Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
18-19465
CITY OF ZEPHYRHILLS j 5335-8TH STREET (813)780-0020 1946,5 BUIf DING PERMIT SINGLE FAMILY RESIDENTIAL PERMIT INFORMATION LOCATION INFORMATION Permit#:19465 Issued: 3/26/2018 Address: 6581 WAGON TRAIL ST Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 294,294.45 Total Fees: 11,318.19 Subdivision: SILVERADO Amount Paid: 11,318.19 Date Paid: 3/26/2018 Parcel Number: 05-26-21-0080-00600-0290 CONTRACTOR INFORMATION OWNER INFORMATION Name: DR HORTON INC Name: D R HORTON INC Addr: 12602 TELECOM DR Address: 12602 TELECOM DR TAMPA, FL. 33637 TEMPLE TERRACE FL 33637-0935 Phone: Lic: Phone: 813-549-1968 Work Desc: CONSTRUCT SINGLE FAMILY 2,213 SQ FT APPLICATION FEES PLUMBING FEE 140.70 ELECTRICAL FEE 211.05 MECHANICAL FEE 98.49 BUILDING FEE 1,036.76 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 SCHOOL IMPACT FEE-sfr/100% 4,828.00 SCHOOL IMPACT FEE-sfr/1% 48.28 PARK FEES SF 769.56 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32 Inspections Required FOOTER 2ND ROUGH PLUMB Misc INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing, consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications and Must Accompany Application. All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRACTORS SIGNATURE PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER PASCO COUNTY, FLORIDA Permit No. _ Date Permitted 3-24-fig Builder Name/Owner Name c Rm_ZY " -- Control#' . County Parcel No. 65 2 -2_(_1 050--()o6(2 7 - 02-T 0 SubDiv: Ue'Jo _ r, Address/Location 405 t i, Classification/Type of Use z 2 3 r• TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: Z 2 t3 G. - Exempt [].Yes ❑ No How Determined Impact Fee Amounts. 31 &32, Zone No. TAM C y" SCHOOL IMPACT FEE j r? Account (056) Single-Family Detached House Amount $ _ , 6 Z , 26 r;._. (057)' Mobile Home (058) Other Residential 123) Collection Fee Exempt [�Yes ❑No How Determined PARKS AND RECREATION FEE Land Account Land Credit Land Total Recreation Account Recreation Credit -Recreation Total Zone TOTAL AMOUNT $ (Pj�, Exempt ❑Yes ❑ No How Determined LIBRARY FEE i` Land Account Land Credit Land Total 5,. . Facility Account Facility Credit Facility Total Exempt ❑Yes ❑No How Determined Total Amour RESOURCE FEE ERU TOTAL AMOUNT Prepared By / - Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE r. BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE•OF PASCO COUNTY f` .< Acknowledgement below does not Imply acceptance of concurrence,but simply receipt of•a copy of this form,placing the bullding permit owner on notice of this assessment and the conditions of payment for same. DATE RECEIVED BY RECEIPT NO. DATE BY City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: Date Received: Site: Permit Type: Approved w/no comments:❑ Approved w/the below comments: Denied w/the below comments: ❑ This comment sheet h Il be kept with the permit and/or plans. J r/ Kalvin S ter—Plans Examiner , Date Contractor and/or Homeowner (Required when comments are present) PASCO COUNTY r I DEVELOPMENT SERVICES PA-S.C. `` 8731 Citizens Drive Date:7/10/2018 COUNTY.::.L0�2I1�f1, New Port Richey,FL 34654 OPEN aRac:}s,�udcl,�r Ptnclti. 27-847-2411 Receipt M 1774496 FEE DESCRIPTION ACCOUNT CODE UNITS INVOICE# FEE AMOUNT PAID RECEIPT# DATE Impact Fee Residential Solid 24503100-329010 31.60 1362332 $31.60 $31.60 1774496 7/10/18 Waste Single Family TOTALS: $31.60 $31.60 Receipt# Paid By Check# CC Auth# Cashier ID Workstation Receipt Date Amt Paid 1774496 Check 767926 540 BCCCP06W 07/10/2018 $31.60 Total Payments: $31.60 Pavor Address Phone D R Horton 1341 Horton Circle Arlington TX 76011 Comments: City of Zephyrhilts,SolidnWaste �( AddE69 on T Street Parcel:05 26 210080 00600 0290 While you will be paying your blll wlth Pasco County Development Services,the full amount of the credit card ore-check fees,NOT shown above,Is collected by First Billing payment services. MyReports/reports//PASCOPROD/PASCO/ReceiptPOS V6,rpt 7/10/2018 Page 1 of 1 'CITY OF / / " BUILDING ZEPHYAHILLS DEPARTMENT A NOTICE OFADDITION OR CORRECTION D • NOT REMOVE ADDRESS DATE PERMIT f CIA 4r4,, !� THIS JOB HAS NOT BEEN COMPLETED. The following additions or corrections shall be made before the job will be accepted. It is unlawful for any Carpenter,Contractor,Builder,or other persons,to AFTER CORRECTIONS ARE MADE CALL cover or cause to be covered,any part of the work with flooring,lath,earth 780-0020 FOR RE-INSP TION or other material,until the proper inspector has had ample time to approve C/v the installation. OFFICE HOURS 7:30 AM-5 PM MON.-FRI. INSPECTOR 11111111111 loll 1111111111 2018043933 -7-- Rept: 1940178 Rec: 10.00 DSc 0.09 IT: 0.00 03/15/2o18 eRecording Permit No. Parcel ID NOTICE OF COMMENCEMENT State offs-ter I County of ezS—W* THE UNDERSIGNED hereby gives notice that Improvement will be made to certain real property,and in accordance with Chapter 713,Florida Statutes, the following information Is provided in this Notice of Commencement. 1. Description of Property: Parcel Identification No.i A+1 . LAIL bl Street Address: 2. General Description of Improvement .—J�RSx -2EAC( lyaM'11 IS/ fiii`6�Lichopie-c- 3. Owner Information or Lessee information if the Lessee contracted for the improvement: N;a—me ZL I-e-rin/IIA -D r 10 Address city 1 State Interest in Property: Name of Fee Simple Titleholder (If different from Owner listed above) Address city State 4. Contractor, Hor4of) :2e -L1601 amp .i(eczm— -Dr ::[at 0A OCL Address city— State Contractor's Telephone No.: 5. Surety: A7 ill a Name' Address city State Amount of Bond: Telephone No.: 6. Lender. A) Narne Address city State Lender's Telephone No.: 7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)(7),Florida Statutes: Name 60 0 JQ, Address State Telephone Number of Designated Person: 8. In addition to himself,the owner designates of toreceive a copy of the Llenoes Notice as provided in Section 713.13(1)(b),Florida Statutes. Telephone Number of Person or Entity Designated by Owner: 9. Expiration date of Notice of Commencement(the expiration date may not be before the completion of construction and final payment to the contractor,but will be one year from the date of recording unless a different date is specified): WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY- A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalty of perjury,I declare that I have read the foregoing notice of commencement and that the facts stated therein are true to the best of my knowledge and belief. STATE OF FLORIDA COUNTY OF PASCO Signa(ure of Owner or Lessee,or Owner's or Lessee's Authorized Officer7Dfrector/Partner/Manager —All —D Ive,4 v. — , ti ty. Signatory's Title/Office The foregoing instrument was acknowledged before me this day of 20-(&by i v 1 i G V) eye;f(Z-/ (type of authority,e.g.,officer,trustee,attorney in fact)for -'Ll".d 0 Eill Ill (name or palty on b h I� f whom in�IrNment was executed). T Personally Known[9 OR Produced Identification❑ Notary Signatul-111- (1,,'71:X Type of Identification Produced Name(Print) Notary Public State of PAULA S.O'NEILPh.D.PASCO CLERK a COMPTROLLER Michelle Florida I OR Bx 9593 PG 102r3 4% Moyes 03/15/2018 04:22 PH I Of A IY Commission GG 05732 N'Qj L NO' x0res 12/1 wpdata/bes/noticecommencement_pcOS3048 DR Horton-6581 Wagon Trail St-2,213 sq ft- o umn Es SQ. FEET PRICE MAIN OR LIVING: 2,213 $ 112.65 OTHER AREA UNDER ROOF: - $ - OTHER: - $ - VALUATION $ 249,294.45 FEE SHEET $ 938.00 ADDRESS $ 40.00 DRIVEWAYJ $ 40.00 BUILDING: $ 1,036.76 ELECTRICAL: $ 211.05 PLUMBING: $ 140.70 MECHANICAL: $ 98.49 SUB-TOTAL $ 1,487.00 TOTAL $ 1,487.00 SEWER: WATER: - IRRIGATION: $ - TOTAL: $ - WATER METER: IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: $ INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35, SUB-TOTAL $ 2,040.35 PARK IMPACT FEES $ 769.56 SIF'S: $ 4,828.00 100.0% $ 4,828.00 1.0% $ 48.28 TOTAL: $ 4,876.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 11,318.19 D.R. Horton-6581 Wagon Trail.St-2213 sq ft o umn 13 SO. FEET PRICE MAIN OR LIVING: 2,213 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 249,294.45 FEE SHEET $ 938.00 ADDRESS $ 40.00 DRIVEWAY $ 40.00 BUILDING: $ 1,036.76 ELECTRICAL: $ 211.05 PLUMBING: $ 140.70 MECHANICAL: $ 98.49 SUB-TOTAL $ 1,487.00 TOTAL $ 1,487.00 SEWER: $ 2,01 .00 WATER: $ 64 .00 IRRIGATION: $ TOTAL: $ 2,65 00 WATER METER: $ 47 . IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 5,165.13 PARK IMPACT FEES $ 769.56 SIF'S: :$ 4,828.00 100.0% $ 4,828.00 1.0% $ 48.28 TOTAL: $ 4,876,28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 14,442.97 813-780-0020 City of Zephyrhilis,Permit Application Fax-813aa0-0021 Building Department I07. Aa"► Date Fjoceived Phone Contact for Permitting -- T-r'r1Ti'T"T" i 4 Owner's Name Owner Phone Number V1 L �t• !J ,• .�K Owner's Address (��>Q�,Z�!e'�� '""' J)°�' Tc.ry^1��„3� � ,owner Phone Number Fee Simple Titleholder Nam. Owner Phone Number �- Fee Simple Titleholder Address JOB ADDRESS `j l 5 u LOT# SUBDIVISION t 3' T' PARCEL iD# •� `�. c / �" ] " �G� (OBTAINED FROM PROPERTY TAX NOTICE) ; WORK PROPOSED I TR 8 � REPAIR � SIGN 0 0 DEMOLISH , NSTALL • PROPOSED USE �"` SFR 0 COMM . OTHER TYPE OF CONSTRUCTION BLOCK FRAME STEEL 0 DESCRIPTION OF WORK Z74 i BUILDING SiZE SO FOOTAGE '� S� ZZ HEIGHT' '�� r'r'r"f-t-r-r-r-r-rrrrrr-r-v-r, p-r'r-a�-�-s�e- =BUILDING $ fi VALUATION OF TOTAL CONSTRUCTION ELECTRICAL $, AMP SERVICE PROGRESS ENERGY W.R.E.C. PLUMBING $ =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION06=6 ! =GAS ROOFING SPECIALTY OTHER FINISHED FLOOR ELEVATIONS i FLOOD ZONE AREA DYES NO •�-s-�-�-A-#-G--i-�^I-�-a-C-G-i-h--G-li-�-1-.F-i-64fr••6-;,-�-A-�-��a-;;°�-�-1�-8-8-I-8-6-6-�-6-1-;r- °�.�-E.-I..�..i•�- BUILDER _ COMPANY • SIGNATURE �" REGISTERED Y/ N FEE CURREN Address 1r� G7r )� �1�<YS.r+7 ,� !^ License# ..ELECTRICIAN ( r i-2�^� ,f ,� COMPANY <:71 In 1:09.-rO,0 SIGNATURE REGISTERED Y/ N FEE CURREN I Y/N Address �t +��°ts ,�' r ., License# PLUMI3ER •fr-�d�T t`--, COMPANY .SIGNATURE REGISTERED Y/ N FEE CURREN Y/N ,r� Address, {� Iva ��/�/t� f �i •P,,z License# ?rc o el, l MECHANICAL r „ ll ��%' r i 7 SIGNATURE t.' '-� ' ''� --_'--COMPANY �A� ��� � A ��r REGISTERED. Yr"/ N FEE CURREN Y f 14 • ' Address ✓ter'--7iV2 1, -x0.^ x� t a � 1r.Ur,L`�` rj License#OTHER. F _--- COMPANY SIGNATURE �r �^ REGISTERED Y j N FEE CURREN Y j N Address /,a,9U �' ��u License# -------� r 4 iiliiillllllllllllllilllllllilll ! ! llBill ! ! IIl1ii11il11. 1lillllll ! ! 1 RESIDENTIAL Attach (2) Plot Plans; (2)sets of Building Plans; (1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal.date. Required onsite,Construction Plans,Stormwater Plans w/Silt•Fence installed,-, Sanitary Facilities&1 dumpster,Site Work•Permit for subdivisionsjiarge projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page; (1)set of Energy Forms. R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&•1 dumpster.Site Work Permit for ail new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. "PROPERTY-SURVEY required for all NEW construction. Directions: r cti o s:4-i--b-b-i.i-1--i-i--i-i=i-3.-i-G-i--d-i...II--d-O�{.-6..6-C�l�B-B-A-6.-6--9..a..�-Il-➢--B-R-9.-9.�8-8-:rta-&.8- ,�C�-dS-4=-$�9-D.�..Fs..6.oE�. Directions; Fill out application completely. Owner 4 Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500) Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner autnoriz ng same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs jf shingles • Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW . . . . . . . , NOTICE OF DEED RESTRICTIONS: The undersigned understands that this pmMn | nlaybasube dead"' ^ n�� which may be more reoth*t�ethan Coun�' regu�bnnn. The undem|gnedasa«nn^^^naapom�bU nnp|i�nn�*u�uuna� oppUuab|edeed naathcbVno. ~~ `� '"' compliance ' UNLICENSED CONTRACTORS AND CONTRACTOR ' RESPONSIBILITIES:'|f the owner hsm hi�o—d� aco ntractor or contractors unde�akework, they may bo required10 be licensed in accordance with *t��- and local regulations. " "e contractor ia not iireneedoarequired by law, oththe ownerand uonbauto' may becited fnr - misdemeanor `'o|a^'~ 'unUer state law. If the owner or intended:contractor are uncertain as to.what licensing mqu|-pm�� may ��� �r�eintended work, they are ad�sedto contact the Pasco County Building/ m eoUm . Division—Licensing Seot�nat727'847- 8OOB. Furthermore, � dle owner has hired u contractor or contractors,. he is advised to have the contractor(s) sign portions of the "contractor Block" ofthis app.|ication for which they will be responsible. If you, as the owner a| as nontraoto� that may bean indication that hoie not propadylicensed and is not en�Uadto permitting privileges.in Pasco - ` County. ^ TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned.understands that Transportation Impact Fees and Recourse Recovery Fees may apply tothe construction of new buUd|ngs, change of use in existing bu||dingo. or expansion of existing bu||d|nge, as specified in Pasco County Ordinance number 89'07 and 90-07. as amended. The undersigned also,underatands, that such feas, as may be duo, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power nalease'. |f the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pa000-CnuntyVVnter/Savvar Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW'(Chapter7i3, Florida Statutes, asammended): |f valuation of Work is $2.SOU.bOormore, | certify that |, the applicant, have been provided with o copy of the "Florida Construction, Lien Law—Homeowner's Protection Guide" prepared by the Florida Department ofAgriuuUUre.and Consumer Affairs. If the applicant is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver itto the''mwna/' prior to commencement � , CONTFQ\CTdR`SIOVVNERIS /\FF|DAVlT: I certify that all the information in this application Is accurate and that all work will be done in-compliance with all applicable laws regu|dting construction, zoning knd. |and development. Application is ` hereby made to obtain a permit to do work and installation as indicated. | certify that no work or installation has commenced priorto issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes; zoning regu|abons, and land development regulations.in the jurisdiction. \ also certify that | understand that the regulations nf'cther government aQonC|eu may apply to the intended vvork. And that it is my responsibility identify what actions I must taketobaincompliance. Such agencies include but are not limited tot - DepertmeOt,ofEnvi[onmonta| Protection-Cypress Bayheads. Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cvonaao Bayheada, Wetland Areas' Altering Watercourses. . ' Army Corpa�of Engineers-Seawalls, [}ooka. Navigable Waterways. ' - Department of Health & Rehabilitative Services/Environmental Health Unh-VVa|hs, VVaatavva±er Treatment,� Septic Tanks. _ ' UG-Environmente\ protectonAgonoy-Aobastooabstement. - Federal Aviation Authority-Runways. | understand that the following restrictions apply to the use offill: ' Use of fill ie not allowed in Flood Zone"V" unless expressly pernittud` If the' fill material is to be used in Flood Zone "A". it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by 8 professional engineer ' licensed by the State OfFlorida. / ' If the h8 nnataha\ is to be used in Flood Zone "N' in connection with a permitted building using stem wall oonstrpotion. | oe�\fv that fU\wUIbe used only tofU|the area vvhhinthe sden)voaU. ' If fill material is to be used in any area, | certify. that use of such fill will not adversely affect adjacent ` properties. If use of fill is fou nd-to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one M\ acre which are elevated by fill, an engineered drainage plan is. requ|r*ad. _ |f | amthe AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions bet forth in this affidavit prior to commencing construction. | understand that a separate permit may be.required for electrical work, � plumbing, oigns, wells, pools, air conditioning, Qae' or other installations not specifically included in the application. /\ permit issued shall be construed to be a license to proceed with-the work and not as authority to violate, cancel, alter, or sei aside any provisions of the technical codes, nor shall issuance .of a permit prevent the Building Official from thereafter requiring aoonectionof errors-in plans, construction urv\o\sdonaof any codes. Every pernnitissued ahaU become invalid unless the work authorized by such permit is onnnrnanuod within six months of permit iosuonce, or if work authorized'by the permit is suspended or abandoned for a period,,of six (6) months after the time the Work is commenced. An extension may be requested, in-writing, from the'Bu||ding Official for a period not to exceed ninety (QO) days and will demonstrate ` justifiable cause for the extension, \f work ceases for ninety K)O\ consecutive days,the job�a considered abandoned. WARNING TO OWNER: YOUR FAILURE TORECORD A NOTICE OF COMMENCEMENT MAY RESULT / YOUF�: PA�N��TV0I��E F[�BI80PROVEK8ENTST YOURF '- ��� .�_ - _''--. -_''_-_'FLORIDA JURAT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR:NOTICE'OF COMMENCEMENT. ` . . _ OWNER OR AGENT Subscribed 4r�d sw nto or affirmed)before me this Subscribed and sworn to(or affirmed)before me thisCONTRACTOR bv or ND by ". has/have vmuucvu Who is/are ppmoneo known to me or has/have as�on�fio��nIdentification.' produced. mo^uncatmn . ' ' ' - ~ ' y_ -Notary Public oomm�xmnNv .'Commission ` « oomm�e�nNo ' . '~..~of Notary typed,printed or stamped Name mNotary typed,printed orstamped NotarY Public ` kya"407 lily COMMISsi 8 057321 12121 0 S ing e Farri* Y Dwelling:. :. . planComments Review . l: F.F.E.; shall be a minimum of 8" above,the road.elevation;and an engirieered.site plan. : 2.. Lots shall be graded.to-comply with R401.3 of the F.B.C. .: 3. Compaction:test required if 24 or more.of fill dirt is.brought.in:at an:y one place: 4. :Tie in.survey required before pouring concrete. 5. Driveways:require a R.O.W. use permit.: All sides of driveway.thru the sidewalk shall-have. . expansion material:. . . 6. Ail.setbacks shall be met.: .' 7.: :All property'markers shall be,uncove'red and marked.at time"of first inspection: 8 .All A.D.A. requirements shall be met..'. 9. No:electric,plumbing,mechanical;"or framing shall be covered without an inspection and approval first..: 10. All Garages shall:comply.with.section R302.6 of the F.B:C;:(Fire S:eparation). 11.Appliances shall not:be installed in:a locationwhere subject to it chanical darnage unless..." protected by approved barriers. M303.4 of.'the F.B.C. 12. Water,heaters shall corriply:with section:P607.3 of.the F:B.C: 13. Foundation supports for,A/C.units shall be raised at least 3'' above finished grade,. M1308.1. 14. Return aif in all bedrooms.-F.B.C. M1620.4 15: Smoke detectors'are.to be installed:in accordance with:R31'3.1 of ihe:F.B.C. .16::All glazing requirements are..to be in accordance with R308.4.of the.ERE. 17. All means.of egress are to be in accordance-with R3 I L of the R.B.C. 18. `.`Green gypsum.board'' shall not b 'used:as.a backer.in:showers:or tubs. R702.4:2 F.B.C. 19. Combination-fypeAFCI�breakers are.required.at all.locations requiring an AFCI,type breaker: 20. Carbon monoxide alarms:will be required in new-construction that uses fossil-biiming.heating :or appliances or an attached garage.. They shall be,installed in accordance with.the F.B.C. 21. All plumbing, mechani-al,.and electrical shall be'sepatate from unit to:unit: This includes all. .' underground plumbing and electric: M All 2008.N.E.C. Codes.will be enforced. 23.Tamper-Resistant Receptacles in accordance with 406.11 of the 2008 NRC 24::In accordance with the Land.Development.Code; lots.shall be sodded before final of least l 0 feet:around the structure: 25. A.copy of the ever y cacls shall be with pern:itat all ti�raes. :. '26"Copy oflinal insulation repbrt shall bevrbvided with.permit.before final F.F.E.-Finished Floor.Elevation F.B.C=Florida Building Code 5�':Edition R,O.W.-Right.of Way A.D.A.-Americans with Disabilities Act N.E.C.-National Electric.Code (2008)- PLOT PLAN DESCRIPTION:(AS FURNISHED) LOT 29, BLOCK 6, SILVERADO RANCH SUBDIVISION PHASE 6, 8 & 9A AS RECORDED IN PLAT BOOK 75, PAGE(S) 75-80, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. PT LOT 30 o; BLOCK 6 I Iz S87-24'28"E 1" = 3°' GRA 124.86' s GRAPHIC SCALE IN 0 15 30 >_ p I 48.0' Z o I m l, O Lf) I o;' 55.7' 21.2' w ' J o.w I 0;o m 55.67' U}a I co aiw a. o a I O I lnQ^ w I N Y oO1 lin I o �Q .J 0 Y L1J R I V ti pp 0 0 0 , •o LLJ'S ISO I ~ QwIN i i tn�I2� o . .... 20.s' LiltL_ =O0 N = I Q J �z asm�� a • I �Or Um J m mQ n n OIOz=F 8.0 N=3 2 5 I °o az i> 21.2'O. - coo OL tow Z ' o n I N87'24 28 W 124.86' N872428=w d I 30.00' 3 z I INm LOT 28 BLOCK 6 I nlyg I i I ON LOT CALCULATIONS LOT = 6,867 SQ. FT. LIVING AREA = 1,751 SQ. FT. GARAGE = 426 SQ. FT. PC ENTRY = 36 SQ. FT. LANAI = 0 SQ. FT. PATIO = 80 SQ. FT. DRIVEWAY = 339 SQ. FT. A/C PAD = 12 SQ. FT. WALKWAY = 25 SQ. FT. IMPERVIOUS = 39% = 2669 SQ. FT. SOD = 4,198 SQ. FT. PREPARED FOR: OFF LOT CALCULATIONS RIGHT OF WAY = 715 SQ. FT. �ji_*HOWN-r., DRIVE APRON = 152 SQ. FT. Hr.� PUBLIC S/W = 275 SQ. FT. ftf✓Nl� jGdt!Gi'3 SOD = 288 SQ. FT. TOTALS BUILDING SETBACKS AREA- = 7,582 SQ. FT. DRIVEWAY = 491 SQ. FT. FRONT: 20' SIDEWALK = 300 SQ. FT. REAR: 15, SOD = 4,486 SQ. FT. SIDE: 7.5' SIDE STREET: 20' LEGEND: NOTES. — '— ' BUILDING SETBACK LINE PI POINT OF INTERSECTION PC POINT OF CURVATURE 1. ELEVATIONS SHOWN ARE PER LOT GRADING - CENTERUNE PT POINT OF TANGENCY PLANS PROVIDED BY THE CLIENT. — - - — RIGHT OF WAY LINE RP RADIUS POINT 2. ELEVATIONS ARE BASED ON NAVD 1988 XX•XX PROPOSED ELEVATION PRC POINT OF REVERSE CURVATURE PCC POINT OF COMPOUND CURVATURE DATUM. TYP TYPICAL PROPOSED DRAINAGE FLOW CS CONCRETE SLAB THIS PLOT PLAN IS INTENDED FOR PERMITTING PURPOSES . CONCRETE CALCULATED (P) PER PLAT ONLY. THIS IS NOT INTENDED FOR THE CONSTRUCTION OF (PB C PLAT BOOK THE PROPOSED HOUSE. REFER TO HOUSE PLAN AND A/C AIR CONDITIONER PGs PAGES OPTION LIST FOR CONSTRUCTION. ALL BUILDING SET BACK s/W SIDEWALK SO. FT. SQUARE.FEET LINES SHOWN HEREON IS PER DATA FURNISHED BY CLIENT F.E.M.A. FEDERAL EMERGENCY MANAGEMENT AGENCY AND IS FOR INFORMATIONAL PURPOSES ONLY. F.I.R.M. FLOOD INSURANCE RATE MAP NAVD NORTH AMERICAN VERTICAL DATUM THIS IS NOT A SURVEY D&UE DRAINAGE k UTILITY EASEMEN DATUM THIS IS A PLOT PLAN ONLY UEE UTILITY EASEMENT PRIVATE DRAINAGE EASEMENT (PUBLIC) PLO OP NOfi9` SURVEYOR NOTES: I HAVE EXAMINED THE F.I.R.M. MAP NO. 12101CO288F, - 1. . THE SURVEYOR HAS NOT-ABSTRACTED THE DATED SEPTEMBER 26. 2014. AND FOUND THE SUBJECT PROPERTY LAND SHOWN HEREON FOR EASEMENTS, RIGHT APPEARS TO LIE IN ZONE'X', AREAS DETERMINED TO BE OUTSIDE THE OF WAY, RESTRICTIONS OF RECORD WHICH 0.2%ANNUAL CHANCE FLOODPLAIN. THE SURVEYOR MAKES NO MAY AFFECT THE TITLE OR USE OF THE LAND. GUARANTEES AS TO THE ABOVE INFORMATION. PLEASE CONTACT THE LOCAL F.E.M.A. AGENT FOR VERIFICATION. 2. NO UNDERGROUND IMPROVEMENTS HAVE'BEEN BEARING BASIS: LOCATED EXCEPT AS SHOWN. ' BEARINGS SHOWN HEREON ARE BASED ON THE CENTERLINE OF WAGON A5hA 3. NOT VALID WITHOUT THE AUTHENTIC TRAIL STREET BEING s02.35'32'W, PER PLAT. ELECTRONIC SIGNATURE AND THE AUTHENTIC ELECTRONIC SEAL OF A FLORIDA LICENSED REVISED: AMERICAN SURVEYOR AND MAPPER. (FIELD DATE:) S U RV I-Y I N G 1'= 30 FEET w Digitally J.,neswit.1gned by an,Boleman SCALE: ems:',;«•ti'•O,�a DN:cn=lames W Boleman, JB 8 MAPPING INC. '��, ' � ,;`.o Amencan Surveying&Mapping, APPROVED BY. JB 5. CERTIFICATION OF AUTHORIZATION NUMBER Lb#5393 t email=l6aleman@asmcarporate.cam,FOR 3191 MAGUIRE BOULEVARD, SUITE 200 ^:;j•�. �;i` "c=US'- THE JOB NO. 171D73 LOT 29, BLK 6 - ORLANDO. FLORIDA 32803 °joao����° Date:2077.11.7609:73:22-0500 FIRM (401) 426-7979 DRAWN BY: DSB PLOT PLAN 11 13 17 KJW WWW.AMERICANSURVEYINGANDMAPPING.COM JAMES W. BOLEMAN PSM# 6485. DATE 05-26-21-0080-00600-0290 Pasco County Property Appraiser Page 1 of 1 Data Current as Of: Weekly Archive - Saturday, March 17, 2018 Parcel ID 05-26-21-0080-Q0600-0290 (Card: 001 of 001) Classification 007 Vacant Residential Mailing Address ,,<=.Property Value D R HORTON INC Ag Land $0 12602 TELECOM DR Land $24,347 TEMPLE TERRACE FL 33637-0935 Building $0 Physical Address Extra Features $0 6581 WAGON TRAIL STREET ZEPHYRHILLS, FL 33541 $24,347 Just Value Legal Description (First 4 Lines) Assessed (Non-School Amendment 1) $24,347 SILVERADO RANCH SUBDIVISION PHASES 6, 8 &9A PB 75 PG 075 BLOCK 6 Taxable Value $24,347 LOT 29 Jurisdiction City of Zephyrhills T �_ Land Detail (Card: 001 of.001) Line Use DescriptionZoning Units_ IType Price Conditi Value _ 1 0100 SFR _MPUD 6,000.00 SF $4.00 1.00 $24,000 2 0100 SFR MPUD 1 868.00 SF $0.40 1.00 $347 _ Additional Land Information _ Acres 0.16 Tax Area 30SI FEMA _ Residential Code SLVRLPI I Code Ili Building Information - Use 00 - Unimproved (Card: 001 of 001) Unimproved Parcel 00 - Unimproved _ Extra Features (Card: 001 of 001) _ Line Description Year Units u Value No Extra Features Sales History- See All 6 sales Previous Owner: DUNE FL LAND I SUB LLC Month/YearlBook/Page Type _ _ DOR Code Condition Amount 03/2018 9690 / 1274 _ Warranty Deed 05 Vacant Multi-Parcel Sale 05/2017 9535 / 0546 Certificate of Title 05 Vacant Multi-Parcel Sale 11/2016 9462 / 0384 Mineral Rights or Royalty Transfer 05 Vacant Multi-Parcel Sale http://search.pascopa.com/parcel.aspx?parcel=2126050080006000290 3/20/2018 "FORM R405-2014 ' FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Neuville 1751 EEllev D- Builder Name: DR Express Street: ( ,b of � � I �'G t� [" Permit Office: City,State,Zip:l Zeph4 ills, FL,S'�\ Permit Number: (y�� Owner: ��� Jurisdiction: (P 1 0101 Design Location: FL,Tampa County:: Pasco( lorida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1640.9 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul, Exterior R=4.1 1366.40 ft2 _ b.Frame-Wood,Adjacent R=11.0 274.44 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 10.Ceiling Types (1751.0 sgft.) Insulation Area 5. Is this a worst case? No a.Under Attic(Vented) R=30.0 1751.00 ft2 6. Conditioned floor area above grade(ft2) 1751 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11. Ducts R ft2 7. Windows(174.5 sgft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 392 a. U-Factor: Dbl, U=0.34 134.50 ft2 SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.55 40.00 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.34 a.Central Unit 28.6 SEER:14.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 28.6 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 1.110 ft. Area Weighted Average SHGC: 0.317 14.Hot water systems a.Electric Cap:50 gallons 8. Floor Types (1751.0 sgft.) Insulation Area EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1751.00 ft2 b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.100 Total Proposed Modified Loads: 59.60 PASS Total Baseline Loads: 60.20 I hereby certify that the plans and specifications covered by Review of the plans and ''lf Sp,�� this calculation are in compliance with the Florida Energy specifications covered by this 4 _ ;�0 Code. calculation indicates compliance �r, ''� = with the,Florida Energy Code. PREPARED BY: L Before construction is completed 9 _', DATE: n-u-n this building will be inspected for __1� compliance with Section 553.908 I hereby certify that this building, as designed,is in compliance Florida Statutes. with the Florida Energy Code. �D W8"r'�� OWNER/AGENT: Z -BUILDING OFFICIAL: DATE: DATE: //ty y G - Compliance requires.cer:tif!cation by the air handler unit manufacturer that the air handier enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with Section 803 of RESNET Standards,is not greater than 0.060 Qn for whole house. 1 1/1 1/2017 1:32 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Neuville 1751 Elev D Builder Name: DRH Express Street: 6i5ol WDgcn 7rQ tl S�. Permit Office: City,State,Zip:l Zeph ills, FL,3��\ Permit Number: Owner: ✓ pal Jurisdiction: Design Location: FL,Tampa 2 t County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1640.9 sgft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul, Exterior R=4.1 1366.40 ft2 b.Frame-Wood,Adjacent R=11.0 274.44 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types (1751.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1751.00 ft2 6. Conditioned floor area above grade(ft2) 1751 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11. Ducts R ft2 7. Windows(174.5 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 392 a. U-Factor: Dbl,U=0.34 134.50 ft2 SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.55 40.00 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.34 a.Central Unit 28.6 SEER:14.00 c. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 28.6 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 1.110 ft. Area Weighted Average SHGC: 0.317 14.Hot water systems a. Electric Cap:50 gallons 8. Floor Types (1751.0 sqft.) Insulation Area EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1751.00 ft2 b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.100 /'1�7CS Total Proposed Modified Loads: 59.60 PASS Total Baseline Loads: 60.20 1 hereby certify that the plans and specifications covered by Review of the plans and sr41 ' this calculation are in compliance with the Florida Energy specifications covered by this 0° _ Code. calculation_indicates compliance with the Florida Energy Code. PREPARED BY: Before construction is completed w ' DATE: n-11-17 this building will be inspected for Ls;. compliance with Section 553.908 I hereby certify that this building, as designed,is in compliance Florida Statutes. with the Florida Energy Code. OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: 2-1 - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. - Compliance with a proposed duct leakage On requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with Section 803 of RESNET Standards,is not greater than 0.060 On for whole house. 11/11/2017 1:32 PM' EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 FORM R405-2014 PROJECT Title: Neuville 1751 Elev D Bedrooms: 4 Address Type: Lot Information Building Type: User Conditioned Area: 1751 Lot# 29/6 Owner: Total Stories: 1 Block/SubDivision: Silverado Ranch #of Units: 1 Worst Case: No PlatBook: Builder Name: DRH Express Rotate Angle: 90 Street: Permit Office: Cross Ventilation: No _ County:. Pasco Jurisdiction: Whole House Fan: No City,State,Zip: Zephyrhills, Family Type: Single-family FL, New/Existing: New(From Plans) Comment: Garage L Face E CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp v Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Tampa FL_TAMPA_INTERNATI 2 39 91 70 75 645.5 54 Medium BLOCKS Number Name Area Volume 1 Blocki 1751 15181.2 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1751 15181.2 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type- Space Perimeter R-Value Area Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio Main 190.68 ft 0 1751 ftz ---- 0.5 0 0.5 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1897 ft2 0 ftz Dark 0.92 N 0.9 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area FIBS IRCC 1 Full attic Vented 300 1751 ftz Y N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) Main 30 Blown 1751 ftz 0.1 Wood 1 1/1 1/2017 1:32 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 4 FORM R405-20.14 WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 N=>E Exterior Concrete Block-Int Insul Main 4.1 19 .t 4, 8 8 167.6 ft2 0 0 0.6 0 2 E=>S Exterior Concrete Block-Int Insul Main 4.1 43 0 8 8 372.7 ft2 0 0 0.6 0 3 S=>W Exterior Concrete Block-Int Insul Main 4.1 39 8 8 8 343.8 ft2 0 0 0.6 0 4 W=>N Exterior Concrete Block-Int Insul Main 4.1 55 8 8 8 482.4 ft2 0* 0 0.6 0 5 N=>E Garage Frame--Wood Main 11 19 8 8 8 170.4 ft2 0 0.23 0.01 0 6 E=>S Garage Frame-Wood Main 11 12 0 8 8 104.0 ft2 0.23 0.01 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N=>E Insulated Main None .4 3 6 8 20 ft2 2 E=>S Wood Main None .46 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered orientation => changed to As Built rotated 90 degrees). / Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N=>E 1 Vinyl Low-E Double Yes 0.34 0.31 15.5 ft2 1 ft 0 in 3 ft 0 in None None 2 N=>E 1 Vinyl Low-E Double Yes 0.34 0.31 2.5 ft2 8 ft 8 in 0 ft 1 in None None 3 E=>S 2 Vinyl Low-E Double Yes 0.34 0.31 31.0 ft2 1 ft 0 in 0 ft 10 in None None 4 E=>S 2 Vinyl Low-E Double Yes 0.34 0.31 8.0 ft2 1 ft 0 in 0 ft 10 in None None 5 S=>W 3 Vinyl Low-E Double Yes 0.34 0.31 46.5 ft2 1 ft 0 in 0 ft 10 in None None 6 S=>W 3 Metal Low-E Double Yes 0.55 0.34 40.0 ft2 1 ft 0 in 1 ft 6 in None None 7 W=>N 4 Vinyl Low-E Double Yes 0.34 0.31 31.0 ft2 1 ft 0 in 0 ft 10 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 426.09 ft2 426.09 ft2 49.67 ft 8.7 ft 0 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000386 1771.1 97.23 182.86 .2892 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump None HSPF:8.2 28.6 kBtu/hr 1 sys#1 1 1/1 1/2017 1:32 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 4 FORM R405-2014 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit None SEER:14 28.6 kBtu/hr 858 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 50 gal 60.9 gal . 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS / ----Supply---- ----Return---- Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 392 ft2 Main 40 ft2 Proposed Qn Main ---cfm 105.1 cfm 0.06 0.60 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Coolin Jan Feb Mar Apr rX�Ma rX Jun XX��Jul X]Au jXj Se Oct Nov Dec Heating Jan Feb Mar l APr fXl May [ Jun lX]Jul lX]Aug Sep Oct X Nov Dec Ventin [ Jan ( Feb X Mar [ A r [[[X]Ma [[[XXX]]]Jun lXX]]Jul [X]Au Se Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type - 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 7.8 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 11/11/2017 1:32 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 4 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 - The lower the EnergyPerformance Index,the more efficient the home. Zephyrhills, FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1366.40 ft2 b.Frame-Wood,Adjacent R=11.0 274.44 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 10.Ceiling Types Insulation Area 5. Is this a worst case? No a.Under Attic(Vented) R=30.0 1751.00 ft2 6. Conditioned floor area(ft2) 1751 b.N/A R= ft2 7. Windows`* Description Area c.N/A R= ft2 a. U-Factor: Dbl,U=0.34 134.50 ft2 11. Ducts R ft2 SHGC: SHGC=0.31 a.Sup:Attic, Ret:Main,AH:Main 6 392 b. U-Factor: Dbl,U=0.55 40.00 ft2 SHGC: SHGC=0.34 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a.Central Unit 28.6 SEER:14.00 SHGC: d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency SHGC: a. Electric Heat Pump 28.6 HSPF:8.20 Area Weighted Average Overhang Depth: 1.110 ft. Area Weighted Average SHGC: 0.317 8. Floor Types Insulation Area 14.Hot water systems Cap:50 gallons a.Slab-On-Grade Edge Insulation R=0.0 1751.00 ft2 a.Electric EF:0.95 b.N/A R= ft2 c.N/A R= ft2 b. Conservation features None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building 101,0 VCKE$TAl Construction through the above energy saving features which will be installed (or exceeded) 1,0 �o in this home before final inspection. Otherwise, a new EPL Display Card will be completedI fj, r+ based on installed Code rt features. Builder Signature: Date: ��; Address of New Ho me: _ City/FL Zip: - 33 c�DWV "Note: This is not a Building Energy Rating. If your Index is below 70,your home may qualify for energy efficient mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. "'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 11/11/2017 1:32 PM EnergyGauge@ USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 Florida Department of Business and Professional Regulations Residential Whole Building Performance and Prescriptive Methods ADDRESS: Permit Number: Zephyrhills,FL, MANDATORY REQUIREMENTS See individual code sections for full details. 401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law [Section 553.9085, Florida Statues]requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components installed_in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix C. R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.1 through R402.4.4. O R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.The sealing methods between dissimilar materials shall allow for differential expansion and contraction. R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table 402.4.1.1,as applicable to the method of construction. Where required by the code official,an approved third party shall inspect all components and verify compliance. R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2,and 3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g. (50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1. Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2. Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3. Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. O R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers and outdoor combustion air. O R402.4.3 Fenestration air leakage.Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400 or AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. O R402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm (0.944 Us)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential.All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. R403.2.2 Sealing(Mandatory)AII ducts,air handlers,and filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post-construction or rough-in testing below. Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either an energy rater certified in accordance with Section 553.99, Florida Statutes,or as authorized by Florida Statutes,to be"substantially leak free"by either of the following: 1. Post-construction test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square'feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure.All register boots shall be taped or otherwise sealed during the test. 2. Rough-in test:Total leakage shall be less than or equal to 4 cfm (113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25Pa)across the system,including the manufacturer's air handler enclosure.All registers shall be taped or otherwise sealed during the test. If the air handler is not installed at the time of the test,total leakage shall be less than or equal to 3 cfm (85 Umin)per 100 square feet(9.29 m2)of conditioned floor area. Exceptions: 1. The total leakage test is not required for ducts and air handlers located entirely within the building envelope. 2. Duct testing is not mandatory for buildings complying by Section R405 of this code. 11/11/2017 1:32 PM EnergyGauge@ USA-FlaRes2014 -Section R405.4.1 Com Page 1 of 3 FORM R.405-2014 MANDATORY REQUIREMENTS - (Continued) ❑ R403.2.3 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. ❑ R403.3 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C) or below 55°F(13°C)shall be insulated to a minimum of R-3., R403.3.1 Protection of piping insulation. ❑ R403.4.1 Circulating hot water systems(Mandatory). Circulating hot water systems shall be provided with an automatic gr readily accessible manual switch that can turn off the hot-water circulating pump when the system is not in use. ❑ R403.4.3 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 31/2 inches(89 mm)in the hot water distribution line and cold water line located as close as possible to the storage tank. ❑ R403.4.4 Water heater efficiencies(Mandatory). 0 R403.4.4.1 Storage water heater temperature controls . R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature setting range shall be from 100°F to 140°F(38°C to 600C). . R403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s) of combustion types of service water heating systems to be turned off. 0 R403.4.4.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation,Commercial Provisions,for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1. R403.4.4.2.1 Solar water heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors, and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol,Collectors in installed solar water heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and 2. Be installed at an orientation within 45 degrees of true south. ❑ R403.5 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code, Residential or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. ❑ R403.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment. 0 R403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions _ described in Section R302.1.This code does not allow designer safety factors,provisions for future expansion or other factors which affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load,but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.6,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load. 11/11/2017 1:32 PM EnergyGaugeO USA-FlaRes2014 -Section R405.4.1 Com Page 2 of 3 FORM R,405-2014-- (MANDATORY REQUIREMENTS - (Continued) O R403.6.1.1 Cooling equipment capacity.(continued) The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacture's expanded performance data shall be used to select cooling-only equipment.This selection shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower cfm provided by the expanded performance data, the design value for entering wet bulb temperature and the design value for entering dry bulb temperature. Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space. Exceptions: 1. Attached single-and multi-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida-registered engineer,in attached single-and multi-family units,the capacity of equipment may be sized in accordance with good design practice. 0 R403.6.1.2 Heating equipment capacity • R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section R403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load. • R403.6.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.6.1. • R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.6.1. 0 R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. ❑ R403.7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the Commercial Provisions in lieu of Section R403. ❑ R403.8 Snow melt system controls(Mandatory). Snow and ice-melting systems,supplied through energy service to the building,shall include automatic controls capable of shutting off the system when the pavement temperature is above 55°F,and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40oF. ❑ R403.9 Swimming pools,inground spas and portable spas(Mandatory). The energy requirements for residential pools and inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSI/APSP-15.The energy requirements for portable spas shall be in accordance with ANSI/APSP-14. O R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on-off switch that is mounted outside the heater to allow shutting off the heater without adjusting the thermostat setting. R403.9.1.1 Gas and oil-fired pool and spa heaters. All gas-and oil-fired pool and space heaters shall have a minimum thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013 when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights. R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP-of 4.0 when tested in accordance with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required-to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. O R403.9.2 Time switches. Time switches or other control method that can automatically turnoff and on heaters and pumps according to a preset schedule shall be installed on all heaters and pumps.Heaters,pumps and motors that have built in timers shall be deemed in compliance with this equipment. Exceptions: -_ • 1. Where public health standards require 24-hour pump operations. 2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation. O R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Outdoor pools deriving over 70 percent of the energy for heating from site-recovered energy,such as a heat pump or solar energy source computed over an operating season. ❑ RR404.1 Lighting equipment(Mandatory). A minimum of 75 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps. Exception: Low-voltage lighting shall not be required to utilize high-efficacy lamps. 0 R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights R405.2 Performance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R-6. O R405.2.1 Performance ONLY. Ceilings shall have minimum insulation of R-19.Where single assemby of the exposed deck and beam type or concrete deck roofs do not have sufficent space,R-10 is allowed. 11/11/2017 1:32 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Com Page 3 of 3 FORM'R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Neuville 1751 Elev D Builder Name: DRH Express Street: Permit Office: City,State,Zip: Zephyrhills, FL, Permit Number: Owner: Jurisdiction: Design Location: FL,Tampa COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door iambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation,insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations,and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit,or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated,and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall.- Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 11/11/2017 1:32 PM EnergyGauge@ USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Envelope Leakage Test Report. Prescriptive and Performance Method Project Name: Neuville 1751 Elev D Builder Name: DRH Express Street: Permit Office: City,State,Zip: Zephyrhills, FL, Permit Number: Design Location: FL,Tampa Jurisdiction: Cond. Floor Area:: 1751 sq.ft. Cond.Volume: 15181 cu-ft. Envelope Leakage Test Results Leakage Characteristics Regression Data: C. n: R: - CFM(50): Single or Multi Point Test Data HOUSE PRESSURE FLOW: ELA' EgLA: ACH: ACH(50): SLA: R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2,3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3.Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. I hereby certify that the above envelope leakage Where required by the code official, '4.KE STAp performance results demonstrate compliance testing shall be conducted by an �g�' ,, `0 with Florida Energy Code requirements in approved third party. A written accordance with Section R402.4.1.2. report of the results of the test shall be signed by the third party .. �:,... conducting the test and provided to . SIGNATURE: the code official. ' PRINTED NAME: - DATE: BUILDING OFFICIAL: DATE: 11/11/2017 1:33 PM EnergyGaugeO USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 FORM R4Q5-2014 Duct Leakage Test Report Performance Method FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Form R405 Duct Leakage Test Report Performance Method Project Name: Neuville 1751 Elev D Builder Name: DRH Express Street: Permit Office: City,State,Zip: Zephyrhills, FL, Permit Number: Design Location: FL,Tampa Jurisdiction: Duct Test Time: Post Construction Duct Leakage Test Results CFM25 Duct Leakage Test Values Line System Outside Duct Leakage 1 System 1 cfm25(Out) 2 System 2 cfm25(Out) 3 System 3 cfm25(Out) 4 System 4 cfm25(Out) 5 Total House Sum lines 1-4 Duct System . Leakage Divide by (Total Conditioned Floor Area) (On,Out) I certify the tested duct leakage to outside, Qn, is Duct tightness shall be verified by 'V%E S not greater than the proposed duct leakage Qn 0 specified on Form R405-2014. testing to Section 803 of the RESNET Standards by an energy rater certified in 0 accordance with Section 553.99, Florida Statutes. SIGNATURE: IW PRINTED NAME: WE DATE: BUILDING OFFICIAL: DATE: 11/11/2017 1:33 PM EnergyGauge@ USA-FlaRes2014 -Section R405.4.1 Compliant S Page 1 of 1 Manual S Compliance Report Job: -�- wrightsoft� p P Date: Sep 04,2015 Entire House By: Progressive Air Systems, Inc 5907 Dasher Ct,Port Richey,FL 34668 Phone:'727-847-3898 Fax:727-815-3399 License:CAC033669. Project • • For: DR Horton/Express Lot 29 Blk 6 Silverado Ranch, Zephyrhills, FL C66ling Equipment Design Conditions Outdoor design DB: 91.2°F Sensible gain: 21774 Btuh Entering coil DB: 76.1 OF Outdoor design WB: 77.1 OF Latent gain: 2957 Btuh Entering coil WB: 63.0°F Indoor design DB: 75.0°F Total gain: 24731 Btuh Indoor RH: 50% Estimated airflow: 1000 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB030****A+FB4CNP030 Actual airflow: 1000 cfm Sensible capacity: 23399 Btuh 107%of load Latent capacity: 3923 Btuh 133%of load Total capacity: 27322 Btuh 110%of load SHR: 86% Heating Equipment Design Conditions Outdoor design DB: 40.0°F Heat loss: 20877 Btuh Entering coil DB: 69.6°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB030****A+FB4CNP030 Actual airflow: 1000 cfm Output capacity: 25626 Btuh 123%of load Capacity balance: 31 OF Supplemental heat required: 0 Btuh Economic balance: -99 OF Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 1000 cfm Output capacity: 5.8r kW 95%of load Temp. rise: 50 OF. Meets are all requirements of ACCA Manual S. .0 wri htsoft° 2017-Nov-1113:35:14 ^, 9 Right-Suite®Universal 2017 17.0.21 RSU25554 Page 1 �� ...ightsoft Files\Express homes\Neuville-1751.rup Calc=MJ8 House faces: E Form Load Short Fo Job: wrightsoft® Date: Sep 04,zoi5 Entire House By: Progressive Air Systems, Inc 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 Project • • For: DR Horton/Express Lot 29 Bik 6 Silverado Ranch, Zephyrhills, FL Design Information Htg Clg Infiltration Outside db(OF) 40 91 Method Simplified Inside db(OF) 70 75 Construction quality Semi-tight Design TD (OF) 30 16 Fireplaces 0 Daily range - L Inside humidity (%) 50 50 Moisture difference(gr/lb) 26 54 HEATING EQUIPMENT COOLING EQUIPMENT Make Carrier Make Carrier Trade CARRIER Trade CARRIER Model CH14NB030****A Cond CH14NB030****A AHRI ref Coil FB4CNP030 AHRI ref Efficiency 8.2 HSPF Efficiency 11.5 EER, 14 SEER Heating input Sensible cooling 22500 Btuh Heating output 29600 Btuh @ 47°F Latent cooling 7500 Btuh Temperature rise 27 OF Total cooling 30000 Btuh Actual air flow 1000 cfm Actual air flow 1000 cfm Air flow factor 0.048 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.88 Capacity balance point=31 OF Backup: Input=6 kW, Output= 19779 Btuh, 100 AFUE ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) great room 403 5512 7693 264 353 M bed 209 3334 2888 160 133 M bath 76 1035 529 50 24 M wic 55 64 95 3 4 laundry 64 75 731 4 34 bed3/study 182 1924 1463 92 67 kitchen 219 1391 2267 67_ 104 bed2 154- 1379 1091 66 50 bath2 63 666 317 32 15 bed3 167 3666 2413 176 111 foyer 150 1832 2287 88 105 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wri htsoft¢ 2017-Nov-1113:35:14 9 Right-Suite®Universal 2017 17.0.21 RSU25554 Page 1 ...ightsoit Files\Express homes\Neuville-1751.rup Calc=MJ8 House faces: E Entire House d 1740 20877 21774 1000 1000 Other equip loads 0 0 Equip. @ 1.00 RSM 21774 Latent cooling 2957 TOTALS 1740 20877 24731 1000 1000 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wri htsaft` 2017-Nov-1113:35:14 ^� '�' 9 Right-Suite®Universal 2017 17.0.21 RSU25554 Page 2 ACCX ...ightsoft Files\Express homes\Neuville-1751.rup Calc=MJ8 House faces: E Project Sum 117a1'y Date: Sep 04,2M - vvrightsoft® Entire House By-- Progressive Air Systems, Inc 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 •]ect information For: DR Horton/ Express Lot 29 Blk 6 Silverado Ranch, Zephyrhills; FL Notes: Design Information Weather: Tampa Intl AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 40 OF Outside db 91 OF Inside db 70 OF Inside db 75 OF Design TD 30 OF Design TD 16 OF Daily range L Relative humidity 50 % Moisture difference 54 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 17189 Btuh Structure 16565 Btuh Ducts 3687 Btuh Ducts 5209 Btuh Central vent(0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 20877 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 21774 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 2301 Btuh Ducts 656 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling (none) Area(ft2) 1740 1740 Equipment latent load 2957 Btuh Volume(ft3) 15314 15314 Air changes/hour 0.26 0.14 Equipment total load 24731 Btuh Equiv.AVF(cfm) 66 36 Req.total capacity at 0.75 SHR 2.4 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER Trade CARRIER Model CH14NB030****A Cond CH14NB030****A AHRI ref Coil FB4CNP030 AHRI ref Efficiency 8.2 HSPF Efficiency 11.5 EER, 14 SEER Heating input Sensible cooling 22500 Btuh Heating output 29600 Btuh @ 47OF Latent cooling 7500 Btuh Temperature rise 27 OF Total cooling 30000 Btuh Actual air flow 1000 cfm Actual air flow 1000 cfm Air flow factor 0.048 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.88 Capacity balance point=31 OF Backup: Input=6 kW, Output= 19779 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wri htSOFt" 2017-Nov-1113:35:14 �� 9 Right-Suite®Universal 2017 17.0.21 RSU25554 Page 1 ..ightsoft Files\Express homes\Neuville-1751.rup Calc=MJ8 House faces: E FORM R405-2014 RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST Florida Department of Business and Professional Regulation Simulated Performance Alternative(Performance)Method Applications for compliance with the 2014 Florida Building Code, Energy Conservation via the residential Simulated Performance method shall include ❑ This checklist ❑ A Form R405 report that documents that the Proposed Design complies with Section R405.3 of the Florida Energy Code. This form shall include a summary page indicating home address, a-ratio and the pass or fail status along with summary areas and types of components, whether the home was simulated as a worst-case orientation, name and version of the compliance software tool, name of individual completing the compliance report(1 page)and an input summary checklist that can be used for field verification (usually 4 pages/may be greater). ❑ Energy Performance Level(EPL) Display Card(one page) ❑ Mandatory Requirements(three pages) Required prior to CO for the Performance Method: ❑ Air Barrier and Insulation Inspection Component Criteria checklist(Table R402.4.1.1 - one page) ❑ A completed Envelope Leakage Test Report(usually one page) ❑ If Form R405 duct leakage type indicates anything other than "default leakage", then a completed Form R405 Duct Leakage Test Report(usually one page) EnergyGauge@-USRCZB v5.1 1 1/1 1/2017 12:42:50 PM Page 1 of 1 ENVIRONMENTS FOR SITE ID:391934 LOT:29 BLOCK 6 HOUSE:856JS :Fe'�TON IT T ` T CITY:ZEPHYRHILLS STATE:FL ZIP:33541 COUNTY:PASCO ACCOUNT#:gD9DRHFL BUILDER:D R HORTONVERADO COMMUNITY:39163 PLAN:NDP12/122018 PROGRAM:HERS1700% TESTER:EFL IECC:2009 CLIMATE ZONE: PROPERTYOWNER: PROPERTYADD WATRAILST Z13HYRHILLS,FL33541 TE T:BLOWS DOOR SULT: PASS TESTER: Michael Silberatein DATE:07252018 TESTNAME CORRECTION BUILDER RATER WA NEEDED VERIFIED VERIFIED 5.1 Attic Access Panel(fully gaskeled and insulated) X 5.2 Attic drop-down Stair fully gaskeled and insulated) X 5.4 Recessed Lighting Fixtures(ICAT labeled and sealed to drywall) X 5.5 Whole-house Fan(insulated gasketed to the opening X 7.3 Fresh air ventilation installed per programspecs x Blower Door BUILDING ORIENTATION PROGRAM CODE PROGRAM CODE VOLUME(CU. VOLUME CU. SHELL(SQ.FT) SHELL(SO.FO 'WA 15',190 0 0 PROGRAM CODE PROGRAM CODE PROGRAM CODE CFM 50 CFM 50 ACH 50 ACH 50 %of Shell %of Shell BD Target 0 11,772 7 BD Acbral 1,274 5.03 Meter# Room Pressure Test Mat Bdnn 0 Bdmt 2 1 D 1 Bdrm 3 0 Bdrm 4 0 Bdrm 5 0 1 Rm 1 D Rm 2 0 Rm 3 0 Other 0 CO Detectors Energy Star Qualified Appliances? Efficient Lighting Package? 60 or a Of Hardwired Lights Must Be CFL Or LED Low Flow Faucets,Toilets etc? Programmable Thermostat? Certified Green Program Level Requires Visual Inspection Mechanical System Item Location Manufacturer Name Model#1 Model#2 Model#3 Model#4 SYSTEM 1 WATER HEATER SYSTEM 2 WATER HEATER SYSTEM 3 WATER HEATER SYSTEM 4 WATER HEATER SYSTEM FURNACE SYSTEM 1 HVAC OUTDOOR UNIT OUTSIDE SYSTEM 1 HVAC INDOOR COIL SYSTEM 1 HVACAHU(HEAT INTERIOR PUMP) SYSTEM 2 FURNACE SYSTEM 2 HVAC OUTDOOR UNIT SYSTEM 2 HVAC INDOOR COIL SYSTEM 2 HVAC AHU(HEAT PUMP) SYSTEM FURNACE SYSTEM HVAC OUTDOOR UNIT SYSTEM 3 HVAC INDOOR COIL SYSTEM HVAC AHU(HEAT PUMP) SYSTEM 4 FURNACE SYSTEM 4 HVAC OUTDOOR UNIT SYSTEM 4 HVAC INDOOR COIL SYSTEM HVACAHU(HEAT PUMP) BUILDING SPECIFICATIONS BUILDING CHARACTERISTICS ASDESIGN-VALUES ASBUILT-VALUES COMMMENT #OF BEDROOMS(REM) NA NA CEILING FLAT(REM) NA NA SEALED ATTIC(REM) NA NA VAULTED CEILING(REM) NA NA FOUNDATION WALLS(REM) NA NA EXPOSED FLOOR(REM) NA NA ABOVE GRADE WALLS(REM) NA NA DUCT SUPPLY R-VALUE(REM) NA NA DUCT RETURN R-VALUE(REM) NA NA PROGRAMMABLE THERMOSTATS(PRIF) WATER HEATER TYPE(PRIF) WATER HEATER FUEL TYPE(PRIF) TEST:BLOWER DOOR RESULT:PASS TESTER:Michael Silberstein DATE:072SJ2018 BUILDING SPECIFICATIONS • BUILDING CHARACTERISTICS ASDESIGN-VALUES AS BUILT-VALUES COMMMENT WATER HEATER SIZE, EFFICIENCY& LOCATION (PRIF) INFILTRATION(HOUSE LKG)ACH(REM) NA Htg:5.03 Clg:5.03 ACH @ 50 Pascals FRESH AIR VENTILATION TYPE(PRIF) VENTILATION FAN MANUFACTURER(REM) NA NA VENTILATION FAN MODEL#(REM) NA NA VENTILATION FLOW REQUIRED(REM) NA NA VENTILATION EQUIP.RATED CFM(REM) NA NA VENTILATION#OF FANS(REM) NA NA VENTILATION TIMER SETTING EACH FAN(REM) NA NA VENTILATION TIME-HRS/DAY SPECIFIED(REM) NA NA VENTILATION TIME SET BY HVAC CONTRACTOR- MINUTES PER HOUR(PRIF) FRESH AIR VENTILATION FAN WATTS(REM) NA NA MEASURED FAN WATTS OR PER MANUFACTURER'S SPEC'S(PRIF) INTERIOR%OF CFUS(PRIF) INTERIOR%OF PIN-BASED(PRIF) EXTERIOR FIXTURES(%)(PRIF) GARAGE FIXTURES(%)(PRIF) DISHWASHER(PRIF) REFRIGERATOR(PRIF) FOUNDATION TYPE(PRIF) SLAB TYPE(PRIF) SLAB AREA(PRIF) SLAB DEPTH(PRIF) SLAB FULL PERIMETER(PRIF) SLAB GRADE(PRIF) FLOW RING(PRIF) HEATING(REM) NA NA COOLING(REM) NA NA AIR-SOURCE HP(REM) NA NA WATER HEATING(REM) NA NA TEST:DUCT BLASTER RESULT:PASS TESTER:Michael Silberstein DATE:07252018 TOTAL CONDITIONED FLOOR AREA 0 1.752 (CPA SO FT) DUCT LEAKAGE TO OUTSIDE%TARGET 0.00% 3.00% TOTAL DUCT LEAKAGE%TARGET 0.00% 8.00% SYSTEM 1 SO FT.SERVED(CFA) 0 1.752 POST CONSTRUCTION SYSTEM 1 DUCT LEAKAGE TO OUTSIDE 0 53 SYSTEM 1 DUCT LEAKAGE TO OUTSIDE 12 SYSTEM 1 DUCT LEAKAGE TO OUTSIDE Infinity% 0.68% (CFM25)TARGET (CFM25)ACTUAL (%OF CFA)ACTUAL SYSTEM 1 TOTAL DUCT LEAKAGE 0 140 SYSTEM 1 TOTAL DUCT LEAKAGE SYSTEM 1 TOTAL DUCT LEAKAGE(%OF NaN% 0.00% (CFM25)TARGET (CFM25)ACTUAL CFA)ACTUAL SYSTEM 2 SQ FT.SERVED(CFA) 0 0 SYSTEM 2 DUCT LEAKAGE TO OUTSIDE SYSTEM 2 DUCT LEAKAGE TO OUTSIDE SYSTEM 2 DUCT LEAKAGE TO OUTSIDE (CFM25)TARGET 0 0 (CFM25)ACTUAL (%OF CFA)ACTUAL SYSTEM 2 TOTAL DUCT LEAKAGE 0 0 SYSTEM 2 TOTAL DUCT LEAKAGE SYSTEM 2 TOTAL DUCT LEAKAGE(%OF (CFM25)TARGET (CFM25)ACTUAL CFA)ACTUAL SYSTEM 3 SO FT.SERVED(CFA) 0 0 SYSTEM 3 DUCT LEAKAGE TO OUTSIDE 0 0 SYSTEM 3 DUCT LEAKAGE TO OUTSIDE SYSTEM 3 DUCT LEAKAGE TO OUTSIDE (CFM25)TARGET (CFM25)ACTUAL (%OF CFA)ACTUAL SYSTEM 3 TOTAL DUCT LEAKAGE SYSTEM 3 TOTAL DUCT LEAKAGE SYSTEM 3 TOTAL DUCT LEAKAGE(%OF (CFM25)TARGET 0 0 (CFM25)ACTUAL CFA)ACTUAL SYSTEM 4 SO FT.SERVED(CFA) 0 0 SYSTEM 4 DUCT LEAKAGE TO OUTSIDE 0 0 SYSTEM 4 DUCT LEAKAGE TO OUTSIDE SYSTEM 4 DUCT LEAKAGE TO OUTSIDE TEST:DUCT BLASTER RESULT:PASS TESTER: Michael Sllberetein DATE:07252018 (CFM25)TARGET (CFM25)ACTUAL (90 OF CFA)ACTUAL SYSTEM 4 TOTAL DUCT LEAKAGE SYSTEM 4 TOTAL DUCT LEAKAGE SYSTEM 4 TOTAL DUCT LEAKAGE OF (CFM25)TARGET 0 0 (CFM25)ACTUAL CPA)ACTUAL BUILDING SPECIFICATIONS BUILDING CHARACTERISTICS ASDESIGN-VALUES AS BUILT-VALUES COMMMENT DUCT LEAKAGE TO OUTSIDE(REM) NA 0.007 CFM25/CFA TOTAL DUCT LEAKAGE(REM) NA - 0.08 CFM25/CFA ' FLOW RING(PRIF) FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION f Envelope Leakage Test Report /l� Prescriptive and Performance Method Project Name: SILVERADO Builder Name: D R HORTON Street: 6581 Wagon Trail St Permit Office: City,State,Zip: Zephyrhills,FL 33541 Permit Number: Design Location: 6581 Wagon Trail St(Lot 29) Jurisdiction: Cond.Floor Area: 1752 Cond.Volume: 15190 Envelope Leakage Test Results Leakage Characteristics Regression Data: C: n: R: CFM(50): 1274. Single or Multi Point Test Data ELA: 70 HOUSE PRESSURE FLOW: EgLA: 166 1 50 Pa 1274 cfm ACH: 5.03 2 0 Pa 0 cfm SLA: .04 3 0 Pa 0 cfm 4 0 Pa 0 cfm ACH(50)*: 5.03 *For prescriptive projects,tested leakage must be<=7 5 0 Pa 0 cfm ACH(50). For performance projects, tested leakage must be<=the ACH(50)shown on Form R405-2014 6 Pa cfm for this project. R402.4.1.2 Testing.The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zones 1 and 2.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statutes or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration 3.Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test;shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. I hereby certify that the above envelope leakage performance results demonstrate compliance with Florida Energy Code requirements in accordance with Section R402.4.1.2. Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statutes 0, or or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party.A FIq written report of the results of the test shall be signed Di9itally signed by Michael by the third party conducting the test and provided to Silberstein the code official. , Date:2018.07.2511:44:50 EDT Z CN=Michael Silberstein,O=TopBuild Home Services,OU, Op EMA I LADDRES S=Mich ael.Si Iberstei Signature: n@topbuild.com,C=US Printed Name: Michael Silberstein BUILDING OFF IAL: '`c- Date: 07/25/2018 DATE: Thank you for allowing TopBuild the opportunity to provide the above services for you.Please feel free to contact me with any questions. 10/25/2017 391934 FLORIDA ENERGY EFFICIENCY CODE • FOR BUILDING CONSTRUCTION Form R405 Duct Leakage Test Report Performance Method Project Name: Silverado Builder Name: D R Horton Street: 6581 Wagon Trail St Permit Office: City,State,Zip: Zephyrhills,FL 33541 Permit Number: Design Location: Jurisdiction: Duct Test Time: Post Construction Duct Leakage Test Results CFM25 Duct Leakage Test Values Line System Outside Duct Leakage 1 System 1 12 cfm25(Out) 2 System 2 cfm25(Out) 3 System 3 cfm25(Out) 4 System 4 cfm25(Out) 5 Total House Duct Sum lines 1-4 12 System Leakage Divide by 1752 (Total Conditioned Floor Area) 0.0068 (Qn,Out) I hereby certify that the above duct testing performance Duct tightness shall.be verified by testing to results demonstrate compliance with the Florida Energy Section 803 of the RESNET Standards by an 4'C�Sr't?. Code requirements in accordance with Section R403.2.2. energy rater certified in accordance with tiO Section 553.99,Florida Statutes. IN Digitally signed by David DeForest Date:2018.07.2511:44:46 EDT Rater Of Record: aa...,c aa.oz-6 CN=David DeForest, , �10, e Tep�Beild llewe Ss,vieas, fA• b .�c' 6 ` Printed Name: David DeIdFIDDtxess-david deroreo Y RESNET#: 6963316 t@tepbajta.com,c=us G'OO�.tg Building Official: kf k' Digitally signed by Michael Date: Silberstein Dale:2016.07.25 11:44:47 EDT Completed By: CN=Michast Silberstein, 'PULL ra-aotrressrares>^ Printed Name: Michae kf;d ��_„-�, RESNET#: ERKML6 rsteln@topbuild.com,C=US Date: 07/25/2018 Thank you for allowing TopBuild the opportunity to provide the above services for you.Please feel free to contact me with any questions. 391934 .RESNET Home Energy Rating Standard Disclosure For home located at: Lot 29 6581 Wagon Trail St,Zephyrhills,FL 33541 City: Zephyrhills State: FL 1. X�The Rater or Raters employer is receiving a fee for providing the rating on this home. 2. X�In addition to the rating,the Rater or Raters employer has also provided the following consulting services for this home. A. Mechanical system design B. Moisture control or indoor air quality consulting C. Performance testing and/or commissioning other than required for the rating itself X D. Training for sales or construction personnel E. Other(specify below) 3. The Rater or Raters employer is: A. The seller of this home or their agent B. The mortgagor for some portion of the financial payments on this home C. An employee,contractor or consultant of the electric and/or natural gas utility serving this home 4. The Rater or Raters employer is a supplier or installer of products,which may include: Installed in this home by: OR is in the business of: HVAC Systems Rater Employer Rater Employer Thermal Insulation Systems Rater Employer Rater Employer Air sealing of envelope or duct systems Rater Employer Rater Employer Windows or window shading systems Rater Employer Rater Employer Energy efficient appliances Rater Employer Rater Employer Construction(builder,developer,construction contractor,etc.) Rater Employer Rater Employer Other(specify below): Rater H Employer Rater Employer I attest that the above information is true and correct to the best of my knowledge.As a Rater or Rating Provider I abide by the rating quality control provisions of the Mortgage Industry National Home Energy Rating Standard as set forth by the Residential Energy Services Network (RESNET).The national rating quality control provisions of the rating standard are contained in Chapter One 4.C.8.of the standard and are posted at http://resnet.us/standards/RESNET Mortgage_Industry_National_HERS_Standards.pdf.The Home Energy Rating Standard Disclosure for this homeis available from the rating provider. Michael Silberstein RESNET#:ERKML6 Raters Printed Name Certification# July 25,2018 Raters Signature Date RESNET Form 0300-2 REM/Rate-Residential Energy Analysis and Rating Software v14.5.1 This information does not constitute any warranty of energy cost or savings. ©1985-2014 Architectural Energy Corporation,Boulder,Colorado. 391934 5335,31 g0gg2gGG�Q Q►� of C� E G s O RNORE�� 0 Sfk. ` o vJrec. 1260 Q���E ONs��gFR . 140tK�ype; NI 0 �NP�'o LS,F ddKess• ZEpNERp'OO80'00600�0290 A sUbd,V. 05 26 2�.00 O� PQP�`Gp,B1. Ppp�'�cNo's Co"stcu�t1O��ype. NO Use C%assif� 'atio 19A65 er: "BUILD, permit Nu�'a 8�01120�$ .. gploP LoiM i0 DA YS OF I ate ssuE ANCE vE PRIOR To liG N 8R M R � DS1T