Loading...
HomeMy WebLinkAbout18-19517 CITY OF ZEPHYRHILLS 5335-STH STREET (813)780-0020:, 19517 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL ,PERMIT INFORMATION LOCATION]N FORMATION Permit#:19517 Issued: 4/03/2018 Address: 3246 MOULDEN HOLLOW DR Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Loi(s'):..;' Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 267,656.40 Total Fees: 14,523.97 Subdivision: SILVERADO Amount Paid: 14,523.97 Date Paid: 4/03/2018 Parcel Number: .24-26-21-0060-0.0000-1000 CONTRACTOR INFORMATION OWNER INFORMATION Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC Addr: 4600 W. CYPRESS ST STE 200 Address: 4600 W CYPRESS ST STE 200 TAMPA, FL. 33607 TAMPA FL 33607 Phone: (813)574-5743 Lic: Phone: WorkDesc: CONSTRUCT SINGLE FAMILY 2,376 SQ FT . APPLICATION FEES BUILDING FEE 1,091.84 ELECTRICAL FEE 223.20 PLUMBING FEE148.80 MECHANICAL FEE 104.16 SEWER CONNECTION RESIDEN' 2,010.00 WATER METER RES 3/4" 473.78 WATER CONNECTION RESIDENI 641.00 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE-sfr/100% 4,828.00 SCHOOL IMPACT FEE-sfr/1% 48.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32 649 Inspections Required FOOTER-_ 2ND ROUGH PLUMB Misc INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL Misc misc. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER misc DRIVEWAY PRE-SLAB SHEATHING misc. misc. CONSTRUCTION POLE_ FRAME misc. misc. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the.fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for, improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. 0 CO TORS SIGNATURE PERMIT OFFIj9h PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIOW CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER 1 r I _ I•,t; �1� �•..11a� M.RIr�i'f►}! ?� �1ip►i►� iM0 .y ff�y'►�t*fl sr sN Ci• W, c ;• v^_> -•... I �Its�'�Ilaid*x li�iawr ft� Nil `' � -,all. ! y,i { � ..' .._- -.•-.'-.` i -swim� i P. �r' u._ t-y,l_-r,.ftp E�•}1 Er7 �, rr fr h j i F' i s;C y-I,ww" Li - ? VIP' +I ti,rll _ IN 1 ------------------------- 6s a� pr y -- - Poll l +' R H td`A�;IP*)n tit to ¢ a. lry e•.�l Yr/i1 r1-1 1— ')',.l�f —!�#�•1iTY Y. I'I{ I �I.�i r\ i 711 I� -� ._ _se ,�-- .r-Asa+-•s+.,:>.,•.....`J „� .e.,sv:+dwei-w�y�R+.�,�i•••���• � ,_ _ _ a._ _„r _-•, ae• x.c..i.y.>r_r_ < .x. ._.�:-..�,a:ar:�,r>.o:.+e ---!:l'G ± i I. I}rf• ''i 1.�► � �.�1. ► �C�_---�._ -�IdLIP llr `t_'�! I .:t T�i ,It'�'Y i .A Mill ?I t CA oil I I-. TU tz :�l�i,z= -i_i hr: -,-- ��!,'._ - Pi.�,�t' � 51_s -- - �t•;� - � R: . - _ - - ---- --- ? p •sue ��, .►...fi P! n'l�Y�• *•w � ,r►`f!ii,z'Ia�''t=' � .M ar-r MS►...�1� I ,yg.�r!..i.p r*l till^3!�s+ P►�Y�.:::.. ,�. I i:f e�N9it!'•fE .�.w.:.w.,r. all I�-tea c'..s•+a®'� --- --- ` rr,:e Im ...VM.O PJW + Ir+� ,r ..Est4 1 -mr-P rfl'iw I. 049 0—Wu ,_�.�aa7rgi INi ±�4i lol .I t�i4Fla'I• '� MI'�t'�rl Pillion � ! a .�.. }� ri i - - (�i51Y ta11 M��j.IF'.1i�'`/' b114!..bt;?, ► '.i. w ar. .N>+1,ti or =-Q--__ -_-_ -- .l.>r.w .�.r..,.--rn.�•�:u:r .j,rs.6_R l ON I Ih N —aa4Y_ --�"� a,; ;. i1•,�7, A ra�!I }i }l 1,4 Cst_1 I• I } �'►t`. I r'GI!C K - * �� .�G:? ` (l til yiLa'.11 ` yr',9i� r'�I►'s,. i r�+r1ti ! �i h • iL _�,: ;s■ i ::M v.�..:1 of P•I wort± w•.00 e—' EX ....>r..0 .-..,'I'll h ..u� .1 POW-ti -0 IN, '5 P9 errt�w r Al:I �L H •�IN•�w„►, I a ww• n a t JS"`�I�+ir4 E+t1�ufe 9� tE t I'I" to fn.iri+R I�+i J ��,I y.:w.nwy• t�[[t�++�'f'R-rt�lw ItNf Mi{�M'�► � ,. S. Cl•fa s >�...'---_._-"-_�'__�—_._ —__ ..y._, r,7+r1 T.r.+vt•M,;frw�w.�e . ••• �evr�it I r�r M .+►/rt fy•.,n.S.��r!•'i s!ere-•,. ,.,,� ,...-:!'•-_._..l:�.�rr•N �� ,1 "�."��twn �rrn..Ra+r.ew t .> ✓el! e.,. _Is.- .� rl.F_F.?_ ::'1.....:t .,.y-r, >•.�vs i f• �'. t r f J av:i5i atP'� � ` �' rr� •off d� ,�.ri 1� '� '� l � �,�:- !'��',- �'�,�' ��4LfYhl - �+ lq �rir cr lirAr, l ul 16+rA lu a4l �' ,� to� E Stmoo ar ru�7r'iwfd'?p 1'?fj )'f *'"To1J11M i0j4A% j at j ;d41'rA1WF Aioqn alp AW 4A l I � - ' L'�'�'�,�� rye, �,r�.x�la���R'►� �N��'� IIIJ7 II w-mJb.rw11RJ•OQ I V-41&4;A fuia*Lp,lit,p,&i#rgurl "4�ar�s a�'u wr y IPus Fj aEtn 'orI I t p' .� �'prt► >l c+�yl, 1 t*'�'t r,w 2 rr?1• _' E i, - - lam^i r -- -- �±, _ua'.� it Li ` times a _ �_ r - i � i o � � ' ► ,.,s, I �i mil r � n '�1il ski[w 4mfwig 4 [1 Co nFoa€7du.u;u r,.wu,'gum ssi ImI—lik Ilia aq 1Inpi-zilm irul ��r '4�e•nh���i'�,�3�►�.� W10T ttq.II-Nnli3�,�;��.n;:il�ar��5�uy.,� ��.i;�}r�ir�ila;�+i N 4��G<<r�1 _t'►�Ei���y��:i�,�&r�N��d� "�� s� till�1'� „*� V xfL�Pi�i1 ��s��r�'� '~ci F t"- « fi y �tG �r k H -41�1�& p��rr *:k :y�;�I� ;�yy�n .rg7}+�c i3gy'L i0miA I a! s S-mj#is�i i71 vwjp i'S] A*:r-! .LSE («j73a9i Fur !i""asu i I I A` li'- -v _ _'pI � pd ■nnLL J y _ -- --___ — fl4ll'L�C�p�x',' i'h r-61 _EIp����`I .'b>ii'M l!•LH- __— — .1' rx ,Y , ♦T�Arll i"0� Aq .wSaF>`{f Lujo I a';, ,a� , :�,, �I�.•.�, �y� �'giliii __�r ,� �, �,�i�' i"'{11nia,ii - s , PASGO COUN- TY DEVELOPMENT SERVICES 6731 Citizens Drive Date:7/3/20 18 - COUNTY RoiuDA New Port Richey, FL 34654 I'LV 727-:847-2411 D. A F-EFUN/H Receipt#: 1772626 FEE DESCRIPTION ACCOUNT CODE UNITS INVOICE FEE AMOUNT PAID RECEIPT# DATE1 Impact Fee Resideritial Solid. 2450-3100-329010- 34.010 1359943 $34.00 $34.00 1772628 7/2/18, Waste•8ingle,Family T-OTALS'- $3.4.00 $34M Receipt# Paid By Check#. CC Auth# Cashier ID Workstation Receipt ceipt Date Ami Paid 1772626 Check 01006012 BCCCP I 1OW 07/02/2018 $34,010 Total Payments: $34.00, Pavor Address Phone LENNAR HOMES 5246 MOULDER HOLLOW ,Comments: t while yqu.Will be paying your bill with Pasco county Development Services,the full amount of the credit card or e-check fees;NOT shown above,is collected by First BlIlling payment-rGiqes. MyReports/reportsI/PASCOPRODIPASCO/ReceiptPOS 'Mrpt 702b 18 Page 1 of 1 Jacqueline.Boges From: City of Zephyrhills Support<support@zephyrhillsfl.zendesk.com> Sent: Tuesday, April 3, 2018 3:22 PM To: Jacqueline Boges Subject: [Request received]3246.Moulden Hollow Dr ##- Please type your reply above this line -## Hello Jacqueline Boges, We are working to resolve your request promptly and will keep you updated. One of our Support Analysts will keep you updated on the progress of your request. Best Regards, FATHOM Support Team TO ADD ADDITIONAL COMMENTS, reply to this email or click the link below: https://zephyrhilisfl.zendesk.com/hc/requests/205726 ..............................................................................................................................................................................................................................................................................................................................................................:........................ Jacqueline Boges y- Apr 3, 12:22 PM MST Full service for 3246 Moulden hollow dr water, sewer and water meter This email is a service from City of Zephyrhills Support . 1 Lennar Homes-3246 Moulden Hollow Dr.-2,376 sq ft Column ts SQ. FEET PRICE MAIN OR LIVING: 2,376 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 267,656.40 FEE SHEET $ 992.00 ADDRESS $ 40.00 DRIVEWAY $ 40.00 BUILDING: $ 1,091.84 ELECTRICAL: $ 223.20 PLUMBING: $ 148.80 MECHANICAL: $ 104.16 SUB-TOTAL $ 1,568.00 TOTAL $ 1,568.00 SEWER: $ 2,010.00 WATER: $ 641.00 IRRIGATION: $ - TOTAL: $ 2,651.00 WATER METER: $ 473.78 IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 5,246.13 PARK IMPACT FEES $ 769.56 SIF'S: $ 4,828.00 100.0% $ 4,828.00 1.0% $ 48.28 TOTAL: $ 4,876.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 14,523.97 Lennar Homes-3246 Moulden Hollow Dr-2,376 sq ft Column ts SO. FEET PRICE MAIN OR LIVING: 2,376 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 267,656.40 FEE SHEET $ 992.00 ADDRESS $ 40.00 DRIVEWAY $ 40.00 BUILDING: $ 1,091.84 ELECTRICAL: $ 223.20 PLUMBING: $ 148.80 MECHANICAL: $ 104.16 SUB-TOTAL $ 1,568.00 TOTAL $ 1,568.00 SEWER: $ 2,010.00 WATER: $ 641.00 IRRIGATION: $ - TOTAL: $ 2,651.00 WATER METER: $ 473.78 IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 5,246.13 PARK IMPACT FEES $ 769.56 SIPS: $ 4,828.00 100.0% $ 4,828.00 1.0% $ 48.28 TOTAL: $ 4,876.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 14,523.97 • �O II;OIIIUH City of Zephyrhills ~� BUILDING PLAN REVIEW COMMENTS " Contractor/Homeowner: f Date Received: Site: 32-4� &�f&W 0�iD2 Permit Type: 2 3 S Approved w/no comments:❑ Approved w/the below comments: Denied w/the below comments: ❑ 64� ( �c This comment sheet shall be kept with the permit and/or plans. i ,mil Kalvin witzer ans Examiner Date Contractor an or e e (Required when comments are present) • . . I lillll lllll lllll lllll lllll lllll lllll lllll lllll lllil llll llll 2018053281 • Rcpt:1944465 DS: 0.00 I1ReO0.00 00 04/02/2018 K. R. , Dpty Clerk — pRULR S.o'NEIL,Ph,D.Sco m CLERK of c1 pTROLLEh 04/02/201 OR BBy, I�q —FG 219 - i — — Permit No. Parcel ID No 24-26 21-0060-00000-1000 NOTICE OF COMMENCEMENT State of Florida county of Pasco THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement: 1. Description of Property: Legal HIDDEN RIVER PHASE ONE A PB 74 PG 101 LOT 100 Street Address: 3246 Moulden Hollow Drive Zephryhills FL 33541 2. General Description of Improvement Single Family Residence/Pool/Screen Enclosure/Fence 3. Owner Information: Lennar Homes, LLC. Name 4600 W Cypress St, Ste 200 Tampa . FL° 33607 Address City State Interest in Property: Name of Fee Simple Titleholder: N/A (If other than owner) Address City State 4. Contractor: Lennar Homes, LLC Name 4600 W Cypress St, Ste 200 Tampa FL, 33607 Address City State Contractor's Telephone No.: 813.574.5700 5. Surety: N/A Name Address City State Amount of Bond: $ Telephone No.: 6. Lender: N/A Name Address City State Lender's Telephone No.: 7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)(7),Florida Statutes: Lennar Homes. LLC Name 4600 W Cypress St, Ste 200 Tampa FL, 33607 Address City State Telephone Number of Designated Person: 813.574.5700 8. In addition to himself,the owner designates N/A of to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statutes. Telephone Number of Person or Entity Designated by Owner: 9. Expiration date of Notice of Commencement is one year from the date of recording unless a different date is specified: WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. STATE OF FLORIDA COUNTY OF PINELLAS Signature of caner or Owner's Authorized Officer/Director/Partner/Manager Vice President Signatory's Title/Office The foregoing instrument was acknowledged before me this 3 day of March by Steve Robert Smith as Vice President (type of autho' trustee,attorney in fact)for Lennar Homes LLC �parqtyowhom instrument was,executed). Personally Known R OR Produced Identification❑ Notary ignatu Type:of Identification Produced Name(Print) Elissa olleran Verification pursuant to Section 92.525,Florida Statutes. Under penalties.of perjury, I declare that I have read the foregoing and that the facts stated in it are true to,the best of my knowledge and belief. ELISSAM.HOLLERAN S gnature of Wural Person Signing Above CGMM118I0 0 FF 88583r Ex'Ires June li,2020 wpdata/bcs/bcs form; �''�P� 0ondelThmTroyFolnlnaunncelOO.3i5.70tD STATE OF FLORibA,COUNTY OF PASCO THIS IS TO CERTIFY THAT THE FOREGOING IS A TRUE AND CORRECT COPY OF THE DOCUMENT ON FILE OR OF PUBLIC RECORD IN THIS OFFICE WITNE WHANDANDDQqFFICIALSEALTHIS DAY OF 2 Die, ' In god^wi Trust PAULAS.O'NEIL,CLE K COMPTROLLER By_ DEPUTY CLERK 1887 8'13-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received Phone Contact for Permitting 813 363 _ 28=1 = I I I E 1 1 1 1 I I L 1 1 Owner's Name Lennar Homes,LLC Owner Phone Number r813.574.5700 Owner's Address 4600 W.Cypress St.Ste.200,Tampa,FL 33607 Owner Phone Number Fee Simple Titleholder Name I N/A Owner Phone Number Fee Simple Titleholder Address N/A JOB ADDRESS 3246 Moulden Hollow Drive LOT# 1000 SUBDIVISION Hidden River Phase One A PARCEL ID# 24-26-21-0060-00000-1000 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR e ADD/ALT SIGN DEMOLISH q INSTALL REPAIR PROPOSED USE u v u SFR Q COMM OTHER TYPE OF CONSTRUCTION 10 BLOCK Q FRAME STEEL DESCRIPTION OF WORK Single Family Residence/Pool/Screen Enclosure/Fence BUILDING SIZE I U/R SF 2376 SQ FOOTAGE 1936 HEIGHT 1 Story 10BUILDING $ UD VALUATION OF TOTAL CONSTRUCTION ELECTRICAL $ / ` AMP SERVICE ® PROGRESS ENERGY Q W.R.E.C:* � • Ltj PLUMBING $ MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION OGAS W1 ROOFING 0 SPECIALTY OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA DYES Flo BUILDER COMPANY Lennar Homes,LLC SIGNATURE _4REGISTERED Y/ N FEE CURREN Address 4600 W.Cypress St.Ste.20 ,Tampa,FL 33607 License# CGC1518166 ELECTRICIAN COMPANY =Edmonson Electric, Inc. SIGNATURE 4 REGISTERED Y/ N FEE CURREK Y/N Address 1034 Skipper Road, Tamp , FL 33613 License# EC13005408 . PLUMBER COMPANY Bayonet Plumbing, Heating &AC, Inc SIGNATURE _4REGISTERED Y/ N FEE CURREK Y/N Address P.O. Box 5308, Bayonet, FL 4674-5308 License# I CFC042998 MECHANICAL COMPANY Bayonet Plurribing, Heating & AC, Inc SIGNATURE . 4 REGISTERED Y/ N FEE CURREK I Y/N Address P.O. Box 5308, Bayonet, FL 4674-5308 License# I CAC058062 OTHER COMPANY SIGNATURE REGISTERED Y/ N FEE CURREK Y/,N Address 4211 Shoal Line Blvd, Spring Hi I, FL 34607 License# 1 CCC057991 IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIttlllllllllil RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. Directions: '^ L� Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500) ** Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACTIUTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 7-13, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I - certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the "owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner" prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify. that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone W" unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material ,is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90) consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR N ICE OF COMMENCEMENT. FLORIDA JURAT(F.S. 117.03) OWNER OR AGENT CONTRACTOR Subscribed and sworn to(or affirmed)be fo me this Subscribed and sworn to or affirmed)before me this UO-Mv-i i by Paul Sweeney03-Nov-1 by PauYSweeney Who is/are personally known to me or Who is/are personally I/nown to me or has/have pimedueed as en fication. as identification. Notary Public Notary Public Commission No. FF98537 Commission No. FF98537 Elissa M.Holleran Elissa M.Holleran Name of Notary tvr)ed,printed or stamped Name of Notary typed,printed or stamped GdlAslrvAPLUOUN. � �;q��mmrdh�amt�.hp�i�ep� ' �,l'�rrml�tan�ilfl�u6ee�� d��4`l�IPtlPabN',�Q�� � ��,�kigl�4lf_I�'2�d e�d.d�l�rr. w7d 4a�u�lla��,fill� &dW711NDV Fda tuowm4t4ai�,Tul! INSTR#2018048362 OR BK 9696 PG 3536 Page 1 of 4 03/22/2018 04:20 PM Rcpt 1942151 Rec:35.50 DS:646.80 IT:0.00 Paula S. O'Neil PCi.D., Pasco County CCerk&Comptroller This Instrument Was Prepared By And Should Be Returned To: Lee E.Nelson,Esq. Shutts&Bowen LLP 4301 W.Boy Scout Blvd.,Suite 300 Tampa,Florida 33607 Parcel Id Numbers: 24-26-21-0090-00000-0980;24-26-21-0090-00000-0990; 4-26-2�L0090 WO00-- 0060,-- ' SPECIAL WARRANTY DEED This Special Warranty Deed (this "Deed"), executed on this `day of .Cft�Cd 2018, by DUNE FL LAND I SUB LLC, a Delaware limited liability company ("Grantor"), whose mailing address is 2502 N. Rocky Point Drive, Suite 1050, Tampa, Florida 33607, to LENNAR HOMES, LLC, a Florida limited liability company ("Grantee"), whose mailing address is 4600 West Cypress Street, Suite 200,Tampa,Florida 33607. WITNESSETH: That Grantor, for and in consideration of the sum of ten dollars ($10.00) and other good and valuable consideration to Grantor in hand paid by Grantee, the receipt and sufficiency of which is hereby acknowledged, has granted, bargained, and sold to Grantee and Grantee's successors and assigns forever, the real property situate, lying, and being in Pasco County, Florida,and described in Exhibit"A"attached hereto(the"Property"). TOGETHER with all of the Grantor's rights, title and interest in and to all licenses, approvals, tenements,hereditaments, and appurtenances belonging or in any way appertaining to the Property. TO HAVE AND TO HOLD the same in fee simple forever. And Grantor hereby specially covenants with Grantee that Grantor is lawfully seized of the Property in fee simple, and hereby specially warrants the title to the Property and will defend the same against the lawful claims of all persons claiming by, through or under Grantor,but not otherwise, and that the Property is being conveyed to Grantee subject to all zoning and governmental regulations,all matters which a physical inspection of the Property would disclose, -and those permitted exceptions identified in Exhibit"B" attached hereto and made a part hereof, provided the foregoing shall not serve to reimpose the same. [SIGNATURE ON NEXT PAGE] OR BK 9696 PG 3537 Page 2 of 4 IN WITNESS WHEREOF, Grantor has executed this Deed on the date first above written. DUNE FL LAND I SUB LLC, a Delaware limited liabil - . mpany By: Signature of Witness 1 John M.Ryan,Manager Prin d Name of itnes Signature a Witness Printed 14ame of Witness 2 STATE OF FLORIDA ) ss.. COUNTY OF HILLSBOROUGH ) The foregoing instrument was acknowledged before me this day of , 2018, by John M. Ryan as Manager of DUNE FL LA,WD I SUB LLC, a Delaware limited liability company on behalf of the company, who is personally known to me or has produced _ for identifica 'o . otary Public My Commission Expires: S��a ,,.S;;�Y'a'••., KELLEY REMMEL a•• • `: •.e MY COMMISSION#GG 073177 EXPIRES:May 31 2021 •' ;o ° ' Bonded Thru NOWY Pdfic undwdem i 1 OR BK 9696 PG 3538 Page 3 of 4 Exhibit"A" Legal Description Lots 98,99 and 100,of HIDDEN RIVER PHASE ONE A, according to the Plat thereof, as recorded in Plat Book 74,Pages 101 through 121,inclusive,of the Public Records of Pasco County,Florida. i I I OR BK 9696 PG 3539 Page 4 of 4 Exhibit"B" Permitted Exceptions 1. Taxes and assessments for the year 2018 and subsequent years,which are not yet due and payable. 2. Restrictions, dedications, conditions,reservations, easements and other matters shown on the plat of HIDDEN RIVER PHASE ONE A, as recorded in Plat Book 74, Page(s) 101 through 121, inclusive, together with the Acknowledgement and Ratification of the Subdivision Plat of "Hidden River Phase One A"recorded in OR Book 9615,page 1267,both of the Public Records of Pasco County, Florida, but deleting any covenant, condition or restriction indicating a preference, limitation or discrimination based on race, color, religion, sex, handicap, familial status or national origin to the extent such covenants, conditions or restrictions violate 42 USC 3604(c). 3. Declaration of Covenants, Conditions and Restrictions for Hidden River Homeowners Association, Inc., which contains provisions for a private charge or assessments, including any amendments or modifications thereto,recorded in Official Records Book 9551, Page 3447, as affected by Agreement Regarding Authorized Builder Rights (Hidden River), recorded concurrently herewith, both of the Public Records of Pasco County, Florida but deleting any covenant, condition or restriction indicating a preference, limitation or discrimination based on race, color, religion;sex,handicap, familial status or national origin to the extent such covenants, conditions or restrictions violate 42 USC 3604(c). TPADOCS 21960153 128053.0256 Single F anvil Dwellin Y g Plan Review Comments 1. F.F.E. shall be aminimum:of.8",above,the road.elevation and an engineered,site plan. 2.. Lots shall be graded.to,comply with R401.3 of the F.B.C. 3. Compaction test required.if 24" or more.of .fill dirt is brought in at any one place: .4.. .Tie in survey required before pouring concrete.. 5.: Driveways require a R:O.W. use permit.. All 4 sides of driveway thru the sidewalk shall have expansion material.. 6.. All.setbacks shall be met.:.'. 7.. All property-markers-shall be.uncovered and marked.at time of first inspection: - 8:. All A.D.A. requirements shall be met. 9.. No:electric,plumbing,_mechanical, or framing shall be covered without an-inspection and approval first. 10. All.Garages shall comply:with.section R302Aofthe.F.B:C.:.(Fire-S:eparation). 11.Appliances shall not:be installed in.a location where subject-to mechanical damage unless protected by approved barriers: M303.4 of the F B.0 12. Water heaters shall.comply.with section P607.3 of the F.R.C. 13. Foundation supports for.A/C.units shall be raised at least 3" above finished grade,. M1308.1. 14. Return air in all,bedrooms..F.B.C. M1620.4. 15. Smoke detectors are.to be installed in-accordanee with.R313.1 of the F.B.C. .16.All glazing requirements are.to be'in accordance with R308.4,of the.F.B.C. 17. All means of egress are to be in:accordance with R311::of the R .C._ - 18. `.`Green gypsum board" shall not be used:as a backer in showers or tubs.R702.44.2 F.B.C. 19.'Combination-type AFCI breakers are required at all locations requiring an AFC type breaker: . . 20. Carbon monoxide.alarms will be required in new construetiori that uses fossil-burning heating :or appliances or an attached garage:. They shall be.installed in accordance with the F.B.C. 21._All plumbing,mechanical,:and-electrical shall be separate from unit.to.unit. This includes all underground plumbing and electric: 22."A112011.N.E.C. Codes:will be enforced: . 23.Tam er Resistant Receptacles' in accordance with 406.11 of the 201.1 N:E.0 p - � . . , . 24: Iri accordance.with the Land Development.Code; lots shall be sodded before final of least 10 ..feet around the structure: 25.A.cony of the energy Gaels shall be with permit at all times. 26 Copy ofrnal insulation report shall be.provided with permit.before finab F.F.E.=Finished Floor Elevation F:B.C=Florida Building Code 6h Edition R.O.W.-Right of Way A.D.A. Americans with.Disabilities Act N.E.C.-National Electric Code(2011): FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method 01010 Project Name: 1941 B sf ADS 3ton Builder Name: Lennar Homes Street: 3246 Moulden Hollow Drive Permit Office: City of Zphyrhills City,State,Zip: FL, Permit Number: Owner: Lennar Homes Jurisdiction: 611600 Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1961.3 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1454.60 ft2 b.Frame-Wood,Adjacent R=11.0 506.78 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (1936.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1936.00 ft2 6. Conditioned floor area above grade(ft2) 1936 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(157.3 sqft.) Description Area a.Sup:Attic,Ret:family rm,AH:laundry an 6 387.2 a. U-Factor. Dbl,U=0.54 101.00 ft2 SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.56 33.33 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 34.2 SEER:15.00 c. U-Factor: Dbi,U=0.56 23.00 ft2 SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 32.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 1.212 ft. Area Weighted Average SHGC: 0.308 14.Hot water systems 8. Floor Types (1936.0 sqft.) Insulation Area a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ft2 b. Conservation features EF:0.950 b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.081 Total Proposed Modified Loads: 62.94 PASS Total Baseline Loads: 62.65 I hereby certify that the plans and specifications covered by Review of the plans andTk�ST�g1, this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: Dave Aupich Before construction is completed r ' DATE: this building will be inspected for ;44�' - O compliance with Section 553.908 I herebycertify that this building,as designed, is in compliance Florida Statutes. fY 9� 9 P with the Florida Energy Code.. 00Zj � OWNER/AGENT: BUILDING O FICIAI41 DATE: i DATE: - - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house. 10/13/2017 1:21 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 6 FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method 01010 Project Name: 1941 B sf ADS 3ton Builder Name: Lennar Homes Street: 3246 Moulden Hollow Drive Permit Office: City of Zephyrhills City,State,Zip: FL, Permit Number: Owner. Lennar Homes Jurisdiction: 611600 Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1961.3 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1454.60 ft2 b.Frame-Wood,Adjacent R=11.0 506.78 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (1936.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1936.00 ft2 6. Conditioned floor area above grade(ft2) 1936 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(157.3 sqft.) Description Area a.Sup:Attic,Ret:family rm,AH:laundry rm 6 387.2 a. U-Factor: Dbl,U=0.54 101.00 ft2 SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.56 33.33 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 34.2 SEER:15.00 c. U-Factor: . Dbl,U=0.56 23.00 ft2 SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 32.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 1.212 ft. Area Weighted Average SHGC: 0.308 14.Hot water systems 8. Floor Types (1936.0 sqft.) Insulation Area a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ft2 b. Conservation features EF:0.950 b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.081 Total Proposed Modified Loads: 62.94 PASS Total Baseline Loads: 62.65 hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance i,,,''� `_= +• with the Florida Energy Code. PREPARED BY: Dave Aupich Before construction is completed DATE: this building will be inspected for 7 t7 compliance with Section 553.908 *, - I hereby certify that this building as g compliance designed, is in Florida Statutes. with the Florida Energy Code. G'Op yy �: OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: �� - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with Section 803 of RESNET Standards, is not greater than 0.030 Qn for whole house. 10/13/2017 1:21 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 6 FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 1941 B sf ADS 3ton Builder Name: Lennar Homes 010 Street: 3246 Moulden Hollow Drive Permit office: City of Zephyrhills City,State,Zip: FL, Permit Number: Owner: Lennar Homes Jurisdiction: 611600 Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1961.3 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1454.60 ft2 b.Frame-Wood,Adjacent R=11.0 506.78 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (1936.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1936.00 ft2 6. Conditioned floor area above grade(ft2) 1936 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ftz 11.Ducts R ft2 7. Windows(157.3 sqft.) Description Area a.Sup:Attic,Ret:family rm,AH:laundry rm 6 387.2 a. U-Factor: Dbl,U=0.54 101.00 ft2 SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.56 33.33 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 34.2 SEER:15.00 c. U-Factor: Dbl,U=0.56 23.00 ft2 SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 32.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 1.212 ft. Area Weighted Average SHGC: 0.308 14.Hot water systems 8. Floor Types (1936.0 sqft.) Insulation Area a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ft2 b. Conservation features EF:0.950 b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstaf Glass/Floor Area: 0.081 Total Proposed Modified Loads: 62.94 PASS Total Baseline Loads: 62.65 I hereby certify that the plans and specifications covered by Review of the plans and �Tk1EST,gT�- this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. ,./ PREPARED BY: Dave Mich Before construction is completed r� DATE: this building will be inspected for compliance with Section 553.908herebycertify that this building,as designed, is in compliance Florida Statutes. ;S fY 9� 9 P with the Florida Energy Code. Otj MAI- OWNER/AGENT: BUILDING OFF[ L: DATE: DATE: - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with Section 803 of RESNET Standards, is not greater than 0.030 Qn for whole house. 10/13/2017 1:21 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 6 FORM R405-2014 PROJECT Title: 1941 B sf ADS 3ton Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 1936 . Lot# Owner. Lennar Homes Total Stories: 1 Block/SubDivision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: Lennar Homes Rotate Angle: 45 Street: Permit Office: Cross Ventilation: No County: Pasco Jurisdiction: Whole House Fan: No City,State,Zip: Family Type: Single-family FL, New/Existing: New(From Plans) Comment: CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Tampa FL_TAMPA INTERNATI 2 39 91 70 75 645.5 54 Medium BLOCKS Number Name Area Volume 1 Entire House 1936 16360.3 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 master 210 1680 No 2 1 1 Yes Yes Yes 2 family rm 341 3171.3 No 0 1 Yes Yes Yes 3 cafe 161 1288 No 0 1 Yes Yes Yes 4 kit 182 1692.6 Yes 0 1 Yes Yes Yes 5 bdrm2 147 1176 No 1 1 1 Yes Yes Yes 6 bdrm3 149 1192 No 1 1 1 Yes Yes Yes 7 bath2 61 488 No 0 1 Yes Yes Yes 8 bdrm4 149 1192 No 1 1 1 Yes Yes Yes 9 o wic 104 832 No 0 1 Yes Yes Yes 10 privy 24 192 No 0 1 Yes Yes Yes 11 o bath 117 936 No 0 1 Yes Yes Yes 12 laundry rm 100 800 No 0 1 Yes Yes Yes 13 foyer 148 1376.4 No 0 1 Yes Yes Yes 14 hall 43 344 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio master 29.5 ft 0 212.3 ftZ 0 0 1 2 Slab-On-Grade Edge Insulatio family rm 14.5 ft 0 340.8 ftZ ___ 0 0 1 3 Slab-On-Grade Edge Insulatio cafe 25.5 ft 0 161 ft2 0 0 1 4 Slab-On-Grade Edge Insulatio kit 13.5 ft 0 182.3 ftZ 1 0 0 10/13/2017 1:21 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 6 FORM R405-2014 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 5 Slab-On-Grade Edge Insulatio bdrm2 10.5 ft 0 146.8 ft2 0 0 1 6 Slab-On-Grade Edge Insulatio bdrm3 13.5 ft 0 148.5 ft2 -__ 0 0 1 7 Slab-On-Grade Edge Insulatio bath2 5.5 ft 0 60.5 ft2 1 0 0 8 Slab-On-Grade Edge Insulatio bdrm4 35.5 ft 0 148.5 ft2 0 0 1 9 Slab-On-Grade Edge Insulatio o wic 21 ft 0 104 ft2 0 0 1 10SIab-On-Grade Edge Insulatio privy 1 ft 0 24 ft2 -__ 1 0 0 11Slab-On-Grade Edge Insulatio o bath 10.5 ft 0 117.3 ft2 ___ 1 0 0 12SIab-On-Grade Edge Insulatio laundry rm 9 ft 0 100 ft2 ____ 1 0 0 13SIab-On-Grade Edge Insulatio foyer 22.5 ft 0 147.5 ft2 1 0 0 14SIab-On-Grade Edge Insulatio hall 2 ft 0 42.5 ft2 0 0 1 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 2165 ft2 0 ft2 Medium 0.85 No 0.9 No 0 26.6 / ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 1936 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) master 30 Blown 210 ft2 0.1 Wood 2 Under Attic(Vented) family rm 30 Blown 341 ft2 0.1 Wood 3 Under Attic(Vented) cafe 30 Blown 161 ft2 0.1 Wood 4 Under Attic(Vented) kit 30 Blown 182 ft2 0.1 Wood 5 Under Attic(Vented) bdrm2 30 Blown 147 ft2 0.1 Wood 6 Under Attic(Vented) bdrm3 30 Blown 149 ft2 0.1 Wood 7 Under Attic(Vented) bath2 30 Blown 61 ft2 0.1 Wood 8 Under Attic(Vented) bdrm4 30 Blown 149 ft2 0.1 Wood 9 Under Attic(Vented) o wic 30 Blown 104 ft2 0.1 Wood 10 Under Attic(Vented) privy 30 Blown 24 ft2 0.1 Wood 11 Under Attic(Vented) o bath 30 Blown 117 ft2 0.1 Wood 12 Under Attic(Vented) laundry rm 30 Blown 100 ft2 0.1 Wood 13 Under Attic(Vented) foyer 30 Blown 148 ft2 0.1 Wood 14 Under Attic(Vented) hall 30 Blown 43 ft2 0.1 Wood 10/13/2017 1:21 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 6 FORM R405-2014 WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 S=>SW Exterior Concrete Block-Int Insul master 4.1 12 6 8 0 100.0 ft2 0 0 0.6 0 2 W=>NW Exterior Concrete Block-Int Insul master 4.1 17 0 8 0 136.0 ft2 0 0 0.6 0 3 S=>SW Exterior Concrete Block-Int Insul family rm 4.1 14 ;6 9 4 135.3 ft2 0 0 0.6 0 4 E=>SE Exterior Concrete Block-Int Insul cafe 4.1 12 0 8 0 96.0 ft2 0 0 0.6 0 5 S=>SW Exterior Concrete Block-Int Insul cafe 4.1 13 6 8 0 108.0 ft2 0 0 0.6 0 6 E=>SE Exterior Concrete Block-Int Insul kit 4.1 13 6 9 4 126.0 ft2 0 0 0.6 0 7 E=>SE Exterior Concrete Block-Int Insul bdrm2 4.1 10 6 8 0 84.0 ft2 0 0 0.6 0 8 E=>SE Exterior Concrete Block-Int Insul bdrm3 4.1 13 6 8 0 108.0 ft2 0 0 0.6 0 9 E=>SE Exterior Concrete Block-Int Insul bath2 4.1 5 6 8 0 44.0 ft2 0 0 0.6 0 10 N=>NE Exterior Concrete Block-Int Insul bdrm4 4.1 13 6 8 0 108.0 ft2 0 0 0.6 0 11 E=>SE Exterior Concrete Block-Int Insul bdrm4 4.1 11 0 8 0 88.0 ft2 0 0 0.6 0 12 W=>NW Exterior Concrete Block-Int Insul bdrm4 4.1 11 0 8 0 88.0 ft2 0 0 0.6 0 13 N=>NE Garage Frame-Wood o wic 11 28 4 8 0 226.7 ft2 0 0.25 0.01 0 14 W=>NW Exterior Concrete Block-Int Insul o wic 4.1 8 0 8 0 64.0 ft2 0 0 0.6 0 15 W=>NW Exterior Concrete Block-Int Insul o bath 4.1 10 6 8 0 84.0 ft2 0 0 0.6 0 16 N=>NE Garage Frame-Wood laundry rm 11 17 5 8 0 139.3 ft2 0 0.25 0.01 0 17 N=>NE Exterior Concrete Block-Int Insul foyer 4.1 5 0 9 4 46.7 ft2 0 0 0.6 0 18 W=>NW Garage Frame-Wood foyer 11 15 1 9 4 140.8 ft2 0 0.25 0.01 0 19 W=>NW Exterior Concrete Block-Int Insul foyer 4.1 2 5 9 4 22.6 ft2 0 0 0.6 0 _20 W=>NW Exterior Concrete Block-Int Insul hall 4.1 2 0 8 0 16.0 ft2 0 0 0.6 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N=>NE Wood laundry rm None .4 2 8 6 8 17.8 ft2 2 N=>NE Insulated foyer None .2 3 6 8 20 ft2 WINDOWS Orientation shown is the entered orientation(=>)changed to Worst Case. Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 S=>SW 1 Metal Low-E Double Yes 0.54 0.31 23.0 ft2 1 ft 0 in Oft 11 in None None 2 S=>SW 3 Metal 'Low-E Double Yes 0.54 0.31 46.0 ft2 1 ft 0 in Oft 11 in None None 3 S=>SW 5 Metal Low-E Double Yes 0.56 0.32 33.3 ft2 2 ft 0 in 0 ft 4 in None None 4 E=>SE 7 Metal Low-E Double Yes 0.54 0.31 16.0 ft2 1 ft 0 in Oft 11 in None None 5 E=>SE 8 Metal Low-E Double Yes 0.54 0.31 16.0 ft2 1 ft 0 in Oft 11 in None None 6 N=>NE 10 Metal Low-E Double Yes 0.56 0.28 23.0 ft2 1 ft 0 in Oft 11 in None None 10/13/2017 1:21 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 6 r FORM R405-2014 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 416ft2 416ft2 43.7ft 8ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000376 1908.7 104.79 197.06 .2819 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump Split HSPF:8.5 32.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER:15 34.2 kBtu/hr 1026 cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 40 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS —Supply— —Return— Air CFM 25 CFM25 HVAC# # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 387.2 ft family rm 96.8 ft2 Proposed Qn laundry rm —cfm 58.1 cfm 0.03 0.50 1 1 10/13/2017 1:21 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 6 , . . . . - [ / ' 10x3/20 71:2nPm EnargyGougn@ USA'RaRouuO4 Section n4o5�.1 Compliant 8omwoe Page eu[a FORM 13405-2094 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerformance Index, the more efficient the home. FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1454.60 ftz b.Frame-Wood,Adjacent R=11.0 506.78 ft 3. Number of units,if multiple family 1 c.N/A R= ftZ 4. Number of Bedrooms 4 d.N/A R= ftZ 10.Ceiling Types Insulation Area 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1936.00 ftZ 6. Conditioned.floor area(ftZ) 1936 b.N/A R= ftZ 7. Windows" Description Area c.N/A R= ftZ a. U-Factor: Dbl,U=0.54 101.00 ftZ 11.Ducts R ftZ a.Sup:Attic,Ret:family rm,AH:laundry rm 6 387.2 SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.56 33.33 ftZ SHGC: SHGC=0.32 12.Cooling systems kBtu/hr Efficiency c. U-Factor: Dbl,U=0.56 23.00 ftZ a.Central Unit 34.2 SEER:15.00 SHGC: SHGC=0.28 d. U-Factor: N/A ftZ 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 32.8 HSPF:8.50 Area Weighted Average Overhang Depth: 1.212 ft. Area Weighted Average SHGC: 0.308 8. Floor Types Insulation Area 14.Hot water systems a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ftZ EF:0.95 b.N/A R= ftZ c.N/A R= ftZ b. Conservation features None 15.Credits Pstat certify that this home has complied with the Florida Energy Efficiency Code for Building SHE ST Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed ',;-`'�� ?.• ';�. based on installed Code compliant feature Builder Signature: Date: 11/08/17 Address of New Home: 3246 Mo en Hollow Drive City/FL Zip:Zephyrhills,FL 33540 *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 10/13/2017 1:22 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 r ' Buildin Anal SIS Job: 1941BsfADS 9 y Date: 10130/2017 Entire House By: Dave Bayonet Plumbing Heating and Air Project I • • For: Lennar Homes Design Conditions Location: Indoor: Heating Cooling Tampa International AP, FL, US Indoor temperature(°F) 70 75 Elevation: 10 ft Design TD (°F) 39 16 Latitude: 28°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 34.7 54.7 Dry bulb(°F) 31 91 Infiltration: Daily range(°F) - 14 ( L ) Method Simplified Wet bulb(°F) - 77 Construction quality Semi-tight Wind speed(mph) 15.0 7.5 Fireplaces 0 • Component Btuh/ftZ Btuh % of load Walls 5.6 7025 24.5 Ducts Glazing 30.2 4763 16.6 W10ther Doors 23.5 466 1.6 nfiltration Ceilings 1.3 2429 8.5 Floors 3.5 6726 23.5 Infiltration 2.8 3996 14.0 Ducts 3223 11.3 Piping 0 0 Glazing Humidification 0 0 F'°°`s Ventilation 0 0 ilin Adjustments 0 Total 28628 100.0 Fero In • Component Btuh/ftZ Btuh % of load Walls 2.8 3495 13.4 Walls Glazing 56.8 8959 34.4 Internal Gains Doors 18.4 365 1.4 Ceilings 1.7 3358 12.9 Floors 0 0 0 Infiltration 0.6 880 3.4 ' Ducts 3621 13.9 ucts Ventilation 0 0 Glazing Internal gains 5340 20.5 Blower 0 0 Infiltration Adjustments 0 Total 1 1260171 100.0 Other Ceilings Latent Cooling Load=4071 Btuh Overall U-value= 0.103 Btuh/ftZ-°F Data entries checked. ._ + wrightsoft® 2017-Oct-30 09:03:17 MCA Right-Suite®Universal 2017 17.0.23 RSU05714 Page 1 ...th CBA27UHE AH's11941B sf ADS template 3ton.rup Calc=MJ8 Front Door faces: W Project Summary Job: 1941B sf ADS Date: 10130I2017 Entire House By: Dave Bayonet Plumbing Heating and Air Project Information For: Lennar Homes Notes: 2017 Design Information Weather: Tampa International AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 31 °F Outside db 91 °F Inside db 70 °F Inside db 75 °F Design TD 39 °F Design TD 16 °F Daily range L Relative humidity 50 % Moisture difference 55 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 25405 Btuh Structure 22396 Btuh Ducts 3223 Btuh Ducts 3621 Btuh Central vent(0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 28628 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 26017 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 3425 Btuh Ducts 646 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling (none) Area(ft2) 1936 1936 Equipment latent load 4071 Btuh Volume ft') 16360 16360 Air changes/hour 0.34 0.18 Equipment Total Load (Sen+Lat) 30088 Btuh Equiv.AVF(cfm) 93 49 Req. total capacity at 0.85 SHR 2.6 ton Heating Equipment Summary Cooling Equipment Summary Make Lennox Make Lennox Trade 14HPX SERIES Trade 14HPX SERIES Model 14HPX-036-230-21 Cond 14HPX-036-230-21 AHRI ref 10258589 Coil CBA27UHE-036-230*++TDR AHRI ref 10258589 Efficiency 8.5 HSPF Efficiency 12.5 EER, 15 SEER Heating input Sensible cooling 29580 Btuh Heating output 32800 Btuh @ 47°F Latent cooling 5220 Btuh Temperature rise 25 °F Total cooling 34800 Btuh Actual air flow 1200 cfm Actual air flow 1200 cfm Air flow factor 0.042 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.86 Capacity balance point=29°F Backup: n/a n/a Input= 0 kW, Output=0 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. ^t wrightsoftm 2017-Oct-30 09:03:17 Right-Suite®Universal 2017 17.0.23 RSU05714 Page 1 14( ...th CBA27UHE AH's11941 B sf ADS template 3ton.rup Calc=MJ8 Front Door faces: W Manual S Compliance Report Job: 1941 B sf ADS Date: 1 013 0/2 01 7 Entire House By: Dave Bayonet Plumbing Heating and Air Project Information For: Lennar Homes Cooling Equipment Design Conditions Outdoor design DB: 91.3°F Sensible gain: 26017 Btuh Entering coil DB: 75.6°F Outdoor design WB: 77.3°F Latent gain: 4071 Btuh Entering coil WB: 62.8°F Indoor design DB: 75.0*F Total gain: 30088 Btuh Indoor RH: 50% Estimated airflow: 1200 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASH P Manufacturer: Lennox Model: 14HPX-036-230-21+CBA27UHE-036-230*++TDR Actual airflow: 1200 cfm Sensible capacity: 29070 Btuh 112% of load Latent capacity: 5130 Btuh 126%of load Total capacity: 34200 Btuh 114%of load SHR: 85% Heating Equipment Design Conditions Outdoor design DB: 30.8°F Heat loss: 28628 Btuh Entering coil DB: 69.7°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Lennox Model: 14HPX-036-230-21+CBA27UHE-036-230*++TDR Actual airflow: 1200 cfm Output capacity: 32800 Btuh 115% of load Capacity balance: 29 OF Supplemental heat required: 0 Btuh Economic balance: -99 OF Backup equipment type: Elec strip Manufacturer: n/a Model: n/a+n/a Actual airflow: 1200 cfm Output capacity: 0 kW 0% of load Temp. rise: 0 OF Meets are all requirements of ACCA Manual S. 2017-Oct-30 09:03:17 wrightSloft' Right-Sufte(D Universal 2017 17.0.23 RSU05714 Page I ...th CBA27UHE AH'skI9418 sf ADS template 3ton.rup Calc=MJ8 Front Door faces: W .... ................ ...... ------ -v 03 CD EC via 1;,I* J 11A �1. f V Il 11-9 9-1 ............... ....... ... .... ... . .... .... ..... .. .. ......... 15 .............. .. ..... ................ ...... .. . ............. ..... ........... .... ...... ...... -------MVE--- ...... MOULDEN Ho .............................. ........... ....... . .. . ....... . .......... .. .......... .. ...... r'Ir"� �'�' � '� � I � I J � � � 1 E � � t t �''� � I ! " '°`� p �l ! �: � �` t I �`.� � J 1 a CYJ -c - I to C4 1 CD CO co cn 'Aw Yw- .. ... ........ .... ... .... t IA I I J I o 1 11 (4- CD f -.4 tyl ..IS,l co I f i .,, j �' I I I ! 1 1 I I �-� ! t I J �- I ! I -�n-n is p Y r PASCO COUNTY, FLORIDA t Permit No. Date Permitted --3—t LLC Builder Name/Owner Name Control#' . County Parcel No. 2 ' ?�--- (� (�{�(�(�•�t-rSt lbDiv: Address/Location b2A Classification(Type of Use TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: 2r 37i Exempt ❑1 Yes [] No How Determined Impact Fee Amount $. , >-2- Zone No. TAZ: SCHOOL IMPACT FEE Account (056) Single-Family Detached House Amount $ �F 8 Z L (057) Mobile Home (058) Other Residential 123) Collection_Fee Exempt Yes ❑No How Determined PARKS AND RECREATION FEE Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation Total Zone TOTAL AMOUNT $ Z Exempt ❑Yes ❑ No How Determined LIBRARY FEE Land Account Land Credit Land Total Facility Account Facility Credit Facility Total Exempt ❑Yes ❑ No How Determined Total Amoun� RESOURCE FEE ERU TOTAL AMOUNT Prepared By Checked By CT- NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY Acknowledgement below does not imply acceptance of concurrence,but simply receipt of-a copy of this form,placing the building permit owner on notice of this assessment and the conditions of payment for same. DATE RECEIVED BY RECEIPT NO. DATE BY 5335 - 8TH STREET (813)780-0020 CERTIFICATE OF OCCUPANCY Address: 3246 MOULDEN HOLLOW DR Owner: LENNAR HOMES LLC ZEPHYRHILLS, FL. 4600 W CYPRESS ST STE 200 Subdiv: SILVERADO TAMPA FL 33607 Parcel: 24-26-21-0060-00000-1000 Work Type: 101-NEW CONST/SFR Construction Type: NOT APPLICABLE ❑ Sprinklers Use Classification: NOT APPLICABLE Permit Number: 19517 D te: C,�� e 7/18/2018 ISSUED' Y: BUILDI OFFICIAL WATER MUST BE CHANGED OVER WITHIN 10 DAYS OF ISSUANCE GARBAGE DEPOSIT MUST BE APPLIED FOR PRIOR TO ISSUANCE