Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
18-19508
CITY OF ZEPHYI,IiICLS 5335-8TH STREET (813)780-0020 1 19508 BUILDING PERMIT SINGLE:-FAMILY RESIDENTIAL PERMIT INFORMATION - =. : -LOCATION INFORMATION Permit#:19508 Issued: 4/02/2018 Address: 6670 PADEN WHEEL ST Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Ld't( Block: Section: Sq. Feet: Est. Value: Book:- Page: Cost: 264,422.75 Total Fees: 11,835.69 Subdivision: SILVERADO Amount Paid: 11,835.69 Date"Paid: 4/02/2018 Parcel Number: 05-26-21-0070-00300-0050 CONTRACTOR INFORMATION OWNER INFORMATION Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC Addr: 4600 W. CYPRESS ST STE 200 Address: 4600 W CYPRESS ST STE 200 TAMPA, FL. 33607 TAMPA FL 33607-4099 Phone: (813)5747-5743 Lic: Phone: Work Desc: CONSTRUCT SINGLE FAMILY 3,235 SQ FT APPLICATION?FEES BUILDINZFEE 1,388.65 ELECTRICAL FEE 288.68 PLUMBING FEE 192.45 MECHANICAL FEE 134.72 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES SF . 769.56 SCHOOL IMPACT FEE-sfr/100% 4,828.00 SCHOOL IMPACT FEE-sfr/1% 48.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32 Inspections Re uir.' FOOTER 2ND ROUGH PLUMB MISC--m INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such-as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. 16 rA fffl)_At4�� CO RACTORS SIGNATURE PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER `t�v City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: . e—A✓V&r Date Received: G 9-26—( Site: lP 7 D / QGx 1 aYI-ef'-! �Z Permit Type: ,'A y z/ 'G Approved w/no comments:❑ Approved w/the below comments: Denied w/the below comments: ❑ This comment sheet shall be kept with the permit and/or plans. 1.2 Kalvin S x er— s Examiner Date ontractor and/or Homeowner (Required when comments are present) s Lennar Homes-6670 Paden Wheel St - 3;235 sq ft Column ts SQ. FEET PRICE MAIN OR LIVING: 3,235:' $ 112.65 OTHER AREA UNDER ROOF: , - $ 88.00 OTHER: VALUATION $ 364,422.75 FEE SHEET $ 1,283.00 ADDRESS $ 40.00 DRIVEWAY $ 40.00 BUILDING: $ 1,388.66 ELECTRICAL: $ 288.68 PLUMBING: $ 192.45 MECHANICAL: $ 134.72 SUB-TOTAL $ 2,004.50 TOTAL $ 2,004.50 SEWER: na WATER: na IRRIGATION: $ - TOTAL: $ - WATER METER: na IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 2,557.85 PARK IMPACT FEES $ 769.56 SIF'S: $ 4,828.00 100.0% $ 4,828.00 1.0% $ 48.28 TOTAL: $ 4,876.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 11,835.69 PASCO COUNTY, FLORIDA Permit No, f f Date Permitted Z Builder Name/Owner Name G P�cf l,�r—f or/Jtzg�lsdc Control#' County Parcel No. ©5-�-2f- ZCYdy�D6—! SubDiv: Address/Location (P 0 2n Ciassification/Type of Use TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: _ Exempt �Yes ❑ No How Determined ,;.. : impact Fee Amount $. r 632 a Zone No, TAZ: SCHOOL IMPACT FEE rPt/ Account (056) Single-Family Detached House Amount $ 7 $ 26- (057) Mobile Home (058) Other Residential { 123) Collection Fee Exempt [ Yes ❑ No How Determined PARKS AND RECREATION FEE Land Account Land Credit Land Total Recreation Account Recreation Credit -Recreation Total Zone TOTAL AMOUNT $ `6ni_�kf Exempt ❑Yes [] No How Determined LIBRARY FEE 4; . Land Account Land Credit Land Total Facility Account Facility Credit Facility Total Exempt ❑Yes ❑ No How Determined Total Amoaq RESOURCE FEE ERU TOTAL AMOUNT Prepared By Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY Acknowledgement below does not Imply acceptance of concurrence,but simply receipt of a copy of this form,placing . + the building permit owner on notice of this assessment and thQ conditions of payment for same. DATE RECEIVED BY RECEIPT NO. - DATE BY I(IIIII IIIII IIIII IIIII IIIII IIIII IIIII IIIII IIIII IIIII llll(III 2018053290 Rcpt:1944465 Reo: 10'00 DS: 0.00 IT: 0.00 Clerk 04/02/2018 K. A. , DptY — - - PAULA S.o'NEIL,�Ph.D.PASco CLERK & coMPTROLLEV% 04 OR K 1 r i m PG - - Permit No. Parcel ID No 05-26-21-0070-00300-0050 NOTICE OF COMMENCEMENT State of Florida County of Pasco THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement: 1. Description of Property: Legal SILVERADO RANCH SUBDIVISION PHASES 2,3,&4 PB 73 PG 59 BLOCK 03 LOT 05 Street Address: 6670 Paden Wheel Street Zephryhills FL 33541 2. General Description of Improvement Single Family Residence/Pool/Screen Enclosure/Fence 3. Owner Information: Lennar Homes, LLC. Name 4600 W Cypress St. Ste 200 Tampa FL. 33607 Address City State Interest in Property: Name of Fee Simple Titleholder: N/A (If other than owner) Address City State 4. Contractor: Lennar Homes, LLC Name 4600 W Cypress St, Ste 200 Tampa FL, 33607 Address City State Contractor's Telephone No.: 813.574.5700 5. Surety: 1 N/A Name Address City State Amount of Bond: $ Telephone No.: 6. Lender: N/A Name Address City State Lender's Telephone No.: 7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)(7),Florida Statutes: Lennar Homes, LLC Name 4600 W Cypress St, Ste 200 Tampa FL, 33607 e Address City State Telephone Number of Designated Person: 813.574.5700 8. In addition to himself,the owner designates N/A of to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statutes. Telephone Number of Person or Entity Designated by Owner: 9. Expiration date of Notice of Commencement is one year from the date of recording unless a different date is specified: WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. STATE OF FLORIDA COUNTY OF PINELLAS l� Signature of Owner or Owner's Authorized Officer/Director/Partner/Manager Vice President Signatory's Title/Office The foregoing instrument was acknowledged before me this 6 day of March ,by Steve Robert Smith as Vice President (type of authority- cer,trustee,attorney in fact)for Lennar Homes LLC name of party o beha om instrument was executed). Personally Known®OR Produced Identification Notary S nature Type 8f Identification'Produced Name(Print) Elissa Holleran Verification pursuant to Section 92,525,Florida Statutes. Under penalties of perjury,I declare that I have read the foregoing and that the facts stated in it are true,to the best of my knowledge and belief.. WSW.HOLLERAN Signature of Natural Person Signing Above COMMI1110e N FF 085837 'o'=Ex�Ires June E;2020• wpdata/bbs/bcsformi � Pr;, llondWl6iroy alhIMurnnee100 19 STAFF OF FLORIN]¢ ,COUNTY OF PASCO ©®� THIS IS TO CERTIFY-THAT THE FOREGOING IS A t��• „ . : TRUE AND CORRECT COPY OF THE DOCUMENT r . ON FILE OR OF PUBLIC RECORD IN THIS OFFICE In god We T"wt WITNESS MY HAND AN OFFICIAL SEAL THIS � DAY OF 2 S.O'NEIL,CR &ik-, _ Q, °�®�®®�' BY � ''�' DEPUTY CLERK 8137780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received Phone Contact for Permitting 813 363 _ 2891 9 1 1 1 1 1 1 1 1 1 1 1 1 1 K I r I I t t Owner's Name Lennar Homes,LLC e Owner Phon Number r813.574.5700 Owner's Address 1 4600 W.Cypress St.Ste.200,Tampa,FL 33607 Owner Phone Number Fee Simple Titleholder Name N/A Owner Phone Number Fee Simple Titleholder Address N/A JOB ADDRESS 6670 Paden Wheel Street LOT 0050 SUBDIVISION Silverado Ranch Subdivision Ph 2,3,&4 PARCEL ID# 05-26-21-0070-00300-0050 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR B ADD/ALT SIGN Q DEMOLISH P INSTALL REPAIR PROPOSED USE SFR 0 COMM = OTHER TYPE OF CONSTRUCTION BLOCK = FRAME = STEEL = DESCRIPTION OF WORK Single Family Residence/Pool/Screen Enclosure/Fence BUILDING SIZE I U/R SF 3235 SQ FOOTAGE 2421 HEIGHT 1 Story BUILDING Is C�I j+ VALUATION OF TOTAL CONSTRUCTION ELECTRICAL $ J AMP SERVICE ® PROGRESSENERGY Q W.R.E.C. ��� 0PLUMBING $ v MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION l (/ =GAS ROOFING 0 SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES Do BUILDER COMPANY [Enn:ar Homes,LLC SIGNATURE A_ REGISTERED Y/ N FEE CURREN Address 4600 W.Cypress St.St .200,Tampa,FL 33607 License# __CGC1518166 ELECTRICIAN COMPANY Edmonson Electric, Inc. SIGNATURE REGISTERED Y/ N FEE CURREN -1 1 Address 1034 Skipper Road, Tampa, FL 33613 License# EC13005408 PLUMBER COMPANY Bayonet Plumbing, Heating &AC, Inc SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address P.O. Box 5308, B yonet, FL 34674-5308 License# CFC042998 MECHANICAL COMPANY Bayonet Plumbing, Heating & AC, Inc SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address P.O. Box 5308, Ba onet, FL 34674-5308 License# CAC058062 OTHER COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Address 4211-Shoal Line d,'Spring Hill, FL 34607 License# CCC057991 IIIIIt1111111t1111 Illlllllllllllllllllllllllllllllllltllllllllllll RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. . . L■" Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement Is required. (A/C upgrades over$7500) ** Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW '/ NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. ' UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work,.they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner" prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water[Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone W" unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect'adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the.permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT FLORIDA JURAT(F.S. 117.03) OWNER OR AGENT CONTRACTOR Subscribed and sworn to(or affirmed)before this Subscribed and sworn to(or affir ed)before me this Un-vct—1 1 by Paul Sweeney 06-0d-17 b Paul Swee Y _Who is/are personally known to me or Fe p—d-Ged Who is/are ersonall known me or hasihave pfeddue as identif ation. as identification. Notary Public Notary Public Commission No. FF98537 Commission No. FF98537 Elissa M.Holleran Elissa M.Holleran Name of Notary tvped.printed or stamped Name of Notary typed,printed or stamped Oil 1�lIR11i71�"6flIU;I?(��E�B9� i ��.MB��dIteVBi��d bnndW7%NTkrykil,tvug4541k'41MII Lennar Homes-6670 Paden Wheel St-.3235 Column ts SQ. FEET PRICE MAIN OR LIVING: 3,235 $ 112.65 OTHER AREA UNDER ROOF: =- $ 88.00 OTHER: - $ - VALUATION $ 364,422.75 FEE SHEET $ 1,283.00 ADDRESS $ 40.00 DRIVEWAY $ 40.00 BUILDING: $ 1.388.66 ELECTRICAL: $ 288.68 PLUMBING: $ 192.45 MECHANICAL: $ 134.72 SUB-TOTAL $ 2,004.50 TOTAL $ 2,004.50 SEWER: n/a WATER: n/a IRRIGATION: $ - TOTAL: $ - WATER METER:1 n/a IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 2,557.85 PARK IMPACT FEES $ 769.56 SIF'S: $ 4,828.00 100.0% $ 4,828.00 1.0% $ 48.28 TOTAL: $ 4,876.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 11,835.69 05-26-21-0070-00300-0050 Pasco County Property Appzaiser Page 1 of 1 Data Current as Of: Weekly Archive;;; Saturday, February 10, 2018 Parcel ID 05-26-21-0070-00300-0050 (Card: 001 of 001) Classification 00 - Vacant Residential Mailing Address Property Value DUNE FL LAND I SUB LLC - Ad Land $0 C/O HAWK MANAGEMENT CO LLC Land $26,116 2502 N ROCKY POINT DR STE 1050 Building $0 ROCKY POINT FL 33607-5995 Extra Features $0 Physical Address 6670 PADEN WHEEL STREET ZEPHYRHILLS, FL 33541 Just Value $26,116 Assessed (Non-School Amendment 1) $26,116 Legal Description (First 4 Lines) See Plat for this Taxable Value $26,116 Subdivision SILVERADO RANCH SUBDIVISION PHASES 2, 3 &4 PB 73 PG 059 BLOCK 3 LOT 5 Jurisdiction City of Zephyrhills _ Land Detail (Card: 001 of 001) _ Line Use Description Zoning _;Units _ Type jPrice _ Condition Value 1 _� 0100 SFR �_ MPUD 6,000.00 SF $4.25 1.00 $25,500 2 j 0100 SFR MP iDU 1,539.00 SF $0.40 �1.00( $616 _Additional Land Information Acres 0.17 Tax Area 30SI -- Residential Code SLVRLPI j 7 Code I Building Information - Use 00 - Unimproved (Card: 001 of 001) Unimproved Parcel 00 - Unimproved Extra Features (Card: 001 of 001) Line _ uDescription — - 1Year _ Units — (Value No Extra Features Sales History- See All 5 sales Previous Owner: Month/Year _Book/Page _ T_ype DDOR—Code �Conditi_ Ano mount —_ 09/2011 8606 / 3376 _ Warranty Deed _! 05 Vacant Multi-Parcel Sale_ — — — — — -- 05/2010 _8373 / 1912 Certificate of Title _ _ $0 _;_ 12— j Vacant 07/2005 6725 / 1059` Quit Claim Deed Vacant j $0 http://search.pascopa.com/parcel.aspx?parcel=2126050070003000050 2/12/2018 SKETCH ONLY SEC. 05 , TWP. 26 S, RNG. 21 E. PLOT PLAN NOT A BOUNDARY SURVEY LOT 5,, BLOCK 3 BEARING BASIS: SILVERADO RANCH SUBDIVISION NORTH BOUNDARY OF SE1% OF 05-26-21 BEING N 89'25'01" E PHASES 2, 3 & 4 THIS SURVEY IS SUBJECT TO ANY FACTS THAT PASCO COUNTY, FLORIDA. MAY BE DISCLOSED BY A FULL AND ACCURATE TITLE SEARCH. ALSO SUBJECT TO SETBACKS, PRELIMINARY DRAWING' EASEMENTS AND RESTRICTIONS OF RECORD. THIS PLAN IS FOR PERMITTING PURPOSES psi UNDERGROUND FOOTER, STEM WALL, AND ONLY, NOT FOR CONSTRUCTION. VERIFY ALL DIMENSIONS BEFORE ANY CONSTRUCTI UNDERGROUND UTILITIES ARE NOT LOCATED OR ON. II SHOWN. LEGEND: w DO NOT SCALE THIS PRINT. DIMENSIONS AND f-�= PROPOSED DRAINAGE FLOW \ —PCP(P) < NOTES TAKE PREFERENCE. (00.00) = PROPOSED GRADE rn E-00.00 = EXISTING GRADE DESCRIPTION NOT CONTAINING PLAT BOOK AND PAGE INDICATES THAT PLAT IS IN NOTES' PRELIMINARY STAGE AND IS SUBJECT TO LOT GRADING TYPE = A CHANGE AND/OR REVISION. PROPOSED PAD ELEVATION = 108.2' !-� CERTAIN DATA SHOWN HEREON BASED ON FRONT SET BACK = 20' !_`�/ / \ ENGINEERING PLANS PROVIDED BY CLIENT. SIDE SET BACK = 7.5' Q`(/ REAR SETBACK = 15' STRUCTURE TIES SHOWN HEREON DENOTES MEASUREMENT FROM FORM BOARDS/FOUNDATION TO PROPERTY LINE. 10' UTILITY EASEMENT C137 . r80 '1� C, 190 �� \ \ ��F - p, a..- ..... O. TRA T• LAND C P,E'.:. 7 \ EASEMENT C 147 /• �,�'•' IrIQ PCP(P) m -• J ^yo pQ i�F g.y ari 1. \ A�. 9�0 h \ 'Sp:•. (108.80')\ •\ 'e°o° O \ LOT 6 0� \ BLOCK 3 7JS9 P�C' \ \ 5r' ON LOT AREA CALCULATIONS .'-?YS �� LOT = 7539.04 SQ. FT. ° M LIVING.AREA = 2421 SQ. FT. LOT 4 ENTRY = 132 SQ. FT. BLOCK 3 N GARAGE = 574 Q. FT. r i COVERED LANAI = 108 SQ. FT. '2 PATIO =--Nj-A SQ. FT. CONC. DRIVE = 571 Q. FT. o A/C & CONC PAD = 9 Q. FT. R PRIVATE SIDEWALK = 57 SQ. FT. IMPERVIOUS =51 9 rn = 3872 sQ. FT. PROPOSED: SOD = 3667 s0. FT. LOWEST FLOOR ELEVATIONS: OFF LOT AREA CALCULATIONS DESCRIPTION: LIVING AREA: 108.90' RIGHT OF WAY = 1209.23 SQ. FT. GARAGE AREA: r%7 DRIVE APRON = 350 SQ. FT. LOT 5, BLOCK 3, MAP OR PLAT ENTITLED "SILVERADO ELEVATIONS REFERENCED TO Y PUBLIC SIDEWALK = 329 SQ. FT. RANCH SUBDIVISION PHASES 2, 3 & 4", AS RECORDED NORTH AMERICAN VERTICAL m SOD = 530 SQ. FT. .4- IN PLAT BOOK 73, PAGES 59 THROUGH 65, OF THE DATUM OF 1988. MEAN SEA TOTALS PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. LEVEL= 00.00 FT. N AREA = 8748.27 SQ. FT. d DRIVEWAY = 921 SQ. FT. CURVE RADIUS ARC CHORD BEARING DELTA SIDEWALK = 386 SQ. FT. C137 25.00' 5.03' 5.03' N 47'32'46" E 1132'13" c=i SOD = 4197 SQ. FT. C147 1 277.00' i 5.87' 5.87' N 41'10'13" E 1 01'12'54" z o APPARENT FLOOD HAZARD ZONE: "X" COMMUNITY PANEL NO. 120230 0455 D EFFECTIVE DATE: 09/30/1992 LEGEND: j (C)= CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, q= CENTERLINE, A/C= AIR CONDITIONER, B/C= BACK OF CURB, C/S= N CONCRETE SLAB, CH= CHORD, CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= COVERED, E/P= EDGE OF PAVEMENT, ESM'T= EASEMENT, /F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE, FIR= FOUND IRON ROD, FN&D= FOUND NAIL & DISK, FPP= FOUND PINCHED u PIPE, LFE= LOWEST FLOOR ELEVATION, MAS.= MASONRY, OR= OFFICIAL RECORD BOOK, PB= PLAT BODKf�Ca=:PERMANENT CONTROL POINT, PRM=.PERMANENT a REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & CAP No. 4493;-SN&D=,'SSE-T-NXIL"-&-DISK, TBM= TEMPORARY BENCHMARK, U/P= UTILITY POLE, W F= WOOD FENCE, R) = RADIAL a JOHN R.BEACH&ASSOCIATES,INC. Drawn By. SMS Square?Feei 7539;04 LENNAR HOMES SURVEYORS AND MAPPERS w Checked By. 911 WEST ST. PETERSBURG DRIVE JRB in ONE OLDSMAR, FLORIDA 34677 o WAY 813 854-1276 FAX 813 855-8370 Scale: 1.1 _ L-� .` 1 ^ •� NOT VALID WITHOUT THE SIGNATURE AND Date: PLOT PLAN 9 19 17 ACS v THE ORIGINAL RAISED SEAL OF A FLORIDA JON-ks,BEACH - DATE -00 LICENSED SURVEYOR AND MAPPER YLORIDAXG. LAND-SURVEYOR No. 2984 LB#4493 V) - - / Revisions: 05-26-21-0070-00300-0050 Pasco County Property Appraiser Page 1 of 1 Data Current as Of: Weekly Archive - Saturday, March 24, 2018 Parcel ID 05-26-21-0070-00300-0050 (Card: 001 of 001) Classification 00:-:Vacant Residential Mailing Address Property Value LENNAR HOMES LLC Ag Land $0 4600 W CYPRESS ST STE 200 Land $24,616 TAMPA FL 33607-4099 Building $0 Physical Address Extra Features $0 6670 PADEN WHEEL STREET ZEPHYRHILLS, FL 33541 )ust Value $24,616 Legal Description (First 4 Lines) Assessed (Non-School Amendment 1) $24,616 SILVERADO RANCH SUBDIVISION PHASES 2, 3 &4 PB 73 PG 059 BLOCK 3 Taxable Value $24,616 LOT 5 Jurisdiction City of Zephyrhills Land Detail (Card: 001 of 001) Line Use Description}Zoning Units _�Type _jPrice�—'Condition (Value 1— 0100 SFR MPUD 6,000.00 iiI�- SF _$4.00 1.00 _j ?4,000 2 j 0100 SFR MPUD 1,539.00I SF $0.40. 1.00 ! $616 Additional Land Information Acres 0.17 (Tax Areal 30SI FEMA~ Residential Code ' SLVRLPI Code �`--. Building Information - Use 00 - Unimproved (Card: 001 of 001) Unimproved Parcel 00 - Unimproved Extra Features (Card:_ 001 of 001) Line T!___IDescription _Year — jUnits _ .,Value— _ No Extra Features Sales History-See All 6 sales Previous Owner: DUNE FL LAND I SUB LLC Month/Year Book/Page -Type _ _ DOR Code (Condition (Amount — 03/2018- 9694 / 3124---�1 Warranty Deed 05 Vacant Multi-Parcel Sale_ 09/2011 _ 8606 / 3376 I,— Warranty Deed 05 Vacant Multi-Parcel Sale 05/2010 8373 / 1912 , Certificate of Title 12 Vacant $0 http://search.pascopa.com/parcel.aspx?parcel=2126050070003000050 4/2/2018 Sin le , it D —11m Y . Plan Review Comments I. F.F.E. shall be a minimum of 8- above.the road.elevation'and an engineered site plan. 2. Lots shall be graded to comply with R401.3 of the F.B;C. 3.' ,Compaction_test required-if 24" or more of ,fill dirt is.brought in at any one place. . .4: :Tie in' survey required before pouring concrete.. :..5. Driveways:require a R:O.W. use permit:: All 4 sides of driveway thru the sidewalk shall have :expansion material:. . : 6.. All setbacks.shall be,met... 7.: :All property:markers shall be.uncovered and'marked at time of first.inspection: 8:. All A.D.A.-requirements shall be met. 9. No electric;plumbing,:mechanical;,or framing shall be:covered without an inspection and approval first. 10. All.Garages shall.comply;with.section R302;6 of the.F.B:C..(Fire S:eparation). 11.Appliances;shall�not:be installed in a location where subject to mechanical'damage unless piotected byapproved_barriers. -M303.4 of the RB:C. 12. Water heaters shall p .corn l: :with section P607.3 of the F.R.C. Y . 13. Foundation supports for.A/C units.shallbe raised at Least 3" above finished-grade, M1309.1. 14. Return air in all,:bedrooins..F.B.C. M1620.4,, 15. Smoke detectors are.to be installed-in'i accordance with:R313:1 of the:RB.C. 16.::A11 glazing requirements are:.to be in accordance with R308.4,of the F.B:C. 17. All means of egress are to be in:accordance with-R3I t6f the F:B.0 18. `-`Green gypsum board shall not be-used:as a backer.in showers or tubs.R702.4:2 F.B.C. 19. Combination-.type AFCI breakers are,required at all.locations requiring an AFCI,type breaker: 20. Carbon monoxide alarms will.be re wired in.new-construction that uses fossil-burniri heatin q . . . g. . g :or appliances or an attached garage:, They shall be.installed in accordance with the F.B.C:. 21. All plumbing;mechanical,:and electrical shall:be separate from unit_to:unit: This includes all. underground:plumbing and electric: 22. All 2008.N:E:C: Codes.will be enforced: 23.Tamper=Resistant Receptacles in accordance with 406:1 l of the 2008 N.E.0 24,: In accordance:with the Land.Development Code, lots.shall be.sodded before final at least 10 feet:around the structure: 25 A.Copy of the energy cacls shall be with permitat all times. 26 Copy of rnal.insulation report shall be-provided with.permit before fMA - F:F:E.-Finished Floor.Elevation. F.B:C- Florida Building Code 5'h Edition:: R.O.W.-Right of Way A.D.A.-Americans with,Disabilities Act N.E.C.-National Electric Code(2008)- YQQR `------------------- 'x hb iN NO o ,n� t�• ��{ t 70 F LQ a S8 y.© t ` \� O..p..:r;,`\ �'1� +���� < ' �t•'t L4T to 'f r r .4s. 7 � -'!- 0 J �� �StDaS a -�� - .~�� Q � ,` •YY.�� 'd� 4 �',�° . .' ,as.,e � `, ;. �v ��' P��S 0,8=� •t '$ : _ `' ^• `��o�` ,4� 't,�0. �" �'��. ^A' ',+�;,, .n9,', p "''� ~fJ ^'Z - J �.. �7E A \``• �,\-F �, .per\` ,;� .�. a 5"' / � :,L-OT, S 8.2'. 1 'i' Jr C mR� "e� .^•� \ �J_, ?�{>�Q r --- FF`PT pADpp "V' _��'a`b` ti 'J •��` << �±. a 4• `, ,.pAD=1 p8.3 '�-.. r 1� �'' 4gas��• rJ -i- r ,' 07 s3 �J TYPE B r' t `b Lo r�b' P 0PE FF'"S7 4� t �' p`� r� � FFcS09 20 r a y A PAS SO.2 tt i_ F�' PAD PE; tt t tt -5.1 �t �� .76 ��CS 109.3 4 r 109.3 t n. -109.h� t t ^Og.90 FpT; 7 fit• t PAD PE-A FF� ' e PAD=S08. uD a+ G � FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 2421 B sf ADS Builder Name: Lennar Homes 0305 Street: 6670 Paden Wheel Street Permit Office: Pasco A� City,State,Zip: FL, Permit Number: i 9S t�v Owner. Lennar Homes Jurisdiction: 611600 Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(2344.6 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.0 1874.90 ft2 b.Frame-Wood,Adjacent R=11.0 469.69 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (2421.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 2421.00 ft2 6. Conditioned floor area above grade(ft2) 2421 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ftZ 7. Windows(230.7 sqft.) Description Area a.Sup:Attic,Ret:dining rm,AH:laundry 6 484.2 a. U-Factor: Dbl,U=0.54 140.00 ft2 SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.58 64.00 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 34.2 SEER:15.00 c. U-Factor: Dbl,U=0.56 26.67 ft2 SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 32.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 4.283 ft. Area Weighted Average SHGC: 0.309 14.Hot water systems 8. Floor Types (2420.2 sqft.) Insulation Area a.Electric Cap:40 gallons EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 2420.20 ft2 b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.095 Total Proposed Modified Loads: 77.09 PASS Total Baseline Loads: 77.37 I hereby certify that the plans and specifications covered by Review of the plans and O 'SATfi, this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance Dave /JAGh/- with the Florida Energy Code. D AGUl PREPARED BY: Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 hereby certify that this building,as de si ne s in compliance Florida Statutes. ' with the Florida Energy Code. op OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house. 9/27/2017 6:52 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 6 FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method 0305 Project Name: 2421 B sf ADS Builder Name: Lennar Homes Street: 6670 Paden Wheel Street Permit office: Pasco City,State,Zip: FL, Permit Number: Owner: Lennar Homes .jurisdiction: 611600 Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(2344.6 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.0 1874.90 ft2 b.Frame-Wood,Adjacent R=11.0 469.69 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (2421.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 2421.00 ft2 6. Conditioned floor area above grade(ft2) 2421 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(230.7 sqft.) Description Area a.Sup:Attic,Ret:dining rm,AH:laundry 6 484.2 a. U-Factor: Dbl,U=0.54 140.00 ft2 SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.58 64.00 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 34.2 SEER:15.00 c. U-Factor: Dbl,U=0.56 26.67 ft2 SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 32.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 4.283 ft. Area Weighted Average SHGC: 0.309 14.Hot water systems a.Electric Cap:40 gallons 8. Floor Types (2420.2 sqft.) Insulation Area EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 2420.20 ft2 b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.095 Total Proposed Modified Loads: 77.09 PASS Total Baseline Loads: 77.37 I hereby certify that the plans and specifications covered by Review of the plans and THE S1" off: TF this calculation are in compliance with the Florida Energy specifications covered by this = p Code. calculation indicates compliances r;,_' s, �. Dave A/J�C/w with the Florida Energy Code. DVe A PREPARED BY: h Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 I hereby certify that this building,as designed, is in compliance Florida Statutes. with the Florida Energy Code. COZi y`r OWNER/AGENT: BUILDING FILIAL: DATE: DATE: ' 1Ao' - Compliance requires certification by the air handler unit manufacturer that the air hand) enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house. 9/27/2017 6:52 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 6 f FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method 0305 Project Name: 2421 B sf ADS Buif8er Name: Lennar Homes Street: 6670 Paden Wheel Street Permit office: Pasco City,State,Zip: FL, Permit Number: Owner. Lennar Homes Jurisdiction: 611600 Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(2344.6 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.0 1874.90 ft2 b.Frame-Wood,Adjacent R=11.0 469.69 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (2421.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 2421.00 ft2 6. Conditioned floor area above grade(ft2) 2421 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(230.7 sgft.) Description Area a.Sup:Attic,Ret:dining rm,AH:laundry 6 484.2 a. U-Factor. Dbl, U=0.54 140.00 ft2 SHGC: SHGC=0.31 b. U-Factor. Dbl,U=0.58 64.00 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 34.2 SEER:15.00 c. U-Factor: Dbl,U=0.56 26.67 ft2 SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 32.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 4.283 ft. Area Weighted Average SHGC: 0.309 14.Hot water systems 8. Floor Types (2420.2 sqft.) Insulation Area a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 2420.20 ft2 b. Conservation features EF:0.950 b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.095 Total Proposed Modified Loads: 77.09 PASS Total Baseline Loads: 77.37 I hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this b Off„ Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: - Dave AupGh Before construction is completed r . DATE: this building will be inspected forf�Ji ;; compliance with Section 553.908 I herebycertify that this building,as designed,is in compliance Florida Statutes. fY 9� 9 p with the Florida Energy Code. G'O� OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with Section 803 of RESNET Standards, is not greater than 0.030 Qn for whole house. 9/27/2017 6:52 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software _ Page 1 of 6 f ' FORM R405-2014 PROJECT Title: 2421 B sf ADS Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 2421 Lot# Owner: Lennar Homes Total Stories: 1 Block/SubDivision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: Lennar Homes Rotate Angle: 315 Street: Permit Office: Cross Ventilation: No County: Pasco Jurisdiction: Whole House Fan: No City,State,Zip: Family Type: Single-family FL, New/Existing: New(From Plans) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Tampa FL_TAMPA_INTERNATI 2 39 91 70 75 645.5 54 Medium BLOCKS Number Name Area Volume 1 Entire House 2421 22767.3 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 master bdrm 278 2585.4 No 2 1 1 Yes Yes Yes 2 o wic 57 530.1 No 0 1 Yes Yes Yes 3 privy 19 176.7 No 0 1 Yes Yes Yes 4 o bath 122 1134.6 No 0 1 Yes Yes Yes 5 dining rrn 325 3022.5 No 0 1 Yes Yes Yes 6 foyer 49 455.7 No 0 1 Yes Yes Yes 7 living rm 193 1794.9 No 0 1 Yes Yes Yes 8 laundry 77 716.1 No 0 1 Yes Yes Yes 9 bdrm 2 154 1432.2 No 1 1 1 Yes Yes Yes 10 bath 2 47 437.1 No 0 1 Yes Yes Yes 11 bdrm 3 161 1497.3 No 1 1 1 Yes Yes Yes 12 bdrm 4 166 1543.8 No 1 1 1 Yes Yes Yes 13 bath 3 54 502.2 No 0 1 Yes Yes Yes 14 kitchen 126 1423.8 Yes 0 1 Yes Yes Yes 15 nook 200 1860 No 0 1 Yes Yes Yes 16 family rm 393 3654.9 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio master bdrm 41.8 ft 0 278 ftz ___ 0 0 1 2 Slab-On-Grade Edge Insulatio o wic 9.5 ft 0 57 ftz — 0 0 1 9/27/2017 6:52 AM EnergyGauge@ USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 6 r ' FORM R405-2014 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 3 Slab-On-Grade Edge Insulatio privy 3.5 ft 0 18.8 ft2 1 0 0 4 Slab-On-Grade Edge Insulatio o bath loft 0, 122.4 ft2 1 0 0 5 Slab-On-Grade Edge Insulatio dining rm 7 ft 0 324.5 ft2 0 0 1 6 Slab-On-Grade Edge Insulatio foyer 14 ft 0 49 ft2 1 0 0 7 Slab-On-Grade Edge Insulatio living rm 31.5 ft 0 192.9 ft2 0 0 1 8 Slab-On-Grade Edge Insulatio laundry 8 ft 0 77 ft2 1 0 0 9 Slab-On-Grade Edge Insulatio bdrm 2 25 ft 0 154 ft2 __ 0 0 1 10SIab-On-Grade Edge Insulatio bath 2 5.3 ft 0 47.3 ft2 ___ 1 0 0 11Slab-On-Grade Edge Insulatio bdrm 3 14.3 ft 0 160.8 ft2 r 0 0 1 12SIab-On-Grade Edge Insulatio bdrm 4 11.5 ft 0 166.1 ft2 0 0 1 13SIab-On-Grade Edge Insulatio bath 3 15 ft 0 54 ft2 1 0 0 14SIab-On-Grade Edge Insulatio kitchen 1 ft 0 125.6 ft2 __ 1 0 0 15SIab-On-Grade Edge Insulatio nook 19.9 ft 0 199.5 ft2 0 0 1 16SIab-On-Grade Edge Insulatio family rm 9 ft 0 393.3 ft2 0 0 1 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 2708 ft2 0 ft2 Medium 0.85 No 0.9 No 0 26.6 / ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 2421 ft2 N N 9/27/2017 6:52 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 6 r r r FORM R405-2014 CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) master bdrm 30 Blown 278 ft2 0.1 Wood 2 Under Attic(Vented) o wic 30 ;Blown 57 ft2 0.1 Wood 3 Under Attic(Vented) privy 30 Blown 19 ft2 0.1 Wood 4 Under Attic(Vented) o bath 30 Blown 122 ft2 0.1 Wood 5 Under Attic(Vented) dining rm 30 Blown 325 ft2 0.1 Wood 6 Under Attic(Vented) foyer 30 Blown 49 ft2 0.1 Wood 7 Under Attic(Vented) living rm 30 Blown 193 ft2 0.1 Wood 8 Under Attic(Vented) laundry 30 Blown 77 ft2 0.1 Wood 9 Under Attic(Vented) bdrm 2 30 Blown 154 ft2 0.1 Wood 10 Under Attic(Vented) bath 2 30 Blown 47 ft2 0.1 Wood 11 Under Attic(Vented) bdrm 3 30 Blown 161 ft2 0.1 Wood 12 Under Attic(Vented) bdrm 4 30 Blown 166 ft2 0.1 Wood 13 Under Attic(Vented) bath 3 30 Blown 54 ft2 0.1 Wood 14 Under Attic(Vented) kitchen 30 Blown 126 ft2 0.1 Wood 15 Under Attic(Vented) nook 30 Blown 200 ft2 0.1 Wood 16 Under Attic(Vented) family rm 30 Blown 393 ft2 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below R-VPhle Et In Ft In Area P-\Lqllle Fraction Ahsor Grnrle% 1 E=>NE Exterior Concrete Block-Int Insufiaster bdrm 4 14 6 10 0 145.0 ft2 0 0 0.6 0 2 S=>SE Exterior Concrete Block-Int Insurhaster bdrm 4 18 6 10 0 185.0 ft2 0 0 0.6 0 3 W=>SW Exterior Concrete Block-Int Insurbaster bdrm 4 8 9 10 0 87.5 ft2 0 0 0.6 0 4 E=>NE Exterior Concrete Block-Int Insul o wic 4 9 6 9 4 88.7 ft2 0 0 0.6 0 5 E=>NE Exterior Concrete Block-Int Insul privy 4 3 6 9 4 32.7 ft2 0 0 0.6 0 6 E=>NE Exterior Concrete Block-Int Insul o bath 4 10 0 9 4 93.3 ft2 0 0 0.6 0 7 N=>NW Garage Frame-Wood dining rm 11 6 6 11 4 73.7 ft2 0 0.25 0.01 0 8 N=>NW Exterior Concrete Block-Int Insul foyer 4 7 0 9 7 67.1 ft2 0 0 0.6 0 9 W=>SW Garage Frame-Wood foyer 11 6 9 9 7 64.7 ft2 0 0.25 0.01 0 10 N=>NW Exterior Concrete Block-Int Insul living rm 4 15 0 10 0 150.0 ft2 0 0 0.6 0 11 E=>NE Exterior Concrete Block-Int Insul living rm 4 16 6 10 0 165.0 ft2 0 0 0.6 0 12 N=>NW Garage Frame-Wood laundry 11 7 0 9 4 65.3 ft2 0 0.25 0.01 0 _13 E=>NE Garage Frame-Wood laundry 11 1 0 9 4 9.3 ft2 0 0.25 0.01 0 14 N=>NW Garage Frame-Wood bdrm 2 11 27 6 9 4 256.7 ft2 0 0.25 0.01 0 15 W=>SW Exterior Concrete Block-Int Insul bdrm 2 4 11 0 9 4 102.7 ft2 0 0 0.6 0 _16 W=>SW Exterior Concrete Block-Int Insul bath 2 4 5 3 9 4 49.0 ft2 0 0 0.6 0 17 W=>SW Exterior Concrete Block-Int Insul bdrm 3 4 14 3 9 4 133.0 ft2 0 0 0.6 0 18 W=>SW Exterior Concrete Block-Int Insul bdrm 4 4 11 6 9 4 107.3 ft2 0 0 0.6 0 19 S=>SE Exterior Concrete Block-Int Insul bath 3 4 9 0 9 4 84.0 ft2 0 0 0.6 0 _20 W=>SW Exterior Concrete Block-Int Insul bath 3 4 6 0 9 4 56.0 ft2 0 0 0.6 0 _21 E=>NE Exterior Concrete Block-Int Insul nook 4 4 9 11 4 53.8 ft2 0 0 0.6 0 _22 SE=>E Exterior Concrete Block-Int Insul nook 4 5 6 11 4 62.3 ft2 0 0 0.6 0 _23 S=>SE Exterior Concrete Block-Int Insul nook 4 9 9 11 4 110.5 ft2 0 0 0.6 0 _24 S=>SE Exterior Concrete Block-Int Insul family rm 4 9 0 11 4 102.0 ft2 0 0 0.6 0 9/27/2017 6:52 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 6 FORM R405-2014 DOORS # Ornt Door Type Space Storms U-Value Ft In In Ft WidthArea 1 N=>NW Insulated foyer None .2 3 6 8 20 ft2 2 E=>NE Wood nook None .2 2 8 6 8 17.8 ft2 3 N=>NW Wood laundry None .4 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered orientation =>)changed to Worst Case. Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 S=>SE 2 Metal Low-E Double Yes 0.54 0.31 32.0 ft2 1 ft 0 in 1 ft 7 in None None 2 E=>NE 6 Metal Low-E Double Yes 0.54 0.31 12.0 ft2 1 ft 0 in 1 ft 7 in None None 3 N=>NW 8 Metal Low-E Double Yes 0.56 0.28 4.0 ft2 6 ft 0 in 0 ft 4 in None None 4 N=>NW 10 Metal Low-E Double Yes 0.56 0.28 22.7 ft2 6 ft 0 in 0 ft 4 in None None 5 E=>NE 11 Metal Low-E Double Yes 0.54 0.31 16.0 ft2 1 ft 0 in 1 ft 7 in None None 6 W=>SW 15 Metal Low-E Double Yes 0.54 0.31 16.0 ft2 1 ft 0 in 1 ft 7 in None None 7 W=>SW 17 Metal Low-E Double Yes 0.54 0.31 16.0 ft2 1 ft 0 in 1 ft 7 in None None 8 W=>SW 18 Metal Low-E Double Yes 0.54 0.31 16.0 ft2 1 ft 0 in 1 ft 7 in None None 9 SE=>E 22 Metal Low-E Double Yes 0.54 0.31 16.0 ft2 8 ft 0 in 0 ft 4 in None None 10 S=>SE 23 Metal Low-E Double Yes 0.54 0.31 16.0 ft2 1 ft 0 in 1 ft 7 in None None 11 S=>SE 24 Metal Low-E Double Yes 0.58 0.32 64.0 ft2 9 ft 0 in 0 ft 4 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 574 ft2 574 ft2 61.5 ft 9.3 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000418 2656.2 145.82 274.24 .3137 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump Split HSPF:8.5 32.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 15 34.2 kBtu/hr 1026 cfrn 0.85 1 sys#1 9/27/2017 6:52 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 6 FORM R405-2014 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 40 gal ` 70 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS —Supply— —Return— Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 484.2 ft dining rm 121 ft2 Proposed Qn laundry —cfm 72.6 cfm 0.03 0.60 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Coolin Jan Feb Mar A r May X Jun X Jul rj Au Se Oct Nov Dec Heating Jan fXj Feb X�Mar f APr May f Jun Jul AuSep f Oct jNov X Dec Ventin Jan [ ]Feb X Mar [X A r [ Ma [ Jun Jul Aug Se [X Oct [X]Nov [ Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 9/27/2017 6:52 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 6 of 6 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerformance Index, the more efficient the home. FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul, Exterior R=4.0 1874.90 ft2 b.Frame-Wood,Adjacent R=11.0 469.69 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 10.Ceiling Types Insulation Area 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 2421.00 ft2 6. Conditioned floor area(ft2) 2421 b.N/A R= ft2 7. Windows ' Description Area c.N/A R= ft2 a. U-Factor: Dbl,U=0.54 140.00 ft2 11.Ducts R ft2 SHGC: SHGC=0.31 a.Sup:Attic,Ret:dining rm,AH:laundry 6 484.2 b. U-Factor: Dbl,U=0.58 64.00 ft2 SHGC: SHGC=0.32 12.Cooling systems kBtu/hr Efficiency c. U-Factor: Dbl,U=0.56 26.67 ft2 a.Central Unit 34.2 SEER:15.00 SHGC: SHGC=0.28 d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 32.8 HSPF:8.50 Area Weighted Average Overhang Depth: 4.283 ft. Area Weighted Average SHGC: 0.309 8. Floor Types Insulation Area 14.Hot water systems a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 2420.20 ft2 EF:0.95 b.N/A R= ft2 c.N/A R= ft2 b. Conservation features None 15.Credits Pstat certify that this home has complied with the Florida Energy Efficiency Code for Building TAE ST Construction through the above energy saving features which will be installed (or exceeded) 0 A?Ao in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant featu es. Builder Signature: Date: 10/10/17 _ . . Address of New Home: 6670 Pad n Wheel Street City/FL Zip: Ze h rhills,p y FL 33541 *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 9/27/2017 6:53 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 BuildingAnalysis Job: 2421E sf ADS Y Date: 9/2712017 Entire House By: Dave Aldrich Bayonet Plumbing Heating and Cooling 8950 New York Ave,Hudson Project • • For: Lennar Homes Design Conditions Location: Indoor: Heating Cooling Tampa International AP, FL, US Indoor temperature(OF) 70 75 Elevation: 10 ft Design TD (°F) 39 16 Latitude: 28°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 34.7 54.7 Dry bulb(°F) 31 91 Infiltration: Daily range(OF) - 14 ( L ) Method Simplified Wet bulb(OF) - 77 Construction quality Semi-tight Wind speed (mph) 15.0 7.5 Fireplaces 0 • Component Btuh/ft2 Btuh % of load Walls 5.6 9016 26.0 ucts Glazing 30.2 6822 19.7 Wall Doors 23.5 867 2.5 nfiltrafion Ceilings 1.3 3037 8.8 Floors 3.0 7334 21.2 Infiltration 2.1 3943 11.4 Ducts 3596 10.4 Piping 0 O Glazing Floors Humidification 0 0 Ventilation 0 0 Doors Ceilings Adjustments 0 Total 34613 100.0 Component Btuh/ft2 Btuh % of load Walls 2.8 4485 16.4 Wall Internal Gains Glazing 41.7 9434 34.4 Doors 18.4 679 2.5 Ceilings 1.7 4199 15.3 Floors 0 0 0 Ducts Infiltration 0.4 820 3.0 Ducts 4032 14.7 Ventilation 0 0 Infiltration Internal gains 3750 13.7 Glazing Blower 0 0 Adjustments 0 Ceilings Total 27399 100.0 Doors Latent Cooling Load= 3433 Btuh Overall U-value= 0.103 Btuh/ft2-°F Data entries checked. Wrl htSOft' 2017-Sep-27 07:12:03 Am9 Right-Sufte®Universal 2017 17.0.23 RSU05714 Page 1 ...th CBA27UHE AH's\2421 sf ADS template 3 ton.rup Calc=MJ8 Front Door faces:NW Pro ect Summa Job: 21 sf ADS 1 � 91 Date: 2712017 Entire House By: Dave Aldrich Bayonet Plumbing Heating and Cooling 8950 New York Ave,Hudson Project • • For: Lennar Homes Notes: Design Information Weather: Tampa International AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 31 OF Outside db 91 OF Inside db 70 OF Inside db 75 OF Design TD 39 OF Design TD 16 OF Daily range L Relative humidity 50 % Moisture difference 55 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 31017 Btuh Structure 23367 Btuh Ducts 3596 Btuh Ducts 4032 Btuh Central vent (0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh none Humidification 0 Btuh Blower e) 0 Btuh Piping 0 Btuh Equipment load 34613 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 27399 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 2700 Btuh Ducts 732 Btuh Central vent (0 cfm) 0 Btuh Heating Coolingg (none) Area(ft2) 2429 2421 Equipment latent load 3433 Btuh Volume(ft') 24945 24945 Air changes/hour 0.22 0.11 Equipment Total Load (Sen+Lat) 30832 Btuh Equiv.AVF(cfm) 91 46 Req. total capacity at 0.85 SHR 2.7 ton Heating Equipment Summary Cooling Equipment Summary Make Lennox Make Lennox Trade 14HPX SERIES Trade 14HPX SERIES Model 14HPX-036-230-21 Cond 14HPX-036-230-21 AHRI ref 10258589 Coil CBA27UHE-036-230*++TDR AHRI ref 10258589 Efficiency 8.5 HSPF Efficiency 12.5 EER, 15 SEER Heating input Sensible cooling 29580 Btuh Heating output 32800 Btuh @ 47°F Latent cooling 5220 Btuh Temperature rise 25 OF Total cooling 34800 Btuh Actual air flow 1200 cfm Actual air flow 1200 cfm Air flow factor 0.035 cfm/Btuh Air flow factor 0.044 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.89 Capacity balance point= 33 OF Backup: n/a n/a Input= 0 kW, Output= 0 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. ^.` � wrightsoft12 m Right-Suite®Universal 2017 17.0.23 RSU05714 2017-Sep 27 07:Page age 1 1 ACCK ...th CBA27UHE AH's\2421 sf ADS template 3 ton.rup Calc=MJ8 Front Door faces:NW Manual S Compliance Report Job: 2421B sf ADS p Date: 9/2712017 Entire House By: Dave Aldrich Bayonet Plumbing Heating and Cooling 8950 New York Ave,Hudson Project • • For: Lennar Homes Cooling Equipment Design Conditions Outdoor design DB: 91.3°F Sensible gain: 27399 Btuh Entering coil DB: 75.7°F Outdoor design WB: 77.3°F Latent gain: 3433 Btuh Entering coil WB: 62.8°F Indoor design DB: 75.0°F Total gain: 30832 Btuh Indoor RH: 50% Estimated airflow: 1200 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: SpIitASHP Manufacturer: Lennox Model: 14HPX-036-230-21+CBA27UHE-036-230*++TDR Actual airflow: 1200 cfm Sensible capacity: 29070 Btuh 106% of load Latent capacity: 5130 Btuh 149% of load Total capacity: 34200 Btuh 111% of load SHR: 85% Heating Equipment Design Conditions Outdoor design DB: 30.8°F Heat loss: 34613 Btuh Entering coil DB: 69.6°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: SpIitASHP Manufacturer: Lennox Model: 14HPX-036-230-21+CBA27UHE-036-230*++TDR Actual airflow: 1200 cfm Output capacity: 32800 Btuh 95% of load Capacity balance: 33 OF Supplemental heat required: 1813 Btuh Economic balance: -99 OF Backup equipment type: Elec strip Manufacturer: n/a Model: n/a+n/a Actual airflow: 1200 cfm Output capacity: 0 kW 0% of load Temp. rise: 0 OF Meets are all requirements of ACCA Manual S. wri htSOft9 2017-Sep 27 07:age 1 9 Right-Suite•1 Universal 2017 17.0.23 RSU05714 Page 1 ACCK ...th CBA27UHE AH's\2421 sf ADS template 3 ton.rup Calc=MJ8 Front Door faces:NW PASCO COUNTY, FLORIDA Permit No. Date Permitted Z l -Builder Name/Owner Name �&C Control#' —: County Parcei No, 05- -2(•t '170•i d006-0052i nbDht: Address/Location Q 0 Ader, u e ST` Ciassiftcatiot�l*i of Use 1 c �>d t ` TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: Exempt p Yes []No How Determined Impact Fee Amount $. 31632, 00 Zone No. 'TAZ: U : SCHOOL IMPACT FEE Account (056) Single-Family.Detached House Amount $ 6?to (05,) Mobile Horde (058) Other'Residetltiat 123) Collection Fee Exempt [ Yes 5 No How Determined PARKS AND RECREATION FEE Land Account Land-Credit Land Total Recreatlon:Account Recreation Credit Recreation Total Zone TOTAL AMOUNT $ Exempt ❑Yes ❑No How Determined LIBRARY FEE Land Account Land Credit Land Total Facility Account Facility Credit Facility Total Exempt ❑Yes ❑No How Determined Total A=966i ?`'''� 1, RESOURCE FEE ERU TOTAL AMOUNT Prepared Byn, Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE . BEEN PAID AND RECEIPTED FOR BY A CENTRAL.PERMITTING OFFICEOF P.ASCO COUNTY Acknowledgement below does not imply ecosplance•oftoncurrence,but simply receipt of a copy+-of this fort,placing the building permit owner on notice of=this•assessment and the conditions of payment for same. DATE RECEIVED BY RECEIPT NO. " DATE BY i Building and Construction Services(BCS) PAS C i COUNTY FLORIDA Blower Door. 'rest Report Form i (.�I'i:N`h.1("i�ti-l�!•'llF,i:V f')ri ACi;\. Proprrly Address: TTeistting Company Name: ' � Permit N: � J17� � , Test Date: g� Tester Name: r iTester Cen it: y� Contact Phone: I Email: i I _ i402.4.1.2 Testing.Building envelope air tightness shall be demonstrated by Section 402.4.1.2 i The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour. Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).As required by the Building Official,testing shall be conducted by an approved third party.A written report of the results of the test shall be signed by the party conducting the test(including Agency Name)and provided to the Building Official prior i to Certificate of Occupancy issuance: Testing shall be performcd at any time after creation of all scheduled penetrations of the building thermal envelope. During testing:(check to verify condition met) >�Exterior windows and doors, fireplace and stove doors shall be closed, but.not sealed, beyond the intended weather-stripping or other i VJ Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond ; V intended infiltration ,(Interior doors,if installed at the time of the test,shall be open I 1�Exterior doors for'continuous ventilation systems and heat recovery ventilators shall be closed and sealed i VVHeating and cooling systems,if installed at the time of the test,shall be turned off �Z1 supply and return'registers,if installed at the time of the test,shall be fully open 9 I Vb Building volume(ft') = oC Q50 Airflow at 50 Pascal(CFM) _ ACH5o Air changes per hour at 50 Pascal e Q50x 60-Vb= oC. ACHso(3.19ACHminimum) Pass I� Fail ❑ ❑Outside Air mechanically introduced to space(less than 3.0 ACID I hereby certify Marthe above envelope leakage performance results demonstrate compliance with Florid finery Code requirements in accordance with SectionR4/022.4.1.2, SignatufcofT,ester bite f . r 1 Jet Stream° Ultra Blowing Wool Insulation NA mo Attic and Cavity Wall Card ib lime.h mye,eAerj Batts and Blankets Equipment Required When installed in accordance with the manufacturer's It is recommended that a pneumatic blowing machine and a corrugated hose with a minimum%<"internal corrugation,a minimum length recommendations,Knauf Insulation baits and blankets will of 150'.Coils in the hose should not be less than 36"in diameter.Acceptable material feed rate is 5-35 lbs/minute.Recommended feed provide the full R-value. rate is 15-25 lbs/minute. R-Value* Minimum Thickness Thermal Performance(Sidewall and Attic Application) To obtain an The stated thermal resistance(R-value)is provided by installing in accordance with the manufacturer's instructions.Failure to install the insulation resistance Installed insulation should required number of bags per 1,000 square feet and exceeding the maximum square feet of coverage per bag as recommended by the label (R-Value)of: not be less than: will result in lower installed R-values.Field blending of this product with other loose fill insulations is not recommended by the manufacturer. R-49 13.75" Cavity Wall Bag Net Weight-Nominal 32 lbs.,Minimum 31 lbs. R-38HD 10.25" R-38 12.00" R-Value* Bags per 1000 SF Maximum Net Minimum R 30HD 8.25" To obtain an The number of bags Coverage per Bag Weight per SF insulation per 1,000 square feet Contents of this The weight per square R-30 10.00" Cavity resistance of net area should not bag should not feet of installed insulation R-26" 9.00" Framing Depth of: Density be less than: cover more than: should not be less than: R-22 6.50" 2"x 4" 3.50" R-15 1.8 lbs./cu.ft. 16.4 bags 61.0 sq.ft. 0.525 lbs. R-21HD 5.50" 2"x 6" 5.50" R-23 1.8 lbs./cu.ft. 25.8 bags 38.8 sq.ft. 0.825 Its. R-19 6.25"** R-15HD 3.50" 2"x 8" 7.25" R-31 1.8 lbs./cu.ft. 34.0 bags 29.4 sq.ft. 1.088 lbs. R-13 3.50" 2"x 10" 9.25" R-39 1.8 lbs./cu.ft. 43.4 bags 23.1 sq.ft. 1.388 lbs. R-11 3.50" R means resistance to heat flow.The higher the R-value,the greater the insulating power.To get the marked R-value,it is essential that this insulation be installed properly. ".50 R-8 2 R-16ina5 -cavty.ConformstoASTMC6 .50 ederal Open Attic Application Bag Net Weight-Nominal 32lbs.,Minimum 31 lbs. Specification HH-1-521 F. Minimum Bags/ Maximum Minimum Initial Settled Framing Adjustment 1,000 SF Coverage Weight Installed Thickness** To compensate for taming members,the number of bags per The number of bags/ Contents of this The weight/SF Thickness Contents of this 1,000 sq.ft.of area to be insulated should be as shown below. R-Value* 1,000 SF of net area bag should not of installed Installed insulation bag should Ba s/MSF Ba s/MSF To obtain an insulation should not be less cover insulation should not should not be less not cover more 9 9 resistance(R-Value)of: than: more than: be lessthan than: than: Joist 16"O.C. 24"O.C. R-60 29.7 33.6 SF .952 lbs. 19.750" 19.750" R-Value Dimensions Framing Framing 2x4 29.2 29.4 R-49 23.5 42.5 SF .753 lbs. 16.375" 16.375" R-60 2x6 28.9 29.1 R-44 20.9 47.8 SF .670 Its. 14.875" 14.875" 2x8 28.6 28.9 R-38 17.8 56.2 SF .569 Its. 13.000" 13.000" 2x4 23.0 23.2 R-30 13.6 73.3 SF .437 lbs. 10.375" 10.375" R-49 2x6 22.7 22.9 R-26 11.8 85.0 SF .377 lbs. 9.125" 9.125" 2x8 22.4 22.7 R-22 9.8 102.2 SF .313 lbs. 7.750" 7.750" 2x4 20.4 20.6 R-44 2x6 20.1 20.3 R-19 8.4 119.3 SF .268 Its. 6.750" 6.750" 2x8 19.8 20.1 ��R-11 13 5.7 175.3 SF .183 lbs. 4.750" 4.750" 2x4 17.3 17.4 1 4.7 1 210.8 SF .152 lbs. 4.000" 4.000" R-38 2x6 17.0 17.2 Bag Net WeightNominal321bs.,Minimum 31 Ibs. 2x8 16.7 17.0 Coverage and installation data were determined using a Volu-Malice II blowing machine in third gear with 13'gate opening,2.0 psi au pressure and 150'of 3'intemalymnugated hose. This product omfomns to the performance requirements ofASTM C 764,Type I,and cancelled Federal specification HH4-1030B,Type I,pass B.R-values are determined in accordance with C 687 and C 518. 2x4 13.2 13.3 "W means resistance to heat flow.The higher the R-value,the greater the insulating power.To get the marked R-value,it is essential that this insulation be installed properly..If you do it yourself,gel inst - R-30 2x6 12.9 13.1 bons and follow them carefully.Instructions do not come with this package. "Based on Third Party 2-year settling study,the predicted settlement over a 20-year period would be 1 percent or less.This amount of settling is thermally insignificant.Therefore,the installed and settled 2x8 12.6 12.9 thicknesses are effectively the same. 2x4 11.3 11.4 Volu-Maticsll is a registered trademark of Unisul. R-26 2x6 11.0 11.2 Builder's Insulation Statement 2x8 10.8 11.0 Jet Stream Ultra has been installed in conformance with the included recommendations to provide a thermal resistance of... 2x4 9.3 9.5 R-Value Thickness R-22 2x6 9.1 9.3 Attic Area R- at Inches 2x8 1 8.8 9.1 Sloped Ceilings R- at Inches 2x4 7.9 8.1 Walls R- at Inches R-19 2x6 7.7 7.9 2x8 7.4 7.7 Floors(over an unheated crawl space) R- at Inches 2x4 5.3 5.4 Crawl Space Perimeter R- at Inches R-13 2x6 5.0 5.2 Date Installed 2x8 4.8 5.0 Blo istjation has been if tat in conformance with the above re e onsA provide an R-value of: 2x4 4.3 4.4 R- using o� bags of this insulation to cover, square feet of area R-11 2x6 4.1 4.3 at a minimum thickness of ( inches. 2x8 3.8 4.1 Uk E Insulation Contractor(signature GREEENGUANGUA RD Gold"' Knauf Insulation buildirg insulation achieved Company ry jn D e UL Envi--,GREENGUARD Gold and N UL Emnanment validated to be formaldehyde free (12 te ULEnvrronmenr GREENGUARD Home Builder(signature) 0 CertincaKon V"grvms- Products are-ii8ed ro Ul Environment GREENGUARD smndords blow ch"micvl Company Date into indoor ois during produ0 woo.. Formoresinformmion,visit ul wm/99. The coverage information on this Attic/Sidewall card applies to the entire United States(including Minnesota). www.knaufinsulation.us Knauf Insulation,Inc. One Knauf Drive,Shelbyville,IN 46176 Tel:(800)825-4434 ext.8300 FAX:(317)398-3675 ©2015 Knauf Insulation,Inc. 5335 - 8TH STREET (813)780-0020 CERTIFICATE OF'OCCUPANCY Address: 6670 PADEN WHEEL ST Owner: LENNAR HOMES LLC ZEPHYRHILLS, FL. 4600 W CYPRESS ST STE 200 Subdiv: SILVERADO TAMPA FL 33607-4099 Parcel: 05-26-21-0070-00300-0050 Work Type: 101-NEW CONST/SFR Construction Type: NOT APPLICABLE ❑ Sprinklers Use Classification: NOT APPLICABLE Permit Number: 19508 Date: 7/12/2018 �c Apx� ISS D BY: BUILDI OFFICIAL : WATER MUST BE CHANGED OVER WITHIN 10 DAYS OF ISSUANCE GARBAGE DEPOSIT MUST BE APPLIED FOR PRIOR TO ISSUANCE