Loading...
HomeMy WebLinkAbout18-19589 CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 . : 19589 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL = = PERMIT INFORMATION LOCATION INFORMATION Permit#:19589 Issued: 41 6/2018 Address: 6605 WAGON TRAIL ST Permit Type: NEW SINGLE FAMILY DWELLING - ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 347,525.25 Total Fees: 11,759.19 Subdivision: SILVERADO Amount Paid: 11,759.19 Date Paid: 4/26/2018 Parcel Number: 05-26-21-0080-00600-0320 CONTRACTOR INFORMATION OWNER INFORMATION Name: DR HORTON INC Name: DR HORTON INC Addr: 12602 TELECOM DR Address: 12602 TELECOM DR TAMPA, FL. 33637 TEMPLE TERRACE FL 33637-0935 Phone: Lic: Phone: 813-549-1968 Work Desc: CONSTRUCT.SINGLE FAMILY HOME 3,085 SQ FT APPLICATION FEES BUILDING FEE 1,336.64 ELECTRICAL FEE 277.20 PLUMBING F 184.80 MECHANICAL FEE 129.36 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE-sfr/100% 4,828.00 SCHOOL IMPACT FEE-sfr/1% 48.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32 � I Inspections Required F OTER 2ND RO GH P UMB Misc INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRACTORS SIGNATURE PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS.WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER ICU It i UH- iY 1Lf} City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: Date Received: Site: 0S r Permit Type: Approved w/no comments:O Approved w/the below comments: L Denied w/the below comments: O This comment sheet shall be kept with the permit and/or plans. j Kalvin Swi01- Plan ct Examiner Date Contraor and/or Homeowner (Required when comments are present) i i D. R. Horton-6605 Wagon Trail-3,085 sq ft Column SQ. FEET PRICE MAIN OR LIVING: 3,085 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 347,525.25 FEE SHEET $ 1,232.00 ADDRESS $ 40.00 DRIVEWAY1 $ 40.00 BUILDING: $ 1,336.64 ELECTRICAL: $ 277.20 PLUMBING: $ 184.80 MECHANICAL: $ 129.36 SUB-TOTAL $ 1,928.00 TOTAL $ 1,928.00 SEWER: n/a WATER: n/a IRRIGATION: $ - TOTAL: $ - WATER METER: n/a IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 2,481.35 PARK IMPACT FEES $ 769.56 SIF'S: $ 4,828.00 100.0% $ . 4,828.00 1.0% $ 48.28 TOTAL: $ 4,876.28 T 1 F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 11,759.19 INSTR#2018065736 OR BK 9711 PG 2336 Page 1 of 1 04/19/2018 10:59 AM Rcpt:1950023 Rec:10.00 DS:0.00 IT:0.00 Paula S.ONei�Ph.D.,Pasco County CCerk&ComytrolCer r° Permit No. Parcel ID No vGv�`''�y V �Z r-� / NOTICE OF COMMENCEMENT A �. State of F(prl t.lJ Q_ County of pas THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and In accordance with Chp713,Florida Statute, the following information Is provided In this Notice of Comma cement: 2� i 1/_ _ •r _ c1. Description of Prop rty: Parcel dentiftcation No. {^-J 11[/�(/�1.� IQ.7e Street Address: 2. General Description of Improvement SE' 3. Owner Information or Lessee Information if the Lessee contracted for the improvement: 17-6 O z N 4 �rr�M r vu ja o Address r I City r Stale Interest in Property., Name of Fee Simple Titleholder. (If different from Owner listed above) Address 1 '�Z City State 4. Contractor._�1�• }-� , 1160Zme-Q(!C0M r 'r(Inndlcz 33<< Address City State Contractors Teelephone No.: 5. Surety: /V Name' Address � City State Amount of Bond: $ .-/ Telephone No.: 6. Lender. �L�--� Name Address City State Lenders Telephone No.: 7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)(7),Florida Statutes: /' I Name Address /1 ��— State Telephone Number of Designated Person: 3 8. In addition to himself,the owner designates ��Z�/T of_ to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statutes. Telephone Number of Person or Entity Designated by Owner. 9. Expiration date of Notice of Commencement(the expiration date may not be before the completion of construction and final payment to the contractor,but will be one year from the date of recording unless a different date is specified): WARNING-TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalty of perjury,I declare that I have read the foregoing notice of commencement and that the facts staled therein are true to the best of my knowledge and belief. STATE OF FLORIDA COUNTY OF PASCO _ Srgnat re of Owner or Lessee,or Owners or Lessee's Authorized Officer irector/PartneriManager Sig atory's TitlefOffice �fThe foregoing Instrument was acknowledged before me this A(" . o 20�y as ss-•, (type of authority,e.g.,officer,trustee,attorney in fact)for (name of party o behalf of horn instrum nt was executetl). Personally Known Q�R Produced Identification❑ Notary Signature Type of Identification Produced Name(Print) Notary Pabft State of FWda c�(f�."'t Michelle Moyes % MY Commlaslon GG 057321 ern MOMS wpdata/b cs/noticecommen cement_pc053048 DR Horton-6605 Wagon Trail St-3,085 sq ft- o umn Es SO. FEET PRICE MAIN OR LIVING: 3,085 $ 112.65 OTHER AREA UNDER ROOF: - $ - OTHER: - $ - VALUATION $ 347,525.25 FEE SHEET $ 1,232.00 ADDRESS $ 40.00 DRIVEWAYJ $ 40.00 BUILDING: $ 1,336.64 ELECTRICAL: $ 277.20 j PLUMBING: $ 184.80 MECHANICAL: $ 129.36 SUB-TOTAL $ 1,928.00 TOTAL $ 1,928.00 SEWER: WATER: IRRIGATION: $ - TOTAL: $ - WATER METER: IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: $ - INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $. 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 2,481.35 PARK IMPACT FEES $ 769.56 SIF'S: $ 4,828.00 100.0% $ 4,828.00 1.0% $ 48.28 TOTAL: $ 4,876.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 11,759.19 05-26-21-0080-00600-0320 Pasco County Property Appraiser Page 1 of 1 i Data Current as Of: Weekly Archive - Monday, April 16, 2018 Parcel ID 05-26-21-0080-00600-0320 (Card: 001 of 001) Classification 00 - Vacant Residential Mailing Address Property Value DR HORTON INC Ag Land $0 12602 TELECOM DR Land $24,347 TEMPLE TERRACE FL 33637-0935 Building $0 Physical Address Extra Features $0 . 6605 WAGON TRAIL STREET ZEPHYRHILLS, FL 33541 Just Value $24,347 Legal Description (First 4 Lines) Assessed (Non-School Amendment 1) $24,347 See Plat for this Subdivision Taxable Value $24,347 SILVERADO RANCH SUBDIVISION PHASES 6, 8 &9A PB 75 PG 075 BLOCK 6 LOT 32 Jurisdiction City of Zephyrhills Land Detail (Card: 001 of 001) Line IUse IDescriptionlzoning Units Type Price Condition Value 1 0100_ SFR _1 MPUD 6,000.00 http://search.pascopa.com/parcel.aspx?parcel=2126050080006000320 4/19/2018 I Single _Family Dwelling Plan Review.Comrrients 1: .F.F:E. shall be a minimum of.8"above.the road elevation and an engineered site plan. 2. -Lots-shall be graded.to.comply with R401.3 of the F.B:C. 3. .Compaction:test required if 24" or more of fill dirt is brought in at any one place. . :.4. :Tie in survey required before pouring concrete.. 5.. Driveways require a R;O.W. use permit: All 4,sides of driveway thru the sidewalk shall have expansion material:. - 6- All setbacks.shall be,met... . .7.: All.property markers be.uncovered and marked.at time of first.inspection: - 8 All A.D.A.-requirements.shall be met.: . 9.: .No:electric;plumbing,mechanical;_or framing shall be covered without an,inspection-arid approval first. 10. All Garages shall:comply,with:section R302:6 of the F.B.C,::(Fire S:eparation).. 11: Appliances shall iiot:be installed in a location where subjectto.rnechariical damage unless. .protected:by approved barriers. M303-.4 of.the F.B:C 12. Water heaters shall comply:with section.P607.3 of the F.B.C: 13. Foundation supports:forA/C units.shall be raised at least 3"above finished"grade,. M1308.1 - 14. Return air in all.bedrooms..F.B.C. ,M,I620.4, 15. Smoke detectors'are to be iristalled:iri accordance with R313:1 'of the F.B,C. 16:.All glazing requirements are.to be in accordance with R308.4.of the F.B.C. . 17. All means of egress are to be in-accordance with R31 Lof the R.B.C. 18. `.`Green gypsum board" shall riot be used as.a backer iri showers'ortubs. R702.4:2.F.B.C. 19. Combination-type-AFCI breakers are.reguired.at all,locations requiring an AFCI,type breaker: 20: Carbon monoxide.alarms Will be required in new-construction that-uses fossil-burning:heating or appliances or an attached garage: They shall be.installed in accordance with the F,B.C: . 21. All plumbing,mechanical,'and electrical shall be separate from unit to:unit: This includes all ad elecfiunderground:plurin c: 22. All 2011:N:E.C: Codes will be enforced: 23.Tamper-Resistant Receptacles in accordance with 406.11 of the 2011 N.E:C 24: In accordance..with the Land.Development.Code;lots shall be sodded before final at least 10 feet around the structure: 25 A.copy of the energy cacls shall be-with wermitat all times. 26.Copy of final insulation report shall be.provided with.permit before.finab F:F-E.-Finished Floor-Elevation F.B:C-Florida Building.Code 6t'Edition R.O.W.-Right of Way- A.D.A.-Americans with Disabilities Act N.E.C.-National Electric:Code.(2011) 40 I PASCO COUNTY, FLORIDA r , Permit No. � 1 Date Permitted Builder Name/Owner Name tS�c Control#' County Parcel No. 05-2�- 21—©o&>-066m--f)3 2,o SubDiv: c 0tfw_t p Address/Location �( o'5 (..f o-cul'A Classification/Type of Use "4 TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: D .S _ t` Exempt [I' Yes ❑ No How Determined Impact Fee Amount $. 316 32'0b Zane No. TAZ: SCHOOL IMPACT FEE tt Account (056) Single-Family Detached House Amount $ Ti �p- Zt� (057). Mobile Home (058) Other Residential 23) Collection Fee Exempt d Yes ❑No How Determined PARKS AND RECREATION FEE Land Account Land Credit Land Total Recreation Account Recreation Credit -Recreation Total Zone TOTAL AMOUNT $ 7_7 cS,F,+ Exempt ❑Yes ❑ No How Determined LIBRARY FEE Land Account Land Credit Land Total Facility Account Facility Credit Facility Total Exempt 0 Yes ❑ No How Determined Total Amounf_� RESOURCE FEE ERU TOTAL AMOUNT Prepared By Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE.OF PASCO COUNTY Acknowledgement below does not-imply acceptance of concurrence,but simply receipt of-a copy of this form,placing the building permit owner on notice of this assessment and the conditions of payment for same. { DATE RECEIVED BY RECEIPT NO. DATE BY 913-780-0020 City of Zephyrhiils Permit Application Fax=813-780 0021 Building Department Date Received Phone Contact for Permitting - 'T Owner's Name frt t c� r-. C Owner Phone Number i`I�L �•t EI Owner's Address ioZ�Q e � �n^ �, rr 1 G��fa� J� ����Owner Phone Number Fee Simple Titleholder Name �. C ,v-i Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS Qom} C111 �`(�} ( L 3 S LOT# 3Z .SUBDIVISION �� l �'��'<-- ZA Gx PARCEL ID# e r (OBTAINED FROM PROPERTY TAX NOTICE) ' WORK PROPOSED NEW CONSTR 8 ADD/ALT 0 SIGN' 0 DEMOLISH INSTALL REPAIR PROPOSED USE ©''� SFR COMM �� " . OTHER• TYPE OF CONSTRUCTION _ [ � BLOCK : FRAME STEEL DESCRIPTION OF WORK -5 Fe5"}tlJ -e- e.S A?c:.�-� BUILDING SIZE SO FOOTAGE HEIGHT �� 'T-¢"r"rrir'�Ir-t�'z'�rrlrir>rv-i'T"�"rrr'Ir'�frt'T'Tr�v-r r'-r'v�mlrP�nl->t"Q^TP's�'Q�IY'7'�^oTtr"r�e"c-1��-c'e��9�' =BUILDING $ W 0 VALUATION OF TOTAL CONSTRUCTION ELECTRICAL $. W AMP SERVICE 0 PROGRESS ENERGY 0 . W.R.E.C. 0 =PLUMBING =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION 4f_ [7,0 =GAS ROOFING SPECIALTY OTHER FINISHED FLOOR ELEVATIONS ( �; FLOOD ZONE AREA =YES " NO -@-1-1-44-1=4-@-i- .-8:-i+8--C-C-i-e-�0- -�6-8---. --B-F---1-W--@-G-@ @•-8�:-:-6�-:-•8�-8-:-�e-@-8-8- - -•s8•-1-1-@-t g 16.9 •° -@-@--C-4-S-• BUILDER �! "� :,/�. �� COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address %ol? ! /� r�C ✓r7 P` l -r�� �. t✓�, �09`10 6 A License# �/' h ,.ELECTRICIAN � r�,��- COMPANY ��°Ii?00! 1lla,03 ���'+ �C7�'� C SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address License# � < PLUMBER �•�' _ COMPANY SIGNATURE /� rl REGISTERED Y/ N FEE CURREN Y/�N/ l Address License# p MECHANICAL COMPANYP�t� Ys - SiGNATURE REGISTERED Y// N FEE CURREN Y/N Address D 2 License# � OTHER SIGNATURE ."`�-�'� - COMPANY )ll x � � t): ;.•�{" _ f-� pt �� REGISTERED Y/ N FEE CURREi\ LILIN Address License# 11 ! { 1111111tt11tlllitt } ttlltltlJllllllllttllltl1I1 .111@ ! @181t1@88l8 ! RESIDENTIAL Attach(2)Plot Plans; (2)sets 6f Building Plans; (1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Sift•Fence installed, Sanitary Facilities&1 dumpstei;Site Work'Permit for subdivisions/large projects COMMERCIAL Attach.(2)complete sets of Building Plans plus a Life Safety Page; (1)set of Energy Forms.R-O-W Permit for new construction. Minimm ten (10)working days.after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Sift Fence installed, Sanitary Facilities&1 dumpstei.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach (2)sets of Engineered Flans. "PROPERTY-SURVEY required for all NEW construction. Directions:.1.-8-a-1--t-.<-1-e-•@-•@--@=i-1•-1-1-1-,5.:,".8..d-i_M-1-.@.->s-.d-8-@-@..8-6.-&.e-•1--1--8-.8-.A.-@.-@-�.8-.8--&-•�-b.�.�t--G-e.e1��1�@-�-8-@-d. Fill out application completely. Owner$,Contractor sign back of application,n�'.mrized if over$2500,a Notice of Commencement is equired. (A/C upgrades over$750o) - " Agent(for the contractor)or Power of Attorney the owner)would be someone with notarized'letter:from owner authorizing same DVER THE COUNTER PERMITTING (copy of contract required) 3eroofs if shingles - Sewers Service Upgr_,des A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadwii,•",.needs ROW \ ' ` . . ` NOTICE OF DEED S: The undersigned VndenstamdsthotthkspenDitmoybe subject deed" restrictions",. regulations.which may be more res�|otivethan [|ounty The undersigned assumes reoponoibU ' for oonnpUan compliance ^� applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors tnundedake work, they may be required 1obe licensed in accordance with state and-/noa| regu|a1iona. 'If.the contractor is not-licensed as required by law, both the owner and contractor may be cited for a 'misdemeanor violation under state law. If the owner or intended�onntnantor are uncertain as to vvho1 licensing requirements may,apply for the intended work, they are,advised to contact the Pasco County Building Inspection Division--Lidens\nQ Section at727-O4T- ` OODS. Fudhe[more, if the owner has hired a contractor or contrautoro, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the con tractor, that may bean indication that heio not properly licensed and is not entitled to permitting phvi/ege&in Pasco County. � TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands thstTnanspnrtetion |nnpentFeeaandRacounseRecoveryFeasnnayapplytotheoonstructionofnexvbuUd|ngs, changeof use In RX|ot|ng bUi|d|ngs, or expansion of existing bui|dinga, as specified in Pasco County Ordinance number 89'07 and 00'07. as amended. The undersigned also.undenstand&, that such foes, as may be due, will be identified a1 the time of permitting. It is furth ter understood that Transportation impact Fees and Resource Recovery Fees, must be paid prior to receiving m "oert�cate of occupancy" or final power release. U the project does not involve a certificate of occupancy or final power re|eeoa, the fees must be paid prior to permit issuance. Furthermore, if Pasco CountyVVa1er/Genwer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW (Chapter 713. Florida Statutes, agonmendwd\: |f valuation of\qorkis$2.5OO.0Oormore, I. norUfv that i' the applicant, have been provided with a copy of the "Florida Construction, Lien Law—Homeowner's Protection Guide" red by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone otherthontha''ovxner", } Pertifvthat \ heveobta|nedocopyoftheabVvodesor|beddmcurnantandprono\ma |ngoodfaithto deliver itto the^ovvner' prior tocommencement. CONTFbACTC)R/SIOWNER'S AFFIDAVIT: i certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating.construction, zoning and land development. Application is ` hereby made to obtain a permit to do work and installation as indicated. | certify that no work or installation has commenced prior to issuance of o permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes,* zoning regulations, and land development regulations.\n the jurisdiction. | also certify that \ understand that the regulations of othe� government agencies may apply tothe intended work, and that it is responsibility Such agencies include but are not UnldBd�t my ��pona , ' ~ ' ' Department of Environmental Protection-Cypress Bayheado, Wetland Areas and Environmentally Sensitive Lands,'VVatnn%VestevvetarTreatment. - Southwest Florida VVo1er Management D|atriot-WoUa, Cypress 8ayhoads, Wetland Areas' Altering Watercourses. ` . - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. ` - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment,'.*. Septic Tanks. ` - US-Environmental Protection Agency-Asbestos abatement. ' - Federal Aviation Authordy-Runvvays. | understand that the following restrictions apply to the use offill: - Use of fill io not allowed in Flood Zone"V" unless expressly perrnittad` - |ftha fill material is to be used in Flood Zone "A". it is understood that o drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a prVfeas|ona| engineer licensed by the State ofFlorida. - (f the fill nnahehe) is to be used in Flood Zone "�� in connection v�th a permitted building using etennxv�U oonstrucbon. \ uarbfv that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area. | certify that use of such fill will not adversely affect adjacent . properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots |ema than one M\ acre which are elevated by fill, an engineered drainage plan |arequired. |f \ ann the AGENT FOR THE OWNER, I promise in good faith-to inform the owner of the permitting conditions bet forth in this affidavit prior to ournnmmnoing oonstrucL\on� understand unde �and that a separate permit may be.required for electrical vvorh. p|umbing, oigns, wa||e, pools, air conditioning, gas,,or other installations not specifically included in the application. A permit issued shall be const�ued to be a license to proceed with-the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official.from thereafter requiring a correct!onof errors�in plans, construction or violations of any codes. Every permit issued shall become invaUd unless the work authorized by such permit is commenced vvhh\n six months of penn|L |osuance, or if work authorized by thapernnitiosuspendedorabandonedf0rapohod^ofoiz (S) rnnrthaofterthgbnnethem/orkiacornrnencod. An extension may be requested, in vvr|ting, from the Building.Official for o period not to exceed ninety (QD) days and will demonstrate ` justifiable cause for the extension. |fvvO[kceasesforninaty (SO) nonaenutivgdaya.thejob |uoons|deredabundona . WARNING TO OWNER- YOUR FAILURE TO RECORD ANOTICE OF COMMENCEMENT MAY RESULT lN YOUR. PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. iF YOU INTEND T0 OBTAIN FINANCjNG,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.' FLORIDA JURAT( ) . lip :owrnAoTo Subscribed and . ' � ` before me this Who is/are personalIV known to me or has/have,produced Who,islare personally known to me or has/have identification,as identification.~ . . - . ' Pu blic Commisaion No. Commission No. ` « ' Name orNotary typed,printed mrstamped Name o*Notary typed,printed mstamped ow P& Notary Public State of Florida PLOT PLAN DESGRIPTION:(AS FURNISHED) LOT 32, BLOCK 6, SILVERADO RANCH SUBDIVISION PHASE 6, 8 & 9A AS RECORDED IN PLAT BOOK 75, PAGE(S) 75-80, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. PT LOT 33 m BLOCK 6 m I I Wi 0 �1�k,�\lei ,`�'1•� �O Z , ., i = 1" = 30' S87'24 2$ E 124.86' N87'24'28'W I�� GRAPHIC SCALE I __ 30.00' 0 15 30 >- O ( 59.7' a/c I ---- Z uNi i 40.7' 24.5 •� 1n p}a I a :°]' o J<-10 x _ I U N W Or n NOW ILL q �..Q..I.... >':.'.: LLI Li o W LL �' x0 cV I Q c� m OQme� v. 2.0' `I`.::•:..'.�.;+..:'':: �p� aO I m F 4 1 D5r- Q . IfO J� 2 16 I a rLo ¢ oNo; 6.0 Q b :a 3 42.67' I I Z 59.7'--� 36.7' I I n I j 28s'I I 5.0 fn� (N87'24'28"IN ¢Q 124.86 I J �o Qi INW I io rim m ow LOT 31 I a� Ng BLOCK 6 t5 I az I � I I I ON LOT CALCULATIONS LOT = 6,867 SQ. FT. LIVING AREA = 1,104 SQ. FT. GARAGE = 437 SQ. FT. PG ENTRY = 53 SQ. FT. LANAI = 0 SQ. FT. PATIO = 80 SQ. FT. DRIVEWAY = 392 SQ. FT. A/C PAD = 12 SQ. FT, WALKWAY = 30 SQ. FT. IMPERVIOUS = 31% = 2108 SO. FT. SOD = 4,759 SQ. FT. PREPARED FOR: OFF LOT CALCULATIONS RIGHT OF WAY = 715 SQ. FT. DRIVE H'RHORII N PUBLICAS/WN = 275 SQ. FT. a9GNl �sjCdtjGYe SOD = 288 SQ. FT. TOTALS BUILDING SETBACKS AREA = 7,582 SQ. FT. DRIVEWAY = 544 SQ. FT. FRONT- 22' SIDEWALK = 305 SQ. FT. REAR: 15, SOD = 5.047 SQ. FT. SIDE: 7.5 SIDE STREET: 20' ' LEGEND: NOTES: — ' —' — BUILDING SETBACK LINE PI POINT OF INTERSECTION PC POINT OF CURVATURE 1. ELEVATIONS SHOWN ARE PER LOT GRADING — CENTERLNE PT POINT OF TANGENCY PLANS PROVIDED BY THE CLIENT. — — RIGHT of WAY LINE RP RADIUS POINT ' 2. ELEVATIONS ARE BASED ON NAVD 1988 XX PR C POINT OF REVERSE CURVATURE XX. PROPOSED ELEVATION PCC POINT OF COMPOUND CURVATURE DATUM. TYP TYPICAL PROPOSED DRAINAGE FLOW CS CONCRETE SLAB THIS PLOT PLAN IS INTENDED FOR PERMITTING PURPOSES CONCRETE �P) PER PLAT CALCULATED ONLY. THIS IS NOT INTENDED FOR THE CONSTRUCTION OF THE PROPOSED HOUSE. REFER TO HOUSE PLAN AND PB PLAT BOOK A/c AIR CONDITIONER OPTION LIST FOR CONSTRUCTION. ALL BUILDING SET BACK S/W SIDEWALK SO. PAGES SO. FT. SQUARE FEET LINES SHOWN HEREON IS PER DATA FURNISHED BY CLIENT F.E.M.A. FEDERAL EMERGENCY MANAGEMENT AGENCY AND IS FOR INFORMATIONAL PURPOSES ONLY. F.I.R.M. FLOOD INSURANCE RATE MAP NAVD NORTH AMERICAN VERTICAL DATUM THIS IS NOT.A SURVEY D&LIE DRAINAGE &UTILITY EASEMEONAL GEODETIC NT ATUM PRIVATE DRAINAGE THIS IS A PLOT PLAN ONLY UEE UTILITY EASEMENT(PUBU).T FI.WD NOT9 SURVEYOR NOTES: I HAVE EXAMINED THE F.I.R.M. MAP NO. 12101CO288F, 1. THE SURVEYOR HAS NOT ABSTRACTED THE DATED SEPTEMBER 26. 2014. AND FOUND THE SUBJECT PROPERTY LAND SHOWN HEREON FOR EASEMENTS, RIGHT APPEARS TO UE IN ZONE'X', AREAS DETERMINED TO BE OUTSIDE THE OF WAY, RESTRICTIONS OF RECORD WHICH 0.2%ANNUAL CHANCE FLOODPLAIN. THE SURVEYOR MAKES NO MAY AFFECT THE TITLE OR USE OF THE LAND. ' GUARANTEES AS TO THE ABOVE INFORMATION. PLEASE CONTACT THE LOCAL F.E.M.A. AGENT FOR VERIFICATION. 2. NO UNDERGROUND IMPROVEMENTS HAVE BEEN LOCATED EXCEPT AS SHOWN. BEARING BASIS: BEARINGS SHOWN HEREON ARE BASED ON THE CENTERLINE OF WAGON 3. NOT VALID WITHOUT THE AUTHENTIC TRAIL STREET BEING S0235'32'W, PER PLAT. ELECTRONIC SIGNATURE AND THE AUTHENTIC ELECTRONIC SEAL OF A FLORIDA LICENSED REVISED: AMERICAN SURVEYOR AND MAPPER. (FIELD DATE:) S U FR V E Y I N G SCALE: 1'= 30 FEET `z:�H.,• Digizallysigned bylamesWB=leman 8e MAPPING I N C. °"` �: DN:cMlamez W Boleman American APPROVED BY: JB � ua) - —m Hbolema=@ sg=' ,poratecom, CERTIFICATION OF AUTHORIZATION NUMBER LB 6393 �:s<^'�"� •t 3191 MAGUIRE BOULEVARD, SUITE 200 �`•'^:;•`�`�'li'' µ Da,e:x0n.n.160rin:,4-0S•orc THE FOR JOB NO. 171013 LOT 32, BLK 6 ORLANDO. FLORIDA 32803 1, FIRM (407) 426-7979 DRAWN BY*.* DSB PLOT PLAN 11 13 17 KJW WWW.AMERICANSURVEYINGANDMAPPING.COM JAMES W. BOLEMAN PSM# 6485 DATE ' FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: ayden 2605 Elev C,/ Builder Name: DRH Express Homes Street: ( -"6l S4- M Permit Office: GiCity,State,Zip: Zephy ills, FL,33�\ Permit Number:Owner: n Jurisdiction: (((p Design Location: FL,Tampa 3 County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(2614.2 sgft.) Insulation Area a.Frame-Wood, Exterior R=11.0 1285.30 ftz 2. Single family or multiple family Single-family b.Concrete Block-Int Insul, Exterior R=4.1 996.67 ft2 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 332.22 ftz 4. Number of Bedrooms 5 d.N/A R= ftz 10.Ceiling Types (1541.0 sqft.) Insulation Area 5. Is this a worst case? No a.Under Attic(Vented) R=30.0 1541.00 ftz 6. Conditioned floor area above grade(ftz) 2605 b.N/A R= ftz Conditioned floor area below grade(ftz) 0 c.N/A R= ftz 11. Ducts R ftz 7. Windows(250.0 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 261 a. U-Factor: Dbl,U=0.34 210.00 ftz SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.55 40.00 ftz 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.34 a.Central Unit 40.0 SEER:14.00 c. U-Factor: N/A ftz SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ftz a.Electric Heat Pump 41.0 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 1.052 ft. Area Weighted Average SHGC: 0.315 14.Hot water systems 8. Floor Types (1541.0 sgft.) Insulation Area a.Electric Cap:50 gallons EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1104.00 ftz b. Conservation features b.Raised Floor R=19.0 437.00 ftz None c.N/A R= ftz 15.Credits Pstat Glass/Floor Area: 0.096 Total Proposed Modified Loads:' 78.51 PASS Total Baseline Loads: 79.15 1 hereby certify that the plans and specifications covered by Review of the plans and L11%41 S7,q? this calculation are in compliance with the Florida Energy specifications covered by this „�+� .e0� Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: L N>L�P.,��. Before construction is completed DATE: II-II-17 this building will be inspected for compliance with Section 553.908 * ° St atutes. tatutes. .+ I hereby certify that this building,as designed,is in compliance Florida with the Florida Energy e. OD WE"� OWNER/AGENT: BUILDING OFF CIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. - Compliance with a proposed duct leakage On requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with Section 803 of RESNET Standards, is not greater than 0.050 On for whole house. 11/11/2017 12:55 PM EnergyGaugeRO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 1 ORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: �jayden 2605 Elev C Builder Name: DRH Express Homes Street: kpm-,j llq�-Fcv ( - ` ` Permit Office: City,State,Zip: Zephy ills, FL,359_�\ cU Permit Number: Owner: Jurisdiction: Design Location: FL,Tampa 72 4 County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(2614.2 sgft.) Insulation Area 2. Single family or-multiple family Single-family a.Frame-Wood, Exterior R=11.0 1285.30 ft2 b.Concrete Block-Int Insul, Exterior R=4.1 996.67 ft2 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 332.22 ft2 4. Number of Bedrooms 5 d.N/A R= ft2 10.Ceiling Types (1541.0 sgft.) Insulation Area 5. Is this a worst case? No a.Under Attic(Vented) R=30.0 1541.00 ft2 6. Conditioned floor area above grade(ft2) 2605 b.N/A R= ft2 c. R= ft2 11.Duuctct Conditioned floor area below grade(ft2) 0 s R ft2 7. Windows(250.0 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 261 a. U-Factor: Dbl,U=0.34 210.00 ft2 SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.55 40.00 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.34 a.Central Unit 40.0 SEER:14.00 c. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 41.0 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 1.052 ft. Area Weighted Average SHGC: 0.315 14.Hot water systems a. Electric Cap:50 gallons 8. Floor Types (1541.0 sgft.) Insulation Area EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1104.00 ft2 b. Conservation features b.Raised Floor R=19.0 437.00 ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.096 Total Proposed Modified Loads: 78.51 PASS Total Baseline Loads: 79.15 .7�7 I hereby certify that the plans and specifications covered by Review of the plans and -TIiESp,�Z, this calculation are in compliance with the Florida Energy . specifications covered by this �'� _ �0�, Code. calculation indicates compliance with the Florida Energy Code. lirrrr ''%%r. ;•4�,�0 PREPARED BY: Before construction is completed10 w '' DATE: II-II-17 this building will be inspected for -- r1= n . compliance with Section 553.908 I hereby certify that this building,as designed,is in compliance Florida Statutes. with the Florida Energy e. OWNER/AGENT: BUILDING OFFI IA DATE: I r DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. - Compliance with a.proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with Section 803 of RESNET Standards, is not greater than 0.050 Qn for whole house. 11/11/2017 12:55 PM EnergyGauge@ USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 i I FORM R405-2014 PROJECT Title: Hayden 2605 Elev C Bedrooms: 5 Address Type: Lot Information Building Type: User Conditioned Area: 2605 Lot# 3216 Owner: Total Stories: 2 Block/Su bDivision: Silverado Ranch #of Units: 1 Worst Case: No PlatBook: Builder Name: DRH Express Homes Rotate Angle: 90 Street: Permit Office: Cross Ventilation: County: Pasco Jurisdiction: Whole House Fan: City,State,Zip: Zephyrhills, Family Type: Single-family FL, New/Existing: New(From Plans) Comment: Garage R Face E CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Tampa FL TAMPA_INTERNATI 2 39 91 70 75 645.5 54 Medium BLOCKS Number Name Area Volume 1 Blocki 2605 21579.7 . SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1104 9571.7 Yes 1 1 1 Yes Yes Yes 2 2nd Floor 1501 12008 No 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio Main 152.8 ft 0 1104 ft2 ---- 0.2 0 0.8 2 Raised Floor 2nd Floor ---- ---- 437 ftz 19 0.5 0 0.5 ROOF - / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1723 ftz 0 ftz Dark 0.92 No 0.9 No 0 26.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area FIBS IRCC 1 Full attic Vented 300 1541 ftz Y N I 11/11/2017 12:55 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5 i I FORM R405-2014 CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) Main 30 Blown 40 ftz 0.11 Wood 2 Under Attic(Vented) 2nd Floor 30 Blown 1501 ftz 0.11 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below Ornt To Wall Type 1 N=>E Exterior Concrete Block-Int Insul Main 4.1 18 8 8 8 161.8 ftz 0 0.6 0 2 W=>N Exterior Concrete Block-Int Insul Main 4.1 20 .8 8 173.3 ftz 0 0.6 0 3 S=>W Exterior Concrete Block-Int Insul Main 4.1 39 8 8 8 343.8 ftz 0 0.6 0 4 E=>S Exterior Concrete Block-Int Insul Main 4.1 36 8 8 8 317.8 ftz 0 0.6 0 5 N=>E Garage Frame-Wood Main 11 20 4 8 8 176.2 ftz 0.23 0.01 0 6 W=>N Garage Frame-Wood Main 11 18 0 8 8 156.0 ftz 0.23 0.01 0 _ 7 N=>E Exterior Frame-Wood 2nd Floor 11 39 8 8 317.3 ftz 0.23 0.6 0 8 W=>N Exterior Frame-Wood 2nd Floor 11 40 8 8 325.3 ftz 0.23 0.6 0 9 S=>W Exterior Frame-Wood 2nd Floor 11 39 8 8 317.3 ftz 0.23 0.6 0 10 E=>S Exterior Frame-Wood 2nd Floor 11 40 8 8 325.3 ftz 0.23 0.6 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N=>E Insulated Main None .4 3 6 8 20 ftz 2 N=>E Wood Main None .46 2 8 6 8 17.8 ftz WINDOWS Orientation shown is the entered orientation => changed to As Built rotated 90 degrees). Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N=>E 1 Vinyl Low-E Double Yes 0.34 0.31 31.0 ftz 1 ft 0 in 10 ft 0 in Drapes/blinds None 2 N=>E 1 Vinyl Low-E Double Yes 0.34 0.31 2.5 ftz 6 ft 2 in 0 ft 0 in Drapes/blinds None 3 S=>W 3 Vinyl Low-E Double Yes 0.34 0.31 46.5 ftz 1 ft 0 in 10 ft 6 in Drapes/blinds None 4 S=>W 3 Metal Low-E Double Yes 0.55 0.34 40.0 ftz 1 ft 0 in 1 ft 3 in Drapes/blinds None 5 N=>E 7 Vinyl Low-E Double Yes 0.34 0.31 6.0 ftz 1 ft 0 in 0 ft 6 in Drapes/blinds None 6 N=>E 7 Vinyl Low-E Double Yes 0.34 0.31 31.0 ftz 1 ft 0 in 2 ft 6 in Drapes/blinds None 7 S=>W 9 Vinyl Low-E Double Yes 0.34 0.31 62.0 ftz 1 ft 0 in 0 ft 6 in Drapes/blinds None 8 N=>E 7 Vinyl Low-E Double Yes 0.34 0.31 31.0 ftz 1 ft 0 in 0 ft 6 in Drapes/blinds None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 437.038 ftz 437.038 ftz 48.4 ft 8.67 ft 0 11/11/2017 12:55 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 I l I FORM R405-2014 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000368 2517.6 138.21 259.93 .3402 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump None HSPF:8.2 41 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit None SEER:14 40 kBtu/hr 1 1200 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 50 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS ----Supply---- ----Return---- Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 261 ft2 2nd Floor 45 ft2 Proposed Qn 2nd Floor ---cfm 130.3 cfm 0.05 0.60 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Coolingr 1 Jan Feb rr 11 Mar Apr r May [X]Jun Jul rX�AugX�Se Oct Nov Dec Heatin [X]Jan f X}Feb [X]Mar Apr [ May [ ]Jun Jul [ ]Au [ ]Sep E Oct Nov Dec Venting [[[ ]]]Jan l 1 Feb [[[[[[X]]]]]]Mar Apr [[[ ]]]May [ ]Jun Jul [[[ ]Aug [[[ ]Se lXl Oct Nov Dec 11/11/2017 12:55 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2014 Th6rmostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WE H) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 11/11/2017 12:55 PM EnergyGauge@ USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the EnergyPerformance Index,the more efficient the home. Zephyrhills, FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1285.30 ft2 b.Concrete Block-Int Insul, Exterior R=4.1 996.67 ft2 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 -332.22 ft2 4. Number of Bedrooms 5 d.N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types Insulation Area a.Under Attic(Vented) R=30.0 1541.00 ft2 6. Conditioned floor area(ft2) 2605 b.N/A R= ft2 7. Windows" Description Area c.N/A R= ft2 2 a. U-Factor: Dbl,U=0.34 210.00 ft2 11• Ducts R ft a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 261 SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.55 40.00 ft2 SHGC: SHGC=0.34 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a.Central Unit 40.0 SEER:14.00 SHGC: d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 41.0 HSPF:8.20 Area Weighted Average Overhang Depth: 1.052 ft. Area Weighted Average SHGC: 0.315 8. Floor Types Insulation Area 14.Hot water systems Cap:50 gallons a.Slab-On-Grade Edge Insulation R=0.0 1104.00 ft2 a. Electric EF:0.95 b.Raised Floor R=19.0 437.00 ft2 c.N/A - R= ft2 b. Conservation features None . 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building xE ST Construction through the above energy saving features which will be installed (or exceeded) •;,�� a O in this home before final inspection. Otherwise, a new EPL Display Card will be completed �<v�',,,;'°•r' based on installed Code co t features. 04 Builder Signature: Date: {`{ Address of New Ho e: City/FL Zip: r t( GAD *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 1 1/1 1/2017 1 2:55 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 FORM F1405-2014 Florida Department of Business and Professional Regulations Residential Whole Building Performance and Prescriptive Methods ADDRESS: Permit Number: Zephyrhills,FL, MANDATORY REQUIREMENTS See individual code sections for full details. 401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law [Section 553.9085,Florida Statues]requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate compliance for the.building.A copy of the EPL display card can be found in Appendix C. R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.1 through R402.4.4. O R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.The sealing methods between dissimilar materials shall allow for differential expansion and contraction. • R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table 402.4.1.1,as applicable to the method of construction. Where required by the code official,an approved third party shall inspect all components and verify compliance. • R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2,and 3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3.Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. O R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers and outdoor combustion air. O R402.4.3 Fenestration air leakage.Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2);when tested according to NFRC 400 or, AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. O R402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential.All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. R403.2.2 Sealing(Mandatory)AII ducts,air handlers,and filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post-construction or rough-in testing below. Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either an energy rater certified in accordance with Section 553.99,Florida Statutes,or as authorized by Florida Statutes,to be"substantially leak free"by either of the following: 1. Post-construction test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure.All register boots shall be taped or otherwise sealed during the test. 2. Rough-in test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g. (25Pa)across the system,including the manufacturer's air handler enclosure.All registers shall be taped or otherwise sealed during the test. If the air handler is not installed at the time of the test,total leakage shall be less than or equal to 3 cfm (85 Umin)per 100 square feet(9.29 m2)of conditioned floor area. Exceptions: 1. The total leakage test is not required for ducts and air handlers located entirely within the building envelope. 2. Duct testing is not mandatory for buildings complying by Section R405 of this code. 11/11/2017 12:55 PM EnergyGauge@ USA-FlaRes2014 -Section R405.4.1 Com Page 1 of 3 FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) ❑ R403.2.3 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. ❑ R403.3 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 1050F(41°C) or below 55°F(131C)shall be insulated to a minimum of R-3., R403.3.1 Protection of piping insulation. ❑ R403.4.1 Circulating hot water systems(Mandatory). Circulating hot water systems shall be provided with an automatic or readily accessible manual switch that can turn off the hot-water circulating pump when the system is not in use. ❑ R403.4.3 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3 1/2 inches(89 mm)in the hot water distribution line and cold water line located as close as possible to the storage tank. ❑ R403.4.4 Water heater efficiencies(Mandatory). O R403.4.4.1 Storage water heater temperature controls • R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature setting range shall be from 1001F to 140°F(38°C to 60°C). • R403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s) of combustion types of service water heating systems to be turned off. O R403.4.4.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation,Commercial Provisions,for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1. R403.4.4.2.1 Solar water heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors, and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol,Collectors in installed solar water heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and 2. Be installed at an orientation within 45 degrees of true south. ❑ R403.5 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code, Residential or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. ❑ R403.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment. O R403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1.This code does not allow designer safety factors,provisions for future expansion or other factors which affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. • R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load,but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.6,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load. 11/11/2017 12:55 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Com Page 2 of 3 FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) O R403.6.1.1 Cooling equipment capacity.(continued) The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacture's expanded performance data shall be used to select cooling-only equipment.This selection shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower cfm provided by the expanded performance data, the design value for entering wet bulb temperature and the design value for entering dry bulb temperature. Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space. Exceptions: 1. Attached single-and multi-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida-registered engineer,in attached single-and multi-family units,the capacity of equipment may be sized in accordance with good design practice. O R403.6.1.2 Heating equipment capacity R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section R403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load. R403.6.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.6.1. R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.6.1. O R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. ❑ R403.7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the Commercial Provisions in lieu of Section R403. ❑ R403.8 Snow melt system controls(Mandatory). Snow and ice-melting systems,supplied through energy service to the building,shall include automatic controls capable of shutting off the system when the pavement temperature is above 55°F,and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F. ❑ R403.9 Swimming pools,inground spas and portable spas(Mandatory). The energy requirements for residential pools and inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSI/APSP-15.The energy requirements for portable spas shall be in accordance with ANSI/APSP-14. O R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on-off switch that is mounted outside the heater to allow shutting off the heater without adjusting the thermostat setting. R403.9.1.1 Gas and oil-fired pool and spa heaters. All gas-and oil-fired pool and space heaters shall have a minimum thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013 when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights. R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. O R403.9.2 Time switches. Time switches or other control method that can automatically turn off and on heaters and pumps according to a preset schedule shall be installed on all heaters and pumps.Heaters,pumps and motors that have built in timers shall be deemed in compliance with this equipment. Exceptions: • 1. Where public health standards require 24-hour pump operations. 2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation. O R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Outdoor pools deriving over 70 percent of the energy for heating from site-recovered energy,such as a heat pump or solar energy source computed over an operating season. ❑ RR404.1 Lighting equipment(Mandatory). A minimum of 75 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps. Exception: Low-voltage lighting shall not be required to utilize high-efficacy lamps. O R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights ❑ R405.2 Performance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R-6. O R405.2.1 Performance ONLY. Ceilings shall have minimum insulation of R-19.Where single assemby of the exposed deck and beam type or concrete deck roofs do not have sufficent space, R-10 is allowed. 1 1/1 1/2017 12:55 PM EnergyGaugeO USA-FlaRes2014 -Section R405.4.1 Com Page 3 of 3 I j FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Hayden 2605 Elev C Builder Name: DRH Express Homes Street: Permit Office: City,State,Zip: Zephyrhills, FL, Permit Number: Owner: Jurisdiction: Design Location: FL,Tampa COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls - and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows,skylights and doors The space between window/door jambs and framing and skylights and framing shall be sealed. Rim 'oists Rim joists are insulated and include an air barrier. i Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. I Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations,and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit,or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity s aces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated,and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 1 1/1 1/2017 12:55 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 i FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Envelope Leakage Test Report Prescriptive and Performance Method Project Name: Hayden 2605 Elev C Builder Name: DRH Express Homes Street: Permit Office: City,State,Zip: Zephyrhills, FL, Permit Number: Design Location: FL,Tampa Jurisdiction: Cond.Floor Area:: 2605 sq.ft. Cond.Volume: 21580 cu ft. - Envelope Leakage Test Results Leakage Characteristics Regression Data: C: n: R: CFM(50): Single or Multi Point Test Data HOUSE PRESSURE FLOW: ELA' 1 Pa cfm EgLA: 2 Pa cfm ACH: 3 Pa cfm ACH(50): 4 Pa cfm 5 Pa cfm SLA. 6 Pa cfm R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2,3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1. Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3.Interior doors,if installed at the time of the test,shall be open; 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. I hereby certify that the above envelope leakage Where required by the code official, O�,V%ES7,q? performance results demonstrate compliance testing shall be conducted by an ' ,,, r = 0*6 with Florida Energy Code requirements in approved third party. A written ''���•�tr;,. accordance with Section R402.4.1.2. report of the results of the test shall be signed by the third party ...__.:V. v conducting the test and provided to ail!: n SIGNATURE: the code official. PRINTED NAME: BUILDING OFFICIAL: - DATE: DATE: 11/11/2017 12:55 PM EnergyGauge@ USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 Duct Leakage Test Report Performance Method i i FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Form R405 Duct Leakage Test Report Performance Method Project Name: Hayden 2605 Elev C Builder Name: DRH Express Homes Street: Permit Office: City,State,Zip: Zephyrhills,FL, Permit Number: Design Location: FL,Tampa Jurisdiction: Duct Test Time: Post Construction Duct Leakage Test Results CFM25 Duct Leakage Test Values Line System Outside Duct Leakage 1 System 1 cfm25(Out) 2 System 2 cfm25(Out) 3 System 3 cfm25(Out) 4 System 4 cfm25(Out) 5 Total House Sum lines 1-4 Duct System Divide by Leakage (Total Conditioned Floor Area) (Qn,Out) I certify the tested duct leakage to outside, Qn, is Duct tightness shall be verified by 41E SAT not greater than the proposed duct leakage Qn O = F testing to Section 803 of the RESNET ti r �� 0� specified on Form R405 2014. Standards by an energy rater certified in ''�� accordance with Section 553.99, Florida Statutes. SIGNATURE: PRINTED NAME: COD yy&�4���. DATE: BUILDING OFFICIAL: DATE: 11/11/2017 12:55 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant S Page 1 of 1 i I Job: - wrightsoft� Manual S Compliance Report Date: Oct 10,2014 Entire House By: Progressive Air Systems, Inc 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 'Project • • For: DR Horton/Express Lot 32 Blk fi Silverado Ranch, Zephyrhills, FL Cooling Equipment Design Conditions Outdoor design DB: 91.2°F Sensible gain: 32517 Btuh Entering coil DB: 76.4°F Outdoor design WB: 77.1 OF Latent gain: 4144 Btuh Entering coil WB: 63.2°F Indoor design DB: 75.0°F Total gain: 36660 Btuh Indoor RH: 50% Estimated airflow: 1367 cfm I Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB042****A+FB4CNP042 Actual airflow: 1367 cfm Sensible capacity: 32445 Btuh 100%of load Latent capacity: 6269 Btuh 151%of load Total capacity: 38714 Btuh 106%of load SHR: 84% atinI • Equipment , Design Conditions Outdoor design DB: 40.0°F Heat loss: 27149 Btuh Entering coil DB: 69.5°F Indoor design DB: . 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipmenttype: Split ASHP Manufacturer: Carrier Model: CH14NB042****A+FB4CNP042 Actual airflow: 1367 cfm Output capacity: 37299 Btuh 137%of load Capacity balance: 31 OF Supplemental heat required: 0 Btuh Economic balance: -99 OF Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 1367 cfm - Output capacity: 8.6 kW 108%of load Temp. rise: 18 OF Meets are all requirements of ACCA Manual S. wri htsoft, 2017-Nov-11 12:56:20 r' 9 Right-Suite®Universal 2017 17.0.21 RSU25554 Page 1 ACCk ...\Wdghtsoft Files\Express homes\Hayden-4EHB.nip Calc=MJ8 House faces: E Load Short Form Job: wrightsofte Date: Oct 10,2014 Entire House By: Progressive Air Systems, Inc 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 Project Information For: DR Horton/Express Lot 32 Blk 6 Silverado Ranch, Zephyrhills, FL Designinformation Htg Cig Infiltration Outside db(OF) 40 91 Method Simplified Inside db(OF) 70 75 Construction quality Semi-tight Design TD (°F) 30 16 Fireplaces 0 Daily range - L Inside humidity (%) 50 50 Moisture difference(gr/lb) 26 54 HEATING EQUIPMENT COOLING EQUIPMENT Make Carrier Make Carrier Trade CARRIER Trade CARRIER Model CH14NB042****A Cond CH14NB042****A AHRI ref Coil F134CNP042 AHRI ref Efficiency 8 HSPF Efficiency 11.3 EER, 13.7 SEER Heating input Sensible cooling 30750 Btuh Heating output 38500 Btuh @ 47°F Latent cooling 10250 Btuh Temperature rise 26 OF Total cooling 41000 Btuh Actual air flow 1367 cfm Actual air flow 1367 cfm Air flow factor 0.050 cfm/Btuh Air flow factor 0.042 cfm/Btuh Static pressure 0.56 in H2O Static pressure 0.56 in H2O Space thermostat Load sensible heat ratio 0.89 Capacity balance point=31 OF Backup: Input=9 kW, Output= 29290 Btuh, 100 AFUE ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ftz) (Btuh) (Btuh) (cfm) (cfm) kitchen/living 608 7370 9498 371 399 bed 2 164 2960 2160 149 91 powder 59 968 364 49 15 flex 156 3106 2721 156 114 foyer 75 1443 840 73 35 stairs 44 0 0 0 0 bed4 181 1647 2357 83 99 bed3 184 1965 2858 99 120 wic 60 143 176 7 7 wic 2 32 706 781 36 33 m suite 277 2507 3561 126 150 bath 135 355 353 18 15 upstairs living 234 1366 3067 69 129 stairs 2 50 0 0 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wri htsoft® 2017-Nov-1112:56:20 9 Right-Suite®Universal 2017 17.0.21 RSU25554 Page 1 ACCA ...\Wrightsoft Files\Express homes\Hayden-4EHB.rup Cale=MJ8 House faces: E bed5 175 1606 2314 81 97 laundry 41 368 912 19 38 a/c 19 0 0 0 0 bath 3 96 639 555 32 23 hall 63 0 0 0 0 Entire House d 2651 27149 32517 1367 1367 Other equip loads 0 = 0 Equip. @ 1.00 RSM 32517 Latent cooling 4144 TOTALS 2651 27149 36660 1367 1367 i I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wri htsoft6 2017-Nov-1112:56:20 9 Right-Suite®Universal 2017 17.0.21 RSU25554 Page 2 /CCK ...\Wrighlsofl Files\Express homes\Hayden-4EHB.rup Calc=MJ8 House faces: E Project Summary Jo b: wlrightsoft® Date: Oct 10,2014 Entire House 13k: Progressive Air Systems, Inc 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 Project Information For: DR Horton/Express Lot 32 Blk 6 Silverado Ranch, Zephyrhills, FL Notes: Design Informatton Weather: Tampa Intl AP, FL,-US Winter Design Conditions Summer Design Conditions Outside db 40 OF Outside db 91 OF Inside db 70 OF Inside db 75 OF Design TD 30 OF Design TD 16 OF Daily range L Relative humidity 50 % Moisture difference 54 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 20520 Btuh Structure 23627 Btuh Ducts 6629 Btuh Ducts 8990 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (qonp) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 27149 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 32517 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 2674 Btuh Ducts 1469 Btuh Central.vent (0 cfm) 0 Btuh Heating Cooling (none) 26'5 Area(ft2) N 26M Equipment latent load 4144 Btuh Volume(ft3) 22094 22094 Air changes/hour 0.22 0.11 Equipment total load 36660 Btuh Equiv.AVF(cfm) 81 41 Req. total capacity at 0.75 SHR 3.6 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER Trade CARRIER Model CH14NB042****A Cond CH14NB042****A AHRI ref C611 FB4CNP042 AHRI ref Efficiency 8 HSPF Efficiency 11.3 EER, 13.7 SEER Heating input Sensible cooling 30750 Btuh Heating output 38500 Btuh @ 47OF Latent cooling 10250 Btuh Temperature rise 26 OF Total cooling 41000 Btuh Actual air flow 1367 cfm Actual air flow 1367 cfm Air flow factor 0.050 cfm/Btuh Air flow factor 0.042 cfm/Btuh Static pressure 0.56 in H2O Static pressure 0.56 in H2O Space thermostat Load sensible heat ratio 0.89 Capacity balance point=31 OF Backup: Input=9kW, Output=29290Btuh, 100AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrlghtsofV Right-Suite®Universal 2017 17.0.21 RSU25554 2017-Nov-11 12:56:20 Pa ...WrIghtsoft Files\Express horfies%Hayden­4EHB.rup Cale=MJ8 House faces: E ge 1 I • FORM R405-2014 i I i RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST Florida Department of Business and Professional Regulation Simulated Performance Alternative(Performance)Method Applications for compliance with the 2014 Florida Building Code, Energy Conservation via the residential Simulated Performance method shall include ❑ This checklist ❑ A Form R405 report that documents that the Proposed Design complies with Section R405.3 of the Florida Energy Code. This form shall include a summary page indicating home address, a-ratio and the pass or fail status along with summary areas and types of components, whether the home was simulated as a worst-case orientation, name and version of the compliance software tool, name of individual completing the compliance report(1 page)and an input summary checklist that can be used for field verification (usually 4 pages/may be greater). ❑ Energy Performance Level(EPL)Display Card(one page) ❑ Mandatory Requirements(three pages) Required prior to CO for the Performance Method: ❑ Air Barrier and Insulation Inspection Component Criteria checklist(Table R402.4.1.1 - one page) ❑ A completed Envelope Leakage Test Report(usually one page) ❑ If Form R405 duct leakage type indicates anything other than "default leakage", then a completed Form R405 Duct Leakage Test Report(usually one page) I • I I EnergyGauge@.-USRCZB v5.1 11/11/2017 1:00:03 PM Page 1 of 1 PASCO COUNTY DA DEVELOPMENT SERVICES JE-OUNTY FLOffl-is C DA 8731 Citizens Drive Date:8115/2018 j C '-y New Port Richey,FL 34654 727-847-2411 NOT A PERMIT Receipt#: 1785002 FEE DESCRIPTION ACCOUNT CODE UNITS INVOICE# FEE AMOUNT PAID RECEIPT# DATE Impact Fee Residential Solid 24503100-329010 23.96 1374871 $23.96 $23.96 1785002 8/15/18 Waste Single Family TOTALS: $23.66 $23.96 Receipt# Paid By Check# CC Auth# Cashier ID Workstation Receipt Date Amt Paid 1785002 Check 791242 540 BCCCP06W 08/15/2018 -$23.96 Total Payments- $23.96. Pavor Address Phone D R Horton 1341 Horton Circle Arlington TX 76011 Comments: Solid wast for City'of Zephy I s Address:6 05 Wagon Tr J treet Parcel:05 2" 21 008 600 0320 While you will be paying your bill with Pasco County Development services,the full amount of the credit card or e-check fees,NOT shown above,is collected by First Billing payment services. MyReports/reports//PASCOPROD/PASCO/RecelptPOS V6.rpt 8/15/2018 Page 1 of 1 5335 - 8TH STREET (813)780-0020 CERTIFICATE OF OCCUPANCY Address: 6605 WAGON TRAIL ST Owner: DR HORTON INC ZEPHYRHILLS, FL. 12602 TELECOM DR Subdiv: SILVERADO TEMPLE TERRACE FL 33637-0935 Parcel: 05-26-21-0080-00600-0320 Work Type: 101-NEW CONST/SFR Construction Type: NOT APPLICABLE ❑ Sprinklers Use Classification: NOT APPLICABLE Permit Number: 19589 Dat 10/17/2018 BUILDIW OFFICIAL ::' U WATER MUST BE CHANGED OVER WITHIN 10 DAYS OF ISSUANCE GARBAGE DEPOSIT MUST BE APPLIED FOR PRIOR TO ISSUANCE