HomeMy WebLinkAbout18-19518 CITY OF ZEPHYRHILLS
J 5335-8TH STREET_
` f813h80-0620 _ 19518
BUILDING PERMIT SINGLE,FAMILY RESIDENTIAL
PERMIT INFORMATION LOCATION,INFORMATION
Permit#:19518 Issued: 4/03/2018 Address: 3258 MOULDEN HOLLOW DR
Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. f
Class of Work: 101-NEW CONST/SFR T. hip: Range: r'
Proposed Use: NOT APPLICABLE Lot(s) Block: Section'.
Sq. Feet: Est. Value: Book: Page: 1'
Cost: 256,391.40 Total Fees: 14,474.47 Subdivision: HIDDEN RIVER
Amount Paid: 14,474.47 Date Paid: 4/03/2018 Parcel Number: 24-26-21-0060-0000-0990
CONTRACTOR INFORMATION OWNER INFORMATION
Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC
Addr: 4600 W. CYPRESS ST STE 200 Address: 4600 W. CYPRESS ST STE 200
TAMPA, FL. 33607 TAMPA FL 33607
Phone: (813)574-5743 Lic: Phone:
Work Desc: CONSTRUCT SINGLE FAMILY 2,276 SQ FT
APPLICATION FEES
BUILDING FEE 1,058.17 ELECTRICAL FEE- 215.78 PLUMBING FEE 443.85
MECHANICAL FEE 100.70 SEWER CONNECTION RESIDEW 2,010.00 WATER CONNECTION RESIDENI 641.00
WATER METER RES 3/4" 473.78 PARK FEES SF 769.56 SCHOOL IMPACT FEE-sfr/100% 4,828.00
SCHOOL IMPACT FEE-sfr/1% 48.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32
POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35
Inspections Required
FOO ER 2ND ROUGH PLUMB MISC INSULATION CEILING
FOOTER BOND DUCTS INSULATED SEWER MISC.
ROUGH ELECTRIC LINTEL MISC MISC.
1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC.
DUCTS INSTALLED WATER MISC DRIVEWAY
PRE-SLAB SHEATHING MISC. MISC.
CONSTRUCTION POLE FRAME MISC. MISC.
REINSPECTION FEES: (c)With respect to Reinspection fees Will comply with Florida Statute 553.80 (2)(c)the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES:
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing,.consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance
with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
JA &k0_7-
S SIGNATURE PERMIT OFFI
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
INSTR#2018048362 OR BK 9696 PG 3536 Page 1 of
03/22/2018 04:20 PM Ropt:1942151 Reo:35.50 IDS:646.80 IT:0.00
Paula S.O'Neil Ph.D., Pasco county clerk&comptrotTer
This Instrument Was Prepared
By And Should Be Returned To:
Lee E.Nelson,Esq.
Shutts&Bowen LLP s
4301 W.Boy Scout Blvd.,Suite 300
Tampa,Florida 33607
Parcel Id Numbers: 24-26-21-0090-00000-0980;24-26-21-0090-00000-0990;24-26-21-0090-00000-1000
SPECIAL WARRANTY DEED
This Special Warranty Deed (this "Deed"), executed on thiso--1 of .Cfele—l\
2018, by DUNE FL LAND I SUB LLC, a Delaware limited liability company ("Grantor"),
whose mailing address is 2502 N. Rocky Point Drive, Suite 1050, Tampa, Florida 33607, to
LENNAR HOMES, LLC, a Florida limited liability company ("Grantee"), whose mailing
address is 4600 Vest.Cypress Street, Suite 200,Tampa,Florida 33607.
WITNESSETH:
That Grantor, for and in consideration of the sum of ten dollars ($10.00) and other good
and valuable consideration to Grantor in hand paid by Grantee, the receipt and sufficiency of
which is hereby acknowledged, has granted, bargained, and sold_to Grantee and Grantee's
successors and assigns forever, the real property situate, lying, and being in Pasco County,
Florida,and described in Exhibit"A"attached hereto(the"Property").
TOGETHER with all of the Grantor's rights, title and interest in and to all licenses,
approvals,tenements,hereditaments, and appurtenances belonging or in any way appertaining to
the Property.
TO HAVE AND TO HOLD the same in fee simple forever.
And Grantor hereby specially covenants with Grantee that Grantor is lawfully seized of
the Property in fee simple, and hereby specially warrants the title to the Property and will defend
the same against the lawful claims of all persons claiming by, through or under Grantor,but not
otherwise, and that the Property is being conveyed to Grantee subject to all zoning and
governmental regulations, all matters which a physical inspection of the Property would disclose,
and those permitted exceptions identified in Exhibit"B" attached hereto and made a part hereof,
provided the foregoing shall not serve to reimpose the same.
[SIGNATURE ON NEXT PAGE]
OR BK 9696 PG 3537 Page 2 of 4
IN WITNESS WHEREOF, Grantor has executed this Deed on the date first above
written.
DUNE FL LAND I SUB LLC, a Delaware limited
liabil -. mpany
By:
Signature of Witness 1 John M.Ryan,Manager
P=dN of itnes
Signature Witness
Printed 14ame of Witness 2
STATE OF FLORIDA )
ss.:
COUNTY OF HILLSBOROUGH )
The foregoing instrument was acknowledged before me this day of�ll�'
2018, by John M. Ryan as Manager of DUNE FL LAND I SUB LLC, a Delaware limited
liability company on behalf of the company, who is personally known to me or U has
produced _ for identifica •o .
• otary Public
My Commission Expires: 5��9
KELLEY REMMEL
*= MY COMMISSION#GG 073177
EXPIRES:May 31,2021
ThN No Public U'derwriierc
Balled 1aTY
I
OR BK 9696 PG 3538'• Page 3 of 4
Exhibit"A"
Legal Description
Lots 98,99 and 100,of HIDDEN RIVER PHASE ONE A, according to the Plat thereof,as
recorded in Plat Book 74,Pages 101 through 121,inclusive,of the Public Records of Pasco
County,Florida.
i
OR BK9696 Pr.3539 Page 4 of 4
Exhibit"B"
Permitted Exceptions
L Taxes and assessments for the year 2018 and subsequent years,which are not yet due and
payable.
2. Restrictions, dedications, conditions,reservations, easements and other matters shown on
the plat of HIDDEN RIVER PHASE ONE A, as recorded in Plat Book 74, Page(s) 101 through
121, inclusive, together with the Acknowledgement and Ratification of the Subdivision Plat of
"Hidden River Phase One A"recorded in OR Book 9615,page 1267,both of the Public Records
of Pasco County, Florida, but deleting any covenant, condition or restriction indicating a
preference, limitation or discrimination based on race, color, religion, sex, handicap, familial
status or national origin to the extent such covenants, conditions or restrictions violate 42 USC
3604(c).
3. Declaration of Covenants, Conditions and Restrictions for Hidden River Homeowners
Association, Inc., which contains provisions for a private charge or assessments, including any
amendments or modifications thereto,recorded in Official Records Book 9551, Page 3447, as
affected by Agreement Regarding Authorized Builder Rights (Hidden River), recorded
concurrently herewith, both of the Public Records of Pasco County, Florida but deleting any
covenant, condition or restriction indicating a preference, limitation or discrimination based on
race, color,religion;sex,handicap,familial status or national origin to the extent such covenants,
conditions or restrictions violate 42 USC 3604(c).
TPADOCS 21960153 128053.0256
Jacqueling Boges
From: TQ Randolph (City of Zephyrhills Support)<support@zephyrhillsfl.zendesk.com>
Sent: Wednesday,April 4, 2018 11:30 AM
To: Jacqueline Boges
Subject: [FATHOM] Re: 3258 Moulden Hollow Dr
##-Please type your reply above this line-44
Your request #2( 05735)has been updated.REPLY TO THIS EMAIL or click the link below:
https://zMhyrhillsfl.zendesk.com/hg/requests/205735
.......................................................................................:.........................................................................................................................................................................................................................................................:..................................
...
TQ Randolph(City of Zephyrhills Support)
Apr 4, 8:29 AM MST
Account has been created. 889145-2987449.
Service order will be created once location is mapped by our GIS team.
Best Regards,
TQ1 FATHOM Support
................................................................................................_.................................................................................................................................................................................................................................................................................
1-' Jacqueline Boges
»I Apr 3, 12:32 PM MST
full service new for 3258 Moulden hollow Dr water, sewer, water meter
This email is a service fi•om City of Zephyrhills Support.
i
1
Lennar Homes-3258 Moulden Hollow Dr-2,276 sq ft
o umn ts
SQ. FEET PRICE
MAIN OR LIVING: 2,276 $ 112.65
OTHER AREA UNDER ROOF: - $ 88.00
OTHER: - $ -
VALUATION $ 256,391.40
FEE SHEET $ 959.00
ADDRESS $ 40.00
DRIVEWAY $ 40.00
BUILDING: $ 1,058.18
ELECTRICAL: $ 215.78
PLUMBING: $ 143.85
MECHANICAL: $ 100.70
SUB-TOTAL $ 1,518.50
TOTAL $ 1,518.50
SEWER: $ 2,010.00
WATER: $ 641.00
IRRIGATION: $ -
TOTAL: $ 2,651.00
WATER METER:1 $ 473.78
IRRIGATION METER $ -
FIRE DEPARTMENT FEES
PLANS TOTAL: n/a
INSPECTION TOTAL:
PERMIT TOTAL
TOTAL: $ -
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
FIRE $ 273.00
5% $ 26.35
TOTAL: $ 553.35
�I
SUB-TOTAL $ 5,196.63
PARK IMPACT FEES $ 769.56
i
SIF'S: $ 4,828.00
100.0% $ 4,828.00
1.0% $ 48.28
TOTAL: $ 4,876.28
T I F'S: $ 3,632.00
99% $ 3,595.68
1% $ 36.32
TOTAL: $ 14,474.47
?`
l,.ij� •�- Ale
City of Zephyrhills �=
BUILDING PLAN REVIEW COMMENTS .
Contractor/Homeowner: 6--�,v �►" L "r�
Date Received:
Site: C��
Permit Type:
Approved w/no comments:❑ Approved w/the below comments: Denied w/the below comments: ❑
This.comment sheet shall be kept with the permit and/or plans.
Kalvin w' r—Plans Examiner Date Contractor and/or Homeowner
(Required when comments are present).
PS
Jwt Stream,
Ili �►� � Inball �IQ ti 1 1.1 ii rr. 7'I t ..r lid �rw P,IrF'rt�
C'Wd I 1 L i I; I�_�
r � .♦+ia.+►IYM RI♦ .�,-sw N M'f-' r aI'�' ~ -•� 't
-•�.-Ira i• F • �'- + -„� . . -.� i•+ar tl•,!1•Y •,�►yr ` �� _
n.:.l..P—T �"`K''�lwa ti.nw■1 Ms.F'Jor=.rw I(l++M� ...r•.r-_ - - .., _ .�.. - -
ry!r +a..r,c•Y+v.�...:.1 !_ar �,F�•r� a •�1 n` a• _ _ _. al _ " -.i • �.
A ri.Fl ai ia��Mtrl vrrl ..•4.1 t+.•.r+ ►1•rn rf' .r,,.A.i d -. .. - - __ __ .
so"pw KAMME. ��IS1►..wr!
N 1 '' MI�11' •r�.r..ram, c*.ww!it
twM+�f� , w 1 iiF.��1.., Ut,�,r 4- rid a�W
4 NL ���4r, I .r.r i •w�wFhM.. + ri�*'i r
/ is �IFMf'� 1�•.r fi am i•i
N'•� .~•-1 1 I ' ' t 1l�C.1 � �a.M+•� SIF^7 � +
N •� 1 .S ,rn ti N y. 1 1 1>• ,iar.
rA I+arN f t+1K.y �.+•,�: —
••••.1+ +.. ..s.- _ _ . .c•1.. .... uVolowilan
i +r'•t tl l t� .R.Jpls wl• IM k "' '
from" 3f Uwe"" iFi+iiM iin1�� riltl�arr=.
}
4 .r,,oou•.►►.y. .. , ...r.- I w1:« �-q"w al /y loo-Ob'y
'•'.M.:1 r•r.,, re I,a..,. i. .v MI H♦u'r1Yrir �`Yilw� . •1,filar rr. ry r ,rrPrw•_ .4 r AN."E+i 406 1*- wr—we W-F i 1
�N+ w.�•lrr dr M MOP
we c ar a '! ,_.t•a ' ,., ++a ti ' _
1140" Owlr+w �rrw� I►aMli cp fIQ ee
1 g -
11 p, r r-,I�'T I _ a 1-
.,a �ni
a.
�'.� 1 :art 171 �.wr...,��.-. .,..r.�:..�+r■.. ...._._ . _ . _ _ ,_. . .� ._ ,
141
1IIkSY�> r',E2a1t1a11MM ,
! °'!! I1:+ LI N" 1'�4 tr��rat�R7�;rIIt1�VC1 PC Tr,r=L}+�
j►R
T �rl t v I, � v9 � � II�Mr�' 1►•1�>�I��
, i 1 Mills ; -- — - - -
R• � _•7Nf � t r•+ F ta.rll •:M1
ii ,0 'ts
CAM hVidrd
II 3y_' 48 _ d,y �1.,rn�lsd�,+�+�*t-ae tl+e� �0�4 r r-• •:t •�',f•r�+c+:,t•'••:•:a 1,:.�u �:y,.,.;A r 1,•: 'Wig&,:a g. z,.t.ri't l• ..St�I i .:r `rr1 ...�I
�11 )IA Ar AWr•W.lr a'+'t1 J
1■i � 31♦ 1 !E
G. M +ff Ii7F�A�•!II:tMb-wt+ i Y+rr"aal
"yttFii i�,nY rl
t '
PAS,C
I !i eT'1
! f� II " I i. h�;4,II l! ,i'. :��1�owe o IoIIf
7 FT_�i9'ISi=w A I�'e'7 i Z r�I
1076
Ij :. ='1:� �kiii , d�urllh"kt? 61 11`11k' iti [,f,ESfj�:w riilll l rs><�ntlIIiif:Al ISM `a►3{trfil 140; •i I =�
1Frrliy. i tJ*-,rJigW IeRI{ f._411,;!<_;.si��6jars.'I'tiri-l�.R%fl��.r�; _ _._ 4 .age T
� i I� Y9 � Fop;'S� ��,i'R�-f31ILFf�, _
�sn ku Fa�ittli +tSLlI hs'� :r�tili+:l :.� :t W$ar, "h6, ul u �+rS: sA'[6:!hnL7 �_ �T,
IAr kkuklu l'iMi. 64 I. i+iM ;Miff h 'k:k:�gjN-i �i MM APPICnAA third pwft � A. skiMM 9,VWLuf i�I' Ir�uli nrF 1� Eti�
%h.& i N 'a1&l"l hi'F}'I:'41MAk h!T••�.,�1 =i Ih--I.,�1'1 ki:••I�tf(,:4.p'- 1 I°4 ww 1 l 11 rK 1�§ii�tS��if'lili Ebstil:st.i' C}'��ji;7i1: tiKli' to `
q t�'1#.,ai +I'1 f4:;q«,•..y uyvuir+ fh..,r;: a ;[Lill icrry f s w'.i H-,- t r-.kffivi k sl'. ll''w_f trar4� �1 i�ff-!Or* r-nib.I
I
i.3,c'!u L'is�•I�carizal c�,t ri(�;e.• I
f tRr�PrTIlf 'irF,i[
�'!'■iwl�aw iwv+litsw3 jr�il•�ksi►y,Peiy�is R,iifall''ili.�ik�l+'ti Rim RFr'q`icr :,.le3r+1 r±:r+i; rid,I
''�` rl� i��•9d1yc" I
I
D-%;.p .tnc in,trW iri3ytst'J. lqij's*.im"r L p i x,,hariiittt'.-h-aeod War ijar=oivf,i fL A'bo ifini.i�y„hi rV A 'i_i OF
I
�/t!<itr-iwl)N'rj't1Lri(ESr'
�1i1[�rMui' Iw ki'itrti fullk3f,r1'EF�r Irlr>l til +J�i+i! Li►FA 11Fi+fif
��111rrQ1 3•fco EMrMMxvvL Wnt-Ai4on-IV-Arm Mid NIA rwarr-q 4rtfTCd4i:gg'6%f• Ibr LJ[3�;ma viko j
f Flkp Wq#40 CQG+"11'i'Airm-fill MWRLftldl at IfCW I!M fd%1*OK be Rwff/SIC
y, �'''rS •,ram►"lflr'r:r�rttl�I�,rif rt`il sti,a+��e tf�#�1�e+��'�i'ts'I:��i'6+�i'bi'F�ray �
'fie` I
I
' v il�tgllrtltt` botum(fillAtfive
'
I
U+tr Z rof] k _ II 5 T A CH* (5 0 A C'H A�iwtAll � f
4pw 0
CkU&&' Aur nxkhz jy inkvdtpcgd Att sib(k= AC1 l)
� ��'s �• ��3P thr vj�xakr ri4vr I
40 xw ume BSc i
I
Jacqueline Boges
From: City of Zephyrhills Support<support@zephyrhillsfl.zendesk.com>
Sent: Wednesday, April 25, 2018 7:01 PM
To: Jacqueline Boges
Subject: Request#205735: How would you rate--the,support you received?
##- Please type your reply above this line -## /
Hello Jacqueline Boges, (((
We'd love to hear what you think of our customer service. Please take a moment to answer one simple question by
clicking either link below:
Flow would you rate the support you received?
Good. I'm satisfied
Bad. I'm unsatisfied
Here's a reminder of what your ticket was about:
..................................................................................................................................................................................................................................................................................................................................................................................
". TQ Randolph (City of Zephyrhills Support )
[ Apr 24, 3:29 PM MST
Complete. 889145-2987449, SO# 667382
Best Regards,
TQI FATHOM Support
.......................................................................................................................................................................................................................................................................................................................................................................................
TQ Randolph (City of Zephyrhills Support )
- Apr 4, 8:29 AM MST
Account has been created. 889145-2987449.
Service order will be created once location is mapped by our GIS team.
Best Regards,
TQI FATHOM Support
....................................................................................................................................................................................................................................................................................................................................................................................
Jacqueline Boges
1
�
' ......................... ............_.........................
. `
Apr3. 12:32 PM MST
full service D r
This email isa service from City ofZmphyrhiUs Support
.
�
�
. }
'
'
2
Jacqueline Boges
From: TQ Randolph (City of Zephyrhills Support)<support@zephyrhillsfl.zendesk.com>
Sent: Tuesday, April 24, 2018 6:30 PM
To: Jacqueline Boges
Subject: [FATHOM] Re: 3258 Moulden Hollow Dr
##- Please type your reply above this line -##
Your request (#205735) has been solved. TO REOPEN THIS REQUEST, reply to this email or click the link below:
https://zephyrhilisfl.zendesk.com/hc/requests/205735
.....................................................................................................................................................................................................................................................................................................................................................................................
TQ Randolph (City of Zephyrhills Support )
-'`—' Apr 24, 3:29 PM MST
Complete. 889145-2987449, SO# 667382
Best Regards,
TQ1 FATHOM Support
.......................................................................................................................................................................................................................................................................................................................................................................................
TQ Randolph (City of Zephyrhills Support )
�--- Apr 4, 8:29 AM MST
Account has been created. 889145-2987449.
Service order will be created once location is mapped by our CIS team.
Best Regards,
TQ1 FATHOM Support
.......................................................................................................................................................................................................................................................................................................................................................................................
- Jacqueline Boges
- Apr 3, 12:32 PM MST
full service new for 3258 Moulden hollow Dr water, sewer, water meter
This email is a service from City of Zephyrhills Support .
i
Jacqueline Boges
From: City of Zephyrhills Support<support@zephyrhillsfl.zendesk.com>
Sent: Tuesday, April 3, 2018 3:32 PM
To: Jacqueline Boges
Subject: [Request received] 3258 Moulden Hollow Dr
##- Please type your reply above this line -##
Hello Jacqueline Boges,
We are working to resolve your request promptly and will keep you updated. One of our Support Analysts will keep
you updated on the progress of your request.
Best Regards,
FATHOM Support Team
TO ADD ADDITIONAL COMMENTS, reply to this email or click the link below:
https://zephyrhillsfi.zendesk.com/hc/requests/205735
.......................................................................................................................................................................................................................................................................................................................................................................................
r I Jacqueline Boges
Apr 3, 12:32 PM MST
full service new for 3258 Moulden hollow Dr water, sewer, water meter
This email is a service from City of Zephyrhills Support .
1
2018053282
Rcpt:1944465 Rec: 10.00
DS: 0.00 IT: 0.00
04/02/2018 K. A. , Dpty Clerk
PAULA S.0'NEIL,Ph.D.PASCO CLERK 8& COPIPTROLLEh
04 R2BK701 19 m PG 220
Permit No. Parcel ID No 24-26-21-0060-00000-0990
NOTICE OF COMMENCEMENT
State of Florida County of Pasco
THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 713,Florida Statutes,
the following information is provided in this Notice of Commencement:
1. Description of Property: Legal HIDDEN RIVER PHASE ONE A PB 74 PG 101 LOT 99
Street Address: 3258 Moulden Hollow Drive Zephryhills FL 33541
2. General Description of Improvement Single Family Residence/Pool/Screen Enclosure/Fence
3. Owner Information:- Lennar Homes, LLC.
Name
4600 W Cypress St. Ste 200 Tampa FL. 33607
Address City State
Interest in Property:
Name of Fee Simple Titleholder: NSA
(If other than owner)
Address City State
4. Contractor: Lennar Homes, LLC
Name
4600 W Cypress St, Ste 200 Tampa FL, 33607
Address City State
Contractor's Telephone No.: 813.574.5700
5. Surety: N/A
Name
Address City State
Amount of Bond: $ Telephone No.:
6. Lender: NSA
Name
Address City State
Lender's Telephone No.:
7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by
Section 713.13(1)(a)(7),Florida Statutes:
Lennar Homes, LLC
Name
4600 W Cypress St, Ste 200 Tampa FL, 33607
Address City State
Telephone Number of Designated Person: 813.574.5700
8. In addition to himself,the owner designates N/A of
to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statutes.
Telephone Number of Person or Entity Designated by Owner:
9. Expiration date of Notice of Commencement is one year from the date of recording unless a different date is specified:
WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT
ARECONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE
RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT.
STATE OF FLORIDA
COUNTY OF PINELLAS
(Sigrrgure of Owner or Owner's Authorized Officer/Director/Partner/Manager
Vice President
Signatory's Title/Office
The foregoing instrument was acknowledged before me this 3 day of March by
Steve Robert Smith as Vice President
(type of authority,e. �rustee,attorney in fact)for
Lennar Homes LLC (name of party on b alf ofwhomirstrument was executed).
Personally Known®OR Produced Identification❑ Notary Si
Type of Identification Produced Name(Print) Elissa olleran
Verification pursuant to Section 92.525,Florida Statutes. Under penalties of perjury,I declare that I have read the foregoing and that the facts stated in
it are true to the best of my knowledge and belief.
ELI35AM.HOLLERAN;. Signature of Natural Person Signing Above
Gmmlealon i1 FF 885637
o;=Ex'IraeJune6.2020
wpdata/bcs/bcs form: DondWnruTmy.FolnIuunnce100.3WTOte
STATE OF FLORIDA,COUNTY OF PASCO
THIS IS TO CERTIFY"HAT THE FOREGOING IS A
TRUE AND CORRECT COPY OF THE DOCUMENT
ON FILE OR OF PUBLIC RECORD IN THIS OFFICE
. # WITNESS MY hiAND*�&Cllj,FIAL SEAL TINS
i:n fSk��I0 7i'U8fJt
DAY OF 2 �9
pAt O'NEIL, MPTROLLER
DEPUTY CLERK
P'ASCO COUNTY, FLORIDA
- -- Permit No. 8616
Date Permitted
Builder Name/Owner Name G �— Control#
County Parcel No, j�"2 2%�'t�L� _ �bDiV:
Address/Location
1
Classification/Type of Use
i! TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: Za7'Z(1P
i'
Exempt ❑ Yes ❑ No How Determined
! Impact Fee Amount $. �3)(P c32 Zone No, TAZ:
{ SCHOOL IMPACT FEE
Account (056) Single-Family Detached House Amount $
(057) Mobile Home
(058) Other Residential
} 123) Collection Fee
,i
Exempt F�Yes ❑ No How Determined
PARKS AND RECREATION FEE
Land Account Land Credit Land Total
Recreation Account Recreation Credit Recreation Total
5 Zone TOTAL AMOUNT $
Exempt ❑Yes ❑ No How Determined
i
LIBRARY FEE
Land Account Land Credit Land Total
Facility Account Facility Credit Facility Total
I
Exempt ❑ Yes ❑ No How Determined Total Amounf_
RESOURCE FEE ERU
TOTAL AMOUNT
Prepared By _ Checked By
U.
NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION
PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE
BEEN PAID AND
RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY
Acknowledgement below does not Imply acceptance of concurrence,but simply receipt of a copy of this form,placing .
the building permit owner on notice of this assessment and the conditions of payment for same.
DATE RECEIVED BY
RECEIPT NO. DATE BY
• s
t
813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021
Building Department
Date Received Phone Contact for Permittingg [:8=13363 _ 2891
1 1 1 1 1 1 1 1 I l l i l
Owner's Name Lennar Homes,LLC Owner Phone Number 813.574.5700
Owner's Address 4600 W.Cypress St.Ste.200,Tampa,FL 33607 Owner Phone Number
Fee Simple Titleholder Name N/A Owner Phone Number
Fee Simple Titleholder Address N/A
JOB ADDRESS 3258 Moulden Hollow Drive LOT# . 0990
SUBDIVISION Hidden River Phase One A PARCEL ID# 24-26-21-0060-00000-0990
(OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED NEW CONSTR B—� ADD/ALT = SIGN = = DEMOLISH� INSTALL REPAIR
PROPOSED USE SFR = COMM 0 OTHER
TYPE OF CONSTRUCTION ryl BLOCK 0 FRAME = STEEL =
DESCRIPTION OF WORK Single Family Residence/Pool/Screen Enclosure/Fence
BUILDING SIZE U/R SF 2276 SQ FOOTAGE 1817 HEIGHT 1 Story
1Z BUILDING $ ' 7 u VALUATION OF TOTAL CONSTRUCTION
ELECTRICAL $. ® PROGRESS ENERGY Q W.R.E.C.
77 ♦♦ ff AMP SERVICE
PLUMBING $
MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION
=GAS 0 ROOFING .0 SPECIALTY = OTHER
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES �10
u
BUILDER 4 COMPANY I
Lennar Homes,LLC
SIGNATURE REGISTERED Y/ N FEE CURREK LZ
/N
Address 4600 W.Cypress St.Ste.2150,Tampa,FL 33607 License# FCG7C1518166
ELECTRICIAN COMPANY =Edmonson Electric, Inc.
SIGNATURE REGISTERED Y/ N FEE CURREN
Address 1034 Skipper Road, Tampa, FL 33613 License# EC13005408
PLUMBER COMPANY Bayonet Plumbing, Heating &AC, Inc
SIGNATURE REGISTERED Y/ N FEE CURREK Y/N
Address P.O. Box 5308, Bayonet, FL 34674-5308 License# I CFC042998
MECHANICAL COMPANY Bayonet Plumbing, Heating &AC, Inc
SIGNATURE REGISTERED Y/ N FEE CURREN Y/N
Address P.O. Box 5308, Bayonet, L 34674-5308 License# I CAC058062
OTHER COMPANY
SIGNATURE REGISTERED Y/ N FEE CURREN
Address 4211 Shoal Line Blvd, S ring Hill, FL 34607 License# CCC057991
11111111111111111111111111111111111111711111111111.11111111111111111
RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction,
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects
COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction.
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed;
Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance
SIGN PERMIT Attach(2)sets of Engineered Plans.
****PROPERTY SURVEY required for all NEW construction.
Directions:
Fill out application completely.
Owner&Contractor sign back of application,notarized
If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500)
** Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (copy of contract required)
Reroofs if shingles - Sewers Service Upgrades A/C Fences(Plot/Survey/Footage)
Driveways-Not over Counter if on public roadways..needs ROW
NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed" restrictions"
which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any
applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or
contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the
contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation
under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the
intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847-
8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign
portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the
contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco
County.
TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of
use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and
90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of
permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to
receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or
final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact
fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I
certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's
Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone
other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to
deliver it to the"owner" prior to commencement.
CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work
will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is
hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has
commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating
construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also
certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is
my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to:
- Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands, Water/Wastewater Treatment.
- Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering
Watercourses.
- Army Corps of Engineers-Seawalls, Docks, Navigable Waterways.
- Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment,-
Septic Tanks.
- US Environmental Protection Agency-Asbestos abatement.
- Federal Aviation Authority-Runways.
I.understand that the following restrictions apply to the use of fill:
- Use of fill is not allowed in Flood Zone W" unless expressly permitted.
- If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a
"compensating volume" will be submitted at time of permitting which is prepared by a professional engineer
licensed by the State of Florida.
- If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall
construction, I certify that fill will be used only to fill the area within the stem wall.
- If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots less than one (1)
acre which are elevated by fill, an engineered drainage plan is required.
If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in
this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work,
plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A
permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or
set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter
requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid
unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by
the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension
may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate
justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered abandoned.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
FLORIDA JURAT(F.S. 117.03)
OWNER OR AGENT 4 CONTRACTOR
Subscribed and sworn to(or affirmed)before this Subscribed and sworn to(or affirmed) fore me this
U0-rvov-r I by Paul Sweeney 03-Nov-17 by Paul Sweene
Who is/are personally known tome or VVho is/are personally known to me of has/have pr$dueed
as identification. as identification.
Notary Public Notary Public
Commission eS98537 Commission No. PP98537
Elissa M.Holleran Elissa M.Holleran
Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped
-�. _
�41I�rr 'aAi�,hl���e7�' `,�I'�IR.fn�di�nrl�f'�O�BGa
- rF.�p.�r��lP��19;�4�4
E�7�/��N'I�Pd1n'�L14h1A$!d✓`�k1b9yT4fII � � &�dd'fiN't�iKl94w�nAalk�Y'S,1iPll
Single. Family Dwelling
Pla
n Review.Comments
1: :F.F:E. shall be a.minimum of 8" above the road elevation.and an engineered site plan.
-2. _Lots shall be' aded.to.comply with R401.3 of the F.B:.C:
�' p.y
3. Compaction:test required.if 24" or more of f l dirt is brought in ai any one place: =
4: Tie in surveyrequired before pouring concrete.. . .
5. Driveways:require a R.O.W. use permit- All 4.sides of driveway that the sidewalk shall have
expansion matenal:.
6.. All setbacks.shall.be.met..' .
T- All pert markers shall be.uncovered and marked at time of first 'inspection:
. pro pert p y
8:. .All A.D.A.-requirements shall-be met.:'.
9. No:electric;plumbing, meclianical;.or framing shall be covered'without aninspection and
approval first. .
10. All Garages shall:comply with section R302:6.of the.F.B.C. (Fire Separation).
I1. Appliances:shall not be installed in.a location where subiect:to mechanical darriage unless. .
protected'by approved barriers. M303 4 ofthe F.B:C
12. Water heaters shall comply with section:P607.3 of the F.B.C.
13. Foundation supports for'A/C.units shall'be raised at least 3" above finished grade,. M1308.1
14. Return-air in all:bedrooms..F.B.C. M.I620.4
15. Smoke detectors are to be:installed in accordance:with.R3 III of theT.B.C.
16: All glazing requirements are:.to be in accordance with R308.4-'of the F.B.C.
17. All means.of egress are to be in:accordance with R311:of the F.B.C. :: -
18..`.`Green gypsum board shall not be used:as abacker.in7howers or tubs. R702.4:2.F.B.C.
19. Combination-type AFCI breakers'are.required:at all.locations requiring.an AFCI.type breaker:
-20. Carbon motioxide alarms:will be required in new construction that uses fossil-burning heating
or appliances or an attached garage: ;They shaall-be-installed in accordance with the F.B.C.
21. All plumbing,mechanical,:and electrical shall be separate from unit to:unit: This includes all
underground plumbing grid electric:
22. A112011:N.E.C. Codes will be enforced::.
23:Tamper-Resistant Receptacles in accordance with 406.11 of the 2011 N:E:C
: 24::Iri accordance with the Land.Development:Code; lots shall be sodded before final of least 10
feet around the structure.
25.'A.cony of the energy caels shall be with hermit at all tinter.
26 Conv of final insulation report shall be.nrovided with Permit before rinab
F:F:E.-Finished Floor Elevation
F.B:C-•Florida Building Code 6a'Edition
R.O.W.-Right of Way
A.D.A.-Americans with.Disabilities Act N.E.C.-National Electric.Code(2011) .
' SKETCH ONLY SEC. 24 TWP. 26 S, RNG. 21 E:
PLOT PLAN NOT A BOUNDARY SURVEY
LOT 99 BEARING BASIS:
HIDDEN RIVER PHASE ONE A NORTH BOUNDARY OF SUBJECT PLAT BEING S 89'40'43" E
PASCO COUNTY, FLORIDA. THIS SURVEY IS SUBJECT TO ANY FACTS THAT
NMAY BE DISCLOSED BY A FULL AND ACCURATE
PRELIMINARY DRAWING: ON LOT AREA CALCULATIONS TITLE SEARCH. ALSO SUBJECT TO SETBACKS,
THIS PLAN IS FOR PERMITTING PURPOSES LOT = 6600.00 SQ. FT, EASEMENTS AND RESTRICTIONS OF RECORD.
ONLY, NOT FOR CONSTRUCTION. VERIFY LIVING AREA = 1838 Q. FT. o
ALL DIMENSIONS BEFORE ANY CONSTRUCTION. ENTRY = 32 Q. FT, M UNDERGROUND FOOTER, STEM WALL, AND
GARAGE = 406 Q. FT. II UNDERGROUND UTILITIES ARE NOT LOCATED OR
LEGEND: COVERED LANAI =_ ZA-SQ. FT. = SHOWN.
f� PATIO = 23= PROPOSED DRAINAGE FLOW Q. FT. DO NOT SCALE THIS PRINT. DIMENSIONS AND
(00.00) = PROPOSED GRADE CONC. DRIVE = 339 SQ. FT. NOTES TAKE PREFERENCE.
E-00.00 = EXISTING GRADE A/C & CONC PAD = 18 Q. FT. c¢i
PRIVATE SIDEWALK = 72 Q. FT. DESCRIPTION NOT CONTAINING PLAT BOOK AND
IMPERVIOUS = 41 % PAGE INDICATES THAT PLAT IS IN
NOTES' = 2728 Q. FT. PRELIMINARY STAGE AND IS SUBJECT TO
LOT GRADING TYPE = A SOD = 3872 Q. FT. CHANGE AND/OR REVISION.
PROPOSED PAD ELEVATION N/A FRONT SETBACK = 20' OFF LOT AREA CALCULATIONS CERTAIN DATA SHOWN HEREON BASED ON SIDE SETBACK = 10' RIGHT of WAY = 20 7_00 gq, FT, ENGINEERING PLANS PROVIDED BY CLIENT.
DRIVE APRON = 144 Q. FT.
REAR SETBACK = 10' STRUCTURE TIES SHOWN HEREON DENOTES
PUBLIC SIDEWALK = 240 SQ. FT. MEASUREMENT FROM FORM BOARDS/FOUNDATION
SOD = 336 SQ. FT. TO PROPERTY LINE.
TOTALS * = 10' DRAINAGE/UTILITY EASEMENT
AREA = 7320.00 SQ. FT,
(P) DRIVEWAY = 483 S0. FT.
,,—PC SIDEWALK = 312 SQ. FT.
SOD = 4208 SQ. FT.
in
o
N
LOT 98
Lij
^ryl ry,
0
2 S 89'36'58" E 110.00'
. ... . ... .?. 'L.
r _o o.
.o o.
0 ..... ..... 0:
...I.... •^
20 50' ......................... O
J I O O I 59'-4' [j 0 30.17' O
03 * O
¢ O
2050'._._. ;
W. .... w w
0 oZ�m�= rn o
zv p-'`-', :e::. B Oa--a;< o o N LOT 329
LLI `�:; o_ w O
•N j + ' '. .F. N
J ZD
a'
0 z........I...36.17r--.......... o .........30:17.......... In
_o o.
o::o o:
. .. . .......:
2 . 0. �5. N 89'36'58" W 110.00'
ASJ ?19 J
LOT 100
7
V
PROPOSED:
LOWEST FLOOR ELEVATIONS:
T
LIVING AREA: 73.25'
GARAGE AREA: 72.71'
DESCRIPTION: ELEVATIONS REFERENCED TO
LOT 99, MAP OR PLAT ENTITLED "HIDDEN RIVER PHASE ONE A", NATIONAL GEODETIC VERTICAL
AS RECORDED IN PLAT BOOK 074, PAGES 101 THROUGH 121, DATUM OF 1929. MEAN SEA
OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. LEVEL= 00.00 FT.
z
E APPARENT FLOOD HAZARD ZONE: "X" COMMUNITY PANEL NO. 12101 C 0458 F EFFECTIVE DATE: 9/26/2014
LEGEND:
(C)= CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, q= CENTERLINE, A/C= AIR CONDITIONER, B/C= BACK OF CURB, C/S=
CONCRETE SLAB, CH= CHORD, CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= COVERED, E/P= EDGE OF PAVEMENT, ESM'T= EASEMENT,
i F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE, FIR= FOUND IRON ROD, FN&D= FOUND NAIL & DISK, FPP= FOUND PINCHED
PIPE, LFE= LOWEST FLOOR ELEVATION, MAS.= MASONRY, OR= OFFICIAL RECORD BOOK, PB= PLAT BOOK, PCP= PERMANENT CONTROL POINT, PRM= PERMANENT
REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & CAP No. 4493, SN&D= SET NAIL & DISK, TBM= TEMPORARY BENCHMARK,
U P= UTILITY POLE, W F= WOOD FENCE, R = RADIAL
` JOHN R.BEACH&ASSOCIATES,INC. Drawn By: SMS Square Feet: 6600.00 t LENNAR HOMES
i SURVEYORS AND MAPPERS Checked By:
i 911 WEST ST. PETERSBURG DRIVE
ONE OLDSMAR, FLORIDA 34677 JRB
WAY (813) 854-1276 FAX (813) 855-8370 Scale:
NOT VALID WITHOUT THE SIGNATURE AND Date: PLOT PLAN 10 9 17 ACS �� I✓? Zo/
i THE ORIGINAL RAISED SEAL OF A FLORIDA JOHN EACH NIDATE
I LICENSED SURVEYOR AND MAPPER FLOG6A R LAND SURVEYOR No. 2984 LB 4493
Revisions:
6 go�
NLPMj
-MID
�ah
6S
as
On
Le
tro
r-V7
ZI
sm
----------
..........
MCI"
CU zot
tle
7< 7E7,
7
3u
————- ————-
9z om
-ZE
-,.;7-T
MAJ
JL
L----------
Wt7-
VI
L6
'bu
1- 7
--!7--';k
v I
96
07
-----------
96
-M dA
L—---———————
PIC V4S&
j76 1 M dA
9z
4. N.
FORM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
0099
Project Name: 1791 B1 sf ADS Builder Name: Lennar Homes
Street: 3258 Moulden Hollow Drive Permit Office: Ci of ZephyrhiEs
City,State,Zip: FL, Permit Number: f s•
Owner: Lennar Homes Jurisdiction: 611 00
Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(1572.7 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1241.30 ft2
b.Frame-Wood,Adjacent R=11.0 331.33 ft2
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 4 d.N/A R= ft2
5. Is this a worst case? Yes 10.Ceiling Types (1817.0 sqft,) Insulation Area a.Under Attic(Vented) R=30.0 1817.00 ft2
6. Conditioned floor area above grade(ftZ) 1817 b.N/A R= ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ft2
11.Ducts R ft2
7. Windows(143.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 363.4
a. U-Factor: Dbl,U=0.54 87.00 ft2
SHGC: SHGC=0.31'
b. U-Factor: Dbl,U=0.56 33.33 ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.32 a.Central Unit 30.0 SEER:15.00
c. U-Factor: Dbl,U=0.56 23.00 ft2
SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a.Electric Heat Pump 26.0 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 1.233 ft.
Area Weighted Average SHGC: 0.308 14.Hot water systems
8. Floor Types (1817.0 sqft.) Insulation Area a.Electric Cap:40 gallons
a.Slab-On-Grade Edge Insulation R=0.0 1817.00 ft2 b. Conservation features EF:0.950
b.N/A R= ft2 None
c.N/A R= ft2 15.Credits Pstat
Glass/Floor Area: 0.079 Total Proposed Modified Loads: 58.13 PASS
Total Baseline Loads: 58.11
I hereby certify that the plans and specifications covered by Review of the plans and MILE S�, ?;
this calculation are in compliance with the Florida Energy specifications covered by this _ p
Code. calculation indicates compliance
with the Florida Energy Code. nrrr 'r!• • ="s;•�' �ti ;
PREPARED BY: Dam Autkh Before construction is completed `.•-
DATE: this building will be inspected for ( ;
compliance with Section 553.908
I herebycertify that this building,as designed,is in compliance Florida Statutes.
fY 9, 9 P
with the Florida Energy Code.
OWNER/AGENT: BUILDING F IAL
DATE: DATE:
- 67
Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.2.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
test report in accordance with R402.4.1.2.
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with Section 803 of RESNET Standards,is not greater than 0.030 Qn for whole house.
8/9/2017 7:16 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4
FORM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
0099
Project Name: 1791 B1 sf ADS ` Builder Name: Lennar Homes
Street: 3258 Moulden Hollow Drive Permit Office: City of Zephyrhills
City,State,Zip: FL, Permit Number:
Owner. Lennar Homes Jurisdiction: 611600
Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(1572.7 sgft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1241.30 ftz
b.Frame-Wood,Adjacent R=11.0 331.33 ftz
3. Number of units,if multiple family 1 c.N/A R= ftz
4. Number of Bedrooms 4 d.N/A R= ftz
5. Is this a worst case? Yes 10.Ceiling Types (1817.0 sgft.) Insulation Area 2
a.Under Attic(Vented) R=30.0 1817.00 ft
6. Conditioned floor area above grade(ftz) 1817 b.N/A R= ft2
Conditioned floor area below grade(ftz) 0 c.N/A R= ftz
11.Ducts R ftz
7. Windows(143.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 363.4
a. U-Factor: Dbl,U=0.54 87.00 ftz
SHGC: SHGC=0.31
b. U-Factor: Dbl,U=0.56 33.33 ftz 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.32 a.Central Unit 30.0 SEER:15.00
c. U-Factor: Dbl,U=0.56 23.00 ftz
SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ftZ a.Electric Heat Pump 26.0 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 1.233 ft.
Area Weighted Average SHGC: 0.308 14.Hot water systems
8. Floor Types (1817.0 sgft.) Insulation Area a.Electric Cap:40 gallons
a.Slab-On-Grade Edge Insulation R=0.0 1817.00 ftz b. Conservation features EF:0.950
b.N/A R= ftz None
c.N/A R= ftz 15.Credits Pstat
Glass/Floor Area: 0.079 Total Proposed Modified Loads: 58.13 PASS
Total Baseline Loads: 58.11
I hereby certify that the plans and specifications covered by Review of the plans and aZ?rIESTT
this calculation are in compliance with the Florida Energy specifications covered by this .Fp
Code. calculation indicates compliance .
�,/ with the Florida Energy Code.
PREPARED BY: Dam �{�H h Before construction is completed
DATE: this buildingwill be inspected for
P
compliance with Section 553.908
I herebycertify that this building,as designed, is in compliance Florida Statutes.
fY 9, 9 P
with the Florida Energy Code. 1 G'Op yy
OWNER/AGENT: BUILDING FFICIAL:
DATE: DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.2.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
test report in accordance with R402.4.1.2.
- Compliance with a,proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with Section 803 of RESNET Standards, is not greater than 0.030 Qn for whole house.
8/9/2017 7:16 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4
FORM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
0099
Project Name: 1791 B1 sf ADS Builder Name: Lennar Homes
Street: 3258 Moulden Hollow Drive Permit Office: City of Zephyrhills
City,State,Zip: FL, Permit Number:
'Owner. Lennar Homes Jurisdiction: 611600
Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(1572.7 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1241.30 ft2
b.Frame-Wood,Adjacent R=11.0 331.33 ft2
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 4 d.N/A R= ft2
5. Is this a worst case? Yes 10.Ceiling Types (1817.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1817.00 ft2
6. Conditioned floor area above grade(ft2) 1817 b.N/A R= ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ft2
11.Ducts R ft2
7. Windows(143.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 363.4
a. U-Factor: Dbl,U=0.54 87.00 ft2
SHGC: SHGC=0.31
b. U-Factor: Dbl,U=0:56 33.33 ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.32 a.Central Unit 30.0 SEER:15.00
c. U-Factor: Dbl,U=0.56 23.00 ft2
SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency,
d. U-Factor: N/A ft2 a.Electric Heat Pump 26.0 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 1.233 ft.
Area Weighted Average SHGC: 0.308 14.Hot water systems
8. Floor Types (1817.0 sqft.) Insulation Area a.Electric Cap:40 gallons
a.Slab-On-Grade Edge Insulation R=0.0 1817.00 ft2 b. Conservation features EF:0.950
b.N/A R= ft2 None
c.N/A R= ft2 15.Credits Pstat
Glass/Floor Area: 0.079 Total Proposed Modified Loads: 58.13 PASS
Total Baseline Loads: 58.11
hereby certify that the plans and specifications covered by Review of the plans and .
this calculation are in compliance with the Florida Energy specifications covered by this
Code. calculation indicates compliance
with the Florida Energy Code. ti
PREPARED BY: Dave >4w'/h Before construction is completed
DATE: this building will be inspected for �,�= - �C
compliance with Section 553.908
I herebycertify that this building,as designed,is in compliance Florida Statutes.
fY 9� 9 p
with the Florida Energy Code. G'OD y`tg.1
OWNER/AGENT: BUILDING OFFI IAI
DATE: DATE:
10,
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.2.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
test report in accordance with R402.4.1.2.
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with Section 803 of RESNET Standards, is not greater than 0.030 Qn for whole house.
8/9/2017 7:16 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Pagel of 4
FORM R405-2014
PROJECT
Title: 1791 B1 sf ADS Bedrooms: 4 Address Type: Street Address
Building Type: User Conditioned Area: 1817 Lot#
Owner: Lennar Homes Total Stories: 1 Block/SubDivision:
#of Units: 1 Worst Case: Yes PlatBook:
Builder Name: Lennar Homes Rotate Angle: 45 Street:
Permit Office: Cross Ventilation: County: Pasco
Jurisdiction: Whole House Fan: City,State,Zip:
Family Type: Single-family FL,
New/Existing: New(From Plans)
Comment:
CLIMATE
/ IECC Design Temp Int Design Temp Heating Design Daily Temp
v Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,Tampa FL TAMPA_INTERNATI 2 39 91 70 75 645.5 54 Medium
BLOCKS
Number Name Area Volume
1 Block1 1817 14536
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
1 Main 1817 14536 Yes 5 4 1 Yes Yes Yes
FLOORS
# Floor Type Space Perimeter R-Value Area Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio Main 155 ft 0 1817 ft2 _e 0.3 0 0.7
ROOF
/ Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
1 Hip Composition shingles 1968 ft2 0 ft2 Medium 0.85 No 0.9 No 0 22.6
ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Vented 300 1817 ft2 N N
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Vented) Main 30 Blown 1817 ft2 0.11 Wood
8/9/2017 7:16 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 4
FORM R405-2014
WALLS
Adjacent Space Cavity Width Height Sheathing Framing Solar Below
1 N=>NE Exterior Concrete Block-Int Insul Main 4.0999 19 6 8 156.0 ft2 0 0.600000 0
2 N=>NE Garage Frame-Wood Main 11 20 8 8 165.3 ft2 0 0.01 0
3 W=>NW Garage Frame-Wood Main 11 20 9 8 166.0 ft2 0 0.01 0
4 E=>SE Exterior Concrete Block-Int Insul Main 4.0999 58 8 464.0 ft2 0 0.600000 0
5 S=>SW Exterior Concrete Block-Int Insul Main 4.0999 34 8 272.0 ft2 0 0.600000 0
6 W=>NW Exterior Concrete Block-Int Insul Main 4.0999 37 8 8 301.3 ft2 0 0.600000 0
7 S=>SW Exterior Concrete Block-Int Insul Main 4.0999 6 8 48.0 ft2 0 0.600000 0
DOORS
# Ornt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 N=>NE Insulated Main None .2 3 6 8 20 ft2
2 N=>NE Wood Main None .4 2 8 6 8 17.8 ft2
WINDOWS
Orientation shown is the entered orientation =>)changed to Worst Case.
/ Wall Overhang
V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening
1 N=>NE 1 Metal Low-E Double Yes 0.56 0.28 23.0 ft2 1 ft 0 in 4 ft 2 in Drapes/blinds None
2 E=>SE 4 Metal Low-E Double Yes 0.54 0.31 32.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds None
3 S=>SW 5 Metal Low-E Double Yes 0.54 0.31 32.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds None
4 S=>SW 7 Metal Low-E Double Yes 0.56 0.32 33.3 ft2 2 ft 0 in 0 ft 4 in Drapes/blinds None
5 W=>NW 6 Metal Low-E Double Yes 0.54 0.31 23.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds None
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 427 ft2 427 ft2 42 ft 8 ft 1
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000356 1695.9 93.1 175.09 .2669 7
HEATING SYSTEM
# System Type Subtype Efficiency Capacity Block Ducts
1 Electric Heat Pump None HSPF:8.5 26 kBtu/hr 1 sys#1
8/9/2017 7:16 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 4
FORM R405-2014
COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit Split SEER: 15 30 kBtu/hr 900 cfm 0.85 1 sys#1
HOT WATER SYSTEM:
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.95 40 gal 70 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None ftz
DUCTS
—Supply— —Return— Air CFM 25 CFM25 HVAC#
V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 363.4 ft Main 90.85 ft Proposed Qn Main —cfm 54.5 cfm 0.03 0.60 1 1
TEMPERATURES
Programable Thermostat:Y Ceiling Fans:
CoolingJan Feb Mar [ ]Apr May rl
Jun Jul rl
Augri
Se [ ]Oct Nov [ ]Dec
Heatin HJan N Feb Mar [ ]Apr L May Jun Jul AuSep [ ]Oct XNov [X]Dec
Ventin Jan Feb X Mar [X]A r [ Ma Jun Jul Aug Se [X]Oct X Nov [ ]Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM- 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
8/9/2017 7:16 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 4
FORM R405-2014
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 100
The lower the EnergyPerformance Index, the more efficient the home.
„ FL,
1. New construction or existing New(From Plans) 9. Wall Types Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1241.30 ft2
b.Frame-Wood,Adjacent R=11.0 331.33 ft2
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 4 d.N/A R= ft2
10.Ceiling Types Insulation Area
5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1817.00 ft2
6. Conditioned floor area(ft2) 1817 b.N/A R= ft2
7. Windows- Description Area c. A R= ft2
a. U-Factor: Dbl,U=0.54 87.00 ft2 11.Ducts R ft2
SHGC: SHGC=0.31 a.Sup:Attic,Ret:Main,AH:Main 6 363.4
b. U-Factor: Dbl,U=0.56 33.33 ft2
SHGC: SHGC=0.32 12.Cooling systems kBtu/hr Efficiency
c. U-Factor: Dbl,U=0.56 23.00 ft2 a.Central Unit 30.0 SEER:15.00
SHGC: SHGC=0.28
d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency
SHGC: a.Electric Heat Pump 26.0 HSPF:8.50
Area Weighted Average Overhang Depth: 1.233 ft.
Area Weighted Average SHGC: 0.308
8. Floor Types Insulation Area 14.Hot water systems
a.Electric Cap:40 gallons
a.Slab-On-Grade Edge Insulation R=0.0 1817.00 ft2 EF:0.95
b.N/A R= ft2
c.N/A R= ft2 b. Conservation features
None
15.Credits Pstat
certify that this home has complied with the Florida Energy Efficiency Code for_Building lk Eri'S
Construction through the above energy saving features which will be installed (or exceeded) ' Ao
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: Date: 11/08/17
Address of New Home: 3258 Moul n Hollow Drive City/FL Zip: Zephyrhills,FL 33540 'C
oD
*Note: This is not a Building Energy Rating. If your Index is below 70,your home may qualify for energy efficient
mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
8/9/2017 7:17 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1
r "
Building Analysis Job: 1791B sf ADS
g Y Date: 10131/2017
Entire House By: Dave
Bayonet Plumbing Heating and Air
Project I • •
For: Lennar Homes
Design Conditions
Location: Indoor: Heating Cooling
Tampa International AP, FL, US Indoor temperature(OF) 70 75
Elevation: 10 ft Design TD (OF) 39 16
Latitude: 28°N Relative humidity (%) 50 50
Outdoor: Heating Cooling Moisture difference(gr/lb) 34.7 54.7
Dry bulb(OF) 31 91 Infiltration:
Daily range(OF) - 14 ( L ) Method Simplified
Wet bulb(°F) - 77 Construction quality Semi-tight
Wind speed(mph) 15.0 7.5 Fireplaces 0
Component Btuh/ftz Btuh % of load
Walls 5.6 6529 25.4 Ducts
Glazing 30.2 4772 18.6 wail
Doors 23.5 466 1.8 nfilo-ation
Ceilings 1.3 2271 8.8
Floors 3.4 6125 23.9
Infiltration 2.2 2887 11.2
Ducts 2616 10.2
Piping 0 0 Glazing Floors
Humidification 0 0
Ventilation 0 0 other Ceilings
,Adjustments 0
Total 25667 100.0
Component Btuh/ftz Btuh % of load
Walls 2.8 3248 14.4 Walls
Glazing 48.5 7661 33.9 Internal Gains
Doors 18.4 365 1.6
Ceilings 1.7 3140 13.9
Floors 0 0 0 j
.-Infiltration 0.5 647 2.9 :
Ducts 2982 13.2 Ducts
Ventilation 0 0
Internal gains 4555 20.2 Glazing
Blower 0 0 Infiltration
Adjustments O Ceilings
Total 22597 100.0 Other
Latent Cooling Load= 3575 Btuh
Overall U-value= 0.104 Btuh/ftz-°F
Data entries checked.
htsoft® 2017-Oct-3107:24:08
WI"1
.�- 9 Right-Suite®Universal 2017 17.0.23 RSU05714 Page 1
A"CK ...CBA27UHE AH's117918 sf ADS template 2.5ton.rup Calc=MJ8 Front Door faces: W
Project SummaryJob: 1791B sf ADS
1Date: 10131/2017
Entire House By: Dave
Bayonet Plumbing Heating and Air
Proiect Information
For: Lennar Homes
Notes: 40'ADS-2017
Design Information
Weather: Tampa International AP, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 31 OF Outside db 91 OF
Inside db 70 OF Inside db 75 OF
Design TD 39 OF Design TD 16 OF
Daily range L
Relative humidity 50 %
Moisture difference 55 gr/lb
Heating Summary - Sensible Cooling Equipment Load Sizing
Structure 23051 Btuh Structure 19615 Btuh
Ducts 2616 Btuh Ducts 2982 Btuh
Central vent(0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh
none (none)
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 25667 Btuh Use manufacturer's data y
Rate/swing multiplier 1.00
Infiltration Equipment sensible load 22597 Btuh
Method - Simplified Latent Cooling Equipment Load Sizing
Construction quality Semi-tight
Fireplaces 0 Structure 3041 Btuh
Ducts 534 Btuh
Central vent(0 cfm) 0 Btuh
Heatingg Coolingg (none)
Area(ftz) 1817 1817 Equipment latent load 3575 Btuh
Volume(ft') 15459 15459
Air changes/hour 0.26 0.14 Equipment Total Load (Sen+Lat) 26172 Btuh
Equiv.AVF (cfm) 67 36 Req. total capacity at 0.85 SHR 2.2 ton
Heating Equipment Summary Cooling Equipment Summary
Make Lennox Make Lennox.
Trade 14HPX SERIES Trade 14HPX SERIES
Model 14HPX-030-230-21 Cond 14HPX-030-230-21
AHRI ref 10258600 Coil CBA27UHE-030-230*++TDR
AHRI ref 10258600
Efficiency 8.5 HSPF Efficiency 13.0 EER, 15 SEER
Heating input Sensible cooling 25500 Btuh
Heating output 26400 Btuh @ 47'F Latent cooling 4500 Btuh
Temperature rise 24 OF Total cooling 30000 Btuh
Actual air flow 1000 cfm Actual air flow 1000 cfm
Air flow factor 0.039 cfm/Btuh Air flow factor 0.044 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.86
Capacity balance point= 31 OF
Backup: n/a n/a
Input= 0 kW, Output=0 Btuh, 100 AFUE
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
L + wrilghtsoftm 2017-Oct-31 07:24:08
..r\ Right-Suite®Universal 2017 17.0.23 RSU05714 Page 1
'�� ...CBA27UHE AH's\1791B sf ADS template 2.5ton.rup Calc=MJ8 Front Door faces: W
Manual S Compliance Report Job: 1791E sf ADS
p p Date: 1013112017
Entire House By: Dave
Bayonet Plumbing Heating and Air
Project Information
For: Lennar Homes
1
Cooling Equipment
Design Conditions
Outdoor design DB: 91.3°F Sensible gain: 22597 Btuh Entering coil DB: 75.7°F
Outdoor design WB: 77.3°F Latent gain: 3575 Btuh Entering coil WB: 62.8°F
Indoor design DB: 75.0°F Total gain: 26172 Btuh
Indoor RH: 50% Estimated airflow: 1000 cfm
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: SpIitASHP
Manufacturer: Lennox Model: 14HPX-030-230-21+CBA27UHE-030-230*++TDR
Actual airflow: 1000 cfm
Sensible capacity: 25500 Btuh 113% of load
Latent capacity: 4500 Btuh 126% of load
Total capacity: 30000 Btuh 115% of load SHR: 85%
Heating Equipment
Design Conditions
Outdoor design DB: 30.8°F Heat loss: 25667 Btuh Entering coil DB: 69.6°F
Indoor design DB: 70.0°F
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: SpIitASHP
Manufacturer: Lennox Model: 14HPX-030-230-21+CBA27UHE-030-230*++TDR
Actual airflow: 1000 cfm
Output capacity: 26000 Btuh ' 101% of load Capacity balance: 31 °F
Supplemental heat required: 0 Btuh Economic balance: -99 °F
Backup equipment type: Elec strip
Manufacturer: n/a Model: n/a+n/a
Actual airflow: 1000 cfm
Output capacity: 0 kW 0% of load Temp. rise: 0 °F
Meets are all requirements ofACCA Manual S.
� 2017-Oct-31 07:24:08
�. . I}J}} wrihtsoft'9 Right-Suite®Universal 2017 17.0.23 RSU05714 Page 1
)4CCk ...CBA27UHE AH's11791B sf ADS template 2.5ton.rup Calc=MJ8 Front Door faces: W
Lennar Homes-3258 Moulden Hollow Dr:2,276 sq ft
Column ts
SQ. FEET PRICE
MAIN OR LIVING: 2,276 $ 112.65
OTHER AREA UNDER ROOF: - $ 88.00
OTHER: - $ -
VALUATION $ 256,391.40
FEE SHEET $ 959.00
ADDRESS $ 40.00
DRIVEWAY $ 40.00
BUILDING: $ 1,058.18
ELECTRICAL: $ 215.78
PLUMBING: $ 143.85
MECHANICAL: $ 100.70
SUB-TOTAL $ 1,518.50
TOTAL $ 1,518.50
SEWER: n/a
WATER: n/a
IRRIGATION: $ -
TOTAL: $ -
WATER METER: n/a
IRRIGATION METER $ -
i
FIRE DEPARTMENT FEES
PLANS TOTAL: n/a
INSPECTION TOTAL:
PERMIT TOTAL
TOTAL: $ -
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
FIRE $ 273.00
5% $ 26.35
TOTAL: $ 553.35
SUB-TOTAL $ 2,071.85
PARK IMPACT FEES $ 769.56
SIF'S: $ 4,828.00
100.0% $ 4,828.00
1.0% $ 48.28
TOTAL: $ 4,876.28
T I F'S: $ 3,632.00
99% $ 3,595.68
1% $ 36.32
TOTAL: $ 11,349.69
5335 - 8TH STREET
(813)780-0020
CERTIFICATE OF OCCUPANCY
Address: 3258 MOULDEN HOLLOW DR Owner: LENNAR HOMES LLC
ZEPHYRHILLS, FL. 4600 W. CYPRESS ST STE 200
Subdiv: HIDDEN RIVER TAMPA FL 33607
Parcel: 24-26-21-0060-0000-0990 Work Type: 101-NEW CONST/SFR
Construction Type: NOT APPLICABLE ❑ Sprinklers
Use Classification: NOT APPLICABLE
Permit Number: 19518
Date• 7/18/2018
a% '
ISSUE Y: BUILDI OFFICIAL :
WATER MUST BE CHANGED OVER WITHIN 10 DAYS OF ISSUANCE
GARBAGE DEPOSIT MUST BE APPLIED FOR PRIOR TO ISSUANCE