HomeMy WebLinkAbout18-19590 CITY OF ZEPHYRHILLS
5335-8TH STREET
(813)780-0020 19590
BUILDING PERMIT SINGLE FAMILY RESIDENTIAL
PERMIT INFORMATION - LOCATION INFORMATION
Permit#:19590 Issued: 4/26/2018 Address: 6517 WAGON TRAIL ST
Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL.
Class of Work: 101-NEW CONST/SFR Township: Range:
Proposed Use: NOT APPLICABLE Lot(s): Block: Section:
Sq. Feet: Est. Value: Book: Page:
Cost: 266,079.30 Total Fees: 11,394.69 Subdivision: SILVERADO
Amount Paid: 11,394.69 Date Paid: 4/26/2018 Parcel Number: 05-26-21-0080-00600-0210
CONTRACTOR INFORMATION . OWNER INFORMATION
Name: D R HORTON INC Name: DR HORTON INC
Addr: 12602 TELECOM DR Address: 12602 TELECOM DR
TAMPA, FL. 33637 TEMPLE TERRACE FL 33637-0935
Phone: Lic: Phone: 813-549-1968
Work Desc: CONSTRUCT SINGLE FAMILY HOME 2,362 SQ FT
APPLICATION FEES
BUILDING FEE 1,088.77 ELECTRICAL FEE 222.53 PLUMBING FEE 148.35
MECHANICAL FEE 103.85 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00
PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE-sfr/100% 4,828.00
SCHOOL IMPACT FEE-sfr/1% 48.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32
/ yy/
� l
Q.-:&-5' Inspections Required
FOOTER 2ND ROUGH PLUMB Misc INSULATION CEILING
FOOTER BOND DUCTS INSULATED SEWER MISC.
ROUGH ELECTRIC LINTEL MISC MISC.
1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC.
DUCTS INSTALLED WATER MISC DRIVEWAY
PRE-SLAB SHEATHING MISC. MISC.
CONSTRUCTION POLE FRAME MISC. MISC.
REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES:
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing, consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance
with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
CONTRACTORS SIGNATURE PERMIT OFFI
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
i
D R HORTON INC-6517 Wagon Trail-2,362 sq ft
Column
SO. FEET PRICE
MAIN OR LIVING: 2,362 $ 112.65
OTHER AREA UNDER ROOF: -
OTHER: - $ -
VALUATION $ 266,079.30
FEE SHEET $ 989.00
ADDRESS $ 40.00
DRIVEWAY $ 40.00
BUILDING: $ 1,088.78
ELECTRICAL: $ 222.53
PLUMBING: $ 148.35
MECHANICAL: $ 103.85
SUB-TOTAL $ 1,563.50
TOTAL $ 1,563.50
SEWER: n/a
WATER: n/a
IRRIGATION: $ -
TOTAL: $ -
WATER METER: n/a
IRRIGATION METER $ -
FIRE DEPARTMENT FEES
PLANS TOTAL:
INSPECTION TOTAL:
PERMIT TOTAL
TOTAL: $ -
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
FIRE $ 273.00
5% $ 26.35
TOTAL: $ 553.35
SUB-TOTAL $ 2,116.85
PARK IMPACT FEES $ 769.56
SIF'S: $ 4,828.00
100.0% $ 4,828.00
1.0% $ 48.28
TOTAL: $ 4,876.28
T I F'S: $ 3,632.00
99% $ 3,595.68
1% $ 36.32
TOTAL: $ 11,394.69
INSTR#2O18OG5719 OR BK 9711 PG 2264 Page 1 of 1
04/19/2018 10:54 AM Rcpt:1950010 Rec:10.00 DS:0.00 IT:0.00
Paura S.O'Neil P(1.D.,Pasco County-Clerk&Comptroller
c
Permit No. Parcel lDNo OS 2,IVvbV�OpG�O2��
�--�1 NOTICE OF COMMENCEMENT
fT
State of.--7 1 r l(�Q_. County of V r//1 Q 2
THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and In accordance wrath Cha ter 713.Florida Statutes,
the following information is provided in this Notice of Comme cemept�I '� ,'vim / p
1. Description of Property: Parcel Identification No. �;��� (�[J / j tp C�/
Street Address: G.5 17 L Q1� l f u-, I � /- ZQA l/7��-4/ 33S�'(
2. General Description of Improvement Y t.Q -S l�(Q [e r a Vo rr I
3. Owner Information or Lessee information If the Lessee contracted for the improvement:
T)- R-aac ',
1 u 02 " Q.I�rr,M r lntilpc.� t��t o
Address City r State
Interest in Property: _ .Pee S51M_0
Name of Fee Simple Titleholder.
(If different from Owner listed above)
Address T) n�r t r n 37A0 City
r. State
4. Contractor
ontracto p�1
J�00.1 1 ame re,�elAM r '� lMd�CZ 3J�c� >CL
Address City r State
Contractor's Teelephone No.:
5. Surety N
Name'
Address A' City State
Amount of Bond: $ A Telephone No.:
6. Lender.
Address City Slate
Lender's Telephone No.:
7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by
Section 713.13(1)(a)M,Florida Statutes:
Name n // moo-7-
Address
�:4y_0 't State
Telephone Number of Designated Person: �6.C2-!I 9 �/`7�(
8. In addition to himself,the owner designates ��/�/'7 of_
to receive a copy of the Llenor's Notice as provided in Section 713.13(1)(b),Florida Statutes.
Telephone Number of Person or Entity Designated by Owner.
9. Expiration date of Notice of Commencement(the expiration date may not be before the completion of construction and final payment to the
contractor,but will be one year from the date of recording unless a different dale is specified):
WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE DCP(RATION OF THE NOTICE OF COMMENCEMENT
ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE
RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT.
Under penalty of perjury,1 declare that 1 have read the foregoing notice of commencement and that the facts stated therein are true to the best
of my knowledge and belief.
STATE OF FLORIDA
COUNTY OFPASCO
S gna ure of Owner or Lessee,or Owner's or Lessee's Authorized
Officer ireclor/Partner/Manager
ASs -- - D-.�
Signatory's TIitle1Office /gyp L
The foregoing instrument was acknowledged before me/this� ,yda�y,pof KDCI 1 ,20�y 1�1 QG Ci 1, �I O
ash f Y/r(b I W r/""CCC (type of authodty,e.g.,officer,trustee,attorney in fact)for
11 /qo f n Tn 0 (name of party on b al f who i IInnsttrrument was executed).
Personally Known Lit OR Produced Identification Cl' Notary Signature
Type of Identification Produced Name(Print) 17
NNotary Public State of Florida
Michelle Moyes
My Commtssion GG 057321
F�kes1221/2020
wpdata/bcslnoticecommencement pc053048
PASCO COUNTY
DA DEVELOPMENT SERVICES
Jul-6 C 8731 Citizens Drive Date:8/15/2018
COUNTY FLORIDA'
Orin SlYCES.1/ffikriVt PIACI-S. New Part Richey,FL 34654
727-847-2411
NOT A PERMIT
Receipt#: 17$4985
FEE-DESCRIPTION ACCOUNT CODE UNITS INVOICE# FEE AMOUNT PAID RECEIPT# DATE
Impact Fee Residential Solid 24503100-329010 23.96 13748.50 $23.196 $23.96 1784985 8/15/18 i
Waste Single Family
TOTALS: $23.96 $23.96
Receipt# Paid By Check# CC Auth# Cashier ID Workstation Receipt Date Amt Paid
1784985 Check 791243 556 BCCCP35W 08115/2018 $23.96
Total Payments: $23.96
Pa or Address Phone
d.r horton
Comments:
City of Zephyrhi" .d waste#105
Add 1. 517 wagon trail st.
es
Par
re05 26 21 !!"' 00 0210
While you will b-e—p57rag'your bill with Pasco County Development Services,the full amount of the credit card or e-check fees,NOT shown above,Is collected by
First Billing payment services.
MyReports/reports//PASCOPROD/PASC0/ReceiptPOS_y6.rpt 8/15/2018 Page 1 of 1
i
�. PASCO COUNTY, FLORIDA
Permit No. 425�0
cj, Date Permitted —1
-Builder Name/Owner Name {t) Q tiJr � Control#
County Parcel No, [} 2(0 2 t.0 OBP^b�(flpD-b z t b .SubDiv: �, ( r a
Address/Location Oy+ �t(64s
(
t
Classitication(rype of Use 6 e t
TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: Zt 3�rZ i
Exempt []Yes ❑ No How Determined
Impact Fee Amount Zone No. TAZ:
SCHOOL IMPACT FEE
'. Account (056) Single-Family Detached House Amount $
(057) Mobile Home
?' (056) Other Residential
123) Collection Fee
Exempt n Yes ❑ No How Determined
' PARKS AND RECREATION FEE {
Land Account Land Credit Land Total
i Recreation Account Recreation Credit Recreation Total
Zone TOTAL AMOUNT $ �torJ
i
Exempt ❑ Yes ❑ No How Determined
LIBRARY FEE
Land Account Land Credit Land Total
Facility Account Facility Credit Facility Total
Exempt ❑Yes ❑ Na How Determined Total Amaun
RESOURCE FEE ERU
TOTAL AMOUNT
Prepared By Checked By
v
NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION
PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE
BEEN PAID AND
RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY
r• Acknowledgement below does not imply acceptance of concurrence,but simply receipt of-a copy of this form,placing
the building permit owner on notice of this assessment and the conditions of payment for same.
DATE RECEIVED BY
RECEIPT NO. DATE BY j
4 ,
05-26-21-0080-00600-0210 Pasco County Property Appraiser Page 1 of 1
Data Current as Of: Weekly Archive - Monday, April 16, 2018
Parcel ID 05-26-21-0080-00600-0210 (Card: 001 of 001)
Classification 00 - Vacant Residential
Mailing Address Property Value
DR HORTON INC Ag Land $0
12602 TELECOM DR Land $2,741
TEMPLE TERRACE FL 33637-0935 Building $0
Physical Address Extra Features $0
6517 WAGON TRAIL STREET
ZEPHYRHILLS, FL 33541
Just Value $2,741
Legal Description (First 4 Lines) Assessed (Non-School Amendment 1) $2,741 j
See Plat for this
Subdivision Taxable Value $2,741
SILVERADO RANCH SUBDIVISION
PHASES 6, 8 &9A PB 75 PG 075
BLOCK 6
LOT 21
Jurisdiction
City of Zephyrhills
_ Land Detail (Card: 001 of 001)
Line _Use Description?Zoning Units Type ^Price ;Condition Value
1_ 0100 SFRMPUD 6,000.00 SF I $0.40 1.00 $2,400
2 0100 SFR I MPUDv 1,362.00 SF i` $0.25 1.00 $341
I
Additional Land_ Information _
Acres 0.17 IITax Areal 30SI 7 Code ResideiMA ntial Code', SLVRCPI
Building Information - Use 00 - Unimproved (Card: 001 of 001)
Unimproved Parcel 00 - Unimproved
_ Extra Features (Card: 001 of 001) _
Line _..__. 'DI escription�--1Year Units �Value
No Extra Features
Sales History = See All 6 sales
Previous Owner: DUNE FL LAND I SUB LLC
Month/Yea rjBook/Page ype�T --I�DO—R—Code ConditionAmount _
04/201 Warranty Deed _1 05 Vacant Multi-Parcel Sale
05/2017 19535 / 0546 . Certificate of Title _ 05 _� Vacant Multi-Parcel Sale,
11/2016 19462 / 0384 }Mineral,Rights or Royalty Transfer! 05 Vacant Multi-Parcel Sale
. I
I
http://search.pascopa.com/parcel.aspx?parcel=2126050080006000210 4/19/2018
813-780-0020 City of Zephyrhills Pe`mit Application Fax-813-780-0021
Building Department
Date Received 0?
• ��
Phone Contact for Permitting
Owner's Name . CS;^ -a, r-. Owner Phone Number f s-L/ c�7 fJ
Owners Address Owner Phone Number L
Fee Simple Titleholder Name Sri: Owner Phone Number
Fee Simple Titleholder Aid-dress
JOB ADDRESS n -{� LOT#
.SUBDIVISION �� PARCELiD
(OBTAINED FROM PROPERTY TAX NOTICE) ;
W014K PROPOSED NEW CONSTR ADD/ALT SIGN Q DEMOLISH
INSTALL_ 8 REPAIR
PROPOSED USE Of SFR COMM OTHER
TYPE OF CONSTRUCTION " ��� BLOCK 0 FRAME STEEL .
DESCRIPTION OF WORK �''t />���G ��rill_ e. 6,-r I` )-
BUILDING SIZE SQ FOOTAGE � HEIGHT
'T'e"rrx-r•v-i-r-s-'-Irr-rr -i-t"i-r-rmr�rrrr'r'r �r-r-Q-Ir�r-t-r�--e-r-' -re-s-I-a���-'e"e�t-c-4 a a-e-e-'a���'e-x�
=BUILDING $ VALUATION OF TOTAL CONSTRUCTION
0ELECTRICAL Is AMP SERVICE -PROGRESS ENERGY W.R.E.C.
,
=PLUMBING $ i
u �
MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION
. SUMO
=GAS 0 ROOFING Q SPECIALTY OTHER
FINISHED FLOOR ELEVATIONS ,� . FLOOD ZONE AREA DYES NO
--4-6-4-i-�a-E-i•-ii-C-•i•-S--F-a-M1-C-i--i�4..r.-1'-�-'�-"1-��F-p--&-➢-•G-I-F-�-1-➢-I--l-'tea-v'�6�d�1--u�'-1--1�•6-'v-E-•➢-°v-:-6-a�s�4y$�um;'.sz�l•-4•-$-4'-➢-•d•-•
BUILDER COMPANY r` - -)c) "t `c's''-� f 1
SIGNATURE REGISTERED Y/ N FEE CURREN Y/N
Address %.� �� � '<i�.m r^ 1Grt� License#
ELECTRICIAN �� ��-,/��- COMPANY4�6
SIGNATURE ," REGISTERED FEE CURREEN Y/N
Address ,ate License# ( �• � r. r�
PLUMBER COMPANY
.SIGNATURE REGISTERED Y/ N FEE CURREN ^ sY�/_N,/,r �
Address 7'��iQ�, F.�,�+ 'tl. iaf ` License#
MECHANICAL COMPANY
SIGNATURE f�-' "'� ---REGISTERED Y I N FEE CURAEN Y/N
Address • J'702 License#' CAL-0,�?;5 6 15
OTHER. Y COMPANY t
r
SIGNATURE REGISTERED Y/ N FEE CURRER Y/N
Address License# ---'�
1111liilililiilllilllilltlili111iii11111l111l1i ! lldll1ll18IB11 ➢ 1 ➢ ➢ 1
RESIDENTIAL Attach(2)Plot Plans; (2)sets of Building Plans; (1)set of Energy Forms;R-O-W Permit for new construction,
Minimum ten (10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Siit•Fence installed,
Sanitary Facilities&1 dumpster;Site Work'Permit for subdivisions/large projects
COMMERCIAL Attach (2)complete sets of Building Plans plus a Life Safety Page; (1)set of Energy Forms.R-O-W Permit for new construction.
Minimum ten (10)working days aftevsubmittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet'compliance
SiGN PERMIT Attach (2)sets of.Engineered Plans.
"PROPERTY-SURVEY required for all NEW construction.
•f-8.-6.-1.-8�.4-0-.•b-l--t•-f-1�-1•.•1-I--{_i�sa--1-tS-1-E•.i.-1-.S-d--1'-C.-S.-E-.l-.d-.6-b-,1-1!•--➢-�-i-•9..•A-.➢ •&-4•-6.�•-9e6--0-9�.1�.�..&-➢-E.-A.mll..�.-Im.➢�•�-5-.1i-�..8..5�6..• �
Directions:
Fill out application completely.
Owner�Contractor sign back of application,notarized
If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500)
** Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized.letter from owner authorizing same
OVER THE COUNTER PERMITTING (copy of contract required)
Reroofs if shingles " Sewers Service Upgrades A/C Fences (Plot/Survey/Footage)
Driveways-Nat over Counter if on public roadways..needs ROW
/
` . . .
` NOTICE OF DEED RESTRICTIONS:
TheundersiQnedundenstandstholthkspernitnaybesub^eotto deed" restrictions".
which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any
applicable deed restrictions.
UNLICENSED CONTRACTORS AND CO0TRACTCR REGPONSIB|UTlES� If the owner has hired a contractor or
uontnaotomtounde�ake work, they may bero iredtobe |ioenaadineccordoncew|thetadaand \oca| rogu|etinna. |fthe contractor is not-licensed as required by (aw, both the owner and contractor may be cited fora miadaineanorvio|atinn
under state law. If the owner or intended-contractor are uncertain as to what licensing requirements may app|yfor'the
intended work, they are advised to contact the-Pasco County Building Inspection Division—Licensing GaoUon st727-847-
8009. Furthermooe, if the owner has hired e contractor or contractors. he is advised to have the contractor(s) oign
portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign � th�
contractor, that may be an indication that he is not properly licensed and is not entitled tb permitting privileges.in Pasco
County.
TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned.understands
that Transportation Impact Fees and Recourse Recovery,Fees may apply to the construction of new buildings, change of
use in existing bVUd|nga, or expansion of existing bu||dings, as specified in Pasco County Ordinance number 89-07 and
90'07. as amended. The undersigned a|so unde[standS, that such fees. as may be dUo, will be identified at the time of
permitting. \t \ofurther understood that Transportation innpont Fees and Resource Recovery Feasnnuatbo paid prior to
receiving o "certificate uf occupancy" or final power release. |f the project does not involve a certificate of occupancy or
final power release, thm faao must be paid prior to permit issuance. Furthermore, if Pasco-County Water/Sewer Impact
fees are due,they must be paid prior to permit issuance |naccordance vvith applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of Work is $2.500.b0 or more, |
certify that i, the applicant, have been provided with a copy of the "Florida Construction, Lien Law—Homeowner's
Protection Guide" prepared by the F|ohda Department of Agriculture.and Consumer Affairs. If the applicant is someone`
other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to
deliver itto the^owner' priortocommencement.
CONTRACTOR'S/OWNER'S AFFIDAVIT: | certify that all the information in this application is accurate and that all work
will be done in compliance with all applicable |awo regulating construction, zoning and land development. Application is �
hereby made to,obtain a permit to do work and installation as indicated. | certify that no work or installation has
commenced prior to issuance of permit and that all work will be performed to. meet standards of all laws regulating
conetnuobon. County and City codes,' zoning regulations, and land development regulations. in the jurisdiction. | also
certify that | understand that the regulations ofothe'r government aQenC\ma may a. ppk/to the intended work, and that it is
my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to:
- Department of Environmental P rote ntion-Cypress Beyheads. VVet|ondAreas and Environmentally Sensitive �
Lands,Water/Wastewater Treatment. ^
- Southwest Florida Water Management D\strict-VVaUs. Cypress. Bayhoado, Wetland Areas, Altering
Watercourses. .
- Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. '
- Department of Health & Rehabilitative Servioea/Environmental Health Unit-Wells, Wastewater Treatment,'.
Septic Tanks. `
- US-Environmental Protection Agency-Asbestos abatement.
- Federal Aviation Authnrity+Runvvaye.
| understand that the following restrictions apply to the use offill:
- Use of fill io not allowed io Flood Zone"V"' unless expressly porrnittad`
- |f the fill material is to be used in -Flood Zone ''A''. it is understood that a drainage -plan addressing a
"compensating volume" will be submitted at time of permitting which is prepared by a professional engineer
licensed by the State VfFlorida.
' If the fill no material a\ is to be used in Flood Zone ^ in connection wit a permitted building using stern vvaU
construction, I certify that fill will be used only to fill the area within the stem wall.
- U fill material is to be used in any area, | certify that use of such fill will not adversely affect adjacent
. properties. If us.a of fill is found to adversely affect adjacent properties, the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for (uta |eaa than one /1\
acre which are elevated by fill, an engineered drainage plan iarequired. _
|f | am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in
this affidavit prior to commencing construction.. | understand that a a6para1e permit may be.required for.electrical work,
p|umbing, signs, wells, pools, air conditioning, gao, or other installations not specifically included in the application. &
permit issued shall be consthued to be a license to proceed with-the work and not as authority to violate, cancel, alter, or
set aside any provisions of the technical codes, nor shall iaouanceofa permit prevent the Building Official from th�res��r
requNngaoonen��nof errors-in plans, oonatnuc�onorvio(ad U
onsofanycodeo. Every permit invalid
un|ona,the work authorized by such permit is unnnnnenosd within six months of permit |aauanoe, or if work authorized'by
th8permitiasUapendodor *bondonedfbrapariod'ofa\u (6) monthaafterthe time the Work \ocommenced. An extension
may be requested, in-writing, from the Building Official for a period not to exceed ninety /QO\ d�ya� and will demonstrate
` justifiable cause for the extension, |f work oeaoes-for ninety /8O\ consecutive d8yo.�the 'job 'a considered abandoned.
`
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE ��F COMMENCEMENT MAY RESULT
IN
YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. \F YOU INTEND TOOBTAIN FlY0A0CJIY8G, COY0SOLTWITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.,
FLORIDAJUR
' A `F_ 117— ,
OWNER OR
ouosnn000 and no (or affirmed) Subscribed and sworn to(or by
. Who is/are personally known mmeorhas/have produceda—si '
------- identification. '
'
�Notary Pubfic�
Notary Public
Notary Public `
. ` «
Co=" "o'No. Commission
'
Name of Notary typed,printed or stamped Name of
Notary_ typed,'—_-_ stamped_
State of Florida
F,11% Notary Public
ML
OF iv Expire$12/21/2020
This Instrument Was Prepared
By And Should Be Returned To:
Lee E.Nelson,Esq.
Shutts&Bowen LLP
4301 W.Boy Scout Blvd.,Suite 300
Tampa,Florida 33607
Tax Identification Nos.: 04-26-21-0070-00100-0200;05-26-21-0080-00600-0210;
05-26-21-0080-00600-0250;05-26-21-0080-00600-0260;
05-26-21-0080-00600-0270;05-26-21-0080-00600-0280;
05-26-21-0080-00600-0310;05-26-21-0080-00600-0320
SPECIAL WARRANTY DEED
This Special Warranty Deed(this"Deed"), executed as of the day of
2018, by DUNE FL LAND I SUB LLC, a Delaware limited liability company C Grantor"),
whose mailing address is 2502 N. Rocky Point Drive, Suite 1050, Tampa,Florida 33607,to D.R.
HORTON, INC., a Delaware corporation ("Grantee"), whose mailing address is 12602
Telecom Drive,Tampa,Florida 33637.
WITNESSETH:
That Grantor, for and in consideration of the sum of ten dollars ($10.00) and other good
and valuable consideration to Grantor in hand paid by Grantee, the receipt and sufficiency of
which is hereby acknowledged, has granted, bargained, and sold to Grantee and Grantee's
successors and assigns forever, the real property situate, lying, and being in Pasco County,
Florida,and described in EXHIBIT A attached hereto and made a part hereof(the"Property").
TOGETHER with all of the Grantor's rights, title and interest in and to all licenses,
approvals,tenements,hereditaments, and appurtenances belonging or in any way appertaining to
the Property.
TO HAVE AND TO HOLD the same in fee simple forever.
And Grantor hereby specially covenants with Grantee that Grantor is lawfully seized of
the Property in fee simple, and hereby specially warrants the title to the Property and will defend
the same against the lawful claims of all persons claiming by, through or under Grantor,but not
otherwise, and that the Property is being conveyed to Grantee subject to those permitted
exceptions identified in EXHIBIT B attached hereto and made a part hereof, provided the
foregoing shall not serve to reimpose the same.
[SIGNATURE ON NEXT PAGE]
i
EXHIBIT A .
Legal Description
Lot 20, Block 1, of SILVERADO RANCH SUBDIVISION PHASES 2, 3 &4, according to the
Plat thereof, as recorded in Plat Book 73, Pages 59 through 65, inclusive, of the Public Records
of Pasco County,Florida.
AND
Lots 21,25,26, 27, 28, 31 and 32, Block 6, of SILVERADO RANCH SUBDIVISION PHASES
6, 8 & 9A, according to the Plat thereof, as recorded in Plat Book 75, Pages 75 through 80,
inclusive, of the Public Records of Pasco County,Florida.
EXHIBIT B
Permitted Exceptions
1. Taxes and assessments for the year 2018 and subsequent years,which are not yet due and
payable.
2. Restrictions, dedications, conditions, reservations, easements and other matters shown on
the plat of SILVERADO RANCH SUBDIVISION PHASES 2, 3 & 4, as recorded in Plat Book
73, Pages 59 through 65, inclusive, of the Public Records of Pasco County, Florida (as to Lot 20,
Block 1).
3. Restrictions, dedications, conditions, reservations, easements and other matters shown on
the plat of Silverado Ranch Subdivision Phases 6, 8 & 9A, as recorded in Plat Book 75, Pages 75
through 80, inclusive, of the Public Records of Pasco County, Florida (as to Lots in Phases 6, 8
&9A).
4. Declaration of Covenants, Conditions and Restrictions, including any amendments or
modifications thereto, recorded in Official Records Book 9443,Page 1105, of the Public Records
of Pasco County, Florida.
5. Notice of Establishment of the Silverado Community Development District recorded in
Official Records Book 9135, Page 1403; Ordinance No. 1241-14 recorded in Official Records
Book 9123, Page 3 and re-recorded in Official Records Book 9179, Page 3371 and re-recorded
in Official Records Book 9399, Page 2667, all of the Public Records of Pasco County, Florida.
6. Ordinance No. 1247-15 recorded in Official Records Book 9170, Page 87, amended by
Ordinance No. 1326-17 recorded in Official Records Book 9551, Page 45, both of the Public
Records of Pasco County, Florida.
7. Terms and conditions of the Declaration of Consent to Jurisdiction of the Silverado
Community Development District, Imposition of Special Assessments, and Imposition of Lien of
Record recorded in Official Records Book 9388, Page 227, of the Public Records of Pasco
County,Florida.
8. Terms and conditions of that certain Lien of Record, Disclosure of Public Financing, and
Maintenance of Improvements of the Silverado Community Development District (Series
2016A-1 Bonds) recorded in Official Records Book 9388, Page 241, of the Public Records of
Pasco County,Florida.
9. Terms and conditions of that certain Lien of Record, Disclosure of Public Financing, and
Maintenance of Improvements of the Silverado Community Development District (Series
2016A-2 Bonds) recorded in Official Records Book 9388, Page 246, of the Public Records of
Pasco County,Florida.
10. Terms and conditions of that certain Subdivider's Agreement recorded in Book 9401,
Page 1466. As to Phases 2, 3, &4.
11. Terms and conditions of that certain Subdivider's Agreement recorded in Book 9618,
Page 2844. As to Phases 6, 8 &9A.
12. Declaration of Consent to Jurisdiction of the Silverado Community Development
District, Imposition of Special Assessments, and Imposition of Lien of Record as recorded in
Book 9598,Page 3122,of the Public Records of Pasco County, Florida.
13. Any lien or right to a lien for labor, services or materials provided in connection with the
construction of the improvements referred to in the Notice of Commencement filed December
21,2017 in Book 9652,Page 2419,of the Public Records of Pasco County, Florida, as to Lot 20,
Block 1.
TPADOCS 22002716128053.0168
i
D. R. Horton-6517 Wagon Trail-2,362 sq ft
Column Es
SQ. FEET PRICE
MAIN OR LIVING: 2,362 $ 112.65
OTHER AREA UNDER ROOF: $ 88.00
OTHER: - $ -
VALUATION $ 266,079.30
FEE SHEET $ 989.00
ADDRESS $ 40.00
DRIVEWAY1 $ 40.00
BUILDING: $ 1,088.78
ELECTRICAL: $ 222.53
PLUMBING: $ 148.35
MECHANICAL: $ 103.85
SUB-TOTAL $ 1,563.50
TOTAL $ 1,563.50
SEWER: n/a
WATER: n/a
IRRIGATION: $ -
TOTAL: $ -
WATER METER: n/a
IRRIGATION METER $ -
FIRE DEPARTMENT FEES
PLANS TOTAL: n/a
INSPECTION TOTAL:
PERMIT TOTAL
TOTAL: $ -
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
FIRE $ 273.00
5% $ 26.35
TOTAL: $ 553.35
SUB-TOTAL $ 2,116.85
PARK IMPACT FEES $ 769.56
SIF'S: $ 4,828.00
100.0% $ 4,828.00
1.0% $ 48.28
TOTAL: $ 4,876.28
T I F'S: $ 3,632.00
99% $ 3,595.68
1% $ 36.32
TOTAL: $ 11,394.69
I
/�� IA:afl1Ufl'
City of Zephyrhills
BUILDING PLAN REVIEW COMMENTS
Contractor/Homeowner: i�
Date Received:
Site: 5 (7 i 'L
Permit Type: f I� r Z 3�aZ-S3--Y-t�
i
Approved Who comments:❑ Approved w/the below comments: Denied w/the below comments: ❑
This comment sheet shall be kept with the permit and/or plans.
l
Kalv' Sw�iize —Plans Examiner Date Contractor and/or Homeowner
y (Required when comments are present)
Single Family.Dwelling
- Plan Review.Comments:
: .
1. RKE. shall be a minirnum:of 8"_above.the road.elevation and an engineered site plan.
2. Lots shall be graded"to.comply with R401.3 of the F.B;C:
3. Compaction festrequired.if 24" or more of-fill dirt is.brought.in:at any one place:
4:: -Tie in survey required before pouring concrete..
5. . Driveways-require a R.O:W. use permit: All 4 sides of driveway.thru the sidewalk shall have
expansion material:.
'6.. All setbacks shall be inet.:.
.7. All.property.markers shall be,uricovered and marked.at time of first.inspection:
8:- :All A.D.A.-requirements shall'be met.:
9- No:electric,plumbing,mechanical;,or-framing shall be covered without an inspection.and
approval first. . ..
10.All Garages shall comply with:section R302:6:of the F.B.C;: (Fire Separation)..
11:Appliances.sha. not:be installed in:a location where subject to mechanical damage unless
protected by approved barriers. M303.4 of the F.B.C.
12. Water heaters shall 3 comply with section.P607. of the F.B.C:
13. Foundation supports for.A/C units.shall be raised at-least 3" above finished grade..' M1308.1
l4. Return air in all:bedrooms.,F.B.C. .M1620.4.:
15: Smoke detectors are to be:installed.in accordance with.R313:.1 of the F.B.C. "
16.:All glazing requirements are to be in accordance with R308.4.of the F.B.C.
17. All means,of egress are to:be in accordance with R311:of the RB.G.,
18. `.`Green gypsum..board"shall not'be-used:as.a backer in.showers'or tubs:R702.4:2.F.B.C.
19. Combination-type'AFCI breakers are-required,at all.locations requiring=an.AFCI.type breaker. .
20: Carbon monoxide alarms will-be required in new.construction-that uses fossil-burning heating
or appliances or an attached garage.:.They shall be.installed in accordance with.tlie F.B.C..
2 L'All plumbing;mechanical,.and electrical shall-lie separate from unit,to:unit: This:-includes all
Underground plumbing acid electric.
22. All 2011 N.E:C: Codes-wili.be enforced:
23:Tamper- Resistant Receptacles in accordance i ith 406.11. of the 2011 N:E:C.
.24: In accordance..with.the Land:Development:Code, lots.shall be,sodded before final of least 10
feet-around the structure:
25.A copy of the eneryy cacls shall be with permitat all times
26. Copy of rnal insulation report shall be.provided with.permit-before.riza
F.F.E.-Finished Floor Elevation
F.B:C-Florida Building Code 6t'Edition
R.O.W.-Right of Way
A.D:A.-Americans with Disabilities Act . N.E.C:-National Electric Code (2011). .
PLOT PLAN
DESCRIPTION:,(AS FURNISHED)
LOT 21, BLOCK 6, SILVERADO RANCH SUBDIVISION PHASE 6, 8 & 9A
AS RECORDED IN PLAT BOOK 75, PAGE(S) 75-80, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA.
as..
ON LOT CAL
CULATIONS
LOT = 7,361 SQ. FT.
LIVING AREA = 1,828
GARAGE = 430 SQ. FT.
SO. FT. 60,
ENTRY = 16 SO FT.
LANAI = 88 K. FT.
PATIO = 0 SO. FT.
DRIVEWAY 453 SO. FT. 21
A/C PAD = 12 SQ, FT.
WALKWAY = 28 SQ. FT.
IMPERVIOUS = 39%
= 2855 SQ. FT.
SOD = 4,506 SQ. FT.
OFF LOT CALCULATIONS
RP
RIGHT OF WAY = 376 so. FT.
DRIVE APRON = 51 SQ. FT.
PUBLIC S/W = 251 SO. FT.
SOD = 74 SO. FT.
TOTALS 105.13
AREA = 7.737 SO. FT.
DRIVEWAY = 504 SQ. FT.
SIDEWALK = 279 SO. FT. 0.
SOD = 4,580 SO. FT. 'Z
�''(o
F" PROPOSED INLET
Curve Toble 00. NOT FIELD LOCATED
Curve#I Length I Rc '9 . .......
d I I I Chord 88cring Ch.rd
C1 I 12.6r 1 50.00'
F--1-8-r
7 F2 55.1
tK
Op
)0* 14-30`55* F,3,1'43'07'E 12,13'
)0' 40*48'42* S46*52-OD-E 38.35'
0 00.
106.1
ry rczn,. 0)
o II >i co
'0 AD (IV
105.9 41" o. /' A-
m (j
.30'
%'J6-, c"f-
- GRAPHIC SCALE /V� 0, /
0 115 30
LO
PREPARED FOR: 04f
A-HORTONIhO n_
*
�RF
BUILDING SETBACKS FLOOD ZONE'X
FRONT- 20' FLOOD ZONE "AE"
REAR: O� (BFE 103.4)
S DE: 15'
7.5'
SIDE STREET: 20'
LEGEND:
NOTES: BUILDING SETBACK LINE Pf POINT OF INTERSECTION
1. ELEVATIONS SHOWN ARE PER LOT GRADING CENTERUNE PC POINT OF CURVATURE
RIGHT OF WAY LINE RP RADIUS POINT
PLANS PROVIDED BY THE CLIENT. PT POINT OF TANGENCY
2. ELEVATIONS ARE BASED ON NAVD 1988 PROPOSED ELEVATION PRC POINT OF REVERSE CURVATURE
DATUM. PCC POINT OF COMPOUND CURVATURE
TYP PROPOSED DRAINAGE FLOW GS CONTYPICALCRETE SLAB
THIS PLOT PLAN IS INTENDED FOR PERMITTING PURPOSES (P) PER PLAT
ONLY. THIS IS NOT INTENDED FOR THE CONSTRUCTION OF CONCRETE CALCULATED
THE PROPOSED HOUSE, REFER TO HOUSE PLAN AND A/C AIR CONDITIONER 'C"P, PLAT BOOK
OPTION LIST FOR CONSTRUCTION. ALL BUILDING SET BACK- S/W SIDE)VALK PGS PAGES
SQ.FT. SQUARE FEET
LINES SHOWN HEREON IS PER DATA FURNISHED BY CLIENT F.E.M.A, FEDERAL EMERGENCY MANAGEMENT AGENCY
AND IS FOR INFORMATIONAL PURPOSES ONLY. F.I.R.M. FLOOD INSURANCE RATE MAP
NAVD NORTH AMERICAN VERTICAL DATUM
THIS IS NOT A SURVEY NGVD NATIONAL GEODETIC VERTICAL DATUM
D&UE DRAINAGE&UTILITY EASEMENT
THIS IS A PLOT PLAN 0 PDE PRIVATE DRAINAGE EASEMENT
!F,LOOD,NOTE, , ONLY UE UTILITY EASEMENT(PUBLIC)
,VE IAMIN,D THE F.I.R.M. MAP NO. 12101CO2816F, SURVEYOR NOTES:
DATED SEPTEMBER 26, 2014.AND FOUND THE SUBJECT PROPERTY 1. THE SURVEYOR HAS NOT ABSTRACTED THE
APPEARS TO UE IN ZONE"X'. AREAS DETERMINED TO BE OUTSIDE THE LAND SHOWN HEREON FOR-EASEMENTS, RIGHT
0.2%ANNUAL CHANCE FLOODPLAIN AND ZONE-AE-, BASE FLOOD OF WAY, RESTRICTIONS OF RECORD WHICH
ELEVATION 103.4. THE SURVEYOR MAKES NO GUARANTEES AS TO THE MAY AFFECT THE TITLE OR USE OF THE LAND. I
ABOVE INFORMATION.PLEASE CONTACT THE LOCAL F.E.M.A. AGENT FOR
VERIFICATION. 2. NO UNDERGROUND IMPROVEMENTS HAVE BEEN !I
BEARING BASIS: LOCATED EXCEPT AS SHOWN.
BEARINGS SHOWN HEREON ARE BASED ON THE CENTERLINE OF WAGON 3. NOT VALID WITHOUT THE AUTHENTIC
TRAIL STREET BEING N53*35'22"W,PER PLAT. ELECTRONIC SIGNATURE-AND THE AUTHENTIC
(FIELD DATE:) REVISED: F ELECTRONIC SEAL OF A FLORIDA LICENSED
SURVEYOR AND MAPPER.
SCALE: 30 FEET ZS U F:;,: \'/F= )r Digitally ignedbyjamesw
1;Bol—
xt 0. -
APPROVED BY: jB 8c MAPPING INC- f, '.�. 11 9-A—imn So mes eying&Mapping,
I Af J, e.
CERTIFICATION OF AUTHORIZATION NUMBER UB#6393 th-
171013 LOT 21, BLK 6 3191 MAGUIRE BOULEVARD, SUITE 200
JOB NO. ema'Fl-jbqfman@wmcorporatexo FOR
ORLANDO. FLORIDA 32803 oat
�-us THE
DRAWN BY-, DSB (467) 426-7979 W�_Z� Dat.2017.11.16 09-30r.00_05_
a PLOT PLAN 11/10/17 KJW WWW.AMERICANSURVEYINGANDMAPPING.COM JAMES W. BOLEMAN PSM# 6485 DATE I
FORM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Cali 1828 Elev C SiBuilder Name: DRH Express Homes / c
Street: 61� 00L rtq� J Permit Office: f a
City,State,Zip: Zephyrhills,FL,�-1. -1) Permit Number: ��p
Owner: \ Jurisdiction: G f t&0a
Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(1710.2 sgft.) Insulation Area
2:-Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1404.00 ft2
b.Frame-Wood,Adjacent R=11.0 306.22 ft2
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 4 d.N/A R= ft2
10.Ceiling Types (1828.0 sgft.) Insulation Area
5. Is this a worst case? No a.Under Attic(Vented) R=30.0 1828.00 ft2
6. Conditioned floor area above grade(ft2) 1828 b.N/A R= ft2
Conditioned floor area below grade(ft2) 0 11. Duct
c. R= ft2
s R ft2
7. Windows(166.5 sgft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 356
a. U-Factor: Dbl, U=0.34 126.50 ft2
SHGC: SHGC=0.31
b. U-Factor: Dbl,U=0.55 40.00 ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.34 a.Central Unit 28.6 SEER:14.00
c. U-Factor: N/A ft2
SHGC: 13. Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a.Electric Heat Pump 28.6 HSPF:8.20
SHGC:
Area Weighted Average Overhang Depth: 2.722 ft.
Area Weighted Average SHGC: 0.317 14.Hot water systems
8. Floor Types (1828.0 sg a.Electric Cap:50 gallonsft.) Insulation Area EF:0.950
a.Slab-On-Grade Edge Insulation R=0.0 1828.00 ft2 b. Conservation features
b.N/A R= ft2 None
c.NIA R= ft2 15.Credits Pstat
Total Proposed Modified Loads: 61.51 PASS
SS
Glass/Floor Area: 0.091 Total Baseline Loads: 61.25
I hereby certify that the plans and specifications covered by Review of the plans and 0 �famE S �Tfi
this calculation are in compliance with the Florida Energy specifications covered by this
Code. calculation indicates compliance
with the Florida Energy Code.
PREPARED BY: cities• Before construction is completed
DATE: this building will be inspected for ...
compliance with Section 553.908
I hereby certify that this building, as designed,is in compliance Florida Statutes. �S
with.the Florida Energy Code. / GODi tg�
OWNER/AGENTx%� BUILDING FFICIAL: L
DATE: DATE: f
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.2.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
test report in accordance with R402.4.1.2.
- Compliance With a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with Section 803 of RESNET Standards, is not greater than 0.060 Qn for whole house.
1 1/9/201 7 1 0:58 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4
I
FORM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of--Business and Professional Regulation - Residential-Performance Method'
Project Name: Cali 1828 Elev C Builder Name: DRH Express Homes
Street: 0- a- ,/! �[=1,J J 1 Permit Office:
City,State,Zip: Zephyrhills, FL, c i 1 4 Permit Number:
Owner: - I r ( � Jurisdiction:
Design Location: FL,Tampa IZ\11 County:: Pasco(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(1710.2 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insui,Exterior R=4.1 1404.00 ft2
b. Frame-Wood,Adjacent R=11.0 306.22 ft2
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number.of Bedrooms 4 d.N/A R= ft2
10.Ceiling Types (1828.0 sqft,) Insulation Area
5. Is this a worst case? No a.Under Attic(Vented) R=30.0 1828.00 ft2
6. Conditioned floor area above grade(ft2) 1828 b.N/A- R= ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ft2
11. Ducts R ft2
7. Windows(166.5 sqft.) Description Area a.Sup:Attic, Ret:Main,AH:Main 6 356
a. U-Factor: Dbl,U=0.34 126.50 ft2
SHGC: SHGC=0.31
b. U-Factor: Dbl,U=0.55 40.00 ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.34 a.Central Unit 28.6 SEER:14.00
c. U-Factor: N/A ft2
SHGC: 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a.Electric Heat Pump 28.6 HSPF:8.20
SHGC:
Area Weighted Average Overhang Depth: 2.722 ft.
Area Weighted Average SHGC: 0.317 14. Hot water systems
B. Floor Types (1828.0 sg a.Electric Cap:50 gallons
ft.) Insulation Area EF:0.950
a.Slab-On-Grade Edge Insulation R=0.0 1828.00 ft2 b. Conservation features
b.N/A R= ft2 None
c.N/A R= ft2 15.Credits Pstat
����
Glass/Floor Area: 0.091 Total Proposed Modified Loads: 61.51
Total Baseline Loads: 61.25
I hereby certify that the plans and specifications covered by Review of the plans and T%ES.
this calculation are in compliance with the Florida Energy specifications covered by this , O
Code. calculation indicates compliance ��v,;, %s "4z .
with the Florida Energy Code.
PREPARED BY: 1,1& ,�,,;., Before construction is completed
DATE: n-g-n this buildingwill be inspected for - � - ,Cf
p � 1 a .
compliance with Section 553.908
I hereby-certify that this building, as designed,is in compliance Florida Statutes. - ' S�
with the Florida Energy Code.. 1117WE
OWNER/AGENT,�- 1pl BUILDING OFFICIAL:
DATE: DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.2.2.1. -
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
test report in accordance with R402.4.1.2.
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with Section 803 of RESNET Standards, is not greater than 0.060 Qn for whole house.
11/9/2017 10:58 AM EnergyGauge@ USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4
FORM R405-9014
PROJECT '
Title: Cali 1828 Elev C Bedrooms: 4 Address Type: Lot Information
Building Type: User Conditioned Area: 1828 Lot# 21/6
Owner: Total Stories: 1 Block%SubDivision: Silverado Ranch
#of Units: 1 Worst Case: No PlatBook:
Builder Name: DRH Express Homes Rotate Angle: 45 Street:
Permit Office: Cross Ventilation: County: Pasco
Jurisdiction: Whole House Fan: City,State,Zip: Zephyrhills,
Family Type: Single-family FL,
New/Existing: New(From Plaps)
Comment: Garage R Face NE
CLIMATE
/ IECC Design Temp Int Design Temp Heating Design Daily Temp
Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,Tampa FL_TAMPA_INTERNATI 2 39 91 70 75 645.5 54 Medium
BLOCKS
Number Name Area Volume
1 Blockl 1828 15848.8
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
1 Main 1828 15848.8 Yes 5 4 1 Yes Yes Yes
FLOORS
# Floor Type Space Perimeter R-Value Area Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio Main 198.6 ft 0 1828 ft2 ---- 0 0.25 0.75
ROOF
/ Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
# Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
1 Hip Composition shingles 2044 ft2 0 ft2 Dark 0.92 No 0.9 No 0 26.6
ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Vented 300 1828 ft2 Y N
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Vented) Main 30 Blown 1828 ft2 0.11 Wood
i
1 1/9/201 7 1 0:58 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 4
I
FORM R405=2014
WALLS
Adjacent S# r)Mt To Wall Typepace Cavity Width Height Sheathing Framing Solar Below
1 N=>NE Exterior Concrete Block-Int Insul ' Main 4.0999 19 8 8 164.7 ft2 .0 0.6 0
2 W=>NW Exterior Concrete Block-Int Insul Main 4.0999 43 8 8 8 378.4 ft2 0 0.6 0
3 S=>SW Exterior Concrete Block-Int Insul Main :4.0999 39 8 8 8 343.8 ft2 0 0.6 0
4 E=>SE Exterior Concrete Block-Int Insul Main 4.0999 59 8 8 8 517.1 ft2 0 0.6 0
5 N=>NE Garage Frame-Wood Main 11 20 0 8 8 173.3 ft2 0.23 0.01 0
_6 W=>NW Garage Frame-Wood Main 11 15 4 8 8' 132.9 ft2 0.23 0.01 0
DOORS
# Omt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 N=>NE Insulated Main None .4 3 6 8 20 ft2
2 N=>NE Wood Main None .46 2 8 6 8 17.8 ft2
WINDOWS
Orientation shown is the entered orientation => changed to As Built rotated 45 degrees).
Wall Overhang
# Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening
1 N=>NE 1 Vinyl Low-E Double Yes 0.34 0.31 31.0 ft2 1 ft 0 in 4 ft 1 in Drapes/blinds Exterior 5
2 N=>NE 1 Vinyl Low-E Double Yes 0.34 0.31 2.5 ft2 3 ft 8 in 0 ft 0 in Drapes/blinds Exterior 5
3 W=>NW 2 Vinyl Low-E Double Yes 0.34 0.31 15.5 ft2 1 ft 0 in 0 ft 9 in Drapes/blinds Exterior 5
4 S=>SW 3 Vinyl Low-E Double Yes 0.34 0.31 62.0 ft2 1 ft 0 in 0 ft 9 in Drapes/blinds Exterior 5
5 S=>SW 3 Metal Low-E Double Yes 0.55 0.34 40.0 ft2 8 ft 0 in 0 ft 8 in Drapes/blinds Exterior 5
6 E=>SE 4 Vinyl Low-E Double Yes 0.34 0.31 15.5 ft2 1 ft 0 in 0 ft 9 in Drapes/blinds Exterior 5
GARAGE
# Floor Area Ceiling Area Exposed Wall,Perimeter Avg.Wall Height Exposed Wall Insulation
1 430.0128 ft2 430.0128 ft2 46.6 ft 8.67 ft 0
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000386 1849_ 101.51 190.9 .2892 7.
HEATING SYSTEM
# System Type Subtype Efficiency Capacity Block Ducts
1 Electric Heat Pump None HSPF:8.2 28.6 kBtu/hr 1 sys#1
I
11/9/2017 10:58.AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 4
FORM R405-2014
COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit None SEER:_1, 28.6 kBtu/hr 858 cfm 0.75 1 sys#1
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.95 50 gal 70 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model#• Collector Model# Area Volume FEF
None None ftz
DUCTS
----Supply---- ----Return---- Air CFM 25 CFM25 HVAC#
# Location R-Value Area Location Area 'Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 356 ftz Main 40 ft2 Proposed Qn Main ---cfm '109,7 0b 0.66 0.80 1 1
TEMPERATURES
Programable Thermostat:Y Ceiling Fans:
CoolingJan Feb Mar Apr _ Ma Jun Jul Auge Oct Nov Dec
Heatin Jan f X}Feb Mar Apr f May f Jun f Jul f Auf Sep E Oct Nov Dec
Vent!n Jan [ ]Feb Mar Apr l May [ Jun [ Jul [ Aug [ Se [X]Oct Nov Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11- 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 _ 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
1 1/9/201 7 1 0:58 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 4
FORM R405-2014
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 100
The lower the EnergyPerformance Index,the more efficient the home.
Zephyrhills, FL,
1. New construction or existing New(From Plans) 9. Wall Types Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1404.00 ftz
b.Frame-Wood,Adjacent R=11.0 306.22 ftz
3. Number of units,if multiple family 1 c.N/A R= ftz
4. Number of Bedrooms 4 d.N/A R= ftz
5. Is this a worst case? No 10.Ceiling Types Insulation Area
a.Under Attic(Vented) R=30.0 1828.00 ft2
6. Conditioned floor area(ftz) 1828 b.N/A R= ftz
_ z
7. Windows" Description Area 11 cDucts R R ftz
a. U Factor: Dbl,U=0.34 126.50 ftz a.Sup:Attic,Ret:Main,AH:Main 6 356
SHGC: SHGC=0.31
b. U-Factor: Dbl,U=0.55 40.00 ftz
SHGC: SHGC=0.34 12.Cooling systems kBtu/hr Efficiency
c. U-Factor: N/A ftz a.Central Unit 28.6 SEER:14.00
SHGC:
d. U-Factor: N/A ftz 13.Heating systems kBtu/hr Efficiency
SHGC: a.Electric Heat Pump 28.6 HSPF:8.20
Area Weighted Average Overhang Depth: 2.722 ft.
Area Weighted Average SHGC: 0.317
8. Floor Types Insulation Area - 14.Hot water systems
a.Slab-On-Grade Edge Insulation R=0.0 1828.00 ftz a.Electric Cap:50 gallons
EF:0.95
b.N/A R= ftz
c.N/A R= ftz
b. Conservation features
None
15.Credits Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for BuildinggE ST
Construction through the above energy saving features which will be installed (or exceeded) w0�
in this home before final inspection. Otherwise, a new EPL Display Card will be completed �;v.`,,,,''f�'
e^
based on installed Code compliant features. a
Builder Signature: Date:
Address of New Home: , (' I f City/FL Zip: 7-r
- - J L caD �
Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
11/9/2017 10:58 AM EnergyGauge@ USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1
FORM R405-2014 .
Florida Department of Business and Professional Regulations
Residential Whole Building Performance and Prescriptive Methods
ADDRESS: Permit Number:
Zephyrhills,FL,
MANDATORY REQUIREMENTS See individual code sections for full details.
❑ 401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL)
display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law
(Section 553.9085, Florida Statues]requires the EPL display card to be included as an addendum to each sales contract for both presold and
nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components
installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans
and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix C.
❑ R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of
Sections R402.1 through R402.4.4.
O R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.The
sealing methods between dissimilar materials shall allow for differential expansion and contraction.
• R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in
accordance with the manufacturer's instructions and the criteria listed in Table 402.4.1.1,as applicable to the method of construction.
Where required by the code official,an approved third party shall inspect all components and verify compliance.
• R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air
changes per hour in Climate Zones 1 and 2,and 3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with
a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an
approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code
official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
During testing:
1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or
other infiltration control measures;
2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended
infiltration control measures;
3.Interior doors,if installed at the time of the test,shall be open;
4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed;
5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and
6.Supply and return registers,if installed at the time of the test,shall be fully open.
O R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers and outdoor combustion air.
i
O R402.4.3 Fenestration air leakage.Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm
per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400 or
AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer.
Exception: Site-built windows,skylights and doors.
O R402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage
between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not
more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential.All recessed
luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering.
❑ R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system.
❑ R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls
that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load.
❑ R403.2.2 Sealing(Mandatory)AII ducts,air handlers,and filter boxes and building cavities that form the primary air containment
passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance
with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post-construction
or rough-in testing below.
Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either an energy rater certified in accordance with Section
553.99,Florida Statutes,or as authorized by Florida Statutes,to be"substantially leak free"by either of the following:
1. Post-construction test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area
when tested at a pressure differential of 0.1 inches w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure.All
register boots shall be taped or otherwise sealed during the test.
2. Rough-in test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested
at a pressure differential of 0.1 inches w.g. (25Pa)across the system,including the manufacturer's.air handler enclosure.All registers shall be
taped or otherwise sealed during the test.If the air handler is not installed at the time of the test,total leakage shall be less than or equal to 3 cfm
(85 Umin)per 100 square feet(9.29 m2)of conditioned floor area.
Exceptions:
1. The total leakage test is not required for ducts and air handlers located entirely within.the building envelope.
2. Duct testing.is not mandatory for buildings complying by Section R405 of this code.
1 1/9/201 7 1 0:58 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Com Page 1 of 3
FORM R4C5-2014
MANDATORY REQUIREMENTS - (Continued)
❑ R403.2.3 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums.
❑ R403.3 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C)
or below 55°F(13°C)shall be insulated to a minimum of R-3.,
R403.3.1 Protection of piping insulation.
❑ R403.4.1 Circulating hot water systems(Mandatory). Circulating hot water systems shall be provided with an automatic or readily
accessible manual switch that can turn off the hot-water circulating pump when the system is not in use.
❑ R403.4.3 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have
heat traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a
downward and upward bend of at least 3 1/2 inches(89 mm)in the hot-water distribution line and cold water line located as close as possible
to the storage tank.
❑ R403.4.4 Water heater efficiencies(Mandatory).
0 R403.4.4.1 Storage water heater temperature controls
R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls
capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum
temperature setting range shall be from 100°F to 140°F(38°C to 60°C).
R403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied
to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s)
of combustion types of service water heating systems to be turned off.
0 R403.4.4.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of
Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed.
Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water
heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1.
R403.4.4.2.1 Solar water heating systems. Solar systems for domestic hot water production are rated by the annual solar energy
factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of
Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9306,Test Methods for Solar Collectors,
and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol,Collectors in installed solar water
heating systems should meet the following criteria:
1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and
2. Be installed at an orientation within 45 degrees of true south.
❑ R403.5 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the
Florida Building Code,Residential or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation.
Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating.
❑ R403.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment.
0 R403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the
equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies,
based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and
indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions
described in Section R302.1.This code does not allow designer safety factors,provisions for future expansion or other factors
which affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation
such as standard kitchen and bathroom exhaust systems.
R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the
calculated total load,but not more than 1.15 times greater than the total load calculated according to the procedure selected in
Section 403.6,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the
equipment shall not be less than the calculated latent load.
11/9/2017 10:58 AM EnergyGauge@ USA-FlaRes2014 Section R405.4.1 Cam Page 2 of 3
FORM R405-2014
MANDATORY REQUIREMENTS - (Continued)
0 R403.6.1.1 Cooling equipment capacity.(continued) The published value for AHRI total capacity is a nominal,rating-test value and
shall not be used for equipment sizing.Manufacture's expanded performance data shall be used to select cooling-only equipment.This
selection shall be used to select cooling-only equipment.This selection_shall be based on the outdoor design dry bulb temperature for the
load calculation(or entering water temperature for water-source equiPrnent),the blower cfm provided by the expanded performance data,
the design value for entering wet bulb temperature and the design value for entering dry bulb temperature.
Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load
calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space.
Exceptions:
1. Attached single-and multi-family residential equipment sizing may be selected so that its cooling capacity is less than the
calculated total sensible load but not less than 80 percent of that load.
2. When signed and sealed by a Florida-registered engineer,in attached single-and multi-family units,the capacity of
equipment may be sized in accordance with good design practice.
0 R403.6.1.2 Heating equipment capacity
• R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section
R403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load.
• R403.6.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design
requirements calculated according to the procedure selected in Section R403.6.1.
• R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners
shall not be less than the design load calculated in accordance with Section R403.6.1.
0 R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an
intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to
prevent continuous space cooling or heating within that space by one or more of the following options:
1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas.
2. A variable capacity system sized for optimum performance during base load periods is utilized.
❑ R403.7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections
C403 and C404 of the Commercial Provisions in lieu of Section R403.
❑ R403.8 Snow melt system controls(Mandatory). Snow and ice-melting systems,supplied through energy service to the building,shall
include automatic controls capable of shutting off the system when the pavement temperature is above 55°F,and no precipitation is falling
and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F.
❑ R403.9 Swimming pools,inground spas and portable spas(Mandatory). The energy requirements for residential pools and
inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSI/APSP-15.The energy
requirements for portable spas shall be in accordance with ANSI/APSP-14.
0 R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on-off switch that is mounted
outside the heater to allow shutting off the heater without adjusting the thermostat setting.
R403.9.1.1 Gas and oil-fired pool and spa heaters. All gas-and oil-fired pool and space heaters shall have a minimum
thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013 when tested in accordance with ANSI Z 21.56.
Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights.
R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance
with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is
required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard.
O R403.9.2 Time switches. Time switches or other control method that can automatically turn off and on heaters and pumps according to a
preset schedule shall be installed on all heaters and pumps.Heaters,pumps and motors that have built in timers shall be deemed in
compliance with this equipment.
Exceptions:
1. Where public health standards require 24-hour pump operations.
2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems.
3. Where pumps are powered exclusively from on-site renewable generation.
O R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor-retardant cover on or
.at the water surface or a liquid cover or other means proven to reduce heat loss.
Exception: Outdoor.pools deriving over 70 percent of the energy for heating from site-recovered energy,such as a heat pump or
solar energy source computed over an operating season.
❑ RR404.1 Lighting equipment(Mandatory). A minimum of 75 percent of the lamps in permanently installed lighting fixtures shall be
high-efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps.
Exception: Low-voltage lighting shall not be required to utilize high-efficacy lamps.
R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights
❑ R405.2 Performance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R-6.
O R405.2.1 Performance ONLY. Ceilings shall have minimum insulation of R-19.Where single assemby of the exposed deck and beam type or
. concrete deck roofs do not have sufficent space,R-10 is allowed.
1 1/9/201 7 1 0:58 AM EnergyGaugeO USA-FlaRes2014 -Section R405.4.1 Com Page 3 of 3
FORM R405-2014
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: Cali 1828 Elev C Builder Name: DRH Express Homes
Street: Permit Office:
City,State,Zip: Zephyrhills, FL, Permit Number:
Owner: Jurisdiction:
Design Location: FL,Tampa
COMPONENT CRITERIA CHECK
Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope.
Exterior thermal envelope contains.a continuous barrier.
Breaks or joints in the air barrier shall be sealed.
Air-permeable insulation shall not be used as a sealing material.
Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the
insulation and any gaps in the air barrier shall be sealed.
Access openings,drop down stairs or knee wall doors to unconditioned
attic spaces shall be sealed.
Corners and headers shall be insulated and the junction of the foundation
Walls and sill plate shall be sealed.
The junction of the top plate and the top or exterior walls shall be sealed.
Exterior thermal envelope insulation for framed walls shall be installed in
substantial contact and continuous alignment with the air barrier.
Knee walls shall be sealed.
Windows, skylights and doors The space between window/door jambs and framing and skylights and
framing shall be sealed.
Rim joists Rim joists are insulated and include an air barrier.
Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside
and cantilevered floors) of subfloor decking.
The air barrier shall be installed at any exposed edge of insulation.
Crawl space walls ' Where provided in lieu of floor insulation, insulation shall be permanently
attached to the crawlspace walls.
Exposed earth in unvented crawl spaces shall be covered with a Class I
vapor retarder with overlapping joints taped.
Shafts, penetrations Duct shafts, utility penetrations,and flue shaft openings to exterior or
unconditioned space shall be sealed.
Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled
by insulation that on installation readily conforms to the available cavity
spaces.
Garage separation Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be
air tight, IC rated,and sealed to the drywall.
Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in
exterior walls,or insulation that on installation readily conforms to available
space shall extend behind piping and wiring.
Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air
barrier installed separating them from the showers and tubs.
Electrical/phone box on The air barrier shall be installed behind electrical.or communication boxes or
air sealed boxes shall be installed.
HVAC register boots HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub-floor or drywall.
Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have _F_
gasketed doors
11/9/2017 10:59 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1
FLORIDA ENERGY EFFICIENCY CODE
FOR.BUILDING CONSTRUCTION
Envelope Leakage Test Report
Prescriptive and Performance Method
Project Name: Cali 1828 Elev C Builder Name: DRH Express Homes
Street: Permit Office:
City,State,Zip: Zephyrhills, FL, Permit Number:
Design Location: FL,Tampa Jurisdiction:
Cond.Floor Area:: 1828 sq.ft. Condi Volume: 15849 cu ft.
Envelope Leakage Test Results Leakage Characteristics
i
Regression Data:
C: n: R:
CFM(50):
Single or Multi Point Test Data
HOUSE PRESSURE FLOW: ELA:
i
1 Pa cfm EgLA:
2 Pa cfm ACH:
3 Pa cfm
ACH(50):
4 Pa cfm
5 Pa cfm SLA:
6 Pa cfm
I
R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour
in Climate Zones 1 and 2,3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2
inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the
test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all
penetrations of the building thermal envelope.
During testing:
1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other
infiltration control measures;.
2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration
control measures;
3.Interior doors,if installed at the time of the test,shall be open;
4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed;
5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and
6.Supply and return registers,if installed at the time of the test,shall be fully open.
I hereby certify that the above envelope leakage Where required by the code official, t'VIJES�q
performance results demonstrate compliance testing shall be conducted by an
with Florida Energy Code requirements in approved third party..A written ` 'f%:
accordance with Section.R402.4.1.2. report of the results of the test shall
be signed by the third party �_ ...... t7
- conducting the test and provided to �
SIGNATURE: the code official.
PRINTED NAME: oij y
BUILDING OFFICIAL:
DATE: DATE:
11/9/2017 10:59 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1
I .
I
FORM R405-2014 Duct Leakage Test Report Performance Method
FLORIDA ENERGY EFFICIENCY CODE
-FOR BUILDING CONSTRUCTION
'Form R405 Duct Leakage Test Report
Performance Method
Project Name: Call 1828 Elev C Builder Name: DRH Express Homes
Street: Permit Office:
City,State,Zip: Zephyrhills,FL, Permit Number:
Design Location: FL,Tampa Jurisdiction:
Duct Test Time: Post Construction
Duct Leakage Test Results
CFM25 Duct Leakage Test Values
Line System Outside Duct Leakage
I System 1 cfm25(Out)
2 System 2 cfm25(Out)
3 System 3 cfm25(Out)
4 System 4 cfm25(Out)
5 Total House Sum lines-1-4
Duct System
Leakage Divide by
(Total Conditioned Floor Area)
(Qn,Out)
i certify the tested duct leakage to outside,On, is Duct tightness.ss shall be verified by &0_-CJaKE Sp
not greater than the proposed duct leakage On testing to Section 803 of the RESNET 0 0
specified on Form R405-2014.
Standards by an energy.rater certified in
accordance with Section 553.99,
Florida Statutes.
SIGNATURE:
PRINTED NAME:
DATE: BUILDING OFFICIAL:
DATE:
11/9/2017 10:59 AM EnergyGaugeg USA-FlaRes2014 Section R405.4.1 Compliant S Page 1 of 1
I
6 '
Manual S Compliance Report Job:
- 1- wrightsoft® Date: Oct 10,2014
Entire House By:
Progressive Air Systems, Inc
5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669
• • •
For: DR Horton/Express
Lot 21 Blk 6 Silverado Ranch, Zephyrhills, FL
i
Design Conditions
Outdoor design DB: 91.2°F Sensible gain: 20798 Btuh Entering coil DB: 75.4°F �.
Outdoor design WB: 77.1 OF Latent gain: 2966 Btuh Entering coil WB: 62.7°F
Indoor design DB: 75.0°F Total gain: 2V64 Btuh
Indoor RH: 50% Estimated airflow: 1000 cfm
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: SplitASHP
Manufacturer: Carrier Model: CH14NB030****A+FB4CNP030
Actual airflow: 1000 cfm
Sensible capacity: 23270 Btuh 112%of load
Latent capacity: 3914 Btuh 132%of load
Total capacity: 27184 Btuh 1140%of load SHR: 86%
I
Design Conditions
Outdoor design DB: 40.0°F Heat loss: 21100 Btuh Entering coil DB: 69.8°F
Indoor design DB: 70.0°F
i
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: Split ASHP .
Manufacturer: Carrier Model: CH14NB030****A+FB4CNP030 i
Actual airflow: 1000 cfm -
Output capacity: 25604 Btuh 121%of load Capacity balance: 32 OF
Supplemental heat required: 0 Btuh Economic balance: -99 OF
_ I
Backup equipment type: Elec strip
Manufacturer: Model:
Actual airflow: 1000 cfm
Output capacity:. 6.6 kW 107%of load Temp. rise: 20 OF
Meets are all requirements of ACCA Manual S.
.� wri htSOfts _ 2017-Nov-09 10:59:54
At= "t' 9 Right-Suite®Universal 2017 17.0.21 RSU25554 Page 1
...on\Wrightsoft Files\Express homes\Cali 4EBB.rup Calc=MJB House faces:NE
i
• Job:
wrightso'ft, Load Short Form Date: Oct 10,2014
Entire House By: -
Progressive Air Systems, Inc
5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669
•j&C • •
For: DR Horton/Express
Lot 21 Blk 6 Silverado Ranch, Zephyrhills, FL
Pesig m Info rthatio
Htg Clg Infiltration
Outside db(OF) 40 91 Method Simplified
Inside db(OF) 70 75 Construction quality Semi-tight
Design TD (OF) 30 16 Fireplaces 0
Daily range - L
Inside humidity (%) 50 50
Moisture difference(gr/lb) 26 54
HEATING EQUIPMENT COOLING EQUIPMENT
Make Carrier Make Carrier
Trade CARRIER Trade CARRIER
Model CH14NB030****A Cond CH14NB03Q****A
AHRI ref Coil FB4CNP030
AHRI ref
Efficiency 8 HSPF Efficiency 11.5 EER, 14 SEER
Heating input Sensible cooling 22500 Btuh j
Heating output 29600 Btuh @ 470F Latent cooling 7500 Btuh
Temperature rise 27 OF Total cooling 30000 Btuh
Actual air flow 1000 cfm Actual air flow 1000 cfm
Air flow factor 0.047 cfm/Btuh Air flow factor 0.048 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.88
Capacity balance point=32 OF
Backup:
Input=7 kW, Output=22477 Btuh, 100 AFUE
ROOM NAME Area Htg load Clg load Htg AVF Clg AVF
(ft2) (Btuh) (Btuh) (cfm) (cfm)
M bed 194 3196 2983 151 143
living room 270 2891 3511 137 169
kitchen/dining 349 4292 4955 203 238
bed3 155 1420 1524 67 73
bath2 55 604 281 29 14
bed2 168 341.1 2467 162 119
we 21 24 36 1 2
M bath 114 1276 909 60 44
M wic 66 77- 113 4 5
laundry 39 45 674 2 32
bed4/den opt 169 1866 1736 88 83
A/C closet 19 181 115 9 6
foyer 200 1817 1495 86 72
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wrights 2017-Nov-09 10:59:54
oft° Right-Suite®Universal 2017 17.0.21 RSU25554 Page 1
ACCK ..on\Wrightsoft Files\Express homes\Cali 4EBB.rup Calc=MJ8 House faces:NE
i
Entire House d 1820 21100 20798 1000 1000
Other equip loads 0 0
Equip. @ 1.00 RSM 20798
Latent cooling 2966
TOTALS 1820 21100 23764 1000 1000
I
I
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
Wrl htsoft 2017-Nov-0910:59:54
^� 9 Right-Suited Universal 2017 17.0.21 RSU25554/4CCA ...on\Wrightsoft Files\Express homes\Cali 4EBB.rup Calc=MJ8 House faces:NE Page 2
r
Project Summary Job:
-t - wrightsoft° Date: Oct 10,2014
Entire House By:
Progressive Air Systems, Inc
5907 Dasher Ct,Port Richey, FL 34668 Phone:727-847-38.99 Fax:727-815-3399 License:CAC033669
• • •
For: DR Horton/Express
Lot 21 Blk 6 Silverado Ranch, Zephyrhills, FL
Notes:
Weather: Tampa Intl AP, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 40 OF Outside db 91 OF
Inside db 70 OF Inside db 75 OF
Design TD 30 OF Design TD 16 OF
Daily range L
Relative humidity 50 %
Moisture difference 54 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 17539 Btuh Structure -16200 Btuh
Ducts 3561 Btuh Ducts 4598 Btuh
Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh
(none) (none)
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 21100 Btuh Use manufacturer's data y
Rate/swing multiplier 1.00
Infiltration Equipment sensible load 20798 Btuh
Method Simplified
Construction quality Semi-tight Latent Cooling Equipment Load Sizing
Fireplaces 0 Structure 2360 Btuh
Ducts 606 Btuh
Central vent (0 cfm) 0 Btuh
Heating Cooling (none)
Area(ft2) 1820 1820 Equipment latent load 2966 Btuh
Volume(ft3) 16012 16012 _
Air changes/hour 0.26 0.14 Equipment total load 23764 Btuh
Equiv.AVF(cfm) 69 37 Req. total capacity at 0.75 SHR 2.3 ton
Heating Equipment Summary Cooling Equipment Summary
Make Carrier Make Carrier
Trade CARRIER Trade CARRIER
Model CH14NB030****A Cond CH14NB030'***A
AHRI ref Coil FB4CNP030
AHRI ref
Efficiency 8 HSPF Efficiency 11.5 EER, 14 SEER
Heating input Sensible cooling 22500 Btuh
Heating output 29600 Btuh @ 470F Latent cooling 7500 Btuh
Temperature rise 27 OF Total cooling 30000, Btuh
Actual air flow 1000 cfm Actual air flow 1000 cfm
Air flow factor 0.047 cfm/Btuh Air flow factor 0.048 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.88
Capacity balance point=32.OF
Backup:
Input=7 kW, Output=22477 Btuh, 100 AFUE
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
-�- wrightsofV Right-Suite®Universal 2017 17.0.21 ASU25554 2017-Nov-09 10:59:54
ACCK
Page 1
...on\Wrightsoft Files\Express homes\Cali 4EBB.rup Calc=MJ8 House faces:NE
FORM R405-2014
RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST
Florida Department of Business and Professional Regulation
Simulated Performance Alternative (Performance)-Method
Applications for compliance with the 2014 Florida Building Code, Energy Conservation via the
residential Simulated Performance method shall include
❑ This checklist
❑ A Form R405 report that documents that the Proposed Design complies with Section
R405.3 of the Florida Energy Code. This form shall include a summary page
indicating home address, a-ratio and the pass or fail status along with summary
areas and types of components, whether the home was simulated as a worst-case
orientation, name and version of the compliance software tool, name of individual
completing the compliance report(I page)and an input summary checklist that can
be used for field verification (usually 4 pages/may be greater).
❑ Energy Performance Level(EPL) Display Card(one page)
❑ Mandatory Requirements(three pages)
Required prior to CO for the Performance Method:
❑ Air Barrier and Insulation Inspection Component Criteria checklist(Table R402.4.1.1 -
one page)
❑ A completed Envelope Leakage Test Report(usually one page)
❑ If Form R405 duct leakage type indicates anything other than "default leakage", then a completed
Form R405 Duct Leakage Test Report(usually one page)
EnergyGauge@-USRCZB v5.1
11/9/2017 10:13:30 AM Page 1 of 1
CITY OF / / / / BUILDING
ZEPHYRHILLS DEPARTMENT
OF ADDITION OR CORRECTION
D • NOT REMOVE
ADDRESS DATE REKNIT�
THIS JOB HAS NOT BEEN COMPLETED. The following additions or corrections shall be made before the job
will be accepted.
SS�Th- o-, v-tt
It is unlawful for any Carpenter,Contractor,Builder,or other persons,to AFTER CORRECTIONS ARE MADE L
cover or cause to be covered,any part of the work with flooring,lath,earth 780-0020 FOR E- S ECor other material,until the proper inspector has had ample time to approve
the installation.
OFFICE HOURS 7:30AM-4:30 PM MON.-FRI. INSPECTOR
I
5335 - 8TH STREET
(813)780-0020
CERTIFICATE OF OCCUPANCY
Address: 6517 WAGON TRAIL ST Owner: DR HORTON INC
ZEPHYRHILLS, FL. 12602 TELECOM I
Subdiv: SILVERADO TEMPLE TERRAC
Parcel: 05-26-21-0080-00600-0210 Work Type: 101-NEW CONSTI
Construction Type: NOT APPLICABLE ❑ Sprinklers
Use Classification: NOT APPLICABLE
Permit Number: 19590
Date: � U/2018
ISSUED BY• —BUILDIIl
WATER MUST BE CHANGED OVER WITHIN 10 DAYS OF
GARBAGE DEPOSIT MUST BE APPLIED FOR PRIOR TO
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Envelope Leakage Test Report
Prescriptive and Performance Method
Project Name: SILVERADO Builder Name: D R HORTON Street: 6517 Wagon Trail St Permit Office:
City,State,Zip: Zephyrhills,FL 33541 Permit Number:
Design Location: 6517 Wagon Trail St(Lot 21) Jurisdiction:
Cond.Floor Area: 1828 Cond.Volume: tV 15849
Envelope Leakage Test Results Leakage Characteristics
Regression Data:
C: n: R:
CFM(50): 1492
Single or Multi Point Test Data
ELA: 82
HOUSE PRESSURE FLOW:
1 50 Pa 1492 cfm EgLA: 194
ACH: 5.65
2 0 Pa 0 cfm
SLA: .04
3 0 Pa 0 cfm
4 0 Pa 0 cfm ACH(50)*: 5.65
*For prescriptive projects,tested leakage must be—7:
5 0 Pa 0 cfm ACH(50). For performance projects, tested leakage
must be—the ACH(50)shown on Form R405-2014
6 Pa cfm for this project.
R402.4.1.2 Testing.The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zones 1
and 2.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Testing shall be conducted by either individuals as defined in
Section 553.993(5)or(7),Florida Statutes or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party.A written report of the
results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all
penetrations of the building thermal envelope.
During testing:
1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other
2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration
3.Interior doors,if installed at the time of the test,shall be open;
4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed;
5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and
6.Supply and return registers,if installed at the time of the test,shall be fully open.
I hereby certify that the above envelope leakage performance results
demonstrate compliance with Florida Energy Code requirements in
accordance with Section R402.4.1.2.
Testing shall be conducted by either individuals as
defined in Section 553.993(5)or(7), Florida Statutes 0,1-tKES742F
or individuals licensed as set forth in Section
489.105(3)(9,(g),or(i)or an approved third party.A `' _� <O
written report of the results of the test shall be signed —1
Digitally signed by Michael by the third party conducting the test and provided to
Silberstein the code official. ,
Date:2018.09.1913:43:29 EDT ,t
CN=Michael Silberstein,O=TopBuild
Home Services,OU,
EMAI LADDRESS=Mich ael.S ilb erstei
Signature: n@topbuild.wm,C=US
Michael Silberstein BUILDING OFFICIAL:
Printed Name:
Date: 09/19/2018 DATE: ti
I
Thank you for allowing TopBuild the opportunity to provide the above services for you.Please feel free to contact me with any questions.
10/25/2017 396267