Loading...
HomeMy WebLinkAbout18-19705 I/ CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-00k 19705 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL PERMIT INFORMATION . = LOCATION INFORMATION Permit#:19705 Issued: Address: 3060 MOULDEN HOLLOW DR Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 256,391.40 Total Fees: 17,790.47 Subdivision: HIDDEN RIVER Amount Paid: 17,790.47 Date Paid: 5/29/2018 Parcel Number: 24-26-21-0100-00000-0710 CONTRACTOR INFORMATION OWNER INFORMATION Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC Addr: 4600 W. CYPRESS ST STE 200 Address: 4600 W CYPRESS ST STE 200 TAMPA, FL. 33607 TAMPA FL 33607-4099 Phone: (813)574-5743 Lic: Phone: 813-574-5700 Work Desc: CONSTRUCT SINGLE FAMILY 2,276 SQ FT APPLICATION FEES - BUILDING FEE 1,426.49 ELECTRICAL FEE 298.13 PLUMBING FEE 198.75 MECHANICAL FEE 139.13 WATER CONNECTION RESIDENT 1,010.00 SEWER CONNECTION RESIDEW 2,090.00 WATER METER RES 3/4" 473.78 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE NEW 7,128.00 SCHOOL-SFR NEW 1% 71.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32 OT w M Ins ectio,s e uired TOOTER 2ND ROUGH PLUMB MISC INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing, consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. uw�� &-- bve� CONTRACTORS SIGNATURE PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER t813-780-0020 City of Zephyrhilis Permit Application Fax-813-780-0021 Building Department Data Received MAY 0 3 Me Phone Contact for I I Pormittin L 813 363 2891 1 1 1 1 1 1 1 1 r*ir-r 1 11 1 1 1 1 1 A I I I R 1 11NumberA Owner's Name Lennar Homes,LLC Owner Phone 1 813.574.5700 Owner's Address 1 4600 W.Cypress St.Ste.200,Tampa,FL 33607 Owner Phone Number F Fee Simple Titleholder Name I NIA Owner Phone Number L Fee Simple Titleholder Address N/A JOB ADDRESS 13060 Moulden Hollow Drive LOT# 0710 SUBDIVISION Hidden River Phase One A PARCEL I D# 24-26-21-0100-00000-0710 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR ADD/ALT SIGN DEMOLISH P1INSTALL8 REPAIR PROPOSED USE SFR Q COMM OTHER TYPE OF CONSTRUCTION BLOCK Q FRAME 0 STEEL DESCRIPTION OF WORK Single Family Residence/Pool/Screen Enclosure/Fence BUILDING SIZE [T/R SF 2276 7 SQ FOOTAGE1817 HEIGHT 1 Story .0 . . . . . . . . . . . a . . . . . . nxmn . . . . . . . . . . . % 8242 . 54 . . . . . 1BUILDING VALUATION OF TOTAL CONSTRUCTION f ELECTRICAL ���JFX'� PROGRESS ENERGY W.R,E.C. AMP SERVICE PLUMBING $ T�1 MECHANICAL 1$ VALUATION OF MECHANICAL INSTALLATION =GAS 0 ROOFING SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS I FLOOD ZONE AREA DYES Do . . . . . . . 11." 11.4.4..1.4.." 1 a I I I . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....11.4- 7 - - - - - - - - - - - - - - - - - - - - BUILDER COMPANY Lennar Homes,LLC SIGNATURE REGISTERED Y/ N i .FEE CURREN Address 14600 W.Cypkss St.Ste.200,Tampa,FL 33607 1 License#_FEBC1518166 ELECTRICIAN COMPANY Edmonson Electric;-Iris. SIGNATURE REGISTERED Y/ N FEE CURREN E Address 11034 Skip[Ter Road,Tampa, FL 33613 License# FC1 3005408 PLUMBER COMPANY Bayonet Plumbing, Heating &AC, Inc SIGNATURE REGISTERED Y1 N FEE CURREN Y/N Address P.O. Box 5358, Bayonet, FL 34674-5308 License# [CFC042998 MECHANICAL - COMPANY Bayonet Plumbing, Heating &AC SIGNATURE REGISTERED Y1 N FEE CURREN Y/N Address P.O. Box 9308, Bayonet, FL 34674-5308 License# I CAC058062 OTHER COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN K/N Address 14211 Shoalkine Blvd, Spring Hill, FL 34607 License# I CCCO57991 RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans wl Slit Fence Installed, Sanitary Facilities&I dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy.Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpstdr.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ""PROPERTY SURVEY required for all NEW construction. . . . . . . . . . . . . . . . . i. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Directions:_ - - - - --- Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over$7600) Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW . . NOTICE OF DEED The undersigned understands that this permit may be subject to"deed" restrictions" which may ba more restrictive than County regulations. The undersigned assumes responsibility for comp|kahcavvith'ony applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the 'owner has,hired a contractor or contractors to undertake work, fWy may be required to be licensed in accordance with state and local regulations, If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation/�� under state law. If the owner or ir�iended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact, fees are due, they must be paid plior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes,as amended): If valuation of work is $2,500.00 or more, I certify that 1, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner" prior to commencement. CONTRACTOR'SIOWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a '�6rnilt to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of-a permit and that all Work will be performed to meet standards of all laws regulating construction, County and Cit)(codes-,- zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Tnaotmant. - Southwest Florida Water Management Diothct4&e||s, Cypress Bayhaadn, Wetland Aneaa, Altering Watercourses. - Army Corps ofEngineero'Seawa||o. Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-WeUe, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. ' Federal Aviation Authohtv-Flunxvaya. ! understand that the following restrictions apply to the use offill: - Use nƒfill io not allowed |n Flood Zone"\y' unless expressly permitted. - If the fill material is to be used in Flood Zone "/Y', it is understood that m drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by o professional engineer licensed by the State ofFlorida. - If the fill material is to be used in Flood Zone "A. in connection with a permitted building using stem vveU construction, I c6rtify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, | certify that use of such fill will not adversely affect adjacent properties. If-use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit oppUooUon. for \cdo |eno than one (1) acre which are elevated by fill, an engineered drainage plan iorequired. |f| om the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. | understand that e separate permit may be required for electrical vvnrh' p|umWng, signs, vveUo, poo|o, air conditioning. Qoa, or other ineto||edinnn not specifically included in the application. A permit issued ahoU be construed to be license to proceed with the work and not as authority toviolate, oanoe|, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit ioauanoe, or if work authorized by the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension may be nequeatod, in writing, from the Building Official for o period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. |f work ceases for ninety (0O) consecutive days,the job io considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. OWNER-OR AGENT X CONTRACTOR Subscribed and sworn to(or affirnIA)Pefore me this Subscribed and sworn to(or Offirmed)before me this as Identification. as identification. Notary Public Notary Public C_��Commlssion No. No. EliuuM.Holleran DGxuM.Holleran Name of / Notary tvped.minted or stamoed Name of Notary typed,printed or stamped / ' 24-26-21-0100-00000-0710 1 Pasco County Property Appraiser Page 1 of 1 Data Current as Of: Weekly Archive - Saturday, May 12, 2018 Parcel ID 24-26-21-0100-00000-0710 (Card: 001 of 001) Classification 00 - Vacant Residential Mailing Address Property Value LENNAR HOMES LLC Ag Land $0 4600 W CYPRESS ST STE 200 Land $27,540 TAMPA FL 33607-4099 Building $0 Physical Address Extra Features $0 3060 MOULDEN HOLLOW DRIVE ZEPHYRHILLS, FL 33540 Just Value $27,540 Legal Description (First 4 Lines) Assessed (Non-School Amendment 1) $27,540 See Plat for this Subdivision Taxable Value $27,540 HIDDEN RIVER PHASE ONE B PB 76 PG 077 LOT 71 OR 9710 PG 2417 Jurisdiction City of Zephyrhills Land Detail (Card: 001 of 001) Line luse Description Zoning Units Type _Price Condition 'Value 1 0100 SFR MPUD 6,000.00 SF $4.50 1.00 $27,000 2 0100 C SFR T MPUD 600.00 I SF i $0.90 1.00 $540 Additional Land Information �� FEMA Acres 0.15 Tax Area 30ZH Code T____ _TResidential Code HDRVLPI I Building Information - Use 00 - Unimproved (Card: 001 of 001) Unimproved Parcel 00 - Unimproved _ Extra Features (Card: 001 of 001) Line _ Description IYear jUnits IValue No Extra Features Sales History- See All 6 sales Previous Owner: DUNE FL LAND I SUB LLC Month/Year Book/Page Type DOR Code Conditio Amount ount 04/2018 _ 9710 / 2417 Warranty Deed 05�_ Vacant Multi-Parcel Sale_ 09/2011 8606 / 3376 _ Warranty Deed 05 Vacant Multi-Parcel Sale 06/2010 8360 / 1872 Certificate of Title 12 Vacant $0 j http://search.pascopa.com/parcel.aspx?parcel=2126240100000000710 5/116/2018 . 0N�N ��NNN��N�UNNU ` ,�, ' N� UNUUU/NNNU0UN�UNN/N/|0U 2018088731 �p�x � —_-_'- _--_-_ . . C/ zm mM ` IDS: 0.00 IT:' 0 00' 05/29/2028 K. A ' � ' o�ty Clerk --'sC' EI — OR 8N �� a --�� �� ���8 �� of' � � � Permit No. parcel ID No 24-26-21-0100-00000-0710 NOTICE OF COMMENCEMENT state of Florida County of THE UNDERSIGNED notice that improvement will bemade to certain real property,and in accordance with Chapterr13,Florida Statutes, the following information N provided in this Notice ovCommencement: I. Description mProperty: Legal Street Address: SingleFomi| Residence Pool Screen Enclosure Fence u� sennoo|oeuonponno[�mpnmumwm ' u. Owner Information: LennerHmnea LLC, Name 4600,W Cypress St, Ste-200 Tampa FC~�l35U7 Address city mote Interest inProperty: N/A' w�emn�o�p Titleholder: (if other than owner) Address City State 4. Contractor: Lennar�Homes, LLC Name Address city State Telephone No.: 813.574.5700 u Surety: Name Address city State Amount of Bond: Telephone No.: n. Lender: / Name Address city State - Lender's Telephone wo.: 7. Persons within the State of Florida designated by the owner upon whom notices nr other documents may be served as provided by Section 718.|n(1)($FD.Florida Statutes: ' Name ' 4600 W Cypress St, Ste 200 Tampa FL336U7 Address city State Telephone Number of Designated Person: 813.574.5700 ' u m addition m himself,the owner designates m____ to receive a copy of the Lienor's Notice as provided in Section 713.13(l)(b),Florida Statutes. Telephone Number of Person v,Entity Designated byOwner: o. Expiration date vy Notice ofCommencement is one year from the date m recording unless adiffemnt date isspecified: - WARNING TO OWNER: ANY PAYMENTS ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTEDON THE SITE BEFORE THE FIRST INSPECTION, IF YOU INTEND ,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. STATE orFLORIDA COUNTY oFP|NsLU\8 gignature of Owner or Owner's Authorized Officer/Director/Partner/Manager Vice President Signatory's The foregoing Instrument was acknowledged before methis 30 day of March bySteve Robert Smith as Vice President (type of au rity,e.g.,o er,trustee,attorney in fact)for Lennar Homes, LI-C (name of party on eha om instrument was executed). Personally Known E OR Produced Identification El Notary Signo6e-1 Type of Identification Produced Name(Print):fg:sa Holleran Verification pursuantmaeoonou.ou5. FmnduGtamteo. underpena|hmomparjury. |dama,vthat|havomadthe foregoing and that the facts stated in n are true m the best o[my knowledge and belief. L A HO Signature of Natural Person Signing Above Expires June 8,2020 wpdata/bcsmcsmmx Lennar Homes-3060 Moulden Hollow Dr,2,276 sq ft - Column B SQ. FEET PRICE MAIN OR LIVING: 2,276 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 256,391.40 FEE SHEET $ 1,325.00 ADDRESS $ 30.00 DRIVEWAY $ 45.00 BUILDING: $ 1,426.50 ELECTRICAL: $ 298.13 PLUMBING: $ 198.75 MECHANICAL: $ 139.13 SUB-TOTAL $ 2,062.50 TOTAL $ 2,062.50 SEWER: $ 2,090.00 WATER: $ 1,010.00 IRRIGATION: $ - TOTAL: $ 3,100.00 WATER METER: $ 473.78 IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 6,189.63 PARK IMPACT FEES $ 769.56 SIF'S: $ 7,128.00 100.0% $ 7,128.00 1.0% $ 71.28 TOTAL: $ 7,199.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 17,790.47 i ' Lennar Homes-3060 Molden Hollow Dr-2,276 Sgft Column SQ. FEET _ PRICE MAIN OR LIVING: 2,276 $ 112.65 OTHER AREA UNDER ROOF: $ 88.00 OTHER: - $ - VALUATION $ 256,391.40 FEE SHEET $ 1,325.00 ADDRESS $ 40.00 DRIVEWAY $ 40.00 BUILDING: $ 1,431.50 ELECTRICAL: $ 298.13 PLUMBING: $ 198.75 MECHANICAL: $ 139.13 SUB-TOTAL $ 2,067.50 TOTAL $ 2,067.50 SEWER: $ 2,090.00 WATER: $ 1,010.00 IRRIGATION: $ - TOTAL: $ 3,100.00 WATER METER: $ 473.78 IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 6,194.63 PARK IMPACT FEES $ 769.56 SIF'S: $ 7,128.00 100.0% $ 7,128.00 1.0% $ 71.28 TOTAL: $ 7,199.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 17,795.47 PASCO COUNTY, FLORIDA Permit No. _ J1 �_ Date Permitted Builder Name/Owner Name Zex rjaf "Al*ea LLC Control# ' County Parcel No. 2-4-2-&-21-Nob~00di)-07/o SubDiv: AddresstLocation Aicdden OW rr Classification/Type of Use TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: Exempt ❑Yes ❑ No j How Determined Impact Fee Amount $. 3i to 32•o0 Zone No. TAZ: SCHOOL IMPACT FEE Account (056) Single-Family Detached House Amount $ 7, (057). Mobile Home (058) Other Residential 123) Collection Fee Exempt [ Yes ❑ No How Determined PARKS AND RECREATION FEE Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation Total Zone TOTAL AMOUNT $ 70 ' Exempt ❑Yes ❑ No How Determined LIBRARY FEE Land Account Land Credit Land Total r Facility Account Facility Credit Facility Total Exempt ❑ Yes ❑ No How Determined Total Amount RESOURCE FEE' ERU TOTAL-AMOUNT Prepared By Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY Acknowledgement below does not imply acceptance of concurrence,but simply receipt of copy of this form,placing the building permit owner on notice of this assessment and the conditions of payment for same. DATE RECEIVED BY RECEIPT NO. DATE BY psi7VI2 oo'71 PASCO COUNTY DEVELOPMENT SERVICES PASG~ 8731 Citizens Drive Date:7/24/2018 COUNTY FLORWX New Port Richey,FL 34654 tAitw.t`:r,•.� I.S.arra,�, i't 727-847-2411 NOT A PERMIT Receipt#:. 1769804 F E DESCRIPTION ACCOUNT CODE UNITS INVOICE# FEE AMOUNT PAID RECEIPT# JDATE Impact Fee Residential Solid 24503100-329010 34.00 1356526 $34.00 $34.00 1769804 6/20/18 Waste Single Family TOTALS: $34.00 $34.00 Recelot# Paid By Check# CC.Auth# Cashier ID Workstation Receipt Date. Amt Paid 1769804 Check 01006007 545 BCCCP10W 06/20/2018 $34.00 Total Payments: $34.00 Paver Address Phone LENNAR HOMES Comments: SOLID WASTE While you will be paying your bill with Pasco County Development Services,the full amount or the credit card or a checkfees,NOT shown above,Is collected by first Billing payment services_ /A i MyReports/reportsHPASCOPROD/PASCO/RecelptPOS_V6.rpt 7/24/2018 Page 1 of 1 Jacqueline Boges From: TQ Randolph (City of Zephyrhills Support)<support@zephyrhillsfl.zendesk.com> Sent: Thursday, June 7, 2018 4:05 PM To: Jacqueline Boges Subject: [FATHOM] Re: 3060 Moulden hollow.Dr by#19705 ##- Please type your reply above this line -## Your request (#217600) has been solved. TO REOPEN THIS REQUEST, reply to this email or click the link below: https://zephyrhilisfl.zendesk.com/hc/requests/217600 ...................................................................................................................................................................................................................................................................................................................................................................................... TQ Randolph (City of Zephyrhills Support ) '- Jun 7, 1 :04 PM MST Complete 889145-2992659, SO #683467 Best Regards, TQ1 FATHOM Support ..................................................................................................................................................................................................................................................................................................................................................................................... Jacqueline Boges ' --- -' Jun 1, 4:57 AM MST full service 3060 moulden hollow dr�b ) .1�9f7®�5:wsew,e,rawae meter This email is a service from City of Zephyrhills Support . 1 Jacqueline Boges From: City of Zephyrhills Support<support@zephyrhillsfl.zendesk.com> Sent: Friday, June 1, 2018 7:57 AM To: Jacqueline Boges Subject: [Request received] 3060 Moulden hollow Dr by#19705 ##- Please type your reply above this line -## Hello Jacqueline Boges, We are working to resolve your request promptly and will keep you updated. One of our Support Analysts will keep you updated on the progress of your request. Best Regards, FATHOM Support Team TO ADD ADDITIONAL COMMENTS, reply to this email or click the link below: https://zephyrhillsfl.zendesk.com/hc/requests/217600 ....................................................................................................................................................................................................................................................................................................................................................................................... -----I I� Jacqueline Boges Jun 1, 4:57 AM MST full service 3060 moulden hollow dr by#1 9705 water, sewer water meter This email is a service from City of Zephyrhills Support . 1 »gun City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: Date Received: ��— Site: Permit Type: Approved w/no comments:❑ Approved w/the below comments: Denied w/the below comments: ❑ This comment sheet shall be kept with the permit and/or plans. le0fl -z7-,11— P� - GJII-& - Kalvin Swit Plans Examiner Date Contractor and/or Homeowner (Required when comments are present) -single. ami we in Plan Review Comments 1: F.F:E. shall be a minimum of.8" above'the an road eievation. d an engineered site plan. 2.- Lots-shall be graded.to comply with R401.3 of the F.B;C:' 3. ;Compaction_test required if 24" or more of fill dirt is brought in at any.one-place:. . 4:: :Tie irisurveyrequired before pouring concrete.. 5.: Driveways:require a R:O:W. use permit:: All.4:sides of driveway thru the sidewalk shall have expansion material 6.. All.setbacks.'shall be'inet.:. :T. A11 property markers shall be.uricovered and marked.at time of first.'inspection: 8. All A.D.A. requirements.shall be met.: -9. -No electric,plumbing, echanical or framin shall be covered without an inspection.and P g,m. approval 10..All Garages shall,comply with section R302:6.of.the F.B.C:, (Fire Separation).. I.:Appliances-shall'not:be installed in:a locationwhere subjectto m6chanica1damdRe unless. „ rotected b a roved barriers'. M303.4 of the F.B:C P.. - Y. PP . 12. Water heaters shall comply with section:.P607.3 of the F.B.C: 13-. Foundation supports for,A/C.units.shall be raised at least 37 above finished grade. M1308.1 14. Return air in all.:b.edrooms. F.B.C. -MI620.4,; 15. Smoke detectors are.to be installed:in accordance with-R31.3:1 of-the:F.B.C. .16: All glazing requirements are.to be in accordancewithR308.4'of the F.B.C. . 17. All means of egress are to:be in.accordance with R31 1.of the F;B.C. 18. `.`Green gypsum:board shall not be used:as.a backer.jhshowers or tubs.R702.4.2.F.B.C. 19. Combination-type AFCI breakers are required;at all,locations requiring.an AFCI,type breaker: 20. Carbon monoxide.alarms Will be required in.new construction that uses fossil-burning heating or appliances or.an attached garage.- They shall be.installed in accordance with the F,B.C:. 21. All plumbing, mechanical,.and:electrical shall be separate from unit to unit. This includes all . underground plumbing and electric: 22. A11201I N-.E.*C. Codes Will be enforced: . -23.Tamper=Resistant Receptacles in accordance tivith 406:11 of the2011 N.E:C 24.:In accordance.with.the Land.Development:Code; lots shall be,sodded before final at least 10 feet around the structure. 25 A.cony of the energy cads shall be with permitat all times 26.--Cony of final insulation mp6rt shall be.provided with permit before.rnab F.F.E.-Finished Floor.Elevation F.B:C-:Florida Building Code 6t4 Edition- R.O.W.-Right of Way. A.D.A.-Americans with Disabilities Act . N.E.C.-National Electric:Code(2011) 7 .. � �IIM •eiw� !� N� 115 V A nu 6 1474 q' 75 w m r 73 •. y� r ,r a ••'� ''s�,P } �. d IGa *'tom �t CP MAI F EL .44 rim 45 .4o 1 t � yn da w m m °'.. •I/,' :'Y - �,,,"'� 1_u-'S.L 75 FF 46 .,�.� �.,4�'t ,�R Via•^' .r .r'"�� � A f ` �• *.=■ w o r m a FF EL 72.15/ 47 .01 '- EL ! •r m a r e r '_'4'8 4 4- 4 I HE T9t70I7 ..,. FF EL MM +'�'.•.`fit _`-f''.'�i: z:ti �� P s'�.i" � ,r�•''r �t� FFEL 71 71 52 Fr-EL 66 PLOT PLAN SKETCH ONLY NOT A BOUNDARY SURVEY SEC. 24 TWP. 26 S, RNG. 21 E. LOT 71 BEARING BASIS: HIDDEN RIVER PHASE 0 N E B NORTH BOUNDARY OF SUBJECT PLAT BEING S 89'40'43" E PASCO COUNTY, FLORIDA. THIS SURVEY IS SUBJECT. TO ANY FACTS THAT MAY BE DISCLOSED BY A FULL AND ACCURATE ON LOT AREA CALCULATIONS TITLE SEARCH. ALSO SUBJECT TO SETBACKS, LOT =_6600.00—SQ. FT. EASEMENTS AND RESTRICTIONS OF RECORD. LIVING AREA =__1_$38_SQ. FT. ENTRY =__3�L_—SQ. FT. 'r0� UNDERGROUND FOOTER, STEM WALL, AND GARAGE = 406 _SQ. FT. UNDERGROUND UTILITIES ARE NOT LOCATED OR COVERED LANAI =__ __SQ. FT. II SHOWN. PATIO =_ 23 `SQ. FT. DO NOT SCALE THIS PRINT. DIMENSIONS AND CONC. DRIVE =_339 ,SQ. FT. I;i NOTES TAKE PREFERENCE. A/C & CONC PAD =_9___SQ. FT. Q PRIVATE SIDEWALK =--72 SQ. FT. DESCRIPTION NOT CONTAINING PLAT BOOK AND IMPERVIOUS =41 __% PAGE INDICATES THAT PLAT IS IN, = 2719 SQ. FT. t PRELIMINARY STAGE AND IS SUBJECT TO SOD =_3881_SQ. FT. CHANGE AND/OR REVISION. OFF LOT AREA CALCULATIONS CERTAIN DATA SHOWN HEREON BASED ON RIGHT OF WAY =_ 720_00_SQ. FT. ENGINEERING PLANS PROVIDED BY CLIENT. DRIVE APRON = 144 _SQ. FT. STRUCTURE TIES SHOWN HEREON DENOTES PUBLIC SIDEWALK =_ 240 _SQ. FT. MEASUREMENT FROM FORM BOARDS/FOUNDATION SOD =__33_6___SQ. FT. TO PROPERTY LINE. TOTALS * = 10' DRAINAGE/UTILITY EASEMENT AREA =_7320.00 SQ. FT. DRIVEWAY =_483 SQ. FT. SIDEWALK =_-3_12_SQ. FT. SOD =_4217 SQ. FT. PRELIMINARY DRAWING: THIS PLAN IS FOR PERMITTING PURPOSES ONLY, NOT FOR CONSTRUCTION. VERIFY ALL DIMENSIONS BEFORE ANY CONSTRUCTION. LEGEND: f--= PROPOSED DRAINAGE FLOW (00.00) = PROPOSED GRADE E-00.00 = EXISTING GRADE LOT 73 NOTES: LOT GRADING TYPE = A PROPOSED PAD ELEVATION = PRM(P) �" '• FRONT SETBACK = 20' r (Typ) \n SIDE SETBACK = 10' REAR SETBACK = 10' U1 LOT 72 10�0 �cS PLAT 1 o•. ,�• tJLy BOUNDARY 0 51 o° LOT 71 �p AREA \ ry N 0 59,a o n '••o >o, r, O. TRACT "B" HIDDEN RIVER PHASE ONE °� Q' (PLAT BOOK 74, PAGES 101-12 5,�... >o A o`� WETLAND CONSERVATION 2 0 S 20� 0 3 z i\ 0y�9 �>> 0000) 0. Off. e v�� �Q PLAT Cy>oS Q P ° ° o BOUNDARY cP�I n y S J LOT 70 \\ BQUNDARY PROPOSED: LOWEST FLOOR ELEVATIONS: LIVING AREA: 72.50' DESCRIPTION: GARAGE AREA: 71.96' LOT 71, MAP OR PLAT ENTITLED "HIDDEN RIVER PHASE ONE B", ELEVATIONS REFERENCED TO NATIONAL GEODETIC VERTICAL___PAGES THROUGH AS RECORDED IN PLAT BOOK ___, MEAN SEA 29 19 . OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. LEVEL=DATUM OF 19 F. APPARENT FLOOD HAZARD ZONE: 'Y' COMMUNITY PANEL NO. 120230 0460 D EFFECTIVE DATE: 9/30/1992 LEGEND- (C)= CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, q= CENTERLINE, A/C= AIR CONDITIONER, B/C= BACK OF CURB, C/S= CONCRETE SLAB, CH= CHORD, CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= COVERED, E/P= EDGE OF PAVEMENT, ESM'T= EASEMENT, F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE, FIR= FOUND IRON ROD, FN&D= FOUND NAIL & DISK, FPP= FOUND PINCHED PIPE, LFE= LOWEST FLOOR ELEVATION, MAS.= MASONRY, OR= OFFICIAL RECORD BOOK, PB= PLAT BOOK, PCP= PERMANENT CONTROL POINT, PRM= PERMANENT REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & CAP No. 4493, SN&D= SET NAIL & DISK, TBM= TEMPORARY BENCHMARK, U P= UTILITY POLE W F= WOOD FENCE R = RADIAL JOHN R.BEACH&ASSOCIATES,INC. Drawn By: SMS Square Feet: 6600.00 t LENNAR HOMES SURVEYORS AND MAPPERS Checked By: 911 WEST ST. PETERSBURG DRIVE JRB ONE OLDSMAR, FLORIDA 34677 WAY (813) 854-1276 FAX (813) 855-8370 Scale: 1"=30' NOT VALID WITHOUT THE SIGNATURE AND Date of Survey: 9 ZZ — ��aaLpq THE ORIGINAL RAISED SEAL OF A FLOP PLOT PLAN 03/22/2018 RTM 0HN FT. BEACH DATE LICENSED SURVEYOR AND MAPPER FLORIDA R . LAND SURVEYOR No. 2984,) LB 4493 Revisions: J - FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 1791 B1 sf ADS Carrier Builder Name: Lennar Homes Street: 3060 Moulden Hollow Drive Permit Office: Ci iff Ze�hyrhills City,State,Zip: ,FL, Permit Number: /r 0�§ Owner. Lennar Homes Jurisdiction: 611600 Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1572.7 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1241.30 ft2 b.Frame-Wood,Adjacent R=11.0 331.33 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (1817.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1817.00 ft2 6. Conditioned floor area above grade(ft2) 1817 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(143.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 363.4 a. U-Factor: Dbl,U=0.54 87.00 ft2 SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.56 33.33 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 28.4 SEER:15.00 c. U-Factor: Dbl,U=0.56 23.00 ft2 SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 28.2 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 1.233 ft. Area Weighted Average SHGC: 0.308 14.Hot water systems 8. Floor Types (1817.0 sqft.) Insulation Area a.Electric Cap:40 gallons EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1817.00 ft2 b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.079 Total Proposed Modified Loads: 58.31 PASS Total Baseline Loads: 58.15 I hereby certify that the plans and specifications covered by Review of the plans andk[E-ST�r,. this calculation are in compliance with the Florida Energy specifications covered b this P 9Y P Y Code. calculation indicates co liance Dave with the Florida Energy Code. D PREPARED BY: pick Before construction is completed :c� r•, �. DATE: this building will be inspected for compliance with Section 553.908 I hereby certify that this building,as designed, is in compliance Florida Statutes. _ .t with the Florida Energy Code. MAY 0 3 2010 � v wlEr OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.030 Qn for whole house. 5/1/2018 10:10 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 4 FORM R405-2017 ` FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 1791 B1 sf ADS Carrier Builder Name: Lennar Homes Street: 3060 Moulden Hollow Drive Permit office: City of Zephyrhills City,State,Zip: FL, Permit Number: Owner. Lennar Homes Jurisdiction: 611600 Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1572.7 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1241.30 ft2 b.Frame-Wood,Adjacent R=11.0 331.33 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 10.Ceiling Types (1817.0 sqft.) Insulation Area 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1817.00 ft2 6. Conditioned floor area above grade(ft2) 1817 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A - R= ft2 11.Ducts R ft2 7. Windows(143.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 363.4 a. U-Factor: Dbl,U=0.54 87.00 ft2 SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.56 33.33 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 28.4 SEER:15.00 c. U-Factor: Dbl,U=0.56 23.00 ft2 SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 28.2 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 1.233 ft. Area Weighted Average SHGC: 0.308 14.Hot water systems 8. Floor Types (1817.0 sqft.) Insulation Area a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 1817.00 ft2 b. Conservation features EF:0.950 b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.079 Total Proposed Modified Loads: 58.31 PASS Total Baseline Loads: 58.15 I hereby certify that the plans and specifications covered by Review of the plans and 'CSE ST this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. E+' Ilrii.> .•?,,�.`�5,{ PREPARED BY: Dalle AWchBefore construction is completed ` DATE: this building will be inspected for compliance with Section 553.908 I hereby certify that this building,as designed,is in compliance Florida Statutes. with the Florida Energy Code. G'OZj y OWNER/AGENT: MAY O 3 2018 BUILDING FIQIAL: /e!� DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.030 Qn for whole house. 5/1/2018 10:10 AM EnergyGaugeO USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 4 f � FORM R40-5-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 1791131 sf ADS Carrier Builder Name: Lennar Homes Street: 3060 Moulden Hollow Drive Permit office: City of Zephyrhills City,State,Zip: FL, Permit Number: Owner. Lennar Homes Jurisdiction: 611600 Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1572.7 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1241.30 ft2 b.Frame-Wood,Adjacent R=11.0 331.33 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 10.Ceiling Types (1817.0 sgft.) Insulation Area 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1817.00 ft2 6. Conditioned floor area above grade(ft2) 1817 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(143.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 363.4 a. U-Factor: Dbl,U=0.54 87.00 ft2 SHGC: SHGC=0.31 b. U-Factor. Dbl,U=0.56 33.33 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 28.4 SEER:15.00 c. U-Factor: Dbl,U=0.56 23.00 ft2 SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 28.2 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 1.233 ft. Area Weighted Average SHGC: 0.308 14.Hot water systems 8. Floor Types (1817.0 sgft.) Insulation Area a.Electric Cap:40 gallons EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1817.00 ft2 b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.079 Total Proposed Modified Loads: 58.31 PASS w Total Baseline Loads: 58.15 I hereby certify that the plans and specifications covered by Review of the plans and � :T611,t q this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance �aVeG�I�GGt with the Florida Energy Code. PREPARED BY: Before construction is completed DATE: this building will be inspected for "�C-,if, compliance with Section 553.908 I hereby certify that this building,as designed, is in compliance Florida Statutes. " with the Florida Energy Code. G'OD'y MAY 0 3 2018 , OWNER/AGENT: BUILDING OFFI IAL: DATE: DATE: '' - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house. 5/l/2018 10:10 AM EnergyGaugeO USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 4 FORM R405-2017 PROJECT Title: 1791131 sf ADS Carrier Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 1817 Lot# Owner Name: Lennar Homes Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: Lennar Homes Rotate Angle: 45 Street: Permit Office: Cross Ventilation: County: Pasco Jurisdiction: Whole House Fan: City,State,Zip: Family Type: Single-family FL, New/Existing: New(From Plans) Comment: FBC 2017 CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Tampa FL TAMPA_INTERNATI 39 91 70 75 645.5 54 Medium BLOCKS Number Name Area Volume 1 Block1 1817 14536 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1817 14536 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio Main 155 ft 0 1817 ftZ 0.3 0 0.7 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1968 ftZ 0 ftZ Medium 0.85 No 0.9 No 0 22.6 I ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 1817 ftZ N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) Main 30 Blown 1817 ftz 0.11 Wood 5/1/2018 10:10 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 4 FORM R405-2017 WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below# Ornt TO AIV;;11 Type R-Vahle Et In Et In Are;; R-NIAlle Fraction AhSor Grgrie% 1 N=>NE Exterior Concrete Block-Int Insul Main 4.0999 19 6 8 156.0 ft2 0 0.600000 0 _2 N=>NE Garage Frame-Wood Main 11 20 8 8 165.3 ft2 0 0.01 0 3 W=>NW Garage Frame-Wood Main 11 20 9 8 166.0 ft2 0 0.01 0 4 E=>SE Exterior Concrete Block-Int Insul Main 4.0999 58 8 464.0 ft2 0 0.600000 0 5 S=>SW Exterior Concrete Block-Int Insul Main 4.0999 34 8 272.0 ft2 0 0.600000 0 6 W=>NW Exterior Concrete Block-Int Insul Main 4.0999 37 8 8 301.3 ft2 0 0.600000 0 7 S=>SW Exterior Concrete Block-Int Insul Main 4.0999 6 8 48.0 ft2 0 0.600000 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N=>NE Insulated Main None .2 3 6 8 20 ft2 2 N=>NE Wood Main None .4 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered orientation => changed to Worst Case. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N=>NE 1 Metal Low-E Double Yes 0.56 0.28 N 23.0 ft2 1 ft 0 in 4 ft 0 in Drapes/blinds None 2 E=>SE 4 Metal Low-E Double Yes 0.54 0.31 N 32.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds None 3 S=>SW 5 Metal Low-E Double Yes 0.54 0.31 N 32.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds None 4 S=>SW 7 Metal Low-E Double Yes 0.56 0.32 N 33.3 ft2 2 ft 0 in 0 ft 4 in Drapes/blinds None 5 W=>NW 6 Metal Low-E Double Yes 0.54 0.31 N 23.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 427 ft2 427 ft2 42 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1695.9 93.1 175.09' .2669 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ None HSPF:8.5 28.2 kBtu/hr 1 sys#1 5/1/2018 10:10 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 4 FORM R405-2017 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 28.4 kBtu/hr 852 cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 40 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft' DUCTS —Supply— —Return— Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handier TOT OUT QN RLF Heat Cool 1 Attic 6 363.4 ft Main 90.85 ft Proposed Qn Main —cfm 54.5 cfm 0.03 0.60 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Coolin Jan Feb Mar A r Ma X Jun rj Jul Au Se Oct Nov Dec Heating Jan Feb Mar f APr f May f Jun Jul Au �Xj Sep Oct X Nov X Dec Ventin Jan Feb X Mar [X A r [ Ma [ Jun Jul Aug Se [X Oct [X Nov [ Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 i 5/1/201 8 1 0:10 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 4 FORM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerformance Index, the more efficient the home. FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1241.30 ft2 b.Frame-Wood,Adjacent R=11.0 331.33 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types Insulation Area a.Under Attic(Vented) R=30.0 1817.00 ft2 6. Conditioned floor area(ft2) 1817 b.N/A R= ft2 2 7. Windows*' Description Area c. R= ft 11.Ducts R ft2 a. U-Factor: Dbl,U=0.54 87.00 ft2 a.Sup:Attic,Ret:Main,AH:Main 6 363.4 SHGC: SHGC=0.31 b. U-Factor: Dbl, U=0.56 33.33 ft2 SHGC: SHGC=0.32 12.Cooling systems kBtu/hr Efficiency c. U-Factor. Dbl,U=0.56 23.00 ft2 a.Central Unit 28.4 SEER:15.00 SHGC: SHGC=0.28 d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 28.2 HSPF:8.50 Area Weighted Average Overhang Depth: 1.233 ft. Area Weighted Average SHGC: 0.308 8. Floor Types Insulation Area 14.Hot water systems a.Electric Cap:40 gallons ' a.Slab-On-Grade Edge Insulation R=0.0 1817.00 ft2EF:0.95 b.N/A R= ft2 c.N/A R= ft2 b. Conservation features None 15.Credits Pstat certify that this home has complied with the Florida Energy Efficiency Code for Building K .ST` Construction through the above energy saving features which will be installed (or exceeded) o .`.. in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant featur Builder Signature: Date: 05/01/18 �- Address of New Home: 3060 Moulden Hollow Drive City/FL Zip:Ze h rhills, P Y FL 33540 *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 5/1/2018 10:11 AM EnergyGauge®USA-FlaRes2017 -Section R405.4.1 Compliant Software Page 1 of 1 Buildin Anal sis Job: 1791B1 sf ADS g Y Date: 5/1/2018 Entire House By: Dave Bayonet Plumbing Heating and Air Project Information For: Lennar Homes Design C• • • Location: Indoor: Heating Cooling Tampa International AP, FL, US Indoor temperature(OF) 70 75 Elevation: 10 ft Design TD (OF) 39 16 Latitude: 28°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 34.7 54.7 Dry bulb(OF) 31 91 Infiltration: Daily range(OF) - 14 ( L ) Method Simplified Wet bulb(OF) - 77 Construction quality Semi-tight Wind speed(mph) 15.0 7.5 Fireplaces 0 o • Component Btuh/ftz Btuh /° of load Walls 5.6 6529 25.4 °«s Glazing 30.2 4772 18.6 Wall Doors 23.5 466 1.8 nfiltration Ceilings 1.3 2271 8.8 Floors 3.4 6125 23.9 Infiltration 2.2 2887 11.2 Ducts 2616 10.2 Piping 0 0 Glazing Floors Humidification 0 0 Ventilation 0 0 Other Ceilings Adjustments 0 Total 25667 100.0 Component Btuh/ft2 Btuh % of load Walls 2.8 3248 14.7 Walls Internal Gains Glazing 48.7 7697, 34.9 Doors 18.4 365 1.7 Ceilings .1.7 3140 14.2 Floors 0 0 0 Infiltration 0.5 647 2.9 ,, Ducts Ducts 2982 13.5 Ventilation 0 0 Blower Internal gains 3980 18.0 Glazing Infiltration Adjustments 0 Ceilings Total 22057 100.0 Other Latent Cooling Load= 3075 Btuh Overall U-value= 0.104 Btuh/ft2-°F Data entries checked. -Fk-=i-ghtsc ft- 2018-May-01 10:19:42 ^�^•� Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 ..uipment11791 sf ADS template 2.5ton Carrier.rup Calc=MJ8 Front Door faces:SW • Job: 1791B1 sf ADS Project Summary Date: 5/1/2018 Entire House By: Dave Bayonet Plumbing Heating and Air 'Project • • For: Lennar Homes Notes: Design Information Weather: Tampa International AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 31 OF Outside db 91 OF Inside db 70 OF Inside db 75 OF Design TD 39 OF Design TD 16 OF Daily range L Relative humidity 50 % Moisture difference 55 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 23051 Btuh Structure 19075 Btuh Ducts 2616 Btuh Ducts 2982 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh none (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 25667 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 22057 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 2541 Btuh Ducts 534 Btuh Central vent(0 cfm) 0 Btuh Heatingg Coolingg (none) Area 1817 1817 Equipment latent load 3075 Btuh Volumee(ft') 15459 15459 Air changes/hour 0.26 0.14 Equipment Total Load (Sen+Lat) 25133 Btuh Equiv.AVF (cfm). 67 36 Req. total capacity at 0.85 SHR 2.2 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade Trade Model 25HBC53OA00300 Cond 25HBC53OA00300 AHRI ref 9154945 Coil FX4DNF031L AHRI ref 9154945 Efficiency 8.5 HSPF Efficiency 12.5 EER, 15 SEER Heating input Sensible cooling 24140 Btuh Heating output 28200 Btuh @ 47°F Latent cooling 4260 Btuh Temperature rise 26 OF Total cooling 28400 Btuh Actual air flow 1000 cfm Actual air flow 1000 cfm Air flow factor 0.039 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.88 Capacity balance point= 30 OF Backup: n/a n/a Input= 0 kW, Output= 0 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. t - wrigt�tsoft® 2018-May-01 10:19:42 ^�^ a• w• Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 ..uipment11791 sf ADS template 2.5ton Carrier.rup Calc=MJ8 Front Door faces:SW Manual S Compliance Report Job: 1791B1 sf ADS Date: 5/1/2018 Entire House By: Dave Bayonet Plumbing Heating and Air Project Information For: Lennar Homes Cooling Equipment Design Conditions Outdoor design DB: 91.3°F Sensible gain: 22057 Btuh Entering coil DB: 75.7°F Outdoor design WB: 77.3°F Latent gain: 3075 Btuh Entering coil WB: 62.8°F Indoor design DB: 75.0°F Total gain: 25133 Btuh Indoor RH: 50% Estimated airflow: 1000 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: SpIitASHP Manufacturer: Carrier Model: 25HBC530A00300+FX4DNF031L Actual airflow: 1000 cfm Sensible capacity: 24140 Btuh 109% of load Latent capacity: 4260 Btuh 139% of load Total capacity: 28400 Btuh 113% of load SHR: 85% Heating Equipment Design Conditions Outdoor design DB: 30.8°F Heat loss: 25667 Btuh Entering coil DB: 69.6°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: SpIitASHP Manufacturer: Carrier Model: 25HBC530A00300+FX4DNF031L Actual airflow: 1000 cfm Output capacity: 22528 Btuh 88% of load Capacity balance: 30 OF Supplemental heat required: 3139 Btuh Economic balance: -99 OF Backup equipment type: Elec strip Manufacturer: n/a Model: n/a+n/a Actual airflow: 1000 cfm Output capacity: 0 kW 0% of load Temp. rise: 0 OF Meets all requirements of ACCA Manual S. $ WrY9htsoft- 2018-May-0110:19:42 Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 /4CX:;k ...uipment11791 sf ADS template 2.5ton Carrier.rup Calc=MJ8 Front Door faces:SW 5335 - 8TH STREET • (813)780-0020 CERTIFICATE OF OCCUPANCY Address: 3060 MOULDEN HOLLOW DR Owner: LENNAR HOMES LLC ZEPHYRHILLS, FL. 4600 W CYPRESS ST STE 200 Subdiv: HIDDEN RIVER TAMPA FL 33607-4099 Parcel: 24-26-21-0100-00000-0710 Work Type: 101-NEW CONST/SFR Construction Type: NOT APPLICABLE ❑ Sprinklers Use Classification: NOT APPLICABLE Permit Number: 19705 Date: 9/19/2018 _e-62? ISSU BY: BUILDI OFFICIAL : WATER MUST BE CHANGED OVER WITHIN 10 DAYS OF ISSUANCE GARBAGE DEPOSIT MUST BE APPLIED FOR PRIOR TO ISSUANCE