Loading...
HomeMy WebLinkAbout18-19511 CITY OF ZEPHYRHILLS 5335-8TH STREET-: (813)780-0020 X49511 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL PERMIT INFORMATION LOCATION INFORMATION Permit#:19511 Issued: 4/02/2018 Address: 6600 WAGON TRAIL ST Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Lot(s)�: Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 267,656.40 Total'Fees: 14,227.91 Subdivision: SILVERADO Amount Paid: 14,227.91 Date Paid: 4/03/2018 Parcel Number: 05-26-21-0080-00600-0090 CONTRACTOR INFORMATION OWNER INFORMATION Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC Addr: 4600 W. CYPRESS ST STE 200 Address: 4600 W CYPRESS ST STE 200 TAMPA, FL. 33607 TAMPA FL 33607-4099 Phone: (813)574-5743 Lic: Phone: Work Desc: CONSTRUCT SINGLE FAMILY 2,376 SQ FT APPLICATION FEES ' BUILDING FEE 1,482.60 ELECTRICAL FEE 310.50 PLUMBING FEE 207.00 MECHANICAL FEE 144.90 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE-sfr/100% 4,828.00 SCHOOL IMPACT FEE-sfr/1% 48.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32 SCHOOL IMPACT FEE NEW 2,206.68 SCHOOL-SFR NEW 2% 45.04 Inspection' Re fired FOOTER 2ND ROUGH PLUMB MI INSULATION CEILING FOOTER BOND DUCTS INSULATED WER MISC. ~ ROUGH ELECTRIC LINTEL MISC MISC. _ 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.30(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may resuit in your paying twice for improvements to your property. If you intend to obtain financing, consult�Afith your,•lender or an attorney before recording your notice of commencement." Complete Plans,Specifications and Must Accompany Application. All v ork shall be performed in accordance with City Codes and Ordinances. NO OCCUR;++ICY BEFORE C.O. NO OCCUPANCY BEFORF C.O. 1 � L TRACTORS SIG TURE PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 19511 BUILDING-P RMIT SINGLE FAMILY RESIDENTIAL PERMIT-INFORMATION 10CATION INFORMATION Permit#:19511 Issued- 4/02/2018 Address: 6600 WAGON TRAIL ST Permit Type: NEW PINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 101-N CONST/SF Township: Range: Proposed Use: NOT AP CABLE Lot(s):' Block: Section: Sq. Feet: Est. e: Book: Page: Cost: 267,656.40 Total Fe 11,976.19 Subdivision: SILVERADO Amount Paid: 11,976.19 Date a . : 4/02/2018 Parcel Number: 05-26-21-0080-00600-0090 CONTRACTOR INFORMATION"-, OWNER INFORMATION Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC Addr: 4600 W. CYPRESS ST S E 200 Address: 4600 W CYPRESS ST STE 200 TAMPA, FL. 33607 TAMPA FL 33607-4099 Phone: (813)574-5743 Lic- Phone: Work Desc: CONSTRUCT SINGLE FAMILY 2,376 FT APPLICATION FEES BUILDING FEE 482.60 ELECTRICAL FEE 310.50 PLUMBING FEE 207.00 MECHANICAL FEE 144.90 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE-sfr/100% 4,828.00 SCHOOL IMPACT FEE-sfr/1% 48.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32 - Inspections Required FOOTER 2ND ROUGH PLUMB Misc INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans, Specifications and Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CTORS SIGNATURE PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER PASCO COUNTY, FLORIDA Permit No. t 6 Z l Date Permitted 4-2-19 Bultder Name/Owner Name �6yYit°-5 Control#­ j County Parcel No. �7-24-4(-DUOD-•'DI)�iZ C*CtDS-u--b-Div: S t.I.12ifa. AddresslLocation ClassificationlType of Use i TRANSPORTATION IMPACT FEE Rate: Sq_R Unit: 2� 3Zk Exempt []°Yes ❑No How Determined ifripact Fee Amount $ �, .�°j2. Zone No. TAZ: 5CHOOL IMPACT FEE Account (055) Single-Family Detached House Amount $ . J j (.m. o(7 (05T) Mobile Home (058) Other Residential f 23) Collection Fee Exempt []Yes "No How Determined PARKS AND RECREATION FEE Land Account Land Credit Land Total Recreation Account Recreation Credit �Recreatlon Total Zone TOTAL AMOUNT $ C` � 5L Exempt ❑Yes n No How Determined LIBRARY FEE Land Account Land Credit Land Total Facility Account Facility Credit Facility Total Exempt []Yes No How Determined Total Amount RESOURCEFEE ERU TOTAL AMOUNT Prepared By Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR,FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE BEEN PAID AND RECEIPTED FOR SY A"CENTRAL PERMITTING OFFICE OF PASCO COUNTY Acknowledgement below does not imply acceptance of concurrence,but simply receipt of a copy of this form,placing the building permit owner on notice of this assessment and the conditions of payment for some. DATE RECEIVED BY RECEIPT NO. DATE BY 5335 - 8TH STREET (813)780-0020 CERTIFICATE OF OCCUPANCY Address: 6600 WAGON TRAIL ST Owner: LENNAR HOMES LLC ZEPHYRHILLS, FL. 4600 W CYPRESS ST STE 200 Subdiv: SILVERADO TAMPA FL 33607-4099 Parcel: 05-26-21-0080-00600-0090 Work Type: 101-NEW CONST/SFR Construction Type: NOT APPLICABLE ❑ Sprinklers Use Classification: NOT APPLICABLE Permit Number: 19511 D 7/12/2018 floe- ISSUE[YI' Y: BUILDI OFFICIAL : WATER MUST BE CHANGED OVER WITHIN 10 DAYS OF ISSUANCE GARBAGE DEPOSIT MUST BE APPLIED FOR PRIOR TO ISSUANCE CITY OF " NOTICE ' / / BUILDING ZEPHYRHILLS DEPARTMENT OF ADDITION OR: CORRECTION D • NOT REMOVE ADDRESS DATE PERMIT O 951� -Z THIS JOB HAS NOT BEEN COMPLETE , The following additions or corrections shall be made before the job will be accepted. Lf D r b O U �/ t ' It is unlawful for any Carpenter,Contractor,Builder,or other persons,to AFTER CORRECTIONS ARE ADE CALL cover or cause to be covered,any part of the work with flooring,lath,earth 780-0020 FOR RE-IN CTION or other material,until the proper inspector has had ample time to approve the installation. / OFFICE HOURS 7:30AM-4:30 PM MON.-FRI. INSPECTOR 1 CITY OF / / / BUILDING ZEPHYRHILLS DEPARTMENT OF ADDITION OR CORRECTION D • NOT - • ADDRESS DATE PERMIT ��� Loo Ulfa,.// - THIS JOB HAS NOT BEEN COMPLETED. The following additions or corrections shall be made before the job will be accepted. Wall /4 LiZeC&A 4 1-0-7ch &zz L-P a It is unlawful for any Carpenter,Contractor,Builder,or other persons,to AFTER CORRECTIONS ARE MADE CALL cover or cause to be covered,any part of the work with flooring,lath,earth 780-0020 F RE-IN PECTION or other material,until the proper inspector has had ample time to approve the installation. OFFICE HOURS 7:30AM-4:30 PM MON.-FRI. INSPECTOR CITY OF / / BUILDING ZEPHYRH,ILLS DEPARTMENT OF ADDITION OR CORRECTION D • NOT REMOVE ADDRESS DATE /y PERMIT f THIS JOB HAS NOT BEEN COMPLETED. The following additions or corrections shall be made before the job will be accepted. ,e e ; a x It is unlawful for any carpenter,Contractor,Builder,or other persons,to AFTER CORRECTIONS ARE MADE CALL cover or cause to be covered,any part of the work with flooring,lath,earth 7g0-0020 FOR RE-INSPECTION or other material,until the proper inspector has had ample time to approve the installation. OFFICE HOURS 7:30AM-4:30 PM MON.-FRI. INSPECTOR j' r 0 J J�tito'Lo Ultr Blowing Wool Insulation kI U Attic and Cavity Wall Card .. - :';< r i hme,h we,erfe-Jy Batts and Blankets Equipment Required When installed in accordance with the manufacturer's It is.rlxxJrn wrided that a pneumatic bbWA) machine_and a corrugated hose with a rnfmmum%'internal corrugation,a minimum length Tecccrimendatrons.Knauf Insulation baits and blankets will of 15fY.Call in the hose should not be less than-- in diametco"ble material feed rate is 5-35 WIminute Recommended feed Provide the full R-value rate is 15 25 minute R-Value* Minimum Thickness Thermal, rmance(Sidewall and Attic Application) io ohtatn an The stated >xnce(R.value)is provided by.iestalling in accordance with the manufacturers instructions.Failure to install the insulation rtrsistanco 'Installed insulation should required riu _ s per 1;060 square feet and exceeding,the maximum square feel of coverage per bag as recommended by the label (R-Value)oh not be lou then: will result in loxer.inswed R•values.Field blending of this product with other loose fill insulations is not recommended by the manufacturer. 13-49 13.75 Cavity Wall Bag Net Weight---Nominal 321bs:,Minimum 31 Ills. R-38HD 10.25' - --- Net Minimum R-38. 12,00• R-Value* Bags par 1000 SF Maximumper Bag Weight per SF R_30HD 8.25' To obtain an The numberof bags Coverage p 9. A Insulation par 1.000 sgaoro feet Contents of this The weight persquar• R-30 10.00' Gavlty roiislanw of'not area should not bag should not fact of installed insulation R-25 9.00' Framing De t6 of: Density be less than: co"r'mom than: should not be loss than: R-22 6.5D' 7x 4' 9.54' R-15 1.8 ibslou.ft. 16A bags 611.0.sq.ft. 0.525 lbs. R-21 HD 5.50' 7x 6' 5.50' R-23 1.8 IbsJcu.ft. 25.8 bags 38.8 sq.ft 0.825 lbs. R-19 6:25"' R-75HD 3.50' 2'x 8' 7.25' R-31 1.8 Well.ft. 34-0 bags 29.4 sq.ft 1.0881bs: R-13 3.50" 2'x 1D' 9.25' R-39 1.8lbsku,ft. 43.4 bags 29,1 sq.& 1.38816S. R-11 3.50' The higberasaRvakse.lnegmMeriheuwrtatrg pow. Toye nrematrdR-rahra.ittsessenbedtta:taatrriuta0ont>0.tnslaskaimpenY. R-8 '2.502.50 R-tauia55'canty ContomntoASTb1c6 rat Open Attic'Application,Bag Not Weight-Nominal 32lbs.,Minimum 31 Ills. apeof6bimHtf-iF 21F. Minimum Bags/ Maximum Minimum Initial Settled Framing Adjustment 1;000 SF Coverage Weight Installed Thickness" To compensate for framing members,the number of hags per The number of tugs/ Contents of this The weighM Thickness Contents of this 1,000 sq,It of area to be insulated should be as shown below R-Value* 1;goc Sf'of net area bag should net of installed Installed insulation bag should ss Ba siMSF Ba s1MSF To obtain an insulation should not be less cover insulation should not should not be la not cower more 9 B resistant o(R-Val on)cf. 'than: mom than: be leis than than: than Joist IS"O.G. 24"O.C. R-60 29.7 33.6 SF .952 lbs. 19.75t)' 19.750` R-Value Dimensions Framing Framing 2x4 29 2 29.4 R-49 23.5 42.5 SF .753lbs. 16,375' 16,375' R-60 2x6 28.9 29.1 R 44 20.9 47.8 SF t}lbs 67 . 14:875' 14.8757 2x8 28.6- 28.9 R-38 17.8 56.2 SF .569lbs. 13.00D' 13.000' 2x4 23.0 23.2 R-30 13.6 73.3 SF .437 Ibis. 10.375' 10.375' R49. 2x6 22.7 22.9' R-26 11.8 85.0 SF .377lbs. 9.126' 9.125' 2x8 22.4 227 R 22 .8 102.2 SF .313lbs. 7.750' 7.7507' 20 20A 2D,6 R-44 2x6. 20A 20.3 R-19 8.4 119.3 SF .266lbs. 6.750' 6.750' 2x8 19.8 20.1 R-13 5.7 175.3 SF A83 lbs. 4:750' 4.750' 2x4 17.3 . 17.4 R-11 4.7 210.8 SF .152 lbs. 4.000" 4,000' R_-38 W 17.D 17.2 ftrtvmo-nmu,dl=ft.ererm31ba 2x8 16.7 17.0 w�ared.meaeoeala.«eawmoaaartpett+.uraazte.�tceagnr.anlrg,aop�.gza>marse.alsadr►darr�na,rMr� Trapoaoo'br to G4WbasreMa*mtrtrdAMC15t,Tree 1,manooeed Ptdrtr SPtdrt7eo,rast•tOX%Trpe1,i]ss&WrAmso ttenrediswoounes nCWaid CSia. 2x4 13.2 113.3 4i oast nrsx abfwette.Troidpt�w*P+nam the prserLmiar/strgpoeer Tawet the m.tdR+de.Abessa331P�tJisi sY6ontehtitNtdp agtRY,Kpu doslosroa,getYr�uo- R•30 24 12.9 13.1' S°°'a'tw""u°ea4R,ietrutfamdpeRccne+�rdspar►aga 'Euedon ihed Palr2�xu teeYq ttdr,6a pander nf&rxMava I4yeat>e+iod aoeW G t peomlorkse.Tin trmutltl terinp a l'rnuh TMrelG0.Gahot�,dard aCad 2x8 12.6 12.9 +ro tlre� 20 1 11.3 11.4 R-26 24 11.0 11:2 Builder's Insulation Statement 2x8 10:8 11 0 Jet Stream Ulha has been Installed in con1drinance,with ft included recommendations to provide a thermal rasistanCe of... 2x4 9.3 9.&. R-Value Thickness R-22 2x6 9.1 9:3: Attic Area R 8t Inches 2x8 8.8 9.1 Sloped Ceilings R at inches 2x4 7. 8.1 Walls R- at Inches R•19 2x6 7.7 7.9' Floors Crawl.Space Pe er R-{over.an unheated crawl space) R- at Inches 2x8 7.4 7.7: " 2x4 -5.3 _. 5,4 at Inches R-13 2x6 5.0 _ 5:2 Date installed. _ 2x8 3.8 4.1 ,4.3 5.0 Bb sl afion has been insta ed in conformance with the above re d ns provide an R-value of: 2x4 4. - 4.4 R ,using bags of this Insulation"to cover f" square test of area R-11 2x6 4.1 4.3 2x$ at a minimum thickness of inches. ffi% cet,..yen,,.�, tnsntat»n Cortfrdctx{signaYtro) rsnta0u*tn odd'- r,.,,+M++rw wtLq-r bo.aMwd uu Company .d andarwd He=Buadw{sgnotomi CORWa^Y Date The coverage infeTTnatian on this AuidSidewalt card applies to the entire United States(including Minnesota). Knauf Insulation,Inc. One Knauf Drove,Shelbyville;IN 46176 Tel:(800)8254434 ext 8300 FAX.(317)39&3675 0 2015 Knauf insulation,inc. Lennar Homes-6600 Wagon Trail St-2,376 sq ft o umn ts SQ. FEET PRICE MAIN OR LIVING: 2,376 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 267,656.40 FEE SHEET $ 1,380.00 ADDRESS $ 30.00 DRIVEWAY $ 45.00 BUILDING: $ 1,482.60 ELECTRICAL: $ 310.50 PLUMBING: $ 207.00 MECHANICAL: $ 144.90 SUB-TOTAL $ 2,145.00 TOTAL $ 2,145.00 SEWER: n/a WATER: n/a IRRIGATION: $ - TOTAL: $ - WATER METER: n/a IRRIGATION METER F - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 2,698.35 PARK IMPACT FEES $ 769.56 SIF'S: $ 4,828.00 100.0% $ 4,828.00 1.0% $ 48.28 TOTAL: $ 4,876.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 11,976.19 1 Q� n P+ ti i 1'LD filmn :k n� City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: Oorle� _ � r Date Received: f ' Site: 0 Permit Type: fl Cf �- Approved w/no comments:❑ Approved w/the below comments:. Denied w/the below comments: ❑ This comment sheet shall be kept with the permit and/or plans. Kalvin Mitzer—Plans Examiner Date Contractor and/or Homeowner -� (Required when comments are present) 2018053286 Rept:1944465 IRec: 10.00 DS: 0.00 04/02/2018 K. A. , Dpty Clerk PAULA s.o'NE1L,Ph.D.PASCO CLERK & COMPTROLLER 04/02/201801 m 97 _P�224 .---- OR BK Permit No. Parcel ID No 05-26-21-0080-00600-0090 NOTICE OF COMMENCEMENT State of Florida County of Pasco THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement: 1. Description of Property: Legal SILVERADO RANCH SUBDIVISION PHASES 6,8&9A PB 75 PG 75 BLOCK 06 LOT 09 Street Address: 6600 Wagon Trail Street Zephryhills FL 33541 2. General Description of Improvement Single Family Residence/Pool/Screen Enclosure/Fence 3. Owner Information: Lennar Homes, LLC. Name 4600 W Cypress St, Ste 200 Tampa FL, 33607 Address City State Interest in Property: Name of Fee Simple Titleholder: N/A (If other than owner) Address City State 4. Contractor: Lennar Homes, LLC Name 4600 W Cypress St, Ste 200 Tampa FL, 33607 Address City State Contractor's Telephone No.: 813.574.5700 5. Surety:' .`r N/A Name Address_ City State Amount of Bond: $ Telephone No.: 6. Lender: N/A Name Address City State Lender's Telephone No.: 7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)(7),Florida Statutes: Lennar Homes LLC Name 4600 W Cypress St, Ste 200 Tampa FL, 33607 Address City State Telephone Number of Designated Person: 813.574.5700 8. In addition to himself,the owner designates N/A of to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statutes. Telephone Number of Person or Entity Designated by Owner: 9. Expiration date of Notice of Commencement is one year from the date of recording unless a different date is specified: WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. STATE OF FLORIDA COUNTY OF PINELLAS Signature of Owner or Owner's Authorized Officer/Director/Partner/Manager Vice President Signatory's Title/Office The foregoing instrument was acknowledged before me this 30 day of March by Steve Robert Smith as Vice President (type d rr y,e.g.,o r r,trustee,attorney in fact)for Lennar Homes LLC me of pa on bstrument was executed). Personally Known®OR Produced Identification❑ N o t a��Siia Type'of Identification Produced Name(Print) ElissgiTolleran Verification pursuant-to Section 92.525,Florida'Statutes.-Under penalties of perjury,I declare that I have read the foregoing and that the facts stated in it are true to the best of my,knowledge and belief.: . ELISSAM.;HOLLERAN Si ature of Natura Person Signing Above X Cemanlealon ailFF 885637 &PIres June 6,2020 m; " sondNThruTroyFolnlntunince100,1i5.701D TATE OF FLORibA,COUNTY OF PASCO THIS IS TO CERTIFY THAT THE FOREGOING:-,IS A TRUE AND CORRECT COPY OF THE DOCUMENT a, ON FILE OR OF PUBLIC RECORD IN THIS OFFICE WITNESS MY HAND AND OFFICIAL SEAL THIS In God We Trust DAY OF. ��°�,'� PAIU _S.O'NEIL,,CL R -&COMPTROLLER `�: gg�� DY 411 VI' o'k.", DEPUTY CLERK 41 'PASCO COUNTY, FLORIDA Permit No, !q 6 11 _ Date Permitted _q-2-1 Builder Name/Owner Name kQAt,tl6in' pw�o Ua Control#' County Parcel No.Address/Location t�tJ D`U�a-�DC��Ol3IY��Su—b-Div: t tJ�YG�G(Z) �D i G i Classification/Type of Use C> TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: 2 8710 Exempt ❑Yes ❑ No f How Determined Impact Fee Amount,(t Zone No. TAZ: SCHOOL IMPACT FEE Account (056) Single-Family Detached House Amount $ _ / t Z�• D(� (057) Mobile Home (056) Other Residential 23) Collection Fee Exempt d Yes ❑ No How Determined PARKS AND RECREATION FEE Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation Total Zone TOTAL AMOUNT $. +'�• c'rj,�, Exempt ❑Yes ❑ No How Determined LIBRARY FEE Land Account Land Credit Land Total Facility Account Fac!!!ty Credit Facility Total J Exempt ❑Yes ❑ No How Determined Total Amount �---�" RESOURCE FEE ERU j TOTAL AMOUNT Prepared By Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY Acknowledgement below does not imply acceptance of concurrence,but simply receipt of a copy of this form,placing . the building permit owner on notice of this assessment and the conditions of payment for same. DATE RECEIVED BY RECEIPT NO. DATE BY 05-26-21-0080-00600-0090.1 Pasco County Property Appraiser Page 1 of 1 . Data Current as Of: Weekly Archive - Saturday, March 24, 2018 Parcel ID 05-26-21-0080-00600-0090 (Card: 001 of 001) Classification 00 - Vacant Residential Mailing Address Property Value LENNAR HOMES LLC Ag Land $0 4600 W CYPRESS ST STE 200 Land $2;481 TAMPA FL 33607-4099 Building $0 Physical Address Extra Features $0 6600 WAGON TRAIL STREET ZEPHYRHILLS, FL 33541 $2,481 Just Value Legal Description (First 4 Lines) Assessed (Non-School Amendment 1) $2,481 SILVERADO RANCH SUBDIVISION PHASES 6, 8 &9A PB 75 PG 075 BLOCK 6 Taxable Value $2,481 LOT 9 Jurisdiction City of Zephyrhills Land Detail (Card: 001 of 001) Line _ Use _ _EDescription,Zo_ning Units Type Orice '--Condition Value_ w1 � 0100_ SFR �` MPUD— 6,000.00 SF j $0.40 1.00 —j $2,400 i 2� 0100 SFR �`MPUD 325.00 SF �j $0.25 j 1.00 j $81 Additional Lan_d Information Acres —0.15 Tax Area 30SI TResidential Code SLVRCPI i I Code Building Information - Use 00 - Unimproved (Card: 001 of 001) Unimproved Parcel 00 - Unimproved Extra Features (Card: 001 of 001) _ Line_ �Descnption __jYear _Units Value No Extra Features Sales History - See All 6 sales Previous Owner: DUNE FL LAND I SUB LLC Month/Year(Book/Page ~_�Type^ _ DOR Code ConditionjAmount 03/2018�9694 / 3124__1—_ Warranty Deed _ _ 05 Vacant Multi-Parcel Sale 05/2017 !9535 / 0546 � Certificate of Title i 05 Vacant ,Multi-Parcel Sale 11/2016 19462 / 0384 Mineral Rights or Royalty Transfer 05 Vacant Multi-Parcel Sale i http://search.pascopa.com/parcel.aspx?parcel=2126050080006000090 .. 4/2/2018 Lennar Homes-6600 Wagon Trail St-2.376 sq ft Column ts SQ. FEET PRICE MAIN OR LIVING: 2,376 $ 106.36 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 252,711.36 FEE SHEET $ 1,305.00 ADDRESS $ 40.00 DRIVEWAY $ 40.00 BUILDING: $ 1,411.10 ELECTRICAL: $ 293.63 PLUMBING: $ 195.75 MECHANICAL: $ 137.03 SUB-TOTAL $ 2,037.50 TOTAL $ 2,037.50 SEWER: n/a WATER: n/a IRRIGATION: $ - TOTAL: $ - WATER METER: n/a IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 2,590.85 PARK IMPACT FEES $ 769.56 SIF'S: $ 7,128.00 100.0% $ 7,128.00 1.0% $ 71.28 TOTAL: $ 7,199.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 14,191.69 - 813-780-0020 Cdvof�eohvrhi\|oP�[nl�4op\k��t�O Fu»» @�»»�0� .� __,..'... Application- | ' . Building Department Date Received Phone Contact for Permitting 363 2891 Owners Name Owner Phone Number Owner's Address 4600 ress FL 33607 Owner p hone Number Fee Simple Titleholder Name Owner Phone Number- Fee Simple Titleholder Add xoaxoo��amil ��'* 10090 auoo|wS|om Silverado Ranch Subdivision Ph 2,3,&4vAmnEL|o# 05-26-21-0080-00600-0090 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW comsrx ADD6«LT [---1 S|GN �--1 �—� DEMOLISH P INSTALL [_] REPAIR PROPOSED USE opn F-� COMM [---1 oTHen TYPE opCONSTRUCTION ouo�K �—} �n�m� [---1 oTs�� oo�v ^—� `---^ �—� DESCRIPTION oFWORK Single Family Residence Pool/Screen Enclosure/Fence BUILDING SIZE So FOOTAGE L���� J HEIGHT |uU|uo|NG VALUATION OF TOTAL CONSTRUCTION �-_�s�soT�|��� ��-� PPoons��smsR�v [-� vvn�� �� V �^�_. � � . � �-� AMP SERVICE �� UpLuma/wo ���� MECHANICAL VALUATION OF MECHANICAL INSTALLATION ' [` ��� � =Gxa nonRmo F—1 SPECIALTY OTHER oT*ER R �� Do FLOOD DYES o � � | |` ou|Lose SIGNATURE REGISTERED Y/_x ] Fssouunsx Address 20 Ucenua# sLeoTno|xm COMPANY Edmonson Electric, Inc. SIGNATURE REGISTERED Y/_N_] pcsuunnsN L_Y2N_] Aduomoa 11034 Skipper Road,Tampa, FL 33613 Ucenon# PLUMBER COMPANY 113ayonet PIUMbing, Heating &AC, Inc SIGNATURE REGISTERED Y/ N ] pssounnsx L_L��_] Address License# MEoxxm|oAL COMPANY [��ayonet PIUMbing, Heating &AC, Inc SIGNATURE REGISTERED Y/ NJ pssouensx L_2L/_� Address ucenoo# OTHER COMPANY I SIGNATURE REGISTERED [_Y/ N_] FEEoumnsN LILN__J Address 14211 Shoal Line Blvd, SpAg Hill, FL 346 Licanne# RESIDENTIAL Attach V4 Plot Plans;(2)uom of Building Plans;(1)oo$of Energy runna;R.O-W Permit for new construction, Minimum ten(1O)working days after submittal date. Required unuUe.Construction Plans,Gmnnwoter Plans v/Slit Fence installed, Sanitary Facilities&1dumputer;Site Work Permit for subdivisions/large projects COMMERCIAL Auuoo(2)complete sets of Building Plans plus e Life Safety Page;(1)set of Energy Forms.R.O4w Permit for new construction. Minimum ten(1V)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Slit Fence installed, Sanitary Facilities m1dumpxter.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach;4 sets m(Engineered Plans. "=PROPsRTY SURVEY required for all NEW construction. Fill out application completely. Owner&Contractor sign back of application,notarized n over$csmo,a Notice ur Commencement isrequired. (Ao upgrades over$7oun) ^° Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy o[contract required) Remofs if shingles Sewers Service Upgrades A/C Fannou(P|uUSuwey/FumtaAo) Driveways-Not over Counter if on public roadways..needs nOVV NOTICE OF DEED : The undersigned understands that this permit may ba subject to^deed^ restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with oriy applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by |avv, both the owner and contractor may be cited for misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contnyotone, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contnautor, that may boan indication that he1a not properly licensed and is not entitled topermitting privileges in Pasco County. TRANSPORTATION I88PA0T/UTILITTESI0|PACT AND RESOURCE RECOVERY FEES: The undersigned understands thatTranoportoUonImpaotFaee-ondRecnuroeRecoveryFeeamayapplytmtheoonotructinnofnmwbuUd)ngo. chongeof use in existing buildings, or expansion of existing bui|dingo, as specified in Pasco County Ordinance number80-07 and 90'07. as amended. The undersigned also understands, that such feeo, as may be due, will be identified sd the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving o "certificate of occupancy" or final power release. |f the project doamnotinvokeaoartifineteofocoupanuyor final power release, the fees 0Uot be paid prior to permit issuance. Furthermore, if Pasco CoVntvVVater/8ewe[ Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, omomnended): |f valuation of work io $2.5OO.DOormore, | certify that |, the appUoont, have been provided with a copy of the "Florida Construction Lion Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consu.mer Affairs. If the applicant iasomeone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver itho the°mwnar"prior hocommencement. C0NTRACTOR'S/OVVNER'S &FF|DAVlT: | certify that all the information in this application is accurate and that all work will be done in compliance with all applicable |mms regulating construction, zoning and land development. Application is hereby made to obtain o permit to do work and installation as indicated. i certify that no work or inmtaUotion has commenced prior to issuance of a permit and that all work will be performed to meet standards of all |ewo regulating construction, County and City codes, zoning neDu\cdionm, and land development regulations in the jurisdiction. | also certify that | understand that the regulations of other government agencies may apply to the intended vvnrh, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department ofEnvironmental Protection-Cypress Bayheeda. Wetland Areas and Environmentally Sensitive Lando. VVater88aetewoterTnaatmont. - Southwest Florida VVsder Management Oisthot-VVeUe' Cypress Boyheado, Wetland Anaeo, Altering Watercourses. - Army Corps 0fEngiOeem'8eawaUn. Docks, Navigable Waterways. - Deportment of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - UG Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runvveyo. > understand that the following restrictions apply to the use offill: - Use of fill io not allowed in Flood Zone"V" unless expressly permitted. - If the fill material is to be used in Hood Zone "/Y', it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the StoteofFlorida, - |f the fill material is to be used in Flood Zone "A" in connection with m permitted building using stem xvoU construction, I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, | certify that use of such 5U will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots |ena than one (1) acre which are elevated bv fill, an engineered drainage plan iarequired. |f| om the AGENT P0�� OWN ER, this affidavit prior to commencing construction. | understand that o separate permit may be required for electrical work, p|umb)ng, signs, weKa, poolm, air conditioning, goo, or other installations not specifically included in the application. A permit issued ahoU be construed.to be license to proceed with the work and not as authority toviolate, nanco|, alter, or set aside any provisions of the.technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension may be nequeoted, in vvriUng, fnom the Building Official for o period not to exceed ninety (80) days and will demonstrate 'uotUiob\ecause for the emdannion. |f work ceases for ninety(8O) consecutive days,the job ia considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COK8K0E0CEK8G0T MAY RESULT IN YOUR INTENDPAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COAMENCEMENT. OWNER OR AGENT CONTRACTOR Subscribed and swor�to�(orafflra�dd)liefore m this Subscribed and sworn to(or affirme96 re me this WEo is/are personally known to me or I iasihave PF9dWGe Who istare personally known to me or .--predue-ed- _--,as identification. Notary Public Notary Public Commission BliosaM.Holleran 8lisouM.Holleran FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 1941A1 sf ADS Builder Name: Lennar Homes Street: 6600 Wagon Trail Street Permit office: City of Zephyrhills City,State,Zip: Zephyrhills,FL, Permit Number: j $ j� Owner. Lennar Homes Jurisdiction:611600 Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1961.3 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1454.60 ft2 b.Frame-Wood,Adjacent R=11.0 506.78 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (1936.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1936.00 ft2 6. Conditioned floor area above grade(ft2) 1936 b.NIA R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(157.3 sqft.) Description Area a.Sup:Attic,Ret:family rm,AH:laundry rm 6 387.2 a. U-Factor: Dbl,U=0.54 101.00 ft2 SHGC: SHGC=0.31 b. U-Factor. Dbl,U=0.56 33.33 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 34.2 SEER:15.00 c. U-Factor: Dbl,U=0.56 23.00 ft2 SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 32.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 1.212 ft. Area Weighted Average SHGC: 0.308 14.Hot water systems 8. Floor Types (1936.0 sqft.) Insulation Area a.Electric Cap:40 gallonsEF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ft2 b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.081 Total Proposed Modified Loads: 62.58 PASS Total Baseline Loads: 62.81 hereby certify that the plans and specifications covered by Review of the plans andT -ST.q?.. �._�this calculation are in compliance with the Florida Energy specifications covered by this Q ;.�`�© . •. ' Code. calculation indicates compliancer;..: A/�,,�/I' /,,I with the Florida Energy Code. �. m„ `% °.�. „ O ttW PREPARED BY: Davy �ll h Before construction is completed DATE: this buildingwill be inspected for P t➢.��Cl �: compliance with Section 553.908 I herebycertify that this building,as designed,Zr-Bco ' m liance Florida Statutes. fY 9 9P !jr - with the Florida Energy Code. coy, OWNER/AGENT: CHECKED 0 BUILDING OF IC A_� DATE: DATE: - Compliance requires certification by the air andler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 6.50 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.030 Qn for whole house. 2/1/2018 7:42 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 6 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 1941A1 sf ADS Builder Name: Lennar Homes Street: 6600 Wagon Trail Street Permit office: City of Zephyrhills City,State,Zip: Zephyrhills,FL, Permit Number: Owner: Lennar Homes .jurisdiction:611600 Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1961.3 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1454.60 ft2 b.Frame-Wood,Adjacent R=11.0 506.78 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 10.Ceiling Types (1936.0 sqft.) Insulation Area 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1936.00 ft2 6. Conditioned floor area above grade(ft2) 1936 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(157.3 sqft.) Description Area a.Sup:Attic,Ret:family rm,AH:laundry rm 6 387.2 a. U-Factor: Dbl,U=0.54 101.00 ft2 SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.56 33.33 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 34.2 SEER:15.00 c. U-Factor: Dbl, U=0.56 23.00 ft2 SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 32.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 1.212 ft. Area Weighted Average SHGC: 0.308 14.Hot water systems 8. Floor Types (1936.0 sqft.) Insulation Area a.Electric Cap:40 gallons EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ft2 b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.081 Total Proposed Modified Loads: 62.58 PASS Total Baseline Loads: 62.81 I hereby certify that the'plans and specifications covered by Review of the plans andT_k 'STT, this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: 'pave Aupich Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 *, / hereby certify that this building,as designed, is in compliance Florida Statutes. with the Florida Energy Code. OWNER/AGENT: BUILDING OFFI IAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 6.50 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSIIRESNETIICC 380, is not greater than 0.030 Qn for whole house. 2/1/2018 7:42 AM EnergyGaugeO USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 6 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 1941A1 sf ADS Builder Name: Lennar Homes Street: 6600 Wagon Trail Street Permit Office: City of Zephyrhills City,State,Zip: Zephyrhills,FL, Permit Number: Owner: Lennar Homes Jurisdiction:611600 Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1961.3 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1454.60 ftz b.Frame-Wood,Adjacent R=11.0 506.78 ftZ 3. Number of units,if multiple family 1 c.N/A R= ftz 4. Number of Bedrooms 4 d.N/A R= ftz 5. Is this a worst case? Yes 10.Ceiling Types (1936.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1936.00 ftz 6. Conditioned floor area above grade(ftz) 1936 b.N/A R= ft2 Conditioned floor area below grade(ftZ) 0 c.N/A R= ftz. 11.Ducts R ftZ 7. Windows(157.3 sqft.). Description Area a.Sup:Attic,Ret:family rm,AH:laundry rm 6 387.2 a. U-Factor: Dbl,U=0.54 101.00 ftZ SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.56 33.33 ftZ 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 34.2 SEER:15.00 c. U-Factor. Dbl,U=0.56 23.00 ftZ SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ftZ a.Electric Heat Pump 32.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 1.212 ft. Area Weighted Average SHGC: 0.308 14.Hot water systems 8. Floor Types (1936.0 sqft.) Insulation Area a.Electric Cap:40 gallonsEF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ftZ b. Conservation features b.N/A R= ftZ None c.N/A R= ftZ 15.Credits Pstat Glass/Floor Area: 0.081 Total Proposed Modified Loads: 62.58 PASS Total Baseline Loads: 62.81 hereby certify that the plans and specifications covered by Review of the plans and . this calculation are in compliance with the Florida Energy specifications covered by this f.` Code. calculation indicates compliance c,,'i'�;;, '' `-'s �•�� �+ `/�/� /� with the Florida Energy Code. PREPARED BY: J,)aypl ACol;ich Before construction is completed DATE: this buildingwill be inspected for ,C P C7. �ll; � X _ compliance with Section 553.908 I herebycertify that this building,as designed,is in compliance Florida Statutes. fY 9. 9 P ? with the Florida Energy Code. COp y`r :I OWNER/AGENT: BUILDING OFFIC L: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 6.50 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.030 Qn for whole house. 2/1/2018 7:42 AM EnergyGaugeO USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 6 , S FORM R405-2017 PROJECT Title: 1941A1 sf ADS Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 1936. Lot# Owner Name: Lennar Homes Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: Lennar Homes Rotate Angle: 45 Street: Permit Office: Cross Ventilation: No County: Pasco Jurisdiction: Whole House Fan: No City,State,Zip: Zephyrhills, Family Type: Single-family FL, New/Existing: New(From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Tampa FL TAMPA_INTERNATI 39 91 70 75 645.5 54 Medium BLOCKS Number Name Area Volume 1 Entire House 1936 16360.3 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 master 210 1680 No 2 1 1 Yes Yes Yes 2 family rm 341 3171.3 No 0 1 Yes Yes Yes 3 cafe 161 1288 No 0 1 Yes Yes Yes 4 kit 182 1692.6 Yes 0 1 Yes Yes Yes 5 bdrm2 147 1176 No 1 1 1 Yes Yes Yes 6 bdrm3 149 1192 No 1 1 1 Yes Yes Yes 7 bath2 61 488 No 0 1 Yes Yes Yes 8 bdrm4 149 1192 No 1 1 1 Yes Yes Yes 9 o wic 104 832 No 0 1 Yes Yes Yes 10 privy 24 192 No 0 1 Yes Yes Yes 11 o bath 117 936 No 0 1 Yes Yes Yes 12 laundry rm 100 800 No 0 1 Yes Yes Yes 13 foyer 148 1376.4 No 0 1 Yes Yes Yes 14 hall 43 344 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet j 1 Slab-On-Grade Edge Insulatio master 29.5 ft 0 212.3 ft2 ____ 0 0 1 2 Slab-On-Grade Edge Insulatio family rm 14.5 ft 0 340.8 ft2 0 0 1 3 Slab-On-Grade Edge Insulatio cafe 25.5 ft 0 161 ft2 0 0 1 4 Slab-On-Grade Edge Insulatio kit 13.5 ft 0 182.3 ft2 1 0 0 2/1/2018 7:42 AM EnergyGaugeO USA-FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 6 1 FORM R405-2017 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 5 Slab-On-Grade Edge Insulatio bdrm2 10.5 ft 0 146.8 ft2 0 0 1 6 Slab-On-Grade Edge Insulatio bdrm3 13.5 ft 0 148.5 ft2 -- 0 0 1 7 Slab-On-Grade Edge Insulatio bath2 5.5 ft 0 60.5 ft2 1 0 0 8 Slab-On-Grade Edge Insulatio bdrm4 35.5 ft 0 148.5 ft2 0 0 1 9 Slab-On-Grade Edge Insulatio o wic 21 ft 0 104 ft2 —� 0 0 1 10SIab-On-Grade Edge Insulatio privy 1 ft 0 24 ft2 1 0 0 11Slab-On-Grade Edge Insulatio o bath 10.5 ft 0 117.3 ft2 1 0 0 12Slab-On-Grade Edge Insulatio laundry rm 9 ft 0 100 ft2 —� 1 0 0 13SIab-On-Grade Edge Insulatio foyer 22.5 ft 0 147.5 ft2 1 0 0 14SIab-On-Grade Edge Insulatio hall 2 ft 0 42.5 ft2 0 0 1 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 2097 ft2 0 ft2 Medium 0.85 No 0.9 No 0 22.6 / ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 1936 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) master 30 Blown 210 ft2 0.1 Wood 2 Under Attic(Vented) family rm 30 Blown 341 ft2 0.1 Wood 3 Under Attic(Vented) cafe 30 Blown 161 ft2 0.1 Wood 4 Under Attic(Vented) kit 30 Blown 182 ft2 0.1 Wood 5 Under Attic(Vented) bdrm2 30 Blown 147 ft2 0.1 Wood 6 Under Attic(Vented) bdrm3 30 Blown 149 ft2 0.1 Wood 7 Under Attic(Vented) bath2 30 Blown 61 ft2 0.1 Wood I 8 Under Attic(Vented) bdrm4 30 Blown 149 ft2 0.1 Wood 9 Under Attic(Vented) o wic 30 Blown 104 ft2 0.1 Wood 10 Under Attic(Vented) privy 30 Blown 24 ft2 0.1 Wood 11 Under Attic(Vented) o bath 30 Blown 117 ft2 0.1 Wood 12 Under Attic(Vented) laundry rm 30 Blown 100 ft2 0.1 Wood 13 Under Attic(Vented) foyer 30 Blown 148 ft2 0.1 Wood 14 Under Attic(Vented) hall 30 Blown 43 ft2 0.1 Wood 2/1/2018 7:42 AM EnergyGaugeO USA-FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 6 FORM R405-2017 WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 S=>SW Exterior Concrete Block-Int Insul master 4.1 12 6 8 0 100.0 ft2 0 0 0.6 0 2 W=>NW Exterior Concrete Block-Int Insul master 4.1 17 0 8 0 136.0 ft2 0 0 0.6 0 _ 3 S=>SW Exterior Concrete Block-Int Insul family rm 4.1 14 6 9 4 135.3 ft2 0 0 0.6 0 4 E=>SE Exterior Concrete Block-Int Insul cafe 4.1 12 0 8 0 96.0 ft2 0 0 0.6 0 5 S=>SW Exterior Concrete Block-Int Insul cafe 4.1 13 6 8 0 108.0 ft2 0 0 0.6 0 6 E=>SE Exterior Concrete Block-Int Insul kit 4.1 13 6 9 4 126.0 ft2 0 0 0.6 0 7 E=>SE Exterior Concrete Block-Int Insul bdrm2 4.1 10 6 8 0 84.0 ft2 0 0 0.6 0 8 E=>SE Exterior Concrete Block-Int Insul bdrm3 4.1 13 6 8 0 108.0 ft2 0 0 0.6 0 9 E=>SE Exterior Concrete Block-Int Insul bath2 4.1 5 6 8 0 44.0 ft2 0 0 0.6 0 10 N=>NE Exterior Concrete Block-Int Insul bdrm4 4.1 13 6 8 0 108.0 ft2 0 0 0.6 0 11 E=>SE Exterior Concrete Block-Int Insul bdrm4 4.1 11 0 8 0 88.0 ft2 0 0 0.6 0 12 W=>NW Exterior Concrete Block-Int Insul bdrm4 4.1 11 0 8 0 88.0 ft2 0 0 0.6 0 _13 N=>NE Garage Frame-Wood o wic 11 28 4 8 0 226.7 ft2 0 0.25 0.01 0 14 W=>NW Exterior Concrete Block-Int Insul o wic 4.1 8 0 8 0 64.0 ft2 0 0 0.6 0 15 W=>NW Exterior Concrete Block-Int Insul o bath 4.1 10 6 8 0 84.0 ft2 0 0 0.6 0 _16 N=>NE Garage Frame-"Wood laundry rm 11 17 5 8 0 139.3 ft2 0 0.25 0.01 0 17 N=>NE Exterior Concrete Block-Int Insul foyer 4.1 5 0 9 4 46.7 ft2 0 0 0.6 0 _18 W=>NW Garage Frame-Wood foyer 11 15 1 9 4 140.8 ft2 0 0.25 0.01 0 19 W=>NW Exterior Concrete Block-Int Insul foyer 4.1 2 5 9 4 22.6 ft2 0 0 0.6 0 20 W=>NW Exterior Concrete Block-Int Insul hall 4.1 2 0 8 0 16.0 ft2 0 0 0.6 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N=>NE Wood laundry rm None .4 2 8 6 8 17.8 ft2 2 N=>NE Insulated foyer None .2 3 6 8 20 ft2 WINDOWS Orientation shown is the entered orientation =>)changed to Worst Case. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 S=>SW 1 Metal Low-E Double Yes 0.54 0.31 N 23.0 ft2 1 ft 0 in 0 ft 10 in None None 2 S=>SW 3 Metal Low-E Double Yes 0.54 0.31 N 46.0 ft2 1 ft 0 in 0 ft 10 in None None 3 S=>SW 5 Metal Low-E Double Yes 0.56 0.32 N 33.3 ft2 2 ft 0 in 0 ft 4 in None None I 4 E=>SE 7 Metal Low-E Double Yes 0.54 0.31 N 16.0 ft2 1 ft 0 in 0 ft 10 in None None 5 E=>SE 8 Metal Low-E Double Yes 0.54 0.31 N 16.0 ft2 1 ft 0 in 0 ft 10 in None None 6 N=>NE 10 Metal Low-E Double Yes 0.56 0.28 N 23.0 ft2 1 ft 0 in 4 ft 0 in -None None 2/1/2018 7:42 AM EnergyGaugeO USA-FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 6 FORM R405-2017 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 416ft2 416ft2 43.7ft 8ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000349 1772.4 97.3 182.99 .2618 6.5 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 32.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 34.2 kBtu/hr 1026 cfrn 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 40 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ftz DUCTS —Supply— —Return— Air CFM 25 CFM25 HVAC# # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 387.2 ft family rm 96.8 ft2 Proposed Qn laundry rm —cfm 58.1 cfm 0.03 0.50 1 1 2/1/2018 7:42 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 6 FORM R405r2017 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Cooling � ]]Jan Feb Mar A r I j Ma Jun Jul rj Au ri Se [ Oct [ ]Nov Dec Heatin [X]Jan Feb f X�Mar E Apr May Jun Jul Au Sep [ ]Oct [X]Nov Dec Ventin [[ ]]Jan Feb [X Mar [X A r May Jun Jul Aug Se [X]Oct [X]Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 2/1/2018 7:42 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 6 of 6 FORM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerformance Index, the more efficient the home. Zephyrhills, FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1454.60 ft2 b.Frame-Wood,Adjacent R=11.0 506.78 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 10.Ceiling Types Insulation Area 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1936.00 ft2 6. Conditioned floor area(ft2) 1936 b.N/A R= ft2 7. Windows" Description Area c.N/A R= ft2 a. U-Factor: Dbl,U=0.54 101.00 ft2 11.Ducts R ft2 SHGC: SHGC=0.31 a.Sup:Attic,Ret:family rm,AH:laundry rm 6 387.2 'b. U-Factor: Dbl,U=0.56 33.33 ft2 SHGC: SHGC=0.32 12.Cooling systems kBtu/hr Efficiency c. U-Factor. Dbl,U=0.56 23.00 ft2 a.Central Unit 34.2 SEER:15.00 SHGC: SHGC=0.28 d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 32.8 HSPF:8.50 Area Weighted Average Overhang Depth: 1.212 ft. Area Weighted Average SHGC: 0.308 8. Floor Types Insulation Area 14.Hot water systems a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ft2 EF:0.95 b.N/A R= ft2 c.N/A R= ft2 b. Conservation features None 15.Credits Pstat certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed `,.'o, based on installed Code compliant features. " �r % -:;r Builder Signature: Date: 02/01/18 Address of New Home: 6600 Wagon Trail Street City/FL Zip: Zephyrhills, Off' wE i *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 2/1/2018 7:43 AM EnergyGauge@ USA-FlaRes2017 -Section R405.4.1 Compliant Software Page 1 of 1 Building Analysis Job: 1941A1 sf ADS g Y Date: 21112018 Entire House By: Dave Bayonet Plumbing Heating and Air Project Information For: Lennar Homes Design Conditions Location: Indoor: Heating Cooling Tampa International AP, FL, US Indoor temperature(°F) 70 75 Elevation: 10 ft Design TD (°F) 39 16 Latitude: 280N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 34.7 54.7 Dry bulb(°F) 31 91 Infiltration: Daily range(°F) - 14 ( L ) Method Simplified Wet bulb(°F) - 77 Construction quality Semi-tight Wind speed(mph) 15.0 7.5 Fireplaces 0 o • Component Btuh/ftz Btuh /° of load Walls 5.6 7036 24.6 °� Glazing 30.2 4709 16.5 Wall Doors 23.5 466 1.6 nfiltration Ceilings 1.3 2429 8.5 Floors 3.5 6726 23.5 Infiltration 2.8 3996 14.0 Ducts 3223 11.3 Piping 0 0 Glazing Humidification 0 0 Floors Other Ventilation 0 0 Ceilings Adjustments 0 Total 28584 100.0 Component Btuh/ft2 Btuh % of load . Walls 2.8 3600 13.4 Walls Glazing 56.7 8852 34.0 Internal Gains Doors 18.4 365 1.4 Ceilings 1.7 3358 12.9 Floors 0 0 0 Infiltration 0.6 880 3.4 Ducts 3621 13.9 Ducts Ventilation 0 0 Glazing Internal gains 5455 21.0 Blower 0 0 . Infiltration Adjustments 0 Total 26030 100.0 Other Ceilings Latent Cooling Load=4171 Btuh Overall U-value= 0.103 Btuh/ftz-°F Data entries checked. t + wrightsoft® 2018-Feb-01 07:29:57 CAMRight-Suite®Universal 2017 17.0.23 RSU05714 Page 1 ...ith CBA27UHE AH's11941 sfADS template,3ton.rup Calc=MJ8 Front Door faces: W Project Summary Job: 1941A1 sf ADS Pro J •7 Date: 2/1/2018 Entire House By: Dave Bayonet Plumbing Heating and Air Project Information For: Lennar Homes Notes: 2017 Designinformation Weather: Tampa International AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 31 OF Outside db 91 OF Inside db 70 OF Inside db 75 OF Design TD 39 OF Design TD 16 OF Daily range L Relative humidity 50 % Moisture difference 55 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 25361 Btuh Structure 22409 Btuh Ducts 3223 Btuh Ducts 3621 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh none (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 28584 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 26030 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 3525 Btuh Ducts 646 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling (none) Volume Area e(ft') 1936 1936 Equipment latent load 4171 Btuh 16360 16360 Air changes/hour 0.34 0.18 Equipment Total Load (Sen+Lat) 30201 Btuh Equiv.AVF (cfm) 93 49 Req. total capacity at 0.85 SHR 2.6 ton Heating Equipment Summary Cooling Equipment Summary Make Lennox Make Lennox j Trade 14HPX SERIES Trade 14HPX SERIES Model 14HPX-036-230-21 Cond 14HPX-036-230-21 j AHRI ref 10258589 Coil CBA27UHE-036-230*++TDR AHRI ref 10258589 Efficiency 8.5 HSPF Efficiency 12.5 EER, 15 SEER Heating input Sensible cooling. 29580 Btuh Heating output 32800 Btuh @ 47°F Latent cooling 5220 Btuh Temperature rise 25 OF Total cooling 34800 Btuh Actual air flow 1200 cfm Actual air flow 1200 cfm Air flow factor 0.042 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.86 Capacity balance point=29 OF Backup: n/a n/a Input= 0 kW, Output= 0 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. �- - 1- wrightsoftm Right-Suite®Universal 2017 17.0.23 RSU05714 2018-Feb-01 07:29:57 Page 1 �� ...ith CBA27UHE AH's%1941 sf ADS template 3ton.rup Calc=MJ8 Front Door faces: W Manual S Compliance Report Job: 1941A1 sf ADS Date: 211/2018 Entire House By: Dave Bayonet Plumbing Heating and Air Project Information For: Lennar Homes Cooling Equipment Design Conditions Outdoor design DB: 91.3°F Sensible gain: 26030 Btuh Entering coil DB: 75.6°F Outdoor design WB: 77.3°F Latent gain: 4171 Btuh Entering coil WB: 62.8°F Indoor design DB: 75.0°F Total gain: 30201 Btuh Indoor RH: 50% Estimated airflow: 1200 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: SpIitASHP Manufacturer: Lennox Model: 14HPX-036-230-21+CBA27UHE-036-230*++TDR Actual airflow: 1200 cfm Sensible capacity: 29070 Btuh 112% of load Latent capacity: 5130 Btuh 123% of load Total capacity: 34200 Btuh 113% of load SHR: 85% Heating Equipment Design Conditions Outdoor design DB: 30.8°F Heat loss: 28584 Btuh Entering coil DB: 69XF Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: SpIitASHP Manufacturer: Lennox Model: 14HPX-036-230-21+CBA27UHE-036-230*++TDR Actual airflow: 1200 cfm Output capacity: 32800 Btuh 115% of load Capacity balance: 29 OF Supplemental heat required: 0 Btuh Economic balance: -99 OF Backup equipment type: Elec strip Manufacturer: n/a Model: n/a+n/a Actual airflow: 1200 cfm Output capacity: 0 kW 0% of load Temp. rise: 0 OF Meets are all requirements of ACCA Manual S. wri htsoft' 2018-Feb-01 07:29:57 9 Right-Suited Universal 2017 17.0.23 RSU05714 Page 1 �'� ...Ith CBA27UHE AH's\1941 sf ADS template 3ton.rup Calc=MJ8 Front Door faces: W Single Family Dwel rig . . P lap Review_Comments: I F.F.E. slialI be a minimum of.8" above.the road elevation and an engineered site plan. 2.. Lots shall be graded.to.comply with R401.3 of theF.B.C. 3.: ,Compaetion:test required if 24" or more:of fill dirt is brought in-At anyone place: 4: Tie in survey required before pouring concrete.. _ 5.1 Driveways-require a'R.O.:W. use permit:- All 4 sides of driveway.thru the sidewalk shall have expansion material:. 6. All, setbacks.shall be met.: 7.: ;All.property markers shall be uricovereci and marked at time of first.'inspection: 8:. :All A.D.A:requirements shall be met. 9. No.electric;plumbing,mechanical;.or framing shall be covered without an:inspection and approval first. .. 10. All Garages shall-comply..with:section R302.6.of the:F.B.C.:.(Fire Separation).: 11.Appliances:shall not:be installed in a location where subject to,mechanical damage unless protected:by approved barriers. M303.4 of.the F.B:C. 12. Water heaters sh,all comply:with section P607,3 of the F.B.C. 13. Foundation supports for.A/C.units.shall be raisedat least 37 above finished grade., M1308.1 14. Return air in all bedrooins..F:B.C. .M1620.4-: 15. Smoke detectors are to be'installed n accordance:with R3111 oftheB.B.C. 16.: All glazing requirements are.to be in accordance with R308.4-of the.F.B.C. 17. All means,of egress are to:be in accordance with R311::of the F.B.C. . 18. `.`Green gypsum board shallriot be used as.a backer-in:showers or tubs. R702.4:2 F.B.C. . 19. Combination-type AFCI breakers are.required:at all,locations requiring an AFCLtype breaker: 20. Carbon monoxide.alarms will be required in-new construction that uses fossil-burning heating :or appliances or an attached garage: .They shall be.installed in accordance with,the F.B.C:_ : 21. A11 plumbing,mechanical,.and_electrical shall-be sepatate from unit.to unit: This includes all, underground plurribing and electric. 22. All 2011:N.E.C: Codes will be enforced: 23:Tamper-Resistant Receptacles in accordance with 406.11 of the 2011 N:E:C 24::In accordance with the Land:Development:Code; lots.shall be.sodded before final at least 10 feet:around the structure: 25. A.copy of the enerw-cacls shall be with:pern:itat all times. 26. Copy of final.insulation report shall be-provided with.permit.before.final F:F:E.-Finished Floor Elevation F.B.C=Florida Building Code 6a'Edition R.O..W.-Right.of Way.. A.D.A.-Americans with.-Disabilities Act N.E.C.-National Electric Code(2011) TYPE` D.••LANDSCA :. ,. t ''TYPE :LOT 7, �k , . I PAD=1.1'3.2 . ° , 1 , ,TYPt B 1 , 1^0 1 , .. i - i � t '•+1 •t :.�.,• .ice � •li i :i. FF=113.60 LAST 33•. AD=112.9 ��+ 1' ' , 1 `.Wf••1 +1 r .r' • , i` E' —1.13 10 f.,. 1 O'I,VJIs !.F ��. .��y0' TYPE A ,'�� II,V ' . :`' :.LOT' 8. y5; 1 ,.•' ti ;� I ::PAQ=1.1.2.4 1 ''.TYPE B + i • ;. z - -� I �%. •• 1 -1 LOT 1 1 _ 7 , .; ;� :_ �;� -r-`° I . ,, , r PAD W12.1 ,y t'2 30 �. � � 1 '�,. ,. r TYPE A. A. 106' ,' 1 .1 F`-'•.1 12,20 I 1 °� / 1,• 1 1 1.0. LOT 31 �'AjNAGE:EASEMENT•._ (o PAD=1�11.5 o TYPt A , .F`F=1.,1 601, �o o� ;. 1OA 0,1 ..""TYPE B �-.. . FF=1'11•.50 1 5 e� 1 a .LOT 30; ��' �° t 1 o �,� :'STRC ,, PAD=110.8 1 d�, 0�• , 1 �° . . off. o� TYP6�°A p:FE#11:�1;.00 5 ,+ Qo� �, _ ,-� OT- 11 i p r I d ! 4jo.PAD=; 10.3 -I-� IT.10 • 1 1 1 AND' • 1G...'V-8WA\1 LOT 29 '•'o: :. 6:1..`SIDE. 'SL:OPE RAD=110,2 :.100 TYPE A. . ,00, ti �o '.FF=110.40 PAP=109.7 + 1 `TaYPE: B 1 °p.FF=110.4Q�`o . , LOT 28 1 -9_TYPE-A .70 o I `SLOT: 13 - ; 06.9 'f FF=109.80 YPE' B,� LOT 27 PAD=199:1-'- 105 �� ► I +� IT o PAD 07.5 6• - 104:10 FF=109.10 10 rx °rn o' ,.. - TYPE B ' ,� �, 6ti F=107.30 1 LOT 26 +� .2. o) �orq:: LOT 15 PAI108.4__, • PAD=106..E �o =106.7.0':'. • TYPE-B � TYPE B �o� T 1..6 :. 70 . ' PAD=106.0' 5 TYPE B'. :.�. 0r� -, `` 1 6 ate.. :, \` �.. . ,; • . \�P �°�,Z - Fc os.z LOT •25 `PAD=1'08.2 PK ro r108.5'b `�:. SUMP 0 PAD17.8 T E B o•c,•4. `1 Qzo LOT ❑•o•. p'I PAD.-107 �* --- -----TYPE B ' o 10 RAD=106.7 o WF F=1 f1B_Rf1- _ ..' , �•'�° ....:ice SKETCH ONLY SEC_9�5 TWP._�6—S, RNG. 21—E. PLOT PLAN NOT A BOUNDARY SURVEY BEARING BASIS: LOT 9, BLOCK 6 SILVERADO RANCH SUBDIVISION PHASES 6, 8 & 9A EAST BOUNDARY OF SUBJECT PLAT BEING N 02*35'32" E PASCO COUNTY, FLORIDA. THIS SURVEY IS SUBJECT TO ANY FACTS THAT N MAY BE DISCLOSED BY A FULL AND ACCURATE PRELIMINARY DRAWING: ON LOT AREA CALCULATIONS TITLE SEARCH. ALSO SUBJECT TO SETBACKS, THIS PLAN IS FOR PERMITTING PURPOSES LOT = 6325,00 Q. FT� EASEMENTS AND RESTRICTIONS OF RECORD. ONLY, NOT FOR CONSTRUCTION. VERIFY LIVING AREA =__j5f6___SQ. FT. b STEM WALL, AND ALL DIMENSIONS BEF013E ANY CONSTRUCTON. ENTRY = 45 —SQ. FT. UNDERGROUND FOOTER, GARAGE = 407—SQ. FT. UNDERGROUND UTLITIES ARE NOT LOCATED OR LEGEND: COVERED LANA] =__N/L_SQ. FT. SHOWN. PROPOSED DRAINAGE FLOW PATIO = 23.---SQ. FT. DO NOT SCALE THIS PRINT. DIMENSIONS AND CONC. DRIVE =_.�%L7 —SQ. FT. Gj (00.00) PROPOSED GRADE _j NOTES TAKE PREFERENCE. A/C & CONC PAD = 18 Q. FT. < E-00.00 EXISTING GRADE 0 PRIVATE SIDEWALK =--;Lg— Q. FT. DESCRIPTION NOT CONTAINING PLAT BOOK AND IMPERVIOUS =___c----7. + PAGE INDICATES THAT PLAT IS IN NOTES: =__Z5_K_SQ. FT. PRELIMINARY STAGE AND IS SUBJECT TO LOT GRADING TYPE = B SOD 3740 SO. FT. CHANGE AND/OR REVISION. PROPOSED PAD ELEVATION 111.6' FRONT SETBACK = 20' OFF LOT AREA CALCULATIONS CERTAIN DATA SHOWN HEREON BASED ON SIDE SETBACK 7.5' RIGHT OF WAY =__j0_3&OO SQ. FT. ENGINEERING PLANS PROVIDED BY CLIENT. REAR SETBACK 15' DRIVE APRON =_233SQ- FT. PUBLIC SIDEWALK =__Z_8EL_SQ. FT. 10' UTILITY EASEMENT SOD 514--SQ. FT. 10' DRAINAGE EASEMENT TOTALS AREA =__13(�0.00 SQ. FT. DRIVEWAY FT. SIDEWALK _-Al_7SQ. FT. SOD =__�L254 SQ. FT. LOT 8 BLOCK 6 00 -6 Lij '�d -6 S 87-24'28" c- _N �I— (p Lli 0' :b ry 0 W 65'-0" A/C u') L0 < LLJ Uj to < V)z 0�_ 0) 0<:�: ry:� Q_ — (n Lj<R 09 Ld _j 0 TRACT A m a_ t1i C\j DRAINAGE AREA z in :4 —31.'C7;- 22.50' 0 CL 10 1 117*24'28" W 110.00, 919 LOT 10 04 BLOCK 5 (o m 00 I to x 0 1 PC(P) PROPOSED:- z LOWEST FLOOR ELEVATIONS: LIVING AREA: 112.30' GARAGE AREA: DESCRIPTION: ELEVATIONS REFERENCED TO 7�) LOT 9, BLOCK 6, MAP OR PLAT ENTITLED "SILVERADO RANCH SUBDIVISION PHASES NORTH AMERICAN VERTICAL 6, 8 & 9A". AS RECORDED IN PLAT BOOK 075, PAGES 075 THROUGH 080, OF THE DATUM OF 1988. MEAN SEA PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. LEVEL= 00.00 FT. a no "X" APPARENT FLOOD HAZARD ZONE. COMMUNITY PANEL NO. 120230 0455 D EFFECTIVE DATE: 09/30/1992 LEGEND: (C)= CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA. (P)= PLAT DATA, rt= CENTERLINE, A/C= AIR CONDITIONER. 13/C= BACK OF CURB, C/S= CONCRETE SLAB, CH- CHORD, CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= COVERED, E/P= EDGE OF PAVEMENT, ESM'T= EASEMENT, F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND )RON PIPE, FIR= FOUND IRON ROD, FN&D= FOUND-NAIL & DISK, FPP= FOUND PINCHED PIPE, LFE= LOWEST FLOOR ELEVATION, MAS.= MASONRY, OR= OFFICIAL RECORD BOOK, PB= PLAT BOOK. PCP= PERM-ANIENT CON M01,POINT, PRM= PERMANENT REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 112" IRON ROD & CAP No. 4493, SN&D= SET NAL&'JASK. _!IiM�. ,-TEMPORARY BENCHMARIK, U/P= U11LITY POLE, W/F�- WOOD FENCE, (R) = RADIAL Drawn By. Square Feet: .6325 )MES HN R.BEACH&ASSOCIATES,INC. sms JO SURVEYORS AND MAPPERS Checked By. J t 911 WEST ST. PETERSBURG DRIVE JRB 6 ONE OLDSMAR, FLORIDA 34677 I Scale: WAY (813) 854-1276 FAX (813) 855-8370 1.1 =30' NOT VALID WITHOUT THE- SIGNATURE AND IDote of Survey. h-4e, 5 THE ORIGINAL RAISED SEAL OF A FLORIDA 01/141V BEACH #)ATE LICENSED SURVEYOR AND MAPPER JAM- AAA1 LORID EG. ND SURVEYOR No. 29*84 /LB#4493 Revisions: L