Loading...
HomeMy WebLinkAbout18-19601 CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 ,:19601 BUILDING PERMIT SINGLE FAMILY TIAL (PERMIT INFORMATION" ATION INFORMATION Permit#:19601 Issued: 5/01/2018 Address: 6A21 WAGON TRAIL ST Permit Type: NEW SINGLE FAMILY DWELLING PEPHYRHII LS, FL. Class of Work:- 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 256,391.40 Total Fees: 14,221.69 Subdivision: SILVERADO Amount Paid: 14,221.69 Date Paid: 5/01/2018 Parcel Number: 05-26-21-0080-00600-0340 CONTRACTOR INFORMATION I OWNER INFORMATION Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC Addr: 4600 W. CYPRESS ST STE 200 Address: 4600 W CYPRESS ST STE TAMPA, FL. 33607 TAMPA FL 33607-4099 Phone: (813)574-5743 Lic: Phone: 813-574-5700 Work Desc: CONSTRUCT SINGLE FAMILY 2,276 SQ FT APPLICATION FEES BUILDING FEE 1,431.49 ELEC RCA FEE 298.13 PLUMBING FEE 198.75 MECHANICAL FEE 139.13 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES SF l 769.56 SCHOOL IMPACT FEE NEW 7,128.00 SCHOOL-SFR NEW 1% 71.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32 P6 Inspections Required FO TER 2ND ROUGH PLUMB misc INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit,there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications and Must Accompany Application. All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. D� PP dA0 I C CTORS SIGNATURE PERMIT OFFIjFA PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER Jet-StreamO Ultra Blowing Wool Insulation NAU X Attic an;! Cavity Wall Cardam �eej Batts. - d Blabikets Equipment -'--d An qq 0 _Requited Men Installed In accordance With the.monufacturerr's, It k recorrimpnito that a pneumatic blowing machine and a cor�ugaled hose with a rnInirquT1A*iqberr!pI,corrpgation,a minlinuni'length re M co.rnm-endati6ris,knduf insulation baitts and blankets will -of 15VCok in'the hose should n61 be less than 36'In diarrfeIer.-�kcqqpIqbIe rhat6dal fe7ed rate is 5-.35 lb ute,Recommended.­ ieda s/Mln pro'vIdd the full R-Value; rate is 18725 lbskniiiiuti. 1144lue' Miffifflu'rh Thickness Thethial Performance(SidewBill and Attic App lication)' To obtain in 1ii6 itatiiid-ihirrnel resistance(k-466)is provided by installing in accordance with the'firiiWatturer'i Inkudi6ris.Failure to Irfst6ll the lnsu!qli'on resistance Installed Insulation should required number of bags per1,000.s*,q'u5re feet and exceed in Ind the*rnkirn I urn-square,feet-of coveraFge ftr b:�p.s recommended tl�the.label (R-Value)of: in.ot I be less I than: will resuhlri'lower installed lk-values:Field'blending of this product vith'tither loose fill insulations Is not rec6himepd'ed6ythqrnanufacIurer., R49 13.761 11 Bag-Nei Wdight,--Aq Irial 32 lbs;,Min; R-38HD 10.25' -Cav�fy a. m Minimum 31 ibs., R-38 12.00" kmV6Iue# Not BagsSF MaximumMaximumMinimum per.1006, UOHID - 8.25" To obtain an The number of bags CoVerqge'por Bag weighfoersi:; Indulat6n: piirl';00,0 square Met, conteiiii of,thli The weight por itin-re R-30 1 O.OV1 Cilvity roostance of not area-should bag should not feet of Installed insulation .9.007 Framing Depth of., Density 66 6--s-than:; cover r,Oie than: iiiiiiiiii6oibe less than:_ --------R*-22 6.50,." 2"x 47 3.501, R-11 5 1.8 IbsJcu.ft; 16.4 bags 6 I.Q tq,!t.. 0.525 lb$. R-21HD. 5.-50, 2".x 6": 6'.50" R-2- 1 1.8 lbs.-Icu.,I ft. 2.6.6 bags> 38-.8 sq.ft. 0.8-25lbs. R19 R 31 1;8 lbs./cu.ft: .34:0 bags sq,,k 1.08-:6-lbst R-15HD 3.50" zo, 7.25" R-1 3 3.50" Yx 10" 9.'25' R-39 1.8 lb§;16u.ft, 43.4 bags, • 1.388.1bs. _13-111 150' Wmeans resistance 16 fieviliom.the tk ei the R-value,the greater the InstIta.M lfog�fihe!na�q� -Val 9 PcOr. ue,a Is essential that 61s;tasiiiallon be Installed properly. R-8 --2.50! - ' "R-16iia5.5".cavity.0on-ormstoMkMand Federal 'Open Attic Application Bag Nbt_WeIght�NomIna i 32-lbs.,Minimum 31 lbs: Minimum Bags! Maxiffitimi Mifilf--U-- Initial Settled Framing Adj'bstment .- gs: .Minimum finstalled, To compensate for framing mernbers,4e number ofbags per 1,000 SF Coverage Weight Thkkness'k' 1,000 s -ft of area Ig-be insulated should be as showrf below. 11-Valve" The number of bags/ Contents at this The vialilitISF Joikkheps� conle-ints'of this q; IiOOO SF'of net 6 roa- 66' U stalled lnstalQ-1-dsul6liofl* bafg should q_sh0fd no of installed To obtain an Insulation s6ouid not be iess cover Insulation should no should nolbe less' Bags/M-SF hgs1MSF not cover more roslilariCd(R-vituo)of: than:-- -,orb than: be loss than Joist' 16"-0;C. 24"O.C.. than, -thad. R.W.10 Dlm6!iilort� FramingFraffilng R-60 29.7 _33;13SF g52'ibs;. 19.750" 19;75V 2x4 R49 23.5 42.5 SF ;753-lbs. _16,37,57-- 29'.2 29.4 .16,178" W.- 28.9 R;44 20.9 47.8.SF .070 lbs. 14'.815" 14.87Y' 28:6 213.9 R438 17.8 5.6.2 SF-- -.5691bs. 18.000.fl-- 13.000�, 2x4 210. 23,2 R-30 13.6. 73.3'Sl` .437 lbs, 10.375" '1 03TY; R49 24 22.7 '22.9 R-26 11.9 SF377 lbs 2x8__ 22.4-' -22:7 . ., 9.125" 9­1125'� 20.4 20,6 R'22- u 1022S17 -.313.1bs. 7,750" 7.750" R44 2k6'- 20.1 -20.3 R-'Ig. 8.4- 119.3 SF .269,lbs-. 6.750'! -6 759' W 19.8, :20.1 R 13 5.7 -ftlbF A 0 lbs. '4J50! 4.750" W. '117.3 17.4- - R 43,8 W. R41 4.7--t �1 0.8 SF AkOO" 4,000, A 7.2- easnMl w 47. 1 2X& %.7 17.0 EE PVO to J&2 0 h��zr the it R,30 _24 .12.9- 13.1-- sow M�Oy M a 0 not nce P2. a So SW 4�ad 5 V 0 Y P7 2d ia. 12.9 NskMssesam eaoclNeylnes 20 11.3' 11.4 R.-26 W 11,0 11.2, Builder!s Insulation Statement 2x8l 10H 11,0 Jet Stream Ultra'hats beenrlinSiBiled in conformance with fecommerfidetions to-providera'theninal resistance'df,. 2x4* 9.3 9.6 RIValud Thidhes s*-_ 1142 2x6, .9.1 3 Attic Area" R- at Inches W 8.8 Sl_boTd Ceilings 2x4 T9 8. At 1nbheg Walls, at Ihbhd R-19 2k6l-W 7.4 7.7 7:91 77 Floors(over an unheated cfaiWspke) R- at Inches ' -3 CraWl'S pace Perimeter-294:- -5. _5A. at Inches 111-113 --2x6'- 5.0 5:2 7 Date'Installed 2z8. 4.8 5.0 Bl6yn l4suldion has been installed InPonformafic.q.with*the above b re cornmVed Irions to provide an R-value of:,. A_ _43' R-_ 2x4' 4.4 using, e-A bags of this:in'suilation.to cover -feet of area FW 1. _2x6 .4.1 43 at a minimum thickness of 97 5- -inches,. square W 3.8 4i1 -Tnsu tion nlrado naly nn r- :7 (17)�6411 U1 Eftl,­M qqEENGUA1ID GoW­d,ls. cldr�pa_ny U1 1,6 fj;­kmiq.fi" UL GREENGUARD, HoniB Builder(signature) W..EE NWAW­J.A 1,Prod"u ern c"rtiFd It, C6mony Dale .i_:W. d gpqd�a F.Ka-I- Wo, The coverage Information on this Atilcisfidewall card applies to the entire United States(including Minnesota). vvwW.knau[fm_sulation.,us; Knauf-Insulation,Inc. 'One Knauf brine,8helb.01lej IN,46176 TO(800)8254.4M ext.4306 FAX:(3C7)'398-3675 J � V —�.— ---'- . ", ISuildinp;and t un.Si'uctiun tier-ices(ISCJ) �'.� ' PASCoUNTY FU pj,j)A�� - Blower Door Test Report Form Property Address: nh M: /� W CL C�'1V�1.ti_[Y-ilt�' J 6 I Testing Company.Name:SKYETEC Test Date: �O Tester rtaHASSEN KHEI.IFI - - T-tuUnP: WH66, c..wPt.__904-903-1076 -` Er;;a+:hkhelif@sk e"tec.com 402.4.1:2 Testing.Building envelope air tightness shall be demonstrated b}'Section 402.4.1-2 The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5.air changes j per hour. Testing shall be conducted with a blower door at a pressure of 0.2 inches W. (50 Pascals).As required by the Building Official,testing shall be,conduele d by an approved third party.A written report of the results of the test shall be signed-by the party conducing the lost(including Agency Dame)and provided to the Btrilding'OfBcial prior to Certificate of Occupancy issuance.Testing shall be performed at any time after creation of all scheduled penetrations of the building thermal-envelope- During testing:(check to verify condr7don met) i Werior windows and doors,fireplace and stove doors shall be closed,but notsealed,beyond the intended weather- stripping or other tD ft[Dampers including exhaust,intake,makeup air,backdra and Rue dampers shall Ire dosed,but not sealed beyond i �intended'infiltration ' n rior doors,if installed at the time of the test,-shall be open �VVVV rior doors for continuous ventilation systems and heat recovery ventilators shall be dosed and sealed �ating and cooling systems,if installed at the time of the test,shall be turned off Supply and return registers,if installed at the.time_of the test,shall be fully open I Vb Building,voluine(W) _ QM Airflow at 50 Pascal'(CFM) _ ACHso Air changes per hour at 50 Pascal: Qsox 60=Vb= j lb ACH5o(IOACHminimum) Pass Fail 0 0 Outside Air mechanically introduced to space(less than 3,0 ACH) I hereby certify that the above envelope leakage performance results demonstrate compliance _Mth Florida Energy Code requirements in accordance with Section R402.4 L2. 7 30. -�niR' Signature of Tester Date IPASCO COUNTY, FLOR40A Permit No. �JAW Date Permitted Builder Name/Owner Name l-t r L '�' '�'�'�" 41c,Control#- " .! i County Parcel No. /-2-J-2-f-.Oc'8o- 560(oco-0376 SubDiv: Z` AddressiLocation � Z t ClassilicationlType,of Use cat in, TRANSPORTATION IMPACT FEE Rate: Sq.FtUnit: 24276 Exempt n Yes ❑No How Determined Impact Pee Amount $34 ITO Zone No. TAZ: SCHOOL IMPACT FEE Account (056) Single-Famlty D_atached House Amount $ ` A 12-6• (057) Mobile Home (058) Other Residential 23) Collection Fee Exempt [(]Yes ❑ No How Determined C PARKS AND RECREATION FEE Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation Total Zone TOTAL AMOUNT $ 7 6?6,6 Exempt Yes []No Haw Determined LIBRARY FEE Land Account Land Credit Land Total Facility Account Facility Credit Facility Total Exempt ❑Yes ❑No How Determined Total Amourd*� RESOURCE FEE ERU TOTAL AMOUNT Prepared By z _ Chocked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY Acknowledgement below does not imply acceptance of concurrence,but simply receipt of•a copy of this form,placing the bullding permit owner on notice of this assessment and the conditions of payment for same. DATE RECEIVED BY RECEIPT NO. DATE BY 2018072025 = Rcpt:1952755 Rec: 10.00 — DS: 0.00 IT: 0.00 04/30/2018 K. A. , DptY Clerk PAULR S.0'NEIL,Ph.D.PRSCO CLERK�f C1MPTROLLEk 04 OR BK019716 PG 206 Permit No. Parcel ID No 05-26-21-0080-00600-0340. NOTICE OF COMMENCEMENT State of Florida County of Pasco THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 713,Florida Statutes, the following information is provided in this Notice of Commencement: 1. Description of Property: Legal SILVERADO RANCH SUBDIVISION PHASES 6,8&9A PB 75 PG 75 BLOCK 06 LOT 34 Street Address: 6521 Wagon Trail Street Zephryhills FL 33541 2. General Description of Improvement Single Family Residence/Pool/Screen Enclosure/Fence 1 Owner Information: Lennar Homes, L.L.C. Name 4600 W Cypress St. Ste 200 Tampa FL. 33607 Address City State Interest in Property: Name of Fee Simple Titleholder: N/A (If other than owner) Address City State 4. Contractor: Lennar Homes, LLC Name 4600 W Cypress St, Ste 200 Tampa FL, 33607 Address City State Contractor's Telephone No.: 813.574.5700 5. Surety: N/A Name Address City State Amount of Bond: $ Telephone No.: 6. Lender: N/A Name Address City State Lender's Telephone No.: 7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)(7),Florida Statutes: Lennar Homes, LLC Name 4600 W Cypress St, Ste 200 Tampa FL, 33607 Address City State Telephone Number of Designated Person: 813.574.5700 8. In addition to himself,the owner designates N/A of to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statutes. Telephone Number of Person or Entity Designated by Owner: 9. Expiration date of Notice of Commencement is one year from the date of recording unless a different date is specified: WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. STATE OF FLORIDA COUNTY OF PINELLAS Signat`u a of Owner or Owner's Authorized Officer/Director/Partner/Manager Vice President Signatory's Title/Office The foregoing instrument was acknowledged before me this 30 day of March by Steve Robert Smith as Vice President (type of�a or�ye.,g.,o cer,trustee,attorney in fact)for Lennar Homes LLC (name of party( r hom instrument was executed). Personally Known I OR Produced'Identification 0 otary.Si Type of Identification Produced Name(Print) Elissa 4 o leran Verification pursuant to Section,92.525,Florida Statutes. Under.,penalties of perjury, I declare that I have read the foregoing and that the facts stated in it are true to the best of my knowledge and belief. � ELISSAM.HOLLERAN Signature of Natural Person Signing Above ., Gmmlaslon�FF 88583T "Expires June 6,2020 wpdata/bcs/bcs form: ' bride+TbruTrby Fain Insurance 100-3i5dOtD OF A STATE OF �H COUNTY Fd EG���IS A �j THIS IS TO CEO '• TRUE AND R ORRECT OF POpy OF THE Dor UBLIC RECORD IN THIS OFFIC- Q to god WaTreat m ON FILE{� WIT SS MY HAND AND O IC1AL SEA2 T1� • k• DAY OFrl C01VtPTROLLER .pc 1887' PAULA S.AIL, ����OF�4-����� BY � �rt� DEPUTY CLERK L Y' FORM R,405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 1791A1 sf ADS Builder Name: Lennar Homes Street: 6521 Wagon Trail Street Permit Office: City of Zephyrhills City,State,Zip: Zephyrhills,FL, Permit Number:f?q Owner. Lennar Homes Jurisdiction: 6lrlb00 I Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1572.7 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1241.30 ft2 b.Frame-Wood,Adjacent R=11.0 331.33 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (1817.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1817.00 ft2 6. Conditioned floor area above grade(ft2) 1817 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(143.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 363.4 a. U-Factor: Dbl,U=0.54 87.00 ft2 SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.56 33.33 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 30.0 SEER:15.00 c. U-Factor: Dbl,U=0.56 23.00 ft2 SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 26.0 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 1.233 ft. Area Weighted Average SHGC: 0.308 14.Hot water systems 8. Floor Types (1817.0 sqft.) Insulation Area a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 1817.00 ft2 b. Conservation features EF:0.950 b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.079 Total Proposed Modified Loads: 58.07 PASS Total Baseline Loads: 58A 5 I hereby certify that the plans and specifications covered by Review of'the plans and :Q 'C :S-r .. this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. �•• rmf '`' "' .'•`'�„ O PREPARED BY: Dave AGa n h Before construction is completed94, �- DATE: this building will be inspected for compliance with Section 553.908 I hereby certify that this building,as designed, is in compliance Florida Statutes. with the Florida Energy Code. G'Ob- ti' OWNER/AGENT: BUILDING O FICIAL: DATE: E: � ^31 0 It- Compliance requires certification by the rr handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance wit R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house. 2/1/2018 7:00 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 4 t_ 1 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE :FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 1791A1 sf ADS Builder Name: Lennar Homes Street: 6521 Wagon Trail Street Permit office: City of Zephyrhills City,State,Zip: Zephyrhills,FL, Permit Number: Owner. Lennar Homes Jurisdiction: 611600 Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1572.7 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1241.30 ft2 b.Frame-Wood,Adjacent R=11.0 331.33 ft2 3. Number of units,if multiple family 1 c,N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (1817.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1817.00 ft2 6. Conditioned floor area above grade(ft2) 1817 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(143.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 363.4 a. U-Factor: Dbl,U=0.54 87.00 ft2 SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.56 33.33 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 30.0 SEER:15.00 c. U-Factor. Dbl,U=0.56 23.00 ft2 SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 26.0 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 1.233 ft. Area Weighted Average SHGC: 0.308 14.Hot water systems 8. Floor Types (1817.0 sqft.) Insulation Area a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 1817.00 ft2 b. Conservation features EF:0.950 b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.079 Total Proposed Modified Loads: 58.07 PASS Total Baseline Loads: 58.15 hereby certify that the plans and specifications covered by Review of the plans and : kYE;ST � _.. this calculation are in compliance with the Florida Energy specifications covered by this Q _ Code. calculation indicates compliance! n with the Florida Energy Code. ��VG PREPARED BY: > Mich Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 I hereby certify that this building,as designed, is in compliance Florida Statutes. with the Florida Energy Code. OWNER/AGENT: BUILDING OFFI IAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house. 2/1/2018 7:00 AM EnergyGauge@ USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 4 � y FORM R405-2017 - FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 1791A1 sf ADS Builder Name: Lennar Homes Street: 6521 Wagon Trail Street Permit Office: City of ZephyrhillS City,State,Zip: Zephyrhills,FL, Permit Number: Owner: Lennar Homes Jurisdiction: 611600 Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1572.7 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1241.30 ft2 b.Frame-Wood,Adjacent R=11.0 331.33 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (1817.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1817.00 ft2 6. Conditioned floor area above grade(ft2) 1817 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(143.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 363.4 a. U-Factor: Dbl,U=0.54 87.00 ft2 SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.56 33.33 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 30.0 SEER:15.00 c. U-Factor. Dbl,U=0.56 23.00 ft2 SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency d. U-Factor. N/A ft2 a.Electric Heat Pump 26.0 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 1.233 ft. Area Weighted Average SHGC: 0.308 14.Hot water systems 8. Floor Types (1817.0 sqft.) Insulation Area a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 1817.00 ft2 b. Conservation features EF:0.950 b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.079 Total Proposed Modified Loads: 58.07 PASS Total Baseline Loads: 58.15 1 hereby certify that the plans and specifications covered by Review of the plans andTk1E S , 7, this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance_ with the Florida Energy Code. PREPARED BY: Dave ><upich Before construction is completed s- DATE: this building will be inspected for compliance with Section 553.908 I hereby certify that this building,as designed, is in compliance Florida Statutes. with the Florida Energy Code. "-''o n'y�j : OWNER/AGENT: BUILDING OF IAL: DATE: DATE: ez - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house. 2/1/2018 7:00 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 4 e � I - FORM R405-2017 PROJECT Title: 1791A1 sf ADS Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 1817 Lot# Owner Name: Lennar Homes Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: Lennar Homes Rotate Angle: 45 :__ Street: Permit Office: Cross Ventilation: County: Pasco Jurisdiction: Whole House Fan: City,State,Zip: Zephyrhills, Family Type: Single-family FL, New/Existing: New(From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Tampa FL TAMPA_INTERNATI 39 91 70 75 645.5 54 Medium BLOCKS Number Name Area Volume 1 Block1 1817 14536 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfIIID Finished Cooled Heated 1 Main 1817 14536 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio Main 155 ft 0 1817 ft2 0.3 0 0.7 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1968 ft2 0 ft2 Medium 0.85 No 0.9 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 1817 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) Main 30 Blown 1817 ft2 0.11 Wood 2/1/2018 7:00 AM EnergyGaugeO USA-FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 4 C FORM R405-201.7 WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 N=>NE Exterior Concrete Block-Int Insul Main 4.0999 19 6 8 156.0 ft2 0 0.600000 0 2 N=>NE Garage Frame-Wood Main 11 20 8 8 165.3 ft2 0 0.01 0 3 W=>NW Garage Frame-Wood Main 11 20 9 8 166.0 ft2 0 0.01 0 4 E=>SE Exterior Concrete Block-Int Insul Main 4.0999 58 8 464.0 ft2 0 0.600000 0 5 S=>SW Exterior Concrete Block-Int Insul Main 4.0999 34 8 272.0 ft2 0 0.600000 0 6 W=>NW Exterior Concrete Block-Int Insul Main 4.0999 37 8 8 301.3 ft2 0 0.600000 0 7 S=>SW Exterior Concrete Block-Int Insul Main 4.0999 6 8 48.0 ft2 0 0.600000 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N=>NE Insulated Main None .2 3 6 8 20 ft2 2 N=>NE Wood Main None .4 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered orientation => changed to Worst Case. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N=>NE 1 Metal Low-E Double Yes. 0.56 0.28 N 23.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds None 2 E=>SE 4 Metal Low-E Double Yes 0.54 0.31 N 32.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds None 3 S=>SW 5 Metal Low-E Double Yes 0.54 0.31 N 32.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds None 4 S=>SW 7 Metal Low-E Double Yes 0.56 0.32 N 33.3 ft2 2 ft 0 in 0 ft 4 in Drapes/blinds None 5 W=>NW 6 Metal Low-E Double Yes 0.54 0.31 N 23.0 ft2 1 ft 0 in 0 ft 10 in Drapesiblinds None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 427 ft2 427 ft2 42 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) ' .000356 1695.9 93.1 175.09 .2669 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ None HSPF:8.5 26 kBtu/hr 1 sys#1 2/1/2018 7:00 AM EnergyGaugeO USA-FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 4 FORM R405-201.7 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 30 kBtu/hr 900 cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 - 40 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS / —Supply— —Return— Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 363.4 ft Main 90.85 ft Proposed Qn Main —cfm 54.5 cfm 0.03 0.60 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: CoolingJan Feb Mar A r Ma X Jun Jul Au Se Oct N Nov H Dec Heatin HJan HFeb X�Mar Apr May Jun Jul Aug �Xj Sep Oct Nov Dec Ventin Jan Feb X Mar [X A r [ Ma [ Jun Jul Au Se [X]Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 2/1/2018 7:00 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 4 FORM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerformance Index,the more efficient the home. Zephyrhills, FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1241.30 ft2 b.Frame-Wood,Adjacent R=11.0 331.33 ft 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types Insulation Area a.Under Attic(Vented) R=30.0 1817.00 ft2 6. Conditioned floor area(ft2) 1817 b.N/A R= ft2 7..Windows" Description Area c.N/A R= ft2 a. U-Factor. Dbl,U=0.54 87.00 ft2 11.Ducts R ft2 SHGC: SHGC=0.31 a.Sup:Attic,Ret:Main,AH:Main 6 363.4 b. U-Factor: Dbl,U=0.56 33.33 ft2 SHGC: SHGC=0.32 12.Cooling systems kBtu/hr Efficiency c. U-Factor. Dbl,U=0.56 23.00 ft2 a.Central Unit 30.0 SEER:15.00 SHGC: SHGC=0.28 d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 26.0 HSPF:8.50 Area Weighted Average Overhang Depth: 1.233 ft. Area Weighted Average SHGC: 0.308 8. Floor Types Insulation Area 14.Hot water systems a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 1817.00 ft2 EF:0.95 b.N/A R= ft2 c.N/A R= ft2 b. Conservation features None 15.Credits Pstat certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. ' ./nrf ; .;;;�. Builder Signature: Date: 02/05/18 . Address of New Home: 6521 Wagon Trail Street City/FL Zip: Zephyrhills,FL 3354Y.. *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 2/1/2018 7:02 AM EnergyGauge@ USA-FlaRes2017 -Section R405.4.1 Compliant Software Page 1 of 1 Building Analysis Job: 1791A1 sf ADS Y Date: 2/5/2018 Entire House By: Dave Bayonet Plumbing Heating and Air Project Information For: Lennar Homes Design Conditions Location: Indoor: Heating Cooling Tampa International AP, FL, US Indoor temperature(OF) 70 75 Elevation: 10 ft Design TD (OF) 39 16 Latitude: 280N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 34.7 54.7 Dry bulb(OF) 31 91 Infiltration: Daily range(OF) - 14 ( L ) Method Simplified Wet bulb(OF) - 77 Construction quality Semi-tight Wind speed(mph) 15.0 7.5 Fireplaces 0 _0100"Mn Component Btuh/ft2 Btuh % of load Walls 5.6 6529 25.4 Ucts Glazing 30.2 4772 18.6 wall Doors 23.5 466 1.8 nfiltration Ceilings 1.3 2271 8.8 Floors 3.4 6125 23.9 Infiltration 2.2 2887 11.2 Ducts 2616 10.2 Piping 0 0 Glazing Floors Humidification 0 0 Ventilation 0 0 Other Ceilings Adjustments 0 Total 25667 100.0 Component Btuh/ftZ Btuh % of load Walls 2.8 3248 14.3 Walls Glazing 48.5 7667 33.7 Internal Gains Doors 18.4 365 1.6 Ceilings 1.7 3140 13.8 Floors 0 0 0 Infiltration 0.5 647 2.8 r Ducts 2982 13.1 Ducts Ventilation 0 0 Internal gains 4728 20.8 Glazing 'Blower 0 0 Infiltration Adjustments 0 Total 22775 100.0 Other Ceilings Latent Cooling Load= 3725 Btuh Overall U-value= 0.104 Btuh/ft2-°F Data entries checked. .` Wrl htsoftm 2018-Feb-0510:50:17 9 Right-Sufte®Universal 2017 17.0.23 RSUD5714 Page 1 h CBA27UHE AH's11791 sf ADS template 2.5ton.rup Calc=MJ8 Front Door faces: E Project $L11Y11Y1a Job: 1791A1 sf ADS Pro Summary Date: 21612018 Entire House By: Dave Bayonet Plumbing Heating and Air Project Information For: Lennar Homes Notes: 40'ADS-2017 Design Information Weather: Tampa International AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 31 OF Outside db 91 OF Inside db 70 OF Inside db 75 OF Design TD 39 OF Design TD 16 OF Daily range L Relative humidity 50 % Moisture difference 55 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 23051 Btuh Structure 19794 Btuh Ducts 2616 Btuh Ducts 2982 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 25667 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 22775 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 3191 Btuh Ducts 534 Btuh Central vent(0 cfm) 0 Btuh Heating cooling (none) Area(ft') 1819 181g Equipment latent load 3725 Btuh Volume(ft') 15459 15459 Air changes/hour 0.26 0.14 Equipment Total Load (Sen+Lat) 26501 Btuh Equiv.AVF (cfm) 67 36 Req. total capacity at 0.85 SHR 2.2 ton Heating Equipment Summary Cooling.Equipment Summary Make Lennox Make Lennox Trade 14HPX SERIES Trade 14HPX SERIES Model 14HPX-030-230-21 Cond 14HPX-030-230-21 AHRI ref 10258600 Coil CBA27UHE-030-230*++TDR AHRI ref 10258600 Efficiency 8.5 HSPF Efficiency 13.0 EER, 15 SEER Heating input Sensible cooling 25500 Btuh Heating output 26400 Btuh @ 47'F Latent cooling 4500 Btuh Temperature rise 24 OF Total cooling 30000 Btuh Actual air flow 1000 cfm Actual air flow 1000 cfm Air flow factor 0.039 cfm/Btuh Air flow factor 0.044 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.86 Capacity balance point= 31 OF Backup: n/a n/a Input= 0 kW, Output= 0 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Wrl htsoft- 2018-Feb-051650:17 :4C K "r g Right-Suite®Universal 2017 17.0.23 RSU05714 Page 1 h CBA27UHE AH's\1791 sf ADS template 2.5ton.rup Calc=MJ8 Front Door faces: E Manual S Compliance Report Job: 1791A1 sf ADS Date: 2/5/2018 Entire House By: Dave Bayonet Plumbing Heating and Air Project Information For: Lennar Homes Cooling Equipment Design Conditions Outdoor design DB: 91.3°F Sensible gain: 22775 Btuh Entering coil DB: 75.7°F Outdoor design WB: 77.3°F Latent gain: 3725 Btuh Entering coil WB: 62.8°F Indoor design DB: 75.0°F Total gain: 26501 Btuh Indoor RH: 50% Estimated airflow: 1000 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Lennox Model: 14HPX-030-230-21+CBA27UHE-030-230*++TDR Actual airflow: 1000 cfm Sensible capacity: 25500 Btuh 112% of load Latent capacity: 4500 Btuh 121% of load Total capacity: 30000 Btuh 113% of load SHR: 85% Heating Equipment Design Conditions Outdoor design DB: 30.8°F Heat loss: 25667 Btuh Entering coil DB: 69.6°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Lennox Model: 14HPX-030-230-21+CBA27UHE-030-230*++TDR Actual airflow: 1000 cfm Output capacity: 26000 Btuh 101% of load Capacity balance: 31 °F Supplemental heat required: 0 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: n/a Model: n/a+n/a Actual airflow: 1000 cfm Output capacity: 0 kW 0% of load Temp. rise: 0 °F Meets are all requirements of ACCA Manual S. C wri htsoft® 201&Feb-0510:50:17 ,.." 9 Right-Suite®Universal 2017 17.0.23 RSU05714 Page 1 ...h CBA27UHE AH's11791 sf ADS template 2.5ton.rup Calc=MJB Front Door faces: E PASCO COUNTY, FLORIDA Permit No, d date Permitted Buiider Name/Owner Name .to-Arla-+r f"es 41c'Control# County Parcel No. 0,�-2-{ -2-(- i2(;80 -C O&w.o3y6 SubDiv: . &� 6'" Address/Location �6z t[ Classification/Type of Use TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: Exempt ❑Yes ❑ No How Determined i Impact Fee Amount $31 b 32 - Zone No. TAZ: 3 SCHOOL IMPACT FEE Account (056) Single-Family Detached House Amount $ '7� If 2-6• 00 (057) Mobile Home (058) Other Residential 923) Collection Fee Exempt [{] Yes ❑ No How Determined PARKS AND RECREATION FEE Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation Total Zone TOTAL AMOUNT $ 7�::/• , Exempt ❑Yes ❑ No How Determined LIBRARY FEE Land Account Land Credit Land Total Facility Account Facility Credit Facility Total Exempt ❑ Yes ❑ No How Determined Total Amowg'� " RESOURCE FEE ERU TOTAL AMOUNT Prepared By Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTIN©OFFICE.OF PASCO COUNTY • I Acknowledgement below does not Imply acceptance of concurrence,but simply receipt of-a copy of this form,placing the building permit owner on notice of this assessment and thQ conditions of payment for same. DATE RECEIVED BY RECEIPT NO. DATE BY 05-26-21-0080-00600-0340 Pasco County Property Appraiser Page 1 of 1 Data Current as Of: Weekly Archive - Saturday, April 21, 2018 Parcel ID 05-26-21-0080-00600-0340 (Card: 001 of 001) Classification 00 - Vacant Residential Mailing Address Property Value LENNAR HOMES LLC Ag Land .$0 4600 W CYPRESS ST STE 200 Land $24,347 TAMPA FL 33607-4099 Building $0 Physical Address Extra Features $0 6521 WAGON TRAIL STREET ZEPHYRHILLS, FL 33541 Just Value $24,347 Legal Description (First 4 Lines) Assessed (Non-School Amendment 1) $24,347 See Plat for this Subdivision Taxable Value $24,347 SILVERADO RANCH SUBDIVISION PHASES 6, 8 &9A PB 75 PG 075 BLOCK 6 LOT 34 - Jurisdiction City of Zeghyrhills Land Detail (Card: 001 of 001) Line ;Use jDescription,Zoning Units ype� lPrice Condition !Value 1 i 0100 SFR _ MPUD _ 6,000.00 _ _SF_ $4.00__ 1.00 $24,000_ 2 0100 SFR MPUD 867.00 SF $0.40 1.00 $347 Additional Land Information FEMA Acres j 0.16 Tax Area! 30SI 1 Code k -- Residential Code SLVRLPI ! i f Building Information - Use 00 - Unimproved (Card: 001 of 001) Unimproved Parcel 00 - Unimproved ___,,-_..—_._ Extra,Features (Card: 001 of 001) Line _^ _ !Description 1year _____ Units _—_(Value No Extra Features Sales History - See All 6 sales Previous Owner: DUNE FL LAND I SUB LLC Month/Ye rBook/Page _ jType rD�OR Code_Condit o�nAmount 04/2018—?709 / 2014 ( Warranty Deed ^I 05 Vacan Multi-Parcel Sale _05/2017_ 19_535_/ 0546_ _ Certificate_of-Title - --i 05 Vacant Multi-Parcel Sale 11/2016 �9462 / 0384 (Mineral Rights or Royalty Transfer! 05 i Vacant Multi-Parcel Sale http://search.pascopa.com/parcel.aspx?parcel=2126050080006000340 4/23/2018 'UTOTY If 5 { ry°c 1z3. LOT 46 PAD�=123.4 ,-'- ti'b X12v ET, K ' TYPE A,( 120.03 ,I'N r �, ! FF;— 20,90 FF'=122.20, xL 45 "LOT 4,4' PAD=122.2 ' PAD- l21.5 ; 12415' T<(PE A PER! YPE r t ANt� pRAINAGE,-EASME I 1 ' cS �x121.87 f .5.34 t,•�, A x 123.83 x 1 r!Z3.27 Bj/t 6t X 12 8 3.3 -' t x 124.6 ol i ,' A 3 1/23.6 t r ll A t ` ` F LOT 0 F ' PAD=1'1�7.5 ' , ! PAq-117.5 , f 1$.02 r "118:9 1 ,/'TYPE A TYJPt•A ' ,-` LOT 40 ;{' PAD=118.2 ' ,FEE D LA, SCAP ! TYPED{ , .y_..61 ` J LOT 39 ', II PAD=119:6 ,,�• ' $ CD , - , ,, It 117 IT7000 FF=1�0.Q30 �� r ,jj� LOT, 38 1 { t „6.6 ♦'' r{ `rFx117.6}V'!' i a' PAD=119.6 ; t ' �_'_ '� PLOT 3 / TYPE A ,' r% ! i 'PAD=116,0 F TYPE 8 I' U , ! , •! ! ' o { - FF�118 70,-` ,�,Yc, ,r''' 'LOT ��' ` . t r� ,PAD-3118 0 ,,- LOT • ; , 'y� , T�E A' ,'' r { { PAD-114.1 '' k. oc ,' ,�` .4� ' ` A} ti� �. , ' TYPE' B ��. 't , co Xlll�.43 { S rPF=116.30 ,/ t CL LOT 36 { ' ' ct� PAD=115.6 .-'� t LOT' ,! w' - '' t"�a?r ro TYPE A r { ' PAD-1J15.1 °a 03 ! TYPE B ; �•• , i7i ' . ,is. LOT 35 0=114.84 o hg•'' , PAD=114.6 '"{ �' t LOT a t { r► t PAD=11'4.1 Xi 4.11 TYPE A , A, J 114.40, / t ` 11149" LOST 11' � ri y .FF-113. t�' PAD ' J co ° {N ' YPE , ;%`-=' r �' ,' O { , LOT 7 d � _ _ { /! PAD=11`3.2 TY LOT' 33 t - 00+ A TYPE A PAT112.4 , ° TYPE B ;• f` pshe nh ( `j- O • i , SKETCH ONLY SEC. 05 TWP. 26 S, RNG. 21 E. PLOT PLAN NOT A BOUNDARY SURVEY BEARING BASIS: LOT 34, BLOCK 6 SILVERADO RANCH SUBDIVISION PHASES 6, 8 & 9A EAST BOUNDARY OF SUBJECT PLAT BEING N 0235'32" E PASCO COUNTY, FLORIDA. fi T THIS SURVEY IS SUBJECT TO ANY FACTS THAT PRELIMINARY DRAWING: ON LOT AREA CALCULATIONS 1 MAY BE DISCLOSED BY A FULL AND ACCURATE TITLE SEARCH. ALSO SUBJECT TO SETBACKS, THIS PLAN IS FOR PERMITTING PURPOSES LOT = 6866.98_SQ. FT. EASEMENTS AND RESTRICTIONS OF RECORD. ONLY, NOT FOR CONSTRUCTION. VERIFY LIVING AREA = 1838_SQ. FT. ALL DIMENSIONS BEFORE ANY CONSTRUCTION: ENTRY = 32 SQ. FT. M UNDERGROUND FOOTER, STEM WALL, AND GARAGE = 406 _SQ. FT. II UNDERGROUND UTILITIES ARE NOT LOCATED OR LEGEND' COVERED LANAI =�A SQ. FT. SHOWN. l►= PROPOSED DRAINAGE FLOW PATIO = 23 Q. FT. CONC. DRIVE = 339 $q• FT. ui DO NOT SCALE THIS PRINT. DIMENSIONS AND (00.00) = PROPOSED GRADE A/C & CONC PAD = 18 Q. FT. J NOTES TAKE PREFERENCE. E-00.00 = EXISTING GRADE ¢ PRIVATE SIDEWALK = 72 SQ. FT. En DESCRIPTION NOT CONTAINING PLAT BOOK AND NOTES: IMPERVIOUS = 40 PAGE INDICATES THAT PLAT IS IN 2728 Q. FT. PRELIMINARY STAGE AND IS SUBJECT TO LOT GRADING TYPE = A SOD = 4139 SQ. FT. CHANGE AND/OR REVISION. PROPOSED PAD ELEVATION = 113.7' FRONT SETBACK = 20' OFF LOT AREA CALCULATIONS CERTAIN DATA SHOWN HEREON BASED ON SIDE SETBACK = 7.5' RIGHT OF WAY = 990.00 Q. FT. ENGINEERING PLANS PROVIDED BY CLIENT. REAR SETBACK = 15' DRIVE APRON = 133 SQ_ FT. PUBLIC SIDEWALK = 275 _SQ. FT. * = 10' UTILITY EASEMENT SOD = 482 SQ. FT. **'= 15' DRAINAGE EASEMENT TOTALS AREA = 7856.98 SQ. FT. DRIVEWAY = 572 _SQ. FT. SIDEWALK = 347 Q. FT. PC(P) SOD = 4621 Q. FT. LOT 35 BLOCK 6 ml. rz rl r,, �o. ?� S 87'24'28" E 124.86' r" f-- J� sr- l_ I w `0 30.00 1...45.02'................ n n ............36.17`' fY O L0 1........ O ',a'..... :,. F: 2..7' O I a. L6 ZEPHYRHILLS COLONY COMPANY _ I w� PLAT BOOK 001, PAGE 055 J~ EOa ¢ OO CN a- En nN 20.50' a . Ir w V ¢ O Z9 Cy ..................n 0 :o \of .....20. 0' .p. .u) _ N �k�°kry ��ti N 87'24'28" W 124.86_� f` . .. �yb 30.00 PLAT 3 BOUNDARY v LOT 33 BLOCK 6 Y J ' m 01 Co Z PROPOSED: o LOWEST FLOOR ELEVATIONS: ¢ LIVING AREA: 114.40' w DESCRIPTION: GARAGE AREA: ELEVATIONS REFERENCED TO a LOT 34, BLOCK 6, MAP OR PLAT ENTITLED "SILVERADO RANCH SUBDIVISION PHASES NORTH AMERICAN VERTICAL 6, 8 & 9A", AS RECORDED IN PLAT BOOK 075, PAGES 075 THROUGH 080, OF THE DATUM OF 1988. MEAN SEA a PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. LEVEL= 00.00 FT. a0 APPARENT FLOOD HAZARD ZONE: "X" COMMUNITY PANEL NO. 120230 0455 D EFFECTIVE DATE: 09/30/1992 LEGEND: (C)= CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, g= CENTERLINE, A/C= AIR CONDITIONER, B/C= BACK OF CURB, C/S= a CONCRETE SLAB, CH= CHORD, CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= COVERED,-E/P= EDGE OF PAVEMENT, ESM'T= EASEMENT, -F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE, FIR= FOUND IRON ROD, FN&D=.FOUND NAIL & DISK, FPP= FOUND PINCHED u PIPE, LFE= LOWEST FLOOR ELEVATION, MAS.= MASONRY, OR= OFFICIAL RECORD BOOK, PB= PLAT BOOK-,PCP= PERMANENT CONTROL POINT, PRM= PERMANENT ¢z REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & CAP No. 4493,E SN&D=.SET-NAIL &:DISK, TBM= TEMPORARY BENCHMARK, Ir U P= UTILITY POLE, W F= WOOD FENCE, R = RADIAL - - — a JOHN R.BEACH&ASSOCIATES,INC. Drawn By. SMS Square Feet: 6866.98 t, LENNAR HOMES w SURVEYORS AND MAPPERS 1 911 WEST ST. PETERSBURG DRIVE Checked By. JRB u) ONE OLDSMAR, FLORIDA 34677 N WAY (813) 854-1276 FAX (813) 855-8370 Scale: 1"=30' C a NOT VALID WITHOUT THE SIGNATURE AND Date: PLOT PLAN 1 31 18 ACS ZAO 'a THE ORIGINAL RAISED SEAL OF A FLORIDA 0HN BEACH DATE N LICENSED SURVEYOR AND MAPPER FLORIDA 1WG. LAND SURVEYOR No. 2984 LB#4493 Revisions: Single Family Dwelling Plan Review Comments 1: F.F.E. shall be a minimum of 8" above.the road elevation and an engineered site plan. 2.- Lots shall be graded to comply with R401.3 of the F.B.C. 3. -Compaction test required if 24' or more of fill dirt is brought in:at any one place: 4: Tie in survey required before pouring concrete. 5. -Driveways:require a R.O.W. use permit. All 4:sides of driveway thru the sidewalk shall have . -expansion material: 6. All setbacks.shall be met.; 7.. All property.markers shall be.uncovered and marked at time of first-inspection: 8. All A.D.A. requirements shall:be met. . 9. No electric,plumbing, mechanical, or(framing shall be covered without an inspection and approval first. . I O.A.11. Garages shall.comply.with section R302:6 of the F.B.C. (Fire Separation). 11. Appliances.shall not be installed in a location where subject to mechanical damage unless protected by approved barriers. M303.4 of the F.B.0 12. Water heaters shall comply with section P607.3 of the F.R.C. 13. Foundation supports_for A/C units shall be raised at least 37 above_ finished grade. M1309.1 14. Return air in all bedrooms. F.B.C. M1620A. 15. Smoke detectors are.to be'installed in-accordance with:R313:1 of the.F.B.C. 16::A11 glazing requirements are.to be in accordance with R308.4.of the F.B:C. 17. All means of egress are'to.be in accordance with R31 L-of the F.-B.C. 18. `.`Green gypsum board" shall not be used as.a backer in showers or tubs.R702.4:2.F.B.-C. 19. Combination-type AFCI breakers are required,at all locations requiring an AFCI type breaker. 20. Carbon-monoxide alarms will.be required in new construction that uses fossil-burning heating or appliances or-an attached garage: They ; shall be instahed in accordance with the F.B.C.. 21. All plumbing mechanical,'and electrical shall be separate from unit to unit. This includes all. underground plumbing and electric: '22. All 2011.N:E:C: Codes'will.be enforced: 23.Tamper- Resistant Receptacles in accordance with 40.6.11 of the 2011 N:E:C 24:.In accordance.With the Land.Development Code, lots shall be sodded before final at least 10 feet:around the structure: 25.A.copy of the energy cacls shall be with permit at all times 26 Com of rinal.insulation report shall be provided with.permit.before.ihaL EEE.=Finished Floor Elevation F.B.C-Florida Building Code 6t'Edition. R.O.W.-Right of Way A.D.A.-Americans with Disabilities Act N.E.C.-National.Electric Code(2011): t , ' Fa�a �780�V21 81a�u�O�o City of USP�m� �g�OD pm~� . ' Building Department . ^ Date Received Phone Contact for Permitting 111 .1111 » xxnox Owner's Name Lermar Homes,LLC .Owner Phone Number 813.574.5700 Owner's Address 4600 ress FL 33607 Owner Phone Number Fee Simple Titleholder Name I Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS il LoT# [0340 ����___� SVBow|Smm SlIverado Ranch Subdivision Ph 2,3,&4pAmcEL|o# 0340 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED wswcowsrn Aoo/A|T �--� SIGN �—1 [--1 DEMOLISH P INSTALL [_� REPAIR PROPOSED USE 0arn �—1 COMM [---� oT*ER TYPE oFCONSTRUCTION U�� o�oom [—� rm^�� F--� STEEL y��' �—� `---^ ^—� DESCRIPTION orWORK [Rngle Family Residence Pool/Screen Enclosure Fence 2276 =] BUILDING SIZE SQ FOOTAGE[/���_� J xs|$Mr 1 Story BUILDING VALUATION OF TOTAL CONSTRUCTION PLUMBING $ LZi MECHANICAL 1$ VALUATION OF MECHANICAL INSTALLATION �� [--lGm» h� | nooF|wo [—� SPECIALTY� OTHER ^�—^ J--} �—l. FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA � fYES | �O BUILDER COMPANY Lermar Homes,LLC a|GmAruRs REGISTERED Y/_N_ rsscvRns^ Address 14600 FL 33607 Licenoo# ELECTRICIAN COMPANY Edmonson Electric, Inc. SIGNATURE REGISTERED Y/_N_ rsscumnsx �_� Address Umanoa# PLUMBER a|Gm/TuRs REGISTERED _Y/ N_ rsscuxns^ L_1/NL� Address License# Meo*Am|oxL COMPANY Kayonet Plumbing, Heating &AC, Inc o|am/nuRs REGISTERED _l/ N FssuunnsN i_ILN_j Address uuanon oTwsm coMpAwr a|ow/nnRs nsmmsneu LY/_N_ FEEcumnEN Address 14211 Shoal Line Blvd, Spring Hill, FL 34607 L|mmao# m x x x m x x n m x x m n x u n x x u o x'x m x x m m x x m n n o u n u w x x x m n n m o x x m x x u v x x m x o x m x x m x x x w x RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(1o)working days after submittal date. Required pnnua.Construction Plans,0nnnwater Plans w/Silt Fence installed, Sanitary Facilities a1dumpotacSite Work Permit for mubu|vioionm|argeprojects COMMERCIAL Attach;q complete sets uY Building p|onup|uaame8ofetyPogo;(1)meuvfEnnrgyFonno.n'O-WPermit for new construction. Minimum ten(1o)working days after submittal date. Required 000Ke.Construction Plans,0onnvnaor Plans w/Silt Fence installed, Sanitary Facilities&1dumputec Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ****PROPERTYou ui for all NEW construction. Fill out application completely. Owner&Contractor sign back o[application,notarized n over$osoo.o Notice n,Commencement iamovireu. (AVn upgrades over$7so0) ~° Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER pEmmrrTINo (copy ofcontract required) Remofs if shingles Sewers Service Upgrades /Vo Fanmm(P|m0unvey/Fnotage) Driveways-Not over Counter Ifun public modwayo'neeu ROW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject'to"deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner" prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone W" unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90) consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. FLORIDA JURAT(F.S. 117.03) OWNER OR AGENT I CONTRACTOR Subscribed and sworn to(or affirmed)bef4rla me this Subscribed and sworn to r affirmed)before me this ou-pan-[a by Paul Sweeney 30Jen-10 by Paul Aene Who is/are personally known to me or hasWave predised- Who is/are personally knbw6 to me or as identif[,ation. as identification. 1 Notary Public Notary Public Commission No. FF98537 Co [ssion No. 8537 Elissa M.Holleran Elissa M.Holleran Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped �t195J,�.pl�Ut�lMI' ,ti l�rr�d?on[�r3�liteasa ,a l �[rm�'aniM.pp�per�GT uiglpk� Ir��1�9�G UMW 'Play alaerLaoe le;,t411 - Bdd4�a[nF�ailsaa� tlWflli — — 05-26-21-0080-00600-0340 Pasco County Property Appraiser Page 1 of 1 Data Current as Of: Weekly Archive - Saturday, April 21, 2018 Parcel ID 05-26-21-0080-00600-0340 (Card: 001 of 001) Classification 00 - Vacant Residential Mailing Address Property Value LENNAR HOMES LLC Ag Land $0 4600 W CYPRESS ST STE 200 Land $24,347 TAMPA FL 33607-4099 Building $0 Physical Address Extra Features $0 6521 WAGON TRAIL STREET ZEPHYRHILLS, FL 33541 Just Value $24,347 Legal Description (First 4 Lines) Assessed (Non-School Amendment 1) $24,347 See Plat for this Subdivision Taxable Value $24,347 SILVERADO RANCH SUBDIVISION PHASES 6, 8 &9A PB 75 PG 075 BLOCK 6 LOT 34 Jurisdiction City of Zephyrhills _ Land Detail (Card: 001 of 001) _ Line—Use J Descrip—Description—n��Zoning Units i_Type Price jCondition ;Value 1 _ 0100 SFR {I _MPUD _ 6,000.00 ; ^SF $4.00 � 1.00�{ $24,000 2 _� 0100 SFR — I� MPUD 867.00 SF $0.40 1.00 ! $347 Additional Land Information Acres 0.16 Tax Areal 30SI �EMA- - — Y Residential Code SLVRLPI Code I I Building Information - Use 00 - Unimproved (Card: 001 of 001) Unimproved Parcel 00 - Unimproved Extra Features 001 of 001) Line Description iYear __ Units Value_ No Extra Features Sales History - See All 6 sales Previous Owner: DUNE FL LAND I SUB LLC Month/Year Book/Page Type D_OR Code ConditionAmount _ _ 04/2018 9709 / 2014 _Warranty Deed 05 Vacant Multi-Parcel Sale 05/2017 19535 / 0546 Certificate of Title 05 �_ _Vacant Multi-Parcel Sale 11/2016 19462 / 0384 Mineral Rights or Royalty Transfer 05 Vacant Multi-Parcel Sale http://search.pascopa.com/parcel.aspx?parcel=2126050080006000340 - 4/23/2018 Lennar Homes 6651 Wagon Trail St. 2,276 sq ft Column SQ. FEET PRICE MAIN OR LIVING: 2,276 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 256,391.40 FEE SHEET $ 1,325.00 ADDRESS $ 40.00 DRIVEWAY $ 40.00 BUILDING: $ 1,431.50 ELECTRICAL: $ 298.13 PLUMBING: $ 198.75 MECHANICAL: $ 139.13 SUB-TOTAL $ 2,067.50 TOTAL $ 2,067.50 SEWER: WATER: IRRIGATION: $ - TOTAL: $ - WATER METER: IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 2,620.85 PARK IMPACT FEES $ 769.56 SIF'S: $ 7,128.00 100.0% $ 7,128.00 1.0% $ 71.28 TOTAL: $ 7,199.28 T I F'S : $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 14,221.69 • �C\3�/ IiLU 111 Un City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: Date Received: Site: 5z� �Q L Permit Type: 6C41t 1 QU 2 Z G Approved w/no comments:❑ Approved w/the below comments: Denied w/the below comments: ❑ This comment sheet shall be kept with the permit and/or plans. e r 0 1 (pj/— Kalvin Swi ze Plans Examiner Date Contractor and/or Homeowner (Required when comments are present) • 5335 - 8TH STREET (813)780-0020 CERTIFICATE OF OCCUPANCY Address: 6521 WAGON TRAIL ST Owner: LENNAR HOMES LLC ZEPHYRHILLS, FL. 4600 W CYPRESS ST STE Subdiv: SILVERADO TAMPA FL 33607-4099 Parcel: 05-26-21-0080-00600-0340 Work Type: 101-NEW CONST/SFR Construction Type: NOT APPLICABLE ❑ Sprinklers Use Classification: NOT APPLICABLE Permit Number: 19601 Date: 7/30/2018 0 ev-�,,e- &Q�— iFICA:11 H2-�� ISSUE Y: BUILDI OFFICIAL : WATER MUST BE CHANGED OVER WITHIN 10 DAYS OF ISSUANCE GARBAGE DEPOSIT MUST BE APPLIED FOR PRIOR TO ISSUANCE ADDRESS ING,:DEPARTMENT GIS /ADDRESSING t PASCO COUNTY'GOVT. CENTER 7 � - 8731 CITIZENS DRIVE;SUITE 310 ! NEW PORT RICHEY;FL 34654 Phone: (727)815-7154 http://www.peiscocounto.net/ August 21, 2018 To Whom It May Concern: Re: Parcel ID# 05 26 21 0080 00600 0340 This is to confirm that the correct 911 approved address for the above mentioned parcel ID# is: 6621 Wagon Trail Street, Zephyrhills, FL 33541 It was necessary to change this address in order to comply with E911 and National Emergency Number Association (NENA) standards The old address for the above mentioned parcel ID#was: 6521 Wagon Wheel Street, Zephyrhills, FL 335471 Should you have any questions, please do not hesitate to contact this office. Sincerely, PASCO COUNTY ADDRESSING DEPARTMENT J cm WaPtm Pam Walton GIS/Addressing Analyst