Loading...
HomeMy WebLinkAbout18-19461 CITY OF ZEPHYR HILLS 5335-8TH STREET (813)780-0020 1,9461 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL PERMIT INFORMATION LOCATION INFORMATION Permit#:19461 Issued: 3/26/2018 Address: 6526 WAGON TRAIL ST Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 347,525.25 Total Fees: 11,759.19 Subdivision: SILVERADO Amount Paid: 11,759.19 Date Paid: 3/26/2018 Parcel Number: 05-26-21-0080-00600-0150 CONTRACTOR INFORMATION OWNER INFORMATION Name: DR HORTON INC Name: D R HORTON INC Addr: 12602 TELECOM DR Address: 12602 TELCOM DR TAMPA, FL. 33637 TEMPLE TERRACE FL 33637-0935 Phone: Lic: Phone: 813-549-1968 Work Desc: CONSTRUCT SINGLE FAMILY 3,085 SQ FT APPLICATION FEES BUILDING FEE 1,336.64 ELECTRICAL FEE 277.20 PLUMBING FEE 184.80 MECHANICAL FEE 129.36 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5%. 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE-sfr/100% 4,828.00 SCHOOL IMPACT FEE-sfr/1% 48.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32 CW � c Inspections Required FOOTER 2ND ROUGH PLUMB MISC INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications and Must Accompany Application. All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRACTORS SIGNATURE PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: 1� Date Received: Site: -TkAtt' v 1 Permit Type: lslinql� 6OASg Approved w/no comments:❑ Approved w/the below comments: tlY Denied w/the below comments: ❑ This comment sheet shall be ept with the permit and/or plans. Kalvin Swi —Plans Examiner Date Contractor and/or Homeowner (Required when comments are present) PASCO COUNTY C DEVELOPMENT SERVICES PAS 8731 Citizens Drive Date:6/1312018 COUNTY FLORIDA New Port Richey'-FU34654 01,FN sr.vms.VINANT pmcy-s. 727-847-24 1 i NOT A PERMIT Receipt* -1767571 FEE DESCRIPTION ACCOUNT CODE UNITS INVOICE# FEE AMOUNT PAID RECEIPT# DATE Impact Fee Residential Solid 24503100-329010 34.48 1353809 $34.48 $34.48 1767671 6/13/18 Waste Single Family TOTALS: $34.48 $34.48 Receipt# Paid By Check# CC Auth# Cashier ID Workstation Receipt Date Amt Paid 1767571 Check 0759946 540 13CCCP06W 06/13/2018 $34.48 Total Payments: $34.48 Pa or Address Phone D R Horton 1341 Horton Circle Arlington TX 76011 Comments: City of Zephyrhills Solid Was fe�,Perrr it 19461 Address:6626 Wagon T 'is . gon Trains eat Parcel:05-26-21-0080-00600 0150 While ybu will be paying your bill with Pasco Cou;�Oevetbp -.,t Services,the full amount of the credit card or e-check fees,NOT shown above,Is collected by First Billing payment services. MyReports/reports//PASCOPROD/PASCO/RecelptpOS—V6.rpt 6/13/2018 Page 1 of 1 S- 11111 oil 1111111mil Hill 11111 MINOR 2018043934' Rcpt: 1940179 Rec: 10.00 DS: 0.00 IT: 0.00 03/1512018 eRecording Permit No. Parcel ID No.(5'5 ?—(o NOTICE OF COMMENCEMENT State.of County of_ &-��Lo THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 713,Florida Statutes, the following information is provided in this Notice of Commencement 1 Description of Property: Parcel ldentificatlonNo.u+- 1-s Street Address: (657-fn WML-4 grull 2. General Description of Improvement fe-, rc�z-M t, j-e-�,,d e 4 3. Owner Information or Lessee information if the Lessee contracted for the improvement: • 1lC1—jL'0 A Nainje 0(D2 -e -D r -rn LAA-j9 c J 3r3 7 Address city State Interest in Property: Pee rq I-e- Name of Fee Simple Titleholder (if different from Owner listed above) Address Hor city state 4. Contractor. ,me U601 ::Cal Address City— State Contractor's Telephone No.: 5. Surety: A)/-a Name' Address city State Amount of Bond: $—.(-/r Telephone No.: 6. L6nder. A) Name Address city State Lenders Telephone No.: 7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)(7),Florida Statutes: Lo izi'd r-7ud-e- Name �Q Ito e-,n jq� 2 C AaClress itv State Telephone Number of Designated Person: 0 8. In addition to himself,the owner designates of .to receive a copy of the Uenors Notice as provided in Section 713.13(1)(b),Florida Statutes. Telephone Number of Person or Entity Designated by Owner: 9. Expiration date of Notice of Commencement(the expiration date may not be before the completion of construction and final payment to the contractor,but will be one year from the date of recording unless a different date is specified): WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER-THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalty of perjury,I declare that I have read the foregoing notice of commencement and that the facts stated therein are true to the best of my knowledge and belief. STATE OF FLORIDA OT COUNTY OF PASCO Itu Signal e nfowner or Lessee,or Owners or Lessee's Authorized r,OfficPtirectnr/Partner/Manager SSf �p Z-',l - -D-7 Signatory's TftlelOffice The foregoing instrument was acknowledged before me this J��day of Aar81 ,20 L�7by Ml?j�4(a V1 -fiy (type of authority,\-j rity,e.g.,officer,trustee,attorney in fact)for 0 r 40 n (name of a on eha of whom i7, rument was executed). [j Personally Known j OR Produced Identification C] Notary Signature 11P 04L Type of identification Produced Name(Print) 61 PAULA S.OINEIL,Ph.D.PASCO CLERK&COMPTROLLER 03/15/2016 04:24 PH I Of I Notary Pubile State of Florida Michelle Moyes OR wK9693 PG 1027 pirp- My Commission GG'057321 Z -0 Expims itn2�t Vvrpdata/bcs ,1bt'=cd, en ern DR Horton-6526 Wagon Trail St-3,085 sq ft- Column SQ. FEET PRICE MAIN OR LIVING: 3,085 $ 112.65 OTHER AREA UNDER ROOF: - $ - OTHER: - $ - VALUATION $ 347,525.25 FEE SHEET $ 1,232.00 ADDRESS $ 40.00 DRIVEWAY1 $ 40.00 BUILDING: $ 1,336.64 ELECTRICAL: $ 277.20 PLUMBING: $ 184.80 MECHANICAL: $ 129.36 SUB-TOTAL $ 1,928.00 TOTAL $ 1,928.00 SEWER: WATER: IRRIGATION: $ - TOTAL: $ - WATER METER: IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: $ - INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ ' 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 2,481.35 PARK IMPACT FEES $ 769.56 SIF'S: $ 4,828.00 100.0% $ 4,828.00 1.0% $ 48.28 TOTAL: $ 4,876.28 T I F'S: $ 39632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 11,759.19 D.R. Horton-6526 Wagon Trail.St-3085 sq ft Column Es SQ. FEET PRICE MAIN OR LIVING: 3,085 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 347,525.25 FEE SHEET $ 1,232.00 ADDRESS $ 40.00 DRIVEWAY $ 40.00 BUILDING: $ 1,336.64 ELECTRICAL: $ 277.20 PLUMBING: $ 184.80 MECHANICAL: $ 129.36 SUB-TOTAL $ 1,928.00 TOTAL $ 1,928.00 SEWER: $ 2,010. 0 WATER: $ 64100 IRRIGATION: $ - TOTAL: $ 2, 1.00 WATER METER:1 $ 473. IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 5,606.13 PARK IMPACT FEES $ 769.56 SIF'S: $ 4,828.00 100.0% $ 4,828.00 1.0% $ 48.28 TOTAL: $ 4,876.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 14,883.97 Single Family Dwelling Plan Review Comments: L F.F.E. shall lie_ am inimum of.8''_above-'the road.elevation:and an engineered site plan. 2.. Lots shall be graded to.comply with R401.3 of the F.B:.C: 3.: .Compaction test required_.if 24" or more of fill dirt is brought in at any one place: 4. :Tie in survey required:before pouring concrete. .. .. 5. Driveways:require a R.O.W. use permit All 4 sides of driveway thni the sidewalk shall have :expansion matenal:. 6.. All setbacks shall be'met... . .-T.: All.property markers shall be uncovered.and marked.at time of first 'inspection: 8.. :All A.D.A.requirements.shall be met. . 9. No:electric,plumbing, mechanical,,or framing shall be.covered without an;inspection and approval first. = 10.All Garages shall:comply:.with,section R302;6:of the F.B.C.-(Fire-Separation).. 11:Appliances_:shall not:be installed in a location where subj ect to.mechanical'damage unless. :. . -protected--by approved_barriers: M303..4 of the F.B.0 12. Water heaters shall comply.with sect ion P607.3 of the F.B.C: 13.Foundation supports for A/C.units shall be raised at least 3'.' above finished grade, M1308.1. l4. Return air in all.:bedroorris..F.B.C: M1620.4 15. Smoke detectors are to be installed-in accordance:with:R313-.l-of the:F.B.C. 16. All glazing requirements are:.to be in accordance with R308.4.of the F.B.-C. 17. All means,of egress are to:be in accordance with R311.of the F;B.C. :: . I8. `.`Green gypsu' m board"shall riot be used:' a backer iri:showers or tubs. R702:4:2.F.B.C. . . 19..Combination-type A.FCI breakers.are.required:at all.locations requiring an AFCI.type breaker: ; 20. Carbon monoxide alarms-will be required in.'new construction that-uses fossil-burning-heating or appliances or an attached garage.. They shall be,installed in accordance with,the F.B.C.. 21. All plumbing,mechanical,:and.electrical shall-be separate from unit to.unit: This includes all. .' undergrotirid plumbing acid electric: 22.- All 2008:ME:C-. Codes:will.be enforced. 23.Tamper-Resistant Receptacles in accordance with 406.11 ofthe 2008 N.E.0 24.:In accordance:.with the Land:Development:Code- lots shall be.sodded'before final at least 10 feet:around-the.structure: 25'A.cony of the energy cacls shall be with hermit at all times 26 Copy of rival insulation repbrt shall be.nrovided with.hermit befoie.flnaL F.F.E.-Finished Floor Elevation F.B.0 Florida Building Code 5t'Edition R-O.W:-Right of Way. A.D:A:-Americans with Disabilities Act N.E.C.-National Electric Code(2008): 05-26-21-0080-00600-0150 Pasco County Property Appraiser Page 1 of 1 Data Current as Of: Weekly Archive - Saturday, March 17, 2018 Parcel ID 05-26-21-0080-00600-0150 (Card: 001 of 001) Classification 00 - Vacant Residential Mailing Address Property Value D R HORTON INC Ag Land $0 12602 TELECOM DR Land $2,764 TEMPLE TERRACE FL 33637-0935 Building $0 Physical Address Extra Features $0 6526 WAGON TRAIL STREET ZEPHYRHILLS, FL 33541 Just Value $2,764 Legal Description (First 4 Lines) Assessed (Non-School Amendment 1) $2,764 SILVERADO RANCH SUBDIVISION PHASES 6, 8 &9A PB 75 PG 075 BLOCK 6 Taxable Value $2,764 LOT 15 Jurisdiction City of Zephyrhills _ Land Detail (Card: 001 of 001)_ Line Use Description Zoning (Units Type 1Price TConditi-o_n `Value 1 0100 SFR MPUD 6,000.00 SF j $0.40 1.00 $2,400 2 0100 SFR MPUD 1,455.00 SF ; $0.25 1.00 $364 Additional Land Information E de -- Acres 0.17 Tax Area 30SI Code ! Residential Code I SLVRCPI Building Information - Use 00 - Unimproved (Card: 001 of 001) Unimproved Parcel 00 - Unimproved Extra Features (Card: 001 of 001) Line (Description (Year Units IValue No Extra Features Sales History - See All 6 sales Previous Owner: DUNE FL LAND I SUB LLC Month/Year Book/Page _ Type —�~ DOR Code Condition Amount 03/2018 9690 / 1274 Warranty Deed 05 Vacant Multi-Parcel Sale 05/2017 9535 / 0546 _ Certificate of Title 05 Vacant Multi-Parcel Sale 11/2016 9462 / 0384 Mineral Rights or Royalty Transfer 05 Vacant Multi-Parcel Sale http:,Hsearch.pascopa.com/parcel.aspx?parcel=2126050080006000150 3/20/2018 813-780-0020 City of Zephyrhilis Permit Application Fax at3-7ao oo2t Building Department Date Recelded phone Contact for Permitting -- -I-r'r-r-I-rr:r- •r ' Owner's Name Owner Phone Numbers Owner's Address «� T '!'� �`� "`�r' �'' �'� � .�.G)wner Phone Number Fee Simple Titleholder Name r �_ - Owner Phone Number FeeSimple Titleholder Address JOB ADDRESS "OW iVIincl-rVi I I 1-- 3394 1 LOT# .SUBDIVISION ✓ t e-�'� �� PARCEL iD# ��� /�� u�r "� (OBTAINED FROM PROPERTY TAX NOTICE) ' WORK PROPOSED NEW CONSTR 8 ADD/ALT SIGN 0 DEMOLISH- 'INSTALL_ • REPAIR PROPOSED USE F-9 -- SFR COMM OTHER TYPE OF CONSTRUCTION . �� BLOCK FRAME STEEL DESCRIPTION OF WORK �i j�f?J`c�C �:+ 5 t�,}G c� BUILDING SIZE �_- -1 SQ FOOTAGE HEIGHT �`-r-v-I-R-v-o-1_tt-'a e-7^4-9- =BUILDING VALUATION OF TOTAL CONSTRUCTION =ELECTRICAL AMP SERVICE PROGRESS ENERGY 0 W.R.E.C, =PLUMBING $ =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION lot OGAS ROOFING SPECIALTY ] OTHER FINISHED FLOOR ELEVATIONS F FLOOD ZONE AREA =YES NO .-iF-4-6-'i--�'-1-�-7--I-F-i•-i-0-•F-i-i-F-f-B--I--1-9-C-�9--F-�i-B-F-•0-•,'�-P-v--i--@-a-;��w—}--F-v�-1-8�'8-6`-=m�c�8=�1-1�° 9.-8�@-ice`--i"'S--I-R--i- BUILDER / -� . COMPANY - � C:) SIGNATURE REGISTERED Y i N FEE CURREN Y i N Address / t7v x License# Gt�a� Q Cu I ..ELECTRICIAN _, f'',.r COMPANY �a,"1?G�o ,iAFTC.-i" SIGNATURE REGISTERED Y/ N FEECURREN Y/N Address a�+ 'P0� ' r :!� License# { � PLUMBER COMPANY !°' /J~� r` � ��° 141•A .SIGNATURE r REGISTERED Y/ N FEE CURREN Y1/N,/ Address �� F mrl / `A'�•- License# �a4 d G�' MECHANICAL COMPANY &/-,f��:r'f �f„3� d1 lq 4`� SIGNATURE f 1 "'"ram ---REGISTERED Y// N_J FEE CURREN Y/N Address J7,`� �,r,�,r^ , xd fi1�a a�{ .tr�,L`� �c f License# I C/Ic_ OTHER _--^% - -^� COMPANY „` of-),f t •101(07` SIGNATURE ' / . 't � �/ REGISTERED Y j N F FEE CURREN Y/N Address f a -. rf t� t '7 License# RESIDENTIAL Attach(2) Plot Plans; (2)sets of Building Plans; (1)set of Energy Forms; R-O-W Permit.for new construction, Minimum ten (10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt.Fence Installed, Sanitary Facilities&1 dumpster;Site Work'Permit for subdivislons/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a,Life Safety Page; (1)set of Energy Forms. R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite, Construction Plans,Stormwater Plans w/Silt Fence Installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach (2)sets of Engineered Plans. "PROPERTY-SURVEY required for all NEW construction. )fractions-i-.3-3-0-i..l.-I-S-i=l--i-i-6--6-C-t-B.-i-4-b-.1-1--9--�->�.&-d--� 9-8--@-s-B-6-@-1.6.-➢-4-@-�'•9--I--9�Q.,�-.&.I.� ll�@�--�-@®4 aff--6-n�&-4-�. lfrections: Fill out application completely. Owner Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over$75o0) * Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same )VER THE COUNTER PERMITTING (Copy of contract required) 3eroofs•if shingles • Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) 1:. Driveways-Not over Counter if on public roadways..needs ROW ` . ' NOTICE (3F DEED RESTRICTIONS: The undersigned undnrstandadla1thhspernlitmuybesub^keotto "deed" resthcUone". which may bo more restrictive than County regulations. The undersigned assumes responsibility for dbmp|ianoe with any applicable deed restrictions. . UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSlB|UT\ES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with'state and local regulations. lfthe contractor is not-licensed as required by |aw, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended-contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division--LioenslnQ Section at727-847- ' 8008. Furthermore, if the owner has hired e contractor or oontractors, he is advised to have the contractor(s) u|On portions of the "contractor Block" of this application for which they will be responsible. If you. as the owner sign As the oontnantor, tha1 may be an indication that he is not properly licensed and is not entitled to permitting privileges.in Pasco County. TRANSPORTATION l88P/\CT8JT\L|T(ES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation lmpa:ct Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing bui|d\ngy, as specified in Pasco County Ordinance number 89-07 and 00-07. as amended. The undersigned also understands' that such fees. as may be due' will be identified at the time of permitting. It is further understood that Transportation impact Fees and Resource Recovery Fees. must be paid prior to receiving a ^oertifioata of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power re|e�se, the fees must be paid prior to permit issuance. Furthermore, if Pasco-County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW (Chapter 713. Florida Statutes, asamoandad): !f valuation ofvVorkis $2.5O8.b8or more, ( certify that |, the app|inant, have been provided with a copy of the "FloridaConstruction, Lien Law—Homeowner's ' Protection Guide" prepared by the Florida Department of Agriculture.and Consumer Affairs. If the applicant is oonnamne otharthanthe "owner". | cerUfythot | haveobtainedauopyofthanbuvedeschbeddooumentandpnom|sa |nOooUfaithto deliver itbz the^oxvner" prior hocommencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: | certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a pe'mit to do.work and installation as indicated. | certify that no work or installation has commenced prior to issuance of permit and that all work will be performed to meet standards of all laws regu|a1|ny oonstnuCtion. County and City codes,- zoning regulations; and'land development regulations. \n the jurisdiction. \ also nnrUfv that | understand that the regulations of othe� government agenO\es may apply to the intended wo[k, and that it is myr'spnnsibiUtytn \dentifvvvhat actions ( nnust take tobe \ncompUan'on. Such agandesinclude but are not|}nnitadto: - Department of' Environmental Protection-Cypress Bayhmads. Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. - Southwest Florida* Water Management District-Wells, Cypress. Bayheads, Wetland Areas, A|tednq Watercourses. ' . ' Army Corps of Enginean*8eowaUn, Docks, Navigable Waterways. ' Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment,' ` Septic Tanks. ` ' US1EnviYonmenta\ Pnoteodon Agency-Asbestos abatement. - Federal Aviation /\uthority-Runvvoya. | understand that the following restrictions apply to the use offill: - Use of fill is not allowed in Flood Zone"V" unless expressly permitted. - if the fill rno1eda| is to be used in Flood Zone ^A'. it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a profaasidna| enginee'r licensed by the State ofFlorida. � ' If the fillfillmaterial is to be used in Flood Zone "A. in connection with a.permitted building using stem vvaU construction, I certify that fill will be used only to fill the area within the stem wall. - If fill rna1eda| is to be used in any area, \ certify that use of such fill will not adversely affect adjacent . properties, If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots |aus than one M\ acre which are elevated-by fill, an engineered drainage plan is roqu|ned. |fiumtheAGE0TFORTREOVVNER. | procnieeingoodfaithtninformthomwnerofthopurmitdn0cpndhionsaatforth \n this affidavit prior to commencing construction. i understand that o separate permit may be.required for electrical work' plumbing, signs, wa||s, poo|a, air uondhjoning, gas.,or other |nota\|ebona not specifically included in the application. A permit issued s.ha|| be construed to be a license to proceed with-the work and not as authority to vio|ute, cancel, a|ter, or oat aside any provisions of the technical codam, nor mhu|| issuance of a permit prevent the Building Official from thereafter requiring acorreoti" nofenora |n plans, nnnstruudonor violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within o)X months of permit issuance, or if work authorized by the permit|o suspended or abandoned for apehod^of six (6) months a�or the tinnp the wiork \aoononnenoed. An extension ' may be requested, in writing, from the Building �|ci�< for a period not to exceed ninety (SO) days and will demonstrate � justifiable cause for the.extension, If work ceases for ninety (90) consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT /N YOUR. PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY' IF YOU INTEND TO OBTAIN F\0/\NCJI0G, CO0' DLT . WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF FLORIDA �T`� - 117.0 OWNER OR AGENTCONTRACTOR � � Subscribed and swQQ to(or affirmed)before me this Subscribed and sworn to ` - before-e this by Who is/are personally known to me or has/have-produced vvhuis/am personallyxnnwn to me or has/have identification. as Identification. ` ' N otary PublicNotary Public Commission No. Commission N . ' . _-_of Notary typed,printed_ stamped-_ Oy ' % Notary Public State of Florida My Commission GG 057321 s �. Wt a. �. PASCO COUNTY$ FLORIDA r, Permit No. _ Date Permitted 3�,V-- Builder Name/Owner Name R 46-�hh CSC. Control#' ' County Parcel No. 0,5-2k-2,11006D-00(060--d t D SubDiv: � 0 Address/Location Classification(rype of Use 1q11 Y4 4m, Itf . TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: �,D B5 `. Exempt ❑ Yes ❑ No How Determined i impact Fee Amount $. 2 Zone No. TAZ: SCHOOL IMPACT FEE Account (056) Single-Family Detached House Amount $ (057) Mobile Home (058) Other Residential 9 23) Collection Fee Exempt Yes ❑ No How Determined PARKS AND RECREATION FEE Land Account Land Credit —Land Total Recreation Account Recreation Credit, -Recreation Total Zone TOTAL AMOUNT $. 24. , Exempt ❑ Yes ❑ No How Determined - t_: LIBRARY FEE Land Account Land Credit Land Total j:. Facility Account Facility Credit Facility Total Exempt ❑ Yes ❑ No How Determined Total Amountl'� RESOURCE FEE ERU TOTAL AMOUNT Prepared By Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE.OF PASCO COUNTY Acknowledgement below does not imply acceptance of concurrence,but simply receipt of-a copy of this form,placing the building permit owner on notice of this assessment and the conditions of payment for same. DATE RECEIVED BY RECEIPT NO. DATE BY PLOT PLAN'. DESCRIPTION:(AS FURNISHED) LOT 15, BLOCK 6, SILVERADO RANCH SUBDIVISION PHASE 6, 8 & 9A AS RECORDED IN PLAT BOOK 75, PAGE(S) 75-80, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. Line Table Line # Direatlon Length L1 I N53-35-22•W 1 10.30' Curve Table , g PRIVATRACT Curve B Length Radlue Delta Chord Beorin Chord DRAINAGE AREA C7 1 45.71' 1 100.00'1 26-11'29• N66.41-06•W 45.32' ,05:5 S83'59'36" E 68.09' ui -7 o \ 40 / 40 d O�gsSS c�'S lot Z �� BR• NACF O F 6' / T 1 — 30' GRAPHIC SCALE 0 15 30 / ,yop 0 B �.> \ 2i �O+Ae O�G�(o 10.1O A FOP % F O 16 �0 o N y e ICJ o832 ON LOT CALCULATIONS LOT = 7,455 SO. FT. •� LIVING AREA = 1,104 SO. FT. GARAGE = 437 SQ. FT. cl,O i ym ao ENTRY = 53 SQ. FT. LANAI = 0 SQ. FT. PATIO = 80 SO. FT. DRIVEWAY 426 SQ. FT. �oq�cySl,Q �s� A/C PAD = 12 SQ.'FT. WALKWAY = 30 SQ. FT. IMPERVIOUS = 29% q} \ = 2142 SQ. FT. 5,31 C s SOD = 313 SQ. FT. OFF LOT CALCULATIONS T�ok,r RIGHT OF WAY = 694 SQ. FT. [y DRIVE APRON = SQ. FT. PREPARED FOR: 4} \ �� RP PUBLIC S/W = 280 SQ. FT. SOD = 414 SQ. FT. D R•H[IWN' �y0 TOTALS �Vtik awl—ica's;ouf;vv I AREA = 8,149 SQ. FT. DRIVEWAY = ### SQ. FT. BUILDING SETBACKS SIDEWALK =.310 SQ. FT. FRONT: 20' SOD = 5,727 SQ. FT. REAR: 15' SIDE: 7.5' SIDE STREET: 20' LEGEND: NOTES:, — BUILDING SETBACK LINE PI POINT OF INTERSECTION PC POINT OF CURVATURE 1. ELEVATIONS SHOWN ARE PER LOT GRADING — CENTERLINE PT POINT OF TANGENCY PLANS PROVIDED BY THE CLIENT. — — — — RIGHT OF WAY LINE RP RADIUS POINT 2. ELEVATIONS ARE BASED ON NAVD 1988 XX PRC POINT'OF REVERSE CURVATURE DATUM. PROPOSED ELEVATION PCC POINT OF COMPOUND CURVATURE TYP TYPICAL PROPOSED DRAINAGE FLOW CS CONCRETE SLAB THIS PLOT PLAN IS INTENDED FOR PERMITTING PURPOSES 0 CONCRETE (P) PER PLAT CALCULATED ONLY. THIS IS NOT INTENDED FOR THE CONSTRUCTION OF PS PUT BOOK THE PROPOSED HOUSE. REFER TO HOUSE PLAN AND A/C AIR CONDITIONER PGS PAGES OPTION LIST FOR CONSTRUCTION. ALL BUILDING SET BACK S/W SIDEWALK SO. FT. SQUARE FEET LINES SHOWN HEREON IS PER DATA FURNISHED BY CLIENT F.E.M.A. FEDERAL EMERGENCY MANAGEMENT AGENCY AND IS FOR INFORMATIONAL PURPOSES ONLY. F.I.R.M. FLOOD INSURANCE RATE MAP. NAVD NORTH AMERICAN VERTICAL DATUM THIS IS NOT A SURVEY NGVD NATIONAL GEODETIC VERTICAL DATUM D&UE DRAINAGE&UTILITY EASEMENT THIS IS A PLOT PLAN ONLY POE PRIVATE DRAINAGE EASEMENT UE UTILITY EASEMENT(PUBLIC) FLOOD NOT9: SURVEYOR NOTES: I HAVE EXAMINED THE F.I.R.M. MAP NO. 12101CO288F, 1. THE SURVEYOR HAS NOT-ABSTRACTED THE " DATED SEPTEMBER 26, 2o14, AND FOUND THE SUBJECT PROPERTY LAND SHOWN HEREON FOR EASEMENTS, RIGHT APPEARS TO LIE IN ZONE'X•, AREAS DETERMINED TO-BE OUTSIDE THE OF WAY, RESTRICTIONS OF RECORD WHICH 0.2%ANNUAL CHANCE FLOODPLAIN. THE SURVEYOR MAKES NO MAY AFFECT THE TITLE OR USE OF THE LAND. GUARANTEES AS TO THE ABOVE INFORMATION. PLEASE CONTACT THE LOCAL F.E.M.A. AGENT FOR VERIFICATION. 2. NO UNDERGROUND IMPROVEMENTS HAVE BEEN BEARING BASIS: LOCATED-EXCEPT AS SHOWN. A5flA BEARINGS SHOWN HEREON ARE BASED ON THE CENTERUNE OF WAGON 3. NOT VALID WITHOUT THE AUTHENTIC TRAIL STREET BEING N53.35'22•W, PER PLAT. ELECTRONIC SIGNATURE AND THE AUTHENTIC A M [—:= R I CA N ELECTRONIC SEAL OF A FLORIDA LICENSED (FIELD DATE:) .REVISED: ` ' A , SURVEYOR AND MAPPER. SU R V EYI ,V G Dlgltallysigned byJammW SCALE: 1•- 30 FEET e"•c::';ea Boleman • f " " DN:cn=JamesWBoleman, APPROVED BY: JB MAPPING INC. ,.sau o=American Surveying& CERTIFICATION OF AUTHORIZATION NUMBER U3#6393 Ct '`Mapping,ou, 3191 MAGUIRE BOULEVARD, SUITE 200 :�`m jag email:Jboleman@asmcorporate.c FOR (407) 426-7979 171013 LOT 15, ELK 6 om,c=US• JOB NO. ORLAND FLORID 32803 moon '% Date:2017.11.1609:25:21-05'00' FIRM DRAWN BY: DSB PLOT PLAN 11 10 17 KJW WWW.AMERICANSURVEYINGANDMAPPING.COM JAMES W. BOLEMAN PSM# 6485 DATE FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Hayden 2605 Elev C Builder Name: DR Expres Homes / Street: �� 2� l.L� o'1��'�,I S ^ Permit Office: ( 0` ze r� Mt�t'U City,State,Zip: Zep yrhills, FL, y/\\( � Permit Number: JC� Owner: - �41 ��l Jurisdiction: 6 0 Design Location: FL,Tampa \\ County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(2614.2 sgft.) Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1285.30 ft2 b.Concrete Block-Int Insul,Exterior R=4.1 996.67 ft2 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 332.22 ft2 4. Number of Bedrooms 5 d.N/A R= ft2 10.Ceiling Types (1541.0 sqft.) Insulation Area 5. Is this a worst case? No a.Under Attic(Vented) R=30.0 1541.00 ft2 6. Conditioned floor area above grade(ft2) 2605 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 11. Duuctct c. R= ft2 s R ft2 7. Windows(250.0 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 261 a. U-Factor: Dbl,U=0.34 210.00 ft2 SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.55 40.00 ft2 12.Cooling systems kBtu/hr Efficiency a.Central Unit 40.0 SEER:14.00 SHGC: SHGC=0.34 c. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 4.1.0 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 1.052 ft. Area Weighted Average SHGC: 0.315 14. Hot water systems 8. Floor Types (1541.0 sg a.Electric Cap:50 gallons ft.) Insulation Area EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1104.00 ft2 b. Conservation features b.Raised Floor R=19.0 437.00 ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.096 Total Proposed Modified Loads: 78.45 PASS Total Baseline Loads: 79.15 I hereby certify that the plans and specifications covered by Review of the plans and o.14E S'r this calculation are in compliance with the Florida Energy specifications covered by this �;� Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: Before construction is completed c �, DATE: 1t-9-17 this building will be inspected for 'Ivp ,ie compliance with Section 553.908 * ° I hereby certify that this building,as designed, is in compliance Florida Statutes. with the Florida Energy Code. G'OD WE OWNER/AGENT: �� �1'Sn 4 BUILDING OF ICIAL: DATE: Ii �y DATE: - Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. - Compliance with a proposed duct leakage fin requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with Section 803 of RESNET Standards, is not greater than 0.060 fin for whole house. 1 1/9/201 7 9:11 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2014. FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION , Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Hayden 2605 Elev C Builder Name: DRH Express Homes Street: (fc, 26 l�� rn_�/��I S� �� Permit Office: City,State,Zip: Zephyrhills, FL, / Permit Number: Owner: CSC t I �51 Jurisdiction: Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(2614.2 sgft.) Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood, Exterior. R=11.0 1285.30 ftz b.Concrete Block-Int Insul,Exterior R=4.1 996.67 ftz 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 332.22 ftz 4. Number of Bedrooms 5 d.N/A R= ftz 10.Ceiling Types (1541.0 sgft.) Insulation Area 5. Is this a worst case? No a.Under Attic(Vented) R=30.0 1541.00 ft2 6. Conditioned floor area above grade(ftz) 2605 b.N/A R= ftz Conditioned floor area below grade(ftz) 0 c.N/A R= ftz 11. Ducts R ftz 7. Windows(250.0 sqft.) Description Area a.Sup:Attic, Ret:2nd Floor,AH:2nd Floor 6 261 a. U-Factor: Dbl,U=0.34 210.00 ftz SHGC: SHGC=0.31 b. U-Factor: Dbl, U=0.55 40.00 ftz 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.34 a.Central Unit 40.0 SEER:14.00 c. U-Factor: N/A ftz SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ftz a.Electric Heat Pump 4.1.0 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 1.052 ft. Area Weighted Average SHGC: 0.315 14.Hot water systems 8. Floor Types (1541.0 sgft.) Insulation Area a. Electric Cap:50 gallons a.Slab-On-Grade Edge Insulation R=0.0 1104.00 ftz b. Conservation features EF:0.950 b.Raised Floor R=19.0 437.00 ftz None c.N/A R= ftz 15.Credits Pstat Glass/Floor Area: 0.096 Total Proposed Modified Loads: 78.45 PASS SS Total Baseline Loads: 79.15 /`� I hereby certify that the plans and specifications covered by Review of the plans and -&'SHE SF this calculation are in compliance with the Florida Energy specifications covered by this =_ 0 Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: L ri4-SQ„ Before construction is completed r DATE: -g-t7 this building will be inspected for 0I :" ,ie compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. j with the Florida Energy Code. ,,� �'OD WE OWNER/AGENT: -- /vim/` BUILDING WFA DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler Enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with Section 803•of RESNET Standards,is not greater than 0.060 Qn for whole house. 1 1/9/201 7 9:11 AM EnergyGauge@ USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2014 PROJECT Title: Hayden 2605 Elev C Bedrooms: 5 Address Type: Lot Information Building Type: User Conditioned Area: 2605 Lot# 15/6 Owner: Total Stories: 2 Block/Su bDivision: Silverado Ranch #of Units: 1 Worst Case: No PlatBook: Builder Name: DRH Express Homes Rotate Angle: 225 Street: Permit Office: Cross Ventilation: County: Pasco Jurisdiction: Whole House Fan: City,State,Zip: Zephyrhffls, Family Type: Single-family FL, New/Existing: New(From Plans) Comment: Garage L Face SW CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Tampa FL_TAMPA_INTERNATI 2 39 91 70 75 645.5 54 Medium BLOCKS Number Name Area Volume 1 Blocki 2605 21579.7 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1104 9571.7 Yes 1 1 1 Yes Yes Yes 2 2nd Floor 1501 12008 No 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio Main 152.8 ft 0 1104 ftz ____ 0.2 0 0.8 2 Raised Floor 2nd Floor ____ ____ 437 ft2 19 0.5 0 0.5 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1723 ftz 0 ftz Dark 0.92 No 0.9 No 0 26.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 1541 ftz Y N 1 1/9/201 7 9:11 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2014 CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) Main 30 Blown 40 ft2 0.11 Wood 2 Under Attic(Vented) 2nd Floor 30 Blown 1501 ft2 0.11 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 N=>SW Exterior Concrete Block-Int Insul Main 4.1 18 8 8 8 161.8 ft2 0 0.6 0 2 E=>NW Exterior Concrete Block-Int Insul Main 4.1 20 8 8 173.3 ft2 0 0.6 0 _3 S=>NE Exterior Concrete Block-Int Insul Main 4.1 39 8 8 8 343.8 ft2: 0 0.6 0 4 W=>SE Exterior Concrete Block-Int Insul Main 4.1 36 8 8 8 317.8 ft2 0 0.6 0 5 N=>SW Garage Frame-Wood Main 11 20 4 8 8 176.2 ft2 0.23 0.01 0 6 E=>NW Garage Frame-Wood Main 11 18 0 8 8 156.0 ft2 0.23 0.01 0 7 N=>SW Exterior Frame-Wood 2nd Floor 11 39 8 8 317.3 ft2 0.23 0.6 0 8 E=>NW Exterior Frame-Wood 2nd Floor 11 40 8- 8 325.3 ft2 0.23 0.6 0 9 S=>NE Exterior Frame-Wood 2nd Floor 11 39 8 8 317.3 ft2 0.23 0.6. 0 10 W=>SE Exterior Frame-Wood 2nd Floor 11 40 8 8 325.3 f12 0.23 0.6 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N=>SW Insulated Main None .4 3 6 8 20 ft2 2 N=>SW Wood Main None .46 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered orientation => changed to As Built rotated 225 degrees). Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N=>SW 1 Vinyl Low-E Double Yes 0.34 0.31 31.0 ft2 1 ft 0 in 10 ft 0 in Drapes/blinds None 2 N=>SW 1 Vinyl Low-E Double Yes 0.34 0.31 2.5 ft2 6 ft 2 in 0 ft 0 in Drapes/blinds None 3 S=>NE 3 Vinyl Low-E Double Yes 0.34 0.31 46.5 ft2 1 ft 0 in 10 ft 6 in Drapes/blinds None 4 S=>NE 3 Metal Low-E Double Yes 0.55 0.34 40.0 ft2 1 ft 0 in 1 ft 3 in Drapes/blinds None 5 N=>SW 7 Vinyl Low-E Double Yes 0.34 0.31 6.0 ft2 1 ft 0 in 0 ft 6 in Drapes/blinds None 6 N=>SW 7 Vinyl Low-E Double Yes 0.34 0.31 31.0 ft2 1 ft 0 in 2 ft 6 in Drapes/blinds None 7 S=>NE 9 Vinyl Low-E Double Yes 0.34 0.31 62.0 ft2 1 ft 0 in 0 ft 6 in Drapes/blinds None 8 N=>SW 7 Vinyl Low-E Double Yes 0.34 0.31 31.0 ft2 1 ft 0 in 0 ft 6 in Drapes/blinds None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 437.038 ft2 437.038 ft2 48.4 ft 8.67 ft 0 1 1/9/201 7 9:11 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2014 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000368 2517.6 138.21 259.93 .3402 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump None HSPF:8.2 41 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Black Ducts 1 Central Unit None SEER:14 40 kBtu/hr 1200 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 50 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS / ----Supply---- ----Return---- Air CFM 25 CFM25 HVAC# �/ # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 261 ft2 2nd Floor 45 ft2 Proposed Qn 2nd Floor ---cfm 156.3 cfm 0.06 0.60 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Coolingr Jan Feb r l Mar A r ( May [X]Jun rX�Jul AugrX�Se r Oct Nov Dec Heatin [X}Jan H Feb l Mar Apr [ May [ ]Jun [ ]Jul l Au [ ]SeP [ Oct Nov Dec Ventin [[[ ]Jan Feb [[[[XXXX]]]]Mar Apr [ ]]]May [ ]Jun [[[ ]Jul l Aug [[[ ]Se [[[XXX]]]Oct HX Nov Dec 11/9/2017 9:11 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2014 Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(W D) AM . 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68- 68 66 66 11/9/2017 9:11 AM EnergyGauge@ USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5 FORM R405-2014 'ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the EnergyPerformance Index,the more efficient the home. Zephyrhills, FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Frame-Wood,Exterior R=11.0 1285.30 ftZ b.Concrete Block-Int Insul,Exterior R=4.1 996.67 ft 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 332.22 ftz 4. Number of Bedrooms 5 d.N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types Insulation Area a.Under Attic(Vented) R=30.0 1541.00 ftz 6. Conditioned floor area(ftz) 2605 b.N/A R= ftz 7. Windows" Description Area c.N/A R= ftzz a. U-Factor: Dbl,U=0.34 210.00 ftz 11. Ducts R - ft a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 261 SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.55 40.00 ftz SHGC: SHGC=0.34 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ftz a.Central Unit 40.0 SEER:14.00 SHGC: d. U-Factor: N/A ftz 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 41.0 HSPF:8.20 Area Weighted Average Overhang Depth: 1.052 ft. Area Weighted Average SHGC: 0.315 8. Floor Types Insulation Area 14.Hot water systems Cap:50 gallons a.Slab-On-Grade Edge Insulation R=0.0 1104.00 ftz a.Electric EF:0.95 b.Raised Floor R=19.0 437.00 ftz c.N/A R= ftz b. Conservation features None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building o IHE Sr4p ' Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Date: Address of New Home: �i' ` - City/FL Zip: co1)W-k 'Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. "Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 1 1/9/201 7 9:11 AM EnergyGauge@ USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 • 4 FORM R405-2014 Florida Department of Business and Professional Regulations Residential Whole Building Performance and Prescriptive Methods ADDRESS: Permit Number: Zephyrhills,FL, MANDATORY REQUIREMENTS See individual code sections for full details. 401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law [Section 553.9085,Florida Statues]requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit.The building official shall verify that the EPL'display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix C. R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.1 through R402.4.4. O R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.The sealing-methods between dissimilar materials shall allow for differential expansion and contraction. R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in.' accordance with the manufacturer's instructions and the criteria listed in Table 402.4.1.1,as applicable to the method of construction. Where required by the code official,an approved third party shall inspect all components and verify compliance. R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2,and 3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3. Interior doors,if installed at the time of the test,shall be open; 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. O R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers and outdoor combustion air. O R402.4.3 Fenestration air leakage.Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot(1.5 Uslm2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400 or AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. O R402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential.All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. R403.2.2 Sealing(Mandatory)AII ducts,air handlers,and filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post-construction or rough-in testing below. Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either an energy rater certified in accordance with Section 553.99,Florida Statutes,or as authorized by Florida Statutes,to be"substantially leak free"by either of the following: 1. Post-construction test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25 Pa)across the entire system,including the manufacturer's air handler'enclosure.All register boots shall be taped or otherwise sealed during the test. 2. Rough-in test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(2510a)across the system,including the manufacturer's air handler enclosure.All registers shall be taped or otherwise sealed during the test.If the air handler is not installed at the time of the test,total leakage shall be less than or equal to 3 cfm (85 Umin)per 100 square feet(9.29 m2)of conditioned floor area. Exceptions: 1. The total leakage test is not required for ducts and air handlers located entirely within the building envelope. 2. Duct testing is not mandatory for buildings complying by Section R405 of this code. 11/9/2017 9:11 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Com Page 1 of 3 FORM R405-2014 MANDATORY. REQUIREMENTS - (Continued) ❑ R403.2.3 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. ❑ R403.3 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C) or below 55°F(13°C)shall be insulated to a minimum of R-3., R403.3.1 Protection of piping insulation. ❑ R403.4.1 Circulating hot water systems(Mandatory). Circulating hot water systems shall be provided with an automatic or readily accessible manual switch that can turn off the hot-water circulating pump when the system is not in use. ❑ R403.4.3 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3 1/2 inches(89 mm)in the hot water distribution line and cold water line located as close as possible to the storage tank. ❑ R403.4.4 Water heater efficiencies(Mandatory). O R403.4.4.1 Storage water heater temperature controls • R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature setting range shall be from 100°F to 140°F(38°C to 60oC). • R403.4.4.1.2 Shutdown. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s) of combustion types of service water heating systems to be turned off. O R403.4.4.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed. .Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1. R403.4.4.2.1 Solar water heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors, and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol,Collectors in installed solar water heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and 2. Be installed at an orientation within 45 degrees of true south. ❑ R403.5 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code,Residential or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. ❑ R403.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment. O R403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1.This code does not allow designer safety factors,provisions for future expansion or other factors which affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. R403.6.1.1 Cooling equipment_capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load,but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.6,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load. 11/9/2017 9:11 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Com Page 2 of 3 FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) 0 R403.6.1.1 Cooling equipment capacity.(continued) The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacture's expanded performance data shall be used to select cooling-only equipment.This selection shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower cfm provided by the expanded performance data, the design value for entering wet bulb temperature and the design value for entering dry bulb temperature. Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space. Exceptions: 1. Attached single-and multi-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida-registered engineer,in attached single-and multi-family units,the capacity of equipment may be sized in accordance with good design practice. 0 R403.6.1.2 Heating equipment capacity R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section R403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load. . R403.6.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.6.1. R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.6.1. 0 R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. ❑ R403.7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the Commercial Provisions in lieu of Section R403. ❑ R403.8 Snow melt system controls(Mandatory). Snow and ice-melting systems,supplied through energy service to the building,shall include automatic controls capable of shutting off the system when the pavement temperature is above 55°F,and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F. ❑ R403.9 Swimming pools,inground spas and portable spas(Mandatory). The energy requirements for residential pools and inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSI/APSP-15.The energy requirements for portable spas shall be in accordance with ANSI/APSP-14. O R403.9.1 Pool and spa heaters.' All pool heaters shall be equipped with a readily accessible on-off switch that is mounted outside the heater to allow shutting off the heater without adjusting the thermostat setting. R403.9.1.1 Gas and oil-fired pool and spa heaters. All gas-and oil-fired pool and space heaters shall have a minimum thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013 when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights. R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. O R403.9.2 Time switches. Time switches or other control method that can automatically turn off and on heaters and pumps according to a preset schedule shall be installed on all heaters and pumps.Heaters,pumps and motors that have built in timers shall be deemed in compliance with this equipment. Exceptions: 1. Where public health standards require 24-hour pump operations. 2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation. O R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Outdoor pools deriving over 70 percent of the energy for heating from site-recovered energy,such as a heat pump or solar energy source computed over an operating season. ❑ RR404.1 Lighting equipment(Mandatory). A minimum of 75 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps. Exception: Low-voltage lighting shall not be required to utilize high-efficacy lamps. 0 R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights ❑ R405.2 Performance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R-6. O ,R405.2.1 Performance ONLY. Ceilings shall have minimum insulation of R-19.Where single assemby of the exposed deck and beam type or concrete deck roofs do not have sufficent space, R-10 is allowed. 11/9/2017 9:11 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Com Page 3 of 3 FORM R405-2014 TABLE.402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Hayden 2605 Elev C Builder Name: DRH Express Homes Street: : Permit Office: City,State,Zip: Zephyrhills,FL, Permit Number: Owner: Jurisdiction: Design Location: FL,Tampa COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows,skylights and doors The space between window/door jambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air,barrier. Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations,and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated,and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 1 1/9/201 7 9:11 AM EnergyGauge@ USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Envelope Leakage Test Report Prescriptive and Performance Method Project Name: Hayden 2605 Elev C Builder Name: DRH Express Homes Street: Permit Office: City,State,Zip: Zephyrhills, FL, Permit Number: Design Location: FL,Tampa Jurisdiction: Cond.Floor Area:: 2605 sq.ft. Cond.Volume: 21580 cu ft. Envelope Leakage Test Results Leakage Characteristics Regression Data: C-: n. R: CFM(50): Single or Multi Point Test Data HOUSE PRESSURE FLOW: ELA' 1 Pa cfm EgLA: 2 Pa cfm ACH: 3 Pa cfm ACH(50): 4 Pa cfm 5 Pa cfm SLA. 6 Pa cfm R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2,3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3.Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. I hereby certify that the above envelope leakage Where required by the code official, O�SKE STATE performance results demonstrate compliance testing shall be conducted by an with Florida Energy Code requirements in approved third party. A written accordance with Section R402.4.1.2. report of the results of the test shall be signed by the third party jslfF o conducting the test and provided to SIGNATURE: the code official. f�c'ab WE"���tS PRINTED NAME: BUILDING OFFICIAL: DATE: DATE: 11/9/2017 9:11 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 Duct Leakeige Test Report Performance Method FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Form R405 Duct Leakage Test Report — Performance Method Project Name: Hayden 2605 Elev C Builder Name: DRH Express Homes Street: Permit Office: City,State,Zip: Zephyrhills, FL, Permit Number: Design Location: FL,Tampa Jurisdiction: Duct Test Time: Post Construction Duct Leakage Test Results CFM25 Duct Leakage Test Values Line System Outside Duct Leakage 1 System 1 -cfm25(Out) 2 System 2 cfm25(Out) 3 System 3 cfm25(Out) 4 System 4 cfm25(Out) 5 Total House Sum lines 1-4 Duct System Divide by Leakage (Total Conditioned Floor Area) (Qn,Out) I certify the tested duct leakage to outside, Qn, is not greater than the proposed duct leakage Qn Duct tightness shall be verified by ottl4E S specified on Form R405-2014. testing to Section 803 of the RESNET 0 Standards by an energy rater certified in 14. accordance with Section 553.99, 'It Florida Statutes. 04 lift" SIGNATURE: PRINTED NAME: WE DATE: BUILDING OFFICIAL: DATE: .11/9/2017 9:11 AM EnergyGauge@ USA-FlaRes2014 Section R405.4.1 Compliant S Page 1 of 1 Manual S Compliance Report Job: - - Wrlghtsoft® p p - Date: oCt 10,2014 Entire House By: Progressive Air Systems, Inc 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 Proect Information, For: DR Horton/Express Lot 15 Blk 6 Silverado Ranch, Zephyrhills, FL • • • • • Design'Conditions Outdoor design DB: 91.2°F Sensible gain: 29932 Btuh Entering coil DB: 76.4°F Outdoor design WB: 77.1 OF Latent gain: 4144 Btuh Entering coil WB: 63.2°F Indoor design DB: 75.0°F Total gain: 34075 Btuh Indoor RH: 50% Estimated airflow: 1367 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB042****A+FB4CNP042 Actual airflow: 1367 cfm Sensible capacity: 32445 Btuh 108%of load Latent capacity: 6269 Btuh 151%of load Total capacity: 38714 Btuh 114%of load SHR: 84% Heatir)g Ouipment, Design Conditions Outdoor design DB: 40.0°F Heat loss: 27149 Btuh Entering coil DB: 69.5°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB042****A+FB4CNP042 Actual airflow: 1367 cfm Output capacity: 37299 Btuh 137%of load Capacity balance: 31 OF Supplemental heat required- 0 Btuh Economic balance: -99 OF Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 1367 cfm Output capacity: 8.6 kW 108%of load Temp. rise: 18 OF Meets are all requirements of ACCA Manual S. wri htsoft3 2017-Nov-09 09:13:06 9 Right-Suite®Universal 2017 17.0.21 RSU25554 Page 1 ...\Wrightsoft Files\Express homes\Hayden-4EHB.rup Calc=MJ8 House faces:SW Load Short Form Job: 1- wrightsofte Date: Oct 10,2014 Entire House By: Progressive Air Systems, Inc 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 Project • • For: DR Horton/Express Lot 15 Blk 6 Silverado Ranch, Zephyrhills, FL Dpsign Inforhiation Htg Clg Infiltration Outside db(°F) 40 91 Method Simplified Inside db(°F) 70 .75 Construction quality Semi-tight Design TD (°F) 30 16 Fireplaces 0 Daily range - L Inside humidity (%) 50 50 Moisture difference(gr/lb) 26 54 HEATING EQUIPMENT COOLING EQUIPMENT Make Carrier Make Carrier Trade CARRIER Trade CARRIER Model C H 1 4N B042****A Cond CH14NB042****A AHRI ref Coil FB4CNP042 AHRI ref Efficiency 8 HSPF Efficiency 11.3 EER, 13.7 SEER Heating input Sensible cooling 30750 Btuh Heating output 38500 Btuh @ 47°F Latent cooling 10250 Btuh Temperature rise 26 OF Total cooling 41000 Btuh Actual air flow 1367 cfm Actual air flow 1367 cfm Air flow factor 0.050 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0.56 in H2O Static pressure 0.56 in H2O Space thermostat Load sensible heat ratio 0.88 Capacity balance point=31 OF Backup: Input=9 kW, Output= 29290 Btuh, 100 AFUE ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) kitchen/living 608 7370 7923 371 362 bed 2 164 2960 1826 149 83 powder 59 968 395 49 18 flex 156 3106 2821 156 129 foyer 75 1443 953 73 44 stairs 44 0 0 0 0 bed4 181 1647 2049 83 . 94 bed3 184 1965 2959 99 135 wic 60 143 190 7 9 wic 2 32 706 810 36 37 m suite 277 2507 3719 126 170 bath 135 355 381 18 17 upstairs living 234 1366 2320 69 106 stairs 2 50 0 0 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wri htsoft� 2017-Nov-09 09:13:06 9 Right-Suite®Universal 2017 17.0.21 RSU25554 Page 1 ACC& ...\Wrightsoft Files\Express homes\Hayden-4EHB.rup Calc=MJ8 House faces:SW �bed5 175 1606 2002 81 91 laundry 41 368 985 19 45 a/c, 19 0 0 0 0 bath 3 96 639 600 32 27 hall 63 0 0 0 0 Entire House d 2651 271491 29932 1367 1367 Other equip loads 0 0 Equip. @ 1.00 RSM 29932 Latent cooling 4144 TOTALS 2651 27149 34075 1367 1367 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. ri htsoft` 2017-Nov-09 09:13:06 w 9 Right-Suite®Universal 2017 17.0.21 RSU25554 Page 2 AGM ...\Wrightsoft Files\E)press homes\Hayden-4EHB.rup Calc=MJ8 House faces:SW 1 rotect Summary Wrightsoft® P y Date: Oct 10,2014 Entire House By: Progressive Air Systems, Inc 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 Prosect Information, For: DR Horton/Express Lot 15 Blk 6 Silverado Ranch, Zephyrhills, FL Notes: Ddsiqn. ormation Weather: Tampa Intl AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 40 OF Outside db 91 OF Inside db 70 OF Inside db 75 OF Design TD 30 OF Design TD 16 OF Daily range L Relative humidity 50 % Moisture difference 54 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 20520 Btuh Structure 20961 Btuh Ducts 6629 Btuh Ducts 8971 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 27149 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 29932 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality- Semi-tight Fireplaces 0 Structure 2674 Btuh Ducts 1469 Btuh Central vent (0 cfm) 0 Btuh Heatin Coolingg (none) Area(ft2 2651 2651 Equipment latent load 4144 Btuh Volume(ft3) 22094 22094 Air changes/hour 0.22 0.11 Equipment total load 34075 Btuh Equiv.AVF(cfm) 81 41 Req. total capacity at 0.75 SHR 3.3 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER Trade CARRIER Model CH14NB042****A Cond CH14NB042****A AHRI ref Coil FB4CNP042 AHRI ref Efficiency 8 HSPF Efficiency 11.3 EER, 13.7 SEER Heating input Sensible cooling 30750 Btuh Heating output 38500 Btuh @ 470F Latent cooling 10250 Btuh Temperature rise 26 OF Total cooling 41000 Btuh Actual air flow 1367 cfm Actual air flow 1367 cfm Air flow factor 0.050 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0.56 in H2O Static pressure 0.56 in H2O Space thermostat Load sensible heat ratio 0.88 Capacity balance point=31 OF Backup: Input=9 kW, Output= 29290 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wri htsoft' 2017-Nov-09 09:13:06 �� 9 Right-Suite®Universal 2017 17.0.21 RSU25554 Page 1 ..\Wrightsoft Files\Express homes\Hayden-4EHB.rup Calc=MJ8 House faces:SW FORM R405-2014 RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST Florida Department of Business and Professional Regulation Simulated Performance Alternative(Performance)Method Applications for compliance with the 2014 Florida Building Code, Energy Conservation via the residential Simulated Performance method shall include ❑ This checklist ❑ A Form R405 report that documents that the Proposed Design complies with Section R405.3 of the Florida Energy Code. This form shall include a summary page indicating home address, a-ratio and the pass or fail status along with summary areas and types of components, whether the home was simulated as a worst-case orientation, name and version of the compliance software tool, name of individual completing the compliance report(1 page)and an input summary checklist that can be used for field verification (usually 4 pages/may be greater). ❑ Energy Performance Level(EPL) Display Card(one page) ❑ Mandatory Requirements(three pages) Required prior to CO for the Performance Method: ❑ Air Barrier and Insulation Inspection Component Criteria checklist(Table R402.4.1.1 - one page) ❑ A completed Envelope Leakage Test Report(usually one page) ❑ If Form R405 duct leakage type indicates anything other than "default leakage", then a completed Form R405 Duct Leakage Test Report(usually one page) EnergyGauge®-USRCZB v5.1 1 1/9/201 7 10:27:28 AM Page 1 of 1 ��J�11,�11,i�Il,�d,tlt This home has been professionally insulated %e/ith Owens Corning a PROPINKO L77 Loosef ll Insulation Gob Site Address) s Name Address City State Zip Owens Corning"' PROPINk"3 L77 Loosefili Insulation Owens Cornin,Insulating Systems,LLC will accept no responsibility when the product is not installed in accordance with the product label.Stated R-value's provided by installing the required number of bags at a thickness not less than the labeled minimum thickness.installation of the required number of bags may yield more than the speciiled minimum t iciness.Failure by the installer to provide both the required bags and at least the minimum thickness will result in lower insulation R-value. spedficsticn=or Open Blow Attic; cs3cs- 'Nabs -!a?,c?e� Ifamirm:4c 1ra:mm7fignd I6:Foon �Ifmaa;cnfaf.- lealfa! -Gmity -Uer>;a'?� �hr- Ikrv�un• � knlue ea00:gre _fara•+�e_. _t4F. 1Ric=_101 .-1M1idies' taiee hudw, T4dmea AtevCcns;r.C'cn A.13 55 1T9 (Il86 +..75 4J5 14 ZK+ 35' 13 87a 115 0,37g Retreat RA9 V 12i2 o2n6 6.7s a75 is N4 35 15 75.4. 133 1) g"L7. 9.4 1063 03:1 7.75 7.75 "`a Numberorba;sused 6 3s Z3 49.2 20.3 O.o7t -Q--i3 11:. 89.4 02163 M 9.^.0 n 2e6 5.5 33 55a I3.r Rdmamd R-•ralue of R-30 13.0 77a 0.429 I0:5 i0S 0596 arancus nsulaOcn 3 7s6 55 1.4 5I i 19A---- 0,6aZ R-38 163 575 W55 12.75 1275 24 2* 55 1.3 4C4 ?5;] 0.825 M3cFcciz:}e fsq.rtj_/'. I /! RAJ, MA 49.3 V.2 1475 t475 Tt:+s�raducc�f:cwsre atbFe;=_d'rng. R 49 VA 4+2 0.7+7 !S25 r6 5 Gth r:/pe(s)of ,R-60 785 35.F 0.9j0 19_0 19_0 insutatcn in coat it Tniduhess of irsulaucn /v`-- Cathedral Ceiling � _ _ Floor_ _ - Dath ar,or=•:duos I�i6w� levltd i6uiry Ifu�un c;i Ir.am nr lh' T Ifauawi buc ded km 7 insulation : 4 coke Wdnar tbs_3 r OL is &mV hr bC tOta k k hr k k ; rm iiinneax ISc hr Cade Ca+m;e hr}a{ -I8¢Q' 15•wt M°the . 3o Z13 i 5 39.0 35s 0346 -30 2x8 I.+ 39.0 2s 0346 38 2x10 r.4 30.6 32.7 1079 38 2x10 1.4 70.6 3Z7 L0 9 49 37 12 13 185. 54.0 1.781. 46 2x!2_ 1.4 M 393 1311 Owens Comin;"glass riber blanket and loosefill thermal insulations,when installed perthe manufacturers'coverage charts and re-commendations.will provide the labeled R•valua THE FOLLOWING PRODUCTS HAVE BEEN INSTALLED IN THIS HOUSE. Kraft Unfazed Fail Loosefill FS-25 R•Yalue Thickness No.pkgs. Coverage Area Ceilings ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Floors ❑ El ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ l Walls ❑ ❑ CI ❑ ❑ :,„,J� ❑ ❑ ❑ ❑ ❑ Basement ❑ ❑ ❑ Q ❑ Q ❑ ❑ ❑ ❑ Crawlspace ❑ ❑ ❑ ❑ ❑ ----- -- ❑. ❑ ❑ ❑ - ❑ r Attic ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ Contractor Date Builder Date aniellasulatio C- �.l Company 1.2939 Dili Company Address C2eaiwa� ;�J71 33762 Address ($ignam(e) 13)223-5094 Phone Phone OWENS CORNING INSULATING SYSTEMS,LLC ONE OWENS CORNING PARKWAY 1 . TOLEDO,OHIO,USA43659 Pub.No.10018804-8,Printed inU.S.A.November 2015.The color PINK isa n 1-800-GET-PINK' registered rrademarkof^vvans Corning.O2015Owans'CorningInsulating 1,vww.owens earn inq,ct7r' Systems,LLC.AII ved. 5335 -8TH STREET • (813)780-0020 CERTIFICATE OF OCCUPANCY Address: 6526 WAGON TRAIL ST Owner: D R HORTON INC ZEPHYRHILLS, FL. 12602 TELCOM DR Subdiv: SILVERADO TEMPLE TERRACE FL 33637-0935 Parcel: 05-26-21-0080-00600-0150 Work Type: 101-NEW CONST/SFR Construction Type: NOT APPLICABLE ❑ Sprinklers Use Classification: NOT APPLICABLE Permit Number: 19461 Date: /1 / 018 i ISSUED B)o BUILD)WOFFICIAL : WATER MUST BE CHANGED OVER WITHIN 10 DAYS OFLSSUANC E GARBAGE DEPOSIT MUST BE APPLIED FOR PRIOR TO ISSUANCE ENVIRONMENTS FOR SITE ID:365305 LOT:15 BLOCKS HOUSE:6526 STREET:WAGON TRAIL ST CITY:ZEPHYRHILLS STATE:FL ZIP:33541 COUNTY:PASCO ACCOUNT#.909DRHFL BUILDER:DR HORTON SUBDIVISION:SILVERADO COMMUNITY:39163 PLAN:NDP 12/12/2016 PROGRAM:HERS1100% TESTER:EFL IECC:2009 CLIMATE ZONE: PROPERTY OWNER: PROPERTY ADDRESS:6526 WAGON TRAIL ST,ZEPHYRHILLS,FL 33541 TEST:BLOWER DOOR RESULT: PASS TESTER:James Payne DATE:07/12/2018 CORRECTION BUILDER RATER TEST NAME NEEDED VERIFIED VERIFIED WA 5.1 Attic Access Panel(fully gasketed and insulated) 5.2 Attie drop-down Stair(fully gasketed and insulated) 5.4 Recessed Lighting Fixtures(ICAT labeled and sealed to drywall) 5.5 Whole-house Fan(insulated gasketed to the opening 7.3 Fresh air ventilation Installed per program specs Blower Door BUILDING ORIENTATION PROGRAM CODE PROGRAM CODE VOLUME CU.FT) VOLUME CU.FT) SHELL SQ. SHELL SO. WA 21,580 0 0 PROGRAM, CODE PROGRAM CODE PROGRAM CODE CFM 50 CFM 50 ACH 50 ACH 50 %of Shell %of Shell BD Target 0 12.518 7 BD Actual 1.931 5.37 Meter# Room Pressure Test Mat Bdrm 0 Bdnn 2 0 Bdr 13 0 Bdrm 4 0 Bdrm 5 1 0 Rm 1 0 Rm 2 0 Rm3l 0 1 Other 0 CO Detectors Energy Star QualifiedAppliances? Efficient Lighting Package? 60 or>Of Hardwhed Lights Must Be CFL Or LED Low Flow Faucets,Toilets eta? Programmable Thermostat? CeAffied Green Progmm Level Requires Visual Inspection Mechanical System Item Location Manufacturer Name Model#1 Model82 Model#3 Model#4 SYSTEM 1 WATER HEATER SYSTEM 2 WATER HEATER SYSTEM 3 WATER HEATER SYSTEM 4 WATER HEATER SYSTEMI FURNACE SYSTEM 1 HVAC OUTDOOR OUTSIDE UNIT SYSTEMI HVAC INDOOR COIL SYSTEMI HVACAHU (HEAT INTERIOR PUMP) SYSTEM FURNACE SYSTEM HVAC OUTDOOR UNIT SYSTEM 2 HVAC INDOOR COIL SYSTEM 2 HVAC AHU (HEAT PUMP) SYSTEM FURNACE SYSTEM HVAC OUTDOOR UNIT SYSTEM 3 HVAC INDOOR COIL SYSTEM 3 HVAC AHU (HEAT PUMP) SYSTEM FURNACE SYSTEM HVAC OUTDOOR UNIT SYSTEM 4 HVAC INDOOR COIL SYSTEM 4 HVAC AHU (HEAT PUMP) BUILDING SPECIFICATIONS BUILDING CHARACTERISTICS ASUESIGN-VALUES AS BUILT-VALUES COMMMENT #OF BEDROOMS(REM) NA NA CEILING FLAT(REM) NA NA SEALED ATTIC(REM) NA NA VAULTED CEILING(REM) NA NA FOUNDATION WALLS(REM) NA NA EXPOSED FLOOR(REM) NA NA ABOVE GRADE WALLS(REM) NA NA DUCT SUPPLY R-VALUE(REM) NA NA DUCT RETURN R-VALUE(REM) NA NA PROGRAMMABLE THERMOSTATS(PRIF) WATER HEATER TYPE(PRIF) WATER HEATER FUEL TYPE(PRIF) TEST:BLOWER DOOR RESULT:PASS TESTER:James Payne DATE:07/122018 BUILDING SPECIFICATIONS BUILDING CHARACTERISTICS ASDESIGN-VALUES AS BUILT-VALUES COMMMENT WATER HEATER SIZE, EFFICIENCY& LOCATION (PRIF) INFILTRATION(HOUSE LKG)ACH(REM) NA Htg:5.37 Clg:5.37 ACH @ 50 Pascals FRESH AIR VENTILATION TYPE(PRIF) VENTILATION FAN MANUFACTURER(REM) NA NA VENTILATION FAN MODEL#(REM) NA NA VENTILATION FLOW REQUIRED(REM) NA NA VENTILATION EQUIP.RATED CFM(REM) NA NA VENTILATION#OF FANS(REM) NA NA VENTILATION TIME-HRS/DAY SPECIFIED(REM) NA NA VENTILATION TIME SET BY HVAC CONTRACTOR- MINUTES PER HOUR(PRIF) FRESH AIR VENTILATION FAN WATTS(REM) NA NA MEASURED FAN WATTS OR PER MANUFACTURER'S SPEC'S(PRIF) INTERIOR%OFCFUS(PRIF) INTERIOR%OF PIN-BASED(PRIF) EXTERIOR FIXTURES(%)(PRIF) GARAGE FIXTURES(%)(PRIF) DISHWASHER(PRIF) REFRIGERATOR(PRIF) FOUNDATION TYPE(PRIF) SLAB TYPE(PRIF) SLAB AREA(PRIF) SLAB DEPTH(PRIF) SLAB FULL PERIMETER(PRIF) SLAB GRADE(PRIF) FLOW RING(PRIF) HEATING(REM) NA NA COOLING(REM) NA NA AIR-SOURCE HP(REM) NA NA WATER HEATING(REM) NA NA TEST:DUCT BLASTER RESULT: PASS TESTER:James Payne DATE:07/122018 TOTAL CONDITIONED FLOOR AREA 0 2,605 (CFA SQ FT) DUCT LEAKAGE TO OUTSIDE%TARGET 0.00% 3,00% TOTAL DUCT LEAKAGE%TARGET 0.00% 0.00% SYSTEM 1 SQ FT.SERVED(CFA) 0 2.606 POST CONSTRUCTION SYSTEM 1 DUCT LEAKAGE TO OUTSIDE D 78 SYSTEM 1 DUCT LEAKAGE TO OUTSIDE 20 SYSTEM 1 DUCT LEAKAGE TO OUTSIDE Infinity% 0.77 (CFM25)TARGET (CFM25)ACTUAL (%OF CFA)ACTUAL SYSTEM 1 TOTAL DUCT LEAKAGE 0 0 SYSTEM 1 TOTAL DUCT LEAKAGE SYSTEM 1 TOTAL DUCT LEAKAGE(1/6 OF NaN% 0.00% (CFM25)TARGET (CFM25)ACTUAL CFA)ACTUAL SYSTEM 2 SQ FT.SERVED(CFA) 0 0 SYSTEM 2 DUCT LEAKAGE TO OUTSIDE 0 0 SYSTEM 2 DUCT LEAKAGE TO OUTSIDE SYSTEM 2 DUCT LEAKAGE TO OUTSIDE (CFM25)TARGET (CFM25)ACTUAL (%OF CFA)ACTUAL SYSTEM 2 TOTAL DUCT LEAKAGE SYSTEM 2 TOTAL DUCT LEAKAGE SYSTEM 2 TOTAL DUCT LEAKAGE(DA OF (CFM25)TARGET 0 0 (CFM25)ACTUAL CFA)ACTUAL SYSTEM 3 SQ FT.SERVED(CFA) 0 0 SYSTEM 3 DUCT LEAKAGE TO OUTSIDE SYSTEM 3 DUCT LEAKAGE TO OUTSIDE _ SYSTEM 3 DUCT LEAKAGE TO OUTSIDE _ (CFM25)TARGET - 0 0 (CFM25)ACTUAL (90 OF CFA)ACTUAL SYSTEM 3 TOTAL DUCT LEAKAGE SYSTEM 3 TOTAL DUCT LEAKAGE SYSTEM 3 TOTAL DUCT LEAKAGE(91OF (CFM25)TARGET 0 0 (CFM25)ACTUAL CFA)ACTUAL SYSTEM 4 SQ FT.SERVED(CFA) 0 0 SYSTEM 4 DUCT LEAKAGE TO OUTSIDE SYSTEM 4 DUCT LEAKAGE TO OUTSIDE SYSTEM 4 DUCT LEAKAGE TO OUTSIDE (CFM25)TARGET 0 0 (CFM25)ACTUAL (%OF CFA)ACTUAL TEST:DUCT BLASTER RESULT: PASS_TESTER:'Jamas Payne DATE:07/12/2018 9 � ' SYSTEM 4 TOTAL DUCT LEAKAGE SYSTEM 4 TOTAL DUCT LEAKAGE SYSTEM 4 TOTAL DUCT LEAKAGE(%OF (CFM25)TARGET 0 0 = (CFM25)ACTUAL CFA)ACTUAL BUILDING SPECIFICATIONS BUILDING CHARACTERISTICS" DESIGN-VALUES = ASBUILT-VALUES " _ COMMMENT DUCT LEAKAGE TO OUTSIDE(REM) NA - 0.008 CFM251 CFA TOTAL DUCT LEAKAGE(REM) NA NA FLOW RING(PRIF) FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Envelope Leakage Test Report Prescriptive and Performance Method Project Name: SILVERADO Builder Name: D R HORTON Street: 6526 Wagon Trail St Permit Office: City,State,Zip: Zephyrhills,FL 33541 Permit Number: Design Location: 6526 Wagon Trail St(Lot 15) Jurisdiction: Cond.Floor Area: 2605 Cond.Volume: 21580 Envelope Leakage Test Results Leakage Characteristics Regression Data: C: n: R: CFM(50): 1931 Single or Multi Point Test Data ELA: 106 HOUSE PRESSURE FLOW: EgLA: 251 1 50 Pa 1931 cfm ACH: 5.37 2 0 Pa 0 cfm SLA: .04 3 0 Pa 0 cfm ACH(50)': 5.37 4 0 Pa 0 cfm .For prescriptive projects,tested leakage must be<=7 5 0 Pa 0 cfm ACH(50). For performance projects, tested leakage must be<=the ACH(50)shown on Form R405-2014 6 Pa cfm for this project. R402.4.1.2 Testing.The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zones 1 and 2.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statutes or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration 3.Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. I hereby certify that the above envelope leakage performance results demonstrate compliance with Florida Energy Code requirements in accordance with Section R402.4.1.2. Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7), Florida Statutes p4THEST'tTZ-. or individuals licensed as set forth in Section 489.105 3 or I or an approved third party.A written report of the results of the test shall be signed by the third party conducting the test and provided to Digitally signed by James Payne tii4 Date:2018.07.12 21:24:55 EDT the code official. m Payne,O=TopBuild Hoe Services, Home Services,OU, G'pD WE{SLJ EMAILADD RESS=james.payne Signature: @topbuild.com,C=US Printed Name: James Payne BUILDING OFFICIAL: Date. 0 7/1 212 0 1 8 DATE: Thank you for allowing TopBuild the opportunity to provide the above services for you.Please feel free to contact me with any questions. 10/25/2017 386305 C RESNET Home Energy Rating Standard Disclosure For home located at: Lot 15 6526 Wagon Trail St,Zephyrhills,FL 33541 City: Zephyrhills State: FL 1. F-x]The Rater or Rater's employer is receiving a fee for providing the rating on this home. 2. ❑X In addition to the rating,the Rater or Rater's employer has also provided the following consulting services for this home. A. Mechanical system design B. Moisture control or indoor air quality consulting C. Performance testing and/or commissioning other than required for the rating itself X D. Training for sales or construction personnel E. Other(specify below) 3. 1-1 The Rater or Rater's employer is: A. The seller of this home or their agent B. The mortgagor for some portion of the financial payments on this home C. An employee,contractor or consultant of the electric and/or natural gas utility serving this home 4. 1-1 The Rater or Rater's employer is a supplier or installer of products,which may include: Installed in this home by: OR is in the business of: HVAC Systems Rater Employer Rater Employer Thermal Insulation Systems Rater Employer Rater Employer Air sealing of envelope or duct systems Rater Employer Rater Employer Windows or window shading systems Rater Employer Rater Employer Energy efficient appliances Rater Employer Rater Employer Construction(builder,developer,construction contractor,etc.) Rater Employer Rater Employer Other(specify below): Rater H Employer Rater Employer I attest that the above information is true and correct to the best of my knowledge.As a Rater or Rating Provider I abide by the rating quality control provisions of the Mortgage Industry National Home Energy Rating Standard as set forth by the Residential Energy Services Network (RESNET).The national rating quality control provisions of the rating standard are contained in Chapter One 4.C.8.of the standard and are posted at http://resnet.us/standards/RESNET Mortgage_Industry_National_HERS_Standards.pdf.The Home Energy Rating Standard Disclosure for this homeis available from the rating provider. James Payne RESNET#:K21Q1N Rater's Printed Name Certification# July 12,2018 Rater's Signature Date RESNET Form 0300-2 REM/Rate-Residential Energy Analysis and Rating Software v14.5.1 This information does not constitute any warranty of energy cost or savings. ©1985-2014 Architectural Energy Corporation,Boulder,Colorado. 385305