Loading...
HomeMy WebLinkAbout18-19590 CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 19590 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL PERMIT INFORMATION - LOCATION INFORMATION Permit#:19590 Issued: 4/26/2018 Address: 6517 WAGON TRAIL ST Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 266,079.30 Total Fees: 11,394.69 Subdivision: SILVERADO Amount Paid: 11,394.69 Date Paid: 4/26/2018 Parcel Number: 05-26-21-0080-00600-0210 CONTRACTOR INFORMATION . OWNER INFORMATION Name: D R HORTON INC Name: DR HORTON INC Addr: 12602 TELECOM DR Address: 12602 TELECOM DR TAMPA, FL. 33637 TEMPLE TERRACE FL 33637-0935 Phone: Lic: Phone: 813-549-1968 Work Desc: CONSTRUCT SINGLE FAMILY HOME 2,362 SQ FT APPLICATION FEES BUILDING FEE 1,088.77 ELECTRICAL FEE 222.53 PLUMBING FEE 148.35 MECHANICAL FEE 103.85 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE-sfr/100% 4,828.00 SCHOOL IMPACT FEE-sfr/1% 48.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32 / yy/ � l Q.-:&-5' Inspections Required FOOTER 2ND ROUGH PLUMB Misc INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing, consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRACTORS SIGNATURE PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER i D R HORTON INC-6517 Wagon Trail-2,362 sq ft Column SO. FEET PRICE MAIN OR LIVING: 2,362 $ 112.65 OTHER AREA UNDER ROOF: - OTHER: - $ - VALUATION $ 266,079.30 FEE SHEET $ 989.00 ADDRESS $ 40.00 DRIVEWAY $ 40.00 BUILDING: $ 1,088.78 ELECTRICAL: $ 222.53 PLUMBING: $ 148.35 MECHANICAL: $ 103.85 SUB-TOTAL $ 1,563.50 TOTAL $ 1,563.50 SEWER: n/a WATER: n/a IRRIGATION: $ - TOTAL: $ - WATER METER: n/a IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 2,116.85 PARK IMPACT FEES $ 769.56 SIF'S: $ 4,828.00 100.0% $ 4,828.00 1.0% $ 48.28 TOTAL: $ 4,876.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 11,394.69 INSTR#2O18OG5719 OR BK 9711 PG 2264 Page 1 of 1 04/19/2018 10:54 AM Rcpt:1950010 Rec:10.00 DS:0.00 IT:0.00 Paura S.O'Neil P(1.D.,Pasco County-Clerk&Comptroller c Permit No. Parcel lDNo OS 2,IVvbV�OpG�O2�� �--�1 NOTICE OF COMMENCEMENT fT State of.--7 1 r l(�Q_. County of V r//1 Q 2 THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and In accordance wrath Cha ter 713.Florida Statutes, the following information is provided in this Notice of Comme cemept�I '� ,'vim / p 1. Description of Property: Parcel Identification No. �;��� (�[J / j tp C�/ Street Address: G.5 17 L Q1� l f u-, I � /- ZQA l/7��-4/ 33S�'( 2. General Description of Improvement Y t.Q -S l�(Q [e r a Vo rr I 3. Owner Information or Lessee information If the Lessee contracted for the improvement: T)- R-aac ', 1 u 02 " Q.I�rr,M r lntilpc.� t��t o Address City r State Interest in Property: _ .Pee S51M_0 Name of Fee Simple Titleholder. (If different from Owner listed above) Address T) n�r t r n 37A0 City r. State 4. Contractor ontracto p�1 J�00.1 1 ame re,�elAM r '� lMd�CZ 3J�c� >CL Address City r State Contractor's Teelephone No.: 5. Surety N Name' Address A' City State Amount of Bond: $ A Telephone No.: 6. Lender. Address City Slate Lender's Telephone No.: 7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)M,Florida Statutes: Name n // moo-7- Address �:4y_0 't State Telephone Number of Designated Person: �6.C2-!I 9 �/`7�( 8. In addition to himself,the owner designates ��/�/'7 of_ to receive a copy of the Llenor's Notice as provided in Section 713.13(1)(b),Florida Statutes. Telephone Number of Person or Entity Designated by Owner. 9. Expiration date of Notice of Commencement(the expiration date may not be before the completion of construction and final payment to the contractor,but will be one year from the date of recording unless a different dale is specified): WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE DCP(RATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalty of perjury,1 declare that 1 have read the foregoing notice of commencement and that the facts stated therein are true to the best of my knowledge and belief. STATE OF FLORIDA COUNTY OFPASCO S gna ure of Owner or Lessee,or Owner's or Lessee's Authorized Officer ireclor/Partner/Manager ASs -- - D-.� Signatory's TIitle1Office /gyp L The foregoing instrument was acknowledged before me/this� ,yda�y,pof KDCI 1 ,20�y 1�1 QG Ci 1, �I O ash f Y/r(b I W r/""CCC (type of authodty,e.g.,officer,trustee,attorney in fact)for 11 /qo f n Tn 0 (name of party on b al f who i IInnsttrrument was executed). Personally Known Lit OR Produced Identification Cl' Notary Signature Type of Identification Produced Name(Print) 17 NNotary Public State of Florida Michelle Moyes My Commtssion GG 057321 F�kes1221/2020 wpdata/bcslnoticecommencement pc053048 PASCO COUNTY DA DEVELOPMENT SERVICES Jul-6 C 8731 Citizens Drive Date:8/15/2018 COUNTY FLORIDA' Orin SlYCES.1/ffikriVt PIACI-S. New Part Richey,FL 34654 727-847-2411 NOT A PERMIT Receipt#: 17$4985 FEE-DESCRIPTION ACCOUNT CODE UNITS INVOICE# FEE AMOUNT PAID RECEIPT# DATE Impact Fee Residential Solid 24503100-329010 23.96 13748.50 $23.196 $23.96 1784985 8/15/18 i Waste Single Family TOTALS: $23.96 $23.96 Receipt# Paid By Check# CC Auth# Cashier ID Workstation Receipt Date Amt Paid 1784985 Check 791243 556 BCCCP35W 08115/2018 $23.96 Total Payments: $23.96 Pa or Address Phone d.r horton Comments: City of Zephyrhi" .d waste#105 Add 1. 517 wagon trail st. es Par re05 26 21 !!"' 00 0210 While you will b-e—p57rag'your bill with Pasco County Development Services,the full amount of the credit card or e-check fees,NOT shown above,Is collected by First Billing payment services. MyReports/reports//PASCOPROD/PASC0/ReceiptPOS_y6.rpt 8/15/2018 Page 1 of 1 i �. PASCO COUNTY, FLORIDA Permit No. 425�0 cj, Date Permitted —1 -Builder Name/Owner Name {t) Q tiJr � Control# County Parcel No, [} 2(0 2 t.0 OBP^b�(flpD-b z t b .SubDiv: �, ( r a Address/Location Oy+ �t(64s ( t Classitication(rype of Use 6 e t TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: Zt 3�rZ i Exempt []Yes ❑ No How Determined Impact Fee Amount Zone No. TAZ: SCHOOL IMPACT FEE '. Account (056) Single-Family Detached House Amount $ (057) Mobile Home ?' (056) Other Residential 123) Collection Fee Exempt n Yes ❑ No How Determined ' PARKS AND RECREATION FEE { Land Account Land Credit Land Total i Recreation Account Recreation Credit Recreation Total Zone TOTAL AMOUNT $ �torJ i Exempt ❑ Yes ❑ No How Determined LIBRARY FEE Land Account Land Credit Land Total Facility Account Facility Credit Facility Total Exempt ❑Yes ❑ Na How Determined Total Amaun RESOURCE FEE ERU TOTAL AMOUNT Prepared By Checked By v NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY r• Acknowledgement below does not imply acceptance of concurrence,but simply receipt of-a copy of this form,placing the building permit owner on notice of this assessment and the conditions of payment for same. DATE RECEIVED BY RECEIPT NO. DATE BY j 4 , 05-26-21-0080-00600-0210 Pasco County Property Appraiser Page 1 of 1 Data Current as Of: Weekly Archive - Monday, April 16, 2018 Parcel ID 05-26-21-0080-00600-0210 (Card: 001 of 001) Classification 00 - Vacant Residential Mailing Address Property Value DR HORTON INC Ag Land $0 12602 TELECOM DR Land $2,741 TEMPLE TERRACE FL 33637-0935 Building $0 Physical Address Extra Features $0 6517 WAGON TRAIL STREET ZEPHYRHILLS, FL 33541 Just Value $2,741 Legal Description (First 4 Lines) Assessed (Non-School Amendment 1) $2,741 j See Plat for this Subdivision Taxable Value $2,741 SILVERADO RANCH SUBDIVISION PHASES 6, 8 &9A PB 75 PG 075 BLOCK 6 LOT 21 Jurisdiction City of Zephyrhills _ Land Detail (Card: 001 of 001) Line _Use Description?Zoning Units Type ^Price ;Condition Value 1_ 0100 SFRMPUD 6,000.00 SF I $0.40 1.00 $2,400 2 0100 SFR I MPUDv 1,362.00 SF i` $0.25 1.00 $341 I Additional Land_ Information _ Acres 0.17 IITax Areal 30SI 7 Code ResideiMA ntial Code', SLVRCPI Building Information - Use 00 - Unimproved (Card: 001 of 001) Unimproved Parcel 00 - Unimproved _ Extra Features (Card: 001 of 001) _ Line _..__. 'DI escription�--1Year Units �Value No Extra Features Sales History = See All 6 sales Previous Owner: DUNE FL LAND I SUB LLC Month/Yea rjBook/Page ype�T --I�DO—R—Code ConditionAmount _ 04/201 Warranty Deed _1 05 Vacant Multi-Parcel Sale 05/2017 19535 / 0546 . Certificate of Title _ 05 _� Vacant Multi-Parcel Sale, 11/2016 19462 / 0384 }Mineral,Rights or Royalty Transfer! 05 Vacant Multi-Parcel Sale . I I http://search.pascopa.com/parcel.aspx?parcel=2126050080006000210 4/19/2018 813-780-0020 City of Zephyrhills Pe`mit Application Fax-813-780-0021 Building Department Date Received 0? • �� Phone Contact for Permitting Owner's Name . CS;^ -a, r-. Owner Phone Number f s-L/ c�7 fJ Owners Address Owner Phone Number L Fee Simple Titleholder Name Sri: Owner Phone Number Fee Simple Titleholder Aid-dress JOB ADDRESS n -{� LOT# .SUBDIVISION �� PARCELiD (OBTAINED FROM PROPERTY TAX NOTICE) ; W014K PROPOSED NEW CONSTR ADD/ALT SIGN Q DEMOLISH INSTALL_ 8 REPAIR PROPOSED USE Of SFR COMM OTHER TYPE OF CONSTRUCTION " ��� BLOCK 0 FRAME STEEL . DESCRIPTION OF WORK �''t />���G ��rill_ e. 6,-r I` )- BUILDING SIZE SQ FOOTAGE � HEIGHT 'T'e"rrx-r•v-i-r-s-'-Irr-rr -i-t"i-r-rmr�rrrr'r'r �r-r-Q-Ir�r-t-r�--e-r-' -re-s-I-a���-'e"e�t-c-4 a a-e-e-'a���'e-x� =BUILDING $ VALUATION OF TOTAL CONSTRUCTION 0ELECTRICAL Is AMP SERVICE -PROGRESS ENERGY W.R.E.C. , =PLUMBING $ i u � MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION . SUMO =GAS 0 ROOFING Q SPECIALTY OTHER FINISHED FLOOR ELEVATIONS ,� . FLOOD ZONE AREA DYES NO --4-6-4-i-�a-E-i•-ii-C-•i•-S--F-a-M1-C-i--i�4..r.-1'-�-'�-"1-��F-p--&-➢-•G-I-F-�-1-➢-I--l-'tea-v'�6�d�1--u�'-1--1�•6-'v-E-•➢-°v-:-6-a�s�4y$�um;'.sz�l•-4•-$-4'-➢-•d•-• BUILDER COMPANY r` - -)c) "t `c's''-� f 1 SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address %.� �� � '<i�.m r^ 1Grt� License# ELECTRICIAN �� ��-,/��- COMPANY4�6 SIGNATURE ," REGISTERED FEE CURREEN Y/N Address ,ate License# ( �• � r. r� PLUMBER COMPANY .SIGNATURE REGISTERED Y/ N FEE CURREN ^ sY�/_N,/,r � Address 7'��iQ�, F.�,�+ 'tl. iaf ` License# MECHANICAL COMPANY SIGNATURE f�-' "'� ---REGISTERED Y I N FEE CURAEN Y/N Address • J'702 License#' CAL-0,�?;5 6 15 OTHER. Y COMPANY t r SIGNATURE REGISTERED Y/ N FEE CURRER Y/N Address License# ---'� 1111liilililiilllilllilltlili111iii11111l111l1i ! lldll1ll18IB11 ➢ 1 ➢ ➢ 1 RESIDENTIAL Attach(2)Plot Plans; (2)sets of Building Plans; (1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten (10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Siit•Fence installed, Sanitary Facilities&1 dumpster;Site Work'Permit for subdivisions/large projects COMMERCIAL Attach (2)complete sets of Building Plans plus a Life Safety Page; (1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten (10)working days aftevsubmittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet'compliance SiGN PERMIT Attach (2)sets of.Engineered Plans. "PROPERTY-SURVEY required for all NEW construction. •f-8.-6.-1.-8�.4-0-.•b-l--t•-f-1�-1•.•1-I--{_i�sa--1-tS-1-E•.i.-1-.S-d--1'-C.-S.-E-.l-.d-.6-b-,1-1!•--➢-�-i-•9..•A-.➢ •&-4•-6.�•-9e6--0-9�.1�.�..&-➢-E.-A.mll..�.-Im.➢�•�-5-.1i-�..8..5�6..• � Directions: Fill out application completely. Owner�Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500) ** Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized.letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles " Sewers Service Upgrades A/C Fences (Plot/Survey/Footage) Driveways-Nat over Counter if on public roadways..needs ROW / ` . . . ` NOTICE OF DEED RESTRICTIONS: TheundersiQnedundenstandstholthkspernitnaybesub^eotto deed" restrictions". which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CO0TRACTCR REGPONSIB|UTlES� If the owner has hired a contractor or uontnaotomtounde�ake work, they may bero iredtobe |ioenaadineccordoncew|thetadaand \oca| rogu|etinna. |fthe contractor is not-licensed as required by (aw, both the owner and contractor may be cited fora miadaineanorvio|atinn under state law. If the owner or intended-contractor are uncertain as to what licensing requirements may app|yfor'the intended work, they are advised to contact the-Pasco County Building Inspection Division—Licensing GaoUon st727-847- 8009. Furthermooe, if the owner has hired e contractor or contractors. he is advised to have the contractor(s) oign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign � th� contractor, that may be an indication that he is not properly licensed and is not entitled tb permitting privileges.in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned.understands that Transportation Impact Fees and Recourse Recovery,Fees may apply to the construction of new buildings, change of use in existing bVUd|nga, or expansion of existing bu||dings, as specified in Pasco County Ordinance number 89-07 and 90'07. as amended. The undersigned a|so unde[standS, that such fees. as may be dUo, will be identified at the time of permitting. \t \ofurther understood that Transportation innpont Fees and Resource Recovery Feasnnuatbo paid prior to receiving o "certificate uf occupancy" or final power release. |f the project does not involve a certificate of occupancy or final power release, thm faao must be paid prior to permit issuance. Furthermore, if Pasco-County Water/Sewer Impact fees are due,they must be paid prior to permit issuance |naccordance vvith applicable Pasco County ordinances. CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of Work is $2.500.b0 or more, | certify that i, the applicant, have been provided with a copy of the "Florida Construction, Lien Law—Homeowner's Protection Guide" prepared by the F|ohda Department of Agriculture.and Consumer Affairs. If the applicant is someone` other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver itto the^owner' priortocommencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: | certify that all the information in this application is accurate and that all work will be done in compliance with all applicable |awo regulating construction, zoning and land development. Application is � hereby made to,obtain a permit to do work and installation as indicated. | certify that no work or installation has commenced prior to issuance of permit and that all work will be performed to. meet standards of all laws regulating conetnuobon. County and City codes,' zoning regulations, and land development regulations. in the jurisdiction. | also certify that | understand that the regulations ofothe'r government aQenC\ma may a. ppk/to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental P rote ntion-Cypress Beyheads. VVet|ondAreas and Environmentally Sensitive � Lands,Water/Wastewater Treatment. ^ - Southwest Florida Water Management D\strict-VVaUs. Cypress. Bayhoado, Wetland Areas, Altering Watercourses. . - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. ' - Department of Health & Rehabilitative Servioea/Environmental Health Unit-Wells, Wastewater Treatment,'. Septic Tanks. ` - US-Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authnrity+Runvvaye. | understand that the following restrictions apply to the use offill: - Use of fill io not allowed io Flood Zone"V"' unless expressly porrnittad` - |f the fill material is to be used in -Flood Zone ''A''. it is understood that a drainage -plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State VfFlorida. ' If the fill no material a\ is to be used in Flood Zone ^ in connection wit a permitted building using stern vvaU construction, I certify that fill will be used only to fill the area within the stem wall. - U fill material is to be used in any area, | certify that use of such fill will not adversely affect adjacent . properties. If us.a of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for (uta |eaa than one /1\ acre which are elevated by fill, an engineered drainage plan iarequired. _ |f | am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction.. | understand that a a6para1e permit may be.required for.electrical work, p|umbing, signs, wells, pools, air conditioning, gao, or other installations not specifically included in the application. & permit issued shall be consthued to be a license to proceed with-the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall iaouanceofa permit prevent the Building Official from th�res��r requNngaoonen��nof errors-in plans, oonatnuc�onorvio(ad U onsofanycodeo. Every permit invalid un|ona,the work authorized by such permit is unnnnnenosd within six months of permit |aauanoe, or if work authorized'by th8permitiasUapendodor *bondonedfbrapariod'ofa\u (6) monthaafterthe time the Work \ocommenced. An extension may be requested, in-writing, from the Building Official for a period not to exceed ninety /QO\ d�ya� and will demonstrate ` justifiable cause for the extension, |f work oeaoes-for ninety /8O\ consecutive d8yo.�the 'job 'a considered abandoned. ` WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE ��F COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. \F YOU INTEND TOOBTAIN FlY0A0CJIY8G, COY0SOLTWITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT., FLORIDAJUR ' A `F_ 117— , OWNER OR ouosnn000 and no (or affirmed) Subscribed and sworn to(or by . Who is/are personally known mmeorhas/have produceda—si ' ------- identification. ' ' �Notary Pubfic� Notary Public Notary Public ` . ` « Co=" "o'No. Commission ' Name of Notary typed,printed or stamped Name of Notary_ typed,'—_-_ stamped_ State of Florida F,11% Notary Public ML OF iv Expire$12/21/2020 This Instrument Was Prepared By And Should Be Returned To: Lee E.Nelson,Esq. Shutts&Bowen LLP 4301 W.Boy Scout Blvd.,Suite 300 Tampa,Florida 33607 Tax Identification Nos.: 04-26-21-0070-00100-0200;05-26-21-0080-00600-0210; 05-26-21-0080-00600-0250;05-26-21-0080-00600-0260; 05-26-21-0080-00600-0270;05-26-21-0080-00600-0280; 05-26-21-0080-00600-0310;05-26-21-0080-00600-0320 SPECIAL WARRANTY DEED This Special Warranty Deed(this"Deed"), executed as of the day of 2018, by DUNE FL LAND I SUB LLC, a Delaware limited liability company C Grantor"), whose mailing address is 2502 N. Rocky Point Drive, Suite 1050, Tampa,Florida 33607,to D.R. HORTON, INC., a Delaware corporation ("Grantee"), whose mailing address is 12602 Telecom Drive,Tampa,Florida 33637. WITNESSETH: That Grantor, for and in consideration of the sum of ten dollars ($10.00) and other good and valuable consideration to Grantor in hand paid by Grantee, the receipt and sufficiency of which is hereby acknowledged, has granted, bargained, and sold to Grantee and Grantee's successors and assigns forever, the real property situate, lying, and being in Pasco County, Florida,and described in EXHIBIT A attached hereto and made a part hereof(the"Property"). TOGETHER with all of the Grantor's rights, title and interest in and to all licenses, approvals,tenements,hereditaments, and appurtenances belonging or in any way appertaining to the Property. TO HAVE AND TO HOLD the same in fee simple forever. And Grantor hereby specially covenants with Grantee that Grantor is lawfully seized of the Property in fee simple, and hereby specially warrants the title to the Property and will defend the same against the lawful claims of all persons claiming by, through or under Grantor,but not otherwise, and that the Property is being conveyed to Grantee subject to those permitted exceptions identified in EXHIBIT B attached hereto and made a part hereof, provided the foregoing shall not serve to reimpose the same. [SIGNATURE ON NEXT PAGE] i EXHIBIT A . Legal Description Lot 20, Block 1, of SILVERADO RANCH SUBDIVISION PHASES 2, 3 &4, according to the Plat thereof, as recorded in Plat Book 73, Pages 59 through 65, inclusive, of the Public Records of Pasco County,Florida. AND Lots 21,25,26, 27, 28, 31 and 32, Block 6, of SILVERADO RANCH SUBDIVISION PHASES 6, 8 & 9A, according to the Plat thereof, as recorded in Plat Book 75, Pages 75 through 80, inclusive, of the Public Records of Pasco County,Florida. EXHIBIT B Permitted Exceptions 1. Taxes and assessments for the year 2018 and subsequent years,which are not yet due and payable. 2. Restrictions, dedications, conditions, reservations, easements and other matters shown on the plat of SILVERADO RANCH SUBDIVISION PHASES 2, 3 & 4, as recorded in Plat Book 73, Pages 59 through 65, inclusive, of the Public Records of Pasco County, Florida (as to Lot 20, Block 1). 3. Restrictions, dedications, conditions, reservations, easements and other matters shown on the plat of Silverado Ranch Subdivision Phases 6, 8 & 9A, as recorded in Plat Book 75, Pages 75 through 80, inclusive, of the Public Records of Pasco County, Florida (as to Lots in Phases 6, 8 &9A). 4. Declaration of Covenants, Conditions and Restrictions, including any amendments or modifications thereto, recorded in Official Records Book 9443,Page 1105, of the Public Records of Pasco County, Florida. 5. Notice of Establishment of the Silverado Community Development District recorded in Official Records Book 9135, Page 1403; Ordinance No. 1241-14 recorded in Official Records Book 9123, Page 3 and re-recorded in Official Records Book 9179, Page 3371 and re-recorded in Official Records Book 9399, Page 2667, all of the Public Records of Pasco County, Florida. 6. Ordinance No. 1247-15 recorded in Official Records Book 9170, Page 87, amended by Ordinance No. 1326-17 recorded in Official Records Book 9551, Page 45, both of the Public Records of Pasco County, Florida. 7. Terms and conditions of the Declaration of Consent to Jurisdiction of the Silverado Community Development District, Imposition of Special Assessments, and Imposition of Lien of Record recorded in Official Records Book 9388, Page 227, of the Public Records of Pasco County,Florida. 8. Terms and conditions of that certain Lien of Record, Disclosure of Public Financing, and Maintenance of Improvements of the Silverado Community Development District (Series 2016A-1 Bonds) recorded in Official Records Book 9388, Page 241, of the Public Records of Pasco County,Florida. 9. Terms and conditions of that certain Lien of Record, Disclosure of Public Financing, and Maintenance of Improvements of the Silverado Community Development District (Series 2016A-2 Bonds) recorded in Official Records Book 9388, Page 246, of the Public Records of Pasco County,Florida. 10. Terms and conditions of that certain Subdivider's Agreement recorded in Book 9401, Page 1466. As to Phases 2, 3, &4. 11. Terms and conditions of that certain Subdivider's Agreement recorded in Book 9618, Page 2844. As to Phases 6, 8 &9A. 12. Declaration of Consent to Jurisdiction of the Silverado Community Development District, Imposition of Special Assessments, and Imposition of Lien of Record as recorded in Book 9598,Page 3122,of the Public Records of Pasco County, Florida. 13. Any lien or right to a lien for labor, services or materials provided in connection with the construction of the improvements referred to in the Notice of Commencement filed December 21,2017 in Book 9652,Page 2419,of the Public Records of Pasco County, Florida, as to Lot 20, Block 1. TPADOCS 22002716128053.0168 i D. R. Horton-6517 Wagon Trail-2,362 sq ft Column Es SQ. FEET PRICE MAIN OR LIVING: 2,362 $ 112.65 OTHER AREA UNDER ROOF: $ 88.00 OTHER: - $ - VALUATION $ 266,079.30 FEE SHEET $ 989.00 ADDRESS $ 40.00 DRIVEWAY1 $ 40.00 BUILDING: $ 1,088.78 ELECTRICAL: $ 222.53 PLUMBING: $ 148.35 MECHANICAL: $ 103.85 SUB-TOTAL $ 1,563.50 TOTAL $ 1,563.50 SEWER: n/a WATER: n/a IRRIGATION: $ - TOTAL: $ - WATER METER: n/a IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 2,116.85 PARK IMPACT FEES $ 769.56 SIF'S: $ 4,828.00 100.0% $ 4,828.00 1.0% $ 48.28 TOTAL: $ 4,876.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 11,394.69 I /�� IA:afl1Ufl' City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: i� Date Received: Site: 5 (7 i 'L Permit Type: f I� r Z 3�aZ-S3--Y-t� i Approved Who comments:❑ Approved w/the below comments: Denied w/the below comments: ❑ This comment sheet shall be kept with the permit and/or plans. l Kalv' Sw�iize —Plans Examiner Date Contractor and/or Homeowner y (Required when comments are present) Single Family.Dwelling - Plan Review.Comments: : . 1. RKE. shall be a minirnum:of 8"_above.the road.elevation and an engineered site plan. 2. Lots shall be graded"to.comply with R401.3 of the F.B;C: 3. Compaction festrequired.if 24" or more of-fill dirt is.brought.in:at any one place: 4:: -Tie in survey required before pouring concrete.. 5. . Driveways-require a R.O:W. use permit: All 4 sides of driveway.thru the sidewalk shall have expansion material:. '6.. All setbacks shall be inet.:. .7. All.property.markers shall be,uricovered and marked.at time of first.inspection: 8:- :All A.D.A.-requirements shall'be met.: 9- No:electric,plumbing,mechanical;,or-framing shall be covered without an inspection.and approval first. . .. 10.All Garages shall comply with:section R302:6:of the F.B.C;: (Fire Separation).. 11:Appliances.sha. not:be installed in:a location where subject to mechanical damage unless protected by approved barriers. M303.4 of the F.B.C. 12. Water heaters shall 3 comply with section.P607. of the F.B.C: 13. Foundation supports for.A/C units.shall be raised at-least 3" above finished grade..' M1308.1 l4. Return air in all:bedrooms.,F.B.C. .M1620.4.: 15: Smoke detectors are to be:installed.in accordance with.R313:.1 of the F.B.C. " 16.:All glazing requirements are to be in accordance with R308.4.of the F.B.C. 17. All means,of egress are to:be in accordance with R311:of the RB.G., 18. `.`Green gypsum..board"shall not'be-used:as.a backer in.showers'or tubs:R702.4:2.F.B.C. 19. Combination-type'AFCI breakers are-required,at all.locations requiring=an.AFCI.type breaker. . 20: Carbon monoxide alarms will-be required in new.construction-that uses fossil-burning heating or appliances or an attached garage.:.They shall be.installed in accordance with.tlie F.B.C.. 2 L'All plumbing;mechanical,.and electrical shall-lie separate from unit,to:unit: This:-includes all Underground plumbing acid electric. 22. All 2011 N.E:C: Codes-wili.be enforced: 23:Tamper- Resistant Receptacles in accordance i ith 406.11. of the 2011 N:E:C. .24: In accordance..with.the Land:Development:Code, lots.shall be,sodded before final of least 10 feet-around the structure: 25.A copy of the eneryy cacls shall be with permitat all times 26. Copy of rnal insulation report shall be.provided with.permit-before.riza F.F.E.-Finished Floor Elevation F.B:C-Florida Building Code 6t'Edition R.O.W.-Right of Way A.D:A.-Americans with Disabilities Act . N.E.C:-National Electric Code (2011). . PLOT PLAN DESCRIPTION:,(AS FURNISHED) LOT 21, BLOCK 6, SILVERADO RANCH SUBDIVISION PHASE 6, 8 & 9A AS RECORDED IN PLAT BOOK 75, PAGE(S) 75-80, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. as.. ON LOT CAL CULATIONS LOT = 7,361 SQ. FT. LIVING AREA = 1,828 GARAGE = 430 SQ. FT. SO. FT. 60, ENTRY = 16 SO FT. LANAI = 88 K. FT. PATIO = 0 SO. FT. DRIVEWAY 453 SO. FT. 21 A/C PAD = 12 SQ, FT. WALKWAY = 28 SQ. FT. IMPERVIOUS = 39% = 2855 SQ. FT. SOD = 4,506 SQ. FT. OFF LOT CALCULATIONS RP RIGHT OF WAY = 376 so. FT. DRIVE APRON = 51 SQ. FT. PUBLIC S/W = 251 SO. FT. SOD = 74 SO. FT. TOTALS 105.13 AREA = 7.737 SO. FT. DRIVEWAY = 504 SQ. FT. SIDEWALK = 279 SO. FT. 0. SOD = 4,580 SO. FT. 'Z �''(o F" PROPOSED INLET Curve Toble 00. NOT FIELD LOCATED Curve#I Length I Rc '9 . ....... d I I I Chord 88cring Ch.rd C1 I 12.6r 1 50.00' F--1-8-r 7 F2 55.1 tK Op )0* 14-30`55* F,3,1'43'07'E 12,13' )0' 40*48'42* S46*52-OD-E 38.35' 0 00. 106.1 ry rczn,. 0) o II >i co '0 AD (IV 105.9 41" o. /' A- m (j .30' %'J6-, c"f- - GRAPHIC SCALE /V� 0, / 0 115 30 LO PREPARED FOR: 04f A-HORTONIhO n_ * �RF BUILDING SETBACKS FLOOD ZONE'X FRONT- 20' FLOOD ZONE "AE" REAR: O� (BFE 103.4) S DE: 15' 7.5' SIDE STREET: 20' LEGEND: NOTES: BUILDING SETBACK LINE Pf POINT OF INTERSECTION 1. ELEVATIONS SHOWN ARE PER LOT GRADING CENTERUNE PC POINT OF CURVATURE RIGHT OF WAY LINE RP RADIUS POINT PLANS PROVIDED BY THE CLIENT. PT POINT OF TANGENCY 2. ELEVATIONS ARE BASED ON NAVD 1988 PROPOSED ELEVATION PRC POINT OF REVERSE CURVATURE DATUM. PCC POINT OF COMPOUND CURVATURE TYP PROPOSED DRAINAGE FLOW GS CONTYPICALCRETE SLAB THIS PLOT PLAN IS INTENDED FOR PERMITTING PURPOSES (P) PER PLAT ONLY. THIS IS NOT INTENDED FOR THE CONSTRUCTION OF CONCRETE CALCULATED THE PROPOSED HOUSE, REFER TO HOUSE PLAN AND A/C AIR CONDITIONER 'C"P, PLAT BOOK OPTION LIST FOR CONSTRUCTION. ALL BUILDING SET BACK- S/W SIDE)VALK PGS PAGES SQ.FT. SQUARE FEET LINES SHOWN HEREON IS PER DATA FURNISHED BY CLIENT F.E.M.A, FEDERAL EMERGENCY MANAGEMENT AGENCY AND IS FOR INFORMATIONAL PURPOSES ONLY. F.I.R.M. FLOOD INSURANCE RATE MAP NAVD NORTH AMERICAN VERTICAL DATUM THIS IS NOT A SURVEY NGVD NATIONAL GEODETIC VERTICAL DATUM D&UE DRAINAGE&UTILITY EASEMENT THIS IS A PLOT PLAN 0 PDE PRIVATE DRAINAGE EASEMENT !F,LOOD,NOTE, , ONLY UE UTILITY EASEMENT(PUBLIC) ,VE IAMIN,D THE F.I.R.M. MAP NO. 12101CO2816F, SURVEYOR NOTES: DATED SEPTEMBER 26, 2014.AND FOUND THE SUBJECT PROPERTY 1. THE SURVEYOR HAS NOT ABSTRACTED THE APPEARS TO UE IN ZONE"X'. AREAS DETERMINED TO BE OUTSIDE THE LAND SHOWN HEREON FOR-EASEMENTS, RIGHT 0.2%ANNUAL CHANCE FLOODPLAIN AND ZONE-AE-, BASE FLOOD OF WAY, RESTRICTIONS OF RECORD WHICH ELEVATION 103.4. THE SURVEYOR MAKES NO GUARANTEES AS TO THE MAY AFFECT THE TITLE OR USE OF THE LAND. I ABOVE INFORMATION.PLEASE CONTACT THE LOCAL F.E.M.A. AGENT FOR VERIFICATION. 2. NO UNDERGROUND IMPROVEMENTS HAVE BEEN !I BEARING BASIS: LOCATED EXCEPT AS SHOWN. BEARINGS SHOWN HEREON ARE BASED ON THE CENTERLINE OF WAGON 3. NOT VALID WITHOUT THE AUTHENTIC TRAIL STREET BEING N53*35'22"W,PER PLAT. ELECTRONIC SIGNATURE-AND THE AUTHENTIC (FIELD DATE:) REVISED: F ELECTRONIC SEAL OF A FLORIDA LICENSED SURVEYOR AND MAPPER. SCALE: 30 FEET ZS U F:;,: \'/F= )r Digitally ignedbyjamesw 1;Bol— xt 0. - APPROVED BY: jB 8c MAPPING INC- f, '.�. 11 9-A—imn So mes eying&Mapping, I Af J, e. CERTIFICATION OF AUTHORIZATION NUMBER UB#6393 th- 171013 LOT 21, BLK 6 3191 MAGUIRE BOULEVARD, SUITE 200 JOB NO. ema'Fl-jbqfman@wmcorporatexo FOR ORLANDO. FLORIDA 32803 oat �-us THE DRAWN BY-, DSB (467) 426-7979 W�_Z� Dat.2017.11.16 09-30r.00_05_ a PLOT PLAN 11/10/17 KJW WWW.AMERICANSURVEYINGANDMAPPING.COM JAMES W. BOLEMAN PSM# 6485 DATE I FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Cali 1828 Elev C SiBuilder Name: DRH Express Homes / c Street: 61� 00L rtq� J Permit Office: f a City,State,Zip: Zephyrhills,FL,�-1. -1) Permit Number: ��p Owner: \ Jurisdiction: G f t&0a Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1710.2 sgft.) Insulation Area 2:-Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1404.00 ft2 b.Frame-Wood,Adjacent R=11.0 306.22 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 10.Ceiling Types (1828.0 sgft.) Insulation Area 5. Is this a worst case? No a.Under Attic(Vented) R=30.0 1828.00 ft2 6. Conditioned floor area above grade(ft2) 1828 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 11. Duct c. R= ft2 s R ft2 7. Windows(166.5 sgft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 356 a. U-Factor: Dbl, U=0.34 126.50 ft2 SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.55 40.00 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.34 a.Central Unit 28.6 SEER:14.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 28.6 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 2.722 ft. Area Weighted Average SHGC: 0.317 14.Hot water systems 8. Floor Types (1828.0 sg a.Electric Cap:50 gallonsft.) Insulation Area EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1828.00 ft2 b. Conservation features b.N/A R= ft2 None c.NIA R= ft2 15.Credits Pstat Total Proposed Modified Loads: 61.51 PASS SS Glass/Floor Area: 0.091 Total Baseline Loads: 61.25 I hereby certify that the plans and specifications covered by Review of the plans and 0 �famE S �Tfi this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: cities• Before construction is completed DATE: this building will be inspected for ... compliance with Section 553.908 I hereby certify that this building, as designed,is in compliance Florida Statutes. �S with.the Florida Energy Code. / GODi tg� OWNER/AGENTx%� BUILDING FFICIAL: L DATE: DATE: f - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. - Compliance With a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with Section 803 of RESNET Standards, is not greater than 0.060 Qn for whole house. 1 1/9/201 7 1 0:58 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 I FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of--Business and Professional Regulation - Residential-Performance Method' Project Name: Cali 1828 Elev C Builder Name: DRH Express Homes Street: 0- a- ,/! �[=1,J J 1 Permit Office: City,State,Zip: Zephyrhills, FL, c i 1 4 Permit Number: Owner: - I r ( � Jurisdiction: Design Location: FL,Tampa IZ\11 County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1710.2 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insui,Exterior R=4.1 1404.00 ft2 b. Frame-Wood,Adjacent R=11.0 306.22 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number.of Bedrooms 4 d.N/A R= ft2 10.Ceiling Types (1828.0 sqft,) Insulation Area 5. Is this a worst case? No a.Under Attic(Vented) R=30.0 1828.00 ft2 6. Conditioned floor area above grade(ft2) 1828 b.N/A- R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11. Ducts R ft2 7. Windows(166.5 sqft.) Description Area a.Sup:Attic, Ret:Main,AH:Main 6 356 a. U-Factor: Dbl,U=0.34 126.50 ft2 SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.55 40.00 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.34 a.Central Unit 28.6 SEER:14.00 c. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 28.6 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 2.722 ft. Area Weighted Average SHGC: 0.317 14. Hot water systems B. Floor Types (1828.0 sg a.Electric Cap:50 gallons ft.) Insulation Area EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1828.00 ft2 b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat ���� Glass/Floor Area: 0.091 Total Proposed Modified Loads: 61.51 Total Baseline Loads: 61.25 I hereby certify that the plans and specifications covered by Review of the plans and T%ES. this calculation are in compliance with the Florida Energy specifications covered by this , O Code. calculation indicates compliance ��v,;, %s "4z . with the Florida Energy Code. PREPARED BY: 1,1& ,�,,;., Before construction is completed DATE: n-g-n this buildingwill be inspected for - � - ,Cf p � 1 a . compliance with Section 553.908 I hereby-certify that this building, as designed,is in compliance Florida Statutes. - ' S� with the Florida Energy Code.. 1117WE OWNER/AGENT,�- 1pl BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. - -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with Section 803 of RESNET Standards, is not greater than 0.060 Qn for whole house. 11/9/2017 10:58 AM EnergyGauge@ USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 FORM R405-9014 PROJECT ' Title: Cali 1828 Elev C Bedrooms: 4 Address Type: Lot Information Building Type: User Conditioned Area: 1828 Lot# 21/6 Owner: Total Stories: 1 Block%SubDivision: Silverado Ranch #of Units: 1 Worst Case: No PlatBook: Builder Name: DRH Express Homes Rotate Angle: 45 Street: Permit Office: Cross Ventilation: County: Pasco Jurisdiction: Whole House Fan: City,State,Zip: Zephyrhills, Family Type: Single-family FL, New/Existing: New(From Plaps) Comment: Garage R Face NE CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Tampa FL_TAMPA_INTERNATI 2 39 91 70 75 645.5 54 Medium BLOCKS Number Name Area Volume 1 Blockl 1828 15848.8 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1828 15848.8 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio Main 198.6 ft 0 1828 ft2 ---- 0 0.25 0.75 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 2044 ft2 0 ft2 Dark 0.92 No 0.9 No 0 26.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 1828 ft2 Y N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) Main 30 Blown 1828 ft2 0.11 Wood i 1 1/9/201 7 1 0:58 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 4 I FORM R405=2014 WALLS Adjacent S# r)Mt To Wall Typepace Cavity Width Height Sheathing Framing Solar Below 1 N=>NE Exterior Concrete Block-Int Insul ' Main 4.0999 19 8 8 164.7 ft2 .0 0.6 0 2 W=>NW Exterior Concrete Block-Int Insul Main 4.0999 43 8 8 8 378.4 ft2 0 0.6 0 3 S=>SW Exterior Concrete Block-Int Insul Main :4.0999 39 8 8 8 343.8 ft2 0 0.6 0 4 E=>SE Exterior Concrete Block-Int Insul Main 4.0999 59 8 8 8 517.1 ft2 0 0.6 0 5 N=>NE Garage Frame-Wood Main 11 20 0 8 8 173.3 ft2 0.23 0.01 0 _6 W=>NW Garage Frame-Wood Main 11 15 4 8 8' 132.9 ft2 0.23 0.01 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N=>NE Insulated Main None .4 3 6 8 20 ft2 2 N=>NE Wood Main None .46 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered orientation => changed to As Built rotated 45 degrees). Wall Overhang # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N=>NE 1 Vinyl Low-E Double Yes 0.34 0.31 31.0 ft2 1 ft 0 in 4 ft 1 in Drapes/blinds Exterior 5 2 N=>NE 1 Vinyl Low-E Double Yes 0.34 0.31 2.5 ft2 3 ft 8 in 0 ft 0 in Drapes/blinds Exterior 5 3 W=>NW 2 Vinyl Low-E Double Yes 0.34 0.31 15.5 ft2 1 ft 0 in 0 ft 9 in Drapes/blinds Exterior 5 4 S=>SW 3 Vinyl Low-E Double Yes 0.34 0.31 62.0 ft2 1 ft 0 in 0 ft 9 in Drapes/blinds Exterior 5 5 S=>SW 3 Metal Low-E Double Yes 0.55 0.34 40.0 ft2 8 ft 0 in 0 ft 8 in Drapes/blinds Exterior 5 6 E=>SE 4 Vinyl Low-E Double Yes 0.34 0.31 15.5 ft2 1 ft 0 in 0 ft 9 in Drapes/blinds Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall,Perimeter Avg.Wall Height Exposed Wall Insulation 1 430.0128 ft2 430.0128 ft2 46.6 ft 8.67 ft 0 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000386 1849_ 101.51 190.9 .2892 7. HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump None HSPF:8.2 28.6 kBtu/hr 1 sys#1 I 11/9/2017 10:58.AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 4 FORM R405-2014 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit None SEER:_1, 28.6 kBtu/hr 858 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 50 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model#• Collector Model# Area Volume FEF None None ftz DUCTS ----Supply---- ----Return---- Air CFM 25 CFM25 HVAC# # Location R-Value Area Location Area 'Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 356 ftz Main 40 ft2 Proposed Qn Main ---cfm '109,7 0b 0.66 0.80 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: CoolingJan Feb Mar Apr _ Ma Jun Jul Auge Oct Nov Dec Heatin Jan f X}Feb Mar Apr f May f Jun f Jul f Auf Sep E Oct Nov Dec Vent!n Jan [ ]Feb Mar Apr l May [ Jun [ Jul [ Aug [ Se [X]Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11- 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 _ 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 1 1/9/201 7 1 0:58 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 4 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerformance Index,the more efficient the home. Zephyrhills, FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1404.00 ftz b.Frame-Wood,Adjacent R=11.0 306.22 ftz 3. Number of units,if multiple family 1 c.N/A R= ftz 4. Number of Bedrooms 4 d.N/A R= ftz 5. Is this a worst case? No 10.Ceiling Types Insulation Area a.Under Attic(Vented) R=30.0 1828.00 ft2 6. Conditioned floor area(ftz) 1828 b.N/A R= ftz _ z 7. Windows" Description Area 11 cDucts R R ftz a. U Factor: Dbl,U=0.34 126.50 ftz a.Sup:Attic,Ret:Main,AH:Main 6 356 SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.55 40.00 ftz SHGC: SHGC=0.34 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ftz a.Central Unit 28.6 SEER:14.00 SHGC: d. U-Factor: N/A ftz 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 28.6 HSPF:8.20 Area Weighted Average Overhang Depth: 2.722 ft. Area Weighted Average SHGC: 0.317 8. Floor Types Insulation Area - 14.Hot water systems a.Slab-On-Grade Edge Insulation R=0.0 1828.00 ftz a.Electric Cap:50 gallons EF:0.95 b.N/A R= ftz c.N/A R= ftz b. Conservation features None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for BuildinggE ST Construction through the above energy saving features which will be installed (or exceeded) w0� in this home before final inspection. Otherwise, a new EPL Display Card will be completed �;v.`,,,,''f�' e^ based on installed Code compliant features. a Builder Signature: Date: Address of New Home: , (' I f City/FL Zip: 7-r - - J L caD � Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 11/9/2017 10:58 AM EnergyGauge@ USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 . Florida Department of Business and Professional Regulations Residential Whole Building Performance and Prescriptive Methods ADDRESS: Permit Number: Zephyrhills,FL, MANDATORY REQUIREMENTS See individual code sections for full details. ❑ 401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law (Section 553.9085, Florida Statues]requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix C. ❑ R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.1 through R402.4.4. O R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.The sealing methods between dissimilar materials shall allow for differential expansion and contraction. • R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table 402.4.1.1,as applicable to the method of construction. Where required by the code official,an approved third party shall inspect all components and verify compliance. • R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2,and 3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3.Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. O R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers and outdoor combustion air. i O R402.4.3 Fenestration air leakage.Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400 or AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. O R402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential.All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. ❑ R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. ❑ R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. ❑ R403.2.2 Sealing(Mandatory)AII ducts,air handlers,and filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post-construction or rough-in testing below. Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either an energy rater certified in accordance with Section 553.99,Florida Statutes,or as authorized by Florida Statutes,to be"substantially leak free"by either of the following: 1. Post-construction test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure.All register boots shall be taped or otherwise sealed during the test. 2. Rough-in test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g. (25Pa)across the system,including the manufacturer's.air handler enclosure.All registers shall be taped or otherwise sealed during the test.If the air handler is not installed at the time of the test,total leakage shall be less than or equal to 3 cfm (85 Umin)per 100 square feet(9.29 m2)of conditioned floor area. Exceptions: 1. The total leakage test is not required for ducts and air handlers located entirely within.the building envelope. 2. Duct testing.is not mandatory for buildings complying by Section R405 of this code. 1 1/9/201 7 1 0:58 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Com Page 1 of 3 FORM R4C5-2014 MANDATORY REQUIREMENTS - (Continued) ❑ R403.2.3 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. ❑ R403.3 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C) or below 55°F(13°C)shall be insulated to a minimum of R-3., R403.3.1 Protection of piping insulation. ❑ R403.4.1 Circulating hot water systems(Mandatory). Circulating hot water systems shall be provided with an automatic or readily accessible manual switch that can turn off the hot-water circulating pump when the system is not in use. ❑ R403.4.3 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3 1/2 inches(89 mm)in the hot-water distribution line and cold water line located as close as possible to the storage tank. ❑ R403.4.4 Water heater efficiencies(Mandatory). 0 R403.4.4.1 Storage water heater temperature controls R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature setting range shall be from 100°F to 140°F(38°C to 60°C). R403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s) of combustion types of service water heating systems to be turned off. 0 R403.4.4.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1. R403.4.4.2.1 Solar water heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9306,Test Methods for Solar Collectors, and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol,Collectors in installed solar water heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and 2. Be installed at an orientation within 45 degrees of true south. ❑ R403.5 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code,Residential or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. ❑ R403.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment. 0 R403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1.This code does not allow designer safety factors,provisions for future expansion or other factors which affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load,but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.6,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load. 11/9/2017 10:58 AM EnergyGauge@ USA-FlaRes2014 Section R405.4.1 Cam Page 2 of 3 FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) 0 R403.6.1.1 Cooling equipment capacity.(continued) The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacture's expanded performance data shall be used to select cooling-only equipment.This selection shall be used to select cooling-only equipment.This selection_shall be based on the outdoor design dry bulb temperature for the load calculation(or entering water temperature for water-source equiPrnent),the blower cfm provided by the expanded performance data, the design value for entering wet bulb temperature and the design value for entering dry bulb temperature. Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space. Exceptions: 1. Attached single-and multi-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida-registered engineer,in attached single-and multi-family units,the capacity of equipment may be sized in accordance with good design practice. 0 R403.6.1.2 Heating equipment capacity • R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section R403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load. • R403.6.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.6.1. • R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.6.1. 0 R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. ❑ R403.7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the Commercial Provisions in lieu of Section R403. ❑ R403.8 Snow melt system controls(Mandatory). Snow and ice-melting systems,supplied through energy service to the building,shall include automatic controls capable of shutting off the system when the pavement temperature is above 55°F,and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F. ❑ R403.9 Swimming pools,inground spas and portable spas(Mandatory). The energy requirements for residential pools and inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSI/APSP-15.The energy requirements for portable spas shall be in accordance with ANSI/APSP-14. 0 R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on-off switch that is mounted outside the heater to allow shutting off the heater without adjusting the thermostat setting. R403.9.1.1 Gas and oil-fired pool and spa heaters. All gas-and oil-fired pool and space heaters shall have a minimum thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013 when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights. R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. O R403.9.2 Time switches. Time switches or other control method that can automatically turn off and on heaters and pumps according to a preset schedule shall be installed on all heaters and pumps.Heaters,pumps and motors that have built in timers shall be deemed in compliance with this equipment. Exceptions: 1. Where public health standards require 24-hour pump operations. 2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation. O R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor-retardant cover on or .at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Outdoor.pools deriving over 70 percent of the energy for heating from site-recovered energy,such as a heat pump or solar energy source computed over an operating season. ❑ RR404.1 Lighting equipment(Mandatory). A minimum of 75 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps. Exception: Low-voltage lighting shall not be required to utilize high-efficacy lamps. R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights ❑ R405.2 Performance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R-6. O R405.2.1 Performance ONLY. Ceilings shall have minimum insulation of R-19.Where single assemby of the exposed deck and beam type or . concrete deck roofs do not have sufficent space,R-10 is allowed. 1 1/9/201 7 1 0:58 AM EnergyGaugeO USA-FlaRes2014 -Section R405.4.1 Com Page 3 of 3 FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Cali 1828 Elev C Builder Name: DRH Express Homes Street: Permit Office: City,State,Zip: Zephyrhills, FL, Permit Number: Owner: Jurisdiction: Design Location: FL,Tampa COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains.a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/door jambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls ' Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations,and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated,and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical.or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have _F_ gasketed doors 11/9/2017 10:59 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 FLORIDA ENERGY EFFICIENCY CODE FOR.BUILDING CONSTRUCTION Envelope Leakage Test Report Prescriptive and Performance Method Project Name: Cali 1828 Elev C Builder Name: DRH Express Homes Street: Permit Office: City,State,Zip: Zephyrhills, FL, Permit Number: Design Location: FL,Tampa Jurisdiction: Cond.Floor Area:: 1828 sq.ft. Condi Volume: 15849 cu ft. Envelope Leakage Test Results Leakage Characteristics i Regression Data: C: n: R: CFM(50): Single or Multi Point Test Data HOUSE PRESSURE FLOW: ELA: i 1 Pa cfm EgLA: 2 Pa cfm ACH: 3 Pa cfm ACH(50): 4 Pa cfm 5 Pa cfm SLA: 6 Pa cfm I R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2,3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures;. 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3.Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. I hereby certify that the above envelope leakage Where required by the code official, t'VIJES�q performance results demonstrate compliance testing shall be conducted by an with Florida Energy Code requirements in approved third party..A written ` 'f%: accordance with Section.R402.4.1.2. report of the results of the test shall be signed by the third party �_ ...... t7 - conducting the test and provided to � SIGNATURE: the code official. PRINTED NAME: oij y BUILDING OFFICIAL: DATE: DATE: 11/9/2017 10:59 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 I . I FORM R405-2014 Duct Leakage Test Report Performance Method FLORIDA ENERGY EFFICIENCY CODE -FOR BUILDING CONSTRUCTION 'Form R405 Duct Leakage Test Report Performance Method Project Name: Call 1828 Elev C Builder Name: DRH Express Homes Street: Permit Office: City,State,Zip: Zephyrhills,FL, Permit Number: Design Location: FL,Tampa Jurisdiction: Duct Test Time: Post Construction Duct Leakage Test Results CFM25 Duct Leakage Test Values Line System Outside Duct Leakage I System 1 cfm25(Out) 2 System 2 cfm25(Out) 3 System 3 cfm25(Out) 4 System 4 cfm25(Out) 5 Total House Sum lines-1-4 Duct System Leakage Divide by (Total Conditioned Floor Area) (Qn,Out) i certify the tested duct leakage to outside,On, is Duct tightness.ss shall be verified by &0_-CJaKE Sp not greater than the proposed duct leakage On testing to Section 803 of the RESNET 0 0 specified on Form R405-2014. Standards by an energy.rater certified in accordance with Section 553.99, Florida Statutes. SIGNATURE: PRINTED NAME: DATE: BUILDING OFFICIAL: DATE: 11/9/2017 10:59 AM EnergyGaugeg USA-FlaRes2014 Section R405.4.1 Compliant S Page 1 of 1 I 6 ' Manual S Compliance Report Job: - 1- wrightsoft® Date: Oct 10,2014 Entire House By: Progressive Air Systems, Inc 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 • • • For: DR Horton/Express Lot 21 Blk 6 Silverado Ranch, Zephyrhills, FL i Design Conditions Outdoor design DB: 91.2°F Sensible gain: 20798 Btuh Entering coil DB: 75.4°F �. Outdoor design WB: 77.1 OF Latent gain: 2966 Btuh Entering coil WB: 62.7°F Indoor design DB: 75.0°F Total gain: 2V64 Btuh Indoor RH: 50% Estimated airflow: 1000 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: SplitASHP Manufacturer: Carrier Model: CH14NB030****A+FB4CNP030 Actual airflow: 1000 cfm Sensible capacity: 23270 Btuh 112%of load Latent capacity: 3914 Btuh 132%of load Total capacity: 27184 Btuh 1140%of load SHR: 86% I Design Conditions Outdoor design DB: 40.0°F Heat loss: 21100 Btuh Entering coil DB: 69.8°F Indoor design DB: 70.0°F i Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP . Manufacturer: Carrier Model: CH14NB030****A+FB4CNP030 i Actual airflow: 1000 cfm - Output capacity: 25604 Btuh 121%of load Capacity balance: 32 OF Supplemental heat required: 0 Btuh Economic balance: -99 OF _ I Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 1000 cfm Output capacity:. 6.6 kW 107%of load Temp. rise: 20 OF Meets are all requirements of ACCA Manual S. .� wri htSOfts _ 2017-Nov-09 10:59:54 At= "t' 9 Right-Suite®Universal 2017 17.0.21 RSU25554 Page 1 ...on\Wrightsoft Files\Express homes\Cali 4EBB.rup Calc=MJB House faces:NE i • Job: wrightso'ft, Load Short Form Date: Oct 10,2014 Entire House By: - Progressive Air Systems, Inc 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 •j&C • • For: DR Horton/Express Lot 21 Blk 6 Silverado Ranch, Zephyrhills, FL Pesig m Info rthatio Htg Clg Infiltration Outside db(OF) 40 91 Method Simplified Inside db(OF) 70 75 Construction quality Semi-tight Design TD (OF) 30 16 Fireplaces 0 Daily range - L Inside humidity (%) 50 50 Moisture difference(gr/lb) 26 54 HEATING EQUIPMENT COOLING EQUIPMENT Make Carrier Make Carrier Trade CARRIER Trade CARRIER Model CH14NB030****A Cond CH14NB03Q****A AHRI ref Coil FB4CNP030 AHRI ref Efficiency 8 HSPF Efficiency 11.5 EER, 14 SEER Heating input Sensible cooling 22500 Btuh j Heating output 29600 Btuh @ 470F Latent cooling 7500 Btuh Temperature rise 27 OF Total cooling 30000 Btuh Actual air flow 1000 cfm Actual air flow 1000 cfm Air flow factor 0.047 cfm/Btuh Air flow factor 0.048 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.88 Capacity balance point=32 OF Backup: Input=7 kW, Output=22477 Btuh, 100 AFUE ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) M bed 194 3196 2983 151 143 living room 270 2891 3511 137 169 kitchen/dining 349 4292 4955 203 238 bed3 155 1420 1524 67 73 bath2 55 604 281 29 14 bed2 168 341.1 2467 162 119 we 21 24 36 1 2 M bath 114 1276 909 60 44 M wic 66 77- 113 4 5 laundry 39 45 674 2 32 bed4/den opt 169 1866 1736 88 83 A/C closet 19 181 115 9 6 foyer 200 1817 1495 86 72 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrights 2017-Nov-09 10:59:54 oft° Right-Suite®Universal 2017 17.0.21 RSU25554 Page 1 ACCK ..on\Wrightsoft Files\Express homes\Cali 4EBB.rup Calc=MJ8 House faces:NE i Entire House d 1820 21100 20798 1000 1000 Other equip loads 0 0 Equip. @ 1.00 RSM 20798 Latent cooling 2966 TOTALS 1820 21100 23764 1000 1000 I I Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Wrl htsoft 2017-Nov-0910:59:54 ^� 9 Right-Suited Universal 2017 17.0.21 RSU25554/4CCA ...on\Wrightsoft Files\Express homes\Cali 4EBB.rup Calc=MJ8 House faces:NE Page 2 r Project Summary Job: -t - wrightsoft° Date: Oct 10,2014 Entire House By: Progressive Air Systems, Inc 5907 Dasher Ct,Port Richey, FL 34668 Phone:727-847-38.99 Fax:727-815-3399 License:CAC033669 • • • For: DR Horton/Express Lot 21 Blk 6 Silverado Ranch, Zephyrhills, FL Notes: Weather: Tampa Intl AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 40 OF Outside db 91 OF Inside db 70 OF Inside db 75 OF Design TD 30 OF Design TD 16 OF Daily range L Relative humidity 50 % Moisture difference 54 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 17539 Btuh Structure -16200 Btuh Ducts 3561 Btuh Ducts 4598 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 21100 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 20798 Btuh Method Simplified Construction quality Semi-tight Latent Cooling Equipment Load Sizing Fireplaces 0 Structure 2360 Btuh Ducts 606 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling (none) Area(ft2) 1820 1820 Equipment latent load 2966 Btuh Volume(ft3) 16012 16012 _ Air changes/hour 0.26 0.14 Equipment total load 23764 Btuh Equiv.AVF(cfm) 69 37 Req. total capacity at 0.75 SHR 2.3 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER Trade CARRIER Model CH14NB030****A Cond CH14NB030'***A AHRI ref Coil FB4CNP030 AHRI ref Efficiency 8 HSPF Efficiency 11.5 EER, 14 SEER Heating input Sensible cooling 22500 Btuh Heating output 29600 Btuh @ 470F Latent cooling 7500 Btuh Temperature rise 27 OF Total cooling 30000, Btuh Actual air flow 1000 cfm Actual air flow 1000 cfm Air flow factor 0.047 cfm/Btuh Air flow factor 0.048 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.88 Capacity balance point=32.OF Backup: Input=7 kW, Output=22477 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -�- wrightsofV Right-Suite®Universal 2017 17.0.21 ASU25554 2017-Nov-09 10:59:54 ACCK Page 1 ...on\Wrightsoft Files\Express homes\Cali 4EBB.rup Calc=MJ8 House faces:NE FORM R405-2014 RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST Florida Department of Business and Professional Regulation Simulated Performance Alternative (Performance)-Method Applications for compliance with the 2014 Florida Building Code, Energy Conservation via the residential Simulated Performance method shall include ❑ This checklist ❑ A Form R405 report that documents that the Proposed Design complies with Section R405.3 of the Florida Energy Code. This form shall include a summary page indicating home address, a-ratio and the pass or fail status along with summary areas and types of components, whether the home was simulated as a worst-case orientation, name and version of the compliance software tool, name of individual completing the compliance report(I page)and an input summary checklist that can be used for field verification (usually 4 pages/may be greater). ❑ Energy Performance Level(EPL) Display Card(one page) ❑ Mandatory Requirements(three pages) Required prior to CO for the Performance Method: ❑ Air Barrier and Insulation Inspection Component Criteria checklist(Table R402.4.1.1 - one page) ❑ A completed Envelope Leakage Test Report(usually one page) ❑ If Form R405 duct leakage type indicates anything other than "default leakage", then a completed Form R405 Duct Leakage Test Report(usually one page) EnergyGauge@-USRCZB v5.1 11/9/2017 10:13:30 AM Page 1 of 1 CITY OF / / / / BUILDING ZEPHYRHILLS DEPARTMENT OF ADDITION OR CORRECTION D • NOT REMOVE ADDRESS DATE REKNIT� THIS JOB HAS NOT BEEN COMPLETED. The following additions or corrections shall be made before the job will be accepted. SS�Th- o-, v-tt It is unlawful for any Carpenter,Contractor,Builder,or other persons,to AFTER CORRECTIONS ARE MADE L cover or cause to be covered,any part of the work with flooring,lath,earth 780-0020 FOR E- S ECor other material,until the proper inspector has had ample time to approve the installation. OFFICE HOURS 7:30AM-4:30 PM MON.-FRI. INSPECTOR I 5335 - 8TH STREET (813)780-0020 CERTIFICATE OF OCCUPANCY Address: 6517 WAGON TRAIL ST Owner: DR HORTON INC ZEPHYRHILLS, FL. 12602 TELECOM I Subdiv: SILVERADO TEMPLE TERRAC Parcel: 05-26-21-0080-00600-0210 Work Type: 101-NEW CONSTI Construction Type: NOT APPLICABLE ❑ Sprinklers Use Classification: NOT APPLICABLE Permit Number: 19590 Date: � U/2018 ISSUED BY• —BUILDIIl WATER MUST BE CHANGED OVER WITHIN 10 DAYS OF GARBAGE DEPOSIT MUST BE APPLIED FOR PRIOR TO FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Envelope Leakage Test Report Prescriptive and Performance Method Project Name: SILVERADO Builder Name: D R HORTON Street: 6517 Wagon Trail St Permit Office: City,State,Zip: Zephyrhills,FL 33541 Permit Number: Design Location: 6517 Wagon Trail St(Lot 21) Jurisdiction: Cond.Floor Area: 1828 Cond.Volume: tV 15849 Envelope Leakage Test Results Leakage Characteristics Regression Data: C: n: R: CFM(50): 1492 Single or Multi Point Test Data ELA: 82 HOUSE PRESSURE FLOW: 1 50 Pa 1492 cfm EgLA: 194 ACH: 5.65 2 0 Pa 0 cfm SLA: .04 3 0 Pa 0 cfm 4 0 Pa 0 cfm ACH(50)*: 5.65 *For prescriptive projects,tested leakage must be—7: 5 0 Pa 0 cfm ACH(50). For performance projects, tested leakage must be—the ACH(50)shown on Form R405-2014 6 Pa cfm for this project. R402.4.1.2 Testing.The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zones 1 and 2.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statutes or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration 3.Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. I hereby certify that the above envelope leakage performance results demonstrate compliance with Florida Energy Code requirements in accordance with Section R402.4.1.2. Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7), Florida Statutes 0,1-tKES742F or individuals licensed as set forth in Section 489.105(3)(9,(g),or(i)or an approved third party.A `' _� <O written report of the results of the test shall be signed —1 Digitally signed by Michael by the third party conducting the test and provided to Silberstein the code official. , Date:2018.09.1913:43:29 EDT ,t CN=Michael Silberstein,O=TopBuild Home Services,OU, EMAI LADDRESS=Mich ael.S ilb erstei Signature: n@topbuild.wm,C=US Michael Silberstein BUILDING OFFICIAL: Printed Name: Date: 09/19/2018 DATE: ti I Thank you for allowing TopBuild the opportunity to provide the above services for you.Please feel free to contact me with any questions. 10/25/2017 396267