Loading...
HomeMy WebLinkAbout18-19541 CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 19541 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL PERMIT INFORMATION LOCATION INFORMATION Permit#:19541 Issued: 4/11/2018 Address: 5023 SUMMERHILL DR Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 265,854.00 Total Fees: 17,857.97 Subdivision: SUMMERHILL Amount Paid: 17,857.97 Date Paid: 4/11/2018 Parcel Number: 12-26-21-0100-00000-0120 CONTRACTOR INFORMATION OWNER INFORMATION ' Name: BAILEY CONTRACTING LLC Name: BUTTERFIELD INVESTMENTS INC Addr: 4209 GALL BLVD Address: 31325 AMBERLEA RD ZEPHYRHILLS, FL. 33542 DADE CITY FL 33523-6225 Phone: (813)377-7395 Lic: Phone: 813-973-5250 Work Desc: CONSTRUCT SINGLE FAMILY 2,360 SQ FT APPLICATION FEES BUILDING FEE 1,472.40 ELECTRICAL FEE 308.25 PLUMBING FEE 205.50 MECHANICAL FEE 143.85 SEWER CONNECTION RESIDEW 2,090.00 WATER CONNECTION RESIDENT 1,010.00 WATER METER RES 3/4" 473.78 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE NEW 7,128.00 SCHOOL-SFR NEW 2% 71.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32 OtNoy, Inspections Required FOOTER 2ND ROUGH PLUMB MISC INSULATION CEI ING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO CCUPANCY BEFORE C.O. CONTRACT R IGNATURE PERMIT OFFIJEA PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER Jacqueline Boges From: TQ Randolph (City of Zephyrhills Support)<support@zephyrhillsfl.zendesk.com> Sent: Wednesday, April 25, 2018 6:41 PM To: Jacqueline Boges Subject: [FATHOM] Re: 5023 Su.mmerhill-dr"bp#19541 ##- Please type your reply above this line -## Your request (#207857) has been solved. TO REOPEN THIS REQUEST, reply to this email or click the link below: https://zephyrhilisfl.zendesk.com/hc/requests/207857 .................................................................................................................................................................................................................................................................................................................................................................................... TQ Randolph (City of Zephyrhills Support ) -- Apr 25, 3:40 PM MST C o m plete9`90441==2-9'$8-1..5-9;WS.Of#.668a90 Best Regards, TQ1 FATHOM Support .................................................................................................................................................................................................................................................................................................................................................................................. TQ Randolph (City of Zephyrhills Support ) i Apr 12, 2:03 PM MST Account has been created, pending mapping. 990441-2988159 Best Regards, TQ1 FATHOM Support ........................................................................................................................................................................................................................................................................................................................................................:...... ................. ... Jacqueline Boges f -- Apr 12, 5:24 AM MST full service 5023 summerhill dr by#19541 water sewer and water meter This email is a service from City of Zephyrhills Support . 1 CITY OF f j j / BUILDING ZEPHYRHILLS NOTIiCE DEPARTMENT OF ADDITION CAR CORRECTION D • NOT REMOVE ADDRESS DATE PERMIT¢, 2 v - - y I THIS JOB HAS NOT BEEN COMPLETED. The following additions or corrections shall be made before the jab will be accepted. r e ^ r it is unlawful for any Carpenter,Contractor,Builder,or other persons,to AFTER CORRECTIONS ARE MADE CALL cover or cause to be covered,any part of the work with flooring,lath,earth 780-002 FOR RE INS ECTION or other material,until the proper Inspector has had ample time to approve the Installation. OFFICE HOURS 7:30AM-4:30 PM MON.-FRI. INSPECTOR v ' II�O flluu City of Zephyrhills �- �: 'BUILDING PLAN REVIEW COMMENTS f Contractor/Homeowner: Date Received: 3-2-o—1 - Site: 6-DZ3 Permit Type: aGi L54-u-U c c Approved w/no comments:❑ Approved w/the below comments: �/ Denied w/the below comments: ❑ This comment sheets 1 be kept with the permit and/or plans. Kalvin Swit -Plans Examiner Date ontractor and/or Homeowner (Required when comments are present) 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Y , Date Received Phone Contact for Permitting 1 973 0-,52-50 Owner's Name (,rF-fccc✓ {(Ol /h 1/-c j*r e 7- 1•IC Owner Phone Number p J� 73 6-2, �o Owner's Address /32 Ambe,--Iza- /`d 06dtO Owner Phone Number Fee Simple Titleholder Name Owner.Phone Number Fee Simple Titleholder Address JOB ADDRESS 5023Su,-)r-e, /-14/ �YIv��//L 7 LOT# SUBDIVISION �J(AL W114- -�j PARCEL ID# 1G 2/ -L1-O —00000-020 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR e ADD/ALT SIGN Q Q DEMOLISH 9 INSTALL REPAIR PROPOSED USE � SFR = COMM = OTHER TYPE OF CONSTRUCTION � r BLOCK = FRAME = STEEL y= DESCRIPTION OF WORK1 lve-w (UY1 S P/u �-� o' S I/� �'� F-Lt M i 1[1/ j�(IJUIr/t BUILDING SIZE q /v X 60 SO FOOTAGE � 60d HEIGHT ✓ BUILDING VALUATION OF TOTAL CONSTRUCTION =ELECTRICAL $ 0 AMP SERVICE 2,G() PROGRESS ENERGY Q W.R.E.C. =PLUMBING 1$ =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION =GAS = ROOFING 0 SPECIALTY = OTHER lL FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES /NO. BUILDER �� COMPANY 13af AG ca,"if%G G rG SIGNATURE 'J(/ /1 > REGISTERED Y/ N'' FEE CURREN Y/N / Address �- 7��"( G d f1 g1(rLl License# I G� ELECTRICIAN COMPANY �l SIGNATURE v REGISTERED Y/ N FEE CURREN Y/N i Address ^ License# J --(90( U PLUMBER 1 COMPANY IAIc SIGNATURE 1 J REGISTERED Y/ N FEE CURREN Y/N Address Slog I 7t1 st 2 k. Of r-L 3 3 s-q ZI License# 1CP C IL)25&0 MECHANICAL COMPANY �3}y/�.J �/�l !�✓+ (l fIS G/t SIGNATURE REGISTERED Y/ N FE CURREN Y/N'L Address L 1 A it//�7 ���i��S License# 1 4!o' G OTHER COMPANY SIGNATURE REGISTERED I Y/ N FEE CURREN Y/N Address License# IIIIIIIIIIIIIIIIIIttlltllltttltltttttltlllttlllltltttttlttltlttllll RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ""PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500) Agent(for the contractor)or Power of Attomey(far the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW ' NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work,they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the"contractor Block"of this application for which they will be responsible. If you, as the owner sign as the contractor,that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use in existing buildings, or expansion of existing buildings,as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands,that such fees, as may be due,will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a"certificate of occupancy"or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended): If valuation of work is$2,500.00 or more,I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner",I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner"prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction,zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work,and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls,Docks,Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone"W unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume"will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction,I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties,the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill,an engineered drainage plan is required. If I am the AGENT FOR THE OWNER,I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate,cancel,alter,or set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans,construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance,or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced. An extension may be requested, in writing,from the Building Official for a period not to exceed ninety(90)days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. FLORIDA JURAT(F.S.117.03) WX OWNERORAGENT CONTRACTOR W Subscribed and sworn to(or affirmed)before me thl ubscribed and sworn to(or affirmed)before rfie this by by Who is/are personally known to me or has/have produced Who is/are personally known to me or has/have produced as identification. as identification. Notary Public Notary Public Commission No. Commission No. Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped PASCO COUNTY, FLORIDA Permit No. t Date Permitte Builder Name/Owner Name ' e �xJl �Firi l Control# ' County Parcel No. 2.2(u -?.1-�?I t0-L?DODO-�bZ SubDiv: 1( Address/Location Ji' 2 cJ t1 Classiflcationffype of Use. awl c? TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: Exempt [] Yes ❑ No How Determined Impact Fee Amount A 3,632.�Q Zone No. TAZ: SCHOOL IMPACT FEE Account (056) Single-Family Detached House Amount $ _ 77 j2 63. 00- (057) Mobile Home (058) Other Residential 123) Collection Fee Exempt ( Yes ❑No How Determined PARKS AND RECREATION FEE Land Account Land Credit Land Total Recreation Account Recreation Credit -Recreation Total Zone TOTAL AMOUNT $ 7 Exempt ❑Yes ❑ No How Determined LIBRARY FEE Land Account Land Credit Land Total - Facility Account Facility Credit Facility Total Exempt ❑ Yes ❑ No How Determined Total Amoun RESOURCE FEE ERU TOTAL AMOUNT Prepared By Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINsl PERFORRAr r�. ... - •-~- 5023 Summerhill Dr 2,360 Sq Ft Column El SQ. FEET PRICE MAIN OR LIVING: 2,360 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 265,854.00 FEE SHEET $ 1,370.00 ADDRESS $ 40.00 DRIVEWAY $ 40.00 BUILDING: $ 1,477.40 ELECTRICAL: $ 308.25 PLUMBING: $ 205.50 MECHANICAL: $ 143.85 SUB-TOTAL $ 2,135.00 TOTAL $ 2,135.00 SEWER: $ 2,090.00 n/a WATER: $ 1,010.00 n/a IRRIGATION: $ - TOTAL: $ 3,100.00 WATER METER: $ 473.78 n/a IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 6,262.13 PARK IMPACT FEES $ 769.56 SIF'S: $ 7,1 0 100.0% $ 7,128. 1.0% $ 71 28 TOTAL: $ 7,19 .'28 T I F'S: $ 3,632.00 99% $ 3,505. 1% $ 8,.32 TOTAL: $ 17,8'62.97 Sin le F' l DWelhng Y : Plan Reievcj Coinnients: 1: F.F.E. shall be-a minimuin:of.8".above.the road elevation'and an engineered.site plan. 2.. Lots shall be'graded to comply with R401.3 of theF.B;C: 3.: .Coinpaetion test required if 24" or more of fill dirt is brought.iwdi any one place: 4.. :Tie in' survey.required:before pouring concrete," 5. Driveways:require a R:O.W. use permit:. A114 sides of driveway.thrti the sidewalk shall have. :expansion material:. 6.. All setbacks shall:be met. 7. All property_markers shall be.uncovered and marked at time of first 'inspection: 8:. :All A.D.A:requirements shall be rnet. 9.: No:electric;plumbing,mechanical,,or:.. airing shall-be covered without an inspection.and approval first,... 10. All: Garages shall,comply.with:section R302:6.of the.F.B.C.:(Fire-Separation).. 11. Appliances shall not be installed in-a locationwhere subjectto.niechariical damage unless protected by approved,barriers: M303.4'of the F.B:C. = 12. Water heaters shall comply with section.P607,3 of the F.R.C. 13.Foundation supports for A/C units.shaff be raised at least 3 above finished grade. M1308,1 14..Return air in all bedrooms..F.B.C: M1620.4 15: Smoke detectors'are to be histalled:in accordance with R313:.1 of-the E.B.C. 16: All glazing requirements are.to be in.accordance with R308,4.of the F.B.C. 17.'All means of egress are to:be in accordance with R3 I f of the F;B.G., .: gyp 18. Green surri board shall riot be used:as a backer.ih showers or tubs. R702.4'2T.B.C. 19. Combination-type AFCI breakers are,required at all locations requiring=an AFCI type breaker: 20. Carbon monoxide alarms will be required in riew:construction that uses fossil-burning heating or appliances or an attached garage:. They shall be installed in accordance'with the F.B.C. 21. A11 plumbing,mechanical,and electrical shall be separate from unit to:unit: This includes all, underground plumbing and electric: 22. All 2011'N;E:C: Codes.will.be enforced; 23.Tampet- Resistant Receptacles in accordance with 406.11 of the 2011 N:E:C 24: h accordance--With the Land.Development:Code,'lots.shall be,sodded'before final at least-10 feet`around the structure: 25 A.copy of the eiiery cacls shall be with pertttitat all titres 26. Copy of final insulation report shall be.nrovided with.hermit before.fiitaL F.F:E.-Finished Floor Elevation, - F.B.C- Flohda.Building Code 6t'Edition R.O.W.-Right of Way. A.D.A.-Americans with.Disabilities Act . N.E.C.-National Electric:Code(2011). Legend P.O.C. Point of Commencement ® Indicates Asphalt Pavement P.C.P. Permanent Control Point P.R.M. Permanent Reference Monument T.O.B. Top of Bank P.O.B. Point of Beginning T.O.S. Toe of Slope P.O.L. Point on Line Conc. Concrete F.I.R. Found Iron Rod Asph. Asphalt F.I.P. Found Iron Pipe Mas. Masonry F.N.& D. Found Nail & Disc Fr: Frame W %P.S.M, t+ F.C.M. Found Concrete Monument W.F. Wire Fence 6061 L (R) Per legal Description or Plat(Recorded) Wd.F. Wood Fence C Calculated CLF Chain-Link Fence M Field Measured S.P. Screen Porch B/D Proportioned Section Breakdown CP Carport RAD. Radius OHL Overhead Utility Line Ch.L. Chord Length U/P Utility Pole Ch.B. Chord Bearing E/P Edge of Pavement S S.I.R. Set 1/2" Iron Rod Capped with U/C Utility Cylender Identification "PSM 6061" R/W Right of Way SCALE: 1" = 30' S.N.& D. Set Nail & Disc (L Centerline Stamped "PSM 6061" A/C Air Conditioner 0' 30, 60' CURVE TABLE CURVE CENTRAL ARC CHORD CHORD NO. RADIUS ANGLE LENGTH BEARING DISTANCE C1 170.00' 10'48'36 32.01' S. 13°46'53" E. 31.96' (R) S. 13°51'18" E. 32.15' (M) �C2 145.00' 1°41'06" 4.27' S. 18*20'11" E. 4.27' (R) S. 19*29'19" E. 4.31' (M) C3 175.00' 19'06'04" 58.34' 'S. 09'37'42" E. 58.07' (R) S. 09°37'46" E. 58.08' (M) I LOT 13 F.I.R. 5/8" with F.I.R. 5/8" with ID Cap 186382" I I C Cap "LB6382" Non—Radial Line Electric I CLF 0.1' W jj N. 89°47'20" E. — 134.46' (M) Transformer I • N. 89°52'55" E. — 134.52' (R) ;/ , , , F.N.& D. P.C.P. � r / "RLS4281PCP" t ,/ S.I.R. f \ i DO r O O of 00 LOT 12VACANT CP rn Ln O OA. ✓ � �r'C ', O O J iF�/ D. P.C.P. 81 PCP" �- N S. 89°52'85" W. — 59.2 ' (R &(M) \ j Non—Radial Line F.C.M. 4"x 4" with F.I.R. 5/8" with 1 j 1 CLF Corner 0.2' N, ID Disc "RLS4281° ID Cap "LB6382-, CLF Coernwe 0.2' S&W 49.F. E Corner F.C.M. CLF 0.1' W I �A Wd.F. Corner 0.3' S, I' 50.3' E of F.C.M. I O , Wd.F. Corner 0.2' S of and 34.4' W of F.I.R. Centerline Intersection I OLD MILL LANE y LOT 11 11 O I F.N.& D. P.C.P. "RLS428IPCP" 31009 Pasco Road Phone: (352) 5M-3660 John Walsh, Professional SUrve or k �f�a . _ er San Antonio, Florida 33576 Email: psm6061Cgmail.com Professional License number LS 6061 -BOUNDARY SURVEY Not valid without the signature and the original raised seal Client: Butterfield Investments, Inc. of a Florida licensed surveyor and mapper. Work order number: W18-0209 P' Date of Survey: 2/22/2018 Additions or deletions to this survey map or report by other than the Certified To: Butterfield Investments, Inc;';. signing party prohibited without written consent of the signing party. ff UP PRO ff 15 V Offl COY R0550R XIM NMI John Walsh, P.S.M. PAGE SECTION 12 SF_ PAGE 2 FOP, %5 NA TUPF_ & SEAL OF, 2 TOWNSHIP 26 S RANGE 21 E PASCO COUNTY, FLORIDAI Florida Surveyor's Registration No. 6061 llllllllillillilllllllllllllllllllllllllllllllllllllllllllll w;n DS: 0100007� IT: 0.00 00 2018043784 /-03/15/20)18 B. M. , Dpty Clerk Permit No. Parcel ID No L_r NOTICE OF COMMENCEMENT c State of r /0 County of PCs`� C 0 THE UNDERSIGNED hereby gives notice that Improvement will be made to certain real property,and in accordance with Chapter713,Florida Statutes, W the following information Is provided in this Notice of Commencement O r- 1. Description of Property: Parcel Identification No./a '2 "Z '��Q d d QQ 2 0 1 fA rn (�Z He'll Q✓i�e. ZGOf)o✓h.11f FL 3 3SNZ ny Street Address: 5 - 3 `�St�wun Cr r ; ®z 2. General Description of Improvement new CCnv/aL—It'dri sin R�e �A/t►/�h �6H'7� r+m (00 3. Owner Information gr Lessee information If the Lessee contracted for the improvement: 0 M0 �u-f -ee-h-- /d InVc)7'"e"/i , A c • - N 3 � 31325 /f"��s•/ca r2 d DI do G'ty Address City State O F►r- Interest In Property:O 11/4[! X Name of Fee Simple Titleholder. 00 (If different from Owner listed above) r3 Address —{-�/ �C(r/{ City State z 4. Contractor. 'Tt)t f �IZO9Nam� d ze0/1(�r��'//� �� m Address b��^ 72?- 1-1z3 2 city State Contractor's Telephone No.: b 2f 5. Surety: Name Address City State Amount of Bond: $ Telephone No.: 6. Lender. Name Address City State Lender's Telephone No.: 7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)(7),Florida Statutes: Name Address City State Telephone Number of Designated Person: 8. In addition to himself,the owner designates of_ to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statutes. Telephone Number of Person or Entity Designated by Owner. g. Expiration date of Notice of Commencement(the expiration date may not be before the completion of construction and final payment to the contractor,but will be one year from the date of recording unless a different date is specified): WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13. FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalty of perjury,I declare that I have read the foregoing notice of commencement and that the facts stated therein are We to the best of my knowledge and belief. STATE OF FLORIDA �T 7✓ COUNTY OF PASCO Signature of Owner or Lessee,or Owner's 'r Lessee's Authorized Officer/Director/Partner/Manager Signatory's ry's Title/Office The foregoing instrument was admowledg before rrpe.thhiis 1�1 day of NW k ,201'd,by Wa4d as 1 ` V (type of a ority,e.g.,officer,trustee,attorney in fad)for fAPkk-A'f (name fparty on.behalf mom Went a executed). �A�f frG////��rsonaily Knowr�`R—R Produced Identification❑ Notary Signature Ty/ i� of Identcetion Produced Name(Print C� r •A `Wt M��bt2_I t SeQ O GG�3� C z ' .'.,• Pula.,Val� �. O %, TATE OF ��rrrfirrrtrtttt,%►\"wpdata/bos/noficecommencement_pc053048 ' � � .. t} V _ i.. J Bailey Contracting-5023 Summerhill Dr-2,360 sq ft Column Es SQ. FEET PRICE MAIN OR LIVING: 2,360 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 265,854.00 FEE SHEET $ 1,370.00 ADDRESS $ 30.00 DRIVEWAY $ 45.00 BUILDING: $ 1,472.40 ELECTRICAL: $ ' 308.25 PLUMBING: $ 205.50 MECHANICAL: $ 143.85 SUB-TOTAL $ 2,130.00 TOTAL $ 2,130.00 SEWER: $ 2"090.00 WATER: $ 1,010.00 IRRIGATION: $ - TOTAL: $ 3,100.00 WATER METER:1 $ 473.78 IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 6,257.13 PARK IMPACT FEES $ 769.56 SIF'S: $ 7,128.00 100.0% $ 7,128.00 1.0% $ 71.28 TOTAL: $ 7,199.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 17,857.97 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: R0318106 Builder Name: Street: 5023 Summer Hill Dr. Permit Office: City of Z phyrhills City,State,Zip: Zephyrhills,FL,33542 Permit Number: I' .t 1 Owner: Butterfield Investments, Inc. Jurisdiction: 0 •kr`' Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1642.7 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Ext Insul,Exterior R=5.0 1381.30 ftz b.Frame-Wood,Adjacent R=13.0 261.33 ftz 3. Number of units,if multiple family 1 c.N/A R= ft 4. Number of Bedrooms 4 d.NIA R= f 2 5. is this a worst case? No 10.Ceiling Types (1780.0 sqft.) Insulation Area a.Under Attic(Vented) R=,30.0 1780.00 ftz 6. Conditioned floor area above grade(ftz) 1780 b.N/A R= ftz Conditioned floor area below grade(ftz) 0 c.NIA R= ft2 11.Ducts R ftz 7. Windows(179.0 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Garage 6 225 a. U-Factor: Dbl,U=0.65 144.00 ftz SHGC: SHGC=0.35 b. U-Factor: Dbl,default 35.00 ftz 12.Cooling systems kBtu/hr Efficiency SHGC: Clear,default a.Central Unit 32.6 SEER:15.00 c. U-Factor: NIA ftz SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor. N/A ftz a.Electric Heat Pump 34.0 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 2.369 ft. Area Weighted Average SHGC: 0.418 14.Hot water systems 8. Floor Types (1780.0 sqft.) Insulation Area a.Electric Cap:50 gallons EF:0.970 a.Slab-On-Grade Edge Insulation R=0.0 1780.00 ftz b. Conservation features b.N/A R= ftz None c.N/A R= ftz 15.Credits None Glass/Floor Area: 0.101 Total Proposed Modified Loads: 57.99 PASS Total Baseline Loads: 58.09 I hereby certify that the plans and specifications covered by Review of the plans and 'THE Sr this calculation are in compliance with the Florida Energy specifications covered by this k�� fiOR Code. / calculation indicates compliance with the Florida Energy Code. ++++, '-. =y ;,•� PREPARED BY: Before construction is completed DATE: 03-11-2018 this building will be inspected for y compliance with Section 553.908 I hereby certify that this building,as designed,is in compliance Florida Statutes. with the Florida Energy Code. ®D yvEZ�� OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - - Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. _ -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). 3/9/2018 3:47 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 6 FORM R405-2017 PROJECT. Title: R0318106 Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 1780 Lot# Owner Name: Butterfield Investments, Inc. Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: No - PlatBook: Builder Name: Rotate Angle: 0 Street: 5023 Summer Hill Dr. Permit Office: City of Zephyrhills Cross Ventilation: No County: Pasco Jurisdiction: Whole House Fan: No City,State,Zip: Zephyrhills, Family Type:. Single-family FL, 33542 New/Existing: New(From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days .Moisture Range FL,Tampa FL TAMPA INTERNATI 39 91. 70 75 645.5 54 Medium BLOCKS Number Name Area Volume 1 Entire House 1780 14240 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 MBedRm 198 1584 No 2 1 1 Yes Yes Yes 2 BedRmDen 153 1224 No 1 1 1 Yes Yes Yes J 3 MWic 70 560 No 0 1 Yes Yes Yes 4 Utility 49 392 No 0 1 Yes Yes Yes 5 BathRm 44 352 No 0 1 Yes Yes Yes 6 BedRm2 139 1112 No 0 1 1 Yes Yes Yes 7 Foyer 76 608 No 0 1 Yes Yes Yes 8 Hall 35 280 No 0 1 Yes Yes Yes 9 BedRm3 143 1144 No 1 1 1 Yes Yes Yes 10 LivingDining 504 4032 No 0 1 Yes Yes Yes 11 Kitchen 260 2080 Yes 0 1 Yes Yes Yes 12 MBathRm 109 872 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio MBedRm __28.3 ft 0 198 ft2 0 0�' 1 i 2 Slab-On-Grade Edge Insulatio BedRmDen 21.7 ft 0 153 ft2 0 0 1 3 Slab-On-Grade Edge Insulatio MWic 1 ft 0 70 ft2 0 0 1 4 Slab-On-Grade Edge Insulatio Utility 5.7 ft 0 49 ft2 0 0 1 5 Slab-On-Grade Edge Insulatio BathRm 5.3 ft 0 44 ft2 0 0 1 3/9/2018 3:47 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 6 FORM R405-2017 FLOORS J # Floor Type Space . Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 6 Slab-On-Grade Edge Insulatio BedRm2 34.3 ft 0 139 ft2 0 0 1 7 Slab-On-Grade Edge Insulatio Foyer 5.7 ft 0 76 ft2 0 0 1 8 Slab-On-Grade Edge Insulatio' Hall 2.3 ft 0 .35 ft2 0 0 1 9 Slab-On-Grade Edge Insulatio BedRm3 10.7 ft 0 143 ft2 0 0 1 10SIab-On-Grade Edge Insulatio. LivingDining 39 ft 0 504 ft2 0 0 1 11Slab-On-Grade Edge Insulatio Kitchen 10.3 ft 0 260 ft2 - 0 0 1 12SIab-On-Grade Edge Insulatio MBathRm 9.3 ft 0 109 ft2 0 0 1 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 : Hip Composition shingles 1928 ft2 0 ft2 Medium 0.65 No 0.9 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 1780 ft2 N N CEILING # Ceiling Type; Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) MBedRm 30 Blown 198 ft2 0.1 Wood 2 Under Attic(Vented) BedRmDen 30 _ Blown 153 ft2 0.1 Wood 3 Under Attic(Vented) MWic 30 Blown 70 ft2 0.1 Wood 4 Under Attic(Vented) Utility 30 Blown 49 ft2 0.1 Wood 5 Under Attic(Vented) BathRm 30 Blown 44 ft2 0.1 Wood 6 Under Attic(Vented) BedRm2 30 Blown 139 ft2 0.1 Wood 7 Under Attic(Vented) Foyer 30 Blown 76 ft2 0.1 Wood 8 Under Attic(Vented) Hall 30 Blown 35 ft2 0.1 Wood 9 Under Attic(Vented) BedRm3 30 Blown 143 ft2 0.1 Wood 10 Under Attic(Vented), LivingDining 301 Blown 504 ft2 0.1 Wood 11 Under Attic(Vented) Kitchen 30 Blown 260 111:2 0.1 Wood 12 Under Attic(Vented) MBathRm 30 Blown 109 ft2 0.1 Wood WALLS Adjacent Cavity ity Width Height Sheathing Framing Solar Below We Ft In Et In Area R-Alaille Eractoon Ahsor Grade% 1 S Exterior Concrete Block-Ext lnsuMBedRm 5 15 8 8 0 125.3 ft2 0 0 0.3 0 2 W Exterior Concrete Block-Ext lnsuMBedRm 5 12 8 8 0 101.3 ft2 0 0 0.3 0 3 N Exterior Concrete,Block-Ext InsiDedRmDen 5 8 8 8 0 69.3 ft2 0 0 0.3 0 4 W Exterior Concrete Block-Ext Insfi1edRmDen 5 13 0 8 0 104.0 ft2 0 0 0.3 0 3/9/2018 3:47 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 6 FORM R405-2017 WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below t To N►aU�ype Spate-- R-value Ft In Ft In Area R-vailie-Fraction Ahsor Grade/ _5 S Exterior Concrete Block-Ext Insul Utility 5 5 8 8 0 45.3 ft2 0 0 0.3 0 _6 E Garage Frame-Wood Utility 13 8 8 8 0 69.3 ft2 0 0.25 0.01 0 _ 7 N Garage Frame-Wood Utility 13 2 8 8 0 21.3 ft2 0 0.25 0.01 0 8 N Exterior Concrete Block-Ext InsulBathRm 5 5 4 8 0 42.7 ft2 0 0 0.3 0 _ 9 N Exterior Concrete Block-Ext InsulBedRm2 5 10 8 8 0 85.3 ft2 0 0 0.3 0 10 E Exterior Concrete Block-Ext InsulBedRm2 5 13 0 8 0 104.0 ft2 0 0 0.3 0 11 S Exterior Concrete Block-Ext InsulBedRm2 5 10 8 8 0 85.3 ft2 0 0 0.3 0 12 E Exterior Concrete Block-Ext Insul Foyer 5 5 8 8 0 45.3 ft2 0 0 0.3 0 13 S Garage Frame-Wood Foyer 13 10 4 8 0 82.7 ft2 0 0.25 0.01 0 14 E Exterior Concrete Block-Ext Insul Hall 5 1 4 8 0 10.7 ft2 0 0 0.3 0 15 S Exterior Concrete Block-Ext Insul Hall 5 1 0 8 0 8.0 ft2 0 0 0.3 0 16 N Exterior Concrete Block-Ext InsulBedRm3 5 10 8 8 0 85.3 ft2 0 0 0.3 0 17 N Exterior Concrete Block-Ext InslJlvingDining 5 25 0 8 0 200.0 ft2 0 0 0.3 0 18 W Exterior Concrete Block-Ext InsU[vingDining 5 14 0 8 0 112.0 ft2 0 0 0.3 0 19 S Exterior Concrete Block-Ext Insul Kitchen 5 10 4 8 0 82.7 ft2 0 0 0.3 0 _20 E Garage Frame-Wood Kitchen 13 11 0 8 0 88.0 ft2 0 0.25 0.01 0 21 S Exterior Concrete Block-Ext InsuMBathRm 5 9 4 8 0 74.7 ft2 0 0 0.3 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 E Insulated Foyer None .46 3 7 21 ft2 2 E Insulated Utility None .46 3 7 21 ft2 WINDOWS Orientation shown is the entered,Proriosed orientation. Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 W 2 TIM Low-E Double Yes 0.65 0.35 N 30.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 2 W 4 TIM Low-E Double Yes 0.65 0.35 N 15.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 3 E 10 TIM Low-E Double Yes 0.65 0.35 N 15.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 4 N 16 TIM Low-E Double Yes 0.65 0.35 N 15.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 5 N 17 TIM Low-E Double Yes 0.65 0.35 N 48.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 6 W 18 TIM Low-E Double No ; 0.65 0.7 N 35.0 ft2 8 ft 0 in 0 ft 6 in Drapes/blinds Exterior 5 7 S 19 TIM Low-E Double Yes 0.65 0.35 N 12.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 8 1 S 21 TIM Low-E Double Yes 0.65 0.35 N 9.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5 3/g/2018 3:47 PM EnergyGaugeO USA-FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 6 FORM R405-2017 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 439.2311 ft2 439.2311 ft2 64 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1661.3 91.2 171.52 .2669 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 34 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity, Air Flow SHR Block Ducts 1 Central Unit/ Split SEER:15 32.6 kBtu/hr' 1087 cfm 0.73 1 sys#1 (. HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 50 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage- Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS —Supply— —Return— Air CFM 25 CFM25 HVAC# # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 225 ft2 Attic 150 ft2 Default Leakage Garage (Default) (Default) 1 1 3/9/2018 3:47 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 6 FORM R405-2017 TEMPERATURES Programabl[e Thermostat:N [[ Ceiling Fans: Heatug Sep Oct Nov Dec ing l Jan Feb [X�Mar Apr May Ma ri Apr y Jun ri Jul A Jun Jul Aug Sep WOct Nov Dec Venting [[ I Jan Feb [[X]Mar Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 —78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 ' 80 78 78 78 78 78 78 78 78 Heating(WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating(WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 3/9/2018 3:47 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 6 of 6 FORM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDFX* = 100 The lower the EnergyPerformance Index, the more efficient the home. 5023 Summer Hill Dr., Zephyrhills, FL, 33542 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Ext Insul,Exterior R=5.0 1381.30 ft2 b.Frame-Wood,Adjacent R=13.0 261.33 ft. 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types Insulation Area a.Under Attic(Vented) R=30.0 1780.00 ft2 6. Conditioned floor area(ft2) 1780 b.N/A R= ft2 7. Windows" Description Area c.N/A R= ft2 a. U-Factor. Dbl,U=0.65 144.00 ft2 11.Ducts R ft2 SHGC: SHGC=0.35 a.Sup:Attic,Ret:Attic,AH:Garage 6 225 b. U-Factor: Dbl,default 35.00 ft2 SHGC: Clear,default 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a.Central Unit 32.6 SEER:15.00 SHGC: d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 34.0 HSPF:8.50 Area Weighted Average Overhang Depth: 2.369 ft. Area Weighted Average SHGC: 0.418 8. Floor Types Insulation Area 14.Hot water systems Cap:50 gallons a.Slab-On-Grade Edge Insulation R=0.0 1780.00 ft2 a.Electric ns EF:0.97 b.N/A. R= ft2 c.N/A R= ft2 b. Conservation features _ None 15.Credits None I certify that this home has complied with the Florida Energy Efficiency Code for Building EKE sr Construction through the above energy saving features which will be installed (or exceeded) `�-Fo in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. 1� ,ow�•• ;� vo Builder Signature: Date: Address of New Home: Sv23 Sin^ I �� �� City/FL Zip:`7elplIq r�jl)s -r_tl boo WE *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy-efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at ' techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 3/9/2018 3:48 PM EnergyGauge®USA-FlaRes2017 -Section R405.4.1 Compliant Software Page 1 of 1 Job: R0318106 - Wrlghtsofta Manual S Compliance Report Date: 0310812018 Entire House By: MKC i Teri Butterfield 37516 CookAve,Dade City,FL Project • • For. Butterfield Investments,Inc. 5023 Summer Hill Dr.,Zephyrhills,FL 33542 Cooling Equipment Design Conditions Outdoor design DB: 91.4°F Sensible gain: 23608 Btuh Entering coil DB: 78.6°F Outdoor design WB: 77.2°F Latent gain: 4827 Btuh Entering coil WB: 64.2°F Indoor design DB: 75.0°F Total gain: 28434 Btuh Indoor RH: 50% Estimated airflow: 1087 cfm Manufacturer's Performance Data at Actual Design Conditions Equipmenttype: SplitASHP Manufacturer. Goodman Mfg.or Egv. Model: GSZ16036+AVPTC36 Actual airflow: 1087 cfm Sensible capacity: 23798 Btuh 101%of load Latent capacity: 8802 Btuh 182%of load Total capacity. 32600 Btuh 115%of load SHR: 73% Heating Equipment Design Conditions Outdoor design DB: � 42.9°F Heat loss: 20987 Btuh Entering coil DB: 69.1°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipmenttype: SplitASHP Manufacturer. Goodman Mfg.or Eqv Model: GSZ16036+AVPTC36 Actual airflow: 1087 cfrn Output capacity: 34000 Btuh 162%of load Capacity balance: 31 OF Supplemental heat required: 0 Btuh Economic balance: -99 OF Backup equipment type: Sec strip Manufacturer. Model: Actual airflow: 1087 c6n Output capacity: 10.0 kW 163%of load Temp.rise: 29 OF Meets all requirements ofACCA Manual S. wrightsoft- 201 8-Mar-09 15:04:10 MgttSuite@Uriversal 20l8 l8.0.10 RSU20773 Page 1 AC ,K ...ark miem3181o6-Surrner Hill Dr1R0318106.mp Calc=MJ8 FrortDoorlaces:E .Pro tSumma Job: R0318108 - - wrightsoft- ec ry Date: 0310812018 Entire House Br. MKc Teri Butterfield 37516 Cook Ave,Dade CO,FL Proeect Information For. Butterfield Investments Inc. 5023 Summer Hill Dr.,Yephyrhills,FL 33542 Notes: Load calculation was obtained from a digital copy of the CAD drawing. Design Information Weather. Tampa IntIAP,FL,US Winter DesignConditions Summer Design Conditions Outside db 43 OF" Outside db 91 OF Inside db 70 OF Inside db 75 OF Design TD 27 OF Design TD. 16 OF Daily range L Relative humidity 50 % Moisture difference 54 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 16769 Btuh Structure 16038 Btuh Ducts 4218 Btuh Ducts 6204 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 1365 Btuh Piping 0 Btuh Equipment load 20987 Btuh Use'manufacturers data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 23608 Btuh Method - Simplified Latent Cooling Equipment Load Sizing Construction quality _ Average Fireplaces 0 Structure 2989 Btuh Ducts 1838 Btuh Central vent(0 cfm) 0 Btuh Heating Coolingg (none) Area(fF) 1781 1781 Equipment latent load 4827 Btuh Volume(ft� 14245 14245 Air changesAlour 0.38 0.20 Equipment Total Load(Sen+Lat) 28434 Btuh Equiv.AVF(cfm) 90 47 Req.total capacity at 0.73 SHR 2.7 ton Heating Equipment Summary Cooling Equipment Summary . Make Goodman Mfg.or Eqv. Make Goodman Mfg.or Eqv. Trade Split HP Trade Split HP Model GSZ16036 Cond GSZ16036 AHRI ref 8331286 Coil AVPTC36 AHRI ref 8331286 Efficiency 8.5 HSPF Efficiency 12.5 EER,15 SEER Heating Input Sensible cooling 23798 Btuh Heating output 34000 Btuh@47°F Latentcooling 8802 Btuh Temperature rise 28 OF Total cooling 32600 Btuh Actual air flow 1087 cfm Actual air flow 1087 dm Air flow factor 0.052 c rnBtuh Air flow factor 0.049 cb Btuh Static pressure - 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.83 Capacity balance point=31 OF Backup: Aux Heat Input=10 kW, Output=34121 Btuh,100 AFUE Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrigF�tsoft��~ -._•..a•. -....�.-..---..-. Right-SriteOUriversa1201818.0.10 RSU 2018-Mar-0915:04:1020773 Page 1 orkF1e1R0318106-SurvnerMllDrU20318106np Calc=MJS Frort Door faces:E htsoft wri • Ri ht-M Worksheet Job: R0318106 9 g Date: 0310812018 Entire House By: MKC Teri Butterfield 37516 CookAve,Dade City,FL 1 Room name Entire House IvBedRm 2 Exposed Kell 172.7 ft 28.3 ft 3 Room height 8.0 ft 8.0 ft healYcool 4 Room dimensions 12.7 x 15.7 ft 5 Room area 1780.7 198.4 IF Ty Construction U-value Or HTM Area (ft� Load Area Load number (Btuhllt;-9 (B or perimeter (ft) (Bluh) or perimeter (ft) (Btuh) Heat Cool Gross NIM Heat Cool Gross NIPS Heat Cool 6 %I 13A5o s 0.125 n 3.39 247 .483 420 1422 1036 0 0 0 0 L_(G 4A3.2ob 0.650 n 17.61 14.61 48 0 846 701 0 0 0 0 4A3-2ob OBW n 17.61 14.61 15 0 254 219 0 0 0 0 V�J 13A5ocs 0.125 a 3.39 2.47 160 w491 358 0 0 0 0 11 L-G 4A3-2ob 0.650 a 17.61 35.98 15 0 264 540 0 0 0 0 V�! 13A-5ocs 0.125 s 3.39 247 421 400 1356 988 125 125 425 309 E-C 4A3-2ob 0.650 a 17.61 14.61 9 9 159 131 0 0 0 0 t-G 4A3-2ob 0.650 s 17.61 14.61 12 12 211 175 0 0 0 0 �✓ 13A 5ocs 0.125 w 3.39 247 317 237 804 586 101 71 242 176 1-f1OD-b 0.690 w 18.70 12-78 35 31 654 447 0 0 0 0 2 4A3-2ob 0.650 w 17.61 35.98 45 0 793 1619 30 0 528 1079 P 12C-Ow 0.091 - 2.47 1.46 261 261 644 382 0 0 ' 0 0 C 1613-30ad 0.032 - 0.87 1.74 -1781 1781 1544 3103 198 198 172 346 F 22A[pI 0.989 - 26.80 0.00 1781 173 4628 0 198 28 759 0 r • 6 c)AED exo arson 876 439 Envelope lossngain 14080 11162 2126 2349 12 a) Infiltration 2688 856 441 141 b) Room ventilation 0 0 0 0 13 Inlemalgains: Oowpants@ 230 4 920 2 460 Appliancesrother 3100 1 0 Subtotal(lines6 to 13) 16769 16038 2567 2950 Less external load 0 0 0 0 Lesstransfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 16769 16038 2587 2950 15 Ductloads 25% 39% 4218 6204 259% 39%1 646 1141 Total room load 20987 22242 3213 4091 Air required(dm) 1 1087 1087 166 200 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. . _ i' ►- wrightsofft` 2018-Mar-0915.•04:10 Right-SUte@Uriverwl 20l8 l8.0.10 RSU20773 Page 1 'gy p` ...ork FIeRO318106-Summer Frill DrkR0318106.nip Calc=MJ8 Front Doorfaces:E wrightsoft• Right-A)Worksheet Job: R0318106 • ; Date: 03/0812018 Entire House By: MKC Teri Butterfield 37516 Cook Ave,Dade City,FL 1 Room name BedRmDen "Niic 3 R eight) 8.0 It 21.7 ft heat/000l 8.0 it ft heat/000l 4 Room dimensions 1.0 x 153.0 ft 1.0 x 70.2 ft 5 Room area 153.0 it2 702 ft Ty Construction U-value or HTM Area Load Area (ftz) Load number or perimeter (it) (Btuh) or perimeter (@) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross NOS Heat Cool 6 13A-5ocs 0.125 n 3.39 247 69 69 235 171 0 0 0 0 4A3-2ob 0.650 n 17.61 14.61 0 0 0 0 0 0 0 0 4A3-2ob 0.650 n 17.61 14.61 0 0 0 0 0 0 0 0 U�JL 13A-5ocs 0.125 a 3.39 247 0 0 0 0 0 0 0 0 11 -G 4A3-2ob 0.650 a 17.61 35.98 0 0 0 0 0 0 0 0 VJJ 13A-5ocs 0.125 s 3.39 247 0 0 0 0 0 0 0 0 L�-{G^ 4A3-2ob 0.650 s 17.61 14.61 0 0 0 0 0 0 0 0 4A3-2ob 0.650 s 17.61 14.61 0 0 0 0 0 0 0 0 VN 13A-5o s 0.125 w 3.39 2.47 104 89 301 220 0 0 0 0 L��G; 10D-b 0.690 w 18.70 12.78 0 0 0 0 0 0 0 0 4A3-2ob 0.650 w 17.61 35.98 15 0 264 540 0 0 0 0 P 12C-Osw 0.091 - 247 1:46 0 0 0 0 0 0 0 0 C 1613-30ad 0.032 - 0.87 1.74 153 153 133 267 70 70 61 122 F 22A-cpl 0.989 - 26.80 0.00 153 22 581 0 70 0 0 0 i 6 c)AED eumrsion 188 -5 Envelope losslgain 1514 1386 61 117 12 a) Infillration 337 107 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 0 - 0 Applianoeslother 500 0 Subtotal(lines6 to 13) 1851 2223 61 117 Lessextemalload 0 0 0 0 Lesstransfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1851 2223 61 117 15 Ductloads 25% 390/c 466 860 25°/a 39% 15 45 Total mom load 2317 3083 76 163 Air required(clm) 120 151 4 8 Calculations approved bMACCA to meet all requirements of Manual J 8th Ed. - wrlgFatsoft- 2018-Mar-0915:04:10 - - - - Right-Suite®Universal 201818.0.10 RSU20773 Page 2 orkFleVO318106-Summer Hit DOR0318106.np Catc=MA FrortDoorfaces:E -P -wrightsof , Right-M Worksheet Job: R0318106 Entire House Date: 0310812018 By: MKC Teri Butterfield 37516 CookAve,Dade City,FL 1 Room name Utility BathRm 2 E)POsedVall 5.7 ft 5.3 ft 3 Room height 8.0 It heaVOOol 8.0 It heaVood 4 Room dimensions 8.7 x 5.7 It 8.3 x 5.3 ft 5 Room area 49.1 ft2 44A ft? Ty Construction U-value Or HTM Area (ft� Load Area (t) Load number (BUiRL°F) or perimeter (ft) (Btrih) or perimeter (ft) (BUh) Heat Cod Gross N/P!S Heat Cod Gross NIPS Heat Cool 6 13X5ocs 0.125 n 3.39 247 0 0 0 0 43 43 145 105 4A3.2ob 0.650 n 17.61 14.61 0 0 0 0 0 0 0. . 0 4A3.2ob _ 0.650 n 17.61 14.61 0 0 0 •0 0 0 0 0 1�I 13A5ocs 0.125 a 3.39 247 0 0 0 0 0 0 0 0 11 t.--G 4A3-2ob 0.650 a 17.61 35.98 0 0 0 0 0 0 0 0 Vp/ (G, 13A-5ocs 0,125 s 3.39 247 45 45 154 112 0 0 0 0 LI-_. 4A3-2ob 0.650 s 17.61 14.61 - 0 0 0 0 0 0 0 i 0 4A3.2ob 0.650 s 17.61 14.61 0 0 0 0 0 0 0 . 0 lqJ 13A5ocs 0.125 w 3.39 247 0 0 0 0 0 0 0 0 � G 10D-b 0.690 w 18.70 1278 0 0 0 0 0 0 0 0 T 4A3-2ob 0.650 w 17.61 35.98 0 0 0 0 0 0 0 0 P 12C-O 0.091 - 247 1.46 91 91 224 132 0 0 0 0 C 161330ad 0.032 - 0.97 1.74 49 49 43 86 44 44 39 77 F 22A-0 -0.989 26.80 0.00 49 6 -152 0 44 5 143 0 6 -c)AED exurson -34 -8 Ernelope loss7gain 572 296 325 174 12 a) Infiltration 88 28 83 26 b) Room ventilation 0 0 0 0 13 Intemaigairm Oowpants@ 230 U 0 0 0 Applianceslother 500 0 Subtotaf(lines6tO13) 660 824 409 201 Lessedemalload 0 0 0 0 Lesstransler 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 660 824 409 201 15 Ductloads 25% 39% 166 319 25% 39% 103 78 Total room load 826 1143 _ 512 279 Air required(cfm) 43 56 1 271 14 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. �}+- wria�f�tsoTt- 201 8-Mar-09 15.04:10 P. -- - "-- Right-Sute®Uriversal201818.0.10RSU20773 Page orkReM318106-Sumrer Hill DrAR0318106np Calc=MJe Frort Door faces:E -�+- wrightsoft• Right-JO Worksheet Job: R0318106 Entire House Bate: 03/08/2018 By: MKC Teri Butterfield l _ 37516 CookAve,Dade City,FL 1 Room name BedRm2 Foyer 2 Exposed Kell 34.3 ft 5.7 ft 3 Room height &0 ft heaVood 8.0 ft heatbool 4 Room dimensions 13.0 x 10.7 -It 5.7 x 13.3 It 5 Room area 138.7 fF 75.6 fP Ty Consi xtion U-value Or HTM Area (fe) Load Area (ft) Load number (BivhAP9 or Perimeter (ft) (Btuh) or perimeter M (Bfuh) Heat Cad Gross N/P/S Heat Cool Gross N/P/S Heat Coo! 6 VN 13X6= 0.125 n 3,39 2.47 85 85 289 211 0 0 ­0 0 0 {L-CG 4A3.2ob 0.650 n 17.61 14.61 0 0 0 0 0 0 0 0 4A3-2ob 0.650 n 17.61 14.61 0. 0 0 0 0 0 0 0 W 13A-5ocs 0.125 a 3.39 2.47 104 89 301 220 45 45 154 112 11 L-G 4A3-2ob 0.650 a 17.61 35.98 15 0 284 - 540, 0 0 0 0 13A Sots 0.125 s 3.39 247 85 85 289 211 " . 0 0 0 .'. 0 4A3-2ob 0.650 S 17.61 14.61 0 0 0 0 0 0 r 0 0 4A3-2ob 0.650 s . 17.61 14.61 0 0 0 0 0 0 0 0 �1 13A-5005 0.125 w 3.39 247 0 0 0 0 0 0 0 0 �--G 10D-b 0.690 w 18.70 1278 0 0 0 0 0 0 0 0 IL' 4A3-2ob 0.850 w 17.61 _ 35.98 0 0 0 0 0 0 0 0 P 12C-0ser 0.091 - 247 1.46 0. 0 0 0 83 83 204 121 C 166-30ad 0.032 - 0.87 1.74 139 139 120 242 76 76 66 132 F . 22A[pl 0.989 - 26.80" 0.00 139,.- 34 920 0 76 - 6 . 152 0 L_ • 6 0)AEDemrson 102 -16 Envelope loss(gain 2184 1524 575 ' 349 12 a) Infiltration 535 170 88 28 b) Room ventilation 0 0 1 0 0 13 Intemalgains: OOoupants@ 230 0 0 0 0 Applianordb1t r - 0 0 Subtotal(lines 6tD13) 2719 1694 663 377 Less Mdemalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal , 2719 1694 663 377 15 Ductloads 25% 390/b 684 655 25% 39%1 167 146 Total room load 3403 2350 830 523 Air required(dm) 176 115 43F 26 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. �}i- wrigFetsoTt- 2018-Mar-09/15:04:10 I&GA - _- R igttSriteD Uriversal 201818.0.10 RSU20773 Page 4 orkFleIR0318106-Sunmer Hill Dr1R0318106.np Cale=MJ8 Frort Door faces,E -��- wriglhtsoft, RighW@ Worksheet Job: R0318106 Entire House Date: 03/0812018 By: MKC Teri Butterfield 37516 CookAve,Dade City,FL 1 Room name Hall BecIRm3 2 Ej�Dc�dy�pJ� 23 it10.7 It 3 Room height 8.0 It heaVbool 8.0 It heaV000l 4 Room dimensions 1.0 x 35.3 It 1.0 x 142.8 ft 5 Room area 35.3 fP 1428 t12 Ty Conshuclion U-value Or HTM Area (ftF) Load Area (M Load number (BtuhfiF-*q (Btuh4n or perimeter (it) (Stuh) or perimeter (11) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross WP/S Heat Cool 6 vN 13A-5ocs 0.125 n 3.39 2.47 0 0 0 0 85 70 238 174 t{-�G 4A32ob 0.650 n 17.61 14.61 b 0 0 0 0 0 0 0 4A3.2ob 0.650 n 17.61 14.61 0 0 0 0 15 0 284 219 yV 13A-5ocs 0.125 a 3.39 247 11 11 36 26 0 0 0 0 11 L--G 4A3-2ob 0.650 a 17.61 35.98 0 0 0 0 0 0 0 0 13A-5ocs 0.125 s 3.39 2-47 8 8 27 20 0 0 0 0 4A32ob 0.650 s 17.61 14.61 0 0 0 0 0 0 0 0 4A3-2ob 0.650 a 17.61 14.61 0 0 0 0 0 0 0 0 13A-5ocs 0.125 w 3.39 2.47 0 0 0 0 0 0 0 0 10D-b 0.690 w 18.70 12.78 0 0 0 0 0 0 0 0 1:f2 4A3-2ob 0.650 w 17.61 35.98 0 0 0 0 0 0 0 0 P 12C-Osa 0.091 - 2.47 1.46 0 0 0 0 0 0 0 0 C 1613-30ad 0.032 - 0.87 1.74 35 35 31 62 143 143 124 249 F 22A-c pl 0.989 - 26.80 0.00 35 2 63 0 143 11 286 0 6 c)AED excursion -5 -37 Envelope loss/gain 156 103 912 _ 605 12 a) Infiltration 36 12 166 53 b) Roan ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 1 230 Applianceslother 0 0 Subtotal(lines 6 to 13) 1 193 114 1078 888 Less extemalload 0 0 0 0 Lesstransrer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 193 114 1076 888 15 Duct loads 25% 39% 48 44 25% 39% 271 343 Total room load 241 159 1350 1231 Air required(c5n) 12 8 701 60 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. -➢�}.+ wr➢gFntsoT#- 2018-Mar-0915:04:10 - Riglt Sute®Uriversal 201818.0.10 RSU20773 Page 5 orkF1eW0318106-Summer HillDr1R0318106.rup Calc=MJ8 Front Door faces:E wrightsoft• Rig ht-JO Worksheet Job: R0318106 Date: 0310812018 Entire House By: MKC Teri Butterfield 37516 Cook Ave,Dade City,FL 1 Room name LtvingDtning Krtdlen 2 EVosedwali 39.0 ft 10.3 ft 3 Room height 8.0 ft heat/cool 8.0 ft heatlaool 4 Room dimensions 1.0 x 503.9 ft 1.0 x 260.3 ft 5 Room area 503.9 ft2 260.3 if Ty I Construclion U-value Or HTM Area (ft�, Load Area (ft2) Load number (Btuhd-'n (Btu or perimeter (ft) (Bhrh) or perimeter (11) (Btuh) Heat Cool Gross NIPS Heat Cool Gross NIP/S Heat Cod- 6 13A-5ocs 0.125 n 3.39 247 200 152 515 375 0 0 0 0 4A3.2ob 0.650 n 17.61 14.61 48 0 846 701 0 0 0 0 4A3-2ob 0.650 n 17.61 14.61 0 0 0 0 0 0 0 0 13A5ocs 0.125 a 3.39 2.47 0 0 0 0 0 0 . 0 0 11 4A3-2ob 0.650 a 17.61 35.98 0 0 0 0 0 0 0 0 VJd 13A-5ocs 0.125 s 3.39 2.47 0 0 0 0 83 71 239 174 4A3-2ob 0.650 s 17.61 14.61 0 0 0 0 0 0 0 0 4A3-2ob 0.650 S 17.61 14.61 0 0 0 0 12 12 211 175 Val 13A-5ocs 0.125 w 3.39 247 112 77 261 190 0 0 0 0 � ::G 10D-b 0.690 w 18.70 1278 35 31 654 447 0 0 0 0 L-G 4A3-2ob 0.650 w 17.61 35.98 0 0 0 0- 0 0 0 0 P 12C-0s v 0.091 - 2.47 1.46 0 0 0 0 88 88 217 129 C 168-30ad 0.032 - 0.87 1.74 504 504 437 878 260 260 225 454 F 22A-cpl 0.989 - 26.80 0.00 504 39 1045 0 260 10 277 0 6 c)AEDexwrson 359 -87 Envelopeloss(gain 3758 2951 1170 845 12 a) Infiltration 607 193 161 51 b) Room ventilation 0 0 1 0 0 13 Internal gains Ocwpants@ 230 0 0 0 0 Appliancestaltw 900 1200 Subtotal(lines6 to 13) 43651 4044 1331 2097 Less extemalload 0 0 0 0 estranger 0 0 0 0 Redisf ibution 0 0 0 0 14 Sublotal 4365 4044 1331 2097 15 DUdloads 25% 39% 1098 1564 259/6 39% 335 811 Total room load 5463 5609 1666 2908 Air required(c1m) 283 274 86 142 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. _ F wrigFstsoft- 2018-Mar-0915..04:10 Right-Suiteg Universal 201818.0.10 RSU20773 Page 6 ACCK orkFile1R0318106-SumrerRilDrIR0318106.nip Calc=MJB FrortDoorfaces:E �+ wrightsoW ` , Right-JO Worksheet Job: R0318106 Entire House Date: 0310812018 By: MKC Teri Butterfield 37516 CookAve,Dade City,FL 1 Room name NBaMRm 2 F)POsed v dl 8.0 ft 9.3 It heaVo�d 3 Room height 11.7 x 9.3 It Room dimensions 5 Room area 108.9 11, Ty Conslnxtioi U-value Or HTM Area (fF) Load Area Load number (BtuhlftL9 (Bhrhfin or- perimeter (19 (Bluh) or perimeter Heat Cool Gross N/P/S Heat Cod Gross N/P/S Heat Cool 6 13A5ocs 0.125 n 3.39 247 0 0 0 0 4A3-2ob 0.650 n 17.61 14.61 0 0 0 0 r--G 4A3-2Ab 0.650 n 17.61 14.61 0 0 0 0 yJ 13A5ocs 0.125 a 3.39 247 0 0 0 0 11 L--G 4A3-2ob 0.650 a 1761 35.98 0 0 0 0 11QJJ 13A-5ocs 0.125 s 3.39 2.47 75 66 222 162 4A3-2ob 0.650 s 17.61 14.61 9 9 159 131 4A3-2ob 0.650 s 17.61 14.61 0 - 0 0 0 V1J 13ASocs 0.125 w 3.39 2.47 0 0 0 0 )L—_-(f` 10D-b 0.690 w 18.70 12.78 0 0 0 0 4A3.2ob 0.650 w 17.61 35.98 0 0 0 0 P. 12C-Osw 0.091 - 247 1.46 -0 0 0 0 . C 1613-30ad 0.032 - 0.97 1.74 109 1,09 94 190 F. 22A-0 0.989 - 26.80 .. 0.00 . 109 9 250 0 6 c)AED e)cumot -21 Envelope losslgain 721 462 12 a) Infiltration 145 46 b) Roan ventilation 0 0 13 Internal gairm O=pants@ 230 0 0 Appliances/other - 0 Subtotal(Iines6 tD 13) 871 509 Lesse)demalload 0 0 Lesstransfer - 0 0 Redistribution 0 O 14 Subtotal 871 509 15 Ductloads 25% 39°/a 219 197 Total roan load T1090 705 Air required(dm) 56 34 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - wrigrstsoTt^ 2018•Mar-0915:04:10 - - Right Sute®Uriversal 201818.0.10 R8U20773 Page 7 ark ReW0318106-SurvnerKIIDrtR0318106np Calc=MJ8 Frort Door faces,E Jacqueline Ppoges From: City of Zephyrhills Support<support@zephyrhillsfl.zendesk.com> Sent: Thursday, April 12, 2018 8:25 AM To: Jacqueline Boges Subject: [Request received] 5,002-3:SummerjhillFdr,by#1.954,r1. ##- Please type your reply above this line -## Hello Jacqueline Boges, We are working to resolve your request promptly and will keep you updated. One of our Support Analysts will keep you updated on the progress of your request. Best Regards, FATHOM Support Team TO ADD ADDITIONAL COMMENTS, reply to this email or click the link below: https://zephyrhillsfl.zendesk.com/hc/requests/207857 ................................................................................................................................................................................................................................................................................................................................................................................. Jacqueline Boges Apr 12, 5:24 AM MST full service 5.0Z3 summerhill dr bp,#-]9541 Ovate-r sewer-and-water meter x:, This email is a service from City of Zephyrhills Support . 1 Jacavelinje Boges From: TQ Randolph (City of Zephyrhills Support)<support@zephyrhillsfl.zendesk.com> Sent: Thursday,April 12, 2018 5:04 PM To: Jacqueline Boges Subject: [FATHOM] Re: 5023 Sum merhill dr by#19541 ##- Please type your reply above this line -## Your request (#207857) has been updated. REPLY TO THIS EMAIL or click the link below: https://zephvrhillsfl.zendesk.com/hc/requests/207857 ...................................................................................................................................................................................................................................................................................................................................................................................... r TQ Randolph (City of Zephyrhills Support ) -- Apr 12, 2:03 PIA MST Account has been created, pending mapping. 990441-2988159 Best Regards, TQ1 FATHOM Support .......................................................................................................................................................................................................................................... ...................................................................... .................................... ..... Jacqueline Boges Apr 12, 5:24 AM MST full service 5023 summerhill dr by#19541 water sewer and water meter This email is a service from City of Zephyrhills Support . 1 5335 -8TH STREET (813)780-0020 CERTIFICATE OF OCCUPANCY Address: 5023 SUMMERHILL DR Owner: MANN MICHAEL ZEPHYRHILLS, FL. 2336 HERITAGE LAKES DR Subdiv: SUMMERHILL LAKELAND FL 33803-5408 Parcel: 12-26-21-0100-00000-0120 Work Type: 101-NEW CONST/SFR Construction Type: NOT APPLICABLE ❑ Sprinklers Use Classification: NOT APPLICABLE Permit Number: 19541 Date: 12/11 018 SSUED BY: U BUILDI OFFICIAL : WATER MUST BE CHANGED_OVER-WITHIN 10 DAYS OF ISSUANCE GARBAGE DEP,&I-T" MUST BE APPLIED FOR PRIOR TO ISSUANCE