Loading...
HomeMy WebLinkAbout18-19600 CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 19600 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL PERMIT INFORMATION LOCATION°INFORMATION = Permit#:19600 Issued: 5/01/2018 Address: 6652 WAGON TRAIL ST Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS,'FL. Class of Work: 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost:_ 256,391.40 Total Fees: 14,216.69 Subdivision: SILVERADO Amount Paid: 14,216.69 Date Paid: 5/01/2018 Parcel Number: 05-26-21-0080-00600-0040 CONTRACTOR INFORMATION OWNER INFORMATION Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC Addr: 4600 W. CYPRESS ST STE 200 Address: 4600 W CYPRESS ST STE 200 TAMPA, FL. 33607 TAMPA FL 33607-4099 Phone: (813)574-5743 Lic: Phone: 813-574-5700 Work Desc: CONSTRUCT SINGLE FAMILY 2.276 SQ FT APPLICATION FEES BUILDING FEE 1,426.49 ELECTRICAL FEE 298.13 PLUMBING FEE 198.75 MECHANICAL FEE 139.13 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE NEW 7,128.00 SCHOOL-SFR NEW 1% 71.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32 10,kI-L T c� Inspections Re uire FOOTER 2ND ROUGH PLUMB Misc INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80_(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CON _Ct'0_RS'Sfd_N,AN_URt PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER 05-26-21-0080-00600-0040 Pasco County Property Appraiser ' Page 1 of 1 Data Current as Of: Weekly Archive -.Saturday, April 21, 2018 Parcel ID 05-26-21-0080-00600-0040 (Card: 001 of 001) Classification 00 Vacant Residential Mailing Address Property Value LENNAR HOMES LLC Ag Land $0 4600 W CYPRESS ST STE 200 .Land $24,020 TAMPA FL 33607-4099 Building $0 Physical Address Extra Features $0 6652 WAGON TRAIL STREET ZEPHYRHILLS, FL 33541 ]ust Value $24,020 Legal Description (First 4 Lines) Assessed (Non-School Amendment 1) $24,020 See Plat for this Subdivision Taxable Value $24,020 SILVERADO RANCH SUBDIVISION PHASES 6, 8 &9A PB 75 PG 075 BLOCK 6 LOT 4 ]urisdiction City:of Zephyrhills Land Detail (Card: 001 of 001) Line UseIDescriptionZoning _Units p !Price 1condition Value 1 _ ( 0100 SFR _-� MPUD ( 6,000.00 ;_ SF $4.00 1.00 $24,000 2 0100 ! SFR MPUD 50.00 SF $0.40 ( 1.00 $20 - Additional Land Information _ Acres 0.14 ITax Area 30SI FEMA __ Residential Code SLVRLPI Code Building Information - Use 00 - Unimproved (Card: 001 of 001) Unimproved Parcel 00 - Unimproved _ Extra Features (Card: 001 of 001) Line T,!Descriptionar—~ _ ,Unity- s --�� Value No Extra Features Sales History - See All 6 sales Previous Owner: DUNE FL LAND I SUB LLC Month/Year Book/Page _Type DOR Code Condition Amount 04/2018 9709 / 2014 Warranty Deed 05 Vacant Multi-Parcel Sale -- --- - ------ -- 05/2017 9535 / 0546 Certificate of Title 05 Vacant Multi-Parcel Sale 11/2016 �9462 / 0384 jMineral Rights or Royalty Transfer 05 Vacant Multi-Parcel Sale http://search.pascopa.com/parcel.aspx?parcel=2126050080006000040 4/23/2018 Single. Family .Dwelling Plan-Review Cominents 1 F.F.E. shall'be a minimum=of 8".above,the road.elevation and an engirieered.site plan. '2. Lots shall be graded.to comply with R401.3 of the F.B;C: 3. Compaction test required.if 24"'or mor&of fill dirt is brought in.at any one place: 4: 'Tie in. .urvey required before pounng concrete. 5. Driveways require a.R.O:W.use permit: All 4 sides of driveway thru the sidewalk shall_l aye expansion matenaL 6. All setbacks-shall be met... .7. All.property:mar e,rs shall be.uncovered"and marked at tim_ a"of first 'inspection: 8: :All A.D.A. requirements.shall be met.:'. 9.. No electric,plumbing,.mechanical,orfraining shall be covered without an.inspection"and approval first. . .. 10. All. Garages shall:comply.with:section R302.6.of the:F.B.C. (Fire Separation)'..' -.11. Appliances shall not:be installed in."a location where subject to mechanical darriage uriles5. protected.by approved barriers: M303 4 of the F.B.0 T2. Water. shall_comply with section`P607.3 of the"F.B.C: 13. Foundation supports for."A/C.units shall be raised at least 3'.' above finish grade., M1308.1 14. Return-air in all._bedroonis..F.B.C. ,MI620.4., 15. Smoke detectors are to be installed:in-accordance with R313:1 of theT.B.C. :. 16.:.All glazing requirements are.to be"in accordance with R308.4.of the F.B.C. 17. All means"of egress are to be in accordance with R3I Lof the F.B.C. . 18. "Green gypsum board" shall riot be used:as.a backer in showers or tubs:R702:4:2.F.B.C. 19. Combination-type AFCI breakers.are,required,at all,locations requiring.an AFCLtype breaker: 20. Carbon monoxide.alarms will.be required in new:construction that uses fossil-burning heating .or appliances or an attached garage:__They shall be,installed in accordance with the V.B.C. 21. All plumbing, mechanical,:and electrical shall separate from unit to.unit. This"includes all . underground plumbing and electric: 22. All 20l l.N.E.C: Codes.Will be enforced:. 23:Tamper= Resistant Receptacles in accord with 406.11 of the 2011 N.E:C 24An accordance.with the Land.Development:Code;lots.shall be sodded before final of leash 10 febt'around the.9tr 0ture: 25'A.copy of the energy"cacls shall be with permit at all'thnes. - 26.:Copy of Inal insulation'report shall be.yrovided with.permit before.fznaL F.F.E.=Finished Floor.Elevation F.B.C_-Florida Building Code 6t'.Edition R.O.W.-Right-of Way A.D.A.-Americans-with.Disabilities Act N.E.C.-National.Electric Code (2011): . When Buildings Talk.We Listen. FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Envelope Leakage Test Report Prescriptive and Performance Method Project Name: (p p Builder Name: L.P-n r yn p_S ! Street: (el&5R we'90n T-M J 5(-fe-f- Permit Office: City, State,Zip: Z-tp),y rh 1115 I=�� 33 Permit.Numb r: 0-0 Design Location: Jurisdiction: Envelope Leakage Test Results Single Point Test Data: ` HOUSE PRESSURE: U^� FLOW: �9 L Leakage Characteristics CFM(50): 1 LI ) Pass Fail ACH(50): 5,s R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zones 1 and 2 ...Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105(3)(f), (g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code officiate Testing shall be performed at any time after creation of all i penetrations of the building thermal envelope. 1-Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other Infiltration control measures; 2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended infiltration control measures; 3.Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if Installed at the time of the test,shall be turned off;and 6.Supply and return registers,If installed at the time of the test,shall be fully open - I hereby certify that the above envelope leakage Where required by the code official, testing shall be performance results demonstrate compliance with conducted by an approved third-party. A written report of Florida Energy Code requirements in accordance with the test results shall be signed by the third party section R402.4.1.2. conducting the test and provi to the code official. SIGNATURE: PRINTED NAME: i" 11ds`1 — IILDING Of1FI IAL: DATE: -7 01,201S _ DATE: g Testing was conducted In accordance with ANSI/RESNET/ICC 380 to meet the 2017 residential.energy code. ol Voli ��� N Jet Streame Ultra Blowing Wool Insulation Attic and Cayity Wall Card ever* we. 2,0 W 9 J Batts and.Blankets Equipment Required When'installed In accordance,with the manufacturer's It Is recommended!hat_a pneumatic blowing machine and,a corrugated hose with a minimum intemal corrugation,4 mlomum length recommendations,Knauf Insulation bags and blankets.will of 160'.Coils In the hose should not be less than 36"m diahneter.Acceptable material febid rate is 5-35 lbs/mlnule:Recommended feed provide the full R-value. rate is 15-25 lbs/minute. R4@ilue*- Minimum Thickness Thermal Rerfor.r0incle(Sidewall and.Attic Application) To obtain an The stated thermal resistance(R-value)Is provided bi-Ifistalling In accordinic6 with the'nianufadturier's Instructions.Failure-to Install the Insulation resistance Installed Insulation should re�uired'number of bag.E per 1000 square feet and exc6edind the maximui-h icluare deco(I I o6veralge per bagfas recommended by the label less than: vill result In lower Installed R-values.Field blending oi.this product with other loose fill insulations is not recommended by the manufacturer. (R.Value)of. 'net be R49 13.75" Cavity WallBag Net Weigh.t-Nomi I nal 32.tbs.,Minimum 31 lbs. R-38HD 10.25" 2- R-38 - 1 .00" R-Value* Bags per 1000 SF Maximum Net Minimum R-30HD 8.-25' To clotainrEln The number of bags Coverage per Bag Weight per SF hsulatlon per 1,000 square feet contents'of this' Themeight per square R-30 10.001, Cavity resistance of not area should not bag should not feet of Installed insulation R-26 -9.00" Framing Depth Of: Density be less Wan: -covairhoretho' should not be lase than: Rr22 6.50" 2"x 4" 3..50" R.1 5 1.8 lbs.ku.ft, 16A bags 61.0 sq.ft. 0.525 lbs-. R-21HD: 5;50" , 25.8 bags 2"x 6" 5.501, 23 18 ibsicu.ft 38.8 sq.ft. 0.825 lbs. R-19- 6.25` 1 1 .. - . - R�l 5H D 3,50" 2'x V, 7.25" 9-31, 1.8 lbs./cu.'ft. .34,0 bags sq.ft. 1.088 lbs. R-13 5.50" 2"x 10" 9.25" R=39 1.8 lb$dcu,ft. -43.4 bags 23.1 sq,ft. 1388 INS. R-11 3;50"- R'means resistance In heat flow,The higher the R--value,the greater the Insulating poker.Tq get the marked R--v!us,It is essential that.this insulation be Installed.properly, R78 2,50" R4in a 5.5'cavity.,Conforms toASTfA C665 and Federal Open-Attic Application Bag Net Weight-Nominal.32 Ibs.,Minimum 31 lbs. " Specification HH-1-52IF Minimum Bags/ Maximum Mi6im-u n Initial Settled Praming Adjustment 1,000 SF Coverage. Weight Installed -Thickness** To compensate for framing members;the,number of bags per Thb'numberof'bags/ Contents of this The weight/SF Thickness Contents of this- 1,000sq.4,of area to be insulated should be as shown below, R-Value* i,0.06'S,F of not area bag should not ofinstalled Installed Insulation bag should Bags/MSF Bags1MSF To obtain an Insulation should not bo.less cover insulation should not should not bo,loss not cover more -Joist 16"0.C. _24"AG. raslstanco'(R-Value)of lhain., more than; be less than ihirri 114afitle Dimensions Framing- Framing R-60 29.7 33.6 SF 952 lbs; 1§.750,; 1 Oti!i. 2x4 29.2 29.4 R49 23.5 42.5 SF 753 lbs. 16:375" 16.375" R-60 2x6 28.9 29.1 RA4 20.9 47.8 SF .670 tbs. 14;875" 14.875" 2X8 28.6 28;9 R738 17.8 56;2-SF .560 tbs. :1 j.,0-0-0-11 1,3.000" 2X4 23.0 23:2 FW.0 13.6' 73.3 SF .437 lbs. 10.375" 10.375" R49 2x6 22.7 22,9 - R-26 11.8 '85.0 Sr .377 tbs. 9.125- -9';126* 2X8 224 22.7 2x4 20.4 20,6� R-22 9.8 102.2 SF .313 tbs. 7.750" 7A0' R-44. 2x6 20.1 20.3 Rl19. 8.4 11.9.3-W .268 tbs. 6,750- 6.750- _2x8 19.8 20.1 R-1 3 5'7 175.3-SF .183-lbs. 4.750" 4150* 20 17.3 .17.4 ---a.7 -f R.11 l-0.8 152 tbs. 4.00W 4-000- R48, 2x6 17.0 17.21 eag Nel li�elght--NDdwl�12 tbs..l.'WM=it tbs. W 16.7 ITO co,mw arxd,WA%iwn daia vem-doewed using a wumxe if biq"Machdre In thydgm Wit 13'gax openn.9,2.0 psi ar ri p and 157 of YntEmallcoffra iid how This product co lo the e performance requireqienis oMSTM C 764.irnia 1,arii!canceled Federal Spec[N_Ii'on HH-1.1030B.Type 1,pass 8.R-va!u-s are MP'ned 6 30conlaace with 637a4C 518, 13.2 133 "R'means resistance 10 1pal gaa The higher Lhe R4".M gr6atertk inkialing P.-T.To gel ke mYked R-Vaf.ee,it is esSentiatIlhM M hSfia!iort be ird!aled popery.II you 6 Ifydun;o1f,set hst- R-36 .2x6 12.9 13.1 Pons and IcR=tern careVy.lrdhw�bns do not comWah M p4age.. ..Eased on Thint Pary2-years-tlnj so_ ped,ctodkedernarritcoara 20-yearpb 2x812.'6 12.9 unicknesst,"s Sam. v��A 20 11.3 11.4 Wu.fAaleillstireglstofedlrdem,.kolUrgsal.., R-26 2x6 11.0 11.2- Builder's Insulation Statement 2x8 10.8 11.0 Jet Stream Ultra has been installed in conformance with the included recommendations to provide a thermal resistance-of:.. 2x4 9.3. :9,5 - Ft-Value Thickness R-22 2X6 9A 9.3 Attic Area R- at lacfte-S 2x8 8.8 9. Sloped:Ceilings R- at Inches 2X4 7.9 8.1 wails R- at Inches Rmlt 2x6 7.7 7.9 W Floors(overan unheated crawl space) R- at Inches 2X8 7.4 7.7 2x4 5.3 5.4 Crawl Space Perimeter R- at inches- R-13 W 5.0 .5.2 Date Installed 2X8 4.8 50 Mown insulation has been installed in conformance with the above recommendatibm to,provide an Rmnlue 6f: 2A.. 4.3. 4:.41 bags of th!.s-insulatioh-to cover. L), -using W:L square feet of area k-1 1 2XI3 4.1 4:3 at a minimum thickness of fQ ZV inches. W x 3.8. OL UL enVro­1 GREENGUARD Gld- A 6-J-1 K,ouf I'vA­WAdiq hl".d,3 Ccm�*�-_ - - .,, fff Date- UL of in,] L. ke. UL Fnviionmenl GREENGUARD Home 801der(signature) C.,&.6-P-9-n- Ncd"we­QA w UL E-;,--. GUENGUARD t,dd,fn Company Date ­m'­i-,nd- ua. Fd The coverage Information on this Attic/Sidewall card-applies to the entire United States(including Minnesota). www.knaufinsuIatio`h.us Knauf Insulation,Inc. One Knauf Drive,Shelbyville,IN 46176 Tel:(600)8254434 ext.8300 FAX:(317)398.3675 r,),)n4 r V-4 Lennar Homes 6652 Wagon Trail St. 2,276 sq ft Column Es SQ. FEET PRICE MAIN OR LIVING: 2,276. $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 256,391.40 FEE SHEET $ 1,325.00 ADDRESS $ 40.00 DRIVEWAY $ 40.00 BUILDING: $ 1,431.50 ELECTRICAL: $ 298.13 PLUMBING: $ 198.75 MECHANICAL: $ 139.13 SUB-TOTAL $ 2,067.50 TOTAL $ 2,067.50 SEWER: WATER: IRRIGATION: $ - TOTAL: $ - WATER METER: IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 2,620.85 PARK IMPACT FEES $ 769.56 SIF'S: $ 7,128.00 100.0% $ 7,128.00 1.0% $ 71.28 TOTAL: $ 7,199.28 T I F'S: $ 3,632.00� 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 14,221.69 PASCO COUNTY, FLORIDA Permit No. 9L Date Permitted Builder Name/Owner Name e-Aytz, f-�,e-4LC Control# County Parcel No. SubDIv: c5i AddresslLocation 65-2 Claselficatlon/Type of Use 1" 4 TRANSPORTATION IMPACT FEE Rate, Sq.Ft Unit. ?-7 j; Exempt F1 Yes 17 No How Determined Impact Fee Amount Zone No. TAZ- SCHOOL IMPACT FEE Account (056) Single-Family Detached House Amount $ 2 ► — (057) Mobile Home (058) Other Residential 23) Collection Fee Exempt �Yes n No How Determined PARKS AND RECREATION FEE Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation Total Zone TOTAL AMOUNT Exempt n Yes F1 No How Determined LIBRARY FEE Land Account Land Credit Land Total Facility Account Facility Credit Facility Total Exempt []Yes ❑No How Determined Total Amount,— RESOURCE FEE ERU TOTAL AMOUNT Prepared By Checked By IV U NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE BEEN PAID AND RECISIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY Acknowledgement below does not Imply acceptance of concurrence,but simply receipt of copy of this form,placing the building permit owner on notice of this assessment and the conditions of payment for same. DATE RECEIVED BY RECEIPT NO. DATE BY 813-780-0020 City of Zephyrhills Permit Application. Fax-813-780-0021 Building Department Date Re'cehied Phone Contact for Permitting L 813 363 289:1 Owner's Name Lennar Homes,LLC Owner Phone Number r813.574,5700 Owner's Address 4600 W.Cypress St.Ste.200,Tampa,FL 33607 Owner Phone Number Fee Simple Titleholder Name I N/A Owner Phone Number Fee Simple Titleholder Address I N/A JOB ADDRESS 6652 Wagon Trail Street I LOT# 10040 SUBDIVISION Silverado Ranch Subdivision Ph 2,3,&4 PARCELID#105-26-21-0080-00600-0040 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTRR 0 ADD/ALT 0 SIGN 0 DEMOLISH INSTALL REPAIR PROPOSED USE SFR Q COMM OTHER TYPE OF CONSTRUCTION BLOCK Q FRAME STEEL DESCRIPTION OF WORK Single Family Residence Pool/Screen Enclosure/Fence BUILDING SIZE I 1J/R SF 2276 SQ FOOTAGE HEIGHT 1 Story ­ A ­ N1 1 . . .BUILDING 11 A131 VALUATION OF TOTAL CONSTRUCTION Fy/1 ELECTRICAL 1$ 1 AMP SERVICE PROGRESS-ENERGY Q W.R.E.C. �PLUMBING $ MECHANICAL 1$ VALUATION OF MECHANICAL INSTALLATION =GAS ROOFING Q SPECIALTY OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA EIYES Do BUILDER COMPANY Lennar Homes,LLC SIGNATURE 4 REGISTERED Y/ N FEE CURREN Address 14600 W.Cypress St.Ste.200,Tampa,FL 33607 License# [_EC1518166 ELECTRICIAN COMPANY Edmonson Electric, Inc. SIGNATURE REGISTERED Y1 N i FEE CURREN LILN__j 034 Skipper Road, Tampa, FL 33613 EC13005408 Address 5 License# F PLUMBER COMPANY Bayonet Plumbing, Heating &AC, Inc SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address P.O. Box 5308, Bayonet, FL 34674-5308 License# I CFC042998 MECHANICAL COMPANY Bayonet Plumbing, Heating &AC, Inc SIGNATURE REGISTERED. I Y/ N J FEE CURREN I Y/N I Address I-P.O. Box 5308, Bayonet, OL 34674-5308 License# I CAC058062 OTHER COMPANY = SIGNATURE REGISTERED Y/ N FEE CURREN LILN Address 14211 Shoal Line Blvd,Spri g Hill, FL 34607 License# I CCCO57991 RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&I dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required.onsite,Construction Plans,Stormwater Plans w/Silt Fence Installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Directions:- - - - - - - - - - - - - - - - - - Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement Is required. (A/C upgrades over$7500) Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter If on public roadways..needs ROW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have.the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If.you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees-and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07'and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner" prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. US Environmental Protection Agency-Asbestos abatement. Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone W" unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air.conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90) consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TP OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. FLORIDA JURAT(F.S. 117.03) OWNER OR AGENT CONTRACTOR Subscribed and sworn to(or affirmed)betorar me his Subscribed and sworn to(or g0ir ed)before me this ou-,ran-1 o by Paul Sweeney30-Jan-18 by Paul Sween Who is/are personally known to me or Who is/are personalIV known to rhe or hasihave pfedueed- _--asMentification. as identification. Notary Public Notary Public Commission No. FF98537 Commission No. FF98537 Elissa M.Holleran Elissa M.Holleran Name of Notary tvoed,printed y�o+r�)shtalgmi)ed Name of Notary typed,printed or stamped _ep h J p e eeg py� '•1 5�'Ik'W9MPIN�CIfl NYIi - d•' BNiII�I Wn@ITJI9.,5�I� . �a I�R 'anu�,�ppl�4laT' s1'CirWWbnr#lip nwor �I , @lh��'A11N'f7�rt481,9i�AHdO1�,71$tTNU � � 9��1�'�NT.�ra�o�419A�11�1118�'RfII _ 05-26-21-0080-00600-0040 j Pasco County Property Appraiser Page 1 of 1 Data Current as Of: Weekly Archive-Saturday, April 21, 2018 Parcel ID 05-26-21-0080-00600-0040 (Card: 001 of 001) Classification 00:- Vacant Residential .Mailing Address Property Value LENNAR HOMES LLC =Ag Land $0 4600 W CYPRESS ST STE 200 Land $24,020 TAMPA FL 33607-4099 Building $0 Physical Address Extra Features $0 6652 WAGON TRAIL STREET ZEPHYRHILLS, FL 33541 Just Value $24,020 Legal Description (First 4 Lines) Assessed (Non-School Amendment 1) $24,020 See Plat for this Subdivision Taxable Value $24,020 SILVERADO RANCH SUBDIVISION PHASES 6, 8 &9A PB 75 PG 075 BLOCK 6 LOT 4 Jurisdiction City of Zephyrhills Land Detail (Card: 001 of 001) _ Line _-'Use Descriptio_rnZoning Units Type Price 'Condition Ualue _ I r --- - 1 0100 -j SFR J MPUD 1 6,000_00� - SF_ -L- $4_00 1.00 ; $ 042 00 2 0100 SFR j MPUD T 50.00 SF $0.40 j 1.00 $20 _ Additional Land Information _ Acres 0.14 ( ' A 1 Tax Area 30SI I FEM f Residential Code SLVRLPI - I j Code I Building Information - Use 00 - Unimproved (Card: 001 of 001) Unimproved Parcel 00 - Unimproved Extra Features (Card: 001 of 001) - --- ------ -------_ _--� -- ----- —....� -,4-_......I._.._..----- - Line _ lDescription __—Year _ -T Units 'Value _ No Extra Features Sales History - See All 6 sales Previous Owner: DUNE FL LAND I SUB LLC - arr6o.o_k ._Pa_ efTYpeMonth Ye _ ODOR Code ConditionlAmount 04/2018 19709 / 2014 j Warranty Deed 05 ( Vacant Multi-Parcel Sale -------- ---- _05 i_ i9535 / 0546 Certificate of Title 05 Vacant -Multi-Parcel Sale 11/2016 19462 / 0384 'Mineral Rights or Royalty Transfer 05 f Vacant Multi-Parcel Sale http://search.pascopa.com/parcel.aspx?parcel=2126050080006000040 4/23/2018 SKETCH ONLY,` . SEC. 05—, TWP.--L6—S, RNG._.Z_lE. NOT A BOUNDARY SURVEY-PLOT PLAN BEARING BASIS: LOT 4, BLOCK 6 -35-32- E SILVERADO RANCH SUBDIVISION PHASES 6, ,.8. & 9A EAST BOUNDARY OF SUBJECT PLAT BEING N 02 PASCO COUNTY, FLORIDA. THIS SURVEY IS SUBJECT TO ANY FACTS THAT N MAY BE DISCLOSED BY A FULL AND ACCURATE PRELIMINARY DRAWING* ON LOT AREA CALCULATIONS TITLE SEARCH. ALSO SUBJECT TO SETBACKS, THIS PLAN IS FOR PERMITTING PURPOSES LOT ­�_6-0-5-0-00 SQ. FT. EASEMENTS AND RESTRICTIONS OF RECORD, ONLY, NOT FOR CONSTRUCTION. VERIFY LIVING AREA 7_1838 SQ.-FT: _0 UNDERGROUND FOOTER, STEM WALL, AND ALL DIMENSIONS BEFORE ANY CONSTRUCTION. ENTRY = 32---SQ. FT. UNDERGROUND UTILITIES ARE NOT LOCATED OR GARAGE = 4061—SQ. FT. SHOWN. LEGEND: COVERED LANAI =__.R/_L_SQ. FT. PROPOSED DRAINAGE FLOW PATIO =_23SQ. FT. DO NOT SCALE THIS PRINT. DIMENSIONS AND (00.00) = PROPOSED GRADE CONC. DRIVE = ;L3_ < 9LSQ. FT. NOTES TAKE PREFERENCE. E-00.00 = EXISTING GRADE A/C & CONC PAD = 18 SQ. FT. 0 PRIVATE SIDEWALK =__Z2_SQ- FL DESCRIPTION NOT CONTAINING PLAT BOOK AND IMPERVIOUS =45 PAGE INDICATES THAT PLAT IS IN t NOTES: = 272B SQ. FT, PRELIMINARY STAGE AND IS SUBJECT TO LOT GRADING TYPE = 8 SOD = 3322—sQ. FT, CHANGE AND/OR REVISION. PROPOSED PAD ELEVATION = 116.1' FRONT SETBACK = 20' OFF LOT AREA CALCULATIONS CERTAIN DATA SHOWN HEREON BASED ON SIDE SETBACK = 7.5' RIGHT OF WAY FT. ENGINEERING PLANS PROVIDED BY CLIENT. REAR SETBACK = 15' DRIVE APRON = 2.33 SQ. FT. 10' UTILITY EASEMENT PUBLIC SIDEWALK = 275 SQ. FT. SOD = 482L—SQ. FT. TOTALS AREA = 7040.9-0-SQ. FT. DRIVEWAY = fi72 SQ. FT. SIDEWALK FT. SOD = 38 L0_4SQ. FT. rpc(p) LOT 3 BLOCK 6 r0 Ld t� LOT 2 Lli ... . S 87-24'28" E 1.00' �.. °yoA BLOCK 6 ryo V) ihio' .............. 0 ,a 59'-4" I 30.17' 0 < Q L'i ID C ry 0-'C U)zy'z 0z14 < a- co L < In 9 7' 0• (N z 0 00 (D ....... ....... 12 — U) < 0 N 87' 4'28" W 110.00, O} LOT 5 TRACT A BLOCK 6 DRAINAGE AREA a) cc a_ PROPOSED: z x LOWEST FLOOR ELEVATIONS: LIVING AREA: 116.80' DESCRIPTION: GARAGE AREA:ELEVATIONS REFERENCED TO LOT 4 BLOCK 6, MAP OR PLAT ENTITLED "SILVERADO RANCH SUBDIVISION PHASES NORTH AMERICAN VERTICAL 'J' 0) 6, 8 9A", AS RECORDED IN PLAT BOOK 075, PAGES 075 THROUGH 080, OF THE DATUM OF 1988, MEAN SEA PUBLIC RECORDS OF PASCO COUNTY, FLORIDA, LEVEL= 00.00 FT. O Ca, APPARENT PPARENT FLOOD HAZARD ZONE: 'Y' COMMUNITY PANEL NO. 120230 0455 D EFFECTIVE DATE: 09/30/1992 (o D LOT (C)__ C LCUL (C)= CALCULATED DATA. (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, %= CENTERLINE, A/C= AIR CONDITIONER, B/C= BACK OF CURB, C/S= CONCRETE SLAB, CH= CHORD, CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= COVERED, E/P= EDGE OF PAVEMENT, ESM T= EASEMENT, F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE, FIR= FOUND IRON ROD, FN&D= FOUND NAIL & DISK, FPP= FOUND PINCHED PIPE. LFE= LOWEST FLOOR ELEVATION, MAS.= MASONRY, OR= OFFICIAL RECORD BOOK. PB= PLAT BOOK, PCP= PERMANENT-CONTROL POINT, PRM= PERMANENT z kjREFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2- IRON ROD & CAP No. 4493, SN&D= SET TEMPORARY BENCHMARK, U/P= UTILITY POLE, W/F-- WOOD FENCE, (R) = RADIAL Drawn By. Square Feet: �'6050. LENNAR HOMES JOHN R.BEACH&ASSOCIATES,INC. SMS x - SURVEYORS AND MAPPERS Checked By. 911 WEST ST. PETERSBURG DRIVE JRB ONE OLDSMAR, FLORIDA 34677 WAY (813) 854-1276 FAX (813) 855-8370 Scale: 1"=30' 0.5; NOT VALID WITHOUT THE SIGNATURE AND 1Date: PLOT PLAN 1/31/18 ACS zv '6 THE ORIGINAL RAISED SEAL OF A FLORIDA JO BEACH- D)kTE LICENSED SURVEYOR AND MAPPER ORIDA G. LAND-SURVEYOR No.,;2984 - LA3#4493 Revisions: 2 u wyl F=124.10 LOT 46 7"1 ti 4 PAD=123' X17.1,PT RT' TYPE.A F,F 00 FF-_122.20, 45 LOT 4,4 124 PAD=122.2 PAO= 5 15 TYPE A PER RI ANO D YPE jMTY ' iRAJNAGf�"EAS E 11 11 x 121.87 .5.34 N% /I x 123.83 x 1,'23.2 x 123.,aa ff x 124.6 45 xi 9.60 E 36 0 FF=1 5,9.20 4=-1 10.26 LqT.'41 LOT #2 = PAD=il'7.5PA0117.5 8.9 /TYPE A 'JiVE A 8.0 LOT 4 C14 PAD=l 18,2 PE D L. c SOAP TYPE,A T Ne F 120-30 LOT 39,PAD=l tit TYPE' Iv ;lg!!......... d1l 117 17 30 • 7 4q 7' 0 FF=1�0.30 LOT 38 0 P AD:5c 119.6 FF117.6ALOT 3 U) TYPE A PAD=1 16,0 C: F 0 N 4so TYPE .8 P, 0. vo I FF71 18.7 5. 6 LOT 37- ePAD-Il �1,PCE 0 T 00. it 4� E A to NO, % le lim,%low I co I Xii�.43 0 PF=l 16.30 FF=1-15.90 LOT 36 J. ly ee PAD=115.6 LOT __e TYPE A PAD=I, 8 5?I A TYPE Av(ll'o 3 v 134 v 15.30 40T 35 F=l 14 80f C)o PAD=114.6 , LOT TYPE A XJV4.11 JN. PAD=l 114-1`. Typgt 8 r FF 1 4.40 W C 9 P I FF ;113.0 M LOT 7 C U PE pAD=I13.2 e fo TYPE 0 C: in =jei3.6O FF= co 5" C14 �OT 33 F=1 13.10 P AD= lb 112.9 LOT 8 TYPE A pAD=l 12.4 tt TYPE Lr) 4i PASCO COUNTY, FLORIDA Permit No. (fGt7U Date Permitted Builder Name/Owner Name e A-W-4- Control County Parcel No. �J-2 -Z(--15 0�(��Od--I?6` p SubDiv: C51 Address/Location 2 ' Classification/Type of Use ! t TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: �t � Exempt ❑Yes ❑ No How Determined Impact Fee Amount Zone No. rTAZ: SCHOOL IMPACT FEE --� / Account (056) Single-Family Detached House Amount $ . �rl Z (057) Mobile Home " (068) Other Residential 123) Collection Fee Exempt [ Yes ❑ No How Determined PARKS AND,RECREATION FEE Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation Total Zone TOTAL AMOUNT $ -7 6566 Exempt ❑Yes ❑ No How Determined LIBRARY FEE Land Account Land Credit Land Total Facility Account Facility Credit Facility Total Exempt ❑ Yes ❑ No How Determined Total Amount, RESOURCE FEE ERU TOTAL AMOUNT Prepared By Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE of PASCO COUNTY Acknowledgement below does not Imply acceptance of concurrence,but simply receipt of a copy of this form,placing the building permit owner on notice of this assessment and the conditions of payment for same. DATE RECEIVED BY RECEIPT NO. DATE BY FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 1791A1 sf ADS Builder Name: Lennar Homes Street: 6652 Wagon Trail Street Permit Office: City ff Zephyrhills City,State,Zip: Zephyrhills,FL, Permit Number: Owner. Lennar Homes ,jurisdiction: 61 600 Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1572.7 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1241.30 ft2 b.Frame-Wood,Adjacent R=11.0 331.33 ft 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (1817.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1817.00 ft2 6. Conditioned floor area above grade(ft2) 1817 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(143.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 363.4 a. U-Factor: Dbl, U=0.54 87.00 ft2 SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.56 33.33 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 30.0 SEER:15.00 c. U-Factor: Dbl,U=0.56 23.00 ft2 SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 26.0 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 1.233 ft. Area Weighted Average SHGC: 0.308 14.Hot water systems 8. Floor Types (1817.0 sqft.) Insulation Area a.Electric Cap:40 gallons EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1817.00 ft2 b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.079 Total Proposed Modified Loads: 58.07 PASS Total Baseline Loads: 58.15 hereby certify that the plans and specifications covered by Review,of the plans and a: Y1E S`this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance �+ �aVe /J with the Florida Energy Code. ' +rrrr' '%`-= �.••;:5 �, O `, PREPARED BY: � Before construction is completed94 DATE: this building will be inspected for lyl : compliance with Section 553.908 I herebycertify that this building,as designed, is in compliance Florida Statutes. .� fY 9, 9 P with the Florida Energy Code CHEcKEa FEB 2018 OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: 4?'Af- - Compliance requires certification by the air handle unit manufacturer that the air handler enclosure qualifies as certified factory�sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.030 Qn for whole house. 2/1/2018 7:00 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 4 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 1791A1 sf ADS Builder Name: Lennar Homes Street: 6652 Wagon Trail Street Permit Office: City of Zephyrhills City,State,Zip: Zephyrhills,FL, Permit Number: Owner. Lennar Homes Jurisdiction: 611600 Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1572.7 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1241.30 ft2 b.Frame-Wood,Adjacent R=11.0 331.33 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 10.Ceiling Types (1817.0 sqft.) Insulation Area 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1817.00 ft2 6. Conditioned floor area above grade(ft2) 1817 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(143.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 363.4 a. U-Factor: Dbl,U=0.54 87.00 ft2 SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.56 33.33 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 30.0 SEER:15.00 c. U-Factor: Dbl,U=0.56 23.00 ft2 SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 26.0 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 1.233 ft. Area Weighted Average SHGC: 0.308 14.Hot water systems 8. Floor Types (1817.0 sqft.) Insulation Area a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 1817.00 ft2 b. Conservation features EF:0.950 b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.079 Total Proposed Modified Loads: 58.07 PASS Total Baseline Loads: 58.15 hereby certify that the plans and specifications covered by Review of the plans and ;a 'THE'STA� this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code.Dave PREPARED BY: /,/rich Before construction is completed DATE: this buildingwill be inspected for P t771 compliance with Section 553.908 * �_• herebycertify that this building,as designed, is in compliance Florida Statutes. N fY 9� 9 P -.,: . �, with the Florida Energy Code. OWNER/AGENT: BUILDING OF ICIAL: DATE: DATE: 7-- i - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house. 2/1/2018 7:00 AM EnergyGaugeO USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 4 r FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 1791A1 sf ADS Builder Name: Lennar Homes Street: 6652 Wagon Trail Street Permit office: City of Zephyrhills City,State,Zip: Zephyrhills,FL, Permit Number: Owner. Lennar Homes Jurisdiction: 611600 Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1572.7 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1241.30 ftz b.Frame-Wood,Adjacent R=11.0 331.33 ftz 3. Number of units,if multiple family 1 c.N/A R= ftz 4. Number of Bedrooms 4 d.N/A R= ftz 5. Is this a worst case? Yes 10.Ceiling Types (1817.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1817.00 ftz 6. Conditioned floor area above grade(ftz) 1817 b.N/A R= ft2 Conditioned floor area below grade(ftz) 0 c.N/A R= ftz 11.Ducts R ftz 7. Windows(143.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 363.4 a. U-Factor: Dbl,U=0.54 87.00 ftz SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.56 33.33 ftz 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 30.0 SEER:15.00 c. U-Factor: Dbl,U=0.56 23.00 ftz SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ftz a.Electric Heat Pump 26.0 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 1.233 ft. Area Weighted Average SHGC: 0.308 14.Hot water systems 8. Floor Types (1817.0 sqft.) Insulation Area a.Electric Cap:40 gallons EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1817.00 ftz b. Conservation features b.N/A R= ftz None c.N/A R= ftz 15.Credits Pstat Glass/Floor Area: 0.079 Total Proposed Modified Loads: 58.07 PASS Total Baseline Loads: 58.15 I-hereby certify that the plans and specifications covered by Review of the plans and :TkXES , 1,. this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance �,/ /, with the Florida EnergyCode. �. lmr• ���' PREPARED BY: v Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 ,. I hereby certify that this building,as designed, is in compliance Florida Statutes. �( with the Florida Energy Code. a�`y -T OWNER/AGENT: BUILDING OFF IAI DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house. 2/1/2018 7:00 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 4 r FORM R405-2017 PROJECT Title: 1791A1 sf ADS Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 1817 Lot# Owner Name: Lennar Homes Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: Lennar Homes Rotate Angle: 45 Street: Permit Office: Cross Ventilation: County: Pasco Jurisdiction: Whole House Fan: City,State,Zip: Zephyrhills, Family Type: Single-family FL, New/Existing: New(From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Tampa FL_TAMPA_INTERNATI 39 91 70 75 645.5 54 Medium BLOCKS Number Name Area Volume 1 Block1 1817 14536 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1817 14536 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio Main 155 ft 0 1817 ft2 0.3 0 0.7 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1968 ft2 0 ft2 Medium 0.85 No 0.9 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 1817 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) Main 30 Blown 1817 ft2 0.11 Wood 2/1/2018 7:00 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 4 FORM R405-2017 WALLS Adjacent Space Cav Width Height Sheathing Framing Solar Below Qmt Tn Wall Type ity 1 N=>NE Exterior Concrete Block-Int Insul Main 4.0999 19 6 8 156.0 ft2 0 0.600000 0 2 N=>NE Garage Frame-Wood Main 11 20 8 8 165.3 ft2 0 0.01 0 3 W=>NW Garage Frame-Wood Main 11 20 9 8 166.0 ft2 0 0.01 0 4 E=>SE Exterior Concrete Block-Int Insul Main 4.0999 58 8 464.0 ft2 0 0.600000 0 5 S=>SW Exterior Concrete Block-Int Insul Main 4.0999 34 8 272.0 ft2 0 0.600000 0 6 W=>NW Exterior Concrete Block-Int Insul Main 4.0999 37 8 8 301.3 ft2 0 0.600000 0 7 S=>SW Exterior Concrete Block-Int Insul Main 4.0999 6 8 48.0 ft2 0 0.600000 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N=>NE Insulated Main None .2 3 6 8 20 ft2 2 N=>NE Wood Main None .4 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered orientation(=>)changed to Worst Case. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N=>NE 1 Metal Low-E Double Yes 0.56 0.28 N 23.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds None 2 E=>SE 4 Metal Low-E Double Yes 0.54 0.31 N 32.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds None 3 S=>SW 5 Metal Low-E Double Yes 0.54 0.31 N 32.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds None 4 S=>SW 7 Metal Low-E Double Yes 0.56 0.32 N 33.3 ft2 2 ft 0 in 0 ft 4 in Drapes/blinds None 5 W=>NW 6 Metal Low-E Double Yes 0.54 0.31 N 23.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 427 ft2 427 ft2 42 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1695.9 93.1 175.09 .2669 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ None HSPF:8.5 26 kBtu/hr 1 sys#1 2/1/2018 7:00 AM EnergyGaugeO USA-FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 4 FORM R405-2017 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 30 kBtu/hr 900 cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 40 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS —Supply— —Return— Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 363.4 ft Main 90.85 ft Proposed Qn Main —cfm 54.5 cfrn 0.03 0.60 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Cooling [ ]Jan Feb Mar Apr I i May ri Jun Jul ri Augri Se Oct Nov Dec Heatin [X]Jan H Feb ki Mar Apr May Jun ri Jul Au Sep f i Oct X Nov Dec. Ventin [ ]Jan Feb Mar [X]Apr May Jun Jul Aug Se [X Oct. X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 2/1/2018 7:00 AM EnergyGauge@ USA-FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 4 t 5 FORM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerformance Index, the more efficient the home. Zephyrhills, FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1241.30 ftZ b.Frame-Wood,Adjacent R=11.0 331.33 ftz 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ftZ 10.Ceiling Types Insulation Area 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1817.00 ftZ 6. Conditioned floor area(ftZ) 1817 b.N/A R= ftZ 7. Windows" Description Area c.N/A R= ftZ a. U-Factor: Dbl,U=0.54 87.00 ftZ 11.Ducts R ftZ a.Sup:Attic,Ret:Main,AH:Main 6 363.4 SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.56 33.33 ftZ SHGC: SHGC=0.32 12.Cooling systems kBtu/hr Efficiency c. U-Factor: Dbl,U=0.56 23.00 ftZ a.Central Unit 30.0 SEER:15.00 SHGC: SHGC=0.28 d. U-Factor: N/A ftZ 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 26.0 HSPF:8.50 Area Weighted Average Overhang Depth: 1.233 ft. Area Weighted Average SHGC: 0.308 8. Floor Types Insulation Area 14.Hot water systems Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 1817.00 ftZ a.Electric EF:0.95 b.N/A R= ftZ c.N/A R= ftZ b. Conservation features None 15.Credits Pstat certify that this home has complied with the Florida Energy Efficiency Code for Building .g�9r Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completedj,, based on installed Code compliant features. Builder Signature: Date: �. 9 02/01/18 Address of New Hom 6652 Wa on Trail Street City/FL Zip: Ze h rhills,FL 33541'. � F Y goo *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 2/1/2018 7:02 AM EnergyGauge®USA-FlaRes2017 -Section R405.4.1 Compliant Software Page 1 of 1 Building Analysis Job: 1791A1 sf ADS g Y Date: 2/1/2018 Entire House By: Dave Bayonet Plumbing Heating and Air Project Information For: Lennar Homes Design C• • • Location: Indoor: Heating Cooling Tampa International AP, FL, US Indoor temperature(OF) 70 75 Elevation: 10 ft Design TD (OF) 39 16 Latitude: 28°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 34.7 54.7 Dry bulb(OF) 31 91 Infiltration: Daily range(OF) - 14 ( L ) Method Simplified Wet bulb (OF) - 77 Construction quality Semi-tight Wind speed(mph) 15.0 7.5 Fireplaces 0 Component Btuh/ftz Btuh % of load Walls 5.6 6529 25.4 gas Glazing 30.2 4772 18.6 wail Doors 23.5 466 1.8 nfiltrafion Ceilings 1.3 2271 8.8 Floors 3.4 6125 23.9 Infiltration 2.2 2887 11.2 Ducts 2616 10.2 Piping 0 0 Glazing Floors Humidification 0 0 Ventilation 0 0 other Ceilings Adjustments 0 Total 25667 100.0 • • Component Btuh/ft2 Btuh % of load Walls 2.8 3248 14.4 Walls Glazing 48.8 7718 34.2 ntemal Gains Doors 18.4 365 1.6 Ceilings 1.7 3140 13.9 Floors 0' 0 0 Infiltration 0.5 647 2.9 Ducts Ducts 2982 13.2 Ventilation 0 0 Internal gains 4498 19.9 Glazing Blower 0 0 Infiltration Adjustments 0 Ceilings Total 22596 100.0 Other Latent Cooling Load= 3525 Btuh Overall U-value= 0.104 Btuh/ft2-°F Data entries checked. - 1- wrightsoft® 2018-Feb-01 06:48:45 ACCA Right-Suite®Universal 2017 17.0.23 RSU05714 Page 1 ...CBA27UHE AH's\1791A sf ADS template 2.5ton.rup Calc=MJS Front Door faces: W r y Project Summary Job: 1791A1 sf ADS Date: 211/2018 Entire House By: Dave Bayonet Plumbing Heating and Air Project I • • For: Lennar Homes Notes: 40'ADS-2017 Design Information Weather: Tampa International AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 31 OF Outside db 91 OF Inside db 70 OF Inside db 75 OF Design TD 39 OF Design TD 16 OF Daily range L Relative humidity 50 % Moisture difference 55 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 23051 Btuh Structure 19615 Btuh Ducts 2616 Btuh Ducts 2982 Btuh Central vent(0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 25667 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 22596 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 2991 Btuh Ducts 534 Btuh Central vent(0 cfm) 0 Btuh Heatingg Coolingg (none) Area(ft2) 1817, 1817 Equipment latent load 3525 Btuh Volume(ft') 15459 15459 Air changes/hour 0.26 0.14 Equipment Total Load (Sen+Lat) 26122 Btuh Equiv.AVF(cfm) 67 36 Req. total capacity at 0.85 SHR 2.2 ton Heating Equipment Summary Cooling Equipment Summary Make Lennox Make Lennox Trade 14HPX SERIES Trade 14HPX SERIES Model 14HPX-030-230-21 Cond 14HPX-030-230-21 AHRI ref 10258600 Coil CBA27UHE-030-230`++TDR AHRI ref 10258600 Efficiency 8.5 HSPF Efficiency 13.0 EER, 15 SEER Heating input Sensible cooling 25500 Btuh Heating output 26400 Btuh @ 47°F Latent cooling 4500 Btuh Temperature rise 24 OF Total cooling 30000 Btuh Actual air flow 1000 cfm Actual air flow 1000 cfm Air flow factor 0.039 cfm/Btuh Air flow factor 0.044 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.87 Capacity balance point= 31 OF Backup: n/a n/a Input= 0 kW, Output= 0 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Wrl htsoft- 2018-Feb-0106:48:45 .►� g Right-Suite®Universal 2017 17.0.23 RSU05714 Page 1 ��` ...CBA27UHE AH's\1791A sf ADS template 2.5ton.rup Calc=MJ8 Front Door faces: W r e Manual S Compliance Report Job: 1791A1 sf ADS p p Date: 2/1/2018 Entire House By: Dave Bayonet Plumbing Heating and-Air Project I • • For: Lennar Homes Cooling Equipment Design Conditions Outdoor design DB: 91.30F Sensible gain: 22596 Btuh Entering coil DB: 75.7°F Outdoor design WB: 77.3°F Latent gain: 3525 Btuh Entering coil WB: 62.8°F Indoor design DB: 75.0°F Total gain: 26122 Btuh Indoor RH: 50% Estimated airflow: 1000 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Lennox Model: 14HPX-030-230-21+CBA27UHE-030-230"++TDR Actual airflow: 1000 cfm Sensible capacity: 25500 Btuh 113% of load Latent capacity: 4500 Btuh 128% of load Total capacity: 30000 Btuh 115% of load SHR: 85% Heating Equipment Design Conditions 11 - Outdoor design DB: 30.8°F Heat loss: 25667 Btuh Entering coil DB: 69.6°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Lennox Model: 14HPX-030-230-21+CBA27UHE-030-230*++TDR Actual airflow: 1000 cfm Output capacity: 26000 Btuh 101% of load Capacity balance: 31 of Supplemental heat required: 0 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: n/a Model: n/a+n/a Actual airflow: 1000 cfm Output capacity: 0 kW 0% of load Temp. rise: 0 °F Meets are all requirements of ACCA Manual S. -ELL wri htsoft° 2018-Feb-0106:48:45 I. 9 Right-Sufte®Universal 2017 17.0.23 RSU05714 Page 1 14C(:�k ...CBA27UHE AH's\1791A sf ADS template 2.5ton.rup Calc=MJB Front Door faces: W 2018072022 • kcpt:1952755 Rec: DS: 0.00 IT: 0.00 04/30/2018 K. A. , DptY Clerk pRULA S.0'NEI hP DL DL PRSCO CLERKof C1fIPTROLLER 04/30/2018 1ON:49ann PG Of I OR BK 97 i 64 Permit No. Parcel Ib No 05-26-21-0080-00600-0040 NOTICE OF COMMENCEMENT State of Florida County of Pasco THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 713,Florida Statutes, the following information is provided in this Notice of Commencement: 1. Description of Property: Legal SILVERADO RANCH SUBDIVISION PHASES 6.8&9A PB 75 PG 75 BLOCK 06 LOT 04 Street Address: 6652 Wagon Trail Street Zephryhills FL 33541 2. General Description of Improvement Single Family Residence/Pool/.Screen Enclosure/Fence 3. Owner Information: Lennar Homes, L.L.C. Name 4600 W Cypress St, Ste 200 Tampa FL. 33607 Address City State Interest in Property: Name of Fee Simple Titleholder: N/A (If other than owner) Address City State 4. Contractor: Lennar Homes, LLC Name 4600 W Cypress St, Ste 200 Tampa FL, 33607 Address City State Contractor's Telephone No.: 813.574.5700 5. Surety: N/A Name Address City State Amount of Bond: $ Telephone No.: 6. Lender: N/A Name Address i City State Lender's Telephone No.: 7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)(7),Florida Statutes: Lennar Homes, LLC Name 4600 W Cypress St, Ste 200 Tampa FL, 33607 Address City State Telephone Number of Designated Person: 813.574.5700 8. In addition to himself,the owner designates N/A of to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statutes. Telephone Number of Person or Entity Designated by Owner: 9. Expiration date of Notice of Commencement is one year from the date of recording unless a different date is specified: WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. STATE OF FLORIDA COUNTY OF PINELLAS � Signature of Owner or Owner's Authorized Officer/Director/Partner/Manager Vice President Signatory's Title/Office The foregoing instrument was acknowledged before me this 30 day of March i by Steve Robert Smith as Vice President (type of a rit , icer,trustee,attorney in fact)for Lennar Homes. LLC —(nam party o e of whom instrument was executed). Personally Known R OR P[oduoed]&ntification-El - Notary Sigfta Type of Identification Produced Name(Print) Elissa.Holleran i Verification pursuant to Section 92.525,Florida Statutes. Under penalties of perjury,I declare that I have read the foregoing and that the facts stated in it are true to the best of my knowledge and belief. ELISSAM.HOLLERAN' ;': Signature of Natural Person Signing Above 6mmleslon#FF88583f Ex'lm June 0,2020 wpdata/bcs/bcsforn R Bonded ThmTmy.Folnlauntnce100.3wyow STATE OF FLORIfi?�4,C®6JPlTY OF PASC® THIS IS TO CERTIFY THAT THE.FOREGOING IS A TRUE AND CORRECT COPY OF THE DOCUMENT ON FILE OR OF PUBLIC RECORD IN THIS OFFICE m W1T ESS MY HAND AND OFFICIAL SEAL THIS !n Cod we Trust _ DAY OF. z , ��� PA S.O'NEIL,CLER &COMPTROLLER 1d87 BY (::�k �� "Q � DEPUTY CLERK ����OF Ft-®���1� /�.� 1_lUP1UP City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: Date Received: ��Ll Site: 57— TA q— Pen-nit Type: 'sv Lo 2 1 Z7 P T(, T C. Approved w/no comments:❑ Approved w/the below comments: Denied w/the below comments: ❑ .I This comment sheet shall-be kept with the permit and/or plans. I Gli Kalvin §3kitzer— xaminer Date Contractor and/or Homeowner (Required when comments are present) 5335 - 8TH STREET (813)780-0020 CERTIFICATE OF OCCUPANCY Address: 6652 WAGON TRAIL ST Owner: LENNAR HOMES LLC ZEPHYRHILLS, FL. 4600 W CYPRESS ST STE 200 Subdiv: SILVERADO TAMPA FL 33607-4099 Parcel: 05-26-21-0080-00600-0040 Work Type: 101-NEW CONST/SFR Construction Type: NOT APPLICABLE ❑ Sprinklers Use Classification: NOT APPLICABLE Permit Number: 19600 Date: 6Z� 2018 U,i J'�o ISSUED EN BUILDI OFFICIAL : WATER MUST BE CHANGED OVER WITHIN 10 DAYS OF ISSUANCE GARBAGE DEPOSIT MUST BE APPLIED FOR PRIOR TO ISSUANCE