HomeMy WebLinkAbout18-19708 CITY OF ZEPHYRHILLS
5335-STH STREET
(813)780-0020 19708
BUILDING PERMIT SINGLE FAMILY RESIDENTIAL
PERMIT INFORMATION LOCATION INFORMATION -
Permit#:19708 Issued: 5/29/2018 Address: 6500 WAGON TRAIL ST
Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL.
Class of Work: 101-NEW CONST/SFR Township: Range:
Proposed Use: NOT APPLICABLE Lot(s): Block: Section:
Sq. Feet: Est. Value: Book: Page:
Cost: 347,863.20 Total Fees: 11,759.19 Subdivision: SILVERADO
Amount Paid: 11,759.19 Date Paid: 5/29/2018 Parcel Number: 05-26-21-0080-00600-0180
CONTRACTOR INFORMATION OWNER INFORMATION
Name: DR HORTON INC Name: DR HORTON INC
Addr: 12602 TELECOM DR Address: 12602 TELECOM DR
TAMPA, FL. 33637 TAMPA FL 33637-0935
Phone: Lic: Phone: 813-549-1968
Work Desc: CONSTRUCT SINGLE FAMILY 3,088 SQ FT
APPLICATION FEES.
BUILDING FEE 1,336.64 ELECTRICAL FEE 277.20 PLUMBING FEE 184.80
MECHANICAL FEE 129.36 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00
PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE-sfr/100% 4,828.00
SCHOOL IMPACT FEE-sfr/1% 48.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32
�r
G
Inspections Required
FOOTER 2ND ROUGH PLUMB misc INSULATION CEILING
FOOTER BOND DUCTS INSULATED SEWER MISC.
ROUGH ELECTRIC LINTEL MISC MISC.
1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC.
DUCTS INSTALLED WATER MISC DRIVEWAY
PRE-SLAB SHEATHING MISC. MISC.
CONSTRUCTION POLE FRAME MISC. MISC.
REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES:
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing,consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance
with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
CONTRACTORS SIGNATURE PERMIT OFFI
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIOlf
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
813-780-0020 City of Zephyrh ills,Permit Application Fax=als-Tao 0021
Building Department
Date Recelved `r � --
Phone Contact for Permitting
Owner's Naive c? c� r- - Owner Phone Number Ll
Owner's Address ��le � `rn' �'� Tc/b^f�1�J� Owner Phon9 Number
Fee Simple Titleholder Name r Owner Phone Number
Fee Simple Titleholder Address JOB ADDRESS• t� S - LOT# UK�
SUBDIVISION ! V PARCEL ID# t•�
(OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED NEw caNSTR ADDJAL-T SiGN �] [`] DEMOLISH
8 INSTALL. REPAIR
PROPOSED USE F-9 - SFR COMM OTHER
TYPE OF CONSTRUCTION " �°'r BLOCK 0 FRAME i ' STEEL 0
DESCRIPTION OF WORK
BUILDING SIZE — SQ FOOTAGE HEIGHT �_-
t-1-r-11-7 -rrr...s-rl-r-r•1~-e-r-r-T'^P-Q'-r-t-r-rrQ'1t- 'Y? r' �e�R--¢-t-R-it-r-a'
=BUI.LDING VALUATION OF TOTAL CONSTRUCTION
=ELECTRICAL r$, AMP SERVICE PROGRESS ENERGY W.R.E.C.
. PLUMBING
L- - l
MECHANI�CAL $ VALUATION OF MECHANICAL INSTALLATION
. . • as •
=GAS 0 ROOFING SPECIALTY 0 OTHER
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO
'-1{-4-i-1-@-1-i-i-C--i--D-{-i-C--C--i- -➢-i-i--➢•-8-➢-`�-p-B--F�➢=a-C--B-3-E-1-- - -*-G-e-'1--G-c-r-i 6-E-1`�` ➢-- -i-D-i-�'➢-8 m5mp,-s-'9--i- --G-f-@-
BUILDER , i_ COMPANY
SIGNATURE REGISTERED Y/ N FEE CURREN Y(N
Address fo�to c�;l l l�"C .mi i^ J�i�� License# 5 �
..F-LECTRICIAV ,�- COMPANY ��" ����• � r` ��
SIGNATURE �! a,r l REGISTERED Y/ N FEE CURREN Y/N
Address 0�' T ��=l r ! G°� ,�V � °7' •I License
PLUMBER � COMPANY
SIGNATURE REGISTERED Y/ N FEE CURREN Y/N
Address License#
MECHANICAL COMPANY A�i �r*1� iod , 14'r
SIGNATURE f, �^�G�' -- =- --
_ R
E
GISTERED W`i N FEE CURREN Y/N
Address ` ��� li� ,s � ry License#
I n�kG'
OTHERr �. - -- COMPANY
SIGNATURE- / REGISTERED Y/ N FEE CURREN Y/N
Address �� �.,�r'r �?� /�1 License# y
i1lilllli" iiliililliiiiiililtiilil ➢ ➢ ➢ ➢ ➢ Ilillii ! l ➢ 11 •➢ ➢ ! @ !.@ ➢ @1@@ ➢ @ ➢ ➢ ➢ @ •
RESIDENTIAL Attach (2) Plot Plane-, (2)sets of Building Plans; (1)set of Energy Forms; R-O-W Permit.for new construction,
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Siit.Fence installed,
Sanitary Facilities&1 dumpster,Site Work'Permit for subdivisions/large projects
COMMERCIAL" Attach (2)complete sets of Building Plans plus a Life Safety Page, (1)set of Energy Forms, R-O-W•Permit for new construction.
Minimum ten (10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial-requirements must meet compliance
SiGN PERMIT Attach (2)sets of Engineered Plans.
"PROPERTY•SURVEY required for all NEW construction.
.ire cti s-+.-1-„�- -i--a-.a_I-1--1.-}-�-�•-G-8-G-1-Q-B_i-.p-.6-6.�.-aS->�•s-A_G--➢-i-6-•➢--@-➢-@-.@_.@-8--@-➢-a- -➢- ..�-t &.At-E:@�@.a l.-i-@ ➢e6-.➢e-�-t .,
dilrections:
FIJI out application completeiy.
Owner$ Contractor sign back of application,notarized
If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500)
* Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized fetter from owner authorizing same
)VER THE COUNTER PERMITTING (copy of contract required)
leroofs•!f shingles Sewers " Service Upgrades A/C Fences(Plot/Survey/Footage)
Driveways-Not over Counter if on public roadways..needs ROW . .
`
`
�
NOTICE OF DEED RESTRICTIONS: The undersigned undaratundsdlstthkapermitmaybesub�utto "���a" ^ �boDx�
which n�aybe more ranhiot�8than County regu|a�ons. The undersigned assumes `-. r -'---�n-~~~~
applicable deed reutdctions. responsibility compliance with any' '
UNLICENSED CONTRACTORS AND CONTRACTOR RE8PON8| 3lUT/ES. If owner has hired � c on�a�Vror
oon�uotonetounde�ake work, they may be required tobe |ioenaedin accordance with state and local regulations.
Ifthe
contractor is not-licensed as required by |uw, both the owner and contractor may be cited fora misdemeanor violation
under state law. If the owner or intended-contractor are uncertain as to what licensing requirements may apply for the
intended vvork, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at727-847- �
' 8000. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the oontroctor6m\ sign'
portions of the "contractor B|nck" of this application» for which they Will be responsible. If you, as the owner a|g` 'a th�
contractor, that may be an indication that he is notproper(y ||oensod and is not entitled to permitting privileges.in Pasco
County. '
TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE DECO\/ERYFEES: The undersigned.understands
that Transportation Impact Fees and Recourse Recovery Fees may apply tothe uonstnuot|on of new bul|d|nga, change of
use in existing bui|dings, or expansion of existing buiN|ngs, as specified in Pasco County Ordinance number 89407 and
90'07. as amended. The undersigned also.understands, that such feaa, as may be due' will be,identified afthe time of
permitting. It is further understood that Transportation impact Fees and Resource Recovery Feeo. mustba paid prior to
receiving a ^oertUhoete of occupancy" or final power release. If the project does not involve a certificate of occupancy or
final power re|ease, the fees must be paid prior to permit issuance. Furthermore, if Pasco-County Water/Sewer Impact
fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation ufvVnrk is $2.500.08 or more,
\
certify that |, the applicant, have been provided with a copy of the "FloridaConstruction, LienLaw—Homeowner's
Protection Guide" prepared by the Florida Oepodnlant ofAghobbure.and Consumer Affairs. If the applicant is someone '
other �ihanthe "u�n� . ) Pe�Kythat | hcunsobt�nedauopyoftheabovedesmibeddocumentandpronn|sa |ngnodfa�hto
deUveritto the''ovvner' prior tocommencement.
CONTRACTOR'S/OWNER'S AFFIDAVIT: | certify that all the information in this application is accurate and that all work
will be done in compliance with all applicable laws regulating oonstruction, zoning and. land development. Application is �
hereby made to obtain a permit to do.work and installation as indicated. | certify that no work or installation has
commenced prior to issuance of a permit and that all work will be performed to most standards of all laws regulating
construction, County and City codes, zoning regu\eduna, eind'(ond development regulations.in the jurisdiction. \ also
certifvthat | unde�dond that the regulations of'othe� governrnentag�ndasnnay apply to the intended xvork. andthat lt \s
�nyr'apnna|bU|tyto |Uent�v what actions | mUst�take tDba |nuonnpUanca. Such agencies include but are not Unl�ed�t
' Department of- EUv|[onrnont8| Protectiop'{}ypreoa Boyheads. Wetland Areas and Environmentally Sensitive `
Lands,Water/Wastewater Treatment.
- Southwest Florida Water Management 0ntriot4Na|\o. Cypress. Bayheads, Wetland Areas. Altering
VVu1e/uounaos. .
- Army Corps ufEng\neers-SeewaUa. Docks, Navigable Waterways. '
' - Department of Health & Rehabilitative Services/Environmental Health Unh-VVe||n, Wastewater Treatment'
Septic Tanks, `
- US1Environ mental Protection AQenoy'AsbeAtoaabatement.
- Federal Aviation Authohty-Runweye.
\ understand that the following restrictions apply to the use mffill:
- Use of fill is not allowed in Flood Zone "V" unless expressly permitted.
- If the fill material is to be used in Flood Zone ''A'. it is understood that a drainage plan addressing a
' ''connpnnnet|nO volume" will be submitted at time of permitting which is prepared by u prpfeab|mna| ong|nae'r `
licensed by the State ofFlorida.
- If the fill nnataha| is to be used in Flood. Zone ^A" in connection with a.permitted building using stem wall
construction, I certify that fill will be used only to fill the area within the stem wall.
- If fill material is to be used in any area, | certify that use of such fill will not adversely affect adjacent
properties, If use of fill is found to adversely affect adjacent properties, the owner may lqe cited for violating
' the conditions of the building permit issued under the attached permit application, fo[ lots |oae than one U\
acre which are elevated by fill, an engineered drainage plan iarequired.
'If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in
this affidavit prior to commencing construction., | understand that a separate permit may be.required for ekyothoa| work,
p/umbing, eiUno' we||s, poo\a, air nondition|ng, gaa.,or other installations not specifically included in the application. /\
permit issued shall be oonot�uad to be a license to proceed with-the work and not as authority to violate, omnoe|' alter, or
set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter
requiring a correction oferrora,in p|eno, construction or violations of any codes. Every permit issued shall become invalid
unless the work authorized by such permit is commenced within nix months of permit \asuanoe, or if work authorized by
the permit is suspended or abandoned for mper(od^of six (S) months a�ar the�nnethe wiorkiaoornnnenced. An extension
may be requested, in writing', from the Building Official for a period not to exceed ninety (SO) daO and will demonstrate
� justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered abandoned.
'
`
W8\RN|0Q TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT INYOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. }F YOU}0TE0DTO OBTAIN F}N8K\C)0G, CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE �
,LO".""^vR°. r`u . .'u� `
OWNER OR AG ENT
CONTRACTOR
Subscribed and sworn_- ,- affirmed)— before me'his
'
Who .emxau,avavmoucem "mommre personallyknown«`me or:as/have
identification.as mvmmuatmn.
.
'
,~ Notary Public Notary,""""
Commmsmn No Commission m
'
'
Name of Notarytyped,printed- stamped _Name-Notary typed,printed_ �stampedNotary Public State of Florida
Michelle Mayes
� -
My Commission GG 057321
DR Horton-6500 Wagon Trail St-3,088 sq ft-
Column
SQ. FEET PRICE
MAIN OR LIVING: 3,088 $ 112.65
OTHER AREA UNDER ROOF: - $ -
OTHER: - $ -
VALUATION $ 347,863.20
FEE SHEET $ 1,232.00
ADDRESS $ 40.00
DRIVEWAY $ 40.00
BUILDING: $ 1,336.64
ELECTRICAL: $ 277.20
PLUMBING: $ 184.80
MECHANICAL: $ 129.36
SUB-TOTAL $ 1,928.00
TOTAL $ 1,928.00
SEWER:
WATER:
IRRIGATION: $ -
TOTAL: $ - NIA
WATER METER: N/A
IRRIGATION METER $ -
FIRE DEPARTMENT FEES
PLANS TOTAL: $ -
INSPECTION TOTAL:
PERMIT TOTAL
TOTAL: $ -
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
FIRE $ 273.00
5% $ 26.35
TOTAL: $ 553.35
SUB-TOTAL $ 2,481.35
PARK IMPACT FEES $ 769.56
SIF'S: $ 4,828.00
100.0% $ 4,828.00
1.0% $ 48.28
TOTAL: $ 4,876.28
T I F'S: $ 3,632.00
99% $ 3,595.68
1% $ 36.32
TOTAL: $ 11,759.19
IL �c��
City of Zephyrhills
BUILDING PLAN REVIEW COMMENTS
Contractor/Homeowner:
Date Received: ( G� c
Site:
Permit Type:
Approved w/no comments:❑ Approved w/the below comments:/f Denied w/the below comments: ❑
�J
1
This comment sheet shall be kept with the permit and/or plans.
Kalvi Swi —Plans Examiner Date Contractor and/or Homeowner _.
(Required when comments are present)
Ing e ami we In
Plan Review Comments
1: F.F:E. shall be-a minirnum:of 87 above.the road elevation and an engineered site plan.
2.. Lots shall be graded to comply with R401.3 of the F.R.C.
3. _Coinpaetion test required if 24" or more o f fill dirt is brought_in.at any one place: .
A.. :Tie in.survey required before pouring concrete.
5.. Driveways,require.a RDM. . use permit:. All 4:sides of driveway thru the sidewalk shall have
expansion material:.
6. All setbacks shall be'met.:'
T. All property:markers shall be uncovered and marked at time of first 'inspection:
.8:: All A.D.A.-requirements shall be met. .
9. No:electric;plumbing,=mechanical,or framing shall be covered without an:inspection and
:approval-first.. .
10. All Garages shall:comply-with-section R302:6.of the:F.B.C:_(Fire Separation).
11. A liances shall not:be installed in:a'location where subject: mechanical darns a unless.
pp.. .. l. . g
protected by approved barriers. M303.4 of the F.B.C.
12. Water heaters shall,comply:with section:P607.3 of the F.B.C:
13.Foundation supports for.A/C.units.shall'be raised-at least 3" above finished grade. M1308.1
14,Rew air-in all bedrooms..F.B.C. M1620.4 : _
15: Smoke detectors are to be installedari accordance:withi R313:1 of the:F.B.C.
16: All glazing requirements are:to be'in accordance with R308.4.of the F.B:C.
. . .
17. All means of egress are to be i .-accordance with R3 I L of the F.B.C. :
18. `.`Green gypsui m.board"-shall not be'-used as a backer in showers or tubs. R702.4.2 F.B.C.
19.-Combination-type AFCI breakers'are.required:at all,locations requiring an AFCI.type breaker.
20: Carbon monoxide alarms will-be required in.new:construction that uses fossil-burning:-heating
or appliances 'ran attached garage:. They shall be.installed'iri accordance'with.the F,B.C:
:..21. All plumbing,mechanical,:and electrical shall be separate from unit,to:unit: This includes all
underground plumbing and electric:
. 22.. All 2011 N.E:C: Codes,Will be enforced:. .
23:,Tamper=Resistant Receptacles in accordance With 406.1 l of the 2011. N:E:C
.24-.Jh accordance.with the Land:.Devel' ment.Code. lots.shall be'sodded before final at least 10
feet.around the structure:
25. A.copy of the enemy cacls shall be with perfnit-at all times.
26. CO of final.insulatioii repo�'t sliatl be provided with.permit-before.fittab .
RRE:-Finished Floor Elevation
F.B.0 Florida Building Code 6'Edition=
R-;D.W-Right.of Way
A.D.A.-Americans with.Disabilities Act . N.E.C.-National Electric Code(2011).
05-26-21-0080-0.0600-0180 1 Pasco County Property Appraiser Page I of I
Data Current a's Of: Weekly Archive - Wednesday, May 16, 2018
Parcel ID 05-26-21-0080-'00600-0180 (Card: 001 of 001)
Classification 00 - Vacant Residential
Mailing Address Property Value
DR HORTON INC Ag Land $0
12602 TELECOM DR Land $3,136
TAMPA FL 33637-0935 Building $0
Physical Address Extra Features $0
6500,WAGON TRAIL STREET
ZEPHYRHILLS, FL,33541 Just Value $.3,136
Legal Description (First 4 Lines) Assessed (Non-School Amendment 1) $3,136
SILVERADO RANCH SUBDIVISION
PHASES 6, 8 &9A PB 75 PG 075 BLOCK 6 Taxable Value $3,136
LOT 18
Jurisdiction
City of Zephyrhills
Land Detail (Card: 001 of 001)
Line Use jDescriptionZong Units ``Type Price-- 1,Condition Value
1 0100 SFR MPUD 6,000.00 SF $0.40 1 1.00 $2,400
1.00 $736
2,94�._0�0 SF 2 0100 SFR MPUD
Additional Land Information
30SI I Code Residential Code SLVRCP1
Acres 1 0.21 ITax Arear FEM"A F_ I
Building Information - Use 00 - Unimproved (Card: 001 of 001)
Unimproved Parcel 00 - Unimproved
Extra Features (Card: 001 of 001)
L ne Description
i __dyear jq!#ts Value
No Extra Features
Sales History- See All 6 sales
Previous Owner: DUNE FL LAND I SUB LLC
Month/Year Book/Page 1Type DOR Code ConditionlAmount
05/2018 9725 1 0407 Warranty Deed Vacant !Multi-Parcel Sale
05/2017 9535 / 0546 Certificate of Title 05 Vacant IMulti-Parcel Sale
11/2016 19462 1 0384 Mineral Rights or Royalty Transfer! 05 Vacant IMulti-Parcel Sale
http://search.pascopa.com/parcel.aspx?parcel=2126050080006000180 5/18/2018
CITY OF / / / / BUILDING
ZEPHYRHILLSNOTICE
DEPARTMENT
OF ADDITION OR CORRECTION
D • NOT - •
AD RESS DATE PERMIT f
THIS JOB HAS NOT BEEN COMPLETED. he following additions or corrections shall be made before the job
will be accepted.
IT
ir
It is unlawful for any Carpenter,Contractor,Builder,or other persons,to AFTER CORRECTIONS ARE MADE CALL
cover or cause to be covered,any part of the work with flooring,lath,earth 780-0020 FOR RE-INSPECTION
or other material,until the proper inspector has had ample time to approve
the installation.
OFFICE HOURS 7:30AM-4:30 PM MON.-FRI. INSPECTOR
INsTFR#2018.Q.84892OR BK!9727 PG3316 Page I Of I
/2018 Rcpt:1958805 Rec:10. DS:0.00 IT:
D, Pasco COunt-y Cr00 erfe&ComytrollCe0-00r
05121
PauCa S.
Permit No. Parcel'ID No
NOTICE OF COMMENCEMENT
State of Florida County of PaS-:0
THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 713,Florida Statutes,
the following information is provided In this Notice of Commencement. f
Ise
Commencement.
I C
1. Description of Property: Parcel Identification No. Ci 17"! ,
Street Address: Ctiir�
—.1-
2. General Description of Improvement New Single Family Residence
3. Owner Information or Lessee information if the Lessee contracted for the improvement
D.R. Horton. InQ
Name
12802 Tp1prom Driva Tampa 33637 Fi
Address City State
Interest in Property: Fee Simple
Name of Fee Simple Titleholder.
(If different from Owner listed above)
Address city I State
4. Contractor. —D—R. Horton. Inc
Name
-12602 Telecom DrIve-- Tnmnn 33637 FL
y,
Address It State
Contractors Telephone No.:
5. Surety: NIA
Name
Address city state
Amount of Bond: $ N/A Telephone No
6. Lender- N/A
Name
Address city State
Lenders Telephone No.:
7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by
Section 713.13(1)(a)(7),Florida Statutes:
David Gude
Name
12602 Telemm Drive Tamna 33637 FL
Address city I state
Telephone Number of Designated Person: 813-740-9720
8. In addition to himself,the owner designates NIA Of
to receive a copy of the Lienoes Notice as provided in Section 713.13(1)(b),Florida Statutes.
Telephone Number of Person or Entity Designated by Owner: I
9. Expiration date of Notice of Commencement(the expiration date may not be before the completion of construction and final payment to the
contractor,but will be one year from the date of recording unless a different date is specified): I
WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT
ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND' CAN
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. ANOTiCE OF COMMENCEMENT MUST BE
RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDINGIYOUR NOTICE OF COMMENCEMENT.
Under penalty of perjury,I declare that I have read the foregoing notice of commencement and at the facts stated therein are true to the best
of my knowledge and belief.
STATE OF FLORIDA -T
COUNTY OF PASCO as&—
Sig(iature of Owner or Lessee,or Owners or Lessee's Authorized
Offiftr/DirectoriPartner/Manager
Assistant Secretand Horton. Inc
Signatory's Title/Office
The foregoing instrument was acknowledged before me this dayof Am,:�: 201 IV
_L by
Is Assistant Secrelay 0 (type of au rity,e-g.,officer,trustee,attorney in fact)for
D.R. Horton. Inc (name of party�on b i alfqf whom instruTdnt was executed).
Personally Known R OR Produced Identification[I Notary Signature--
Type of Identification Produced Name(Print)
0
ii
(type of a ri�,e-.,___ F
7,"Mla 7-te,
Notary Public State of Florida
,00P
4?-(% Michelle Moyes
MY Commission GG 067321
ora Expires 12(21/2020
wpdatafbcstnoticecommencement_pc053048
PASCO COUNTY, FLORIDA
Permit No. 113
Date Permitted
Builder Name/Owner Name Control
County Parcel No. SubDiv: 56-&do
Address/Location cp_soo. roul ls-r
Classification/Type of Use C I 11q te
TRANSPORTATION IMPACT FEE Rate: Sq Ft Unit:
Exempt t] Yes" ❑ No How Determined
Impact Fee Amount .2 3 200 Zone No. TAZ:
SCHOOL IMPACT FEE
Account (056) Single-Family Detached House Amount $ 2,8
(057) Mobile Home
(058) Other Residential
(123) Collection Fee
Exempt []Yes R No How Determined
PARKS AND RECREATION FEE
Land Account Land Credit Land Total
Recreation Account Recreation Credit Recreation Total ll
Zone TOTAL AMOUNT $ :Ad
Exempt f-I Yes F] No How Determined
LIBRARY FEE
Land Account Land Credit Land Total
Facility Account Facility Credit Facility Total
Exempt R Yes ❑ No How Determined Total Amount
RESOURCE FEE ERL1
TOTAL AMOUNT
Prepared By Checked By
-V
NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION
PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE
BEEN PAID AND
RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY
Acknowledgement below does not Imply acceptance of concurrence,but simply receipt of a copy of this form,placing
the building permit owner on notice of this assessment and the conditions of payment for same.
DATE RECEIVED BY
RECEIPT NO. DATE BY
C PASCO COUNTY
DEVELOPMENT SERVICE'S Date:8115/2018
PAS : t�, 8731 Citizens Drive
COUNTY FLORID New Port Richey,FL 34654
727-847-2411
rmOJT A PIPIT :
Receipt#: 1784882
FEE DESCRIPTION ACCOUNT CODE UNITS INVOICE# FEE AMOUNT PAID RECEIPT# DATE
Impact Fee Residential Solid 24503100-329010 23.96 1374735 $23.96 $23.96 1784882 8/15/18
Waste Single Family
TOTALS: $23.96 $23.96
ReceiRt# Paid By Check# CC Auth# Cashier ID Workstation Receipt Date Amt Paid
1784882 Check 791246 540 BCCCP06W 08/1512018 $23.96
Total Payments: $23.96
Pa or Address Phone
D R Horton 1341 Horton Circle
Arlington TX 76011
Comments:
Solid w5 afor City of Ze,hyrhill
Addres :6500 Wagon Trail.,
Parcel: 5 26 210080 e 00 0180
While you will be paying your.b)ll with Pasco County Development Services,the full amount of the credit card or e-check fees,NOT shown above,Is collected by
First filling payment services.
MyReports/reports//PASCOPkOD/PASC0/ReceiptPOS—V6.rpt 8/15/2018 Page 1 of 1
D.R. Horton-6500 Wagon Trail St-'3,088 sq ftj�
Column Es
SQ. FEET PRICE
MAIN OR LIVING: 3,088 $ 112.65
OTHER AREA UNDER ROOF: $ 88.00
OTHER: - $ -
VALUATION $ 347,863.20
FEE SHEET $ 1,232.00
ADDRESS $ 40.00
DRIVEWAY $ 40.00
BUILDING: $ 1,336.64
ELECTRICAL: $ 277.20
PLUMBING: $ 184.80
MECHANICAL: $ 129.36
SUB-TOTAL $ 1,928.00
TOTAL $ 1,928.00
SEWER: n/a
WATER: n/a
IRRIGATION: $ -
TOTAL: $ -
WATER METER: n/a
IRRIGATION METER $ -
FIRE DEPARTMENT FEES
PLANS TOTAL: n/a
INSPECTION TOTAL:
PERMIT TOTAL
TOTAL: $ -
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
FIRE $ 273.00
5% $ 26.35
TOTAL: $ 553.35
SUB-TOTAL $ 2,481.35
PARK IMPACT FEES $ 769.56
SIF'S: $ 4,828.00
100.0% $ 4,828.00
1.0% $ 48.28
TOTAL: $ 4,876.28
T 1 F'S: $ 3,632.00
99% $ 3,595.68
1% $ 36.32
TOTAL: $ 11,759.19
PLOT PLAN
DESCRIPTION:(AS FURNISHED)
LOT 18, BLOCK 6, SILVERADO RANCH SUBDIVISION PHASE 6, 8 & 9A
AS RECORDED IN PLAT BOOK 75, PAGE(S) 75-80, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA.
Curve Table
Curve# Length Radius Delta I Chord Bearing Chard
C1 39.31' 55.OD' 40'57'11- N10'20'36-E 38.48'
_� eP
LOT 17 0°~0 °��
�<Y9 BLOCK 6 �°/6
os
q�co,O� N79
.52 p1 E — — o can a�
qy Fy'r 52•p1•E ( 'o'..
rR 't'S RP___ N755.00 I 30.8' I N yD.
LU
Reed�Y +'Ybhb o I I16. 0 36.7' 45.7' mrn
R/')'CJ `� I •-' I o'::" / ;fir o �/
00
toe
/ m 16 O O�
ON LOT CALCULATIONS / ry\ 40 7, o :V OI
LOT = 8,946 SO. FT. / w a
LIVING AREA = 1,104 SQ. FT. / \
GARAGE = 437 SO. FT. /
ENTRY = 53 SQ. FT.
LANAI = 0 SO. FT.
PATIO = 80 SQ. FT. q�/q /St //,,• \\ y
DRIVEWAY = 410 SQ. FT.
/ Q
A/C PAD = 12 SQ. FT. /
WALKWAY = 30 SQ. FT.
IMPERVIOUS = 24% JJ \ / O •'��
= 2126 SQ. FT. J
820 SQ. FT. <oc"j-/9 S0 40 �Q�
OFF LOT CALCULATIONS ���
RIGHT OF WAY = 258 SO. FT. 6 ��o= pZ
DRIVE APRON. = 39 SO. FT. o /
PUBLIC S/W = 188 SQ. FT. / r9
SOD = 31 SQ. FT. /• ,`Po�r-0
TOTALS
AREA = 9,204 SQ. FT.
DRIVEWAY = 449 SO. FT.
SIDEWALK = 218 SQ. FT. �
SOD = 6,851 SQ. FT.
a
Q�
PREPARED FOR: w
o
(1 R•HOKMN 1'•'= 30'
GRAPHIC SCALE
0 15 30
BUILDING SETBACKS
FRONT: 22'
REAR: 15'
SIDE: 7.5'
SIDE STREET: 20'
LEGEND:
NOTES: BUILDING SETBACK LINE PI POINT OF INTERSECTION "
1. ELEVATIONS SHOWN ARE PER LOT GRADING PC POINT OF CURVATURE
PLANS-PROVIDED BY THE CLIENT. - CENTERLINE PT POINT OF TANGENCY
2. ELEVATIONS ARE BASED ON NAVD 1988 — - - — RIGHT OF WAY LINE RP RADIUS POINT
PRC POINT OF REVERSE CURVATURE
DATUM. PROPOSED ELEVATION PCC POINT OF COMPOUND CURVATURE
TYP TYPICAL
THIS PLOT PLAN IS INTENDED FOR PERMITTING PURPOSES PROPOSED DRAINAGE FLOW CS CONCRETE SLAB
ONLY. THIS IS NOT INTENDED FOR THE CONSTRUCTION OF (P) PER PLAT
THE PROPOSED HOUSE. REFER TO HOUSE PLAN AND CONCRETE (C) CALCULATED
OPTION LIST FOR CONSTRUCTION. ALL BUILDING SET BACK A/C AIR CONDITIONER PB PLAT BOOK
LINES SHOWN HEREON IS PER DATA FURNISHED BY CLIENT S/W SIDEWALK PGS PAGES
SO. FT. SQUARE FEET
AND IS FOR INFORMATIONAL PURPOSES ONLY. F.E.M.A. FEDERAL EMERGENCY MANAGEMENT AGENCY
F.I.R.M. FLOOD RATE MAP
THIS IS NOT A SURVEY NAVD NORTH IAMERICANE VERTICAL DATUM
NOVO NATIONAL GEODETIC VERTICAL DATUM
THIS IS A PLOT PLAN ONLY D&UE DRAINAGE&UTILITY EASEMENT
PDE PRIVATE DRAINAGE EASEMENT
FLOOD NOTE: LIE UTILITY EASEMENT(PUBLIC)
I HAVE EXAMINED THE F.I.R.M. MAP NO. 12101CO288F, SURVEYOR NOTES:
DATED SEPTEMBER 26. 2014. AND FOUND THE SUBJECT PROPERTY 1. THE SURVEYOR HAS NOT ABSTRACTED THE
APPEARS TO LIE IN ZONE -X-. AREAS OUTSIDE THE 100 YEAR ND SHOWN HEREON FOR EASEMENTS, RIGHT
FLOODPLAIN AND ZONE'A-, AREAS DETERMINED TO BE SPECIAL FLOOD LOF AND
WAY, RESTRICTIONS OF RECORD WHICH
HAZARD AREAS SUBJECT TO INUNDATION BY THE 1%ANNUAL CHANCE MAY AFFECT THE TITLE OR USE OF THE LAND.
FLOOD EVENT. THE SURVEYOR MAKES NO GUARANTEES AS TO THE
ABOVE INFORMATION. PLEASE CONTACT THE LOCAL F.E.M.A. AGENT FOR VERIFICATION. 2. NO UNDERGROUND IMPROVEMENTS HAVE BEEN
LOCATED EXCEPT AS SHOWN.
BEARING BASIS:
BEARINGS SHOWN HEREON ARE BASED ON THE CENTERLINE OF WAGON A5hA 3. NOT VALID WITHOUT THE AUTHENTIC
TRAIL STREET BEING N53.35'22-W, PER PLAT. ELECTRONIC SIGNATURE AND THE AUTHENTIC
A M E FR 1 CAN ELECTRONIC SEAL OF A FLORIDA LICENSED
(FIELD DATE:) REVISED: ` ' , �/ SURVEYOR AND MAPPER:
SU R V C 7 1 N m Dlgitallysignedby.l.—W
SCALE: 1' = 30 FEET .y' ".;ee �Boleman
8c MAPPING INC. " �
_ 3 2i='°•• .:DN:cn=lames W Boleman,
APPROVED BY: J13 �`"' aes o American Surveying&Mapping,
CERTIFICATION OF AUTHORIZATION NUMBER LB//6393 15 + '•j4�_�_`ou,
171013 LOT 18. BLK 6 3191 MAGUIRE BOULEVARD, SUITE 200 �¢'e ;;�a:;;'°:"'° _...,email=)buleman�asmcorporate.m FOR
JOB NO. ORLANDO, FLORIDA 32803 em"�amiim" m,c=US THE
` Date:2017.11.160412:30-05'OD'
(407) 426-7979
DRAWN BY: DSB PLOT PLAN 11 1D 17 KJW WWW.AMERICANSURVEYINGANDMAPPING.COM JAMES W. BOLEMAN PSM# 6485 DATE
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Envelope Leakage Test Report
Prescriptive and Performance Method
Project Name: SILVERADO Builder Name: D R HORTON
Street: 6500 Wagon Trail St Permit Office:
City,State,Zip: Zephyrhills,FL 33541 Permit Number:
Design Location: 6500 Wagon Trail St(Lot 18) Jurisdiction:
Cond.Floor Area: 2354 Cond.Volume: 20618
Envelope Leakage Test Results Leakage Characteristics
Regression Data:
C: n: R:
CFM(50): 2354
Single or Multi Point Test Data
ELA: 129
HOUSE PRESSURE FLOW:
1 50 Pa 2354 cfm EgLA: 306
ACH: 6.85
2 0 Pa 0 cfm
SLA: .06
3 0 Pa 0 cfm
ACH(50)*: 6.85
4 0 Pa 0 cfm
*For prescriptive projects,tested leakage must be<=7
5 0 Pa 0 cfm ACH(50). For performance projects, tested leakage
must be<=the ACH(50)shown on Form R405-2014
6 Pa cfm for this project.
R402.4.1.2 Testing.The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zones 1
and 2.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Testing shall be conducted by either individuals as defined in
Section 553.993(5)or(7),Florida Statutes or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party.A written report of the
results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all
penetrations of the building thermal envelope.
During testing:
1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other
2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration
3.Interior doors,if installed at the time of the test,shall be open;
4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed;
5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and
6.Supply and return registers,if installed at the time of the test,shall be fully open.
I hereby certify that the above envelope leakage performance results
demonstrate compliance with Florida Energy Code requirements in
accordance with Section R402.4.1.2.
Testing shall be conducted by either individuals as
defined in Section 553.993(5)or(7), Florida Statutes p4TF1E5T1iC
or individuals licensed as set forth in Section
3( )(f),(g),or(i)or an approved third party.A ' ,`
489.105
written report of the results of the test shall be signed u3
Digitally signed by Michael by the third party conducting the test and provided to -{ill
IE{
Silberstein the code official. * k
Date:2018.09.19 20:04:43 EDT
CN=Michael Silberstein,O=TopBuild
Home Services,OU, �'Op we t9J
EMAI LADDRESS=Mich ael.Silb erste i
Signature: n@topbuild.com,C=US
Printed Name:
Michael Silberstein BUILDING OFFI AL:
Date: 09/19/2018 DATE: G
Thank you for allowing TopBuild the opportunity to provide the above services for you.Please feel free to contact me with any questions.
1 0/2 512 01 7
399340
CITY OF " NOTICE "
/ / BUILDING
ZEPHYRHIL.LS DEPARTMENT
OF ADDITION OR CORRECTION
D • NOT - •
ADDRESS DATE PERMIT
JC
_ l �o�
THIS JOB HAS NOT BEEN COMPLETED.4.The following additions or corrections shall be made before the job
will be accepted.
Lo
It is unlawful for any Carpenter,Contractor,Builder,or other persons,to AFTER CORRECTIONS ARE MADE CALL
cover or cause to be covered,any part of the work with flooring,lath,earth 7g0-0020 FOR RE-INSPECTION
or other material,until the proper inspector has had ample time to approve
the installation.
INSPECTOR
OFFICE HOURS 7:30AM-4:30 PM MON-FRI.
5335 - 8TH STREET
(813)780-0020
CERTIFICATE OF OCCUPANCY
Address: 6500 WAGON TRAIL ST Owner: DR HORTON INC
ZEPHYRHILLS, FL. 12602 TELECOM DR
Subdiv: SILVERADO TAMPA FL 33637-0935
Parcel: 05-26-21-0080-00600-0180 Work Type: 101-NEW CONST/SFR
Construction Type: NOT APPLICABLE ❑ Sprinklers
Use Classification: NOT APPLICABLE
Permit Number: 19708
Date- 9/24/2018
v ;
tbpv�
ISSUED Y: BUILDI OFFICIAL :
WATER MUST BE CHANGED OVER WITHIN 10 DAYS OF ISSUANCE
GARBAGE DEPOSIT MUST BE APPLIED FOR PRIOR TO ISSUANCE
FORM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: /Hayden 2605 Elev C i _/_ Builder Name: DRH Expryss Homes
Street: lD IJ �>dn�r�?i u / Permit Office: ` 7R_Pn ("(
City,State,Zip: Zephyrhills, FL, Permit Number: 14
1 6
Owner: M50 Jurisdiction: (D-tt(pab
Design Location: FL,Tampa \ County:: Pasco(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(2614.2 sgft.) Insulation Area
2. Single family or multiple family Single-family a. Frame-Wood, Exterior R=11.0 1285.30 ft2
b.Concrete Block-Int Insul, Exterior R=4.1 996.67 ft2
3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 332.22 ft2
4. Number of Bedrooms 5 d.N/A R= ft2
10.Ceiling Types (1541.0 sqft.) Insulation Area
5. Is this a worst case? No a.Under Attic(Vented) R=30.0 1541.00 ft2
6. Conditioned floor area above grade(ft2) 2605 b.N/A R= ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ft2
11. Ducts R ft2
7. Windows(250.0 sgft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 261
a. U-Factor: Dbl,U=0.34 210.00 ft2
SHGC: SHGC=0.31
b. U-Factor: Dbl,U=0.55 40.00 ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.34 a.Central Unit 40.0 .SEER:14.00
c. U-Factor: N/A ft2
SHGC: 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a.Electric Heat Pump 41.0 HSPF:8.20
SHGC:
Area Weighted Average Overhang Depth: 1.052 ft.
Area Weighted Average SHGC: 0.315 14.Hot water systems
8. Floor Types (1541.0 sg a.Electric Cap:50 gallons
ft.) Insulation Area EF:0.950
a.Slab-On-Grade Edge Insulation R=0.0 1104.00 ft2 b. Conservation features
b.Raised Floor R=19.0 437.00 ft2 None
c.N/A R= ft2 - 15.Credits Pstat
Glass/Floor Area: 0.096 F��7CS
Total Proposed Modified Loads: 78.39 PASS
Total Baseline Loads: 79.15
1 hereby certify that the plans and specifications covered by Review of the plans and J'V14E ST,gx
this calculation are in compliance with the Florida Energy specifications covered by this `_ p
Code. calculation indicates compliance
with the Florida Energy Code. N rrr„ ::: ;;\•° „
PREPARED BY: Before construction is completed u�3
DATE: n-g-n this buildingwill be inspected for
a
P c➢ r°l; �►
compliance with Section 553.908 * °
I hereby certify that this building, as designed, is in compliance Florida Statutes.
with the Florida Energy Code. �i flD yyT,'�
OWNER/AGENT:� BUILDING OFFICIAJ�: !/
DATE: / �V DATE: _(" �S'l
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.2.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
test report in accordance with R402.4.1.2.
- Compliance with a proposed duct leakage On requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with Section 803 of RESNET Standards, is not greater than 0.050 On for whole house.
1 1/9/201 7 9:57 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5
FORM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Hayden 2605 Elev C Builder Name: DRH Express Homes
Street: 6_ Permit Office:
City,State,Zip: Zephyrhills,FL I k
Permit Number:
Owner: 4 Jurisdiction:
Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2
i New construction or existing New(From Plans) 9. Wall Types(2614.2 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=1 1.0 1285.30 ft2'
-b.Concrete Block-Int Insul,Exterior R=4.1 996.67 ft2
3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=1 1.0 332.22 ft2
4. Number of Bedrooms 5 d.N/A R= ft2
10.Ceiling Types (1541.0 sqft.) Insulation Area "
5. Is this a worst case? No a.Under Attic(Vented) R=30.0 1541.00 ft2
6. Conditioned floor area above grade(ft2) 2605 b.N/A R= ft2
N/A
Conditioned floor area below grade(ft2) 0 c.11. Duct R= ft2
s R ft2
7. Windows(250.0 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 261
a. U-Factor: Dbl,U=0.34 210.00 ft2
SHGC: SHGC=0.31 12.Cooling systems kBtu/hr Efficiency
b. U-Factor: Dbl,U=0.55 40.00 ft2 SHGC: SHGC=0.34 a.Central unit 40.0 SEER:14.00
c. U-Factor: N/A ft2
SHGC: 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a.Electric Heat Pump 41.0 HSPF:8.20
SHGC:
Area Weighted Average Overhang Depth: 1.052 ft.
Area Weighted Average SHGC: 0.315 14.Hot water systems
8, Floor Types (1541.0 sqft.) Insulation Area a.Electric Cap:50 gallons
a.Slab-On-Grade Ed EF:0.950
ge Insulation R=0.0 1104.00 ft2 b. Conservation features
b.Raised Floor 11=19.0 437.00 ft2 None
c.N/A R= ft2 15.Credits Pstat
Glass/Floor Area: 0,096 Total Proposed Modified Loads: 78.39 PASS
Total Baseline Loads: 79.15
0
I hereby certify that the plans and specifications covered by Review of the plans and
this calculation are in compliance with the Florida Energy specifications covered by this
Code. calculation indicates compliance 'o
with the Florida Energy Code. 0
PREPARED BY: 4 Before construction is completed
DATE: this building will be inspected for 0 7 P41-
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance Florida Statutes.
with the Florida Energy Code. WE
OWNER/AGENT- f���L.��T��-- BUILDING PFFI IAL:
DATE: DATE: 4�
- Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as
certified factory-sealed in accordance with R403.2.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
test report in accordance with R402.4.1.2. I
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with Section 803 of RESNET Standards, is riot greater than 0.050 Qn for whole house.
11/9/2017 9:57 AM EnergyGauge(D USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5
FORM R405-2014
PROJECT
Title: Hayden 2605 Elev C Bedrooms: 5 Address Type: Lot Information
Building Type: User Conditioned Area: 2605 Lot# 18/6
Owner: Total Stories: 2 Block/Su bDivision: Silverado Ranch
#of Units: 1 Worst Case: No PlatBook:
Builder Name: DRH Express Homes Rotate Angle: 270 Street:
Permit Office: Cross Ventilation: County: Pasco
Jurisdiction: Whole House Fan: City,State,Zip: Zephyrhills,
Family Type: Single-family FL;
New/Existing: New(From Plans)
Comment: Garage R Face W
CLIMATE
IECC Design Temp Int Design Temp Heating Design Daily Temp
Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,Tampa FL_TAMPA_INTERNATI 2 39 91 70 75 - 645.5 54 Medium
BLOCKS
Number Name Area Volume
1 Blocki 2605 21579.7
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
1 Main 1104 9571.7 Yes 1 1 1 Yes Yes Yes
2 2nd Floor 1501 12008 No 5 4 1 Yes Yes Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio Main 152.8 ft 0 1104 ftz ---- 0.2 0 0.8
2 Raised Floor 2nd Floor ---- ---- 437 ft2 19 0.5 0 0.5
ROOF
/ Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
1 Hip Composition shingles 1723 ftz 0 ftz Dark 0.92 No 0.9 No 0 26.6
ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Vented 300 1541 ftz Y N
1 1/9/201 7 9:57 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5
FORM R405-2014
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Vented) Main 30 Blown 40 ft2 0.11 Wood
2 Under Attic(Vented) 2nd Floor 30 Blown 1501 ft2 0.11 Wood
WALLS
Adjacent r Space Cavity Width Height Sheathing Framing Solar Below
In Wall lype
1 N=>W Exterior Concrete Block-Int Insul Main 4.1 18 8 8 8 161.8 ft2 0 0.6 0
2 W=>S Exterior Concrete Block-Int Insul Main 4.1 20 8 8 173.3 ft2 0 0.6 0
3 S=>E Exterior Concrete Block-Int Insul Main 4.1 39 8 8 8 343.8 ft2 0 0.6 0
4 E=>N Exterior Concrete Block-Int Insul Main 4.1 36 8 8 8 317.8 ft2 0 0.6 0
5 N=>W Garage Frame-Wood Main 11 20 4 8 8 176.2 ft2 0.23 0.01 0
6 W=>S Garage Frame-Wood Main 11 18 0 8 8 156.0 ft2 0.23 0.01 0
7 N=>W Exterior Frame-Wood 2nd Floor 11 39 8 8 317.3 ft2 0.23 0.6 0
8 W=>S Exterior Frame-Wood 2nd Floor 11 40 8 8 325.3 ft2 0.23 0.6 0
9 S=>E Exterior Frame-Wood 2nd Floor 11 39 8 8 317.3 ft2 0.23 0.6 0
10 E=>N Exterior Frame-Wood 2nd Floor 11 40 8 8 325.3 ft? 0.23 0.6 0
DOORS
# Ornt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 N=>W Insulated Main None .4 3 6 8 20 ft2
2 N=>W Wood Main None .46 2 8 6 8 17.8 ft2
WINDOWS
Orientation shown is the entered orientation => changed to As Built rotated 270 degrees).
Wall Overhang
V # Ornt ID - Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening
1 N=>W 1 Vinyl Low-E Double Yes 0.34 0.31 31.0 ft2 1 ft 0 in 10 ft 0 in Drapes/blinds None
2 N=>W 1 Vinyl Low-E Double Yes 0.34 0.31 2.5 ft2 6 ft 2 in 0 ft 0 in Drapes/blinds None
3 S=>E 3 Vinyl Low-E Double Yes 0.34 0.31 46.5 ft2 1 ft 0 in 10 ft 6 in Drapes/blinds None
4 S=>E 3 Metal Low-E Double Yes 0.55 0.34 40.0 ft2 1 ft 0 in 1 ft 3 in Drapes/blinds None
5 N=>W 7 Vinyl Low-E Double Yes 0.34 0.31 6.0 ft2 1 ft 0 in 0 ft 6 in Drapes/blinds None
6 N=>W 7 Vinyl Low-E Double Yes 0.34' 0.31 31.0 ft2 1 It 0 in 2 ft 6 in Drapes/blinds None
7 S=>E 9 Vinyl Low-E Double Yes 0.34 0.31 62.0 ft2 1 ft 0 in 0 ft 6 in Drapes/blinds None
8 N=>W 7 Vinyl Low-E Double Yes 0.34 0.31 31.0 ft2 1 ft 0 in 0 ft 6 in Drapes/blinds None
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 437.038 ft2 437.038 ft2 48.4 ft 8.67 ft 0
1 1/9/201 7 9:57 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5
1 ,
FORM R405-M 4
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000368 2517.6 138.21 259.93 .3402 7
HEATING-SYSTEM
# System Type Subtype Efficiency Capacity Block Ducts
1 Electric Heat Pump None HSPF:8.2 41 kBtu/hr 1 sys#1
COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit None SEER:14 40 kBtu/hr 1200 cfm 0.75 1 sys#1
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.95 50 gal 70 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None ftz
DUCTS
----Supply---- ----Return---- Air CFM 25 CFM25 HVAC#
# Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool
1 Attic 6 261 ftz 2nd Floor 45 ft2 Proposed On 2nd Floor ---cfm 130.3 cfm 0.05 0.60 1 1
TEMPERATURES
Programable Thermostat:Y Ceiling Fans:
Coolin r Jan rr Feb rr 11 Mar Apr r Ma rj Jun rX�Jul Au Se Oct Nov Dec
Heating [X}Jan rX}Feb [Xl Mar APr [ MaY Jun [ ]Jul AuSeP Oct Nov Dec
Ventin [[[ ]]Jan [[ 1 Feb [[[[[[X]]Mar A r [[[ Ma Jun [[[ ]Jul Aug Se Oct Nov Dec
11/9/2017 9:57 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5
FORM.R405-2014
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(Wl)) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
11/9/2017 9:57 AM EnergyGauge@ USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5
FORM R405-2014
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the EnergyPerformance Index,the more efficient the home.
Zephyrhills, FL,
1. New construction or existing New(From Plans) 9. Wall Types Insulation Area
2. Single family or multiple family Single-family a.Frame-Wood, Exterior R=11.0 1285.30 ft2
b.Concrete Block-Int Insul, Exterior R=4.1 996.67 ft2
3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 332.22 ft2
4. Number of Bedrooms 5 d.N/A R= ft2
10.Ceiling Types Insulation Area
5. Is this a worst case? No a.Under Attic(Vented) R=30.0 1541.00 ft2
6. Conditioned floor area(ft2) 2605 b.N/A R= ft2
7. Windows" Description Area c.N/A R= ft2
a. U-Factor: Dbl,U=0.34 210.00 ft2 11.Ducts R ft2
SHGC: SHGC=0.31 a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 261
b. U-Factor: Dbl,U=0.55 40.00 ft2
SHGC: SHGC=0.34 12.Cooling systems kBtu/hr Efficiency
c. U-Factor: N/A ft2 a.Central Unit 40.0 SEER:14.00
SHGC:
d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency
SHGC: a.Electric Heat Pump 41.0 HSPF:8.20
Area Weighted Average Overhang Depth: 1.052 ft.
Area Weighted Average SHGC: 0.315
8. Floor Types Insulation Area 14. Hot water systems Cap:50 gallons
a.Slab-On-Grade Edge Insulation R=0.0 1104.00 ft2 a.Electric EF:0.95
b.Raised Floor R=19.0 437.00 ft2
c.N/A - R= ft2 b. Conservation features
None
15.Credits Pstat
I certify that this home has complied with the Florida Energy Efficiency Code for Building f�kiE S7~,q�
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: ']
Date:
Address of New Home: ' City/FL Zip:
cob W-E �
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for nergy efficient
mortgage (EEM) incentives if you obtain.a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
11/9/2017 9:57 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1
FORM R405-2014
Florida Department of Business and Professional Regulations
Residential Whole Building Performance and Prescriptive Methods
ADDRESS: Permit Number:
Zephyrhills,FL,
MANDATORY REQUIREMENTS See individual code sections for full details.
401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL)
display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law
[Section 553.9085,Florida Statues]requires the EPL display card to be included as an addendum to each sales contract for both presold and
nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components
installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans
and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix C. -
❑ R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of
Sections R402.1 through R402.4.4.
O R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.The
sealing methods between dissimilar materials shall allow for differential expansion and contraction.
• R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in
accordance with the manufacturer's instructions and the criteria listed in Table 402.4.1.1,as applicable to the method of construction.
Where required by the code official,an approved third party shall inspect all components and verify compliance.
• R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air
changes per hour in Climate Zones 1 and 2,and 3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with
a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an
approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code
official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
During testing:
1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or
other infiltration control measures;
2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended
infiltration control measures;
3.Interior doors,if installed at the time of the test,shall be open;
4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed;
5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and
6.Supply and return registers,if installed at the time of the test,shall be fully open.
O R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers and outdoor combustion air.
O R402.4.3 Fenestration air leakage.Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm
per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400 or
AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer.
Exception: Site-built windows,skylights and doors.
O R402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage
between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not
more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential.All recessed
luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering.
R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system.
R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls
that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load.
R403.2.2 Sealing(Mandatory)AII ducts,air handlers,and filter boxes and building cavities that form the primary air containment
passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance
with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post-construction
or rough-in testing below.
Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either an energy rater certified in accordance with Section
553.99, Florida Statutes,or as authorized by Florida Statutes,to be"substantially leak free"by either of the following:
1. Post-construction test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area
when tested at a pressure differential of 0.1 inches w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure.All
register boots shall be taped or otherwise sealed during the.test.
2. Rough-in test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested
at a pressure differential of 0.1 inches w.g.(2513a)across the system,including the manufacturer's air handler enclosure.All registers shall be
taped or otherwise sealed during the test.If the air handler is not installed at the time of the test,total leakage shall be less than or equal to 3 cfm
(85 Umin)per 100 square feet(9.29 m2)of conditioned floor area.
Exceptions:
1. The total leakage test is not required for ducts and air handlers located entirely within the.building envelope.
2. Duct testing is not mandatory for buildings complying by Section R405 of this code.
11/9/2017 9:57 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Com Page 1 of 3
FORM R405-2014
MANDATORY REQUIREMENTS . (Continued)
❑ R403.2.3 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums.
❑ R403.3 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C)
or below 550F(13°C)shall be insulated to a minimum of R-3.,
R403.3.1 Protection of piping insulation.
❑ R403.4.1 Circulating hot water systems(Mandatory). Circulating hot water systems shall be provided with an automatic or readily
accessible manual switch that can turn off the hot-water circulating pump when the system is not in use.
❑ R403.4.3 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have .
heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a
downward and upward bend of at least 3 1/2 inches(89 mm)in the hot water distribution line and cold water line located as close as possible
to the storage tank.
❑ R403.4.4 Water heater efficiencies(Mandatory).
O R403.4.4.1 Storage water heater temperature controls
• R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls
capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum
temperature setting range shall be from 1001F to 140°F(38°C to 60°C).
• R403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied
to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s)
of combustion types of service water heating systems to be turned off.
O R403.4.4.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of
Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed.
Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water
heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1.
R403.4.4.2.1 Solar water heating systems. Solar systems for domestic hot water production are rated by the annual solar energy
factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of
Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors,
and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol,Collectors in installed solar water
heating systems should meet the following criteria:
1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and
2. Be installed at an orientation within 45 degrees of true south.
❑ R403.5 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the
Florida Building Code,Residential or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation.
Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating.
❑ R403.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment.
O R403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the
equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies,
based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and
indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions
described in Section R302.1.This code does not allow designer safety factors,provisions for future expansion or other factors
which affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation
such as standard kitchen and bathroom exhaust systems.
• R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the
calculated total load,but not more than 1.15 times greater than the total load calculated according to the procedure selected in
Section 403.6,or.the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the
equipment shall not be less than the calculated latent load.
1 1/9/201 7 9:57 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Com Page 2 of 3
FORM R4052014
MANDATORY REQUIREMENTS - (Continued)
O R403.6.1.1 cooling equipment capacity.(continued) The published value for AHRI total capacity is a nominal,rating-test value and
shall not be used for equipment sizing.Manufacture's expanded performance data shall be used to select cooling-only equipment.This
selection shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry bulb temperature for the
load calculation(or entering water temperature for water-source equipment),the blower cfm provided by the expanded performance data,
the design value for entering wet bulb temperature and the design value for entering dry bulb temperature.
Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load
calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space:
Exceptions:
1. Attached single-and multi-family residential equipment sizing may be selected so that its cooling capacity is less than the
calculated total sensible load but not less than 80 percent of that load.
2. When signed and sealed by a Florida-registered engineer,in attached single-and multi-family units,the capacity of
equipment may be sized in accordance with good design practice.
O R403.6.1.2 Heating equipment capacity
. R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section
R403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load.
. R403.6.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design
requirements calculated according to the procedure selected in Section R403.6.1.
. R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners
shall not be less than the design load calculated in accordance with Section R403.6.1.
O R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an
intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to
prevent continuous space cooling or heating within that space by one or more of the following options:
1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas.
2. A variable capacity system sized for optimum performance during base load periods is utilized.
❑ R403.7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections
C403 and C404 of the Commercial Provisions in lieu of Section R403.
❑ R403.8 Snow melt system controls(Mandatory). Snow and ice-melting systems,supplied through energy service to the building,shall
include automatic controls capable of shutting off the system when the pavement temperature is above 55°F,and no precipitation is falling
and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40oF.
❑ R403.9 Swimming pools,inground spas and portable spas(Mandatory). The energy requirements for residential pools and
inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSI/APSP-15.The energy
requirements for portable spas shall be in accordance with ANSI/APSP-14.
O R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on-off switch that is mounted
outside the heater to allow shutting off the heater without adjusting the thermostat setting.
R403.9.1.1 Gas and oil-fired pool and spa heaters. All gas-and oil-fired pool and space heaters shall have a minimum
thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013 when tested in accordance with ANSI Z 21.56.
Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights.
R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance
with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is
required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard.
O R403.9.2 Time switches. Time switches or other control method that can automatically turn off and on heaters and pumps according to a
preset schedule shall be installed on all heaters and pumps. Heaters,pumps and motors that have built in timers shall be deemed in
compliance with this equipment.
Exceptions:
• 1. Where public health standards require 24-hour pump operations.
2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems.
3. Where pumps are powered exclusively from on-site renewable generation.
O R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor-retardant cover on or
at the water surface or a liquid cover or other means proven to reduce heat loss.
Exception: Outdoor pools deriving over 70 percent of the energy for heating from site-recovered energy,such as a heat pump or
solar energy source computed over an operating season.
❑ RR404.1 Lighting equipment(Mandatory). A minimum of 75 percent of the lamps in permanently installed lighting fixtures shall be
high-efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps.
Exception: Low-voltage lighting shall not be required to utilize high-efficacy lamps.
O R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights
❑ R405.2 Performance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R-6.
O R405.2.1 Performance ONLY. Ceilings shall have minimum insulation of R-19.Where single assemby of the exposed deck and beam type or
concrete deck roofs do not have suff!cent space, R-10 is allowed.
11/9/2017 9:57 AM EnergyGaugeO USA-FlaRes2014 -Section R405.4.1 Com Page 3 of 3
FORM R405-2014
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: Hayden 2605 Elev C Builder Name: DRH Express Homes
Street: Permit Office:
City,State,Zip: Zephyrhills, FL, Permit Number:
Owner: Jurisdiction:
Design Location: FL,Tampa
COMPONENT CRITERIA CHECK
Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope.
Exterior thermal envelope contains a continuous barrier.
Breaks or joints in the air barrier shall be sealed.
Air-permeable insulation shall not be used as a sealing material.
Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the
insulation and any gaps in the air barrier shall be sealed.
Access openings,drop down stairs or knee wall doors to unconditioned
attic spaces shall be sealed.
Corners and headers shall be insulated and the junction of the foundation
Walls and sill plate shall be sealed.
The junction of the top plate and the top or exterior walls shall be sealed.
Exterior thermal envelope insulation for framed walls shall be installed in
substantial contact and continuous alignment with the air barrier.
Knee walls shall be sealed.
Windows, skylights and doors The space between window/door jambs and framing and skylights and
framing shall be sealed.
Rim joists Rim joists are insulated and include an air barrier.
Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside
and cantilevered floors) of subfloor decking.
The air barrier shall be installed at any exposed edge of insulation.
Crawl space walls Where provided in lieu of floor insulation,insulation shall be permanently
attached to the crawlspace walls.
Exposed earth in unvented crawl spaces shall be covered with a Class I
vapor retarder with overlapping joints taped.
Shafts, penetrations Duct shafts, utility penetrations,and flue shaft openings to exterior or
unconditioned space shall be sealed.
Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled
by insulation that on installation readily conforms to the available cavity
spaces.
Garage separation Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be
air tight, IC rated, and sealed to the drywall.
Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in
exterior walls,or insulation that on installation readily conforms to available
space shall extend behind piping and wiring.
Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air
barrier installed separating them from the showers and tubs.
Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or
air sealed boxes shall be installed.
HVAC register boots HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub-floor or drywall.
Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have
gasketed doors
1 1/9/201 7 9:58 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Envelope Leakage Test Report
Prescriptive and Performance Method
Project Name: Hayden 2605 Elev C Builder Name: DRH Express Homes
Street: Permit Office:
City,State,Zip: -Zephyrhills, FL, Permit Number:
Design Location: FL,Tampa Jurisdiction:
Cond. Floor Area:: 2605 sq.ft. Cond.Volume: 21580 cu ft.
Envelope Leakage Test Results Leakage Characteristics
Regression Data:
C: n: R:
CFM(50):
Single or Multi Point Test Data
HOUSE PRESSURE FLOW: ELA'
1 Pa cfm EgLA:
2 Pa cfm ACH:
3 Pa cfm ACH(50):
4 Pa cfm
5 Pa cfm SLA:
6 Pa cfm
R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour
in Climate Zones 1 and 2,3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2
inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the
test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all
penetrations of the building thermal envelope.
During testing:
1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other
infiltration control measures;
2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration
control measures;
3.Interior doors,if installed at the time of the test,shall be open;
4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed;
5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and
6.Supply and return registers,if installed at the time of the test,shall be fully open.
hereby certify that the above envelope leakage Where required by the code official, of'tl4EST,gTaE
performance results demonstrate compliance testing shall be conducted by an
with Florida Energy Code requirements in approved third party. A written
accordance with Section R402.4.1.2. report of the results of the test shall F" 'r'�" ''' ' "' '` "
be signed by the third party .......,;i - C .
conducting the test and provided toI�'' n
SIGNATURE: the code official.
PRINTED NAME: t''OZj WE
BUILDING OFFICIAL:
DATE: DATE:
1 1/9/201 7 9:58 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1
FORM,R405-201 4 Duct Leakage Test Report Performance Method
FLORIDA ENERGY EFFICIENCY CODE
FOR BUILDING CONSTRUCTION
Form R405 Duct Leakage Test Report
Performance Method
Project Name: Hayden 2605 Elev C Builder Name: DRH Express Homes
Street: Permit Office:
City,State,Zip: Zephyrhills, FL, Permit Number:
Design Location: FL,Tampa Jurisdiction:
Duct Test Time: Post Construction
Duct Leakage Test Results
CFM25 Duct Leakage Test Values
Line System Outside Duct Leakage
1 System 1 cfm25(Out)
2 System 2 cfm25(Out)
3 System 3 cfm25(Out)
4 System 4 cfm25(Out)
5 Total House Sum lines 1-4
Duct System
Divide by
Leakage
(Total Conditioned Floor Area)
(On,Out)
I certify the tested duct leakage to outside, Qn, is
not greater than the proposed duct leakage On Duct tightness shall be verified by �y�`��E s�AT�,
specified on Form R405-2014. testing to Section 803 of the RESNET �,/,,,f, ^
Standards by an energy rater certified.in
accordance with Section 553.99,
Florida Statutes.
SIGNATURE: t '
PRINTED NAME: WE
DATE: BUILDING OFFICIAL:
DATE:
1 1/9/201 7 9:58 AM EnergyGaugeO USA-FlaRes2014 -Section R405.4.1 Compliant S Page 1 of 1
Manual S Com liance Re ort Job:
-� wrightsoft® p p Date: Oct 10,2014
Entire House By:
Progressive Air Systems, Inc
5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669
Project • •
For: DR Horton/Express
Lot 18 Blk 6 Silverado Ranch, Zephyrhills, FL
Coo'ling Equfpment
Design Conditions
Outdoor design DB: 91.2°F Sensible gain: 32055 Btuh Entering coil DB: 76.4°F
Outdoor design WB: 77.1 OF Latent gain: 4144 Btuh Entering coil WB: 63.2°F
Indoor design DB: 75.0°F Total gain: 36199 Btuh
Indoor RH: 50% Estimated airflow: 1367 cfm
Manufacturer's Performance Data at Actual Design Conditions
Equipmenttype: SplitASHP
Manufacturer: Carrier Model: CH14NB042****A+FB4CNP042
Actual airflow: 1367 cfm
Sensible capacity: 32445 Btuh 101%of load
Latent capacity: 6269 Btuh 151%of load
Total capacity: 38714 Btuh 107%of load SHR: 84%
'Heatin•, Equipment
Design Conditions
Outdoor design DB: 40.0°F Heat loss: 27149 Btuh Entering coil DB: 69.5°F
Indoor design DB: 70.0°F
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: Split ASHP
Manufacturer: Carrier Model: CH14NB042****A+FB4CNP042
Actual airflow: 1367 cfm
Output capacity: 37299 Btuh 137%of load. Capacity balance: 31 OF
Supplemental heat required: 0 Btuh Economic balance: -99 OF
Backup equipment type: Elec strip
Manufacturer: (Model:
Actual airflow: 1367 cfm
Output capacity: 8.6 kW 108%of load Temp. rise: 18 OF
Meets are all requirements of ACCA Manual S.
• wri htsofta 2017-Nov-09 09:58:27
9 Right-Suite®Universal 2017 17.0.21 RSU25554 Page 1
14CCA ...\Wrightsoft Files\Express homes\Hayden-4EHB.rup Calc=MJ8 House faces: W
Load Short Form
-� wrightsoft® L Date: Oct 10,2014
Entire House By:
Progressive Air Systems, Inc
5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669
-Projectormation
For: DR Horton/Express
Lot 18 Blk 6 Silverado Ranch, Zephyrhills, FL
Design Inf• •
Htg Clg Infiltration
Outside db(OF) 40 91 Method Simplified
Inside db(OF) 70 75 Construction quality Semi-tight
Design TD (OF) 30 16 Fireplaces 0
Daily range - L
Inside humidity (%) 50 50
Moisture difference(gr/lb) 26 54
HEATING EQUIPMENT COOLING EQUIPMENT
Make Carrier Make Carrier
Trade CARRIER Trade CARRIER
Model CH14NB042****A Cond CH14NB042****A
AHRI ref Coil FB4CNP042
AHRI ref
Efficiency 8 HSPF Efficiency 11.3 EER, 13.7 SEER
Heating input Sensible cooling 30750 Btuh
Heating output 38500 Btuh @ 47OF Latent cooling 10250 Btuh
Temperature rise 26 OF Total cooling 41000 Btuh
Actual air flow 1367 cfm Actual air flow 1367 cfm
Air flow factor 0.050 cfm/Btuh Air flow factor 0.043 cfm/Btuh
Static pressure 0.56 in H2O Static pressure 0.56 in H2O
Space thermostat Load sensible heat ratio 0.89
Capacity balance point=31 OF
Backup:
Input=9 kW, Output= 29290 Btuh, 100 AFUE
ROOM NAME Area Htg load Clg load Htg AVF Clg AVF
(ft2) (Btuh) (Btuh) (cfm) (cfm)
kitchen/living 608 7370 8460 371 361
bed 2 164 2960 1938 149 83
powder 59 968 367 49 16
flex 156 3106 3211 156 137
foyer 75 1443 917 73 39
stairs 44 0 0 0 0
bed4 181 1647 2131 83 91
bed3 184 1965 3356 99 143
wic 60 143 177 7 8
wic 2 32 706 911 36 39
m suite 277 2507 4064 126 173
bath 135 355 355 18 15
upstairs living 234 1366 2606 69 111
stairs 2 50 0 0 0 0
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wri htsoft6 2017-Nov-09 09:58:27
^� 9 Right-Suite®Universal 2017 17.0.21 RSU25554 Page 1
ACCK ...\Wrightsoft Files\Express homes\Hayden4EHB.rup Calc=MJ8 House faces: W
lged5 175 1606 2088 81 89
laundry 41 368 917 19 39
a/c 19 0 0 0 0
bath 3 96 639 559 32 24
hall 63 0 0 0 0
Entire House d 2651 - 27149 32055 1367 1367
Other equip loads 0 0
Equip. @ 1.00 RSM 32055
Latent cooling 4144
TOTALS 2651 27149 36199 1367 1367
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
rl htsoft® 2o17-Nov-09 09:58:27
w
^, 9 Right-Suite®Universal 2017 17.0.21 RSU25554 Page 2
AGM ...\Wdghtsoft Files\Express homes\Hayden-4EHB.rup Calc=MJ8 House faces: W
Job:
+wrightsoft& Project Summary Date: Oct 10,2014
Entire House By:
Progressive Air Systems, Inc
5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669
Proiect Information
For: DR Horton/Express
Lot 18 Blk 6 Silverado Ranch, Zephyrhills, FL
Notes:
Design Information
Weather: Tampa Intl AP, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 40 OF Outside db 91 OF
Inside db 70 OF Inside db 75 OF
Design TD 30 OF Design TD 16 OF
Daily range L
Relative humidity 50 %
Moisture difference 54 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 20520 Btuh Structure 23084 Btuh
Ducts 6629 Btuh Ducts 8971 Btuh
Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh
(gone) (none)
Humidification 0 Btuh Blower 0 Btuh
131131,99 0 Btuh
Equipment load 27149 Btuh Use manufacturer's data y
Rate/swing multiplier 1.00
Infiltration Equipment sensible load 32055 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Semi-tight
Fireplaces 0 Structure 2674 Btuh
Ducts 1469 Btuh
Central vent (0 cfm) 0 Btuh
Heating
n Cooling (Pone)
N 26M
Area(ft2) Equipment latent load 4144 Btuh
Volume(W) 22094 22094
Air changes/hour 0.22 0.11 Equipment total load 36199 Btuh
Equiv.AVF(cfm) .81 41 Req. total capacity at 0.75 SHR 3.6 ton
Heating Equipment Summary Cooling Equipment Summary
Make Carrier Make Carrier
Trade CARRIER Trade CARRIER
Model CH14NB042****A Cond CH14NB042****A
AHRI ref Coil F134CNP042
AHRI ref
Efficiency 8 HSPF Efficiency 11.3 EER, 13.7 SEER
Heating input Sensible cooling 30750 Btuh
Heating output 38500 Btuh Ca-) 47OF Latent cooling 10250 Btuh
Temperature rise 26 OF Total cooling 41000 Btuh
Actual air flow 1367 cfm Actual air flow 1367 cfm
Air flow factor 0.050 cfm/Btuh Air flow factor 0.043 cfm/Btuh
Static pressure 0.56 in H2O Static pressure 0.56 in H2O
Space thermostat Load sensible heat ratio 0.89
Capacity balance point=31 OF
Backup:
Input=9kW, Output=2929013tuh, 100AFUE
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wrightsof-V Right-Suite®Universal 2017 17.0.21 RSU25554. 2017-Nov-09 09:58:27
ACCK ...\Wdghtsoft Files\Express homes\Hayden4EHB.rup Calc=MJ8 House faces: W Page 1
FORM R405-2014
P
RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST
Florida Department of Business and Professional Regulation
Simulated Performance Alternative (Performance) Method
Applications for compliance with the 2014 Florida Building Code, Energy Conservation via the
residential Simulated Performance method shall include
❑ This checklist
❑ A Form R405 report that documents that the Proposed Design complies with Section
R405.3 of the Florida Energy Code. This form shall include a summary page
indicating home address, a-ratio and the pass or fail status along with summary
areas and types of components, whether the home was simulated as a worst-case
orientation, name and version of the compliance software tool, name of individual
completing the compliance report(1 page)and an input summary checklist that can
be used for field verification (usually 4 pages/may be greater).
❑ Energy Performance Level(EPL)Display Card(one page)
❑ Mandatory Requirements(three pages)
Required prior to CO for the Performance Method:
❑ Air Barrier and Insulation Inspection Component Criteria checklist(Table R402.4.1.1 -
one page)
❑ A completed Envelope Leakage Test Report(usually one page)
❑ If Form R405 duct leakage type indicates anything other than "default leakage", then a completed
Form R405 Duct Leakage Test Report(usually one page)
EnergyGauge@-USRCZB v5.1
11/9/2017 10:47:24 AM Page 1 of 1