Loading...
HomeMy WebLinkAbout18-19646 CITY OF ZEPHYRHILLS = 5335 - 8TH STREET (813) 780-0020 1964 EMERGENCY GENERATOR PERMIT PERMIT INFORMATION = LOCATION INFORMATION Permit Number: 19646 Address: 37815 15TH AVE Permit Type: FIRE EMERG GENERATOR<30K ZEPHYRHILLS, FL. Class of Work: FIRE-EMERGENCY GENERATOR Township: Range: Book: Proposed Use: COMMERCIAL Lot(s): Block: Section: Square Feet: Subdivision: CITY OF ZEPHYRHILLS Est. Value: Parcel Number: 10-26-21-0600-00000-0010 Improv. Cost: 3,789.00 OWNER INFORMATION Date Issued: 5/03/2018 Name: JOSEPH, JOSEPH Total Fees: 145.00 Address: 37815 15TH AVE WEST Amount Paid: 145.00 ZEPHYRHILLS, FL. 33542 Date Paid: 5/03/2018 Phone: Work Desc: INSTALLATION EMERGENCY GENERATOR W/ELECTRIC CONTRACTORS APPLICATION FEES CHRIS ELECTRIC SERVICES LLC FIRE PERMIT FEES 100.00 ELECTRICAL FEE 45.00 CHRIS ELECTRIC SERVICES LLC n �Y 4Rei FIRE INSTALLATION-Final Inspections ELECTRICAL FINAL FINAL Chapter 633, Florida Statutes,authorizes the City to charge and collect user fees to pay for the costs of fire' prevention and protection related activities such as inspections, plan review,administrative fees,and other costs related to the aforementioned. Complete Plans, Specifications and Fee Must Accompany Application. Commencement of work without written approval of the Fire Department's Fire Marshal or required permits or opening up for commercial activity without an approved final inspection shall be charged double permit fee per day of operation or a minimum of$100.00, whichever is greater. All work shall be performed in accordance with City Codes and Ordinances. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.eAur,,�'Llp XJLZ� CONTRACTOR SIGNATURE PERMIT OFFICER PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED ZEPHYRHILLS FIRE RESCUE - 813-780-0041 813-780-0020 City of ZephyrhiilS Fire Fax-813-780-0021 Permit Application i Date Received � Phone Contact for Permit - �_- Owners Name n n e 12 Ift Owner's Phone Number Owner's Address .- P *� _ Y L S f0 k&_ 3 35^ Fee Simple Titleholder Name F Titleholder Phone Number Fee Simple Titleholder Address r - Job Address Lot# Sub Division Parcel# o Bio-Hazard Waste Storage-ANNUAL Fumigation Tent Comm Exhaust Kitchen HoodlDuct Hazardous Material(Tier II or RQ Facility)ANNUAL oControlled Burn Hood Installation Emergency Generator<30 kw LP/Natural Gas-Installation Emergency Generator>30 kw LP/Natural Gas-ANNUAL Sale QFire Protection Maintenance-ANNUAL Places of Assembly-ANNUAL try emi Fn-q MtTe-F-1 Sprinkler ❑ ❑ ❑ Recreational Bum Fire Alarm ❑ ❑ ❑ Sparklers Hood Cleaning ❑ ❑ ❑ Sprinkler System Installations Hood Suppression ❑ ❑ ❑ Standpipes(Sprinkler Sys) Fire Alarm Installation Torch Roofing/Tar Kettle" Fire Pumps a W to„T#e$torag NNUAL ❑ Flammable Application-ANNUAL ,j Valuation of Project ❑ Fuel Tanks QOther: Contractor Company l Signature Registered Y F e Current / Address License# ELECTRICIAN Company ( C (C es Signature Registered Y/N Fee Current Y/N Address ( rj r "~ t License# ' Q PLUMBER Company Signature Registered Y/N Fee Current Y/N Address License# MECHANICAL Company Signature Registered Y/N Fee Current Y!N Address License# OTHER Company Signature Registered Y/N Fee Current Address License# Directions: t Fill out application completely. Owner&Contractor sign back of application,notarized(Or,copy of signed contract with owner) If over$2500,a Notice of Commencement is required(Mechanical work over$5000) Supply two(2)sets of drawings with applicable documentation Allow 10-14 days for review after submittal date. Parcel#-obtained from Property Tax Notice(http://appraiser.pascogov.com) NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restrictions" which may be more restrictive than County regulations. The undersigned assumes_responsibility for.compiiance with any 'applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible.. If you, as the owner sign as the contractor, that maybe an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes,as amended): If valuation of work is $2,500.00 or more, I certify that 1, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide' prepared by the Florida Department of Agriculture and Consumer Affairs: if the applicant is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner' prior to commencement. - CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating 'construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of'other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. If i am the AGENT FOR THE OWNER, 1 promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter' requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by-such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety(90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER'OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. FLORIDA JURAT(F.S.117,03) OWNER OR AGENT CONTRACTOR Subscribed and sworn to(or affirmed)before me this Subscribed and sworn to(or affirmed)before me this by by Who is/are personally,known to me or has/have produced'. Who is/are personally known to me or has/have produced as Identification. as identification. Notary Public Notary Public Commission No. Commission No. Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped t - /�� I'LOfl1Ufl i City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: Date Received: Site: J�����l "Ike- Permit Type: W -00i C �( Approved w/no comments: Approved w/the below comments: ❑ Denied w/the below comments: ❑ This comment sheet shall be kept with the permit and/or plans. ��- 5 -3 -d K 1 Tans Examiner Date Contractor and/or Homeowner aelAe, /&d, _ l - (Required when comments are present) Model: 30RC:L KOHLER. Power Syste ms Multi-Fuel Natural Gas/LPG 09001 Standard Features • Kohler Co.provides one-source responsibility for the •..�C°rry HL isrFMs NATIONALLY REGISTERED generating system and accessories. « The generator set and its components are prototype-tested, facto built, and production-tested. 77, • The generator set accepts rated load in one step. •xY, ''` _ _� • A standard five-year or 2000 hour limited warranty covers all :. •. v w`s, =,,; `. wx; -~_== systems and components. ?g,`_ r Quick-ship QS models with selected features are available. See your Kohler distributor for details. ' rx ".• i"+ =� • RDC2 Controller o One digital controller manages both the generator set and_ a transfer switch functions (with optional Model RXT Ir, transfer switch). o Designed for today's most sophisticated electronics. o Electronic speed control responds quickly to varying household demand. o Digital voltage regulation protects your valuable electronics from harmonic distortion and unstable power The Kohler Advantage quality. • High Quality Power o Two-line, backlit LCD screen is easy to read in all lighting Kohler home generators provide advanced voltage and conditions,including direct sunlight and law light. frequency regulation along with ultra-low levels of • Engine Features harmonic distortion for excellent generator power quality to o Powerful and reliable 2.2 L turbocharged liquid-cooled protect your valuable electronics. engine o Electronic engine management system. • Extraordinary Reliability o Simple field conversion between natural gas and LPG Kohler is.known for extr ary reliability and fuels while maintaining emission certification. W- perform . I ium five-year or • Innovative Cooling System 2000 hoter o Electronically controlled fan speeds minimize generator « A1GAtu CCC' ul1 �� set sound signature. • Certifications « Quiet Operation o The 60 Hz generator set engine is certified by the Kohler home generators pre,5P t�' 0,hghborhood- Environmental Protection Agency(EPA)to conform to the friendly pert�rma�q� New Source Performance Standard (NSPS)for stationary R of @ 1N spark-ignited emissions. e�j ADD LIFE 8 o UL 2200/cUL listing is available(60 Hz only). o CSA certification is available(60 Hz only). o Accepted by the Massachusetts Board of Registration of AM WORK SHALL COMPLY WITH Plumbers and Gas Fitters. NFFA CODS6 AND STANDARDS • Approved for stationary standby applications in locations Generator Set Ratings served by a reliable utility source. Standby Ratings Natural Gas LPG Alternator Voltage Ph Hz kW/kVA Amps kW/kVA Amps 4E5.6 1201240 1 60 30/30 125 ' 30/30 125 120/208 3 60 30/37 104 30/37 104 127/220 3 60 30/37 98 30/37 98 120/240 3 60 30/37 90 30/37 90 4D8.3 277/480 3 60 30/37 45 30/37 45 220/380* 3 50 25/31 47 25/31 47 230/400 3 50 25/31 45 25/31 45 240/416* 3 50 25/31 43 25/31 43 * 50 Hz models are factory-connected as 230/400 volts.Field-adjustable to 220/380 or 240/416 volts by an authorized service technician. RATINGS:All three-phase units are rated at 0.8 power factor.All single-phase units are rated at 1.0 power factor.Due to manufacturing variations,the ratings tolerance is:t 5%. Standby Ratings:Standby ratings apply to installations served by a reliable utility source.The standby rating is applicable to varying loads with an average load factor of 80%for the duration of a power outage.No overload capacity is specified for this rating.Ratings are in accordance with ISO.3G4611,EIS 5514,AS 2789,and DIN 6271.GENERAL GUIDELINES FOR DERATING:Apifude.Derate 1.31/.per 100 In(328 ft.)elevation above 200 m(656 ft.).Temperature:Derate 3.0%per 101C(18'F)temperature above 25IC(77°F).Availability is subject to change without notice.The generator set manufacturer reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever.Contact your local Kohler generator distributor for availability, G4-229 (30RCL) 4/16 . ' . Data �k �� Application ==~ Cooling RDC2 Controller Radiator System 60 Hz 50 Hz Engine jacket water capacity, 2.65(07) Radiator system capacity,including ' Water pump type Centrifugal Fan diameter,mm(in.) city.n@40mUsV Fan power requirements(powered by engine battery charging alternator) 12VDC.10 amps each `~ Operation Requirements Air Requirements nnx,���� sumz The RDC2 controller provides integrated control for the Radiator-cooled cooling air, generator set, Koh!erm Model RXT transfer switch, m3/min.(mofm)t *1 (1800) 51 (1800) programmable interface module(P|N). and load management. Combustion air,m3/min �hn �8p� �o�� ' ` The RDC2 controller's 2'UneLCD screen displays status Air over engine,m3/nm.kcfm> us(9mV u:(9O0) moaa�geaandoyn�mae�ingu�hataron|�arand000yturoad t Air density~1.00 kg�/»Nu75|bm�» ' Fuel Consumptiont � even in direct sunlight or low light. RDC2 Controller Features .,,~ '^'~ r^-' '~~ � Membrane keypad 75% 9.8 (345) 8.2 (289) 50% 7.6 (268) 6.3 (222) » OFF,AUTO, and RUN push buttons os% uo (196) 4.5 (159) u Select and arrow buttons for access tosystem configuration and adjustment menus LP Gas,m3/hr. Hz 50 Hz o LED indicators for OFF,AUTO.and RUN modes 100% 4.7 (166) 3.9 (138) o LED indicators for utility power and generator set source 75% nJ (132) 3.0 (105) availability and ATS position (Model RXT transfer switch eU% 2.8 (100) u» (81) required) 25% 1.9 (69) 1.6 (56) � LCQoome Exercise 1�u �1) 1�n �� �� o Two lines x10 characters per line t Nominal Fuel R�mn �xm»U ~ ' ' '`~~'~o~~'~' ~`~~` '' » Backlit adjustable for excellent LPvapo�noMJ�3�suu�u�» ' ' visibility inall lighting conditions UP,apnr�omm�ion��o�� 8�8 ft.3=1lb. * Scrolling system status display o.aosmo~I kg. » Generator set status 8U.3wft.»=1gal. o Voltage and frequency » Engine temperature Sound Enclosure Features o Oil pressure w Gnund+aftnnuod - nenclosureuonoocouo1icinou|aUontha\ » Battery voltage meets UL94HF1 flammability classification and repels » Engine runtime hours ' moisture absorption. o Date and time displays * Internally mounted critical silencer. 9 Smart engine oon|dmwn senses engine temperature wSkid'mounted.aluminum construction with two removable * Digital ionchronouo governor to maintain steady-state speed access panels. ak all loads * Fode-.ocoatoh'. and corrosion-resistant Koh/er@cashmere o Digital voltage regulation: ±1.OY& RM8 no-load 0ufull-load powder-baked finish. o Automatic start with programmed cranking cycle Sound Datar Programmable exerciser can be set to start automatically on any future day and timo. andto run every week or every two Model 8ORCL8 point logarithmic average sound levels are weeks 54dB(A) during weekly engine exercise and G1 dB(A) during o Exercise modes full-speed generator diagnostics and normal operation. For n Unloaded exercise with complete system diagnostics comparison!o competitor ratings,the lowest point sound levels o Unloaded full-speed exercise are 52dB(A)and O0dB(A) respectively.^ n Loaded full-speed exercise (Model RXTATSrequired) All sound levels are measured a/7 meters with noload. * Front-access mini USB connector for Site7euh~ connection ° Lowest mo points measured around the generator.Sound levels at other points � |n�aQra| E�herns�oonno�nrforKbh/eraOnOuom p|uo ^munonevomm,may,a�a°»enmnnvnms�x�/vnnumme�o. * Built-in 2.5 amp battery charger o Remote two-wire start/stop capability for optional connection of a Model ROT transfer switch See additional controller features nn the next page. �