Loading...
HomeMy WebLinkAbout17-19009 CITY OF ZEPHYRHILLS 5335-8TH STREET • (813)780-0020 19009 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL PERMIT INFORMATION LOCATION INFORMATION— Permit#:19009 Issued: 11/06/2017 Address: 6758 BASSWOOD CIRCLE Permit Type: GENERAL BUILDING PERMIT ZEPHYRHILLS, FL. Class of Work: 104-NEW CONST TRI 3/4 UNIT Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 135,450.00 Total Fees: 6,693.73 Subdivision: DRIFTWOOD Amount Paid: 5,450.98 Date Paid: 11/06/2017 Parcel Number: 02-26-21-0300-00000-0350 CONTRACTOR INFORMATION OWNER INFORMATION Name: RYMAN CONSTRUCTION OF FLORIDA IN, Name: RYMAN CONSTRUCTION INC Addr: 36413 S.R. 54 WEST Address: 36413 STATE ROAD 54 ZEPHYRHILLS, FL. 33541 ZEPHYRHILLS FL 33541-2275 Phone: (813)782-0825 Lic: Phone: 813-782-0825 Work Desc: CONSTRUCT TRIPLEX 1,466 SQ FT APPLICATION FEES BUILDING FEE 687.92 ELECTRICAL FEE 134.10 PLUMBING FEE 89.40 MECHANICAL FEE 62.58 SEWER CONNECTION RESIDEW 2,010.00 WATER CONNECTION RESIDENT 641.00 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 FIRE INSPECTION FEES 12.50 FIRE INSPECTION FEES 76.32 PARK FEES SF 769.56 TRAFFIC IMPACT FEE 99% 1,640.43 TRAFFIC IMPACT FEE 1% 16.57 Z � Inspections Required FOOTER 2ND ROUGH PLUMB MIS INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL Misc.- DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. ONTRAC GNATURE PERMIT OFFI EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER 6758 BASSWOOD CR-RYMAN CONSTRUCTION-1466 sq ft Column 13 SO.FEET PRICE MAIN OR LIVING: 1,466 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 135,450.00 contract price FEE SHEET $ 596.00 ADDRESS $ 40.00 DRIVEWAY 1 $ 40.00 BUILDING: $ 687.92 ELECTRICAL: $ 134.10 PLUMBING: $ 89.40 MECHANICAL: $ 62.58 SUB-TOTAL $ 974.00 TOTALI$ 974.00 SEWER: $ 2,010.00 WATER: $ 641.00 IRRIGATION: $ - TOTAL: $ 2,651.00 WATER METER:I MASTER METR IRRIGATION METER I$ FIRE DEPARTMENT FEES PLANS TOTAL: $ 76.32 INSPECTION TOTAL: $ 12.50 PERMIT TOTAL TOTAL:l$ 88.82 PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 51/o $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 4,267.17. PARK IMPACT FEES J$ 769.56 SIF'S: 100.0% $ 1.01/0 $ TOTAL: $ T I FS:l$ 1,657.00 25%due at permit pick up$414.25 75%$1,242.75 due before pre-meter 99%1$ 1,640.43 1%1$ 16.57, TOTAL: $ 6,693.73 c /�Y ILOgluq, City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: Date Received: �' uJZ Site: 'j 4-suoc)04 CYCLI , "Permit Type: Approved w/no comments:❑ Approved w/the below comments: / Denied w/the below comments: ❑ This comment sheet shall be kept with the permit and/or plans. /W iOw-n Kalvin Switzer lans Examiner Date ;actor o eowner wired whe c rnme s,at_�'pr esent) 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 , Building Department Date Received . Phone Contact for Permitting ( � -7 -- 0 Owner's Name it�Y1 ��svr�� �� -SA C• Owner Phone Number Owner's Address 1 sal` 5 �Q `A �' �''�`� Owner Phone Number i Fee Simple Titleholder Name I Owner Phone Number Fee Simple Titleholder Address s' cc l JOB ADDRESS LOT# a SUBDIVISION r' ��® PARCEL ID# 0 a-a b ' _ 00 00000 V o3 ! (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR ADD/ALT = SIGN = DEMOLISH INSTALL e REPAIR PROPOSED USE EE/ SFR Q COMM = OTHER TYPE OF CONSTRUCTION BLOCK • 0 FRAME = STEEL Q DESCRIPTION OF WORK BUILDING SIZE SQ FOOTAGE L.i U HEIGHT l BUILDING $ I 000 VALUATION'OF TOTAL CONSTRUCTION =ELECTRICAL $ AMP SERVICE = PROGRESS ENERGY Q�yf/aW.R.E.C. PLUMBING $ `Cf t1 =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION =GAS = ROOFING Q SPECIALTY = OTHER Tt � FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA DYES NA 0 v BUILDER' - COMPANY + Z:v1 CFJ e�5Ve UL ►r6 i/0�- SIGNATURE REGISTERED YV N I FEE CURREN ` Y/N Address J J�� 5 �5 1 License#S o ELECTRICIAN COMPANY c,�L C> E - '�r d - SIGNATURE kce� S REGISTERED Y/ N FEE CURREN /N_�] J Address !_ License# ( o V J PLUMBER COMPANY =3iS \l.Z � ?� , SIGNATURE REGISTERED Y/ N FEE CURREN LCMIN Address License# MECHANICAL COMPANY �V At1NJ & Al.( SIGNATURE REGISTERED Y/ N FEE CURREN N Address License# OTHER COMPANY dwa V'\ 2-00cli,Z1' SIGNATURE., REGISTERED Yf N FEE CURREN IEVN Address 6 Lt Z, i, , h,,115 AL 7 ( License# I C C&13a srs 0-T RESIDENTIAL Attach.(2)PIot:Plans;:(2)>sets ofBuilding Plans;.(1)'set'of-Energy Forms;R-O-W Permit for new.construction, m-Minimu ,..tenr(,10)working days after:submittal.date. Require&bnsite,'Construction Plans,Stormwater Plans w/Silt Fence installed, Sanityry.;Facilities.&;1.dumpstec;Site.Work'Permit for,subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new,construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of'Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500) ** Agent(for the contractor)'or Power of Attorney(for'the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers 1 _ Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW ,____ �....�....,+..�=.,.a_F.s..v.x�•+<_ vewc..zsr._��:a�.."�'ti5.._'tY:S25L!L:,".1si'_��_;�rwy" j NOTICE OF DEED RESTRICTIONS: 1 he undersigned understands that.this,permit maybe subject to"deed''-'restrictions" which may..be more:restrictive.than County regulations: Thef.undersign6d',assuatie- responsibility'for',compliance with'any applicable deed restrictions. UNLiCENSED CONTRACTORS AND CONTRACTOR RESPONSiBILITIES: If the owner hasp-hired-a- contractor or contractors to undertake work, they may be required to be.licensed in accordance with state and local regulations: If�the. contractor is not licensed as required by law, both the owner and,contractor.niay-be cited-�for''a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements::may.apply for.the' intended work, they are advised to corrtact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired,a contractor or contractors, he is advised to ;have the contractor(s). sign portions of the "contractor Block" of this application for which they will be responsible. If you, as'ithe owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled'to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change.:of° use in existing buildings, or expansion of:existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned,also understands, that such fees, as may be due, will tie identified L at the:time ofi permitting. It Is further understood that Transportation Impact Fees and Resource:Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of'occupancy or final power release, the fees must be.paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must,be paid prior to,permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION-LIEN LAW(Chapter 713, Florida Statutes, as amended): if valuation of work is$2,500.00 or more,..i certify that 1, the applicant, have been provided with a copy..of the "Florida-Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If thel applicant.is someone other than the "owner", I certify,that l have obtained a copy of the above described document and promise in good faith to deliver it to the"owner" prior to commencement. CONTRACTORS/OWNER'S AFFIDAVIT: 1 certify that all the information in this application is accurate and that all-work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation-has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that 1 understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions i must take to be in compliance. Such.agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands,WaterlWastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. ' - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. i understand that the following restrictions apply to the use of fill: Use of fill is not allowed in Flood Zone W"unless expressly permitted. If the fill material is to be l used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed.by the State of Florida. If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill1will be used only to fill the area within the stem wall. If fill material is to .be used in any area, 1 certify that use of such`fill will not adversely affect adjacent properties. If use of fill is found to adversely affect,adjacent properties, the owner maybe cited for violating, the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If i am the AGENT FOR THE OWNER, I, promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing const juction. i understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technicallcodes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued�shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is'commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety(90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAIi:URE TO RECORD A NOTICE OF COMMENCEMENT IifIAYj RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YO.UR,PROPERTY. IF YOU.'INTEND- O OBTAiN'FiitiiANCING, CONSULT WITH YOUR LENDER ORS AN ATTORNEY tEFORE.RECORDING YOUR NOTiCE OF COYU MENCEMENT. FLORIDA JURAT(F. .117.03)OWNER d a OR nd ENT (or rrt� �FS CONTRAC I sworbe t s Su sc r tl and sworn to(or rrm d)before met 's j 1 1 by L by I— Kw 44 All— Who is/are personally-known to me or has/have p oduced Who is/are pers . nown to me or has/have produced as identification. as Identification. I .�` -Notary Public Notary Public I Commission No. Commission No. i an ANNA MARIE LYNCH TERRY J ,,,,, Name of No r r ,tel�diBi4WOMI•Slaie of Florid,. " Name of Notary typ ,,_ c to y * * - � � Public-State,of Flonaa „ Commission#FF 958064 !•; ;• Commission#FF 958064 My Comm.Expires Apr 4.2020 e =:�9j, `o`er My Comm.Expires Apr 4,2020 °� Bonded through National Notary Assn '�i,�OF F4�,.�`, ue��ti+� Bonded through_National Notary Assn.. Single Family Dwelling Plan Review Comments 1. F.F.E. shall be a minimum of 8" above the road elevation and an engineered site plan. 2. Lots shall be graded to comply with R401.3 of the F.B.C. 3. Compaction test required if 24" or more of All dirt.is brought in at any one place. . 4. Tie in survey required before pouring concrete. 5. Driveways require Ia R.O.W. use permit. All 4 sides of driveway thru the sidewalk shall have expansion-material. 6. All setbacks_shall be met. 7. All property markers shall be uncovered and marked at time of first inspection. 8. -All A.D.A. requirements shall be met. 9. No electric,plumbing, mechanical, or framing shall be.covered without an inspection and approval first. 10. All Garages shall comply with section R302.6 of the F.B.C,. (Fire Separation). 11. Appliances shall not be installed in a location where subject to mechanical damage unless protected,by approved barriers. M303.4 of the F.B.0 12. Water heaters shall comply with section P607.3 of the F.B.C. 13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M1308.1 14.Return air in all bedrooms. F.B.C: M1620.4 15. Smoke detectors are to be installed-in accordance with R313.1 of the F.B.C. 16. All glazing requirements are to be in accordance with R308.4 of the F.B.C. 17. All means of egress are to.be in accordance with R3 11 of the F.B.C. 18: "Green gypsum board" shall not be used as a backer in showers or tubs. R702.4.2 F.,B.C: 19. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. ,20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating or appliances or.an attached garage. They shall be installed in accordance with the F.B.C. 21. All plumbing, mechanical, and electrical shall be separate from unit to.unit. This includes all underground plumbing and electric. 22. All 2008 N.E.C. Codes will be enforced. 23. Tamper- Resistant Receptacles in accordance with 406.11 of the 2008 N.E.0 22. In accordance with the Land Development Code, lots shall be sodded before final at least 10 feet around the structure. F.F.E.-Finished Floor Elevation F.B.C-Florida Building Code 5th Edition R.O.W.-Right of Way A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2008) f Unit 35 Column SO. FEET PRICE UNDER ROOF: 1,466 $ 112.65 OTHER: - $ - VALUATION $ 165,144.90 FEE SHEET $ 686.00 ADDRESS $ 40.00 DRIVEWAY $ 40.00 BUILDING: $ 779.72 ELECTRICAL: $ 154.35 PLUMBING: $ 102.90 MECHANICAL: $ 72.03 SUB-TOTAL $ 1,109.00 TOTAL $ 1,109.00 SEWER: $ 2,010.00 WATER: $ 641.00 IRRIGATION: $ - TOTAL: $ 2,651.00 WATER METER: IRRIGATION METER FIRE DEPARTMENT FEES PLANS TOTAL: INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 4,313.35 PARK IMPACT FEES $ 769.56 SIF'S: 100.0% $ - 1.0% $ - TOTAL: $ - T I F'S: $ 3,480.00 99% $ 3,445.20 1% $ 34.80 TOTAL: $ 8,562.91 PASCO COUNTY, FLORIDA Permit No. 9066 Date Permitted Builder Name/Owner Name Control#`~ County Parcel No. ()2-9-2_4_O_,'V0_0oC00_04j5C3 SubDIY: _ zJfit Address/Location t!9 � ,C� 5tvxd oyd`e' Classification/Type of Use AS TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: I`&� Exempt ❑ Yes [] No How Determined Impact Fee Amount Zone No. TAZ: SCHOOL IMPACT FEE Account (056) Single-Family Detached House Amount $ (057) Mobile Home (058) Other Residential 123) Collection Fee Exempt (]Yes ❑No How Determined PARKS AND RECREATION FEE Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation Total Zone TOTAL AMOUNT $ 2 k Ak Exempt ❑ Yes ❑ No How Determined LIBRARY FEE Land Account Land Credit Land Total Facility Account Facility Credit Facility Total Exempt ❑Yes ❑ No How Determined Total Amount RESOURCE FEE ERU TOTAL AMOUNT Prepared By r Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY Acknowiedgement below does not Imply acceptance of concurrence,but simply recelpt of a copy of this form,placing the building permit owner on notice of this assessment and the conditions of payment for same. DATE RECEIVED BY RECEIPT NO. DATE BY t 02-26-21-0300-00000-0350 Pasco County Property Appraiser Page 1 of 1 Data Current as Of: Weekly Archive:- Saturday, October 28, 2017 Parcel ID 02=26-21-0300-00000-0350 (Card: 001 of 001) Classification 00 =Vacant Residential Mailing Address Property Value RYMAN CONSTRUCTION INC Ag Land $0 36413 STATE ROAD 54 Land $15,449 ZEPHYRHILLS FL 33541-2275 Building $0 Physical Address Extra Features $0 6758 BASSWOOD CIR ZEPHYRHILLS, FL 33542 lust Value $15,449 Legal Description (First 4 Lines) Assessed (Non-School Amendment 1) $15,449 See Plat for this Subdivision Taxable Value $15,449 DRIFTWOOD PHASE V PB 62 PG 071 LOT 35 OR 6452 PG 1430 Jurisdiction City of Zephyrhills Land Detail (Card: 001 of 001) Line _ Use Description Zoning Units_ Type T Price_ Condition alue _ 1 - 0100 �SFR �MPUD 1,640.00 SF $8.75-4� 1.00 $14,350 2 I 0100 SFR MPUD 478.00 1 SF $2.30 1.00 i $ 01 99 _ Additional Land Information Acres-I 0.05 Tax Areal� � 30ZH ; Fode X Residential Code i DRIFLPI Building Information - Use 00 - Unimproved (Card: 001 of 001) Unimproved Parcel 00 - Unimproved Extra Features (Card: 001 of 001) _ Line Description �iYea�- r jUnits Value No Extra Features Sales History Previous Owner: N/A Month/Yearr�B-ook/Page i yT pe DOR_ -f Code ConditionlAmount 06/2005 16452 / 1430 Warranty Deed !_ Vacant 1 $0— 07/1 89 1 1142 / 0112 Warranty Deed Vacant $0 Executor's Deed (Personal 01/1981 1105 / 0358 Vacant $0 i Representative's) � http://search.pascopa.com/pareel.aspx?parcel=2126020300000000350 11/2/2017 (IIIII IIIII IIIII IIIII IIIII IIIII IIIII IIIII IIIII IIIII IIII IIII 2017146962 Permit No. Parcel ID No D a-a-(�--t o z,0 0—0o000—0350 NOTICE OF COMMENCEMENT State of . 1 County of '\-*.*.)A SC a THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and In accordance with Chapter 713,Florida Statutes, the following information is provided in this Notice of Commencement: 1. Description of Property: Parcel Identification No. 6a.-a6—a1- 0'3bo 00000-o35 WNfl Street Address: "9 / .+ s 2. General Description of Improvement 1J�� C,OiN)S'1-e� o O'G C7" 1?I- T t � N m aO f9 1910 .+ IF d N N 3. Owner Information or Lessee information if the Lessee contracted for the improvement: 3 0D Nam c� ` 36�{t3 �� 5� GltpilSr���\S V L .omn Address City t— State Interest in Property: w' -%Z "� m99 O 6 Name of Fee Simple Titleholder. A a (If different from Owner listed above) F Address } City State 4. Contractor. V1n0.h ConJ/vtC �b4� e Address City V State Contractor's Telephone No.: 3-7 Go 5. Surety: n Name C3, N v Io Address city State Amount of Bond: $ Telephone No.: t�m 6. Lender. Name :�'-o Address � City Stale 'fvtl++b-D Lenders Telephone No.: 3 c -o 7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)(7),Florida Statutes: ! M � x Name wo Address Ciry State W Y Telephone Number of Designated Person: r .4 . 2) W W LL In W 8. In addition to himself,the owner designates of_ 0 LL S J U to receive a copy of the Lienors Notice as provided in Section 713.13(1)(b),Florida Statutes. 0 Z C F -J Telephone Number of Person or Entity Designated by Owner. O 0 - tY 0- A. (9 !�F- LL! I- W 9. Expiration date of Notice of Commencement(the expiration date may not be before the completion of construction and final payment to the ik W z CO IL p contractor,but will be one year from the date of recording unless a different date is specified): ®'P 0 <J O WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT LL of U U. ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN W U U RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE S RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT = h d LL- WITH Y YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. c) Wr Under penalty of perjury,1 declare that I have read the foregoing notice of commencement and that the facts stated therein are true to the best V 2 OU U " W of my knowledge and belief. Q f- J Q "1 p } U m 0 LL U STATE OF FLORIDA -- LL W Z C) J COUNTY OF PASCO !- Q � Lu lure of Own or ssee,or Owners or Lessee's Authorized O W O Lj-O Q er/Manager LL- UU � � u 0 In C) n Signatory's Title/Office O I-- Z W G / WCoQ - The foregoing instrument was acknowledged bef a me Jlh?I$ J day of 2e � 20 a by k2✓r �-• �J�+ran I- CO = LL, z as �ef/ae, (type of authority,e.g.,officer,trustee,attorney in fact)for Z 1- Q V.l wy //R (name of party o behalf o whom instrument was executed). F' U n m Personally Known®OR Produced Identification❑ Notary Signature Type of Identification Produced Name(Print) "b AN NA MARIE LYNCH TERRY iP Notary PubIIC-State Of Florida °a o 3• Commission•FF 950064 m © e My Comm.Expires Apr 4.202U ya, vhr ''Faun °• Banded through National Notary 4s°• t ` wpdata/bcs/noticecommencement_pc053048 �.r c 3j t~ _a s?, NSMW _ems - 5; as i i g g x i •'`°�F,:ari'4''��5;., ti, t Y�ti4'' `s,d '!-`}3,'-'�''• ,^ �1 a,",w'�. �-.:a-... � �[` pxc O,iY<+s'.:'• ><w".�i"`r�•� ;�.� '�. ?�- ,=.o' t`��p�>s ,S a[+=.�°=' 'O_'/,+,',':.E_:�^.>.:.,- ...�1Q:, �� -',¢ ,: `.^'ice t. - _ '�- -;•�b.,_ _ •�-r,>��.�°:=;'"�. .:ai=�°` - t::e:�.;.��--.� - - - _ :�=�a.,�=rat. �'x?�.j,�..,: ?=�.j•':- �xrrs� _ u.-''..;�:.�„ ':•_�.,� :_�.:._ _ .�� �� '�•x'�« �. - _-'-�-��=�;r suer.-._.. - }'.`Ci:'.*"e^ p-s-�^'.. "� - - - �.+��" r,4 .ir•u�� - v-c?a?�-,t..c�.3':�.r�` �,hr:ti. `-: -;;��' :.y.. _�"��`'.? -c^�•-m. �." _ ...:._�'s`r-." - -^•4 r�•--•o..: ss.;>l:r.�_6�.,�;i _ '^-��3'-'r=`-s ,fir., 'ia �-'�� -wf.�^a.- A 2•: yt•e:-' - .r.;,`.i`� '{K5 M"i'.`'��r.. i`Y-'-�,I i,��� 1 *>_ t9', �F.:,�''-i'� x � 't��yr::�'t-..•,'::i...•.t.,,_.... ��50: �e5e++.••:. ,;-'i<,e�.-.:si ',.�ma-.d $I@s `,.' _ 'i7'=ws t:u._d ".. ' 1 rdFijI,�?-�:eY.r i;,.�.`.�.'�.tI,,T�t -:JMr:,.,w^,t.i(iL��;:a F'^'•�..`sv�-xz_r;- s�•�eia-,•.v..E.�t'�s'"c'aa-_.:'_"-['-s+..�`.:.."-`s'-�".a<�i'e_ �r.-,�",..•a_.Ft r;.;+iaa.t_:"•,.t'ti'�-�c'-c.i''.cF c�:f..�.�,,:.,__.:_a-;�>•�'s'�.•�r�`?�i�,?'"_Yr.4Y2 w.`�,-.+r'�.,���aS-:y;,co.u:,�rx�t.%1i_ •:�"?.�u- --.r:e -- ' _ _ � ' `�� ==a• �'` —RETENTION& LANDSCAPING 00 � �� �=� `�'�;�; :..a�. -�����R E ,®�,: —i E_p�y�R 1LL5�P'�R01 TO• . C L 50.11, .26.89 N 89053132"E _ 77.0d .� - o 3:031 �.. O cn in 21 0 0 o a cn .a -- cn N 89053'32"E 77.00'I i rn N N N Cl y O pp Oo OD o 33 m 32 m 31 o am .�` O N ' N S 22 i y I COOair O E� r: - m a ' 6 m 89°53'32"E 77.09 S 8° 1 " O. 0 O '. �. 2' -�-- E 9 P Ncn 27.50' 27.50' 33.03' _ co ` N 8905332"E 77.00 f 176.03' rn �' ._ cn o 0 CD 24 CD 00 in Nab' - .•f .,...._�.I O 1 1 O is 7.08 `� N 89'53'52"E _ 69.93'. DRAINAGE EASEMENT m Finished Floor r amCA Itl I Elevation=92.70 I M 25 y. Lot 132 - W m•.: I. STI N 89°5332"E 70.1 ' I XI t _ CRI T C LO Ca L`•b"may-'t•'"'`:cwaYE�_'.?;�:.` N p C 4'e;i•s"-i``?±Y v�.s'��,^ N',.:�;i':: ° 11 I C ; N 89 53'32 E 70.30' N� FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Ryman 6 Plex Builder Name: �] 11tUM�JY1 Street: Permit Office: P2'sco City,State,Zip: Dade City,FL, Permit Number: J qO 1 Owner: Ryman 6 Plex. Jurisdiction: `�6'0 Design Location: FL,Tampa COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/doorjambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated, and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or. air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 9/7/2017 7:58 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014' Florida Department of Business and Professional Regulations Residential Whole Building Performance and Prescriptive Methods ADDRESS: Permit Number: Dade City.FL MANDATORY REQUIREMENTS See individual code sections for full details. 401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law [Section 553.9085,Florida Statues]requires the EPL display card to be Included as an addendum to each sales contract for both presold and nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix C. El R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.1 through R402.4.4. 0 R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.The sealing methods between dissimilar materials shall allow for differential expansion and contraction. • R402.4.1.1 Installation.The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table 402.4.1.1,as applicable to the method of construction. Where required by the code official,an approved third party shall inspect all components and verify compliance. • R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 6 air changes per hour in Climate Zones I and 2,and 3 air changes per hour In Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3.Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off,and 6.Supply and return registers,if installed at the time of the test,shall be fully open. 0 R402.4.2 Fireplaces.New wood-burning fireplaces shall have tight-fitting flue dampers and outdoor combustion air. 0 R402.4.3 Fenestration air leakage.Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot(1.5 Uslm2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400 or AAMA/WDMA/CSA 1 01/I.S.21A440 by an accredited,independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. 0 R402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm(0.944 L/s)when tested in accordance with ASTIVI E 283 at a 1.57 psf(75 Pa)pressure differential.All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. El R403.1.1 Thermostat provision(Mandatory).At least one thermostat shall be provided for each separate heating and cooling system. R403.1.3 Heat pump supplementary heat(Mandatory).Heat pumps having supplementary electric-resistance heat shall have controls that,except during defrost,prevent supplemental heat operation'when the heat pump compressor can meet the heating load. R403.2.2 Sealing(Mandatory)%II ducts,air handlers,and filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post-construction or rough-in testing below. Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either an energy rater certified in accordance with Section 553.99,Florida Statutes,or as authorized by Florida Statutes,to be"substantially leak free"by either of the following: 1. Post-construction test:Total leakage shall be legs than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(26 Pa)across the entire system,including the manufacturer's air handier enclosure.All register boots shall be taped or otherwise sealed during the test. 2. Rough-in test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(26Pa)across the system,including the manufacturer's air handler enclosure.All registers shall be taped or otherwise sealed during the test.If the air handler Is not installed at the time of the test,total leakage shall be less than or equal to 3 cfm (85 Umin)per 100 square feet(9.29 m2)of conditioned floor area. Exceptions: 1. The total leakage test is not required for ducts and air handlers located entirely within the building envelope. 2. Duct testing is not mandatory for buildings complying by Section R405 of this code. 9/7/2017 7:61 AM EnergyGaugeO USA-FlaRes2014 -Section k405.4.1 Com Page 1of3 FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) • R403.2.3 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. • R403.3 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C) or below 55*F(1 3*C)shall be insulated to a minimum of R-3., R403.3.1 Protection of piping Insulation. • R 403.4.1 Circulating hot water systems(Mandatory). Circulating hot water systems shall be provided with an automatic or readily accessible manual switch that can turn off the hot-water circulating pump when the system is not in use. 11 R403.4.3 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3 1/2 inches(89 mm)in the hot water distribution line and cold water line located as close as possible to the storage tank. 0 R403.4.4 Water heater efficiencies(Mandatory). 0 R403.4.4.1 Storage water heater temperature controls R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature setting range shall be from 100°F to 140°F(38°C to 60'C). R403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s) of combustion types of service water heating systems to be turned off. 0 R403.4.4.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1. R403.4.4.2.1 Solar water heating systems.Solar systems for domestic hot water production are rated by the annual solar energy factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors, and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol,Collectors in installed solar water heating systems should meet the following criteria: 1. Be installed with atilt angle between 10 degrees and 40 degrees of the horizontal-,and 2. Be installed at an orientation within 45 degrees of true south. ❑ R403.6 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code,Residential or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. El R403.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment. 0 R403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1.This code does not allow designer safety factors.*provisions for future expansion or other factors which affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. • R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load,but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.6,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load. 9/7/2017 7:51 AM EnergyGauge@ USA-FIaRes2014 -Section R405.4.1 Com Page 2 of 3 FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) 0 R403.6.1.1 Cooling equipment capacity.(continued) The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacture's expanded performance data shall be used to select cooling-only equipment.This selection shall be,used to select cooling-only equipment.This selection shall be based on the outdoor design dry bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower cfirn provided by the expanded performance data, the design value for entering wet bulb temperature and the design value for entering dry bulb temperature. Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space. Exceptions: 1. Attached single-and multi-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. - When signed and sealed by a Florida-registered engineer,in attached single-.and multi-family units,the capacity of equipment may be sized in accordance with good design practice. 0 R403.6.1.2 Heating equipment capacity R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section R403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load. R403.6.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.6.1. R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.6.1. 0 R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. ❑ R403.7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the Commercial Provisions in lieu of Section R403. ❑ R403.8 Snow melt system controls(Mandatory). Snow and Ice-melting systems,supplied through energy service to the building,shall include automatic controls capable of shutting off the system when the pavement temperature is above 55°F,and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F. ❑ R403.9 Swimming pools,inground spas and portable spas(Mandatory). The energy requirements for residential pools and inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSIIAPSP-1 5.The energy requirements for portable spas shall be in accordance with ANSI/APSP-14. 0 R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on-off switch that is mounted outside the heater to allow shutting off the heater without adjusting the thermostat setting. R403.9.1.1 Gas and oil-fired pool and spa heaters. All gas-and oil-fired pool and space heaters shall have a minimum thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013 when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights. R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. 0 R403.9.2 Time switches. Time switches or other control method that can automatically turn off and on heaters and pumps according to a preset schedule shall be installed on all heaters and pumps.Heaters,pumps and motors that have built in timers shall be deemed in compliance with this equipment. Exceptions: • 1. Where public health standards require 24-hour pump operations. 2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation. 0 R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Outdoor pools deriving over 70 percent of the energy for heating from site-recovered energy,such as a heat pump or solar energy source computed over an operating season. ❑ RR404.1 Lighting equipment(Mandatory). A minimum of 75 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps. Exception; Low-voltage lighting shall not be required to utilize high-efficacy lamps. 0 R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights ❑ R405.2 Performance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R-6. 0 R405.2.1 Performance ONLY. Ceilings shall have minimum insulation of R-19.Where single assemby of the exposed deck and beam type or concrete deck roofs do not have sufficent space,R-1 0 is allowed. 9/7/2017 7:51 AM EnergyGauge@ USA-FlaRes2014 -Section R405.4.1 Corn Page 3 of 3 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED-ENERGY PERFORMANCE INDEX* = 98 The lower the EnergyPerformance Index,the more efficient the home. Dade City, FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Multi-family a.Concrete Block-Int Insul,Exterior R=5.0 3114.00 ft2 b.Frame-Wood,Adjacent. R=1 1.0 1512.00 ft2 3. Number of units,if multiple family I c.N/A R= ft2 4. Number of Bedrooms 12 d.NIA R= ft2 5. Is this a worst case? No 10.Ceiling Types Insulation Area a.Under Attic(Vented) R=30.0 6576.00 ft2 6. Conditioned floor area(ft2) 6576 b.N/A R= ft2 7. Windows" Description Area c.N/A R= ft2 a. U-Factor: Dbl,U=0.30 522.00 112 11.Ducts R ft2 SHGC: SHGC=0.26 a.Sup:Attic,Ret:Attic,AH:Garage 6 200 b. U-Factor* N/A ft2 SHGC: 12.Cooling systems kBtu/hr Efficiency c. U-Factor. N/A ft2 a.Central Unit 106.2 SEER:14.00 SHGC: d. U-Factor. N/A ft2 SHGC: 13.Heating systems kBtuihr Efficiency Area Weighted Average Overhang Depth: 11000 ft. a.Electric Strip Heat 106.2 COP:1.00 Area Weighted Average SHGC: 0.260- 8. Floor Types Insulation Area 14.Hot water systems a.Slab-On-Grade Edge Insulation R=0.0 6576.00 ft2 a.Electric Cap:40 gallons EF:0.95 b.N/A R=' ft2 b. Conservation features c.N/A R= ft2 None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building ES Construction through the above energy saving features which will be installed(or exceeded) 0 4P 0 in this home before final inspection. Otherwise,a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Date: Address of New Home: City/FL Zip: D Wr, *Note: This is not a Building Energy Rating. If your Index is below 70,your home may qualify for energy efficient mortgage(EEM)incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation,-contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 9/7/2017 7:50 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Ryman 6 Plex Builder Name: Street: Permit Office: Pasco City,State,Zip: Dade City,FL, Permit Number: Owner: Ryman 6 Plex Jurisdiction: Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2} 1. New construction or existing New(From Plans) 9. Wall Types(4626.0 sqft.) Insulation Area 2. Single family or multiple family Multi-family a.Concrete Block-Int Insul,Exterior R=5.0 3114.00 ft2 b.Frame-Wood,Adjacent R=11.0 1512.00 ft2 3. Number of units,if multiple family 1 c.NIA R= ft2 4. Number of Bedrooms 12 d.N/A R= ft2 10.Ceiling Types (6576.0 sqft.) Insulation Area 5. !s this a worst case? No a.Under Attic(Vented) R=30.0 6576.00 ft2 6. Conditioned floor area above grade(ft2) 6576 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(522.0 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Garage 6 200 a. U-Factor: Dbl,U=0.30 522.00 ft2 SHGC: SHGC=0.26 b. U-Factor: N/A ft2 12.Cooling systems kBtu/hr Efficiency SHGC: a.Central Unit 106.2 SEER:14.00 c. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: NIA ft2 a.Electric Strip Heat 106.2 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 1.000 ft. Area Weighted Average SHGC: 0.260 14.Hot water systems 8. Floor Types (6576.0 sqft.) Insulation Area a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 6576.00 ft2 EF:0.950 g b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.079 Total Proposed Modified Loads: 166.75 PASS I Total Baseline Loads: 170.26 i I hereby certify that the p, .s..,,and pecifications covered by Review of the plans and a21141 S ;q� ifh the Florida Energy specifications covered by this ,q�' '" Q this calculation are in comp,ja Code. f� � calculation indicates compliance r,,Y rrr, �` ._-,.�,a° I with the Florida Energy Code. ti �n,,, ' __ •°'�=''`„ O PREPARED BY: Before construction is completedtA DATE: this building will be inspected for compliance with Section 553.908 * ,� I hereby certify that this building,as designed,is in compliance Florida Statutes. with the Florida Energy Code. Q'OD WE V OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory-sealed In accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist In accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house. 9/7/2017 7:49 AM EnergyGauge@ USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 FORM R405-2014 PROJECT Title: Ryman 6 Plex Bedrooms: 12 Address Type: Street Address Building Type: User Conditioned Area: 65i6 Lot# Owner: Ryman 6 Plex Total Stories: 1 Block/Sub Division: #of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: Permit Office: Pasco Cross Ventilation: No County: Pasco Jurisdiction: Whole House Fan: No City,State,Zip: Dade City, Family Type: Multi-family FL, New/Existing: New(From Plans) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMIY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Tampa FL—TAMPA—INTERNATI 2 39 91 70 75 645.5 54 Medium BLOCKS Number Name Area Volume Blockl 6576 52608 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated I Main 6576 .52608 Yes 12 12 1 Yes Yes Yes FLOORS Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio Main 346 ft 0 6576 ft2 ---- 0 0 1 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) I Hip Composition shingles 6930 ft2 0 ft2 Medium 0.9 N 0.9 No 0 18.4 ATTIC # Type Ventilation Vent Ratio(I in) Area RBS IRCC I Full attic Vented 300 6576 ft2 Y N CEILING Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type I Under Attic(Vented) Main 30 Blown 6576 ft2 0A Wood 91712017 7:49 AM EnergyGauge@ USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 4 . ' . ^ 9/7o0 7r4nmm EnomvGauoe@VSx pJaRoozo1v Section n4us.4.1 Compliant ouAnam Page 3of4 FORM R405-2014 HOT WATER SYSTEM V # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 40 gal 150 gal 120 deg None SOLAR HOT WATER SYSTEM V FSEC Collector Storage Carl # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS Supply Return Air CFM 25 CFM25 HVAC# # Location R-Value Area Location Area Leakage Type Handier TOT OUT QN RLF Heat Cool 1 Attic 6 200 ft2 Attic 100 ft2 Prop.Leak Free Garage cfm 197.3 cfm 0.03 0.50 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Cooling n Feb H Me I JA ay Jun Jul Aug Sep Oct NovD Heating Jan Feb X Mar Apr' May Jun Jul Aug Sep Oct NovV Dec Venting Jan Ifeb Mar X Apr may rl Jun ri Jul ri Aug ri Sep 1XI Oct HX Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 9f7l20 17 7.49 AM EnergyGauge@ USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 4 Job: Ryman 6 Plex 4+ wrightsoft- Projecl Summary Date: Sep 06,2017 Unit 1 By: DJM Proiect Information For: Ryman 6 Plex Dade City, FL Notes: Desicin Information Weather: Tampa Intl AP,FL, US Winter Design Conditions Summer Design Conditions Outside db 43 OF Outside db 91 OF Inside db 70 OF Inside db 75 OF Design TD 27 OF Design TD 16 OF Daily range L Relative humidity 60 % Moisture difference 54 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 10083 Btuh Structure 10451 Btuh Ducts 2317 Btuh. Ducts 3367 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (gone) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 12400 Btuh Use manufacturer's data n Rate/swingmultiplier 0.96 Infiltration Equipmerlsensi le load 13321 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2570 Btuh Ducts 767 Btuh Central vent(0 cfm) 0 Btuh Heating? Cooling (gone) Area(11:2) 110 11 Equipment latent load 3337 Btuh Volume(ft3) 9693 9693 Air changes/hour 0.43 0.23 Equipment Total Load(Sen+Lat) 16658 Btuh Equiv.AVF(cfm) 70 37 Req.total capacity at 0.80 SHR 1.4 ton Heating Equipment Summary Cooling Equipment Summary Make Make Carrier Trade 5 KW Trade CARRIER AIR CONDITIONING Model Cond 24ACB318ABN32 AHRI ref Coil FB4CNP018L AHRI ref 9859025 Efficiency 100 EFF Efficiency 11.5 EER, 14 SEER Heating input 3.6 kW Sensible cooling 13680 Btuh Heating output 12409 Btuh Latent cooling 3420 Btuh Temperature rise 20 OF Total cooling 17100 Btuh Actual air flow 570 cfm Actual air flow 570 cfm Air flow factor 0.046 cfm/Btuh Air flow factor 0.041 cfm/Btuh Static pressure 0.53 in H2O Static pressure 0.53 In H2O Space thermostat Load sensible heat ratio 0.81 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. virightsoft, 2017-Sep-07 011:16:111 Right-Suite®Universal 2017 17.0.23 RSU 11033 Page 1 AtL51 Google DrivekDocuments%sonny'skRyman 6 Pjex,rup Calc=MA Front Door faces: E Project Summary Job: Ryman 6 Plex -} - wrightsoft" •J Date: MO6,2017 Unit 2 y DJ Project Information, For: Ryman 6 Plex Dade City, FL Notes: Design Information Weather: Tampa Intl AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 43 °F Outside db 91 °F Inside db 70 °F Inside db 75 °F Design TD 27 °F Design TD 16 °F Daily range L Relative humidity 50 % Moisture difference 54 gdlb Heating Summary Sensible Cooling Equipment Load Sizing Structure 6111 Btuh Structure 8327 Btuh Ducts 2331 Btuh Ducts 3390 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 8442 Btuh Use manufacturer's data n Rate/swing multiplier 0.96 Infiltration Equipment sensible load 11295 Btuh. Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 1846 Btuh Ducts 814 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling (none) Area(ftz) 1090 1090 Equipment latent load 2660 Btuh Volume(IP) 9693 9693 Air changes/hour 0.20 0.11 Equipment Total Load(Sen+Lat) 13955 Btuh Equiv.AVF(cfm) 33 18 Req.total capacity at 0.70 SHR 1.3 ton Heating Equipment Summary Cooling Equipment Summary Make Make Carrier Trade 5 KW Trade CARRIER AIR CONDITIONING Model Cond 24ACB31BABN32 AHRI ref Coil FB4CNP018L AHRI ref 9859025 Efficiency 100 EFF Efficiency 11.5 EER, 14 SEER Heating input 2.5 kW Sensible cooling 11970 Btuh Heating output 8448 Btuh Latent cooling 5130 Btuh Temperature rise 13 °F Total cooling 17100 Btuh Actual air flow 570 cfm Actual air flow 570 cfm Air flow factor 0.068 cfm/Btuh Air flow factor 0.049 cfm/Btuh Static pressure 0.53 in H2O Static pressure 0.53 in H2O Space thermostat Load sensible heat ratio 0.81 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. I_�.. 2017-Sep-07 08:16:11 _� • 4 Wrigh tSOft' Right-Suite®Universal2017 17.0.23 RSU11033 Paget ...Google DrivelDocumentslSonny's%Ryman 6 Plex.rup Calc=MJ8 Front Door faces: E wrightsoft-1 Project Summary Job: Ryman 6 Plex Date: Sep 06,201T Unit 3 By: DJM Project Information For: Ryman 6 Plex Dade City, FL Notes: Desicin Information Weather: Tampa Intl AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 43 OF Outside db 91 OF Inside db 70 OF Inside db 75 OF Design TD 27 OF Design TD 16 OF Daily range L Relative humidity 50 % Moisture difference 54 gr1lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 6111 Btuh Structure 8327 Btuh Ducts 2331 Btuh Ducts 3390 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (qone) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 8442 Btuh Use manufacturer's data n Rate/swing multiplier 0.96 Infiltration Equipment sensible load 11295 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 1846 Btuh Ducts 814 Btuh Central vent(0 cfm) 0 Btuh HeatingCooling (gone) Area(ft2) t 109 1012 Equipment latent load 2660 Btuh Volume(fP) . 9693 9693 Air changes/hour 0.20 0.11 Equipment Total Load(Sen+Lat) 13955 Btuh Equiv.AVF(cfm) 33 18 Req.total capacity at 0.70 SHR 1.3 ton Heating Equipment Summary Cooling Equipment Summary Make Make Carrier Trade 5 KW Trade CARRIER AIR CONDITIONING Model Cond 24ACB318ABN32 AHRI ref Coll FB4CNP018L AHRI ref 9859025 Efficiency 100 EFF Efficiency 11.5 EER, 14 SEER Heating input 2.5 kW Sensible cooling 11970 Btuh Heating output 8448 Btuh Latent cooling 5130 Btuh Temperature rise 13 OF Total cooling 17100 Btuh Actual air flow 570 cfm Actual air flow 570 cfm Air flow factor 0.068 cfm/Btuh Air flow factor 0.049 cfm/Btuh Static pressure 0.53 in H2O Static pressure 0.63 in H2O Space thermostat Load sensible heat ratio 0.81 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 14 wrightsoft' Right-SuiteQD Universal 2017 17.0.23 RSUl 1033 2017-Sep-07 08:16:11 AL Google DriveiDocurnentskSonny'slRyman 6 Plex.rup Cato=MJ8 Front Door faces: E Page 3 Project Summary Job: Ryman 6 Plex -} - W ri[ghtsoft" `J Date: Sep 06,2017 Unit 4 By: DJM Proiect Information For: Ryman 6 Plex Dade City, FL Notes: Design Information Weather: Tampa Intl AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 43 OF Outside db 91 OF Inside db 70 OF Inside db 75 OF Design TD 27 OF Design TD 16 OF Daily range L Relative humidity. 50 % Moisture difference 54 gdlb Heating Summary Sensible Cooling Equipment Load Sizing Structure 6111 Btuh Structure 8327 Btuh. Ducts 2331 Btuh Ducts 3390 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 8442 Btuh Use manufacturer's data n Rate/swing multiplier 0.96 Infiltration Equipment sensible load 11295 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 1846 Btuh Ducts 814 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling (none) Area(ft2) 1090 1090 Equipment latent load 2660 Btuh Volume(fF) 9693 9693 Air changes/hour 0.20 0.11 Equipment Total Load(Sen+Lat) 13955 Btuh Equiv.AVF(cfm) 33 18 Req.total capacity at 0.70 SHR 1.3 ton Heating Equipment Summary Cooling Equipment Summary Make Make Carrier Trade 5 KW Trade CARRIER AIR CONDITIONING Model Cond 24ACB31BABN32 AHRI ref Coil FB4CNP018L AHRI ref 9859025 Efficiency 100 EFF Efficiency 11.5 EER, 14 SEER Heating input 2.5 kW Sensible cooling 11970 Btuh Heating output 8448 Btuh Latent cooling 5130 Btuh Temperature rise 13 OF Total cooling 17100 Btuh Actual air flow 570 cfm Actual air flow 570 cfm Air flow factor 0.068 cfm/Btuh Air flow factor 0.049 cfm/Btuh Static pressure 0.53 in H2O Static pressure 0.53 in H2O Space thermostat Load sensible heat ratio 0.81 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2017-Sep-07 08:16:11 W 1Q�trt3ft' Right-Suite®Universal2017 17.0.23 RSU11033 Page 4 ...Google DrivelDocumentslSonny'slRyman 6 Plex.rup Calc=MA Front Door faces: E ' Project Summa Job: Ryman 6 Plex wright irQft' Date: Sep 06,2017 1� Unit 5 By: DJM Proiect Information For: Ryman 6 Plex Dade City, FL Notes: Design Information Weather: Tampa Intl AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 43 °F Outside db 91 °F Inside db 70 °F Inside db 75. °F Design TD 27 °F Design TD 16 °F Daily range L Relative humidity 50 % Moisture difference 54 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 6111 Btuh Structure 8327 Btuh Ducts 2331 Btuh Ducts 3390 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 8442 Btuh Use manufacturer's data n Rate/swing multiplier 0.96 Infiltration Equipment sensible load 11295 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 1846 Btuh Ducts 814 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling (none) Area(ft2) 1090 1090 Equipment latent load 2660 Btuh Volume(ft') 9693 9693 Air changes/h'our 0.20 0.11 Equipment Total Load(Sen+Lat) 13955 Btuh Equiv.AVF(cfm) 33 18 Req.total capacity at 0.70 SHR 1.3 ton Heating Equipment Summary Cooling Equipment Summary Make Make Carrier Trade 5 KW Trade CARRIER AIR CONDITIONING Model Cond 24ACB318ABN32 AHRI ref Coil FB4CNP018L AHRI ref 9859025 Efficiency 100 EFF Efficiency 11.5 EER, 14 SEER Heating input 2.5 kW Sensible cooling 11970 Btuh Heating output 8448 Btuh Latent cooling 5130 Btuh Temperature rise 13 °F Total cooling 17100 Btuh Actual air flow 570 cfm Actual air flow 570 cfm Air flow factor 0.068 cfm/Btuh Air flow factor 0.049 cfm/Btuh Static pressure 0.53 in H2O Static pressure 0.53 in H2O Space thermostat Load sensible heat ratio 0.81 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. i 2017-Sep-07 08:16:11 ,,+ wrllg itSOft` Right-Suite®Universal 2017 17.0.23 RSU11033 Page 'sink ,..Google DrivelDocumentslSonny'slRyman 6 Plex.rup Calc=MJ8 Front Door faces: E Job: Ryman 6 Plex wrightsoft- Pro it 6 oject Summary Da By:te: Sep 06,2017 Un DJM Proiect Info'rmation For: Ryman 6 Plex Dade City, FL Notes: Desicin Information Weather: Tampa Intl AP,FL,US Winter Design Conditions Summer Design Conditions Outside db 43 'F Outside db 91 'F Inside db 70 *F Inside db 75 'F Design TD 27 *F Design TD 16 'F Daily range L Relative humidity 50 % Moisture difference 54 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 10083 Btuh Structure 10451 Btuh Ducts 2317 Btuh Ducts 3367 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (qone) (no Humidification 0 Btuh Blowerne) 0 Btuh Piping 0 Btuh Equipment load 12400 Btuh Use manufacturer's data n Rate/swingmultiplier 0.96 Infiltration Equipmen sensible load 13321 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2570 Btuh Ducts 767 Btuh Central vent(0 cfm) 0 Btuh HeatingCoolm (none) Area(ft2) 110 1108 Equipment latent load 3337 Btuh Volume(fP) 9693 9693 Air changes/hour 0.43 0.23 Equipment Total Load(Sen+Lat) 16658 Btuh Equiv.AVF(cfm) 70 37 Req.total capacity at 0.80 SHR 1.4 ton Heating Equipment Summary Cooling Equipment Summary Make Make Carrier Trade 5 KW Trade CARRIER AIR,CONDITIONING Model Cond 24ACB318ABN32 AHRI ref Coil FB4CNP018L AHRI ref 9859025 Efficiency 100 EFF Efficiency 11.5 EER, 14 SEER Heating input 3.6 kW Sensible cooling 13680 Btuh Heating output 12409 Btuh Latent cooling 3420 Btuh Temperature rise 20 'F Total cooling 17100 Btuh Actual air flow 570 cfm Actual air flow 570 cfm Air flow factor 0.046 cfm/Btuh Air flow factor 0.041 cfm/Btuh Static pressure 0.53 in H2O Static pressure 0.53 in H2O Space thermostat Load sensible heat ratio 0.81 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2017-Sep-07 08:16:11 WrlglliltSOft' Right-Suitee Universal 201717.0.23 RSU1 1033 Page 5 tk GoogleDf.ivplDocumentskSonny'stRyman6PIex.rup Calc=MJ8 Front Door faces: E N "•..un r•..r.T'.:�,,r:,'�:{+,��:�+��!iii''!'1r w� 'r:v �y !>`� r 1 a.. �»V.L�e.w'7bt'YR 'r'�'�I' f!,.,I.I..r r•. I:I r '.',',�:' w.f::q;. seyM Ku 11{:III r....rl.,: .'•n ; .I,ri441p�„I,; .. :.;',e�y'•�'++Fix:.' :li - .:u'il�1:+'::s �., ?E:'1? arl.r ii.`�':, `� iW1 ditrr.o,la.lr;coal r,.t;. _ fti}�e•a 1iy.;': �;, 1: 'Jz� t.I I III 4 ' III. I �r I}1,•I .::,c`�: ', .fi"f`,� 1 .f >M ' dl•,r IL, � t ,•,:fir,. rl,ll , 'Jill',. ,_:.a;:''".::. `�:,•':t'. ...,s5:n.:...,.i:::�.:.:.., i�'j�'::� ,•ir..,,..,,;,r,ra,l a_!tclr{L,,;y.,.,..:...,,. ... 5'.:. ..�.y:.:..�.•...- c".•4.y _ J .ti','kr il..l, ,S to-':'�c•.'oe _ ::� ,. -..,., .I y°:'•r ,.•I..;p ... �i.. :F., mil- # i_.....I 1...I ....14,: -r."? >,•'-: '_::I:`; Pn .jai .,Lk,'�:,sr,ulrlr n ., rr:,ak .I,nr,�,,�!;, _.,,,• .I ...,._..: ,..,,.,;,::^ � r 7�..,. vrn •n�v # !IN4!„ '1 I 41 W's il'' r JI rl r , - r%I yr;I:I.f 'fu.l + r 3 I$ca•rl' v.J II I.I� r ROW r1 •Ot�O _ — v e' 4 - - ,Ir I e• v yLc "il!r is r II I' -•3`.' =� Y ,a — r— 'I"I "II,I 1.1.! Ih�++ff,l I.II� iii4,..qr!,.°^' '.'i:F �.�� nil.® - f�5' °i'" •f ' 1� .Ir^_ al rm�rl,.Il .I;I I1M�nld'.rY '.,1L =.:� /in:,„, •'�`��i` _ ,.0 I e •gy,,fiOjl,!' MI, Ill+r `.� •I(I,I . -; "x;;. 1 r.3, r�;E'r;;• s. �. 'S• �� alri •Iru: ,.I ,Ili �W ulg s:�r, r�,... .I�.r .y �tt.E.:..t c".! ,IVnc,l l It I IrI.l 71 l'41 j;;, 4e •';'; r. I IIrrG, I •x i' II 1 ) 1 I r....I I unm ,.,1E'!1 III I•r ur jf Ali 4:r.bL,'.I:.!:•!..,I.±._,., 11a,,;w::' `:c�:��J:���!Jr' -;jr_=' �, • Lsa+!Y,.tic. � :I'rdli,�li!:I el:Lti,..III I� 1nq,.I u, .41w`I.li':r5".i!i:ii:yi�''I S,7',: �wiiacti IFp� _ -__ _'�> 1f3 �dt"*, '4�•-c�G'%c I!'..I,'..�.•�� _ :i3y,s'"1'i!,a":.;1' - xlY.y IndP i. •n 4 .,r Ie l iiil!'S'lii'jlpl!I'ilq�:a:"'h'i�. ,:{,g,3rc u.. q. ..a i�: �:�%'li.: '.�^w,�,h .•c �,� rl'�I!I, IrIIIIN1fu„yll:�rJ„ �x�:,��;y,r,�'���,•� �'�:::a;i'�.a,.... _ I Job M Ryman 6 Plex Scale: 1 :270 Performed by DJM for: Page 1 Ryman 6 Plex Right-Suite(D Universal 2017 Dade City,FL 17.0.23 RSU11033 2017-Sep-07 08:17:04 ...currents\Sonny'Myman 6 Plex.ru . , ' . . . K���� K� ��K�00��� �� m��o�� Y� Duct Summary �� m�0��n ' — Unit 1 By: oJM Proiect Information For Ryman8Plex Dade City, B Heating Cooling External static pressure 0.53 in H20 0.53 in H2O Proueum|umooa 0 in H2O O in H2O Available static pressure 0.55 in H20 0.53 in H2O Supply/return available pressure 0.336/0.194 in H2O 0.330/0.184 in H20 Lowest friction rate 0.303in/108ft 8.363in/100ft Actual air flow 570 ohn 570 uhn Total effective length(TEL) 146 ft Supply Branch Detail Table. Design Htg Clg Design Diam HxW Duct Actual Ftg.Eqv Name (Btuh) (cfm) (cfm) FR (in) (in) Mail Ln(ft) Ln(ft) Trunk Grille Htg Cig TEL Design Veloc Diam HxW Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FIR (fpm) (in) (in) Opening(in) Mail Trunk Return Trunk Detail Table Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk J. 2017-Sep-0708u6:11 ,�� wmxg�"tSOv� nwm�.�� mm n u ." ouono�onauj 1mm p�a1 a�bk -so"o/ao,ive\o^o"ments\Sonny'skRym""op/e`,"vuu/v~mJopmoouu,mce". s . ' . . . . ��, K���� 00 ��K����� �� �m��m �� =,~ Duct Summary �� S�0��n / - '='— Unit 2 By: ouM Prpject Information For RymonGPlex Dade City, FL Heating Cooling External static pressure 0.53 hnH2O 0.53 hnH2O Pressure losses U in H2O U in H2O Available static pressure 0.53 |nH2O 0.53 in H2O Supply/return available pressure 0390/8.140inH20 0.390/0.140inH20 Lowest friction rate 0.420 in/100ft 0.420 in/100ft Actual air flow 570 uhn 570 uhn ' Total effective length(TEL) 126 ft -Design Htg Clg Design Diam HxW Duct Actual Ftg.Eqv Name (13tuh) (clm) (cfm) FIR (in) (in) Mail Ln(ft) Ln(ft) Trunk Grille Htg Clg TEL Design Veloc Diam HxW Stud/Joist Duct Name Size(in) (cfm) (cfm) N FIR (fpm) (in) (in) Opening(in) Matl Trunk Supp-ly-Branch.Detail Table-, Return Trunk Detail Table Name Type (cfm) (CfM) FIR (fpm) (in) (in) Material Trunk J. zmr�"�o mz1un �� ,r�' wm���n��mc mum�"��um""namnnu�xnou��mm �u 2 . , . . . . ��«� ����k��K� �� n��a�� ��� �W���0��x�V�� Duct —� ---''- Summary Date: Sep o4om7 ^ Unit 3 By: ouM Proiect Information For RymonGPlex Dade City, FL Heating Cooling External static pressure 0.53 in H2O 0.53 in H2O Pmnsuro|osaos O in H2O U in H2O Available static pooaauos 0.53 in H20 0.53 imH2O Supply/return available pressure 0.039/0.181inH20 0.339/0.191 |nH20 Lowest friction rate 0.350 in/100ft 0.359 in/180ft Actual air flow 570 ohn 570 ohn Total effective length(TEL) 148 ft --Supply Branch.Detall-Table Design Htg Cig Design Diam HxW Duct Actual Ftg.Eqv Name (13tuh) (cfm) (cfm) FIR (in) (in) Mafl Ln(ft) Ln(ft) Trunk Re-Whi'MraffOW00tall Table- Grille Htg Cig TEL Design Veloc Diam HxW Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FIR (fpm) (in) (in) Opening(in) Matl Trunk Return Trunk Detail T 6ble, Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk m�r���rmu��� �� .r °°"�htwO"� m��m�um�mmmnn�mmm1m� Page ' ` . ' . , ��, ���� 0M ��8�8��K� �� �m�nM� �� ~~,~ Duct Summary Date: �pn�omr ' — Unit By: oJM Project Irff6tmation- For RymanGP|ax Dade City,FL Heating CamUnQ External static pressure 0.53 in H2O 0.53 in H2O Pressure losses 0 in H2O U inU2O Available static pressure 0.53 in H2O 0.53 in H2O Supply/return available pressure 0.391 /0.138inH20 0391 /0.139inH20 Lowest friction rate 0.410 in/100ft 0.418 in/100ft Actual air flow 570 ofn 570 o8n Total effective length (TEL) 127 ft Name (13tuh) (cfm) (cfm) FIR (in) (in) Mail Ln(ft) Ln(ft) Trunk -Return--Branch-Detail-Table- Grille Htg Clg TEL Design Veloc Diam HxW Stud/Joist Duct Name Size(in) (cfm) (clm) (ft) FIR (fpm) (in) (in) Opening(in) Mafi Trunk Return Trunk Detail Table Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk Design Htg Clg Design Diam HxW Duct Actual Ftg.Eqv ^ cmm�m mom1 -�= w�mght5�nt� mnm-s"itee Universal mnno.2unuu1 1033 Page ^Z5� -o"ogwon°»ooc"rn"maa o"/mnvp°"oPlm.rup calo~*uu Front Door faces: s e, Duct System Summary Job: Ryman 6 Plex �Ittl'���1Saft" Date: Sep 06,2017 Unit 5 By: DJM For: Ryman 6 Plex Dade City, FL Heating Cooling External static pressure 0.53 in H2O 0.53 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.53 in H2O 0.53 in H2O Supply/return available pressure 0.391 /0.139 in H2O 0.391 /0.139 in H2O Lowest friction rate 0.416 in/100ft 0.416 in/100ft Actual air flow 570 cfm 570 cfm Total effective length(TEL) 127 ft Upply Branch.Detail Table.:: Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FIR (in) (in) Mall Ln(ft) Ln (ft) Trunk Unit 5 Bath 1 c 143 5 7 0.489 4.0 Ox 0 VIFx 10.0 70.0 Unit 5 Bath 2 h 462 31 20 0.522 4.0 Ox 0 VIFx 5.0 70.0 Unit 5 Bed 1 h 2259 153 120 0.432 7.0 Ox 0 VIFx 20.6 70.0 Unit 5 Bed 2 h 2238 151 105 0.416 7.0 Ox 0 VIFx 24.0 70.0 Unit 5 Kitchen c 2010 11 98 0.481 6.0 Ox 0 VIFx 11.4 70.0 Unit 5 Living C 2263 110 110 0.508 6.0 Ox 0 VIFx 7.1 70.0 Unit 5 Living-A c 2263 110 110 0.485 6.0 Ox 0 VIFx 10.6 70.0 TableReturn Branch Detail Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FIR (fpm) (in) (in) Opening(in) Matl Trunk rb6 Ox 0 570 570 33.3 0.41.6 533 14.0 Ox 0 VIFx rst43 Table,Return Trunk Detail i Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (Cfm) (cfm) FIR (fpm) (in) (in) Material Trunk rst43 Peak AVF 570 570 0.416 533 14.0 0 x 0 VinlFlx i i I I �:- wPighi3l Right-Suite®Universa12017 17.0.23 RSU11033 2017-Sep-07 08:16:11 ^^` Page 5 } ...Google DrivelDocumenlsksonny'slRyman 6 Plex.rup Cale=MJ8 Front Door faces: E Duct System Summary Job: Ryman 6 Plex 4j.+ wrightsoft, Date: Sep 06,2017 Unit 6 By: DJM F- Project Information For: Ryman 6 Plex Dade City, FL Heating Cooling External static pressure 0.53 in H2O 0.53 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.53 in H2O 0.53 in H2O Supply/return available pressure 0.392/0.138 in H2O 0.392/0.138 in H2O Lowest friction rate 0.415 in/10011 0.415 in/100ft Actual air flow 570 cfm 570 cfm Total effective length(TEL) 128 ft ` ..Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (Cfm) (cfm) FIR (in) (in) Matt Ln(ft) Ln(ft) Trunk Unit 6 Bath 1 C 134 3 6 0.489 4.0 OX 0 VIFX 10.0 70.0 Unit 6 Bath 2 h 412 19 16 0.522 4.0 Ox 0 VIFx 5.0 70.0 Unit 6 Bed 1 c 2319 92 96 0.433 6.0 Ox 0 VIFX 20.4 70.0 Unit 6 Bed 2 h 3580 165 110 0.415 8.0 Ox 0 VIFx 24.4 70.0 unit 6 Kitchen C 2321 57 96 0.477 6.0 Ox 0 VIFX 12.0 70.0 unit 6 Living c 3000 117 124 0.502 7.0 Ox 0 VIFX 8.1 70.0 Unit 6 Living-A C 3000 117 124 0.477 7.0 Ox 0 VIFx 12.0 70.0 Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FIR (fpm) (in) (in) Opening(in) Matl Trunk rb7 Ox 0 570 570 33.3 0.415 533 14.0 Ox 0 VIFx rst48 TableReturn Trunk Detail Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk rst48 Peak AVF 570 570 0.415 533 14.0 0 x 0 VinlFlx 2017-Sep-07 08:16:11 ,," WrlghtSiitl:t' Right-Suite®Universal 2017 17.0.23 RSU11033 .1 .11 �N ...Google DrivelDocumenlsisonny'Myman 6 Plex.rup Cale=WEI Front Door faces: E ° PASCO COUNTY AS gDEVELOPMENT SERVICES PLO , 8731 Citizens Drive Date: 12/20/2018 --COUNT- Y. PLORIDA' New Port Richey, FL 34654 OPEN SPAMS.[NifKNT PLACES: 727-847-2411 Receipt#: 1817919 FEE DESCRIPTION ACCOUNT CODE UNITS INVOICE# FEE AMOUNT PAID RECEIPT# DATE Impact Fee Residential Solid. 24503100-329010 1.00 1413112 $1.5.6 $1.56 1817919 12/20/18 Waste Condo; Multi-Family MH in Park,per Unit 0226210300000000350. TOTALS: $1.56 $1.66 Receipt# Paid By Check# CC Auth# Cashier ID Workstation Receipt Date Amt Paid 1817919 Cash 534 BCCCP15W 12/20/2018 $1.56 Total Payments: $1.56 Pavor ddres Phone RYMAN CONSTRUCTION P#1900 ZHL 58 BASSWOOD CR. 0226210300000000350 Comments: 0226210300000000350 While you will be paying your bill with Pasco County Development Services,the full amount of the credit card or a-check fees,NOT shown above,Is collected by First Billing payment services. 12/20/2018 Page 1 of 1 MyReports/reports//PASCOPROD/PASCO/ReceiptPOS_V6.rpt