Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
18-19503
CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020. 1950 BUILDING PERMIT SINGLE.FAMILY RESIDENTIAL - PERMIT INFORMATION LOCATION INFORMATION Permit#:19503 Issued: 4/02/2018 Address: 6608 WAGON TRAIL ST Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 343,131.90 Total Fees: 14,797.91 Subdivision: SILVERADO Amount Paid: 14,797.91 Date Paid: 4/03/2018 Parcel Number: 05-26-21-0080-00600-0080 CONTRACTOR INFORMATION - OWNER INFORMATION Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC Addr: 4600 W. CYPRESS ST STE 200 Address: 4600 W CYPRESS ST STE 200 TAMPA, FL. 33607 TAMPA FL 33607-4099 Phone: (813)574-5743 Lic: Phone: Work Desc: CONSTRUCT SINGLE FAMILY 3,046 SQ FT APPLICATION FEES BUILDING FEE 1,870.20 ELECTRICAL F-E-E 396.00 PLUMBING FEE 264.00 MECHANICAL FEE 184.80 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE-sfr/100% 4,828.00 SCHOOL IMPACT FEE-sfr/1% 48.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32 SCHOOL IMPACT FEE NEW 2,206.68 SCHOOL IMP FEE/MF 2.5% 45.04 s Inspections a uired FO TER 2ND ROUGH PLUMB Misc INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. R NO OCCUPANCY BEFORE C.O. 'CZRfRACTORS SIGNATURE PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIOlf CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER Bank of America,N.A.. - - 1 19 1`'t - LENNAR BiC6WE%LLC.;.- ,u o' CIENT�IAL�iO1�ID _4Ua9NlIAIaERS;e4CC.0UN9`P;.. ,. 4600.WEST CYPRESS STREET;.SUITE 3/28/2018 TAMPA,.FL 33607 - P•AY•TO THE. . _Cit Qf'Ze h fhills: *"1,5ti8:00 ORDER OR Y P Y I zu' One Thousand Five, undyed Sixty=EightOnly" - - -- 'DOLLARS. n LL • - _ - _ - , is MEMO -- — --�— --- = 6820202=15174720100..13U0:4p1201;:; =, AUTHORIZEDIGNATURc.,, il�' -'D':'0:0: oo``.'.�:4:2' °:6�`: 'LENNAR HOMES,LLC. CENTRAL:FLORIDA MANAGERS ACCOUNT 119144 0� LENNAR HOMES,LLC. CENTRAL FLORIDA MANAGERS ACCOUNT 11.914 i 02895856 L.ennar Homes,LLC JPMorgan Chase Bank N.A.' STUB UMCKNU. 9683 , 111I INVOICE 900000.1010.114 1 of I DATE 03/15/18 CO.0 NOURER DATE PAYMEAT,4DYtCE GROSS DISCOUNT NET 15174 15174720037A01435 030618 IS174720.*1401435 ZFEE $9,831.19 S0.00 $9.831.19 rdiJ' , joA 6820202 City orz phy:wlts 7 F13A Tmd &hm 49-8144 3335"I st 54 831.14 $0.00 $4 831.t 4 Zeph'AIMFL33542 ! ...............-------.. .._ _ ..........-._-_.._. • , `JPMor an Chase,Bank N.A. - Unnar.Home LLC:` 9 Tampa I}lylslon- CWr_ago:tL' $ d{�46�33}' `4600 West Cypiess,St;5te',200 io=razz. :r`,;I . Tampa,FL; 7. .. 1 Voirl ijo�er 180 days; 719 3360 f_ = DATE = 0 4 ,J * k, '• P.9-Y 03I15L18:. ,$ ,Q831:•19'": IVIIVB T1i0USAN1)EIGHT HUNDRED THIRTY ONE AND.19/100 1 Gt,'a;.• DOLLARS P. TO THE City ofZephyrhitls AuthoYved sl"tatary: - "opt R. :F'BA Trudy Bihm.49=8144 CIF::::•:4.�5335_Stli Sweet�'• I . Zepfiyr4111s FZ 33342 Authodim sloato, v l --Two Sq{naturcs Rcgwrcd 0n Am6Unu Over S I00 000 0V. f I _ i�; :b, •1 -- - .�,:;tz_''_. to- 11'00 9 68 3 3 911' 1:0719,232261: `886,29333 &Hs r n 1 Whin 0.11d7ng,T.1t,W.1AI... FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Envelope Leakage Test Report Prescriptive and Performance Method Project Name: Gad Builder Name: L ,!FAJ,1_,111AC Allj/W6 S' Street: 46 158 IAl, ,_1511 7X-, & Permit Office: -City, state,Zip: 27'C— 2V, Permit Number: L Design Location: Jurisdiction: Envelope Leakage Test Results Single Point Test Data: HOUSE PRESSURE: FLOW: Leakage Characteristics 1 1 7�7 07 CFM(50): J _1 �ss0Fall ACH(50): R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7',air changes per hour in Climate Zones I•and 2...Testing shall be conducted with a blower door at a pressure of 02 inches w.g. ('50 Pascals). Testing shall be conducted by either individuals asAefined in Section 553.993(5) or (1), Florida Statutes or individuals licensed as sot forth in Section 489.105(3)(f), (g),or(I)or an approved third party.A written report of the results of the test shaill be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other Infiltration control measures; 2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended infiltration'control measures; 3.Interior doors,If installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off-,and 6.Supply and return registers,if installed at the time of the test,shall be fully open I hereby certify that the above envelope leakage Where required by the code official, testing sha 11 bE performance results demonstrate compliance with conducted by an approved third-party: A written report ort o' Florida Energy Code requirements in accordance with the test results shall be signed by the third :park section R402 4 12 471 conducting the test and provided to the code official. SIGNATURE: PRINTED NAME: BUILDING OFFICIAL: DATE: DATE: Testing was conducted in accordance with ANSVRESNETIICC 380 to meet the 2017 residential energy code. t ; Jet Stream° .Ultra Blowing Wool Insulation _NAU Attic and-Cavity Wall Gard o. r.= 9 � n�e`h'1a1Ve Batts and Blankets 'Ejluipmetit-Reguired. gVhen Installed in accordance with the manufacturer's: Il is_recommended that a pneumatic:blowing machine-and a corrugated hose-with a minimum'% internal corrugation,a minimum length recommendations,Knauf Insulation baits-and blankets will of 150%Coils in the hose should n6i'be less than 36',in diameterptabl Accee material feed rate Is 5-35 Ibslm'inute.Recommended teed provide the full R-value, rate is'15-26 Ibslminutec R=Value* Minimum Thickness. 'Thermal 1`6601nancf-(Sidelniall SM.Attic Application)= To obtaln ae- - The slated thermal resistance(R value)lsprovided by installing fn accordance.wtthrhe manufacturer's instructions.Failure to install the Insulation resistance Installed Insulatlon should requtred number of tiagsper 100dsguare 1eeCand exceeiiing the maximum square feet_ coverage per bag'as recommendedby the latiei' ndf 6e less than; will result In lower instalMd R=value§:_161d 6lendin of!fits roducl with other`loose fill insulations is not rec6minended b the manufaclurar.: g F - y A 49 13:76i Cavit y Wall Bag Net Weight-Nominal 32 lbs.,Minimum 31 Its,; R08WD. _ 10:25" R-38 12:00" R'Value* Bags per'1006 SF" Maximum Net Minimum -- --- - " Ta""oblain'.an The numhei'of tiags Coverage per.Bag Weight:per;SF R30HD• 8;25____ . Insulatlon perA,000squarefeet contentso(this Tbe.weight per square , R-30 10,00" CaVit9 resistance of set area`should not ,bag should not feet of:installed ul-- Rr26 9A0 Framing _.Depth_ -_ _oh:___ ._Density-. : ____tie less than _cover more than: shaulA not b"eaess thaai:_ -- -- - - - - - - - _ --" 3 56" R-15 1.S.Ibs lcu,ft,, _16:4 bags 61.0_.•ft: 0;525.16s; R-22 6.50. :2,X4.' 5:50" _ 2"x 6° 5:50" R-23 1.8 lbs lcu,ft,•, 25.8 bags 38:8sq it; `0.8251bs: R-19 B:25""* - _ - - 2"x 8 7:25" R-31. 1.8`I15s)CU,ft 340 bags' 29Asq,ft. 1:0881bs:-:___ R 13 _ 3150' 2"x 10" 9:25" R-39„_ 1.81bs;/c_u,ft... 4$.4"bags;. '23.1 sg.ft: 1281bs,, R-11 3:50 R means resistar a.to heat tldvl,The fgher the R-value,the greater iho insoating power.To get the maTked R•vvue;it is essential that this Insulallogbe Installed properly. 2.50" - R•181ga5.5'oawly,Conforms;loASTA4C665sndPagers! Open,AtlJ ApphcatlpnBagNetWeight-Nominal32lbs.,Minimum"31lbs specilicef!dn HH•1.521F Minimum Bags!_ Maximum Minimum f Initial Settled Fi'aining Adjust(iient 1,660 3F Coverage Vlft'ight Installed Thickness" To compensate for Uam ng.me"mbeis,the number of.tiags'pei The numbei 6f.tiagsl. _Contents of thls The welghusr> Thickness contants.of this 1,000_sq ft..of area to Ue institated should lie'asshown helow. R-Value'- 9 00D,SF of net area hallshould not of Installed:, Installed Insulation bagshould'. Ba s/MSF- Ba SI M$F Toobtalo an insulation should not be less cover insulation should not should be'less: -not'--1 more 9 9 resistance,(R-ValueJ of:- th-a: more than: b_o-less them _ than: then: Joist 16"O.C; -24"•,O.C. R=60 29 7 33.6'SF 9521bs; 1,9,750" 19.750" R=Value Dimensions. F.ramfrig Framing - - 2x4. _ 29.2; _ 29.4_ __ R=49 23:5 42,5 SF" ',753 lbs, 16:37b"__ - 16:375 R=60 2x6 28:9 =29.1 R-44 20.9 47:8$F _ .670lbs. _ 14,875°. 14'V5" .2x8_-_ _28.6: 28;9' - R 38- - 17 8 56;2$F - ;569.Ibs;- 13.000" 13.000"' - _ 2x4 }23,0 23:2. R=30 13.6 73.3:SF .437-Ibs. -_--. - 1:0:375"- 10,375° - _ _ . R-49 2x6 22,7 22.9. - = _ R 26 ___ ______11.8__ -___�85.0_$F______._3771bs: 9.125" 9:125" 2x8-- _....__.224._ - - 22.7--- - -- -- -- -2x4 20:4 ;20:6' R-22 9:8 102:2:SF 3131bs. T-750" 7.750" R=44 2x6 20.1 -2- R=19 8:4. 119;3.$F.__ ,2661bs.- ;635,0° 6.750"_ -2x8' 19.8'_. '20,1_ R-13' 57 175:3 SF .183 Vs. 4:750" 4:750" 2x4. 17.3 1.7.4" ft 11 AT 216ASF .152I15s. 4.000" 4,000" R-38 2x6_- _. _'17:0 17.2' -_ •. . eThsR�arypRErde;dwaunU4s,rceafn-28 16.7 17.0- esb�ta+anC ncse'.bfnoadlh 3:zbapifM ePsv(.0N"e.nuTa hMa BtugtEh3qMeti,,vN1'p�me:Renvtsa�ute6.5tlTgf5AreCoTi eidr,ltTeyp5ast'mu;4dmg pe velhd adaAoF 13:2 r:T13.3 gaedaer rwa'ttlSr;iF3d kgass eonpHenHlm•I].7,D2300 pBs,-Tayti'rcrxtsuGau seseBM,R 1v5iO4 e- o-Ps3a'reYdd>emteam9iynte�dming'a'�ccudM lwa!sw?e. w�I,C,881,ai!dC5fa! gel thema!edRva ue lt�;essent al Ma;tha insJon 6evstdpbpc y:it you eattyaaeell,gelrsn Will 2x6 12.9 13:1 - a�dt� tnemcarety;i�swuaasao rote.anll�sPaaage _ "Bedon find Part'2 Ses seLNiy stedj,Ne�edkted sc-Ci�nentorva 20-yepGricdvw;d Ee t paceN a.l°55:'Ipis a:uo-etl btsepGng a OiermF.�Y lnsgn3tapL Thereb}e,tl!e ltsief'ei sM ssiEed 24- _ '12.6.`-----.-12.9---_ D k nessea"s a Eftecta eiy he same. 2x4 111. -.11 A VoSFjfa ii is a iegistil d tralanmr AiW, 11-26 2ka 11.0. 11.2 Builder's Insulation Statefnent 2x8 `10.8 11.0 Jet Stream;VItra_`has tie_enn istalled it conformance with:the_induded:recommendations to provide a tlie_rinal resistance of.; 2x4 9.3 9,5' k4zilue Thickness R42 2x6 11..._ 93' 1 Attic Area _ R=_ _ at. Inches,. &a 8.8 91 Sloped Ceilings R= at inches- 2x4. _ --7,9 8.1 Walls; R= - at - Inches I R=19 2x6 7:7 7:9; - --- - 2x8 _7.7 _.... _7,7" Floors,(over-an un heated trawl,space) R- at: )nches j 20 6.3 5;4 - Crawl:Space Per'imetec R- at° Inches R-13 2x6 5.0 5:2 Datelnstalleif, 2x8 - 4.8 fiff Blown Insulation has been Installed'in coriformance;with.the above recommendation_s to provide an"R-value,of 2x4` 4.3 Ti_ R R''1 usin ba s of this nsitlation to cover ` 'g�( _ � - square feet gf area•. RAO 24 - 47A 4.3- at a niinimum.thickness of 18,? inches: 2ii8 3.8 4,1 _ uC Enviranin"M. - Iri tt�i 6REENGUARD G"Id'" -.I•„ •r �= - --__- _ �N / -- _ Compan e 'U.Fmlren"v,!GRFENGVARD CWYd nd it -y - lri Em9renmrrJ rolldmod ro ho lams&leAyde Gco ' inM ir""m""iGREENGUARD( Home Bul<det(sig!iature) •. 'C"itif"urb�proerom'•-', . HwWdr w"c"rGl,id GREENGUa!tD rt*dmdr krlop chOi"Icul Compzny __ -"Date.- omf"lonif b;l"dow )«mop"Inrww"eo", - The covdirage information on thisAtticlSidewall eard"appiies to the.etitke.United States(including Minnesota). _wyuuu.knautinsulation.us. ! Knauf;Insulation,Inc:.On6 KhaUf Drive,Sfielliyyille,IN 46176 Tel:(800)825-0434 ezt:8300`FAX:.(317)398 3675- PASCO COUNTY, FLORIDA Permit No, S3 / Date Permitted 2� Budder Name/Owner Name 1 n o_r�.9-f' t' Z Le. Control County ParcehNo. a a-�r-21 (�(i�0-DZ?�oO�D�b SubDIV: �r�.l�err t�� Address/Location {p o-.6 (}mac-c v. -tkA t____ ClassiPicationlType of Us$ yv 1,,- 4""v I� '! TRANSPORTATION IMPACT FEE Rate: Sq.FtUnit: �•�? Exempt []Yes ❑No How'Determined Impact Fee Amount $ �3,� 32-•GYD Zone No. TAZ. SCHOOL IMPACT FEE Account (056) Single-Family Detached House Amount $ 7� f • 0 t� S (057) Mobile.Home (058) Other Residential 23) Collection Fee Exempt d Yes ❑No How Determined PARKS AND RECREATION FEE Land Account Land Credit Land Total Recreation Account Recreation Credit -Recreation Total Zone TOTAL AMOUNT $ Exempt []Yes 0 No How Determined LIBRARY FEE Land Account Land Credit Land Total Facility Account Facility Credit Facility Total Exempt ❑Yes '[] No How Determined Total Amount Cam_ RESOURCE FEE ERU _ TOTALAMOUNT Prepared By -- Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFiCE-OF PASCO COUNTY Acknowledgement below does not imply acceptance of concurrence;but simply reoelpt of•a copy of this farm,placing . the building permit owner on notice of this assessment and the conditions of payment for some. DATE RECEIVED BY RECEIPT NO. DATE BY NN�N00AUU�0NNNNNNN |NU�NNNUNNNN|UUUNNNN 201805328' ` ----'------------------ — — — 00 Rmpt:1944465 � ' Rec�: 10 00' D8: 0'00 ` ' � t� Clerk 04/02/2018 N' p. ^ �r__ __ —'-- o u'ws��.p��o pusuo »�Rn u cunprno���^ . pnvm � 1 Of `- 04'02'20 OR BK � �� ��_��������°W pG mwn / Permit No. Parcel / NOTICE OF COMMENCEMENT state of Florida County of Pasco THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 71o. Florida Statutes, the following information iu provided m this Notice nrCommencement: 1. Description ofProperty: Legal SILVERADO RANCH SUBDIVISION PHASES 6,8&9A PB 76 PG 75 BLOCK 06 LOT 08 6608 Wagon Trail Street Zephryhills �L 3�541 Street Address: en Pool/8 Enclosure/ o. oonem|oommipxvnnf|mpmvnmom Single Family Reoid ResidenceScreen Fence n. Owner Information: LonnorHnmem LLC Name 4600 W Cypress St, Ste 200 Tampa FL�}36O7 Address city sxom Interest inpmv*rty� Name m Fee Simple Titleholder: N/A (if other than owner) Address city State 4. Contractor: Lennar Homes, LLCName 4600 W Cypress St, Ste 200 Tampa-- FL ,33GO7' Address city State Contractor's Telephone No.: 813.674.5700 5. surety: mumn Address city State Amount mBond: Telephone No.: 6. Lender: Name Address City State � Lender's Telephone Nn.: r by the owner upon whom notices or other documento'may be served as provided by � noomonr1a13(l)h$(7).rw6duatamteu:Name . 4600 W Cypress St, Ste 200 Tampa FL,, 33607� Address city State Telephone Number uf Designated Person: 813.574.5700 o. m addition tohimself,the owner designates v[____ to receive a copy of the Lienor's Notice as provided in Section 713.13(l)(b),Florida Statutes. Telephone Number vy Person n,Entity Designated uvOwner: n. Expiration date of Notice of Commencement is one year from the date of recording unless-a different date iospecified: WARNING TOOWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATIONOF THE NOTICE O COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS CHAPTER ns8Ucr IN YOUR P/n1wo TWICE FOR !mPnOvsMswrs To YOUR PROPERTY. NOTICE M U BE RECORDED AND POSTED DN THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. STATE opFLORIDA COUNTY orP|NELLAS ^womumm Owner ur Owner's Authorized mnmanu,mm^nrmnnvnmanaAr, Vice PresidentSignatM's Title/Office The foregoing instrument was ocxnnwleuoou oemm me this 30_day m March —by Steve Robert Smith as Vice President (tVDe of aiAhmllS�_e�_g_,o er,trustee,attorney in fact)for Lennar Homes, LLC -�--(name of part on bebalt"bDNhorn instrument was executed). Personally Known a-QR Pro uyva�/uv���oo�n[]� / ' ' \_ � Type cxmonn�atmmpmuuveu man,��mV /�//ss`� nu//e/a// Verification Floridao|h of perjury,I declare.tbaLl have read the foregoing and that the facts stated in' it are true,to the best of my knowledge and belief. . Signature mm wanu Pe rson ' ' ��� eATE OF FLORbA,COUNTY OF PASCO THIS IS AND CORRECT COPY OF HEEDOCUM DOCUMENT TRUE ° ON,FLLE OR OF PUBLIC RECORD IN THIS OFFICE a In hod We Trust ® WITNESS MY HAND AND OFFICIAL SEAL TC IS a° �..__DAY OF - 18,7 PAULA S.O'NEIL,CLEva R &COMPTROLLER By DEPUTY CLERK OF `= P'ASCO COUNTY, FLORIDA Permit No. IJ3 Date Permitted -Z- Builder Name/Owner Name �o rn.v+e::c � S Z �°, Control#' . County Parcel No. ()a'-2(o- 1-6C6o.00(xoo 608a SubDIV: Address/Location 06 U tL Classification/Type of Use Si L2 ,G TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: d Exempt ❑Yes ❑ No How Determined Impact Fee Amount 00 Zone No. TAZ: SCHOOL IMPACT FEE Account (056) Single-Famlly Detached House Amount $ Z� 1 2-6 • U b (057) Mobile Home (058) Other Residential 123) Collection Fee Exempt []Yes ❑No How Determined PARKS AND RECREATION FEE Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation Total Zone TOTAL AMOUNT $ Zby_�rj"(� Exempt ❑Yes ❑ No How Determined LIBRARY FEE Land Account Land Credit Land Total Facility Account Facility Credit Facility Total Exempt ❑Yes ❑ No How Determined Total Amount RESOURCE FEE ERU TOTAL AMOUNT Prepared By Checked By j NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY Acknowledgement below does not Imply acceptance of concurrence.but simply receipt of a copy of this form,placing the building permit owner on notice of this assessment and the conditions of payment for same. DATE RECEIVED BY RECEIPT NO. DATE BY ` 03-780-0020 City OfZeohvrhi\ls Permit Application Fax-83-780-0021 Building Department � Date Received uxonuonx xuoxxouu " . " " " . . Owner's Name o�mphone Number Owners Address 4600 ress FL 33607 Owner Phone Number Fee Simple Titleholder Name I Owner Phone Number Fee Simple Titleholder Address NIA JOB ADDRESS P08 Wagon Trail Street LOT# 10080 mUgo|mS|ow Sliverado Ranch Subdivision Ph 2,3,&4PAnoEL/o#105-26-21-0080-00600-0080 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED wcwcomsm ADD6ALT [---1 S|GN �—� F—� DEMOLISH P INSTALL [_] REPAIR PROPOSED USE 0SFn F—� COMM [---1 oT*ER TYPE oFCONSTRUCTION U�r��^ auoox F-� F�xw� �--� sns�� F—1 v ^_--� DESCRIPTION oFWORK Single Family Residence Pool/Screen Enclosure/Fence BUILDING SIZE :1So FOOTAGE L����___� ns|mHT 12 Story BUILDING P��S_ VALUATION OF TOTAL CONSTRUCTION E�eoTn|c�� �� P�non�ou�ws��Y [--1 vvn�o. �—� � � ' �—� AMP SERVICE �_l ` OPLUM8|NG A MECHANICAL vALUATION0F MECHANICAL INSTALLATION =GA8 ROOFING [—1 SPECIALTY [---1 OTHER FINISHED FLOOR ELEVATIONS �� Do FLOOD DYES O V � | � �� �� au|Losm COMPANY Lennar Homes,LLC mGm/TuRe REGISTERED Y/_N_ rcsouRns^ L�a�_� Address FL 33607 uoenuo# ELECTRICIAN COMPANY Edmonson Electric, Inc. o|Gm/nmRs REGISTERED _Y/ N_] pssouxms^ L_L 1�_] xuumno 11034 Skipper Road,Tarnra, FL 33613 License# PLUMBER o|GmxTuos REGISTERED Y/_m_] pssounnsN I Y/1N] xuumso uca^oo# MEcuxm|cAL COMPANY t Plumbing,Heating &AC, Inc SIGNATURE REGISTERED _1/_m ] pssouunsx xuumas Ummoe# OTHER COMPANY omm/TuRE J REGISTERED [ Y�LN_J FEsoumRe^ LLLN_j Address 14211 Shoal Line Blvd, Spring Hill, FL 34607 Licemm# xmxowxxxmxxxmxx � uxumxxmxxxoxxxuxxmxxxmxxwxxxwxnwxxx � xxmxoomxxxmxxxn RESIDENTIAL Attach(2)Plot Plans;;4 sets of Building plano;(1)set mr Energy Forms;n-OvW Permit for new construction, Minimum ten(i0)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Sift Fence installed, Sanitary Facilities&1 dumpmer;a|te Work Permit for subdivisions/large projects ^ COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(1O)working days ofter.oubmiva!date. Required nno80.Construction Plans,stonnmmter Plans w/Silt Fence installed, Sanitary Facilities&I clumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach pV sets of Engineered Plans. ****pROpsRTY SURVEY required for all NEW construction. Fill out application completely. Owner m Contractor sign back ofapp|iuobnn.notarized If over$000O'u Notice m Commencement|srequired. (uC upgrades over$rsOn) °~ Agent(for the contractor)or Power of Attorney(for the owner)would be someone With notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy o«contract required) Rmmofs!fshingles Sewers Service Upgrades 8/C Fennon(P|oVeunxey/Footu8e) Driveways-Not over Counter ifon public madwayv'neeuvROW ` NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed" restrictions". which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS' AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recover�,Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must.be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner" prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of-a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone W" unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE 4 COMMENCEMENT. FLORIDA JURAT(F.S.117.03) OWNER OR AGENT X CONTRACTOR Subscribed and sworn to(or affirrri d)before me this Subscribed and sworn to(or affir ed)before me this JU-Jan-10 by Paul Sweeney30Jan•18 by Paul Swee Who is/are personally known to me o hasihave prGd61G Who is/are erson illy known t me or tification. as identification. o a ublic Notary Public Commission No. FF98537 Commission No. FF98537 Elissa M.Holleran Elissa M.Holleran Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped .� ' -: 6�r��7 ���'1�filiru'dngd�tlo6aB@,T . 6��d1IYN'(YmyPaldIO9Itu4Iloo & dnIIY�J'I�syNokua01-40 wLamnII� Lennar Homes-6608 Wagon Trail St-3,046 sq ft -NEW FEES Column ts SO. FEET PRICE MAIN OR LIVING: $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: VALUATION $ - FEE SHEET ADDRESS DRIVEWAY BUILDING: $ - ELECTRICAL: $ - PLUMBING: $ - MECHANICAL: $ - SUB-TOTAL $ - TOTAL i SEWER: n/a WATER: n/a IRRIGATION: $ - TOTAL: $ - WATER METER: n/a IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE FIRE 5% $ - TOTAL: SUB-TOTAL $ - PARK IMPACT FEES SIF'S: $ 2,251.72 100.0% $ 2,206.68 1.0% $ 45.04 TOTAL: $ 2,251.72 balance owe TIF'S: 99% $ - 1% $ - TOTAL: $ 2,251.72 '+• ; PE�`�D�'•LANDSCAI ''TYPE10- J .. I PAp=1.1'3.2 . Qj s , ' 1 . _ 'TYPE FF=1"13.60 ,�r ?� ;•:. �o h: ' :W� LOT 3•. PAD=112.9 �.,,• ;D TYPE A II >::� -. , :� h.; :�'►,Y.SE • ,1'IVi I I HQ.".'1.1.2.4 PE EP' 1 F 1 O I � , ' • , W I /• ...( •,1f LOT �� ' .. PAD;1'12.1 I i ?'2.30 N: TYPE A. � -� 9 I ( T 9. `;fig f' 1d6 ; • •''�' �. o © TYPE F=FI12,20 I 1.0 LOT 31 �-� t p �A - q;`l- J 20• R'AINAGE.'EASEMt_NT . PAD=1A 1.5 I 1 I p = ;.. o. TYPi_ A . �I '� I �� ; '.FF'-11 60,' TOA t NO , p .' � %,. ..:.,{vt�pE 1•Big ;' .: i' p . . '' .. 0���. �,. FF=111 50 .LO PAD T 30;' =11Q:8' ► I �;�' :'e.; o^ TYP6,oA �o '�I ` I; :Ftl1:1J.00 '`° ► �-'`,' It NQ eo AND,DIG:. V-8WA'' LFF=10.90 :1.: SIDE 'SLOPE9 6LOT PAD=110,2 •, : INfV.;��L.`. TYPE A-- ,gyp° ti� �O� !#1`116.40 I `s �- +1o�RA4=109.7 : i TYYPE': B LOT 28 PD=109.7-' o ,. oar• , i-1 FF=109.80 . 4�c 5 ; PA0=4 69.0 ♦♦ ,... . .. ...: :. LOT 27 ' f'. YPE� ♦ g. , ' r ♦ i.�0 O PAD=1 o� I p'I; pAO�,07.5 "-` ` + � � � TYPE B '10. FF=109.10 ' LOT 26 LOT 15 % PADS-108.4__+ „t`�.. , ' o =-106.7.0': : ,�•. TYPE B '-� ' PAD=106..6' ?,� TYPE B �o• LOT °1.•6 ro) h PAD=106:0 g TYPE B.' ' - p6. tk� p ;►:: 'far ',. pw' oe.' LOT •25 �,1=� F 108 AD= 108.5 PK t1 b �• ...:,, 0 -gyp ' ` z{i' o r h• `� dAP 0 LQT - . 0 �.. PAD—d`17.8 rc ` G ` 108.00: q:. � � + 5. j. �1a•❑ a4 Q�0 LOT 23' a° PAD-107: 105 OD - -----.TYPE,,B �- w�°' bN `�� .•� 00 0 �F=1ga`4so00, 11 ��' �, :gip �':• �;'. 0...'ti•.\ 'PAD_106.7 10.. ':','HYPE_ B 10 Single. Family Dwelling Plan Review.ComrrientS 1: F.F.E. shall be.a minimum:of.8".above.the road elevation-and an engineered.site plan. ;: 2. Lots shall be-graded to.comply with R401.3 of theF.B.C: 3. :Compaction test required if 24" or more of fill dirt is brought-in:at any one place: .4:. :Tie in surveyrequiredbefore pouring concrete. 5.. Driveways:require a R.O.W. use permit.' AII.4:sides of driveway thru the sidewalk sliall_liave. expansion material:. . . .. . 6.. All setbacks.shall be met:.- 7._ All property markers shall be uni covered and marked at time'of first inspection: 8: :All A.D.A.requirements shall'be met. . 9.. No:electric.plumbing,mechanical. or framing shall be covered without an inspection and approval first. . . 10. All. Garages shall,comply.-with-section R302.6,of.the.F.B.C::(Fire Separation). 11:Appliances shall iiot be installed in a location'where subiectto mechanical damage unless .protected by approved barriers: M303.4'of.the F.B.0 12. Water heaters shall comply with section.P607.3 'of the F.B:C. 13. Foundation supports Tor A/C units steal"1 be raised at least 3" above nished grade.. M1308.1. 14. Return air in all b.edrooms..F.B.C. 1VL1620.4 15: Smoke detectors'are.to be installed:in accordance.withi R313:1 of the F.B.C. 16.All glazing requirements are:16 be in accordance with R308.4.of the F.B.C. 17. All means of egress are to be in accordance with R311.:of the F;B.C.- 18. "Green gypsum.board"shall not be used-as.a backer in showers or tubs. R702.4:2,F.B.C. 19. Combination-f ype AFCI breakers are.required:at all locations requiring an AFCI type breaker: . . :. . - 20: Carbon monoxide,alarms will.be re uired in'riew constr 'etionthat uses fossil-burnin heating .. q . - . g:. g or appliances or an attached garage:, They shall be installed in accordance'with the F.B.C. 21. All plumbing,mechanical, and electrical shall:be separate from unit to unit: This includes all = underground plumbing and electric: 22.. All pO11:N:E:C: CO*des p ill be enforced:.' .23. Tam er-' Resistant Rece tacles in accordance with 406.11 of the 2011 N:E:C .24::Iri accordance:.with the Land:Development Code. lots shall be,sodded before final at least 10 feetaround the structure 2S.A.copy of the energy cacls shall be with permit at all times. 26 Copy of final insulatioiz report shall be.provided with.permit-before.finaL F.F.E:-Finished Floor,Elevation F.B:C=Florida Building Code 6 'Edition: R.O.W.-Right'of Way A.D.A.-'Americans with.-Disabilities Act N.E.C:-National.Electric.Code(2011): - Lennar Homes-6608 Wagon Trail St-3,046 sq ft o umn Its SQ. FEET PRICE MAIN OR LIVING: 3,046 $ 112.65 OTHER AREA UNDER ROOF: _ $ 88.00 OTHER: - $ - VALUATION $ 343,131.90 FEE SHEET $ 1,760.00 ADDRESS $ 30.00 DRIVEWAY $ 45.00 BUILDING: $ 1,870.20 ELECTRICAL: $ 396.00 PLUMBING: $ 264.00 MECHANICAL: $ 184.80 SUB-TOTAL $ 2,715.00 TOTAL $ 2,715.00 SEWER: n/a WATER: n/a IRRIGATION: $ - TOTAL: $ - WATER METER: n/a IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 3,268.35 i PARK IMPACT FEES $ 769.56 SIF'S: $ 4,828.00 100.0% $ 4,828.00 1.0% $ 48.28 TOTAL: $ 4,876.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 12,546.19 Lennar Homes-6608 Wagon Trail St 3,046 Sq ft Column ts SO. FEET PRICE MAIN OR LIVING: 3,046 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 343,131.90 FEE SHEET $ 1,760.00 ADDRESS $ 40.00 DRIVEWAY $ 40.00 BUILDING: $ 1,875.20 ELECTRICAL: $ 396.00 PLUMBING: $ 264.00 MECHANICAL: $ 184.80 SUB-TOTAL $ 2,720.00 I TOTAL $ 2,720.00 SEWER: n/a WATER: n/a IRRIGATION: $ - TOTAL: $ - WATER METER: n/a IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 I SUB-TOTAL $ 3,273.35 PARK IMPACT FEES $ 769.56 SIF'S: $ 7,128.00 100.0% $ 7,128.00 1.0% $ 71.28 TOTAL: $ 7,199.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 14,874.19 05-26-21-0080-00600-0080 Pasco County Property Appraiser Page 1 of 1 Data Current as Of: Weekly Archive - Saturday, March 24, 2018 Parcel ID 05-26-21-0080-00600-0080 (Card: 001 of 001) Classification 00 - Vacant Residential Mailing Address Property Value LENNAR HOMES LLC Ag Land $0 4600 W CYPRESS ST STE 200 Land $2,413 TAMPA FL 33607-4099 Building $0 Physical Address Extra Features $0 6608 WAGON TRAIL STREET ZEPHYRHILLS, FL 33541 Just Value $2,413 Legal Description (First 4 Lines) Assessed (Non-School Amendment 1) $2,413 SILVERADO RANCH SUBDIVISION PHASES 6, 8 &9A PB 75 PG 075 BLOCK 6 Taxable Value $2,413 LOT 8 Jurisdiction City of Zephyrhills Land Detail (Card: 001 of 001) Line _ Use ric Descriptio_Zoni ___T ng _ Units ype Price_ TCondition 11Value 1 0100 SFR _ MPUD 6,000.00 SF_ j $0.40 1.00 - -$2�400� — 2 0100SFR MPUD 50.00 I SF - $0.25 1.00 j $13 Additional Land Information FEMA Acres I ia 30SI Code -- I Residential Code SLVRCPI 0:14 Tax Are Building Information - Use 00 - Unimproved (Card: 001 of 001) Unimproved Parcel 00 - Unimproved Extra Features (Card: 001 of 001) Line_- _ Description - �IYear �jnits No Extra Features Sales History - See All 6 sales Previous Owner: DUNE FL LAND I SUB LLC Month/Year;Book-V e - Type - �DOR Code ConditionTAmount 03/2018 9694 / 3124_ _Warranty Deed_ A 05 Vacant Multi-Parcel Sale -_ 05/2017 9535 / 0546 _ _T Certificate of Title 05 Vacant Multi-Parcel Sale 11/2016-2462 / 0384 Mineral Rights or Royalty Transfer 05 Vacant Multi-Parcel Sale i http://search.pascopa.com/parcel.aspx?parcel=2126050080006000080 4/2/2018 SKETCH ONLY SEC. 05 TWP. 26 S, RNG. 21 E. PLOT PLAN NOT A BOUNDARY SURVEY BEARING BASIS: LOT 8, BLOCK 6 EAST BOUNDARY OF SUBJECT PLAT BEING N 02'35'32" E SILVERADO RANCH SUBDIVISION PHASES 6, 8 & 9A PASCO COUNTY, FLORIDA. THIS SURVEY IS SUBJECT TO ANY FACTS THAT MAY BE DISCLOSED BY A FULL AND ACCURATE PRELIMINARY DRAWING: ON LOT AREA CALCULATIONS TITLE SEARCH, ALSO SUBJECT TO SETBACKS, THIS PLAN IS FOR PERMITTING PURPOSES LOT = 6050.00 Q. FT. EASEMENTS AND RESTRICTIONS OF RECORD. ONLY, NOT FOR CONSTRUCTION. VERIFY LIVING AREA = 1093 SQ. FT. ALL DIMENSIONS BEFORE ANY CONSTRUCTION. ENTRY = 35 SQ. FT. UNDERGROUND FOOTER, STEM WALL, AND GARAGE = 427 SQ. FT. p UNDERGROUND UTILITIES ARE NOT LOCATED OR SHOWN. LEGEND: COVERED LANAI =--N/A SQ. FT. �—►= PROPOSED DRAINAGE FLOW PATIO - 23 SQ. FT. DO NOT SCALE THIS PRINT. DIMENSIONS AND (00.00) = PROPOSED GRADE CONC. DRIVE = 408 SQ. FT. < ? NOTES TAKE PREFERENCE. E-00.00 = EXISTING GRADE A/C & GONG PAD = 8 SQ• FT. PRIVATE SIDEWALK = 31 SQ. FT. U) DESCRIPTION NOT CONTAINING PLAT BOOK AND IMPERVIOUS = 34 % PAGE INDICATES THAT PLAT IS IN NOTES: = 2035 Q. FT. PRELIMINARY STAGE AND IS SUBJECT TO LOT GRADING TYPE = B SOD = 4015 SQ. FT. CHANGE AND/OR REVISION. PROPOSED PAD ELEVATION = 112.4' FRONT SETBACK = 20' OFF LOT AREA CALCULATIONS CERTAIN DATA SHOWN HEREON BASED ON SIDE SETBACK = 7.5' RIGHT OF WAY = 990.00 SQ. FT. ENGINEERING PLANS PROVIDED BY CLIENT. REAR SETBACK = 15' DRIVE APRON = 233 SQ. FT. s = 10' UTILITY EASEMENT PUBLIC SIDEWALK = 275 SQ. FT. SOD = 482 SQ. FT. TOTALS AREA = 7040.00 SQ. FT. DRIVEWAY = 641 Q. FT. SIDEWALK = 306 _SQ. FT. SOD = 4497 Q. FT. LOT 7 •.I BLOCK 6 W O.OD' � 1 W _ �- S 87°24'28" E ,L°� 110]46.50' o ........1.....: ..p 25.50 O 43'-b" pJ I �4 ........�..... H ¢ InQ a: W * 0150' Wr�C-2 'o 20.50' v7 N N cV ... a w' '" a�a ov - TRACT A o-a w a m aNDRNNAGE AREA a !�.50' .....3 < o.00' .1N 87°24.28" W Ins.0" �� 110. r� (L �o r�i .•�.I J s�J M I 0 N LOT 9 o I BLOCK 6 I M U J Ca • J Q T 0 1 I 10 �_PC(P) PROPOSED: Z LOWEST FLOOR ELEVATIONS: o LIVING AREA: 113.10' DESCRIPTION: GARAGE AREA: ELEVATIONS REFERENCED TO LOT 8, BLOCK 6, MAP OR PLAT ENTITLED "SILVERADO RANCH SUBDIVISION PHASES NORTH AMERICAN VERTICAL m 6, 8 & 9A", AS RECORDED IN PLAT BOOK 075, PAGES 075 THROUGH 080, OF THE DATUM OF 1988. MEAN SEA a PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. LEVEL= 00.00 FT. O "' APPARENT FLOOD HAZARD ZONE: "X" COMMUNITY PANEL NO. 120230 0455 D EFFECTIVE DATE: 09/30/1992 `o LEGEND: o (C)= CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, g= CENTERLINE, A/C= AIR CONDITIONER, B/C= BACK OF CURB, C/S= a CONCRETE SLAB, CH= CHORD, CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, GOV.= COVERED, E/P= EDGE OF PAVEMENT, ESWT= EASEMENT, /F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE, FIR= FOUND IRON ROD, FN&D= FOUND NAIL & DISK, FPP= FOUND PINCHED PIPE, LFE= LOWEST FLOOR ELEVATION, MAS.= MASONRY, OR= OFFICIAL RECORD BOOK, PB= PLAT BOOK, PCP= PERMANENT.CONTROL POINT, PRM= PERMANENT a REFERENCE.MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & CAP No. 4493, SN&D= SET NAIL & DISK,• TBM= TEMPORARY BENCHMARK, U P= UTILITY POLE, W F= WOOD FENCE, R = RADIAL _ - a JOHN R.BEACH&ASSOCIATES,INC. Drawn By. SMS Square Feet: 6050.00 t_ i ENNAR HOMES cl� SURVEYORS AND MAPPERS > Checked By. 911 WEST ST. PETERSBURG DRIVE JRB In ONE OLDSMAR, FLORIDA 34677 i WAY (813) 854-1276 FAX (813) 855-8370 Scale: 1"=30' o - Ito I NOT VALID WITHOUT THE SIGNATURE AND Date: PLOT PLAN 1 16 18 ACS -a THE ORIGINAL RAISED SEAL OF A FLORIDA JOH EACH ATE-� LICENSED SURVEYOR AND MAPPER FjoMIDA REP. LAND SURVEYOR No. 2984 B#4493 / Revisions: i� FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 2575A1 sf ADS 2017 Builder Name: Lennar Homes Street: 6608 Wagon Trail Street Permit Office: City of Zephyrhills City,State,Zip: Zephyrhills,FL, Permit Number: .l `Z 5a3 Owner. Lennar Homes Jurisdiction: 611600 Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(2613.1 sgft.) Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1264.00 ft2 b.Concrete Block-Int Insul,Exterior R=4.1 996.67 ft2 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 352.44 ft2 4. Number of Bedrooms 4 d.N/A R= ft2 5. .Is this a worst case? Yes 10.Ceiling Types (1491.0 sgft.) Insulation Area a.Under Attic(Vented) R=30.0 1491.00 ft2 6. Conditioned floor area above grade(ft2) 2584 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ftZ 7. Windows(175.6 sgft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 218.6 a. U-Factor: Dbl,U=0.54 71.25 ft2 b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 298.2 SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.56 71.00 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.28 a.Central Unit 18.0 SEER:16.00 b.Central Unit 25.2 SEER:16.00 c. U-Factor: Dbl,U=0.56 33.33 ft2 SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency d. U-Factor. N/A ft2 a.Electric Heat Pump 17.5 HSPF:8.50 SHGC: b.Electric Heat Pump 21.8 HSPF:8.50 Area Weighted Average Overhang Depth: 1.190 ft. Area Weighted Average SHGC: 0.300 14.Hot water systems 8. Floor Types (2584.0 sqft.) Insulation Area a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 1093.00 ft2 b. Conservation features EF:0.950 b.Floor Over Other Space R=0.0 1051.00 ft2 None c.other(see details) R= 440.00 ft2 15.Credits Pstat Glass/Floor Area: 0.068 Total Proposed Modified Loads: 74.77 PASS Total Baseline Loads: 74.82 I hereby certify that the plans and specifications covered by Review of the plans and Q,TkTT this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: Dave r4Gol ch Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 herebycertify that this building,as designed, is in compliance Florida Statutes. fY 9, 9w. .with the Florida Energy Code. �D OWNER/AGENT: - BUILDING OFFICIAL: DATE: CHEDATE: r - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.070 Qn for whole house. 2/1/2018 8:15 AM EnergyGaugeO USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5 t FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 2575A1 sf ADS 2017 Builder Name: Lennar Homes Street: 6608 Wagon Trail Street Permit Office: City of Zephyrhills City,State,Zip: Zephyrhills,FL, Permit Number: Owner: Lennar Homes Jurisdiction: 611600 Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) 1. New,construction or existing New(From Plans) 9. Wall Types(2613.1 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1264.00 ft' b.Concrete Block-Int Insul,Exterior R=4.1 996.67 ft' 3. Number of units,if multiple.family 1 c.Frame-Wood,Adjacent R=11.0 352.44 ft' 4. Number of Bedrooms 4 d.N/A R= ft' 5. Is this a worst case? Yes 10.Ceiling Types (1491.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1491.00 ft' 6. Conditioned floor area above grade(W) 2584 b.N/A R= ft' Conditioned floor area below grade(ft') 0 c.N/A R= ft' 11.Ducts R ft' 7. Windows(175.6 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 -218.6 a. U-Factor. Dbl,U=0.54 71.25 ft' b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 298.2 SHGC: SHGC=0.31 b. U-Factor. Dbl,U=0.56 71.00 ft' 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.28 a.Central Unit 18.0 SEER:16.00 c. U-Factor: Dbl,U=0.56 33.33 ft' b.Central Unit 25.2 SEER:16.00 SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft' a.Electric Heat Pump 17.5 HSPF:8.50 SHGC: b.Electric Heat Pump 21.8 HSPF:8.50 Area Weighted Average Overhang Depth: 1.190 ft. Area Weighted Average SHGC: 0.300 14.Hot water systems 8. Floor Types (2584.0 sqft.) Insulation Area a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 1093.00 ft' b. Conservation features EF:0.950 b.Floor Over Other Space R=0.0 1051.00 ft' None c.other(see details) R= 440.00 ft' 15.Credits Pstat Glass/Floor Area: 0.068 Total Proposed Modified Loads: 74.77 PASS Total Baseline Loads: 74.82 I hereby certify that the plans and specifications covered by Review of the plans and - this calculation are in compliance with the Florida Energy specifications covered by this rj Code. calculation indicates compliance!'�,;, '� ,���.�, with the Florida Energy Code. PREPARED BY: Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 herebycertify that this building,as designed,is in compliance Florida,Statutes. fY 9, 9 P _ with the Florida Energy Code. OWNER/AGENT: BUILDING FFICIAI - DATE: DATE: ' - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.070 Qn for whole house. 211/2018 8:15 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 2575A1 sf ADS 2017 Builder Name: Lennar Homes Street: 6608 Wagon Trail Street Permit Office: City of Zephyrhills City,State,Zip: Zephyrhills,FL, Permit Number: Owner. Lennar Homes Jurisdiction: 611600 Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(2613.1 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1264.00 ft2 b.Concrete Block-Int Insul,Exterior R=4.1 996.67 ft2 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 352.44 ft2 4. Number of Bedrooms 4 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (1491.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1491.00 ft2 6. Conditioned floor area above grade(ft2) 2584 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(175.6 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 218.6 a. U-Factor: Dbl,U=0.54 71.25 ft2 b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 298.2 SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.56 71.00 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.28 a.Central Unit 18.0 SEER:16.00 c. U-Factor: Dbl,U=0.56 33.33 ft2 b.Central Unit 25.2 SEER:16.00 SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 17.5 HSPF:8.50 SHGC: b.Electric Heat Pump 21.8 HSPF:8.50 Area Weighted Average Overhang Depth: 1.190 ft. Area Weighted Average SHGC: 0.300 14.Hot water systems 8. Floor Types (2584.0 sqft.) Insulation Area a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 1093.00 ft2 EF:0.950 9 b. Conservation features b.Floor Over Other Space R=0.0 1051.00 ft2 None c.other(see details) R= 440.00 ft2 15.Credits Pstat Glass/Floor Area: 0.068 Total Proposed Modified Loads: 74.77 PASS Total Baseline Loads: 74.82 I hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance /JAG/- with the Florida Energy Code. 'Dave WL PREPARED BY: Before construction is completed DATE: this buildingwill be inspected for - C P compliance with Section 553.908 I herebycertify that this building,as designed, is in compliance Florida Statutes. . fY 9� 9 P with the Florida Energy Code. OWNER/AGENT: BUILDING OF IC L: DATE: DATE: - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.070 an for whole house. 2/1/2018 8:15 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2017 PROJECT V. Title: 2575A1 sf ADS 2017 Bedrooms: 4 = Address Type: Street Address Building Type: User Conditioned Area: 2584 Lot# Owner Name: Lennar Homes Total Stories: 2 Block/Subdivision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: Lennar Homes Rotate Angle: 90 Street: Permit Office: Cross Ventilation: County: Pasco Jurisdiction: Whole House Fan: City,State,Zip: Zephyrhills, Family Type: Single-family FL, New/Existing: New(From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Tampa FL TAMPA_INTERNATI 39 91 70 75 645.5 54 Medium BLOCKS Number Name Area Volume 1 Blockl 1093 9399.8 2 Block2 1491 11928 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 1st Floor 1093 9399.8 Yes 0 1 Yes Yes Yes 2 2nd Floor 1491 11928 No 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio 1st Floor 102 ft 0 1093 ft2 ___ 0.3 0 0.7 2 Raised Floor 2nd Floor -__ 13 ft2 11 0 0 1 3 Floor over Garage 2nd Floor ---_ 427 ft2 11 0.2 0 0.8 4 Floor Over Other Space 2nd Floor 1051 ft2 0 0.2 0 0.8 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1613 ft2 0 ft2 Medium 0.85 No 0.9 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 1489 ft2 N N 2/1/2018 8:15 AM EnergyGaugeO USA-FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2017 CEILING # Ceiling Type Space R-Value ' 'Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) 2nd Floor 30 Bfown 1491 ft2 0.11 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 N=>E Exterior Concrete Block-Int Insul 1st Floor 4.0999 19 8 8 164.7 ft2 0 0.600000 0 2 E=>S Exterior Concrete Block-Int Insul 1st Floor 4.0999 38 8 8 329.3 ft2 0 0.600000 0 _3 S=>W Exterior Concrete Block-Int Insul 1st Floor 4.0999 34 8 8 294.7 ft2 0 0.600000 0 4 W=>N Exterior Concrete Block-Int Insul 1st Floor 4.0999 18 8 8 156.0 ft2 0 0.600000 0. 5 N=>E Garage Frame-Wood 1st Floor 11 20 8 8 173.3 ft2 0 0.01 0 6 W=>N Garage Frame-Wood 1 st Floor 11 20 8 8 8 179.1 ft2 0 0.01 0 7 N=>E Exterior Frame-Wood 2nd Floor 11 40 8 320.0 ft2 0 0.600000 0 8 E=>S Exterior Frame-Wood 2nd Floor 11 39 8 312.0 ft2 0 0.6 0 9 S=>W Exterior Frame-Wood 2nd Floor 11 40 8 320.0 ft2 0 0.600000 0 10 W=>N Exterior Frame-Wood 2nd Floor 11 39 8 0 312.0 ft2 0 0.600000 0 11 S=>W Exterior Concrete Block-Int Insul 1st Floor 4.0999 6 8 8 52.0 ft2 0 0.600000 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N=>E Insulated 1st Floor None .2 3 6 8 20 ft2 2 N=>E Wood 1st Floor None .4 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered orientation => changed to Worst Case. / Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 3 S=>W 11 Metal Low-E Double Yes 0.56 0.32 N 33.3 ft2 2 ft 0 in 0 ft 6 in Drapes/blinds None 4 S=>W 3 Metal Low-E Double Yes 0.54 0.31 N 9.3 ft2 1 ft 0 in 10 ft 0 in Drapesiblinds None 5 N=>E 7 Metal Low-E Double Yes 0.56 0.28 N 16.0 ft2 1 ft 0 in 4 ft 0 in Drapesiblinds None 6 S=>W 9 Metal Low-E Double Yes 0.54 0.31 N 23.0 ft2 1 ft 0 in 0 ft 6 in Drapes/blinds None 7 W=>N 10 Metal Low-E Double Yes 0.54 0.31 N 16.0 ft2 1 ft 0 in 0 ft 6 in Drapes/blinds None 8 N=>E 7 Metal Low-E Double Yes 0.56 0.28 N 32.0 ft2 1 ft 0 in 0 ft 6 in Drapes/blinds None 9 S=>W 3 Metal Low-E Double Yes 0.54 0.31 N 23.0 ft2 1 ft 0 in 10 ft 0 in Drapes/blinds None 10 N=>E 1 Metal Low-E Double Yes 0.56 0.28 N 23.0 ft2 1 ft 0 in 13 ft 0 in Drapes/blinds None GARAGE # - Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 427 ft2 427 ft2 41 ft 8.6 ft 1 i i I 2/1/2018 8:15 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2017 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000367 2488.2 136.6 256.9 .339 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 17.5 kBtu/hr 1 sys#1 2 Electric Heat Pump/ Split HSPF:8.5 21.8 kBtu/hr 2 sys#2 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER:16 18 kBtu/hr 540 cfm 0.85 1 sys#1 2 Central Unit/ Split SEER: 16 25.2 kBtu/hr 756 cfm 0.85 2 sys#2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 40 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model# Collector Model# Area Volume FEF None None ftz DUCTS —Supply— —Return— Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 218.6 ft 2nd Floor 54.65 ft Proposed Qn 2nd Floor —cfm 76.5 cfm 0.07 0.60 1 1 2 Attic 6 298.2 ft 2nd Floor 74.55 ft Proposed Qn 2nd Floor —cfm 104.4 cfm 0.07 0.60 2 2 TEMPERATURES Programable Thermostat:Y Ceiling Fans: CoolingJan Feb Mar Apr May X Jun Jul rj Au Se Oct Nov Dec Heatin Jan �Feb X Mar Apr f May Jun Jul AuJXJ SeP Oct Nov - H DecVentin Jan Feb X Mar [X]A r [ Ma Jun Jul Aug Se Oct HX Nov Dec I I I 2/1/2018 8:15 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2017 Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 --78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 I I 2/1/2018 8:15 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5 FORM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerformance Index, the more efficient the home. Zephyrhills, FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1264.00 ft2 b.Concrete Block-Int Insul,Exterior R=4.1 996.67 ft 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 352.44 ft2 4. Number of Bedrooms 4 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types Insulation Area a.Under Attic(Vented) R=30.0 1491.00 ft2 6. Conditioned floor area(ft2) 2584 b.N/A R= ft2 7. Windows- Description Area c.N/A R= ft2 a. U-Factor: Dbl,U=0.54 71.25 ft2 11.Ducts R ft2 a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 218.6 SHGC: SHGC=0.31 b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 298.2 b. U-Factor: Dbl,U=0.56 71.00 ft2 SHGC: SHGC=0.28 12.Cooling systems kBtu/hr Efficiency c. U-Factor: Dbl,U=0.56 33.33 ft2 a.Central Unit 18.0 SEER:16.00 SHGC: SHGC=0.32 b.Central Unit 25.2 SEER:16.00 d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 17.5 HSPF:8.50 Area Weighted Average Overhang Depth: 1.190 ft. b.Electric Heat Pump 21.8 HSPF:8.50 Area Weighted Average SHGC: 0.300 8. Floor Types Insulation Area 14.Hot water systems a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 1093.00 ft2 EF:0.95 b.Floor Over Other Space R=0.0 1051.00 ft2 c.other(see details) R= 440.00 ft2 b. Conservation features None 15.Credits Pstat certify that this home has complied with the Florida Energy Efficiency Code for Building T1 :ST Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. • Builder Signature: Date: 02/01/18 : ' ` Address of New Hom 6608 Wagon Trail Street City/FL Zip: Zephyrhills,FL 33541 i *Note: This is not Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage'(EEIV inc ntives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge:com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building- Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 2/1/2018 8:17 AM EnergyGauge®USA-FlaRes2017 -Section R405.4.1 Compliant Software Page 1 of 1 Building Analysis Job: 2575A1sf ADS2017 g Y Date: 211/2018 lower floor By: Dave BAYONET PLUMBING COOLING HEATING • - • • For: Lennar Homes Design Conditions Location: Indoor: Heating Cooling Tampa International AP, FL, US Indoor temperature(OF) 70 75 Elevation: 10 ft Design TD (OF) 39 16 Latitude: 28°N Relative humidity(%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 34.7 54.7 Dry bulb(OF) 31 91 Infiltration: Daily range(OF) - 14 ( L ) Method Simplified Wet bulb(°F) - 77 Construction quality Semi-tight Wind speed (mph) 15.0 7.5 Fireplaces 0 Component Btuh/ft2 Btuh % of load Walls 5.5 5179 31.9 °c Glazing 30.2 2683 16.5 nfiltration Doors 21.2 419 2.6 wall Ceilings 1.8 57 0.4 Floors 4.1 4478 27.6 Infiltration 1.9 2032 12.5 Ducts 1400 8.6 Piping 0 0 Floors Humidification 0 0 Glazing Ventilation 0 0 Doors Other Adjustments 0 Total 16249 100.0 Component Btuh/ft2 Btuh % of load Walls 2.8 2632 23.2 Internal Gains Glazing 56.3 5004 44.1 Wall Doors 16.6 328 2.9 Ceilings 2.0 64 0.6 ucts Floors 0 0 0 Infiltration 0.4 453 4.0 Ducts 1655 14.6 Infiltration Ventilation 0 0 Other Internal gains 1200 10.6 Doors Blower 0 0 Adjustments 0 Glazing Total 11336 100.0 Latent Cooling Load= 1233 Btuh Overall U-value= 0.150 Btuh/ft2-°F Data entries checked. t -�- wrightsoft9 2018 Feb-01 08: e 1 �� Right-Suite®Universal 2017 17.0.23 RSU05714 Page 1 ..BA27UHE AH's\2575Asf ADS template 1.5-2ton.rup Calc=MJ8 Front Door faces: W Building Anal Job: 2575A1sf ADS2017 g ySIS Date: 2/1/2018 upper floor By: Dave BAYONET PLUMBING COOLING HEATING Project Information For: Lennar Homes Design Conditions Location: Indoor: Heating Cooling Tampa International AP, FL, US Indoor temperature(OF) 70 75 Elevation: 10 ft Design TD (OF) 39 16 Latitude: 28°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 34.7 54.7 Dry bulb(OF) 31 91 Infiltration: Daily range(OF) - 14 ( L ) Method Simplified Wet bulb(OF) - 77 Construction quality Semi-tight Wind speed(mph) 15.0 7.5 Fireplaces 0 ME • Component Btuh/ftz Btuh % of load Walls 3.8 4219 32.8 ucts Glazing 30.2 2608 20.3 Doors 0 0 0 Wall Ceilings 1.3 1870 14.6 nfiltration Floors 0 0 0 Infiltration 1.9 2307 17.9 Ducts 1846 14.4 Piping 0 0 j Humidification 0 0 Glazing Ceilings Ventilation 0 0 Adjustments 0 Total 12850 100.0 Mal • Component Btuh/ftz Btuh % of load Walls 2.7 3046 15.9 Walls Glazing 52.7 4554 23.7 Doors 0 0 0 Internal Gains Ceilings 1.7 2586 13.5 Floors 0 0 0 Infiltration 0.4 514 2.7 Ducts 2137 11.1 Glazing Ventilation 0 0 Internal gains 6380 33.2 Blower 0 0 Adjustments 0 Ducts i Total 19217 100.0 Ceilings Infiltration Latent Cooling Load=2645 Btuh { Overall U-value= 0.083 Btuh/ftz-°F Data entries checked. wrightsoft® 2018-Feb-01 08:31:51 ACCA Right-Suite®Universal 2017 17.0.23 RSU05714 Page 2 ...BA27UHE AH'sX2575Asf ADS template 1.5-2ton.rup Calc=MJB Front Dcor faces: W Project Summary Job: 2575A1 sf ADS 2017 1 •y Date: 2/1/2018 lower floor By: Dave BAYONET PLUMBING COOLING HEATING Project Information For: Lennar Homes Notes: Design Information Weather: Tampa International AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 31 OF Outside db 91 OF Inside db 70 OF Inside db 75 OF Design TD 39 OF Design TD 16 OF Daily range L Relative humidity 50 % Moisture difference 55 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 14848 Btuh Structure 9681 Btuh Ducts 1400 Btuh Ducts 1655 Btuh Central vent (0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 16249 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 11336 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 939 Btuh Ducts 294 Btuh Central vent(0 cfm) 0 Btuh Heating coolingg (none) Area 1093 1093 Equipment latent load 1233 Btuh Volumee(ft') 9638 9638 Air changes/hour 0.29 0.16 Equipment Total Load (Sen+Lat) 12569 Btuh Equiv.AVF(cfm) 47 25 Req. total capacity at 0.85 SHR 1.1 ton Heating Equipment Summary Cooling Equipment Summary Make Lennox Make Lennox Trade 14HPX SERIES Trade 14HPX SERIES Model 14HPX-018-230-21 Cond 14HPX-018-230-21 AHRI ref 10258596 Coil CBA27UHE-018-230*++TDR AHRI ref 10258596 Efficiency 8.5 HSPF Efficiency 13.0 EER, 16 SEER Heating input Sensible cooling 16915 Btuh Heating output 17100 Btuh @ 47°F Latent cooling 2985 Btuh Temperature rise 26 OF Total cooling 19900 Btuh Actual air flow 600 cfm Actual air flow 600 cfm Air flow factor 0.037 cfm/Btuh Air flow factor 0.053 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.90 Capacity balance point= 31 OF Backup: Input=4 kW, Output= 15295 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. �- Wrt htsoft- 2018-Feb-0108:31:51 9 Right-Suite®Universal 2017 17.0.23 RSU05714 Page 1 ...BA27UHE AH's\2575Asf ADS template 1.5-2ton.rup Calc=MJ8 Front Door faces: W Project Summary Job: 2575A1 sf ADS 2017 ry Date: 2/1/2018 upper floor By: Dave BAYONET PLUMBING COOLING HEATING Project Information For: Lennar Homes Notes: DesignInformation Weather: Tampa International AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 31 OF Outside db 91 OF Inside db 70 OF Inside db 75 OF Design TD 39 OF Design TD 16 OF Daily range L Relative humidity 50 % Moisture difference 55 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 11004 Btuh Structure 17080 Btuh Ducts 1846 Btuh Ducts 2137 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 12850 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 19217 Btuh i Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 2266 Btuh Ducts 379 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling (none) Area(ft2) 1491 1491 Equipment latent load 2645 Btuh Volume(ft') 11928 11928 Air changes/hour 0.27 0.14 Equipment Total Load (Sen+Lat) 21862 Btuh Equiv.AVF(cfm) 54 29 Req. total capacity at 0.85 SHR 1.9 ton Heating Equipment Summary Cooling Equipment Summary Make Lennox Make Lennox Trade 14HPX SERIES Trade 14HPX SERIES Model 14HPX-024-230-21 Cond 14HPX-024-230-21 AHRI ref 10258598 Coil CBA27UHE-024-230*++TDR AHRI ref 10258598 Efficiency 8.5 HSPF Efficiency 13.5 EER, 16 SEER Heating input Sensible cooling 21420 Btuh Heating output 21800 Btuh @ 47°F Latent cooling 3780 Btuh Temperature rise 25 OF Total cooling 25200 Btuh Actual air flow 800 cfm Actual air flow 800 cfm Air flow factor 0.062 cfm/Btuh Air flow factor 0.042 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.88 Capacity balance point= 17 OF Backup: Input= 3 kW, Output= 11787 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 1 Wrl htsoftm 2018-Feb-0108:31:51 .-�- 9 Right-Suite®Universal 2017 17.0.23 RSU05714 Page 2 ��` ...BA27UHE AH's\2575Asf ADS template 1.5-2ton.rup Calc=MJ8 Front Doorfaces: W Manual S Compliance Report Job: 2575A1 sf ADS 2017 Date: 211/2018 lower floor By: Dave BAYONET PLUMBING COOLING HEATING Project Information For: Lennar Homes Cooling Equipment Design Conditions Outdoor design DB: 91.3°F Sensible gain: 11336 Btuh Entering coil DB: 75.8°F Outdoor design WB: 77.3°F Latent gain: 1233 Btuh Entering coil WB: 62.9°F Indoor design DB: 75.0°F Total gain: 12569 Btuh Indoor RH: 50% Estimated airflow: 600 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: SplitASHP Manufacturer: Lennox Model: 14HPX-018-230-21+CBA27UHE-018-230*++TDR Actual airflow: 600 cfm Sensible capacity: 15300 Btuh 135% of load Latent capacity: 2700 Btuh 219% of load Total capacity: 18000 Btuh 143% of load SHR: 85% i Heating Equipment Design Conditions Outdoor design DB: 30.8°F Heat loss: 16249 Btuh Entering coil DB: 69.6°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Lennox Model: 14HPX-018-230-21+CBA27UHE-018-230*++TDR Actual airflow: 600 cfm Output capacity: 17500 Btuh 108% of load Capacity balance: 31 OF Supplemental heat required: 0 Btuh Economic balance: -99 OF Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 600 cfm Output capacity: 4.5 kW 94% of load Temp. rise: 50 OF Meets are all requirements of ACCA Manual S. .. wri htsoft* 2018-Feb-0108:31:51 �, 9 Right-Suite®Universal 2017 17.0.23 RSU05714 page 1 14C4:;k ...BA27UHE AH's\2575Asf ADS template 1.5-2ton.rup Calc=MJ8 Front Doorfaces: W Manual S C6mpliance Report Job: 2575AI sf ADS 2017 Date: 211/2018 upper floor By: Dave BAYONET PLUMBING COOLING HEATING Project Information For: Lennar Homes Cooling Equipment Design Conditions Outdoor design DB: 91.3°F Sensible gain: 19217 Btuh Entering coil DB: 75.6°F Outdoor design WB: 77.3°F Latent gain: 2645 Btuh Entering coil WB: 62.8°F Indoor design DB: 75.0'F Total gain: 21862 Btuh Indoor RK 50% Estimated airflow: 800 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Lennox Model: 14HPX-024-230-21+CBA27UHE-024-230*++TDR Actual airflow: 800 cfm Sensible capacity: 21420 Btuh 111% of load Latent capacity: 3780 Btuh 143%of load Total capacity: 25200 Btuh 115% of load SHR: 85% • Equipment Design Conditions Outdoor design DB: 30.8°F Heat loss: 12850 Btuh Entering coil DB: 69.6°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Lennox Model: 14HPX-024-230-21+CBA27UHE-024-230*++TDR Actual airflow: 800 cfm Output capacity: 21800 Btuh 170%of load Capacity balance: 17 OF Supplemental heat required: 0 Btuh Economic balance: -99 OF Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 800 cfm Output capacity: 3.5 kW 92% of load Temp. rise: 50 OF Meets are all requirements of ACCA Manual S. 2018-Feb-M 08:31:51 wrilghtSOft' Right-Suitee Universal 2017 17.0.23 RSU05714 Page 2 ...BA27UHE AH's\2575Asf ADS template 1.5-2ton.rup Calc=MJ8 FrontDoorfaces: W 5335 -8TH STREET (813)780-0020 CERTIFICATE OF OCCUPANCY Address: 6608 WAGON TRAIL ST Owner: LENNAR HOMES LLC ZEPHYRHILLS, FL. 4600 W CYPRESS ST STE 200 Subdiv: SILVERADO TAMPA FL 33607-4099 Parcel: 05-26-21=0080-00600-0080 Work Type: 101-NEW CONST/SFR Construction Type: NOT APPLICABLE 0 Sprinklers Use Classification: NOT APPLICABLE Permit Number: 19503 Date- 7/12/2018riv I ISSUED w' usr 6 ` f. GARBAGE D E CHANGED OVER Wl'*,, AuxD/ F�SIT AMU ST BE APPLIE DAYS op OFF/C/,gLl,• p�� FtSSUa � R jplss NCF ��NCE ppppppp�