Loading...
HomeMy WebLinkAbout18-19502 CITY OF ZEPHYRHILLS 5335-8TH STREET:. (813)780-0020. 19 02 BUILDING PERMIT SINGLE F._AMILY RESIDENTIAL PERMIT INFORMATION LOCATION INFORMATION Permit#:19502 Issued: 4/02/2018 Address: 6582 WAGON TRAIL ST Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Towris.hip: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 256,391.40 Total Fees: 14,145.41 Subdivision: SILVERADO Amount Paid: 14,145.41 Date Paid: 4/03/2018 Parcel Number: 05-26-21-0080-00600-0110 CONTRACTOR INFORMATION OWNER INFORMATION Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC Addr: 4600 W. CYPRESS ST STE 200 Address: 4600 W CYPRESS ST STE 200 TAMPA, FL. 33607 TAMPA FL 33607-4099 Phone: (813)574-5743 Lic: Phone: Work Desc: CONSTRUCT SINGLE FAMILY 2,276 SQ FT APPLICATION-FEES BUILDING FEE 1,426.49 ELECTRICAL FEE 298.13 PLUMBING FEE 198.75 MECHANICAL FEE 139.13 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE-sfr/100% 4,828.00 SCHOOL IMPACT FEE-sfr/1% 48.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32 SCHOOL IMPACT FEE NEW 2,206.68 SCHOOL-SFR NEW 2% 45.04 1 Iw zo� / Inspections Required FOOTER 2ND ROUGH PLUMB misc INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing, consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. 0 � 1 A -,�- beg- fWJ� vC CT SIGNATURE PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER Lennar Homes-6582 Wagon Trail St-2,276 sq ft Column ts SO. FEET PRICE MAIN OR LIVING: 2,276 :$ 112.65 OTHER AREA UNDER ROOF: =:. .$ 88.00 OTHER: - $ - VALUATION $ 266,391.40 FEE SHEET $ 1,326.00 ADDRESS $ 30.00 DRIVEWAY $ 45.00 BUILDING: $ 1,426.60 ELECTRICAL: $ 298.13 PLUMBING: $ 198.76 MECHANICAL: $ 139.13 SUB-TOTAL $ 2,062.50 TOTAL $ 2,062.50 SEWER: n/a WATER: n/a IRRIGATION: $ - TOTAL: $ - WATER METER: n/a IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 2,615.85 PARK IMPACT FEES $ 769.56 SIF'S: $ 4,828.00 100.0% $ 4,828.00 1.0% $ 48.28 TOTAL: $ 4,876.28 T 1 F'S: $ 3,632.00 99% $ 3,596.68 1% $ 36.32 TOTAL: $ 11,893.69 Lennar Homes-6582 Wagon Trail St-2276 sq ft -NEW FEES Column SQ. FEET. . PRICE MAIN OR LIVING: $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ - FEE SHEET ADDRESS DRIVEWAY BUILDING: $ - ELECTRICAL: $ - PLUMBING: $ - MECHANICAL: $ - SUB-TOTAL $ - TOTAL SEWER: n/a WATER: n/a IRRIGATION: $ - TOTAL: $ - WATER METER: n/a IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE FIRE 5% $ - TOTAL: SUB-TOTAL $ - PARK IMPACT FEES SIF'S: $ 2,251.72 100.0% $ 2,206.68 1.0% $ 45.04 TOTAL: $ 2,251.72 balance owe TIF'S : 99% $ - 1% $ - TOTAL: $ 2,251.72 o O City of Zephyrhills y BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: Date Received: Site: 6�76 /ew6 V/ Permit Type: Approved w/no comments:El Approved w/the below comments: CV Denied w/the below comments: ❑ This comment sheet shall be kept with the permit and/or plans. Kalvin Swi -P Examiner Date Contractor and/or Homeowner (Required when comments are present) FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 1791131 sf ADS Builder Name: Lennar Homes Street: 6582 Wagon Trail Street Permit Office: City of Zephyrhills City,State,Zip: Zephyrhills,FL, Permit Number: 1fsez., Owner: Lennar Homes Jurisdiction:611600 Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1572.7 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1241.30 ft2 b.Frame-Wood,Adjacent R=11.0 331.33 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (1817.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1817.00 ft2 6. Conditioned floor area above grade(ft2) 1817 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(143.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 363.4 a. U-Factor: Dbl,U=0.54 87.00 ft2 SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.56 33.33 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 30.0 SEER:15.00 c. U-Factor. Dbl,U=0.56 23.00 ft2 SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 26.0 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 1.233 ft. Area Weighted Average SHGC: 0.308 14.Hot water systems 8. Floor Types (1817.0 sqft.) Insulation Area a.Electric Cap:40 gallons EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 . 1817.00 ft2 b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.079 Total Proposed Modified Loads: 58.14 PASS Total Baseline Loads: 58.15 1 hereby certify that the plans and specifications covered by Review of the plans and afiS]`� this calculation are in compliance with the Florida Energy specifications covered by this ;y . _ qp 01 •, Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: 'Dave Aulich Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 herebycertify that this building,as designed, is in compliance Florida Statutes. fY 9� 9 P with the Florida Energy Code. COJj'y .T OWNER/AGENT: z O18 BUILDING O ICIAL: i DATE: DATE: r - Compliance requires certification by the air hajei unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3. .1. -Compliance requires an Air Barrier and Insulation I pection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.030 Qn for whole house. 2/1/2018 7:07 AM EnergyGaugeO USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 4 S , FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 1791131 sf ADS Builder Name: Lennar Homes Street: 6582 Wagon Trail Street Permit office: City of Zephyrhills City,State,Zip: Zephyrhills,FL, Permit Number: Owner: Lennar Homes ,jurisdiction:611600 Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1572.7 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1241.30 ft2 b.Frame-Wood,Adjacent R=11.0 331.33 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (1817.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1817.00 ft2 6. Conditioned floor area above grade(ft2) 1817 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(143.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 363.4 a. U-Factor: Dbl,U=0.54 87.00 ft2 SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.56 33.33 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 30.0 SEER:15.00 c. U-Factor: Dbl,U=0.56 23.00 ft2 SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 26.0 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 1.233 ft. Area Weighted Average SHGC: 0.308 14.Hot water systems 8. Floor Types (1817.0 sqft.) Insulation Area a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 1817.00 ft2 b. Conservation features EF:0.950 b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.079 Total Proposed Modified Loads: 58.14 PASS Total Baseline Loads: 58.15 I hereby certify that the plans and specifications covered by Review of the plans and .'C1SI,gp, o . this calculation are in compliance with the Florida Energy specifications covered by this 0' Code. calculation indicates compliancef,;,''� aVe (��G with the Florida Energy Code. D PREPARED BY: h Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 herebycertify that this building,as designed,is in compliance Florida Statutes. fY 9� 9 P with the Florida Energy Code. OWNER/AGENT: BUILDING OF ICIAL: DATE: DATE: 2rz i - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.030 Qn for whole house. 2/1/2018 7:07 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 4 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 1791 Bi sf ADS Builder Name: Lennar Homes Street: 6582 Wagon Trail Street Permit office: City of Zephyrhills City,State,Zip: Zephyrhills,FL, Permit Number: Owner. Lennar Homes Jurisdiction:611600 Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1572.7 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1241.30 ftz b.Frame-Wood,Adjacent R=11.0 331.33 ft2 3. Number of units,if multiple family 1 c.N/A R= ftz 4. Number of Bedrooms 4 d.N/A R= ftz 5. Is this a worst case? Yes 10.Ceiling Types (1817.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1817.00 ftz 6. Conditioned floor area above grade(ftz) 1817 b.N/A R= ftz Conditioned floor area below grade(ftz) 0 c.N/A R= ftz 11.Ducts R ftz 7. Windows(143.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 363.4 a. U-Factor: Dbl,U=0.54 87.00 ftz SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.56 33.33 ftz 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 30.0 SEER:15.00 c. U-Factor: Dbl,U=0.56 23.00 ftz SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ftz a.Electric Heat Pump 26.0 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 1.233 ft. Area Weighted Average SHGC: 0.308 14.Hot water systems 8. Floor Types (1817.0.sqft.) Insulation Area a.Electric Cap:40 gallons EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1817.00 ftz b. Conservation features b.N/A R= ftz None c.N/A R= ftz 15.Credits Pstat Glass/Floor Area: 0.079 Total Proposed Modified Loads: 58.14 PASS Total Baseline Loads: 58.15 hereby certify that the plans and specifications covered by Review of the plans and �TH this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: Dave AWch Before construction is completed �. .�riC• �: v DATE: this building will be inspected for compliance with Section 553.908 *, ."$•. :' . hereby certify that this building,as designed,is in compliance Florida Statutes. .� with the Florida Energy Code. OWNER/AGENT: BUILDING O FICIAL: DATE: DATE: i - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house. 2/1/2018 7:07 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 4 FORM R405-2017 PROJECT Title: 1791131 sf ADS Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 1817 Lot# Owner Name: Lennar Homes Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: Lennar Homes Rotate Angle: 45 Street: Permit Office: Cross Ventilation: County: Pasco Jurisdiction: Whole House Fan: City,State,Zip: Zephyrhills, Family Type: Single-family FL, New/Existing: New(From Plans) Comment: CLIMATE J Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Tampa FL_TAMPA_INTERNATI 39 91 70 75 645.5 54 Medium BLOCKS Number Name Area Volume 1 Block1 1817 14536 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1817 14536 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio Main 155 ft 0 1817 ft2 0.3 0 0.7 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1968 ft2 0 ft2 Medium 0.85 No 0.9 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 1817 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) Main 30 Blown 1817 ft2 0.11 Wood 2/1/2018 7:07 AM EnergyGaugeO USA-FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 4 FORM R405-2017 WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 N=>NE Exterior Concrete Block-Int Insul Main 4.0999 19 6 8 156.0 ft2 0 0.600000 0 2 N=>NE Garage Frame-Wood Main 11 20 8 8 165.3 ft2 0 0.01 0 3 W=>NW Garage Frame-Wood Main 11 20 9 8 166.0 ft2 0 0.01 0 4 E=>SE Exterior Concrete Block-Int Insul Main 4.0999 58 8 464.0 ft2 0 0.600000 0 5 S=>SW Exterior Concrete Block-Int Insul Main 4.0999 34 8 272.0 ft2 0 0.600000 0 6 W=>NW Exterior Concrete Block-Int Insul Main 4.0999 37 8 8 301.3 ft2 0 0.600000 0 7 S=>SW Exterior Concrete Block-Int Insul Main 4.0999 6 8 48.0 ft2 0 0.600000 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft, In 1 N=>NE Insulated Main None .2 3 6 8 20 ft2 2 N=>NE Wood Main None .4 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered orientation(=>)changed to Worst Case. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N=>NE 1 Metal Low-E Double Yes 0.56 0.28 N 23.0 ft2 1 ft 0 in 4 ft 0 in Drapes/blinds None 2 E=>SE 4 Metal Low-E Double Yes 0.54 0.31 N 32.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds None 3 S=>SW 5 Metal Low-E Double Yes 0.54 0.31 N 32.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds None 4 S=>SW 7 Metal Low-E Double Yes 0.56 0.32 N 33.3 ft2 2 ft 0 in 0 ft 4 in Drapes/blinds None 5 W=>NW 6 Metal Low-E Double Yes 0.54 0.31 N 23.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 427 ft2 427 ft2 42 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1695.9 93.1 175.09 .2669 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ None HSPF:8.5 26 kBtu/hr 1 sys#1 I 2/1/2018 7:07 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 4 FORM R405-2017 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 30 kBtu/hr 900 cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 40 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS —Supply— —Return— Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 363.4 ft Main 90.85 ft Proposed Qn Main —cfm 54.5 cfm 0.03 0.60 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: CoolingJan Feb Mar Apr May [X Jun [X]Jul rj AugjXj Se [ ]Oct Nov Dec Heatin Jan Feb Mar Apr May [ Jun [ ]Jul [ ]Au Sep [ ]Oct NNov Dec Ventin Jan Feb X Mar A r Ma [ Jun [ ]Jul [ ]Au Se [X]Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 2/1/2018 7:07 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 4 FORM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerformance Index, the more efficient the home. Zephyrhills, FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1241.30 ft2 b.Frame-Wood,Adjacent R=11.0 331.33 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 _ 5. Is this a worst case? Yes 10.Ceiling Types Insulation Area a.Under Attic(Vented) R=30.0 1817.00 ft2 6. Conditioned floor area(ft2) 1817 b.N/A R= ft2 _ 2 7. Windows" Description Area 11 Ducts R R ft2 a. U-Factor: Dbl,U=0.54 87.00 ft2 SHGC: SHGC=0.31 a.Sup:Attic,Ret:Main,AH:Main 6 363.4 b. U-Factor: Dbl,U=0.56 33.33 ft2 SHGC: SHGC=0.32 12.Cooling systems kBtu/hr Efficiency c. U-Factor: Dbl,U=0.56 23.00 ft2 a.Central Unit 30.0 SEER:15.00 SHGC: SHGC=0.28 d. or: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency SHGC:Area Weighted Average Overhang Depth: 1.233 ft. a.Electric Heat Pump 26.0 HSPF:8.50 Area Weighted Average SHGC: 0.308 8. Floor Types Insulation Area 14.Hot water systems a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 1817.00 ft2EF:0.95 b.N/A R= ft2 c.N/A R= ft2 b. Conservation features None 15.Credits Pstat certify that this home has complied with the Florida Energy Efficiency Code for Building Ttsr Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code c mpliant features. Builder Signature: Date: 02/O1/18 "b)j'' Address of New Home: 6582 Wagon Trail Street City/FL FL 33541 Zip: Zephyrhills,__ *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 2/1/2018 7:08 AM EnergyGauge®USA-FlaRes2017 -Section R405.4.1 Compliant Software Page 1 of 1 Building Analysis Job: 179181 sf ADS g y Date: 211/2018 Entire House By: Dave Bayonet Plumbing Heating and Air Project Information For: Lennar Homes Design C• • • Location: Indoor: Heating Cooling Tampa International AP, FL, US Indoor temperature(OF) 70 75 Elevation: 10 ft Design TD (OF) 39 16 Latitude: 28°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 34.7 54.7 Dry bulb(OF) 31 91 Infiltration: Daily range(0F) - 14 ( L ) Method Simplified Wet bulb(°F)) - 77 Construction quality Semi-tight Wind speed (mph) 15.0 7.5 Fireplaces 0 • Component Btuh/ft2 Btuh % of load Walls 5.6 6529 25.4 °as Glazing 30.2 4772 18.6 wall Doors 23.5 466 1.8 nfiltration Ceilings 1.3 2271 8.8 Floors 3.4 6125 23.9 Infiltration 2.2 2887 11.2 Ducts 2616 10.2 Piping 0 0 Glazing Floors Humidification 0 0 Ventilation 0 0 Other Ceilings Adjustments 0 Total 25667 100.0 Component Btuh/ft2 Btuh % of load Walls 2.8 3248 14.3 Walls Glazing 48.5 7667 33.8 Internal Gains Doors 18.4 365 1.6 Ceilings 1.7 3140 13.9 Floors 0 0 0 Infiltration 0.5 647 2.9 Ducts Ducts 2982 13.2 Ventilation 0 0 Internal gains 4613 20.4 Glazing Blower 0 0 Infiltration Adjustments 0 Ceilings Total 22660 100.0 Other Latent Cooling Load= 3625 Btuh Overall U-value= 0.104 Btuh/ft2-°F Data entries checked. wrightsoft' 2018-Feb-01 07:06:52 Right-Suite®Universal 2017 17.0.23 RSU05714 Page 1 ..h CBA27UHE AH's11791 sf ADS template 2.5ton.rup Calc=MJ8 Front Door faces: W Project Summary Job: 2791B1 sf ADS 1 •' Date: 11/2018 Entire House By: Dave Bayonet Plumbing Heating and Air Project Information For: Lennar Homes Notes: 40'ADS-2017 Design Information Weather: Tampa International AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 31 OF Outside db 91 OF Inside db 70 OF Inside db 75 OF Design TD 39 OF Design TD 16 OF Daily range L Relative humidity 50 % Moisture difference 55 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 23051 Btuh Structure 19679 Btuh Ducts 2616 Btuh Ducts 2982 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh none (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 25667 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 22660 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 3091 Btuh Ducts 534 Btuh Central vent(0 cfm) 0 Btuh Heating Coolingg (none) Area(ftz) 1817 18W Equipment latent load 3625 Btuh Volume(ft3) 15459 15459 Air changes/hour 0.26 0.14 Equipment Total Load (Sen+Lat) 26286 Btuh Equiv.AVF(cfm) 67 36 Req. total capacity at 0.85 SHR 2.2 ton Heating Equipment Summary Cooling Equipment Summary Make Lennox Make Lennox Trade 14HPX SERIES Trade 14HPX SERIES Model 14HPX-030-230-21 Cond 14HPX-030-230-21 AHRI ref 10258600 Coil CBA27UHE-030-230*++TDR AHRI ref 10258600 Efficiency 8.5 HSPF Efficiency 13.0 EER, 15 SEER Heating input Sensible cooling 25500 Btuh Heating output 26400 Btuh @ 47OF Latent cooling 4500 Btuh Temperature rise 24 OF Total cooling 30000 Btuh Actual air flow 1000 cfm Actual air flow 1000 cfm Air flow factor 0.039 cfm/Btuh Air flow factor 0.044 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.86 Capacity balance point= 31 OF .Backup: n/a n/a Input= 0 kW, Output= 0 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. - wrightsoftm Right-SufteQ�l Universal 201717.0.23 RSU05714 2018-Feb-01 07:06:52 Page 1 ��` ...h CBA27UHE AH's11791 sf ADS template 2.5ton.rup Cale=MJ8 Front Door faces: W Manual S Compliance Report Job: 1791B1 sf ADS Date: 2/1/2018 Entire House By: Dave Bayonet Plumbing Heating and Air Project Information For: Lennar Homes Cooling Equipment Design Conditions Outdoor design DB: 91.3°F Sensible gain: 22660 Btuh Entering coil DB: 75.7°F Outdoor design WB: 77.3°F Latent gain: 3625 Btuh Entering coil WB: 62.8°F Indoor design DB: 75.0°F Total gain: 26286 Btuh Indoor RH: 50% Estimated airflow: 1000 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: SplitASHP Manufacturer: Lennox Model: 14HPX-030-230-21+CBA27UHE-030-230*++TDR Actual airflow: 1000 cfm Sensible capacity: 25500 Btuh 113% of load Latent capacity: 4500 Btuh 124% of load Total capacity: 30000 Btuh 114% of load SHR: 85% Heating Equipment Design Conditions i Outdoor design DB: 30.8°F Heat loss: 25667 Btuh Entering coil DB: 69.6°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Lennox Model: 14HPX-030-230-21+CBA27UHE-030-230"++TDR Actual airflow: 1000 cfm Output capacity: 26000 Btuh 101% of load Capacity balance: 31 OF Supplemental heat required: 0 Btuh Economic balance: -99 OF Backup equipment type: Elec strip Manufacturer: n/a Model: n/a+n/a Actual airflow: 1000 cfm Output capacity: 0 kW 0% of load Temp. rise: 0 OF Meets are all requirements ofACCA Manual S. wri htsoftm 2018-Feb-0107:06:52 9 Right-Suite®Universal 2017 17.0.23 RSU05714 Page 1 ...h CBA27UHE AH's\1791 sf ADS template 2.5ton.rup Calc=MJ8 Front Door faces: W 2018053284 Rcpt:1944465 Rec: 10.00 DS: 0.00 IT: 0.00 04/02/2018 K. A. , Dpty Clerk PAULA S.0'NEIL,Ph.D.P COMPTROLLER CLERK 8 04/02/2018 09:35am 1 of 1 OR BK 97��1 P6 Permit No. Parcel ID No 05-26-21-0080-00600-0110 NOTICE OF COMMENCEMENT State of Florida County of Pasco THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement: 1. Description of Property: Legal SILVERADO RANCH SUBDIVISION PHASES 6,8&9A PB 75 PG 75 BLOCK 06 LOT 11 Street Address: 6582 Wagon Trail Street Zephryhills FL 33541. 2. General Description of Improvement Single Family Residence/Pool/Screen Enclosure/Fence 3. Owner Information: Lennar Homes, LLC. Name 4600 W Cypress St. Ste 200 Tampa FL. 33607 Address City State Interest in Property: Name of Fee Simple Titleholder: N/A (If other than owner) Address City State 4. Contractor: Lennar Homes, LLC Name 4600 W Cypress St, Ste 200 Tampa FL,33607 Address City State Contractor's Telephone No.: 813.574.5700 5. Surety: N/A Name Address City State Amount of Bond: $ Telephone No.: 6. Lender: N/A Name Address City State Lender's Telephone No.: 7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)(7),Florida Statutes: Lennar Homes, LLC Name 4600 W Cypress St, Ste 200 Tampa FL, 33607 Address City State Telephone Number of Designated Person: 813.574.5700 8. In addition to himself,the owner designates N/A of to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statutes. Telephone Number of Person or Entity Designated by Owner: 9. Expiration date of Notice of Commencement is one year from the date of recording unless a different date is specified: WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE-OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. STATE OF FLORIDA COUNTY OF PINELLAS Signature of Owner-or Owner's Authorized Officer/Director/Partner/Manager Vice President Signatory's Title/Office The foregoing instrument was acknowledged before me this 30 day of March ,by Steve Robert Smith as Vice President (type of authority,e. . officer,trustee,.attorney in fact)for Lennar Homes, LLC (name of party ehalf ofwhom i w ent was executed). Personally Known®OR Produced Identification❑-. Nota ignature Type of Identification Produced Name(, ISSe ran Verification pursuant to Section 92.525,Florida Statutes. Under penalties of perjury, I declare that I have read the foregoing and that the facts stated in it are true to the best of my knowledge and belief. S ELISSAM.HOLLERAN Signature of Natural Person Signing Above .: COMMI1SIC) a�FF 985837 s, ` Ex'Ife!June 8,2020 wpdeta/bcs/bcs form: 'i EondodThruTroyFolnImumnoe800495.701p STATE OF FLOWDA,Co UNlY OF PASCO THIS IS T0,CERTIFY THAT THE FOREGOING IS A � • TRUE AND CORRECT'COPY OF THE DOCUMENT ON FILE.,QR',gF,'PUGL,IC Re-coo1�IN THIS OFFICE { �xf' sncst ,� UVITNE S MY HA T S AN "C.MPAL SEAL THIS • DAY OF N't v,r f; PA S.O NSIL,�LM TROLLER .DEPUTY CLERK Lennar Homes-6582 Wagon Trail St-2.276 sq ft o umn Its SQ. FEET PRICE MAIN OR LIVING: 2,276 $ 106.36 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 242,075.36 FEE SHEET $ 1,255.00 ADDRESS $ 40.00 DRIVEWAYJ $ 40.00 BUILDING: $ 1,360.10 ELECTRICAL: $ 282.38 PLUMBING: $ 188.25 MECHANICAL: $ 131.78 SUB-TOTAL $ 1,962.50 TOTAL $ 1,962.50 SEWER: n/a WATER: n/a IRRIGATION: $ - TOTAL: $ - WATER METER: n/a IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 2,515.85 PARK IMPACT FEES $ 769.56 SIF'S: $ 7,128.00 100.0% $ 7,128.00 1.0% $ 71.28 TOTAL: $ 7,199.28 T I F'S : $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 14,116.69 05-26-21-0080-00600-0110 Pasco County Property Appraiser Page 1 of 1 Data Current as Of: Weekly Archive - Saturday, March 24, 2018 Parcel ID 05-26-21-0080-00600-0110 (Card: 001 of 001) Classification 00 - Vacant Residential Mailing Address Property Value LENNAR HOMES LLC Ag Land $0 4600 W CYPRESS ST STE 200 Land $2,413 TAMPA FL 33607-4099 Building $0 Physical Address Extra Features $0 6582 WAGON TRAIL STREET ZEPHYRHILLS, FL 33541 Just Value $2,413 Legal Description (First 4 Lines) Assessed (Non-School Amendment 1) $2,413 SILVERADO RANCH SUBDIVISION PHASES 6, 8 &9A PB 75 PG 075 BLOCK 6 Taxable Value $2,413 LOT 11 Jurisdiction City of Zephyrhills Land Detail (Card: 001 of 001) Line Use Descript o�nZoning Units jType _ Price _�Con--d�ition Value — 1 _ 0100 SFR MPUD 6,000.00 SF $0.40 1.00 ! $2 400 2 0100 SFR MPUD 50.00 SF $0.25 j 1.00 $13 Additional Land Informat_i_on _ Acres Tax Areal .1 30SI FEMA 4 T F I ICode Residential Code I SLVRCPI Building Information - Use 00 - Unimproved (Card: 001 of 001) Unimproved Parcel 00 - Unimproved __ Extra Features (Card: 001 of 001) _ Line Description {Year junits iValue No Extra Features Sales History - See All 6 sales Previous Owner: DUNE FL LAND I SUB LLC Month/Year Book/Page Type _ DOR CodeiCondition Amount _ 03/2018 �9694 / 3124 Warranty Deed _ 05 Vacant Multi-Parcel Sale 2017 9535 05 p _ / / 0546 —_ Certificate of Title 05 I Vacant Multi-Parcel Sale 11/2016 9462 / 0384. Mineral Rights or Royalty Transfers 05 I Vacant (Multi-Parcel Sale http://search.pascopa.com/parcel.aspx?parcel=2126050080006000110 4/2/2018 j PASCO COUNTY, FLORIDA Permit No. R,0z Date Permitted L- Builder Name/Owner Name �h +r �7lJyYla Uf. Control#' ' County Parcel No. -2-t—COPjO- d(m-o ll b SubDiv: 3� C� f F Address/Location &S t5 2- ClassiticationlType of Use 3) j t . ( TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: Z Z7 (- Exempt ❑Yes ❑ No How Determined ft Impact Fee Amount /(o3Z• btu Zone No. TAZ: SCHOOL IMPACT FEE --7 Account (056) Single-Family Detached House Amount $ L f [Z�• :`. (057) Mobile Home ;'. (058) Other Residential 123) Collection Fee Exempt _[ Yes Q No How Determined PARKS AND RECREATION FEE Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation Total Zone TOTAL AMOUNT $ 7�. Exempt ❑ Yes ❑ No How Determined [ : LIBRARY FEE Land Account Land Credit Land Total Facility Account Facility Credit Facility Total Exempt ❑ Yes ❑ No How Determined Total Amoun RESOURCE FEE ERU TOTAL AMOUNT Prepared By Checked By I NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY Acknowledgement below does not Imply acceptance of concurrence,but simply receipt of a copy of this form,placing . l: the building permit owner on notice of this assessment and the conditions of payment for same. DATE RECEIVED BY r RECEIPT NO. DATE BY Single Family Dwelling Plan - - an Review Comments L F.F.E. shall be a minimum-of.8".above the road elevation and an engineered site plan. . 2. -Lots shall be graded_to comply with R401.3 of the F.B.C: . 3.: Coinpaction-test req uired-if 24 or more of fill dirt is lirouglit in:at anyone place: :. 4. :Tie in survey required-before pouring concrete.. 5.. Driveways:require a-R:O.W. use permit:. All-4-sides of driveway thru the sidewalk shall have. expansion matenal..- 6.. All setbacks.shall be met.: 7.- ;All.property:markers shall be_uncovered and marked at time of first.inspection. .8. All A.D.A.-requirements shall be met. . 9.: No:electric;plumbing,mechanical;.or framing shall be covered without an,inspection and approval first. 10.All Garages shall:comply_with:section R302:6 of the.F.B.C.:.(Fire Separation).. I l.Appliances:shall not be installed in:a location where subject to mechanical damage unless protected-by approved barriers. M303.4 of-the F.B.C- 12. Water heaters shall comply with section P607,3 of the-F.R.C. I3..Foundatiori supports for-'A/C units shall-be raised at least 3" above finished grade.. M1308.1. 14. Return air in all.:bedrooms.-F.B.C. M1620.4. 15. Smoke detectors are fo be iristalled:in accordance:with"R313:1 of the F.B.C. 16:All glazing requirements are to be"in accordance with R308.4.of the F.B.C. 17. All means,of egress are to be in:accordance with R311:of the F.B.C. .: .. . 18. `.`Green gypsum.board shall not be used-as.a backer.in.showers:or tubs. R702.4.2.F.B.C. 19.'Combination-type AFCI breakers are,required at all.locations requiring an AFCI type breaker: 20. Carbon monoxide alarms:will be required in-new.construction that uses fossil-burning heating :or appliances or an attached garage:. They shall be installed in accordance'with.the V.B.C. 21. All plumbing, mechanical, and.el'e trical shall:be separate-from unit to.unit: This includes all. . underground:plunibingand electric. 22. All 2011:N:E:C: Codes will be enforced 23. Tamper- Resistant Receptacles in accordance with 406.11 of the 2011 N.E'C .24.:In accordance..with the Land.Development:Code,_lots shall be-sodded before final'at least 10. . feet:around the structure: 25 A copy of the enere.y cacls shall be with permit at all'iinaes 26. Copy of fnal.insulation report shall be.provided with.permit befve.flnaL F:F-E.=Finished Flo or.Elevation Florida Building Code 04 Edition R.O.W.-Right Of Way A.D.A.-Americans with Disabilities Act . N.E.C.-National Electric Code(2011) ! ' � ~ 813-780-00�n City of Zephyrhills Permit Application Fa»8 3-7oo-0O2 Building Department Date Received Phone Contact for Perm ittin g L 813 363 2891 Owner's Name Lermar Homes,LLC Owner Phone Number Owner's Address 1 4600 W.Cypress St.Ste.200,Tampa,FL 33607 Owner Phone Number Fee Simple Titteholde r Name I N/A Owner Phone Number Fee Simple Titleholder Address N/A JOB ADDRESS ' aueovmS|om FSII verado Ranch Subdivision Ph 2,3,&4pAuuEL/u* (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED wswcowrm F7 Aoo/AJT F--� G|aw �--1 [--| DEMOLISH P INSTALL i_l REPAIR PROPOSED USE arn F-� COMM F---� uTnem TYPE oFCONSTRUCTION BLOCK �-1 FRAME [---1 oT�e� DESCRIPTION OF WORK Single Family Residence Pool/Screen Enclosure Fence BUILDING SIZE U/R SP 2276 SQ FOOTAGE HEIGHT 1 Story 08U. I a I I I r"T-1 a a I I . A a a a . a . a a 9 X a a a . . . . . . . ILDING VALUATION OF TOTAL CONSTRUCTION I' 0r7) e�soTw|ux� � � px0o�E��swenoY �-� vvn�o. � �--� � � ' �-� AMP SERVICE ���"� J,' 1pLUM8(No 1 ,_/ uy ��= �'| � ~- MECHANICAL VALUATION �� / i / . / =G/S noDnmo F-1 SPECIALTY [---� oT*ER -- �� �I FINISHED FLOOR ELsV4T0NG FLOOD ZONE AREA U |YBS | �O `_-� ^_� ou|Losm COMPANY Lennar Homes,LLC a|GmxTumE REGISTERED Y/_N_ pssouwncx xddeua 14600 FL 33607 Uuanoo# [TGCsLEonmooAN COMPANY Edmonson Electric, inc. a|GNvnumE REGISTERED Y/ N_ pssuunnsx Address 11034 Skipper Road,Tarnpi i, FL 33613 I License# PLUMBER COMPANY Bayonet Plyrnbing, Heating &AC, Inc SIGNATURE REGISTERED Y/_N_J rssouxnsx LY/N_� xgumoo ucemoo# sEuo*N|CxL COMPANY [Bayonet Plumbing, Heating &AC SIGNATURE REGISTERED _Yl N rscouemsx LY/N_� Address Liconmo# oTasn COMPANY S/gmAruRs REGISTERED Y/ N_ pssounns^ Address Ummon# n u x n m x x x m x x m x x n m n x m m xx m x x u m n x m x x x w x n m m x n m x x u m x n m o n uw x x m o x x m x o u m x x m n RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required unoUa.Construction Plans,omnnwoter Plans vt Silt Fence installed, Sanitary Facilities&1dumpstar;Site Work Permit for subdivisions/large projects COMMERCIAL Attach pV complete sets vf Building Plans plus aLife Safety Page;(1)set uf Energy Forms.n-OvV Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,0nnnvam,Plans w/Silt Fence installed, Sanitary Facilities&I dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach pV sets of Engineered Plans. ^°^PROPERr/SURVEY required for all NEW construction.Directignt Fill out application completely. Owner&Contractor sign back uf application,notarized _ n over$c5no,o Notice ox Commencement|wrequired. (AIo upgrades over$raV0) . ^~ Agent(for the contractor)or Power of Attorney(for the owner)would bo someone with notarized letter from owner auUxorimnqsame / OVER THE COUNTER PERMITTING (copy uf contract required) Remomifshingles Sovmm Service Upgrades A/C Fonceu(PloKGunxey/Fontan:) ~ _ Driveways-Not over Counter Ifuo public modweyu'nendoROW - '- - a 1 NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation understate law. If the owner'or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07; as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner" prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to.meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone W" unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction;I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension:. If work ceases for ninety (90) consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. FLORIDA JURAT(F.S.117.03) OWNER OR AGENT CONTRACTOR Subscribed and sworn to(or affir )Jefore me this Subscribed and sworn to(or affirme before me this OU-pan-1 o by Paul Sweeney30-Ja"•18 by Paul Sweeney Who is/are personally known-to me or as/have pfedused Who is/are personally known to me r as identification. as identification. Notary Public Notary Public Commission No. FF98537 Commission No. FF98537 Elissa M.Holleran Elissa M.Holleran Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped -- �'-= �19SJ4kIt�19l�EVp�W - '' fiklti�,k1�I.CIi�LtN y'C'lmrfitlr�flfli�C�96�4,7 ;,11�2m'�atan�d.N�u��O�' i if>,,pt/a��iJtad;��9C �J!Ik�tIG�dIP-1��;xG{�d , &��dn1�3N'C�yRa�a�vopnt�g6t�G9�111�I i B�Idd'H1N'I�FtI¢I�tyfi4ii13iUI�pll - _ --- TYPE`.D [ANDSCA : .. . co Q AD=112.9 TYPE A� , ✓, � � LOT' 8�. 5.• � . . I 'AD=11.2.4 ` • ' r r FF=112r 0 i w /', W I '� •,. . �' -f'�p�j i ;•• ' it LOT a2 • PAD=W12.1 I I F 46�'2.30 ,' ^C• TYPE A.. ^ 6 • , . ; © `'•TYPE--501 ,� , ti fil F=.112,20 10 LOT $1 +1 I O �A 4i`L ' J 20' !�A(NAGE.'EASEMENT. �o ; Z , PAD=1A 1.5 I i� 11p off. ,�j �. ^o. TYPt A . jl �- FF}=11I�60, � 0 1 OA a-. ' .:L `'10 r r I FF=1.11 50 LOT 30;'' PAD=11 p.8 TYp�oA w% ' 29 1:1 :,.�S€ILDE` ='S:L.OPELO 6 1001 /.PAD=1102 �bTYPE '.FF'.110'.40 o , 'o ' ,b . 'TYPE: B 'gyp ".FF=110.4C� LOT 28 Pj►D=109.7, 0 ° TYPF-A gyp.:. ` 100.70 ` •� N 0 59I PAp=.a 09.0 +. , '� +� TYPE LOT 27 ,�B<�, : ; .� og. :.�. PAD-1 q9:a-'.- �• o� � .�;.: ',` ; .. .. :.�o 0 0 + I -— ---- F=108 4 Off' . LOl of 104:8� 01 a PAD T 07.5 6• -{- FF=109.10 °' �' o TYPE B _ �' ;.;. 6ti F=107.30 , LOT 26 �� .2. 6 � ::�O�o:: LOT 15 PADS-108.4__. o =1106.7.0': . N PAD=106..6' TYPE-B y :s,. �� TYPE B oo ,LOT A.B PAD=106:0 .S 40 •. `'' `,TYPE Boft F=108"90 oa.2 LOT 25 F_ OPAD-1,08.2 m ' o A: � 6a�.. �`- �\ . . �.PID sump 0 +�0 5 108,510 ; , �� ,: 04 94. 1 oa z 0���,`1:. PAD _4`o .8 TR B N kO 10800 �O•p.p Qzo LOT 23 `� 0 ,g1 :I PAD=108.-----XY-P?E �-• w��� 1 �. O %. PAD=106.7 i SKETCH ONLY SEC. 05 TWP. 26 S, RNG. 21 E. PLOT PLAN NOT A BOUNDARY SURVEY BEARING BASIS: LOT 11, BLOCK 6 SILVERADO RANCH SUBDIVISION PHASES 6, 8 & 9A EAST BOUNDARY OF SUBJECT PLAT BEING N 02'35'32" E PASCO COUNTY, FLORIDA. T THIS SURVEY IS SUBJECT TO ANY FACTS THAT 1� MAY BE DISCLOSED BY A FULL AND ACCURATE PRELIMINARY DRAWING: ON LOT AREA CALCULATIONS TITLE SEARCH, ALSO SUBJECT TO SETBACKS, THIS PLAN IS FOR PERMITTING PURPOSES LOT 6050.00 SQ. FT. EASEMENTS AND RESTRICTIONS OF RECORD. ONLY, NOT FOR CONSTRUCTION. VERIFY LIVING AREA = 1838 SQ. FT. ALL DIMENSIONS BEFORE ANY CONSTRUCTION. ENTRY = 32 Q. FT. M UNDERGROUND FOOTER, STEM WALL, AND GARAGE = 406 SQ. FT. II UNDERGROUND UTILITIES ARE NOT LOCATED OR LEGEND: COVERED LANAI =___N_/_A SQ. FT. SHOWN. _�—= PROPOSED DRAINAGE FLOW PATIO DRIVE = 371 SQ. FT. Li J DO NOT SCALE THIS PRINT. DIMENSIONS AND (00.00) = PROPOSED GRADE AC & CONC PAD = 18 _SQ. FT. ¢ NOTES TAKE PREFERENCE. 0 E-00.00 = EXISTING GRADE PRIVATE SIDEWALK = 72 SQ. FT. V) DESCRIPTION NOT CONTAINING PLAT BOOK AND NOTES' IMPERVIOUS =46 % PAGE INDICATES THAT PLAT IS IN = 2760 SQ. FT. PRELIMINARY STAGE AND IS SUBJECT TO LOT GRADING TYPE = 8 PROPOSED PAD ELEVATION 110.3' SOD = 3290_SQ. FT. CHANGE AND/OR REVISION. = FRONT SETBACK = 20' OFF LOT AREA CALCULATIONS CERTAIN DATA SHOWN HEREON BASED ON SIDE SETBACK = 7.5' RIGHT OF WAY = 990.00 SQ, FT. ENGINEERING PLANS PROVIDED BY CLIENT. REAR SETBACK = 15' DRIVE APRON = 233 —SO. FT. PUBLIC SIDEWALK = 275 Q. FT. ` = 10' UTILITY EASEMENT SOD = 482 SQ. FT. TOTALS AREA = 7040.00 SO. FT. DRIVEWAY = 604 -_SQ. FT. SIDEWALK = 347 Q. FT. SOD = 3772 S0. FT. LOT 10 I BLOCK 6 J. I LLJ 0.00'.. �oA ry W o ool �- S 87°24'28" E ,`,2� 110.00' 09 38.17' .� o: • 28.17 O Jr �< LO Q :Ld. . w LL)_j¢ 00 o TRACT A ^ i'r ......... z.5o° a a w -'m ' CN DRAINAGE AREA Z N U 0 : O 2I50' 59'-4" Q N �" z ........ ..........N O - D.DD " �� N. o, N 87°24'28" W \r'. 1 10.00' . o 00 I of I o I LOT 12 04 BLOCK 6 I F J I J m I Q m a Z �_Pc(P) PROPOSED: LOWEST FLOOR ELEVATIONS: S LIVING AREA: 111.00' DESCRIPTION: GARAGE AREA: ELEVATIONS REFERENCED TO LOT 11, BLOCK 6, MAP OR PLAT ENTITLED "SILVERADO RANCH SUBDIVISION PHASES NORTH AMERICAN VERTICAL 6, 8 & 9A", AS RECORDED IN PLAT BOOK 075, PAGES 075 THROUGH 080, OF THE DATUM OF 1988. MEAN SEA PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. LEVEL= 00.00 FT. 0 APPARENT FLOOD HAZARD ZONE: "X" COMMUNITY PANEL NO. 120230 0455 D EFFECTIVE DATE: 09/30/1992 � LEGEND: o (C)= CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, g= CENTERLINE, A/C= AIR CONDITIONER, B/C= BACK OF CURB, C/S= a CONCRETE SLAB, CH= CHORD, CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= COVERED, E/P= EDGE OF PAVEMENT, ESM'T= EASEMENT, /F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE, FIR= FOUND IRON ROD, FN&D= FOUND NAIL & DISK, FPP= FOUND PINCHED PIPE, LFE= LOWEST FLOOR ELEVATION, MAS.= MASONRY, OR= OFFICIAL RECORD BOOK, PB= PLAT BOOK, PCP= PERMANENT CONTROL POINT, PRM= PERMANENT a REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & CAP No. 4493, SN&D= SET-NAt,&-DISK, TBM= TEMPORARY BENCHMARK, U P= UTILITY POLE, W F= WOOD FENCE, R = RADIAL ^_ - JOHN R.BEACH&ASSOCIATES,INC. Drawn By. SMS Square Feet:,' 605Q.00_t'- LENNAR HOMES + SURVEYORS AND MAPPERS Checked By. J 1 911 WEST ST. PETERSBURG DRIVE JRB _ N ONE OLDSMAR, FLORIDA 34677 - WAY (813) 854-1276 FAX (813) 855-8370 Scale: 1"=30' 0 NOT VALID WITHOUT THE SIGNATURE AND Date: PLOT PLAN 1 16 18 ACS /GI7 v THE ORIGINAL RAISED SEAL OF A FLORIDA N R j DATE o LICENSED SURVEYOR AND MAPPER 10 ORIDA R '. LAND SURVEYOR No. 2984 LB#4493 / Revisions: i� 5335 -8TH STREET (813)780-0020 TE of OCCUPANCY CERTIFICA Owner LENNAR HOMES LLC 2 WAGON TRAIL ST 4600 W CYPRESS T Subdiv: S{LVERADO TE 00 Address: 6582 ILLS, FL. TAMPA FL ZEPHYRH{L Work Type: 101-NEW CONSTISFR Parcel: 05-26-21-0080-00600-0110 Sprinklers Construction Type: NOT APPLICABLE Use Classification: NOT APPLICABLE ' Permit Number: 19502 i Date: 6/29/2018 J Issu BY: 1 r BU/LI) WATER MUST BE CHANGED OVER W17TMY0 PAYS GAR'BAGEDEPORT MUST BE APPL ZO pR� aF1 SUANCE oR ToIssu��,�, pppppppp