Loading...
HomeMy WebLinkAbout18-19372 CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 19372 ' � . BUILDING PERMIT �INGLE FAMILY RESIDENTIAL I � . � PERMIT INFORMATION � � LOCATION INFORMATION Permit#:19372 Issued: 2/28/2018 Address: 6912 SILVERADO RANCH BLVD Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Lot(s): _ Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 355,185.45 Total Fees: 11,795.19 Subdivision: SILVERADO ' Amount Paid: 11,795.19 Date Paid: 2/27/2018 Parcel Number: 05-26-21-0080-00700-0040 CONTRACTOR INFORMATION OWNER INFORMATION Name: D R HORTON INC Name: DR HORTON INC Addr: 12602 TELECOM DR Address: 12602 TELECOM DR TAMPA, FL. 33637 TEMPLE TERRACE FL 33637-0935 Phone: Lic: Phone: 813-549-1968 Work Desc: CONSTRUCT SINGLE FAMILY 3,153 SQ FT APPLICATION FEES BUILDING FEE 1,361.12 ELECTRICAL FEE 282.60 PL MBING FEE 188.40 MECHANICAL FEE 131.88 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE-sfr/100% 4,828.00 SCHOOL IMPACT FEE-sfr/1% 48.28 TRAFFIC IMPACT FE 9% 3,595.68 TRAFFIC IMPACT FEE 1°/a 36.32 _ � � � � `� � � \ � �� � .�� � Ins ections Re ired FOOTER 2ND ROUGH PLUMB MIS INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION PEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposecl for the initial inspection or ' first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES; NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this properly that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing, consult with your lender or an attorney before recording your notice of commencement." Complete Plans, Specifications and Must Accompany Application. All work shall be pertormed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. � � CONTRACTORS SIGNATURE PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO , CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER O� 0 i111tA_ `�.�--�-.��. �. � c . . .�.t. �'�',"'�j" h / J ,��_ � V ,=� . `�"'. ..:........ . � City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: �'�h� ��-�,L Date Received: �- ZZ--[ � Site: � ��U�� �, � Permit Type: �G < <�'� � Approved w/no comments:❑ Approved w/the below comments: �7'J Denied w/the below comments: ❑ s�� ��� This comment sheet shall be kept with the pernut and/or plans. , �. ����� � Kalvi Switz Plans Examiner Date Contractor and/or Homeowner (Required when comments are present) D R HORTON INC-6912 Silverado Ranch Blvd-3,153 SQ FT � I ,. ' - o umn � SQ. FEET PRICE MAIN OR LIVING: 3,153 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 355,185.45 FEE SHEET $ 1,256.00 ADDRESS $ 40.00 DRIVEWAY $ 40.00 BUILDING: $ 1,361.12 � ELECTRICAL: $ 282.60 PLUMBING: $ 188.40 MECHANICAL: $ 131.88 SUB-TOTAL $ 1,964.00 TOTAL $ 1,964.00 SEWER: N/A I ' WATER: N/A IRRIGATION: $ - TOTAL: $ - WATER METER: N/A IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 � 5% $ 26.35 , TOTAL: $ 553.35 SUB-TOTAL $ 2,517.35 � PARK IMPACT FEES $ 769.56 SIF'S: $ 4,828.00 100.0% $ 4,828.00 1.0% $ 48.28 TOTAL: $ 4,876.28 T I F'S: $ 3,632.00 � 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 11,795.19 � . _ __iiiiiiiiiiii iiiii iiiii iiiiiiiiii iiiii iiiii iiiii iiiii iiii iiii ' • � 2018010493 '� ` - Rcpt:1925414 Ree: 10.00 � '�-" DS: 0.00 IT: 0.00 ' 01/19/2018 K. M. , Dpty Clerk Permit No. Parcel ID'No �� 'Z(n'Z���Q��'�U�O �C��1�� NOTICE OF COMMENGEMENT State of � 1 1 Q__ County of P�-tS V._/ THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 713,Florida Statutes, the following information is provided in this Notice of Commencem nt: "�� C 1. Description of Property Parcel Identification No. � (�� � ��(�(� � ' 'l I �UP 1�7�1 l) P�(?� �n, R. � q� , ' Street Address: � l�Z ` l`►��-Y'cac�0 �►'1 c� 13��T�1T7�2 ���r h i!Is, F( 336-k� 2. General Description of Improvement y_,'e� J l �Ct �� �C� VI/��� I l� 'r�i(r P✓� �{� V � PRULA S 0'NEIL,Ph D PRSCO CLERK & COMPTROLLER 01/19/2018 02:46 m 1 of 1 3. Owner Information or Lessee information if the Lessee contracted for the improvement: OR BK ���� PG ���� • (�,r /) J1 ���LQ•Z I Q.��/1�l �r �Cl�V1�i��C�_ c���.3� _�L Address City State Interest in Property: _ ��.� ��(�1�14 �-Q Name of Fee Simple Titleholder: (If different from Owner listed above) ' Address �- �, �I�r�n ��P �ity State 4. Contractor _ _/__����ame "�Q.Ie�M �r I�1�1Mt�Q �J ��_ �� Address Ci State Contractor's Telephone No.: 5. Surety: /1,/,��- - Name' ,4ddress City � State Amount of Bond: $ ��� 7elephone No.: 6. Lender: /�, �/y. Name Address � City State Lender's Telephone No.: 7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)(7), Florida'Statutes: l�a �/�'� �-�c��-e Nam� I_��o O 2 `�JP��L►�l ��' �uLca/�G ����� A dresa s � ity �� ^�� Sta� Telephone Number of Designated Person: �3 -� �'�(�— ��D 8. In additlon to hirnself,the owner designates /�/�/7 of to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statutes. Telephone Number of Person or Entity Designated by Owner: 9. Expiration date of Notice of Commencement(the expiration date may not be before the completion of construction and final payment to the . contractor,but will be one year from the date of recording unless a different date is specified): WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES,,AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalty ofperjury,I declare that I have read the foregoing notice of commencement and that the facts stated therein are true to the best of my knowledge and belief. STATE OF FLORIDA COUNN OF PASCO , Signa re o Owner or Lessee,or Owner's or Lessee's Authorized , Officer/ irector/Partner/Manager , '�S.�i� �P�f'P�/L/ '_ "�•�J t I '�/1 �? Signatory's Title/Office `�� The foregoing instrument was acknowledged before me this 3 day of�nl_�C{{i(J,2p (�by_ 1 V 1 Q�G� �"�p�,L�f\Y� � as ���P[f�'"��/'�/ � (type of authority,e.g.,officer,trustee,attomey in fact)for , — 1 )- • ��D��n T'�C (name of party on behalf of whom instr ment was executed). Personally Known[y�OR Produced Identification❑ Notary Signature � 'fype of Identification Produced Name(Print) � �°.� Notery Public 5tete of Florida � . . Mlohelle Moysa `�,, My Commlorlon 00 067s21 "t'o i �kq1f901�/21l"rtl2b wpdata/bcs/noticecommencement�c053048 � � � , o �� ��°��'���'FL06?[��A, ���6�m'3"`e"���A��C� � � � :�:�;�:�', �. . THIS IS TCJ CERTIFY THAT THE�OREt�pINC iS l� • p� y�' -�:�� •,,,,3,� TRUEAND CORRECT COPY OF THE DQCUMENT �� a ��^'�� . � :� _'� ���� ��.��,,;. " , � -� � �i OfV FILE OR OF PUBLIC RECORp IN THIS OFFICE ��"� !�^� �j`�3'���� ��.�. WITNESS MY�,�IV[3"AND C)FFICIAL SEAL THlS ��'� � �' `���� ��� .�' . '�v, .;��g�}'��}�.�, ,�'��_r ���, ��DAY OF 2 �� � �� '�� � �3 PAULR S O'IV IL, C \���., ���• � &COMPTROLLER ,��, �: . �,a� g� DEPUTY CLERK � �a �o.� OS-26-21-0080-00700-0040 � Pasco County P"roperty Appraiser Page 1 of 1 '� Data Current as Of: Weekly Archi've- Saturday, February 17, 2018 Parcel ID 05-26-21-0080-00700-0040 (Card: 001 of 001) Classification 00 - Vacant Residential Mailing Address " " Property Value DR HORTON INC Ag Land $0 12602 TELECOM DR Land $2,661 TEMPLE TERRACE FL 33637-0935 Building $0 Physical Address Extra Features $0 6912 SILVERADO RANCH BOULEVARD Just Value $2,661 ZEPHYRHILLS, FL 33541 AsseSsed (Non-School Amendment 1) $2,661 Legal Description (First a�ines) SILVERADO RANCH SUBDIVISION PHASES 6, 8 &9A PB 75 PG 075 Taxable Value $2,661 BLOCK 7 LOT 4 7urisdiction City of Zephyrhills Land Detail (Card: 001 of 001) Line �Use Description,Zoning ,Units jTyp Pr,ce _ _Cition ;Value _�__1 ��__0_100__ _ SFR_�_C MPUD 6,000.00 SF _$0.40 � 1.00 � $2,400 2 � 0100 � SFR � MPUD � 1,043.00 l ~SF � $0.25 ; 1.00 j $261 Additional Land Information Acres 0.16 Tax Area+ 30SI FEMA Residential Code '` SLVRCPI �' � j Code �-�---- ' Building Information - Use 00 - Unimproved (Card: 001 of 001) Unimproved Parcel 00 - Unimproved Extra Features (Card: 001 of 001) Line �_��Description _ � ear ;Units _ Value No Extra Features Sales History- See All 6 sales Previous Owner: DUNE FL LAND I SUB LLC - Month/YearjBook/Page� Type �� ��� DOR—CodeC---{ ondition{Amount � 12/2017 9649 / 096� Warranty Deed ��� 05 l Vacant��Multi-Parcel Sale � 05/2017 j9535 / 0546 ��_ Certificate ofTitle �� _05 �Vacant Multi-Parcel Sale 11/2016 �9462 / 0384 jMineral Rights or Royalty Transfer� 05 � Vacant Multi-Parcel Sale http://search.pascopa.com/parcel.aspx?parce1=2126050080007000040 2/23/2018 D.R. Horton-6912 Silverado Ranch Blvd.:3,153 sq ft �,�°;-... - �' � o umn ' SQ. FEET PRICE MAIN OR LIVING: 3,153 $ 112.65 OTHER AREA UNDER ROOF: -_ "$ 88.00 OTHER: - $ - VALUATION $ 355,185.45 FEE SHEET $ 1,256.00 ADDRESS $ 40.00 .- DRIVEWAY $ 40.00 BUILDING: $ 1,361.12 ELECTRICAL: $ 282.60 PLUMBING: $ 188.40 MECHANICAL: $ 131.88 SUB-TOTAL $ 1,964.00 TOTAL $ 1,964.00 SEW ER: n/a WATER: n/a IRRIGATION: $ - TOTAL: $ - WATER METER: n/a IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 ' FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 2,517.35 PARK IMPACT FEES $ 769.56 SIF'S: $ 4,828.00 100.0% $ 4,828.00 1.0% $ 48.28 TOTAL: $ 4,876.28 � T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 11,795.19 8'13-780-0020 City of Zephyrl�ills Permit Application Fax-813-780-0021 • Building Department. Date Received ������,����e��� �, �,_, ��y G��, d,¢��'��a�y �-r-�--�-r-�--�_ Phone Contact for Permitting __ r Owner's Name �, � �;- a � � Owner Phone Number � .�L�G�'. � �,?�, � Owner's Address ��������� �� �rs--� ,� �� '`�'2') ' , � T�'��i'°��J� � / Owner Phone Number ' - Fee Simple Titleholder Name ` �r�. �� Owner Phone NumLier Fee Simple Titleholder Address JOB ADDRESS ��C I Z � ���� - � y/�C�� V ' ,� � v , � � �-.���� LOT# -// . SUBDIVISION J �i 1 L�'Gr'G �� PARCEL ID# �> ''�-f.�' ,'���-� � J.-L�'� ��--��(,� e� (OBTAINED FROM PRbPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR e ADD/ALT �� 51GN � � DEMOLISH ' 'INSTALL REPAIR PROPOSED USE �f SFR � COMM � OTHER TYPE OF CO.NSTRUCTION ��' BLOCK . 0 FRAME � STEEL � DESCRIPTION OF WOqf( O`��t'� ���/�(.c•�'�ry�) � ,�Se.� � p� I ��,�zr � � 1 n �J C c. J ���:'1-I-1/� .���-Y,�. BUILDING SIZE SQ FOOTAGE ��� ' HEIGHT "�-r-rr-T-�-rre-�-r-T-r-�r-�-r-r-r-P-o--t-_r-Q�--rp'-r--r-o-e-r-e-n--�--rrrvp--r-s-re��-P-y--r-rr�-o--e-Q-�-o--u-ra-e-�-Q-a�- `�BUILDING � � I�. �r,;=t; VALUATION OF TOTAL CONSTRUCTION � i . �ELECTRICAL $ .- AMP SERVICE �,� �� � 0 PROGRESS ENERGY � W R.E.C. �PLUMBING � s � � - �') �MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION ��,��: -�f � 3 �� �GAS �� ROOFING � SPECIALTY � OTHER ' FINISHED FLOOR ELEVATIONS ' j�� C�,��r FLOOD ZONE AREA �YES NO t --F--C-4--G--0-F--k�-F-F-�F-�6-F�-0-8-{--Q-i-7-�-&-C--6--9-C�--9--G--C-v-F-�-G-9--�-t " �- �—a—�--9--�--a—a—s�,—a—o—:—e--z—�aaa�—r-a—.9.—e—a—e..,e� BUILDER SIGNATURE � � -''� COMPANY �.. � _ �-, ���-�.,,,.-� �"J,L� REGISTEFIED Y/ N FEE CURREA Y/N Address ����v� /_��<C�.ry7 .[� r^ lGia� c.. ' � License# ���G��'�� � ;� �LECTRICIA�V' �� ,�/�'' COMPANY � ��'• � ��- -� SIGNATURE �''"z'�'�'' �`� G' ,l?�C�n 7,.�",�',,�p � 'r'°4; ,�,� �: , RE�ISTEFIED Y/ N F.EE CURRE� Y/N Address � 4°�.�y QJ��'�,p�',/'`�E'i' �� � � �,f License# (,�. �`` , ��.�Q�<:J ��� PLUMBER ,� p / � � SIGNATURE � �""��..__�— COMPANY � ��..�'"�M.7.�` •.�A',�•G'�,��:�-,i�..�u �,��AJ'r�,F�,� REGISTERED Y/ N FEE CURRE� Y/N Address f f��� mrl,r''na�(�'cr `ir��.���,� T°^,.: F_ ' `—� `" License# ��k�'�' � ,,/r�. �� MECHANICAL -� , �^a' �:.'.,..-:^G../ COMPANY �A~��,.i}��'"�,l`��Al�' r � ��e�.?.JJ"� SIGNA7URE � . �m� , �i ",�'- � ., �, �RE�ISTERED Y�'/ N FEE CURREA Y/N Address ���-7� ��-�'"��.� �x� f'e�c�n,..a��,,�x'J',.�� , ' j License�# ��i������� �' OTHER ' SIGNATURE � �... ,--..-.. .- COMPANY 1.`aA�����,�1�,�.��,/.�/?�;=,.� � � REGISTERED Y/ N � . ����� � p �- FEE CURRE� Y/N �` Address I��,��.7,,�/�r�3 rG,� 1 , � � ,cJ�r,-... � � `�"�" �7� ' �'� License# IIIIIIIIIIIIIi1111110111L11111i111aaL911011111111L .pp10l09009lpaplp0 RESIDENTIAL Attach (2) Plot Plans; (2)sets of Building Plans; (1)set bf Energy Forms; R-O-W Permit.for new construction, Minimum ten (10)working days after submittal date. Required onsite,Construction Pians,Stormwater Plans w/Siit Fence installed, Sanitary Facilities&1 dumpster;Site Work�Permit for subdivfsfons/large projects COMMERCIAL Attach (2)complete sets of Building Plans plus a Life Safety Page; (1)set of Energy Forms. R-O-W Permit for new construction. Mlnimum ten (70)wor!<ing days after submittal date. Required onsite, Construction Plans,Stormwater Pians w/Silt Fence installe.d, : Sanitary Facilities &1 dumpster Site Vliork Permit for all new proJects.All commercial requirements must meet compliance SIGN PERMIT Attach (2)sets of Engineered Plans. � ''***PROPER7Y•SURVEY required for all NEW construction. Directions: Ffl�l o�ut appllcat��om�te���--�o-L,1-.p_.o_p--6-�_��e-��6-�-8-�-9-A_s�e`9--&--�c-�-.B-4-�.¢�-9-p�-fimp�-9_@�9.�a-�..tt-�-. Owner�Contractor sfgn back of application, notarized If over$25D0,a Notice of Commencement is required. (A/C upgrades over$7500) "` Agent(for tfie contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same �VER THE COUNTER PEAMI7TING • �eroofs If shingles Sewers (copy of contract required) :Service Upgrades A/C Fences (Plot/Survey/Footage) _ � Driveways-Not over Counter if on;�ublic roadways,.needs ROW � , � - . . __ I V�OTICE OF �D�ED RES1'�iICTI(7PJS: 7he undersigned understands that this permif may be subjec�i to "deed" r�strictions" which may be more restrictive than County regulations. The undersigned assumes resp�nsibility for campEiance with any applicable deed restrictions. UNLICEPISED COhlTRAC'CORS AND CONTRACTOR RESPONSIBILITIES• !f the awner has hired a contractar or contractars to undertake work, they may be required to be iicensed in accardance with state and local regulations. If the cantractor is not licensed as required by law, both the owner and cantractor may be cited �for a misdemeanor violatian ' under state law. If the owner ar intended contractor are uncertain as ta what licensing requirements may apply fiar the intended work, they are advised to contact the Pasco Caunty Building Inspection Qivision—Licensing Section at 727-847- BQ09. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor{s) sign partions ofi fne "contractor Biock" of this applicafian for which they will be respansible. lf you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges�in Pasco County. TR�4IVSPORTATIO�! If1�PACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEI�S: The undersigned.understands that Transpartation (mpact Fees and Ftecourse Recovery Fees may apply to the canstrt�ction of new buildings, change of � use in existing buildings, ar expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned a(sa understands, that such fees, as may be due, will be identified at the time o# permitting. 1t is f�rther understood that Transportatian Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or . fi�al power re€ease, the fees must be paid prior ta perr�7it issuance. Furthermore, if Pasco County WaterlSevver Impact fees are due, they must be paid priorta permit issuance in accardance with applicable Pasco County ordinances. CO�lSTRUCT00N L.tE�! i_AW (Ch�gter 7i3, Florida Statutes, as amended}: lf valuation af v�ark is $2,5Q0 00 or more, 1 certify that I, the applicant, have been provided with a capy of the "�lorida Constructian Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. ff the applicant is someone other fihan the�`owner", 1 ee�Eify Ehat 1 Y�ave abtained a copy of the above described dacument ar�d promise in good faith to deliver it to the "owne�' prior to commencement. � CONTRACTOR'S/4�1111NCR'S A�FiDAVlT. 1 certify that a!1 the infarmatian in this application is accurate and that ail wark wi�l be done in compiiance with a(( applicable (aws regulating construction, zoning and(and deve(opment. Appiicatian is hereby made fo obtain a permit to do work and installation as indicated. I certify that no work ar installation has commenced prior ta issuance of a permit and that all wark will be performed to meet standards af ail laws regulating construction, County and City codes, zoning regulations, and land development regulations in the �jurisdictian. I also cer�ify that 1 under�tand that the regulatians a#other government agencies may apply to the intended work, and that it is my responsibility ta identify what actions I must take to be in compliance. �uch agencies include but are not limited to': - DeparCment ofi Enviranmental Protection-Cyprsss Sayheads, Wetland Areas and Environmentally Sensitive Lands,WaterNVastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetiand Areas, Altering Watercaurses , - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. ' - C?epartment of Health & Rehabiiitative Services(Environmental Hea{th Unit-1Nelfs, Wastewater Treatment,. �eptic Tanks. - US-Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authorit}t-Ftunways. I understand that the following restrictions apply to the use of fiill - Use of fil! is not allowed in Flood Zone"V° unless expressly permitted - If the fili material is ta be used in Flood Zone "A", it is understood that a drainage .plan addressing a "compensating volume" will be submitted at time of permitting which is prepar�d by a professional enginee'r . licensed by the State af Flarida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall canstruction, i certify that fill will be used only ta fiil the area within the stem wall. - If fill material is to be used in any area, I cerCify that use of such fill will not adversely affect adjacent properties. If use of fill is found to advers�ly affect adjacent properties, the owner rriay be cited for violating ' the conditions ofi the building permit issued under the attached permit application, for (ots iess than ane (1) acre which are elevated by fill, an engineered drainage plan is required. If 1 am the AG�fl�'�' F�R TF4� QUUt�Ef�, 1 pramise in good faith ta inforrn the owner of the permitting canditians set forth in this affidavit prior to cammencing construction. I understand that a separate permit may be.required for electrical work, plumbing, signs, wells, pools, air conditianing, gas, or other instaliations not specificalfy inciuded in the application. A ' perrnit issued shai( be construed ta be a license to proceed with the wark and not as authority ta violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official frQm thereafter requiring a carrection of errars in pSans, constructian or violatians of any codes Every permit issued shall became invalid unless the work authorized by such permit is commenced within six months af permit issuance, or if work authorized by the perinit is suspended or abandoned for a period;of six (6) months after the time the work is cartzmenced. An extension may be requested, in writing, from the 8uilding Official for a period not to exceed ninety (90} days and wili demonstrate • justifiable cause far the extension. If work ceases for ninety (90) consecutive days,the job is considered abandoned. WARNI�I(a �"� CDWB�I�Fd: 1(OUFi �AIL'URE 70 RECORD A IVOTICE C1F CCJMMENCEMENT IllIAY RESUL7 IN YOUR PAYING TWIG� FOR tMPROV�MENTS TD Yt�UR PROP�RTY. !F YOU INTEND TiJ CiBTA1N FIiVARlC1NG, CUNSULT WiTN YOUR LENDER OR AN ATTORN�Y BEFORE RECORDING YOUR NOTICE OF CCIMMENCEMENT. FLORIDA JURAT(F.S. 117 03) � OWNEA OR AGEPIT_ j(���� CQNTRAC70R S bscr E�and sw4C,n, to (or affirmed)before me this Subscribed and sworn to(or affirmed) before me thls ;��� t t by _l.� C c-r'x���-�"��«.e.:�.�r::.`�.�� by , Who is/are o�or�aU,y -nown to me or has/haveproduced Who islare personally known to me or has/have produced as fdentification. as identfficatlon. . � � : �=-;�/� . . � �atary Publlc Notary Publlc ' Commission No � �� ' � Commissian No. '''�` � Name of Notary ty ed printed�r s�tam ed Name of NoYary typed,printed or stamped ��� Notery Public 5tate of Ftorida . . Michelle Moyes , Q My Gommissinn GG 057321 �q�,ptl� Explcasl2t21!?020 Single Family Dwelling Plan Review Comments 1. F.F.E. shall be a minimum of 8" above the road elevation and an engineered site plan. 2. Lots shall be graded to comply with R401.3 of the F.B.C. 3. Compaction test required if 24" or more of fill dirt is brought in at any one place. 4. Tie in survey required before pouring concrete. 5. Driveways require a R.O.W. use permit. A114 sides of driveway thru the sidewalk shall have expansion material. 6. All setbacks shall be met. 7. All property markers shall be uncovered and marked at time of first inspection. 8. All A.D.A. requirements shall be met. 9. No electric, plumbing, mechanical, or framing shall be covered without an inspection and approval first. 10. All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation). 11. Appliances shall not be installed in a location where subject to mechanical damage unless protected by approved barriers. M303.4 of the F.B.0 12. Water heaters shall comply with section P607.3 of the F.B.C. 13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M1308.1 14. Return air in all bedrooms. F.B.C. M1620.4 15. Smoke detectors are to be installed in accordance with R313.1 of the F.B.C. 16. All glazing requirements are to be in accordance with R308.4 of the F.B.C. 17. All means of egress are to be in accordance with R311 of the F.B.C. 18. "Green gypsum board" shall not be used as a backer in showers or tubs. R702.4.2 F.B.C. 19. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating or appliances or an attached garage. They shall be installed in accordance with the F.B.C. 21. All plumbing,mechanical, and electrical shall be separate from unit to unit. This includes all underground plumbing and electric. 22. All 2008 N.E.C. Codes will be enforced. 23. Tamper-Resistant Receptacles in accordance with 406.11 of the 2008 N.E.0 24. In accordance with the Land Development Code, lots shall be sodded before final at least 10 feet around the structure. 25.A cony of the ener�v cacls sl:all be with ves•fnit at all tinies. 26. Conv of final insulation report shall be vrovided with permit before�na� F.F.E.-Finished Floor Elevation F.B.C- Florida Building Code 5�'Edition R.O.W.-Right of Way A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2008) ' . ` PLOT PLAN DESCRIPTION:(AS FURNISHED) ' LOT 4, BLOCK 7 SILVERADO RANCH SUBDIVISION PHASE 6, 8 & 9A NOT YET RECORDED IN PLAT BOOK ----, PAGE(S) ----, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. Curve Table - Curve� Length Radius Delta Chord Bearing Chord C7 58.10' 2060.OD' 136'58' N16'32'03'W 58.10' ' C2 54.58' 1935.00� 1'36�58' S76'32'03'E 54.56� C3 139.33' 2100.OD' 3'4B'O5' S1737'37'E 139.30' C4 59.22' 2100.00' 136�57' S76'32'04'E 59.22' � � CS 80.10' 2100.00' 2'11'OB' S1826'O6'E 80.10' � � 0 z 1" = 30' GRAPHIC SCALE ,�p�t 31 Co���11� �Z!3 0 15 30 ZEPN�CO\MP F`Npp�E g5 � tJ T g00K O � �p P�' 125•� � �° y.c CRp01P0�R\N�� i� ��`C�,�� ``Y �REFEREN16,rZG' � � i qA.9' o��a N�4� ��" � c� ���'= a � ry �� � �o� r �' "�Z-�o � �/ 36'�, _ 9 N O O�` y{�'i ��. 1 0 l._: \24 ��, 426"1� o ���� \ u� Z-C PI i - 2. o \ \ \' ...� �T � b �� i � �p"+•..'O LZ>yF � � n i U OPR� � \ 'W �`. y�TAy p J �l � B� �p1,P� \ � \\ ".4.0. o �'^��o �.;.� � � 0^,� N oo qy.9� ,,.rs.> � . , yp w A � h \ . . . •.;'.; �c� 'o i ,��:, l ..C',�r . \: .c a o , ^p. . .�:: a�m � � � � �. \. .,�••o � � i r '� - ����:�•' p0a� � ��w 5.0� � � � �: � �2 � �� � � � •�+�'�-'= �� Y�Q 'a . ,L4 4 ��. � '��+t w , \ ��o \ �` " �2 3gp�� . � 2 \ � ��5� �2p '�'� CRp �'��.i1,( 7 O� � ' •9y 8�0 O�y w\�����5�239pOW/';. �a� � �' \ ��o G � r yL "�� ON LOT CALCULATIONS Q �� LOT = 7,043 SQ. FT. UVING AREA = 1,104 SQ. FT. GARAGE = 437 SQ. FT. ENTRY = 115 SQ. FT. LANAI = 0 SQ. FT. EZRA LOFT PLACE sTooP = s SQ. FT. TRAC7 "G" - 60' RIGHT OF Wqy DRIVEWAY = 560 SQ. FT. - (PRIVATE ROADWqY) A/C PAD = 12 SQ. FT. P� WALKWAY = 30 SQ. FT. CENTERLINE OF� IMPERVIOUS = 32%. RIGHi-OF-Wpy = 2267 SQ. FT. \ SOD = 4,776 SQ. FT. OFF LOT CALCULATIONS PREPARED FOR: A�, RIGHT OF WAY = 1490 SQ. FT. �2� DRIVE APRON = 133 SQ. FT. D•RHORli)N'�,Y;` � oG PUBLIC S/W = 468 SQ. FT. � 'tlGNf+C�Li i�uf't G' \90 TODTALS = 889 SQ. FT. �'� AREA = 8,533 SQ. FT. BUILDING SETBACKS �RivEwnY = sss S0. FT. FRONT: 22' SIDEWALK = 498 SQ. FT. REAR: 15' SOD = 5,665 SQ. FT. SIDE. 7.5' SIDE STREET: 20' LEGEND: NOTES. ` — — — BUILDING SEiBACK LINE PI POINT OF INTERSECTION PC POINT OF CURVA7URE 7. ELEVA710NS SHOWN ARE PER LOT GRADING - - - CEN7ERUNE p7 POINT OF TANGENCY PLANS PROVIDED BY THE CLIENT. - - - - RIGHi oF WAY uNE RP RnDIUs PoiN7 2. ELEVA710NS ARE BASED ON NAVD 1988 XX.XX pROPOSED ELEVATION PRC POINT OF REVERSE CURVATURE DATUM. — PCC POINT OF COMPOUND CURVANRE T'P TPICAL � PROPOSED DRAINAGE FLOW CS CONCRE7E SLAB THIS PLOT PLAN IS INTENDED FOR PERMITTING PURPOSES � CONCRE7E �P� P� P�T � ONLY. THIS IS NOT INTENDED FOR THE CONSTRUCTION OF (C) CnLCULq7ED THE PROPOSED HOUSE. REFER TO HOUSE PLAN AND A/� AIR CONDI710NER PB PLaT BooK OPTION LIST FOR CONSTRUCTION. ALL BUILDING SET BACK S/W SiDEWAuc PGS PAGES S0. FT. SQUARE FEET LINES SHOWN HEREON IS PER DATA FURNISHED BY CLIENT F.E.M.A. FEDERAL EMERGENCY MANAGEMENT AGENCY AND IS FOR INFORMATIONAL PURPOSES ONLY F.I.R.M. FLOOD INSURANCE RAIE MAP NAVD NORTH AMERICAN bERTICAL DANM THIS IS NOT A SURVEY NGVD NATIONAL GEODETIC VERTICAL DANM D&UE DRAINAGE& UTILITY EASEMENi THIS IS A PLOT PLAN ONLY PDE PRIVATE DRAINAGE EASEMENT UE UTILITY EASEMENT(PUBLIC) FLOOD NOTE: SURVEYOR NOTES: I HAVE EXAMINED THE F.I.R.M. MAP N0. 721o1CO288F, 1. THE SURVEYOR HAS NOT'ABSTRACTED THE DAlED SEPTEMBER 26, 2014, AND FOUND THE SUBJECT PROPERTY LAND SHOWN HEREON FOR EASEMENTS, RIGHT APPEARS TO LIE IN ZONE'X', AREAS DETERMINED TO BE OUTSIDE THE OF WAY, RESTRICTIONS OF RECORD WHICH 0.2R ANNUAL CHANCE FLOODPLAIN. THE SURVEYOR IAAKES NO MAY AFFECT THE TITLE OR USE OF THE LAND. GUARANTEES AS TO THE ABOVE INFORMATION. PLEASE�CONTACT THE LOCAL F.E.M.A. AGENT FOR VERIFlCATION. � 2. NO UNDERGROUND IMPROVEMENTS HAVE BEEN BEARING BASIS: � LOCATED EXCEPT AS SHOWN. BEARINGS SHOWN HEREON ARE BASED ON THE NORTHERLY IJNE OF 3. NOT VALID WITHOUT THE AUTHENTIC Lo7 4, BLOCK 7 BEING N74'16'26'E, PER PLA7. • ELECTRONIC SIGNATURE AND THE AUTHEN7IC A M E R 1 CA N ELECTRONIC SEAL OF A FLORIDA LICENSED (FIELDDATE:) REVISED: SURVEYOR AND MAPPER. - SURVEYING ' SCALE: 1'= 30 FEET ,�;::w,� ' 8c MAPPING INC. ''�`"�'•� �'°'°'��°�"""""�'`�'^ APPROVEDBY� JB ��g °".°mw""wea"""`°'n'""w" swMnaa'aanoi�s.w. CERTIFlCATION OF AU7HORIZATION NUMBER LB�6393 x�e^w�=������a�mno-.m<�,�,s 3191 MAGUIRE BOULEVARD, SUITE 200 .�r''� '0a�'10j'0J1P1a'"�°°" FOR �^v 16 , JOB NO. »�D73 LOT 4, BLK 7 ORLANDO, FLORIDA 32803 '�•��`"""��.� TME ^ FlRN f DanwNaY: DSB WWW,qMERICANSURVEYINGANDMAPPING.COM JAMES W. BOLEMAN PSM# 6485 DA7E PLOT PLAN 10 25 17 KAB , � FORM R405-20:14 FLORIDA ENERGY EFFICIENlCY CODE FOR BUILDING CONSTRUCTION ' - - Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Hayden 4EHB Elev D . Builder Name: DRH 6cpress Homes / St�et: P �Lj�P/y��' l n��l J +l'�:I.`��r� � PerrriitOffice: �''�`�..e/ � ��.r�l-+u�� Cit ,State,Zi Ze fi rhi Is,`FLL� �� Permit Number: � �37 Z Owner: 4I X Jurisdiction: (o[C60b Design Location: FL,Tampa �'1 � County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(2614.2 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood, Exterior R=11.0 1285.30 ftz b.Concrete Block-Int Insul,Exterior R=4 1 996.67 ftz 3. Number of units,if multipie family 1 c.Frame-Wood,Adjacent R=11.0 332.22 ft2 4. Number of Bedrooms 5 d.N/A R= ftz , 10.Ceiling Types (1541.0 sqft.) insulation Area 5. Is this a worst case? No a.Under Attic(Vented) R=30.0 1541.00 ftz 6. Conditioned floor area above grade(ftz) 2605 b.N/A R= ftz Conditioned floor area below grade(ft2) 0 c.N/A R= ftz ' 11.Ducts R ft2 I 7. Windows(250.0 sqft.) Description Area a.Sup:Attic, Ret:2nd Floor,AH:2nd Floor 6 261 a. U-Factor: Dbl,U=0.34 210.00 ftz " SHGC: SHGC=0.31 b. U=Factor: Dbl,U=0.55 40.00 ftz 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.34 a.Central Unit 40.0 SEER:14.00 c. U-Factor: N/A ftz SHGC• " 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ftz a.Electric Heat Pump 41.0 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 1.692 ft. Area Weighted Average SHGC: 0.315 14.Hot water systems a. Electric Cap:50 gallons S. Floor Types (1541.0 sqft.) Insulation Area a.Slab-On-Grade Ed e Insulation R=0.0 1104.00 ftz EF.0.950 9 b. Conservation features b. Raised Floor R=19.0 437.00 ftz None c.N/A R= ftz 15.Credits Pstat Total Proposed Modified Loads: 78.62 n A�� Glass/Floor Area: 0.096 Total Baseline Loads: 79.15 �� f1 I hereby certify that the plans and specifications covered by Review of the plans and �.�'�IiE37',��,� this caiculation are in compliance with the Florida Energy specifications covered by this = � p �i'% z°;` ,rt� Code. calculation indicates compliance � �,,, � -_ ,,.� �, lW. %Prip•'�'4` 0 with the Florida Energy Code. ti ffrr ,, `=;.,„ , ti, � ' PREPARED BY: �'Vfl�-�.,�,�... Before construction is completed " "' ..� _ DATE: io-3n-n this buildin will be ins ected for � �'�'�`� ,,.. 9 P t� �y�� ,d compliance with Section 553.908 * �' n ,� I hereby certify that this building, as designed,is in compliance Florida Statutes. .� ���,5 with the Florida Energy Code. D�� _ OWNER/AGENT: r�'�� ' � - BUILDING OFFICIAL: I DATE: J(����-- • � DATE: - � , - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as I certified factory-sealed in accordance with R403.2,2.1. . -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with Section 803 of RESNET Standards, is not greater than 0.060 Qn for whole house. 10/30/2017 12:34 PM EnergyGaugeC�USA-FlaRes2014 Section R405.4 1 Compliant Software Page 1 of 5 - � � > I � I FORM R405-2014 � �Lt�RIDA ENEI�G� EFi�iC1ERICY C��E �C�R IBUI��i�9G C��Si'RUC1'��� Florida Department af Business and Professional Regulatior� - Residentia! Performance Method' '� � I . � � Project Name: Nayden 4EHB Elev d . Bui{der Name: DRH Express Names Street: 'C"�(,�� `�. i� .. ,'�1 � 7i'k;�� ���'� ' 1 Permit Office: . City,State,Zip: �epfiyrhills`FLV�j��t � � '�,`U Permit Number: Owner: ��j X Jurisdiction: Design Locatian: FL,Tampa '"l�� Counry:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(2614.2 sqft.) lnsulation Area 2. Sirigle family or rr�uliiple family Single-fami2y a.Frame-Wood, E�cteriar R=1 f.0 2285:3Q ftz b.Concreta B(ock-(nt Insu(,Exteriar R=4.1 996.67 ft2 - - 3. Number of units,if multiple family 1 -- c. Frame-Wood,Adjacent R=11.0 332.22 ft� 4. Number of 8edroams - 5 d.N!A �, ftz 5. Is this a worst case? No 10.Ceiiing Types (1541.0 sqft.) Insula#ion Area a.Under Attic(Vented) R=30.0 1541.00 ft� 6. G�nditianed floar area above grade(ft2) 2605 b.NlA R= - ft2 Conditioned floor area below grade(ft�) 0 c.N/A R= ft2 11. Ducts R ftz 7. Windaws{250.0 sqft.} Descriptian Area a.Sup:Attic,Ref:2nd Floor,AH:Znd F1oar 6 261 a. U-Factor: Dbl,U=0.34 210.00 ft2 SHGC: SHGC=0.31 _ b. U-�actor: Dbl,tl=0.55 40.00 ft2 12.Gao2ing systems kBtuthr Efficiency SHGC: SHGC=0.34 a.Central Unit 40.0 SEER:14.00 c. tJ-Facior. NIA ft� SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Fector: N/A ftz a.Electric Heat Pump 41.0 HSPF:8.20 SNGG: Area Weighted Average Overhang Depth: 1 692 ft. Area Weighted Average SHGG: 0.315 14.Hot water systems a.E(ectric Gap:50 gal(ans 8. Floor Types (1541.0 sqft.} Insulation Area EF:0.95d a.Slab-On-Grade Edge Insulation R=0.0 1104.00 ft2 b. Conservation features b.Raised F1oor R=19.d 437.00 ft� Nane c.N/A R= ftz 15. Credi#s Pstat Tata( Praposed Modified Loads: 78.62 n A�� Glass/Floor Area: 0.096 Tota! Basefine Loads: 79.15 r/`i i hereby certify that the pians and spec'sficatians covered by Review of the ptans and ��'�k���q�,� this calculation are in compiiance with the Florida Energy specificatians covered by this = � p .y,� Y_;� Cade. calculation indicates compliance . � �«, '� ;;���,o� � with the Florida Ener �t Gade. , �• rr ;,;,`,°.._,;,�..° •�� 'Cc3 �J FtF=^ . .,.�'� R PREPARED BY: L'YII�._�Qh� Before construction is campleted F' `'' " ",` � __�- ;tti��.__.. O DATE: , �o-�o-n this building will be inspected far � � � ,�,, compliance with Section 553.908 * ��� � * I hereby certify that this building, as designed, is in compliance Flarida Statutes. � � �,� with the Florida Energy Code. �,T�'� OWNER/AGENT:�=''1��--�''�% '�-C%�•�•�''� -- BUILDING OFFICIAL: DATE: �!�1 t"Z f ) DATE: � �' � i - Compliance req�ites eertification by the air handler unit manufacturer that the air handler enclosure quatifies as � certified factory-sealed in accordance wi#h R403.2.2.i. ' -Compliance requires an.Air Barrier and Insulatian Inspection Checklist in accordance with R402.4.1.1 and an envelope leakase test repo�t in accardance with R402.4.1.2. � � - Compliance vuith a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to ou,�doors, tested in accordance with Section 803 of RESNEI'Standards,is not greater than 0.06Q Qn for whole hause. 10/30/201712:34 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Soflware � Page 1 af 5 , ' FORM R405-2014 _ , ' PROJECT , Title: Hayden 4EHB Elev D Bedrooms: 5 _ Address Type: Lot Information � Building Type: User Conditioned Area: 2605 Lot# 4/7 Owner: Total Stories: 2 Block/SubDivision: Silverado Ranch #of Units: 1 Worst Case: No PlatBook: Builder Name: DRH Express Homes Rotate Angle: 270 Street: I Permit Office: Cross Ventilation: County• Pasco i Jurisdiction: Whole House Fan: City,State,Zip: Zephyrhills, �I Family Type: Single-family FL, I New/Existing: New(From Plans) �I Comment: Garage R Face W � CLIMATE / - IECC Design Temp Int Design l'emp Heating_ Design Daily Temp V Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Tampa FL TAMPA_INTERNATI 2 39 91 70 75 645.5 54 Medium - BLOCKS Number Name Area Volume � 1 Blockl 2605 21579.7 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfiIID Finished Cooled Heated 1 Main 1104 9571.7 Yes 1 1 1 Yes Yes Yes 2 2nd Floor 1501 12008 No 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio Main 152.8 ft 0 1104 ftz ____ 0.2 0 0.8 2 Raised Floor 2nd Floor ____ ____ . 437 ftz 19 0.5 0 0.5 - ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1723 ftz 0 ftz Dark 0.92 No 0.9 No 0 _.26.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC � 1 Full attic Vented 300 1541 ft2 Y N 1 Q/30/2017 12:34 PM EnergyGaugeC�U$A-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5 1 , FORM R405-2014 � � . ' � CEILING - # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type i . .-- 1 Under Attic(Vented) Main 30 Blown 40 ftz 0.11 Wood 2 Under Attic(Vented) 2nd Floor 30 Blown 1501 ftz 0.11 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 0 _ 1 N=>W Exterior Concrete Block-Int Insul Main 4.1 1 S 8 8 S 161.8 ftz 0 0.6 0 _2 W=>S Exterior Concrete Block-Int Insul Main 4.1 20 S 8 173.3 ftz 0 0.6 0 _3 S=>E Exterior Concrete Block-Int Insul Main 4.1 39 8 8 8 343.8 ft2 0 0.6 0 _4 E=>N Exterior Concrete Block-Int Insul Main 4.1 36 8 8 8 317.8 ftz 0 0.6 0 _5 N=>W Garage Frame-Wood Main 11 20 4 8 8 176.2 ftz 0.23 0.01 0 _6 W=>S Garage Frame-Wood Main 11 18 0 8 8 156.0 ft2 0.23 0.01 0 _7 N=>W Exterior Frame-Wood 2nd Floor 11 39 8 8 317.3 ftz 0.23 0.6 0 _ 8 W=>S Exterior Frame-Wood 2nd Floor 11 40 8 8 325.3 ftz 0.23 0.6 0 9 S=>E Exterior Frame-Wood 2nd FI or z _ 0 11 39 8 S 317.3 ft 0.23 0.6 0 � _10 E=>N Exterior Frame-Wood 2nd Floor 11 40 8 8 325.3 ftz 0.23 0.6 0 �- DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N=>W Insulated Main None .4 3 6 8 20 ftz , ' 2 N=>W Wood Main None .46 2 8 6 8 17.8 ftz ' WINDOWS Orientation shown is the entered orientation => chan ed to As Built rotated 270 de rees . / Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N=>W 1 Vinyl Low-E Double Yes 0.34 0.31 31.0 ftz 6 fY2 in 1 ft 0 in Drapes/blinds None 2 N=>W 1 Vinyl Low-E Double Yes 0.34 0.31 2.5 ftz 6 ft 2 in 0 ft 0 in Drapes/blinds None 3 S=>E 3 Vinyl Low-E Double Yes 0.34 0.31 46.5 ftz 1 ft 0 in 10 ft 6 in Drapes/blinds None 4 S=>E 3 Metal Low-E Double Yes 0.55 0.34 40.0 ft2 1 ft 0 in 1 ft 3 in Drapeslblinds None 5 N=>W 7 Vinyl Low-E Double Yes 0.34 0.31 6.0 ftz 1 ft 0 in 0 ft 6 in Drapes/blinds None 6 N=>W 7 Vinyl Low-E Double Yes 0.34 0.31 31.0 ftz 1 ft 0 in 2 ft 6 in Drapes/blinds None 7 S=>E 9 Vinyl Low-E Double Yes 0.34 0.31 62.0 ftz 1 ft 0 in 0 ft 6 iri Drapes/blinds None 8 N=>W 7 Vinyl Low-E Double Yes 0.34 0.31 31.0 ftz 1 ft 0 in 0 ft 6 in Drapes/blinds None GARAGE - # FloorArea Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 437.038 ft2 437.038 ft2 48.4 ft 8.67 ft 0 1 0/30/2017 1 2:34 PM, EnergyGauge@ USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 T � I FORM R405-2014 , . ' INFILTRATION # Scope •� Method SLA CFM 50 ELA EqLA ACH ACH`50 1 Wholehouse Proposed ACH(50) .000368 2517.6 138.21 259.93 .3402 7 � HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump None ySPF:8.2 41 kBtu/hr 1 sys#1 ' COOLING SYSTEM # System Type Subtype Efficiency �apacity Air Flow SHR Block Ducts 1 Central Unit None SEER:14 40 kBtu/hr 1200 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 50 gal 70 gal 120 deg None � SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 � DUCTS / ----Supply---- ----Retum---- Air CFM 25 CFM25 HYAC# \/ # Location R-Value Area Location Area Leakage Type Handler TOT OUT Qf�1 RLF Heat Cool � 1 Attic 6 261 ftz 2nd Floor 45 ftz Proposed Qn 2nd Floor ---cfm 156.3 cfm 0.06 0.60 1 1 _ TEMPERATURES ' Programable Thermostat:Y Ceiling Fans: - Coolin Jan Feb r 1Mar A r Ma rX�Jun Jul Au Se Oct Nov Dec Heatin9 Jan f Feb [X]Mar �APr f �May [ ]Jun 4�Jul f�Au9 f�SeP E�Oct �Nov �Dec Ventin Jan [ Feb [X]Ma� A r � Ma [ j Jun � Jul [ Au [ Se �X�Oct Nov Dec 10/30/2017 12:34 PM EnergyGaugeC�USA-FlaRes2014 Section R40�.4.1 Compliant Software Page 4 of 5 FORM R405-2014 Thermostat Schedule� HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 .J8 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66. 1 0/30/201 7 1 2:34 PM EnergyGauge�USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5 I i d FORM R405-2014 � ENERGY PERFORNiAIVCE LEVEL (EPL) � DISPL�4Y CARD � ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the EnergyPerformance Index, the more efficient the home. , Zephyrhills, FL, " ' 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Frame-Wood,Exterior R=11.0 1285.30 ftz b.Concrete Block-Int Insul, Exteriar R=4.1 996.67 ftz 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 332.22 ftz 4. Number of Bedrooms 5 d.N/A R= ft2 10.Ceiling Types Insulation Area 5. Is this a worst case? No a.Under Attio(Vented) R=30.0 1541.00 ftz 6. Conditioned floor area(ftz) 2605 b.N/A R= ftz c.N/A R= ftz 7 Windows" Description Area 11. Ducts - R ftz a. U-Factor: Dbl, U=0.34 210.00 ftz a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 261 SHGC: SHGC=0.31 b. U-Factor: Dbl, U=0.55 40.00 ftz SHGC: SHGC=0.34 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ftz a.Central Unit - 40.0 SEER:14.00 SHGC: d. U-Factor: N/A nZ 13.Heating systems kBtu/hr Efficiency SHGC: a. Electric Heat Pump 41.0 HSPF:8.20 Area Weighted Average Overhang Depth: 1.692 ft. Area Weighted Average SHGC: 0.315 8. Floor Types Insulation Area 14.Hot water systems a.Slab-On-Grade Edge Insulation R=0.0 1104.00 ft2 a. Electric Cap:50 gallons b.Raised Floor R=19.0 437.00 ftz EF•0.95 c.N/A R= ftz b. Conservation features .. None 15.Credits Pstat I certify that this home has compliecf with the Florida Energy Efficiency Code for Building .�HE ST Construction through the above energy saving features which will be installed (or exceeded) tio� _ `�T�o in this home before final inspection. Otherwise, a new EPL Display Card will be completed ��`,,,�'�•;� :=.,��,. '�„s, based on installed Code com liant features. ti ,rr '� " '''' � p � ta�i-,,� .��,�'`�tt�� � _ _ ;i, . Builder Signaturey/� ,� (�� Date: � ( ��� t� �.,��,�j`��.- �. ¢� Address of New Home:� � ' f�� , � ;�; City/FL Zip: , .� `", '� �. �, L' �,c�b���c��4 J ` " ��`�� `Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient , mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Builcling Commission's support staff. . **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 10/30/2017 12:34 PM EnergyGaugeC�USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 . Florida Department of Business and Professional Regulations ' Residential Whole Buildin Performance and Prescri tive Methods ADDRESS: Permit Number: Zephyrhills,FL, MANDATORY REQUIREMENTS See individual code sections for full details. � 401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy pertormance level(EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law [Section 553.9085, Florida Statues]requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix C. � R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.1 through R402.4.4. _ Q R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.The sealing methods between dissimilar materials shall allow for differential expansion and contraction. • R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table 402:4.1.1,as applicable to the method of construction. Where required by the code official,an approved third party shall inspect all components and verify compliance. • R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2,and 3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures, 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended _ infiltration control measures; ' 3.Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. O R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers and outdoor combustion air. O R402.4.3 Fenestration air leakage.Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm - per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400 or AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. O R402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential.All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. � R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. � R403.7.3 Heat pump supplementary heat(Mandatary). Heat pumps having supplementary electric-resistance heat shall have controls that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. � R403.2.2 Sealing(Mandatory)All ducts,air handlers,and filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post-construction or rough-in testing below. Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either an energy rater certified in accordance with Section 553.99,Florida Statutes,or as authorized by Florida Statutes,to be"substantially leak free"by either of the following: 1. Post-construction test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure.All register boots shall be taped or otherwise sealed during the test. 2. Rough-in test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25Pa)across the system,including the manufacturer's air handler enclosure.All registers shall be taped or otherwise sealed during the test.If the air handler is not installed at the time of the test,total leakage shall be less than or equal to 3 cfm (85 Umin)per 100 square feet(9.29 m2)of conditioned floor area. Exceptions: 1. The total leakage test is not required for ducts and air handlers located entirely within the building envelope. 2. Duct testing is not mandatory for buildings complying by Section R405 of this code. 10/30/2i117 12:34 PM EnergyGaugeC�USA-FlaRes2014 -Section R405.4.1 Com Page 1 of 3 FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) � ❑ R403.2.3 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. � ❑ R403.3 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fiuids above 105°F(41°C) or below 55°F(13°C)shall be insulated to a minimum of R-3., R403.3.1 Protection of piping insulation. - ❑ R403.4.1 Circulating hot water systems(Mandatory). Circulating hot water systems shall be provided with an automatic or readily - - accessible manual switch that can turn off the hot-water circulating pump when the system is not in use. ❑ R403.4.3 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets. Extemal heat traps shall consist of either a commerciaily available heat trap or a downward and upward bend of at least 3�/z inches(89 mm)in the hot water distribution line and cold water line located as close as possible to the storage tank. �• R403.4.4 Water heater efficiencies(Mandatory). ' � R403.4.4.1 Storage water heater temperature controls , . R403.4.4.1.7 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature setting range shall be from 100°F to 140°F(38°C to 60°C). � . R403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied ' to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s) of combustion types of service water heating systems to be turned off. p R403.4.4.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water heating category. Solar water heaters shall met the criteria Section R403.4 4.2.1. . R403.4.4.2.1 Solar water heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of � Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors, , and SRCC Standard TM-1,Solar pomestic Hot Water System and Component Test Protocol,Collectors in installed solar water heating systems should meet the following criteria: � 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and 2. Be installed at an orientation within 45 degrees of true south. � p R403.5 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code,Residential or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. p R403.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment. � R403.6.1 Equiptnent sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, - based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and �'i indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1.This code does not allow designer safety factors,provisions for future expansion or other factors which affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation I�� such as standard kitchen and bathroom exhaust systems. j • R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the �� calculated total load,but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.6,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load. T 10/30/2017 12:34 PM � EnergyGauge�USA-FlaRes2014 -Section R405.4.1 Com Page 2 of 3 FORM R405-2014 fVIAND.ATORY REQUIREMENTS - (Continued) 0 R403.6.1.1 Cooling equipment capacity.(continued) The published value for AHRI total capacity is a nominal,rating-test value and _ shall not be used for equipment sizing.Manufacture's expanded pertormance data shall be used.to select cooling-only equipment.This selection shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower cfm provided by.the expanded pertormance data, the design value for entering wet bulb temperature and the design value for entering dry bulb temperature. Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space. Exceptions: 1. Attached single-and muiti-family residentiai equipment sizing may be selected so that its cooling capacity is less than the _ calculated total sensible load but not less than 80 percent of that load. I2. When signed and sealed by a Florida-registered engineer,in attached single-and multi-family units,the capacity of equipment may be sized in accordance with good design practice. _ � R403.6.1.2 Heating equipment capacity _ ' R403.6.7.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section R403.6.1 '1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load. . R403.6.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design , requirements calculated according to the procedure selected in Section R403.6.1. , ' R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shail not be less than the design load calculated in accordance with Section R403.6.1 � R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: - 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum pertortnance during base load periods is utilized. ❑ R403.7 Systems'serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections �� C403 and C404 of the Commercial Provisions in lieu of Section R403. ❑ R403.8 Snow melt system controls(Mandatory). Snow and ice-melting systems,supplied through energy service to the building,shall include automatic controls capable of shutting off the system when the pavement temperature is above 55°F,and no precipitation is falling and an automatic or manual control that will aliow shutoff when the outdoor tem erature is above 40°F. P ❑ R403.9 Swimmin ools in round s as and ortable s as Mandato The ener re uiremen s 9 p � 9 P p p ( ry). gy q t for residential pools and ' inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSI/APSP-15.The energy ', requirements for portable spas shall be in accordance with ANSI/APSP-14. � Q R403.9.1 Pool and spa heaters. All pool heaters shail be equipped with a readily accessible on-off switch that is mounted outside the heater to allow shutting off the heater without adjusting the thermostat setting. � � R403_9.1.1 Gas and oil-fired pool and spa heaters. All gas-and oil-fired pool and space heaters shall have a minimum therrnal efficiency of 82 percent for heaters manufactured on or after April 16,2013 when tested in accordance with ANSI Z 21.56. , Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights. � R403.9.1.2 Heat pump poal heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verity procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. O R403.9.2 Time switches. Time switches or other control method that can automatically tum off and on heaters and pumps according to a preset schedule shall be installed on all heaters and pumps. Heaters,pumps and motors that have built in timers shall be deemed in compliance with this equipment. . • Exceptions: • 1. Where public health standards require 24-hour pump operations. 2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems. . 3. Where pumps are powered exclusively from on-site renewable generation. O R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Outdoor pools deriving over 70 percent of the energy for heating from site-recovered energy,such as a heat pump or _ , ' solar energy source computed over an operating season. - I ❑ RR404.1 Lighting equipment(Mandatory). A minimum of 75 percent of the lamps in permanently installed lighting fixtures shall be I high-efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps. Exception: Low-voltage lighting shall not be required to utilize high-efficacy lamps. � R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously buming pilot lights � R405.2 Pertormance ONLY. All ducts not entirel.y inside the building thermal envelope shall be insulated to a minimum of R-6. I O R405.2.1 Pertormance ONLY. Ceilings shall have minimum insulation of R-19.Where single assemby of the exposed deck and beam type or I concrete deck roofs do not have sufficent space,R-10 is allowed. I 10/30/2017 12:34 PM EnergyGaugeC�USA-FlaRes2014 -Section R405.4.1 Com Page 3 of 3 FORM R405-20.14 • TABLE 402.4.1.1 .. AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA �I Project Name: Hayden 4EHB Elev D Builder Name: DRH Express Homes Street: Permit Office: City,State,Zip: Zephyrhills, FL, Permit Number: Owner: Jurisdiction: Design Location: FL,Tampa COMPONENT . CRITERIA • CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. - - Ceiling/attiC The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shail be insulated and the junction of the foundation Walls and sill plate shall be sealed. I The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walis shall be sealed. Windows, skylights and doors - The space between window/door jambs and framing and skylights and framing shall be sealed. Rim 'oists Rim joists are insulated and include an air barrier. Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered fioors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation,insulation shall be permanentiy attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the availabie cavity s aces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting _ Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated,and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available - space shall extend beflind piping and wiring. Shower/tub on exterior wall Exterior walis adjacent to showers and tubs shail be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be , sealed to the sub-floor or drywall. � Fireplace An air barrier shail be installed on fireplace walls.Fireplaces shall have' gasketed doors � 10l30/2017 12:34 PM EnergyGauge�USA-FlaRes2014 Section R405.4 1 Compliant Software Page 1 of 1 � � FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTF�UCTION Envelope Leakage Test Report Prescriptive and Performance Method Project Name: Hayden 4EHB Elev D Builder Name: DRH Express Homes Street: Permit Office: City,State,Zip: Zephyrhills, FL, Permit Number: Design Location: FL,Tampa Jurisdiction: Cond.Floor Area:: 2605 sq.ft. Cond.Volume: 21580 cu ft. Envelope Leakage Test Results Leakage Characteristics Regressibn Data: C: n: R:� CFM(50): Single or Multi Point Test Data HOUSE PRESSURE FLOW: E�' 1 Pa � cfm EqLA: 2 Pa cfm ACH: 3 Pa cfm ACH(50): 4 Pa cfm 5 Pa cfm S�' 6 Pa cfm R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2,3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted tiy an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be pertormed at any time after creation of all penetrations of the buiiding thermal envelope. _ During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3.Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. I hereby certify that the above envelope leakage W here required by the code official, ��T���'q�,� performance results demonstrate compliance testing shall be conducted by an �„'y ,,, =�,, d�, with Florida Energy Code requirements in approved third party.A written � '��• ° '' ��`�„� accordance with Section R402.4.1.2. report of the results of the test shall h r��+l���";;:;:;j'��;.�'�� p .:,�..,_. � be signed by the third party �4:..._ .� p � !'it .a conducting the test and provided to * �4 * SIGNATURE: the code official. �� ��� PRINTED NAME: aD yy�� DATE: BUILDING OFFICIAL: DATE: 10/30/2017 12:34 PM EnergyGauge�USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 Duct Leakage Test Report Performance Method . � FLt�RIDA ENERGY EFF'tC1ENCY CODE FQR�BUILDING Ct)NSTRUCTIUN � Form R405 Duct Leakage Test Report Performance Method Project Name: Hayden 4EHB Elev D Builder Name: QRH Express Homes Street: Permit Office: � City,State,Zip: Zephyrhilis,FL, Permit Number: Design Locatian: FL,Tampa Jurisdiction: - Duc#Test iirrce: Post Construction Duct Leakage Test Results CFM25 Duct Leakage Test Values Line System Outside Duct Leakage 1 System 1 cfm25(Out} 2 System 2 cfm25(Out} 3 System 3 cfm25(Out) 4 System 4 cfm25(Out) 5 Tatai House Surrt lines 1-4 Duct System ����ag� Divide by (Total Conditioned F(oor Area) _ (Qn,Out) I certify the tested duct leakage to outside, Qn, is Duct tightness shall be verified by �"T���'.�T not greater than the proposed duct leakage Qn d _� � specified on Form R405-2014. testing#o Sectron 803 af the RESNET �}'`J'.,,fr� .��,:`,,fl�+ _ Standards by an energy rater certified in �a , `;�, .,� accordance with Section 553.99, ,.�ey�+ rr,�t'��r." "'����:�•" , o . 3=a _ • , ,';:•'l ' 4 •'�u....,. *Jd Florida Statutes. ��r_ �r v SIGNATURE: � u��� �, '�' *' S * � �� PRINTED NAME: ' �'p�j��� _ DATE: " BUILpING OFFICIAL: DATE: � � 10/30/2017 12:34 PM ` EnergyGauge(�1 USA-FlaRes2014 -Section R405.4.1 Compliant S Fage 1 of 1 .�. 9 � Manual S Compliance Report JOb' wri htsoft Date: Oct 10,2014 � Entire House 8,,: _ Progressive Air Systems, Inc . � 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 � • ' • � � For: DR Horton/Express _ Lot 4 Blk 7 Silverado Ranch, Zephyrhills, FL • � . • . Design Conditions ' Outdoor design DB: 91.2°F Sensible gain: 32055 Btuh Entering coil DB: 76.4°F Outdoor design WB: 77.1°F Latent gain: 4144 Btuh Entering coil WB: 63.2°F Indoor design DB: 75.0°F Total gain: 36199 Btuh Indoor RH: 50% Estimated airflow: 1367 cfm Manufacturer's Performance Data at Actual Design Conditions � Equipmenttype: SpIitASHP - Manufacturer: Carrier Model: CH14NB042`*`*A+F64CNP042 Actual airflow: 1367 cfm Sensible capacity: 32445 Btuh 101%of load Latent capacity: 6269 Btuh 151%of load , Total capacity: 38714 Btuh 107%of load SHR: 84% - . • • Design Conditions Outdoor design DB: 40.0°F Heat loss: 27149 Btuh Entering coil DB: 69.5°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB042**"'A+FB4CNP042 � Actual airflow: 1367 cfm Output capacity: 37299 Btuh 137% of load Capacity balance: 31 °F Supplemental heat required: 0 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 1367 cfm Output capacity: 8.6 kW 108%of load Temp. rise: 18 °F Meets are all requirements bf ACCA Manual S. _ �, � wrightsoft� Right-Suite�Universal 2017 17.0.21 RSU25554 2017-Oct-30 12:35:09 � Page 1 ..\Wrightsoft Flles\E�ress homes\Hayden-4EHB.rup Calc=MJ8 House faces: W ..� 9 � Load Short Form Job: W1'1 E'1tS0� Date: Oct y0,20y4 • Entire House By: , Progressive Air Systems, Inc ,. 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 � • ' � • For: DR HortoNExpress Lot 4 Blk 7 Silverado Ranch, Zephyrhills, FL � - � - • � . � ' . Htg Clg Infiltration Outside db(°F) 40 91 Method Simplified I Inside db (°� 70 75 Construction quality Semi-tight � Design TD (°F) 30 16 Fireplaces 0 � Daily range - L. Inside humidity (%) 50 50 Moisture difference (gr/Ib) 26 54 HEATING EQUIPMENT COOLING EQUIPMENT ' Make Carrier Make Carrier Trade CARRIER Trade CARRIER Model C H 14N B042"***A Cond C H 14N B042****A AHRI ref ^ Coil FB4CNP042 AHRI ref Efficiency 8 HSPF Efficiency 11.3 EER, 13.7 SEER Heating input Sensible cooling 30750 Btuh Heating output 38500 Btuh @ 47°F Latent cooling 10250 Btuh Temperature rise 26 °F Total cooling 41000 Btuh Actual air flow 1367 cfm Actual air flow 1367 cfm Air flow factor 0.050 cfm/Btuh Air flow factor 0.043 cfm/Btuh Static pressure 0.56 in H20 Static pressure 0.56 in H20 Space thermostat Load sensible heat ratio 0.89 Capacity balance point=31 °F Backup: In ut=9 kW, Out ut=29290 Btuh, 100 AFUE ROOM NAME Area Htg load Clg load Htg AVF Clg AVF , (ftz) (Btuh) (Btuh) (cfm) (cfm) kitchen/living 608 7370 8460 371 361 bed 2 164 2960 1938 149 83 � powder 59 968 367 49 16 flex 156 3106 3211 156 137 foyer 75 1443 917 73 39 stairs 44 0 0 0 0 bed4 181 1647 2131 83 91 bed3 - 184 1965 3356 • 99 143 wic 60 143 177 7 8 wic 2 32 706 911 36 39 ' m suite 277 2507 4064 126 173 bath 135 355 355 18 15 upstairs living 234 1366 2606 69 111 stairs 2 50 0 0 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. .� wri htsoft° 2017-Oct-3012:35:09 ^, 9. Right-Suite�Universal 2017 17.0.21 RSU25554 Page 1 � ...\Wrightsoft Files\E�ress homes\Hayden�EHB.rup Calc=MJB House faces: W , i bed5 175 1606 2088 81 89 laundry , 41 368 917 ' 19 39 a/c • - 19 0 0 0 0 bath 3 96 639 559 32 24 _. hall 63 0 . .. 0 0 0 Entire House d 2651 27149 32055 1367 1367 Other equip loads 0 0 Equip. @ 1.00 RSM - 32055 Latent cooling 4144 TOTALS 2651 27149 36199 1367 1367 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. .� wri htsoft° 2017-Oct-3012:35:09� �. 9 Right-Suiie�Universal 2017 17.0.21 RSU25554 Page 2 � \Wrightsoft Files\Express homes\Hayden-4EHB.rup Calc=MJS House}aces: W ` L I Pro'ect Summar Job: -�- wrightsoft� � � - Date: Oct 10,2014 � Ent�re House B,►: � Progressive Air Systems, Inc 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 i . � � � • For: DR Horton/Express Lot 4 Blk 7 Sifverado Ranch, Zephyrhills, FL Notes: - ' � - • • • Weather: Tampa Intl AP, FL, US - Winter Design Conditions Summer Design Conditions � Outside db 40 °F Outside db 91 °F Inside db 70 °F Inside db 75 °F Design TD __ 30 °F Design TD 16 °F I Daily range L Relative humidity 50 % Moisture difference 54 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 20520 Btuh Structure 23084 Btuh Ducts 6629 Btuh - Ducts 8971 Btuh Central vent(0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 27149 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 32055 Btuh Method simplitied Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 2674 Btuh Ducts 1469 Btuh Central vent (0 cfm) 0 Btuh Area fit Hea2t65g Cooling (none) ( 1 2651 Equipment latent load 4144 Btuh Volume2�ft3) 22094 22094 � Air changes/hour 0.22 0.11 Equipment total load 36199 Btuh Equiv.AVF (cfm) 81 41 Req. total capacity at 0.75 SHR 3.6 ton � Heating Equipment Summary - Cooling Equipment Summary Make Carrier Make Carrier ' Trade CARRIER _ Trade CARRIER Model CH14NB042**'"'A Cond CH14NB042****A `� - AWRrref Coil FB4CNP042 . AHRI ref Efficiency 8 HSPF Efficiency 11.3 EER, 13.7 SEER Heating input Sensible cooling 30750 Btuh Heating o.utput 38500 Btuh @ 47°� Latent cooling 10250 Btuh Temperature rise 26 °F Total cooling 41000 Btuh Actual air flow 1367 cfm Actual air flow 1367 cfm Air flow factor 0.050 cfm/Btuh Air flow factor 0.043 cfm/Btuh Static pressure 0.56 in H20 Static pressure 0.56� in H20 Space thermostat Load sensible heat ratio 0.89 Capacity balance point=31 °F Backup: � _ Input=9 kW, Output= 29290 Btuh, 100 AFUE � Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. .�. -�-wrightsoft 2017-Oct-30 12:35:09 I �� Right-Suite�Universal 2017 17.0.21 RSU25554 Page 1 ...\Wrightsoft Files\E�ress homes\Hayden-4EHB.rup Calc=MJ8 House taces: W ' � s FORM R405-2014 � RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION�CHECKLIST Florida Department of Business and Professional Regulafion Simulated Performance Alternative (Performance)Method � Applications for compliance wifh the 2014 Florida Building Code, Energy Conservation via the residential Simulated Pertormance method shall include ❑ This checklist ❑ A Form R405 report that documents that the Proposed Design complies with Section - R405.3 of the Florida Energy Code. This form shall include a summary page indicating home address, e-ratio and the pass or fail status along with summary areas and types of components, whether the home was simulated as a worst-case orientation, name and version of the compliance software tool, name of individual completing the compliance report(1 page)and an input summary checklist thaf can be used for field verification (usual/y 4 pages/may be greater). ❑ Energy Performance Level(EPL)Display Card(one page) ❑ Mandatory Requirements(three pages) Required prior to CO for the Performance Method: ❑ Air Barrier and lnsulation Inspecfion Component Criteria checklist(Table R402.4.i.i - one page) �. ❑ A completed Envelope Leakage Test Report(usually one page) - ❑ lf Form R405 ducf leakage type indicates anything other than "defau/t/eakage; then a comp/eted Form R405 Duct Leakage Test Report(usually one page) � EnergyGauge(�-USRCZB v5.1 ' 10/30/2017 12:41:37 PM Page 1 of 1 i - - ��,�::-----=_-~_,,. - - s� � �_ lPAS�6, �C{)lJ1�T�', �LC)l�IDA �,. Permit Na. � � z- Date Permitted 2.- —ZO YBuilder NametOwner Name C� �tizh+��JY� ��C.� Cantrol# Caunty Parcei No. C�c��~Z�--(}j)�p���'jD_OO�Za SubDfv: s�� AddressiLocation (. 2 cSi ���'t" t.�J � �� � ; ClassiflcattontType of Use cSi i�. � ;...:' . F:; TRANSPORTAI'ION{MPACT FEE Rate: Sq.Ft Unit: � �,3 {5' ��`�' Exempt �Yes [� No Houv Determtned �>: i°. : . ;�,-. tmpact Fee Amount $. �c�p L,�,Z, Zbns No. TAZ: !'�V SCHQdL iMPACT�EE t/ �`� Account {056) Singte-Family Aetached House Amount $ 7��` ��� i�%' (057) Mobile Hame {058} Other Reslden#ial �- 123) Collection Fee Exempt [�Yes � No How Determfned PARKS AND RECREATION FEE Land Accaunt Land Credit Land Total Recreatlon Accaun# Reoreation Cred(t �Recreation Total Zone TOTAL AMOUNT $ `�,�_ �� Exempt �Yes [� No How Determ#ned LfBRARY FEE Land Account Land Credit Land Total " Fac111ty Account Facillty Credit Facility Tatai � Exempt ❑Yes ❑ No tiow Determined Totai Amo "��~--- + RESOURCE FEE ERU TOTAL AMC?UNT ' P�epared By Checked By NO CER7IFIGATE 1?F OCCUPANCY WtLL BE ISSUED OR FINA�.INSBEGTiON � PERFQRMED UNTIL THE TCi7AL QMCiUNTS LtS7ED NAVE � BEEN PA1D AND �; RECE4PTED FO�t BY A CENTRAL PERMITi'ING Ci�FtCE OF PASCO COtfN"TY � Acknowledgement below does not Impty accaptance of concutreoce,but simply ceceipt of�e copy of thls form,pfaoing � the building permlt ownar an nottce of this assessmenk and th�cand{tions of paymeat for same. i � DATE RECEIVED BY RECEIPT NO. DATE. BY ' _ Pasco couNn ' �t DEVELOPMEi�7 SERViCES ° 8731 Citizens Drive Date:7/10/2018 P�SC - �- �UUNTS� .FLORIllA.; . New Port Richey,FL 34654 " Gicu:nnrPu�c:rs , ...:�Ura�Sr�c:E�_;_,__,,..,_: �•�• , �....,,.... .. , .�... ..< ... ,....._. �.,.Z2j.-84.7_,-2411...�. .. ,...,..�.....,...�.: ., ,..,. ... .,...... ..... ...... _., ... ..,... _. .,.,._.�..... ....., . . ,.:,. ... . .. ., .. ....... .....___ ...>.._:_.,:.,...�,:�,,__ . .: - . .......... _ ��� '�'�� �'...�����.'.i.,. �e� . . .. Receipt#: 1774501 FEE DESCRIPTION ACCOUNT CODE UNITS INVOICE# FEE AMOUNT PAID RECEIPT# DATE Impact Fee Res(dential Solld 24503100-329010 31.60 1362337 $31.60 $31.60 1774501 7/10/18 Waste Single Family TOTALS: $31.60 S31.60 Receiat# Paid Bv Check# CC Auth# Cashier Ib Workstation Receint Date Amt Paid 177450� Check 767929 548 BCCCP04W 07/10/2018 $31.60 Total Payments: $37.60 Pa or Address Phone DR Horton DRHotton 1341 Hortion Circle Arlinton TX 76011 Comments• City of Zephyrhills ��^ � 69'12 Silverado Ranch Blvd I � l 05-26-21-0080-0070-0�4D Whlle you wlll be paying you�blll wlth Pasco County�evelopmant Servims,the tuil amount of the credi[cafd or e-check fees,NOT shoWn above,Is coUeeted hy Fint BIIIIng payment servlees. i MyReports/reports/IPASCOPROD/PASCO/RaceiptPOS V6,rpt 7/10/2018 Page 1 of 1 � FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION ' Envelope Leakage Test Report ' . Prescriptive and Performance Method Project Name: SILVERADO Builder Name: D R HORTON Street: 6912 Silverado Ranch Blvd Permit Office: City,State,Zip: Zephyrhilis,FL 33541 Permit Number. Design Location: 6912 Silverado Ranch Blvd(Lot 4) Jurisdiction: Cond.FloorArea: 2613 Cond.Volume: 22024 Envelope Leakage Test Results Leakage Characteristics Regression Data: I C: n: R: CFM(50): 2103 Sin le or Multi Point Test Data ELA: 116 HOUSE PRESSURE FLOW: EqLA. 273 1 50 Pa 2103 cfm ACH: 5.73 2 0 Pa 0 cfm SLA: .04 3 0 Pa 0 cfm ACH(50)': 5.73 4 0 Pa 0 cfm `For prescriptive projects,tested leakage must be<=7 5 0 Pa 0 cfm ACH(50). For performance projects, tested leakage must be<=the ACH(50)shown on Form R405-2014 6 Pa cfm for this project. R402.4.1.2 Testing.The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zones 1 and 2.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Testing shall be conducted by either individuais as defined in Section 553.993(5)or(7),Florida Statutes or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration 3.Interior doors,if installed at the time of the test,shall be open; 4 Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be tumed off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. I hereby certify that the above envelope leakage pertormance results demonstrate compliance with Florida Energy Code requirements in accordance with Section R402.4.1.2. Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7), Florida Statutes o4K�1E5T,�T� or individuals licensed as set forth in Section ��'� r _=s��f 489.105 3 f, y�"�,�, ._ ��`@'`< ( )() (g),or(i)or an approved third party A ¢ ,�",.,,, ,`..�, ,� � written report of the results of the test shall be signed W � �'`�� � Digitally signed by Michael by the third party conducting the test and provided to � y�i�'� ��� siiberstein the code o�cial. Z�L � Date:2018.08.0819:49:36 EDT �f CN=Michael Silberstein,O=TopBuild +Y � Home Services,OU, .� �'OD{Y6'� EMAI LAD D R ESS=Mi chael.S il berstei SigI18tU�C: n@topbuild.com,C=US r_ Printed Name: Michael Silberstein BUILDING OFFIC L: Date: 08/08l2018 DATE: �� Thank you for allowing TopBuild the opportunity to provide the above services for you.Please feel free to contacl me with any questions. 10/25/2017 391935 � � � WEINTRAU� � INSPECTIONS &FORENSIC,INC. 3868 Sun City Center Blvd. Ph.813-633-8000 Sun City Center,Fl.33573 Fx.813-464-5026 CONCRETE SLAB/FDUNDATIDN INSPECTION REPORT INSPECTION DATE: OS/03/2018 (�j-- CLIENT/Community: D.RH-TAMPA/ Silverado LOT#(s /ADDRESS: # 4/7 / 19372 Silverado Ranch SUPERINTENDENT: Chris Tallant WEATHER: 66 sunny INSPECTION CRITERIA/PROTOCOL OBSERVED&INSPECTED PASS FAIL 1. Verify Soil Compaction Report in permit box(if req. by jurisdiction X 2. Ve�y slab thickness formed is per permitted plans X 3. Verify exterior wall footing excavation free of debri X 4. Verify exterior wall footing reinforcing steel size and quantity per plans X 5 Verify isolated or monolithic footing pad reinforcing steel size and quantity X are per plans 6. Verify isolated_or monolithic footing pad locations are per plans X Verify that all continuous interior monolithic thickened slab foundations are �' width and depth per plans X Verify that all continuous interior monolithic thickened slab foundations are g' correctly located per plans X 9 Verify slab welded wire reinforcing is gage and grid dimension specified on X plans . Verify that all welded wire slab reinforcing is lapped per plans or Code � 10. referenced standard whichever is greater X 11 Verify that all welded wire slab reinforcing is properly chaired each way at X 36"o/c 12. Verify vapor barrier is per plans for type and millage X 13. Verify vapor barrier is installed in accordance with manufacturer's X recommendations 14. Verify all seams are taped and conduit penetrations taped X r � �EINTRA�T� � INSPECTIONS &FORENSIC,INC. 3868 Sun City Center Blvd. Ph. 813-633-8000 Sun City Center,Fl.33573 Fx.813-464-8026 Verify isolation pipe chases installed at plumbing penetrations through X 15. footing two(2)pipe-sizes greater than penetrating pipe. 16. Verify that special arching reinforcing steel in footing is installed at pipe X penetrations per architectural detail Verify ufer-ground properly sleeved thru footing and Installed in accordance 17. with permitted plans and FBC;where attached to footing rebar eliminate X vapor barrier under footer for 20 foot length at connection Verify masonry wall dowel installation for size, placement,Location, X 1 g' clearances&size per permitted plans Comments: RESULTS INSPECTION ITEMS NOT CHECKED PAS,S AND FAIL INDICATES NOT APPLICABLE Pass (*)re-inspection required for failed inspections INSPECTED BY: Sean Cyr � Inspectors Name scyr@weintraubinspections.com ' Email address 813.853.4313 Phone# � �` �._ CITY OF j / j / BUtLDlNt'�t ZEPNYRHILLS DEPARTMENT . � QF ADDITIt�N t�R CC�RRECT1t�N ii � ' � qppR��, DATE PERMIT f > ��crc� �—(� —� '. .:� �' THIS J08 HAS N4T BEEN CONIPLETED. �he foliow.ing additions or correctians shal!be made before tha jab wil! be accepted. ' t �-�.+�, �.� �� S `�e�� - o�� t� �-� ,�4 �b �r � r .�c , ur -�( c� �t a- t'k�� ��`'' � � � �� � �Q � It is uniawtui tor any Carpentsr,Contractor,Buildar,or other persons,to AFTER CORREGTtONS ARE MADE CALL cuver or cause to be covered,any part ot the wark with flaoring,Iath,earth 78�_pp�0 FOR RE-tNSPECTiC?N or nther material,untii iha proper inspector has had ample time to approve the instaqaiion. OFFICE NOURS 7:30AM-4:30 PM MON.-FRi. iNSPECTOR -- —� 5335 -8TH STREEf {813}780-OQ20 � ` CERTIFICATE OF OCCUPANCY Address; 6912 SILVERADO RANCH BLVD C.twner: DR HORTQN INC ZEPHYRHlLLS, FL. 12602 TEl.ECOM DR Subdiv: SILVERADC? TEMPLE TERRACE FL 33637-4935 Parcel: 05-26-21-0080-007p0-p040 Work Type: 101-NEW CONST/SFR Cons#ruction Type: NUT APPL(CABLE ❑ Sprinklers Use Ciassification: NC?T APPLlCABLE Permit Number: '!9372 Date:�° � ���j j� / �� � fSSUED SUlLDt CJFFICIAL : WATER MUST BE CHANGED OVER 1NITNIN 10�DAYS OF ISSUANCE GARBAGE DEPOSIT MUST BE APPLIED FOR PRIOR TQ ISSUANCE _ � .