Loading...
HomeMy WebLinkAbout17-19006 CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 19006 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL PERMIT INFORMATION LOCATION INFORMATION Permit#:19006 Issued: 11/06/2017 Address: 6768 BASSWOOD CIRCLE Permit Type: GENERAL BUILDING PERMIT ZEPHYRHILLS, FL. Class of Work: 104-NEW CONST TRI 3/4 UNIT Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 95,000.00 Total Fees: 6,693.73 Subdivision: DRIFTWOOD Amount Paid: 5,316.88 Date Paid: 11/06/2017 Parcel Number: 02-26-21-0300-00000-0330 CONTRACTOR INFORMATION OWNER INFORMATION Name: RYMAN CONSTRUCTION OF FLORIDA IN, Name: RYMAN CONSTRUCTION INC Addr: 36413 S.R. 54 WEST Address: 36413 STATE ROAD 54 ZEPHYRHILLS, FL. 33541 ZEPHYRHILLS FL 33541-2275 Phone: (813)782-0825 Lic: Phone: 813-782-0825 Work Desc: CONSTRUCT TRIPLEX 1466 SQ FT APPLICATION FEES BUILDING FEE 687.92 ELECTRICAL FEE 134.10 PLUMBING FEE 89.40 MECHANICAL FEE 62.58 SEWER CONNECTION RESIDEW 2,010.00 WATER CONNECTION RESIDENI 641.00 FIRE PLAN REVIEW FEES 76.32 FIRE INSPECTION FEES 12.50 PARK FEES SF 769.56 TRAFFIC IMPACT FEE 99% 1,640.43 TRAFFIC IMPACT FEE 1% 16.57 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 �" C J Ins ection a uired FOOTER 2ND ROUGH PLUMB WHOL, INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC, ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CO CTOR GNATURE PERMIT OFFI EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER 78134s0-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received _ � . Phone Contact for Permitting •^� -ry C� Owner's Name i�G.,Y) C t n- vrlkt' (-1�% �,�C> Owner Phone Number 1.3-- IL�'1- 8�IJ' Owner's Address L�1 ��` 5 �� ! `�I�S �' `�' �`�l Owner Phone Number Fee Simple Titleholder Name Owner Phone Number I Fee Simple Titleholder Address (�(�(� LOT# 3 JOB ADDRESS ^� 22 SUBDIVISION >r!--,� �NOa -aL " �11 )3�o-o©C?f9C`)(� �3 7� PARCEL ID# (OBTAINED FROM PROPERTY TX(NOTICE) WORK PROPOSED NEW CONSTR ADD/ALT 0 SIGN = = DEMOLISH INSTALL a REPAIR PROPOSED USE E� SFR = COMM = OTHER TYPE OF CONSTRUCTION I BLOCK . = FRAME STEEL = DESCRIPTION OF WORK J rr BUILDING SIZE SQ FOOTAGE 1 tri G HEIGHTI =BUILDING $ 9 5- l 0 00 VALUATION'OF TOTAL CONSTRUCTION =ELECTRICAL $ I J AMP SERVICE 0 PROGRESS ENERGY Q W.R.E.C. =PLUMBING $ (�00 =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION ` Y S� =GAS = ROOFING Q SPECIALTY = OTHER a FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES v NO C/4.h- BUILDER' COMPANY VVIC.f1 con'-��'!u�( SIGNATURE REGISTERED YV N FEE CURREN Y/N I / Address License# J ELECTRICIAN COMPANY �tsSLC9 `�f�ri+v SIGNATURE )!!11 REGISTERED Y/ N FEE CURREN Y/N Address `lJ� 5 License# ^ —� �,i PLUMBER `/ - COMPANY- =� 3 5 C\1.���� ✓O , SIGNATURE REGISTERED Y/ N FEE CURREN N Address License# -- MECHANICAL COMPANY Su I/\V\4 ���... SIGNATURE REGISTERED Y/ N FEE CURREN Address License# OTHER SIGNATURE,. REGISTERED / N FEE CURREN LY/N Address b 4 1 ,SZ r 4;`15 f L I License# 6C 613 RESIDENTIAL >. Attach-(2):Plot Plans;"(2)sets ofBuilding Plans;(1)set'of Energy Foams;R-O-VII Permit.for new-construction, -Minimum working days-after..submittal=date. Required onsite;Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary..;Facilities•.&;1,..dumpster;Site.Work'Permit for•subdivisions/large projects COMMERCIAL Attach,(2)cornpiete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit forall-new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of,Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of•Commencement is required. (AIC upgrades over$7500) *" Agent(for the contractor)-or Power of Attorney(for'the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) =-" ~°"-.G�s•._.:,._,rt%-•r= Reroofs if shingles Sewers €.. .,ySice~U}grades,..A/C,eu.:.aEences(PIoUSurvey/Footage) Driveways-Not over Counter if,on;public roadways..needs=ROW& 1 , ._.___ .-�.,.-.v,..<...�...K�x��s�rn-.ssssx.xuti��.-n�:aa�-�.�:F}•5°frh'^,:.�'a",_s-:EYo� I NOTICE OF DEED RESTRICTIONS: i he undersigned understands that.this,permit may:be subject to"deed"restrictions" which maybe more.restrictive',tham Count re ulations: �Thefundersi ned assum`es�'res onsibil't °for�com p lf'Ance'With`bh y I Y 9 g P Y P y . . applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the�owner-has;•hired­6a-contractor or contractors to undertake work, they may be required.to be.licensed in accordance with state and local regulations: If:4he contractor is not licensed as required(by law, both the owner and,contractor-hiay be-cited-for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirernents.may=apply for-1he' intended work, they are advised to coritacfthe Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired-- contractor or contractors, he is advised to ;have,the contractors).sign portions of the "contractor Block" of this application for which they will be responsible. If you, as,ithe'owner sign as th'e contractor, that may be an indication that he is not properly licensed and is not entitied'to permitting privileges in Pasco County. TRANSPORTATiON IMPACT/UTILITItS.iMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may.'appiy to the construction of new buildings, charde::of- use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07.and 90-07, as amended. The undersigned also understands, that such fees, as may:be due, will be�identified at-the tirrre cf permitting. It is further understood that Transportation Impact Fees and Resource.-Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the-project does not involve a certificate of occupancy,orr, final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due,they must be paid prior to'permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION r!;•IiEN LAW(Chapter 713, Florida Statutes,as amended): if valuation of work is$2,500.00 or more,..1 certify that 1, the applicant, have been provided with a copy-of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer:Affairs. If thel applicant:is'someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the`owner"prior to commencement. CONTRACTOR'S/OWNER'S AFFiDA'40.T: i certify that all the information in this application is accurate and that all-work will be done in compliance with all applicable laws regulating construction, zoning and-land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that i understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such.agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps,of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks.. - US Environmental Protection Agency-Asbestos abatement. Federal Aviation Authority-Runways. I understand that the foilowing restrictions apply to the use of fill: Use of fill is not allowed in Flood Zone W"unless expressly permitted. If the fill material is to bel used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will I be submitted at time of permitting which is prepared by a professional engineer licensed.by the State of Florida. if the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that flll1will be used only to fill the area within the stem wail. If fill material is to .be used in any area, 1 certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect-adjacent properties, the owner may be cited for violating, the conditions of the building permit,issued.under the'attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. if I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other-installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical I codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in'plans, construction or violations of any codes. Every permit issuedishall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety(90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned. i WARNING TO OWNER: YOUR FAILURE TO RECORD A, NOTICE OF COMMENCEMENT i111A�RESULT Ulm YOUR PAYiNG TWICE FOR IMPROVEMENTS TO YOUR:.PROPERTY. -IF'YOU4NTEND•TO OBTAiN F11N 1 NCIRIG, CONSULT WITH YOUR LENDER®R AN ATTORNEY BEFORE:RECORDING Y> "NOTICE OF'COiU MENCEMENT. FLORIDA JURAT(F.S.117.03) owNl=R OR AoI~caT - - _ �oivrRAcroR _ Sub on ed and sworn r afri d)bef a me this Subs;rib d savor to(or rrme )b for this _ S 1 by "� ,y Who is/are persona known to me has/halve produced Who is/are perso i�owa-t a or has/have l5roduc6d as identification. as identification. 1 .�— Notary Public f Notary Public Commission No. Commission No, i „uu„ ANN YNON TERRY Name of Notary e,.' ;�j s grPublic-state a o r a Name of Notary eklj or st N TERRY * = Commission#FF 958064 ;rM",zNotary Public-State 041orlda'• • Commission#FF 958064 MV Comm:Expires Apr 4.2020 , MyComm.Expires Apr 4,2020through National Netarv • r,,. ,,. •• 4•••' Bonded through Nallanat Notary Assn.. / r rl RASDO C, TY, FLORIDA Permit No. t j `orb Date Permitted Builder Name/Owner Name 41 MIZA_- �o'ftAll,Control#' County Parcei No. 2-z( y�,(i3D1� -hill i)b� 3 SubDiv: r, 7 � Address/Location ClassificationlType of Use le'la& - 4 �a TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: 1100- Exempt ❑Yes [] No j How w Determined Impact Fee Amount $. Zone No. TAZ: SCHOOL IMPACT FEE Account (056) Single-Family Detached House Amount $ (057) Mobile Home (058) Other Residential 123) Collection Fee Exempt ( Yes ❑ No How Determined PARKS AND RECREATION FEE Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation Total Zone TOTAL AMOUNT $ 7 �� Exempt ❑Yes ❑ No How Determined LIBRARY FEE Land Account Land Credit Land Total Facility Account Facility Credit Facility Total Exempt ❑ Yes [] No How Determined Total Amounc- 6-7 RESOURCE FEE ERU TOTAL AMOUNT Prepared By Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY i i Acknowledgement below does not Imply acceptance of concurrence,but simply receipt of a copy of this form,placing the building permit owner on notice of this assessment and the conditions of payment for same. y DATE RECEIVED BY RECEIPT NO. DATE BY ' F 6768 BASSWOOD CR-RYMAN CONSTRUCTION-1466 sq ft Uolumn Es SQ.FEET PRICE MAIN OR LIVING: 1,466 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: w $ - VALUATION $ 135,450.00 contract price FEE SHEET $ 596.00 ADDRESS 40.00 DRIVEWAY 1 $ 40.001 BUILDING: $ 687.92 ELECTRICAL: $ 134.10' PLUMBING: $ 89.40 MECHANICAL: $ 62.58' SUB-TOTAL $ 974.00 TOTAL I$ 974.00 SEWER: $ 2,010.00 WATER: $ 641.00 IRRIGATION: $ - TOTAL]$ 2,651.00 t MASTER METR L IRRIGATION METER I$ - FIRE DEPARTMENT FEES PLANS TOTAL: $ 76.32 INSPECTION TOT $ 12.60 PERMIT TOTAL r PLANS $ 88.82 PUBLIC SAFETY IMPACT FEES POLICEL$ 273.00 FIRE $ 254.00 o, 5%1 $ 26.35 TOTAL:j $ 553,36 SUB-TOTAL $ 4,267.17. PARK IMPACT FEES IF 769.56 SIF'S:ICJ 10 - 1.0%1$ TOTAL:j$ 7- Y-14� TIFS:j $ 1,657.00 25%due at permit pick up$414,25 75%$1,242.75 due before pre-mete rl l%j $ 16.67, TOTAL: $ 6,693.73 02-26-21-0300-00000-0330 1 Pasco County Property Appraiser Page 1 of 1 Data Current as Of: Weekly Archive - Saturday, October 28, 2017 Parcel ID 02-26-21-0300-00000-0330 (Card: 001 of 001) Classification 00 - Vacant Residential Mailing Address Property Value RYMAN CONSTRUCTION INC Ag Land $0 36413 STATE ROAD 54 Land $15,449 ZEPHYRHILLS FL 33541-2275 Building $0 Physical Address Extra Features $0 6768 BASSWOOD CIR ZEPHYRHILLS, FL 33542 Just Value $15,449 Legal Description (First 4 Lines) Assessed (Non-School Amendment 1) $15,449 See Plat for this Subdivision Taxable Value $15,449 DRIFTWOOD PHASE V PB 62 PG 071 LOT 33 OR 6452 PG 1430 Jurisdiction City of Zephyrhills Land Detail (Card: 001 of 001) _ Line Use De-s-c-riip-t-ioo-n�Zooning Units _ Type _Price Condition Value — 1 0100 SFR I MPUD 1,640.001 SF i_$8.75 1.00 $14,350 2 { 0100 SFR MPUD 478.00 SF $2.30 1.00 $1,099 Additional Land Information FEMA AcresFO.05 Tax Area 30ZH Code I X Residential Code DRIFLPI Building Information - Use 00 - Unimproved (Card: 001 of 001) Unimproved Parcel 00 - Unimproved Extra Features (Card: 001 of 001) _ Line Description 1Year—._ ___ nits Value No Extra Features Sales History Previous Owner: N/A l Month/YearBook/Page Tye Code Condition Amount 06/2005�6452 / 1430 _ Warranty Deed Vacant $0 _ 07/1981 1114i / 0112 Warranty Deed Vacant ' $0 01/1981 11105 / 0358 I Executor's Deed (Personal Vacant $0 I Representative's) I http://search.pascopa.com/parcel.aspx?parcel=2126020300000000330 11/2/2017 Single .Family Dwelling Plan Review Comments 1. F.F.E. shall.be a minimum of 8"above the road elevation.-and an engineered site plan. . 2. Lots shall be graded to comply with R401:3 of the F.B.C. 3. ;Compaction test required if 24' or more of fill dirt.is brought in at anyone place 4. .Tie in survey required before pouring concrete.. .. 5. Driveways require a R.O.W. use permit. ;All.4 sides of driveway thru the sidewalk shall have expansion material. 6. All setbacks shall be met. T . ,All property markers shall be uncovered'and in at time of first inspection: 8. All A.D.A. requirements shall be met... 9. No electric,=plumbing, mechanical,.or framing shall be covered without an inspection and. approval first. . 10:.A1i Garages shall comply with section R302,6 of the F.B.C.'(Fire Separation): . 11. Appliances shall not be installed in.a location where subject to mechanical damage unless protected byapproved barriers. M303.4 of the F.B.0 12. Water heaters shall comply with section P607.3'of the F.B.C. 13. Foundation supports for A/C units shall.be raised at least 3" above finished grade. M1308.1 14. Return air in all bedrooms. F.B.C. M16.20.4 15. Smoke detectors are to be installed in accordance with R313.1 .of the F.B.C. 16,All glazing requirements are to be in accordance with R308.4 of the P.B.C. 17. All means of egress are to.be in accordance with R311.of the F.B.C. i s. `.`Green.gypsum board" shall not be used as a Backer in showers or tubs. R702:4:2.F:B.C: 19. Combination-type AFCI breakers are required at all.locations requiring an AFCI type breaker.. 20. Carbon:monoxide alarms will be required in new construction that uses fossil-burning.heating or appliances or an attached garage. They.shall be installed in accordance with the T.B.C. 21. All pliinibing, mechanical, and electrical,shall be separate from unit to unit. This includes all underground plumbing and electric. 22. All 2008 N.E.C. Codes will be enforced. 23. Tamper- Resistant Receptacles in accordance with 406.11..of the 20.08 N.E.0 22.. In accordance with the Land Development Code, lots shall be sodded before final at least 10 feet around the structure: F.F.E.-Finished Floor Elevation F.B.C- Florida Building Code 5 h Edition R.O.W.-Right of Way A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code (2008)- Unit 33 Column Es SO. FEET PRICE UNDER ROOF: 1,466 $ 112.65 OTHER: - $ - VALUATION $ 165,144.90 FEE SHEET $ 686.00 ADDRESS $ 40.00 DRIVEWAY $ 40.00 BUILDING: $ 779.72 ELECTRICAL: $ 154.35 PLUMBING: $ 102.90 MECHANICAL: $ 72.03 SUB-TOTAL $ 1,109.00 TOTAL $ 1,109.00 SEWER: $ 2,010.00 WATER: $ 641.00 IRRIGATION: $ - TOTAL: $ 2,651.00 WATER METER: IRRIGATION METER FIRE DEPARTMENT FEES PLANS TOTAL: INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 4,313.35 PARK IMPACT FEES $ 769.56 SIF'S: 100.0% $ - 1.0% $ - TOTAL: $ - T I F'S: $ 3,480.00 99% $ 3,445.20 1% $ 34.80 TOTAL: $ 8,562.91 2017146961 Permit No. Parcel ID N0 o a-a 6 a I-C)�jO t7 ODOA�'o jai 0 NOTICE OF COMMENCEMENT State of 7r-\,0%X V)AC County of ,P PeS C-0 THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and In accordance with Chapter 713.Florida Statutes, the following information is provided in this Notice of Commencement 1. Description of Property: Parcel Identification No. n a -a 6-a 1—0'A00- 0 0 000—033 0 °NQ r+ s Street Address: 2. General Description of Improvement !1/'r w d.1J S-t-4LL+.CTT Lq J N 3 m 3. Owner(Information or Lessee information if the Lessee contracted for the improvement: o`^{tMGL•� Cpyt-S'YrwGh��1 �T,r/�G- dome �p • e " �41� �alce�� 4P.r0rryyiki 115 'fir am Address '� City V State Interest in Property: Its Name of Fee Simple Titleholder. x (If different from Owner listed above) Address !� /� L �}. City State JkSIK 4. Contractor. Name 36Y� citya r011.'ti�•(t5 State Address 13 13-"?g JL-013; m n Contractors Telephone No.: re F per 5. Surety: y z rD 32 m Name CoN 0 B z Address City Stale "rm Amount of Band: $ Telephone No.: N? 6. Lender: Name b n 3 a Address City State Lender's Telephone No.: a x 7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)(7),.Florida Statutes: ;�r•+no v' Name N c Y U Address City 'm V W State W LL. W W Telephone Number of Designated Person: Ur O= J U J > 8. In addition to himself,the owner designates of— Co z U U) J O N to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statutes. 0 W Telephone Number of Person or Entity Designated by Owner. O � =Z J D_ 9. 6piration date of Notice of Commencement(the expiration date may not be before the completion of construction and final payment to the 0 I_ p Q O contractor,but will be one year from the date of recording unless a different date is specified): Ll.l LL_ W U WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE AND CAN = r OLL RESULTtINIDYOUR PAYINGPER PAYMENTS UNDER TWICE FOR MPROVEMENTSPTORYOURPART ROPERTY.TION A NOTICE OFORIDA COMMENCE STATUTES. MUST BE Q t-- i3' W O Y RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT U _0 V z W WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. J I- 1- J d Under penalty of perjury,I declare that I have read the foregoing notice of commencement and that the facts staled therein are true to the best .0 } U m 0 U_ U of my knowledge and belief. U- W � z O J_ LLI STATE OF FLORIDA 0 � W LL' = Q Z COUNTY OF PASCO J ul 0 0 } 0 Sign a of L ea,or Owner's Lessee's Autho ed u" U U W Office . ctor/Partnerl a at O 0 0 0 LILI W Cf) < _J l J Signatory's Title/Office I/ Q Z) The foregoing instrument was acknowled ed efore me this 15 da/y of�—,2011 by Wa,/ L ellm" _ W z Q tb 9 9 as g I AL SI GCfil (h P ty, 9•, Y ) f/� F- I- O n. e of authori e. officer,trustee,attome in fact for rvMAA A S fN �4C. (name of pa y n behalfpf w4om in nt was executed). Personally Known OR Produced Identification❑ Notary Signature ,,771/ Type of Identification Produced Name(Print) ANNA MAHIE LYNCH TE P�• 1 Notary Public-Slate of Flu ° Commission N FF 9580f i ¢� m e m s �J e1,� My Comm.Expires Apt 4.202v Ni110Rai Notary Assr Bondedtllrouglr _ .. -� '•' r. � �- .� wpdata/bcs/noticecommencement_pc053048 _ lu z. v y y Ix y T1 '~ +r,- .. IF' -r ^ �..t7' ' _ - 'r =- WR y y yr: •' V&' - �I �:,,;>: s,'wv. �` �tfi• [ 7~ ? ° Ali: °ru ;`a f �. ...c•: s- �.:>.�,: - ,:w ;.t.�",•• - 'v. - '�^��, .� '�-' -°� .'fit--^�j_ _ .�, ;*�:•rr' ?;a,: ;--r,.• ��".�_a,aj;�; "� �. .' �( -'Q'' > - O.. '�``;.a =3i�- _s r _ •d `-�'.' O "s�::.w�."-,�'?,a;:s;.- :;m,:.,,�:r:r C. .. .. s _f-- 'O'�r.�.,, �;ict�•_�c' :Gts,r :ate:• ,�" =-=*^:= OY �-'_� - - �Ow�fi .nn:<: -•.ter "' ..�ti ,}ye ,iv. go-. - t''.. 1�, .:;,�}e•Y' =:s{:i"; i �c=inK :.1. ,v�, ':a:-.�.„,'v �.45,r y.' a• t, "- s�_`-3•s �t P.•r-.c' �':,,`h',';'<<E .•�:_ - Iry" ca:a:=>• `a 4i ,'I"E .•--�'". :" = _ `.'s .,,Y - 3} .✓FC.3i`',--;1:�.. `.�5':.` �'; _r:°.ix ,:5.>z„t,': - _ ��. ��'a, ._.� �',,,�.��,•s�•+,:.� _ ti - -� �-,._.:•'a,,,"- .y.,; ..:�., ,<Y':`�-.'n _.:.; -- I _s� _ _ sx� "�s '"�,�^. _ �n .••Kn: ';.'.m -f��,y ems,.. _Rrn - .•�' ;iu• - z1t - , .tad _ c •�`-a � -x ;,'�;;�.".,� t t 2 .50 5.5 5 2 35.5 35.50• � � � �-- •�; ..37. ;�,��2• .11�" ;� �2,5�5�' �;2 �5Q-„ -:� �-� r25,-.5 r = = = 35:5'x '�'--�z.�. :•�3�..91__„'i�,-�_� :�,."�...... 600.23 `;�- - t" �, :�� ->,w.. b:f:s._..�,,,� �'" -r€.w � ��,� ��• ��_.�"` :�r��,v.,,;�>�._�;:�>_,.: `4�.$4 %R "n: s _ as - s _ - .., y�'a:, _. "• • _ - �'"-a�. ';t•' _ IRS � 0 �„:.-:.ram•. arm - 3;y"'";t �`�''3t`.M1:�.:r i.� �h r'Skh,„•`<:�.� �tQ>t -c..2�`S' "-- i�t .`-a, �`EtT,��-..a N`'��y�:-�'4� � _ -rP - E _ _ - RACT Q Q _.� `3>s�=1��'..i->. �.zy,,;•zTt"z�,zr w`��tn� ,�,.i: ,�-3,� -•S�; -r�,�r '•.y. --- � �.fi' - .`r. .at.+ i. r r'Y== s-.v„='•__',,,, otSxrr'-` "S 4 .;:�1. .. �Y�•.�µ - - �- `3 ��:` �!• n-' ,. e ..�^ram -: .�.1 ^•'v�v�"•.a �.r _ .r�� 'm - �-:� ;4�""�.,— _ - a _ -r - - .�` ,. _ .�•�?,,,: "� .�-> .��•"` •+�:_ ��:�x,•_- - - - - - -� _ -- — �- s- .t. -r: ;un.'S% �,,BC• ,m;. > :.t�:"''� ...F4s:;,- i ^'?[�'"<. _ �5 - � _�?� � �1 � �.r..,x -� _ �RETENTIQN rh����-:S �� •5"3-4.; '-#.•• +'M�`t� _ _ err, '�e c Rr,. q� ,2 �.�"•x-.. ryy�,. _ .!E�Yk.. .�. '•"�_ ;x ^s'�~ rr�y�V- .'£,•= -°`~ _ _ e "...flu' p Q � a_�� .: � t �� 'r,:' .�• `� :. '.. r �- ;<.�-> _� ,:�'. - uf� -.� �� y o.��''r'E� �. _;. �� LANDSCAPING ao z��":�i .'•..� ,x„y.,c�� -�i9p.�• a+:-rr-ar�f`- 'r`.' ,r - _ - _ �'. ;tr'.�.:( :' s 's^ i i.v. - �+ f G� �GRES.S�=i�DiA; =.�' Tf1=iTY; E ;�:r_�z_ .� _�. ��''- .-��- �.: f NJ\G�E�_l E:T +�'_ .. :::���.r.���� � iw.,...u._.,���s_..�..::�.:•�- -..;a.'� ��:.• �`�- - � . . L " Ht t 2 .89' 2 E 3 3.90 -�.��_"-�t_ '�� - '��,�,, �;�a 50.'!1 6 3.00' 1.88' 33.00 2 .50' :' 4= :.':'~ 50' "' 3.03' N 9°53'32"E_�00 o r '':�- O O O 2 O rfin'v." '�." rn 0 0 CDrn ,: c3 r N 89°53'32°E 77.00'I i Oo ( Oo y O O 4 :'•y�u� '4 ''T "' 3� M. "' 36 "' 35 "' 3' 33 m 32 m 31 o N �ui'-; `-' N [ 4 �2 y y OR in ' :... O O y y 'iy 3 s Sal -1 -I m t m n O b o o ',To 0 CD 89°53'32"E 77.09 } S �8o 1 d i 6 f tiKl E a t N (3'1 23 3 0' 33.00' i ca 00' 27.50' 27350'tww 27.50' 27.50' 33.03' 3 '' 3 € E O a , n E"�.`>,, ;: R' 176,03' O , ) CD -:. co N 89°5332"E 77.00'{ N895332 `; a, r " .� " .: i w•ytiy ; may, i iSEMENT s a;,y '';'. O TRACT 'B° POSSIBLE REAR ::a'� '� � � O =rx w W 0 RETENTION PORCH TYP :``st fit;:: 0o n `' ! ' �� cn N ce ! •�:'•="r'"t;;�<'u. ;ram' F,rt s i .-..,.. m O 383.90 N 89 53 32 E 69.93 . 89°46'30"W 550.21'(F) >; . ,; __ _ o s 89°48�52°W 550.26'(a) DRAINAGE EASEMENT 20.00 Drainage and Rafert6an Area Per Plat Efdsting Handing a O ( i Finished Floor r' I `m " O t ,::e. `ti'• 2 Movaton=o2,7o II LO �+�} "'� Cy '• w m to 25 ` F Lot 138 m Is Lot 132 A Ebsffn98otlding = Y• •',''oi I II Fci>Sshed Pbor :'�`# `:;_- ! N Elevation $9°5332°E 70.18'; I •�•,...p A ! =g1.39 •�F ,•:';' :;` c Lll i c t'iJS:'`�'CINt:�'�'n�•ai':°- '�`�i cn U) �`�4 (m� '� ham• \✓ Is 9 s `I COW N 89°53'32 E 70.3 i � ( O FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Ryman 6 Plex Builder Name: Street: Permit Office: Pasco City,State,Zip: Dade City,FL, Permit Number: Owner: Ryman 6 Plex Jurisdiction: Design Location: FL,Tampa COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated, and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed'boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 9/7/2017 7:58 AM EnergyGauge@ USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 . . ' F0RMR4U5-2O14 FloridaDepartmentnfB ' d Professional R |af Residential Whole Building Performance and Prescriptive Methods ADDRESS: Permit Number: Dade City,FL, MANDATORY REQUIREMENTS See individual code sections for full details. O ^o1.0 Energy Performance Level(EpL)display card(M*ndam,y). The building official shall require that an energy performance level(sPL) display card ue completed and uamfieduy the builder mbo accurate and correct before final a |u,thebviNinOmrvccuvanq/.rmhua|mx [Section 553.9085,Florida Statues]requires the EPL display card to be included as an addendum to each sales contract for both prenoldand nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components installed ma dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted m demonstrate compliance for the building.A copy of the srL display card can be found inAppendix C. [] n40e.4 Air leakage<Mongatory>. The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections n^uo/through nwux4.4 . ��' O R*oo.«.1ouim|n8mhemoa/wmve!vne The hundino thermal envelope shall comply mNo8em �.—F saa|inmmothodabaxwoenuias|nd|ormamhmxsxvoaoow for differential expansion and contraction. ^ m40c4.1'1 Installation.The components uf the building thermal envelope aa listed in Table n«me.41.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table 402.4.1.1,as applicable to the method of construction. Where required by the code official,an approved third party shall inspect all components and verify compliance. ^ n402.*.1.2Tosung. The building or dwelling unit shall ba tested and verified ua having un air leakage ratev/notmmoedinDuair changes per hour in Climate Zones 1 and 2,and 3 air changes per hour in Climate Zones 3 through u.Testing shall m,conducted with u blower door ata pressure ofo.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.x written report vf the results of the test shall ue signed by the party conducting the test and provided m the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall uo closed,but not sealed,beyond the intended weatherstripping mr other infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; o.Interior doors,if installed u'the time nfthe test,shall uaopen; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if Installed at the time of the test.shall be fully open. O R402.4.2 Fireplaces.New wood-burning fireplaces shall have tight-fitting flue dampers and outdoor combustion air. O R402.4.3 Fenestration air leakageVVindows,skylights and sliding glass doors shall have an air infiltration rate of no more than O.acfm per square foot tuUuxnu>.and swinging doors no more than V.00mo per square foot(2.oupxnu).when tested according mmpRo*000, xxmmvNDw^/CSA l0l/L&2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. u R4n2AA Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed m limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall ba IC-rated and labeled as having mn air leak waurate not more than 2.0 cim(0.944 L/s)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential.All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. O R403.1.1 Thermostat provision(Mandatory).At least one thermostat shall be provided for each separate heating and cooling system. O R403.1.3 Heat pump supplementary heat(Mandatory).Heat pumps having supplementary electric-resistance heatshall have controls that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. O Soehne(Mandatory)NJI ducts,air handlers,and filter boxes and building cavities that form the primary air containmentpassageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed In accordance with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post-construction or rough-in testing below. Duct tightness shall be verified by testing m Section mmof the nESNET Standards by either an energy rater certified in accordance with Section u53.an.Florida Statutes,mas authorized by Florida Statutes,toba"substantially leak free"by either of the following: 1. Post-construction test:Total leakage shall ba less than nr equal m4 cln(113Umin)per 1ou square feet(o.2Sm2)uf conditioned floor area when tested ute pressure differential o,n1 inches vuu.(25 Pa)across the entire system,including the manufacturer's air handler enclosure.All register boots shall uu taped m otherwise sealed during the test. } e. Rough-in test:Total leakage shall he less than o,equal to 4 cfm(113 L/min)per 100 square feet(9.29 m2)of conditioned floor area when tested ata pressure differential ufo1 inches w.o.(25Pa)across the system,including the manufacturers air handler enclosure.All registers shall be taped v,otherwise sealed during the test.|f the air handler is not installed at the time of the test,total leakage shall be less than or equal to 3 cfm (uuumN)per 1on square feet(9.2om2)m conditioned floor area. Exceptions: 1. The total leakage test is not required for ducts and air handlers located entirely within the building envelope. z. Duct testing m not mandatory for buildings complying uy Section n*oovf this code. FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) 0 R403.2.3 Building Cavities(Mandatory). Building framing cavities shall not be:us'ed as ducts or plenums. 11 R403.3 Mechanical system piping Insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41*C) or below 55°F(13°C)shall be insulated to a minimum of R-3., R403.3.1 Protection of piping insulation. 11 R403.4.1 Circulating hot water systems(Mandatory). Circulating hot water systems shall be provided with an automatic or readily accessible manual switch that can turn off the hot-water circulating pump when the system Is not in use. 0 R403.4.3 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers-s—ha7f­Fa—ve heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3 1/2 inches(89 mm)in the hot water distribution line and cold water line located as close as possible to the storage tank. 0 R403.4.4 Water heater efficiencies(Mandatory). 0 R403.4.4.1 Storage water heater temperature controls • R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature setting range shall be from 1 00'F to 140°F(38'C to 60'C). • R403.4.4.1.2 Shutdown. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s) of combustion types of service water heating systems to be turned off. O R403.4.4.2 Water heating equipment Water heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 In Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1. R403.4.4.2.1 Solar water heating systems.Solar systems for domestic hot water production are rated by the annual solar energy factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems.Solar collectors'shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors, and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol,Collectors in installed solar water heating systems should meet the following criteria: 1. Be installed with a tilt a'ngle between 10 degrees and 40 degrees of the horizontal;and 2. Be installed at an orientation within 45 degrees of true south. ❑ R403.5 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code,Residential or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. 11 R403.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment. 0 R403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section RS02.1.This code does not allow designer safety factors,provisions for future expansion or other factors which affect equipment sizing.System sizing calculations shall not include loads created by local Intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. • R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load,but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.6,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load. 9/7/2017 7:51 AM EnergyGauge@)USA-FlaRes2014 -Section R405.4.1 Com Page 2 of 3 FORM R405-2014 MANDATORY REQUIREMENTS - (continued) O R403.6.1.1 Cooling equipment capacity.(continued) The published value for AHRi total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacture's expanded performance data shall be used to select cooling-only equipment.This selection shall be,used to select cooling-only equipment.This selection shall be based on the outdoor design dry bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower cfm provided by the expanded performance data, the design value for entering wet bulb temperature and the design value for entering dry bulb temperature. Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space. Exceptions: 1. Attached single-and multi-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida-registered engineer,in attached single-.and multi-family units,the capacity of equipmeot-may be sized in accordance with good design practice. O R403.6.1.2 Heating equipment capacity R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section R403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load. R403.6.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.6.1. ` R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated In accordance with Section R403.6.1. 0 R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base toad periods is utilized. ❑ R403.7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the Commercial Provisions in lieu of Section R403, ❑ R403.8 Snow melt system controls(Mandatory). Snow and ice-melting systems,supplied through energy service to the building,shall include automatic controls capable of shutting off the system when the pavement temperature is above 55•F,and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40•F. ❑ R403.9 Swimming pools,Inground spas and portable spas(Mandatory). The energy requirements for residential pools and inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSIIAPSP-15.The energy requirements for portable spas shall be in accordance with ANSItAPSP-14. 0 R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on-off switch that is mounted outside the heater to allow shutting off the heater without adjusting the thermostat setting. R403.9.1.1 Gas and oil-fired pool and spa heaters. All gas-and oil-fired pool and space heaters shall have a minimum thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013 when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot tights. R403.9,1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. 0 R403.9.2 Time switches. Time switches or other control method that can automatically turn off and on heaters and pumps according to a preset schedule shall be installed on all heaters and pumps.Heaters,pumps and motors that have built in timers shall be deemed in compliance with this equipment. Exceptions: • 1. Where public health standards require 24-hour pump operations. 2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation. 0 R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shalt be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Outdoor pools deriving over 70 percent of the energy for heating from site-recovered energy,such as a heat pump or solar energy source computed over an operating season. ❑ RR404.1 Lighting equipment(Mandatory). A minimum of 75 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps. Exception: Low-voltage lighting shall not be required to utilize high-efficacy lamps. 0 R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights ❑ R405.2 Performance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R-6. 0 R405.2.1 Performance ONLY. Ceilings shall have minimum insulation of R-19.Where single assemby of the exposed deck and beam type or concrete deck roofs do not have sufftcent space,R-10 is allowed, 9/7/2017 7:51 AM EnergyGauge@ USA-FlaRes2014 -Section R405.4.1 Com Page 3 of 3 FORM R405-2014 ENERGY PERFORMANCE LEVEL (lEPL) DISPLAY CARD ESTIMATED'ENERGY PERFORMANCE INDEX* = 98 The lower the EnergyPerformance Index, the more efficient the home. Dade City, FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area a.Concrete Block-Int Insul,Exterior R=5.0 3114.00 ft2ingle-family-or-multiple-family—MultL-family—�--.—.--b.-Frame 3. Number of units,if multiple family I c.NIA R= ft2 4. Number of Bedrooms 12 d.N/A R= ft2 iO.Ceiling Types Insulation Area 5. Is this a worst case? No a.Under Attic(Vented) R=30.0 6576.00 f? 6. Conditioned floor area(112) 6576 b.N/A R= ft2 7. Windows** Description Area c.N/A R=11.Ducts R ft-' ftz a. U-Factor: Dbl,U=0.30 522.00 ft2 a.Sup:Attic,Ret:Attic,AH:Garage 6 200 SHGC: SHGC=0.26 b. U-Factor: N/A ft2 SHGC: 12.Cooling systems kBtu/hr Efficiency c. U-Factor N/A ft2 a.Central Unit 106.2 SEER:14.00 SHGC: d. U-Factor. NIA ft2 SHGC: 13.Heating systems kBtu/hr Efficiency Area Weighted Average Overhang Depth: 1.000 ft. a.Electric Strip Heat 106.2 COP:1.00 Area Weighted Average SHGC: 0.260 8. Floor Types Insulation Area 14.Hot water systems Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 6576.00 ft2 a.Electric EF:0.95 b.NIA R= ft2 b. Conservation features c.N/A R= ft2 None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building f 14 1 ESr4 Construction through the above energy saving features which will be installed(or exceeded) 0 in this home before final inspection. Otherwise,a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Date: ...... Address of New Home: City/FL Zip: )D WET *Note: This is not a Building Energy Rating. If your Index is below 70,your home may qualify for energy efficient mortgage(EEM)incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation,.contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 9/712017 7:50 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Ryman 6 Plex Builder Name: Street: Permit Office: Pasco City,State,Zip: Dade City,FL, Permit Number: Owner: Ryman 6 Plex Jurisdiction: Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2 1. New construction or existing New(From Plans) 9. Wall Types(4626.0 sqft.) Insulation Area -2.-Single-family-or-multiple-family-----------Multi=family-- -a.Concrete Block-Int Insul,Exterior R=5.0 3114.00 ft' Y-Fta-m-e--Wo-0-d-,Adjacent-------R=1,1- .0--1-512.00t2- 3. Number of units,if multiple family I c.N/A R= ft2 4. Number of Bedrooms 12 d.N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types(6576.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 6576.00 ft2 6. Conditioned floor area above grade(ft2) 6576 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(522.0 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Garage 6 200 a. U-Factor. Dbl,U=0.30 522.00 ft2 SHGC: SHGC=0.26 b. U-Factor. N/A ft2 12.Cooling systems kBtu/hr Efficiency SHGC: a.Central Unit 106.2 SEER:14.00 c. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor. N/A ft2 a.Electric Strip Heat 106.2 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 1.000 ft. Area Weighted Average SHGC: 0.260 14.Hot water systems a.Electric Cap:40 gallons 8. Floor Types (6576.0 sqft.) Insulation Area EF:0.95 1 0 a.Slab-On-Grade Edge Insulation R=0.0 6576.00 ft2 b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 16.Credits Pstat Glass/Floor Area: 0.079Total Proposed Modified Loads: 166.75 Total Baseline Loads: 170.26 PASS I hereby certify that the plao add pecfications covered by Review of the plans and this calculation are in c6m 1 -ph3hce�,�th ihe Florida Energy specifications covered by this 0 Ap Off,Code. calculation indicates compliance With the Florida Energy Code. PREPARED BY: Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes, with the Florida Energy Code. Cps wt IT OWNER/AGENT: BUILDIN =OF IC DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as .certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report In accordance with R402A.1.2. - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house. 9/7/2017 7:49 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1of4 . . . � � 91712017r:4omw Enemvoaug:g USA'RaRauuo1+Section 1CnmpoanoGoftvara Page uvf4 FORM R405-2014 WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below - V# Ornt----To.-WaII-Type -R--Value-F-t-In-F-t-In-Area-R--Valup Fraction-Absor-Grade%- I N Exterior Concrete Block-Int Insul Main 6 162 0 9 0 1458.0 ftz 0 0 0.8 0 2 E Exterior Concrete Block-Int Insul Main 5 47 0 9 0 423.0 ft2 0 0 0.8 0 3 S Exterior Concrete Block-Int Insul Main 5 90 0 9 0 810.0 ft2 0 0 0.8 0 4 W Exterior Concrete Block-Int Insul Main 5 47 0 9 0 423.0 ft2 0 0 0.8 0 5 Garage Frame-Wood Main 11 168 0 9 0 1612.0 ft2 0 0.25 0.8 0 DOORS V # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In S Wood Main None .39 18 7 126ft2 2 Wood Main None .39 17 6 7 122.5 ft2 WINDOWS Orientation shown is the entered,Proposed orientation. Wall Overhang Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening I n I Metal Low-E Double Yes 0.3 0.26 120.0 It' I ft0in I ft0in Drapes/blinds None 2 n I Metal Low-E Double Yes 0.3 0.26 252.0 ft2 1 ft0in 1 ft0in Drapes/blinds None 3 e 2 Metal Low-E Double Yes 0.3 0.26 15.0 ft' I ft 0 in I ft0in Drapes/blinds None 4 s 3 Metal Low-E Double Yes 0.3 0.26 120.0 ft' I ft 0 in I ft 0 in Drapes/blinds None 5 W 4 Metal Low-E Double Yes 0.3 0.26 15.0 ft' I ft 0 in I ft 0 in Drapes/blinds None GARAGE V # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 382.8 ft2 384 ft2 64 ft 8ft 1 INFILTRATION Scope Method SLA CFM 50 ELA Eql-A. ACH ACH 50 1 Wholehouse Proposed ACH(50) .000254 4384 240.68 452.63 .1906 5 HEATING SYSTEM V # System Type Subtype Efficiency Capacity Block Ducts I Electric Strip Heat None COP:1 106.2 kBtu/hr I sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER:14 106.2 kBtu/hr 3186 cfm 0.8 1 sys#1 917/2017 7:49 AM EnergyGauge@ USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 4 FORM R405-2014 HOT WATER SYSTEM V # System Type SubType Location EF Cap Use SetPnt Conservation I Electric None Garage '0.95 40 gal., _.-I 50 gal 120 deg None SOLAR HOT WATER SYSTEM VFSEC Collector Storage Cert * Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS Supply----Retum--- Air EM-2 HVAC* # Location R-Value Area Location Area Leakage Type Handler TOT OUT Q N' RLF Heat Cool I Attic 6 200 ft' Attic 100 ft2 Prop.Leak Free Garage cfm 197.3 cfm 0.03 0.50 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Cooling Jan Feb Apr Y �xl Jun rj Jul rj Augj Sep Oct Nov Dec pr May 9 He Jan Feb H Mar [XI A May Jun Jul AugSe Oct Nov Dec X P Ve Jan Feb Mar Apr may Jun Jul Aug Sep 1XI Oct Hx Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 -8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(VVEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 9/7/20I7 7:49 AM EnergyGauge@ USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 4 Job: Ryman 6 Plex wrightsoft' Project Summary Date; Sep 06,2017 Unit 1 By: DJM -661�ct fiff&64twfi, For: Ryman 6 Plex Dade City,FL Notes: TOMMY]"n.fdr-mation.- Weather: Tampa Intl AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 43 OF Outside db 91 OF Inside db 70 OF Inside db 75 OF Design TD, 27 OF Design TD 16 OF Daily range L Relative humidity 50 % Moisture difference 54 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 10083 Btuh Structure 10451 Btuh Ducts 2317 Btuh Ducts 3367 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 12400 Btuh Use manufacturer's data n Rate/swingmultiplier 0.96 Infiltration Equipmenlsensi le load 13321 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2570 Btuh Ducts 767 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling 11 o (pone) Area(ft) 110 Equipment latent load 3337 Btuh Volume(fis) 9693 9693 Air changes/hour 0.43 0.23 Equipment Total Load(Sen+Lat) 16658 Btuh Equiv.AVF(cfm) 70 37 Req.total capacity at 0.80 SHR 1.4 ton Heating Equipment Summary Cooling Equipment Summary Make Make Carrier Trade 5 KW Trade CARRIER AIR CONDITIONING Model Cond 24ACB318ABN32 AHRI ref Coil FB4CNP01 8L AHRI ref 9859025 Efficiency 100 EFF Efficiency 11.5 EER, 14 SEER Heating input 3.6 kW Sensible cooling 13680 Btuh Heating output 12409 Btuh Latent cooling 3420 Btuh Temperature rise 20 OF Total cooling 17100 Btuh Actual air flow 570 cfm Actual air flow 570 cfm Air flow factor 0.046 cfm/Btuh Air flow factor 0.041 cfm/Btuh Static pressure 0.53 in H2O Static pressure 0.53 in H2O Space thermostat Load sensible heat ratio 0.81 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2017-Sep-07 08:16:11 Right-Suite®Universal 2017 17.0.23 RSU1 1033 Page 1 ...Google DriveXDocumenls1Sonny's1Ryrnan 6 Plex.rup Cale=lvU8 Front Door faces: E r. Project Summary Job: Ryman 6 Plax wrightsio Date: Sep 06,2017 Unit 2 By: DJM For: Ryman 6 Plex Dade City,FL Notes: De sic• Inf6rMa on,-., In. Weather: Tampa Intl AP,FL,US Winter Design Conditions Summer Design Conditions Outside db 43 OF Outside db 91 *F Inside db 70 OF Inside db 75 OF Design TD 27 OF Design TD 16 OF Daily range L Relative humidity 50 % Moisture difference 54 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 6111 Btuh Structure 8327 Btuh Ducts 2331 Btuh Ducts 3390 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 8442 Btuh Use manufacturer's data n Rate/swingmultiplier 0.96 Infiltration Equipment sensible load 11295 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 1846 Btuh Ducts 814 Btuh Central vent(0 cfm) 0 Btuh HeatingCooling (none) Area(ft) log 1090 Equipment latent load 2660 Btuh Volume(ft?) 9693 9693 Air changes/hour 0.20 0.11 Equipment Total Load(Sen+Lat) 13955 Btuh Equiv.AVF(cfm) 33 18 Req.total capacity at 0.70 SHR' 1.3 ton Heating Equipment Summary Cooling Equipment Summary Make Make Carrier Trade 5 KW Trade CARRIER AIR CONDITIONING Model Cond 24ACB318ABN32 AHRI ref Coil FB4CNP018L AHRI ref 9859025 Efficiency 100 EFF Efficiency 11.5 EER, 14 SEER Heating input 2.5 kW Sensible cooling 11970 Btuh Heating output 8448 Btuh Latent cooling 5130 Btuh Temperature rise 13 OF Total cooling 17100 Btuh Actual air flow 570 cfm Actual air flow 570 cfm Air flow factor 0.068 cfm/Btuh Air flow factor 0.049 cfm/Btuh Static pressure 0.53 in H2O Static pressure 0.53 in H2O Space thermostat Load sensible heat ratio 0.81 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Right-Suite®Universal 2017 17.0.23 RSU1 ID33 2017-Sep-07 D8:16:11 ..-Google Dr1ve1Documents%SonnyskRyrnan 6 Plex.rup Cato=MJ8 Front Door'faces: E Page 2 . . Summary Job: m��sm� �� q���~ Project ~~ . , Date: Sep oszm( / ~^��'—~ ���it �� By: muM For: Dade City,FL Notes Dj Weather: Tampa Intl AP, FL, UB Winter Design Conditions Summer Design Conditions Outside db 43 OF Outside db 0 OF Inside UU 0 OF Insidedb 75 OF DaeignTD 27 OF Design TD 18 OF Daily" L Relative humidity 50 9& Moisture difference 64 gr/lb Heating Summary SmwslbW» Cooling Equipment Load Sizing Structure 6111 Btuh Structure 8327 Btuh Ducts 2331 Btuh Ducts 3390 Btuh Central vent(Dohn) O Btuh Central vent(0uhn) 0 Btuh (none) (none) Humidification U Btuh Blower O Btuh P[Pigo O Btuh Equipment load 8442 Btuh Use manufacturer's data n multiplier 0.98 Infiltration Equi»menI sensible load 11285 Btuh Method Simplified Latent Cooling Equipment Load Sizing Constructionque|ity Average Fireplaces � u Structure 1846 Btuh Duds 814 Btuh Central vent(Ochn) 0 Btuh Heatiom ��o�on (none) �a 1U80' 1U8L� Equ|pmentlatent|oad 2880 Btuh Volume 8683 8883 Air changes/hour 0.20 0.11 Equipment Total Load(Sem+Lat) 18855 Btuh Equiv.AVF(ohn) 33 18 Req.total capacity atU.70GHR 1.3 bun Heating Equipment Summary Cooling Equipment Summary Make Make Carrier Trade 50N Trade CARRIER AIR CONDITIONING Model conu 24ACB31BABN32 anmmr Coil FB4CNP018L AHR|mf 9859025 Efficiency 100EFF Efficiency 11.5EER. 14SEER Heating input 2.5 kW , Sensible cooling Btuh �1Q7U �h Heating output 8448 Btuh Latent |�g 5130 Btuh Temperature rise 13 OF Total cooling 171008tuh . Ac�ai air flow 570uhn Actual air flow 570ohn ' Air flow factor 0.008 ohm/Btuh Air flow factor 0.049 uhn/8tuh ' Static pressure 0.53inH20 Static pressure 0.53inH20 Space thermostat Load sensible heat ratio 0.81 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Job: Ryman 6 Plex wrightsoft- Project Summary Date: Sep 06,2017 Unit 4 By: DJM Pr fmati !dJbdf..1hf6r drii For: Ryman 6 Plex Dade City,FL Notes: n f6 rm4ft6n Weather: Tampa Intl AP,FL, US Winter Design Conditions Summer Design Conditions Outside db 43 OF Outside db 91 OF Inside db 70 OF Inside db 75 OF Design TD 27 OF Design TD 16 OF Daily range L Relative humidity 50 % Moisture difference 54 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 6111 Btuh Structure 8327 Btuh Ducts 2331 Btuh Ducts 3390 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 8442 Btuh Use manufacturer's data n Rate/swingmultiplier 0.96 Infiltration Equipmensensi le load 11295 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 1846 Btuh Ducts 814 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh g (none) Area(W) 1090 10 Equipment latent load 2660 Btuh Volume(fl3) 9693 9693 Air changes/hour 0.20 0.11 Equipment Total Load(Sen+Lat) 13955 Btuh Equiv.AVF(cfm) 33 18 Req.total capacity at 0.70 SHR 1.3 ton Heating Equipment Summary Cooling Equipment Summary Make Make Carrier Trade -5KW Trade CARRIER AIR CONDITIONING Model Cond 24ACB318ABN32 AHRI ref Coll FB4CNP018L AHRI ref 9859025 Efficiency 100 EFF Efficiency 11.5 EER, 14 SEER Heating input 2.5 kW Sensible cooling 11970 Btuh Heating output 8448 Btuh Latent cooling 5130 Btuh Temperature rise 13 OF Total cooling 17100 Btuh Actual air flow 570 cfm Actual air flow 570 cfm Air flow factor 0.068 cfm/Btuh Air flow factor 0.049 cfm/Btuh Static pressure 0.53 in H2O Static pressure 0.53 in H2O Space thermostat Load sensible heat ratio 0.81 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Right-SuiteO universal 201717.0.23 RSU1 1033 2017-Sep-07 08:16:11 Google DrivelDocurnentskSonnyslRyman 6 Plex.rup Cato=MA Front Door faces: E Page 4 Pro t Summary Job: Ryman 6 Plex wrightsoft' j ec Date: Sep 06,2017 Unit 5 By: DJM `P*dWct.,1nf.6r t6i For: Ryman 6 Plex Dade City,FL Notes: ;Desiqh4-1-h`fb-r r­'at id Weather: Tampa Intl AP,FL, US Winter Design Conditions Summer Design Conditions Outside db 43 OF Outside db 91 OF Inside db 70 OF Inside db 75.OF Design TD 27 OF Design TO 16 OF Daily range L Relative humidity 50 % Moisture difference 54 grilb Heating Summary Sensible Cooling Equipment Load Sizing Structure 6111 Btuh Structure 8327 Btuh Ducts 2331 Btuh Ducts 3390 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 8442 Btuh Use manufacturers data n Rate/swingmultiplier 0.96 Infiltration Equipment sensible load 11295 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 1846 Btuh Ducts 814 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling (none) Area(ft) 1090 1090 Equipment latent load 2660 Btuh Volume(fP) 9693 9693 Air changes/hour 0.20 0.11 Equipment Total Load(Sen+Lat) 13955 Btuh Equiv.AVF(cfm) 33 18 Req.total capacity at 0.70 SHR 1.3 ton Heating Equipment Summary Cooling Equipment Summary Make Make Carrier Trade 5 KW Trade CARRIER AIR CONDITIONING Model Cond 24ACB318ABN32 AHRI ref Coil FB4CNP018L AHRI ref 9859025 Efficiency 100 EFF Efficiency 11.5 EER, 14 SEER Heating input 2.5 kW Sensible cooling 11970 Btuh Heating output 8448 Btuh Latent cooling 5130 Btuh Temperature rise 13 OF Total cooling 17100 Btuh Actual air flow 570 cfm Actual air flow 570 cfm Air flow factor 0.068 cfm/Btuh Air flow factor 0.049 cfm/Btuh Static pressure 0.53 in H2O Static pressure 0.53 in H2O Space thermostat Load sensible heat ratio 0.81 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Right-Suite@ Universal 2017 17.0.23 RSU1 1033 2017-sep-07 08:16:11 ,CC1K...Goo9le DrivelDocurnentslSonny'slRyman 6 Plax.rup Calc=MA'Front Door faces: E page 5 Job: Ryman 6 Plex ft wrightso , Project Summary Date: Sep O6,2017 Unit 6 By: DJM Pe6jbdt,M46Miatl6d For: Ryman 6 Plex Dade City,FL Notes: irma ilon,­ Weather: Tampa Intl AP,FL, US Winter Design Conditions Summer Design Conditions Outside db 43 *F Outside db 91 *F Inside db 70 *F Inside db 75 *F Design TD 27 oF Design TD 16 'F Daily range L Relative humidity 50 % Moisture difference 54 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 10083 Btuh Structure 10451 Btuh Ducts 2317 Btuh Ducts 3367 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 12400 Btuh Use manufacturers data n Rate/swing multiplier 0.96 Infiltration Equipment sensible load 13321 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2570 Btuh Ducts 767 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling (none) Area(ft2) 1108 110 Equipment latent load 3337 Btuh Volume(ft?) 9693 9693 Air changes/hour 0.43 0.23 Equipment Total Load(Sen+Lat) 16658 Btuh Equiv.AVF(cfm) 70 37 Req.total capacity at 0.80 SHR 1.4 ton Heating Equipment Summary Cooling Equipment Summary Make Make Carrier Trade 5 KW Trade CARRIER AIR,CONDITIONING Model Cond 24ACB31BABN32 AHRI ref Coil FB4CNP018L AHRI ref 9859025 Efficiency 100 EFF Efficiency 11.5 EER, 14 SEER Heating input 3.6 kW Sensible cooling 13680 Btuh Heating output 12409 Btuh Latent cooling 3420 Btuh Temperature rise 20 *F Total cooling 17100 Btuh Actual air flow 570 cfm Actual air flow 670 cfm Air flow factor 0.046 cfm/Btuh Air flow factor 0.041 cfm/Btuh Static pressure 0.53 in H2O Static pressure 0.53 in H2O Space thermostat Load sensible heat ratio 0.81 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Right-SulteO Universal 201717.0.23 RSU1 1033 2017-Sep-07 08:16:11 44351....Google DrivelDocurnentslSonny'skRyman 6 Ptex.rup Calc=Mis Front Door faces: E Page 6 N 6�111 __ s i y,l s�fF. I �o,1aX1 ��la.l . rl•4'm IIIJ,r'n,4 I P --- - ,� 3 - .:�. . . .. ,,.,r,J.,s .., I, JI,�L, I .r�.LI�4. .., ,.-a 1:,.;5. .. .> „t�•.,.rx.,..,-___:::::::.,, - "— - 7'1 �.G .. u a .:. Iw,I I^4#�... P.,:, I I '4 :.I I.n u . :a ...v j•, ..�..., -- -- F. u� Iq - :i�4F1 tl ,....:..:... ,I..,.•:: '..., ,� I lrl� :7�: S i ,I.�:;,3.i? � I'S�'.` y-iri��� t K�i ,Jhrlw,,.;af!xli, •,rlil .paen .1.:1:.!i.` _i tr< ;i..xfSi_,'a, _ 1a' _ __ _ �r _ pp I� 71,1' ,� ;III•. ;Ills:, .,,rr,.R 2n.�4. 5�7, t;._ �x _ _—_- - I I - -- ��� 'u. .,�II II J,II ,� , II'I,H �. ••;',p:q.' •r•ic?� h ...:.:a --i'r: .�, '•Da'ra�lr I, f.,ll� ;,q� I:I�I,I,.r.,,. :J.� �_ r:?+�,.-:�.:;:. _ i'�1" ".' � .JS . � �il'_l l I; ::'':It1�.�:;..PX,�;,�: ...3`,ra.:.i�•F..�'.�"s.v r•-!xns _ ._P!.,.......:..!�:_ :41fi..r' c I I _ _ I � .'i.}I. ,�3.pr F-.T,..,I. In�lll)I�,I,;,!l,P�I�IPII�'�,��',�,:,}•ic`:4Tad,?' _ -':ar:-aµ. i�n..�,_' '!1v "�y 3 .. .•la'll I).,g;in:IJIr P4 M`?>Y°+`;iraol>e� _- - .. I I F Ni .o• r,w. I��t'IiI11:jI�I111H i1i11�1�11t1' .Si3�i�-:kXuaw�',�.u,�xc.w. w, i���'�' I .._.. ,F, V yr� moo. • I •�I I(1 IMi•'L rpt:'s%�Y,i1•il'it, r„+ -' !:I,;�:'!IIi6i :iF' y� . I' ^I'I�Ilili��9mG'::.' K'fir r i Job M Ryman 6 Plex Scale: 1 :270 Performed by DJM for: Page 1 Ryman s Plex Right-Suite@)Universal 2017 17.0.23 RSU11033 Dade City,FL 2017-Sep-OT 08:17:04 ...cumentslSonny'slRyman 6 Plex.ru • j stem Summary Job: Ryman 6 Plex wrigh Duct S tsoft" Date: Sep 06,2017 Unit ' By: DJM a i --Pr0'je6t-Ihf6rm't'o.n For: Ryman 6 Plex Dade City, FL Heating Cooling External static pressure 0.53 in H2O 0.53 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.53 in H2O 0.53 in H2O Supply/return available pressure 0.336 0.194 in H2O 0.336 0.194 in H2O Lowest friction rate 0.363 in/100ft 0.363 ln/1 00ft Actual air flow 570 cfm 570 cfm Total effective length(TEL) 146 ft p'Oh"i-Bra Design Htg Cig Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FIR (in) (in) Mall Ln(ft) Ln(ft) Trunk Unit 1 Bath 1 c 131 3 5 0.420 4.0 Ox 0 VlFx 10.0 70.0 Unit 1 Bath 2 h 412 19 16 0.451 4.0 ox 0 VlFx 4.5 70.0 Unit 1 Bed 1 c 2264 92 93 0,376 6.0 Ox 0 VlFx 19.4 70.0 Unit 1 Bed 2 h 3580 165 107 0.363 8.0 Ox 0 VlFx 22.5 70.0 Unit 1 Kitchen c 2266 57 93 0.413 6.0 Ox 0 VlFx 11.3 70.0 Unit 1 Living c 3092 117 128 0.410 7.0 Ox 0 VlFx 12.0 70.0 Unit I Living-A c 3092 117 128 0.431 7.0 ox 0 VlFx 8.0 70.0 1 f I I I I I I Ko:ra irc • Grille Htg Cig TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FIR (fpm) (in) (in) Opening(in) Matl Trunk rb3 Ox 0 570 570 53.3 0.363 533 14.0 Ox 0 VlFx rst49 7 7 Trunk Htg Cig Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk rst49 Peak AVF 570 570 0.363 533 14.0 0 X 0 VinIFIx ., 4�- wrjqhtS0ft* Right-SuiteO Universal 201717.0.23 RSUI 1033 2017-Sep-07 08:16:11 gz 14EN Page I Gongle DrivelDocumentskSonny'skRyman 6 Plex.rup Calo=MJ8 Front Door faces: E Job: Ryman 6 Plex + wrightsoft,� Duct System Summary Date- Sep 06,2017 Unit 2 By: DJM 7 r•'dct-In ormay.o.n.. For: Ryman 6 Plex Dade City, FL .......... Heating Cooling External static pressure 0.53 in H2O 0.53 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.53 in H2O 0.53 in H2O Supply/return available pressure 0.390 0.140 in H2O 0.390 0.140 in H2O Lowest friction rate 0.420 ln/1 00ft 0.420 in/1 00ft Actual air flow 570 cfm 570 cfm Total effective length(TEL) 126 ft hich-M-etall h ........... Design Htg Cig Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FIR (in) (in) Mall Ln(ft) Ln(ft) Trunk . I — Unit 2 Bath 1 C 143 5 7 0.487 4.0 Ox 0 VlFx 10.0 70.0 Unit 2 Bath 2 h 462 31 20 0.520 4.0 OX0 VlFx 5.0 70.0 Unit 2 Bed 1 h 2259 153 120 0.436 7.0 Ox 0 VlFx 19.4 70.0 Unit 2 Bed 2 h 2238 151 105 0.420 7.0 ox 0 VlFx 22.8 70.0 Unit 2 Kitchen C 2010 11 98 0.475 6.0 Ox 0 VlFx 12.0 70.0 Unit 2 Living C 2263 110 110 0.475 6.0 Ox 0 VlFx 12.0 70.0 Unit 2 Living-A C 2263 110 110 0.500 6.0 OX0 VlFx 8.1 70.0 u rn i ra ft.; • Grille Htg Cig TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FIR (fpm) (in) (in) Opening(in) Mat[ Trunk rb2 Ox 0 570 570 33.3 0.420 533 14.0 Ox 0 VIFx rst47 A46ri-i"TrUhk'*DetaiI;TabIe—' ,' Trunk Htg Cig Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk rst47 Peak AVF 670 570 0.420 633 14.0 0 x 0 VlnIFIx 2017-Sep-07 08:16:11 # WrjghtS()ft' Right-'Suite®Universal 201717.0.23 RSU11033 Page 2 AM GDogle DrivelDocurnentstSonny's%Ryman 6 Plax.rup Cale=M.18 Front Door faces: E . - ` Job: Rymansnax wrightsoft, ��«� �����k� ����k���� Date: a���umT ^ Unit 3 By: o/M .'/ ProiectAnforma ion . For Ryman 6Phex Dade City, FL Heating Cooling External static pressure 0.53 |nH2O 0.53 in H2O Pressure losses O in H2O 0 in H2O Available static pressure 0.53 in H20 0.63 in H2O Supply/return available pressure 0.338/0.181 |nH20 0330/0.191inH20 Lowest friction rate 0.859 |mM00ft 0.359 in/100ft Actual air flow 570 chn 578 uhn Total effective length(TEU 148 ftDet Design Htg CIg Design Diam HxW Duct Actual Ftg.Eqv Name (Btuh) (CfM) (Cfm) FIR (in) (in) Mail Ln(ft) Ln(fi) Trunk MUM BMACK Grille Htg Clg TEL Design Veloc Diam HxW Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FIR (fpm) (in) (in) Opening(in) Mad Trunk Name Type W17171) (Gfm) FIR Upm) (in) (in) Material Trunk +�� amr�=po v�mx, ,�� .� xm�'��u��o�� mum�u�mum"�"ueonn.�oonsu11mm p�en ��m onog/°onvemoc"maomovony'uRym°"nmex.mv Cale~Mm Front Door faces: s Duct System Summary Job: Ryman 6 Plex wrightso Date: Sep 06,2017 Unit 4 By: DJM —V P-r o N 0 • For: Ryman 6 Plex Dade City, FL Heating Cooling External static pressure 0.53 in H2O 0.53 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.53 in H2O 0.53 in H2O Supply/return available pressure 0.391 0.139 in H2O 0.391 0.139 in H2O Lowest friction rate 0.416 in/I 00ft 0.416 in/100ft Actual air flow 570 cfm 570 cfm Total effective length(TEL) 127 ft P• 'Bran."b:Petail':-T • Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FIR (in) (in) Mall Ln(ft) Ln(ft) Trunk Unit 4 Bath 1 c 143 5 7 0.492 4.0 Ox 0 VlFx 9.5 70.0 Unit 4 Bath 2 h 462 31 20 0.522 4.0 ox 0 VlFx 5.0 70.0 Unit 4 Bed 1 h 2259 153 120 0.433 7.0 Ox 0 VlFx 20.4 70.0 Unit 4 Bed 2 h 2238 151 105 0.416 7.0 Ox 0 VlFx 24.0 70.0 Unit 4 Kitchen c 2010 11 98 0.481 6.0 ox 0 VlFx 11.4 70.0 Unit 4 Living c 2263 110 110 0.508 6.0 Ox 0 VlFx 7.1 70.0 Unit 4 Living-A C 2263 110 1 110 0.485 6.o Ox 0 VlFx 1 10.6 1 70.0 1 1 Grille Htg Cig TEL Design Veioc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FIR (fpm) (in) (in) Opening(in) Mall Trunk rb5 Ox 0 570 570 33.3 0.416 533 14.0 Ox 0 VIFx rst44 • T— it hi TtO LFT Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk rst44 Peak AVF 570 570 0.416 533 14.0 0 x 0 VinIFIx g1l 2017-Sep-07 08:16:11 %.L + Wrl ASOft' Right-S.itee Universal 201717.0.23RSU11033 Page 4 Google DriveftcurnentslSonny'slRyrnan 6 Plex.rup Calc-IVIJB Front Door faces: E ` ^ ^ ' ` xuh nymunnpum ����h���, Duct 00Su��k�ary Date: a�m\�1r ^ � Unit 5 By: mM For: RymonGPkex Dade City,FL Heating Cooling External static pressure 0.53 in H2O 0.53 in H2O Pmasum|oaaes O inH2Q U inH2] Available static pressure 0.53inH20 0.53 in H2O Supply/return available pressure 0.381 /0.138 |nH20 0.391 /0.139inH20 Lowest friction rate 0.416 in/100ft 0.416 in/108ft Actual air flow 570 ohn 570 uhn Total effective length(TEU 127 ft Design Htg Cig Design Diam HxW Duct Actual Ftg.Eqv Name (13tuh) (cfm) (cfm) FIR (in) (in) Matl Ln(ft) Ln(it) Trunk FGrille Htg Cig TEL Design Veloc Diam HxW Stud/Joist Duct Size Name (in) (cfm) (cfm) (ft) FIR (fpm) (in) (in) Opening(in) Mail Trunk Or V Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk / | ! | | / / | | / ' / | . | i ' � / / ||^|� »mr�°ro ��u�� . ~ �� ��� mom�^�^um"��eunn��n���om —',' | ~=--- Page / -e°og/oonveMvcurn.omaonny'uftmanoPls.ruv u°/o~mJ8 Front Door faces: c ! ti C. fCae Duct System Summary Job: Ryman 6 Plex �/1j��(��1 �01� Date: Sep 06,2017 Unit 6 By: DJM •J. c • • For: Ryman 6 Plex Dade City, FL Heating Cooling External static pressure 0.53 in H2O 0.53 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.53 in H2O 0.53 in H2O Supply/return available pressure 0.392/0.138 in H2O 0.392/0.138 in H2O Lowest friction rate 0.415 in/100ft 0.415 in/100ft Actual air flow 570 cfm 570 cfm Total effective length(TEL) 128 ft • • pMCIo Design Htg Cig Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FIR (in) (in) Matl Ln(ft) Ln(ft) Trunk Unit 6 Bath 1 c 134 3 6 0.489 4.0 Ox 0 VIFX 10.0 70.0 unit 6 Bath 2 h 412 19 16 0.522 4.0 Ox 0 VIFx 5.0 70.0 unit 6 Bed 1 c 2319 92 96 0.433 6.0 Ox 0 VIFx 20.4 70.0 Unit 6 Bed 2 h 3580 165 110 0.415 8.0 Ox 0 VIFX 24.4 70.0 unit 6 Kitchen c 2321 57 96 0.477 6.0 Ox 0 VIFX 12.0 70.0 unit 6 Living c 3000 117 124 0.502 7.0 Ox 0 VIFX 8.1 70.0 Unit 6 Living-A C 3000 117 124 0.477 7.0 Ox 0 VIFX 12.0 70.0 I Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FIR (fpm) (in) (in) Opening(in) Matl Trunk rb7 Ox 0 570 570 33.3 0.415 533 14.0 Ox 0 V1Fx rst48 • Trunk Htg Cig Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk rst48 Peak AVF 570 570 0.415 533 14.0 0 x 0 VinlFlx ' I i likddgh tsoft° Right-Suite@ Universal201717.0.23 RSU11033 2017-Sep-0708:16:11 ,ra�+A��'t ...Google DrivelDocumentslSonny'slRyman 6 Plex.rup Calc=MJB Front Door faces: E Page 6 i FORM R4.05-2014 TABLE 402.4J.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Ryman 6 Plex Builder Name: Street: Permit Office: Pasco City,State,Zip: Dade City,FL, Permit Number: Owner: Ryman 6 Plex Jurisdiction: Design Location: FL,Tampa COMPONENT CRITERIA CHECK Air barrier and thermal-barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope e contains continuous barrier. Breaks or-joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows,skylights and doors The space between"findow/dobr jambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation,insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts,utility penetrations, and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight,IC rated,and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed'boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. I Fireplace An air barrier shall be installed on fireplace walls.Fireplaces shall have gasketed doors 917/2017 7:58 AM EnergyGauge@)USA-RaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 Florida Department of Business and Professional Regulations Residential Whole Building Performance and Prescriptive Methods ADDRESS: Permit Number: Dade City,FL, MANDATORY REQUIREMENTS see individual code sections for full details. 401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law (Section 553.9085,Florida Statues)requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate compliance for the building;A copy of the EPL display card can be found in Appendix C. El R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.1 through R402.4.4. 0 R402.4.1 Building thermal envelope. The building thermal envelope shall comply wilt—hge—ctio-n—s R-4G2-.4Fl.-I-�i-n-d-fZ-40274-.I-.2.-The — sealing methods between dissimilar materials shall allow for differential expansion and contraction. • R402.4.1.1 Installation.The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed In accordance with the manufacturer's instructions and the criteria listed in Table 402.4.1.1,as applicable to the method of construction. Where required by the code official,an approved third party shall inspect all components and verify compliance, • R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones I and 2,and 3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an , approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3.Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off,and 6.Supply and return registers,If installed at the time of the test,shall be fully open. 0 R402.4.2 Fireplaces.New wood-burning fireplaces shall have tight-fitting flue dampers and outdoor combustion air. 0 R402.4.3 Fenestration air leakageWindows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400 or AAMA/WDMAIGSA 1011I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. 0 R402A.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm(0.944 Lts)when tested In accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential.All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. R403.1.1 Thermostat provision(Mandatory).At least one thermostat shall be provided for each separate heating and cooling system. El R403.1.3 Heat pump supplementary heat(Mandatory).Heat pumps having supplementary electric-resistance heat shall have controls that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. 0 R403.2.2 Sealing(MandatoryAll ducts,air handlers,and filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post-construction or rough-in testing below. Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either an energy rater certified in accordance with Section 553.99,Florida Statutes,or as authorized by Florida Statutes,to be'substantially leak free"by either of the following: 1. Post-construction test:Total leakage shall be legs than or equal to 4 cfm(113 L/mIn)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure.All register boots shall be taped or otherwise sealed during the test. 2. Rough-in test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(2513a)across the system,including the manufacturers air handler enclosure.All registers shall be taped or otherwise sealed during the test.If the air handler is not installed at the time of the test,total leakage shall be less than or equal to 3 cfm (85 Umin)per 100 square feet(9.29 m2)of conditioned floor area. Exceptions: 1. The total leakage test Is not required for ducts and air handlers located entirely within the building envelope. 2. Duct testing is not mandatory for buildings complying by Section R405 of this code. 9!712017 7:51 AM EnergyGauge@ USA-F1aRes2014 -Section k405.4.1 Com Page 1 of 3 FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) 11 R403.2.3 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. 11 R403.3 Mechanical system piping Insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41-C) or below 55°F(13°C)shall be insulated to a minimum of R-3.. R403.3.1 Protection of piping insulation. 13 R403.4.1 Circulating hot water systems(Mandatory). Circulating hot water systems shall be provided with an automatic or readily accessible manual switch that can tum off the hot-water circulating pump when the system is not in use. 13 R403.4.3 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shal ave heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3 Y2 inches(89 mm)in the hot water distribution line and cold water line located as close as possible to the storage tank. 11 R403.4.4 Water heater efficiencies(Mandatory). 0 R403.4.4.1 Storage water heater temperature controls R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the Intended use.The minimum temperature setting range shall be from I 00*F to 140°F(38°C to 60'C). R403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be fumed off.A separate valve shall be provided to permit the energy supplied to the main bumer(s) of combustion types of service water heating systems to be turned off. 0 R403.4.4.2 Water heating equipment Water heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1. R403.4.4.2.1 Solar water heating systems.Solar systems for domestic hot water production are rated by the annual solar energy factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Centeri Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors, and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol,Collectors in installed solar water heating systems should meet the following criteria: 1. Be installed with atilt angle between 10 degrees and 40 degrees of the horizontal;and 2. Be.installed at an orientation within 45 degrees of true south. [3 R403.5 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code,Residential or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. R403.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment. O. R403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and Indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1.This code does not allow designer safety factors,provisions for future expansion or other factors which affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. • R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load,but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.6,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load. 9/7/2017 7:51 AM EnergyGauge@ USA-FlaRes2014 -Section R405.4.1 Com Page 2 of 3 FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) 0 R403.6.1.1 Cooling equipment capacity.(continued) The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacture's expanded performance data shall be used to select cooling-only equipment.This selection shall be used to select cooling-only equipment.This selection s,h6ll,be based on the outdoor design dry bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower cfm provided by the expanded performance data, the design value for entering wet bulb temperature and the design value for entering dry bulb temperature. Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space. Exceptions: 1. Attached single-and multi-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida-registered engineer,in attached single-and multi-family units,the capacity of aquipmeriLma P be sized in accordance with good design practice. 0 R403.6.1.2 Heating equipment capacity R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section R403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load. R403.6.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.6.1. R403.6.1.2.3 Fossil fuel heating equipment The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.6.1. 0 R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. ❑ R403.7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the Commercial Provisions in lieu of Section R403. ❑ R403.8 Snow melt system controls(Mandatory). Snow and ice-melting systems,supplied through energy service to the building,shall include automatic controls capable of shutting off the system when the pavement temperature is above 55'F,and no precipitation is failing and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40oF. ❑ R403.9 Swimming pools,Inground spas and portable spas(Mandatory). The energy requirements for residential pools and inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSI/APSP-15.The energy requirements for portable spas shall be In accordance with ANSI/APSP-14, 0 R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on-off switch that is mounted outside the heater to allow shutting off the heater without adjusting the thermostat setting. R403.9.1.1 Gas and oil-fired pool and spa heaters. All gas-and oil-fired pool and space heaters shall have a minimum thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013 when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights. R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. 0 R403.9.2 Time switches. Time switches or other control method that can automatically turn off and on heaters and pumps according to a preset schedule shall be installed on all heaters and pumps,Heaters,pumps and motors that have built in timers shall be deemed in compliance with this equipment. Exceptions: • 1. Where public health standards require 24-hour pump operations. 2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation, 0 R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Outdoor pools deriving over 70 percent of the energy for heating from site-recovered energy,such as a heat pump or solar energy source computed over an operating season. ❑ RR404.1 Lighting equipment(Mandatory). A minimum of 75 percent of the lamps in permanently installed fighting fixtures shall be high-efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps. Exception: Low-voltage lighting shall not be required to utilize high-efficacy lamps. 0 R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights ❑ R405.2 Performance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R-6. 0 R405.2.1 Performance ONLY. Ceilings shall have minimum insulation of R-19.Where single assemby of the exposed deck and beam type or . concrete deck roofs do not have sufficent space,R-10 is allowed. 9/7/2017 7:51 AM EnergyGauge@ USA-FlaRes2014 -Section R405,4.1 Com Page 3 of 3 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the EnergyPerformance Index,the more efficient the home. Dade City, FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single-family-or-multiple-family Multifamily a.Concrete Block-Int Insul,Exterior R=5.0 3114.00 ftZ b- rame-Wood,-Adjacent R=1y.0-'I-512:00-t2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 12 d.N/A R= ft2 10.Ceiling Types Insulation Area 5. Is this a worst case? No a.Under Attic(Vented) R=30.0 6576.00 ftZ 6. Conditioned floor area(ft2) 6576 b.N/A R= ft2 7. Windows" Description Area c.N/A R= ft2 a. U-Faclor. Dbl,U=0.30 522.00 ftZ 11.Ducts R ft2 a.Sup:Attic,Ret:Attic,AH:Garage 6 200 SHGC: SHGC=0.26 b. U-Factor: N/A ft2 SHGC: 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a.Central Unit 106.2 SEER:14.00 SHGC: d. U-Factor. N/A ft2 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Strip Heat 106.2 COP:1.00 Area Weighted Average Overhang Depth: 1.000 ft. Area Weighted Average SHGC: 0.260 8. Floor Types Insulation Area 14.Hot water systems Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 6576.00 ft2 a.Electric EF:0.95 b.NIA R= ft2 b. Conservation features c.N/A R= ft2 None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Esr Construction through the above energy saving features which will be installed (or exceeded) 0�� = AT6 ,y o in this home before final inspection. Otherwise,a new EPL Display Card will be completed y',, '''�%' based on installed Code compliant features. Builder Signature: Date: kill: Address of New Home: City/FL Zip: COS *Note: This is not a Building Energy Rating. If your Index is below 70,your home may qualify for energy efficient mortgage(EEM)incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation,.contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 9/7/2017 7:50 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential.Performance Method Project Name: Ryman 6 Plex Builder Name: Street: Permit Office: Pasco City,State,Zip: Dade City,FL, Permit Number: Owner. Ryman 6 Plex Jurisdiction: Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2 1. New construction or existing New(From Plans) 9. Wall Types(4626.0 sqft.) Insulation Area -2.-Single-family-or-multiple-family-Multi=family - -a.Concrete Block-Int Insul,Exterior R=5.0 3114.00 ft' 5--Fr-a-m-e-WO-0-d,-Adjacent-------R=71-1-.0--l-512-.00-ft-- 3. Number of units,if multiple family I c.N/A R= ft2 4. Number of Bedrooms 12 d.N/A R= ft2 10.Ceiling Types (6576.0 sqft.) Insulation Area 5. Is this a worst case? No a.Under Attic(Vented) R=30.0 6576.00 ft' 6. Conditioned floor area above grade(ft,') 6576 b.NIA R= ft2 Conditioned floor area below grade(ft) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(522.0 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Garage 6 200 a. U-Factor: Dbl,U=0.30 622.00 ft2 SHGC: SHGC=0.26 JI2 12.Cooling systems kBtu/hr Efficiency b. U-Factor: N/A SHGC: a.Central Unit 106.2 SEER:14.00 c. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft21 a.Electric Strip Heat 106.2 COPA.00 SHGC: Area Weighted Average Overhang Depth: 1.000 ft. Area Weighted Average SHGC: 0.260 14.Hot water systems & Floor Types (6576.0 sqft.) Insulation Area a.Electric Cap:40 gallons EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 6576.00 ft2 b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat 1\Glass/Floor Area: 0.079 Total Proposed Modified Loads: 166.75 PASO Total Baseline Loads: 170.26 Review of the plans and 14.113 S7:qT s and pecifications covered by I hereby certify that the W;4 "e this calculation are in compliancew*th the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: Before construction is completed of 4-10- DATE. this building will be inspected for compliance with Section 653.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. QQD Wt.IV OWNER/AGENT: BUILDING OFFICIAJ : DATE: DATE: - Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402A.1.1 and an envelope leakage test report in accordance with R402.4.1.2. - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested In accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house. 917/2017 7:49 AM EnergyGauge@ USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 FORM R405-2014 PROJECT Title: Ryman 6 Plex Bedrooms: 12 Address Type: Street Address Building Type: User Conditioned Area: 6576 Lot# Owner: Ryman 6 Plex Total Stories: I Block/SubDivision: #of Units; 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: Permit Office: Pasco Cross Ventilation: No County: Pasco Jurisdiction: Whole House Fan: No City,State,Zip: Dade City, Family Type: Multi-family FL, New/Existing: New(From Plans) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp v Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Tampa FL—TAMPA—INTERNATI 2 39 91 70 75 645.5 54 Medium BLOCKS Number Name Area Volume Blockl 6576 52608 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated Main 6576 52608 Yes 12 12 1 Yes Yes Yes FLOORS Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio Main 346 ft 0 6576 ft2 0 0 1 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 6930 ft2 0 ftz Medium 0.9 N 0.9 No 0 18.4 ATTIC Type Ventilation Vent Ratio(I in) Area RBS IRCC I Full attic Vented 300 6576 ft2 Y N CEILING Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) Main 30 Blown 6576 W 0.1 Wood 9f7/2017 7.49 AM EnergyGauge(&USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 4 FORM R405-2014 WALLS VFAdjacent Space Cavity Width Height Sheathing Framing Solar Below 9--orrit-Ta-Wall-T-ype R-Value-F-t-In-F-t-in-Area-R--Value-Fraction-Absor-�Grade%- I N Exterior Concrete Block-Int Insul Main 5 162 0 9 0 1458.0 ft' 0 0 0.8 0 2 E Exterior Concrete Block-Int Insul Main 5 47 0 9 0 423.0 ft2 0 0 0.8 0 3 S Exterior Concrete Block-Int Insul Main 5 90 0 9 0 810.0 ft2 0 0 0.8 0 4 W Exterior Concrete Block-Int Insul Main 5 47 0 9 0 423.0 ft2 0 0 0.8 0 5 Garage Frame-Wood Main 11 168 0 9 0 1512.0 ft2 0 0.25 0.8 0 DOORS -7 # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In S Wood Main None .39 18 7 126 ft2 2 Wood Main None .39 17 6 7 122.5 ft2 WINDOWS Orientation shown is the entered,Proposed orientation. Wall Overhang V # Ornt ID Frame Panes NFRC; U-Factor SHGC Area Depth Separation Int Shade Screening I n I Metal Low-E Double Yes 0.3 0.26 120.0 ft' I ft 0 in 1 ft0in Drapes/blinds None 2 n 1 Metal Low-E Double Yes 0.3 0.26 252.0 ft2 1 ft 0 in I ft0in Drapes/blinds None 3 e 2 Metal Low-E Double Yes 0.3 0.26 15.0 f17 I ft0in I ftoln Drapes/blinds None 4 S 3 Metal Low-E Double Yes 0.3 0.26 120.0 ft' I ft 0 in I ft0in Drapes/blinds None 5 W 4 Metal Low-E Double Yes 0.3 0.26 15.0 ft2 1 ft0in I ftoln Drapes/blinds None GARAGE Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall insulation 1 382.8 ft2 384 ft2 64 ft 8ft 1 INFILTRATION Scope Method SLA CFIVI 50 ELA EqLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000254 4384 240.68 452.63 .1906 6 HEATING SYSTEM V # System Type Subtype Efficiency Capacity Block Ducts I Electric Strip Heat None COPA 106.2 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Plow SHR Block Ducts I Central Unit Split SEER:14 106.2 kBtu/hr 3186 cfm 0..8 1 sys*1 9f7/2017 7:49 AM EnergyGauge@ USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 4 FORM R405-2014 HOT WATER SYSTEM System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 40 gal 150 gal 120 deg None SOLAR HOT WATER SYSTEM VFSEC Collector Storage Cart # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS Supply­�----Return-- ir--CE HVAC# Location R-Value Area Location Area Leakage Type Handier TOT . OUT QN RLF Heat Cool I Attie 6 200 ft2 Attic 100 ft2 Prop.Leak Free Garage cfm 197.3 cfm 0.03 0.60 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Cooling n HF b H Mar JXJ Aprr I I May rj Jun Aug Sep IXI Oct M Nov H Dec Heating Jan Feb X Mar A Jun 1XI ijuU11 rl Aug Sep Oct X Nov Dec Venting Jan Feb Mar Apr May Jun Jul Aug rl Sep Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(VVEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 9/7/20I7 7:49 AM EnergyGauge@ USA-FlaRes20114 Section R405.4.1 Compliant Software Page 4 of 4 wrightsoft- Project Summary Job: Ryman 6 Plex Date: Sep 06,2017 Unit I By: DJM Priijecl: finfofffititldfi.- ':' For: Ryman 6 Plex Dade City,FL Notes: "D Wgi ffininf6rotatibn q . Weather: Tampa Intl AP,FL, US Winter Design Conditions Summer Design Conditions Outside db 43 OF Outside db 91 OF Inside db 70 OF Inside db 75 OF Design TD 27 OF Design TD 16 OF Daily range L Relative humidity 50 % Moisture difference 54 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 10083 Btuh Structure 10451 Btuh Ducts 2317 Btuh, Ducts 3367 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 12400 Btuh Use manufacturers data n Rate/swing multi tier 0.96 Infiltration Equipment load 13321 Stuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2570 Btuh Ducts 767 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling (none) Area(ft2) 1116T 1108 Equipment latent load 3337 Btuh Volume(IF) 9693 9693 Air changes/hour 0.43 0.23 Equipment Total Load(Sen+Lat) 16658 Btuh Equiv.AVF(cfm) 70 37 Req.total capacity at 0.80 SHR 1.4 ton Heating Equipment Summary Cooling Equipment Summary Make Make Carrier Trade 5 KW Trade CARRIER AIR CONDITIONING Model Cond 24ACB318ABN32 AHRI ref Coll FB4CNP018L AHRI ref 9859025 Efficiency 100 EFF Efficiency 11.5 EER, 14 SEER Heating input 3.6 kW Sensible cooling 13680 Btuh Heating output 12409 Btuh Latent cooling 3420 Btuh Temperature rise 20 OF Total cooling 17100 Btuh Actual air flow 570 cfm Actual air flow 570 cfm Air flow factor 0.046 cfm/Btuh Air flow factor 0.041 cfm/Btuh Static pressure 0.53 in H2O Static pressure 0.53 in H2O Space thermostat Load sensible heat ratio 0.81 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Rfght-SulleO Universal 201717.0.23 RSU1 1033 2017-Sep-07 08:16:11 ! Page IA5 n yyn . p ronooracs: E Project Summary Job: Ryman 6 Plex wrightSoft# Date: Sep 06,2017 Unit 2 y For: Ryman 6 Plex Dade City,FL Notes: Desiqn,l on Weather: Tampa Intl AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 43 OF Outside db 91 OF Inside db 70 OF Inside db 75 OF Design TD 27 OF Design TD 16 OF Daily range L Relative humidity 50 % Moisture difference 54 gr/ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 6111 Btuh Structure 8327 Btuh Ducts 2331 Btuh Ducts 3390 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 8442 Btuh Use manufacturer's data n Rate/swing multiplier 0.96 Infiltration Equipment sensible load 11295 Btuh. Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 1846 Btuh Ducts 814 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling (none) Area(ft2) 1090 1090 Equipment latent load 2660 Btuh Volume(ft3) 9693 9693 Air changes/hour 0.20 0.11 Equipment Total Load(Sen+Lat) 13955 Btuh Equiv.AVF(cfm) 33 18 Req.total capacity at 0.70 SHR 1.3 ton Heating Equipment Summary Cooling Equipment Summary Make Make Carrier Trade 5 KW Trade CARRIER AIR CONDITIONING Model Cond 24ACB318ABN32 i AHRI ref Coil FB4CNP018L AHRI ref 9859025 Efficiency 100 EFF Efficiency 11.5 EER, 14 SEER j Heating input 2.5 kW Sensible cooling 11970 Btuh Heating output 8448 Btuh Latent cooling 5130 Btuh Temperature rise 13 OF Total cooling 17100 Btuh Actual air flow 570 cfm Actual air flow 570 cfm Air flow factor 0.068 cfm/Btuh Air flow factor 0.049 cfm/Btuh Static pressure 0.53 in H2O Static pressure 0.53 in H2O Space thermostat Load sensible heat ratio 0.81 i i Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2017-Sep-07 08: e Rig ht-Suite®Universa12017 17.0.23 RSU11033 Pagaget rf 14,,,Google Dr1ve1DocumentS1Sonny's%Ryman 6 Plex.rup calo=Mia Front Door faces: E Job: Ryman 6 Plex welghtsoft. Project Summary Date: Sep 06,2017 Unit 3 By: DJM P oledi W6im­a' d6-'n-'- r For: Ryman 6 Plex Dade City,FL Notes: D6 dn".I n f o • Weather: Tampa Intl AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 43 OF Outside db 91 OF Inside db 70 OF Inside db 75 OF Design TD 27 OF Design TD 16 OF Daily range L Relative humidity 50 % Moisture difference 54 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 6111 Btuh Structure 8327 Btuh Ducts , 2331 Btuh Ducts 3390 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 8442 Btuh Use manufacturer's data n Rate/swl multiplier 0.96 'in Infiltration Equipmen?sens! le load 11295 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 1846 Btuh Ducts 814 Btuh Central vent(0 cfm) 0 Btuh none) Area(ft) Heatin I 09T Cool I 09m T Equi (pment latent load 2660 Btuh Volume(fP) 9693 9693 Air changes/hour 0.20 0.11 Equipment Total Load(Sen+Lat) 13955 Btuh Equiv.AVF(cfm) 33 18 Req.total capacity at 0.70 SHR 1.3 ton Heating Equipment Summary Cooling Equipment Summary Make Make Carrier Trade 5 KW Trade CARRIER AIR CONDITIONING Model Cond 24ACB318ABN32 AHRI ref Coll FB4CNP018L- AHRI ref 9859025 Efficiency 100 EFF Efficiency 11.5 EER, 14 SEER Heating input 2.6 kW Sensible cooling 11970 Btuh Heating output 8448 Btuh Latent cooling 5130 Btuh Temperature rise 13 OF Total cooling 17100 Btuh Actual air flow 570 cfm Actual air flow 670 cfm Air flow factor 0.068 cfm/Btuh Air flow factor 0.049 cfm/Btuh Static pressure 0.53 in H2O Static pressure 0.63 in H2O Space thermostat Load sensible heat ratio 0.81 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Right-Suile(D Universal 2017 MOM RSUI 1033 2017-Sep-07 08:16:11 ...Google DrivelDocurnentskSonny's%Ryman 6 Plex.rup Cale=MJ8 Front Door faces: E Page 3 Job: Ryman 6 Plex wrlghtsoW Project Summary Date: Sep 06,2017 Unit 4 By: DJM For: Ryman 6 Plex Dade City,FL Notes: n Weather: Tampa Intl AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 43 OF Outside db 91 OF Inside db 70 OF Inside db 75 OF Design TD 27 OF Design TD 16 OF Daily range L Relative humidity 50 % Moisture difference 54 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 6111 Btuh Structure 8327 Btuh Ducts 2331 Btuh Ducts 3390 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 8442 Btuh Use manufacturer's data n Rate/swingmultiplier 0.96 Infiltration Equipment load 11295 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 1846 Btuh Ducts 814 Btuh Central vent(0 cfm) 0 Btuh HeatingCoaling (none) Area(ft2) log 1090 Equipment latent load 2660 Btuh Volume(ft3) 9693 9693 Air changesthour 0.20 0.11 Equipment Total Load(Sen+Lat) 13956 Btuh Equiv.AVF(cfm) 33 18 Req.total capacity at 0.70 SHR 1.3 ton Heating Equipment Summary Cooling Equipment Summary Make Make Carrier Trade 5 KW Trade CARRIER AIR CONDITIONING Model Cond 24ACB31BABN32 AHRI ref Coil FB4CNP018L AHRI ref 9859025 Efficiency 100 EFF Efficiency 11.5 EER, 14 SEER Heating input 2.5 kW Sensible cooling 11970 Btuh Heating output 8448 Btuh Latent cooling 6130 Btuh Temperature rise 13 OF Total cooling 17100 Btuh Actual air flow 570 cfm Actual air flow 570 cfm Air flow factor 0.068 cfm/Btuh Air flow factor 0.049 cfm/Btuh Static pressure 0.53 in H2O Static pressure 0.53 in H2O Space thermostat Load sensible heat ratio 0.81 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2017-Sep-07 D8:16:11 44+ WrtghtSOft' Right,SulteS universal 2017 17.0.23 RSU1 1033 Page 4 G..gi.Driv.1Docurnenfs%Sonnys1Ryrnan 6 Plex.rup Cato=MJ8 Front Door faces: E Pro t Summary Job: Ryman 6 Plex wrightsoft- j ec Date: Sep 06,2017 Unit 5 By: DJM Pr. ofttWar For: Ryman 6 Plex Dade City,FL Notes: Weather: Tampa Intl AP,FL, US Winter Design Conditions Summer Design Conditions Outside db 43 OF Outside db 91 OF Inside db 70 OF Inside db 75-OF Design TD 27 OF Design TD 16 OF Daily range L Relative humidity so % Moisture difference 54 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 6111 Btuh Structure 8327 Btuh Ducts 2331 Btuh Ducts 3390 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh {crone) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 8442 Btuh Use manufacturer's data n Rate/swingmultiplier 0.96 Infiltration Equipment sensible load 11295 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 1846 Btuh Ducts 814 Btuh Heatin Coolin Central vent(0 cfm) 0 Btuh Area(ft2) 9 (pone) 1090 1090 Equipment latent load 2660 Btuh Volume(111) 9693 9693 Air changes/hour 0.20 0.11 Equipment Total Load(Sen+Lat) 13955 Btuh Equiv.AVF{cfm) 33 18 Req.total capacity at 0.70 SHR 1.3 ton I I Heating Equipment Summary Cooling Equipment Summary Make Make Carrier Trade 5 KW Trade CARRIER AIR CONDITIONING Model Cond 24ACB318ABN32 AHRI ref Coil FB4CNP018L AHRI ref 9859025 Efficiency 100 EFF Efficiency 11.5 EER, 14 SEER Heating input 2.5 kW Sensible cooling 11970 Btuh Heating output 8448 Btuh Latent cooling 5130 Btuh Temperature rise 13 OF Total cooling 17100 Btuh Actual air flow 570 cfm Actual air flow 570 cfm Air flow factor 0.068 cfm/Btuh Air flow factor 0.049 cfm/Btuh Static pressure 0.53 in H2O Static pressure 0.53 in H2O Space thermostat Load sensible heat ratio 0.81 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Right-Suite®Universal 201717.0.23 RSUI 1033 2017-Sep-07 OB:16:11 Page 5 Gcogle DrivelDocumentskSonny'slRyman 6 Plex.rup Cato=MJS Front Door faces: E Job: Ryman 6 Plax wrightsoftv Project Summary Date: Sep 06,2017 Unit 6 By: ON Project [fif6ft'atibri". . For: Ryman 6 Plex Dade City,FL Notes: Weather: Tampa Intl AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 43 OF Outside db 91 OF Inside db 70 OF Inside db 75 OF Design TD 27 OF Design TD 16 OF Daily range L Relative humidity 50 % Moisture difference 54 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 10083 Btuh Structure 10451 Btuh Ducts 2317 Btuh Ducts 3367 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (gone) (none) Humidification 0 Btuh Blower 0 Btuh plping 0 Btuh Equipment load 12400 Btuh Use manufacturer's data n Rate/swin multiplier 0.96 Infiltration Equipment sensible load 13321 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 90 Structure 2570 Btuh Ducts 767 Btuh Heating Cooling Central vent(0 cfm) 0 Btuh oy (none) Area(ft2) 1108 11 Equipment latent load 3337 Btuh Volume(fl?) 9693 9693 Air changes/hour 0.43 0.23 Equipment Total Load(Sen+Lat) 16658 Btuh Equiv.AVF(cfm) 70 37 Req.total capacity at 0.80 SHR 1.4 ton Heating Equipment Summary Cooling Equipment Summary Make Make Carrier Trade 5 KW Trade CARRIER AIR,CONDITIONING Model Cond 24ACB31BABN32 AHRI ref Coil FB4CNP018L AHRI ref 9859025 Efficiency 100 EFF Efficiency 11.5 EER, 14 SEER Heating input 3.6 kW Sensible cooling 13680 Btuh Heating output 12409 Btuh Latent cooling 3420 Btuh Temperature rise 20 OF Total cooling 17100 Btuh Actual air flow 570 cfm Actual air flow 570 cfm Air flow factor 0.046 cfm/Btuh Air flow factor 0.041 cfm/Btuh Static pressure 0.53 in H2O Static pressure 0.53 in H2O Space thermostat Load sensible heat ratio 0.81 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Right-SulleOD Universal 2017 17.0.23 RSU1 1033 2017-Sep-07 08:16:11 1456....Google Dflve1DocUmentsXSonny4skRyrnan 6 Plex.rup Cate=MJ8 Front Door faces; E Page 6 N .. .. ....:..........,,,:w,:.•,t'•r,•;;,^,'I,. >�r,..!:tI:1Ia L.!larl.i:I"i"i j%.•r!,IIy,nf:l{s'��r�':LnI:l,i,;Il II'Iri r;•s,:u..rs.raxlW,�•<;�4 1u.7;--„c..'.11.",.'....ci`'F>.^:1=w,�:","�..-',n�:.:.r..c-3z rx *1.P.•.:v.+._."Ic„--<.v a,:d t.:$+•_ i:.:!:;F.:;Wr:-,:'.:`:�:Ps..-,::na.•'1.::!.m:,::�:-_:_a!_I�_.-�._:-�.-.".-�._.�- ME ul& .,.:s.I,l 111 �> s g�1. of .. � .-. �. .:, :. ,e Fll e:l^:I!I,,,,;r I:I,.y. ..n. ..,;.., .>�.�i, .:,.e•+R Z. __ =L::. I" a ,I ig I, Jl µfm I 1 i ... .... ...I I... f ,.�Cp, I. .•�LI'u ..a a. :.err e•+.LI�...h �r a .,� 5'il�i;l:l��ul . ulq t;•�d„:.:.;�..1�.;,;.,pr;f...... _ - r �,.,�..:r'.. �,�� !{la,l:,, !G�.II,II, ,f ui,•. d'J�1�� -s•� s? '"=•�'',I -- ��.a°m- ��'�l' - :pz i '. I _!,1.1 ,III :,�:_.,��, �,.�,•1r,�•tea:,�t - ---- .�v�;: =- ., `�: 1 - .. ,. F',L•� .�.11:1 I L,31 t 1 I, /RW I,,IL!..I!tly1.'y,-.....tih�:.o 'I.xV ..1 tl"I _ ;i^,� R.'s I!'v?1R.A�� .� r`r 145��� k*uF:.e II 1• i I. I Y} I .L,I���II,• I,L:a I fo. I. ... ., ....,.- r I,II'•:. I 'ilh,� Irr.,J: �°":. °::f«:a S.>.a,,`~ :d;� n' 'T I I I'il.l ,I �, y. ?^_ed;. r. ,.,'L•' s.. - - �x-==7,:� - - r ". _ o1.i',�f JU II I I ,'� �II f ,.:,s%:. �.•f_.5 .i,.•=,g�xr.r,��h '" _- :":::ii:r,::;::!;a�'" `�+..:.. - .,.E ..M „ II .,.I..I (,Ip� IIII •,;�:�;., ,.Ii: .,R.;°��:t�.:,x'I -.f, ,� Y qll l ,II't,l, dltiha�ll,l�l= � ; t.l• II r^ f. . �x�s:L:,llll'un,. V41� ''�:4.:111,1, pp,+a7i,Id >�4.'= r"s=.y, .a3•e.�� _ _ �,:��!_:..,..;,::; ,¢ !7k''4: e r• - ,,r' It.YI I fi3• - - •'m III I .el LL 7i- t.�,�` �r.e• jl'!i�liai. u3.F,c.,!: •1'III IIII I�I.I'lllirll. w>„3,.'.".!•:'�:S�Y"% -__ ran:.,�'e�r' - .IIII.II,I.hII��9;tII.s�:.IIIITI:__ .ys;•a:• - __ - _ �i. :�.:� r,l x'idl — sa. IIII';Illlla-,g,ll M-,! .,;=.t. ;',P t'.;° __.yi i;i �_=-61! ,„'}.II :•/. 'al - .rllll llli Nl lullil;l�ijc h-"4;. _7,°: =` - !t'rv!hiidlri[i'r t• r,6iu 'p:;i�Ih16�1gI;IP i�u` +:a;�.�•rs�'� -_ i+l�i_�'=_':".� �� N:Ij'hti`!.'I!IIII ni I•G�I I,I '�x�n,y>>,•',-,-'`51-.ae - _ -_:-1::. 4jk - L111,IIIdIl1y �L,,N1,1:�141��t��'Fh. '::'w?ui•- It`"'='''�lioa :_ H J IIII! Ir 1'I '- U . II I�'_ IL'II:IIIrlhs!I�je!i�4c3n-t.'•y�ss-' !�,�:r,':::al.:_. Job M Ryman 6 Plex Scale: 1 :270 Performed by®JM for: Page 1 Ryman s Plex Right-SuiteO Universal 2017 Dade City,FL 17.0.23 RSU11033 2017-Sep-07 08:17:04 currents\Sonny's\Ryman 6 Plex.ru Duct System Summary Job: Ryman 6 Plex wrightso Date: Sep 06,2017 Unit 1 By: DJIVI Proiect-inf6rmati6n For: Ryman 6 Plex Dade City, FL Heating Cooling External static pressure 0.53 in H2O 0.53 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.53 in H2O 0.53 in H2O Supply/return available pressure 0.336 0.194 in H2O 0.336 0.194 in H2O Lowest friction rate 0.363 in/100ft 0.363 in/1 00ft Actual air flow 570 cfm 570 cfm Total effective length(TEL) 146 ft -tSu' ppy P "'Branch-Detalk-TAble"_., Design Htg Cig Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FIR (in) (in) Mat[ Ln(ft) Ln(ft) Trunk Unit 1 Bath 1 C 131 3 5 0.420 4.0 Ox 0 VlFx 10.0 70.0 Unit 1 Bath 2 h 412 19 16 OA51 4.0 Ox 0 VlFx 4.5 70.0 Unit I Bed 1 C 2264 92 93 0.376 6.0 Ox 0 VlFx 19.4 70.0 Unit 1 Bed 2 h 3580 165 107 0.363 8.0 Ox 0 VlFx 22.5 70.0 Unit I Kitchen C 2266 57 93 0.413 6.0 Ox 0 VlFx 11.3 70.0 Unit 1 Living c 3092 117 128 0.410 7.0 Ox 0 VlFx 12.0 70.0 Unit 1 Living-A c 3092 1 117 128 0.431 7.0 Ox 0 VIFx 8.0 70.0 JIM, MIT a IM F-fill • Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FIR (fpm) (in) (in) Opening(in) Matl Trunk rb3 Ox 0 570 570 53.3 0.363 533 14.0 Ox 0 VlFx rst49 A elurn Trunk D�fa il T40 ; " Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk rst49 Peak AVF 570 570 0.363 533 14.0 0 X 0 VInIFlx Sri + WrI9ht540ft* Right-Suite@ Universal 201717.0.23 RSU11033 2017-Sep-07 08:16:11 GoDgla DrivelDocumentsWonny'skRyman 6 Plax.rup Cale=IVIJB Front Door faces! E Page I Duct System Summary Job: Ryman 6 Plex wrightso Date: Sep 06,2017 Unit 2 By: DJM V.' For: Ryman 6 Plex Dade City, FL Heating Cooling External static pressure 0.53 in H2O 0.53 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.53 in H2O 0.53 in H2O Supply/return available pressure 0.390 0.140 in H2O 0.390 0.140 in H2O Lowest friction rate 0.420 in/100ft 0.420 in/1 00ft Actual air flow 570 cfm 570 cfm Total effective length(TEL) 126 ft ------ --=SubP . lyzWeiih -h c -D-eta H-T-a Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FIR (in) (in) Matt Ln(ft) Ln(ft) Trunk Unit 2 Bath 1 c 143 5 7 0.487 4.0 Ox 0 VlFx 10.0 70.0 Unit 2 Bath 2 h 462 31 20 0.520 4.0 Ox 0 VlFx 5.0 70.0 Unit 2 Bed 1 h 2259 153 120 0,436 7.0 Ox 0 VlFx 19.4 70.0 Unit 2 Bed 2 h 2238 151 105 0.420 7.0 Ox 0 VlFx 22.8 70.0 Unit 2 Kitchen C 2010 11 98 0.475 6.0 Ox 0 VlFx 12.0 70.0 Unit 2 Living c 2263 110 110 0.475 6.0 Ox 0 VlFx 12.0 70.0 Unit 2 Living-A c 2263 110 110 0.500 6.0 Ox 0 VlFx 8.1 70.0 ft ranc!,)--. -.R7e urn, Grille Htg Cig TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) -(ft) FIR (fpm) (in) (in) Opening(in) Mad Trunk rb2 Ox 0 570 570 33.3 0.420 533 14.0 Ox 0 VlFx rst47 Tr6hk Detaiftible-: ' Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfrill) (cfm) FIR (fpm) (in) (in) Material Trunk rst47 Peak AVF 570 570 0.420 533 14.0 0 x 0 VinIFlx 2017-Sep-07 08:16:11 WeIghtSOW Right-Sulte@univ.,sal20l7l7.0.23RSU110'33 Page 2 GOD91a DriveiDocurnentskSonny'slRyman 5 Plex.rup Cale=MJ8 Front Door faces: E ^ ^ ` ���� �����K� �� g��«�� �7� �w��& m��«�x�- Duct System Summary Date: Sop06,2017 Unit 3 By: muM . on Dade City,FL Heating Cooling External static pressure 0.53 in H2O 0.58 in H2O Pressure losses O hnH2O O huH2O Available static pressure 0.53 in H2O 0.58 in H2O Supply/return available pressure 0.839/0.181inH20 0.338/0.101inH20 Lowest friction rate 0.850 |n/100ft 0.359 in/100ft Actual air flow 570 uhn 570 uhn Total effective length(TEL) 148 M Design Htg Clg Design Diam HxW Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FR (in) (in) Mall Ln(ft) Ln(it) Trunk Grille Htg Clg TEL Design Veloc Diam HxW Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FIR (fpm) (in) (in) Opening(in) Mail Trunk Name Type W171171) (CfM) FIR (fpm) (in) (in) Material Trunk W mum-Suitem universal 2unnu.2unauI 1033 umr-Sep-u 08:16:11 ..'.Google DfivelDocurnentsisonny'Myrnan 6 Piex.rup Cate=mJ8 Front Door faces: E Page ^ . ` ` ��, ���� K� ��k�00��� �� u��a�� �� ~°,~ Duct Summary n�e' oppo�cm7 ^ � Unit 4 By: DJM Dade City, FL Heating Cooling External static pressure 0.53 in H2O 0.53 inH2U Pressure losses O in H2O 0 in H2O Available static pressure 0.53 in H2O 0.53 in H2O Supply/return available pressure 0.391 /8.138 |nH20 0.391/0.138inH20 Lowest friction rate 0.410 kl1O0# 0.416 in/100ft Actual air flow 570 ohn 570 uhn Total effective length(TEL) 127 ft Design Htg Clg Design Diam HxW Duct Actual Ftg.Eqv Name (Btuh) (cfm) Win) FIR (in) (in) Mail Ln(ft) Ln(ft) Trunk_ Grille Htg Clg TEL Design Veloc Diam HxW Stud/Joist Duct Name Size(in) (cfm) (cfm) (it) FIR (fpm) (in) (in) Opening(in) Mall' Trunk Name Type (cfm) (cfm) FIR Upm) (in) (in) Material Trunk n���x��mc �� xm��u mmm1 �� '�� ww m»m�o��om"es"mnn�uuonno��um Page ����-auuo/°orivmoocum"mmeuommnvmo"op/ex.ruo oum~wuo Front Door faces: s ^ ^ - , ���� U� ��8�00�K� �� �m�s�� �� Duct Summary �� o�0�cm7 ^ --^' — Unit 5 By: oxM For: Ryman 6 plex Dade City,FL. ------����� Heating Cooling External static pressure 0.53inH20 0.53inH20 Pressure losses 0 in H2O 0 hmH20 Available static pressure 0.53 in HZO 0.53 in H2O Supply/return available pressure 0.301 /O.138 /n H2O 0.391 /0.139 in H20 Lowest friction rate 0.410 in/100ft 0.418 in/100ft Actual air flow 570 ohn 570 ohn Total effective length(TEU 127 ft . Design Htg Clg Design Diam HxW Duct Actual Ftg.Eqv Name (13tuh) (cfm) (cfm) FIR (in) (in) Mail Ln(ft) Ln (ft) Trunk Grille Htg Cig TEL Design Veloc Diam HxW Stud/Joist Duct Name Size(in) (cfm) (cfm) (it) FIR (fpm) (in) (in) Opening(in) Mail Trunk Name Type (cfm) Win) FR Upm) (in) (in) Material Trunk / | / / ( | i | ' ' | | | � i / ! � 2017-aep-0708:16x1 ' 44 Right-S.It.@universal 201717.0,23 RSU11033 Page | aoonle opie,.ruo mlc~Mm Front Door faces: c ! ' ' � Duct System Summary Job: Ryman 6 Plex wrightso Date: Sep 06,2017 Unit 6 By: DJIVI ---P.Mect lblf&hfati§#� For: Ryman 6 Plex Dade City, FL Heating Cooling External static pressure, 0.53 in H2O 0.53 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.53 in H2O 0.53 in H2O Supply/return available pressure 0.392 0.138 in H2O 0.392 0.138 in H2O Lowest friction rate 0.415 in/100ft 0.415 in/1 00ft Actual air flow 570 cfm 570 cfm Total effective length(TEL) 128 ft AI-E! Design Htg C19 Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FIR (in) (in) Mat[ Ln(ft) Ln(ft) Trunk Unit 6 Bath 1 c 134 3 6 0.489 4.0 Ox 0 VlFx 10.0 70.0 Unit 6 Bath 2 h 412 19 16 0.522 4.0 Ox 0 VlFx 5.0 70.0 Unit 6 Bed I c 2319 92 96 0.433 6.0 Ox 0 VlFx 20.4 70.0 Unit 6 Bed 2 h 3580 165 110 0.415 8.0 OX0 VlFx 24.4 70.0 Unit 6 Kitchen c 2321 57 96 0.477 6.0 Ox 0 VlFx 12.0 70.0 Unit 6 Living c 3000 1171 124 0.502 7.0 Ox 0 VlFx 8.1 70.0 Unit 6 Living-A c 3000 117 124 0.477 7.0 Ox 0 VIFX 12.0 70.0 h Grille Htg Cig TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FIR (fpm) (in) (in) Opening(in) Matl Trunk rb7 Ox 0 570 570 33.3 0.415 533 14.0 Ox 0 VlFx rst48 Trunk Htg Cig Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk rst48 Peak AVF 570 570 0.415 533 14.0 0 x 0 VInlFIx 2017-Sep-07 013:1611 WIhIghtsOft Right-Suitet7Unlversa1201717.0.23 RSU1 1033 Page 6 14M Google DrivelDocurnentsksonny'sMyrnan 6 Plax.rup Caic=Mia Front Door faces: E 1 i9gILq , y. City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: ( a4daCC Ar�\ Date Received: Site: Permit Type: Approved w/no comments:❑ Approved w/the below comments: Denied w/the below comments: ❑ This comment sheet shall be kept with the permit and/or plans. Kalvin Switzer—Pl s Examiner Date C. tractor an wner� n cnt� esent) PASCO COUNTY ' DEVELOPMENT SERVICES c� Date: 12/28/2018 PAS:C 8731 Citizens Drive CothN (.:TLOAIDA New Port Richey, FL 34654 OPEN Srncrs..UrnRav i.Ptncs.- 727-847-2411 * NOT A PERMIT Receipt* 1819124 FEE DESCRIPTION ACCOUNT CODE UNITS INVOICE# FEE AMOUNT PAID RECEIPT# DATE Impact Fee Residential Solid 24503100-329010 1.00 1414523 $0.52 $0.52 1819124 12/28/18 Waste Condo,Multi-Family MH in Park,per Unit 0226210300006000330. TOTALS: $0.52 $0.52 Receipt# Paid By Check# CC Auth# Cashier ID Workstation Receipt Date Amt Paid 1819124 Cash 534 BCCCP15W 12/28/2018 $0.52 Total Payments: $0.52 Payor _ Address Phone RYMAN CONSTRUCTION P#19006 6768 BASSWOOD CIRCLE ZHLLS Comments- 022621030.0000000330 while you will be paying your bill with Pasco County Development Services,the full amount of the credit card or a-check fees,NOT shown above,is collected by First Billing payment services. MyReports/reports//PASCOPROD/PASCO/ReceiptPOS V6.rpt 12/28/2018 Page 1 of 1 5335 - 8TH STREET (813)780-0020 CERTIFICATE OF OCCUPANCY RYMAN CONS Address: 6768 BASSWOOD CIRCLE Owner: 36413 STATE I ZEPHYRHILLS, FL. ZEPHYRHILLS Subdiv: DRIFTWOOD work Type: 104-NEW CON Parcel: 02-26-21-0300-00000-0330 Construction Type: NOT APPLICABLE [] Sprinklers Use Classification: NOT APPLICABLE Permit Number: 19006 D 12/28/2018 ISSUED B : , BUILD14 WATER MUST BE CHANGED OVER WITH YQ pAYs QF I` GARBAGE DEPOSIT MUST BE APPLIED R,ppj0_R TO 1S4