Loading...
HomeMy WebLinkAbout18-19509 CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 19509 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL PERMIT INFORMATION = = LOCATION INFORMATION Permit#:19509 Issued: 4/02/2018 Address: 6614 WAGON TRAIL ST Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Lot(s):-.. Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 343,131.90 Total Fees: 14,797.91 Subdivision: SILVERADO Amount Paid: 14,797.91 Date Paid: 4/03/2018 Parcel Number: 05-26-21-0080-00600-0070 CONTRACTOR INFORMATION OWNER INFORMATION Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC Addr: 4600 W. CYPRESS ST STE 200 Address: 4600 W CYPRESS ST STE 200 TAMPA, FL. 33607 TAMPA FL 33607-4099 Phone: (813)574-5743 Lic: Phone: Work Desc: CONSTRUCT SINGLE FAMILY 3,046 SQ FT APPLICATION FEES BUILDING FEE 1,870.20 ELECTRICAL FEE 396.00 PLUMBING FEE 264.00 MECHANICAL FEE 184.80 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE-sfr/100% 4,828.00 SCHOOL IMPACT FEE-sfr/1% 48.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32 SCHOOL-SFR NEW 2% 45.04 SCHOOL IMPACT FEE NEW 2,206.68 0 G Inspections Required FOOTER 2ND ROUGH PLUMB Misc INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans, Specifications and Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. t &-- bm�* C T CTORS SIGNATURE PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIOlf CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER 2018053288 Rcpt:1944465 IRec: 0.00 DS: 0.00 04/02/2018 K. A. , DptY Clerk PRULR S.o'NEIL,Ph.D.PASCO CLERK & COMPTROLLEn - 04 0R BK 18 09:35am PG Of I 9701 -- - -- - Permit No. Parcel ID No 05-26-21-0080-00600-0070 NOTICE OF COMMENCEMENT State of Florida County of Pasco THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 713,Florida Statutes, the following information is provided in this Notice of Commencement: 1. Description of Property: Legal SILVERADO RANCH SUBDIVISION PHASES 6,8&9A PB 75 PG 75 BLOCK 06 LOT 07 Street Address: 6614 Wagon Trail Street Zephryhills FL 33541 2. General Description of Improvement Single Family Residence/Pool/Screen Enclosure/Fence 3. Owner Information: Lennar Homes, LLC. Name 4600 W Cypress St. Ste 200 Tampa FL. 33607 Address City State Interest in Property: Name of Fee Simple Titleholder: N/A (If other than owner) Address City State 4. Contractor: Lennar Homes, LLC Name 4600 W Cypress St, Ste 200 Tampa FL, 33607 Address City State Contractor's Telephone No.: 813.574.5700 5. Surety: N/A Name Address City State Amount of Bond: $ Telephone No.: 6. Lender: N/A Name Address City State Lender's Telephone No.: '7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)(7),Florida Statutes: Lennar Homes, LLC Name 4600 W Cypress St, Ste 200 Tampa FL, 33607 Address City State Telephone Number of Designated Person: 813.574.5700 8. In addition to himself,the owner designates N/A of . to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statutes. Telephone Number of Person or Entity Designated by Owner: 9. Expiration date of Notice of Commencement is one year from the date of recording unless a different date is specified: WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713,. PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. STATE OF FLORIDA COUNTY OF PINELLAS Signature of Owner or Owner's Authorized Officer/Director/Partner/Manager Vice President Signatory's Title/Office The foregoing instrument was acknowledged before me this 30 day of March ,by Steve Robert Smith as Vice President (type of authority ., ice, tee,attorney in fact)for Lennar Homes LLC (name of pa y on behalf h iam nstrument was executed). Personally.Known It OR.Produced Identification❑ Not Signature Type of.ldentification Produced Name(Print) Elissa olleran Verification pursuant to Section 92.525; Florida'Statutes.:Under penalties of perjury,I declare that I have read the foregoing and that the facts stated in it are true'to thi6 best of my knowledge and belief. ELISSAM.HOLLERAN Signature of Natural Person Signing Above • t;. �;�;Gmmhalon�k FF 88583I ',=Ex0ire3 June 0;2020 wpdata/bcs/bcsformt, „� •' sondoOThru7royFolnln+unncet00,7p5lOtp STATE 0F FLORIDA,COUNTY OF PASCO THIS IS T0.CERTIOTHAT THE FOREGOING_IS A . TRUE AND,CORRECT COPY OF THE DOCUMENT ON FILE OR OF PUBLIC RECORD IN THIS OFFICE In E ar t WITNESS MY HAND AND FF1CIA4<SEAL THI • :"a' w DAY OF 4 p �a "'O'NEII,CL COMPTROLLER DEPUTY CLERK 6Y ----- o KO City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: f � Date Received: 7 1N L: :.� s�r�� - Site: -- (0 W t57 Permit Type: /P ", 3 � Approved w/no comments:❑ Approved w/the below comments: Denied w/the below comments: ❑ This comm nth et hall be kept with the permit and/or plans. Q �I 1 i' C� OJ I I A,1--, cJ J` �✓ Kalvin Switzer Irlans Examiner Date Contractor and/or Homeowner (Required when comments are present) Lennar Homes-6614 Wagon Trail St-3,046 sq ft -NEW FEES Column ts SQ. FEET PRICE MAIN OR LIVING: $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ - FEE SHEET ADDRESS DRIVEWAY BUILDING: $ - ELECTRICAL: $ - PLUMBING: $ - MECHANICAL: $ - SUB-TOTAL $ - TOTAL SEWER: n/a WATER: n/a IRRIGATION: $ - TOTAL: $ - WATER METER: n/a IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE FIRE 5% $ - TOTAL: SUB-TOTAL $ - PARK IMPACT FEES SIF'S: $ 2,251.72 100.0% $ 2,206.68 1.0% $ 45.04 TOTAL: $ 2,251.72 balance owe TIF'S: 99% $ - 1% $ - TOTAL: $ 2,251.72 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received Phone Contact for Permitting 813 363 _ 2891 1 1 1 1 1 1 1 1 1 1 1 1 1 Owner's Name Lennar Homes,LLC Owner Phone Number 813,574,5700 Owner's Address 1 4600 W.Cypress St.Ste.200,Tampa,FL 33607 Owner Phone Number Fee Simple Titleholder Name I N/A Owner Phone Number Fee Simple Titleholder Address N/A JOB ADDRESS 6614 Wagon Trail Street LOT# 0070 SUBDIVISION Silverado Ranch Subdivision Ph 2,3,&4 PARCEL ID# 05-26-21-0080-00600-0070 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED II./ II NEW CONSTR e ADD/ALT SIGN Q Q DEMOLISH P INSTALL REPAIR PROPOSED USE SFR 0 COMM = OTHER TYPE OF CONSTRUCTION BLOCK Q FRAME = STEEL = DESCRIPTION OF WORK Single Family Residence/Pool/Screen Enclosure/Fence BUILDING SIZE I U/R SF 3046 SQ FOOTAGE 2584 HEIGHT 2 Story BUILDING $ rl j O VALUATION OF TOTAL CONSTRUCTION ELECTRICAL $ Q` ® PROGRESSENERGY Q W.R.E.C. �• � AMP SERVICE PLUMBING $ MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION 6 � =GAS F-471 ROOFING = SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA I=YES Do BUILDERF COMPANY Lennar Homes,LLC SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address 4600 W.Cypress St.Ste.200, ampa,FL 33607 License# I CGC1518166 ELECTRICIAN COMPANY Edmonson Electric, Inc. SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address 1034 Skipper Road, Tampa, FL 33613 License# EC13005408 PLUMBER COMPANY Bayonet Plumbing, Heating &AC, Inc SIGNATURE REGISTERED Y/ N FEE CURREN Address P.O. Box 5308, Bayonet, FL 674-5308 License# CFC042998 MECHANICAL ACOMPANY Bayonet Plumbing, Heating &AC, Inc SIGNATURE I REGISTERED Y/ N FEE CURREN Y/N Address P.O. Box 5308, Bayonet, FL 3 674-5308 License# I CAC058062 OTHER COMPANY SIGNATURE REGISTERED =1Y/ N FEE CURREN Y/N Address 4211 Shoal Line Blvd, Spring All, FL 34607 License# 1 CCC057991 1111. 1111111111111111 '11111111111111111111111111111111111111111111111 RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. . . Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500) ** Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to "deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that I, the applicant, have been provided with a copy,of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner" prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior-to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone W" unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE6OF COMMENCEMENT. FLORIDA JURAT(F.S. 117.03) OWNER OR AGENT A CONTRACTOR Subscribed and sworn to(or affirmed)bef a me this Subscribed and sworn to(or afrir ed)before me this JU-Jan-1 a by Paul Sweene 30Jan-Jan by Paul Sween Who is/are personally known to me or has/have predUsed Who is/are personally known to Oe or as identification. as identification. Notary Public Notary Public Commission No. FF98537 Commission No. FF98537 Elissa M.Holleran Elissa M.Holleran Name of Notary tvoed,printed or stamped- Name of Notary typed,printed or stamped �tl��k b►.�I pl��1A�!'I �+rr7an����u6ae4T � yl�R�ft'kJ:�9n11d.�l�QE,9Bp�'- �'s_5��1�1�11Pal�y��� ��k1�IJYIP�9��i��d I ®nhd��YrJ7�F�otvit�ocflkt�ll��lpl1 SKETCH ONLY SEC._05 TWP. 26 S, RNG. 21 E. PLOT PLAN NOT A BOUNDARY SURVEY BEARING BASIS: LOT 7, BLOCK 6 SILVERADO RANCH SUBDIVISION PHASES 6, 8 & 9A EAST BOUNDARY OF SUBJECT PLAT BEING N 02*35'32" E PASCO COUNTY, FLORIDA. THIS SURVEY IS SUBJECT TO ANY FACTS THAT S N MAY BE DISCLOSED BY A FULL AND ACCURATE PRELIMINARY DRAWING: ON LOT AREA CALCULATION TITLE SEARCH, ALSO SUBJECT TO SETBACKS, THIS PLAN IS FOR PERMITTING PURPOSES LOT = 6059.00 SQ. FT. EASEMENTS AND RESTRICTIONS OF RECORD. ONLY, NOT FOR CONSTRUCTION. VERIFY LIVING AREA = 1093 SQ. FT. = 35 Q. FT. UNDERGROUND FOOTER STEM WALL, AND ALL DIMENSIONS BEFORE ANY CONSTRUCTION. ENTRY SQ. I GARAGE =_4Z7 SO. FT. II UNDERGROUND UTILITIES ARE NOT LOCATED OR LEGEND: COVERED LANAI =__V_ASQ. FT. SHOWN. PROPOSED DRAINAGE FLOW PATIO = 23 SQ. FT.DRIVE CONC. DO NOT SCALE THIS PRINT. DIMENSIONS AND (00.00) PROPOSED GRADE = 440 Q. FT. NOTES TAKE PREFERENCE. A/C & CONC PAD = 18 —SQ. FT. < E-00.00 EXISTING GRADE 0 PRIVATE SIDEWALK = 31 SQ. FT. Ul DESCRIPTION NOT CONTAINING PLAT BOOK AND IMPERVIOUS =_34 7 PAGE INDICATES THAT PLAT IS IN NOTES: =_ 2067 SQ..FT. + PRELIMINARY STAGE AND IS SUBJECT TO- LOT GRADING TYPE = B SOD = 3983—SQ. FT. CHANGE AND/OR REVISION. PROPOSED PAD ELEVATION = 113.2' FRONT SETBACK = 20' OFF LOT AREA CALCULATIONS CERTAIN DATA SHOWN HEREON BASED ON SIDE SETBACK = 75 RIGHT OF WAY =__%9O.OQ_SQ. FT. ENGINEERING PLANS PROVIDED BY CLIENT. REAR SETBACK = 15' DRIVE APRON =-233 SO. FT. PUBLIC SIDEWALK =_275SQ. FT- 10' UTILITY EASEMENT SOD =_A�EL2_SQ. FT. TOTALS AREA =__.jQt0_.(L0_SQ. Fr. DRIVEWAY = A7_2L_SQ. FT. SIDEWALK = 30 LE SO. FT. SOD = !Lf�5�_SQ. FT. LOT 6 BLOCK 6 10 X.00, i Ld S 872428" E ' ' llo.()O, ry b: 0 0. ........ ......... ....... ,a Lri 4V-0" 0 < L() -) I : ...... I .... L0 2�5o' < LLj' 2 L'j (o V)U')MR r, 0 C14 0 0<LUO t TRACT A C14 DRAINAGE AREA Q_ LJ Of < pe) > r Lo 0 .1 1-4 ............. 0 :b 0,00 N 87*24's. zd W < -- 110.00, 0 '•T LOT 8 BLOCK 6 ti 1�6 M X PC(P) PROPOSED: z LOWEST FLOOR ELEVATIONS: o LIVING AREA: 113.90' o GARAGE AREA: DESCRIPTION: ELEVATIONS REFERENCED TO LOT 7 BLOCK 6, MAP OR PLAT ENTITLED "SILVERADO RANCH SUBDIVISION PHASES NORTH AMERICAN VERTICAL 9 6, 8 & 9A", AS RECORDED IN PLAT BOOK 075, PAGES 075 THROUGH 080, OF THE DATUM OF 1988. MEAN SEA PUBLIC 13 UBUC RECORDS OF PASCO COUNTY, FLORIDA. LEVEL= 00.00 FT. I 0 Co. APPARENT APPARENT FLOOD HAZARD ZONE: "X" COMMUNITY PANEL NO. 120230 0455 D EFFECTIVE DATE: 09/30/1992 LOT (C)= CALCULATED I o (C)= CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, rk= CENTERLINE, A/C= AIR CONDITIONER, /C= BACK OF CURB, C/S= vE 'T=CONCRETE SLAB, CH= CHORD, CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= COVERED, E/P= EDGEIOF'F:rA MENT. ESM EASEMENT, F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE. FIR= FOUND IRON ROD, FN&D= FOUNDL-NAIL'-& DISK,-FPP= FOUND PINCHED PIPE, LFE= LOWEST FLOOR ELEVATION, MAS.= MASONRY, OR= OFFICIAL RECORD BOOK, PB= PLAT BOOK, PCP= PERMANENT-CONTROL FOIN<-eRM= PERMANENT z < REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & CAP No. 4493, SN&D= SET NAIL 86)ISK,-_-T6M_-_--�TEIOORARY BENCHMARK, cc U/P= UTILITY POLE, W/F= WOOD FENCE, (R) = RADIAL < 0 Drawn By. Square Feet: 606 OHN R.BEACH&ASSOCIATES,INC. sms 0,09-1 LZMAR`HOMES a i Cr - - . - Lo SURVEYORS AND MAPPERS Checked By. t 911 WEST ST. PETERSBURG DRIVE JRB 05 ONE OLDSMAR, FLORIDA 34677 WAY (813) 854-1276 FAX (813) 855-8370 Scale: 1`30' Date of Survey. NOT VALID WITHOUT THE SIGNATURE AND :6 THE ORIGINAL RAISED SEAL. OF PIFLORIDA olfiofil- oas HN"IRQBEACH ATE e 61— 0 U LICENSED SURVEYOR AND MAPPER FLORIDA LANDLAND SURVEYOR No. 2984 04493 Revisions: 'UTONY ,'' F=124 10 r-' JT !' r' h(\•• if 5 I ��` 12 LOT 46 �. §T FT TYPE A 21 >,e,2o.o3 ,=`cli ,. E;F� 3�� O FF=122,2A` �- xL 45 ''LOT 4,4 ; 124 15' �S'PE A PERT SUxffjE !`�` PAD=122.2 ' PAD=1+Z1.5 ANGf DRAINAGE,-EASME '' E = TY ; •s Ix 121.87 .5,34 f YP ; x 123.83 x 1,�3.27 ' h i t x 123,3,8 t x 124,E / r 113.6 FF=114 20 , 'F=418.26 F t LOT + PA=�1�7.5 r PAD-4'17.5 , i ,FF=118:9 = TYPE A TY�`fE. A r r t ,+ t3.02 LOT ,40 PAD=118'2 ` , 'E p ES TYPE,( Q - r tl LOT 39,r + • , r i PAD=119:6 dro TYPE'`Aro i 117 i r o t I< < FF=1�0 30 '� t - r LOT; 38 1 I �r�' FF:Z�117.60. ; PADS 119.E ; t ,, „6.6 •u` r'LOT 3 +^ryj*,ry�a� +� o TYPE A;+ '' ! r i ,'�'Ap=116, ,' t ! 49 TYPE B ' F �• 9 P, FF 'I 18 70 ,+'LOT 3 " r I ,A, PAD-1.18.0 i . t L03 ! I / , ''c�• `� , TWE A ,-'' t i PAD=114.1 r co TYPE' 8 , r + / , '- r`PF=116.30 I ' r' LOT 36 I,' ` FF= r PAD=115.6 `Y t ,' t LOT" TYPE A , ,,1 r PAD-1,15.1 , t 03 r-` ff TYPE 8 , FF'—1 15.30 I � „s. Lo. I LOT 35 F`F=114.80� PAD=114.E LOT 5 .1 ,TYPE A �t r t PAD=11'4.T, +` / $. X„4,,, fis?, , �. ,' TYPE' 8 1 cn r F.F=114.40 ` 1149 LOT6 31 � , t ,� �• + _ +FF 1=1;3.. ,I -TYPE ti-1 PAP ', AVE c 1.�, ^ F .h TY±PIt ,.B lt7 X. - ?r5'I FF=1'13.60 i DD LOT 33 ,+ ,J`I �113.10 th N ,}` +''. , ' z( 8 FApP1A9 LOT 92.4 TYPE a +�• -,y " t?AD 1 -}- TYPE 8 i o a u-� I i • i , ing e Fam' Y Dwell*rig Plan Review Comments 1. F.F:E. shall lie;a mnimum:of 8" above the road elevation;and an engineered site plan. . 2.. .'Lots shall be graded to comply with R40 IJ of the F.R.C. .. 3. ,Compaction:test required if 24"'or more:of ,fill dirt is.brought in at any one place: 4: Tie insurvey-required before pouring concrete.. 5.: _Driveways require a R.O.W. use permit:: All 4 sides of driveway.thru the sidewalk shall'have .' expansion material: .. '6. All setbacks.shall be met.: 7.: All.property:markers-shall be,uncovered and marked.at time of first 'inspection: .8:. All A.D.A.requirements shall be met.: - - 9.. No:electric;plumbing,mechanical;.or framing shall be covered without an inspection and approval first. . l 0. All Garages shall,comply mith section R302:6 of the:F.B.C.:(Fire-Separation). J 11:A liances:shall not:be installed in-a location where sub"ectto mechanical damage unless. pp protected:by approved barriers: M303.4 of.'the F.B.0 .12. Water heaters shallcomply with section:P607.3 of the F.B.C. 13. Foundatiori'supports for.-A/C.units shaff-be raised at least 3" above finished grade,. M1308.1 :. 14.Return air in all_:bedrooms.F.B.C. _M.1620.4 15. Smoke detectors are to b-c installed in'accordance:with R31:3.1-of the:F.B.C. 16:All glazing requirements are:to be'in accordance with R308.4.of the F.B:C. 17. All means_of egress are"to be in-a"cordahee with R31 L:of the F.B.C. 18. `.`Green gypsum board"shall riot be used:as-a backer.irishowers or tubs. R702.462.F.B.C. . . 19. Combination-type AFCI breakers are,required-at all,locations requiring an AFCI.type breaker. 20: Carbon monoxide alarms will.be required in hbw:construction,that uses fossil-burning heating :or appliances or art attached garage:. They shall be installed in accordance with,the F.H.C. 21. All plumbing, mechanical,:and electrical shall be separate from unit to.unit: This includes all. . underground plumbing and electric. 22. All 2011:N.E:C. Codes.will be enforced:. . 23:Tamper=Resistant Receptacles in_.accordarice with 406.11 of the.2011 N.E:C 24-An accordance.with the Land:Development:Code,,lots shall be sodded before final at least 10 . feet'around the structure: 25. A.c®/ly of the energy cacls shall be with:pernaitat all tinges 26 Copy of final insu&tion'report-shall be-provided with permit-before.fiizab P.RE.-Finished Floor Elevation F:B:C=Florida Building Code 6t'Edition - R.O.W.-Right.of Way A.D.A.-Americans with Disabilities ActN.E.C.-National-Electric Code(2011) Lennar Homes-6614 Wagon Trail St•3,046 Sq ft o umn ts SQ. FEET PRICE MAIN OR LIVING: 3,046 $ 112.65 OTHER AREA UNDER ROOF: $ 88.00 OTHER: - $ - VALUATION $ 343,131.90 s- FEE SHEET $ 1,760.00 ADDRESS $ 40.00 DRIVEWAY $ 40.00 BUILDING: $ 1,875.20 ELECTRICAL: $ 396.00 PLUMBING: $ 264.00 MECHANICAL: $ 184.80 SUB-TOTAL $ 2,720.00 TOTAL $ 2,720.00 SEWER: n/a WATER: n/a IRRIGATION: $ - TOTAL: $ - WATER METER: n/a IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 3,273.35 PARK IMPACT FEES $ 769.56 SIF'S: $ 7,128.00 100.0% $ 7,128.00 1.0% $ 71.28 TOTAL: $ 7,199.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 14,874.19 05-26-21-0080-00600-0070 j Pasco County Property Appigjser Page 1 of 1 Data Current as Of: Weekly Archive - Saturday, March 24, 2018 Parcel ID 05=26-21-0089.-'fQ600-0070 (Card: 001 of 001) Classification 00 =-Vacant Residential Mailing Address Property Value LENNAR HOMES LLC Ag Land $0 4600 W CYPRESS ST STE 200 Land $2,413 TAMPA FL 33607-4099 Building $0 Physical Address Extra Features $0 6614 WAGON TRAIL STREET ZEPHYRHILLS, FL 33541 Just Value $2,413 Legal Description (First 4 Lines) Assessed (Non-School Amendment 1) $2,413 SILVERADO RANCH SUBDIVISION PHASES 6, 8 &9A PB 75 PG 075 BLOCK 6 Taxable Value $2,413 LOT 7 Jurisdiction City of Zephyrhills Land Detail (Card: 001 of 001) Line_ _ Use r--_-----F--:-- --�-----, ---- --- -- - DescriptionZoning— Units Type !Price ;Condition jValue 1 — SFR MPUD 6,000.00i—_ SF $0.40 1.00 $2400 0100 $0.25 1.00_1 $,132 Additional Land Information Acres 0.14 Tax Area, 30SI FEMA Residential Code 4 SLVRCPI ea,- - Code-- i Building Information - Use 00 - Unimproved (Card: 001 of 001) Unimproved Parcel 00 - Unimproved Extra Features (Card: 001 of 001) Line -v_ Description junits jValue _ No Extra Features Sales History - See All 6 sales Previous Owner: DUNE FL LAND I SUB LLC Month/Yeari Book/Page jType _-�!D_OR CodeC itionlAmount _ 03/2018 19694 / 3124 j Warranty Deed _ _ ; 05 _ Vacant Multi-Parcel Sale 05/2017 19535 / 0546 j—_--Certificate of Title —1 05 _VacantMulti-Parcel Sale �11/2016 ;9462 0384 jtMineral Rights or Royalty Transfer 05 Vacant Multi-Parcel Sale http:Hsearch.pascopa.com/parcel.aspx?parcel=2126050080006000070 4/2/2018 s- s FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE POR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 2575B1 sf ADS 2017 Builder Name: Lennar Homes Street: 6614 Wagon Trail Street Permit Office: City of Ze hyrhills City,State,Zip: Zephyrhills,FL, Permit Number: l q,661 Owner: ' Lennar Homes Jurisdiction:611600 Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(2613.1 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1264.00 ft2 b.Concrete Block-Int Insul,Exterior R=4.1 996.67 ft2 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 352.44 ft2 4. Number of Bedrooms 4 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (1489.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1489.00 ft2 6. Conditioned floor area above grade(ft2) 2582 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(175.6 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 218.6 a. U-Factor. Dbl,U=0.54 71.25 ft2 b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 298.2 SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.56 71.00 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.28 a.Central Unit 18.0 SEERA6.00 b.Central Unit 25.2 SEER:16.00 c. U-Factor: Dbl,U=0.56 33.33 ft2 SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency d. U-Factor. N/A ft2 a.Electric Heat Pump 17.5 HSPF:8.50 SHGC: b.Electric Heat Pump 21.8 HSPF:8.50 Area Weighted Average Overhang Depth: 1.190 ft. Area Weighted Average SHGC: 0.300 14.Hot water systems 8. Floor Types (2575.0 sqft.) Insulation Area a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 1093.00 ft2 b. Conservation features EF:0.950 b.Floor Over Other Space R=0.0 1049.00 ft2 None c.other(see details) R= 433.00 ft2 15.Credits Pstat Glass/Floor Area: 0.068 Total Proposed Modified Loads: 74.70 PASS Total Baseline Loads: 74.78 I hereby certify that the plans and specifications covered by Review of the,plans and T1S ' C? ._ this calculation are in compliance with the Florida Energy specifications covered by thisp ` Code. calculation indicates compliance �aVe �JAG/, with the Florida EnergyCode. GUl Yl PREPARED BY: Before construction is completed r�si m '' "" ►-,. DATE: this buildingwill be inspected for - _ d P �-��Cl X: _ compliance with Section 553.908 hereby certify that this building,as designed, is in compliance Florida Statutes. with the Florida Energy Code. OWNER/AGENT: UHF BUILDING OFF CIAL: DATE: DATE: 26 - Compliance requires certification tk1sulation air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordanceh R403.3.2.1. -Compliance requires an Air Barrier and Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.070 Qn for whole house. 2/1/2018 8:26 AM EnergyGaugeO USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5 FORM R40k017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 2575B1 sf ADS 2017 Builder Name: Lennar Homes Street: 6614 Wagon Trail Street Permit office: City of Zephyrhills City,State,Zip: Zephyrhills,FL, Permit Number: Owner. Lennar Homes Jurisdiction:611600 Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(2613.1 sgft.) Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1264.00 ftZ b.Concrete Block-Int Insul,Exterior R=4.1 996.67 ftZ 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 352.44 ft2 4. Number of Bedrooms 4 d.N/A R= ftZ 5. Is this a worst case? Yes 10.Ceiling Types (1489.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1489.00 ftZ 6. Conditioned floor area above grade(ftZ) 2582 b.N/A R= ftZ Conditioned floor area below grade(ftZ) 0 c.N/A R= ftZ 11.Ducts R ftZ 7. Windows(175.6 sgft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 218.6 a. U-Factor: Dbl,U=0.54 71.25 ftZ b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 298.2 SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.56 71.00 ftZ 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.28 a.Central Unit 18.0 SEER:16.00 b.Central Unit 25.2 SEER:16.00 c. U-Factor: Dbl,U=0.56 33.33 ftZ SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ftZ a.Electric Heat Pump 17.5 HSPF:8.50 SHGC: b.Electric Heat Pump 21.8 HSPF:8.50 Area Weighted Average Overhang Depth: 1.190 ft. Area Weighted Average SHGC: 0.300 14.Hot water systems 8. Floor Types (2575.0 sgft.) Insulation Area a.Electric Cap:40 gallonsEF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1093.00 ftZ b. Conservation features b.Floor Over Other Space R=0.0 1049.00 ftZ None c.other(see details) R= 433.00 ftZ 15.Credits Pstat Glass/Floor Area: 0.068 Total Proposed Modified Loads: 74.70 PASS Total Baseline Loads: 74.78 hereby certify that the plans and specifications covered by Review of the plans and TI E'Sr this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. F+` iirr '�� •':�� ti, 0 have i! t cl� .. .,., PREPARED BY: Before construction is completed i� R• '` _ �: 99, DATE: this building will be inspected for "• a: compliance with Section 553.908 herebycertify that this building,as designed,is in compliance Florida Statutes. fY 9� 9 P with the Florida Energy Code. cow y�„ ` .• `' OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.070 Qn for whole house. 2/1/2018 8:26 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5 FORM R40k017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 2575B1 sf ADS 2017 Builder Name: Lennar Homes Street: 6614 Wagon Trail Street Permit Office:City of Zephyrhills City,State,Zip: Zephyrhills,FL, Permit Number: Owner. Lennar Homes Jurisdiction:611600 Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(2613.1 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1264.00 ft2 b.Concrete Block-Int Insul,Exterior R=4.1 996.67 ft2 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 352.44 ft2 4. Number of Bedrooms 4 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (1489.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1489.00 ft2 6. Conditioned floor area above grade(ft2) 2582 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(175.6 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 218.6 a. U-Factor: Dbl, U=0.54 71.25 ft2 b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 298.2 SHGC: SHGC=0.31 b. U-Factor: Dbl, U=0.56 71.00 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.28 a.Central Unit 18.0 SEER:16.00 b.Central Unit 25.2 SEER:16.00 c. U-Factor: Dbl,U=0.56 33.33 ft2 SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 17.5 HSPF:8.50 SHGC: b.Electric Heat Pump 21.8 HSPF:8.50 Area Weighted Average Overhang Depth: 1.190 ft. Area Weighted Average SHGC: 0.300 14.Hot water systems 8. Floor Types (2575.0 sqft.) Insulation Area a.Electric Cap:40 gallons EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1093.00 ft2 b. Conservation features b.Floor Over Other Space R=0.0 1049.00 ft2 None c.other(see details) R= 433.00 ft2 15.Credits Pstat Glass/Floor Area: 0.068 Total Proposed Modified Loads: 74.70 PASS Total Baseline Loads: 74.78 hereby certify that the plans and specifications covered by Review of the plans and ;aTk1E..TAT•. '.. S . this calculation are in compliance with the Florida Energy specifications covered by this $Q,. Code. calculation indicates compliance , � �lalGl2 with the Florida Energy Code.aVe PREPARED BY: Before construction is completed c� DATE: this building will be inspected forr��i compliance with Section 553.908 * <> I herebycertify that this building,as designed, is in compliance Florida Statutes. . fY 9, 9 P with the Florida Energy Code. OD`yy =`L OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: " - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.070 Qn for whole house. 2/1/2018 8:26 AM EnergyGaugeO USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5 1 FORM R405-2017 PROJECT Title: 2575B1 sf ADS 2017 Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 2582 Lot# Owner Name: Lennar Homes Total Stories: 2 Block/Subdivision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: Lennar Homes Rotate Angle: 90 Street: Permit Office: Cross Ventilation: County: Pasco Jurisdiction: Whole House Fan: City,State,Zip: Zephyrhills, Family Type: Single-family FL, New/Existing: New(From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Tampa FL_TAMPA INTERNATI 39 91 70 75 645.5 54 Medium BLOCKS Number Name Area Volume 1 Block1 1093 9399.8 2 Block2 1489 11912 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 1st Floor 1093 9399.8 Yes 0 1 Yes Yes Yes 2 2nd Floor 1489 11912 No 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio 1st Floor 102 ft 0 1093 ft2 -__ 0.3 0 0.7 2 Raised Floor 2nd Floor ____ — 13 ft2 11 0 0 1 3 Floor over Garage 2nd Floor ____ ____ 420 ft2 11 0.2 0 0.8 4 Floor Over Other Space 2nd Floor 1049 ft2 0 0.2 0 0.8 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch . # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1613 ft2 0 ft2 Medium 0.85 No 0.9 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 1489 ft2 N N 2/1/2018 8:26 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5 S FORM R405-2017 CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) 2nd Floor 30 Blown 1489 ft2 0.11 Wood WALLS = ` Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 N=>E Exterior Concrete Block-Int Insul 1st Floor 4.0999 19 8 8 164.7 ft2 0 0.600000 0 2 E=>S Exterior Concrete Block-Int Insul 1st Floor 4.0999 38 8 8 329.3 ft2 0 0.600000 0 3 S=>W Exterior Concrete Block-Int Insul 1st Floor 4.0999 34 8 8 294.7 ft2 0 0.600000 0 4 W=>N Exterior Concrete Block-Int Insul 1st Floor 4.0999 18 8 8 156.0 ft2 0 0.600000 0 _ 5 N=>E Garage Frame-Wood 1 st Floor 11 20 8 8 173.3 ft2 0 0.01 0 6 W=>N Garage Frame-Wood 1 st Floor 11 20 8 8 8 179.1 ft2 0 0.01 0 7 N=>E Exterior Frame-Wood 2nd Floor 11 40 8 320.0 ft2 0 0.600000 0 8 E=>S Exterior Frame-Wood 2nd Floor 11 39 8 312.0 ft2 0 0.6 0 9 S=>W Exterior Frame-Wood 2nd Floor 11 40 8 320.0 ft2 0 0.600000 0 10 W=>N Exterior Frame-Wood 2nd Floor 11 39 8 0 312.0 ft2 0 0.600000 0 11 S=>W Exterior Concrete Block-Int Insul 1st Floor 4.0999 6 8 8 52.0 ft2 0 0.600000 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N=>E Insulated 1st Floor None .2 3 6 8 20 ft2 2 N=>E Wood 1 st Floor None .4 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered orientation => changed to Worst Case. / Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 3 S=>W 11 Metal Low-E Double Yes 0.56 0.32 N 33.3 ft2 2 ft 0 in 0 ft 6 in Drapes/blinds None 4 S=>W 3 Metal Low-E Double Yes 0.54 0.31 N 9.3 ft2 1 ft 0 in 10 ft 0 in Drapes/blinds None 5 N=>E 7 Metal Low-E Double Yes 0.56 0.28 N 16.0 ft2 1 ft 0 in 0 ft 6 in Drapes/blinds None 6 S=>W 9 Metal Low-E Double Yes 0.54 0.31 N 23.0 ft2 1 ft 0 in 0 ft 6 in Drapes/blinds None 7 W=>N 10 Metal Low-E Double Yes 0.54 0.31 N 16.0 ft2 1 ft 0 in 0 ft 6 in Drapes/blinds None 8 N=>E 7 Metal Low-E Double Yes 0.56 0.28 N 16.0 ft2 1 ft 0 in 0 ft 6 in Drapes/blinds None 9 S=>W 3 Metal Law-E Double Yes 0.54 0.31 N 23.0 ft2 1 ft 0 in 10 ft 0 in Drapes/blinds None 10 N=>E 1 Metal Low-E Double Yes 0.56 0.28 N 23.0 ft2 1 ft 0 in 10 ft 0 in Drapes/blinds None 11 N=>E 7 Metal Low-E Double Yes 0.56 0.28 N 16.0 ft2 1 ft 0 in 4 ft 0 in Drapes/blinds None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 420 ft2 420 ft2 41 ft 8.6 ft 1 2/1/2018 8:26 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2017 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000367 2486.4 136.5 256.71 .339 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 17.5 kBtu/hr 1 sys#1 2 Electric Heat Pump/ Split HSPF:8.5 21.8 kBtu/hr 2 sys#2 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 16 18'kBtu/hr 540 cfm 0.85 1 sys#1 2 Central Unit/ Split SEER: 16 25.2 kBtu/hr 756 cfm 0.85 2 sys#2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 40 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS —Supply— —Return— Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 218.6 ft 2nd Floor 54.65 ft Proposed Qn 2nd Floor —cfm 76.5 cfm 0.07 0.60 1 1 2 Attic 6 298.2 ft 2nd Floor 74.55 ft Proposed Qn 2nd Floor —cfm 104.2 cfm 0.07 0.60 2 2 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Cooling [[ ]]Jan [[ ]]Feb [[ ]]Mar ` [ ]Apr I JM a rl Jun ri Jul ri Aug Se [ ]Oct [ ]Nov [ ]Dec Heatin [X]Jan [X]Feb ki Mar [ ]Apr May Jun Jul Aug Sep [ ]Oct [ Nov [X]Dec Ventin [ ]Jan [ ]Feb [X]Mar [X]A r May Jun Jul Au Se [X]Oct [X]Nov [ ]Dec 2/1/2018 8:26 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2017 Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 2/1/2018 8:26 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5 r ' FORM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerformance Index, the',more efficient the home. Zephyrhills, FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1264.00 ft2 b.Concrete Block-Int Insul,Exterior R=4.1 996.67 ft 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 352.44 ft2 4. Number of Bedrooms 4 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types Insulation Area a.Under Attic(Vented) R=30.0 1489.00 ft2 6. Conditioned floor area(ft2) 2582 b.N/A R= ft2 7. Windows" Description Area c.N/A R= ft2 a. U-Factor: Dbl,U=0.54 71.25 ft2 11.Ducts R ft2 a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 218.6 SHGC: SHGC=0.31 b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 298.2 b. U-Factor: Dbl, U=0.56 71.00 ft2 SHGC: SHGC=0.28 12.Cooling systems kBtu/hr Efficiency c. U-Factor: Dbl,U=0.56 33.33 ft2 a.Central Unit 18.0 SEER:16.00 SHGC: SHGC=0.32 b.Central Unit 25.2 SEER:16.00 d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 17.5 HSPF:8.50 Area Weighted Average Overhang Depth: 1.190 ft. b.Electric Heat Pump 21.8 HSPF:8.50 Area Weighted Average SHGC: 0.300 8. Floor Types Insulation Area 14.Hot water systems a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 1093.00 ft2 EF:0.95 b.Floor Over Other Space R=0.0 1049.00 ft2 c.other(see details) R= 433.00 ft2 b. Conservation features None 15.Credits Pstat certify that this home has complied with the Florida Energy Efficiency Code for BuildingHES7' Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed ��"nf� �-:',�'.�'t;,,• based on installed Code compliant features. Builder Signature: Date: 9 02/O1/18 � Address of New Home: 6614 Wagon Trail Street City/FL Zip:Zephyrhills,FL 33541*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 2/1/2018 8:27 AM EnergyGauge@ USA-FlaRes2017 -Section R405.4.1 Compliant Software Page 1 of 1 Building Analysis Job: 2575B1 sf ADS g Y Date: 2/1/2018 lower floor By: Dave Bayonet Plumbing Heating and Air Project Information For: Lennar Homes Design Conditions Location: Indoor: Heating Cooling Tampa International AP, FL, US Indoor temperature(OF) 70 75 Elevation: 10 ft Design TD (OF) 39 16 Latitude: 280N Relative humidity(%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 34.7 54.7 Dry bulb(OF) 31 91 Infiltration: Daily range(OF) - 14 ( L ) Method Simplified Wet bulb(OF) - 77 Construction quality Semi-tight Wind speed (mph) 15.0 7.5 Fireplaces 0 • Component Btuh/ft2 Btuh % of load Walls 5.5 5191 31.9 acts Glazing 30.2 2683 16.5 nfiltration Doors 21.2 432 2.7 Wall Ceilings 1.7 60 0.4 Floors 4.1 4478 27.5 Infiltration 1.9 2039 12.5 Ducts 1400 8.6 Piping 0 0 Floors Humidification 0 0 Glazing Ventilation 0 0 Doors other Adjustments 0 Total 16284 100.0 Component Btuh/ft2 Btuh % of load Walls 2.8 2641 23.2 Internal Gains Glazing 56.3 5004 44.1 Walls Doors 16.6 338 3.0 Ceilings 2.0 67 0.6 Ducts Floors 0 0 0 Infiltration 0.4 454 4.0 Ducts 1655 14.6 nfiltration Ventilation 0 0 other Internal gains 1200 10.6 Doors Blower 0 0 Adjustments 0 Total 11360 100.0 Glazing Latent Cooling Load= 1237 Btuh Overall U-value.= 0.150 Btuh/ft2-°F Data entries checked. +- + wrightsoft® 2018-Feb-01 08:38:30 Right-Suite®Universal 2017 17.0.23 RSU05714 Page 1 ...A27UHE AH's125758 sf ADS template 1.5-2 ton.rup Calc=MJ8 Front Door faces: W Building Analysis Job: 2575B1 sf ADS g y Date: 211/2018 upper floor By: Dave Bayonet Plumbing Heating and,Air Project Information For: Lennar Homes Design C• • • Location: Indoor: Heating Cooling Tampa International AP, FL, US Indoor temperature(OF) 70 75 Elevation: 10 ft Design TD (OF) 39 16 Latitude: 28°N Relative humidity(%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 34.7 54.7 Dry bulb(OF) 31 91 Infiltration: Daily range(OF) - 14 ( L ) Method Simplified Wet bulb(OF) - 77 Construction quality Semi-tight Wind speed(mph) 15.0 7.5 Fireplaces 0 Component Btuh/ft2 Btuh % of load Walls 3.8 4204 32.8 ucts Glazing 30.2 2608 20.3 Doors 0 0 0 wall Ceilings 1.3 1868 14.6 Floors 0 0 0 nfilbaton Infiltration 1.9 2299 17.9 Ducts 1846 14.4 Piping 0 0 Humidification 0 0 Ceilings Ventilation 0 0 Glazing Adjustments 0 Total 12825 100.0 Component Btuh/ft2 Btuh % of load Walls 2.7 3035 16.5 Walls Glazing 52.9 4568 24.8 Doors 0 0 0 Internal Gains Ceilings 1.7 2583 14.0 Floors 0 0 0 Infiltration 0.4 512 2.8 Ducts 2137 11.6 Ventilation 0 0 Glazing Internal gains 5615 30.4 Blower 0 0 Ducts Adjustments 0 Infiltration Total 18450 100.0 Ceilings Latent Cooling Load= 3541 Btuh Overall U-value= 0.083 Btuh/ft2-°F Data entries checked. t - - wrightsoft- 2018-Feb-01 08:38:30 ACCA Right-Suite(E)Universal 2017 17.0.23 RSU05714 Page 2 ...A27UHE AH's\25758 sf ADS template 1.5.2 ton.rup Calc=MJ8 Front Door faces: W Project Summary Job: 2575B1 sf ADS Date: 2/11201 S lower floor By: Dave Bayonet Plumbing Heating and Aire Project Information For: Lennar Homes Notes: Design Information Weather: Tampa International AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 31 °F Outside db 91 °F Inside db 70 °F Inside db 75 °F Design TD 39 °F Design TD 16 °F Daily range L Relative humidity 50 % Moisture difference 55 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 14883 Btuh Structure 9705 Btuh Ducts 1400 Btuh Ducts 1655 Btuh Central vent(0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh none (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 16284 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 11360 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 942 Btuh Ducts 294 Btuh Central vent(0 cfm) 0 Btuh Heating Coolingg (none) Area(ft2) 1093 1093 Equipment latent load 1237 Btuh Volume(ft') 9654 9654 Air changes/hour 0.29 0.16 Equipment Total Load (Sen+Lat) 12596 Btuh Equiv.AVF(cfm) 47 25 Req. total capacity at 0.85 SHR 1.1 ton Heating Equipment Summary Cooling Equipment Summary Make Lennox Make Lennox Trade 14HPX SERIES Trade 14HPX SERIES Model 14HPX-018-230-21 Cond 14H PX-01 8-230-21 AHRI ref 10258596 Coil CBA27UHE-018-230*++TDR AHRI ref 10258596 Efficiency 8.5 HSPF Efficiency 13.0 EER, 16 SEER Heating input Sensible cooling 16915 Btuh Heating output 17100 Btuh @ 47°F Latent cooling 2985 Btuh Temperature rise 26 °F Total cooling 19900 Btuh Actual air flow 600 cfm Actual air flow 600 cfm Air flow factor 0.037 cfm/Btuh Air flow factor 0.053 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.90 Capacity balance point= 31 °F Backup: Input=4 kW, Output= 15295 Btuh, 100 AFUE Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsoftm 2018-Feb-01 08:38:30 Right-Suited Universal 2017 17.0.23 RSU05714 Page 1 ...A27UHE AH's\25758 sf ADS template 1.5.2 ton.rup Calc=MJS Front Door faces: W Project Summary Job: 2575B1 sf ADS Date: 211/2018 upper floor By: Dave Bayonet Plumbing Heating and Air Proiect Information For: Lennar Homes Notes: Design Information Weather: Tampa International AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 31 OF Outside db 91 OF Inside db 70 OF Inside db 75 OF Design TD 39 OF Design TD 16 OF Daily range L Relative humidity 50 % Moisture difference 55 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 10978 Btuh Structure 16313 Btuh Ducts 1846 Btuh Ducts 2137 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 12825 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 18450 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 3162 Btuh Ducts 379 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling (none) Area(ftz) 1489 1489 Equipment latent load 3541 Btuh Volume(ft') 11912 11912 Air changes/hour 0.27 0.14 Equipment.Total Load (Sen+Lat) 21991 Btuh Equiv.AVF (cfm) 53 29 Req. total capacity at 0.85 SHR 1.8 ton Heating Equipment Summary Cooling Equipment Summary Make Lennox Make Lennox Trade 14HPX SERIES Trade 14HPX SERIES Model 14HPX-024-230-21 Cond 14HPX-024-230-21 AHRI ref 10258598 Coil CBA27UHE-024-230*++TDR AHRI ref 10258598 Efficiency 8.5 HSPF Efficiency 13.5 EER, 16 SEER Heating input Sensible cooling 21420 Btuh Heating output 21800 Btuh @ 47°F Latent cooling 3780 Btuh Temperature rise 25 OF Total cooling 25200 Btuh Actual air flow 800 cfm Actual air flow 800 cfm Air flow factor 0.062 cfm/Btuh Air flow factor 0.043 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.84 Capacity balance point= 17 OF Backup: Input= 3 kW, Output= 11787 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -F 1- wrilghtsoft- 2018-Feb-01 08:38:30 C Right-Suite®Universal 2017 17.0.23 RSU05714 Page 2 �� ...A27UHE AH's12575B sf ADS template 1.5-2 ton.rup Calc=MJ8 Front Door faces: W Manual S Compliance Report Job: J2575B1 sf ADS p p Date: 2H/2018 lower floor By: Dave Bayonet Plumbing Heating and Air Project Information For: Lennar Homes -- Cooling Equipment Design Conditions Outdoor design DB: 91.3°F Sensible gain: 11360 Btuh Entering coil DB: 75.8°F Outdoor design WB: 77.3°F Latent gain: 1237 Btuh Entering coil WB: 62.9°F Indoor design DB: 75.0°F Total gain: 12596 Btuh Indoor RH: 50% Estimated airflow: 600 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: SpIitASHP Manufacturer: Lennox Model: 14HPX-018-230-21+CBA27UHE-018-230*++TDR Actual airflow: 600 cfm Sensible capacity: . 15300 Btuh 135% of load Latent capacity: 2700 Btuh' 218% of load Total capacity: 18000 Btuh 143% of load SHR: 85% Heating Equipment Design Conditions Outdoor design DB: 30.8°F Heat loss: 16284 Btuh Entering coil DB: 69.6°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: SpIitASHP Manufacturer: Lennox Model: 14HPX-018-230-21+CBA27UHE-018-230*++TDR Actual airflow: 600 cfm Output capacity: 17500 Btuh 107% of load Capacity balance: 31 OF Supplemental heat required: 0 Btuh Economic balance: -99 OF Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 600 cfm Output capacity: 4.5 kW 94% of load Temp. rise: 50 OF Meets are all requirements of ACCA Manual S. wri htsoft9 2018-Feb-0108:38:30 9 Right-Suite®Universal 2017 17.0.23 RSU05714 Page 1 ...A27UHE AH's12575B sf ADS template 1.5-2 ton.rup Calc=MJB Front Door faces: W / 1 sf ADS Manual S Compliance Report Job: 2Date: 2575B575B 8 upper floor By: Dave Bayonet Plumbing Heating and Air Project I • • For: Lennar Homes Cooling Equipment Design Conditions Outdoor design DB: 91.3°F Sensible gain: 18450 Btuh Entering coil DB: 75.6°F Outdoor design WB: 77.3°F Latent gain: 3541 Btuh Entering coil WB: 62.8°F Indoor design DB: 75.0°F Total gain: 21991 Btuh Indoor RH: 50% Estimated airflow: 800 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: SplitASHP Manufacturer: Lennox Model: 14HPX-024-230-21+CBA27UHE-024-230*++TDR Actual airflow: 800 cfm Sensible capacity: 21420 Btuh 116% of load Latent capacity: 3780 Btuh 107% of load Total capacity: 25200 Btuh 115% of load SHR: 85% Heating Equipment Design Conditions Outdoor design DB: 30.8°F Heat loss: 12825 Btuh Entering coil DB: 69.6°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Lennox Model: 14HPX-024-230-21+CBA27UHE-024-230*++TDR Actual airflow: 800 cfm Output capacity: 21800 Btuh 170% of load Capacity balance: 17 OF Supplemental heat required: 0 Btuh Economic balance: -99 OF Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 800 cfm Output capacity: 3.5 kW 92% of load Temp. rise: 50 OF Meets are all requirements of ACCA Manual S. � J} wri htsoft' 2018-Feb-01 08:38:30 �� I 9 Right-Suite®Universal 2017 17.0.23 RSU05714 Page 2 14CC�, ...A27UHE AH's%2575B sf ADS template 1.5-2 ton.rup Calc=MJB Front Door faces: W Lennar Homes-6614 Wagon Trail St-3,046 sq ft Column SQ. FEET PRICE MAIN OR LIVING: 3,046 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 343,131.90 FEE SHEET $ 1,760.00 ADDRESS $ 30.00 DRIVEWAY $ 45.00 BUILDING: $ 1,870.20 ELECTRICAL: $ 396.00 PLUMBING: $ 264.00 MECHANICAL: $ 184.80 SUB-TOTAL $ 2,715.00 TOTAL $ 2,715.00 SEWER: n/a WATER: n/a IRRIGATION: $ - TOTAL: $ - WATER METER: n/a IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 3,268.35 PARK IMPACT FEES $ 769.56 SIF'S: $ -4,828. 100.0% $ 4, Rf 00 1.0% $ 48. TOTAL: $ 44,876.28 T 1 F'S: $ 3,632.00• . 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 12,546.19 f j f L PASCO COUNTY, FLORIDA Permit No. • t d Date Permitted - -1 Builder Name/Owner Name k". ��S Control#' . County Parcel No. �S' � x7 .0 d0 (?C)�O SubDiv: S' L��&-db Address/Location 7' - -7—e-At �9 1(4 ClassificationRype of Use TRANSPORTATION IMPACT FEE. Rate: Sq.Ft Unit: , Exempt []Yes ❑ No How Determined Impact Fee Amount $. 1 .� v V Zone No. TAZ: SCHOOL IMPACT FEE Account (056) Single-Family Detached House Amount $ Ai i 2. • (057) Mobile Home (058) Other Residential 123) Collection Fee Exempt [ Yes ❑ No How Determined PARKS AND RECREATION FEE Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation Total Zone TOTAL AMOUNT $ (pq. ► Exempt ❑ Yes ❑ No How Determined 1 LIBRARY FEE Land Account Land Credit Land Total Facility Account Facility Credit Facility Total Exempt ❑ Yes ❑ No How Determined Total Amoun RESOURCE FEE 1 ERU TOTAL AMOUNT Prepared By Q Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE . BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY Acknowledgement below does not Imply acceptance of concurrence,but simply receipt of-a copy of this form,placing the building permit owner on notice of this assessment and the conditions of payment for same. DATE RECEIVED BY RECEIPT NO. DATE BY IT501 Vq Jet-StreamO Ultra Blowing Wool Insulation NAU 0 Attic and Cavity Wall Card ej h i4y r �me. e, iuj� & ' � Batts"afid Blankets lqtfloment Required' When installed in accordance with the manufacturer's It is recommended that a pneumatic blowing machine and a corrugated hose vilth a minimum 1W internal corrugation,a minimum length recommendations,Knauf Insulation batts and blankets will of 160'.Colls-In the hose should not be toss than 36"in diameter.Acceptable material feed late is 5-35 lbs/minute.Reedirrinitrided feed provide the full R-value. rate is 15-25 lbslmiinute. R-Value* Minimum Thickness Thermal Performance(Sidewall and Attic Applicati6h) To cbtaln an The stated theirnal resistance(R-value)Is provided by Installing in accoiclanbe volth the manufacturer's Instructions.Failure to install the Insulation resistance Installed I,nsulailan should required number of bags per 1,000 square feet and exceeding*the maximum square feet of coverage per bag as recommended by thb label (R-value)of: not be less than: will result in lower installed k-values.Field blending.of this product with other.loose fill insulations Is not recommended by the manufacturer. R49 -11757 Cavity W611 Bag Net Weiiliiht=Nomlnal 32 lbs.,Minimum 31 lbs. R-38HD 10.25" R-38 12.00" R-Value` Bags per 1000 SF Maximum Net Minimum R-30HD 8.25" Toobtalia"an The number of hags Coverage per Bag Weight per SF Insulation per 1,000 squa-ire feet contents of this The -eightper square R-30 10.00" Cavity resistance of net area should not bag should not fact of Installed Insulation R-26 9.-00" Framing Depth of.. Density, be'less than: cover more than: should net be iess than: R-22 6,50" 2"x 4" 3.5.0' R-1 5 1.8 lbs./cu,ft. 16.4 bags 01.0 sq.ft, 0,525.Op. R-21 HID 5.60" 2"x 6" 5.50" R-23 1.8 lbsJcu.ft. 2.5.8 bags 38.8 sq.ft. 0.825 tbs. R-1 9 6,25"" R-15HD 3.60" 2N 9 8" 7.25" R-�l 1.8 lbs./cu.ft. 34.0 bags 29.4 sq.ft. 1,08 Ibs. 1 - -1 1 . R-13 -3.50'. ?-X 10" 1 9.25- --R-39 ta Ibsku-.1 43.4 bags 23.1 sq.ft. 1.388 lbs: R-11 3.50"- 'Rmeans resistance to heat flow.The higher the R-vakie.thogroatarthe Insulating power.To gel the marked R.value,it is essential that this Insulation be lnstanLd properly. R-8 2.50" "R-18 in a 5.5,cavity.Conforms IoASTMC 65'and Federal Open Attic Application Bag Net Weight.-Nominal 32 lbs.i Minimum 31 lbs. M� 11111mum Bags/ Maximum Minimum Initial "Settled Framing Adjustment I. 000 SF Coverage Weight Installed -Thickness** To compensate for framing members,the number of bags per The number of balls/ Contents of this The welghtfsF Thickness Cofnioha of this 1,000 sq.ft.of area to be Insulated should he as shown below. K-Value* 1,000 SF of net area bag shtiuld not of Installed Instal ad Insulation bag should To obtain an Insulation should not be less cdVef insulation should not should'not be less, not cover more .Bags/MSF Ba s/MSF n: 9 resistance(R-Value)of: than: more than: be less than than: Joist 16"O.C. 24"O.C. R-Value Dimensions Framing lfrr�m.I n.g R-60 29.7 33.6-SF .952 lbs. 19.750' 19.750" 2k4 29.2 29.4 R-49 23.5. 42i5 SF 753 lbs, 16,375' 16375" ' 2x8 28.9 Z.1 R44 :20.9 47.8 SF .670lbs. 14.876" 14.875" 2x8, 28.6 28.9 R-38 17.8 56.2 SF .6-69 lbs. 13.000, 13,000" 2A 23.0, .23.2 R-30 13.6 71 .Sf` A37'Ibs. 10.1375' 10375" R-49 26: 22.7 22.9 R-26 -11.8 85.O'SF .377 lbs. 9j25" 9.1-25" 2x8 22.4 22.7 R-22 9.8 '102.2 5F .313 lbs. 7.750" 71750' 2x4 20.4 20,6 R-44 2x6 20.1 20.3 R-19 8.4 119.3 SF 268 lbs. 13'.7507 6.7.50" 2x8 19.8 20.1 0.1 R-11 3 5.7 175.3 .3 SF .183 lbs. 4.750" 4,7 5.0" 2x4 17.3 17.4 R-11 4.7 210.8 SF A 52 lbs; 4.000" 4.000" R;36 2x6 .17.0 17.2 Bag Net Weigld-Norrdnol 32lbs4 Walaw 31 lbs. 2x8 16.7 17.0 CLY."o and lasb1lawn"were deenined 641 a V¢u-fdak'll*-:-g madhine 6 M gov brit O'lin ape*g,2.0 pi u!r pssm and I 60'of 3:inte.Mr<=?ja'_-d h.,so, 2A 13.2 13.3 This prodmtonformsto ifte perbw�m req61ro*rasdASTM C 764.Tyod 1..rd Wooded FederalSpe6fooh H+1.1030B.Type 1:Class B.-R-VACS GM_deWrM1r*d In D=rdM With.P6117 and C 5.18. 'Wrnems reslslanat5hoa:ftw.The Idgher 1W R,a!N,theg,oalaef Vie a iz�at,lj pb;v7.To get mer.Aedl R-4ue.il is esge nfd oat ads t*VOls!. ad Property.11)�doftyotffSdf,qatifta.. R-30 2x6 12.9. 13.1 t;.s and 1.11ow ceem meMly.lastr�xtiohs do nok,cc mie s;V1 Oi.pio..Go. "83se6 an Third Pony 2-jew sc-Ing sldy,and pred6ed coloMm over a nyvi period wren bA I Ortan!of loss.This m*ml of se�g is ooxrA lr,�jnifwl Thedoro,N .o imOd laid rLW- 2x8 12.6 '12.9- Ikkn a sscs qe_0-04 is sane, 2x4 11.3 11.4 Nlo!u IWO Is 9 regiVwred Mvnark qlif:sul, R-26 2x6' 11.0 11,2 Builder's Insulation-Statement 2x8 10:8 11.0 Jet Strearn Ultra has been Installed in Conformance with the included recorrimenclations.to provide a thermal resistance of. 2x4 9.3. 9.51 R-Value Thickness R-22 2x6 9.1 9.3 Attid'Afeei R. at ... Inches 2x8 8.8 9A Sloped Ceilings at Inches 2x4 7;9 8.1 Walls---- R- at Inches R-11.9 2x6 7.7 7.9 2x8 7.4 7.7 Floors(over an unheated drawl space) R- at Inches 2x4 5.3 5A Crawl Space Perimeter R- at Inches R-1 3 2x6 5.0 5.2 bate.Installed u) Ir 2x8 4.8 5.0 Blown insulation has been installed in conformance with the above bove recommendatiQns to provide an k-value of: 2x4 4.3 4.4 R- 7,ef) using 7 1 bags of this insulation to cover. square'feel of area R-1 1 2x6 4.1 4.3 at minimum thickness of inches. 2x8. 3.8 4.1 En.4-nt 4 fj GREENGUAW 0.0- 71(ifi__L­9 iZ;LA.If eA '12-ollir K-J In 1,Mep UL E.*­CMIENGUARD Gold­d i, compe'ny- Date U,E,,[,­m!.W-h.b.6-IdAyd.h. LM 0 'U'L'_6V6­m GREENGUARD Home Builder(signature) Cad;k,.?,in P-g-nt" pid�..­6d a Lft EmIw4m GPEEUARD b did,f.low 0-kid company Dale L-1-indoor 4 dA%pd�6.9".Fa . 0,11 J­/". The coverage Information on this Attic/Sidewall card applies to the entire drilted States(Including Minnesota). www.knaufinsulit.ion.us Kfiatif Insulation,Inc. One Knauf Drive,Shqlbyville,IN 46176 Tel:(800)8254434 ext.B300 FAX:(317)398-3675 KAMM When 13.11ding,TWk.W.I.it— ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Envelope Leakage Test Report Prescriptive and Performance Method Project Name: /,,,07 Builder Name: L 6 Street: &/',/4 11JW60'-J TIOtIl— J Permit Office: City, State, Zip: PermItNumber, Design Location: Jurisdiction: Envelope Leakage Test Results Single Point Test Data: HOUSE PRESSURE: FLOW: — S Leakage Characteristics Pass Fail 121P ACH(50): 7�-40 S R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zones I and 2 ...Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105(3)(f), (g), or(I)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope, 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended Infiltration control measures; 3.Interior doors,If installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,If installed at the time of the test,shall be fully open I hereby certify that the above envelope leakage Where required by the code official, testing shall be performance results demonstrate compliance with conducted by an approved third-party. A written report of Florida Energy Code requirements in ccordance with the test results shall be signed by the third party 12 -7 " section R4024z7w conducting the test and provided to the code official. SIGNATURE: . PRINTED NAME: BUILDING OFFICIAL: DATE: '9 2/C-5 DATE: Testing was conducted In accordance with ANSIIRESNETACC 380 to meet the 2017 residential energy code. PASCO BOUNTY, FLORIDA Permit No. d l -- Date Permute _ � Builder Name/Owner Name kt1W ULy(A;tfl.s Control W County Parcel No, OS- '�»� x3�(�(2 dO�d o subbivc 31 040,eA r-6 Address/Location O—rfm Classilication/Type of Use• TRANSPORTATION IMPACT FEE - Rate: Sq.Ft Unit: Jac f�4`ki Exempt ❑Yes ❑No / Hove Determined Impact Fee Amount Zone No. TAZ: SCHOOL IMPACT FEE Account (056) Single-Family Detached House Amount. (0557) Mobile Home (058) Other Residential cv� 123) Collection Fee v Exempt [ Yes [2 No How Determined PARKS AND RECREATION FEE Land Account Land Credit Land Total Recreation Account recreation Credit -Recreation Total Zone TOTAL AMOUNT $ ­7(o 5( Exempt ❑Yes No How Determined LIBRARY FEE Land Account Land.Credit Land Total Facility Account Facility Credit Facility Total Exempt []Yes n No How Determined Total Antounfql RESOURCE FEE ERU 'TOTAL AMOUNT Prepared By Chocked By NO CERTIFICATE OF OCCUPANCY 1NILL.BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE .BEEN PAID AND ` RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE.OF PASCO COUNTY Acknowledgement below does not imply'acceptance of concurrence,butslmply receipt of a copy of this form,placing the bolding permit owner on notice of this assessment and tha conditions of payment for same. DATE RECEIVED BY RECEIPT NO. DATE BY :--:4f- WEINTRAUB i INSPECTIONS &FORENSIC,INC. 3868 Sun City Center Blvd.. Ph. 813-633-8000 Sun City Center,Fl.33573 Fx. 813-464-8026 CONCRETE SLABIFO LNDA: IN`SECTION REPORT INSPECTION DATE: 06/18/2018 CLIENT/Community: D.P H-TAMPA/ Silverado LOT#(s)/ADDRESS: # 32/6 / 6605 Wagon Trail SUPERINTENDENT: Chris Tallant WEATHER: 80 sunny INSPECTION CRITERIA/PROTOCOL OBSERVED&INSPECTED PASS FAIL 1. Verify Soil Compaction Report in permit box(if req. by jurisdiction X 2. Verfiy slab thickness formed is per permitted plans X 3. Verify exterior wall footing excavation free of debri X 4. Verify exterior wall footing reinforcing steel size and quantity per plans X 5 Verify isolated or monolithic footing pad reinforcing steel size and quantity X are per plans 6. Verify isolated or monolithic footing pad locations are per plans X 7' Verify that all continuous interior monolithic thickened slab foundations are width and depth per plans % 8' Verify that all continuous interior monolithic thickened slab foundations are correctly located per plans % 9 Verify slab welded wire reinforcing is gage and grid dimension specified on % plans Verify that all welded wire slab reinforcing is lapped per plans or Code 10. referenced standard whichever is greater X 11. Verify that all welded wire slab reinforcing is properly chaired each way at X 36"o/c 12. Verify vapor barrier is per plans for type and millage X 13. Verify vapor barrier is installed in accordance with manufacturer's X recommendations 14. Verify all seams are taped and conduit penetrations taped X WEINTRAUB INSPECTIONS &FORENSIC,INC. 3868 Sun City Center Blvd. Ph.813-633-8000 Sun City Center,Fl.33573 Fx.813-464-8026 15. Verify isolation pipe chases installed at plumbing penetrations through X footing two(2)pipe-sizes greater than penetrating pipe. 16. Verify that special arching reinforcing steel in footing is installed at pipe X penetrations per architectural detail Verify ufer-ground properly sleeved thru footing and Installed in accordance 17. with permitted plans and FBC;where attached to footing rebar eliminate X vapor barrier under footer for 20 foot length at connection 18 Verify masonry wall dowel installation for size,placement,Location, % clearances&size per permitted plans Comments: RESULTS INSPECTION ITEMS NOT CHECKED PASS AND FAIL INDICATES NOT APPLICABLE Pass (*)re-inspection required for failed inspections INSPECTED BY: Sean Cyr Inspectors Name scyr@weintraubinspections.com Email address 813.853.4313 Phone# 5335-8TH STREET (813)780-0020 CEilFTCATE OF OCCUPANCY Address; 8614 WAGON TRAIL ST ZEPHYRHILLS, FL. Owner: LENNAR HOMES LLC Subdiv: SILVERADO 4600 W CYPRESS ST STE 200 Parcel: 05-26-21-0080-00600-0070 TAMPA FL 33607-4099 Work Type: 101-NEW CONST/SFR Construction Type: NOT APPLICABLE ❑ Sprinklers Use Classification: NOT APPLICABLE Permit Number: 19509 Date- 7/12/2018 %SUED Y: BUILDI �OF�FICIAL WATER MUST BE CHANGED OVER WITHIN 10 DAYS OF ISSUANCE BAGE DEPOSIT MUST BE APPLIED FOR PRIOR TO ISSUANCE