:183o-04'00' FlRU � (407) 426-7979 DATE DRAWNsv: DSB pLOT PLAN 70-25-2017 JML-- - �'�•AMERICANSURVEYINGANDMAPPING.COM JAMES W. BOLEMAN PSM# 6485 � � FORM R405-2014 � FLORIDA ENERGY EFFtCtENCY CODE FC7R BUtLDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Perfarmance Methad Project Name: Ca(i ElevaEion + Builder Plame: I}RH Express Hames / Street: - C����1� ����f�'.r�(i t��.(dt[����J'(�,�„ PermitQffice: ,1(��,� ��i.ct�rC(S Gity,Siate,Zip: ZephyrhiJ!'s,F!.,�j��� � Permit Number: 1 t� 3 �► Owner: � Jurisdiction: � G�� - Design Location: FL.,Tampa c�r County:: Pasco(Florid�limate Zone 2) 1. New construction or existing New(Fram Plans) 9. Wall Types(1710.2 sqft.) Insulation Area 2, Single family or multiple family Single-Eamily a.Cancrete Biock-Int Insul,Exterior R=4.1 1404.00 ft2 b. Frame-Waod,Adjacenf R=11.0 306.22 ft2 3, Number of units,if multiple family 1 c. N/A R= ft2 4. Rlumber of Bedroams 4 d.NIA R= ft2 10.Ceiling Types (1828.0 sqft.) Insulation Area 5, Is this a worst case? No a.Under Attic(Vented) R=30.0 1828.00 ft2 6. Gonditioned tlaar area above grade(ft2) 1828 b.NJA R= ft2 Conditioned floor area below grade(ft�) 0 c.N/A R= ftz 11.Ducts R ftz 7. Windows{186.5 sqft.) description Area a.Sup:Afiic,F?et:Main,AH:Main 6 356 a. U-Factor: Dbl,U=0.34 126.50 ftx SNGG• SHGC=Q.31 b. 11-Factor. Dbl,U=0.55 4�.dd it2 j2•Cfla�in9 systems k8tulhr Efficiency SHGC• SHGC=0.34 a.Central Unit 28.6 SEER:14.00 c. U-Factar: NIA ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Neat Pump �8.6 HSPF:8.20 SI-IGG: Area Weighted Average Overhang Depth: 2.722 ft. Area Weigh2ed Average SNGG: 0.3i7 14.Hot water systems a.Electric Cap:5d gallons 8. Floor Types (1828.0 sqft.) Insulation Area EF:0.950 a.Slab-On-Grade Edge lnsulation R=0.0 1828.00 ft2 b. Conservation feafures b.NIA R= ft2 None c.N/A R= ft2 15,Credits Pstat Total Propos�ed Modified Loads: 60.55 pASs Glass/Floor Area: 0.091 Tata! Baseline Loads: 61.25 i hereby certify thai the plans and specificatians covered by Review of the plans and �'��$T.q�. fhis caicu(ation are in compliance with the Fiorida Energy � specifications covered by this ��� '" _ -�'�p Code. calculatian indicates compliance '`�'�i,�'''� '�=;:"`�,�'� � with the Flarida Energy Code. ti rr,rrr:'�,�'i�%-`r;='�::'';:;�t,'�O ..,�,. .._. PREPARED BY: _��k.�Q•�.�-+ " Before canstruction is completed v� ;_� ' � :t<<_-..... DATE: �o-�l►-i7 this building wiH be inspected for � ""'� � comp(iance wifh Section 553.908 * ° - ° � 1 hereby certify that this building,as designed,is in compliance Florida Statutes. � A �.S with the Florida Energy Code. . ��D y1�E'�`� OWNER/AGENT�` � �', -�'' � BUlLDING OFFI lAL: DATE: ���� l�i�_� DA�'E: - CompEiance requires certiflcation by the air handler unit manufacturer that t[�air handler enclasure qua[ifies as certified factory-sealed in accordance with R4q3.2.2:1. , -Compliance requires an Air Barrier and Insulatian Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in acc4�'dance with R402.4.1.2. - Compliance with a proposed duct leakage�n requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with Section 8Q3 of RESNET Standards,is not greater than 0.064 Qn for whole hause. 10/30/2017 11:18 AM EnergyGaugeC�USA-FlaRes2014 Section R408.4.1 Compliant Saftware Page 1 of 4 � -- ; � ' FORM R405-2014 ' . FLORIDA EfVERGY EFFICIENCY CODE �'OF� BUILDING CO�VSTRUCT'lON Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Cali Elevation r Builder Name: DRH Express Homes Street: - C��-j� S���JZr�,(� `i�(v�r���V��{ Permit Office: City,State,Zip: Zephyrhi(ls, FL,33�� .� Permit Number: Owner: �} � Jurisdiction: Design Location: FL,Tampa �Lr County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1710.2 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul, Exterior R=4.1 1404.00 ftz b.Frame-Wood,Adjacent R=11.0 306.22 ftz 3. Number of units,if multiple family 1 c.N/A - R= ftZ d.N/A � 4. Number of Bedrooms 4 R=' ftz 10.Ceiling Types (1828.0 sqft.) Insulation Area � 5. Is this a worst case? , No a.Under Attic(Vented) R=30.0 1828.00 ft2 6. Conditioned floor area above grade(ftz) 1828 b.N/A R= ftz Conditioned floor area below grade(ftz) 0 c. N/A R= ftz 11.Ducts R ftz 7. Windows(166.5 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 356 a. U-Factor: Dbl, U=0.34 126.50 ftz SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.55 . 40.00 ftz 12•Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.34 a.Central Unit 28.6 SEER:14.00 c. U-Factor: . N/A ft2 'I SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 28.6 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 2.722 ft. Area Weighted Average SHGC: 0.317 14.Hot water systems 8, Floor Types (1828.0 sqft.) Insulation Area a.Electric Cap:50 gallons a.Slab-On-Grade Ed e Insulation R=0.0 1828.00 ftz EF:0.950 9 b. Conservation features b.N/A R= ft2 � None c.N/A R= ftz 15.Credits Pstat Total Proposed Modified Loads: 60.55 n A�� , Glass/Floor Area: 0.091 Total Baseline Loads: 61.25 rH I hereby certify that the plans and specifications covered by Review of the plans and �.��,HES�?,� • this calculation are in compliance with the Florida Energy - specifications covered by this = � O '/��� Y��1� Code. calculation indicates compliance � �,,, -_„��� K+ with the Florida Energy Code. ti rr,;F:.,�%�;".::,='�:•0,• `�i,'rp f':;,,.-:.. PREPARED BY: �'P�1�-�-,..�-. - Before construction is completed r� f ' '�" " � DATE: io-3o-r� this building will be inspected for � ��!'�```' ,g,� compliance with Section 553.908 * �.m , ,� I hereby certify that this building, as designed,is in compliance Florida Statutes. - ,� �,S with the Florida Energy Code. �ptj -�'� / i�V� OWNER/AGENT�`��'� !1�f�a'+/� � BUILDING OFFICI, : ` DATE: �I �� ���1i�� �� DATE: - �/ . � � , � r. _ . - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2:1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance w�+th Section 803 of RESNET Standards, is not greater than 0.060 Qn for whofe house. 1 0/30/2017 1 1:18 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 � ' � �FORM.R405-2014 PROJECT Title. CalipElevation D Bedrooms: 4 Address Type: .. .,.Lot Information Building Type: User Conditioned Area: 1828 Lot# 2/7 Owner Total Stories: 1 BIocWSubDivision: Silverado Ranch #of Units: 1 Worst Case: No PlatBook: - Builder Name: DRH Express Homes Rotate Angle: 270 Street: Permit Office: Cross Ventilation: County: Pasco Jurisdiction: Whole House Fan: City,•State,Zip: Zephyrhills, Family Type: Single-family FL, New/Existing: New(From Plans) Comment: Garage L Face W . " � � CLIMATE ' / IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Tampa FL_TAMPA_INTERNATI 2 39 91 70 75 645.5 54 Medium BLOCKS Number Name Area Volume 1 Blocki 1828 15848.8 SPACES , Number Name Area Volume Kitchen Occupants Bedrooms InfiIID Finished Cooled Heated 1 Main 1828 15848.8 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet j 1 Slab-On-Grade Edge Insulatio Main 198.6 ft 0 1828 ftz ____ 0 0'25 0.75 ' ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul, (deg) 1 Hip Composition shingles 2044 ftz 0 ftz Dark 0.92 No 0.9 No 0 26.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 1828 ftz Y N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) Main 30 Blown 1828 ft2 0.11 Wood 10/30/2017 11:18 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software - Page 2 of 4 J l .FORM.R405-2014 WALLS Adjacent Space Cavity Width Height _ Sheathing Framing Solar Below 0 _ 1 N=>W Exterior Concrete Block-Int Insul Main 4.0999 19 8 8 164.7 ftz 0 0.6 0 _2 E=>N Exterior Concrete Block-Int Insul Main 4.0999 43 8 8 8 ,378.4 ftz 0 0.6 0 _3 S=>E Exte�ior Concrete Block-Int Insul Main 4.0999 39 S 8 8 343.8 ftz 0 0.6 0 _4 W=>S Exterior Concrete Block-Int Insul Main 4.0999 59 8 8 8 517.1 ftz 0 0.6 0 _5 N=>W Garage Frame-Wood Main 11 20 0 8 8 173.3 ftz 0.23 0.01 0 _ 6 E=>N Garage Frame-Wood Main 11 15 4 8 8 132.9 ftz 0.23 0.01 0 _ DOORS � # Ornt DoorType Space Storms U-Value Width Height Area Ft In Ft In 1 N=>W Insulated Main None .4 3 6 8 20 ftz 2 N=>W Wood Main None .46 2 8 6 8 17.8 ftz WINDOWS Orientation shown is the entered orientation => chan ed to As Built rotated 270 de rees . � / Wall ' Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Area- Depth Separation Int Shade Screening 1 N=>W 1 Vinyl Low-E Double Yes 0.34 0.31 31.0 ftz 1 ft 0 in 4 ft 1 in Drapes/blinds Exterior 5 2 N=>W, 1 Vinyl Low-E Double Yes 0.34 0.31 2.5 ftz 3 ft 8 in 0 ft 0 in Drapeslblinds Exterior 5 3 E=>N 2 Vinyl Low-E Double Yes 0.34 0.31 15.5 ftz 1 ft 0 in 0 ft 9 in Drapes/blinds Exterior 5 4 S=>E 3 Vinyl Low-E Double Yes 0.34 0.31 62.0 ftz 1 ft 0 in 0 ft 9 in Drapeslblinds Exterior 5 5 S=>E 3 Metal Low-E Double Yes 0.55 0.34 40.0 ftz 8 ft 0 in 0 ft S in , Drapes/blinds Exterior 5 6 W=>S 4 Vinyl Low-E Double Yes 0.34 0.31 15.5 ft2 1 ft 0 in 0 ft 9 in Drapes/blinds Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 430.0128 ft2 430.0128 ftz 46.6 ft 8.67 ft 0 INFILTRATION # Scope Method SLA CFM 50 ELA EqLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000386 1849 101.51 190.9 .2892 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 �lectric Heat Pump None HSPF:8.2 28.6 kBtu/hr 1 sys#1 10/30/2017 11:18 AM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliartf Software Page 3 of 4 1 FORM R405-2014 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit None SEER:14 28.6 kBtu/hr 858 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation " 1 Electric �None Garage 0.95 50 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None Nane ftz - DUCTS / ----Supply---- ----Retum---- Air CFM 25 CFM25 HVAC# \/ # Location R-Value Area Location Area Leakage Type Handler TOT OUT oN RLF Heat Cool 1 Attic 6 356 ftz Main 40 ftz Proposed Qn Main ---cfm 109.7 cfm 0.06 0.60 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Coolin Jan Feb Mar r lA r Ma Jun Jul Au Se Oct Nov Dec Heating Jan f X}Feb �Mar [ ]APr f �May f�Jun 4�Jul 4�Au9 f�SeP E�Oct �Nov �Dec Ventin Jan [ ]Feb Mar [X]A r � Ma � Jun [ Jul [ Au [ Se [X]Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours ' Schedule Type 1 2 3 4 5 6 7 S 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 SO SO 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 , 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 � 66 66 ' Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 � 68 68 68 68 66 66 i 1 0/30/2017 1 1�18 AM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 4 , • FORM R405-2014 - ENERGY PERFOR,tVIANCE LEVEL (EPL) ` y DISPLAY CARD �� ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the EnergyPerformance Index,the more efficient the home. , Zephyrhills, FL, 1. New construction o'r existing New{From Plans) 9. Wall Types � Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1404.00 ftz I � b.Frame-Wood,Adjacent R=11.0 306.22 ft2 3. Number of units,if multiple family 1 c.N/A - z _ R- ft 4. Number of Bedrooms 4 d.N/A R= ftz 10.Ceiling Types Insulation Area 5. Is this a worst case? No a.Under Attic(Vented) R=30.0 1828.00 ftz 6. Conditioned floor area(ftz) 1828 b.N/A R= ftz z 7. Windows" Description Area 11 cDucts R R ftz a. U-Factor: Dbl,U=0.34 126.50 ftz a.Sup:Attic,Ret:Main,AH:Main 6 356 SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.55 40.00 ftz SHGC: SHGC=0.34 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ftz a.Central Unit 28.6 SEER:14.00 SHGC: . d. U-Factor: N/A ftz 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 28.6 HSPF:8.20 Area Weighted Average Overhang Depth: 2.722 ft._ Area Weighted Average SHGC:- 0.317 � 8. Floor Types Insulation Area 14.Hot water systems z a.Electric Cap:50 gallons a.Slab-On-Grade Edge Insulation R=0.0 1828.00 ft EF:0.95 ' b.N/A R= ft2 b. Conservation features c.N/A R= ft2 . None , 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building �gE ST Construction through the above energy saving features which will be installed (or exceeded) w0� _ �T�o in this home before final inspection. Otherwise, a new EPL Display Card will be completed ��cr�`,,,;'°f; :',:�,,. � based on installed Code compliant features. �,,,,��„;;:;;„�;:•,,,,�`„ o � � � g � � a l�/�/1 �- . z'i'' ... Builder Si nature: � x Date: � � ����`� : ' a� c G` - ( � � , �C,�'1 �,�- Address of New Home: ' ,� ,, , City/FL Zip: ; �, .� �; �S ��� �G S��b�.b. ��� �kt��� �// � �� � � o��.� . � �� c � � ��� �� � � , 'Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient �, , mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) ' 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters.' For � , information about the Florida Building Code, Energy Conservation, contact the"Florida Building Commission's support � staff. � **Label required by Section R303.1.3 of tlie Florida Building Code, Energy Conservation, if not DEFAULT. 10/30/2017 11:18 AM EnergyGauge�USA-FlaRes20]4 -Section R405.4.1 Compliant Software Page 1 of 1 �I FORM R405-2014 ''i � ' � Florida Department of Business and Professional Regulations Residential Whole Buildin Performance and Prescri tive Methods ADDRESS: Permit Number: Zephyrhills,FL, MANDATORY REQUIREMENTS See individual code sections for full details. � 401.3 Energy Peiformance Level(EPL)display card(Mandatory). The building official shall require that an eriergy performance level(EPL)- display card be completeii and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law [Section 553.9085, Florida Statues]requires the EPL display card to be included as an addendum to each sales contract for both'presold and nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix C. � R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to lirriit air leakage in accordance with the requirements of Sections R402.1 through R402.4.4. ' Q R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.The sealing methods between dissimilar materials shall allow for differential expansion and contraction. - • R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.i shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table 402.4 1.1,as applicable to the method of construction. Where required by the code official,an approved third party shall inspect all components and verify compliance. • R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2,and 3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. `During testing� 1.Exterior windows and doors,fireplace and stove doors stiall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3.Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5�Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. O R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers and outdoor combustion air. O R402.4.3 Fenestration air leakage.Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400 or AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer Exception: Site-built windows,skylights and doors. O R402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential.All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. � R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. � R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. � R403.2.2 Sealing(Mandatory)All ducts,air handlers,and filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post-construction or rough-in testing below. Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either an energy rater certified in accordance with Section 553.99,Florida Statutes,or as authorized by Florida Statutes,to be"substantially leak free"by either of the followi�g: 1. Post-construction test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure.All - register boots shall be taped or othervvise sealed during the test. _ 2. Rough-in test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25Pa)across the system,including the manufacturer's air handler enclosure.All registers shall be taped or otherwise sealed during the test.If the air handler is not installed at the time of the test,total leakage shall be less than or equal to 3 cfm (85 Umin)per 100 square feet(9.29 m2)of conditioned floor area. Exceptions: 1. The total leakage test is not required for ducts and air handlers located entirely within the building envelope. �2. Duct testing is not mandatory for buildings complying by Section R405 of this code. 10/30/2017 11:18 AM EnergyGaugeC�USA-FlaRes2014 -Section R405.4.1 Com Page 1 of 3 • FORM R405=2014 MANDATORY REQUIREMENTS - (Continued) � R403.2.3 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. ❑ R403.3 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C) or below 55°F(13°C)shall be insulated to a minimum of R-3., _ R403.3.1 Protection of piping insulation. � R403.4.1 Circulating hot water systems(Mandatory). Circulating hot water systems shall be provided with an automatic or readily �, accessible manual switch that can turn off the hot-water circulating pump when the system is not in use. � R403.4.3 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a - downward and upward bend of at least 3�/z inches(89 mm)in the hot water distribution line and coid water line located as close as possible to the storage tank. � R403.4.4 Water heater efficiencies(Mandatory). 0 R403.4.4.1 Storage water heater temperature controls . R403.4.4.7.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature setting range shall be from 100°F to 140°F(38°C to 60°C). . R403.4.4.y.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s) of combustion types of service water heating systems to be turned off. � R403.4.4.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water heating category. Solar water heaters shall met the criteria 5ection R403.4 4.2.1. . R403.4.4.2.1 Solar water heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors, and SRCC Standard TM-1,Solar pomestic Hot Water System and Component Test Protocol,Collectors in installed solar water heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and 2. Be installed at an orientation within 45 degrees of true south. ❑ R403.5 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida.Building Code,Residential or Florida Building Code,Mechanical,as applicable,orwith other approved means of ventilation. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. ❑ R403.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment. � R403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1.This code does not allow designer safety factors,provisions for future expansion or other factors which affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. • R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the , calculated total load,but not more than 1.15 times greater than the total load caiculated according to the procedure selected.in Section 403.6,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the - equipment shall not be less than the calculated latent load. 1 0/30/201 7 1 1;18 AM EnergyGaugeC�USA-FlaRes2014 -Section R405.4.1 Com � Page 2 of 3 r � • FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) � R403.6.1.1 Cooling equipment capacity.(continued) The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacture's expanded•performance data shall be used to select cooling-only equipment.This selection shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower cfm provided by the expanded performance data, the design value for entering wet bulb temperature and the design value for entering dry bulb temperature. Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for retum side gains if the return duct(s)is installed in an unconditioned space. Exceptions: 1. Attached single-and multi-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida-registered engineer,in attached single-and multi-family units,the capacity of equipment may be sized in accordance with good design practice. � R403.6.1.2 Heating equipment capacity ' R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section R403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times�greater than the design cooling load. . R403.6.1.2.2 Electric resistance furnaces. Electric resistance fumaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.6.1. ' R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric bumers shall not be less than the design load calculated in accordance with Section R403.6.1. � R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. ❑ R403.7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections - C403 and C404 of the Commercial Provisions in lieu of Section R403. ❑ R403.8 Snow melt system cantrols(Mandatory). Snow and ice-melting systems,supplied through energy service to the building,shall include automatic controls capable of shutting off the system when the pavement temperature is above 55°F,and no precipitation is failing and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F. ❑ R403.9 Swimming pools,inground spas and portable spas(Mandatory). The energy requirements for residential pools and inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSI/APSP-15.The energy requirements for portable spas shall be in accordance with ANSI/APSP-14 Q R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on-off switch that is mounted outside the heater to allow shutting off the heater without adjusting the thermostat setting. - � R403.9.1.1 Gas and oil-fired pool and spa heaters. All gas-and oil-fired pool and space heaters shall have a minimum thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013 when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights. � R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shail have a minimum COP of 4.0 when tested in accordance with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. O R403.9.2 Time switches. Time switches or other control method that can automatically turn off and on heaters and pumps according to a preset schedule shall be installed on all heaters and pumps. Heaters,pumps and motors that have built in timers shall be deemed in compliance with this equipment. Exceptions: • 1. Where public health standards require 24-hour pump operations. 2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation. O R403.9.3 Covers. Heated swimming_pools and inground permanently installed spas shall be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Outdoor pools deriving over 70 percent of the energy for heating from site-recovered energy,such as a heat pump or ' solar energy sour.ce computed over an operating season. ❑ RR404.1 Lighting equipment(Mandatory). A minimum of 75 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps. Exception: Low-voltage lighting shall not be required to utilize high-efficacy lamps. � R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights � R405.2 Pertormance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R-6. O R405.2.1 Pertormance ONLY. Ceilings shall have minimum insulation of R-19.Where single assemby of the exposed deck and beam type or concrete deck roofs do not have sufficent space,R-10 is allowed. 1 0/30/201 7 1 1:18 AM EnergyGaugeC�USA-FlaRes2014 -Section R405.4.1 Com Page 3 of 3 FORM R405-2014 � TABLE 402.4.1.1 ' AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA ._ Project Name: Cali Elevation D Builder Name: DRH Express Homes Street: �-- Permit Office: City,State,Zip: Zephyrhills, FL, Permit Number: - � Owner: Jurisdiction._ Design Location: FL,Tampa COMPONENT CRITERIA � CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. I Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sea�ed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walis shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. � Wiridows, skylights and doors The space between window/door jambs and framing and skylights and framing shall be sealed. Rim 'oists Rim joists are insulated and include an air barrier. � Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace wails. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations,and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit,or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity s aces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated,and sealed to the drywall. ' Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available, space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insuCated and the air barrier installed separating them from the showers and tubs. EleCtriCal/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 10/30/2017 11:18 AM EnergyGaugeC�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 . � FLORIDA ENERGY EFFICIENCY CODE , FOR BUILDING CONSTRUCTION _ Envelope Leakage Test Report - Prescriptive and Performance Method Project Name: Cali Elevation D Builder Name: DRH Express Homes Street: Permit Office: City,State,Zip: Zephyrhills, FL, Permit Number: - Design Location: FL,Tampa Jurisdiction: Cond. �loor Area:: 1828 sq.ft. Cond.Volume: 15849 cu ft. Envelope Leakage Test Results Leakage Characteristics Regression Data: C: n: R: CFM(50): Single or Multi Point Test Data HOUSE PRESSURE FLOW: E�'' 1 Pa cfm EqLA: 2 Pa cfm ACH: 3 - Pa cfm ACH(50): 4 Pa cfm 5 Pa cfm S�' 6 Pa cfm R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2,3 air changes per hbur in Climate Zones 3 through 8.Testing shall be conducted with a biower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the�tended weatherstripping or other infiltration control measures; 2. Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3.Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and ' 6.Supply and retum registers,if installed at the time of the test,shall be fully open. I hereby certify that the above envelope leakage Where required by the code official, �Z�s�'Ar performance results demonstrate compliance testing sliall be conducted by an �y�,� =�;"�dr,s, with Florida Energy Code requirements in approved third party.A written � 'f�f =' ', �,r . accordance with Section R402.4.1.2. re ort of the results of the test shall �" �t"`f�r'` '''"'�""'\�'��" � . P , � �' ::��'•:,,,.:...... � - be signed by the third party s� ..._.._;3�',:� ....._ � � � conducting.the test and provided to � 4�, '�n SIGNATURE: the code official. * r � 1��������� PRINTED NAME: DATE: BUILDING OFFICIAL: " - DATE: • 10/30/2017 11•18 AM EnergyGauge�USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 .FORM R405-2014 Duct Leakage Test Report Perf,ormance Method - FLORIDA ENERGY EFFICIENCY CODE - - FOR BUILDING CONSTRUCTION� � Form R405 Duct Leakage Test Report _ Performance Method Project Name: Cali Elevation D Builder Name: DRH Express Homes Street: Permit Office: City,State,Zip: Zephyrhills, FL, Permit Number: Design Location: FL,Tampa Jurisdiction: Duct Test Time: Post Constructioh Duct Leakage Test Results - CFM25 Duct Leakage Test Values Line System Outside Duct Leakage 1 System 1 cfm25(Out) 2 System 2 cfm25(Out) 3 System 3 cfm25(Out) 4 System 4 cfm25(Out) 5 Total House Sum lines 1-4 _ _ Duct System , Divide by Leakage (Total Conditioned Floor Area) _ (��,Out) I certify the tested duct leakage to outside, Qn, is not greater than the proposeci duct leakage Qn Duct tightness shall be verified by ��TI��Tg�,� specified on Form R405-2014. testing to Section 803 of the RESNET � ,,,�, t_;; o�, . Standards by an energy rater certified in � '�« "� _= ,�`� r - a c c o r d a n c e w i t h S e c t i o n 5 5 3.9 9, F' 'r'r'f" ``.-�;;'l�;'`'��, � Florida Statutes. � . _:iSEy_- Cf SIGNATURE: � �,�= Q � * , .. � PRINTED NAME: �G'p�.�.���'�. DATE: BUILDING OFFICIAL: -DATE: 1 0/30/2017 1 1:18 AM EnergyGauge�USA-FlaRes2014 -Section R405.4.1 Compliant S Page 1 of 1 i I � -Manual S Compliance Report Job: �" wrightsoft� �ate: oct�o,2o�a Entire House - By: _ Progressive Air Systems, Inc � 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 � � ' � • For: DR Horton/Express Lot 2 Blk 7 Silverado Ranch, Zephyrhills, FL • . • • . Design Conditions Outdoor design DB: 91.2°F Sensible gain: 20893 Btuh Entering coil DB: 75.4°F Outdoor design WB: 77.1°F Latent gain: 2966 Btuh Entering coil WB: 62.7°F Indoor design DB: 75.0°F Total gain: 23859 Btuh Indoor RH: 50% Estimated airflow: 1000 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHF Manufacturer: Carrier Model: CH14NB030*""*A+FB4CNP030 Actual airflow: 1000 cfm Sensible capacity: 23270 Btuh 111%of load Latent capacity: 3914 Btuh 132%of load Total capacity: 27184 Btuh 114%of load SHR: 86% • • • Design Conditions Outdoor design DB: 40.0°F Heat loss: 21.100 Btuh Entering coil DB: 69.8°F Indoor design DB: 70.0°F - Manufacturer's Performance Data at Actual Design Conditions - Equipmenttype: SpIitASHP Manufacturer: Carrier Model: CH14NB030**"A+FB4CNP030 Actual airflow: 1000 cfm - Output capacity: 25604 Btuh 121%of load Capacity balance: 32 °F Supplemental heat required: 0 Btuh Economic balance: -99 °F Backup equipment type: Elec strip � Manufacturer: Model: , Actual airflow: 1000 cfm _ - _ � Output capacity: 6.6 kW 107%of load Temp. rise: 20 °F Meets are all requirements of ACCA Manual S. 2017-0ct-30 11•1'9:34 �'�' wrightsoft� Right-Sulte�Universal 2D17 17.0.21 RSU25554 Page 1 ...on\Wrightsoft FileslE�ress homes\Cali 4EBB.rup Calc=MJ8 House taces: W Load Short Form Job: � WI'1��'1'tSO� � _ Date: Oct 10,2014 Entire House B,r: Progressive Air Systems, Inc � _. - - 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 I � • ' • � For: DR Horton/Express Lot 2 Blk 7 Silverado Ranch, Zephyrhills, FL , � • • . • 0 Htg Clg Infiltration ' Outside db( F) 40 91 Method Simplified , Inside db (°F) 70 75 Construction quality Semi-tight Design TD (°F' 30 16 Fireplaces 0 - Daily range - L Inside humidity (%) 50 50 Moisture difference (gr/Ib) 26 54 HEATING EQUIPMENT COOLING EQUIPMENT I Make Carrier Make Carrier � , Trade CARRIER Trade CARRIER Model C H 14N 6030""**A Cond C H 14N 6030"*"*A AHRI ref Coil FB4CNP030 AHRI ref Efficiency 8 HSPF Efficiency 11.5 EER, 14 SEER , Heating input Serisible cooling 22500 Btuh Heating output 29600 Btuh @ 47°F Latent cooling 7500 Btuh Temperature rise 27 °F Total cooling 30000 Btuh Actual air flow 1000 cfm Actual air flow 1000 cfm Air flow factor 0.047 cfm/Btuh Air flow factor 0.048 cfm/Btuh Static pressure 0 in H20 Static pressure 0 in H20 - Space thermostat Load sensible heat ratio 0.88 Capacity balance point=32 °F Backup: , In ut=7 kW, Out ut= 22477 Btuh, 100 AFUE ROOM NAME Area Htg load Clg�load Htg AVF Clg AVF (ftz) (Btuh) (Btuh) (cfm) (cfm) M bed 194 3196 � 3104 151 149 living room 270 2891 3627 137 174 . kitchen/dining = 349 4292 5088 203 244 bed3 - 155 1420 1098 67 � 53 ' � bath2 55 604 278 29 13 � bed2 168 `3411 3268 162 156 wc 21 24 35 1 2 M bath 114 1276 652 60 31 M wic 66 77 112 4 5 laundry 39 45 668 2 32 bed4/den opt 169 1866 1306 88 63 � A/C closet 19 181 114 9 5 i foyer 200 1817 1542 . 86 74 I Calculations approved by ACCA to meet all requiremerrts of Manual J 8th Ed. I III '0� WI'I I1tSOft" 2017-Oct-3011•19:34 ^'�- � 9 Right-Suite�Universal 2017 17.0.21 RSU25554 �� Page 7 ...on\Wrightsoft Files\Express homes\Cali 4EBB.rup Calc=MJ8 House faces: W � Entire House d� -1820 21100 20893 1000 1000 Other equip loads ' 0_ 0 ' Equip. Qa 1.00 RSM 20893 Latent cooling . 2966 -- TOTALS 1820 21100 23859 1000 1000 i li ' - I � - ' Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. �- wri htsoftm 2017-Oct-3011:19:34 ^'� 9 Right-Suite�Universal 2017 17.0.21 RSU25554 �� Page 2 ...on\Wrightsoft Files\Ezpress homes\Cali 4EBB.rup Calc=MJB House faces: W Pro ect Summar Job: • -�- wrightsoft� Entire House y Byte: o�c,o,zo,a - Progressive Air Systems, Inc 5907 Dashe�Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 � ,� � � ' � � For: DR Horton/Express Lot 2 Blk 7 Silverado Ranch, Zephyrhills, FL Notes: � - • � • Weather: Tampa Intl AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 40 °F Outside db 91 °F Inside db 70 °F Inside db 75 �F Design TD 30 °F Design TD 16 °F Daily range L Relative humidity 50 % Moisture difference 54 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 17539 Btuh Structure 16295 Btuh Ducts 3561 Btuh Ducts 4598 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh none (none) Humidification 0 Btuh Blower 0 Btuh , Piping 0 Btuh Equipment load 21100 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 20893 Btuh . Method simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 2360 Btuh Ducts 606 Btuh �Central vent (0 cfm) 0 Btuh Heating Cooling (none) - Area(ft2 1820 1820 Equipment latent load 2966 Btuh Volume�ft3) 16012 16012 Air changes/hour 0.26 0.14 Equipment total load 23859 Btuh Equiv.AVF(cfm) 69 37 Req. total capacity at 0.75 SHR 2.3 ton Heating Equipment Summary Cooling .Equipment Summary Make Carrier Make Carrier Trade CARRIER Trade � CARRIER - Model CH14NB030�*"'A Cond CH14NB030***''A AHRI ref Coil FB4CNP030 AHRI ref Efficiency 8 HSPF Efficiency 11.5 EER, 14 SEER Heating input Sensible cooling 22500 Btuh Heating output 29600 Btuh� 47°F Latent cooling 7500 Btuh Temperature rise 27 °F Total cooling 30000 Btuh Actual air flow 1000 cfm Actual air flow 1000 cfm Air flow factor 0.047 cfMBtuh Air flow factor 0.048 cfm/Btuh - Static pressure 0 in H20 Static pressure 0 in H20 Space thermostat Load sensible heat ratio 0.88 Capacity balance point=32°F - Backup: Input= 7 kW, Output=22477 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J Sth Ed. �_ '�" wrightsoft� Right-Suite�Universal 2017 17.0.21 RSU25554 2017-Oct-30 11:19:34 �� ...on\Wrightsoft FileslExpress homeslCali 4EBB.rup Calc=MJ8 House taces: W Page 1 J � !. � FOaM R405-2014 RESIDENTIAL ENERGY CONSERVATION CODE D OCUMENTATION CHECKLIST Florida Deparfinent of Business and Professional Regulation Simulated Performance Alternative (Performance)Mefhod Applications for compliance with the 2074 Florida Building Code,Energy Conservation via the residential Simulated Performance method shall include � - ❑ This checklist ❑ A,Form R405 report fhat documents that the Proposed Design complies with Secfion R405.3 of the Florida Energy Code. This form shall include a summary page indicating home address, e-ratio and the pass or fail status along wifh summary areas and types of componen[s, whether the home was simulated as a worst-case orientafion, name and�version of the compliance software tool, name of individual completing the compliance report(1 page).and an input summary checklisf fhat can be used for field verification (usually 4 pages/may be greater). ❑ Energy Performance Level(EPL) Display Card(one page) ❑ Mandatory Requirements(three pages) . ' Required prior to CO for the Performance Method: ❑ Air Barrier and lnsulation Inspection Component Criteria checklist(Tab/e R402.4.1.1 - one pageJ , - ❑ A completed Envelope Leakage Test Report(usually one page) ❑ If Form R405 duct leakage type indicates anything other than "default leakage; then a comp/eted Form R405 Duct Leakage Test Report(usually one page) EnergyGaugeB-USRCZB v5.1 1 0/30/2017 1 1:5926 AM - Page 1 of 1 _,OS-26-21-0080-00700-0020 � Pasco County Property Appraiser Page 1 of 1 .. � Data Current as Of: Weekly Archive = Saturday, February 17, 2018 Parcel ID 05-26-21-0080-00700-0020 (Card: 001 of 001) Classification 00 - Vacant Residential Mailing Address Property Value DR HORTON INC A`g Land $0 12602 TELECOM DR Land $2,661 TEMPLE TERRACE FL 33637-0935 Building $0 Physical Address Extra Features $0 � 6896 SILVERADO RANCH , BOULEVARD ZEPHYRHILLS, FL 33541 7ust Value , $2,661 ASSeSsed (Non-School Amendment 1) $2,661 Legal Description (First 4�ines) SILVERADO RANCH SUBDIVISION PHASES 6, 8 &9A PB 75 PG 075 Taxable Value $2,661 BLOCK 7, ' LOT 2 Jurisdiction City of Zephyrhills - � Land Detail (Card�001 of 001) Line��Use � Description�2oning �Units Type �Price �'Cond�ition�;�e�� 1___� , 0100 SFRv_,��,�MPUD �6,000.00 SF ;�^ $0`40 i 1.00 � $2,400 4 2 � 0100—�SFR � MPUD j 1,043.00 SF ; $0.25 � 1.00 ; $261 Additional Land Information .,.��f _�__ FEMA Acres ' 0.16 (Tax Area� 30SI I Code � -- �� Residential Code �� SLVRCPI i 4 � ! � Building Information - Use 00 - Unimproved (Card: 001 of 001) Unimproved Parcel 00 - Unimproved Extra Features (Card: 001 of 001) Line � � Description 1Year Units � (Value No Extra Features Sales History- See All 6 sales Previous Owner: DUNE FL LAND I SUB LLC Month/Year+Book/Page �1Type �i�_�� �v_�D�OR Cod�e-ConditionAmount �12/2017 19649 / 0964 ; Warranty Deed { 05 Vacant Multi-Parcel Sale 05/2017T 9535 / 0546 �� u Certificate ofTitle�� � 05 � Vacant ��Multi-Parcel Sale �11/2016 Ji9462 / 0384 , jMineral Rights or Royalty Transfer�` 05 �� Vacant (Multi-Parcel Sale http://search.pascopa.com/parcel.aspx?parce1=2126050080007000020 2/23/2018 � � �` ': �'145�� �Q��T'�, �L��IDe� - �,, � �� Permft No. 1��la � Date Perml�ted �-?�.�-T� �Builder NamelOwner Name C�C-. Cantrol# County Parce!No. OS-�`2�l���d— t�D7t?Q-01�20 SubDiv: J�r�l��Z) ' AddresstLocation U� � � /'�G� ����f�� +��,.� CiassificationlType of Use CS�~�i l�' �lCj I',� `;,.°�t TRANSPORTATIOIV{MPACT PEE Rate: Sq.Ft Unit: 2�3�� i' _� �;:�` Exempt �Yes [] No Now Determined $.,.._ � Impact Fee Amount $. �i���� Zone No. TRZ: i:"� SGHOOL tMPAGT F�E F�' Account (056} Singte-Family petached House Amount $ ��'j 7b�. � ` (057} Mobile Home (058) Other Resldentlal � 123) Collection Fee � Exempt [�Yes a IVo Haw petermfned PARKS�iRdA RECREA'ffON FEE Lend Accaunt Land Gredit Land Totai Recreation Acaount Recreatian Credit �Recrsatian Tota! I Zons TOTAL AtdIOUNT $ `���'.�,� Exempt �Yes ❑ No Fiow Determined , LiBRARY FEE t� Land Account Land Credit Land Tptal � Facility Account Facility Credit Facility Totai , Exempt ❑Yes ❑ No How Determtned Tot�ii Amoun�����, � ^ ,I ' RESOURCE FEE ERU TOTAL AMC?UNT � Prepared By Checked By ; iVq CERTiFaCA'i'E OR(3CCUPANCY WI�L$E ISSUEp OR FIPfAL INSPECTlON PERPORMED UNl'lt.THE TO'fAL AMCDUNfiS LlS7'ED HAVE BEE�1 PAtD aIND � , FtECE1PTEC�FOR BY A CENTRAL PERMI'i"1'ING OPFiCE OF PAS+�t'�COU�ITY ,. - Acknowledgement hetow does not Imply acceptance of concurrence,hut slmply ceceipt of•a capy of thts form,plaeing the bullding perrrilt owner an notice af ihis assessment and th�condittons of payment for same. RATE RECEIVED BY RECEIPT NO. DATE BY , . a � EN�VIRONMENTS FOR �`� � � . , ��'�c� .� � � � 'y� � SRE ID:3B3015 LOT.2 BLOCK.7 HOUSE:8898 STREET:SILVERADO RANCH BLVD CITY:ZEPHYRHILLS STATE:R ZIP:33541 COUNTY:PASCO ACCOUNT#:809DRHFL BUILDER:D R HORTON SUBDNISION:SIWERADO COMMUNITY�39163 PLAN:NDP 12/12I2018 PROGRAM:HERS�100% TESTER:EFL IECC:2008 CLIMATE ZONE: PROPERTY OWNER: PROPERTY ADDRESS:8898 SILVERADO RANCH BLVD,ZEPHYRHILLS,FL 33541 � TEST BLOWER DOOR RESULT PASS TESTER: Micheel Silberetein DATE:07N82018 ' CORRECTION BUILDER RATER TESTNAME - NEEDED VERIFlED VERIFIED WA 5.1 Attic Access Penel(Polly gasketed and insulated) X 52 Attic drop-down Stair(fuly gasketed and insulated) X 5.4 Recessed Lighting Fixtures(ICAT labeled and sealed to drywall) X 5.5 Whale-house Fan(insulated gasketed to the opening X 7.3 Fresh air ventilation installed per program specs X Blower poor � BUILDING ORIENTATION PRO[3RAM CODE PROGRAM CODE VOLUME CU. VOLUME CU. SHELL SQ: SHELL SQ. NIA 15,849 0 0 � PROORAM CODE PROGRAM CODE PROGRAM CODE �CFM 50 CFM 50 ACH 50 ACH 50 %of Shell %oI SheO BDTeIgBt 0 1,849 7 BD Aeluel 1,282 4.85 Meter# Room Pressure Test MstBdrtn 0 Bdrtn2 0 Bdrtn3 � ' Bd�m 4 0 Bdrtn 5 0 Rm 1 0 I Rm 2 0 Rm 3 0 Other 0 CO�etedora Enetgy Ster Quelified Appliancea7 Efiaent Lighting Pael�ge? 60 or>Of Herdwired Lighfs Must Be CFL Or LED Low Flow Fauceb,ToOets etc4 Progtammeble Themastet7 CeAified Green Pmgrem Leval Requirea Vsual InspecUon Meehaniral System Ilem Loea6on ManufadmerName Mode1�1 ModeIS2 Model�i Model�4 SYSTEM 1 WATER HEATER SYSTEM2 WATER HEATER SYSTEM3 WATER HEATER SYSTEM 4 WATER HEATER SYSTEMI FURNACE SYSTEM 1 HVAC OUTDOOR pUTSIDE � UNIT SYSTEM 1 HVAC INDOOR COIL SYSTEMI �ACAHU(HEAT �NTERIOR PUMP) SYSTEM2 FURNACE SYSTEM 2 HVAC OUTDOOR UNIT SYSTEM 2 HVAC INDOOR COIL SYSTEM 2 �AC AHU(HEAT PUMP) SYSTEM 3 FURNACE SYSTEM 3 HVAC OUTDOOR UNIT SYSTEM 3 HVAC INDOOR COIL SYSTEM 3 �AC AHU (HEAT PUMPj SYSTEM 4 FURNACE SYSTEM 4 HVAC OUTDOOR UNIT SYSTEM 4 HVAC INDOOR COIL SYSTEM 4 �AC AHU (HEAT PUMP) BUILDING SPECIFICATIONS BUILDINGCHARACTERISTICS �ASDESION-VALUES ASBUILT-VALUES . COMMMENT #OFBEDROOMS(REM) NA NA CEILING FLAT(REM) NA NA SEALED ATTIC(REM) NA NA I VAULTED CEILING(REM) NA NA FOUNDATION WALLS(REM) NA NA EXPOSEDFLOOR(REM) NA NA ABOVE GR,4DE WALLS(REM) NA NA DUCT SUPPLY R-VALUE(REM) NA NA DUCT RETURN R-VALUE(REM) NA NA PROGRAMMABLE THERMOSTATS(PRI� WATER HEATER TYPE(PRI� WATER HEATER FUEL TYPE(PRIF) TEST BLOVIlER DOOR RESULT�PASS TESTER:Micheel Siiberstein DATE:O7/192018 BUILDING SPECIFICATIONS , ', : BUILDINGCHAR4CTERISTICS ASDESIGN-VALUES ASBUILT-VALUES COMMMENT WATER HEATER SIZE, EFFICIENCY 8 LOCATION (PRI� INFILTRATION(HOUSE LKG)ACH(REM) NA Htg:4.85 Clg:4.85 ACH @ 50 Pascais FRESH AIR VENTILATION TYPE(PRIFj VENTILATION FAN MANUFACTURER(REM) NA NA VENTILATION FAN MODEL#(REM) NA NA VENTILATION FLOW REQUIRED(REM) NA NA VENTILATION E�UIP.RATED CFM(REM) NA NA VENTILATION#OF FANS(REM) NA NA VENTIL4TION TIME-HRS/DAY SPECIFIED(REM) NA NA VENTILATION TIME SET BY HVAC CONTRACTOR- MINUTES PER HOUR(PRI� FRESH AIR VENTILATION FAN WATTS(REM) NA NA MEASURED FAN WATTS OR PER MANUFACTURER'S SPEC'S(PRI� INTERIOR%OF CFL'S(PRIF) INTERIOR%OF PIN-BASED(PRI� EXTERIOR FIXTURES(%)(PRIF) GARAGE FIXTURES(%)(PRI� DISHWASHER(PRI� REFRIGERATOR(PRI� FOUNDATION TYPE(PRI� SLAB TYPE(PRIF) SLAB AREA(PRIF) SLAB DEPTH(PRIF) SLAB FULL PERIMETER(PRIF) SLAB GR4DE(PRIF) FLOW RING(PRIF) HEATING(REM) NA NA COOLING(REM) NA NA AIRSOURCE HP(REM) NA NA WATER HEATING(REM) NA NA TEST.DUCT BIASTER RESULT PASS TESTER: Michael Silberstein DATE:07/1912018 TOTAL CONDITIONED FLOOR AREA 0 1,828 (CFA SQ Fn DUC7 LEAKAGE TO OUTSIDE�TAROET 0.00% 3.00% TOTAL DUCT LEAKAGE%TARGE! 0.00% 6.00% SYSTEM 1 SQ FT SERVED(CFFa D 1,828 P0.ST CANSTRUCTION SYSTEM 1 DUCT LEAKAGE TO OUTSIDE 0 55 SYSTEM 1 DUCT LEAKAGE TO OUTSIDE �� SYSTEM 1 DUCT LEAKAGE TO OUTSIDE �nfinity% 0.60% (CFM25)TARGEI' (CFM25)ACTUAL (%OF CF/�ACTUAL SYSTEM 7 TOTAL DUCT LEAKAGE 0 146 SYSTEM 1 TOTAL DUCT LEAKAGE SYSTEM 1 TOTAL DUCT LEAKAGE(%OF NaN% 0.00% (CFM2�TARGET (CFM2�ACTUAL CF/�ACTUAL SYSTEM 2 SQ FT.SERVED(CF/U 0 0 SYSTEM 2 DUCT LEAKAGE TO OUTSIDE Q � SYSTEM 2 DUCT LEAKAGE TO OUTSIDE SYSTEM 2 DUCT LFAKAGE TO OUTSIDE (CFM25)TARGET (CFAA2�ACTUAL (%OF CFl�ACTUAL SYSTEM 2 TOTAL DUCT LEAKAGE 0 0 SYSTEM 2 TOTAL DUCT LEAKAGE SYSTEM 2 TOTAL DUCT LFAKAGE(%OF (CFM25)TARGET (CFM2�ACTUAL CF�ACTUAL SYS7EM 3 54 FT.SERVED(CF/U 0 0 SYSTEM 3 DUCT LEAKAGE TO OUTSIDE SYSTEM 3 DUCT LEAKAGE TO OUTSIDE SYSTEM S DUCT LEAKAGE TO OUTSIDE (CFM2�TARGET -� �- (CFM2�ACTUAL "" - .' (%OF CFA)ACNAL SYSTEM S TOTAL DUCT LEAKAGE SYSTEM 8 TOTAL DUCT LEAKAGE SYSTEMSTOTALDUCTLFAICAGEQYoOF (CFM2�TARGET � � (CFM2�ACTUAL CFA)ACTUAL SYSTEM 4 SQ FT SERVED(CFP� 0 0 SYSTEM 4 DUCT LEAKAGE TO OUTSIDE � p SYSTEM 4 DUCT LEAKAGE TO OUTSIDE SYSTEM 4 DUCT LEAKAGE TO OUTSIDE (CFM25)TARGET (CFM2�ACTUAL (%OF CFA)ACNAL ' . r TEST.DUCTBLASTER RESULT �PASS TESTER:MicheelSiiberatein DATE:07A82018 � ' � SYSTEt� 4 TOTAL DUCT LEAKAOE� SYSTEM 4 TOTAL DUCT LEAKAGE SYSTEM4TOTALDUCTLEAKAGE(%OF (CFM25)TARGET � � (CFM2S)ACTUAL ❑CFl�ACTUAL - BUILDING SPECIFICATIONS BUILDINGCHARACTERISTICS -AS�DESIGN=VALUES� ASBUILT-VALUES� ' COMMMENT DUCT LEAKAGE TO OUTSIDE(REMj NA - 0.006�CPM25/CFA ` TOTAL DUCT LEAKAGE(REM) NA' - � 0.08 CFM25/,CFA FLOW RING(PRIF) FLORIDA ENERGY EFFICIENCY CODE . . FOR BUILDING CONSTRUCTION � • Envelope Leakage Test Report � � ' Prescriptive and Performance Method Project Name: SILVERADO Builder Name: D R HORTON Street: 6896 Silverado Ranch Bivd Permit O�ce: City,State,Zip: Zephyrhills,FL 33541 Permit Number• Design Location: 6896 Silverado Ranch Blvd(Lot 2) Jurisdiction: Cond.FloorArea: 1828 Cond.Volume: 15849 Envelope Leakage Test Results Leakage Characteristics Regression Data: C: n: R: CFM(50): 1282 Sin le or Multi Point Test Data ELA: 71 HOUSE PRESSURE FLOW EqLA: 167 1 50 Pa 1282 cfm ACH: 4.85 2 0 Pa 0 cfm SLA: .04 3 0 Pa 0 cfm ACH(50)* 4.85 4 0 Pa 0 cfm *For prescriptive projects,tested leakage must be<=7 5 0 Pa 0 cfm ACH(50). For performance projects, tested leakage must be<=the ACH(50)shown on Form R405-2014 6 Pa cfm for this project. R402.4.7.2 Testing.The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zones 1 and 2.Testing shall be conducted with a blower door at a pressure of 0:2 inches w.g.(50 Pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statutes or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party A written report of the results of the test shall be signed by the party conducting the test and provided to the code o�cial.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration 3.Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be tumed off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. , I hereby certify that the above envelope leakage performance results , demonstrate compliance with Florida Energy Code requirements in accordance with Section R402.4.1.2. Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statutes p4�H�5T9T,�. or individuals licensed as set forth in Section ;=r O� �',,`°� __ � .� � 489.105(3)(f),(g),or(i)or an approved third party.A �,���,;*��,�;F�;�� o , written report of the results of the test shall be signed � $" � Digitally signed by Michael by the third party conducting the test and provided to � -~'',J�- - > Silberstein th@ COde offlcial. * �� ' 4 /�ti������Date:2018.0719 15:47•12 EDT �ll /� CN=Michael Silberstein,O=TopBuild f'�'G, J� ���� � Home Services,OU, �D{y�'� EMAILADD RESS=Mi chael.Sil b erste i Signature• n@topbuild.com,C=US Printed Name: Michael Silberstein BUILDING OFFICIAL: Date: 07/19/2018 DATE: Thank you for allowing Top6uild the opportunity to provide the above services for you.Please feel free to contad me with any questions. 10/2512017 383D15 �. ��� �� �� a . �������� . � . ���a��������������. ��,fi�� a���;.����� ��� , T'ni�me h� been prof�.ssionaliy insuiat�d��iith �1�.� V . , � � � �� �wens Corning . •' "' ` �' pROPlNK L77 Loosefifl Insuiatian �s��rl�lt�fG� � � (f ob Site Address) � - Name ` - , _ Address ' " � Gr� ' Stat� Zip Owens Corning FRt3Pl�<� L77�.aosefslt Insuiation Owens Cornin,Insulating Systams,LLC will 3ct_pt no r�sponsi'6ili.�when the pradud is not ins[+Iled in ac:ar�anc��Nit`�tF.e produd label.SW3d R-aalcz;s previded'oy installing the n_�uin_d number�f•oags at a�ic:<ns not tess ttran ffie�acel�d miriinum 8;iccness.losfaltaton oi the r�qui%d number ai ba�s maf neld mor=;han tf;e Sgacrie� minimum�:iuness.Fslurw by tt7e insta[Ezrtn pro��ide ooth the requin_d bags and at feast the minimam thic'.mass wiit rrsutt in toaver insc,tatian R-vatue. � Sp.:.�icticn arCc=n 9tcwA�cs A��_ � _ _ Watts •C�§2s� I�utwn.:fee 2�9kqiicl ��feaan `ifii�eaa adtt� " " (�sted =O�iq 'Ga'!'?N' Gg�hr V (tiri+w'Mr;;SrJt 4nawe F,uro qit yfa�r+i�_ . _.f�E� . T�"�C■�. . 15idim� : c.,we G,mi� 16ieuea. Lth:a$ 4sGa.5t3 � .r,�ta�4dt _.....st,Ft_ : �i�,v G��nY�rt;c:icn ��� ?�J � 15:.9 0.l8C �75 i75 1�4 Zc3 3S' t3 877 !IS O.T,F R�y� e'�19 83 I.+2 O,ie3 4T 575 15 ?x� 3.5 !3 7ti i33 O.a?8 Number of�a;s:iszd 'L"'� R�_.'. 9.4 IQ5.] 0.7�� 775 7.3 !y ^vc+ 35 23 qg.� Zp.3 . 0.7! .R-io 11..2 99.$ 0.?ed 9.r0 9.:0 22 Z+cS S.� J3 �s'.i 13.1 0�6 Esa�r.ac`d�-•fatueai �?Q t1Q 77.� Q±73 ta.S i2'S 73 1a�5 SS t-4 St; I°?� O.c+2 or'arta,s�nmia�cn ,q.7S i;,3 59a da:5 1275 12?5 �d Z,c6 S..i 1.3 ?CO �c;� O.y� MacFco«�(sq.2j I�h 1S �'-�h� 'J�.• 49.d O.00 • ia.:5 14.;5 Tk:rs�raducishawsr.eog�aie;ed'mg. a<(7 x..�o u.s �!z ¢�#7 �s:s �5as in5Ui8ticn n 3C.iC �"Q �� �.}f 49�0 t9�0 1950 �'lttCNPSS Ot!1'SSCiIdilOtt � � � • Cathedcat C.:iling ESoor D'J',N1�i�fdYICLLS ' I�iouq leoied'�if( Ituunun � �ALg?� �!1'rima ui�nt!6c' Fnr.e lSniaun �(avAed�')eeiq��IF+m�ai-. "-�� :�i�um w�hc�� s>L'laten . Fnke Bidrus _(hs_:+rG�.Fe G�er�g,e�iiq I6Q6i�fe , Ari4it ( � ni6neu lEchrCuie Caera�ehr3�q, IOCO#it .�. h+�Ert_ � :0 7x3 i:± 34.2 Z.6 03?5 ?Q ?s3 t.a I4.0 ZSS 034b - IB 3ct0 t.# �Oc 327 �IID9 ?8 �SO 1.+ ?0.6 327 I.Oi9 49 �ct2 13 19.i 5+0 1.781. it 1u[2. 1.4 24.1 393 1.31] O�,vens Conin;T'�^;la;s fib�r6lank:t and laossfill ihermal insulat�ans,when instalfed�erthz manuiac',urars coverage charts�t':d r_commendations,�Nitl pravide the laoeled R�value THE FaLLOWING PRODUCTS HAYE BEEN INSTALLED IN THIS HOUSE. Kraft Unfaced F4II Laasefiil Fi-ZS R-Yafue Thickness tto.g[cgs. Coverag=Area Ceilings ❑ ❑ Q Q ❑ Q ❑ Q ❑ ❑ Floors CI LI ❑ ❑ ❑ ct ❑ a Q ❑ wa�rs � o ❑ o ❑ o ❑ ❑ ct ❑ ❑ � Basement ❑ � Q ❑ ❑ ' ❑ n o ❑ a � . Crawlspace ❑ ❑ El ❑ ❑ v ❑ ❑ Ct ❑ Q � - Attic Cl ❑ 0 0 ❑ ❑ a o a ❑ - � � Contractor Date Builder Date aztiei Iusulation,LLC Cornpany �yQ�9��� '-- Company � , Address Clearwa���,�,33fi52 Address �'�"°�"�� - 13)223-5094 Fhor�e Phone . O{NERiS C4f3i�tSt�tG IRtSCiLAlIltiCi SYSTEMS,tLC ONE OV�/ENS CORNING PARKW/AY • . TOLEDQ,OHIO,USA43659 Pub.Dlo.10018804•B.Print�dinU.S.A.Novembec2415.TnecolorPlNKisa ,� u� � t-S�O-GET-P1NK' registeredtrademar�of0ovensC�ming.fl201b4wensCaminglnsulating www.awenscarning.aom - Systems,LLC.AII Rights Raserved. l.:S . . . . i. t. ,i . t t t t t , ttt . t t t t t� t fY '� . � � t < t t � u e i ui . r + r . , , � . . , . . ... . . . . . . . .. � C - 5335 - 8TH STREEI" � - ' (813)780-0020 CEItTIFICATE OF OCCUPANCY � Address: 6896 SILVERADO RANCH BLVD Owner: DR HORTON INC ZEPHYRHILLS, FL. 12602 TELECOM DR Subdiv: SILVERADO TEMPLE TERRACE FL 33637-0935 Parcel: 05-26-21-0080-00700-0020 Work Type: 101-NEW CONST/SFR Construction Type: NOT APPLICABLE � Sprinklers Use Classification: NOT APPLICABLE Permit Number: 19368 Da : 7/20/2018 � . ISS D BY: BUILDI OFF1CIqL ; WATER MUST BE CHANGED OVER WITHIN 10 DAYS OF ISSUAIVCE GARBAGE DEPOSIT MUST BE APPLIED FOR PRIOR TO ISSUANCE