HomeMy WebLinkAbout18-19551 CITY OF ZEPHYRHILLS
5335-8TH STREET
(813)780-0020 19551
BUILDING PERMIT SINGLE FAMILY RESIDENTIAL
PERMIT INFORMATION LOCATION INFORMATION
Permit#:19551 Issued: 4/11/2018 Address: 5130 20TH ST
Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL.
Class of Work: 101-NEW CONST/SFR Township: Range:
Proposed Use: NOT APPLICABLE Lot(s): Block: Section:
Sq. Feet: Est. Value: Book: Page:
Cost: 170,000.00 Total Fees: 2,483.78 Subdivision: CITY OF ZEPHYRHILLS
Amount Paid: 2,483.78 Date Paid: 4/11/2018 Parcel Number: 12-26-21-0000-02100-0000
CONTRACTOR INFORMATION OWNER INFORMATION
Name: BAILEY CONTRACTING LLC Name: BUTTERFIELD INVESTMENTS INC
Addr: 4209 GALL BLVD Address: 31325 AMBERLEA RD
ZEPHYRHILLS, FL. 33542 DADE CITY FL 33523-6225
Phone: (813)377-7395 Lic: Phone: 813-973-5250
Work Desc: CONSTRUCT SINGLE FAMILY 2,219 SQ FT
APPLICATION FEES
WATER METER RES 3/4" 473.78 BUILDING FEE 1,390.80 ELECTRICAL FEE 290.25
PLUMBING FEE 193.50 MECHANICAL FEE 135.45
oL#U1)3
Inspections Required
FOOTER 2ND ROUGH PLUMB MISC INSULATION CEILING
FOOTER BOND DUCTS INSULATED SEWER MISC.
ROUGH ELECTRIC LINTEL MISC MISC.
1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC.
DUCTS INSTALLED WATER MISC DRIVEWAY
PRE-SLAB SHEATHING MISC. MISC.
CONSTRUCTION POLE FRAME MISC. MISC.
REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES:
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing, consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance
with City Codes and Ordinances. NO.00CUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
CONTRACTO S SI NATURE PERMIT OFFI
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
Futile Ufl
., I ri .-
_
City of Zephyrhills
BUILDING PLAN REVIEW COMMENTS
Contractor/Homeowner:
Date Received: �q L
Site:
Permit Type: Z Zr 9
Approved w/no comments:❑ Approved w/the below comments: Denied w/the below comments: ❑
This comment sheet shall be kept with the permit and/or plans.
Kalvirt,Switze Tans Examiner Date Contrac or and/or Home ner
(Required when comments are present)
Jacqueline Boges
From: City of Zephyrhills Support<support@zephyrhillsfl.zendesk.com>
Sent: Thursday, April 12, 2018 8:12 AM
To: Jacqueline Boges
Subject: [Request received]5130 20th_`st p#=1i95591$—='��
Ic
##- Please type your reply above this line -##
Hello Jacqueline Boges,
We are working to resolve your request promptly and will keep you updated. One of our Support Analysts will keep
you updated on the progress of your request.
Best Regards,
FATHOM Support Team
TO ADD ADDITIONAL COMMENTS, reply to this email or click the link below:
https://zephyrhilisfl.zendesk.com/hc/requests/207855
......................................................................................................................................................................................................................................................................................................................................................................................
Jacqueline Boges
-- - Apr 12, 5:1 1 AM MST
fu�l�l fer=vice fo 30 20th st water, sewer and water meter. by#19551 v
This email is a service from City of Zephyrhills Support .
1
813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021
Building Department C, T
Date Received ' Phone Contact for Permitting d 13 q 7J _,:r�2�
Owner's Name Lt-tlL/�1��C! w1112_.J 1/Y 61-14S 11 Owner Phone Number /3 W-S 2,F6)
Owner's Address 2S -IPe'-1Z'L +��� c�l�i Owner Phone Number
Fee Simple Titleholder Name Owner Phone Number
Fee Simple Titleholder Address
JOB ADDRESS 5��a .90f s�/ee_/y LOST{#
SUBDIVISION PARCEL ID#
{ (OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED �I REPAIR NEW
CONSTRe SIGN Q Q DEMOLISH
INSTALL
PROPOSED USE I Y I SFR 0 COMM = OTHER
TYPE OF CONSTRUCTION n/d BLOCK Q FRAME = STEEL =
DESCRIPTION OF WORKI rZd✓ C-('�Ol�l
BUILDING SIZE o x 5-10 SO FOOTAGE ZZ I HEIGHT ,
BUILDING $ 10'000 VALUATION OF TOTAL CONSTRUCTION
=ELECTRICAL $ AMP SERVICE 2_60 E:Z/PROGRESS ENERGY = W.R.E.C.
=PLUMBING $ ��1
CHANICAL $ VALUATION OF MECHANICAL INSTALLATION
=GAS = ROOFING Q SPECIALTY = OTHER
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO
6, ,1 �n S-l/vLG f"
BUILDER � J ,� COMPANY r t:L+ °•
SIGNATURE REGISTERED Y/ W FEE CURREN Y/N p y
Address License# I CBC �C /
ELECTRICIAN COMPANY C7 Ci,
SIGNATURE REGISTERED I Y/ N FEE CURREN I Y/N
Address tr License# G7C10
PLUMBER COMPANY -�cfJ)U ) L- Lo 6 (•'6'r"'v 5 ��
SIGNATURE REGISTERED r r Y/ N FEE CURREN I Y/N
.L F
Address 0- - r 77Ye�`� LicenQse#
MECHANICAL COMPANY -JW,7 S: ,'ZO W/L If "I �/Y
SIGNATURE �) REGISTERED Y/ N FEE CURREN I Y/N
Address /Y �/✓ •� License# 9L 6Q
OTHER COMPANY
SIGNATURE REGISTERED Y/ N FEE CURREN
Address License#
' 1111111111111111111111111111111111111111111111111111111111111111111
RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction,
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities&1 dumpster,Site Work Permit for subdivisions/large projects
COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Fortes.R-O-W Permit for new construction.
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance
SIGN PERMIT Attach(2)sets of Engineered Plans.
"PROPERTY SURVEY required for all NEW construction.
Directions:
Fill out application completely.
Owner&Contractor sign back of application,notarized
If over$2500,a Notice of Commencement Is required. (AIC upgrades over$7500)
Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (copy of contract required)
Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage)
Driveways-Not over Counter if on public roadways..needs ROW
+ NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restrictions"
whidh may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any
applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or
contractors to undertake work,they may be required to be licensed in accordance with state and local regulations. If the
contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation
under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the
intended work,they are advised to contact the Pasco County Building Inspection Division--Licensing Section at 727-847-
8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign
portions of the"contractor Block"of this application for which they will be responsible. if you, as the owner sign as the
contractor,that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco
County.
TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of
use in existing buildings, or expansion of existing buildings,as specified in Pasco County Ordinance number 89-07 and
90-07, as amended. The undersigned also understands,that such fees,as may be due,will be identified at the time of
permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to
receiving a"certificate of occupancy"or final power release. If the project does not involve a certificate of occupancy or
final power release,the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact
fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended): If valuation of work is$2,500.00 or more,I
certify that 1, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's
Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs. if the applicant is someone
other than the"owner",I certify that I have obtained a copy of the above described document and promise in good faith to
deliver it to the"owner"prior to commencement.
CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work
will be done in compliance with all applicable laws regulating construction,zoning and land development. Application is
hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has
commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating
construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also
certify that I understand that the regulations of other government agencies may apply to the intended work,and that it is
my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to:
- Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands,Water/Wastewater Treatment.
- Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering
Watercourses.
- Army Corps of Engineers-Seawalls,Docks,Navigable Waterways.
- Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment,
Septic Tanks.
- US Environmental Protection Agency-Asbestos abatement.
- Federal Aviation Authority-Runways.
I understand that the following restrictions apply to the use of fill:
- Use of fill is not allowed in Flood Zone"V"unless expressly permitted.
- If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a
"compensating volume"will be submitted at time of permitting which is prepared by a professional engineer
licensed by the State of Florida.
- If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall
construction,I certify that fill will be used only to fill the area within the stem wall.
- If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties,the owner may be cited for violating
the conditions of the building permit issued under the attached permit application,for lots less than one(1)
acre which are elevated by fill,an engineered drainage plan is required.
If I am the AGENT FOR THE OWNER,I promise in good faith to inform the owner of the permitting conditions set forth in
this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work,
plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A
permit issued shall be construed to be a license to proceed with the work and not as authority to violate,cancel,alter,or
set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter
requiring a correction of errors in plans,construction or violations of any codes. Every permit issued shall become invalid
unless the work authorized by such permit is commenced within six months of permit issuance,or if work authorized by
the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced. An extension
may be requested,in writing,from the Building Official for a period not to exceed ninety(90)days and will demonstrate
justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFO RECORDING YOUR NOTICE OF COMMENCEMENT.
FLORIDA JURAT(F.S.117.03)
OWNER OR AGENT CONTRACTOR
Subscribed and sworn to(or affirmed)before mWtlis Subscribed and sworn to(or affirmed)before me this
by by
Who is/are personally known to me or has/have produced Who is/are personally known to me or has/have produced
as identification. as identification.
Notary Public Notary Public
Commission No. Commission No.
Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped
I
I
9
FORM R405-2017 '.
FLORIDA ENERGY EFFICIENCY CODE,-.-FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regla ion - Residential Performance Method
Project Name: R0318107 Builder-Name:
Street: 5130 20th St Permit Office: City f_Zephyrhills
City,State,Zip: Zephyrhills,FL,33542 Permit Number.
Owner: Butterfield Investments,Inc. Jurisdiction: 611600
Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2)
1. New construction or.existing New(From Plans) 9. Wall Types(1685.3 sqft.). Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Ext Insul,Exterior R=5.0 1434.70 ftz
b.Frame-Wood,Adjacent R=13.0 250.67 ftz
3. Number of units,if multiple family 1 c.N/A R= ftz
4. Number of Bedrooms 3 d.N/A R= ftz
5. Is this a worst case? No 10.Ceiling Types (1644.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1644.00 ftz
6. Conditioned floor area above grade(ftz) 1644 b.WA R= ftz
Conditioned floor area below grade(ftz) 0 c.N/A R= ftz
11.Ducts R ftz
7. Windows(108.7 sqft.) Description Area a.Sup:Attic,Ret:Attic,AH:Garage 6 225
a. U-Factor: Dbl,U=0.65 108.67 ftz
SHGC: SHGC=0.35
b. U-Factor. N/A ft= 12.Cooling systems kBtu/hr Efficiency •
SHGC: a.Central Unit 27.8 SEER:15.00
c. U-Factor: N/A ftz
SHGC: 13.Heating systems kBtu/hr Efficiency
d. U-Factor. N/A ftz a.Electric Heat Pump 28.0 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 4.088 ft.
Area-Weighted Average SHGC: 0,350 14.Hot water systems
8. Floor Types (1644.0 sqft.) Insulation Area a.Electric Cap:50 gallons
EF:0.970
a.Slab-On-Grade Edge Insulation R=0.0 1644.00 ftz b. Conservation features
b.N/A R= ftz None
c.N/A R= ftz 15.Credits None
Total Proposed Modified Loads: 51.11
Glass/Floor Area: 0.066 PASS
Total-Baseline Loads: 51.88
I hereby certify that the plans and specifications covered by Review of the plans and e-tyE Sok
T,1?
this calculation are in compliance with the Florida Energy specifications covered by thisa� ,,,-' ,FO�,
Code. calculation indicates compliance
&44.4 with the Florida Energy Code.
PREPARED BY: Before construction is completed
DATE: 03-11-2018 this building will be inspected for
compliance with Section 553.908 , .° •>
I hereby certify that this building,as designed,is in compliance Florida Statutes. �,i, `'
with the Florida Energy Code. 4 . COD
OWNER/AGENT: BUILDING F_F CI L:
DATE: - DATE:
- Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2).
3/11/2018 9:10 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5
FORM R405-2017
PROJECT
Title: R0318107 Bedrooms: 3 Address Type: Street Address
Building Type: User Conditioned Area: 1644 , Lot#
Owner Name: Butterfield Investments,Inc. Total Stogies: 1 Block/Subdivision:
#of Units: 1 Worst Case: No PlatBook:
Builder Name: Rotate Angle: 0 Street: 5130 20th St
Permit Office: City of Zephyrhills Cross Ventilation: No' County. Pasco
Jurisdiction: 611600 Whole House Fan: No City,State,Zip: Zephyrhills,
Family Type: Single-family FL, 33542
New/Existing: New(From Plans)
Comment:
CLIMATE
Design Temp Int Design Temp Heating Design Daily Temp
Design Location, TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,Tampa FL TAMPA_INTERNATI 39 91 70 75 645.5 54 Medium
BLOCKS
Number Name Area Volume
1 Entire House 1644 13152
SPACES '
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
1 Kitchen 308 2464 Yes 0 1 Yes Yes Yes
2 MBedRm 240 1920 No 2 1 1 Yes Yes Yes
3 MBathRm 120 960 No 0 1 Yes Yes Yes
4 Wic 84- 672 No 0 1 Yes Yes Yes
5 Utility 64 512 No 0 1 Yes Yes Yes'
6 Foyer 118 944 No 0 1 Yes Yes Yes
7 BedRm3 188 1504 No 1 1 1 Yes Yes Yes
8 BathRm 68 6" No 0 1 Yes Yes Yes
9 BedRm2 186 1488 No 1 1 1 Yes Yes Yes
10 Hall 32 256 No 0 1 Yes Yes Yes
11 LivingRm 236 1888 No 0 1 Yes Yes Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio Kitchen 46 ft 0 308 ft2 0 0 1
2 Slab-On-Grade Edge Insulatio MBedRm 40.7 ft 0 240 ft2 — 0 0 1
3 Slab-On-Grade Edge Insulatio MBathRm 9 ft 0 120 ft2 0 0 1
4 Slab-On-Grade Edge Insulatio Wic 7.7 ft 0 84 11:2 0 0 1
5 Slab-On-Grade Edge Insulatio Utility 1 ft 0 64 ft2 0 0 1
6 Slab-On-Grade Edge Insulatio Foyer Eft 0 118 ft2 -_- 0 0 1
3/11/2018 9:10 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5
FORM R405-2017
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
7 Slab-On-Grade Edge Insulatio BedRm3 14 ft 0 188 ft2 0 0 1
8 Slab-On-Grade Edge Insulatio BathRm 5.7 ft 0• 68 ftz 0 0 1
9 Slab-On-Grade Edge Insulatio BedRm2 36.7 ft 0 186 ft2 0 a 1
10SIab-On-Grade Edge Insulatio Hall 1 ft 0 32 ft2 0 0 1
11Slab-On-Grade Edge Insulatio LivingRm 13.7 ft 0 236 ft2 0 0 '1
ROOF
Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
# Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
1 Hip Composition shingles 1781 ft2 0 ft2 Medium 0.65 No 0.9 No 0 22.6
ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Vented 300 1644 ft2 N N
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
i
` 1 Under Attic(Vented) Kitchen 30 Blown 308 W 0.1 Wood
2 Under Attic(Vented) MBedRm 30 Blown 240 ft2 0.1 Wood
3 Under Attic(Vented) MBathRm 30 Blown 120 ft2 0.1 Wood
4 Under Attic(Vented) Wic 30 Blown 84 ftZ 0.1 Wood
5 Under Attic(Vented) Utility 30 Blown 64 ft2 0.1 Wood
6 Under Attic(Vented) Foyer 30 Blown 118 ft2 0.1 Wood
7 Under Attic(Vented) BedRm3 30 Blown 188 ft2 0.1 Wood
8 Under Attic(Vented) BathRm 30 Blown 68 ft2 0.1 Wood
9 Under Attic(Vented) BedRm2 30 Blown 166 ft2 0.1 Wood
10 Under Attic(Vented) Hall 30 Blown 32 ft2 0.1 Wood
11 Under Attic(Vented) LivingRm 30 Blown 235 ft2 0.1 Wood
WALLS'
Adjacent Space Cavity Width Height - Sheathing Framing Solar Below
1 N Exterior Concrete Block-Ext Insul Kitchen 5 23 8 8 0 189.3 ft2 0 0 0.3 0
2- E Exterior Concrete Block-Ext Insul Kitchen 5 13 0 8 0 104.0 ft2 0 0 0.3 0
I.
3 S Exterior Concrete Block-Ext Insul Kitchen 5 9 4 8 0 74.7 ft2 0 0 0.3 0
4 N Exterior Concrete Block-Ext InsuMBedRm 5 9 4 8 0 74.7 ft2 0 0 0.3 0
5 E Exterior Concrete Block-Ext InsuMBedRm 5 13 4 8 0 106.7 W 0 _ 0 0.3 0
6 S Exterior Concrete Block-Ext InsuMBedRm 5 18 0 8 0 144.6 ft2 0 0 0.3 0
7 S Exterior Concrete Block-Ext InsuMBathRm 5 9 0 8 0 72.0 ft2 0 0 0.3 0
8 S Exterior Concrete Block-Ext Insul Wic 5 7 8 8 0 61.3 ft2 0 0 0.3 0
3/11/2018 9:10 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5
1
FORM R405-2017
WALLS
Adjacent Cavity Width Height Sheathing Framing Solar Below 1
Space R-Values Eracfio A u
��p P R uan�P Et In Et In Area
9 W Garage Frame-Wood Wic 13 11 0 ` 8 0 88.0 ft2 0 0.25 0.01 0
10 W Garage Frame-Wood Utility 13 8 4 8 0 66.7 ft2 0 0.25 0.01 0
11 W Exterior Concrete Block-Ext Insul Foyer 5 6 0 8 0 48.0 ft2 0 0 0.3 0
-12 S Garage Frame-Wood Foyer 13 12 0 8 0 96.0 ft2 0 0.25 0.01 0
13 N Exterior Concrete Block-Ext InsulBedRm3 5 14 0 8 0 112.0 ft2 0 0 0.3 0 .
_14 N Exterior Concrete Block-Ext InsulBathRm 5 5 8 8 0 45.3 ft2 0 0 0.3 0
15 N Exterior -Concrete Block-Ext InsulBedRm2 5 12 8 8 0 101.3 ft2 0 0 0.3 0
16 S Exterior Concrete Block-Ext InsulBedRm2 5 9 4 8 0 74.7 ft2 0 0.3 0
17 W Exterior Concrete Block-Ext InsulBedRm2 5 14 8 8 0 117.3 ft2 0 0 0.3 0
_18 E Exterior Concrete Block-Ext InsuLivingRm 5 13 8 8 0 109.3 ft2 0 0 0.3 0
DOORS
# Ornt Door Type . Space Storms U Value Width Height Area
Ft In Ft In
1 W Insulated Foyer None .35 3 7 21 ft2
2 W Insulated Utility None .46 3 7 21 ft2
WINDOWS
Orientation shown is the entered,Proposed orientation.
/ Wall Overhang
V "' # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening
1 N 1 TIM Low-E Double Yes 0.65' 0.35, N 15.0 ft2 1 ft 0 in 1 ft 0 in Drapesiblinds Exterior 5
2 E 2 TIM Low-E Double Yes 0.65 0.35 N 9.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5
3 E 5 TIM Low-E Double Yes 0.65 '0.35 N 15.0 ft2 1 ft 0 in 1 ft 0 in Drapestblinds Exterior 5
4 N 13 TIM Low-E Double Yes 0.65 0.35 N 15.0 ft2 1 ft 0 in 1 ft 0 in Drapes/blinds Exterior 5
5 W 17 TIM Low-E Double Yes 0.65 0.35 N 15.0 ft2 1 ft 4 in 0 ft 6 in Drapes/blinds Exterior 5
i
6 E 18 TIM Low-E Double Yes 0.65 0.35 N 39.7 ft2 9 ft 4 in 0 ft 6 in Drapes/blinds Exterior 5
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 412.3089 ft2 412.3089 ft2 64 ft 8 ft 1
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000356 1534.4 84.24 158.42 .2669 7
3/11/2018 9:10 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 6
FORM R405-2017
HEATING SYSTEM.:
# System Type Subtype -Efficiency Capacity Block Ducts
1 Electric Heat Pump/ Split HSPF:8.5 28 kBtu/hr 1 sys#1
COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow;' SHR Block Ducts
1 Central Unit/ Split SEER:15 27.8 kBtu/hr 927 cfm 0.73 1 sys#1
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None .Garage 0.97 50 gal 60 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None ft?
DUCTS
—Supply— --Return Air CFM 25 CFM25 HVAC#
# Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 225 ft2 Attic 150 ftZ Default Leakage Garage (Default) (Default) 1 1
TEMPERATURES
Programable Thermostat:N Ceiling Fans:Cooling Jan Feb Mar Apr May [X] ri
Venting Jan Feb X Mar Apr Oct Nov Dec
May Jun [ ]Jul Aug X)Sep La Occt X Nov Dec
Jun [ 111 Jul Aug [ ]Sep LxJ
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) FM 80 80 80 80 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 80 80 78 78 78 78 78 78 78 78
Heating(WD) AM 65 65 65 65 65 65 65 68 68 68 68 68
PM 68 , 68 68 68 68 68 68 68 68 68 68 . 68
Heating(WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68
PM 68 68 .68 68 68 68 68 68 68 68 68 68
3/11/2018 9:10 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5
FORM R405-2017
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the EnergyPerformance Index,the more efficient the home.
5130 20th St, Zephyrhills, FL, 33542
1. New construction or existing New(From Plans) 9. Wall Types Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Ext Insul,Exterior R=5.0 1434.70 ft2
b.Frame-Wood,Adjacent R=13.0 250.67 ft2
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 3 d.NIA R= ft2
5. Is this a worst case? No 10.Ceiling Types Insulation Area
a.Under Attic(Vented) R=30.0 1644.00 ft
6. Conditioned floor area(ft2) 1644 b.N/A R= ft2
7. Windows- Description Area c.NIA R= ft2
2
a. U-Factor: Dbl,U=0.65 108.67 ft2 11.Ducts R ft
a.Sup:Attic,Ret:Attic,AH:Garage 6 225
SHGC: SHGC=0.35
b. U-Factor. N/A ft2
SHGC: 12.Cooling systems kBtu/hr Efficiency
c. U-Factor: N/A ft2 a.Central Unit 27.8 SEER:15.00
SHGC:
d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency
SHGC: a.Electric Heat Pump 28.0 HSPF:8.50
Area Weighted Average Overhang Depth: 4.088 ft.
Area Weighted Average SHGC: 0.350
8. Floor Types Insulation Area 14.Hot water systems
a.Slab-On-Grade Edge Insulation R=0.0 1644.00 ft2 a.Electric Cap:50 EF:0.97
b.N/A R= b. Conservation features
c.N/A R= ft W 2 None
15.Credits None
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed ;
based on installed Code compliant features.
Builder Signature: �JN �� Date:
'/ � c >
Address of New Home: 9/2 6. ZO fh S J City/FL Zip: ZcP/��y�,;(/J 3 54 �q•c�� �
r
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at
techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of
certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building
Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
3/11/2018 9:11 PM EnergyGauge®USA-FlaRes2017 -Section R405.4.1 Compliant Software Page 1 of 1
l
Manual S Compliance Report Job: R0318107
- wrightsoft- p P Date: 0310812018
Entire House By: MKC
Teri Butterfield
37516 Cook Ave,Dade City,FL
Project • •
For. Butterfield Investments,Inc.
5130 20th St,Zephyrhills,FL 33542
Cooling Equipment
Design Conditions
Outdoor design DB: 91.4°F Sensible gain: 20273 Btuh Entering coil DB: 79.1 OF
Outdoor design WB: - 77.2°F Latent gain: 3928 Btuh Entering coil WB: 64.4°F
Indoor design DB: 75.0°F Total gain: 24201 Btuh
Indoor RH: 50% Estimated airflow: 927 cfm
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: SplitASHP
Manufacturer. Goodman Mfg.or Eqv Model: GSZ14030+AVPTC37
Actual airflow: 927 cfm
Sensible capacity: , 20294 Btuh 100%of load
Latent capacity: 7506 Btuh 191%of load
Total capacity. 27800_ Btuh 115%of load SHR: 73%
Heating Equipment
Design Conditions
Outdoor design DB: 42.9°F Heat loss: 19555 Btuh Entering coil DB: 69.1°F
Indoor design DB: 70.0°F
Manufacturer's Performance Data at Actual Design Conditions
Equipmenttype: SplitASHP
Manufacturer. Goodman Mfg.or Eqv Model: GSZ14030+AVPTC37
Actual airflow: 927 cIrn
Output capacity: 28000 Btuh 143%of load Capacity balance: 35 OF
Supplemental heat required: 0 Btuh Economic balance: -99 OF
Backup equipment type: Elec strip
Manufacturer. Model:
Actual airflow. 927 c6n
Output capacity: 8.0 kW 140%of load Temp.rise: 27 OF
Meets all requirements ofACCA Manual S.
wrightsoft- 2018-Mar-0915 0223
Rigtt SUte@ Uriversal 201818.0.10 RSU20773 Page 1
ACCA ...aWorkHe1R0318107-5130 20thStR0318107.np Calc=MJ8 Frort Door faces:W
f
wrightsoW Project Summary Job: R0318107
Date, 0310812018
Entire House By: MKC
Teri Butterfield
37516 Cookke,Dade City,FL
Project Information
For. Butterfield Investments Inc,
5130 20th St,Zephyrhills, 33542
Notes: Load calculation was obtained from a digital copy of the CAD drawing.
Desicin Information
Weather. Tampa InflAR FL,US
Winter Design Conditions Summer Design Conditions
Outside db 43 OF Outside db 91 OF
Inside db 70 OF Inside db 75 OF
Design TD 27 OF Design TD 16 OF
Daily range L
Relative humidity 50 %
Moisture difference 54 grfib
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 16014 Btuh Structure 13397 Btuh
Ducts 3541 Btuh Ducts 5169 Btuh
Central vent(0 d1m) 0 Btuh Central vent(0 cfirn) 0 Btuh
(gone) (none)
Humidification 0 Btuh Blower 1707 Btuh
Piping 0 Btuh
Equipment load 19555 Btuh Use manufacturers data y
RatelsWqn It ' 1.00 1 Equ,pmenj mu p Jer
Infiltration sensible load 20273 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Average
Fireplaces 0 Structure 2406 Btuh
Ducts Btuh
Central vent(0 cfim) 1522 0 Btuh
He ti Coo (none)
Area(ftZ) IM - ft Equipment latent load 3928 Btuh
Molurne(fl?) 13152 13162
A r changesthour 0.38 — 0.20 Equipment Total Load(Sen+Lat) 24201 Btuh
Equiv.A\/F(cfirn) 83 44 Rdq-total capacity at 0.73 SHR 2.3 ton
Heating Equipment Summary I Cooling Equipment Summary
Make Goodman Mfg.or Eqv Make Goodman Mfg.or Eqv
Trade Split HP Trade Split HP
Model GSZ14030 Cond GSZ14030
AHRI ref 8996184 Coil AVPrTC37
- AHRI ref 8996184
Efficiency 8.5 HSPF Efficiency 12.5 EER 15 SEER
Heating input Sensible cooling 20294 Btuh
Heating output 28000 Btuh @ 47-F Latent cooling 7506, Btuh
Temperature rise 27 OF Total cooling 27800 Btuh
Actual airflow 927 cirri Actual airflow 927 ckn
Airflowfactor 0.047 dm/Btuh Airflowfactor 0.050 cfim/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.84
Capacity balance point=35 OF
Backup: Aux Heat
Input=8kW, Output=27297 Btuh,100 AFUE
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
-rk Pjgtt-Sdte@Udwrw1 2018 18.0.10 RSU20773 2018-Mar-09 15':02:23
Aft -513020thSW0318107np Ca1c=MJ8 FrortWorlaces;W Page I
aworkReR0318107
-i - wrightsoft' Right-JO Worksheet Job: R0318107
Entire House Date: 0310812018
By: MKC
Teri Butterfield
37516 Cook Ave,Dade City,FL
1 Room name Entire House Kitchen
2 vyp 179.3 it, 46.0 it
3 Room height 8.0 it 8.0 it heaV000l
4 Room dimensions 13.0 x 23.7 it
5 Room area 1644.0 it 307.7 IF
Ty I Construction U-value Or HTM Area (its Load Area (12) Load
number (BtuhfiF-°F) (B or pedMeLr (it) (Btuh) or perimeter (it) (Btuh)
Heat Cool Gross N/P/S Heat Cool Gross NOS Heat I Cool
6 VN 13A,5ocs 0.125 n 3.39 247 523 493 1669 1216 189 174 591 430
L-G 4A3-2ob 0.650 n 17.61 14.61 30 0 528 438 15 0 264 219
13A-5ocs 0.125 a 3.39 247 320 256 868 633 104 95 322 235
10D-b 0.650 a 17.61 1023 40 40 699 406 0 0 0 0
11 4A3.2ob 0.650 a 17.61 35.98 9 0 159 324 9 0 159 324
4A3-2ob 0.650 a 17.61 35.98 15 0 264 540 0 0 0 0
W 13A-5acs 0.125 s 3.39 247 427 4Z7 1445 1053 75 75 253 184
13A-5ocs 0.125 w 3.39 247 165 129 438 319 0 0 0 0
4A3-2ob 0.650 w 17.61 33.51 15 2 254 503 0 0 0 0
11N0 ' 0.350 w 9.48 10.83 21 21 199_ 227 0 0 0 0
q 12C-0sa 0.091 - 247 1.46 251 230 566 335 0 0 0 0
L.--D 11N0 0.350 n 9.48 10.83 21 21 199 227 0 0 0 0
C 16B-30ad 0.032 - 0.87 1.74 1644 1644 1426 2865 308 308 287 536
F 22A-cpl 0.989 - 26.80 0.00 1644 179 4806 0 308 46 1238 0
6 c)AED exu sion 0 -114
Envelope loss(gain 13532 9087 3088 1814
12 a) Infiltration 2482 791 637 203
b) Room ventilation 0 0 0 0
13 Internal gains Ocarpants @ 230 4 920 0 0
( AppllanoesMer 2600 1Z00
Subtotaloines6tn13) 16014 13397 3724 3217
Lesse#emalload 0 0 0 0
Lesstransfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 16014 13397 3724 3217
15 Ductloads 22% 39%j 3541 5169 229/6 390/0 824 1241
Total room bad 19555 18567 4548 4458
Air required(dm) 927 927 2161 223
Calculations approved bvACCA to meet all requirements of Manual J 8th Ed.
rN}F- wrigtitsoTt^ 2018-Mar-0915:0223
A - -- Right-Bute®Universal 201818.0.10 RSU20773 Pagel
aWorkFIeV20318107-5130 20thW0318107.np Catc=MJ8 Front Door faces:W
wrightsoft' RIg ht-JO Worksheet Job: R0318107
Date: 03/08/2018
Entire House By: MKC
Teri Butterfield
37616 CookAve,Dade City,FL
1 Room name MBedRm M3athRm
2 Roomed wall 8.0 ft 40.7 ft heaVODol 8.0 it 9.0 it
3 Room height 13.3 x 18.0 it13.3 x 9.0 it4 Room dimensions.
5 Room area 240.0 ft 120.0 ft2
Ty Construction U-value Or HTM Area (ftF) Load Area (T) Load
number (BtuhW- ) (BtuW or Perimeter (fl) (Btuh) or perimeter (it) tBiuh)
Heat Cod Gross N/P/S Heat Cod Grass NIPS Heat Cod
6 Vy 13A-5ocs 0.125 n 3.39 247 75 75 253 184 0 0 0 0
t-.G 4A3-2ob 0.650 n 17.61 14.61 0 0 0 0 . 0 0 0 0
13A-5ocs 0.125 a 3.39 247 107 92 311 226 0 0 0 0
10D-b 0.650 a 17.61 1023 0 0 0 0 0 0 0 0
11 4A3-2ob 0.650 a 17.61 35.98 0 0 0 0 0 0 0 0
4A3-2ob 0.650 a 17.61 35.98 15 0 264 540 0 0 0 0
W 13A-5ocs .0.125 s 3.39 247 .144 144 488 3% 72 72 -244 178
13A 5ocs 0.125 w 3.39 247 0 0 0 0 0 0 0 0
4A3-2ob 0.850 w 17.61 33.51 0 0 0 . 0 0 0 0 0
�-D 11NO 0.350 w 9.48 10.83 0 0 0 0 0 0 0 0
q 12C-09N '0.091 - 247 1.46 0 0 0 0 0 0 0 0
L-_-_D 11NQ 0.350 n 9.48 10.83 "0 0 ' ' 0 0 0 0 0 0
C 16B-30ad 0.032 - 0.87 1.74 240 240 208 418 120 120 104 209
F 0.989 - 26.80 0.00 240 41 .1090 -0 120 9 .- 241 0
6 c)AED excursion 84 -15
Envelope lossWn 2814 1808 589 372
12 a) Infiltration 563 179 125 40
b) Room oenfilation 0 0 0 0
13 Internal gains Oompants@ 230 2 460 0 0
il
Applianosslother 0 0
Subtotal(lines6to 13) 3176 2448 -714 412
Less eAemalfoad 0 0 0 0 :
Lesstrainsfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 3176 2448 714 412 .
15 Ductloads 22% 390/0 702 944 22% 39%1 158 159
Total room load 3879 3392 872 571
Air required(dm) 184 169 411 28
Calculations approved bvACCA to meet all requirements of Manual J 8th Ed.
- wrigletsoft- 2018-Mar-0915.,0223
Right-Srite�Uriversal201818.0.10 RSU20773 Page 2
aWorkFle1R0318107-5130 20thSfRO3l8107xW Calc=M.S FrortDoorfaces.W
- wrightso>ft• Right-JO Worksheet Job: R0318107
Entire House Date: 03/08/2018
By- MKC
Teri Butterfield
37516 Cook Ave,Dade City,FL
1 Room name Wic Utility
2 Exposed wall 7.7 ft 0 It
3 Room height 8.0 ft heat/000l 8.0 ft heat/cool
4 Room dimensions 11.0 x 7.7 ft 8.3 x 7.7 It
5 Room area 84.3 T 63.9 T
Ty Construction U-value Or HTM Area (W) Load Area (f* Load
number (Btuhr-F) or perimeter (it) (Btuh) or perimeter (ft) (Bluh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/s Heat Cool
6 yJ, 13A-5ocs 0.125 n 3.39 Z47 0 0 0 0 0 0 0 0
r G 4A3lob 0.650 n 17.61 14.61 0 0 0 0 0 0 --0 . 0
13A-5ocs 0.125 a 3.39 2.47 0 0 0 0 0 0 0 0
10D-b 0.650 a 17.61 10.23 0 0 0 0 0 0 0 0
11 4A3-2ob 0.650 a 17.61 35.98 0 0 0 0 0 0 0 0
4A3-2ob 0.650 a 17.61 35.98 0 . 0 0. 0 0 0 0 0
W 13A-5ocs, 0.125 S 3.39 Z47 61 61 208 151 0 0 0 0
� 13A-sacs 0.125 w 3.39 Z47 0 0 0 0 0 0 0 0
jL-G 4A3-2ob 0.650 w 17.61 33.61 0 0 0 0 0 0 0 0
L-D 11 No 0.350 w 9.48 10.83 0 0 0 0 0 0 0 0
R 12C-09N Q091 - Z47 1.46 68 88 217 129 67 46 113 67
I---D 11NO 0.350 n 9.48 10.83 0 0 0 0 21 21 199 227
C 16B-30ad 0.032 - 0.87 1.74 84 84 73 147 64 64 55 111
F 22A-W 0.989 - 26.80 0.00 84 8 205 0 64 0 0 0
i
6 'c)AED excursion -16 -31
Envelope losslgain 703 411 367 374
12 a) Infiltration 106 34 0 0
b) Room ventilation 0 0 0 0
13 Internal gains oar Opants @ 230 0 0 0 0
Applianoeslother 0 500
Subtotal(lines 6to13) 810 445 367 874
Lessexterrrat load 0 0 0 0
Lesstransfer 0 0 0 0
Recishibution 0 0 0 0
14 Subtotal 810 445 367 874
15 Dud loads 22% 390/0 179 172 221. 39% 81 337
Total room load 989 617 1 1 448 1212
Airrequired(dm) 47 31 21 61
Calculations approved byACCAto meet all requirements of Manual J 8th Ed.
�}� wrigfetsoYt.�A - RigFt Srite®Urinrersa1201818.0.10 RSU20773 2018-Mar-0915A2:23
Page 3
aWorkFIe1R0318107-5130 20fhSfR0318107np Calc=MJB FrortDoorfaces:W
wrightsoft• RIg ht-M Worksheet Job: R0318107
Date: 03/0812018
Entire House By: MKC
Teri Butterfield
37516 CookAve,Dade City,FL
1 Room name Foyer BedRm3
2 EVosedvdl 6.0 ft 14.0 ft
3 Room height 8.0 ft heat/000l 8.0 ft heat/cool
4 Room dimensions 6.0 x 19.7 ft 1.0 x 188.2 ft
5 Room area 118.0 ft 1882 ft
Ty Construclion U-value Or HTM Area (M Load Area Load
number (BtuhAF-°F) (BtuhAt� or perimeter (ft) (Btuh) or perimeter (ft) (Bluh)
Heat Cool Gross N/P/S Heat Cool Gross I NIP/S Heat Cool
6 VN 13ASocs 0.125 n 3.39 Z47 0 0 0 0 112 97 329 239
t-L' 4A32ob 0.650 n 17.61 14.61 ' 0 0 0 0 15 0 264 219
13A5ocs 0.125 a 3.39 Z47 0 0 0 0 0 0 0 0
10D-b 0.650 a 17.61 1023 0 0 0 0 0 0 0 0
11 4A3-2ob 0.650 a 17.61 35.98 0 0 0 0 0 0 0 0
4A3.2ob 0.650 a 17.61 35.98 0 0 0 0 0 0 0 0
W 13A-5ocs 0.125 s 3.39 247 0 0 0 0 0 0 0 0
13A-5ocs 0.125 w 3.39 Z47 48 27 91 67 0 0 0 0
4A3-2ob 0.650 w 17.61 33.51 0 0 0 0 0 0 0 0
11N0 0.350 w 9.48 10.83 21 21 199 227 0 0 0 0
R 12C-0sw 0.091 - 247 1.46 96 96 237 140 0 0 0 0
T-D 11NO 0.350 n 9A8 10.83 0 0 0 0 0 0 0 0
C 161350ad 0.032 - 0.87 1.74 118 118 102 206 188 188 163 328
F 2.2A-0 0.989 - 25.80 0.00 118 6 161 0 188 14 375 0
1
6 c)AED excursion -23 57
Envelope losslgain 791 617 1131 749
12 a) Infiltration 83 26 194 62
b) Room ventilation 0 0 0 0
13 InternalgainsJ Occupants@ 230 0 0 1 230
Applianceslother 0 0
Subtotai(lines 6to13) 874 644 1325 1041
Less exlemalload 0 0 0 0
Lesstransfer 0 0 0 0
Redisiribution 0 0 0 0
14 Subtotal 874 6" 1325 1041
15 Dudloads 22% 39%1 193 248 22% 39% 293 402
Total room load 1067 892 1 1618 1443
Airrequired(dm) 1 51 45 77 72
Calculations approved bvACCA to meet all requirements of Manual J 8th Ed.
-�+- cur➢gthtsolFt 2018-Mar-0915,0223
A Right-SuteOUnversal201818.0.10 RSU20773 Page 4
aWorkFle\R0318107-5130 20thSt)RO318107np Calc=MJB FrortDoorfaces:W
wrightsoft• Rig ht-M Worksheet Job: - R0318107
Date: 03/0812018
Entire House By: INKC
Teri Butterfield
37516 Cook Ave,Dade City,FL
1 Room name BathRm BedRm2
2 INMedviall 5.7 It 36.7 ft
3 Room height 6.0 ft heatl000l 8.0 ft heatl0D01
4 Room dimensions 1.0 x 68.2 ft 14.7 x 12.7 ft
5 Room area 682 fP 185.8 T
Ty Construction U-value Or HTM Area (ft) Load Area . (fib Load
number (BtuhAFL'r-) (Btuh" or perimeter 01) (Btuh) or perimeter (fty (Bhih)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat I Cod
6 13A 5ocs 0.125 'ri 3.39 2.47 45 45 154 112 101 101 343 250
YG 4A3-2ob 0.650 n 17.61 14.61 0 _ 0 0 0 0 0 0 0
13A5ocs 0.125 a 3.39 Z47 0 0 0 0 0 0 0 0
1OD-b 0.650 a 17.61 1023 0 0 0 0 0 0 0 0
11 4A3.2ob 0.650 a 17.61 35.98 0 0 0 0 0 0 0 0
4A3-2ob 0.650 a 17.61 35.98 0 0 0 0 0 0 0 0
W. ,' 13A 5ocs 0.125 s -3.39 - 2.47 0 . 0 0- 0 75 75 253, 164
13A 5ocs 0.125 w 3.39 Z47 0 0 0 0 117 102 347 253 L-G 4A3-2ob 0.650 w 17.61 33.51 0 0 0 0 15 2 264 503
11NO 0.350 w 9.48 10.83 0 0 0 0 0 0 0 0
R 12C-Osw 0.091 - 2.47 1.46 0 0 0 0 0 0 0 0
_I---D 11NO .0.350 - n 9.48 10.83 0 0 0 0 0 0 0 0
C 168-30ad Q032 - 0.87 1.74 68 68 59 119 166 186 161 324
F 22A-W 0.989 - 26.80 0.00 68 6 .152 0 186 37 983 0
J
6 c)AED excursion -9 229
En%elope loss/gain. 365 222 2351 1743
12 a) Infiltration 78 25 608 162
b) Room ventilation 0 0 0 0
13 Internal gains Occupants@ 230 0 . 0 1 230
Applianceslother 0 0
Subtotal(lines 6to 13) 443 247 2858 2134
Less extemalload 0 0 0 0
Less"nsfer 0 0 0 0
Redshibulion 0 0 0 0
14 Subtotal 443 247 2858 2134
15 Dud loads 22% 39% 98 95 229/6 39% 632 824
Total room load 541 M2 3491 2958
Airrequired(dm) 26 17 1 165 148
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
} wrigtitso7Ft- 2018-Mar-0915.0223
RigttSUL-@Uriverml201818.O.lORSU20773 Pages
...aWorkFIe'R0318107-5130 20thStRO318107np Calc=MJ8 FrontDoorfaces:W
wrightsoft, Right-M Worksheet Job: R0318107
Entire House Cale: 0310812018
By: MKC
Teri Butterfield
37516 CookAve,Dade City,FL
1 .Room name Hall UvingRm
2 F�osed wall 0 ft 13.7 ft
3 Room height 8.0 ft heatlmol 8.0 ft heat/cool
4 Room dimensions 4.0 x 8.0 ft 1.0 x 235.9 ft
5 Room area 32.0 fly 235.9 f?
Ty Consfrudion U-value Or HTM Area OF) Load Area (ft5 Load
number (Bhch/WF) or perimeter (IQ (Btuh) or perimelear (ft) (Stuh)
Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool
6 yJ 13A-5ocs 0.125 n 3.39 - 247 0 0 0 0 0 0 0 0
I-G 4A32ob 0.650 n 17.61 14.61 0 0 0 0 0 0 0 0
13A5ocs 0.125 a 3.39 247 0 0 0 0 109 70 236 172
10D-b 0.650 a 17.61 1023 0 0 0 0 40 40 699 406
11 4A3-2ob 0.650 a 17.61 $5.98 0 0 0 0 0 0 0 0
4A3-2ob 0.650 • e 17.61 35.98. " 0 0 0 0 0 0 _ 0 0
W 13A-5ocs 0.125 s 3.39 247 _ _ 0 0 0 0 _ 0-_ 0 0 0
T::213A-5ocs 0.125 w 3.39 247 0 0 0 0 0 0 0 0
4A3-2ob 0.650 w 17.61 33.51 0 0 0 0 0 0 0 0
11NO 0.350 w 9.48 10.83 0 0 0 0 0 0 0 0
R 12C-OSN 0.691 - 2.47 1.46 0 0 0 0 0 0 0 0
t----D 11NO 0.350 n 9AS 10.83 0 -0 0 0 0 .0 0 0
C 16830ad 0.032 - 0.87 1.74 32 32 28 56 236 236 205 411
F 22A-0 0.989 - 26.80 0.00 _32 0 0 0 236 14 366 0
l
8 0)AED excursion -2 -67
Envelope IosJgain 28 54 15w gm
12 a) Infiltration 0 0 189 60
b) Room ventilation 0 0 0 0
13 Internal gains Oaupa Ys @ 230 0 0 0 0
Applianceslotw 0 900
SubtolalQines6to13) _ 28 54 1695 1882
Lessexharrd toad 0 0 0 0
tesstransfer 0 0 0 0
Redistribution 0 0 0 0
14 Subtotal 28 54 1695 1882
15 Ductloads 22% 39% 6 21 22% 3VI.1 375 726
Total mom load 34 75 2070 2608
Airrequired(dm) 2 4 98 130
Calculations approved bvACCAto meet all requirements of Manual J 8th Ed.
_ - wrightsoTt- 2018-Maa0915:0223
- Rigtt-SUL�OUriversa1201818.0.10RSU20773 . Page6
aWorkFIe1R0318107-5130 2MSt1R0318107.nip Cafo=MJB FrortDoorfaces:W
Bailey Contracting-5130 20th St 2,219 sq ft
Column Es
SQ. FEET PRICE
MAIN OR LIVING: 2,219 $ 112.65
OTHER AREA UNDER ROOF: - $ 88.00
OTHER: - $ -
VALUATION $ 249,970.35
FEE SHEET $ 1,290.00
ADDRESS $ 30.00
DR17EWAYI $ 45.00
BUILDING: $ 1,390.80
ELECTRICAL: $ 290.25
PLUMBING: $ 193.50
MECHANICAL: $ 135.45
SUB-TOTAL $ 2,010.00
TOTAL $ 2,010.00
SEWER: n/a
WATER: n/a
IRRIGATION: $ -
TOTAL: $ -
WATER METER: $ 473.78
IRRIGATION METER $ -
FIRE DEPARTMENT FEES
PLANS TOTAL: n/a
INSPECTION TOTAL:
PERMIT TOTAL
TOTAL: $
PUBLIC SAFETY IMPACT FEES
POLICE
FIRE
5% $ -
TOTAL: $ -
SUB-TOTAL $ 2,483.78
PARK IMPACT FEES
SIF'S:
100.0% $ -
1.0% $ -
TOTAL: $ -
TIF'S:
99% $ -
1% $ -
TOTAL: . $ 2,483.78
5130 20th St 2,219 Sq Ft .
Column Es -
SQ. FEET ; PRICE
MAIN OR LIVING: 2,219 $ 112.65
OTHER AREA UNDER ROOF: - $ 88.00
OTHER: - $ -
VALUATION $ 249,970.35
FEE SHEET $ 1,290.00
ADDRESS $ 40.00
DRIVEWAY1 $ 40.00
BUILDING: $ 1,395.80
ELECTRICAL: $ 290.25
PLUMBING: $ 193.50
MECHANICAL: $ 135.45
SUB-TOTAL $ 2,015.00
TOTAL $ 2,015.00
SEWER: n/a
WATER: n/a
IRRIGATION: $ -
TOTAL: $
WATER METER: $ 473.78 n/a
IRRIGATION METER $ -
FIRE DEPARTMENT FEES
PLANS TOTAL: n/a
INSPECTION TOTAL:
PERMIT TOTAL
TOTAL: $ -
PUBLIC SAFETY IMPACT FEES
POLICE
FIRE
5% $ -
TOTAL: $
SUB-TOTAL $ 2,488.78
PARK IMPACT FEES
SIF'S:
100.0% $ -
1.0% $ -
TOTAL: $ -
TIF'S:
99% $ -
1% $ -
TOTAL: $ 21488.78
Sin le Famil Dwe111
Y g .
P lan Review Comments
1: F.F:E. shall-be:a minimum of 8".above.the road.elevation and an engineered site plan.
2.. Lots shall be graded.to comply with R401.3 of the F.B.C.
3.. :Compaction:test required_if2411 or more of fill dirt is.brought.in=at any one place...
4: :Tie in survey required before pouring concrete..
5.: Driveways:require a R;O.W. use permit:: All 4.sides of driveway thru the sidewalk shall have.
.expansion material:.
6. All setbacks shall be met.:.
7.: .All.property markers shall be uncovered and marked at time o f f rst inspection.
-8. :All A.D.A. requirements shall be met. .
9- No electric;plumbing,_mechanical;.or framing shall be covered without an.inspection.and
approval first. ..
M All Garages shall:com ly;with:section R302:6 of.the:F.B.C.:_(Fire Separation)..
11. Appliances=shall not be installed in-a location where subjectto.mechanical damage unless -
:protected by approved barriers. M303.4'o£the F.B:C
12.'Waterheaters shallcomply with section'P607.3 of the F.B.C.
13. Foundation su orts for.A/C-units.shall be raised at least 3'.' above.finished grade. M1308..1
pP . , .
14..Return air in all:bedroorris..F:B.C. .M..1620.4,
15::Sirioke detector are to be:installed iri accordarrce:with.R313:1 of the.F.B.C.
16. All glazing requirements-are..to be in accordance with R308.4-of the F.B.-C..
17..All means.of egress are to be in-a"cordance with R311.:of the F:B.G.. .:
18.:`.`Green gypsum board" shall not be used as.a backer-iri:showers or tubs. R702.4.2 F.B.C.
19. Combination-type AFCI breakers are required at all locations requiring.an AFCI.type breaker:
20. Carbon monoxide alarms Will-be required in.new construction that uses fossil-burningheating
:or appliances or an attached garage: They shall be,installed in accordance with.the F.B.C.-
2 1. A11 plumbing, mechanical,:and;electrical shall be separate from unit to unit: This includes all.
Underground lurnbin
p Sand electric.
22.'All 2011:N.E.C: Codes.will.be enforced:. .
23:Tamper=Resistant Receptacles in accordance with 406.11 of the 2011 N:E:C
24::In accordance:.with the Land.Development.Code, lots shall be sodded before final of least 10 . . .
feet:around the structure:
25. A copy of the energy cacls'shall be-with-permit at all tunes
26 Copy of final insulation report shall be.provided with.permit before.rnab
F.F.E.=Finished Floor.Elevation
F.B.C=Florida Building.Code 6th_Editon
R;O.W-Right-of Way.
A.D.A.-Americans with Disabilities Act : N.E.C.-National Electric:Code(2011). .
---------------------
I IIIII IIII IIIII IIIII IIIII IIIII II���IIIII IIII IIII IIII IIII Rcpt:1940079 Rec: 10.00
2018043785 DS: 0.00 IT: 0.00
03/15/2018 B. M. , �7Dpty C-1e�r-�
2
Permit No. Parcel ID No / .Z (a-?-1.0000-6 G /00-/ 000
NOTICE OF COMMENCEMENT
State of rk(r i d a County of /V u S C
THE UNDERSIGNED hereby gives notice that Improvement will be made to certain real property,and in accordance with Chapter 713,Florida Statutes,
the following information is provided in this Notice of Commencement: nCD
1. Description of Property: Parcel Identification No._ l- 2&-L/—0 00 d " 0 2 /Q G+ 40000 W c
Street Address: 513U �� S�r« f z�ph(4rhdhr AFL 3 3 5q2 Ln N
2. General Description of improvement 51/ q)e la t7yl e �O-/+'�C /'7 L kl C0r7J /Gl C--6 �N
Z
a+m
i 01
3. OrwJner Information or Lessee information if the Lessee contracted for the Improvement: �w U
31325 Ambe.-I Ci. fZd Qadc U/6 � :WD
Address _ City State 3 0
Interest in Property:
Name of Fee Simple Titleholder. M
(If different from Owner listed above) W��y
o,go
�� 2 / State ,i
4. ontractor. `0 e/ /.tea"It City N o
I^ 3
0 meCa // 12 V d 7e.,D )yr►�//�`/II /^G -°+
Address �8_y239 city State
ul3_ -7
Contractor's Telephone No.: En
5. Surety:
Name
Address City 'State
Amount of Bond: $ Telephone No.:
6. Lender.Altm N-
Name
Address City State
Lender's Telephone No.:
7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by
Section 713.13(1)(a)(7),Florida Statutes:
Name
Address City State
Telephone Number of Designated Person:
8. In addition to himself,the owner designates of
to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statutes.
Telephone Number of Person or Entity Designated by Owner.
9. Expiration date of Notice of Commencement(the expiration date may not be before the completion of construction and final payment to the
contractor,but will be one year from the date of recording unless a different date is specified):
WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT
ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE
RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT.
Under penalty of perjury,I dedere that I have read the foregoing notice of commencement and that the facts stated therein are true to the best
of my knowledge and belief.
STATE OF FLORIDA
COUNTY OF PASCO
Signature of Owner or Lessee,or Owner's Lessee's Authorized
Of ticerAYrector/Panner/Manager
Signatory's Title/Office
The foregoing instrument was admowla geiJ before me this-nday of �� ,20 by ldilgAO
as IG(~^�i4- (type of aulldrity,e.g.,officer,trustee,attorney in fad)for
RL,446k- ,e(d PLWLNh-P-dj (name of party on behalf of am instrument wasexecuted).
```ptttttttrgprP�sonalty Kno O [IR Produced Identification Notary Signatur
``` e / -
`��� �Q !Yr�TJ �gf Identification Produced Name(print)
_= 4 m G11 3666 }Q
C
��'�sTq rE Q�wAdY alb csinoticecommencement_pco53048
Legend
P.O.C. Point of Commencement ® Indicates Asphalt Pavement
P.C.P. Permanent Control Point
P.R.M. Permanent Reference Monument Indicates Concrete Pavement
P.O.B. Point of Beginning
P.O.L. Point on Line Conc. Concrete
F.I.R. Found Iron Rod Asph. Asphalt
TyT F.I.P. Found Iron Pipe Mas. Masonry
rY 6061 F.N.& D. Found Nail & Disc Fr. Frame
F.C.M. Found Concrete Monument W.F. Wire Fence
�R� Per Legal Description or Plat(Recorded) Wd.F. Wood Fence
C Calculated CLF Chain Link Fence
M Field Measured S.P. Screen Porch
B/D Proportioned Section Breakdown CP Carport
RAD. Radius OHL Overhead Utility Line
Ch.L. Chord Length U.P. Utility Pole
Ch.B. Chord Bearing P.B. Plat Book
S.I.R. Set 1/2" Iron Rod Capped with U/C Utility Cylender
SCALE: 1" = 30' Identification "PSM 6061" R/W Right of Way
S.N.& D. Set Nail & Disc Centerline
Stamped "PSM 6061"
A/C Air Conditioner
0' 30' 60'
I
---- --------------------------------
NW Corner of the SW 1/4 of
Section 12, Township 26 S, Range 21 E
Found Railroad Spike
I
i
\I
m
.l N. 89.53'45" E. - 15.00' B/D 3RD AVENUE
n - EAST - 15.00 (R)
3 P.O.C. NW Corner of the SW 1/4 of the SW 1/4 of
- Section 12, Township 26 S, Range 21 E
o No Monument found or set
n
o S. 00'37'08" E. - 463.79' 8/1) (M)
z I I SOUTH - 463.20' (R)
i
F.I.P. 3/4"
P.O.B. Unplatted Lot Na ID Cap �1 .
m I F.I.P. 3/4" CLF Corner
I_ �No ID Cap - 2.3' N. 0.4' W F-
IN EAST - 142.50' (R) -- N. 89°55'17'
CLF Ln
LO
CD CD
""ti�'•O;' iLn
Ln
ad
Subject Pa eel
I T
Vocont
1— Co ., Ln
cn o
;rr``41 I4 j r Z e O i3
WEST - 142.50' (R) -- S. 89° 4'46" - 14 .32' ( )
F.I.R. 3/8" F.I.R. 1/2.
No ID Cap No ID Ca
CLF Corner
Lot 5, Block 1 — Pinecrest Subdivision 0.4' W. o.z' s
P.B. 5, page 55 I —
I
SW Corner of the SW 1/4 of
Section 12, Township 26 S, Range 21 E
Found Railroad Spike
SOUTH AVENUE
31009 Pasco Road Phone: (352) 588-3680
Sohn fralshl -professional sur' veyor k Yapper San Antonio, Florida 33576 Email: psm6061@gmail:com
Professional License number LS 6061 BOUNDARY SURVEY
Not valid without the signature and the original raised seal Client: Butterfield Investments, Inc.
of a Florida licensed surveyor and mapper. Work order number: W18-0210
Date of Survey: 2/22/2018
Additions or deletions to this survey map or report by other than the Certified To: Butterfield Investments, Inc.
signing party prohibited without written consent of the signing party.
���V�V n��IC1�n H�p� 5 N0�COV���n�V��0��55 ONP� �► �Y NSu1C�I John Walsh, P.S.M.
PA GE SECTION 12 FAGF- 2 FOP- 51GNATUM— & SEAL
TOWNSHIP 26 S RANGE 21 E
OF 2 PASCO COUNTY, FLORIDA Florida Surveyor's Registration No. 6061
Jacqueline-Boges
From: Nichole Spence(City of Zephyrhills Support)<support@zephyrhillsfl.zendesk.com>
Sent: Thursday, May 10, 2018 1:36 PM
To: Jacqueline Boges -
Subject: [FATHOM] Re: 5130 20th st by#19551
##- Please type your reply above this line -##
Your request (#207855) has been solved. TO REOPEN THIS REQUEST, reply to this email or click the link below:
https://zephvrhillsfl.zendesk.com/hc/requests/207855
.......................................................................................................................................................................................................................................................................................................................................................................................
I Nichole Spence (City of Zephyrhills Support )
L- L May 10, 10:36 AM MST
Hello Jacqueline Boges,
The changes you requested have been completed. Meter install service order created.
I am marking this ticket as solved.
Best Regards,
Nichole I FATHOM Support
............................................................................ .......................................................................................................................................................................................................................................................................... ......................
Nichole Spence (City of Zephyrhills Support )
May 9, 4:33 PM MST
Account # 2990199 has been created, service order for meter install to follow once completed.
Best Regards,
Nichole I FATHOM Support
.......................................................................................................................................................................................................................................................................................................................................................................................
Jacqueline Boges
-J Apr 12, 5:1 1 AM MST
full service for 5130 20th st water, sewer and water meter. by#19551
This email is a service from City of Zephyrhills Support .
1
Jacqueline-Boges
From: Nichole Spence(City of Zephyrhills Support)<support@zephyrhillsfl.zendesk.com>
Sent: Wednesday, May 9, 2018 7:34 PM
To: Jacqueline Boges
Subject: [FATHOM] Re: 5130 20th st by#19551
##- Please type your reply above this line -##
Your request (#207855) has been updated. REPLY TO THIS EMAIL or click the link below:
https://zephyrhilisfl.zendesk.com/hc/requests/207855
.....................................................................................................................................................................................................................................................................................................................................................................................
Nichole Spence (City of Zephyrhills Support )
-- May 9, 4:33 PM MST
Account# 2990199 has been created, service order for meter install to follow once completed.
Best Regards,
Nichole I FATHOM Support
..................................................................................................................................................................................................................................................................................................................................................................................
I =
Jacqueline Boges
Apr 12, 5:1 1 AM MST
full service for 5130 20th st water, sewer and water meter. by#19551
This email is a service from City of Zephyrhills Support .
1
Jacqueline•Boges
From: Jacqueline Boges
Sent: Tuesday, July 24, 2018 12:05 PM
To: 'support@zephyrhillsfl.zendesk.com'
Cc: John Bostic; CJ Funnel[; Martha Simons
Subject: research
Attachments: meter.pdf
Jackie,
Here in the City of Zephyrhills need to find out about a water meter order. My order#is 207855 requested back on May
9, 2018.The owner still has not received their water meter for their project.
I was given an acct#2990199 see attached could someone find out what is going on with this order. Company should
not be calling building dept as indicating we are installing the meters.
Thank you
daekle Boges =-
813-780--0020 ext 3513
"A rule I have had for years is:to treat the Lord Jesus Christ as a personal friend. His is not a creed, a mere doctrine, but it is He
Himself we have." Dwight L. Moody
Florida has a very broad public records law. Electronic communications regarding most City
of Zephyrhills business are public records and available upon request. Your e-mail
communications may therefore be subject to public disclosure. If you received this message in
error, please do not read, 'forward, copy, etc. and delete immediately.
PASCO COUNTY
DEVELOPMENT SERVICES 1, C8731 Citizens Drive Date: 12/28/2018
COUNTY-FLQRIDA. New Port Richey, FL 34654
OP..EN SkM.VrBRAN-r Pint s. 727-847-2411
** NOT A PERMIT *�
Receipt#: 1819059
FEE DESCRIPTION ACCOUNT CODE UNITS INVOICE# FEE AMOUNT PAID RECEIPT# DATE
Impact Fee Residential Solid 24503100-329010 1.00 1414398 $0.68 $0.68 1819059 12/28/18
Waste Single Family
1226210100000000120.
TOTALS: $0.68 $0.68
Receipt# Paid By Check# CC Auth# Cashier ID Workstation Receipt Date Amt Paid
1819059 Cash 534 BCCCP15W 12/28/2018 $0.68
Total Payments: $0.68
Pavor Address Phone
BAILEY CONTRACTING 5023 SUMMERHILL DR
P#19541
ZHLLS
Comments:
1226210100000000120
While you will be paying your bill with Pasco County Development Services,the full amount of the credit card or a-check fees,NOT shown above,is collected by
First Billing payment services.
MyReports/reports//PASCOPROD/PASCO/ReceiptPOS V6.rpt 12/28/2018 Page 1 of 1