HomeMy WebLinkAbout18-19586 CITY OF ZEPHYRHILLS
5335-8TH STREET
(813)780-0020 19586
BUILDING PERMIT SINGLE FAMILY RESIDENTIAL
PERMIT INFORMATION _ LOCATION INFORMATION
Permit#:19586 Issued: 4/26/2018 Address: 6549 WAGON TRAIL ST
Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL.
Class of Work: 101-NEW CONST/SFR Township: Range:
Proposed Use: NOT APPLICABLE Lot(s) Block: Section:
Sq. Feet: Est. Value: Book: Page:
Cost: 266,079.30 Total Fees: 11,394.69 Subdivision: SILVERADO
Amount Paid: 11,394.69 Date Paid: 4/26/2018 Parcel Number: 05-26-21-0080-00600-0250
CONTRACTOR INFORMATION. OWNER INFORMATION
Name: D_R HORTON INC Name: DR HORTON INC
Addr: 12602 TELECOM DR Address: 12602 TELECOM DR
TAMPA, FL. 33637 TEMPLE TERRACE FL 33637-0935
Phone: Lic: Phone: 813-549-1968
Work Desc: CONSTRUCT SINGLE FAMILY HOME 2,362 SQ FT
APPLICATION FEES
BUILDING FEE 1,088.77 ELECTRICAL FEE 222.53 PLUMBING FEE 148.35
MECHANICAL FEE 103.85 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00
PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE-sfr/100% 4,828.00
SCHOOL IMPACT FEE-sfr/1% 48.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32
Inspections Re uire
FOOTER 2ND ROUGH PLUMB MIS MISC INSULATION CEILING
FOOTER BOND DUCTS INSULATED SEWER MISC.
ROUGH ELECTRIC LINTEL MISC MISC.
1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC.
DUCTS INSTALLED WATER MISC DRIVEWAY
PRE-SLAB SHEATHING MISC. MISC.
CONSTRUCTION POLE FRAME MISC. MISC.
REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553A0 (2)(c)the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES:
NOTICE: In addition to the requirements of this permit, there maybe additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing,consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance
with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
CONTRACTORS SIGNATURE PERMIT OFFI
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIOlf
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
i
INSTR#2018065721 OR BK97 11 PG2285 Page lfl
04/1912018 10:55 AM Rcpt:1950013.Rec:10.00 DS:0.00 IT:0.00
PauCa S.0'WeiC Ph.D.,Pasco CoyO!;y.,"6"Cerk&Comytroffer
,)o 0
Permit No. Parcel ID No OS 2-6 2 1 ow L (,D0
NOTICE OF COMMENCEMENT
State of ElnrtI4,ct- County of pa--g
THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and In accordance with Chapter 713,Florida Statutes,
the following Information is provided In this Notice of Comm Vincen-prit: % It)(?(Zilob
1. Description of Property: Parcel Identification No.U)A- S
Street Address: 5 -tT7-;l -ZQM Vrh J1 IS -/--/ T3 5-c I I
L/
2. General Description of Improvement 6-ekj -5;,L \2,� IAA i. i-eS;deei C't-
3. Owner Information or Lessee information If the Lessee contracted for the improvement.
R kk ran
r ma Q _Z7
Z-('o Q-2- e _e�_rn M `fir &36 —C--L
Address city State
Interest in Property: 2ee- -e-
Name of Fee Simple Titleholder:
(If different from Owner listed above)
Address
I 1(po city State
.4. Contract
tm,
Address City— State
Contractor's Telephone No.:
5- Surety: A)/-a
Name'
Address city State
Amount of Bond: Telephone No.:
6. Lender. A)
Name
Address city State
Lender's Telephone No.:
7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by
Section 713.13(1)(a)(7),Florl da Statutes:
Name
�9 60 0 2-TO�co IQ—
Address State
Telephone Number of Designated Person:
B. In addition to himself,the owner designates A of
to receive a copy of the Llenors Notice as provided in Section 713.13(1)(b),Florida Statutes.
Telephone Number of Person or Entity Designated by Owner.
9. Expiration date of Notice of Commencement(the expiration date may not be before the completion of construction and final payment to the
contractor,but will be one year from the date of recording unless a different date is specified):
WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT
ARE CONSIDERED IMPROPER PAYMENTS UNDER CMAPTeR713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE
RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT.
Under penalty of peoury,I declare that I have read the foregoing notice of commencement and that the facts stated therein are We to the best
of my knowledge and belief.
STATE OF FLORIDA -Y
COUNTY OF PASCO
SignaVr,of Owner or Lessee,or Owner's or Lessee's Authorized
r !rector/Partner/Manager
R-C,5f. - 7 N/,,)
Signatory's Tiftle/Office
The foregoing instrument was acknowledged. before me thiA ,
�—day of .21tyby 1 I e-c-,G 0
as ��(Z-�01V —(type of authority,e.g.,officer,trustee,attorney in fact)for
777-T. (name of pa on ehalf f whom,'n,t,7t was executed).
Personally Known ffBR Produced Identification El' Notary Signature
Type of Identification Produced Name(Print)
Notary Pubfic State of Florida
Michelle Moye,
�9 MYCOMMISSIOOGG057321
V FVIrSS 12J2112020
iR I
wpdata/bcs/noticeCOMmencement �_pc053`48
D R HORTON INC-6549 Wagon Trail St-2,362 sq ft
o umn ts
SQ. FEET PRICE
MAIN OR LIVING: 2,362 $ 112.65
OTHER AREA UNDER ROOF: -
OTHER: - $ -
VALUATION $ 266,079.30
FEE SHEET $ 989.00
ADDRESS $ 40.00
DRIVEWAY $ 40.00
BUILDING: $ 1,088.78
ELECTRICAL: $ 222.53
PLUMBING: $ 148.35
MECHANICAL: $ 103.85
SUB-TOTAL $ 1,563.50
TOTAL $ 1,563.50
SEWER: n/a
WATER: n/a
IRRIGATION: $ -
TOTAL: $ -
WATER METER: n/a
IRRIGATION METER $ -
FIRE DEPARTMENT FEES
PLANS TOTAL:
INSPECTION TOTAL:
PERMIT TOTAL
TOTAL: $ -
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
FIRE $ 273.00
5% $ 26.35
TOTAL: $ 553.35
SUS-TOTAL $ 2,116.85
PARK IMPACT FEES $ 769.56
SIF'S: $ 4,828.00
100.0% $ 4,828.00
1.0% $ 48.28
TOTAL: $ 4,876.28
T I F'S: $ 3,632.00
99% $ 3,595.68
1% $ 36.32
TOTAL: $ 11,394.69
`.. PASCO.COUN�``iC; FLORIDA
Permit No.
�QQ Date Permitted
Builder Name/Owner Name C0 Control#
County Parcel No. 05-4.-2/-Q 08O-Q06C0-O?-60 SubDiv:
Address/Location U `C'
Classification/Type of Use t
TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit:
Exempt [] Yes ❑ No How Determined
Impact Fee Amount 2.,01) Zone No. TAZ:
SCHOOL IMPACT FEE
Account (056) Single-Family Detached House Amount $ �
(057) Mobile Home
(058) Other Residential
123) Collection Fee
Exempt [�Yes ❑No How Determined
s
PARKS AND RECREATION FEE
Land Account Land Credit Land Total
i Recreation Account Recreation Credit -Recreation Total
Zone TOTAL AMOUNT $ 7L9 Sk
Exempt Fj,Yes ❑ No How Determined
} LIBRARY FEE
Land Account Land Credit Land Total
Facility Account Facility Credit. Facility Total
Exempt ❑ Yes [] No How Determined Total Amount
RESOURCE FEE ERU
TOTAL.AMOUNT
Prepared By Checked By
NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION
PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE
BEEN PAID AND
RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY
lAcknowledgement below does not imply acceptance of concurrence,but simply receipt of a copy of this form,placing
the building permit owner on notice of this assessment and the conditions of payment for same.
i
DATE RECEIVED BY
RECEIPT NO. DATE BY
PASCO COUNTY
DEVELOPMENT SERVICES
—P 3S... ' ,;..:: 8731 Citizens'Drive Date:7/1 012 0 1 8
COUNTY.;.:ELpRIDA New Port Richey,FL 34654
UeLN{tit;��ts,C✓uucuNr Penc:es. 727-847-2411
�': T.A.- -1 .: .............:......
.............. ................-.......... .. ........,....:.............
Receipt#: 1774493
FEE DESCRIPTION ACCOUNT CODE UNITS INVOICE# FEE AMOUNT PAID RECEIPT# DATE
Impact Fee Residential Solid 24603100-329010 31.60 1362327 $31.60 $31.60 1774493 7/10/18
Waste Single Family
TOTALS: $31.60 $31.60
Recelot# Paid By Check# CC Auth# Cashier ID Workstation Receipt Date Amt Paid
1774493 Check 767925 540 BCCCP06W 07/10/2018 $31.60
Total Payments: $31.60
Pavor Address Phone
D R Horton 1341 Horton Circle
Arlington TX 76011
Comments:
City of
/IZephyh111 lidstVp
e
9 o-_=ss:%54 Trail Stre
et
Parcel:05 26 21 0080 00600 0250
while you will be paying your bill with Pasco county Development services,the full amount of the credit card or a-check fees,NOT shown above,Is collected by
First Billing payment services.
,I
MyReports/reports//PASCOPROD/PASC0/ReceiptPOS_V6.rpt 7/10/2018 Page 1 of 1
O
1:1:0IIIUfl -
v
City of Zephyrhills
BUILDING PLAN REVIEW COMMENTS
Contractor/Homeowner:
�De 4, 0�-
Date Received:
Site:
Permit Type:
Approved w/no comments:❑ Approved w/the below comments: C Denied w/the below comments: ❑
This comment sheet shall be kept with the permit and/or plans.
Kalvin Swi�e —Plans Examiner Date Contractor and/or Homeowner
(Required when comments are present)
813-780-0020 City Of ZephyrhillS f ermlt Application Fax-813-760-0021
Building Department
Date Received f `r"p^ 7 o f�'t= a i� a >?.� *+ ►
Phone Contact for Permitting
Owner's Name r c� j•. ¢= Owner Phone Number<t
.�
Owner`s Address �v�E.Q .Te !e c' '" �'� TC n"�� ��� �.�Owner Phone Number
Fee Simple Titleholder Name 'C_ Owner Phone Number --
Fee Simple Titleholder Address
Jq q JOB ADDRESS ] {� rf (S S LOT# Z--S
.SUBDIVISION n i Ca PARCEL ID#
. (OBTAINED FROM PROPERTY TAX NOTICE)
,- '
WORK PROPOSED rNEW CONSTR R
ADD/ALT SIGN DEMOLISH
INSTALL. • REPAIR
PROPOSED USE F-9'' SFR COMM OTHER'
TYPE OF CONSTRUCTION . E� BLOCK 0 FRAME Q STEEL
DESCRIPTION OF WORK ��L� t 1G��f3i ��.5 �)Cje_:i Z 6-c-4- 54 c,,-
BUILDING SiZE SQ FOOTAGE ` HEIGHT '_
r-�Trvr-rr-'r-rrr�-w-rr-r-ra'•r^m1-n"t^[^'r'z"r���7�r"s'•�,�"�r"I"3_F"s'Te-eat-c^T�rr-s"tr"�i-s-'C-B'-a�Q�e�r
BUILDING $ VALUATION OF TOTAL CONSTRUCTION
� C,0
=ELECTRICAL �$. AMP SERVICE 0 PROGRESS ENERGY 0 . W.R.E.C.
.�o]PLUMBING $
MECHANICAL $ VALUATION OF MECHANICAL INSTALLATiON
QGAS ROOFING F1 SPECIALTY OTHER
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA DYES NO
-t•-8-0-D--F-i-1�-G-G•-i-1-1-i-F-Fi-i-t--C--F-4-i--C--"e-+'r•-t�i-e-F-i-t-,"•-i-,i-t-tom.-.�t�-r�-�i�-i-t-i-t-8-i-�v-.E�i-�i-.-1-44-11 1! 11 3 ice-1•-i-•�-
BUILDER :,�'�y COMPANY JJ� -� c1 ``A`ci' , 1,
SIGNATURE REGISTERED Y/ N FEE CURREN Y(N
Address , l� jG�.�i ,� , ' � it� �. License'#
.FLECTRiCiAN COMPANY. �c-jmc�a(',J-ar ?
SIGNATURE' REGISTERED Y( N REE CURREN
Address License# Q%� i i
PLUMBER COMPANY (/tea'"� ,r` ��6'c�lt �` �'' %r��.�
SIGNATURE
/ , REGISTERED Y( N FEE CURREN Y/`N
Address { /f ,s��,� t� lF r9� is.P, z Li rC�"`cense# C 0 F,'/-
MECHANICAL ,r� o COMPANY ��i
SIGNATURE i r� "��"��^ '^" —^-REGISTERED YtI/ N FEE CURREN Y('N
Address 2 , -_Y"X e, Cry Ifle License# I C&
OTHER , _ - 2 COMPANY 11/( �1 /::. 1)f' /-1 'f_/A� a• .
SIGNATURE �^- REGISTERED Y/ N FEE CURREN Y/N ,
Address License# y�
tiilillll" 11III1i11 ! lIIII111111ii ! llDitliitllliiitl_iIIililittittitll
RESIDENTIAL Attach(2)Plot Plans; (2)sets of Building Plans; (1)set of Energy Forms;R-O-W Permit for new construction,
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Sllt.Fence installed,
Sanitary Facilities&1 dumpster;Site Work•Permit for subdivisions/large projects
COMMERCIAL Attach (2)complete sets of Building Plans plus a Life Safety Page; (1)set of Energy Forms. R=O-W Permit for new construction.
Minimum ten (10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Slit Fence installed,
Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance
SIGN PERMIT Attach(2)sets of Engineered Plans.
"PROPERTY-SURVEY required for all NEW construction.
Direction
Directions: ,
Fill out application completely,
Owner�Contractor sign back of application,notarized
If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500)
** Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (copy of contract required)
Reroofs if shingles - Sewers Service Upgrades A/C Fences(Plot/Survey/Footage)
Driveways-Not over Counter if on public roadways.-needs ROW
. .
'
.
NOTICE [}F DEED RESTRICTIONS: The undersigned understands that this permit may besUbi- ` to "deed"' resthnt� C n�
which may be more nas�ioUvethan County regu|a�ons. Theunderaignedaasumee `responsibility for compliance with any
applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESP ]NSlBlL|T|ES. If owner has hired a c onbootoror
contractors to undertake work, they may be requiredtn be licensed
in accordance with state and local regul'�itinna. If-the
contractor is not-licensed an required by |aw, both the owner and contractor may be cited for e misdemeanor violation
under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the
intondad\murk, they are advised to contact the Pasco County
Building Inspection Divie|on--L(cenainQ Section at727-847- �
' 8009. Fudharmmre, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign
portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as th�
contractor,�that may bean indication that he |a not propedylicensed and is not enb1|edto permitting privileges.in Pasco
County.
TBA0SP0BTAT|ON IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation.|rnpemt Fe'es and Recourse Recovery Fees may apply tothe construction of new buiid|ngs, change of
use in existing buildings, or expansion of existing bui|dinga, as specified in Pasco County Ordinance number 89-07 and
00'07. as amended. The undersigned also.underatando, that such fees, as may be due, will be identified at the time of
permitting. It is further understood that Transportation impact Fees and Resource Recovery Feeo.muot be paid prior to
receiving a "nart�oaba of occupancy" or final power ro|ea�e. If the project does not involve e certificate of occupancy or
final power release, the fees must be paid prior to permit issuance; Furthermore, if Pasco-County Water/Sewer Impact
fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of Work is$2.500.bO or rnora. \
certify that i, the applicant, have been provided with a copy of the "FloridaConstruction- Lien Law—Homeowner's
`
Protection Guido" prepared by the Florida Department of Agriculture.and Consumer Affairs. If the applicant is someone
other than the "owner", I certify that I have obtained a copy of the above described document and promise in good faith to
deliver itto the^ovvner' prior tocommencement.
CONTRACTOR'S/OWNER'S AFFIDAVIT: | certify that all the information in this application is accurate and that all work
will be done in compliance with all applicable laws regulating construction, zoning and, land development. Application is
hereby made to obtain e permit to do,work and inata|lsdon as indicated. | certify that no work or installation has
commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating
construction, County and City codes; zoning regu(aUona, and- \and development regu)abnns \ntha 'udmd\otion. | also
nerUfvthat | unUo�tand that the regulations of'othe� governrnent agencies may apply to the intended work, and that it \s
|bUhvt identify �uchageno\�s |nu\Udebuta�eOotUnl�edk%
n]yreoponm ' o ' . .
- Department OfEnvironmental Protection-Cypress Bayheada. Wetland Areas and Environmentally Sensitive
Lands,Water/Wastewater Treatment.
- Southwest Florida VVo1er Management D\str\ut-We||s, Cypress. Bayhoadn, VVcd\and Areas. Altering
Watercourses. ' .
' Army Corps of Engineers-Seawalls, Docks, Navigable Waterways.
- Department of Health & Rehabilitative Sen/ioeo/Environnnenta! Health Un�-VVo\|s, Wastewater Treatment'.
Septic Tanks.
' _
- US-Environmental Protection Agency-Asbestos abatement.
- Federal Aviation Authorhy-Runways. .
| understand that the following restrictions apply to the use of fill:
- ^ Use of fill io not allowed in Flood Zone"VW" unless expressly pernnittod`
' If the fill material is to be used in Flood Zone '`A", it is understood that a drainage plan addressing a
-"compensating volume" will be submitted at time of permitting vvh|nh is prepared by s professional anginea'r
licensed by the State ofFlorida. .
' If the fill rnoteha\.ia to be used in Flood Zone ^N' in connection xvh a permitted building using o1enn vvGU �
construction, I certify that fill will be used only to fill the area within the stem wall.
' If Jill material is to be used in any area. \ certify that use of such Ni will not adversely affect adjacent
. properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots less than one /1\
acre which are elevated by fill, an engineered drainage plan iarequinad. _
If \ am the AGENT FOR THE OWNER. \ pnonn\ae in good faith to inform the owner of the permitting conditions Set forth in.'
this affidavit prior to commencing construction.. | understand that a separate permit may be.required for electrical work,'
p|urnbing, nigny, vve||s, poo|s, air conditioning' gaa.,or other installations not specifically included in the application. A `
permit issued shall be uono1fued to be a license to proceed with-thawork and not as authority Loviolate, cancel, a\ter, or
set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter
requiring aoonect�nof errors-in plans, construction nr violations of any codes. Every permit issued shaUbecome invalid
un|mao the work authorized by such permit is commenced within six months of permit iosuanne, or if work authorized by
thap8rnoitiasuspendedorabandonedfbra,Aehud'ofsix (G) nnonthsaftorthe time the Work incommenced. An extension
may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate
` justifiable cause for the extension, If work ceases for ninety (9b) consecutive days,the job is cQnsidered abandoned.
WARNING TO OWNER: YOUR FAILURE TO REC[]R0'A NOTICE OF COMMENCEMENTN YOUR.PAY\0��TWICE FOR l8&PR0VEKOENTSTO`fOUB PROPERTY. IF YOU INTEND TO OBTAIN
FlNANCjNG, CONSULT .
FLORIDAWITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT,*
' _ `F_ 117.03) .
OWNER OR AGENT CONTRACTORG e this Subscribed and sworn to(or affirmed) before me this Who is/are personally known to me or hms1hmm
identification,. , as identification. '
otary Public Notary
Public `
44
` «
="....s°m/. Commission
Name of N
' typed,printed or stamped _- of Notary typed,_ --_-_ stamped- `
00 P&,Qf
:NNotary
`
PLOT PLAN
DESCRIPTION:(AS FURNISHED)
LOT 25, BLOCK 6, SILVERADO RANCH SUBDIVISION PHASE 6, 8 & 9A
AS RECORDED IN PLAT BOOK 75, PAGE(S) 75-80, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA.
Curve Table
Curve Length Radius, Delta Chord Bearing Chord PT .
C1 32.60' 55.20' 33'50'23' S55'49'39'E 32.13'
C2 13.55' 25.00' 31.03'03" S5717'08'E 13.38'
C3 3.61' 185.00' 01'07'02" S42'19'05"E 3.61'
C4 12.B2' 25.00' 29'22'57" N66'26'38"W 12.6B'
C5 151.99' 155.00' 56'10'54' S2529'55"E 145.97'
C6 117.31' 155.00' 43'21'5D' S19-05.23-E 114.53'
C7 34.68' 155.00' 12'49'04' S4710-50"E 34.60' ,�n�, ��G♦ ��
� �
z \ °G2F\ 9'�c S
1" = 30'
°.,. O yj
GRAPHIC SCALE 107.27
0 15 30
10,
v�,GG °� �y /C? PC
oa
.0
lop
s q>
0j, o
\ 1 D8.0 /
\ / ?ems• /. � A,�c0
lb
'\ On
sw
PO \ 9i
f
NCO 24 Tzsz \\ '�F ^��/ C:)
c•O0 " tV
� A t U1,0��06„ , e rV to7.8 LOT ON LOT CAL 8,34810NSSQ. FT.
vJ w 66 47, LIVING AREA = 1,828 SQ. FT.
C
107.0 GARAGE = 430 SQ. FT.
ENTRY = 16 SQ. FT.
PRIV TRACT' 11 1 LANAI = 88 SQ. FT.
ATE IyETLAND `^' \ PATIO = 0 SQ. FT.
AREA OONSEVgnON 'VS " DRIVEWAY = 424 SO. FT.
,7 A/C PAD = 12 SQ. FT.
DSO IMPERVIOUS = 34% SQ. FT.
J 9�%_ = 2826 SQ. FT.
SOD = 5,522 SQ. FT.
OFF PREPARED FOR: �1J RIGHT CALCULATIONS
O
RIGHT OF WAY = 655 SQ. FT.
DRIVE APRON = 158 SO. FT.
D R"HQR711N`€ PUBLIC S/W = 246 SQ. FT.
ffv'Nica!!': idi6i'£3I SOD = 251 SQ. FT.
TOTALS
AREA = 9,003 SO. FT.
BUILDING SETBACKS DRIVEWAY = 582 SQ. FT.
FRONT: 20'
SIDEWALK = 274 SO. FT.
REAR: 15' SOD = 5,773 SQ. FT.
SIDE: 7.5'
SIDE STREET: 20'
LEGEND:
NOTES: — —_'— BUILDING SETBACK LINE PI POINT OF INTERSECTION
PC POINT OF CURVATURE
1. ELEVATIONS SHOWN ARE PER LOT GRADING — CENTERLINE PT POINT OF TANGENCY
PLANS PROVIDED BY THE CLIENT. — — — — RIGHT OF WAY UNE RP RADIUS POINT
2. ELEVATIONS ARE BASED ON NAVD 1988 %X PRC POINT OF REVERSE CURVATURE
DATUM. PROPOSED ELEVATION PCC POINT OF COMPOUND CURVATURE
TYP TYPICAL
PROPOSED DRAINAGE FLOW CS CONCRETE SLAB
THIS PLOT PLAN IS INTENDED FOR.PERMITTING PURPOSES 0 CONCRETE (P) PER PLAT
CALCULATED
ONLY. THIS IS NOT INTENDED FOR THE CONSTRUCTION OF THE PROPOSED HOUSE. REFER TO HOUSE PLAN AND PB PLAT BOOK
A/c AIR CONDITIONER
OPTION LIST FOR CONSTRUCTION. ALL BUILDING SET BACK S/W SIDEWALK SQ. PAGES
SO. FT. SQUARE FEET
LINES SHOWN HEREON IS PER DATA FURNISHED BY CLIENT F.E.M.A. FEDERAL EMERGENCY MANAGEMENT AGENCY
AND IS FOR INFORMATIONAL PURPOSES ONLY. F.I.R.M. FLOOD INSURANCE RATE MAP
NAVD NORTH AMERICAN VERTICAL DATUM
NATIONAL GETIC VERTICAL
THIS IS NOT A SURVEY �&UE DRAINAGE&UlIL1TY EASEMENT DATUM
THIS IS A PLOT PLAN ONLY PO PRIVATE UTILITY EASEM NGT(PUBLIC)EASEMENT
FLOOD NOT9i SURVEYOR NOTES:
I HAVE EXAMINED THE F.I.R.M. MAP NO. 12101CO2BBF, 1. THE SURVEYOR HAS NOT ABSTRACTED THE
DATED SEPTEMBER 26, 2014. AND FOUND THE SUBJECT PROPERTY LAND SHOWN HEREON FOR EASEMENTS, RIGHT
APPEARS TO UE IN ZONE"X', AREAS DETERMINED TO BE OUTSIDE THE OF WAY, RESTRICTIONS OF RECORD WHICH
0.2%ANNUAL CHANCE FLOODPLAIN. THE SURVEYOR MAKES NO MAY AFFECT THE TITLE OR USE OF THE LAND.
GUARANTEES AS TO THE ABOVE INFORMATION. PLEASE CONTACT THE
LOCAL F.E.M,A. AGENT FOR VERIFICATION. 2. NO UNDERGROUND IMPROVEMENTS HAVE BEEN
BEARING BASIS: LOCATED EXCEPT AS SHOWN.
A5hA
BEARINGS SHOWN HEREON ARE BASED ON THE NORTH LINE OF LOT 25 3. NOT VALID WITHOUT THE AUTHENTIC
BLOCK 6 BEING N51'09'22"E, PER PLAT. ELECTRONIC SIGNATURE AND THE AUTHENTIC
A M E.R I CA N ELECTRONIC SEAL OF A FLORIDA LICENSED
(FIELD DATE:) REVISED: SURVEYOR AND MAPPER.
SU RV EY I N G Dlgitallysigned byh—W
SCALE: 1" = 3D FEET ^y�.;:�".�„,� eoleman
` •e� : rJames W BolQ_ MAPPING
INC. ; e a-American Surveyin.g.&
Mapping,
APPROVED BY JB r "•
CERTIFICATION OF AUTHORIZATION NUMBER LB#6393 g
3191 MAGUIRE BOULEVARD, SUITE 200 �'�;;.""`m".•'a' email=jb_o_IemanPasmcorporate.co FOR
THE
JOB NO. 171013 LOT 25, BLK 6 ORLANDO, FLORIDA 32803 m,c=US RN
(407) 426-7979 Date:2017.11.16092839-05'-
DRAWN BY. DSB PLOT PLAN 11 13 17 KJW WWW.AMERICANSURVEYINGANDMAPPING.COM JAMES W. BOLEMAN PSM# 6485 DATE
D.R. Horton-6549 Wagon Trail St St-2362 sq ft
o umn Es
SQ. FEET PRICE
MAIN OR LIVING: 2,362 $ 112.65
OTHER AREA UNDER ROOF: - $ 88.00
OTHER: - $ -
VALUATION $ 266,079.30
FEE SHEET $ 989.00
ADDRESS $ 40.00
DRIVEWAYJ 40.00
BUILDING: $ 1,088.78
ELECTRICAL: $ 222.53
PLUMBING: $ 148.35
MECHANICAL: $ 103.85
SUB-TOTAL $ 1,563.50
TOTAL $ 1,563.50
SEWER: $ 2.01 .00
WATER: $ W.00
IRRIGATION: $ -
TOTAL: $ 2,Ck5l.00,
WATER METER:1 $ 47 8
IRRIGATION METER $ -
FIRE DEPARTMENT FEES
PLANS TOTAL: n/a
INSPECTION TOTAL:
PERMIT TOTAL
TOTAL: $ -
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
FIRE $ 273.00
5% $ 26.35
TOTAL: $ 653.35
SUB-TOTAL $ 5,241.63
PARK IMPACT FEES $ 769.56
SIF'S: $ 4,828.00
100.0% $ 4,828.00
1.0% $ 48.28
TOTAL: $ 4,876.28
T I F'S: $ 3,632.00
99% $ 3,595.68
1% $ 36.32
TOTAL: $ 14,519.47
Sing e Fami y Dwe ing
Plan Review Comments
L' F.F.E. shall'be a.minimum.of.8" above.the road elevation and an engineered.site plan.
2.- Lots shall be graded to.comply with R401.3 of the F.B:.C:
3. Compaction:test required.if 24" or more of fill dirt is.brought in at any one place.
4. Tie in survey required before pouring concrete.
5. Driveways require a R.O.W. use permit: A11.4.sides of driveway thru the sidewalk shall'have.
expansion material:
6.. All setbacks shall be met.
-7.. All.property:markers shall be.uncovered and marked at time of first inspection.
.8.. All A.D.A. requirements shall be met.
9. No electric;plumbing, mechanical, or framing shall be.covered without an inspection and
approval first. .
10. All Garages shall comply-with section R302.6:of the.F.B.C. (Fire S:eparation).
11. Appliances shall'not be installed in.A location where subject to mechanical damage unless
protected by approved barriers. M303.4 o£.the F.B.0
12. Water heaters shall comply with section.P607.3 of the F.B.C.
13. Foundation supports for A/C units shall be raised at least 3" above finished grade.- M1308.1.
14. Return air in all bedrooms. F.B.C. M1620.4
15. Smoke detectors are.to be installed:in accordance:with R313:1 of the F.B.C.
-
16.: All glazing requirements are to be in accordance with R308.4.of the F.B.C.
17. All means.of egress are to:be in:accordance with,R311 of the F.B.C.
18. `.`Green gypsum board" shall not be'used.as a backer.in showers or tubs. R702.4.2.F.B.C.
19. Combination-type AFCI breakers are required:at all.locations requiring an AFCI.type breaker: . : .
20' Carbon monoxide alarms will be required in now construction-that uses fossil-burningieatin' -
or appliances or ari attached garage:. They shall be-installed in accordance with the F.H.C.-
2 1. All plumbing,mechanical, and electrical shall be separate from unit fo:unit: This includes all .
underground plumbing and electric:
22. All 2008 N.E.C: Codes will be enforced:
23.Tamper= Resistant Receptacles in..accordance with 406.11 of the 2008 N.E:C
24: In accordance:with the Land.Development:Code, lots shall be-sodded before final of least 10.
feet around the structure: _
25 A copy of the energy eacls shall be with perynit at all times.
26 Copy of final insulation report shall be.provided with:permit beforeliinaL
F.F.E.-Finished Floor Elevation
F.B.0'Florida Building,Code 5h.Edition
R.O.W.-Right of Way
A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2008) -
05-26-21-0080-00600-0250 Pasco County Property Appraiser Page 1 of 1
Data Current as Of: Weekly Archive - Monday, April 16, 2018
Parcel ID 05-26-21-0080-00600-0250 (Card: 001 of 001)
Classification 00 - Vacant Residential
Mailing Address Property Value
DR HORTON INC Ag Land $0
12602 TELECOM DR Land $2,987
TEMPLE TERRACE FL 33637-0935 Building $0
Physical Address Extra Features $0
6549 WAGON TRAIL STREET
ZEPHYRHILLS, FL 33541
Just Value $2,987
Legal Description (First 4 Lines) Assessed (Non-School Amendment 1) $2,987
See Plat for this
Subdivision Taxable Value $2,987
SILVERADO RANCH SUBDIVISION
PHASES 6, 8 &9A PB 75 PG 075
BLOCK 6
LOT 25
Jurisdiction
City of Zephyrhills
_ Land Detail (Card: 001 of 001) _
Line _ Use�Descript nog Zoning Units Type _ �Price__�_Condition V ueal _
1 _0100 SFR MPUD 6,000.00 _ SF $0.40 1.00 -� $2,400_
2 �I 0100 SFR _F_ MPUD �2,349.00 SF , $0.25 1.00 I $587
_ Additional Land Information
Acres 0.19 Tax Area�30SI Code -- Residential Code f SLVRCPI
Building Information - Use 00 - Unimproved (Card: 001 of 001)
Unimproved Parcel 00 - Unimproved
_ __ Extra Features (Card: 001 of 001)
Line _ Description Near Lnits Value _
No Extra Features
Sales History - See All 6 sales
Previous Owner: DUNE FL LAND I SUB LLC
Month/Year Book/Page (Type _ ;DOR Code Condition An mount
04/2018 19708 / 1472 Warranty Deed I 05 Vacant Multi-Parcel Sale
_ 05/2017 19535 / 0546 Certificate of Title_ 05 ---Vacant 'Multi-Parcel Sale
11/2016 9462 / 0384 Mineral Rights or Royalty Transfer, 05 I Vacant Multi-Parcel Sale
http://search.pascopa.com/parcel.aspx?parcel=2126050080006000250 4/19/2018
FORM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Cali 1828 Elev D ff Builder Name: DRH Ex ess Homes
Street: 4. ` Permit Office:
City,State,Zip: ZephyZliills, FL, S�ly Permit Number:
Owner: �l(2 Jurisdiction: 151
Design Location: FL,Tampa v' County:: Pasco(Flonda Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(1710.2 sqft.) Insulation Area
2. Single family or multiple family Single-family, a.Concrete Block-Int Insul,Exterior R=4.1 1404.00 ft2
b. Frame-Wood,Adjacent R=11.0 306.22 ft2
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 4 d.N/A R= ft2
5. Is this a worst case? No 10.Ceiling Types (1828.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1828.00 ft2
6. Conditioned floor area above grade(ft2) 1828 b.N/A R= ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ft2
11.Ducts R ft2
7. Windows(166.5 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 356
a. U-Factor: Dbl,U=0.34 126.50 ft2
SHGC: SHGC=0.31
b. U-Factor: Dbl,U=0.55 40.00 ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: - SHGC=0.34 a.Central Unit 28.6 SEER:14.00
c. U-Factor: N/A ft2
SHGC: 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a.Electric Heat Pump 28.6 HSPF:8.20
SHGC:
Area Weighted Average.Overhang Depth: 2.722 ft.
Area Weighted Average SHGC: 0.317 14.Hot water systems
8. Floor Types (1828.0 sqft.) Insulation Area a.Electric Cap:50 gallonsEF:0.950
a.Slab-On-Grade Edge Insulation R=0.0 1828.00 ft2 b. Conservation features
b.N/A R= ft2 None
c.N/A R= ft2 15.Credits Pstat
Glass/Floor Area: 0.091 Total Proposed Modified Loads: 61.11 PASS
Total Baseline Loads: 61.25
I hereby certify that the plans and specifications covered by Review of the plans and ATE STq�,
this calculation are in compliance with the Florida Energy specifications covered by this
O _ - O.t•
Code. calculation indicates compliance
with the Florida Energy Code. rrrr° ��•: ;•°��ti,�O
PREPARED BY: L'Nti Before construction is completed
DATE: this building will be inspected for
compliance with Section 553.908 * °
I hereby certify that this building,as designed,is in compliance Florida Statutes.
with the Florida Energy
OWNER/AGENT: BUILDING O IC AL:
DATE: DATE: 001
- Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.2.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
test report in accordance with R402.4.1.2.
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with Section 803 of RESNET Standards, is not greater than 0.060 Qn for whole house.
11/11/2017 1:06 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4
' . . . .
FORM R4O5-2U14�
.
FLORIDA ������n��� ���U��8����� ������� ���� BUILDING CONSTRUCTION
~ .~—.. ..~_. . ~�~ ----ENERGY EFFICIENCY'---�_' --~ ' ~- ----__ FOR- __.~'_---- ~`_ .
FlOrida Department of BUGiOeSS and P[Of8SSiOOQl Regulation - Residential Performance Method
. .
Project Name: Cali 1828 Elev D Builder Name: D RH Express Homes
Street: b,)aQtn,7Fq'(( S4. Permit Office:
City,State,Zip: ZephyMills,FL, Per it Number:
Owner: Jurisdiction:
Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2
I. New construction.or existing New(From Plans) 9. Wall Types(1710.2 sqft.) Insulation Area
2. Single family or multiple family Single-family- a.Concrete Block-Int Insul,Exterior R=4.1 1404.00 W
3. Number of units,if multiple family 1 b.Frame-Wood,Adjacent R=1 1.0 306.22 ft2
5. Is this a worst case'? No 10.Ceiling Types (1828.0 sqft.) Insulation Area
a.Under Attic(Vented) R=30.0 1828.00 ft2
6. Conditioned floor area above grade(W) 1828 b.N/A R= ft2
Conditioned floor area below grade(W) 0 c.N/A R= ft2
7. Windows(166.5 sqft.) Description Area a.Sup:Attic, Ret:Main,AH:Main 6 356
Area Weighted Average Overhang Depth: 2.722 ft.
Area Weighted Average SHGC: 0.317 14.Hot water systems
8. FloorTypes (1828.0 sqft.) Insulation Area a.Electric Cap:50 gallons
a.Slab-On-Grade Edge Insulation R=0.0 1828.00 ft2 b. Conservation features EF:0.950
Glass/Floor Area: 0.091 Total Proposed Modified Loads: 61.11 PASS
Total Baseline Loads: 61.25
I hereby certify that the plans and specifications covered by Review of the plans and
this calculation are in compliance with the Florida Energy specifications covered by this 0
Code. calculation indicates compliance
with the Florida Energy Code.
PREPARED BY: Before construction is completed -1
DATE: this building will be inspected for
compliance with Section 553.908
I hereby certify'that this building,as designed,is in compliance Florida Statutes.
with the Florida Energy Co WIE
OWNER/AGENT:— BUILDING OFFICIAL:
' Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies oo
certified factory-sealed in accordance with R403.2.n.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
test report in accordance with R4V2.4.1.2.
' Compliance with a proposed duct leakage On requires a Duct Leakage Test Report confirming duct leakage 1ooutdoors,
tested in accordance with Section 803 of RESNET Standards,is not greater than 0.060 On for whole house.
11/11/20171x06Pm EnewrGauga@ USA'RaR000u1*Section n4no.4.1 Compliant Software Page of
'
;FORM R405-2014
PROJECT
Title: Cali 1828 Elev D Bedrooms: 4 __ Address Type: Lot Information
Building Type: User Conditioned Area: 1828 Lot# 25/6
Owner: Total Stories: 1 Block/SubDivision: Silverado Ranch
#of Units: 1 Worst Case: No PlatBook:
Builder Name: DRH Express Homes Rotate Angle: 45 Street:
Permit Office: Cross Ventilation: County: Pasco
Jurisdiction: Whole House Fan: City,State,Zip: Zephyrhills,
Family Type: Single-family FL,
New/Existing: New(From Plans)
Comment: Garage L Face NE
CLIMATE
/ IECC Design Temp Int Design Temp Heating Design Daily Temp
v Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,Tampa FL_TAMPA_INTERNATI 2 39 91 70 75 645.5 54 Medium
BLOCKS
Number Name Area Volume
1 Blockl 1828 15848.8
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
1 Main 1828 15848.8 Yes 5 4 1 Yes Yes Yes
FLOORS
# Floor Type Space Perimeter R-Value Area Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio Main 198.6 ft 0 1828 ftz __-- 0 0.25 0.75
ROOF
Roof Gable Roof. Solar SA Emitt Emitt Deck Pitch
v # Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
1 Hip Composition shingles 2044 ftz 0 ftz Dark 0.92 No 0.9 No 0 26.6
ATTIC
V # Type Ventilation Vent Ratio(1 in) Area FIBS IRCC
1 Full attic Vented 300 1828 ftz Y N
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Vented) Main 30 Blown 1828 ftz 0.11 Wood
1 1/1 1/2017 1:06 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 4
FORM R405=2014
WALLS
Adjacent Ca
Space vity Width Height Sheathing Framing Solar Belo w# Omt In Wall IV PP
1 N=>NE Exterior Concrete Block-Int Insul Main 4.0999 19 8 8 164.7 ft2 0 0.6 0
2 E=>SE Exterior Concrete Block-Int Insul Main 4.0999 43 8 8 8 378.4 ft2 0 0.6 0
3 S=>SW Exterior Concrete Block-Int Insul Main 4.0999 39 8 8 8 343.8 ft2 0 0.6 0
4 W=>NW Exterior Concrete Block-Int Insul Main 4.0999 59 8 8 8 517.1 ft2 0 0.6 0
5 N=>NE Garage Frame-Wood Main 11 20 0 8 8 173.3 ft2 0.23 0.01 0
6 E=>SE Garage Frame-Wood Main 11 15 4 8 8 132.9 ft2 0.23 0.01 0
DOORS
# Ornt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 N=>NE Insulated Main None .4 3 6 8 20 ft2
2 N=>NE Wood Main None .46 2 8 6 8 17.8 ft2
WINDOWS
Orientation shown is the entered orientation => changed to As Built rotated 45 degrees).
Wall Overhang
V # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening
1 N=>NE 1 Vinyl Low-E Double Yes 0.34 0.31 31.0 ft2 1 ft 0 in 4 ft 1 in Drapes/blinds Exterior 5
2 N=>NE 1 Vinyl Low-E Double Yes 0.34 0.31 2.5 ft2 3 ft 8 in 0 ft 0 in Drapes/blinds Exterior 5
3 E=>SE 2 Vinyl Low-E Double Yes 0.34 0.31 15.5 ft2 1 ft 0 in 0 ft 9 in Drapes/blinds Exterior 5
4 S=>SW 3 Vinyl Low-E Double Yes 0.34 0.31 62.0 ft2 1 ft 0 in 0 ft 9 in Drapes/blinds Exterior 5
5 S=>SW 3 Metal Low-E Double Yes 0.55 0.34 40.0 ft2 8 ft 0 in 0 ft 8 in Drapes/blinds Exterior 5
6 W=>NW 4 Vinyl Low-E Double Yes 0.34 0.31 15.5 ft2 1 ft 0 in 0 ft 9 in Drapes/blinds Exterior 5
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 430.0128 ft2 430.0128 ft2 46.6 ft 8.67 ft 0
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000386 1849 101.51 190.9 .2892 7
HEATING SYSTEM
# System Type Subtype Efficiency Capacity Block Ducts
1 Electric Heat Pump None HSPF:8.2 28.6 kBtu/hr 1 sys#1
11/11/2017 1:06 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 4
.FORM R405=2014
COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow SHR Black Ducts
1 Central Unit None SEER:14 28.6 kBtu/hr 858 cfm 0.75 1 sys#1
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.95 50 gal 70 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None ftz
DUCTS
----Supply---- ----Return---- Air CFM 25 CFM25 HVAC#
# Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 356 ftz Main 40 ftz Proposed Qn Main ---cfm 109.7 cfm 0.06 0.60 1 1
TEMPERATURES
Programable Thermostat:Y Ceiling Fans:
Coolin Jan Feb Mar A r Ma Jun Jul AugSe Oct r Nov Dec
Heating Jan H
Feb Mar APr l May l Jun l Jul f Aul SeP Oct [X]Nov Dec
Ventin Jan Feb Mar Apr [ May [ Jun l Jul l Aug l Se lxJ Oct [[[XXX]]]Nov Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78 .
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
11/11/2017 1:06 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 4
L
FORM R405-2014
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD,
ESTIMATEDENERGY PERFORMANCE INDEX* = 100
The lower the EnergyPerformance Index,the more efficient the home.
Zephyrhills, FL,
1. New construction or existing New(From Plans) 9. Wall Types Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul, Exterior R=4.1 1404.00 ftZ
b. Frame-Wood,Adjacent R=11.0 306.22 ft
3. Number of units,if multiple family 1 c.N/A R= ftz
4. Number of Bedrooms 4 d.N/A R= ftz
10.Ceiling Types Insulation Area
5. Is this a worst case? No a.Under Attic(Vented) R=30.0 1828.00 ftz
6. Conditioned floor area(ftz) 1828 b.N/A R= ftz
7. Windows- Description Area c.N/A R= ft2
a. U-Factor: Dbl,U=0.34 126.50 ftz 11. Ducts R ft
a.Sup:Attic,Ret:Main,AH:Main 6 356
SHGC: SHGC=0.31
b. U-Factor: Dbl, U=0.55 40.00 ftz
SHGC: SHGC=0.34 12.Cooling systems kBtu/hr Efficiency
c. U-Factor: N/A ftz a.Central Unit 28.6 SEER:14.00
SHGC:
d. U-Factor: N/A ftz 13.Heating systems kBtu/hr Efficiency
SHGC: a.Electric Heat Pump 28.6 HSPF:8.20
Area Weighted Average Overhang Depth: 2.722 ft.
Area Weighted Average SHGC: 0.317
8. Floor Types - Insulation Area 14. Hot water systems
a.Electric Cap:50 gallons
a.Slab-On-Grade Edge Insulation R=0.0 1828.00 ftz EF:0.95
b.N/A R= ftz
c.N/A R= ftz b. Conservation features
None
15.Credits Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building EST
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code com I+ atures04
.
Builder Signature: Date: I u-f 3'
Address of New Home: CD��q�J� '�!�Il j"I� City/FL Zip: �� �c,'�i~
33 WE
`Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
"'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
11/11/2017 1:06 PM EnergyGauge@ USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1
FORM R405-2014
Florida Department of Business and Professional Regulations
Residential Whole Building Performance and Prescriptive Methods
ADDRESS: Permit Number:
Zephyrhills,FL,
MANDATORY REQUIREMENTS See individual code sections for full details.
401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL)
display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law
[Section 553.9085,Florida Statues]requires the EPL display card to be included as an addendum to each sales contract for both presold and
nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components
installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans
and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix C.
R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of
Sections R402.1 through R402.4.4.
O R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.The
sealing methods between dissimilar materials shall allow for differential expansion and contraction.
• R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in
accordance with the manufacturer's instructions and the criteria listed in Table 402.4.1.1,as applicable to the method of construction.
Where required by the code official,an approved third party shall inspect all components and verify compliance.
• R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air
changes per hour in Climate Zones 1 and 2,and 3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with
a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an
approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code
official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
During testing:
1. Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or
other infiltration control measures;
2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended
infiltration control measures;
3.Interior doors,if installed at the time of the test,shall be open;
4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed;
5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and
6.Supply and return registers,if installed at the time of the test,shall be fully open.
O R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers and outdoor combustion air.
O R402.4.3 Fenestration air leakage.Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm
per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400 or
AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer.
Exception: Site-built windows,skylights and doors.
O R402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage
between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not
more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential.All recessed
luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering.
R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system.
R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls
that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load.
❑ R403.2.2 Sealing(Mandatory)AII ducts,air handlers,and filter boxes and building cavities that form the primary air containment
passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance
with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post-construction
or rough-in testing below.
Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either an energy rater certified in accordance with Section
553.99, Florida Statutes,or as authorized by Florida Statutes,to be"substantially leak free"by either of the following:
1. Post-construction test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area
when tested at a pressure differential of 0.1 inches w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure.All
register boots shall be taped or otherwise sealed during the test.
2. Rough-in test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested
at a pressure differential of 0.1 inches w.g.(25Pa)across the system,including the manufacturer's air handler enclosure.All registers shall be
taped or otherwise sealed during the test.If the air handler is not installed at the time of the test,total leakage shall be less than or equal to 3 cfm
(85 Umin)per 100 square feet(9.29 m2)of conditioned floor area.
Exceptions:
1. The total leakage test is not required for ducts and air handlers located entirely within the building envelope.
2. Duct testing is not mandatory for buildings complying by Section R405 of this code.
11/11/2017 1:06 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Com Page 1 of 3
FORNIr R405-2014
MANDATORY REQUIREMENTS - (Continued)
❑ R403.2.3 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums.
❑ R403.3 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C)
or below 55°F(13°C)shall be insulated to a minimum of R-3.,
R403.3.1 Protection of piping insulation.
❑ R403.4.1 Circulating hot water systems(Mandatory). Circulating hot water systems shall be provided with an automatic or readily
accessible manual switch that can turn off the hot-water circulating pump when the system is not in use.
❑ R403.4.3 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have
heat traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a
downward and upward bend of at least 3 1/2 inches(89 mm)in the hot water distribution line and cold water line located as close as possible
to the storage tank.
❑ R403.4.4 Water heater efficiencies(Mandatory).
0 R403.4.4.1 Storage water heater temperature controls
• R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls
capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum
temperature setting range shall be from 100°F to 140°F(38°C to 60oC).
• R403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied
to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s)
of combustion types of service water heating systems to be turned off.
0 R403.4.4.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of
Table C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation,Commercial Provisions,for the type of equipment installed.
Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water
heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1.
R403.4.4.2.1 Solar water heating systems. Solar systems for domestic hot water production are rated by the annual solar energy
factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of
Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors,
and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol,Collectors in installed solar water
heating systems should meet the following criteria:
1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and
2. Be installed at an orientation within 45 degrees of true south.
❑ R403.5 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the
Florida Building Code, Residential or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation.
Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating.
❑ R403.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment.
0 R403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the
equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies,
based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and
indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions
described in Section R302.1.This code does not allow designer safety factors,provisions for future expansion or other factors
which affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation
such as standard kitchen and bathroom exhaust systems.
• R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the
calculated total load,but not more than 1.15 times greater than the total load calculated according to the procedure selected in
Section 403.6,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the
equipment shall not be less than the calculated latent load.
1 1/1 1/2017 1:06 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Com Page 2 of 3
FORM R405-2014
MANDATORY REQUIREMENTS - (Continued)
O R403.6.1.1 Cooling equipment capacity.(continued) The published value for AHRI total capacity is a nominal,rating-test value and
shall not be used for equipment sizing.Manufacture's expanded performance data shall be used to select cooling-only equipment.This
selection shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry bulb temperature for the
load calculation(or entering water temperature for water-source equipment),the blower cfm provided by the expanded performance data,
the design value for entering wet bulb temperature and the design value for entering dry bulb temperature.
Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load
calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space.
Exceptions:
1. Attached single-and multi-family residential equipment sizing may be selected so that its cooling capacity is less than the
calculated total sensible load but not less than 80 percent of that load.
2. When signed and sealed by a Florida-registered engineer,in attached single-and multi-family units,the capacity of
equipment may be sized in accordance with good design practice.
O R403.6.1.2 Heating equipment capacity
• R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section
R403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load.
• R403.6.1.2.2 Electric resistance furnaces. Electric resistance fumaces shall be sized within 4 kW of the design
requirements calculated according to the procedure selected in Section R403.6.1.
• R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners
shall not be less than the design load calculated in accordance with Section R403.6.1.
O R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an
intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to
prevent continuous space cooling or heating within that space by one or more of the following options:
1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas.
2. A variable capacity system sized for optimum performance during base load periods is utilized.
❑ R403.7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections
C403 and C404 of the Commercial Provisions in lieu of Section R403.
❑ R403.8 Snow melt system controls(Mandatory). Snow and ice-melting systems,supplied through energy service to the building,shall
include automatic controls capable of shutting off the system when the pavement temperature is above 55°F,and no precipitation is falling
and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F.
❑ R403.9 Swimming pools,inground spas and portable spas(Mandatory). The energy requirements for residential pools and
inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSI/APSP-15.The energy
requirements for portable spas shall be in accordance with ANSI/APSP-14.
O R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on-off switch that is mounted
outside the heater to allow shutting off the heater without adjusting the thermostat setting.
R403.9.1.1 Gas and oil-fired pool and spa heaters. All gas-and oil-fired pool and space heaters shall have a minimum
thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013 when tested in accordance with ANSI Z 21.56.
Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights.
R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance
with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is
required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard.
O R403.9.2 Time switches. Time switches or other control method that can automatically turn off and on heaters and pumps according to a
preset schedule shall be installed on all heaters and pumps.Heaters,pumps and motors that have built in timers shall be deemed in
compliance with this equipment.
Exceptions:
1. Where public health standards require 24-hour pump operations.
2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems.
3. Where pumps are powered exclusively from on-site renewable generation.
O R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor-retardant cover on or
at the water surface or a liquid cover or other means proven to reduce heat loss.
Exception: Outdoor pools deriving over 70 percent of the energy for heating from site-recovered energy,such as a heat pump or
solar energy source computed over an operating season.
❑ RR404.1 Lighting equipment(Mandatory). A minimum of 75 percent of the lamps in permanently installed lighting fixtures shall be
high-efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps.
Exception: Low-voltage lighting shall not be required to utilize high-efficacy lamps.
O R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights
❑ R405.2 Performance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R-6.
O R405.2.1 Performance ONLY. Ceilings shall have minimum insulation of R-19.Where single assemby of the exposed deck and beam type or
concrete deck roofs do not have sufficent space, R-10 is allowed.
11/11/2017 1:06 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Com Page 3 of 3
FORM R405-2014
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: Cali 1828 Elev D Builder Name: DRH Express Homes
Street: Permit Office:
City,State,Zip: Zephyrhills, FL, Permit Number: _
Owner: Jurisdiction:
Design Location: FL,Tampa
COMPONENT CRITERIA CHECK
Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope.
Exterior thermal envelope contains a continuous barrier.
Breaks or joints in the air barrier shall be sealed.
Air-permeable insulation shall not be used as a sealing material.
Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the
insulation and any gaps in the air barrier shall be sealed.
Access openings,drop down stairs or knee wall doors to unconditioned
attic spaces shall be sealed.
Corners and headers shall be insulated and the junction of the foundation
Walls and sill plate shall be sealed.
The junction of the top plate and the top or exterior walls shall be sealed.
Exterior thermal envelope insulation for framed walls shall be installed in
substantial contact and continuous alignment with the air barrier.
Knee walls shall be sealed.
Windows, skylights and doors The space between window/doorjambs and framing and skylights and
framing shall be sealed.
Rim joists Rim joists are insulated and include an air barrier.
Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside
and cantilevered floors) of subfloor decking.
The air barrier shall be installed at any exposed edge of insulation.
Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently
attached.to the crawlspace walls.
Exposed earth in unvented crawl spaces shall be covered with a Class I
vapor retarder with overlapping joints taped.
Shafts, penetrations Duct shafts, utility penetrations,and flue shaft openings to exterior or
unconditioned space shall be sealed.
Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled
by insulation that on installation readily conforms to the available cavity
s aces.
Garage separation Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be
air tight, IC rated,and sealed to the drywall.
Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in
exterior walls,or insulation that on installation readily conforms to available
space shall extend behind piping and wiring.
Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air
barrier installed separating them from the showers and tubs.
Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or
air sealed boxes shall be installed.
HVAC register boots HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub-floor or drywall.
Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have
gasketed doors
1 1/1 1/2017 1:07 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software .Page 1 of 1
L
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Envelope Leakage Test Report
Prescriptive and Performance Method
Project Name: Cali 1828 Elev D Builder Name: DRH Express Homes
Street: Permit Office:'
City,State,Zip: Zephyrhills,FL, Permit Number:
Design Location: FL,Tampa Jurisdiction:
Cond. Floor Area:: 1828 sq.ft. Cond.Volume: 15849 cu ft.
Envelope Leakage Test Results Leakage Characteristics
Regression Data:
C: n: R:
CFM(50):
Single or Multi Point Test Data
HOUSE PRESSURE FLOW: ELA:
1 Pa cfm EgLA:
2 Pa cfm ACH:
3 Pa cfm
ACH(50):
4 Pa cfm
5 Pa cfm SLA:
6 Pa cfm
R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour
in Climate Zones 1 and 2,3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2
inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the
test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all
penetrations of the building thermal envelope.
During testing:
1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other
infiltration control measures;
2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration
control measures;
3.Interior doors,if installed at the time of the test,shall be open;
4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed;
5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and
6.Supply and return registers,if installed at the time of the test,shall be fully open.
I hereby certify that the above envelope leakage Where required by the code official, 13E STATE
performance results demonstrate compliance testing shall be conducted by an ,, , _ o,,�,
with Florida Energy Code requirements in approved third party. A written --
accordance with Section R402.4.1.2; report of the results of the test shall
be signed by the third party
conducting the test and provided to . ,
SIGNATURE: the code official. '
PRINTED NAME: WE
BUILDING OFFICIAL:
DATE:
DATE:
11/11/2017 1:07 PM EnergyGauge@ USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1
FORM R406 2014 Duct Leakage Test Report Performance Method
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION-
Form R405 Duct Leakage Test Report
Performance Method
Project Name: Cali 1828 Elev D Builder Name: DRH Express Homes
Street: Permit Office:
City,State,Zip: Zephyrhills, FL, Permit Number:
Design Location:- FL,Tampa Jurisdiction:
Duct Test Time: Post Construction
Duct Leakage Test Results
CFM25 Duct Leakage Test Values
Line System Outside Duct Leakage
1 System 1 cfm25(Out)
2 System 2 cfm25(Out)
3 System 3 cfm25(Out)
4 System 4 cfm25(Out)
5 Total House Sum lines 1-4
Duct System
Divide by
Leakage
(Total Conditioned Floor Area)
(Qn,Out)
I certify the tested duct leakage to outside, Qn, is
not greater than the proposed duct leakage Qn Duct tightness shall be verified by .o��gE STATE
specified on Form R405-2014. testing to Section 803 of the RESNET + , , r ti= 0,1,
Standards by an energy rater certified in
accordance with Section 553.99,
Florida Statutes. 994 b
SIGNATURE: '
PRINTED NAME: G,OU W-E
DATE: BUILDING OFFICIAL:
DATE:
11/11/2017 1:07 PM EnergyGaugeO USA-FlaRes2014 -Section R405.4.1 Compliant S Page 1 of 1
Manual S Compliance Report Job:
- - wrightsofto P p Date: Oct 10,2014
Entire House By:
Progressive Air Systems, Inc
5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669
Project • •
For: DR Horton/Express
Lot 25 Blk 6 Silverado Ranch, Zephyrhills, FL
Cooling Equipment
Design Conditions
Outdoor design DB: 91.2°F Sensible gain: 20798 Btuh Entering coil DB: , 75APF
Outdoor design WB: 77.1 OF Latent gain: 2966 Btuh Entering coil WB: 62.7°F
Indoor design DB: 75.0°F Total gain: 23764 Btuh
Indoor RH: 50% Estimated airflow: 1000 cfm
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: SpIitASHP.
Manufacturer: Carrier Model: CH14NB030****A+FB4CNP030
Actual airflow: 1000 cfm
Sensible capacity: 23270 Btuh 112%of load
Latent capacity: 3914 Btuh 132%of load
Total capacity: 27184 Btuh 114%of load SHR: 86%
Heating Equipment
Design Conditions
Outdoor design DB: 40.0°F Heat loss: 21100 Btuh Entering coil DB: 69.8°F
Indoor design DB: 70.0°F
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: SpIitASHP
Manufacturer: Carrier Model: CH14NB030****A+FB4CNP030
Actual airflow: 1000 cfm -
Output capacity: 25604 Btuh 121%of load Capacity balance: 32 OF
Supplemental heat required: 0 Btuh Economic balance: -99 OF
Backup equipment type: Elec strip
Manufacturer: Model:
Actual airflow: 1000 cfm
Output capacity: 6.6 kW 1070/6 of load Temp. rise: 20 OF
Meets are all requirements of ACCA Manual S.
wri htsofta 2017-Nov-11 13:07:37
9 Right-Suite®Universal 2017 17.0.21 RSU25554 Page 1
�� ...on\Wrightsoft Files\Express homes\Cali 4EBB.rup, Calc=MJ8 House faces:NE
Date:
t F d Sho
rt-�- wrightsoft® vase: Oct io,2014
Entire House By:
Progressive Air Systems, Inc
5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3698 Fax:727-815-3399 License:CAC033669
Project • •
For: DR Horton/Express
Lot 25 Blk 6 Silverado Ranch, Zephyrhills, FL
Design Information;
Htg Clg Infiltration
Outside db(OF) 40 91 Method Simplified
Inside db(OF) 70 75 Construction quality Semi-tight
Design TD (OF) 30 16 Fireplaces 0
Daily range - L
Inside humidity (%) 50 50
Moisture difference(gr/lb) 26 54
HEATING EQUIPMENT COOLING EQUIPMENT
Make Carrier Make Carrier
Trade CARRIER Trade CARRIER
Model CH14NB030****A Cond CH14NB030****A
AHRI ref Coil FB4CNP030
AHRI ref
Efficiency 8 HSPF Efficiency 11.5 EER, 14 SEER
Heating input Sensible cooling 22560 Btuh
Heating output 29600 Btuh @ 47°F Latent cooling 7500 Btuh
Temperature rise 27 OF Total cooling 30000 Btuh
Actual air flow 1000 cfm Actual air flow 1000 cfm
Air flow factor 0.047 cfm/Btuh Air flow factor 0.048 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.88
Capacity balance point=32 OF
Backup:
Input=7 kW, Output= 22477 Btuh; 100 AFUE
ROOM NAME Area Htg load Clg load Htg AVF Clg AVF
(ft2) (Btuh) (Btuh) (cfm) (cfm)
M bed 194 3196 2983 151 143
living room 270 2891 3511 137 169
kitchen/dining 349 4292 4955 203 238
bed3 155 1420 1524 . 67 73
bath2 55 604 281 29 14
bed2 168 3411 2467 162 119
we 21 24 36 1 2
M bath 114 1276 909 60 44
M Wic 66 77 113 4 5
laundry 39 45 674 2 32
bed4/den opt 169 1866 1736 88 83
A/C closet 19 181 115 9 6
foyer 200 1817 1495 86 72
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2017-Nov-1113:07:37
� wrihtsoft6 g Right-Suite®Universal 2017 17.0.21 RSU25554 Page 1
...on\Wrightsoft Files\Express homes\Cali 4EBB.rup Calc'=MJ8 House faces:NE
Entire House d 1820 21100 20798 1000 1000
Other equip loads 0 0
Equip. @ 1.00 RSM 20798
Latent cooling 2966
TOTALS 1820 21100 23764 1000 1000
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wri htsoft, 2017-Nov-1113:07:37
9 Right-Suite®Universal 2017 17.0.21 RSU25554 Page 2
ACCK ...on\Wrightsoft Files\Express homes\Cali 4EBB.rup Calc=MJ8 House faces:NE
Project Summary Job:
-�- wrightsoft" Date: Oct 10,2014
Entire House By:
Progressive Air Systems, Inc
5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669
Proiect Information,
For: DR Horton/Express
Lot 25 Blk 6 Silverado Ranch, Zephyrhills, FL
Notes:
Design Inf6rmation
Weather: Tampa Intl AP, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 40 OF Outside.db 91 OF
Inside db 70 OF Inside db 75 OF
Design TD 30 OF Design TD 16 OF
Daily range L
Relative humidity 50 %
Moisture difference 54 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 17539 Btuh Structure 16200 Btuh
Ducts 3561 Btuh Ducts 4598 Btuh
Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh
(none) (none)
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 21100 Btuh Use manufacturer's data y
Rate/swing multiplier 1.00
Infiltration Equipment sensible load 20798 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Semi-tight
Fireplaces 0 Structure 2360 Btuh
Ducts 606 Btuh
Central vent (0 cfm) 0 Btuh
Heating Cooling (none)
Area(ft2) 1820 1820 Equipment latent load 2966 Btuh
Volume(ft3) 16012 16012
Air changes/hour 0.26 0.14 Equipment total load 23764 Btuh
Equiv.AVF(cfm) 69 37 Req. total capacity at 0.75 SHR 2.3 ton
Heating Equipment Summary Cooling Equipment Summary
Make Carrier Make Carrier
Trade CARRIER Trade . CARRIER
Model. CH14NB030****A Cond CH14NB030****A
AHRI ref Coil FB4CNP030
AHRI ref
Efficiency 8 HSPF Efficiency 11.5 EER, 14 SEER
Heating input Sensible cooling 22500 Btuh
Heating output 29600 Btuh @ 47OF Latent cooling 7500 Btuh
Temperature_rise 27 OF Total cooling 30000 Btuh
Actual air flow 1000 cfm Actual air flow 1000 cfm
Air flow factor 0.047 cfm/Btuh Air flow factor 0.648 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat. Load sensible heat ratio 0.88
Capacity balance point=32 OF
Backup:
Input=7 kW, Output=22477 Btuh, 100 AFUE
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
WI'1 I1tS0ft° 2017-Nov-1113:07:37
g Right-Suite®Universal 2017 17.0.21 RSU25554 Page 1
/R. ...on\Wrightsoft Files\Express homes\Cali 4EBB.rup Calc=MJ8 House faces:NE
FORM R4Q5-2014.
RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST
Florida Department of Business and Professional Regulation
Simulated Performance Alternative (Performance)Method
Applications for compliance with the 2014 Florida Building Code, Energy Conservation via the
residential Simulated Performance method shall include
❑ This checklist
❑ A Form R405 report that documents that the Proposed Design complies with Section
R405.3 of the Florida Energy Code. This form shall include a summary page
indicating home address, a-ratio and the pass or fail status along with summary
areas and types of components, whether the home was simulated as a worst-case
orientation, name and version of the compliance software tool, name of individual
completing the compliance report(1 page)and an input summary checklist that can
be used for field verification (usually 4 pages/may be greater).
❑ Energy Performance Level(EPL) Display Card(one page)
❑ Mandatory Requirem6nts(three pages)
Required prior to CO for the Performance Method:
❑ Air Barrier and Insulation Inspection Component Criteria checklist(Table R402.4.1.1 -
one page)
❑ A completed Envelope Leakage Test Report(usually one page)
❑ If Form R405 duct leakage type indicates anything other than "default leakage", then a completed
Form R405 Duct Leakage Test Report(usually one page)
EnergyGauge®-USRCZB v5.1
1 1/1 1/2017 1 2:48:47 PM Page 1 of 1
CITY OF / / / / BUILDING
ZEPHYRHILLENOTICE DEPARTMENT
OE ADDITION OR CORRECTION
DO' NOT REMOVE
ADDRESS DATE PERMIT
THIS JOB HAS NOT BEEN COMPLETED. The following additions or corrections shall be made before the job
will be accepted.
CAP r�r
Wlloeqex AWcl-r have f
It is unlawful for any Carpenter,Contractor,Builder,or other persons,to AFTER CORRECTIONS ARE MADE CALL
cover or cause to be covered,any part of the work with flooring,lath,earth 780-0020 FOR RE-INSPECTION
or other material,until the proper inspector has had ample time to approve
the installation.
OFFICE HOURS 7:30AM-4:30 PM MON.-FRI. INSPECTOR Z�z
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Envelope Leakage Test Report
Prescriptive and Performance Method
Project Name: SILVERADO Builder Name: D R HORTON / I
Street: 6549 Wagon Trail St Permit Office: C( r �P-AVrh"t(S
City,State,Zip: Zephyrhills,FL 33541 Permit Number:
Design Location: 6549 Wagon Trail St(Lot 25) Jurisdiction: (Q C &OD
Cond.Floor Area: 1828 Cond.Volume: 16086
Envelope Leakage Test Results Leakage Characteristics
Regression Data:
C: n: R:
CFM(50): 1661
Sin le or Multi Point Test Data
ELA: 91
HOUSE PRESSURE FLOW:
1 50 Pa 1661 cfm EgLA: 216
ACH: 6.2
2 0 Pa 0 cfm
SLA: .05
3 0 Pa 0 cfm
4 0 Pa 0 cfm ACH(50)': 6.2
.For prescriptive projects,tested leakage must be—7
5 0 Pa 0 cfm ACH(50). For performance projects, tested leakage
must be—the ACH(50)shown on Form R405-2014
6 Pa cfm for this project.
R402.4.1.2 Testing.The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zones 1
and 2.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Testing shall be conducted by either individuals as defined in
Section 553.993(5)or(7),Florida Statutes or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party.A written report of the
results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all
penetrations of the building thermal envelope.
During testing:
1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other
2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration
3.Interior doors,if installed at the time of the test,shall be open;
4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed;
5.Heating and cooling systems,if installed at the time of the test,shall be tumed off;and
6.Supply and return registers,if installed at the time of the test,shall be fully open.
I hereby certify that the above envelope leakage performance results
demonstrate compliance with Florida Energy Code requirements in
accordance with Section R402.4.1.2.
Testing shall be conducted by either individuals as
defined in Section 553.993(5)or(7),Florida Statutes 0,1-IRE5r9r�
or individuals licensed as set forth in Section �� o €:
489.105(3)(f),(g),or(i)or an approved third party.A
written report of the results of the test shall be signed n �
Digitally signed by Michael by the third party conducting the test and provided to y"ji }
Silberstein the code official. i�o
Date:2018.08.2810:49:33 EDT Z
CN=Michael Silberstein,O=TopBuild •lN ('
Home Services,OU, G'Op we—
EMAI LADDRES S=Mich ael.S ilb erste i
Signature: n@topbuild.com,C=US I
Printed Name:
Michael Silberstein BUILDING OFFICIAL:
Date: 08/28/2018 DATE:
Thank you for allowing TopBuild the opportunity to provide the above services for you.Please feel free to contact me with any questions.
10/25/2017
391905
5335 -8TH STREET
(813)780-0020
CERTIFICATE OF OCCUPANCY
Address: 6549 WAGON TRAIL ST Owner: DR HORTON INC
ZEPHYRHILLS, FL. 12602 TELECOM
TEMPLE TERRA(
Subdiv: SILVERADO
Parcel: 05_26-21-0080-00600-0250 Work Type: 101-NEW CONS1
Construction Type: NOT APPLICABLE ❑ Sprinklers
Use Classification: NOT APPLICABLE
Permit Number: 19586
Date: 9/06/2018
ISSUED BY: BUILDItt
"Y'ISSUED
BE C WATER MUST BE CHANGED OVER WITHIN 10DAY.5 OF J
DEPOSIT
L GARBAGE DEPOSIT MUST BE APPLIED pRrOR ro IS,
R
,OR
..� -�- _.
I