18-19709
CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 19709 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL PERMIT INFORMATION LOCATION INFORMATION Permit#:19709 1 Issued: 5/29/2018 Address: 6504 WAGON TRAIL ST Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 266,079.30 Total Fees: 11,394.69 Subdivision: SILVERADO Amount Paid: 11,394.69 Date Paid: 5/29/2018 Parcel Number: 05-26-21-0080-00600-0170 CONTRACTOR INFORMATION OWNER INFORMATION Name: DR HORTON INC Name: DR HORTON INC Addr: 12602 TELECOM DR Address: 12602 TELECOM DR TAMPA, FL. 33637 TAMPA FL 33637-0935 Phone: Lic: Phone: 813-549-1968 Work Desc: CONSTRUCT SINGLE FAMILY 2,362 SQ FT APPLICATION FEES BUILDING FEE 1,088.77 ELECTRICAL FEE 222.53 PLUMBING FEE 148.35 MECHANICAL FEE 103.85 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE-sfr/100% 4,828.00 SCHOOL IMPACT FEE-sfr/1% 48.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32 O um C9- Inspections Required REINSPEC77ON FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. 0 &-- 6�00 CONTRACTORS SIGNATURE PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER i613-780-0020 City of Zephyrhills Permit Application Fax glaasa 0021 Building Department Date Received ` Phone Contact for Permitting Owner's Name IOwner Phone NumberL��G Owner's Address ! �' '-Fe ! `� `� p'f fDnf6�E / Owner Phone Number Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder.Address JOB ADDRESS k1,dCirkNl I `j SEL 'S LOT# 5UBDIV1510N �'��� PARCEL ID# � `/T` (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR 8 ADD/ALT �� SIGN O DEMOLISH INSTALL REPAIR PROPOSED USE �] SFR COMM OTHER' TYPE OF CONSTRUCTION . � BLOCK E FRAME STEEL 0 DESCRIPTION OFWORK BUILDING SIZE F 5Q FOOTAGE rL$ (p HEIGHT "t-�-r'r�_e�-a-rr-•r'r-r-w'-ra=r--e-rrr�e-Q-�-r-a-i"_ra-�-'e-������r4-¢-e-s-rp-a-�-�o-�-rp--t�-'rs�•¢-o-a-&"e-�s�'�-s-�e"e-l->s-e-fl- =BUI,LDING $ VALUATION OF TOTAL CONSTRUCTION DELECTRICAL $• ob AMP SERVICE PROGRESS ENERGY 0 W.R.E.C. o =PLUMBING $ _so =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION Iry [ ]GAS 0 ROOFING SPECIALTY OTHER FINISHED FLOOR ELEVATIONS 1 FLOOD ZONE AREA =YES NO -➢ ➢_ ➢_p..Q..�..Q_t�➢_.Q.➢..➢..➢_➢.#_g_Q._Q-�•.➢-p-I-.➢-➢-�.➢-$-,}-➢_I__I._1.4-4-911 1 1.4 g�➢�°�➢.a�:_it-S-�➢�g ➢�i�9--➢..g-Q-g-I- BUILDER r COMPANY l r. - �-�c7 -A-C SIGNATURE REGISTERED Y j N FEE CURREN Y/N Address % �;?j� 1 Cif.�-i r )�ra-r c License# ' ,,F-LECTRiCIAjV � � tc�,, / �. COMPANY SIGNATURE ' — REGISTERED Y/ N FEE CURREN Y/N Address �``e ,gv57:-�Fp ,l* - License# {� l/•=} C��7 � PLUMBER COMPANY f'" fl��f'tt�.f= •.�i �'G"t �^� ��.ra � C'�r;�� �d - �- SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address X License# T MECHANICAL COMPANY ,�"i� +�� +� 3r'� �' � SIGNATURE f '" C�' ^^^—"----REGISTERED Y(I/ N I FEE CURREN Y t N Address 5_,702 / .r she �?>sa a ?�,.• ?, � j' License# l ,� OTHER' .F.J ,-r- _„ COMPANY SIGNATURE p �-�' �� REGISTERED Y/ N FEE CURREN Y/N Address /Oxe' License# i ! Q i I ! ! ! !' ! ! ! 1 1 1 ! 1 1 ! i 1 ! ! ! i I ! 1 1 ! Q i I ! I i ! Q ! 1 1 1 ! 1 1 ! I ➢ 0 1 .➢ ➢ ➢ ➢ ! ➢ ➢ ! ! Q ! ➢ ➢ ➢ I ➢ ➢ RESIDENTIAL Attach (2) Piot Plans; (2)sets of Building Plans; (1)set of Energy Forms; R-O-W Permit.for new construction, Minimum ten (10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Sift.Fence installed, Sanitary Facilities&1 dumpster;Site Work•Permit for subdivisions/large projects COMMERCIAL Attach (2)complete sets of Building Plans plus a Life Safety Page; (1)set of Energy Forms. R-O-W Permit for new construction. Minimum ten (10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. "PROPERTY-SURVEY required for all NEW construction. -Directions: i re ct•. -i-B-Q-C--a-;-Q-t-➢-1-�--➢-d-.�.-Q-Q-.Q-Q-3-Go.Q-fi-Q-.E--b-3-Q-Q-I-.Q--0--d-➢- Q--6-Q-Q-4-Q-6-d-Q-�➢..n�➢�EmA�C.�-➢��➢®➢ .➢•�&-➢-Q-. rectioo nsns; Fill out application completely. Owner�Contractor sign back of application, notarized, If over$2500,,a Notice of Commencement is required. (A/C upgrades over$7500) Agent(for the'contractor)or Power of Attorney(for the owner)would be someone with notarized fetter from owner authorizing same )VER THE COUNTER PERMITTING (copy of contract required) 3eroofs if shingles • Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..r!eeds ROW . ` ` , ` ^ NOTICE OF DEED RESTRICTIONS: The undersigned unders1undotha1thkspnrm� maybenub^eotto "deed" reathctions". which may ba more restrictive than County regulations. The undersigned assumes responsibility forcompUonoewithmny" applicable deed restrictions. ' UNLICENSED CONTRACTORS AND CO0TRACTOR*RESPONSl8|L|T|ES' If owner has hired a c nnhactr or contractors tounde�ake work, they may bo required toba licensed in accordance with state and local regulations. If'-the contractor is noiiioenoed as required by |avv, both the owner and contractor may be cited for u misdemeanor violation under state law. If the owner or intended-contractorare uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at727-84T- ' 8009. Fudhermmre, if the owner has hired a contractor or nuntnaotons, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as th� contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges.in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation lmpa:ct Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buUd\ngs, or expansion of existing bui\d|nga, as specified in Pasco County Ordinance number 89-07 and 90-07, an amended. The undersigned also understands, that such fees, as may be dua, will be identified at'thednn* of permitting. it is furthAr understood that Transportation Impact Fees and Resource Recovery Fees, must be paid prior to receiving o "certificate of occupancy" or final power release. If the project does not Involve a certificate of occupancy or final power re|nasa, the fees must be paid prior to permit issuance. Furthermore. if Pasco-[|ountyVVe1er/8ewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW (Chapter 713, Florida Statutes, as amended): If valuation of work is $2.500.00 or more, | certify that |, the applicant, have been provided with a copy of the ','Florida Construction, Lien Law—Homeowner's Protection Guide" prepared by the.Florida Department ofAgriuu|turo.und Consumer Affairs. If the applicant is someone ` other than the "owner". | certify that | have obtained a copy ofthe above described document and promise in good faith to deliver itto the^oxvner' prior Locommencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: \ certify that all the information in this application is accurate and that all work will be done in compliance with all applicable |avva regulating oonotrucLiun, zoning and land development. Application is hereby made to obtain a permit to do.work and installation as indicated. | certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating nOnstruCt\on. County and City codes; zoning regu|ations, and land development regulations. in the jurisdiction. | also nert|fvthat | und�ratandthattheregu|a1\nnsofothe� governmentageno\es,muyapp(y0othe \ntendedwork. andthstlt \n my responsibility 'aponsibi|itytoident what actions \ must take tobeinnompUan'oe. Such agencies include but are not limited tcc - Department of Environmental Protection-Cypress Bayheads. Wetland Areas and Environmentally Sensitive Lands,VVatan*&/astuvva1orTreatmont. ' Southwest Florida Water Management 0stdot-VVoUs, Cypress. Beyheads, Welland Areoa, Altering VVa1erouorsna. _ ' Army Corps ofEng\naem-SeawaUs. Docks, Navigable Waterways. ' ' Department of Health & Rehabilitative Services/Environmental Health Unit-VVe|\a, Wastewater Treatment,." Septic Tanks. _ - US1Envhnn mental Protection AQenoy'Anbe8tosabatement. - Federal Aviation Authohty-Ronwayo. \ understand that the following restrictions apply to the use offill: - Use of fill is not allowed \n Flood Zone "V" unless expressly permitted. - If the fill material is to be used in Hood Zone ''A'. it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared byaprofessional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "/Y' in connection w|th a.perrn\�ed building using atenovva|\' construction, | ne�dv that f)Uvv||\ be used only totU\the area vv�k|nthe otannwall. ' if fill material is to be used in any .area. | certify that use of such fill will not adversely affect adjacent . properties. If use of fill is found to adversely affect adjacent pruportios, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots \aoa than one (1) acre which are elevated by fill, an engineered drainage plan is required. if I am the AGENT FOR THE OWNER, I promise in,good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction., i understand that e separate permit may be.required for electrical work, p|unnbing, nigna, we||a` poo|s, air condh|on\ng. Qas.,or other installations not specifically included in the application. /\ permit i§sued's'hall be construed to be a license to proceed with-the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official frQm th.ereafter requiring a correction of errors1n plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within,six months of permit issuance, or if work authorized by the permit is'suap*nded or abandoned fbr a pehod^of six (6) months after the bmpthe Work is commenced. An extension may be' requested, in vvrhing, from the Building {}ffioia| for a period not to exceed ninety (00) days' and will demonstrate ` justifiable cause for the extension. If work ceases for ninety (90) consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FK\LOFlE TO RECORD A NOTICE OF COMMENCEMENT MAY RE8O[[ IN YOUR'. PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. |F YOU INTEND T0 OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF'COMMENCEMENT. FLORIDA^Un*/ (r.S. / /'uu) OWNER OR AGE 1-001- CONTRACTOR Subscribed'and swqm to (or affirmed)-before me this Subscribed and sworn.to(or affirmed)before me this by by Who is/are Personaltv known to me or has/have,produced vVhoIs/am personally known to me or has/have produced . � identification,as =�...~~"" ` ' . ' Notary Public ' Public ` - ` Commission No. Commission No. v ' Name"'Notary typed,printed o ="'p"" '`='~~'Notary~ typed,printed or~^~'p~dNotary Public State of Florida - (YMichelle moyes omp,) Expires 1212112020 /, C�D.R. Horton-6504 Wagon Trail St-2,362 sq ft �" Column Es SQ. FEET PRICE MAIN OR LIVING: 2,362 $ 112.65 OTHER AREA UNDER ROOF: _ $ 88.00 OTHER: - $ - VALUATION $ 266,079.30 FEE SHEET $ 989.00 ADDRESS $ 40.00 DRIVEWAY $ 40.00 BUILDING: $ 1,088.78 ELECTRICAL: $ 222.53 PLUMBING: $ 148.35 MECHANICAL: $ 103.85 SUB-TOTAL $ 1,563.50 TOTAL $ 1,563.50 SEWER: n/a WATER: n/a IRRIGATION: $ - TOTAL: $ - WATER METER: n/a IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $. . 2,116.85 PARK IMPACT FEES $ 769.56 SIF'S: $ 4,828.00 100.0% $ 4,828.00 1.0% $ 48.28 TOTAL: $ 4,876.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 11,394.69 D R HORTON INC-6504 Wagon Trail-2,362 sq ft Column SO. FEET PRICE MAIN OR LIVING: 2,362 $ 112.65 OTHER AREA UNDER ROOF: - OTHER: $ - VALUATION $ 266,079.30 FEE SHEET $ 989.00 ADDRESS $ 40.00 DRIVEWAY $ 40.00 BUILDING: $ 1,088.78 ELECTRICAL: $ 222.53 PLUMBING: $ 148.35 MECHANICAL: $ 103.85 SUB-TOTAL $ 1,563.50 TOTAL $ 1,563.50 SEWER: n/a WATER: n/a IRRIGATION: $ - TOTAL: $ - WATER METER: n/a IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES ° POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 2,116.85 PARK IMPACT FEES $ 769.56 SIF'S: $ 4,828.00 100.0% $ 4,828.00 1.0% $ 48.28 TOTAL: $ 4,876.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 11,394.69 INSTR#2018084891 ORBK9727 PG,3315 page 1 of 1 0512112018 01:50 PM Rcpt: 1958804 Rec'.10.00 DS:0.00 IT:0.00 pauCa S. 0'weiG Ph.D., Tasco CountyCCerk&Comytroffer Permit No. Parcel'ID No If, NOTICE OF COMMENCEMENT State of Florida- County of Pa QO THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in jc rdance with.Chapter 713,Florida Statutes, the following informa tion is provided in this Notice of Commencement- _91for- 1. Description of Property: Parcel Identification No. I-In 4- i 71 4�7/0"d C) Street Address: Ct - C_1 naj S�tre 2. General Description of Improvement New Single Family Residence 3. Owner Information or Lessee information if the Lessee contracted for the improvement D.R. HortQn.Inc Name 1?f302 Telprnm nrivP Tpryins 33637 171 Address City state Interest in Property: Fee Simple, - Name of Fee Simple Titleholder. (if different from Owner listed above) Address city State 4. Contractor. D.R.Horton. Inc Name 12602 Telecom Drive T;;mns 33637 FL Address "y State Contractor's Telephone No.: 5. surety: N/A Name Address city I State Amount of Bond: $ NIA Telephone No. 6. Lender. N/A Name Address city State Lender's Telephone No.: 7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)M,Florida Statutes: David Gude Name 12602 Telecom Drive Tampa 33637 FL Address city State Telephone Number of Designated Person: 813-740-9720 8. In addition to himself,the owner designates N/A Of to receive a copy of the Lienors Notice as prodded in Section 713,13(1)(b),Florida Statutes. Telephone Number of Person or Entity Designated by Owner. II 9. Expiration date of Notice of Commencement(the expiration date may not be before the completion of construction and final payment to the contractor,but will be one year from the date of recording unless a different date is specified): WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalty of perjury,I declare that I have read the foregoing notice of commencement and I at the facts stated therein are true to the best of my knowledge and belief. STATE OF FLORIDA COUNTY.OF PASCO W-I � 1,vx� SignaLure of Owner or Lessee,or Owners or Lessees Authorized Officer/Director/Partner/Manager Assistant Secretarv/D.L Horton, Inc Signatory's Tjtle/Office The foregoing instrument was acknowledged before me this I day of 20�rby 4 as-Assistant Secretary (type 0f aut'Ve e.g.,officer,trustee,attorney in fact)for o D.R. Horton, Inc (name,of party n b'e If, f hom instrument was executed). Personally Known C4 OR Produced Identification M Notary Signature Type of Identification Produced Name(Print) I h g,V Pj� Notary Public State of Florida k4lchelle Mayes My CorrimlWort r.G()M21 01,tv Expires 1212112020 wpdatalbesinoticecommencement_pc053048 05-26-21-0080-00600-0170 1 Pasco County Property Appraiser Page I of I Data Current as Of: Weekly Archive - Wednesday, May 16, 2018 Parcel ID 05-26-21-0080-00600-0170 (Card: 001 of 001) Classification 00 - Vacant Residential Mailing Address Property Value DR HORTON INC Ag Land $0 12602 TELECOM DR Land $3,215 TAMPA FL 33637-0935 Building $0 Physical Address Extra Features $0 6504 WAGON TRAIL STREET ZEPHYRHILLS, FL 33541 dust Value $3,215 Legal Description (First 4 Lines) Assessed (Non-Schbol Amendment 1) $3,215 SILVERADO RANCH SUBDIVISION PHASES 6, 8 &9A PB 75 PG 075 BLOCK 6 Taxable Value $3,215 LOT 17 Jurisdiction City of Zephyrhills Land Detail (Card: 001 of 001) Line 16s-e--,----IDescription'!,Zoning Units I Type jPrice !,Condition Lyalue 1 0100 SFR MPUD 6,000.00 SF $0.40 $2,400 --'2— ___61_0_0 ]' SFR I— �oo—oo 4 MPUD 3,259.00 aF $0.25 $815 Additional Land Information Acres 0.21 Tax Area io—si Residential Code SLVRCP1 Code Building Information - Use 00 - Unimproved (Card: 001 of 001) Unimproved Parcel 00 - Unimproved Extra Features (Card: 001 of 001) Line (Description Lear ju its jVa�lue No Extra Features Sales History- See All 6 sales Previous Owner: DUNE FL LAND I SUB LLC Month/Year Book/Page (Type DOR Code Condition Amount 05/2018 9725 / 0407 Warranty Deed 05 Vacant Muiti-Parcel Sale 5/2017 9535 L.Q546 Certificate of Title 05 ---.Vacant Multi-Parcel Sale '_TnA' 0 11/2016 t9462 0384 'T—Mineral Rights or Royalty Transfer 05 Vacant Multi-Parcel Sale http://search.pas,copa.com/parcel.aspx?parcel=2126050080006000170 5/18/2018 PASCO COUNTY T) A DEVELOPMENT SERVICES I--3LS C 7 JU 8731 Citizens Drive Date:8/15/2018 COUNTY FLORIDA New Port Richey, FL 34654 727-847-2411 INJOT A PERMIT Receipt#: 1784948 FEE DESCRIPTION ACCOUNT CODE UNITS INVOICE# FEE AMOUNT PAID RECEIPT# DATE I Impact Fee Residential Solid 24503100-329010 23.96 1374807 $23.96 $23.96 1184948 8/15/18 Waste Single Family TOTALS: $23.96 $23.96 Receipt# Paid By Check# CC Auth# Cashier ID Workstation Receipt Date Arnt Paid 1784948 Check 791246 555 BCCCP35W 08/1512018 $23.96 Total Payments: $23.96 Pa or Address Phone d r horton Comments:Z City of Zep s., City of Z 111MIld Waste 19 9 � '� C� Address- 504 Wagon 'ril St 5 0080 Parcel: 5 26 210080 006Lt 0170 While you will be pay with A�as'co County evelopment Services,the full amount of the credit card or e-check fees,NOT shown above,is collected by First Billing payment services. MyReports/reports//PASCOPROD/PASCO/ReceiptPOS—V6,rpt 8/15/2018 Page 1 of 1 PASCO COUNTY, FLORIDA Permit No, Date Permitted 5-0-10 Builder Name/Owner Name C- Control County Parcel No. 0,5-2_ -V_00 _ot)6d 04W 7 C)SubD!v: 3 Address/Location 71-m-, Classification/Type of Use 7_4� ICU U TRANSPORTATION IMPACT FEE Rate: Sq-FtUnit: Exempt nYes No How Determined impact Fee Amount Zone No. TAZ: SCHOOL IMPACT FEE Account (056) Single-Family Detached House Amount $ (057) Mobile Home (058) Other Residential (123) Collection Fee Exempt []Yes n No How Determined PARKS AND RECREATION FEE Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation Total Zone TOTAL AMOUNT $ Exempt F] Yes F1 No How Determined LIBRARY FEE Land Account Land Credit Land Total Facility Account Facility Credit Facility Total 174--y— Exempt n Yes No How Determined Total Amount-/ RESOURCE FEE ERU TOTAL AMOUNT Prepared By Checked By C/ NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE.OF PASCO COUNTY Acknowledgement below does not Imply acceptance of concurrence,but simply receipt of a copy of this form,placing the building permit owner on notice of this assessment and the conditions of payment for same. DATE RECEIVED BY RECEIPT NO. DATE BY Q_c�.fj o I.�RIIIUR M City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: - Date Received: Site: G Permit Type: Approved w/no comments:❑ Approved w/the below comments:)EP Denied w/the below comments: ❑ s-'� j Age/ This comment sheet shall be kept with the permit and/or plans. Kalvin Swig e " I lans Examiner Date Contractor and/or Homeowner , (Required when comments are present) Single. Family Dwelling Pl : . an Review.Comments- 1: T.F.E. shall be a.minimum:of 8" above.the road-elevation-and an engineered site plan. . 2. Lots shall be graded to comply with R401.3 of the F.B.C. 3. .Compaction test required if 24" or more,of fill dirt is brought,in at any one place: 4 Tie in survey required before pouring concrete.. 5.. Driveways:require a R:O:W. use permit All 4 sides of driveway thru the sidewalk shall have expansion material.. 6.. All setbacks.'shall be met... 7. All property.markers shall be.uncovered and marked at time of first 'inspection: 8: All A.D.A. requirements shall be met.: . 9. No electric;plumbing,mechanical, or fraining shall be,covered without an inspection and approval first. . . 10. A11.Gara es shall.comply with section R302:6.of the RB:C.::(Fir Separation)._ . . . 11.Appliances:shall not:be installed in:a'location where subject to,mechanical damage unless. protected by approved barriers. -M303.4 of the F.B:C 12. Water heaters shall comply:with section.P607.3 of the F.R.C. 13. Foundation supports for A/C.units shall'be raised at least 3" above finished grade. M 13-08.1 14. Return-air in-all-bedrooms. F.B.C. M,1620.4 - 15. Smoke detectors areto be installed iin accordance with R313a of the F.B.C. 16..:All glazing requirements are:.to be in accordance'with R308.4.of the F.B.C. 17. All means_of egress are to.be in accordance with R311-6f the R.B.C. . 18. `-`Green gypsum board shall not be used as.a backer in showers or tubs. R702.4:2.-F.B.C. 19.'Combination-typeAFCI-breakers.are-required_at all locations requiring.an AFCI-type breaker: .20. Carbon monoxide alarms will be required in new construction that uses fossil-burninkheating or appliances or an attached garage:. They shall be installed in accordance with,the F.B.C: 21. All plumbing;mechanical,:and electrical shall be separate from unit to unit: This includes all. underground plumbing and electric: 22. All 2011.N:E:C. Codes will be .enforced:. 23.Tamper=Resistant Receptacles in accordance with 406.1 f of the 2011 N:E:C 24-An accordance.with the Land Development:Code' lots shall be sodded before final at least-10 feet'around'the.structure: 25.A copy of the eneau caels shall be with:pernat at all times. 26 Copy of�nal.insulation report-shall be.Provided with.permit-before.final F.F.E.-Finished Floor Elevation F.B.C- Florida Building Code 6 h Edition R.O.W.-Right'of Way A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code (2011): . PLOT PLAN DESCRIPTION:(AS FURNISHED) LOT 17, BLOCK 6, SILVERADO RANCH SUBDIVISION PHASE 6, 8 & 9A AS RECORDED IN PLAT BOOK 75, PAGE(S) 75-80, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. Curve Table Curve# Length Real.. Delta Chord B-cx-rig Chord CI 41.38' 55.DD` 43-06-37- N31-41.18-W 40.41' /10 .1 'Poo, (0 105A 11_�I 0 z 1053 0 1 30' / " 6 ;A GRAPHIC SCALE 0 b 17 30 �4 tv, tp,61 iFs. 00 0 r q, '0 �0 00, ,n CID 0 j. _0 .0. 112-50 PC S7 14'19 ?0. RP 1§1 LOT 18 BLOCK 6 . ON LOT CALCULATIONS LOT = 9,259 SQ. FT. LIVING AREA = 1,828 SO. FT. GARAGE = 430 ENTRY = 16 SO. FT. LANAI = 88 SQ. FT. PATIO = 0 SO. FT. DRIVEWAY = 348 SQ. FT. t> A/C PAD = 12 SO. FT. WALKWAY = 28 SQ. Ft IMPERVIOUS = 307. = 2750 SQ. FT. PREPARED FOR: SOD .= 6,509 SO. FT. OFF LOT CALCULATIONS RIGHT OF WAY = 271 SO. FT. DRIVE APRON = 41 SQ. FT. PUBLIC S/W = 198 SQ. FT. BUILDING SETBACKS SOD = 32 SO. FT. TOTALS FRONT- 20' AREA = 9,530 SQ. FT. REAR: 15, DRIVEWAY M 389 - SO. FT. S:DE. 7.5' SIDEWALK = 226 SO. FT. SIDE STREET. 20' SOD = 6,541 SO. FT. NOTES: LEGEND: BU 1. ELEVATIONS SHOWN ARE PER LOT GRADING ILDING SETBACK LINE PI POINT OF INTERSECTION CENTERLINE PLANS PROVIDED BY THE CLIENT. PT PC PO!PONT OF TANGENCYNT OF CURVATURE 2. ELEVATIONS ARE BASED ON NAVD 1988 RIGHT OF WAY LINE RP RADIUS POINT DATUM. PRC POINT OF REVERSE CURVATURE PROPOSED ELEVATION PCC POINT OF COMPOUND CURVATURE I AL THIS PLOT PLAN IS INTENDED FOR PERMITTING PURPOSES. PROPOSED DRAINAGE FLOW CS TYP CONTYPICCRETE SLAB ONLY. THIS IS NOT INTENDED FOR THE CONSTRUCTION OF THE PROPOSED HOUSE. REFER TO HOUSE PLAN.AND CONCRETE (C) CALCULATED OPTION LIST FOR CONSTRUCTION. ALL BUILDING SET BACK A/C AIR CONDITIONER PB PLAT BOOK LINES SHOWN HEREON IS PER DATA FURNISHED BY CLIENT S/W SIDEWALK PGS PAGES AND IS FOR INFORMATIONAL PURPOSES ONLY. SO. FT. SQUARE FEET F.EJA.A. FEDERAL EMERGENCY MANAGEMENT AGENCY F.I.R.M. FLOOD RATE MAP THIS IS NOT A SURVEY NAVD NORTH AMERICANINSURANCE VERTICAL DATUM NGVD NATIONAL GEODETIC VERTICAL DATUM THIS IS A PLOT PLAN ONLY D&AJE DRAINAGE&UTILITY EASEMENT POE PRIVATE DRAINAGE EASEMENT FLOOD NOTE: UE UTILITY EASEMENT(PUBLIC) I HAVE EXAMINED THE F.I.R.M. MAP NO. 12101CO288F, DATED SEPTEMBER 26. 2014, AND FOUND 1HE SUBJECT PROPERTY SURVEYOR NOTES:, APPEARS TO UE IN ZONE'X*, AREAS OUTSIDE THE 100 YEAR 1. THE SURVEYOR HAS NOT ABSTRACTED THE FLOODPLAIN AND ZONE -A-,AREAS DETERMINED TO BE SPECIAL FLOOD LAND SHOWN HEREON FOR EASEMENTS, RIGHT HAZARD AREAS SUBJECT To INUNDATION BY THE 1%ANNUAL CHANCE OF'WAY, RESTRICTIONS OF RECORD WHICH FLOOD EVENT, THE SURVEYOR MAKES NO GUARANTEES AS TO THE MAY AFFECT THE TITLE OR USE OF THE LAND. ABOVE INFORMATION.PLEASE CONTACT THE LOCAL F.E.M.A. AGENT FOR VERIFICATION. 2. NO UNDERGROUND IMPROVEMENTS HAVE BEEN BEARING BASIS: LOCATED EXCEPT AS SHOWN. BEARINGS SHOWN HEREON ARE BASED ON THE CENTERLINE OF WAGON A5111 3. NOT VALID WITHOUT THE AUTHENTIC TRAIL STREET BEING N5335'22*W.PER PLAT. ELECTRONIC SIGNATURE AND THE AUTHENTIC ELECTRONIC SEAL OF A FLORIDA LICENSED (FIELD DATE:) REVISED: KA F= Fz;," I C� SURVEYOR AND MAPPER. SCALE: 1" 30 FEET �S U F;,*\/E='%w00'j Dj'i,ally itgned by James W Dolman an APPROVED BY-. jB 8c MAPPING INC- 0% o=Amafiasn Surveying&Mapping, • CERTIFICA71ON OF AUTHORIZATION NUMBER LB#6393 TM m e no, 171013 LOT 17, EILK 6 3191 MAGUIRE BOULEVARD, SUITE 200 @wmcarpomte.com, JOB NO. FOR ORLANDO, FLORIDA 32803 E RAWN BY. DSB (407) 426-7979 RM ME DATE PLOT PLAN 11/10/17 KJW WWW.AMERICANSURVEYINGANDMAPPING.COM JA S W. BOLEMAN PSM# 6485 FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Cali 1828 El'ev D� ._\ I ( Builder Name: DR ExpHorrtes `� Street: �-jt� J Permit Office: CI P7�Il iu City,State,Zip: %pphyrhills,FL,`�J��� /I ( Permit Number:�Q 70,9 Owner: 5s � ( Jurisdiction: Design Location: FL,Tampa ` County:: Pasco(Florida Climate Zone 2) 1. New construction of existing New(From Plans) 9. Wall Types(1710.2 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul, Exterior R=4.1 1404.00 ftz b.Frame-Wood,Adjacent R=11.0 306.22 ft2 3. Number of units,if multiple family 1 c.N/A R= ftz 4. Number of Bedrooms 4 d.N/A R= ftz 10.Ceiling Types (1828.0 sqft.) Insulation Area 5. Is this a worst case? No a.Under Attic(Vented) R=30.0 1828.00 ftz 6. Conditioned floor area above grade(ftz) 1828 b.N/A R= ftz Conditioned floor area below grade(ftz) 0 c. R= ftz 11. Duct s R ftz 7. Windows(166.5 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 356 a. U-Factor: Dbl,U=0.34 126.50 ftz SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.55 40.00 ftz 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.34 a.Central Unit 28.6 SEER:14.00 c. U-Factor: N/A ftz SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ftz a.Electric Heat Pump 28.6 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 2.722 ft. Area Weighted Average SHGC: 0.317 14.Hot water systems 8. Floor Types (1828.0 sqft.) Insulation Area a.Electric Cap:50 gallonsEF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1828.00 ftz b. Conservation features b.N/A R= ftz None c.N/A R= ftz 15.Credits Pstat Glass/Floor Area: 0.091 f1a7�7ASS Total Proposed Modified Loads: 60.72 P Total Baseline Loads: 61.25 I hereby certify that the plans and specifications covered by Review of the plans and "SKE ST,q? this calculation are in compliance with the Florida Energy specifications covered by this _ 4_1 pit Code. calculation indicates compliances+ A with the Florida Energy Code. Jrrrrr�'r:•';: .`�';,,r PREPARED BY: cs[ Before construction is completed t7 DATE: a-a-n this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. 4. with the Florida Energy Code. GAD WE�g�1 OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: l�' - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with Section 803 of RESNET Standards, is not greater than 0.060 Qn for whole house. 11/9/2017 10:39 AM EnergyGauge@ USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION- Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Call 1828 Elev D Builder Name: DRH Express Homes (�""< I Permit Office: Street: 'zc" ��pa o t I ud' ' �q'l' ' City,State,Zip: ��e-p.hyr.hil ,FL, Permit Number: Owner: lT Jurisdiction: Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2 I New construction or existing New(From Plans) .9. Wall Types(1710.2 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1- 1404.00 ft2 b.Frame-Wood,Adjacent R=1 1.0 306.22 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 4 d.N/A R= ft2 10.Ceiling Types (1828.0 sqft.) Insulation Area 5. Is this a worst case? No a.Under Attic(Vented) R=30.0 1828.00 ft2 6. Conditioned floor area above grade(W) 1828 b.N/A J R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11. Ducts R ft2 7. Windows(I 66.5 scift.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 356 a. U-Factor: Dbl,U=0.34 126.50 ft2 SHGC: SHGC=0.31 b. U-Factor: DbI,U=0.55 40.00 112 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.34 a.Central Unit 28.6 SEER:14.00 c. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 28.6 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 2.722 ft. Area Weighted Average SHGC: 0,317 14. Hot water systems 8. Floor Types (1828.0 sqft.) Insulation Area a.Electric Cap:50 gallons EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1828.00 ft2 b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.091 Total Proposed Modified Loads: 60.72 PASS Total Baseline Loads: 61.25 I hereby certify that the plans and specifications covered by Review of the plans and iES7.'-J this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: L c .. Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. SOD WE OWNER/AGENT"' ',: � BUILDING Q' FFICIAL A2� DATE: DATE: - C6inpliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. - Compliance with a proposed duct leakage On requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with Section 803 of RESNET Standards,is not greater than 0.060 On for whole house. 11/9/2017 10:39 AM EnergyGauge@ USA-FIaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 FORM R405-2014 PROJECT Title: Cali 1828 Elev D Bedrooms: 4 Address Type: Lot Information Building Type: User Conditioned Area: 1828 Lot# 17/6 Owner: Total Stories: 1 Block/SubDivision: Silverado Ranch #of Units: 1 Worst Case: No PlatBook: Builder Name: DRH Express Homes Rotate Angle: 225 Street: Permit Office: Cross Ventilation: County: Pasco Jurisdiction: Whole House Fan: City,State,Zip: Zephyrhills, Family Type: Single-family FL, New/Existing: New(From Plans) Comment: Garage L Face SW CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp v Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Tampa FL_TAMPA_INTERNATI 2 39 91 70 75 645.5 54 Medium BLOCKS Number Name Area Volume 1 Blockl 1828 15848.8 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1828 15848.8 Yes 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio Main 198.6 ft 0 1828 ftz ---- 0 0.25 0.75 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 2044 ftz 0 ftz Dark 0.92 No 0.9 No 0 26.6 ATTIC V # Type Ventilation -Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 1828 ftz Y N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) Main 30 Blown 1828 ftz 0.11 Wood 11/9/2017 10:39 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 4 FORM R405-2014' WALLS Adjacent Cav Space ity Width Height Sheathing Framing Solar Below _ 1 N=>SW Exterior Concrete Block-Int Insul Main 4.0999 19 8 8 164.7 ft2 0 0.6 0 _2 E=>NW Exterior Concrete Block-Int Insul Main 4.0999 43 8 8 8 378.4 ft2 0 0.6 0 3 S=>NE Exterior Concrete Block-Int Insul Main 4.0999 39 8 8 8 343.8 ft2 0 0.6 0 4 W=>SE Exterior Concrete Block-Int Insul Main 4.0999 59 8 8 8 517.1 ft2 0 0.6 0 5 N=>SW Garage Frame-Wood Main 11 20 0 8 8 173.3 ft2 0.23 0.01 0 6 E=>NW Garage Frame-Wood Main 11 15 4 8 8 132.9 ft2 0.23 0.01 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N=>SW Insulated Main None .4 - 3 6 8 20 ft2 2 N=>SW Wood Main None .46 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered orientation(=>j changed to As Built rotated 225 degrees), / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N=>SW 1 Vinyl Low-E Double Yes 0.34 0.31 31.0 ft2 1 ft 0 in 4 ft 1 in Drapes/blinds Exterior 5 2 N=>SW 1 Vinyl Low-E Double Yes 0.34 0.31 2.5 ft2 3 ft 8 in 0 ft 0 in Drapes/blinds Exterior 5 3 E=>NW 2 Vinyl Low-E Double Yes 0.34 0.31 15.5 ft2 1 ft 0 in 0 ft 9 in Drapes/blinds Exterior 5 4 S=>NE 3 Vinyl Low-E Double Yes 0.34 0.31 62.0 ft2 1 ft 0 in 0 ft 9 in Drapes/biinds Exterior 5 5 S=>NE 3 Metal Low-E Double Yes 0.55 0.34 40.0 ft2 8 ft 0 in 0 ft 8 in Drapes/blinds Exterior 5 6 , W=>SE 4 Vinyl Low-E Double Yes 0.34 0.31 15.5 ft2 1 ft 0 in 0 ft 9 in Drapes/blinds Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 430.0128 ft2 430.0128 ft2 46.6 ft 8.67 ft 0 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000386 1849 101.51 190.9 .2892 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump None HSPF:8.2 28.6 kBtu/hr 1 sys#1 11/9/2017 10:39 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 4 FORM R405-2014 ' COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit None SEER:14 28.6 kBtu/hr 858 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 50 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS / ----Supply- ----Return---- Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 356 ft2 Main 40 ft2 Proposed Qn Main ---cfm 109.7 cfm 0.06 0.60 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: CoolingJan Feb r 1 Mar Apr May X Jun rX�Jul Aug, e Oct Nov Dec Heatin H Jan H Feb [X]Mar Apr l May Jun [ ]Jul l AuSeP Oct Nov Dec Ventin Jan Feb [[[XXX]]]Mar Apr [ May Jun [[[ ]Jul [ Aug Se Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 1 1/9/201 7 10:39 AM EnergyGauge@ USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 4 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the EnergyPerformance Index,the more efficient the home. Zephyrhills, FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul, Exterior R=4.1 1404.00 ft2 b. Frame-Wood,Adjacent R=11.0 306.22 ft 3. Number of units,if multiple family 1 c.N/A R= ftz 4. Number of Bedrooms 4 d.N/A R= ftz 5. Is this a worst case? No 10.Ceiling Types Insulation Area a.Under Attic(Vented) R=30.0 1828.00 ftz 6. Conditioned floor area(ftz) 1828 b.N/A R= ftz 7. Windows" Description Area c.N/A R= ftz a. U-Factor: Dbl,U=0.34 126.50 ftz 11. Ducts R ftz SHGC: SHGC=0.31 a.Sup:Attic, Ret:Main,AH:Main 6 356 b. U-Factor: Dbl,U=0.55 40.00 ftz SHGC: SHGC=0.34 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ftz a.Central Unit 28.6 SEER:14.00 SHGC: d. U-Factor: N/A ftz 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 28.6 HSPF:8.20 Area Weighted Average Overhang Depth: 2.722 ft. Area Weighted Average SHGC: 0.317 8. Floor Types Insulation Area 14.Hot water systems a.Electric Cap:50 gallons a.Slab-On-Grade Edge Insulation R=0.0 1828.00 ftz EF:0.95 b.N/A R= ftz c.N/A R= ftz b. Conservation features None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building V T14E SrgT Construction through the above energy saving features which will be installed (or exceeded) yo in this home before final inspection. Otherwise, a new EPL Display Card will be completed - � - �o �iv`,,,�''�' based on installed Code compliant features. Builder Signature: Date: _, 'Jed 2 Address of New Home: 1�1?r, ��i S�City/FL Zip: coA WIE �c,� *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 11/9/2017 10:39 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-201.4 Florida Department of Business and Professional Regulations Residential Whole Building Performance and Prescriptive Methods ADDRESS: Permit Number: Zephyrhills,FL, MANDATORY REQUIREMENTS See individual code sections for full details. 401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law [Section 553.9085,Florida Statues]requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix C. R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.1 through R402.4.4. O R402.4A Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.The sealing methods between dissimilar materials shall allow for differential expansion and contraction. • R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table 402.4.1.1,as applicable to the method of construction. Where required by the code official,an approved third party shall inspect all components and verify compliance. • R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2,and 3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3.Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. O R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers and outdoor combustion air. O R402.4.3 Fenestration air leakage.Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400 or AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. O R402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential.All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. R403.2.2 Sealing(Mandatory)AII ducts,air handlers,and filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post-construction or rough-in testing below. _ Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either an energy rater certified in accordance with Section 553.99, Florida Statutes,or as authorized by Florida Statutes,to be"substantially leak free"by either of the following: 1. Post-construction test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure.All register boots shall be taped or otherwise sealed during the test. 2. Rough-in test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25Pa)across the system,including the manufacturer's air handler enclosure.All registers shall be taped or otherwise sealed during the test.If the air handler is not installed at the time of the test,total leakage shall be less than or equal to 3 cfm (85 Umin)per 100 square feet(9.29 m2)of conditioned floor area. Exceptions: 1. The total leakage test is not required for ducts and air handlers located entirely within the building envelope. 2. Duct testing is not mandatory for buildings complying by Section R405 of this code. 1 1/9/201 7 1 0:39 AM EnergyGaugeO USA-FlaRes2014 -Section R405.4.1 Com Page 1 of 3 FORM R405-201'4 MANDATORY REQUIREMENTS - (Continued) ❑ R403.2.3 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. ❑ R403.3 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C) or below 55°F(13°C)shall be insulated to a minimum of R-3., R403.3.1 Protection of piping insulation. ❑ R403.4.1 Circulating hot water systems(Mandatory). Circulating hot water systems shall be provided with an automatic or readily accessible manual switch that can turn off the hot-water circulating pump when the system is not in use. ❑ R403.4.3 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3 1/2 inches(89 mm)in the hot water distribution line and cold water line located as close as possible to the storage tank. ❑ R403.4.4 Water heater efficiencies(Mandatory). O R403.4.4.1 Storage water heater temperature controls • R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature setting range shall be from 100°F to 140°F(38°C to 60°C). • R403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s) of combustion types of service water heating systems to be turned off. �0 R403.4.4.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation,Commercial Provisions,for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1. R403.4.4.2.1 Solar water heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors, and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol,Collectors in installed solar water heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and 2. Be installed at an orientation within 45 degrees of true south. ❑ R403.5 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code, Residential or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. ❑ R403.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment. O R403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1.This code does not allow designer safety factors,provisions for future expansion or other factors which affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. • R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load,but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.6,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load. 11/9/2017 10:39 AM EnergyGaugeO USA-FlaRes2014 -Section R405.4.1 Com Page 2 of 3 FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) O R403.6.1.1 Cooling equipment capacity.(continued) The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacture's expanded performance data'shall be used to select cooling-only equipment.This selection shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower cfm provided by the expanded performance data, the design value for entering wet bulb temperature and the design value for entering dry bulb temperature. Design value for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space. Exceptions: 1. Attached single-and multi-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida-registered engineer,in attached single-and multi-family units,the capacity of equipment may be sized in accordance with good design practice. O R403.6.1.2 Heating equipment capacity R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section R403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load. R403.6.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.6.1. R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.6.1. O R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. ❑ R403.7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the Commercial Provisions in lieu of Section R403. ❑ R403.8 Snow melt system controls(Mandatory). Snow and ice-melting systems,supplied through energy service to the building,shall include automatic controls capable of shutting off the system when the pavement temperature is above 55°F,and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F. ❑ R403.9 Swimming pools,inground spas and portable spas(Mandatory). The.energy requirements for residential pools and inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSI/APSP-15.The energy . requirements for portable spas shall be in accordance with ANSI/APSP-14. O R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on-off switch that is mounted outside the heater to allow shutting off the heater without adjusting the thermostat setting. R403.9.1.1 Gas and oil-fired pool and spa heaters. All gas-and oil-fired pool and space heaters shall have a minimum thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013 when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights. R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. O R403.9.2 Time switches. Time switches or other control method that can automatically turn off and on heaters and pumps according to a preset schedule shall be installed on all heaters and pumps. Heaters,pumps and motors that have built in timers shall be deemed in compliance with this equipment. Exceptions: • 1. Where public health standards require 24-hour pump operations. 2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation. O R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Outdoor pools deriving over 70 percent of the energy for heating from site-recovered energy,such as a heat pump or solar energy source computed over an operating season. ❑ RR404.1 Lighting equipment(Mandatory). A minimum of 75 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps. Exception: Low-voltage lighting shall not be required to utilize high-efficacy lamps. O R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights ❑ R405.2 Performance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R-6. O R405.2.1 Performance ONLY. Ceilings shall have minimum insulation of R-19.Where single assemby of the exposed deck and beam type or concrete deck roofs do not have sufficent space, R-10 is allowed. 11/9/2017 10:39 AM EnergyGaugeO USA-FlaRes2014 -Section R405.4.1 Com Page 3 of 3 FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Cali 1828 Elev D Builder Name: DRH Express Homes Street: Permit Office: City,State,Zip: Zephyrhills, FL, Permit Number: Owner: Jurisdiction: Design Location: FL,Tampa COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and d the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/doorjambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations,and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity Maces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated,and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 11/9/2017 10:39 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Envelope Leakage Test Report Prescriptive and Performance Method Project Name: Cali 1828 Elev D Builder Name: DRH Express Homes Street: Permit Office: City,State,Zip: Zephyrhills,FL, Permit Number: Design Location: FL',Tampa Jurisdiction: Cond. Floor Area:: 1828 sq.ft. Cond.Volume: 15849 cu ft. Envelope Leakage Test Results Leakage Characteristics Regression Data: C: n: R: CFM(50): Single or Multi Point Test Data HOUSE PRESSURE FLOW: ELA: 1 Pa cfm EgLA: 2 Pa cfm ACH: 3 Pa cfm ACH(50): 4 Pa cfm 5 Pa cfm SLA: 6 Pa cfm R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2,3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3.Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. I hereby certify that the above envelope leakage Where required by the code official, 01,V"E S�A� performance results demonstrate compliance testing shall be conducted by an ,, a.,{, with Florida Energy Code requirements in approved third party. A written accordance with Section R402.4.1.2. report of the results of the test shall be signed by the third party .......;4( . C7 . conducting the test and provided to SIGNATURE: the code official. PRINTED NAME: BUILDING OFFICIAL: DATE: DATE: 11/9/2017 10:40 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014'Duct Leakage Test Report Performance Method FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Form R405 Duct Leakage Test Report Performance Method Project Name: Cali 1828 Elev D Builder Name: DRH Express Homes Street: Permit Office: City,State,Zip: Zephyrhills, FL, Permit Number: Design Location: FL,Tampa Jurisdiction: Duct Test Time: Post Construction Duct Leakage Test Results CFM25 Duct Leakage Test Values Line System Outside Duct Leakage 1 System 1 cfm25(Out) 2 System 2 cfm25(Out) 3 System 3 cfm25(Out) 4 System 4 cfm25(Out) 5 Total House Sum lines 1-4 Duct System Leakage Divide by (Total Conditioned Floor Area) (Qn,Out) I certify the tested duct leakage to outside, Qn, is VE not greater than the proposed duct leakage Qn Duct tightness shall be verified by 0 SrA�� specified on Form R405-2014. testing to Section 803 of the RESNET , , �T 0,� Standards by an energy rater certified in accordance with Section 553.99, Florida Statutes. SIGNATURE: IPIN' ' * g 4� PRINTED NAME: c4D WE' DATE: BUILDING OFFICIAL: DATE: 11/9/2017 10:40 AM EnergyGauge@ USA-FlaRes2014 -Section R405.4.1 Compliant S Page 1 of 1 Manual S Compliance Report Date:+-wrightsoftv p p Date: Oct 10,2014 Entire House By: Progressive Air Systems, Inc 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 Project • • For: DR Horton/Express Lot 17 Blk 6 Silverado Ranch, Zephyrhills, FL Cooling-Equipment Design Conditions Outdoor design DB: 91.2°F Sensible gain: 21821 Btuh Entering coil DB: 75.4°F Outdoor design WB: 77.1 OF Latent gain: 2966 Btuh Entering coil WB: 62.7°F Indoor design DB: 75.0°F Total gain: 24787 Btuh Indoor RH: 50% Estimated airflow: 1000 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB030****A+FB4CNP030 Actual airflow: 1000 cfm N Sensible capacity: 23270 Btuh 107%of load Latent capacity: 3914 Btuh 132%of load Total capacity: 27184 Btuh 110%of load SHR: 86% • • • Design Conditions Outdoor design DB: 40.0°F Heat loss: 21100. Btuh Entering coil DB: 69.8°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB030****A+FB4CNP030 Actual airflow: 1000 cfm Output capacity: 25604 Btuh 121%of load Capacity balance: 32 OF Supplemental heat required: 0 Btuh Economic balance: -99 OF Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 1000 cfm Output capacity: 6.6 kW 107%of load Temp. rise: 20 OF Meets are all requirements of ACCA Manual S. wri htsoft$ 2017-Nov-09 10:41:24 g Right-Suite®Universal 2017 17.0.21 RSU25554 Page 1 ..on\Wrightsoft Files\Fxpress homes\Cali 4EBB.rup Calc=MJ8 House faces:SW Load Short Form Job: -f + wrightsofte Date: Oct 10,2014 Entire House By: Progressive Air Systems, Inc 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 .License:CAC033669 Project • • For: DR Horton/Express Lot 17 Blk 6 Silverado Ranch, Zephyrhills, FL Design InfDrmation Htg Cig. Infiltration Outside db(OF) 40 91 Method Simplified Inside db(OF) 70 75 Construction quality Semi-tight Design TD (OF) 30 -16 Fireplaces 0 Daily range - L Inside humidity (%) 50 50 Moisture difference(gr/lb) 26 54 HEATING EQUIPMENT COOLING EQUIPMENT Make Carrier Make' Carrier Trade CARRIER Trade CARRIER Model CH14NB030****A Cond CH14NB030****A AHRI ref Coil FB4CNP030 AHRI ref Efficiency 8 HSPF Efficiency 11.5 EER, 14 SEER Heating input Sensible cooling 22500 Btuh Heating output 29600 Btuh @ 47°F Latent cooling 7500 Btuh Temperature rise 27 OF Total cooling 30000 Btuh Actual air flow 1000 cfm Actual air flow 1000 cfm Air flow factor 0.047 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.88 Capacity balance point=32 OF Backup: Input= 7 kW, Output= 22477 Btuh, 100 AFUE ROOM NAME Area Htg load Cig load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) M bed 194 3196 3505 151 161 living room 270 2891 4027 137 185 kitchen/dining 349 4292 5695 203 261 bed3 155 1420 1079 67 49 bath2 55 604 278 29 13 bed2 168 3411 2869 162 131 we 21 24 35 1 2 M bath 114 1276 652 60 30 M wic 66 77 112 4 5 laundry 39 45 668 2 31 bed4/den opt 169 1866 1320 88 60 A/C closet 19 181 114 9 5 foyer 200 1817 1468 86 67 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wri 17tSOirt` 2017-Nov-0910:41:24 ,.� 9 Right-Suite®Universal 2017 17.0.21 RSU25554 Page 1 ACCK ...on\Wrightsoft Files\Express homes\Cali 4EBB.rup Calc=MJB House faces:SW Entire House d 1820 21100 21821 1000 1000 Other equip loads 0 0 Equip. Qa 1.00 RSM 21821 Latent cooling 2966 TOTALS 1820 21100 24787 1000 1000 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Al- wri htsoft� 2017-Nov-0910:41:24 1, '� 9 Right-Suite®Universal 2017 17.0.21 RSU25554 Page 2 �+CwP% ...on\Wrightsoft Files\Express homes\Cali 4EBB.rup Cale=MJ8 House faces:SW Project Summary Job: wrightsoft® Date: Oct 10,2014 Entire House By: Progressive Air Systems, Inc 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815.3399 License:CAGO33669 Project Information For: DR Horton/Express Lot 17 Blk 6 Silverado Ranch, Zephyrhills, FL Notes: Design InformatiOn Weather: Tampa Intl AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 40 OF Outside db 91 OF Inside db 70 OF Inside db 75 OF Design TD 30 OF Design TD 16 OF Daily range L Relative humidity 50 % Moisture difference 54 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 17539 Btuh Structure 17223 Btuh Ducts 3561 Btuh Ducts 4598 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 21100 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 21821 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 2360 Btuh Ducts 606 Btuh Central vent(0 cfm) 0 Btuh Heatin Cooling (none)Area(ft2 1�N 1820 Equipment latent load 2966 Btuh Volume(ft3) 16012 16012 Air changes/hour 0.26 - 0.14 Equipment total load 24787 Btuh Equiv.AVF(cfm) 69 37 Req. total capacity at 0.75 SHR 2.4 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER Trade CARRIER Model CH14NB030****A Cond CH14NB030****A AHRI ref Coil FB4CNP030 AHRI ref Efficiency 8 HSPF Efficiency 11.5 EER, 14 SEER Heating input Sensible cooling 22500 Btuh Heating output 29600 Btuh Ca-) 47OF Latent cooling 7500 Btuh Temperature rise 27 OF Total cooling 30000 Btuh Actual air flow 1000 cfm Actual air flow 1000 cfm Air flow factor 0.047 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio - 0.88 Capacity balance point=32 OF Backup: Input=7 KVV, Output=22477 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft- Right-Suite®Universal 2017 17.0.21 RSU25554 2017-Nov-09 10:41:24 ...on\Wdghtsoft Files\Express hornes\Cali 4EBB,rup Calc_�MJ8 House faces:SW Page 1 4 FORM R405-2014 RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST Florida Department of Business and Professional Regulation Simulated Performance Alternative (Performance) Method Applications for compliance with the 2014 Florida Building Code, Energy Conservation via the residential Simulated Performance method shall include ❑ This checklist ❑ A Form R405 report that documents that the Proposed Design complies with Section R405.3 of the Florida Energy Code. This form shall include a summary page indicating home address, a-ratio and the pass or fail status along with summary areas and types of components, whether the home was simulated as a worst-case orientation, name and version of the compliance software tool, name of individual completing the compliance report(1 page)and an input summary checklist that can be used for field verification (usually 4 pages/may be greater). ❑ Energy Performance Level(EPL) Display Card(one page) ❑ Mandatory Requirements(three pages) Required prior to CO for the Performance Method: ❑ Air Barrier and Insulation Inspection Component Criteria checklist(Table R402.4.1.1 - one page) ❑ A completed Envelope Leakage Test Report(usually one page) ❑ If Form R405 duct leakage type indicates anything other than "default leakage", then a completed Form R405 Duct Leakage Test Report(usually one page) EnergyGauge@-USRCZB v5.1 1 1/9/201 7 9:57:35 AM Page 1 of 1 8 Run: 920/1 do 9/ 0 Scheduled Building Inspections by Date Schedule Date 9/21/18 thru 9/21/18 Page: 1 KALVIN SWITZER Date Time Req Permit Address Inspection By 0/21/2018 12:OOAM 20214 67 DAIRY RD FINAL KS BAHR'S PROPANE GAS 7C, INC. MECHANICAL A/ ANGE OUT 2 TON 9/21/2018 12:OOAM 20188 6504 WAGON TRAIL ST PLUMBING FINAL A /( KS PIPE PROS INC � L11 L IRRIGATION INSTALLATION IRRIGATION CONNECT ONLY***************** 9/21/2018 12:OOAM❑ 20242 6512 WAGON T L PLUMBING FINAL �7"L� KS PIPE PROS INC IRRIGATION IRRIGATION C N ECT ONLY************ 9/21/2018 12:OOAM❑ 20241 6500 WAGON T S PLUMBING FINAL KS PIPE PROS INC IRRIGATION IRRIGATION CO jq T ONLY******************** 9/21/2018 12:OOAM❑ 201.53 5537 12TH ST FINAL KS BAHR'S PROPANE GAS &A/C, INC. MECHANICAL A/C CHANGE OUT 2 TON 9/21/2018 12:OOAM❑ 20073 39218 5T AV FINAL KS BAHR'S PROPANE GAS &A/C, INC. MECHANICAL _ A/C CHAIN OUT 3 TON /J C79/21/2018--12:00AM 1-9708- J`6500 WAGO TF ANGIL ST PLUMBING FINAL KS N6 R HORTON INC fEW SINGLE FAMILY DWELLING CONSTRU SI E FAMILY 3,088 SQ FT !9/21/2018 12:OOAM 19708 6500 WAGON TRAIL ST ELECTRICAL FINAL KS R R HORTON INC j-NEW-SINGLE FAMILY DWELLING-- )CONSTRUCT SINGLE FAMILY 3,088 SQ FT 9/217201-8= 1-2:OOAM— 19709 04 WAGON TRAIL ST Bl11LDING-FINAL="A'> KS D�R HORTON INC results for test in office NEW SINGLE FAMILY DWELLING CONSTRUCT SINGLE FAMILY 2,362 SQ FT 9/21/2018 12:OOAM❑ 19709 6504 WAGO TRAIL "T PLUMBING FINAL / KS DR HORTON INC " NEW SINGLE FAMILY DWELLING CONSTRU T GLE FAMILY 2,362 SQ FT 9/2i1/2018 12:OOAM❑ 19709 6504 WAGO V IL ST ELECTRICAL FINAL KS D R HORTON INC NEW SINGLE=FAMILY-DINELGING_� CONSTRU SINGLE FAMILY 2,362 SQ FT 9121/2018 1ROOAM 19588 6597 WAGON IL T BUILDIN LFFINAL KS Off HORTON INC test results Sn" a e NEW SINGLE FAMILY DWELLING CONSTRUCTS LE FAMILY HOME 2,362 SQ FT 9'/21/2018 12:OOAM r 19588 6597 WAGO IL ST FINAL MECHANICAL KS D R HORTON INC (� EW SINGLE FAMILY DWELLING CONSTRUCT SINGLE FAMILY HOME 2,362 SQ FT 9/21,/201"8=T2--00AM-- 1:9708=--6500=WAGON TRAIL ST FINAL MECHANICAL KS D R HORTON INC NEW SINGLE FAMILY DWELLING CONSTRUCT SINGLE FAMILY 3,088 SQ FT 9/217201-8-=-11-2OOAM❑=--1-9588=- 6597 WAGON TRAIL ST PLUMBING FINAL © , KS )D R HORTON INC NEW SINGLE FAMILY DWELLING K- NST15UCT SINGLE FAMILY HOME 2,362 SQ FT 0. 1"9/21/2018 12:OOAMO 19588 65 GON TRAIL ST ELECTRICAL FINAL KS R HORTON INC NEW SINGLE FAMILY DWELLING C INSTRUCT SINGLE FAMILY HOME 2,362 SQ FT Run: 9/20/18 2 20/18 Scheduled Building Inspections by Date Schedule Date 9/21/18 thru 9/21/18 Page: 2 KALVIN SWITZER Date Time,_-Req_tP_6 it Address Inspection By 9%2T/201=8=-12.00AM 590 6517 WAGON TRAIL ST ELECTRICAL FINAL KS °R D HORTON INC IV° EW SINGLE FAMILY DWELL!PJG CONSTRUCT SINGLE FAMILY HOME 2,362 SQ FT 9/21/2018 12:OOAM 1 90 6517 WAGON TRAIL ST FINAL MECHANICAL C� KS D R HORTON INC NEW SINGLE FAMILY DW LLING CONSTRUCT SINGLE FAMILY HOME 2,362 SQ FT i9/21/2018 12:OOAMLV 19590 6517 WAGON TRAIL ST BUILDING-FINAL KS b R HORTO.N-INC - — _.; test results in office I EW-SINGLEFANIILY�DWELLING CONSTRUCT SINGLE FAMILY HOME 2,362 SQ FT 012142018"LA-2 OOAM 19711 6512 WAGON TRAIL ST BUIL-DIN&FINAL .P— KS ID R HORTON INC test results in office NEW SINGLE FAMILY DWELLING CONSTRUCT SINGLE FAMILY 2,238 SQ FT i 9/21/2018 12:OOAMH 19711 6512 WAGON TRAIL ST FINAL MECHANICAL KS ID R HORTON INC �VEW-SINGLE-FAMIL-Y DWELLING CONSTRUCT SINGLE FAMILY 2,238 SQ FT 02//2018 12:OOAM❑ 19708 6500 WAGON TRAIL ST BUILDING FINAL KS 6 4.n D R HORTON INC test results in office NEW SINGLE FAMILY DWELLING CONSTRUCT SINGLE FAMILY 3,088 SQ FT 9724/2018--1 -�2:OOAM -`-1-9711 6512 WAGON TRAIL ST ELECTRICAL FINAL KS D R HORTON INC NEW SINGLE FAMILY DWELLING CONSTRUCT SINGLE FAMILY 2,238 SQ FT 9/21/2018 12:OOAM❑ 19711 6512 WAGON TRAIL ST PLUMBING FINAL/ KS crl-I•b D R HORTON INC NEW-SINGLE�FAMILY/DWE LING CONSTRUCT SINGLE FAMILY 2,238 SQ FT 9/21/2018-J2:OOAM=':� �19590 6517 WAGON TRAIL ST PLUMBING FINAL KS D R HORTON INC NEW SINGLE FAMILY DWE LING CONSTRUCT SINGLE FAMILY HOME 2,362 SQ FT I'f� L:l'-19727=` 3076 KRESTERBROOKE LANE PLUMBING FINAL KS ��LENNAR HOMES LLC NEW SINGLE FAMILY D ELLING CONS UCT SINGLE FAMILY 2,005 SQ FT 9/21/2018 12:OOAM 19727 3076 KRE TE ROOKE LANE ELECTRICAL FINAL KS LENNAR HOMES LLC NEW SINGLE FAMILY D LLING CONS T SINGLE FAMILY 2,005 SQ FT i9/21/2018 12:OOAMEV 19727 3076 KR STE BROOKE LANE FINAL MECHANICAL KS LENNAR HOMES LLC 'NEW SINGLE FAMILY DW LLING CONST UCT SINGLE FAMILY 2,005 SQ FT l 9/21/2018 12:06AM 19727 3076 KRESTERBROOKE LANE BUILDING FINAL KS LENNAR_HOMES=LLC REPORT IN OFFICE JNEW-SINGLE FAMILY-DW LL-IN& CONSTRUCT SINGLE FAMILY 2,005 SQ FT 9/21/2018 12:0OAM -- _1.9 09_�_ 6504-WAGON-TRAIL-ST. ==_ _-MECHANICAL FINAL KS D R HORTON INC - _ NEW SINGLE FAMILY DW LING CONSTRUCT SINGLE FAMILY 2,362 SQ FT 9/21/2018 12:OOAM 18883 5627 20TH S DRIVEWAY KS BACK CONSTRUCTION DRIVEWAY CONSTRU EW DRIVEWAY 36 X 19 FOR ADDITION 1x reinstate Number of inspections printed: _3a- 3 1 q8 -2- Jacqueline Boges From: MWConstruction<Florida.support@duke-energy.com> Sent: Friday, September 21, 2018 3:09 PM To: Jacqueline Boges Subject: Duke Energy[T2018092101 PSS010Z10433639] Dear Ms. Boges, Thank you for contacting Duke Energy Florida. The safety inspection information for 39450 South Ave, Hangar 1 unit 6 and Hangar 4 unit 7 has been received and posted. Best regards, Khalea Duke Energy Senior Associate ****Please do not reply back to this e-mail directly. Please reply to NEWCONSTRUCTION@DUKE-ENERGY.COM**** i Jacqueline Boges From: Jacqueline Boges Sent: Friday, September 21, 2018 2:58 PM To: Duke Energy(floridamunicipalities@duke-energy.com) Cc: Lucy Huber Subject: power release for hangars Hello, Jackie, here in the City of Zephyrhills and I am requesting power to be released for couple of our hangars located at 39450 South Ave Hangar 1 unit 6 Hangar 4 unit 7 We do not have permit numbers because the inspection was only a safety done.Acknowledgement of this email as indication inspection given as this email will be part of the file . Thank you have a great weekend. daeklc Boges --- 813-780-0020 ext 3513 "A rule I have had for years is:to treat the Lord Jesus Christ as a personal friend. His is not a creed,a mere doctrine, but it is He Himself we have." Dwight L. Moody Florida has a very broad public records law. Electronic communications regarding most City of Zephyrhills business are public records and available upon request. Your e-mail communications may therefore be subject to public disclosure. If you received this message in error, please do not read, forward, copy, etc. and delete immediately. From: Lucy Huber Sent:Wednesday,September 19, 201812:47 PM To:Jacqueline Boges<jboges@ci.zephyrhills.fl.us> Subject: Hangar 1 Unit 6 Hi Jackie, Can someone come over and check hangar 1 Unit 6 and Hangar 4 Unit 7 for power? Thanks! 0 Jacqueline Boges From: Lucy Huber Sent: Wednesday, September 19, 2018 12:47 PM To: Jacqueline Boges Subject: Hangar 1 Unit 6 Hi Jackie, Can someone come over and check hangar 1 Unit 6 and Hangar 4 Unit 7 for power? Thanks! O zw# qat i City of Zephyrhills Municipal Airport .Exeudive OUmiiLaftative 0g.6sistaat 873-780-0030 (office) 873-780-0032 (0Fax) www.ci.zephyrhiIIS.fl.us { ONE KJ�NDaWOR6 �. soMeoae„.6 o,ntire day i 1 • 5335 - 8TH STREET (813)780-0020 CERTIFICATE OF OCCUPANCY Address: 6504 WAGON TRAIL ST Owner: DR HORTON INC ZEPHYRHILLS, FL. 12602 TELECOM DR Subdiv: SILVERADO TAMPA FL 33637-0935 Parcel: 05-26-21-0080-00600-0170 Work Type: 103-NEW CONST DUPLEX 2-UNIT Construction Type: NOT APPLICABLE ❑ Sprinklers Use Classification: NOT APPLICABLE Permit Number: 19709 Date: 9/21/2018 Gt 0 ISSUED BUILDI OFFICIAL : WATER MUST BE CHANGED OVER WITHIN 10 DAYS OF ISSUANCE GARBAGE DEPOSIT MUST BE APPLIED FOR PRIOR TO ISSUANCE FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Envelope Leakage Test Report Prescriptive and Performance Method Project Name: SILVERADO Builder Name: D R HORTON Street: 6504 Wagon Trail St Permit Office: ci�q ct I�0 F!"1,/X15 City,State,Zip: Zephyrhills,FL 33541 Permit Number: Design Location: 6504 Wagon Trail St(Lot 17) Jurisdiction: Cond.Floor Area: 1828 Cond.Volume: 15849 V Envelope Leakage Test Results Leakage Characteristics Regression Data: C: n: R: CFM(50): 1217 Single or Multi Point Test Data ELA: 67 HOUSE PRESSURE FLOW: 1 50 Pa 1217 cfm EgLA: 158 ACH: 4.61 2 0 Pa 0 cfm SLA: .04 3 0 Pa 0 cfm ACH(50)*: 4.61 4 0 Pa 0 cfm *For prescriptive projects,tested leakage must be7 5 0 Pa 0 cfm ACH(50). For performance projects, tested leakage must be—the ACH(50)shown on Form R405-2014 6 Pa cfm for this project. R402.4.1.2 Testing.The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zones 1 and 2.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statutes or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration 3.Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. I hereby certify that the above envelope leakage performance results demonstrate compliance with Florida Energy Code requirements in accordance with Section R402.4.1.2. Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statutes 04�tifiSTgT6 or individuals licensed as set forth in Section AV , `_ oe 489.105(3)(f),(g),or(i)or an approved third party.A written report of the results of the test shall be signed Di9itally signed by Michael by the third party conducting the test and provided to (�'r1,1 ? Silberstein the code official. a Date:2018.09.1914:19:55 EDT CN=Michael Silberstein,O=TopBuild f'1 G, V Home Services,OU, Op we EMAILADDRES S=Mich ael.Si Iberstei Signature: n@topbuild.com,C=US Printed Name: Michael Silberstein BUILDING OFFICIAL: Date: 09/19/2018 DATE: Thank you for allowing TopBuild the opportunity to provide the above services for you.Please feel free to contact me with any questions. 10/25/2017 396353