Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
18-19587
CITY OF ZEPHYRHILLS 5335-8TH STRE t.�; (813)780-0020_ 19587 BUILDING PERMIT SINGLE:FAMILY RESIDENTIAL PERMIT INFORMATION - - LOCATION INFORMATION Permit#:19587 Issued: 4/26/2018 Address: 6557 WAGON TRAIL ST Permit Type: NEW SINGLE FAMILY DWELLING ' - ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 347,525.25 Total Fees: 11,759.19 Subdivision: SILVERADO Amount Paid: 11,759.19 Date Paid: 4/26/2018 Parcel Number: 05-26-21-0080-00600-0260 CONTRACTOR INFORMATION OWNER INFORMATION Name: DR HORTON INC Name: DR HORTON INC Addr: 12602 TELECOM DR Address: 12602 TELECOM DR TAMPA, FL. 33637 TEMPLE TERRACE FL 33637-0935 Phone: Lic: Phone: 813-549-1968 Work Desc: CONSTRUCT SINGLE FAMILY HOME 3,085 SQ FT APPLICATION FEES BUILDING FEE 1,336.64 ELECTRICAL FEE 277.20 PLUMBING FEE 184.80 MECHANICAL FEE 129.36 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE-sfr/100% 4,828.00 .SCHOOL IMPACT FEE-sfr/1% 48.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32 J�b Inspections Required FOOTER 2ND ROUGH PLUMB Misc INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRACTORS SIGNATURE PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIOlf CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER 5335 - 8TH STREET (813)780-0020 CERTIFICATE OF OCCUPANCY Address: 6557 WAGON TRAIL ST Owner: DR HORTON INC ZEPHYRHILLS, FL. 12602 TELECOM DR Subdiv: SILVERADO TEMPLE TERRACE FL 33637-0935 Parcel: 05-26-21-0080-00600-0260 Work Type: 101-NEW CONST/SFR Construction Type: NOT APPLICABLE ❑ Sprinklers Use Classification: NOT APPLICABLE Permit Number: 19587 Date: 8/20/2018 ISSU D BY--- BUILDI OFFICIAL : WATER MUST BE CHANGED OVER WITHIN 10 DAYS OF ISSUANCE GARBAGE DEPOSIT MUST BE APPLIED FOR PRIOR TO ISSUANCE O City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: Ty Date Received: Q Site: Permit Type: Approved w/no comments:❑ Approved w/the below comments: Denied w/the below comments: ❑ see. S This comment sheet shall be kept with the permit and/or plans. Kalvin Switz Plans Examiner Date Contractor and/or Homeowner (Required when comments are present) DR Horton-6557 Wagon Trail St-3,085 sq ft- o umn SQ. FEET PRICE MAIN OR LIVING: 3,085 $ 112.65 OTHER AREA UNDER ROOF: - $ - OTHER: - $ - VALUATION $ 347,525.25 FEE SHEET $ 1,232.00 ADDRESS $ 40.00 DRIVEWAY $ 40.00 BUILDING: $ 1,336.64 ELECTRICAL: $ 277.20 PLUMBING: $ 184.80 MECHANICAL: $ 129.36 SUB-TOTAL $ 1,928.00 TOTAL $ 1,928.00 SEWER: WATER: IRRIGATION: $ - TOTAL: $ - WATER METER: IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: $ - INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 2,481.35 PARK IMPACT FEES $ 769.56 SIF'S: $ 4,828.00 100.0% $ 4,828.00 1.0% $ 48.28 TOTAL: $ 4,876.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 11,759.19 INSTR#2O1$OGS725J OR BK 9711 PG 2303 Page 1 of 1 04/19/2018 10:56 AM Rcpt:1950015 Rec:10.00 DS:0.00 IT:0.00 Paula S.ONef6 PhD.,Pasco County Clerk&Comytroller Permit No. Parcel IDN0a5-C,2��65'���ab 01�� NOTICE OF COMMENCEMENT State of O I I CL__ County of THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 713,Florida Statutes, the following information Is provided in this Notice of Comme ceme / l,t0 � 1. Description of Pro erty: Parcel I`d'enti�ficatiio¢n�N,-o.. 1 �f. _ �Q l V � 2 /b � Street Address: / lA-1..L O r -ZLl 1rh\ I r �J�`Y/ 2. General Description of Improvement t r 3. Owner Information or Lessee Information if the Lessee contracted for the Improvement: -0- R- d ol'�a n fit)c, 17-602-. (-erennn "ter <,gaa J36Z LL Address C I City— State Interest in Property: Name of Fee Simple Titleholder. (If different from Owner listed above) Address n tjMr�:a� City State 4. Contractor. p� lY1 )1�00, `"T2f eco-M r T Nr1 d�Q 13 J 7 err Address City_ r State Contractoes'. 1 Telephone No.: N 5. Surety: /a Name' Address A/ City State Amount of Bond: $ A f Telephone No.: 6. Lender, Name` Address city State Lenders Telephone No.: 7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)(7),Florida Statutes: Name Address State Telephone Number of Designated Person: /,n�-f 8. In addition to himself,the owner designates _�//i of to receive a copy of the Lienors Notice as provided in Section 713.13(1)(b),Florida Statutes. Telephone Number of Person or Entity Designated by Owner. 9. Expiration date of Notice of Commencement(the expiration date may not be before the completion of construction and final payment to the contractor,but will be one year from the date 0f recording unless a different date is specified): WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalty of perjury.I declare that I have read the foregoing notice of commencement and that the facts stated therein are true to the best of my knowledge and belief. STATE OF FLORIDA COUNTY OF PASCO Signa re of Owner or Lessee,or Owners or Lessee's Authorized Officer ireclor/PartnerlManager ASS �n�1'p r,/ - 7• f-{nlr��� Sig tory's Titie/Office The foregoing instrument was acknowledged before me this 1kday of r) 20t�(by_ M ep CV) as_? ��• 1e�`Q/�/ (type of authon e.g.,officer,trustee,attorney in fad)for n n ' 4 -C (name of party on b ha f whom instrument was executed). Personally Known�OR Produced Identification❑ Notary Signatu e lr ��� Type of Identification Produced Name(Print) Hof°�rG. Notary Public State of Fladde s� M Moyes gc',�r3r ply CoM Commissdon GG 057321 9r%wtN F-Vbvs 12I212o20 wpdata/bcs/n oticecomm encement-pc053048 D.R. Horton-6557 Wagon Trail.St-3085 sq ft Column Es SO. FEET PRICE MAIN OR LIVING: 3,085 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ _ VALUATION $ 347,525.25 FEE SHEET $ 1,232.00 ADDRESS $ 40.00 DRIVEWAY $ 40.00 BUILDING: $ 1,336.64 ELECTRICAL: $ 277.20 PLUMBING: $ 184.80 MECHANICAL: $ 129.36 SUB-TOTAL $ 1,928.00 TOTAL $ 1,928.00 SEWER: $ 01 no WATER: $ k6 1.0� IRRIGATION: $ v - TOTAL: $ 401.00 WATER METER: $ 473. IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 5,606.13 PARK IMPACT FEES $ 769.56 SIF'S: $ 4,828.00 100.0% $ 4,828.00 1.0% $ 48.28 TOTAL: $ 4,876.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 14,883.97 Single Family DWe ling . . P1 an-Review Coinments 1. F.F:E. shall be a minimum.o. above.the road.elevation and an engineered site plan. :. . 2.. Lots shall be graded to comply with R401.3 of the F.B:.C: .3. Compaction test required.if 24 or more of fill dirt is brought in:at anyone place: . . : ... A.*. :Tie in' survey required before pouring concrete. 5. Driveways require a R:O.:W.use permit:. All-4 sides of.driveway thru the sidewalk shall Have. expansion material: . . 6. All.setbacks.shall be met. T. All.property.markers'shall be.uncovered and marked at time of first inspection: 8: All A.D;A:requirements shall be met.:'. 9. No electric lumbfn . _ . . p g,-mecliariical;,or framing shall be covered without an.inspection.and . approval first. 10. All Garag .e shall:comply with:section R302:6.of the F.B.C.. Fire-Separation).. aration s c p. 11. Appliances::shall iiot:be installed in:a location'where subject to.mechanical damage unless. :protected'by approved barriers. M3014 of the F.B.C. 12. Water heaters shall comply.with section:P607.3 of the F:B.C: 13. Foundation supports for.A/C units shall be raised at least 3'.' above finished grade.. M1308.1 14. Return air in all bedrooms. F.B.C. .M1620.4., 15. Smoke detectors'are to beinstalled,in-accordance:withi R313.1 of ihe:F.B.C. .16:.A11 glazing requirements are to be in accordance with R308.4_of the F.B.C. .17. All means of egress are to be in:accordance with.R311:.of the F:B.C.. .: : 18.'`.`Green gypsum.board shall-riot be used:' a backer irishowers or tubs.-R7014:2 F.B.C. _ . . 19. Combination-type AFCI breakers.are required.at all locations requiring an AFCl type breaker: : . 20.;Carbon monoxide.alarms will.be required in-new construction that uses fossil-burning heating' or appliances or an attached garage:, They shall be.installed in accordance with.the F.B.C. 21. All plumbing,mechanical,:and electrical shall-be separate from unit to:unit: This includes all underground plumbing and electric: 22. All 2008:N.E.C. Codes will,be enforced.. 23:,Tamper=Resistant Receptacles in accordance with 406:1 l of the 2008 N.E:C In accordance.with the Land.Development.Code,lots.shall be sodded before final at least 10 feet,around the.structure: 25 A.copy of the enemy cads shall be with:pernzitat all times. 26 Copy of final insulation report shall be.prbvided with.permit.before.fz� F:F:E:-Finished Floor Elevation F.B.C_-Florida Building Code P Edition: R.O.W-Right of Way A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2008). - PLOT PLAN DESCRIPTION:(AS FURNISHED) LOT 26, BLOCK 6, SILVERADO RANCH SUBDIVISION PHASE 6, 8 & 9A AS RECORDED IN PLAT BOOK 75, PAGE(S) 75-80, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. 4PT I - I I I I LOT 27 i I BLOCK 6 / 6 661 4 (REFERENCE BEARING) \0 �0 ' I �p6• (NON-RADIAL) S87°24 28" 124 E �D's .86' N87'24-28-W 2 A - - a6.o2-------\ I — — — — — — • — . o s 1n 27,7" 9 GL U, 'goal a P�O :;.t: r': otyyj ail N �..:' 'O_. '.(�..�..:: : ':•^ \ vJQ��� 60.2' 0 ,• \\ y''o p \ } a I N w 1 yp 601� o C) N n I m .o O ion { \ y o I i„� 0 , O u n o. ^+ UZa nl , P �N6, 426I n PC ni =0,0 ZI Ix U N LLI CV 110•�05' I r\-.J l' Curve Table Curve Length Radius Delta Chord Bearing Chord UU-) \ � 108.2 C1 40.54' 54.86' 42'20'2B' S1744'13'E 39.63' ON C2 151.99' 155.00' 55'10'54' S25'29'55'E 145.97' O \"rs\ �' ;V �Q�G� C3 71.10' 155.00' 2676'52' S70'32'54'E 70.4B' � C4 80.89' 155.00', 29'54'02' S38'38'21'E 179.97' POE =�'�\� _0\ � 108. SUMP AREA. \ \ - ON LOT CALCULATIONS LOT = 12,926 SO. VT. y5 LIVING AREA = 1,104 SQ. FT. GARAGE = 437 SO. FT. ENTRY = 53 SQ. FT. 2 „ LANAI = 0 SQ. FT. 2S SS'� DRIVEWAY = 4117 SQ. FT. A/C PAD = 12 SQ. FT. WALKWAY = 30 SQ. FT. PRIVArE TRACT 8 IMPERVIOUS = 17% "AND A" = 2133 SQ. FT. ARE SEV SOD = 10,793 SQ. FT. CON PREPARED FOR: A AnQN z OFF LOT CALCULATIONS 1" = 30, RIGHT OF WAY = 466 SO. FT. �)64HOWN .n � GRAPHIC SCALE DRIVE APRON. = 158 SQ. FT. N rrt. PUBLIC S/W = 194 SQ. FT. HiGf"1Cci�s'C61�E 1011 0 15 30 SOD = 114 SQ. FT. TOTALS BUILDING SETBACKS AREA = 13.392 SO. FT. DRIVEWAY = 575 SQ. FT. FRONT: 22' SIDEWALK = 224 SQ. FT. REAR: 15, SOD = 10.907 SQ. FT. SIDE: 7.5' SIDE STREET: 20' LEGEND: NOTES: — — — BUILDING SETBACK LINE PI POINT OF INTERSECTION PC POINT OF CURVATURE 1. ELEVATIONS SHOWN ARE PER LOT GRADING - CENTERLINE PT POINT OF TANGENCY PLANS PROVIDED BY THE CLIENT. — - - — RIGHT OF WAY LINE RP RADIUS POINT 2. ELEVATIONS ARE BASED ON NAVD 1988 XX PRC POINT OF REVERSE CURVATURE DATUM. PROPOSED ELEVATION FCC POINT OF COMPOUND CURVATURE TYP TYPICAL PROPOSED DRAINAGE FLOW CS CONCRETE SLAB THIS PLOT-PLAN IS INTENDED FOR PERMITTING PURPOSES CONCRETE (P) PER RCALCPLAT LATED ONLY. THIS IS NOT INTENDED FOR THE CONSTRUCTION OF A/c AIR CONDITIONER PB " PLAT BOOK THE PROPOSED HOUSE. REFER TO HOUSE PLAN AND, PGS PAGES OPTION LIST FOR CONSTRUCTION. ALL BUILDING SET BACK S/w SIDEWALK SQ. FT. SQUARE FEET LINES SHOWN HEREON IS PER DATA FURNISHED BY CLIENT F.E.M.A. FEDERAL EMERGENCY MANAGEMENT AGENCY AND IS FOR INFORMATIONAL PURPOSES ONLY. F.I.R.M. FLOOD INSURANCE RATE-MAP NAVD NORTH AMERICAN VERTICAL DATUM NG NATIONAL GEODETIC VERTICAL THIS IS NOT A SURVEY D&UE .. DRAINAGE&UTILITY EASEMENT ATOM E PRIVATE DRAINAGE THIS IS A PLOT PLAN ONLY UE UTILITY EASEMENT(PUBLIC)EASEMENT FLOOD NOTE! SURVEYOR NOTES: I HAVE EXAMINED THE F.I.R.M. MAP NO. 12101CO288F, 1. THE SURVEYOR HAS NOT ABSTRACTED THE DATED SEPTEMBER 26, 2014. AND FOUND THE SUBJECT PROPERTY LAND SHOWN HEREON FOR EASEMENTS, RIGHT APPEARS TO LIE IN ZONE'X% AREAS DETERMINED TO BE OUTSIDE THE OF WAY, RESTRICTIONS OF RECORD WHICH 0.2%ANNUAL CHANCE FLOODPLAIN. THE SURVEYOR MAKES NO MAY AFFECT THE TITLE OR USE'OF THE LAND. ' GUARANTEES AS TO THE ABOVE INFORMATION. PLEASE CONTACT THE LOCAL F.E.M.A. AGENT FOR vERlFlcnnoN. 2. NO UNDERGROUND IMPROVEMENTS HAVE BEEN LOCATED EXCEPT AS SHOWN. BEARING BASIS: BEARINGS SHOWN HEREON ARE BASED ON THE NORTH LINE OF LOT 26 A5 hR 3. NOT VALID WITHOUT THE AUTHENTIC BLOCK 6 BEING SB7'24'28'W. PER PLAT. ELECTRONIC SIGNATURE AND THE AUTHENTIC ELECTRONIC SEAL OF A FLORIDA LICENSED REVISED: A M,E R I CA N SURVEYOR AND MAPPER. (FIELD DATE:) S U F-;,'\/E Y I N G SCALE: 1'= 30 FEET i Sc MAPPING INC. y"ac ZON:a=lamp WBolems�o=Nrehan APPROVED BY: J9 ?%..-.`=u." CERTIFICATION-OF AUTHORIZATION NUMBER L3#6393 e a u=lmlananoamc«wi+alemm.r-us 3191 MAGUIRE BOULEVARD, SUITE 200 #o%q �; Oa a]UL].11:1604]B93-0S p FOR JOB NO. 171D13 LOT 26. BILK 6 ORLANDO, FLORIDA 32803 aM`iap THE FIRM (407) 426-7979 DATE DRAWN BY: DSB pLOT PLAN 11 13 17 KJW WWW.AMERICANSURVEYINGANDMAPPING.COM JAMES W. BOLEMAN PSM# 6485 813-780-0020 City of Zephyrhi116 Permit Application Fax=813-780 a021 Building Department Date Received Phone Contact for Permitting -- 'TT- �` p Owner's Name C1 r c� !-. �= Owner Phone Numbert1 C' fJ Owner's Address � E f�a,Z j e rt=`� '""" p ti" TGn^f -� �'f Owner Phone Number —� Fee Simple Titleholder Name r-i Owner Phone Number -Fee Simple Titleholder Address JOB ADDRESS' . �70j) L-�QPJJ� 33241 LOT# .SUBDIVISION G—AG) PARCEL ID# (OBTAINED FROM PROPERTY TAX NOTICE) ' WORK PROPOSED NEW CONSTR ADD/ALT SIGN DEMOLISH 'INSTALL_ R REPAIR PROPOSED.USE F-79"-- SFR COMM OTHER TYPE OF CONSTRUCTION . �� BLOCK F__1 FRAME STEEL = DESCRIPTION OF WORK C t-� :>'a`�1���rv�) � t)�`'J c}C��,'►C � � II�J C�cs� 3 k2,c;i-44 t BUILDING SIZE �— SO FOOTAGE HEIGHT C "TTr^r<-rt-rlrrr-r-s-r-rrr "rt-rTmr-r-9"� rrs-mrmr-r'e"Trr'v�rT�=�"r-�'r>ru-'-a-Ir =BUiLDiNG $ VALUATION OF TOTAL CONSTRUCTION 066 =ELECTRICAL $,- AMP SERVICE = PROGRESS ENERGY W.R.E.C. � ..00 [�PLUMBING $ 50 =MECHANICAL $ r VALUATION OF MECHANICAL INSTALLATION =GAS �( ROOFING 0 SPECIALTY OTHER FINISHED FLOOR ELEVATIONS Ug- ) -FLOOD ZONE AREA =YES NO ' U •'I- - :i- - -1^-3-- --t- -1 -�-�-�A-•F-:--1�4- -W--0-I - A 3 B--3-;C�: -I-r1-�G-E�-`-r-9-6�:- 6 te3-i�-9--G-t-•�- BUILDER � _ COMPANY J/► - J C)'-"�'c�r"`, f`+r� SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address %cca� /� l�'<i�.'�J .� f l�i�-r License# ELECTRICIAN ( .�' � , -�'',�- COMPANY ° SIGNATURE REGISTERED Y/ N FEE CURREN Y/N .. Address 4�' -. y j=iPOnL°" ,?'� � License# � Q%� t�• % �J� PLUMBER — COMPANY =/'1JA:VX - Ch'Af1?' .SIGNATURE �J REGISTERED Y/ N FEE CURREN �Y+�/_N/ r Address X ;l r� mot/ fi�Ec License# MECHANICAL J � r ''-' -_ --_ COMPANY I( '� ���ft SIGNATURE ( �' C REGISTERED W/ N FEE CURREi\ Y/N Address �J �.� �` f?JZ c«� r'rt! 1` ! ' License# r ,7, OTHER. w � .- - ? COMPANY fall iG >f�/".y/e't)j? c am '� (�`a°-//-I• SIGNATURE pp REGISTERED Y/ N FEE CURREN Y/N e Address ti !'f " License# Liil1 ! lih111TilliltllllTill [ Iiiitliillllltllllllll .11iIlll Ill fill IaI'1 RESIDENTIAL Attach(2)Plot Plans; (2)sets of Building Plans; (1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt.Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach (2)complete sets of Building Plans plus a Life Safety Page; (1)set of Energy Forms,R-O-W Permit for new construction. Minimum ten (10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SiGN PERMIT Attach (2)sets of Engineered Plans. "PROPERTY-SURVEY required for all NEW construction. Directions: ct..1-.1...I-B-i tions: Fill out application completely. Owner�Contractor sign back of application,notarized ` If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500) Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter.from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences (Plot/Survey/Footage) Driveways-Not over Counter if on public roadways,.rieeds ROW ' ~ NOTICE OF DEEDRESTRICTIONS: The undersigned understands that this permit may be subject ho'deed~ resthotioneC whk:honayba more restrictive than County regulations. The undersigned assumes responaibi| ' for curnp\iancevv�h any ' appUoab|edeed reathotionm. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired e contractor or contractors to undertake work, they may be required to be licensed in accordance with state and-local ,agu|e1/ona. If:the contractor is notAnenaad as required by \aw, both the owner and contractor may be cited for a misdemeanor violation under oiutm law. If the owner or intended-contractorAre uncertain as to what |\oeno|nQ requirements may Apply for the intended work, they are advised to contact the Pasco County Building Inspection Division--Liceha|ng Section ai727-847- ` 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) aign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as th� contractor, that maybe an indication that he is not properly licensed and is not entitled to permitting privileges,in paaou County. ' TRA0SPORTuT|[>@IK0P&Cl/UTlLIT\ES IMPACT AND RESOURCE RECOVERY FEES: Thoundens|gnadunderstands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing bui|d|ngo, or expansion of existing bu||d|ngo, as specified in Pasco County Dnd|Danoa number 89'07 and 00'07. aa'annended. The undersigned also undanatands, that such fees, as may be dua, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Faao.munt be paid prior to receiving a ^oert�cataof occupancy" or final power release. |f the project does not \nvok/eace�i�oadeof occupancy or final.power ro|ease. the fees must ba paid prior to permit issuance. Furthermore, if Pasco-County Water/Sewer Impact fees are due,they must.be paid prior to permit issuance in accordance with applicable Pasco County ordinances, CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation ofvtorh is $2.500.00 or more. | certify that |, the applicant, have been provided with a copy of the "Florida Construction, Lien Lmvv—Honneoxvner's . Protection Guide" pnapenad by the Florida Department of Agriculture'and Consumer Affairs. If the,applicant is aonnoonm other than the"owner", I certify that I have obtained a copy of the above described document and promise in good.faith to deliver dto the^owner' prior tocommencement. � C<]NTRACTCj8i'SIOVV0ERISAFFIDAVIT: | certify that all the information in this application ks accurate and that all work will be done in compliance with all applicable |avve regulating onnatruotion, zoning and. land development. Application is ` hereby made to obtain a permit to do work and installation as indicated. | certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating oonStruction. County and City codes; zoning regu|otione, and land development regulations.inthe jurisdiction. \ also � certify that ! understand that the regulations of other government agencies may apply to the intended work, And that it Is responsibility what Suuhogenciasinc|UdebutaronotUno�edkz nlyr�spona ^ identify . ' Department ofEnvironmental Protection-Cypress Boyheads. Wetland Areas and Environmentally Sensitive � Lands;Water/Wastewater Treatment. - Southwest Florida Water Management D\stdct4NeUo, Cvonaos. 8ayheada, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. ` - Department of Health & Rehabilitative Sen/icao/Environmanta| Health UnU-NeUs, Wastewater Tree1nuant.� Septic Tanks. _ - US-Environmental Protection AQency-Aabo8toeabatement. - Federal Aviation Authorhy-Runwdym. | understand that the following restrictions apply to the use offill: - Use of fill io not allowed in Flood Zone"V" unless expressly permitted.- If the fill material is to be used in Flood Zone ''/Y'` |t is understood that o drainage plan addressing a "compensating volume" will be submitted st time of permitting which is prepared byaprofessional engineer licensed by the State OfFlorida. - If the fillmaterial is to be used in Flood Zone ^Af in connectionvv(th o permitted building using stem wall construction, \ certify that fill will be used only to fill the area within the stem wall. ' If fill material is to be used in any area. \ certify that use of such fill will not adversely affect adjacent � ' propertiao. If use of,fi|| is found to adversely affect adjacent properties, the owner may be cited for violating ' the conditions of the building permit issued under the attached permit application, for lots |eao t an one M\ acre which are elevated by fill, an engineered drainage plan is requi[ed. h | amthe AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions Set forth in this affidavit prior to commencing construction. understand unde ��nd that asepapermit may permit be required for electrical work, wells,p|umbing' oigns, w� �. puo|a, air conditioning, gas,,or other installations not specifically included.in the application. /\ permitiosuedsha|| benonsthuedtobea |icensetopnooeedvvith-thevvnrkendnotauauthurKytnvio|ate. manoe|. altar. or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring aoomact�nof errors-in plans, construction nr violations ofanycodes. Every permit issued shaUbecome invalid unless the work authorized by such permit is commenced within six months of permit iasuanne, or if work authorized by the permit |a suspended or abandoned for a period,of six (G) months after the time the Work iacommenced. An extension may be requested, in vvhUng^ from the Building Official for a period not to exceed ninety (QC) days and will demonstrate ` justifiable nousefo[theextension. |f work ceases for ninety /8O\ consecutive days,the job ie considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE 0 .F COMMENCEMENT MAY RESULT IN YOUR.* PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTENDCONSULT , ,WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE-bF-C'OMMENCEMENT.' OWNER OR AGENT CONTRACTORSubscribed and sw n to(or am Gubaoiueu and sworn to(or by uood vv:om/ae personallyxnown to me or has/have ~ Identification.- ' � as ~ ,.a.',"""^ CommissionNo.. CommisslnnNv ` �V( ' Name of Notary typed,printed or stamped Name of . Notary typed,printed—_- stamped- __ EMichelin MOY0 v., Expirm ' - _ _ 05-26-21-0080-00600-0260 Pasco County Property Appraiser Page 1 of 1 Data Current as Of: Weekly Archive - Saturday, March 17, 2018 Parcel ID 05-26-21-0080-00600-0260 (Card: 001 of 001) Classification 00 - Vacant Residential Mailing Address Property Value DUNE FL LAND I SUB LLC Ag Land $0 C/O HAWK MANAGEMENT CO LLC Land $26,770 2502 N ROCKY POINT DR STE 1050 Building $0 ROCKY POINT FL 33607-5995 Extra Features $0 Physical Address 6557 WAGON TRAIL STREET ZEPHYRHILLS, FL 33541 3ust Value $26,770 Assessed (Non-School Amendment 1) $26,770 Legal Description (First 4 Lines) SILVERADO RANCH SUBDIVISION PHASES 6, 8 &9A PB 75 PG 075 Taxable Value $26,770 BLOCK 6 LOT 26 jurisdiction City of Zephyrhills v Land Detail (Card: 001 of 001) Line Use _ DescriptionZoning Units ' Type jPrice Condition jUalue _ 1 0100 SFR MPUD 6,000.00 SF $4.00 1.00 $24,000 2 0100 SFR MPUD 6,925.00 SF $0.40 1.00 $2,770 _ Additional Land Information Acres 0.30 Tax Area 30SI FEMA Residential Code SLVRLPI � i Code I Building Information - Use 00 - Unimproved (Card: 001 of 001) Unimproved Parcel 00 - Unimproved Extra Features (Card: 001 of 001) Line IDescription Year _ Units Value No Extra Features Sales History- See All 5 sales Previous Owner: Month/Year Book/PageT p A DOR Code Condition Amount 05/2017 `9535 / 0546 Certificate of Title 05 Vacant Multi-Parcel Sale 11/2016 ,9� 462 / 0384 Mineral Rights or Royalty Transfer 05 Vacant Multi-Parcel Sale 04/2016 19364 / 0688 iMineral Rights or Royalty Transfer) 05 Vacant Multi-Parcel Sale http://search.pascopa.com/parcel.aspx?parcel=2126050080006000260 3/20/2018 . PASCO COUNTY, FLORIDA Permit No. 1 Jc58 7 Date Permitted Builder Name/Owner Name s! ) aG Control#' . County Parcel No. SubDiv: Z5► i'tjvdv Address/Location JJ 7 (it�R b�`� 1AA �T Classification/Type of Use TRANSPORTATION IMPACT FEE •. Rate: Sq.Ft Unit: b�s !, Exempt ❑Yes ❑ No How Determined Impact Fee Amount $=S b�Z• Zane No. TAZ: SCHOOL IMPACT FEE �f Account (056) Single-Family Detached House Amount $ � 7�•2 (057) Mobile Home (058) Other Residential 123) Collection Fee Exempt [ Yes ❑No How Determined PARKS AND RECREATION FEE Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation Total Zone TOTAL AMOUNT $ 76 �6 Exempt ❑Yes ❑ No How Determined LIBRARY FEE' Land Account land Credit Land Total Facility Account Facility Credit Facility Total Exempt ❑Yes ❑ No How Determined Total Amount RESOURCE FEE ERU TOTAL AMOUNT Prepared By Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY Acknowledgement below does not Imply acceptance of concurrence,but simply receipt of a copy of this form,placing . the building permit owner on notice of this assessment and the conditions of payment for same. DATE RECEIVED BY RECEIPT NO: DATE BY 05-26-21-0080-00600-0260 Pasco County Property Appraiser Page 1 of 1 Data Current as Of: Weekly Archive - Monday, April 16, 2018 Parcel ID 05-26-21-0080-00600-0260 (Card: 001 of 001) Classification 00 - Vacant Residential Mailing Address Property Value DR HORTON INC Ag Land $0 12602 TELECOM DR Land $26,770 TEMPLE TERRACE FL 33637-0935 Building $0 Physical Address , Extra Features $0 6557 WAGON TRAIL STREET ZEPHYRHILLS, FL 33541 Just Value $26,770 Legal Description (First 4 Lines) Assessed (Non-School Amendment 1) $26,770 See Plat for'this Subdivision Taxable Value $26,770 SILVERADO RANCH SUBDIVISION PHASES 6, 8 &9A PB 75 PG 075 BLOCK 6 LOT 26 Jurisdiction City of Zephyrhills Land Detail (Card: 001 of 001) _ Line_ Use_ DescriptionZoningUnits _ Type !Price Condition Value 1— I� 0100 '_SFR I _MPUD 6,000.00 SF $4.00 1.00 $24,000 - 2 -- 0100 _ SFRM I MPUD �6,925.00 SF $0.40 j 1.00 $2,770 _ Additional Land_ Information Acres i 0.30 Tax Area, 30SI { Code I I Residential Code SLVRLPI Building Information - Use 00 - Unimproved (Card: 001 of 001) Unimproved Parcel 00 - Unimproved Extra Features (Card: 001 of 001) Line __ Description —Y� earl _Units _ 'Value No Extra Features Sales History- See All 6 sales Previous Owner: DUNE FL LAND I SUB LLC Month/Year Book/Page . jT p DO C ConditionAmount 04/2018 9708 / 1472 Warranty Deed 05 Vacant Multi-Parcel Sale 05/2017 19535 / 0546 Certificate of Title 05 - _Vacant Multi-Parcel Sale 11/2016 462�9 / 0384 {Mineral Rights or Royalty Transfer] 05 Vacant Multi-Parcel Sale http://search.pascopa.com/parcel.aspx?parcel=2126050080006000260 4/19/2018 FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Hayden 2605 Elev C Builder Name: HE Street: Permit Office: City,State,Zip: Z L S35t_� Permit Number: fit Owner: Jurisdiction: tZ Design Location'. FL,Tampa County:: Pasco(Florida Climate Zone 2). 1. New construction or existing New(From Plans) 9. Wall Types(2614.2 scift.) Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1285.30 ft2 b.Concrete Block-Int Insul, Exterior R=4.1 996.67 ft2 3. Number of units,if multiple family I c.Frame-Wood,Adjacent R=1 1.0 332.22 ft2 4. Number of Bedrooms 5 d.N/A R= ft2 10.Ceiling Types (1541.0 sqft.) Insulation Area 5. Is this a worst case? No a.Under Attic(Vented) R=30.0 1541.00 ft2 6. Conditioned floor area above grade(W) 2605 b.N/A R= ft2 Conditioned floor area below grade(W) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(250.0 scift.) Description Area a.Sup:Attic, Ret:2nd Floor,AH:2nd Floor 6 261 a. U-Factor: Dbl,U=0.34 210.00 ft2 SHGC: SHGC=0.31 12.Cooling systems kBtu/hr Efficiency b. U-Factor: Dbl,U=0.55 40.00 ft2 SHGC: SHGC=0.34 a.Central Unit 40.0 SEER:14.00 c. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 41.0 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 1.052 ft. Area Weighted Average SHGC: 0.315 14.Hot water systems a.Electric Cap:50 gallons 8. Floor Types (1541.0 scift.) Insulation Area EF:0.950 a.Slab-On-Grade Edge Insulation R=O.O 1104.00 ft2 b. Conservation features b. Raised Floor R=19.0 437.00 ft2 None c.N/A R= 1 ft2 15.Credits Pstat Glass/Floor Area: 0.096 Total Proposed Modified Loads: 79.42 PASS Total Baseline Loads: 79.15 I hereby certify that the plans and specifications covered by Review of the plans and ST_ this calculation are in compliance with the Florida Energy specifications covered by this 0 ffs Code. calculation indicates compliance =�;9z 4: with the Florida Energy Code. PREPARED BY: Before construction is completed W DATE: this building will be inspected for 0 -7. compliance with Section 553.9108 .. ......... I hereby certify that this building,as designed,is in compliance Florida Statutes. with the Florida Energy Co elr- SOD WE OWNER/AGENT- BUILDING OFFICIAL: DATE: DATE: Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1-2. - Compliance with a proposed duct leakage Qp requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with Section 803 of RESINET Standards,is not greater than 0.060 Qn for whole house. 11/11/2017 12:48 PM EnergyGaugeg USA-FIaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: ayden 2605 Elev C Builder Name: DRH Express Homes Street: S �� `� Permit Office: City,State,Zip: Zephyrh'li s, FL,S35" Permit Number: Owner: � Jurisdiction: Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(2614.2 sgft.) Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood, Exterior R=11.0 1285.30 ft2 b.Concrete Block-Int Insul,Exterior R=4.1 996.67 ft2 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 332.22 ft2 4. Number of Bedrooms 5 d.N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types (1541.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1541.00 ft2 6. Conditioned floor area above grade(ft2) 2605 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(250.0 sqft) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 261 a. U-Factor: Dbl,U=0.34 210.00 ft2 SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.55 40.00 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.34 a.Central Unit 40.0 SEER:14.00 c. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 41.0 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 1.052 ft. Area Weighted Average SHGC: 0.315 14.Hot water systems 8. Floor Types (1541.0 sqft.) Insulation Area a. Electric Cap:50 gallons EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1104.00 ft2 b. Conservation features b,Raised Floor R=19.0 437.00 ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.096 Total Proposed Modified Loads:. 79.42 PASS Total Baseline Loads: 79.15 I hereby certify that the plans and specifications covered by Review of the plans and SE Spq?� this calculation are in compliance with the Florida Energy specifications covered by this eg_ Off, Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: dJ`�` ,�,;.. Before construction is completed .. .1 d DATE: n-u-n this building will be inspected for compliance with Section 553.908 * �, I hereby certify that this building,as designed,is in compliance Florida Statutes. with the Florida Energy Cow-� ©D WE. OWNER/AGENT: C/�� BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. - Compliance with a proposed duct leakage On requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with Section 803 of RESNET Standards, is not greater than 0.060 On for whole house. 11/11/2017 12:48 PM EnergyGauge@ USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2014 PROJECT Title: Hayden 2605 Elev C Bedrooms: 5 Address Type: Lot Information Building Type: User Conditioned Area: 2605 Lot# 26/6 Owner: Total Stories: 2 Blcck/SubDivision: Silverado Ranch #of Units: 1 Worst Case: No PlatBook: Builder Name: DRH Express Homes Rotate Angle: 45 Street: Permit Office: Cross Ventilation: County: Pasco Jurisdiction: Whole House Fan: City,State,Zip: Zephyrhills, Family Type: Single-family FL, New/Existing: New(From Plans) Comment: Garage R Face NE CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp , V Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Tampa FL_TAMPA_INTERNATI 2 39 91 70 75 645.5 54 Medium BLOCKS Number Name Area Volume 1 Blocks 2605 21579.7 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1104 9571.7 Yes 1 1 1 Yes Yes Yes 2 2nd Floor 1501 12008 No 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio Main 152.8 ft 0 1104 ftz ---- 0.2 0 0.8 2 Raised Floor 2nd Floor ---- ---- 437 ftz 19 0.5 0 0.5 ROOF. / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1723 ftz 0 ftz Dark 0.92 No 0.9 No 0 26.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 1541 ft2 Y N 11/11/2017 12:48 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2014 CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) Main 30 Blown 40 ft2 0.11 Wood 2 Under Attic(Vented) 2nd Floor 30 Blown 1501 ft2 0.11 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 N=>NE Exterior Concrete Block-Int Insul Main 4.1 18 8 8 8 161.8 ft2 0 0.6 0 2 W=>NW Exterior Concrete Block-Int Insul Main 4.1 20 8 8 173.3.ft2 0 0.6 0 3 S=>SW Exterior Concrete Block-Int Insul Main 4.1 39 8 8 8 343.8 ft2 0 0.6 0 4 E=>SE Exterior Concrete Block-Int Insul Main 4.1 36 8 8 8 317.8 ft2 0 0.6 0 5 N=>NE Garage Frame-Wood Main 11 20 4 8 8 176.2 ft2 0.23 0.01 0 6 W=>NW Garage Frame-Wood Main 11 18 0 8 8 156.0 ft2 0.23 0.01 0 7 N=>NE Exterior Frame-Wood 2nd Floor 11 39 8 8 317.3 ft2 0.23 0.6 0 j 8 W=>NW Exterior Frame-Wood 2nd Floor 11 40 8 8 325.3 ft2 0.23 0.6 0 9 S=>SW Exterior Frame-Wood 2nd Floor 11 39 8 8 317.3 ft2 0.23 0.6 0 10 E=>SE Exterior Frame-Wood 2nd Floor 11 40 8 8 325.3 ft2 0.23 0.6 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N=>NE Insulated Main None .4 3 6 8 20 ft2 2 N=>NE Wood Main None .46 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered orientation => changed to As Built rotated 45 degrees). Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N=>NE 1 Vinyl Low-E Double Yes 0.34 0.31 31.0 ft2 1 ft 0 in 10 ft 0 in Drapes/blinds None 2 N=>NE 1 Vinyl Low-E Double Yes 0.34 0.31 2.5 ft2 6 ft 2 in 0 ft 0 in Drapes/blinds None 3 S=>SW 3 Vinyl Low-E Double Yes 0.34 0.31 46.5 ft2 1 ft 0 in 10 ft 6 in Drapes/blinds None 4 S=>SW 3 Metal Low-E Double Yes 0.55 0.34 40.0 ft2 1 ft 0 in 1 ft 3 in Drapes/blinds None 5 N=>NE 7 Vinyl Low-E Double Yes _ 0.34 0.31 6.0 ft2 1 ft 0 in 0 ft 6 in Drapes/blinds None 6 N=>NE 7 Vinyl Low-E Double Yes 0.34 0.31 31.0 ft2 1 ft 0 in 2 ft 6 in Drapes/blinds None 7 . S=>SW 9 Vinyl Low-E Double Yes 0.34 0.31 62.0 ft2 1 ft 0 in 0 ft 6 in Drapes/blinds None 8 N=>NE 7 Vinyl Low-E Double Yes 0.34 0.31 31.0 ft2 1 ft 0 in 0 ft 6 in Drapes/blinds None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 437.038 ft2 437.038 ft2 48.4 ft 8.67 ft 0 I I 11/11/2017 12:48 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2014 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000368 2517.6 138.21 259.93 .3402 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump None HSPF:8.2 41 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit None SEER:14 40 kBtu/hr 1200 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 50 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS / ----Supply---- ----Return---- Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 261 ft2 2nd Floor 45 ft2 Proposed Qn 2nd Floor ---cfm 156.3 cfm 0.06 0.60 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Coolingr Jan r Feb Mar r Apr May rX�Jun Jul rX�AugrX�Se [ ]Oct r 1 Nov rr Dec Heatin �X}Jan [X}Feb Mar []Ar l May [ ]Jun L Jul [ ]Au [ ]Sep [_]Oct Nov [X Dec Venting [[[ 1 Jan [[[ ]Feb X Mar [[[XXX]]]Apr l ]]]May [[[ ]Jun l Jul [[[ ]Aug [[[ ]Se [X]Oct [[[[XXXX]]]]Nov [[[[[[ III]]]Dec 11/11/2017 12:48 PM EnergyGauge@ USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-20.14 Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 '78 78•- 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 •68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 ..68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 1 1/1 1/2017 12:48 PM EnergyGaugeg USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5 FORM R405.2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerformance Index,the more efficient the home. Zephyrhills, FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Frame-Wood, Exterior R=11.0 1285.30 ft2 b.Concrete Block-Int Insul, Exterior R=4.1 996.67 ft2 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 332.22 ft2 4. Number of Bedrooms 5 d.N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types Insulation Area a.Under Attic(Vented) R=30.0 1541.00 ft2 6. Conditioned floor area(ft2) 2605 b.N/A R= ft2 7. Windows" Description Area c.N/A R= ft2 a. U-Factor: Dbl,U=0.34 210.00 ft2 11. Ducts R ft2 SHGC: SHGC=0.31 a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 261 b. U-Factor: Dbl,U=0.55 40.00 ft2 SHGC: SHGC=0.34 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a.Central Unit 40.0 SEER:14.00 SHGC: d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 41.0 HSPF:8.20 Area Weighted Average Overhang Depth: 1.052 ft. Area Weighted Average SHGC: 0.315 8. Floor Types Insulation Area 14.Hot water systems a. Electric Cap:50 gallons a.Slab-On-Grade Edge Insulation R=0.0 1104.00 ft2 EF:0.95 b.Raised Floor R=19.0 437.00 ft2 c.N/A R= ft2 b. Conservation features None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building E Sr Construction through the above energy saving features which will be installed (or exceeded) tiofH AT�o in this home before final inspection. Otherwise, a new EPL Display Card will be completed � `,,,;''��i' •s' based on installed Code compliant features. Builder Signature: Date: will Address of New Home. (0 S53: _ (1nMTn r I _C+ City/FL Zip: , r L- *�•G�D `Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient . mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 11/11/2017 12:49 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 Florida Department of Business and Professional Regulations Residential Whole Building Performance and Prescriptive Methods ADDRESS: Permit Number: Zephyrhills,FL, MANDATORY REQUIREMENTS See individual code sections for full details. 401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy..Florida law (Section 553.9085,Florida Statues]requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix C. R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.1 through R402.4.4. Q R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.The sealing methods between dissimilar materials shall allow for differential expansion and contraction. • R402.4.1.1 Installation. The components of the building.thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table 402.4.1.1,as applicable to the method of construction. Where required by the code official,an approved third party shall inspect all components and verify compliance. • R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2,and 3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3.Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. O R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers and outdoor combustion air. O R402.4.3 Fenestration air leakage.Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400 or AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. O R402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential.All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. R403.2.2 Sealing(Mandatory)AII ducts,air handlers,and filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance with Section C403.2.7.2 of the Commercial Provisions of this.code and shall be shown to meet duct tightness criteria by post-construction or rough-in testing below. Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either an energy rater certified in accordance with Section 553.99, Florida Statutes,or as authorized by Florida Statutes,to be"substantially leak free"by either of the following: 1. Post-construction test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure.All register boots shall be taped or otherwise sealed during the test. 2. Rough-in test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25Pa)across the system,including the manufacturer's air handler enclosure.All registers shall be taped or otherwise sealed during the test.If the air handler is not installed at the time of the test,total leakage shall be less than or equal to 3 cfm (85 Umin)per 100 square feet(9.29 m2)of conditioned floor area. Exceptions: 1. The total leakage test is not required for ducts and air handlers located entirely within the building envelope. 2. Duct testing is not mandatory for buildings complying by Section R405 of this code. 11/11/2017 12:49 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Com Page 1 of 3 FORM R405.2014 MANDATORY REQUIREMENTS - (Continued) ❑ R403.2.3 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. ❑ R403.3 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C) or below 550F(13°C)shall be insulated to a minimum of-R-3., R403.3.1 Protection of piping insulation. ❑ R403.4.1 Circulating hot water systems(Mandatory). Circulating hot water systems shall be provided with an automatic or readily accessible manual switch that can turn off the hot-water circulating pump when the system is not in use. ❑ R403.4.3 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3 1/2 inches(89 mm)in the hot water distribution line and cold water line located as close as possible to the storage tank. ❑ R403.4.4 Water heater efficiencies(Mandatory). 0 R403.4.4.1 Storage water heater temperature controls • R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature setting range shall be from 1001F to 140°F(38°C to 60°C). • R403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s) of combustion types of service water heating systems to be turned off. 0 R403.4.4.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation,Commercial Provisions,for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water heating category. Solar water heaters shall met the criteria Section 11403.4.4.2.1. R403.4.4.2.1 Solar water heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors, and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol,Collectors in installed solar water heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and 2. Be installed at an orientation within 45 degrees of true south. ❑ R403.5 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code, Residential or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. ❑ R403.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment. 0 R403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1.This code does not allow designer safety factors,provisions for future expansion or other factors which affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. • R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load,but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.6,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load. 1 1/1 1/2017 12:49 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Com Page 2 of 3 FORM R405:2014 MANDATORY REQUIREMENTS - (Continued) O R403.6.1.1 Cooling equipment capacity.(continued) The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacture's expanded performance data shall be used to select cooling-only equipment.This selection shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower cfm provided by the expanded performance data, the design value for entering wet bulb temperature and the design value for entering dry bulb temperature. Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space. Exceptions: 1. Attached single-and multi-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida-registered engineer,in attached single-and multi-family units,the capacity of equipment may be sized in accordance with good_design practice. O R403.6.1.2 Heating equipment capacity • R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section R403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load. • R403.6.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.6.1. • R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.6.1. O R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. ❑ R403.7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the Commercial Provisions in lieu of Section R403. ❑ R403.8 Snow melt system controls(Mandatory). Snow and ice-melting systems,supplied through energy service to the building,shall include automatic controls capable of shutting off the system when the pavement temperature is above 55°F,and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F. ❑ R403.9 Swimming pools,inground spas and portable spas(Mandatory). The energy requirements for residential pools and inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSI/APSP-15.The energy requirements for portable spas shall be in accordance with ANSI/APSP-14. O R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on-off switch that is mounted outside the heater to allow shutting off the heater without adjusting the thermostat setting. R403.9.1.1 Gas and oil-fired pool and spa heaters. All gas-and oil-fired pool and space heaters shall have a minimum thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013 when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights. R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. O R403.9.2 Time switches. Time switches or other control method that can automatically turn off and on heaters and pumps according to a preset schedule shall be installed on all heaters and pumps.Heaters,pumps and motors that have built in timers shall be deemed in compliance with this equipment. Exceptions: • 1. Where public health standards require 24-hour pump operations. 2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation. O R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Outdoor pools deriving over 70 percent of the energy for heating from site-recovered energy,such as a heat pump or solar energy source computed over an operating season. ❑ RR404.1 Lighting equipment(Mandatory). A minimum of 75 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps. Exception: Low-voltage lighting shall not be required to utilize high-efficacy lamps. O R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights ❑ R405.2 Performance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R-6. O R405.2.1 Performance ONLY. Ceilings shall have minimum insulation of R-19.Where single assemby of the exposed deck and beam type or . concrete deck roofs do not have sufficent space, R-10 is allowed. 11/11/2017 12:49 PM EnergyGauge@ USA-FlaRes2014 -Section R405.4.1 Com Page 3 of 3 FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Hayden 2605-Elev C Builder Name: DRH Express Homes Street: Permit Office: City,State,Zip: Zephyrhills, FL, Permit Number: - Owner: Jurisdiction: Design Location: FL,Tampa COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge'of insulation. Crawl space walls Where provided in lieu of floor insulation,insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations,and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit,or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated,and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 11/11/2017 12:49 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION_ Envelope Leakage Test Report Prescriptive and Performance Method Project Name: Hayden 2605 Elev C Builder Name: DRH Express Homes Street: Permit Office: City,State,Zip: Zephyrhills,FL, Permit Number: Design Location: FL,Tampa Jurisdiction: Cond. Floor Area:: 2605 sq.ft. Cond.Volume: 21580 cu ft. Envelope Leakage Test Results Leakage Characteristics Regression Data: C: n: R: .CFM(50): Single or Multi Point Test Data HOUSE PRESSURE FLOW: ELA' 1 Pa cfm EgLA: 2 Pa cfm ACH: 3 Pa cfm ACH(50): 4 Pa cfm 5 Pa cfm SLA: 6 Pa cfm R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2,3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdraft'and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3.Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. I hereby certify that the above envelope leakage Where required by the code official, OfZ1B7- A�t� performance results demonstrate compliance testing shall be conducted by an O,f, with Florida Energy Code requirements in approved third party. A written accordance with Section R402.4.1.2. report of the results of the test shall be signed by the third party .". 1 , _ v 141 •a conducting the test and provided to ' n SIGNATURE: the code official. r,�cQfl �v5� PRINTED NAME: WB DATE: BUILDING OFFICIAL: DATE: 11/11/2017 12:49 PM EnergyGauge®USA-FlaRes2014. -Section R405.4.1 Compliant Software Page 1 of 1 FORM R465-2014 Duct Leakage Test Report Performance Method FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Form R405 Duct Leakage Test Report Performance Method Project Name: Hayden 2605 Elev C Builder Name: DRH Express Homes . Street: Permit Office: City,State,Zip: Zephyrhills, FL, Permit Number: Design Location: FL,Tampa Jurisdiction: Duct Test Time: Post Construction Duct Leakage Test Results CFM25 Duct Leakage Test Values Line System Outside Duct Leakage 1 System 1 cfm25(Out) 2 System 2 cfm25(Out) 3 System 3 cfm25(Out) 4 System 4 cfm25(Out) 5 Total House Sum lines 1-4 Duct System Leakage Divide by (Total Conditioned Floor Area) (Qn,Out) certify the tested duct leakage to outside, Qn, is not greater than the proposed duct leakage Qn Duct tightness shall be verified by O�'VftE So specified on Form R405-2014. testing to Section 803 of the RESNET ,,,, K_ Standards by an energy rater certified in accordance with Section 553.99, Florida Statutes. ,. SIGNATURE: PRINTED NAME: Ofl WIE�� DATE: BUILDING OFFICIAL: DATE: 11/11/2017 12:49 PM EnergyGauge@ USA-FlaRes2014 -Section R405.4.1 Compliant S Page 1 of 1 Manual S Compliance Report Job: " Wr19htSOft� p P Date: Oct 10,2014 Entire House By- Progressive Air Systems, Inc 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 Project • • For: DR Horton/Express Lot 26 Blk_6 Silverado Ranch, Zephyrhills, FL Cooling Equipment Design Conditions Outdoor design DB: 91.2°F Sensible gain: 30501 Btuh Entering coil DB: 76.4°F Outdoor design WB: 77.1 OF Latent gain: 4144 Btuh Entering coil WB: 63.2°F Indoor design DB: 75.0°F Total gain: 34645 Btuh Indoor RH: 50% Estimated airflow: 1367 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB042****A+FB4CNP042 Actual airflow: 1367 cfm Sensible capacity: 32445 Btuh 106%of load Latent capacity: 6269 Btuh 151%of load Total capacity: 38714. Btuh 1120%of load SHR: 84% Heating Equipment. Design Conditions Outdoor design DB: 40.0°F Heat loss: 27149 Btuh Entering coil DB: 69.5°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB042****A+FB4CNP042 Actual airflow: 1367 cfm Output capacity: 37299 Btuh 137%of load Capacity balance: 31 OF Supplemental heat required: 0 Btuh Economic balance: -99 OF i Backup equipment type: , Elec strip Manufacturer: Model: Actual airflow: 1367 cfm Output capacity: 8.6 kW 108%of load Temp. rise: 18 OF Meets are all requirements of ACCA Manual S. wri htsofts 2017-Nov-1112:50:05 9 Right-Suite®Universal 2017 17.0.21 RSU25554 Page 1 ACCk ..\Wrightsoft Files\Express homes\Hayden-4EHB.rup Calc=MA House faces:NE Load Short Form Job: + wrightsofto Date: Oct 10,2014 Entire House By: Progressive Air Systems, Inc 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 Project Information For: DR Horton/Express Lot 26 Blk 6 Silverado Ranch, Zephyrhills, FL Design Inf• • Htg Clg Infiltration Outside db(OF) 40 91 Method Simplified Inside db(OF) 70 75 Construction quality Semi-tight Design TD (OF) 30 16 Fireplaces 0 Daily range - L Inside humidity (%) 50 50 Moisture difference(gr/lb) 26 54 HEATING EQUIPMENT COOLING EQUIPMENT Make Carrier Make Carrier Trade CARRIER Trade CARRIER Model CH14NB042****A Cond CH14NB042****A AHRI ref Coil FB4CNP042 AHRI ref - Efficiency 8 HSPF Efficiency 11.3 EER, 13.7 SEER Heating input Sensible cooling 30750 Btuh Heating output 38500 Btuh @ 47OF Latent cooling 10250 Btuh Temperature rise 26 OF Total cooling 41000 Btuh Actual air flow 1367 cfm Actual air flow 1367 cfm Air flow factor 0.050 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 0.56 in H2O Static pressure 0.56 in H2O Space thermostat Load sensible heat ratio 0.88 Capacity balance point=31 OF Backup: Input=9 kW, Output=29290 Btuh, 100 AFUE ROOM NAME - Area Htg load - Clg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) kitchen/living 608 7370 8809 371 395 bed 2 164 2960 2019 149 90 powder 59 968 394 49 18 flex 156 3106 2422 156 109 foyer 75 1443 954 73 43 stairs 44 0 0 0 0 bed4 181 1647 2220 83 100 bed3 184 1965 2606 99 117 wic 60 143 190 7 9 wic 2 32 706 722 36 32 m suite 277 2507 3364 126 151 bath 135 355 380 18 17 upstairs living 234 1366 2665 69 119 stairs 2 50- 0 0 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -ELrF wrli htsoft` 2o17-Nov-11 12: ge 1 Right-Suite(al Universal 2017 17.0.21 RSU25554 Page 1 ACCK ...\Wrightsofl Files\Express homes\Hayden-4EHB.rup Calc=MJ8 House faces:NE ted5 175 1606 2174 81 97 laundry 41 368 983 19, 44 a/c 19 0 0 0 0 bath 3 96 639 599 32 27 hall 63 0 0 0 0 Entire House d 2651. 27149 30501 1367 1367 Other equip loads 0 0 Equip. @ 1.00 RSM 30501 Latent cooling -4144 TOTALS 2651 27149 34645 1367 1367 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. i htSoft' 2017-Nov-1112:50:05 wr �." 9 Right-Suite®Universal 2017 17.0.21 RSU25554 Page 2 ADM ...\Wrightsoit Files\E)press homes\Hayden-4EHB.rup Calc=MJ8 House faces:NE 9 Project Summary Job: wri' htsoft Entire House Y Byte: Oct 10,2014 Progressive Air Systems, Inc 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 Proapet Information For: DR Horton/Exppress Lot 26 Blk 6 Silverado Ranch, Zephyrhills, FL Notes: Design Information Weather: Tampa Intl AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 40 OF Outside db 91 OF Inside db 70 OF Inside db 75 OF Design TD 30 OF Design TD 16 OF Daily range L Relative humidity 50 % Moisture difference 54 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 20520 Btuh Structure 21513 Btuh Ducts 6629 Btuh Ducts 8988 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 27149 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 30501 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 2674 Btuh Ducts 1469 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling (none) Area(ft2 2651 2651 Equipment latent load 4144 Btuh Volume(ft3) 22094 22094 Air changes/hour 0.22 0.11 Equipment total load 34645 Btuh Equiv.AVF(cfm) 81 41 Req. total capacity at 0.75 SHR 3.4 ton Heating Equipment Summary. Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER Trade CARRIER Model CH14NB042****A Cond CH14NB042****A AHRI ref Coil FB4CNP042 AHRI ref Efficiency 8 HSPF Efficiency 11.3 EER, 13.7 SEER Heating input Sensible cooling 30750 Btuh Heating output 38500 Btuh @ 47OF Latent cooling 10250 Btuh Temperature rise 26 OF - Total cooling 41000 Btuh Actual air flow 1367 cfm Actual air flow 1367 cfm Air flow factor 0.050 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 0.56 in H2O Static pressure 0.56 in H2O Space thermostat Load sensible heat ratio 0.88 Capacity balance point=31 OF Backup: Input=9 kW, Output=29290 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Wrl9 htsoft" 2017-Nov-1112:50:05 Right-Suite®Universal 2017 17.0.21 RSU25554 Page 1 ...\Wrightsoft Files\Express homes\Hayden-4EHB.rup Calc=MJ8 House faces:NE FQRM R405-2014 RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST Florida Department of Business and Professional Regulation Simulated Performance Alternative(Performance)Method Applications for compliance with the 2014 Florida Building Code, Energy Conservation via the . residential Simulated Performance method shall include i ❑ This checklist ❑ A Form R405 report that documents that the Proposed Design complies with Section R405.3 of the Florida Energy Code. This form shall include a summary page indicating home address, a-ratio and the pass or fail status along with summary areas and types of components, whether the home was simulated as a worst-case orientation, name and version of the compliance software tool, name of individual completing the compliance report(1 page)and an input summary checklist that can be used for field verification(usually 4 pages/may be greater). ❑ Energy Performance Level(EPL) Display Card(one page) ❑ Mandatory Requirements(three pages) Required prior to CO for the Performance Method: ❑ Air Barrier and Insulation Inspection Component Criteria checklist(Table R402.4.1.1 - one page) ❑ A completed Envelope Leakage Test Report(usually one page) ❑ If Form R405 duct leakage type indicates anything other than "default leakage", then a completed Form R405 Duct Leakage Test Report(usually one page) i EnergyGauge®-USRCZB v5.1 1 1/1 1/2017 1:09:55 PM Page 1 of 1 CITY OF " NOTICE / / BUILDING ZEPHYRHILLS DEPARTMENT OF ADDITION OR CORRECTION D • -NOT - • ADDRESS DATE PERMIT C SSA -r ? THIS JOB HAS NOT BEEN COMPLETED. The following additions or corrections shall be made before the job will be accepted. It is unlawful for any Carpenter,Contractor,Builder,or other persons,to AFTER CORRECTIONS ARE MADE CALL cover or cause to be covered,any part of the work with flooring,lath,earth 780-0020 FOR RE-INSPECTION or other material,until the proper inspector has had ample time to approve the installation. OFFICE HOURS 7:30AM-4:30 PM MON.-FRI. INSPECTOR t" CITY OF " NOTICE / / BUILDING ZEPHYRHILLS DEPARTMENT OF ADDITION OR CORRECTION DO :,NO.T REMOVE ADDRESS LW �A� AT �ir� PERMIT�5„(Sys':1l THIS JOB HAS NOT BEEN COMPLETED. The following additions or corrections shall be made before the job will be accepted. o --ro e, 0 I (,b o n ELI U It is unlawful for any Carpenter,Contractor,Builder,or other persons,to AFTER CORRECTIONS ARE MADE CALL cover or cause to be covered,any part of the work with flooring,lath,earth 780-0�2� R E-INSPECTION or other material,until the proper Inspector has had ample time to approve the installation. OFFICE HOURS 7:30AM-4:30 PM MON.-FRI. INSPECTOR FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Envelope Leakage Test Report Prescriptive and Performance Method Project Name: SILVERADO Builder Name: D R HORTON Street: 6557 Wagon Trail St Permit Office: City,State,Zip: Zephyrhills,FL 33541 Permit Number: Design Location: 6557 Wagon Trail St(Lot 26) Jurisdiction: Cond.Floor Area: 2613 Cond.Volume: 22024 Envelope Leakage Test Results Leakage Characteristics Regression Data: C: n: R: CFM(50): 1875 Single or Multi Point Test Data ELA: 103 HOUSE PRESSURE FLOW: 1 50 Pa 1875 cfm EgLA: 244 . 2 0 Pa 0 cfm ACH: 5.11 SLA: .04 3 0 Pa 0 cfm 4 0 Pa 0 cfm ACH(50)': 5.11 For prescriptive projects,tested leakage must be<=7 5 0 Pa 0 cfm ACH(50). For performance projects, tested leakage must be<=the ACH(50)shown on Form R405-2014 6 Pa cfm for this project. R402.4.1.2 Testing.The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zones 1 and 2.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statutes or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration 3.Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. I hereby certify that the above envelope leakage performance results demonstrate compliance with Florida Energy Code requirements in accordance with Section R402.4.1.2. Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7), Florida Statutes 01, aESr42� or individuals licensed as set forth in Section �AV•>„ _ G� 489.105(3)(9,(g),or(i)or an approved third party.A written report of the results of the test shall be signed 1% - Digitally signed by Michael by the third party conducting the test and provided to --�lil( Silberstein the code official. Date:2018.08.1514:35:42 EDT CN=Michael Silberstein,O=TopBuild Home Services,OU, we EMAILADDRES S=Mich ael.Silberste i Signature: n@topbuild.com,C=US Printed Name: Michael Silberstein BUILDING OFFICIA Date: 08/15/2018 DATE: Thank you for allowing TopBuild the opportunity to provide the above services for you.Please feel free to contact me with any questions. 10/25/2017 391903 PASCO COUNTY ` DEVELOPMENT SERVICES PAS.0 �„ 8731 Citizens Drive Date:7/10/2018 CouN�rSr...FLonrD New Port Richey,FL 34654 f)mN`RACES.G1BAA•r 1'Incr�. 727-847-2411 ........... .... . Receipt#: 1774490 FEE DESCRIPTION ACCOUNT CODE UNITS INVOICE# FEE AMOUNT PAID RECEIPT# DATE Impact Fee Residential Solid 24603100-329010 31.60 1362314 $31.60 $31.60 1774490 7/10/18 Waste Single Family TOTALS: $31.60 $31.60 Receipt Paid By Check# CC Auth# Cashier ID Workstation Receipt Date Amt Paid 1774490 Check 767924 540 BCCCP06W 0711 0/2 01 8 $31.60 Total Payments: $31.60 Pa or Address Phone D R Horton 1341 Horton Circle Arlington TX 76011 Comments: City of Zephyrhills Sol! aste7-4-," Address:'655 g n-Trail Street Parcel:05 26 210080 00600 0260 While you will be paying your bill with Pasco County Development services,the full amount of the credit card or a-check fees,NOT shown above,Is collected by First Billing payment services. MyReports/reports//PASCOPROD/PASC0/ReceiptP05_V6.rpt 7/10/2018 Page 1 of 1 This home has been professionally insulated with Owens Corning PROPINK@ L77 Loosefill Insulation Name Address 151 7 (41,19011 71 ra i MY State FL zip Owens Corning 0 PROPINKO L77 Loosefill Insulation Owens Coming Insulating Systems,LLC will accept no responsibility when the product is not Installed in accordance with the product label.Stated R-value is provided by installing the required number of bags at a thickness not less than the labeled minimum thickness.Installation of the required number of bags may yield more than the specified minimum thickness.Failure by the installer to provide both the required bags and at least the minimum thickness will result in lower insulation R-value. Specification for Open Attics Coverage charts are based on a nominal net bag Blow Attics Minimum Maximum Minimum weight of 32lbs. Initial Minimum Coverage Minimum Weight New Construction�:30 Installed Settled Per Bag Bags Per (ibs per Walls 'Retrofit R-value Thickness Thickness* (sq.fQ 1000 sq.fL sq.ft.) Number of bags used (inches) Minimum Estimated R-value of 13 4.75 4.75 184.6 5.4 0.173 Initial Installed Maximum Minimum Minimum previous insulation 19 7.00 7.00 125 8.0 0.256 Installed Density Coverage Bags Per Weight 22 8.00 8.00 - 1063 '9.4 0,301 Thickness Cbs.per Per Bag 1000 Cbs.per Area of coverage 26 9.25 9.25 89.6 11.2 0.357 '1`1- (sq.ft.)N5 i 30 10.50 10.50 77.0 13.0 0.416 value Framing (inches) cu.It.) (sq.fL) sq.ft. sq.ft.) Other type(s)of 1 38 13,25 13.25 59.5 16.7 0.534 14 2X4 3.5 1.25 87.8 11.4 0,364 insulation in attic " 1 15.00 15.00 50.7 191 0.631 15 2X4 3.5 1.45 75.7 13.2 0.423 Thickness of 12 12 16.75 45 22.2 --F71-1 16 2x4 3.5 2.20 49.920.1 0.642 insulation p 20.00 35.8 28.0 0.895 22 2x6 5.5 1.25 55.9 17.9 0.573 Depth of previous 23 2X6 5.6 1.35 51.7 19.3 0.619 insulation 24 2x6 5.5 1.75 40.0 25.0 0.802 Cathedral Ceiling Minimum Floors InstalledMaximum Minimum Minimum Minimum Initial Density Coverage Bags Per Weight Initial Installed Maximum Minimum Minimum R- Installed (lbs.per Per Bag 1000 sq. Cbs.per Installed Density Coverage Bags Per Weight value Framing Thickness . ass Cbs.per Cbs.per Cinches) cu.ft-) (sq.%) ft. sq.ft.) F- Framing Thickness ft Per 1000 30 2x8 7.25 1.35 39.2 25.5 0.316 value Cinches) cu. ) Bag(sq.ft.) sq.ft. sq* 38 2x1 0 9.25 1.35 30.8 32.5 1.041 j 30 2xe 7.25 1.35 39.2 25.5 0.841 49 2x12 11.25 1.85 18.5 54.2 1.734 1 38 2x10 9.25 1.35 30.8 322 1.041 46 2X12 1125 1.35 25.3 39.6 1266 Owens Coming(g)glass fiber blanket and loosefill thermal insulations,when installed per the manufacturers'coverage charts and recommendations,will provide the labeled R-Value. THE FOLLOWING PRODUCTS HAVE BEEN INSTALLED IN THIS HOUSE. Kraft Unfaced Foil Loosefill FS-25 R-value Thickness No.pkgs. Coverage Area Ceilings 13 13 13 13 13 13 El is 13 13 Floors 13 0 [3 13 E3 13 13 13 13 Walls E3 13 13 [3 0 13 E3 13 13 Basement 13 13 0 13 13 13 E3 [3 E3 13 Crawlspace E3 E3 13 13 13 [3 13 13 [3 13 Attic 13 0 13 13 13 13 to [3 13 Contractor Daniel Insulation Date Buildel Date Company Company (Signature) (Signature) Address 12950 Daniel Dr. Address Phone (727)572-8990 Phone.. OWENS CORNING INSULATING SYSTEMS,LLC ONE OWENS CORNING PARKWAY TOLEDO,OHIO,USA 43659 Pub.No.10DIO804-C.PtintedinU.S.A.October 2016.The color PINK is a registered trademark of Owens Coming.@2016 Owens Coming Insulating Systems,LLC.Al rights reserved. www.owenscorning.com r ` L � _i_ '��, . 'a''-`t i�. �j ,A t� y_.1�, +�1,yam..