Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
18-19516
CITY OF ZEPHYRHILLS j 5335-8TH STREET (813)780-0020 195 06 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL PERMIT INFORMATION • LOCATION INFORMATION Permit#:19516 Issued: 4/03/2018 Address: 6671 WAGON TRAIL ST Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 343,131.90 Total Fees: 11,741.19 Subdivision: SILVERADO Amount Paid: 11,741.19 Date Paid: 4/03/2018 Parcel Number: 05-26-21-0080-00600-0390 CONTRACTOR INFORMATION OWNER INFORMATION Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC Addr: 4600 W. CYPRESS ST STE 200 Address: 4600 W CYPRESS ST STE 200 TAMPA, FL. 33607 TAMPA FL 33607 Phone: (813)574-5743 Lic: Phone: Work Desc: CONSTRUCT SINGLE FAMILY 3,046 SQ FT APPLICATION FEES BUILDING FEE 1,324.40 ELECTRICAL FEE 274.50 PLUMBING FEE 183.00 MECHANICAL FEE 128.10 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE-sfr/100% 4,828.00 SCHOOL IMPACT FEE-sfr/1% 48.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32 Inspections RequirgU FOOTER 2ND ROUGH PLUMB MISC INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there.may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications and Must Accompany Application. All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. GVAA_� . &__ CONTRACTORS SIGNATURE PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER PASCO COUNTY FLORIDA "- Permit Nd. Date Permitted 3--< Builder Name/Owner-Name l .- Control#.' County Parcel No. (9 2(0- �"�tt7-O dlv0�-Urle 8uiapiv: L}Jrx {� AddresslLocation 7 ZA)q al L.Sr f Classiflcationrrype of Use Z.� _ e TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: Z�— Exempt Q+Yes ❑No How Determined impact Fee Amount $. 3i Viz' Zone No. TAZ: SCHOOL IMPACT FEE Account (056) Single-Family Detached House Amount $ (057) Mobile Nome (05$) Other Residential 123) Collection Fee Exempt Yes D..ft How Determined PARKS AND RECREATION FEE Land Account Land-Credit Land Total. Recreation Account Recreation Credit •Recreation'Total Zone TOTAL,AMOUNT $ 70-' c% Exempt Yes n No How Determined LIBRARY FEE Land Account Land Credit. Land Total Facility Account Facility Credit Facility Total Exempt. ❑Yes No How Determined Total Amount RESOURCE FEE ERU TOTAL AMOUNT Prepared By Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE BEEN PAID AND RECEIPTED FOR BY•-CENTRAL PERMITTING OFFICE-OF PASCO COUNTY Acimowledgemsrit below does not Imply acceptance,of conrurence,.but simply receipt of-a copy of this forth,placing l the bullding permit owner on notice of this.assessment and the ccndltions of payment for same. DATE RECEIVED BY RECEIPT NO. DATE BY kJet StreamP Ultra Blowing Wool Insulation NA� - Attic and Cavity Wall Card Rme,h mve, en& -,6, CV Batts and Blankets Equipm-ent Required When Installed in accordance,with the manufacturer's 11 is recommended that a pneumatic blowing machine and a corfuglated-hosevoith a minimum 1/4n internal corrugation,a minimum length oo remmen dations,Knauf Insulation batts and blankets will of 1150".Coils in hose should not be.n th_ I-ess.-than V in,diameter.Acceptable material fied rate.is 5.-35 k' hfl nu te.ketcommende-d feed provide the full R-valu-a. rate is 15-25 lb§1minute. R-Value* Minimum Thickness TKOrmall Performance' pidewall and Attic Application) The slated thermal:tesistance(11-Value)is provided by installing in accordance with the manufacturer's Instructions.Failure'to Install the To obtain an Installed Insulation should reguired-numller of baser 1,000 scitiare feet and exceeding.the maximurn squar 1 6 feet of C-overage.per bag as reciornmended by�he-label Insulation resistance (R-Value)of: net be less-thirk: Y411 result in lower installed R-values,Field blending of this product with other loose fill insulations is not recommended by the manufacturer. R-49 13.75'! Cavity Wall gag Net.Weight-N-ominal 32 lbs.,Minimum 31 1 1 bs. R-38HD 10.25" R-38 12.00" 1114alue* Bags per 1006 81`- MaxITu.W Net i Minimifrin R-30HD 9.25" To obtain an The number of bags Coverage per Bag Weight per SF 16sulation per 1,000 square feet Contents of this The weight per square R-30 10.00, Cavity resistance of net area should not bag should not feet.of Installed Insulation R-26 9Z" Framing Depth of: Density be less than; cover more than: should not be less than: R-22 6.50'! 2"9 4" 3.50" R-1 5 1.8 lbs./cu.ft, 16.4 bags 61.0 sti,ft: 025 ft. I R-21 HD 5.50" 2"x 6" 5.50" R-.23 1.8 lbs R 88.6 so.fi;.ku. . 25.8 bags Okti lbs. R-19 6.25"" 2"x 8' 1.26 R-31 1.8 lbs.Icu.ft. 34.0 bags 29.4 sq.ft, 1,0BB lbs. R-151101 3.501, R-13 3.501, 2"x 1 V E5" R-39 1.8 lbslcu.ft. 43.4 bags 23.1 Sq,rft. 1:388 lbs. R-11 1.50" R Sears rosislence to,heal flow.The lt�I ku the R-vdk,the greeter.the Insulting power,To gel the marked R-yalue,it isomnlia!I.hal this Insulation be.installed properly. R-8 2.50" .,mii In a 5,5"cavity.Ccnforms to Adffl U65'and Federal Gpe n Atti c App I icatio n Bag N et Wei g ht-Nom in a 132 1 b.s.,M i n infurn 311 bs S*fkafiitri HH-1.521F. Minim.urn Bags/ Ma-ximurn Minimum Initial Settled Framing Adjustment 9F Coverage Weight fiistall6cl Thickness** To compensate for framing members,the number of bags per The number of bags/ Contents of this: The weiht/SF Thickness Contents,of this 1.. 00 sq.ft.of area lo,be Insulated should be as shown Wow. R-Value* 1'. area 000 S of net bag should not OfAnstalled Installed Insulation bag should To obtain an insulation• sh6uld not be less cover Insulation should ould not should not'be loss. not cover more -Bap/MSF resisialicei(R-Value)of: than: more tkarft ba less than than:: th.an Joist 16"O.C. 24"OX. R-Value Dimensions Framing F r a in I ng' Rn60 29.7 313.6 SF 952 lbs. 19.750" 19.750" 2x4 29.2 2q._4 R-49 23.5 -42.5 SF .7E Us. 16,375" 16.375" R-6.0 24_____ 28.9 29.1 R-44 20.9 47.8 8F .670 lbs. 14;875' 14.875" 2x8 28.6 28.9 R-38 17.8 56.2 SF .569 Ibs. 13.000- inow 2x4 23.0 23.2 R-30 13.6 73.3 SF A7 lbs. 16.375" 10.375" R-49 2x6 22.7 22.9, R-26 11.8 85.0 8F _87 lbs, 9.125" 9.125" 2X8 '22.4 22:7 2x4 20.4 20D'6 R-22 9.8 1022SF 313 lbs. 7.750" 7.750" R-44 2x6 20.1 20.3 R 198.4 1119.3.S_F Ag lbs, 6.750" 2x8 19.8 20.1 R-13 5-.7 1 1 75;3 SF .183,lbsi 4;750" 41.50" 2A 17.3 17.4 R-11 4.7 210.8 Sic, .152 l6s; 4.000" 4,06F7 R-38 2x6 17.0 17,2 Bag Net WilqIII-NOrninal 32 lbs;14.n'mn 31 Ih 2x8 16.7 '17.6, Coerage.and Installation date rmra determined whs a Voev:lUe 0 blawig machae to third sea,A,b n'ga:e operynq.200 a-,I pessure and I-5V of hose. rs I Wo colfairts to ft pM dl1a=rd;ncoW.J C68 C 518, 2x4 13.2 13.3 �. bn HH-14030S,Type 1,Class B.R-Mes are dalenS,'re, 7 and ro5j5Wv,*to heal Sm.The hightr,the R-volx,4to gualor tSt,hts�ako poymr.To got the rtarked_R.va!_"e,11-B ft insealion be Inra4ed rnp-.:j,If you do It ytiurs,,Y,gn iftsvm- R-30 2x6 12.9 13 t 'and ID56-V kin izreWy.Inatrekkas do Sol crome-Mlh V3 packaga. .1 onson T611,d Pody2-par selflna SlAy,the oVal a 20-e Fierloal Im.4i be I F&=l of 1ess.This it,rmuftl of set:mg Is tnklrla!ty KsWf`r canlTrive 11,rainsta edoldWded 2x8 12,6 12.9 _��T 2x4 11.3 11 A V�u[AaWll Is a registered Weinhrk of Urtisul. R-26 2x6 11.0 -11,.2 Builder's Insulation Statement 2x8 10,8 11.0 Jet Stream Ultra has been Installed in c6riformbrice with the included recommendations to provide a th6nnal resistance of 2x4 9.'3 9.5 R-Value Thickness R-22 2X6 9.1 Y.3 Attic-Area R at Inches 2x8 _8.8 9,1 'Sloped Ceilings R.- at Inches 2x4 7.9 8.1. Walls R- at Inches' 1119 2x6 7.7 7.9 Floors(ow an unheated crawl space) R- it' Inches 2x8 7.4 7:7. 2x4 5.3, 5.4 Crawl Space Perimeter R_ at inches, R;.13 2x6 5.0 5,2 DatedristbIled I 2x8 4.8' 5.0 Blown insulation has been installed in conformance with the-above.recommendations to provide an R=value of: 2x4- 4.3. 4.4 R- & i 9 'square feet of areaUsing bags of this insulation to cover 1�r R-1 I 2x6 4.1 1 41 atarninimurrithickness-of %0, 'inches. 2x8 3.8 4.1. UL lnSuNon CDrararAg-(ignature)CI REENGUARD G.IA- A(11 X-f 1klan L'Adha UL GRUNGUARD GOdxr.d N Company. Date LAL I nW w4,1..d.bo f UL 1'"I;'rn.-W. GREENGLI.ARD Home Builder(signature) C.Isfl,.ao in prnam.- N;4 6 1..d to UL En.kmkj CAHNIWAM d rar 6 Lr,r6rr,161 Company, Date oir dai-a p,!A"m'. I The coverage Information on this MOSIdewall bard applies to the entire United States(including Minnesota). wwwAnaulfintuliition.us Knbuf Insulation,Inc: One Knauf Drive,Shelbyville,IN 46176 Tel:(80D)025-4434 ext:8300 FAX:(317)398-3675- oni r v_a --- - -- - -"- - -- - -- --- —t _ t , Ruildins;.unl(nst.uviceir,n 5:n iu•s(IKti7 'Jul I i D sc A. C.c-)U N l-1' FLORIDA_, BI,ower Door TL Report Form Property Address: unit U, � L6 71 t ( P ! 3 I Perm"n tl: resting Company Name:SKYETEC j TestoaW �O Tmor HASSEN KNEI.IFI "Tester rent p:MY3YG6 904-903-1076 i Er.�i:1Tlclieliff@sk etec.com 402.4.1.2 Testing.Building envelope airtightness shall be demonstrated by Section 402.4.1 2 31 The building or dwelling unit shall be tested and vc feed as having an air leakage rate of no;exceeding 5 air changes F peT hour. Testing shall be conducted with a blower door at a ptkwsure of 0.2 inches w.g.(50 Pascals).As required by the Building Official,gating shall be conducted by an approved third pany.A wriHcn report of the results of the test shall be signed by the party conducting the teat(including Agency tame)and provided to the Building Official prior to j Certificate of Occupancy issuance.Testing shall be performed at any time after creation ofall scheduled penetrations of the building thermal envelope t During testingr(check to verify condition nw) I Exterior windows and doors,fireplace and stove do_ors shall be closed,but not sealed,beyond the intended weather- stripping or other t/]Dampers:including exhaust,intake,makeup air,backdraft and flue dampers shall be dosed,but not sealed beyond V mtendedinfiltration 1 Interior doors,if installed at the time of the test,shall be open j to Exterior doors for continuous ventilation systems and heat recovery ventilators shall be dosed and sealed V/ eating and cooling systems,if installed at the time of the test,shall be turned oft` upply and return registers,if installed at the.time`of the test,shall be fully open ! Vb Building volwne(113) Qso Airflow at 50"Pascal(CFM) _ ? I ACHso Air changes per hour at 500 Pascal Qso x 60-Vb ACHso(3.0 ACH minimum) i Pass Fail ! Outside Air mechanically introduced to space(less than 3.0 ACH) } 7 hereby cent fi,that the above envelope leakage performance results demonstrate compliance with Florida Energy Code requirements in accordance wit/r.Section R402.4.11. I Signature of Tesler Da e ` 1 1 i CITY OF " NOTICE / / BUILDING ZEPHYRHILLS DEPARTMENT OF ADDITION OR CORRECTION D • NOT REMOVE ADDR SS DATE PERMIT* THIS JOB HAS NOT BEEN COMPLETED. he following additions or corrections shall be made before the job will be accepted. It is unlawful for any Carpenter,Contractor,Builder,or other persons,to AFTER CORRECTIONS ARE MADE CALL cover or cause to be covered,any part of the work with flooring,lath,earth 780_0020 FOR RE-INSPECTION or other material,until the proper inspector has had ample time to approve the installation. OFFICE HOURS 7:30AM-4:30 PM MON.-FRI. INSPECTOR Oti � City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: % On", :WDate Received: � Site: Permit Type: 1 D'`t �C' Y � - V Approved w/no comments:El Approved w/the below comments: Denied w/the below comments: 0 This comment sheet shall be kept with the permit and/or plans. Kal ' '' itze lans Examiner Date Contractor and/or Homeowner (Required when comments are present) 111111111111111I111I111111111111111111���I 2018053283 Rept:1944465 JRec: 10.@@ IT: 0.00 p5: @.00 pptY Clerk 04/@2/2018 K• A,'-- pgULA S.0'NEIL,018 09:35am Ph.D.PASCO CLERK-& COMPTROLLER 04/02/2 1 of 1 OR BK 9°701 221 Permit No. Parcel ID No 05-26-21-0080-00600-0390 NOTICE OF COMMENCEMENT State of Florida County of Pasco THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 713,Florida Statutes, the following information is provided in this Notice of Commencement: 1. Description of Property: Legal SILVERADO RANCH SUBDIVISION PHASES 6,6&9A PB 75 PG 75 BLOCK 06 LOT 39 Street Address: 6671 Wagon Trail Street Zephryhills FL 33541 2. General Description of Improvement Single Family Residence/Pool/Screen Enclosure/Fence 3. Owner Information: Lennar Homes, LLC. Name 4600 W Cypress St, Ste 200 Tampa FL. 33607 Address City State Interest in Property: Name of Fee Simple Titleholder: N/A (If other than owner) Address City State 4. Contractor: Lennar Homes, LLC Name 4600 W Cypress St, Ste 200 Tampa FL, 33607 Address City State Contractor's Telephone No.: 813.574.5700 5. Surety: N/A Name Address City State Amount of Bond: $ Telephone No.: 6. Lender: N/A Name Address City State Lender's Telephone No.: 7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)(7),Florida Statutes: Lennar Homes, LLC Name 4600 W Cypress St, Ste 200 Tampa FL, 33607 Address City State Telephone Number of Designated Person: 813.574.5700 8. In addition to himself,the owner designates N/A of to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statutes. Telephone Number of Person or Entity Designated by Owner: 9. Expiration date of Notice of Commencement is one year from the date of recording unless a different date is specified: WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES; AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. STATE OF FLORIDA COUNTY OF PINELLAS Signature of Owner or Owners Authorized Officer/Director/Partner/Manager Vice President Signatory's Title/Office The foregoing instrument was acknowledged before me this 28 day of March by Steve Robert Smith as Vice President (type orit o icer,trustee,attorney in fact)for Lennar Homes LLC (name on b f of who instrument was executed). Personally Known N OR Produced Identification❑ ary Si re Type of Identification Produced Name(Print) E '8sa Holleran Verification pursuant'to Section:92.525,Florida Statutes. Under penalties of perjury, I declare that I have read the foregoing and that the facts stated in it are true to the best of my knowledge and belief. ELISSAM.HOLLERAN Signature of Natural Person Signing Above ' Oammi talon#FF W637 '90 Ex'ires June 8;2020'" wpdata/bcs/bcsform:> DondelThN7rorFolnln+unncetp0-3is7Ofp STATE OFLARMA, THIS IS TO CERTIFY THAT THE FOREGOING IS A ". TRUE AND CORRECT COPY OF THE pOCUMENT ON FILE OR OF PUBLIC RECORD IN THIS®F�ICE - ro�c�v r ©FFIOIALS'EALTHIS _ WITNESS MY HAND AN DAY OFCL OL { edsi RAULp S p'NEIL,CL Ct} DEPUTY CLERK By PASCO COUNTY, FLORIDA - - Permit No. 1 L 'Date Permitted ±3,Kg3 Builder Name/Owner Name i ttl f �48 u Control# y County Parcel No. (j$-4`V-6060-00600 SubDiv: ' r ` Address/Location 7 r Classification/Type of Use TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: S Exempt ❑Yes ❑ No How Determined Impact Fee Amount $. r �Z' Zone No. TAZ: SCHOOL IMPACT FEE Account (056) Single-Family Detached House Amount $ T 76 (057) Mobile Home (058) Other Residential 123) Collection Fee j Exempt [�Yes ❑No How Determined PARKS AND RECREATION FEE Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation Total Zone TOTAL AMOUNT $ 76 i Exempt ❑Yes ❑ No How Determined 1 LIBRARY FEE Land Account Land Credit Land Total Facility Account Facility Credit Facility Total �. Exempt ❑Yes ❑ No How Determined Total Amount RESOURCE FEE ERU TOTAL AMOUNT Prepared By Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE ! BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY Acknowledgement below does not Imply acceptance of concurrence,but simply receipt of a copy of this form,placing the building permit owner on notice of this assessment and the conditions of payment for same. DATE RECEIVED BY RECEIPT NO. DATE BY Lennar Homes-6671 Wagon Trail St-3,046 sq ft Column SQ. FEET PRICE MAIN OR LIVING: 3,046 $ 112.65 OTHER AREA UNDER ROOF: $ 88.00 OTHER: - $ - VALUATION $ 343,131.90 FEE SHEET $ 1,220.00 ADDRESS $ 40.00 DRIVEWAY $ 40.00 BUILDING: $ 1,324.40 ELECTRICAL: $ 274.50 PLUMBING: $ 183.00 MECHANICAL: $ 128.10 SUB-TOTAL $ 1,910.00 TOTAL $ 1,910.00 SEWER: n/a WATER: n/a IRRIGATION: $ - TOTAL: $ - WATER METER: n/a IRRIGATION METER F - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 2,463.35 PARK IMPACT FEES $ 769.56 SIF'S: $ 4,828.00 100.0% $ 4,828.00 1.0% $ 48.28 TOTAL: $ 4,876.28 T I F'S : $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 11,741.19 05-26-21-0070-00400-0180 1 Pasco County Property Appraiser Page 1 of 1 Data Current as Of: Weekly Archive - Saturday, March 24, 2018 Parcel ID 05-26-21-0070-00400-0180 (Card: 001 of 001) Classification 00 - Vacant Residential Mailing Address Property Value LENNAR HOMES LLC Ag Land $0 4600 W CYPRESS ST STE 200 Land $27,016 TAMPA FL 33607-4099 Building $0 Physical Address Extra Features $0 6671 PADEN WHEEL STREET ZEPHYRHILLS, FL 33541 ]ust Value $27,016 Legal Description (First 4 Lines) Assessed (Non-School Amendment 1) $27,016 SILVERADO RANCH SUBDIVISION PHASES 2, 3 &4 PB 73 PG 059 BLOCK 4 Taxable Value $27,016 LOT 18 ]urisdiction City of Zephyrhills Land Detail (Card: 001 of 001) Line� se Descripti nZoning i Units ^ Type i O�rice ,Condition Value _— 1 _ 0100 _SFR— MPUD 6,000.00 _SF _ 1 $4.40 �_ 1.00 $26,400 2 0100 SFR MPUD 1,539.00 SF $040 1.00 $616 Additional Land Information Acres 4 0.17 iTax Areal 30SI ( Code -- i Residential Code i SLVRCPI Building Information - Use 00 - Unimproved (Card: 001 of 001) Unimproved Parcel 00 - Unimproved Extra Features (Card: 001 of 001) _ Line T Description —u Year (Units Value No Extra Features Sales History - See All 6 sales Previous Owner: DUNE FL LAND I SUB LLC Month/Year Book/Page Type T_~ _ IDOR Code Condition mount _03/2018 - 9694 / 3124 , Warranty Deed 05 L Vacant F Multi-Parcel Sale- 09/2011 8606 / 3376 _Warranty Deed—j 05 i Vacant Multi-Parcel Sale 05/2010 8373 / 1912�—I Certificate of Title 12 Vacant $0 http://search.pascopa.com/parcel.aspx?parcel=2126050070004000180 4/2/2018 Lennar Homes-6671 Wagon Trail St- 3,046 sq ft Column tj SQ. FEET PRICE MAIN OR LIVING: 3,046 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 343,131.90 FEE SHEET $ 1,220.00 ADDRESS $ 40.00 DRIVEWAY $ 40.00 BUILDING: $ 1,324.40 ELECTRICAL: $ 274.50 PLUMBING: $ 183.00 MECHANICAL: $ 128.10 SUB-TOTAL $ 1,910.00 TOTAL $ 1,910.00 SEWER: WATER: -IRRIGATION: $ - TOTAL: $ - na WATER METER: IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 2,463.35 PARK IMPACT FEES $ 769.56 SIF'S: $ 4,828.00 100.0% $ 4,828.00 1.0% $ 48.28 TOTAL: $ 4,876.28 T I F'S : $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 119741.19 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 2575A1 sf ADS 2017 Builder Name: Lennar Homes Street: 6671 Wagon Trail Street Permit Office: Q of��ephyrhills City,State,Zip: Zephyrhills,FL, Permit Number: Owner: Lennar Homes Jurisdiction: 611600 Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(2613.1 sqft.) Insulation Area a.Frame-Wood,Exterior R=11.0 1264.00 ft2 2. Single family or multiple family Single-family b.Concrete Block-Int Insul,Exterior R=4.1 996.67 ft2 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 352.44 ft2 4. Number of Bedrooms 4 - d.N/A R= ft2 10.Ceiling Types (1491.0 sqft.) Insulation Area 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1491.00 ft2 6. Conditioned floor area above grade(ft2) 2584 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(175.6 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 218.6 a. U-Factor: Dbl,U=0.54 71.25 ft2 b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 298.2 SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.56 71.00 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.28 a.Central Unit 18.0 SEER:16.00 b.Central Unit 25.2 SEER:16.00 c. U-Factor: Dbl,U=0.56 33.33 ft2 SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 17.5 HSPF:8.50 SHGC: b.Electric Heat Pump 21.8 HSPF:8.50 Area Weighted Average Overhang Depth: 1.190 ft. Area Weighted Average SHGC: 0.300 14.Hot water systems a.Electric Cap:40 gallons 8. Floor Types (2584.0 sqft.) Insulation Area EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1093.00 ft2 b. Conservation features b.Floor Over Other Space R=0.0 1051.00 ft2 None c.other(see details) R= 440.00 ft2 15.Credits Pstat Glass/Floor Area: 0.068 Total Proposed Modified Loads: 74.77 PASS Total Baseline Loads: 74.82 I hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance ';+ havet!al�rcG� with the Florida Energy Code. PREPARED BY: Before construction is completed this building will be inspected for DATE: 9 P compliance with Section 553.908 * :� herebycertify that this building,as designed, is in compliance Florida Statutes. fY 9, 9 P with the Florida Energy Code. OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - '- - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3. 1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage n greater than 7.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage On requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.070 On for whole house. 2/1/2018 8:15 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5 i FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 2575A1 sf ADS 2017 Builder Name: Lennar Homes Street: 6671 Wagon Trail Street Permit office: City of Zephyrhills City,State,Zip: Zephyrhills,FL, Permit Number: Owner: Lennar Homes ,jurisdiction: 611600 Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(2613.1 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1264.00 ftz b.Concrete Block-Int Insul,Exterior R=4.1 996.67 ft 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 352.44 ftz 4. Number of Bedrooms 4 d.N/A R= ftz 10.Ceiling Types (1491.0 sqft.) Insulation Area 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1491.00 ftz 6. Conditioned floor area above grade(ftz) 2584 b.N/A R= ft2 Conditioned floor area below grade(ftz) 0 c.N/A R= ftz 11.Ducts R ftz 7. Windows(175.6 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 218.6 a. U-Factor: Dbl,U=0.54 71.25 ftz b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 298.2 SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.56 71.00 ftz 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.28 a.Central Unit 18.0 SEER:16.00 b.Central Unit 25.2 SEER:16.00 c. U-Factor: Dbl,U=0.56 33.33 ftz SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ftz a.Electric Heat Pump 17.5 HSPF:8.50 SHGC: b.Electric Heat Pump 21.8 HSPF:8.50 Area Weighted Average Overhang Depth: 1.190 ft. Area Weighted Average SHGC: 0.300 14.Hot water systems 8. Floor Types (2584.0 sqft.) Insulation Area a.Electric Cap:40 gallons EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1093.00 ftz b. Conservation features b.Floor Over Other Space R=0.0 1051.00 ftz None c.other(see details) R= 440.00 ftz 15.Credits Pstat Glass/Floor Area: 0.068 Total Proposed Modified Loads: 74.77 PASS Total Baseline Loads: 74.82 I hereby certify that the plans and specifications covered by Review of the plans and S7:= this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: Dave Aulich Before construction is completed DATE: this buildingwill be inspected for P LL ... compliance with Section 553.908 I herebycertify that this building,as designed, is in compliance Florida Statutes. .� fY 9� 9 P with the Florida Energy Code. CIO OWNER/AGENT: BUILDING OFFICIAL. DATE: DATE: � - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.070 Qn for whole house. 2/1/2018 8:15 AM EnergyGauge@ USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 2575A1 sf ADS 2017 Builder Name: Lennar Homes Street: 6671 Wagon Trail Street Permit-.office: City of Zephyrhills City,State,Zip: Zephyrhills,FL, Permit Number: Owner: Lennar Homes Jurisdiction: 611600 Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(2613.1 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1264.00 ft' b.Concrete Block-Int Insul,Exterior R=4.1 996.67 ft' 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 352.44 ft' 4. Number of Bedrooms 4 d.N/A R= ft' 5. Is this a worst case? Yes 10.Ceiling Types (1491.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1491.00 ft: 6. Conditioned floor area above grade(W) 2584 b.N/A R= ft' Conditioned floor area below grade(ft') 0 c.N/A R= ft' 11.Ducts R ft2 7. Windows(175.6 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 218.6 a. U-Factor: Dbl,U=0.54 71.25 ft' b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 298.2 SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.56 71.00 ft' 12.Cooling systems kB 18.0 Efficiency a.Central Unit 8.0 SEER:16.00 SHGC: SHGC=0.28 b.Central Unit 25.2 SEER:16.00 c. U-Factor: Dbl,U=0.56 33.33 ft' SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ftZ a.Electric Heat Pump 17.5 HSPF:8.50 SHGC: b.Electric Heat Pump 21.8 HSPF:8.50 Area Weighted Average Overhang Depth: 1.190 ft. Area Weighted Average SHGC: 0.300 14.Hot water systems a.Electric Cap:40 gallons 8. Floor Types (2584.0 sqft.) Insulation Area EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1093.00 ft' b. Conservation features b.Floor Over Other Space R=0.0 1051.00 ft' None c.other(see details) R= 440.00 ft' 15.Credits Pstat Glass/Floor Area: 0.068 Total Proposed Modified Loads: 74.77 PASS Total Baseline Loads: 74.82 I hereby certify that the plans and specifications covered by Review of the plans and 0 SArF this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance �`{'!ii;^' , `==z�;;.:�`, •�s' � with the Florida Energy Code. /ry� /� /I� PREPARED BY: Before construction is completed r� ►-. DATE: this building will be inspected for compliance with Section 553.908 * ^ herebycertify that this building,as designed, is in compliance Florida Statutes. fY 9� 9 P "�G, �j�a.• with the Florida Energy Code. QXj y OWNER/AGENT: BUILDING OFFI L. DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.070 Qn for whole house. 211/2018 8:15 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2017 PROJECT Title: 2575A1 sf ADS 2017 Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 2584 Lot# Owner Name: Lennar Homes Total Stories: 2 Block/Subdivision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: Lennar Homes Rotate Angle: 90 Street: Permit Office: Cross Ventilation: County: Pasco Jurisdiction: Whole House Fan: City,State,Zip: Zephyrhills, Family Type: Single-family FL, New/Existing: New(From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Tampa FL_TAMPA_INTERNATI 39 91 70 75 645.5 54 Medium BLOCKS Number Name Area Volume 1 Block1 1093 9399.8 2 Block2 1491 11928 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 1st Floor 1093 9399.8 Yes 0 1 Yes Yes Yes 2 2nd Floor 1491 11928 No 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio 1st Floor 102 ft 0 1093 ft2 —_ 0.3 0 0.7 2 Raised Floor 2nd Floor _—_ ---- 13 ft2 11 0 0 1 3 Floor over Garage 2nd Floor 427 ft2 11 0.2 0 0.8 4 Floor Over Other Space 2nd Floor 1051 ft2 0 0.� 0 0.8 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1613 ft2 0 ft2 Medium 0.85 No 0.9 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 1489 ft2 N N 2/1/2018 8:15 AM EnergyGaugeO USA-FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2017 CEILING # Ceiling Type Space R-Value -Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) 2nd Floor 30 Blown 1491 ft2 0.11 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 N=>E Exterior Concrete Block-Int Insul 1st Floor 4.0999 19 8 8 164.7 ft' 0 0.600000 0 2 E=>S Exterior Concrete Block-Int Insul 1st Floor 4.0999 38 8 8 329.3 ft2 0 0.600000 0 3 S=>W Exterior Concrete Block-Int Insul 1st Floor 4.0999 34 8 8 294.7 ft2 0 0.600000 0 4 W=>N Exterior Concrete Block-Int Insul 1st Floor 4.0999 18 8 8 156.0 ft2 0 0.600000 0 5 N=>E Garage Frame-Wood 1 st Floor 11 20 8 8 173.3 ft' 0 0.01 0 6 W=>N Garage Frame-Wood 1 st Floor 11 20 8 8 8 179.1 ft2 0 0.01 0 7 N=>E Exterior Frame-Wood 2nd Floor 11 40 8 320.0 ft2 0 0.600000 0 8 E=>S Exterior Frame-Wood 2nd Floor 11 39 8 312.0 ft2 0 0.6 0 9 S=>W Exterior Frame-Wood 2nd Floor 11 40 8 320.0 ft2 0 0.600000 0 10 W=>N Exterior Frame-Wood 2nd Floor 11 39 8 0 312.0 ft2 0 0.600000 0 11 S=>W Exterior Concrete Block-Int Insul 1st Floor 4.0999 6 8 8 52.0 ft2 0 0.600000 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N=>E Insulated 1st Floor None .2 3 6 8 20 ft2 2 N=>E Wood 1st Floor None .4 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered orientation => changed to Worst Case. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 3 S=>W 11 Metal Low-E Double Yes 0.56 0.32 N 33.3 ft2 2 ft 0 in 0 ft 6 in Drapes/blinds None 4 S=>W 3 Metal Low-E Double Yes 0.54 0.31 N 9.3 ft2 1 ft 0 in 10 ft 0 in Drapes/blinds None 5 N=>E 7 Metal Low-E Double Yes 0.56 0.28 N 16.0 ft2 1 ft 0 in 4 ft 0 in Drapes/blinds None 6 S=>W 9 Metal Low-E Double Yes 0.54 0.31 N 23.0 ft2 1 It 0 in 0 ft 6 in Drapes/blinds None 7 W=>N 10 Metal Law-E Double Yes 0.54 0.31 N 16.0 ft2 1 ft 0 in 0 ft 6 in Drapes/blinds None 8 N=>E 7 Metal Low-E Double Yes 0.56 0.28 N 32:0 ft2 1 ft 0 in 0 ft 6 in Drapes/blinds None 9 S=>W 3 Metal Low-E Double Yes 0.54 0.31 tJ 23.0 ft2 1 ft 0 in 10 ft 0 in Drapes/blinds None 10 N=>E 1 Metal Low-E Double Yes 0.56 0.28 N 23.0 ft2 1 ft 0 in 13 ft 0 in Drapes/blinds None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 427 ft2 427 ft2 41 ft 8.6 ft 1 2/1/2018 8:15 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2017 INFILTRATION # Scope Method SL.A CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000367 2488.2 136.6 256.9 .339 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 17.5 kBtu/hr 1 sys#1 2 Electric Heat Pump/ Split HSPF:8.5 21.8 kBtu/hr 2 sys#2 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 16 18 kBtu/hr 540 cfm 0.85 1 sys#1 2 Central Unit/ Split SEER: 16 25.2 kBtu/hr 756 cfm 0.85 2 sys#2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 40 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS —Supply— —Return— Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 218.6 ft 2nd Floor 54.65 ft Proposed Qn 2nd Floor —cfm 76.5 cfm 0.07 0.60 1 1 2 Attic 6 298.2 ft 2nd Floor 74.55 ft Proposed Qn 2nd Floor —cfm 104.4 cfm 0.07 0.60 2 2 TEMPERATURES Programable Thermostat:Y Ceiling Fans: CoolingJan Feb [ ]Mar Apr May Jun n Jul r ]Auge Oct Nov [ Dec Heatin Jan f X Feb [X]Mar E Apr f May Jun Jul ]Aug Sep E Oct Nov EX�Dec VentingJan [ Feb X Mar [x]Apr [ Ma Jun Jul 1 Au Se [Xl Oct X Nov Dec 2/1/2018 8:15 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2017 [Thermostat Schedule: HERS 2006 Reference Hours Schedule Thermostat 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 so 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 781 78 78 78 78 78 78 Heating(VVD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 2/1/2018 8:15 AM EnergyGauge@ USA-FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5 r } FORM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerformance Index, the more efficient the home. Zephyrhills, FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1264.00 ft2 b.Concrete Block-Int Insul,Exterior R=4.1 996.67 ft2 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 352.44 ft2 4. Number of Bedrooms 4 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types Insulation Area a.Under Attic(Vented) R=30.0 1491.00 ftz 6. Conditioned floor area(ft2) 2584 b.N/A R= ft2 7. Windows ' Description Area c.N/A R= ft2 a. U-Factor: Dbl, U=0.54 71.25 ft2 11.Ducts R ft2 a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 218.6 SHGC: SHGC=0.31 b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 298.2 b. U-Factor: Dbl,U=0.56 71.00 ft2 SHGC: SHGC=0.28 12.Cooling systems kBtu/hr Efficiency c. U-Factor: Dbl,U=0.56 33.33 ft2 a.Central Unit 18.0 SEER:16.00 SHGC: SHGC=0.32 b.Central Unit 25.2 SEER:16.00 d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 17.5 HSPF:8.50 Area Weighted Average Overhang Depth: 1.190 ft. b.Electric Heat Pump 21.8 HSPF:8.50 Area Weighted Average SHGC: 0.300 8. Floor Types Insulation Area 14.Hot water systems a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 1093.00 ft2 EF:0.95 b.Floor Over Other Space R=0.0 1051.00 ft2 c.other(see details) R= 440.00 ftz b. Conservation features None 15.Credits Pstat certify that this home has complied with the Florida Energy Efficiency Code for Building TIST Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed'Code c pliant features. Builder Signature: Date: 02/28/18 -. Address of New Home 6671 Wagon Trail Street City/FL Zip: Zephyrhills,FL 33541 4,:. � . *Note: This is not a uilding Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 2/1/2018 8:17 AM EnergyGauge®USA-FlaRes2017 -Section R405.4.1 Compliant Software Page 1 of 1 Building Analysis Job: 2575A1 sf ADS2017 g Y Date: 2/2812018 lower floor By: Dave BAYONET PLUMBING COOLING.HEATING Project Information For: Lennar Homes Design Conditions Location: Indoor: Heating Cooling Tampa International AP, FL, US Indoor temperature(°F) 70 75 Elevation: 10 ft Design TD (OF) 39 16 Latitude: 280N Relative humidity (°/n) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 34.7 54.7 Dry bulb(OF) 31 91 Infiltration: Daily range(OF) - 14 ( L ) Method Simplified Wet bulb(°F) - 77 Construction quality Semi-tight Wind speed(mph) 15.0 7.5 Fireplaces 0 • Component Btuh/ft2 Btuh % of load Walls 5.5 5179 31.9 ucts Glazing 30.2 2683 16.5 nfiltration Doors 21.2 419 2.6 Wall Ceilings 1.8 57 0.4 Floors 4.1 4478 27.6 Infiltration 1.9 2032 12.5 Ducts 1400 8.6 Piping 0 0 Floors Humidification 0 0 Glazing Ventilation 0 0 Doors other Adjustments 0 Total 16249 100.0 Component Btuh/ft2 Btuh % of load Walls' 2.8 2632 23.2 Internal Gains Glazing 56.3 5004 44.1 wall Doors 16.6 328 2.9 Ceilings 2.0 64 0.6 Ducts Floors 0 0 0 Infiltration 0.4 453 4.0 Ducts 1655 14.6 Infiltration Ventilation 0 0 Other Internal gains 1200 10.6 Doors Blower -0 0 Adjustments 0 Glazing Total 11336 100.0 Latent Cooling Load= 1233 Btuh Overall U-value= 0.150 Btuh/ft2-°F Data entries checked. + wrightsoft' 2018-Feb-28 11:35:32 ACCARight-Suite®Universal 2017 17.0.23 RSU05714 Page 1 ...BA27UHE AH's\2575Asf ADS template 1.5-2ton.rup Cale=MJ8 Front Door faces:SE r Building Analysis Job: 2575Alsf ADS2017 g y Date: 2/2812018 upper floor By: Dave BAYONET PLUMBING COOLING HEATING Project I • • For: Lennar Homes ,Design • • • Location: Indoor: Heating Cooling Tampa International AP, FL, US Indoor temperature(°F) 70 75 Elevation: 10 ft Design TD (°F) 39 16 Latitude: 280N Relative humidity(%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 34.7 54.7 Dry bulb(°F) 31 91 Infiltration: Daily range(°F) - 14 ( L ) Method Simplified Wet bulb(°F) - 77 Construction quality Semi-tight Wind speed (mph) 15.0 7.5 Fireplaces 0 Component Btuh/ftz Btuh % of load Walls 3.8 4219 32.8 u°t5 Glazing 30.2 2608 20.3 Doors 0 0 0 \Nall Ceilings 1.3 1870 14.6 nfiltration Floors 0 0 0 Infiltration 1.9 2307 17.9 Ducts 1846 14.4 Piping 0 0 Humidification 0 0 Ceilings Ventilation 0 0 Glazing Adjustments 0 Total 12850 100.0 FRO• • Component Btuh/ftz Btuh % of load Walls 2.7 3046 15.6 Walls Glazing 52.7 4554 23.3 Doors 0 0 0 Internal Gains Ceilings 1.7 2586 13.2 Floors 0 0 0 Infiltration 0.4 514 2.6 Ducts 2137 10.9 Glazing Ventilation 0 0 Internal gains 6725 34.4 Blower 0 0 Adjustments 0 Total 19562 100.0 Ceilings Infiltration Latent Cooling Load=2945 Btuh Overall U-value= 0.083 Btuh/ftz-°F Data entries checked. � + wrightsoft9 2018-Feb-28 11:35:32 ACCARight-Suite®Universal 2017 17.0.23 RSU05714 Page 2 ...BA27UHE AH's12575Asf ADS template 1.5-2ton.rup Calc=MJ8 Front Door faces:SE t Project Summary Job: 2575A1 sf ADS 2017 ry Date: 2/2812018 lower floor By: Dave BAYONET PLUMBING COOLING HEATING Project I • • For: Lennar Homes Notes: Design In • • Weather: Tampa International AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 31 OF Outside db 91 OF Inside db 70 OF Inside db - 75 OF Design TD 39 OF Design TD 16 OF Daily range L Relative humidity 50 % Moisture difference 55 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 14848 Btuh Structure 9681 Btuh Ducts 1400 Btuh Ducts 1655 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh none (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 16249 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 11336 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 939 Btuh Ducts 294 Btuh Central vent(0 cfm) 0 Btuh Heating Coolingg (none) Area(ftz) 1093 1093 Equipment latent load 1233 Btuh Volume(ft3) 9638 9638 Air changes/hour 0.29 0.16 Equipment Total Load (Sen+Lat) 12569 Btuh Equiv.AVF (cfm) 47 25 Req. total capacity at 0.85 SHR 1.1 ton Heating Equipment Summary Cooling Equipment Summary Make Lennox . Make Lennox Trade 14HPX SERIES Trade 14HPX SERIES Model 14HPX-018-230-21 Cond 14HPX-018-230-21 AHRI ref 10258596 Coil CBA27UHE-018-230*++TDR AHRI ref 10258596 Efficiency 8.5 HSPF Efficiency 13.0 EER, 16 SEER Heating input Sensible cooling 16915 Btuh Heating output 17100 Btuh @ 470F Latent cooling 2985 Btuh Temperature rise 26 OF Total cooling 19900 Btuh Actual air flow 600 cfm Actual air flow 600 cfm Air flow factor 0.037 cfm/Btuh Air flow factor 0.053 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.90 Capacity balance point= 31 OF Backup: Input=4 kW, Output= 15295 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. _Fkl htsoftm 2018-Feb-2811:35:32 .+_ Wrg Right-Suite®Universal 2017 17.0.23 RSU05714 Page,1 �� ...BA27UHE AH's\2575Asf ADS template 1.5-2ton.rup Calc=MJ8 Front Door faces:SE Project Summary Job: 2575A1 sf ADS 2017 ry Date: 2128/2018 upper floor By: Dave BAYONET PLUMBING COOLING HEATING Project Information For: Lennar Homes Notes: Design Inf• • Weather: Tampa International AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 31 OF Outside db 91 OF Inside db 70 OF Inside db 75 OF Design TD 39 OF Design TD 16 OF Daily range L Relative humidity 50 % Moisture difference 55 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 11004 Btuh Structure 17425 Btuh Ducts 1846 Btuh Ducts 2137 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh none (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 12850 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 19562 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 2566 Btuh Ducts 379 Btuh Central vent(0 cfm) 0 Btuh Heating cooling (none) Area(f:2) 1499 149g Equipment latent load 2945 Btuh Volume(ft') 11928 11928 Air changes/hour 0.27 0.14 Equipment Total Load (Sen+Lat) 22507 Btuh Equiv.AVF (cfm) 54 29 Req. total capacity at 0.85 SHR 1.9 ton Heating Equipment Summary Cooling Equipment Summary Make Lennox Make Lennox Trade 14HPX SERIES Trade 14HPX SERIES Model 14HPX-024-230-21 Cond 14HPX-024-230-21 AHRI ref 10258598 Coil CBA27UHE-024-230*++TDR AHRI ref 10258598 Efficiency 8.5 HSPF Efficiency 13.5 EER, 16 SEER Heating input Sensible cooling 21420 Btuh Heating output 21800 Btuh @ 47°F Latent cooling 3780 Btuh Temperature rise 25 OF Total cooling 25200 Btuh Actual air flow 800 cfm Actual air flow 800 cfm Air flow factor 0.062 cfm/Btuh Air flow factor 0.041 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.87 Capacity balance point= 17 OF Backup: Input= 3 kW, Output= 11787 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. ^` Wrl htso'fit- 2018-Feb-2811:35:32 9 Right-Suite®Universal 2017 17.0.23 RSU05714 Page 2 '�� ...BA27UHE AH's\2575Asf ADS template 1.5-2ton.rup Calc=MJ8 Front Door faces:SE Manual S Compliance Report Jab: 2575A1 sf ADS 2017 p p Date: 212812018 lower floor By: Dave BAYONET PLUMBING COOLING HEATING Project Information For: Lennar Homes Cooling Equipment Design Conditions Outdoor design DB: 91.3°F Sensible gain: 11336 Btuh Entering coil DB: 75.8°F Outdoor design WB: 77.3°F Latent gain: 1233 Btuh Entering coil WB: 62.9°F Indoor design DB: 75.0°F Total gain: 12569 Btuh Indoor RH: 50% Estimated airflow: 600 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: SplitASHP Manufacturer: Lennox Model: 14HPX-018-230-21+CBA27UHE-018-230*++TDR Actual airflow: 600 cfm Sensible capacity: 15300 Btuh 135% of load Latent capacity: 2700 Btuh 219% of load Total capacity: 18000 Btuh 143% of load SHR: 85% Heating Equipment Design Conditions Outdoor design DB: 30.8°F Heat loss: 16249 Btuh Entering coil DB: 69.6°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Lennox Model: 14HPX-018-230-21+CBA27UHE-018-230"++TDR Actual airflow: 600 cfm Output capacity: 17500 Btuh 108% of load Capacity balance: 31 OF Supplemental heat required: 0 Btuh Economic balance: -99 OF Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 600 cfm Output capacity: 4.5 kW 94% of load Temp. rise: 50 OF Meets are all requirements of ACCA Manual S. wri htsoft® 2018 Feb 28 11:age 1 9 Right-Suited Universal 2017 17.0.23 RSU05714 Page ' '� ...BA27UHE AH's\2575A sf ADS template 1.5-2ton.rup Calc=MJ8 Front Door faces:SE y Manual S Compliance Report Job: 2575Alsf ADS2017 P Date: 2/2812018 upper floor By: Dave BAYONET PLUMBING COOLING HEATING Project Information For: Lennar Homes Cooling Equipment Design Conditions Outdoor design DB: 91.3°F Sensible gain: 19562 Btuh Entering coil DB: 75.6°F Outdoor design WB: 77.3°F Latent gain: 2945 Btuh Entering coil WB: 62.8°F Indoor design DB: 75.0°F Total gain: 22507 Btuh Indoor RH: 50% Estimated airflow: 800 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: SpIitASHP Manufacturer: Lennox Model: 14HPX-024-230-21+CBA27UHE-024-230*++TDR Actual airflow: 800 cfm Sensible capacity: 21420 Btuh 109% of load Latent capacity: 3780 Btuh 128% of load Total capacity: 25200 Btuh 112% of load SHR: 85% Heating Equipment Design Conditions Outdoor design DB: 30.8°F Heat loss: 12850 Btuh Entering coil DB: 69.6°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: SpIitASHP Manufacturer: Lennox Model: 14HPX-024-230-21+CBA27UHE-024-230*++TDR Actual airflow: 800 cfm Output capacity: 21800 Btuh 170% of load Capacity balance: 17 °F Supplemental heat required: 0 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 800 cfm Output capacity: 3.5 kW 92% of load Temp. rise: 50 °F Meets are all requirements of ACCA Manual S. wri htsoft° 2018 Fel}28 11: ge 2 9 Right-Suite®Universal 2017 17.0.23 RSU05714 Page 2 '� ...BA27UHE AH's\2575Asf ADS template 1.5-2ton.rup Calc=MJ8 Front Door faces:SE 813-780:0020 City of Zephyrhilis Permit Application Fax-813-780-0021 Building Department Date Received Phone Contact for Permitting =813 363 __ 2891 —rrrrrrrr m— Owner's Name Lennar Homes,LLC Owner Phone Number r8l .574.5700 Owner's Address 1 4600 W.Cypress St.Ste.200,Tampa,FL 33607 Owner Phone Number Fee Simple Titleholder Name I N/A Owner Phone Number Fee Simple Titleholder Address I N/A JOB ADDRESS 6671 Wagon Trail Street LOT# 0390 SUBDIVISION Silverado Ranch Subdivision Ph 2,3,&4 PARCEL ID# 05-26-21-0080-00600-0390 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR B ADD/ALT 0 SIGN 0 Q DEMOLISH INSTALL REPAIR PROPOSED USE SFR Q COMM 0 OTHER TYPE OF CONSTRUCTION BLOCK 0 FRAME 0 STEEL 0 DESCRIPTION OF WORK Single Family Residence/Pool/Screen Enclosure/Fence BUILDING SIZE U/R SF 3046= SQ FOOTAGE 2584 HEIGHT 2 Story 'T�ITR'1�Tf ITI"ITI"1"7'�ITP'1'TPf rITITrI"ITITITrI"1'7�IT1"f"T'1"1"T�1"TT�T'1TT'1"tTITTR�r BUILDING $rL , t�1 VALUATION OF TOTAL CONSTRUCTION (ELECTRICAL $Q'� ® PROGRESS ENERGY Q W.R.E.C. AMP SERVICE PLUMBING $ MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION OGAS ROOFING 0 SPECIALTY 0 OTHER q5th FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA E1YES CIO / BUILDER COMPANY Lennar Homes,LLC SIGNATURE REGISTERED Y/ N I FEE CURREN Y/N Address 4600 W.Cypress St.Ste.200, ampa,FL 33607 License# CGC1518166 ELECTRICIAN COMPANY Edmonson Electric, Inc. SIGNATURE REGISTERED Y/ N FEE CURREN Address 1034 Skipper Road,Tampa FL 33613 License* EC13005408 PLUMBER COMPANY Bayonet Plumbing, Heating &AC, Inc SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address P.O. Box 5308, Bayonet, FL 4674-5308 License# I CFC042998 MECHANICAL COMPANY Bayonet Plumbing, Heating &AC, Inc SIGNATURE REGISTERED Y/ N FEE CURREN I Y/N Address P.O. Box 5308, Bayonet, F 34674-5308 License# I CAC058062 OTHER COMPANY SIGNATURE A REGISTERED Y/ N FEE CURREN Address 4211 Shoal Line Blvd, Spring Hill, FL 34607 License# CCCO57991 .� I11111111111111111111111111111111111111111111111111111111111I � � � � � RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over$7600) ** Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW d` NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor.or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-84778009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is$2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner"prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water[Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone W" unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90) consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. FLORIDA JURAT(F.S.117.03) OWNER OR AGENT I CONTRACTOR Subscribed and sworn to(or affin ed)before me this Subscribed and sworn to(or affir before me this '&o-reo-1 o by pawl Sweene 28-Feb-18 _ by Paul Sweene Who is/are personally known to or Who is/are personally knc or identification. as identification. Notary Public Notary Public Co fission No. FF98537 Commission No. FF98537 Elissa M.Holleran Elissa M.Holleran Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped �mA r, �e14N.�I®UIII �It19�Jikf.MCllxE�li}1 '�' �.'��cl�C�rem��'�N�f(+Of!�877 q` �aiidllY P�: iid'�Yr�P. Pa!aivanAaGgGy8S7Gll.a r,�'P.��alstvuro9���gSa'1G'10' — - - 'uro'! _ LOT 46 -'I PAD=123.4 . ,,ti x '►' ,' 121,. `,(+12a.a3 ,, N TYPE 'A,( TF,-c�,� 20,90 FF--122.29' 51 45 ' PD=122.2- ' PADT /21 5 124t 15' TYPE A PERT T 8 . , ' YPE TY ` ' ANI7 DRAINAGE,!,EASME r + J. ' s `�, x 121.87 , .5.34 ' x 123.83 x 1+23.27 J x 124.6 ,TA x119.6a , , , ,• E ' / f`,fin 1 '• ,+ � / r /1� ' 6` ` , FF=11,8 20 , 'F=.•118.2� r q °' I:. \ r - Lq•T. 4! LOT 2 PAD=1' 7.5 ' PAPS=117.5 ,/'TYPE A ,, 7YP'E p LOT 40 PAD=118,'Z ,PE D LA ` SCAF TYPE/A, r CS r !; CLUJI , ZA `1`. � i .�r., t'f0 .�'•'���� '��� 1�1P fit A y�, r1}��*` r e J"' ��( ,, ., i ^.�Y %' u i ;3*,ti. I inn 4'•. ! .q�,� ,'Ir'(' 117 y•'"�!0 Q J J r 1 'I f f��",.°'"`•• ire t' 1 ,. J' , & c� , �, irk /� /' _ �._ _ _l tea• # FF=120 30 f if # LOT, 38 1 i f r ` FF�117.60 ; a' PAD�119.6 ,1s.s .s. ,'`LOT 3 TYPE A ,� / i "t)AD=116,0 o , �.`Y'r rLQ �'�' .� i �,,i0 TYPE ,8 !` y. 4b' FF=I 1 8.70,r ' Xi 5. 6 Jr ,LOT 37' 'PAD-1,18.0 i . �i , ' jF.LOTb m ' '�`o . T E A j� /' PAD=114 �o `��'� TYPE' 8 z� ,,PF=l 16.30 LOT 36 /'FF=1-15.0 PAD=115.6 'r r' TYPE A r ,J o� , LOT P i ' AD=1,'#5,1 TYPE 8 ,. t o '.03 113 FF=115.30 , �• , � , LOT 35 ir' 'r 0=114.80( o 1� PAD==114.6 • ,, ,' sir i ;` LOT 41 TYPE A r� / / i / PAD=11'4.T.Ib*l r ' 1114A9 LQ'Tro°c i`!/ P -- j! ��0 ,r' LOT 7/' YPEk� o "'j PAD 11'38 2 "U_ , ! gyp., ..�.—.-. •cp ! r • $ to _ ,r i ' i � � ',�'� i .�. ' ri 1►5�i FF=1`13.60 ��,/ cv LOT 33 E i F=113610 g i ?AD=112 1 ; ,� LOT TYPE A ;' PAD=112.4 i % '� t' ' TYPE 8 S / -rl,. R` I . p { f i 1 ofn f ` i i SKETCH ONLY SEC. 05 TWP. 26 S, RNG. 21 E. PLOT PLAN NOT A BOUNDARY SURVEY LOT 39, BLOCK 6 BEARING BASIS: SILVERADO RANCH SUBDIVISION PHASES 6, 8 & 9A EAST BOUNDARY OF SUBJECT PLAT BEING N 02^35'32" E PASCO COUNTY, FLORIDA. T THIS SURVEY IS SUBJECT TO ANY FACTS THAT 1 MAY BE DISCLOSED BY A FULL AND ACCURATE PRELIMINARY DRAWING: TITLE SEARCH. ALSO SUBJECT TO SETBACKS, THIS PLAN IS FOR PERMITTING PURPOSES EASEMENTS AND RESTRICTIONS OF RECORD. ONLY, NOT FOR CONSTRUCTION. VERIFY ALL DIMENSIONS BEFORE ANY CONSTRUCTION. r�i UNDERGROUND FOOTER, STEM WALL, AND II UNDERGROUND UTILITIES ARE NOT LOCATED OR, LEGEND: SHOWN. ---= PROPOSED DRAINAGE FLOW DO NOT SCALE THIS PRINT. DIMENSIONS AND (00.00) = PROPOSED GRADE < NOTES TAKE PREFERENCE. E-00.00 = EXISTING GRADE I 0 DESCRIPTION NOT CONTAINING PLAT BOOK AND PAGE INDICATES THAT PLAT IS IN PRELIMINARY STAGE AND IS SUBJECT TO CHANGE AND/OR REVISION. o CERTAIN DATA SHOWN HEREON BASED ON ° ENGINEERING PLANS PROVIDED BY CLIENT. N o i N • = 10' UTILITY EASEMENT i ** = 15' DRAINAGE EASEMENT ON LOT AREA CALCULATIONS LOT = 12681.79 SQ. FT. LIVING AREA = 1093 Q. FT. ENTRY = 35 Q. FT. GARAGE = 427 Q. FT. S�jo COVERED LANAI = N/A Q. FT. I PATIO = 23 SQ. FT. CONC. DRIVE = 451 Q. FT. ��•, A/C & CONC PAD = 18 Q. FT. PRIVATE SIDEWALK = 31 SQ. FT. o IMPERVIOUS = 16 z I ,o LOT 40 = 2078 Q. FT. a^ C7 76 BLOCK 6 SOD = 10604 Q. FT. OFF LOT AREA CALCULATIONS c I RIGHT OF WAY = 687.32 SO. FT. Z a W DRIVE APRON = 235 Q. FT. 0 0 - * PUBLIC SIDEWALK = 208 Q. FT. cl I SOD = 244 Q. FT. to o m TOTALS cV I AREA = 13369.11 SQ. FT. _� 0 '�'a` DRIVEWAY = 86 6 SQ. FT. Bo SIDEWALK - 239 S0. FT. N z ............ ................................................ . SOD = 1 0848 SQ. FT. 78.62 1 o- - ^yam PLAT a =� a QO cv.T r� BOUNDARY Q �I Q�ov v �� OV ' ........................62.85' v •'• 2 /.• Jp 6q.7 O! 7 N :N Iq`f �• w. �Y. I ` V 8 045 42'w`126 --� Q `1%6 r f,, I M N 8T24'2p W u 30.00I -i�� Y LOT 38 v �� m NOTES: BLOCK 6 a LOT GRADING TYPE = A a PROPOSED PAD ELEVATION = 119.6' 1.'-.r• i FRONT SETBACK = 20' = SIDE SETBACK = 7.5' REAR SETBACK = 15' z DESCRIPTION: PROPOSED: o LOT 39, BLOCK 6, MAP OR PLAT ENTITLED "SILVERADO RANCH SUBDIVISION PHASES LOWEST FLOOR ELEVATIONS: 6, 8 & 9A", AS RECORDED IN PLAT BOOK 075, PAGES 075 THROUGH 080, OF THE LIVING AREA: 120.30' PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. GARAGE AREA: 1 ELEVATIONS REFERENCED TO 11 CURVE I RADIUS I ARC CHORD I BEARING I DELTA NORTH AMERICAN VERTICAL rn I C55 1 75.00' 1 8.70' 1 8.69' S 05's4'55" W 06-38'46 DATUM OF 1988. MEAN SEA C56 75.00' 43.39' 42.79' S 25'48'46" W 33'08'56" LEVEL= 00.00 FT. o 00 APPARENT FLOOD HAZARD ZONE: "X" COMMUNITY PANEL NO. 120230 0455 D EFFECTIVE DATE: 09/30/1992 O LEGEND: o (C)= CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, q= CENTERLINE, A/C= AIR CONDITIONER, B/C= BACK OF CURB, C/S= tQ. CONCRETE SLAB, CH= CHORD, CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= COVERED, E/P= EDGE OF PAVEMENT, ESM'T= EASEMENT, F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE, FIR= FOUND IRON ROD, FN&D= FOUND NAIL & DISK, FPP= FOUND PINCHED PIPE, LFE= LOWEST FLOOR ELEVATION, MAS.= MASONRY, OR= OFFICIAL RECORD BOOK, .PB= PLAT BOOK, PCP= PERMANENT CONTROL POINT, PRM= PERMANENT a REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SETA/2" IRON ROD & CAP No. 4493, SN&D= SET NAIL & DISK, TBM= TEMPORARY BENCHMARK, I U P= UTILITY POLE, W F= WOOD FENCE, R = RADIAL JOHN R.BEACH&ASSOCIATES,INC. Drawn By. SMS Square Feet: 12681.%9 LENNAR HOMES w SURVEYORS AND MAPPERS Y - 911 WEST ST. PETERSBURG DRIVE Checked B . i ONE OLDSMAR, FLORIDA 34677 JRB WAY (813) 854-1276 FAX (813) 855-8370 Scale: o 1"=30' •; NOT VALID WITHOUT THE SIGNATURE AND Date: PLOT PLAN 2 1 18 ACS a THE ORIGINAL RAISED SEAL OF A FLORIDA JOH R.BEACH _ - DATE LICENSED SURVEYOR AND MAPPER FLORID-,REG. LANO'•SUMYEYOP No. 2984 LB#4493 i Revisions: 5335 -8TH STREET (813)780-0020 CERTIFICATE OF OCCUPANCY i Address: 6671 WAGON TRAIL ST Owner: LENNAR HOMES LLC Subdiv: SIL ZE YRHILLS, FL. 4600 W CYPRESS ST STE 200 ADO Parcel: 05-26-21-0080-00600-0390 Work Type; 101 NEW CONST/SFR Construction Type: NOT APPLICABLE ❑ Sprinklers Use Classification: NOT APPLICABLE Permit Number: 19516 / Date: 7 30/2018 ISSUED B Warr*14UST BE CHANGED OVER WI7,�� eUl[DZ OFFS T BE APPLrE?PN qYS pF COAL oR TO ISSvANCE SSVANCE