18-19501
CITY OF ZEPHYRFtILLS 5335-8TH STREET-. (813)780-0020'T 19501 BUILDING PERMIT SINGLE...FAMILY RESIDENTIAL PERMIT INFORMATION LOCATION INFORMATION Permit#:19501 Issued: 4/02/2018 Address: 6671 PADEN WHEEL ST Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Lot( ): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 618,561.15 Total Fees: 12,800.19 Subdivision: SILVERADO Amount Paid: 12,800.19 Date Paid: 4/02/2018 Parcel Number: 05-26-21-0070-00400-0180 CONTRACTOR INFORMATION OWNER INFORMATION Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC Addr: 4600 W. CYPRESS ST STE 200 Address: 4600 W CYPRESS ST STE 200 TAMPA, FL. 33607 TAMPA FL 33607-4099 Phone: (813)574-5743 Lic: Phone: Work Desc: CONSTRUCT SINGLE FAMILY 5,491 SQ FT APPLICATION FEES BUILDING FEE 2,044.52 ELECTRICAL FEE 433.35 PLUMBING FEE 288.90 MECHANICAL FEE 202.23 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE-sfr/100% 4,828.00 SCHOOL IMPACT FEE-sfr/1% 48.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32 N" W-Cu '° =� I :Ins ections Recjuir6C FOOTER 2ND ROUGH PLUMB Misc INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public record_s of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing, consult with your lender or an attorney before recording your notice of commencement." Complete Plans;Specifications and Must Accompany Application. All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. rd AJ,�� &-- f"�* TRACTORS SIGNATURE PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER u�oC Je StrearnO Ultra Blowing Wool Insulation HA NMOBt Atic and Cavity Wall Card -yaw &L, ULk)s�, i Balls and Blankets Eq6ipment Required When Installed in accordance with the monufacturel's It Is recommended that a pneumatic blowing machine and.a congated.hose vAth aminimum Y4'Internal corruption.a minimum length recommendations','Knaiul'Insulation bafts.and.We nkets will of 150'..Colis In the hose should not be less than366 in di -35 lbsimi nute.Recommended feed diameter.Acceptable material feed rate js,� p vide the full R-Valtie� f-i provide e rate is 15-25 lbs,m nrute. R-Value* Minimum Thickness Thermal Performance(SideWalfandrAftic Application Y To obtain an The stated thermal resistance(R-value)Is provided by,Installing In accordance with the manufacturer's instructions.Failure to Install the Insulation resistance Installed Insulation should re.quire-d number of ba�s 0 1 r 1,000 s a et of covers 6 per b ag as recommended by the label ,quare feet and exceeding the maximum sqY re f6 {R-value)of: not bie,16ss than: will result In lower Installed R-values.Field blending of this product with other loose en n recommended b 111041ufa�turer.ose fill insulations is not reco eff y R49 13.75" Cavity Wall Bag get Weight-Norn inal-32 1-b-i.,Minimum.- o-"l 1-b-s. R-38HD-- 10.25" R-38 R-Value* 'Bags pe(1000 SF maximum Net Minimum Dr To obtain an Coverage,per Bag. Weight per SF 'R-30H The�number of,bags 'Insulation per 1, Tict6a-re feet Contentsof this The weight per square- R40, 10.00" Cavity reslitanc6 of not area should not bag should not fail of installed In6lation -R-26 9.00" Framing Depth of: Density -be Idss than: cover more.Abort: should nor be less than: R-22 21,X 4" 21.50" R-,15 1.8 lbs./cu.ft. 16'.4 bags 61.0 sq.ft. 6.525 ilos, U1 HD' 5-6V 2"X 6` 5..,-50 R-23 1:8 lbs.ku.It. 25.8 bags 38;8 sq;it 0.82.5 lbs, R-1 9 6.25' 7X V 7.2Y A. 1. lbsjcu.6. 34.6 bags' 29A q.ft. 1.088 Ibs. R-15HD 3.50i �1 8 I _I - R-1 3 3.50"- 2"x 10- 925" k-39 1 1.8 lbs;/Cu.ft.. 43.4 bags 23.1sq.ft. 1'.388 lbs. R-1 1 3.50" R means resistance to'heal flow.the higher the R-malue,the greater 1-h-0 insulating power.To get the marked R-value,it essential that ft Insulation tie installed propedy, R-8- -2.50" "11-11lin 0.5"Cavity.-Conforms IoASTM G M and Feadal Open Attic Application Bag Ndt.Wellght-Noinlnal 32 lbs.,Minimum.31 lbs. Specificalhoni'll-11+52117. Minimum Bags/ Mixinuirn Minimum Initial Settled Framing Adjustment., I,0-00--SF' Coverage Weight; Installed -Thickness** To,compensite for framingmembers,the number of kags per The number of bag 1,000 Sf of net a s/ Contants.of,this The weight/SF Thickness Contents of this 1,00.9 Pq.ft.of area to be Insulated should.be as shown below. R-Mue* rea bag should not of Installed Installed Insulation bag should To'obtaln an Insulation should not be less cover Insulation should not should not be less not cover more -Bags/MSF Bags/MSF reslstan*ca�(R-Valuie)of,. thin: more t1han:• be[a"than than: thain-i Joist 16"0.C. 24!'D.C. 114alue Dimensions Framin Framing I R460 29.7 33.6 SF 952 lbs 19.750 19.750" 9 2x4' 29.2 29.4 R49 23.5 42.5 SF ..753 tbs. 16.376" 16;375" R-60, 26 28;,9 - 29A R-44 .20.9 47.9 SF .670 lbs. 14.875" 14.875' 2x8 28,6 28.9 R48 17.8 56.2 SF 569 lbs. 13.000" 13.000" 2x4 23.0- 23;2 R-.30. 13.6 .73.3$F AR tbs. 10.375'f 10.375" R-49 2x6 -22.7 22.'9 R-26, 11.8 85.6 3F .377 lbs7--F 5.1 N 9.-125"- 2x8 '22.4 .22.7 2x4 -20.4 20.6., R-22 9..8 102.2 SF 717.760, 7160' R-44 2k6 20.1 20.3 R-1 9 8A 119.3 SF .269 lbs. 6175V 6.750" -19.8 -20�.1, R-13 5.7 175.3 SF I i,�- 4 4.750'; '4 --- t 2x4. 17.3- 17.4'--- -RA 1. 4,7 210.8 SF J52 16s. .4.000" 4-000" R-38 2x6 17-.0 17:2 -2x8 16.7 17.0 2X4 -13.2 13.3. 11140 2x6 12,94 -2X8 '12'8 12.9 2x4 111.,3 11.4 yo hww i 15orefth Kd t*rrvk of Urh W 111.0 11,2 % R-;26 2X6 Builder's Insulation Statement 2Y8 10.8 .11.0 Jet Stream Ultra has been Installed in-conformande With the included reodrnmendafions to proVid&.01herml resistance of.. - 20 9.3 9.5, R-Value Thickness R-22 2x6 9;1 9�3 - . Attic Area R- at Inches. 2x8 8.8 Sloped Callings- R- at Inches 2x4 7:9 .8.1 Walls R- at inches 11-1 2x6 7.7 7.9 2x8 7A • 7.7 Floors(over an unheatedcrawlspace) R-1 at Inches. 2x4 5.3 5A Crawl Space Pedm6ter R- at Inches R-1 3 2x6 5.0 5.2 Date Installed 2x8 4.8 &0 Blown insulation has been Insta�d In conformance with the above,recommendations to provide an RTvalue of: 20 4.3 4A R-- 0 uilho 2-5, bags of this Insulation to Cover 2-If I square feet of area R;1 1 2x6 4.1 4.3 at�51nlrnumr thickness of 0 7 Inches, I 2x8 1 3:8 4.1 UL EnW-n? ANN% GREENG40u)G.ld- LIJ It-rill '0 lm,.49-6,,dd[�g%0.11., ,N Company Cafe ULV,1--1GRHNGUARDG.W. UL C01-im�Ww ro;a 6T.Y.hyd. - UL End-ant GRUNGUARD Home Wider(signature) Carflfl=flon ga,6m. Kdw--1xd m LIL GREENGUM11 �s f P.�dr Company Date The coverage information on this Attic/Sidawall'card applies to the- entire-United States(Including Min-hesilta). Knauf Insulation,Inc, .One Knauf Drive,Shelbyville,IN 46176 Tel:(800)825-4434 ext.8300 FAX:(317)398-3675 nc?nl s Knafif Ihqi jlntihfi Inh U11011in:;anil Con"ItictiUn Services MCS) PA.S C COUNTY Fl_C)im)A' . Blower Door Test Report Form . Property Address: I /7 I I l(J S7� PermitC: O I TenitComvanyName:S"EM restoate: Tesler rume,HASSEN KHELTI Testereenn.MY3YG6 c.,t ,Pt..:904-903-1076 E.�:liklielifi@sk etec.com. 402A.1.2 Testing.Building erivelopc air tightness shall be demonstrated by Section 402A.1.2 1 - - I The building or dwelling runt shall be tested,and v«ifie d as haying an air leakage rate of not exceeding 5 air changes j per .hour. Testing shall be cunductcxl with wblower door at a pressure of0.2 inches w.g.(50 Pascals).As required by the Building Official;testing stall be cexiduetieel by an approved third parry.A written report of the results of the tot' shall tic signed by the party conducting.the test(including Agency Name)and provided to the Building Official prior to Certificate of Occupancy issuance.Testing shall be performed at anytime after creation oral[scheduled penetrations of the building thermal envelope- During testing:`(check to verify aondrtion met) ; Exterior windows and doars,fireplace and stove doors shall be closed,but not sealed,beyond the intended weather-stripping or other Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be dosed,but not sealed beyond �/ it infiltration j interior doors,if installed at the.time of the test,shall be open p/Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed { v, }a treating and cooling systems,if installed at the time of the test;shall be turned off - Vt 'l Supply and return registers,if,installed at the time of the test,-shall be fully;open- Vh Buildingvolurne(ti;) = l Qso Airflow at 50 Pascal(CFM) _ j ACHso Air changes per hour at 50 Pascal Qso x 60_Vb 7 ACHso(3.0 ACH minimum) j Passk Fail ❑ ❑Outside Air mechanically introduced to space(less than 3.0 ACH) l hereby certify that the above envelope leakage performance results demonstrate compliance ttrith Florida Energy Code requirements in accordance with Section R402.4.1.2. i Signature of Tester Dat I i I PA,SCO COUNTY, FLORIDA ' ` Permit o S -?S. 'Date Permitted Builder Name/Owner Name L.-tr „le t-�. Control#`" County Parcei Nis, C► Z�-2 t-.Cj} Z�/a--two-D!c subDiv: Sir va Address/Location tQ Z `I'Gc.UYe IALL'f'�•1 t>'�� Ctassificatlonti'` of Us � � f yp••_•_ ! c� ��. GL.f TRANSPORTATION IMPACT FEE Rate: �— Sg,Ft Exempt ❑Yes ❑ No How Determined Impact Fee Amount $tr ,j 2 Zone No. TAZ:: SCHOOL IMPACT FEE7r - Account (050). Single-Family Detached House Amount (057) Mobile Home {058) Other Residential 23) Collection Fee Exempt b Yes n•No Hoye,Determined PARKS AND RECREATION.FEE Land Account Land Credit Land Total Recreation Account Recreation Credit -Recreation Total Zone TOTAL AMOUNT $ Exempt ❑Yes No How Determined LIBRARY FEE. Land Account Land Credit Land Total Facility Account Facility Credit Facility Total Exempt ❑Yes ❑No How Determined Total Amounfaf RESOURCE FEE ERU TOTAL AMOUNT Prepared By Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE.OF PASCO COUNTY AcknowledgementbeloW does not Imply acceptance of concurrence,but simply raosipt of•a copy of this form,placing the building permit owner on notice of this assessment and the conditions of payment for same. i DATE RECENED BY RECEIPT NO. DATE BY I i Builder Name/Owner Name 15 h _t-L L(� Control#' County Parcel No. Q5-24 2j_�Z b--06 O-D_l_c.�tD SubDiv: c Address/Location Z� F G den IA At,Lw Classificationtrype of Use cl t ly TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: Exempt []Yes [] No How Determined Impact Fee Amount $,fir(�3 2 Zone No. TAZ: :f. SCHOOL IMPACT FEE Account (0561 Single-Family Detached House Amount $ (057) Mobile Home (058) Other Residential 123) Collection Fee Exempt [ Yes ❑ No How Determined PARKS AND RECREATION FEE Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation Total Zone TOTAL AMOUNT $ Exempt ❑Yes ❑ No How Determined LIBRARY FEE Land Account Land Credit Land Total Facility Account Facility Credit Facility Total Exempt ❑Yes ❑ No How Determined Total Amoun RESOURCE FEE ERU TOTAL AMOUNT ` Prepared By Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY Acknowledgement below does not imply acceptance of concurrence,but simply receipt of a copy of this form,placing . the building permit owner on notice of this assessment and th$conditions of payment for same. DATE RECEIVED BY RECEIPT NO. DATE BY 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received Phone Contact for Permitting 813 363 _ 2891 1 .1 1 1 1 1 1 1 1 1 1 1 1 Owner's Name Lennar Homes,LLC Owner Phone Number r8l3L574,5700 Owner's Address 1 4600 W.Cypress St.Ste.200,Tampa,FL 33607 Owner Phone Number Fee Simple Titleholder Name I N/A Owner Phone Number Fee Simple Titleholder Address N/A JOB ADDRESS 6671 Paden Wheel Street LOT# 0180 SUBDIVISION Silverado Ranch Subdivision Ph 2,3,&4 PARCEL ID# 05-26-21-0070-00400-0180 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR e ADD/ALT = SIGN = = DEMOLISH li_�11 INSTALL REPAIR PROPOSED USE SFR 0 COMM = OTHER TYPE OF CONSTRUCTION [F,/ BLOCK Q FRAME = STEEL = DESCRIPTION OF WORK Single Family Residence/Pool/Screen Enclosure/Fence BUILDING SIZE U/R IF 5491 SQ FOOTAGE 4259 HEIGHT 2 Story ��BUILDING $ l/ VALUATION OF TOTAL CONSTRUCTION I�ELECTRICAL $ 7 Q J ® PROGRESS ENERGY Q W.R.E.C. AMP SERVICE PLUMBING $ MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION L =GAS F4 ROOFING SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS I FLOOD ZONE AREA DYES DO —' I_I . BUILDER COMPANY Lennar Homes,LLC SIGNATURE F REGISTERED Y/ N FEE CURREN Y/N Address 4600 W.Cypress Z1 Ste.200,Tampa,FL 33607 License# I CGC1518166 ELECTRICIAN COMPANY Edmonson Electric, Inc. SIGNATURE `' REGISTERED Y/ N FEE CURREN Address 1034 Skipper Ro , Tampa, FL 33613 License# EC13005408 PLUMBER ., COMPANY Bayonet Plumbing, Heating &AC, Inc SIGNATURE REGISTERED Y/ N FEE CURREN I Y/N Address P.O. Box 5308, BEI Onet, FL 34674-5308 License# I CFC042998 MECHANICAL COMPANY Bayonet Plumbing, Heating &AC, Inc SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address P.O. Box 5308, Bayonet, FL 34674-5308 License# I CAC058062 007 OTHER _7COMPANY SIGNATURE --�_ REGISTERED Y/ N FEE CURREN Address 4211 Shoal Line Blvd, Spring Hill, FL 34607 License# CCC057991 1111111111111111111111111111111111111111111111111111111111111111111 RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. i i i i i i i i i i i i a Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500) ** Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles- Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may bm subject ^restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with on' applicable deed restrictions. ` UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired n contractor or contractors to undertake xxork, they may be required to be |imanoad in accordance with state and local nagu|sdinno. If the contractor is not licensed as required by |avv, both the owner and contractor may be cited for misdemeanor violation under state |mw. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or onntnootono, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contraotor, that may ba an indication that haia not properly licensed and is not entitled to permitting privileges in Pasco County, TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing bui|dinge, as specified in Pasco County Ordinance number 89-07 and 90'07. an emended. The undersigned also understondo, that such feeo, as may be dum, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving o "certificate of occupancy" or final power release. |f the project does not involve a certificate of occupancy or final power re|eaae, the fees must be paid prior to permit issuance. Furthermore, if Pasco CoUntyVVater/Sewar Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713. Florida Statutes, aaamnendmd): |f valuation of work io $2.500.0Oormore, | certify that |, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver ithn the"mwner" prior tocommencement. CONTRACTOFX`GIOWNER'SAFF|[lAV|T: | certify that all the information in this application is accurate and that all work will be dona in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. ) certify that no work or installation has commenced prior to issuance of permit and that all work will be performed to meet standards of all |ewo regulating construction, County and City- nodeo, zoning regulations, and land development regulations (n the jurisdiction. | also certify that | understand that the regulations of other government agencies may apply to the intended work, and that it is rny responsibility to identify what actions| must take tobeincompliance. Such agencies include but are not limited to: ' Department of Environmental Protection-Cypress Bmyheedo. Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. - Southwest Florida VVsder Management Oiothot4AAeUo, Cypress Boyheodo, Wetland Areas. Altering Watercourses. ' Army Corps ofEngineen*GaswvaUs. Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-VVe||a, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. ' Federal Aviation Authorih/-Runwayo. | understand that the following restrictions apply ho the use offill: - Use of fill in not allowed in Flood Zone Wr unless expressly permitted. ' If the fill material is to be used in Flood Zone 'YY', it is understood that drainage plan addressing o "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State ofFlorida. ' \f the fill material is to be used in Flood Zone ^K in connection with e permitted building using stem xvaU construction, I certify that fill will be used only to fill the area within the stem wall, - If fill material in to be used in any area. | certify that use of such UU will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots |eon than one (1) acre which are elevated by fill, an engineered drainage plan |orequired. If| am the AGENT FOR THE OWNER, | promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. | understand that a meponahs permit may be required for electrical vVork, p\umbing, nigno, vveUn, poo|e, air conditioning, gms, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority toviolate, nanoe|, a|ter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension may be requested, in vvriUng, from the Building Official for a period not to smooad ninety (90) days and will demonstrate justifiable cause for the extension, |f work ceases for ninety(8O)consecutive days,the job |o considered abandoned. WARNING TO OWNER: YOUR E&}UJRE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND T0OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. OWNER OR AGENT 4 CONTRACTOR Subscribed and sworn to(or affirmed fore me this Subscribed and sworn to(or Armed)before me this Who is/are personally known to me s(r#asA4av--pFGdWGed is/are personally known to me or hasihave as identification. as identiiic-a-tio'n- otaryPumm _Notary Public Commission No. FF98537 Commission No. FF98537 Eli000M.Holleran IDioau8&.Holleran N00�\0U 0UNN Rec` %0.mm ^ 2018053289 ' : m'm= . ~--'0 00 ^, �� m�" ' K. �. , -_ ' ______ ' ^� mmty ��� - -'-' uc��n��� pouLn a.o'wsn-.m`o.pnsoo c��x^ .4/m2/20 OR ~~ p =� ~~ i '- ------ PonnxNu perceImwo 05-26-21-0070-00400-0180 NOTICE OF COMMENCEMENT State of Florida county of Pasco UNDERSIGNEDTHE hereby givesnoncematimpm"emmmvwUbemadomoomamma|pmvcrty,omx|nommrdamoewithohapter713.Roridu8tatumo. the foUmwting information io provided in this Notice mCommencement: . I. Description ufProperty: La8d SILVERADO RANCH SUBDIVISION PHASES 2,3,&4 PB 73 PG 59 BLOCK 04 LOT 18 ' Street Address: 6671 Paden Wheel Street Zephryhills FIL 33541 Single Family Residence/Pool/Screen Enclosure Fence �� oonem\000no�ionvf|mpmvemnn� ''y" ' n. Owner Information: LennorHumes LLC Name 4600 W Cypress St, Ste 200 Tampa F[. 33GO7 Address city State Interest inProperty: Name m Fee Simple Titleholder: N/A (if other than owner) Address city State 4. Contractor: Le/x/ 4600 W Cypress St, Ste 200 Tampa Name FL33807 Address city State Contrac tor's 813 Telephone -574.67DO u Surety: Name Address city State - Amount o,Bond: Telephone No.: 6. Lender: m Address City State Lender's Telephone mu: r Persons Within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by eoommr1n1o(1)($pq.Florida Statutes: Name ' Address City State ' Telephone Number of Designatedm 813 Pm Person: .574.57OO B. m addition m himself,the owner designates cf____ to receive a copy of the Lienor's Notice as provided in Section 713.13(l)(b),Florida Statutes. Telephone Number mr Person v,Entity Designated uyOwner: ' 9. Expiration date of Notice nfCommencement is one year from the date of recording unless o different date|»specified: WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN AfTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. STATE OrFLORIDA COUNTY oFp|NsLu\a Signature o;Owner nr Owner's Authorized 0noer/omectnr/pouoer/munagm Vice President Signatory's The foregoing instrument was acknowledged before me'this-6 day of March —by Steve Robert Smith as Vice President (type of authority,',e.g.,officer,trustee,attorney in fact)for Lennar Homes, LLC fnameofp_arty on alf of instrument was executed). Sic Pe rsonally Known N OR Produced Identification El Nota Type of Identification Produced Name(Print) EU88GMOU8rGO . Verification pursuant-to Section 92.525,Florida Statutes. Under penalties of perjury,|declare that|have mad the foregoing and that the facts stated in ' x are true tome'6,o 6��� and belief.: � ., ' - ^ HOLLERAW �gnumemwom�/pumvno�nmeAuu,e - tLISS . ' . #FF 085637 � form, ---- ��IE OF FLOROA,COUNTY OF PASCO THIS IS TO CERTIFY'THAT THE FOREGOING IS A � TRUE AND CORRECT COPY OF THE DOCUMENT 41 ON FILE OR OF PUBLIC RECORD IN THIS OFFICE gave O .'WITNESS MY HAND AND OFkCIAL SEAL THIS DAY OF 2_ o ta PAULA.S.O'NEIL, L IRK&COMPTROLLER iS 7 BY 11'aA-Ai DEPUTY CLERK OF City ofZephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: �%� '� ' Date Received: Site: Permit Type: Si Yl )Z1 Approved w/no comments:❑ Approved w/the below comments: Denied w/the below comments: ❑ i i This comment sheet shall be inept with the permit and/or plans. � - WLL'11-1— i Kalvin Switzer—Plans Examiner Date Contractor and/or Homeowner (Required when comments are present) Lennar Homes-6671 Paden Wheel St-5,491 sq ft Column ts SQ. FEET PRICE MAIN OR LIVING: 5,491 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 618,561.15 FEE SHEET $ 1,926.00 ADDRESS $ 40.00 DRIVEWAY $ 40.00 I BUILDING: $ 2,044.52 ELECTRICAL: $ 433.35 PLUMBING: $ 288.90 MECHANICAL: $ 202.23 SUB-TOTAL $ 2,969.00 TOTAL $ 2,969.00 SEWER: n/a WATER: n/a IRRIGATION: $ - TOTAL: $ - WATER METER: n/a IRRIGATION METER $ - I FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - I PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 3,522.35 PARK IMPACT FEES $ 769.56 SIF'S: $ 4,828.00 100.0% $ 4,828.00 1.0% $ 48.28 TOTAL: $ 4,876.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 12,800.19 6671 Paden Wheel St. Column Es SO. FEET PRICE UNDER ROOF: 5,491 $ 112.65 OTHER: VALUATION $ 618,561.15 FEE SHEET $ 1,926.00 ADDRESS $ 40.00 DRIVEWAY $ 40.00 BUILDING: $ .2,044.52 ELECTRICAL: $ 433.35 PLUMBING: $ 288.90 MECHANICAL: $ 202.23 SUB-TOTAL $ 2,969.00 TOTAL $ 2,969.00 SEWER: WATER: IRRIGATION: $ - TOTAL: $ - WATER METER: IRRIGATION METER FIRE DEPARTMENT FEES PLANS TOTAL: INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 3,522.35 PARK IMPACT FEES $ 769.56 SIF'S: $ 4,828.00 100.0% $ 4,828.00 1.0% $ 48.28 TOTAL: $ 4,876.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 121800.19 05-26-21-0070-00400-0.180 Pasco County Property Appraiser Page 1 of 1 Data Current as Of: Weekly Archive - Saturday, March 24, 2018 Parcel ID 05-26-21-0070-00400-0180 (Card: 001 of 001) Classification 00 - Vacant Residential Mailing Address Property Value LENNAR HOMES LLC Ag Land $0 4600 W CYPRESS ST STE 200 Land $27,016 TAMPA FL 33607-4099 Building $0 Physical Address Extra Features $0 6671 PADEN WHEEL STREET ZEPHYRHILLS, FL 33541 Just Value $27,016 Legal Description (First 4 Lines) Assessed (Non-School Amendment 1) $27,016 SILVERADO RANCH SUBDIVISION PHASES 2, 3 &4 PB 73 PG 059 BLOCK 4 Taxable Value $27,016 LOT 18 Jurisdiction City of Zephyrhills Land Detail (Card: 001 of 001) Line juse Descript_ioniZoning iunits Type lPrice Condition !Value_ T 1 _ 0100 SFR_� MPUD 6,000.00 SF $4.40 1.00 $26,400 2 0100 SFR MPUD 1,539.00 SF $616 Additional Land Information _ Acres I 0.17 iTax Areal 30SI FEMA f Residential Code j SLVRCPI Code i Building Information - Use 00 - Unimproved (Card: 001 of 001) Unimproved Parcel 00 - Unimproved Extra Features (Card: 001 of 001) _ Line Description lYear Units _ �Value No Extra Features Sales History- See All 6 sales Previous Owner: DUNE FL LAND I SUB LLC Month/Year_ Book/Page Type _ �DOR Code Condition �►mount�� 03/2018 9694 / 3124 Warranty Deed I�05 _ Vacant Multi Parcel Sale 09/2011 ( 8606 / 3376 Warranty Deed 05 Vacant Multi-Parcel-Sale 05/2010 8373 / 1912 Certificate of Title j 12 Vacant $0 I i http://search.pascopa.com/parcel.aspx?parcel=2126050070004000180 4/2/2018 Single Family Dwelling Pl an Review Comments 1. F.F.E. shall be a minirnum of.8"above the road elevation and an engineered site plan. I. 'Lots"shall be-graded.to comply with R401.3 of the F.B.C. 3. Compaction-test required.if 24" or more of fill dirt is brought in at any one place: 4:. :Tie in survey required before pouring concrete.. . .. 5. "Driveways:require a R.-O.W. use permit: All.4 sides of driveway."thru the sidewalk shall have expansion material.. 6. All setbacks shall be met... . .7. All property markers"shall be,uncovered and marked at time of first:inspection: 8: " All A.D.A:requirements shall be met.:'- 9.. "No electric;plumbing,-mechanical; or-framing shall b,e covered without an-inspection.and :approval first. . l0.All Garages shall comply with section R302:6.of the F.B.C...(Fire Separation). 11.Appliances"shall not:be installed in a location where subject to"rechanical darriage unless protected:by approved barriers. "M303.4 of the F.B.C. 12. Water heaters shall comply with section P607.3 of the F.B.C: 13. Foundation supports for'A/C.units shall be raised at least 37 above finished grade..' M13-08.i. 14. Return air in all,bedrooms.T.B.C. M1620.4,. . 15. Smoke detectors'are.to-be installed:in accordance with:R313:.1 of the F.B.C. 16.-All_glazing requirements are:.to be m accordance-with R308.4,of the.F.B.C. 17. All means of egress are to.be in accordance with.R311'6f the RB.C..:: 18.-`,'Green gypsum board"-shall not be used:as.a backer.in:showers or tubs. R702.4.2 F.B.C. 19. Combination-t ype AFCI breakers are required_at all locations re.quirm n AFCI-type Breaker: 20. Carbon monoxide alarms"will be required in.now:construction that uses fossil-burniri e'atin or appliances"or an attached garage: They shall be,installed in accordance"with_the F;B.C. 21. All plumbing;mechanical,"and electrical shall be separate from unit to unit: This includes all. underground plumbing and electric: - 22. All2008 N".E:C: Codes.will.'be enforced. 23. Tamper-Resistant Receptacles in accordance with 406.11 of"the 2"008 N.E:G .24. In"accordance:.with the Land.Development:Code;.lots shall be sodded before final at least 10 feetaround the.structure: 25.A.copy of the energy cacls shall be.with permit at all times. .26..Copy of final insulation report shall be.provided with.permit_before.lnah . F:F:E.-Finished Floor Elevation F.B.C-_Florida Building Code"5 . Edition R.O.W.-Right of Way A.D.A.-Americans with Disabilities Act NI.C.-National Electric Code(2008) : - - PAD 1107.8` 4 f TYPE B, JJ \ oa$ t '/ 7D' i{,'jy ttr •t�• :r' y7;p ��\ :�{ � „�bc r �. � `tip r o _ _ {; tk• P• r '� t7 �ti d ix r 1 '1 1q a a �'; �+?°•, i- �3FF=i08:7,0:•L+ r ,t'` pp -r it U Lt7T 1�''1 O ' r ��. ,,� f��.•` -`",�bt (Jr.76 - '.!• .93a - 4 TYP. %$ - _ \ \ ref$ -;� 117T`3 ' .iy10;! p. y fi. ,a1 fi / '`� .4 ,,�a• t� •tI Z.,} a 9 t_!F�108a90 `J`\� � f ¢4 . l"4\ vC' 4%6 N ^ r \q PAD=1a8:2 -PAD=1�08.2. �' t / TYRE A ` TYF�` .8 0 ' �q C + cG r t O�° Jtq� r FF=109.20 FF=t Oi D' 'ti r + , , LOT 6 \ �� - ,o PAD=108.5 8• _ _ FF=109.80 LOT" t TYPE A ,PAD=108.3 h. !. r 4 4 D TYPE B J �� �;. q n 10 a TY pk ` 'i d- gyp•': + 1 ` FF=1b4M 1+ t�'r a7 63 4 \ ' t I FF 109.60 LOT 7 t o , LOT. 14' i $ Pqp=108.9 r # 3 $ PAD=108.5 t 'j ? P,E A o 0VIM ,r TYPE;8 I I 1 FF=109.90 t LOT 3 PAD=109.2 > $' TYPE A 7 �. f1q$' .. FF=109.40 1 is PAD=108 7 ll I FF-1.1Y8� `. 1q >'` o i TYPE 8 q \q Its 1� PADfl9 3 ' t� $ ti�yb' py� ©Cj TYPE A 90 FF=109176 q n FF-109� n. 1[1`f rr-ono nri n i si FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method 0418 Project Name: 4259AB sf ADS Builder Name: Lennar Homes Street: 6671 Paden Wheel Street Permit office: �ty Of,Zephyrhills City,State,Zip: ,FL, Permit Number: o Owner: Lennar Homes Jurisdiction: 611600 Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(4117.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1874.70 ftz b.Concrete Block-Int Insul,Exterior R=4.1 1682.30 ftz 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 560.00 ftz 4. Number of Bedrooms 6 d.N/A R= ftz 10.Ceiling Types (2499.0 sqft.) Insulation Area 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 2347.00 ftz 6. Conditioned floor area above grade(ftz) 4259 b.Knee Wall(Vented) R=30.0 152.00 ftZ Conditioned floor area below grade(ftz) 0 c.N/A R= ft2 11.Ducts R ftz 7. Windows(518.7 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 469.4 a. U-Factor: Dbl,U=0.54 298.01 ftz b.Sup: 1st Floor,Ret:2nd Floor,AH:2nd Floor 6 382.4 SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.56 98.69 ftz 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.28 a.Central Unit 25.2 SEER:16.00 j b.Central Unit 30.0 SEER:15.00 c. U-Factor: Dbl,U=0.58 72.00 ftz SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency d. U-Factor: other(see details) 50.00 ftz a.Electric Heat Pump 21.8 HSPF:8.50 SHGC: other(see details) b.Electric Heat Pump 26.0 HSPF:8.50 Area Weighted Average Overhang Depth: 4.720 ft. Area Weighted Average SHGC: 0.305 14.Hot water systems a.Electric Cap:40 gallons 8. Floor Types (4259.0 sqft.) Insulation Area EF:0.950 a.Floor Over Other Space R=0.0 2060.00 ftz b. Conservation features b.Slab-On-Grade Edge Insulation R=0.0 1912.00 ftz None c.other(see details) R= 287.00 ftz 15.Credits Pstat Glass/Floor Area: 0.122 Total Proposed Modified Loads: 120.59 PASS Total Baseline Loads: 122.51 I hereby certify that the'plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance ��+,,;, a,��,�: Dave with the Florida Energy Code. D 1. iiii " ='.';•�``��, 0, PREPARED BY: Gh Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 * ' I herebycertify that this building,as des ned, is'n compliance Florida Statutes. ; fy 9. 9 P with the Florida Energy Code. OWNER/AGENT: BUILDING OFFICIAL: DATE: L2 DATE: I - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with Section 803 of RESNET Standards,is not greater than 0.080 Qn for whole house. 7/27/2017 2:42 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project'Name: 4259AB sf ADS Builder Name: Lennar Homes 0418 Street: 6671 Paden Wheel Street Permit office: City of Zephyrhills City,State,Zip: FL, Permit Number: Owner: Lennar Homes Jurisdiction: 611600 Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(4117.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1874.70 ftz b.Concrete Block-Int Insul,Exterior R=4.1 1682.30 ftz 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 560.00 ftz 4. Number of Bedrooms 6 d.N/A R= ftz 5. Is this a worst case? Yes 10.Ceiling Types (2499.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 2347.00 ftz 6. Conditioned floor area above grade(ftz) 4259 b.Knee Wall(Vented) R=30.0 152.00 ftz Conditioned floor area below grade(ftz) 0 c.N/A R= ftz 11.Ducts R ftz 7. Windows(518.7 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 469.4 a. U-Factor: Dbl,U=0.54 298.01 ftz b.Sup: 1st Floor,Ret:2nd Floor,AH:2nd Floor 6 382.4 SHGC: SHGC=0.31 b. U-Factor. Dbl,U=0.56 98.69 ftz 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.28 a.Central Unit 25.2 SEER:16.00 c. U-Factor: Dbl,U=0.58 72.00 ftz b.Central Unit 30.0 SEER:15.00 SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency d. U-Factor: other(see details) 50.00 ftz a.Electric Heat Pump 21.8 HSPF:8.50 SHGC: other(see details) b.Electric Heat Pump 26.0 HSPF:8.50 Area Weighted Average Overhang Depth: 4.720 ft. Area Weighted Average SHGC: 0.305 14.Hot water systems 8. Floor Types (4259.0 sqft.) Insulation Area a.Electric Cap:40 gallons a.Floor Over Other Space R=0.0 2060.00 ftz b. Conservation features EF:0.950 b.Slab-On-Grade Edge Insulation R=0.0 1912.00 ftz None c.other(see details) R= 287.00 ftz 15.Credits Pstat Glass/Floor Area: 0.122 Total Proposed Modified Loads: 120.59 PASS Total Baseline Loads: 122.51 I hereby certify that the plans and specifications covered by Review of the plans and 4 Tk1E:ST�j?, this calculation are in compliance with the Florida Energy specifications covered by this = Code. calculation indicates compliance �ave (��lGl'l with the Florida EnergyCode. PREPARED BY: Before construction is completed DATE: this buildingwill be inspected for P compliance with Section 553.908 *, hereby certify that this building,as designed, is in compliance Florida Statutes. ; with the Florida Energy Code. �'Op �� OWNER/AGENT: BUILDING - FFICIAL: DATE: DATE: 0i I - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with Section 803 of RESNET Standards, is not greater than 0.080 Qn for whole house. 7/27/2017 2:42 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method 0418 Project Name: 4259AB sf ADS BuilderName: Lennar Homes Street: 6671 Paden Wheel Street Pemit office: City of Zephyrhilis City,State,Zip: FL, Permit Number: Owner: Lennar Homes Jurisdiction: 611600 Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(4117.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1874.70 ft2 b.Concrete Block-Int Insul,Exterior R=4.1 1682.30 ft2 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 560.00 ft2 4. Number of Bedrooms 6 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (2499.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 2347.00 ft2 6. Conditioned floor area above grade(ft2) 4259 b.Knee Wall(Vented) R=30.0 152.00 ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(518.7 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 469.4 a. U-Factor: Dbl,U=0.54 298.01 ft2 b.Sup: 1st Floor,Ret:2nd Floor,AH:2nd Floor 6 382.4 SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.56 98.69 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.28 a.Central Unit 25.2 SEER:16.00 b.Central Unit 30.0 SEER:15.00 c. U-Factor: Dbl,U=0.58 72.00 ft2 SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency d. U-Factor: other(see details) 50.00 ft2 a.Electric Heat Pump 21.8 HSPF:8.50 SHGC: other(see details) b.Electric Heat Pump 26.0 HSPF:8.50 Area Weighted Average Overhang Depth: 4.720 ft. j Area Weighted Average SHGC: 0.305 14.Hot water systems 8. Floor Types (4259.0 sqft.) Insulation Area a.Electric Cap:40 gallons a.Floor Over Other Space R=0.0 2060.00 ft2 b. Conservation features EF:0.950 b.Slab-On-Grade Edge Insulation R=0.0 1912.00 ft2 None c.other(see details) R= 287.00 ft2 15.Credits Pstat Glass/Floor Area: 0.122 Total Proposed Modified Loads: 120.59 PASS Total Baseline Loads: 122.51 01 I hereby certify that the plans and specifications covered by Review of the plans and 'C this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance /Ii•• %gip� � �J�G� with the Florida Energy Code. F+° rim :r. • , , Dave PREPARED BY: Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 I hereby certify that this building,as designed, is in compliance Florida Statutes. .� with the Florida Energy Code. COrjv OWNER/AGENT: BUILDING OF ICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in'accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with Section 803 of RESNET Standards,is not greater than 0.080 Qn for whole house. 7/27/2017 2:42 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2014 PROJECT Title: 4259AB sf ADS Bedrooms: 6 Address Type: Street Address Building Type: User Conditioned Area: 4259 Lot# Owner: Lennar Homes Total Stories: 2 Block/SubDivision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: Lennar Homes Rotate Angle: 315 Street: Permit Office: Cross Ventilation: No County: Pasco Jurisdiction: Whole House Fan: No City,State,Zip: , Family Type: Single-family FL, New/Existing: New(From Plans) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Tampa FL_TAMPA_INTERNATI 2 39 91 70 75 645.5 54 Medium BLOCKS Number Name Area Volume 1 Block1 1912 17781.6 2 Block2 2347 18776 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 1st Floor 1912 17781.6 Yes 1 1 1 Yes Yes Yes 2 2nd Floor 2347 18776 No 6 5 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Floor over Garage 2nd Floor --e ---- 287 ft2 11 0.5 0 0.5 2 Slab-On-Grade Edge Insulatio 1st Floor 233 ft 0 1912 ft2 -- 0.3 0 0.7 3 Floor Over Other Space 2nd Floor --_ ---- 2060 ft2 0 0.2 0 0.8 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 2625 ft2 0 ft2 Medium 0.85 No 0.9 No 0 26.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 2347 ft2 N NA, 7/27/2017 2:42 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5 1 ' / FORM R405-2014 CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) 1 st Floor 30 Blown 2347 ft2 0.1 Wood 2 Knee Wall(Vented) 2nd Floor 30 Batt 152 ft2 0.11 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing- Solar Below# Ornt To Wall Type R-NIA-le Ft In Et In Area R-1halue Fraction Absor Grade% 1 N=>NW Exterior Concrete Block-Int Insul 1st Floor 4.1 18 2 9 4 169.6 ft2 0 0 0.6 0 2 S=>SE Exterior Concrete Block-Int Insul 1st Floor 4.1 35 4 9 4 329.8 ft2 0 0 0.6 0 3 E=>NE Exterior Concrete Block-Int Insul 1st Floor 4.1 25 0 9 4 233.3 ft2 0 0 0.6 0 4 W=>SW Exterior Concrete Block-Int Insul 1st Floor 4.1 68 9 4 634.7 ft2 0 0.6 0 5 E=>NE Garage Frame-Wood 1st Floor 11 40 0 9 4 373.3 ft2 0.23 0.01 0 6 N=>NW Exterior Frame-Wood 2nd Floor 11 50 0 8 400.0 ft2 0.23 0.6 0 _7 S=>SE Exterior Frame-Wood 2nd Floor 11 35 4 8 0 282.7 ft2 0.23 0.6 0 8 W=>SW Exterior Frame-Wood 2nd Floor 11 55 3 8 0 442.0 ft2 0.23 0.6 0 9 E=>NE Exterior Frame-Wood 2nd Floor 11 67 8 0 536.0 ft2 0.23 0.6 0 10 S=>SE Exterior Concrete Block-Int Insul 1 st Floor 4.0999 14 9 9 4 137.7 ft2 0 0.600000 0 11 N=>NW Garage Frame-Wood 1 st Floor 11 20 9 4 186.7 ft2 0 0.01 0 12 W=>SW Exterior Frame-Wood 2nd Floor 11 12 8 96.0 ft2 0 0.600000 0 i 13 S=>SE Exterior Frame-Wood 2nd Floor 111 14 9 8 118.0 ft2 0 0.600000 0 14 N=>NW Exterior Concrete Block-Int Insul 1st Floor 4.0999 11 8 9 4 108.9 ft2 0 0.600000 0 15 N=>NW Exterior Concrete Block-Int Insul 1st Floor 4.0999 7 4 9 4 68.4 ft2 0 0.600000 0 � DOORS # Ornt Door Type Space Storms U-Value Width Height Area I Ft In Ft In 1 N=>NW Insulated 1st Floor None .2 3 6 8 20 ft2 2 E=>NE Wood 1st Floor None .4 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered orientation => changed to Worst Case. / Will Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 S=>SE 2 Metal -Low-E Double Yes 0.54 0.31 32.0 ft2 1 ft 0 in 10 ft 4 in Drapes/blinds Exterior 5 2 N=>NW 1 Metal Low-E Double Yes 0.56 0.28 23.0 ft2 12 ft 4 in 0 ft 2 in Drapes/blinds Exterior 5 3 N=>NW 14 Metal Low-E Double Yes 0.56 0.28 23.0 ft2 1 ft 0 in 10 ft 4 in None Exterior 5 4 N=>NW 15 Metal Low-E Double Yes 0.54 0.31 6.3 ft2 6 ft 0 in 2 ft 0 in Drapes/blinds Exterior 5 5 W=>SW 4 Metal Low-E Double Yes 0.54 0.31 69.0 ft2 1 ft 0 in 10 ft 4 in Drapes/blinds Exterior 5 6 S=>SE 10 Metal Low-E Double Yes 0.58 0.32 72.0 ft2 12 ft 0 in 0 ft 3 in Drapes/blinds None 7 E=>NE 9 Metal Low-E Double Yes 0.54 0.31 12.0 ft2 1 ft 0 in 0 ft 8 in Drapes/blinds Exterior 5 8 S=>SE 7 Metal Low-E Double Yes 0.54 0.31 16.0 ft2 1 ft 0 in 0 ft 8 in Drapes/blinds Exterior 5 9 S=>SE 7 Metal Low-E Double Yes 0.54 0.31 46.0 ft2 1 ft 0 in 0 ft 8 in Drapes/blinds Exterior 5 10 S=>SE 13 Metal Double(Clear) Yes 0.27 0.3 33.3 ft2 10 ft 0 in 0 ft 8 in None None � 11 W=>SW 12 Metal Low-E Double Yes 0.27 0.3 16.7 ft2 14 ft 9 in 0 ft 8 in Drapes/blinds Exterior 5 12 W=>SW 12 Metal Low-E Double Yes 0.54 0.31 23.0 ft2 14 ft 9 in 0 ft 4 in Drapes/blinds Exterior 5 13 W=>SW 8 Metal Low-E Double Yes 0.54 0.31 16.0 ft2 1 ft 0 in 0 ft 8 in Drapes/blinds None 7/27/2017 2:42 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2014 WINDOWS Orientation shown is the entered orientation => changed to Worst Case. Wall Overhang # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 14 N=>NW 6 Metal Low-E Double Yes 0.56 0.28 23.0 ft2 1 ft 0 in 0 ft 8 in Drapes/blinds Exterior 5 15 N=>NW 6 Metal Low-E Double Yes 0.56 0.28 17.7 ft2 1 ft 0 in 0 ft 8 in Drapes/blinds Exterior 5 16 N=>NW 6 Metal Low-E Double Yes 0.56 0.28 12.0 ft2 1 ft 0 in 0 ft 8 in Drapes/blinds None 17 E=>NE 9 Metal Low-E Double Yes 0.54. 0.31 48.0 ft2 1 ft 0 in 0 ft 8 in Drapes/blinds None 18 W=>SW 8 Metal Low-E Double Yes 0.54 0.31 6.7 ft2 1 ft 0 in 0 ft 8 in None None 19 S=>SE 2 Metal Low-E Double Yes 0.54 0.31 23.0 ft2 1 ft 0 in 10 ft 4 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 722 ft2 722 ft2 61 ft 9.3 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000382 4265.1 234.15 440.35 .3525 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump None HSPF:8.5 21.8 kBtu/hr 1 sys#1 2 Electric Heat Pump None HSPF:8.5 26 kBtu/hr 2 sys#2 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 16 25.2 kBtu/hr 756 cfm 0.85 1 sys#1 2 Central Unit Split SEER: 15 30 kBtu/hr 900 cfm 0.85 2 sys#2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 40 gal 60.9 gal. 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 I i 7/27/2017 2:42 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 FORM R406-2014 DUCTS / —Supply— —Return— Air CFM 25 CFM25 HVAC# �/ # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 469.4 ft 2nd Floor 117.35 Proposed Qn 2nd Floor —cfm 153.0 cfm 0.08 0.60 1 1 2 1st Floor 6 382.4 ft 2nd Floor 95.6 ft' Proposed Qn 2nd Floor —cfm 187.8 cfm 0.08 0.60 2 2 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Coolin [ ]Jan [ ]Feb [ ]Mar [ ]A r [ IM a rj Jun rl Jul ri Au ri Se [ ]Oct Nov Dec Heating [X]Jan [X]Feb [X]Mar [ ]Apr [ MaY Jun Jul Au Sep [ ]Oct Nov Dec Ventin [ ]Jan [ ]Feb [[X]Mar [X]A r [ May Jun Jul Aug Se [X]Oct HX Nov H Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MECHANICAL VENTILATION Type Supply CFM Exhaust CFM Fan Watts HRV Heating System Run Time Cooling System None 0 0 0 1 -Electric Heat Pump 0% 1 -Central Unit None 0 0 0 2-Electric Heat Pump 0% 2-Central Unit I 7/27/2017 2:42 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the EnergyPerformance Index, the more efficient the home. FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1874.70 ft2 b.Concrete Block-Int Insul,Exterior R=4.1 1682.30 ft 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 560.00 ft2 4. Number of Bedrooms 6 d.N/A R= ft2 10.Ceiling Types Insulation Area 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 2347.00 ft2 6. Conditioned floor area(ft2) 4259 b.Knee Wall(Vented) R=30.0 152.00 ft2 _ 2 7. Windows" Description Area 11. .N/Aucts R R ft2 a. U-Factor: Dbl,U=0.54 298.01 ft2a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 469.4 SHGC: SHGC=0.31 b.Sup: 1st Floor,Ret:2nd Floor,AH:2nd Floor 6 382.4 b. U-Factor: Dbl,U=0.56 98.69 ft2 SHGC: SHGC=0.28 12.Cooling systems kBtu/hr Efficiency c. U-Factor: Dbl,U=0.58 72.00 ft2 a.Central Unit 25.2 SEER:16.00 SHGC: SHGC=0.32 b.Central Unit 30.0 SEER:15.00 d. U-Factor: other(see details) 50.00 ft2 13.Heating systems kBtu/hr Efficiency SHGC: other(see details) a.Electric Heat Pump 21.8 HSPF:8.50 Area Weighted Average Overhang Depth: 4.720 ft. b.Electric Heat Pump 26.0 HSPF:8.50 Area Weighted Average SHGC: 0.305 8. Floor Types Insulation Area 14.Hot water systems a.Floor Over Other Space R=0.0 2060.00 ft2 a.Electric Cap:40 gallons EF:0.95 b.Slab-On-Grade Edge Insulation R=0.0 1912.00 ft2 b. Conservation features c.other(see details) R= 287.00 ft2 None 15.Credits Pstat certify that this home has complied with the Florida Energy Efficiency Code for Building T1iE.$r Construction through the above energy saving features which will be installed (or exceeded) ff._ ATAO. in this home before final inspection. Otherwise, a new EPL Display Card will be completed � based on installed Code compliant fe res. ��• ,iii, =; ', o. :� i`�' = .,:•.,.. .'ram Builder Signature: Date: 10/12/17 J Ail Address of New Home: Ci /FL Zi 6671 Paden Wheel Street ty p: ZePhyrhills,FL 33541 i *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 7/27/2017 2:43 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 i BuildingAnalysis Job: 4259AB sf ADS Y Date: 9/2712017 lower floor By: Dave Aldrich Bayonet Plumbing Heating and Cooling 8950 New York ave,Hudson Project • • For: Lennar Homes Design Conditions Location: Indoor: Heating Cooling Tampa International AP, FL, US Indoor temperature(OF) 70 75 Elevation: 10 ft Design TD (OF) 39 16 Latitude: 28°N Relative humidity(%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 34.7 54.7 Dry bulb(OF) 31 91 Infiltration: Daily range(OF) - 14 ( L ) Method Simplified Wet bulb(OF) - 77 Construction quality Semi-tight Wind speed(mph) 15.0 7.5 Fireplaces 0 i Component Btuh/ft2 Btuh % of load Walls 5.6 7481 29.9 ucts Glazing 21.6 5185 20.7 Doors 23.5 466 1.9 wan nfiltraton Ceilings 2.9 73 0.3 Floors 3.5 6649 26.6 Infiltration 1.9 3055 12.2 Ducts 2088 8.4 Piping 0 0 Floors Humidification 0 0 Glazing Ventilation 0 0 other Adjustments 0 Total 24996 100.0 I Component Btuh/ft2 Btuh % of load Walls 2.8 3721 18.7 Glazing 38.8 9328 47.0 Walls Internal Gains Doors 18.4 365 1.8 Ceilings 3.5 88 0.4 Floors 0 0 0 Ducts Infiltration 0.4 661 3.3 Ducts 2396 12.1 Ventilation 0 0 Infiltration Internal gains 3290 16.6 other Blower 0 0 Adjustments 0 Glazing Total 19850 100.0 Latent Cooling Load=2394 Btuh Overall U-value= 0.143 Btuh/ft2-°F Data entries checked. - 1- wrightsoft9 2017-Sep-27 06:59:52 Right-Suite®Universal 2017 17.0.23 RSU05714 Page 1 ..A27UHE AH's\4259AB sf ADS template 2.5-2ton.rup Calc=MJB Front Door faces:SE Building Analysis Job: 4259AB sf ADS g Y Date: 9/2712017 upperfloor By: Dave Aldrich Bayonet Plumbing Heating and Cooling 8950 New York ave,Hudson Project • • For: Lennar Homes Design Conditions Location: Indoor: Heating Cooling Tampa International AP, FL, US Indoor temperature(OF) 70 75 Elevation: 10 ft Design TD (OF) 39 16 Latitude: 280N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 34.7 54.7 Dry bulb(°F) 31 91 Infiltration: Daily range(OF) - 14 ( L ) Method Simplified Wet bulb(OF) - 77 Construction quality Semi-tight Wind speed(mph) 15.0 7.5 Fireplaces 0 Component Btuh/ft2 Btuh % of load Walls 3.8 6008 29.1 Ducts Glazing 19.4 5191 25.1 wall Doors 0 0 0 Ceilings 1.3 2944 14.3 nfiltration Floors 2.0 18 0.1 I Infiltration 1.9 3540 17.1 Ducts 2956 14.3 other Piping 0 0 Humidification 0 0 Glazing Ceilings Ventilation 0 0 Adjustments 0 Total 20657 100.0 • • • Component Btuh/ft2 Btuh % of load Walls 2.7 4337 18.7 ntemal Gains Glazing 36.2 9700 41.9 Wall Ducts Doors 0 0 0 Ceilings 1.7 4071 17.6 Infiltration Floors 0.8 8 0.0 Other Infiltration 0.4 765 3.3 t Ducts 3351 14.5 Ventilation 0 0 Internal gains 920 4.0 Ceilings Blower 0 0 ; Adjustments 0 Glazing Total 23152 100.0 Latent Cooling Load= 2989 Btuh Overall U-value= 0.086 Btuh/ft2-°F Data entries checked. - wrightsoft� 2017-Sep-27 06:59:52 Right-Suite®Universal 2017 17.0.23 RSU05714 Page 2 ...A27UHE AH's\4259AB sf ADS template 2.5-2ton.rup Calc=MJ8 Front Door faces:SE Project •7 Summary Job: 4259AB sf ADS Date: 9/27/2017 lower floor By: Dave Aldrich Bayonet Plumbing Heating and Cooling 8950 New York ave,Hudson Project Information For: Lennar Homes Notes: Design Information Weather: Tampa International AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 31 OF Outside db 91 OF Inside db 70 OF Inside db 75 OF Design TD 39 OF Design TD 16 OF Daily range L Relative humidity 50 % Moisture difference 55 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 22909 Btuh Structure 17453 Btuh Ducts 2088 Btuh Ducts 2396 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 24996 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 19850 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 1970 Btuh Ducts 424 Btuh Central vent(0 cfm) 0 Btuh Heatingg Coolin (none) Area(ft2) 1912 10 Equipment latent load 2394 Btuh Volume(ft') 17942 17942 Air changes/hour 0.24 0.12 Equipment Total Load (Sen+Lat) 22244 Btuh Equiv.AVF(cfm) 71 37 Req. total capacity at 0.85 SHR 1.9 ton Heating Equipment Summary Cooling Equipment Summary Make Lennox Make Lennox Trade 14HPX SERIES Trade 14HPX SERIES Model 14HPX-024-230-21 Cond 14HPX-024-230-21 AHRI ref 10258598 Coil CBA27UHE-024-230*++TDR AHRI ref 10258598 Efficiency 8.5 HSPF Efficiency 13.5 EER, 16 SEER Heating input Sensible cooling 21420 Btuh Heating output 21800 Btuh @ 470F Latent cooling 3780 Btuh Temperature rise 25 OF Total cooling 25200 Btuh Actual air flow 800 cfm Actual air flow 800 cfm Air flow factor 0.032 cfm/Btuh Air flow factor 0.040 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.89 Capacity balance point= 35 OF Backup: Input= 7 kW, Output=23020 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft59 ' Right-Suite®Universal 2017 17.0.23 RSU05714 2017-Sep 27 06:Page ge 1 1 ..A27UHE AH's14259AB sf ADS template 2.5-2ton.rup Cale=MJ8 Front Door faces:SE • Job: 4259AB sf ADS Project Summary Date: 9/2712017 upper floor By: Dave Aldrich Bayonet Plumbing Heating and Cooling 8950 New York ave,Hudson Project • • a For: Lennar Homes Notes: Design Information Weather: Tampa International AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 31 OF Outside db 91 OF Inside db 70 OF Inside db 75 OF Design TD 39 OF Design TD 16 OF Daily range L Relative humidity 50 % Moisture difference 55 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 17701 Btuh Structure 19801 Btuh Ducts 2956 Btuh Ducts 3351 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh none Humidification 0 Btuh Blower e) 0 Btuh Piping 0 Btuh Equipment load 20657 Btuh Use manufacturer's data y Ratelswing multiplier 1.00 Infiltration Equipment sensible load 23152 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 2388 Btuh Ducts 601 Btuh Central vent(0 cfm) 0 Btuh Heating coolingg (none) Area(W) 2347 2347 Equipment latent load 2989 Btuh Volume(ft3) 18778 18778 Air changes/hour 0.26 0.14 Equipment Total Load (Sen+Lat) 26141 Btuh j Equiv.AVF (cfm) 82 43 Req. total capacity at 0.85 SHR 2.3 ton Heating Equipment Summary Cooling Equipment Summary Make Lennox Make Lennox Trade 14HPX SERIES Trade 14HPX SERIES Model 14HPX-030-230-21 Cond 14HPX-030-230-21 AHRI ref 10258600 Coil CBA27UHE-030-230*++TDR AHRI ref 10258600 Efficiency 8.5 HSPF Efficiency 13.0 EER, 15 SEER Heating input Sensible cooling 25500 Btuh Heating output 26400 Btuh @ 470F Latent cooling 4500 Btuh Temperature rise 24 OF Total cooling 30000 Btuh Actual air flow 1000 cfm Actual air flow 1000 cfm Air flow factor 0.048 cfm/Btuh Air flow factor 0.043 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.89 Capacity balance point=25 OF Backup: Input= 7 kW, Output=22917 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Wrlg htso t® 2017-Sep-27 06:59:52 ACC "r Right-Suite®Universal 2017 17.0.23 RSU05714 Page 2 ...A27UHE AH's\4259AB sf ADS template 2.5-2ton.rup Calc=MJ8 Front Door faces:SE Manual S Compliance Report Job: 4259AB sf ADS Date: 912712017 lower floor By: Dave Aldrich Bayonet Plumbing Heating and Cooling 8950 New York ave,Hudson Project • • For: Lennar Homes Cooling Equipment Design Conditions Outdoor design DB: 91.3°F Sensible gain: 19850 Btuh Entering coil DB: 75.7°F Outdoor design WB: 77.3°F Latent gain: 2394 Btuh Entering coil WB: 62.9°F Indoor design DB: 75.0°F Total gain: 22244 Btuh Indoor RH: 50% Estimated airflow: 800 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: SplitASHP Manufacturer: Lennox Model: 14HPX-024-230-21+CBA27UHE-024-230*++TDR Actual airflow: 800 cfm Sensible capacity: 21420 Btuh 108% of load Latent capacity: 3780 Btuh 158% of load Total capacity: 25200 Btuh 113% of load SHR: 85% Heating Equipment Design Conditions Outdoor design DB: 30.8°F Heat loss: 24996 Btuh Entering coil DB: 69.6'F Indoor design DB: 70.0*F Manufacturer's Performance Data at Actual Design Conditions Equipment type: SplitASHP Manufacturer: Lennox Model: 14HPX-024-230-21+CBA27UHE-024-230*++TDR Actual airflow: 800 cfm Output capacity: 21800 Btuh 87% of load Capacity balance: 35 °F Supplemental heat required: 3196 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 800 cfm Output capacity: 6.7 kW 92% of load Temp. rise: 50 'F Meets are all requirements of ACCA Manual S. wri htsoft, 2017-Sep-27 06:59:52 9 Right-Suite®Universal 2017 17.0.23 RSU05714 Page 1 14CC�', ...A27UHE AH's14259AB sf ADS template 2.5-2ton.rup Calc=MJ8 Front Door faces:SE Manual S Compliance Report Job: 4259AB sf ADS Date: 912712017 upper floor By: Dave Aldrich Bayonet Plumbing Heating and Cooling 8950 New York ave,Hudson Project • • For: Lennar Homes Cooling Equipment Design Conditions Outdoor design DB: 91.3°F Sensible gain: 23152 Btuh Entering coil DB: 75.7°F Outdoor design WB: 77.3°F Latent gain: 2989 Btuh Entering'coil WB: 62.9°F Indoor design DB: 75.0°F Total gain: 26141 Btuh Indoor RH: 50% Estimated airflow: 1000 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: SpIitASHP Manufacturer: Lennox Model: 14HPX-030-230-21+CBA27UHE-030-230*++TDR Actual airflow: 1000 cfm Sensible capacity: 25500 Btuh 110% of load Latent capacity: 4500 Btuh 151% of load Total capacity: 30000 Btuh 115% of load SHR: 85% Heating Equipment i Design Conditions Outdoor design DB: 30.8°F Heat loss: 20657 Btuh Entering coil DB: 69.6°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: SpIitASHP Manufacturer: Lennox Model: 14HPX-030-230-21+CBA27UHE-030-230*++TDR Actual airflow: 1000 cfm Output capacity: 26000 Btuh 126% of load Capacity balance: 25 °F Supplemental heat required: 0 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 1000 cfm Output capacity: 6.7 kW 111% of load Temp. rise: 50 °F Meets are all requirements of ACCA Manual S. wri htsoft9 2017-Sep-27 06:59:52 �, 9 Right-Suite®Universal 2017 17.0.23 RSU05714 Page 2 14CC3" ...A27UHE AH's14259AB sfADS template 2.5-2ton.rup Calc=MJ8 Front Door faces:SE i I 5335 - 8TH STREET (813)780-0020 i CERTIFICATE OF OCCUPANCY I 1 Address: 6671 PADEN WHEEL ST Owner: LENNAR HOMES LLC ZEPHYRHILLS, FL. 4600 W CYPRESS ST STE 200 Subdiv: SILVERADO TAMPA FL 33607-4099 Parcel: 05-26-21-0070-00400-0180 Work Type: 101-NEW CONST/SFR Construction Type: NOT APPLICABLE ❑ Sprinklers Use Classification: NOT APPLICABLE Permit Number: 19501 Date:,,.,, ;07/2018 � I J ISSUED-By SSU D Y. BUILDI OFFICIAL WATER MUS BE CHANGED OVER WITHIN 10 DAYS OF ISSUANCE GARBAGE DEPOSIT MUST BE APPLIED FOR PRIOR TO.ISSUANCE