HomeMy WebLinkAbout18-19598 CITY OF ZEPHYRHILLS
5335-8TH STREET
(813)780-0020 195 8
BUILDING PERMIT SINGLE FAMILY RESIDENTIAL 7
-PERMIT INFORMATION LOCATION INFORMATION
Permit#:19598 Issued: 5/01/2018 Address: 6630 WAGON TRAIL ST
Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL.
Class of Work: 101-NEW CONST/SFR Township: Range:
Proposed Use: NOT APPLICABLE Lot(s): Block: Section:
Sq. Feet: Est. Value: Book: Page:
Cost: 267,656.40 Total Fees: 14,299.19 Subdivision: SILVERADO
Amount Paid: 14,299.19 Date Paid: 5/01/2018 Parcel Number: 05-26-21-0080-00600-0060
CONTRACTOR INFORMATION OWNER INFORMATION
Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC
Addr: 4600 W. CYPRESS ST STE 200 Address: 4600 W CYPRESS ST STE 200
TAMPA, FL. 33607 TAMPA FL 33607409
Phone: (813)574-5743 Lic: Phone: 813-574-5700
Work Desc: CONSTRUCT SINGLE FAMILY 2,376 SQ FT
'APPLICATION FEES _
BUILDING FEE 1,482.60 ELECTRICAL FEE - - 310.50 PLUMBING FEE 207.00
MECHANICAL FEE 144.90 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00
PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL-SFR NEW 1% 71.28
SCHOOL IMPACT FEE NEW 7,128.00 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32
56�A
��
N
Inspections Required
FOOTER 2ND ROUGH PLUMB Misc INSULATION CEILING
FOOTER BOND DUCTS INSULATED SEWER MISC.
ROUGH ELECTRIC LINTEL MISC MISC.
1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC.
DUCTS INSTALLED WATER MISC DRIVEWAY
PRE-SLAB SHEATHING MISC. MISC.
CONSTRUCTION POLE FRAME MISC. MISC.
REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES:
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing,consult with your lender or an attorney
before recording your notice of commencement.
Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance
with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
n I � i I A &--- f"�*
CO T U R E PERMIT OFFI
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
i
i
__._.. ��.�...�._.._...-_ _���.�„���,.eza.a-_e.•wtisit.r1•a+EtT.i�F;Bb'.c.•�6raTi.'.'ti:.'D.�ii �i.,a�..�---•
c .
� M
When Buildings Talk,Wa Liston.
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING
CONSTRUCTION
Envelope Leakage Test Report
Prescriptive and Performance Method
Project Name: (a 6 Builder Name:
Street: 63b W0.9 Permit Office:
City,State,Zip: Q�hyrh:ll 33s'i f (-'C Permit Nu er: �QSCie
Design Location: Jurisdictio
I
Envelope Leakage Test Results i
i
Single Point Test Data:
HOUSE PRESSURE: - 5-0 FLOW:
e
Leakage Characteristics
CFM(50): � � Pass Fail
19
ACH(50): 533
R402A.1.2 Testing. The building or dwelling unit shalt be tested and verified as having an air leakage rate of not exceeding 7 air
changes per hour In Climate Zones 1 and 2 ...Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50
Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7). Florida Statutes or individuals
licensed as set forth in.Section 489.105(3)(f),(g),or()or an approved third party.A.written report of the results of the test shall be
signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all
penetrations of the building thermal envelope.
. 1.Exteriorwindows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other
Infiltration control measures;
( 2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended. ;
infiltration control measures;
3.Interior doors,if installed at the time of the test,shall be open; ,
4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed;
S.Heating and cooling systems,if Installed at the time of the test,shall be turned oft;and
t
6.Supply and retum registers,if Installed at the time of the test,shall be fully open
. I hereby certify that the above envelope leakage Where required by the code official, testing shall be
performance results demonstrate compliance with, conducted by an approved.third-party. A written report of
Florida Energy Code requirements in accordance with the test results shall be signed by the third party
t section 11402.4.1. . conducting the test and pro ' ed to the code official.
SIGNATURE:
PRINTED NAME: y� BUILDING Fri
yv
DATE: 101, 018 L DATE:
Testing was conducted in accordance with ANSIIRESNETIiCC 380 to mlist thet20117 residential energy code.
kNAJeV_itream° Ultra Blowing Wool Insulation G l G
Attic and Cavity:Wall Card // `` f j . , r)f '7 �. ifi+M6 h-.J4Ve. ev►e:7q-y
flube"P,i1r��.AI i •l�_ )� �fr�U t�/
Batts:and Blankets E t1ip ment.Req wired
When installed stalled In aggwdance with lhe:tnandfactarer's It is recointnended thata- neumatic blovring machine and a corrugated hose witp a minimum Y.'internal clsrrligalibn,a minimum length
p
recommendations,Knauf Insulation Batts and blankets Mil of 150'.Lolls In the hose should not be less than 36"in diameter.Acceptable material feed`W6 is 05 Ibs'imlWe.Recommend_ed teed
provide tlfefull R-value: rate-is 15-25 lbslminute.
R4610e* Minimum_ 76ioknesS Thermal Perfbirrriancti SideWAll and Attic A l.ication
t- pP : )
Tdobtaln an The slated ttferroal reslstari�e,(R-value)i5provided by installing in'acctsrdance with4he manufacturer's instructions.Failure to install the
fnstailed Insulation should, re-uired.numberof ba
insulationrosisr_ance g gsper l,000square feet andezceeding:lfie.maximumsquarefeetaf coverage per.bag asrecommendedbythe,label
not be Jess than::
(R=value)of Mill result In lower.installed R=valu_es:Feld blending•of this product with other Bose fill insulations Is not recommended by the manufacturer.-
R 49 1175" -- - - Cavity:Wall Bag Net Weight=Nominal 31 lbs:,_Minimpm 31 lbs.
R-38HD 10.25" -_-_ - --- - --
R 38 12:00_ _
" R=Vatue� Bags per 1000$F Maximum-, Net Minimum_
R;30HD` 8.25" To,obtalnan The number of bags Coverage per.Bag Weight
_ int4tatioh per 1,000 square feet Contents of this The we,ght,po%square
R-30 . _ _, 10.00 Cavity resistance of net area should not bag should not. feet of installed insulation
._.
- - - -- Framing Depth of
Density, it less than;, cowinore than: should not be loss than:
R-26 9�00"� - --
R-22 -.:fi:50"_. ...-_. 2"x 4" -3:50" R=15 1:8 lbs./cu.ft. 16.4 bags 61.0 sq,ft; 6.525 lbs,
-:
2 x 6a
5:50 R=23_--_. 1.81bs cu:.ft:.- _ _ -25:8.bags_- 38:6sq.ft; 0:825 lbs.
n
R=15HD 3.50"' 2"x8" 7:25" R'31 1:81bs lcu.it. 34,0 bags_ 2-9.4 sq,ft; :1:0881bs;
R-13 150" 2N 10" 9:25" R'1 I-AlbsAu.#, 43.4 bags: 23A sq.ft,• 1,388lbs,
R=11 3.50" •n meaasreslstadce to heat Qaw,'The higher the R'wa ue,Iha grealer01 elm lating paver,To Q61 ft marked R•vaue,it is essential that this insulallm be Insialled`p�opeify,
R-8 2.50" - -
R 181n a 5S�cavity.conforms to nsTht c s65 and Federal Pe Application Bag Net WeightNominal'-32 lbs:,Minimum 31 lbs.
Specification HH-f521F. - Mininturn
- - ----- - - - -- Bagsl •Makirriurn Minimum Initial_ ;Settled
Framing Adjustrneri 1,000 SF Coverage Weight fnstailed Thickness"'
Tocomp ruiate forframing members;Jhe number of bags.per' The number of Ibagsl.. ,contents of this The weight/SF Thickness: Coolants of title
1,000 sq it of area to,be insulated should,be as shown below. R-Value* t;0o11 sF,of Rat area bag should not of Installed. Installed Insulation bag should.
Bags/MSF BagSIMSF To obtain arl Insulation should not be less cover Insulation should not sho__uld_not be less: not:cover more.
reslstanee,(R•Value)oft= than: more than: he.1es3 then than: than:
Joist" 96"O.C. 24":; R-60-- 2t3.7 33,6 SF' 9521bs: 19:750" 19.750"'
R=Value Dimensions Framing Frafnng _. - -_
2x4' 29:2 29:4' ___--k49_ 23.5 42:5 SF7 16.375 16,375 -
R-60 2x6' '28:9 29.;1
R 44 20.9 47,8:SF .670Ibs. - 14.875"- 14:875
2x8 26.6 28.9 R 38 17.8 `56.2§F :569 Ibs: 13.000" 13.000;"
4x4 23:0 23.2.; R=30 13:6 73.3 SF- .437 lbs. 10;375" 10 375"-
R-49 24 22;1 - 22,9, - - R=26; 11.6 8$.0$F . . . .125g 9.125"
2x8 22:A - _ ^22:7 - 377 Ibs 9
- -
2x4 20:4 20.6 - - R-22 ___,_9.8____. _ _, i&_2 SF__- ____.313 lb-s._-J- :7:750" _=7.750"
11-44 2z6_- _ 20.1 20:3 . _ R-:19 8:4• 119 3 SF 268 lbs., ,6.750" 6.750"
=13 - 5.7 170 SF - ..1831bs._ 4.750" 4;750"
2x4 17.3 17,4 R 11 4:7 210.8 SF .152.169. 4.000" -4.000"
1149 24 17;0 17.2 r. -- --
Net Weght�idmiapl321�.;ASrimu<n afros: .. ,
Na _ 16:7 - 17.0• COYd* eendln"slataliondatrefedet-mitreduslj�aVotu•: Ilbbsfigin5c5lue&�thudgearw1n73'gateopaang;20'pila:rpressivezrd159'or,9'titemagytorlir3atedla's9:
Aspmdscl conforms le tlpa performance requ4ements otASTM C 7FA;Typo bend ca"cetled FedEral SpEdtcst.on MH•I.10538:Type 1,Gasse:R•va'ws sredetrpm'neA N soro�danco niN`C 687 and 05tfi.
2x4 13:2, 13.3 R;mr"ns ras stance ohEd{nPN,ThEt QhefdeRY21 ,Ihe grey eraz nsu 36.npggvmcTo yet the mat edRvalua;tk esspda ttatDs ula onb instikdrnopety.I1,you do ayoursol'not inswe .
R=10 _ 2x6 1214 13.1 twna?dro"awlhenca•�t��y,lns uc6ansdortotarwraN ryaprJage
'osseE on Thtld Pany2•ygarselheg SNd/lho predcL�s�p eT•:ntovara2p•y¢arperad wotWgo,l pc�cerd or kss.Tlusan�ml oiu�ng is lkemla!tylnsedmrrant Tferiore Nekrst;lede�seWEd
12.9 mrYnessesaeaNecU e:ylfie same.
2xA .- 11:3 11,4 VeLM1latilliseregsEEdt2CemakoflIn"rsut
R-26 2x6 110 11;2- Builder's Insdlat16n`:Siatement.
2z8 10:& 11.0 Jet Siream Ultra has:beeninstalle_d_in.conformance_wi f h the included recommendations to_provide a.thermal resistance of., _
2x4' _ 9.3 9.5 R=Value Thickness
R-22 2x6 9,1 9,3. _Attic•Area _ _- - - R- at Incites
2x8 - BIB -9:1. = - -
. Sloped Ceilings_ - - 'R- at
-- . -_-... ---. _ 7.9.,
: .__ Ihiiies_
x ' 7:9 81 Walls' a- noFesR-19 2x6 7.7 7.9
-
- -. -
2x8 7A .7.7: Floors(over_arl`unheated crawl space) R- at I,nghes
Craw1:S _ .PN4 53 aeerinn eter - -R: -. .._.. al - - Inches
R=13 24 5.0 62' Datelnstalled ` E
2x8___ _4:8- _. 5.0 Blown insulatibn has been installed in:conformance with the above:rgcpm-en�datjonsao provide an.R-value:of,`.
W. 4:3 4,4_ RSA using t --_.bags of this Instilation3o cover. f - square feet ofarea
-11-11 2x6•• 4.1 4:3:. at a-miJ thickness of• 1- --inches,
2x8 3.8 - 4.1 -
urF".I;o;,,pnr Insulaf qrd ao ore t
{� '� GREENGIIARo hold•". '• - - -'-�' -
UL En imv-n a nd ng UARor6in.1, -
Ut Ea�am�mam GEEEAJGiIARD God or�d h Pa 9 ' `Dale
ULEnrlmgmem<v!ul"kd 1ot416rmcldaliyd•(gym
U_lf-ImiurmGREEN'GUARD Home Builiter(signature)
Frodq,nricsMwd,iUtF'Vf' '
GRFENGUARDo do.d.6 1.amlwt- Company' Date
ml9lcni lnrdlmlo"/olr di*gird R"r ipae. - -- -- -- - -_ _
F"r'nmo Inrd,inoaeri,H,a d.�nrdE3• The coverage informalloq on this'Att1 (Isidewaii car_dapplies'to the entire.tInited Slates(including Minnesota):
_...._�-----.--.•._., .
vrww.kbaufiosulation.us' Knauf InsulaEionInc. One.Knauf-Dnve,Shelb •Y`'ille,W 461- Tel:(800)825*34 ext,:8300 FAX; 317�398-3675
(r10r11F IfnmAF Inculer:nn'Inn
IPASCO COUNTY, FLORIDA
'` " Permit No.
j, l = Date Permitted
Builder Name/Owner Name nG2 r � A, Control#'
County Parcel No, SubDIV; ' 1�WaA0
` .�
AddressfLocaffon ��5b W6Lg6,1. 7�,(tr tf
t5F_
rr
ClassiftcationlType of Use ex 4 f+ r�
TRANSPORTATION IMPACT FEE Rate, Sq.Ft Unit:
Exempt []Yes F1 No How Determined
Impact Fee Amount $. v�t37, Zone No. TAM
SCHOOL IMPACT FEE
Account (056) Single-Family Detached House Amount $ -7, r 2 8vo C1
(057) Mobile Horne
l (4 Other Residential
23)
123} .Collect[an Fee
Exempt [�Yes n No How Determined
PARKS AND RECREATION FEE
�1 Land Account Land Credit Land Total
Recreation Account Recreation Credit Recreation Total
Zone TOTAL AMOUNT $ ��+�•,5.6
Exempt ❑Yes [] No How Determined
LIBRARY FEE
Land Account Land Credit Land Total
Facility Account Facility Credit Facility Total
Exempt []Yes ❑No How Determined Total Amount -�
RESOURCE FEE ERU
TOTAL AMOUNT
Prepared By Checked By
NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION
PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE
BEEN PAID AND
RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY
Acknowledgement below does not impiy acceptance of concurrence,but simply receipt of-a copy of this form,placing
the buAding permit owner on notice of this assessment and tins conditions of payment for some.
DATE RECEIVED 57
RECEIPT NO. DATE BY
CITY OF " NOTICE '
/ BUILDING
ZEPHYRHILLS DEPARTMENT
OF ADDITION OR CORRECTION
D • NOT REMOVE
ADDRESS DATE PERMIT f
THIS JOB HAS NOT BEEN COMPLETED. T14 following additions or corrections shall be made before the job
will be accepted.
7
It is unlawful for any Carpenter,Contractor,Builder,or other persons,to AFTER CORRECTIONS ARE MADE CALL
cover or cause to be covered,any part of the work with flooring,lath,earth 780-0020 FOR RE-INSPECTION
or other material,until the proper inspector has had ample time to approve
the installation.
OFFICE HOURS 7:30AM-4:30 PM MON.-FRI. INSPECTOR
o lN" o
_,rl'1:0IIIUfl 111
City of Zephyrhills
BUILDING PLAN REVIEV�COMMENTS
Contractor/Homeowner: tmm,(—
Date Received: wo
Site: 36 WaVmv
Permit Type: ! 'Z 3
/ � , -7
Approved w/no comments:❑ Approved w/the below comments: Denied w/the below comments: ❑
This comment sheet shall be kept with the permit and/or plans.
Kalvin S itze — ans Examiner Date Contractor and/or Homeowner
(Required when comments are present)
i
Lennar Homes-6630 Wagon Trail St-2,376 sq ft
Column
SQ. FEET PRICE
MAIN OR LIVING: 2,376 $ 112.65
OTHER AREA UNDER ROOF: - $ 88.00
OTHER: - $ -
VALUATION $ 267,656.40
FEE SHEET $ 1,380.00
ADDRESS $ 30.00
DRIVEWAY $ 45.00
BUILDING: $ 1,482.60
ELECTRICAL: $ 310.50
PLUMBING: $ 207.00
MECHANICAL: $ 144.90
SUB-TOTAL $ 2,145.00
TOTAL $ 2,145.00
SEWER: n/a
WATER: n/a
IRRIGATION: $ -
TOTAL: $ -
WATER METER: n/a
IRRIGATION METER $ -
FIRE DEPARTMENT FEES
PLANS TOTAL: n/a
INSPECTION TOTAL:
PERMIT TOTAL
TOTAL: $ -
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
FIRE $ 273.00
5% $ 26.35
TOTAL: $ 553.35
SUB-TOTAL $ 2,698.35
PARK IMPACT FEES $ 769.56
SIF'S: $ 7,128.00
100.0% $ 7,128.00
1.0% $ 71.28
TOTAL: $ 7,199.28
T I F'S: $ 3,632.00
99% $ 3,595.68
1% $ 36.32
TOTAL: $ 14,299.19
Single Singlef ami y we ing
P v Plan Re View Comments
1: Y.F.-E. shall be.a.minimum of 8",above.the road elevation and an-engineered site plan. : -- - .
2. Lots shall-be graded.to comply with R401.3 of the F.B.C.
3. :Compaction test required:if 24"'or more of fill dirt is.btbught•in at any:one place:
4. .Tie in survey required before pouring concrete.
5.. Driveways:require a R.O.W. use permit.. All 4 sides of driveway thru the sidewalk shall.have.
expansion material:
6.. All setbacks shall be met.
-7. All.property markers shall be uncovered and marked at time'of first 'inspection:
8. All A.D.A. requirements shall be met.:.
9. No electric;plumbing,-mechanical;-or-raining shall be covered without an inspection and
approval-first. : .
10. All Garages shall-comply.with:section R302:6 of,the.F.B.0 (Fire Separation)..
11.Appliances shall not be installed in.a location where siibjectto_ineehanical damage unless. '
protected.by approved barriers. :M303.4 o£the F.B:C
12. Water heaters shall comply with sectionT607.3 of the F.R.C.
13.-Foundation supports'for A/C.units shall be raised at least 3" above finished grade,. M1308.1
14. Return air in all bedrooms.F.B.C. M1620.4,.
15. Smoke detectors are.to be installed in accordance:with:R313.1 of the F.B.C.
16: All glazing requirements are.to be in accordance with R308.4 of the F.B:C.
17. All means.of egress are to be in accordance with R311 of the F.B.G. .
18. `.`Green gypsum board" shall not be used-as.a backer in showers or tubs. R702.4.2.F.B.C.
19. Combination-type AFCI breakers_are-required at all.locations requiring an AFCI.type breaker:
20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating
or appliances or an attached garage.:. They shall be.installed in accordancewith-tlie F.B.C:
21. All plumbing,mechanical, and electrical shall be separate from unit to:unit: This includes all
underground plumbing and electric:
22. All 2011.N.E.C: Codes:will be enforced:
23. Tamper- Resistant Receptacles in accordan.ce with 406.11 of the 2011 ME
:C
24:.In accordance.with the Land Development.Code, lots shall be sodded before final at least 10
feet:around the structure:
25. A cony of the energy cacls shall be with,permit at all thnes
26 Cony of final insulatioiz renbrt shall be.prbvided with permit before.fnaL
F.F.E.-Finished Floor Elevation
F.B.C-Florida Building Code'6t'Edition
R.O.W.-Right of Way
A.D,A.-Americans with Disabilities Act . N.E.C.-National Electric.Code(2011).
05-26-21-0080-00600-0060 1 Pasco County Property Appraiser Page 1 of 1
Data Current as Of: Weekly Archive - Saturday, April 21, 2018
Parcel ID 05-26-21-0080-00600-0060 (Card: 001 of 001)
Classification 00 - Vacant Residential
Mailing Address Property Value
LENNAR HOMES LLC Ag Land $0
4600 W CYPRESS ST STE 200 Land $2,413
TAMPA FL 33607-4099 Building $0
Physical Address Extra Features $0
6630 WAGON TRAIL STREET
ZEPHYRHILLS, FL 33541
Just Value $2,413
Legal Description (First 4 Lines) Assessed (Non-School Amendment 1) $2,413
See Plat for this
Subdivision Taxable Value $2,413
SILVERADO RANCH SUBDIVISION
PHASES 6, 8 &9A PB 75 PG 075
BLOCK 6
LOT 6
Jurisdiction
City of Zephyrhills
Land Detail (Card: 001 of 001)
Line Use _ ;Description!Zoning _Units ;Type IPrice _ Condition ;Value
1-� i 01_ ___ 000.00 SF . ; 0.40 ' _1_00 _j_ $2,400
_ -; _ 00 SFR I-MPUD 6, _
2 0100 SFR { MPUD 1 50.00 f SF1 $0.25 i 1.00 $13
Additional Land Information
Acres + 0.14 Tax Area 30SI 1 FEMA ; -- j Residential Code i SLVRCPI
{ I ; Code
Building Information - Use 00 - Unimproved (Card: 001 of 001)
Unimproved Parcel 00 - Unimproved
Extra Features (Card: 001 of 001)
Line Description T Year
-------- -- P — l - _ !Units- - ----- 'Value __----
No Extra Features
Sales History - See All 6 sales
Previous Owner: DUNE FL LAND I SUB LLC
Month/Year Book/Page Type _ -__ ;DOR Code�Condition)Amount
-04/2018 J1I9709 / 2014 f — _ Warranty Deed 5 Vacant Multi-Parcel Sale
---- - - ----- — -- ---- ------
05/2017 12535 / 0546 Certificate of Title F 05 j Vacant Multi-Parcel Sale
11/2016 19462 / 0384 (Mineral Rights or Royalty Transfer!05 Vacant Multi-Parcel Sale
http://search.pascopa.com/parcel.aspx?parcel=2126050080006000060 4/23/2018
813-780-0020 _ - ..City of Zephyrhills Permit Application Fax-813-780-0021
Building Department
Date Received Phone Contact for Permitting [:8=13363 __ 2891
- 1 1 1
Owner's Name Lennar Homes,LLC ',-Owner Phone Number 813.574.5700
4600 W.Cypress St.Ste.200,Tampa,FL 33607.
r Owner's Address 'Owner Phone Number
Fee Simple Titleholder Name Nl Owner Phone Number
Fee Simple Titleholder Address N/A
6630 Wagon Trail Street 0060
JOB ADDRESS g LOT#
SUBDIVISION Sllverado Ranch Subdivision Ph 2,3,&4 PARCEL ID# 05-26-21-0080-00600-0060
(OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED NEW CONSTR e ADD/ALT 0 SIGN Q Q DEMOLISH
INSTALL REPAIR
PROPOSED USE n SFR Q COMM OTHER
TYPE OF CONSTRUCTION BLOCK 0 FRAME STEEL Q
DESCRIPTION OF WORK Single Family Residence/Pool/Screen Enclosure/Fence
BUILDING SIZE U/R SF 2376 SQ FOOTAGE 1936 HEIGHT 1 Story
10BUILDING VALUATION OF TOTAL CONSTRUCTION
Leo
(ELECTRICAL $ ®AMP SERVICE PROGRESS ENERGY Q W.R.E.C.
777 ••• fff
PLUMBING $
MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION
=GAS ROOFING Q SPECIALTY OTHER
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA YES nV0
BUILDER COMPANY
Lennar Homes,LLC
SIGNATURE REGISTERED Y/ N_J FEE CURREN
Address 4600 W.Cypress St.Ste.20 ,Tampa,FL 33607 License# CGC1518166
ELECTRICIAN COMPANY Edmonson Electric, Inc.
SIGNATURE REGISTERED Y/ N FEE CURREN
Address 1034 Skipper Road,Tampa, FL 33613 License# EC13005408
PLUMBER COMPANY I Bayonet Plumbing, Heating &AC, Inc
SIGNATURE REGISTERED Y/ N FEE CURREN Y/N
Address P.O. Box 5308, Bayonet, F 34674-5308 License# I CFC042998
MECHANICAL COMPANY Bayonet Plumbing, Heating &AC,-Inc
SIGNATURE - Ll REGISTERED Y/ N FEE CURREN Y/N
Address P.O. Box 5308, Bayonet, F 4674-5308 License# CAC058062
OTHER COMPANY
SIGNATURE REGISTERED Y/ N FEE CURREN
Address 4211 Shoal Line Blvd, Spring Hill, FL 34607 License# CCC057991
11111111111111111111111111111111111 .IIIIIIIIIIIIIIIIIIIIIIIIII111111
RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction,
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects
COMMERCIAL Attach(2)complete-sets of Building Plans plus-a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction.
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance
SIGN PERMIT Attach(2)sets of Engineered Plans. -
****PROPERTY SURVEY required for all NEW construction.
Directions:
Fill out application completely.
Owner&Contractor sign back of application,notarized
If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500)
** Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (copy of contract required)
Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage)
Driveways-Not over Counter if on public roadways..needs ROW
I
NOTICE OF DEED RESTRICTIONS: The undersigned understands that-this permit may be subject to"deed" restrictions"
which maybe-more restrictive than County regulations. The undersigned assumes responsibility for compliance with any
applicable deed restrictions. - , . ..
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or
contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the
contractor is not licensed as required by law, both-the owner and contractor may be cited for a misdemeanor violation
under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the
intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at M-847- �I
8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign
portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the
contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco
County.
TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of
use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and
90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of
permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to
receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or
final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact
fees are due,they must be paid-prior to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is$2,500.00 or more, I
certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's
Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone
other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to
deliver it to the"owner" prior to commencement.
CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all.the information in this application is accurate and that all work
will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is
hereby made to obtain a permit-to do work and installation as indicated. I certify .that no work or installation has
commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating
construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also
certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is
my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to:
- Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands, Water/Wastewater Treatment.
- Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering
Watercourses.
- Army Corps of Engineers-Seawalls, Docks, Navigable Waterways.
- Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment,
Septic Tanks.
- US Environmental Protection Agency-Asbestos abatement,
- Federal Aviation Authority-Runways.
I understand that the following restrictions apply to the use of fill:
- Use of fill is not allowed in Flood Zone W" unless expressly permitted.
- If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a
"compensating volume" will be submitted at time of permitting which is prepared by a professional engineer
licensed by the State of Florida.
- If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall
construction, I certify that fill will be used only to fill the area within the stem wall.
- If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots less than one (1)
acre which are elevated by fill, an engineered drainage plan is required.
If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in
this affidavit prior to commencing construction: I understand that a separate permit may be required for electrical work,
plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A
permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or
set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter
requiring a correction of errors in.plans, construction or violations of any codes. Every permit issued shall become invalid
unless the work authorized by such.'permit is commenced within six-months of permit issuance, or if work authorized by
the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension
may be requested, in writing, from the Building Official for-a period not to exceed ninety (90) days and will demonstrate
justifiable cause for the extension. If work ceases for ninety(90) consecutive days, the job is considered abandoned.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
FLORIDA JURAT(F.S.117.03)
OWNER OR AGENT CONTRACTOR
Subscribed and sworn to(or affirrKed)before me this Subscribed and s r to(or affirmed)before me this
ov=iarr-1 o by Paul SweeneyY
30-Jan-18 b aul Sweeney
Who is/are personally known to me oil hasihavepradased- Who is/are Person Iv known to me or hasfhave predueed
tification. as identification.
Notary Public Notary Public
Commission No. FF98537 Commission No. FF98537
Elissa M.Holleran Elissa M.Holleran
Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped
- '4�rt�n7ra�nrMr:t'pixlaiGl�' � '
' Il�di�'�Yr�'i7;�ratdt�raa�ll�1g11 � �d+�lilr��'t�ru��tp,�ae�llt�1t1�1'AII
F=124.10
5 + / 123 LOT 46 ti ��,
' PAD=123.4 , �,
,� '' X1z
TYPEto
A v erg , ,zo.o3 Cq
xL 45 `LOT 4,4'
124 t �ti PAD=122.2' ' PAD= 12 5
15' TYPE A PERT 5 , �' YPE TY `
+ ANC pRAINAGE,'>~ASME - ;` !
` Rs �� %x 121.87 - I.
.5.34 t,s ,
!I x 123.83 x 1,23.27
r !
x 124.6
1 , ,
xi 9.601"
'23.6
l'o
Jf ,, ' FF=1 1 .20 , 'F-'118.26
I $+ LqT- 41 LOT2
PA16=117.5 ! PAD-1"t•7.5 ;' 4
,F`F'=118.2 ,/'TYPE A ; ' WOE-A ',
o + 18.42 LOT•40 ; ,!
a'r PAD=118,2 ' LA SCAPI
' ! FEE D TYPE'A ,
1.11;.61
t t 30
LOT 39.�,' ! ,
+ PAD=1/9:6 117 �r4! ,,' 46 • o� ,
TYPE
''A ��!•' '�JI�
.117
,
30
+; LOT; 38 FFx 117.60' ,! '
PAD�119.6 ,J + ; „s.6 ,, •,� LOT 3 `!
�o TYPE A !` ,!f'AD=116,3 F
c°> ,! '`�!',�+14f'' '� , ` ,J ,/ I r TYPE ,B
+ • , ,, . , rfig F
a 18 i
+ - FF,=l 70; aye, 6. 6 ; ` Re
+ r'� 'LOT 37" +
o, ,'" , ' ,PAD 418 a '+ ! +
2. TE A PAD 1 g 6.1 '
' t s Xi l�.43
LOT !
16-30
CL k 3 6 ! ` - NIX
FAD=115.6 LOT' $
w _.F' i %`� TYPE A - �Tt + ;' PAD=1A 5.1 It
o I .03 �. ,`' �3, �: TYPE B fIt
}, ,
�� r 114.63'115.30
o + �'' LOT 35
o t ` PAD=114.6 ell , N
VF-114 80
T+
5) I i :''l 't TYPE A ,' ,�'I� + ;' PA 1.
-
1 1t , Ff-114.40 ;tf, t
N
LOo3 14A9 F10
PAP—
LOT 7
IN1 TTYPE o
PAD=11'3.2 t
c
N
11`dT' 330
" + iAD=112.9 !+� l� ilii 1T 3610�
o �,�°` ,, �'� TYPE A /'T}T. i� RAD 112.4 -F
o t• a� �� TYPE S
0 nh +
o
i
i ,
2018072024
Rept:1952755 Rec: 10.00
DS: 0.00 IT: 0.00
04/30/2018 K. A. , Dpty Clerk
LA S.0'NEIL,Ph..DqD.PASCO CLERK & COh1PTROLLER
04OR BK° 9716 PG 2066
Permit No. Parcel ID No 05-26-21-0080-00600-0060
NOTICE OF COMMENCEMENT
State of Florida County of Pasco
THE UNDERSIGNED hereby gives notice that-improvement will be made to certain real property,and in accordance with Chapter 713,Florida Statutes,
the following information is provided in this Notice of Commencement:
1. Description of Property: Legal SILVERADO RANCH SUBDIVISION PHASES 6,8&9A PB 75 PG 75 BLOCK 06 LOT 06
Street Address: 6630 Wagon Trail Street Zephryhills FL 33541
2. General Description of Improvement Single Family Residence/Pool/Screen Enclosure/Fence
3. Owner Information: Lennar Homes, LLC.
Name
4600 W Cypress St, Ste 200 Tampa FL. 33607
Address City State
Interest in Property:
Name of Fee Simple Titleholder: N/A
(If other than owner)
Address City State
4. Contractor: Lennar Homes, LLC
Name
4600 W Cypress St, Ste 200 Tampa FL, 33607
Address City State
Contractor's Telephone No.: 813.574.5700
5. Surety: N/A
Name
Address City State
Amount of Bond: $ Telephone No.:
6. Lender: N/A
Name
Address City State
Lender's Telephone No.:
7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by
Section 713.13(1)(a)(7),Florida Statutes:
Lennar Homes, LLC
Name
4600 W Cypress St, Ste 200 Tampa FL, 33607
Address - City State
Telephone Number of Designated Person: 813.574.5700
8. In addition to himself,the owner designates N/A of
to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statutes.
Telephone Number of Person or Entity Designated by Owner:
9. Expiration date of Notice of Commencement is one year from the date of recording unless a different date is specified:
WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT
ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE
RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT.
STATE OF FLORIDA
COUNTY OF PINELLAS
Signature of Owner or Owner's Authorized Officer/Director/Partner/Manager
Vice President
Signatory's Title/Office
The foregoing instrument was acknowledged before me this 30 day of March ,by
Steve Robert Smith as Vice President (type of a orit ,e.g.,officer,tr ee,attorney in fact)for
Lennar Homes LLC me of arty on behalf instrument was executed).
Personally Known I OR Produced Identification❑ Nota Signature
Type of Identification Produced Name(Print) Elissa olleran
Verification pursuant to Section 92.525,Florida Statutes. Under penalties of perjury,I declare that I have read the foregoing and that the facts stated in
it are true to the best of my knowledge and belief.
' ELISSAM.HOLLERAN Signature of Natural Person Signing Above
C+mmlealon�FF 8B583T-.
Expires dune 6,2020
wpdata/bcs/bcsform: Bonded ThNTroyFolnl Munncet00�0.€701D
�� • ��'� tTATE OF FLOROA,COUNTY OF PASCo
®®�^ THIS IS TO CERTIFY THAT THE FOREG01MCa IS A
' q TRUE AND CORRECT COPY OF THE DOCUMENT
ON.FILE'OR OF PUBLIC RECORD IN THIS OFFICE
rnGod've 7r'l4` WITNESS MY HAND AND FFICIAL SEALTH�IS�
° 2
DAY OF �3
' ppU q S,O'NEIL,CLER &COMPTROLLER
e
188 DEPUTY CLERK
OF
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: 1941A1 sf ADS Builder Name: Lennar Homes
Street: 6630 Wagon Trail Street Permit office: City of Zephyrhills
City,State,Zip: Zephyrhills,FL, Permit Number: 11516
Owner. Lennar Homes Jurisdiction:611600
Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(1961.3 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1454.60 ft2
b.Frame-Wood,Adjacent R=11.0 506.78 ft2
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 4 d.N/A R= ft2
5. Is this a worst case? Yes 10.Ceiling Types (1936.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1936.00 ft2
6. Conditioned floor area above grade(ft2) 1936 b.N/A R= ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ft2
11.Ducts R ft2
7. Windows(157.3 sqft.) Description Area a.Sup:Attic,Ret:family rm,AH:laundry rm 6 387.2
a. U-Factor. Dbl,U=0.54 101.00 ft2
SHGC: SHGC=0.31
b. U-Factor: Dbl,U=0.56 33.33 ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.32 a.Central Unit 34.2 SEER:15.00
c. U-Factor: Dbl,U=0.56 23.00 ft2
SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a.Electric Heat Pump 32.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 1.212 ft.
Area Weighted Average SHGC: 0.308 14.Hot water systems
8. Floor Types (1936.0 sqft.) Insulation Area a.Electric Cap:40 gallons
a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ft2 b. Conservation features EF:0.950
b.N/A R= ft2 None
c.N/A R= ft2 15.Credits Pstat
Glass/Floor Area: 0.081 Total Proposed Modified Loads: 62.58 PASS
Total Baseline Loads: 62.81
hereby certify that the plans and specifications covered by Review of the plans and :Tl Sxr.
4 y
this calculation are in compliance with the Florida Energy specifications covered by this
Code. calculation indicates compliance '
_?a,,
with the Florida Energy Code.
PREPARED BY: Davy ,upich Before construction is completed
DATE: this buildingwill be inspected for
P
compliance with Section 553.908
herebycertify that this building,as designed, is in compliance Florida Statutes. .S
fY 9, 9 P .'� .-.... .
with the Florida Energy Code.
OWNER/AGENT: CHECKE0 FEg 0 min BUILDING F L:
DATE: DATE: _
- Compliance requires certification by the air handler ur it manufacturer that the air handier enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Insp ction Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage'no c eater than 6.50 ACH50(R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.030 Qn for whole house.
2/1/2018 7:42 AM EnergyGauge@ USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 6
9
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: 1941A1 sf ADS Builder Name: Lennar Homes
Street: 6630 Wagon Trail Street Permit Office: City of Zephyrhills
City,State,Zip: Zephyrhills,FL, Permit Number:
Owner: Lennar Homes Jurisdiction:611600
Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(1961.3 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block'-Int Insul,Exterior R=4.1 1454.60 ft2
b.Frame-Wood,Adjacent R=11.0 506.78 ftz
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 4 d.N/A R= ftz
5. Is this a worst case? Yes 10.Ceiling Types (1936.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1936.00 ft2
6. Conditioned floor area above grade(ft2) 1936 b.N/A R= ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ft2
11.Ducts R ft2
7. Windows(157.3 sqft.) Description Area a.Sup:Attic,Ret:family rm,AH:laundry rm 6 387.2
a. U-Factor: Dbl,U=0.54 101.00 ft2
SHGC: SHGC=0.31
b. U-Factor: Dbl,U=0.56 33.33 ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.32 a.Central Unit 34.2 SEER:15.00
c. U-Factor: Dbl,U=0.56 23.00 ft2
SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a.Electric Heat Pump 32.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 1.212 ft.
Area Weighted Average SHGC: 0.308 14.Hot water systems
8. Floor Types (1936.0 sqft.) Insulation Area a.Electric Cap:40 gallons
a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ft2 b. Conservation features EF:0.950
b.N/A R= ft2 None
c.N/A R= ft2 15.Credits Pstat
Glass/Floor Area: 0.081 Total Proposed Modified Loads: 62.58 PASS
Total Baseline Loads: 62.81
I hereby certify that the plans and specifications covered by Review of the plans and
this calculation are in compliance with the Florida Energy specifications covered by this -p
Code. calculation indicates compliance
with the Florida Energy Code. , rFrri: .'? r�' wa
PREPARED BY: Davy ><{COI ch Before construction is completed
DATE: this building will be inspected for ) _
compliance with Section 553.908 i .
herebycertify that this building,as designed,is in compliance Florida Statutes.
fY 9� 9 P �with the Florida Energy Code.
OWNER/AGENT: BUILDING FI IAL:
DATE: DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 6.50 ACH50(R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage.Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house.
2/1/2018 7:42 AM EnergyGaugeO USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 6
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: 1941A1 sf ADS Builder Name: Lennar Homes
Street: 6630 Wagon Trail Street Permit Office: City of Zephyrhills
City,State,Zip: Zephyrhills,FL, Permit Number:
Owner: Lennar Homes Jurisdiction:611600
Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(1961.3 sgft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1454.60 ft2
b.Frame-Wood,Adjacent R=11.0 506.78 ft2
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 4 d.N/A R= ft2
5. Is this a worst case? Yes 10.Ceiling Types (1936.0 sqft.) Insulation Area
a.Under Attic(Vented) R=30.0 1936.00 ft2
6. Conditioned floor area above grade(ft2) 1936 b.N/A R= ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ft2
11.Ducts R ft2 �
7. Windows(157.3 sgft.) Description Area a.Sup:Attic,Ret:family rm,AH:laundry rm 6 387.2
a. U-Factor: Dbl;U=0.54 101.00 ft2
SHGC: SHGC=0.31
b. U-Factor: Dbl,U=0.56 33.33 ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.32 a.Central Unit 34.2 SEER:15.00
c. U-Factor. Dbl,U=0.56 23.00 ft2
SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a.Electric Heat Pump 32.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 1.212 ft.
Area Weighted Average SHGC: 0.308 14.Hot water systems
8. Floor Types (1936.0 sgft.) Insulation Area a.Electric Cap:40 gallons
EF:0.950
a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ft2 b. Conservation features
b.N/A R= ft2 None
c.N/A R= ft2 15.Credits Pstat
Glass/Floor Area: 0.081 Total Proposed Modified Loads: 62.58 PASS
Total Baseline Loads: 62.81
I hereby certify that the plans and specifications covered by Review of the plans andTk :$T�q
this calculation are in compliance with the Florida Energy specifications covered by this
Code. calculation indicates compliance �t
with the Florida Energy Code. ti, rrrrr" '?% ? :��`t-°,. 0
PREPARED BY: Dave Mkh Before construction is completed
DATE: this building will be inspected for -T
compliance with Section 553.908
Florida Statutes.
I hereby certify that this building,as designed, is in compliance
with the Florida Energy Code. Oa
OWNER/AGENT: BUILDING OF ICIAI
DATE: DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 6.50 ACH50(R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.030 Qn for whole house.
2/1/2018 7:42 AM EnergyGaugeO USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 6
FORM R405-2017
PROJECT
Title: 1941A1 sf ADS Bedrooms: 4 Address Type: Street Address
Building Type: User Conditioned Area: 1936 Lot#
Owner Name: Lennar Homes Total Stories: 1 Block/Subdivision:
#of Units: 1 Worst Case: Yes PlatBook:
Builder Name: Lennar Homes Rotate Angle: 45 Street:
Permit Office: Cross Ventilation: No County: Pasco
Jurisdiction: Whole House Fan: No City,State,Zip: Zephyrhills,
Family Type: Single-family FL,
New/Existing: New(From Plans)
Comment:
CLIMATE
Design Temp Int Design Temp Heating Design Daily Temp
Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,Tampa FL_TAMPA INTERNATI 39 91 70 75 645.5 54 Medium
BLOCKS
Number Name Area Volume
1 Entire House 1936 16360.3
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
1 master 210 1680 No 2 1 1 1 Yes_ Yes Yes
2 family rm 341 3171.3 No 0 1 Yes Yes Yes
3 cafe 161 1288 No 0 1 Yes Yes Yes
4 kit 182 1692.6 Yes 0 1 Yes Yes Yes
5 bdrm2 147 1176 No 1 1 1 Yes Yes Yes
6 bdrm3 149 1192 No 1 1 1 Yes Yes Yes
7 bath2 61 488 No 0 1 Yes Yes Yes
8 bdrm4 149 1192 No 1 1 1 Yes Yes Yes
9 o wic 104 832 No 0 1 Yes Yes Yes
10 privy 24 192 No 0 1 Yes Yes Yes
11 o bath 117 936 No 0 1 Yes Yes Yes
12 laundry rm 100 800 No 0 1 Yes Yes Yes
13 foyer 148 1376.4 No 0 1 Yes Yes Yes
14 hall 43 344- No 0 1 Yes Yes Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
i
1 Slab-On-Grade Edge Insulatio master 29.5 ft 0 212.3 ft2 0 0 1
2 Slab-On-Grade Edge Insulatio family rm 14.5 ft 0 340.8 ft2 -__ 0 0 1
3Slab-On-Grade Edge Insulatio cafe 25.5 ft 0 161 ft2 0 0 1
4 Slab-On-Grade Edge Insulatio kit 13.5 ft 0 182.3 ft2 1 0 0
2/1/2018 7:42 AM EnergyGaugeO USA-FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 6
FORM R405-2017
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
5 Slab-On-Grade Edge Insulatio bdrm2 10.5 ft 0 146.8 ft2 -__ 0 0 1
6 Slab-On-Grade Edge Insulatio bdrm3 13.5 ft 0 y 148.5 ft2 0 0 1
7 Slab-On-Grade Edge Insulatio bath2 5.5 ft 0 60.5 ft2 - 1 0 0
8 Slab-On-Grade Edge Insulatio bdrm4 35.5 ft 0 148.5 ft2 - 0 0 1
9 Slab-On-Grade Edge Insulatio o wic 21 ft 0 104 ft2 0 0 1
10SIab-On-Grade Edge Insulatio privy 1 ft 0 24 ft2 1 0 0
11SIab-On-Grade Edge Insulatio o bath 10.5 ft 0 117.3 ft2 1 0 0
12SIab-On-Grade Edge Insulatio laundry rm 9 ft 0 100 ft2 ee 1 0 0
\ 13SIab-On-Grade Edge Insulatio foyer 22.5 ft 0 147.5 ft2 1 0 0
14SIab-On-Grade Edge Insulatio hall 2 ft 0 42.5 ft2 0 0 1
ROOF
Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
# Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
1 Hip Composition shingles 2097 ft2 0 ft2 Medium 0.85 No 0.9 No 0 22.6
ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Vented 300 1936 ft2 N N
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Vented) master 30 Blown 210 ft2 0.1 Wood
2 Under Attic(Vented) family rm 30 Blown 341 ft2 0.1 Wood
3 Under Attic(Vented) cafe 30 Blown 161 ft2 0.1 Wood
4 Under Attic(Vented) kit 30 Blown 182 ft2 0.1 Wood
5 Under Attic(Vented) bdrm2 30 Blown 147 ft2 0.1 Wood
6 Under Attic(Vented) bdrm3 30 Blown 149 ft2 0.1 Wood
i
7 Under Attic(Vented) bath2 30 Blown 61 ft2 0.1 Wood
8 Under Attic(Vented) bdrm4 30 Blown 149 ft2 0.1 Wood
9 Under Attic(Vented) o wic 30 Blown 104 ft2 0.1 Wood
10 Under Attic(Vented) privy 30 Blown 24 ft2 0.1 Wood
11 Under Attic(Vented) o bath 30 Blown _ 117 ft2 0.1 Wood
12. Under Attic(Vented) laundry rm 30 Blown 100 ft2 0.1 Wood
13 Under Attic(Vented) foyer 30 Blown 148 ft2 0.1 Wood
14 Under Attic(Vented) hall 30 Blown 43 ft2 0.1 Wood
2/1/2018 7:42 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 6
FORM R405-2017
WALLS
Adjacent Space Cavity Width Height Sheathing Framing Solar Below# Ornt In W-all Type
1 S=>SW Exterior Concrete Block-Int Insul master 4.1 12 6 8 0 100.0 ft2 0 0 0.6 0
2 W=>NW Exterior Concrete Block-Int Insul master 4.1 17 0 8 0 136.0 ft2 0 0 0.6 0
3 S=>SW Exterior Concrete Block-Int Insul family rm 4.1 14 6 9 4 135.3 ft2 0 0 0.6 0
4 E=>SE Exterior Concrete Block-Int Insul cafe 4.1 12 .0 8 0 96.0 ft2 0 0 0.6 0
5 S=>SW Exterior Concrete Block-Int Insul cafe 4.1 13 6 8 0 108.0 ft2 0 0 0.6 0
6 E=>SE Exterior Concrete Block-Int Insul kit 4.1 13 6 9 4 126.0 ft2 0 0 0.6 0
7 E=>SE Exterior Concrete Block-Int Insul bdrm2 4.1 10 6 8 0 84.0 ft2 0 0 0.6 0
8 E=>SE Exterior Concrete Block-Int Insul bdrm3 4.1 13 6 8 0 108.0 ft2 0 0 0.6 0
9 E=>SE Exterior Concrete Block-Int Insul bath2 4.1 5 6 8 0 44.0 ft2 0 0 0.6 0
10 N=>NE Exterior Concrete Block-Int Insul bdrm4 4.1 13 6 8 0 108.0 ft2 0 0 0.6 0
11 E=>SE Exterior Concrete Block-Int Insul bdrm4 4.1 11 0 8 0 88.0 ft2 0 0 0.6 0
12 W=>NW Exterior Concrete Block-Int Insul bdrm4 4.1 11 0 8 0 88.0 ft2 0 0 0.6 0
13 N=>NE Garage Frame-Wood o wic 11 28 4 8 0 226.7 ft2 0 0.25 0.01 0
14 W=>NW Exterior Concrete Block-Int Insul o wic 4.1 8 0 8 0 64.0 ft2 0 0 0.6 0
15 W=>NW Exterior Concrete Block-Int Insul o bath 4.1 10 6 8 0 84.0 ft2 0 0 0.6 0
16 N=>NE Garage Frame-Wood laundry rm 11 17 5 8 0 139.3 ft2 0 0.25 0.01 0
17 N=>NE Exterior Concrete Block-Int Insul foyer 4.1 5 0 9 4 46.7 ft2 0 0 0.6 0
_18 W=>NW Garage Frame-Wood foyer 11 15 1 9 4 140.8 ft2 0 0.25 0.01 0
_19 W=>NW Exterior Concrete Block-Int Insul foyer 4.1 2 5 9 4 22.6 ft2 0 0 0.6 0
20 W=>NW Exterior Concrete Block-Int Insul hall 4.1 2 0 8 0 16.0 ft2 0 0 0.6 0
DOORS
# Ornt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 N=>NE Wood laundry rm None .4 2 8 6 8 17.8 ft2
2 N=>NE Insulated foyer None .2 3 6 8 20 ft2
WINDOWS
Orientation shown is the entered orientation(=>)changed to Worst Case.
Wall Overhang
# Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening
1 S=>SW 1 Metal Low-E Double Yes 0.54 0.31 N 23.0 ft2 1 ft 0 in 0 ft 10 in None None
2 S=>SW 3 Metal Low-E Double Yes 0.54 0.31 N 46.0 ft2 1 ft 0 in 0 ft 10 in None None
i
3 S=>SW 5 Metal Low-E Double Yes 0.56 0.32 N 33.3 ft2 2 ft 0 in 0 ft 4 in None None
4 E=>SE 7 Metal Low-E Double Yes 0.54 0.31 N 16.0 ft2 1 ft 0 in 0 ft 10 in None None
5 E=>SE 8 Metal Low-E Double Yes 0.54 0.31 N 16.0 ft2 1 ft 0 in 0 ft 10 in None None
6 N=>NE 10 Metal Low-E Double Yes 0.56 0.28 N 23.0 ft2 1 ft 0 in 4 ft 0 in None None
2/1/2018 7:42 AM EnergyGaugeO USA-FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 6
r
FORM R405-2017
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation,
1 416ft2 416ft2 43.7ft 8ft 1
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000349 1772.4 97.3 182.99 .2618 6.5
HEATING SYSTEM
# System Type Subtype Efficiency Capacity Block Ducts
1 Electric Heat Pump/ Split HSPF:8.5 32.8 kBtu/hr 1 sys#1
COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit/ Split SEER:15 34.2 kBtu/hr 1026 cfm 0.85 1 sys#1
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.95 40 gal 70 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None ft2
DUCTS
—Supply— —Return— Air CFM 25 CFM25 HVAC#
# Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 387.2 ft family rm 96.8 ft2 Proposed Qn laundry rm —cfm 58.1 cfm 0.03 0.50 1 1
I
2/1/2018 7:42 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 6
FORM R405-2017
TEMPERATURES
Programable Thermostat:Y Ceiling Fans:
Cooling [ ]Jan Feb Mar A r May (X]Jun Jul rj Au �Xj Se ]Oct Nov Dec
Heatin ( Jan Feb x Mar Apr May [ ]Jun Jul [ ]Aug SepOct XNov Dec
Ventin [ ]Jan Feb X Mar [X A r [ Ma [ ]Jun Jul [ ]Au Se [X]Oct X Nov Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 .4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 .78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
f
2/1/2018 7:42 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 6 of.6
FORM R405-2017
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 100
The lower the EnergyPerformance Index, the more efficient the home.
Zephyrhills, FL,
1. New construction or existing New(From Plans) 9. Wall Types Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1454.60 ft2
b.Frame-Wood,Adjacent R=11.0 506.78 ft2
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 4 d.N/A R=
2
10.Ceiling Types Insulation Area
5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1936.00 ft2
6. Conditioned floor area(ft2) 1936 b.N/A R= ft2
7. Windows- Description Area c.N/A R= ft2
a. U-Factor: Dbl,U=0.54 101.00 ft2 11.Ducts R ft2
a.Sup:Attic,Ret:family rm,AH:laundry rm 6 387.2
SHGC: SHGC=0.31
b. U-Factor: Dbl,U=0.56 33.33 ft2
SHGC: SHGC=0.32 12.Cooling systems kBtu/hr Efficiency
c. U-Factor. Dbl,U=0.56 23.00 ft2 a.Central Unit 34.2 SEER:15.00
SHGC: SHGC=0.28
d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency
SHGC: a.Electric Heat Pump 32.8 HSPF:8.50
Area Weighted Average Overhang Depth: 1.212 ft.
Area Weighted Average SHGC: 0.308
8. Floor Types Insulation Area 14.Hot water systems Ca :40 gallons
a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ft2 a.Electric p ns
E g 0.95
ns
b.N/A R= ft2
c.N/A R= ft2 b. Conservation features
None
15.Credits Pstat
certify that this home has complied with the Florida Energy Efficiency Code for Building Sc�HESR.
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed y4}",,,;`'� •_; ,.�:'�'+
based on installed Code c mpliant features.
rA
Builder Signature: Date: 02/01/18
Address of New Home: 6630 Wagon Trail Street City/FL Zip: Zephyrhills FL 33541 . �• � � 5
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at
techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of
certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building
Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
2/1/2018 7:43 AM EnergyGauge®USA-FlaRes2017 -Section R405.4.1 Compliant Software Page 1 of 1
Building Anal Job: 1941A1 sf ADS
g Analysis y Date: 211/2018
Entire House By: Dave
Bayonet Plumbing Heating and Air
Project Information
For: Lennar Homes
Design Conditions
Location: Indoor: Heating Cooling
Tampa International AP, FL, US Indoor temperature(°F) 70 75
Elevation: 10 ft Design TD (°F) 39 16
Latitude: 28°N Relative humidity (%) 50 50
Outdoor: Heating Cooling Moisture difference(gr/lb) 34.7 54.7
Dry bulb(°F) 31 91 Infiltration:
Daily range(°F) - 14 ( L ) Method Simplified
Wet bulb(°F) - 77 Construction quality Semi-tight
Wind speed (mph) 15.0 7.5 Fireplaces 0
Component Btuh/ft2 Btuh % of load
Walls 5.6 7036 24.6 ��
Glazing 30.2 4709 16.5 W10ther
Doors 23.5 466 1.6 nfiltration
Ceilings 1.3 2429 8.5
Floors 3.5 6726 23.5
Infiltration 2.8 3996 14.0
Ducts 3223 11.3
Piping 0 0 Glazing
Humidification 0 0 Floors
Ventilation 0 0 Ceilings
Adjustments 0
Total 28584 100.0
Component Btuh/ft2 Btuh % of load
Walls 2.8 3500 13.4 Walls
Glazing 56.7 8852 34.0 Internal Gains
Doors 18.4 365 1.4
Ceilings 1.7 3358 12.9
Floors 0 0 0
Infiltration 0.6 880 3.4
Ducts 3621 13.9
Ventilation 0 0 Ducts
Internal gains 5455 21.0 Glazing
Blower 0 0 Infiltration
Adjustments 0
Total 26030 100.01 Other Ceilings
Latent Cooling Load=4171 Btuh
Overall U-value= 0.103 Btuh/ft2-°F
Data entries checked.
wri9 htsoft' 2018-Feb-0107:29:57
ACCA Right-Suite®Universal 2017 17.0.23 RSU05714 Page 1
...ith CBA27UHE AH's%1941 sfADS template 3ton.rup Calc=MJ8 Front Door faces: W
Project Summary Job: 1941A1 sf ADS
Date: 211I2018
Entire House By: Dave
Bayonet Plumbing Heating and Air
Project Inf• •
For: Lennar Homes
Notes: 2017
Design Information
Weather: Tampa International AP, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 31 OF Outside db 91 OF
Inside db 70' OF Inside db 75 OF
Design TD 39 OF Design TD 16 OF
Daily range L
Relative humidity 50 %
Moisture difference 55 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 25361 Btuh Structure 22409 Btuh
Ducts 3223 Btuh Ducts 3621 Btuh
Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh
(none) (none)
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 28584 Btuh Use manufacturer's data y
Rate/swing multiplier 1.00
Infiltration Equipment sensible load 26030 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Semi-tight
Fireplaces 0 Structure 3525 Btuh
Ducts 646 Btuh
Central vent(0 cfm) 0 Btuh
Heating Cooling (none)
Area(ftz) 1936 1936 Equipment latent load 4171 Btuh
Volume(ft') 16360 16360
Air changes/hour 0.34 0.18 Equipment Total Load (Sen+Lat) 30201 Btuh
Equiv.AVF (cfm) 93 49 Req. total capacity at 0.85 SHR 2.6 ton
Heating Equipment Summary Cooling Equipment Summary
Make Lennox Make Lennox
Trade 14HPX SERIES Trade 14HPX SERIES
Model 14HPX-036-230-21 Cond 14HPX-036-230-21
AHRI ref 10258589 Coil CBA27UHE-036-230*++TDR
AHRI ref 10258589
Efficiency 8.5 HSPF Efficiency 12.5 EER, 15 SEER
Heating input Sensible cooling 29580 Btuh
Heating output 32800 Btuh @ 47°F Latent cooling 5220 Btuh
Temperature rise 25 OF Total cooling 34800 Btuh
Actual'air flow 1200 cfm Actual air flow 1200 cfm
Air flow factor 0.042 cfm/Btuh Air flow factor 0.046 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.86
Capacity balance point=29 OF
Backup: n/a n/a
Input= 0 kW, Output= 0 Btuh, 100 AFUE
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
- wrightsoftm 2018-Feb-01 07:29:57
.�_ Right-Suite®Universal 2017 17.0.23 RSU05714 Page 1
��` ...ith CBA27UHE AH's\1941 sf ADS template 3ton.rup Cale=MJ8 Front Door faces: W
Manual S Compliance Report Job: 1941A1 sf ADS
p p Date: 2/1/2018
Entire House By: Dave
Bayonet Plumbing Heating and Air
Project Information
For: Lennar Homes
Cooling Equipment
Design Conditions
Outdoor design DB: 91XF Sensible gain: 26030 Btuh Entering coil DB: 75.6°F
Outdoor design WB: 77XF Latent gain: 4171 Btuh Entering coil WB: 62.8°F
Indoor design DB: 75.0°F Total gain: 30201 Btuh
Indoor RH: 50% Estimated airflow: 1200 cfm
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: SpIitASHP
Manufacturer. Lennox Model: 14HPX-036-230-21+CBA27UHE-036-230*++TDR
Actual airflow: 1200 cfm
Sensible capacity: 29070 Btuh 112% of load
Latent capacity: 5130 Btuh 123% of load
Total capacity: 34200 Btuh 113% of load SHR: 85%
Heating Equipment
Design Conditions
Outdoor design DB: 30.8°F Heat loss: 28584 Btuh Entering coil DB: 69.7°F
Indoor design DB: 70.0°F
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: SpIitASHP
Manufacturer: Lennox Model: 14HPX-036-230-21+CBA27UHE-036-230*++TDR
Actual airflow: 1200 cfm
Output capacity: 32800 Btuh 115% of load Capacity balance: 29 °F
Supplemental heat required: 0 Btuh Economic balance: -99 °F
i
Backup equipment type: Elec strip
Manufacturer: n/a Model: n/a+n/a
Actual airflow: 1200 cfm
Output capacity: 0 kW 0% of load Temp. rise: 0 °F
Meets are all requirements of ACCA Manual S.
wri htsoft® 2018-Feb-01 07:29:57
9 Right-Suite®Universal 2017 17.0.23 RBU05714 Page 1
A'(;k ...ith CBA27UHE AH's%1941 sf ADS template 3ton.rup Calc=MJ8 Front Door faces: W
PASCO COUNTY, FLORIDA
f
Permit No.
Date Permitted
Builder Name/Owner Name 62::Ir A .S 6 �C- Control#
County Parcel No. 6-5-Z6Z(-608o-66&go-.6Qk0 SubDly: i w-dD
r
Address/Location 7K4f s I
lf t
Classification[Type of Use
TRANSPORTATION IMPACT FEE • Rate: Sq.FtUnit: 2r37b
Exempt ❑Yes ❑ No How Determined
Impact Fee Amount $. , �. 6�_ Zone No. TAZ:
SCHOOL IMPACT FEE
Account (056) Single-Family Detached House Amount $ �t (/2 'i•0 r�
(057) Mobile Home
(058) Other Residential
d
23) Collection Fee
Exempt Yes ❑ No How Determined
PARKS AND RECREATION FEE
Land Account Land Credit Land Total
Recreation Account Recreation Credit Recreation Total
Zone TOTAL AMOUNT $•71 j-S.-
Exempt ❑Yes ❑ No How Determined
LIBRARY FEE
i Land Account Land Credit Land Total
Facility Account Facility Credit Facility Total
Exempt ❑Yes ❑ No How Determined Total Amount `
RESOURCE FEE ERU
TOTAL AMOUNT
Prepared By Qbu� ___ Checked By
NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION
PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE
BEEN PAID AND
RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY
Acknowledgement below does not Imply acceptance of concurrence,but simply receipt of a'copy of this form,placing
the building permit owner on notice of this assessment and the conditions of payment for same.
� r
l�
• r
} DATE RECEIVED BY
RECEIPT NO. DATE BY
` i
5335 - 8TH STREET
(813)780-0020
CERTIFICATE OF,OCCUPANCY
Address: 6630 WAGON TRAIL ST Owner: LENNAR HOMES LLC
ZEPHYRHILLS, FL. 4600 W CYPRESS ST STE 200
Subdiv: SILVERADO TAMPA FL 33607409
Parcel: 05-26-21-0080-00600-0060 Work Type: 101-NEW CONST/SFR
Construction Type: NOT APPLICABLE ❑ Sprinklers
Use Classification: NOT APPLICABLE
Permit Number: 19598
Dat 7/30/2018
ISS ED BY: BUILDI OFFICIAL :
WATER MUST BE CHANGED OVER WITHIN 10 DAYS OF ISSUANCE
GARBAGE DEPOSIT MUST BE APPLIED FOR PRIOR TO ISSUANCE