Loading...
HomeMy WebLinkAbout18-19711 CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 19711 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL PERMIT INFORMATION- - LOCATION.INFORMATION Permit#:19711 Issued. 5/29/2018 Address: 6512 WAGON TRAIL ST Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 252,110.70 Total Fees: 11,331.69 Subdivision: SILVERADO Amount Paid: 11,331.69 Date Paid: 5/29/2018 Parcel Number: 05-26-21-0080-00600-0160 CONTRACTOR INFORMATION OWNER INFORMATION Name: DR HORTON INC Name: DR HORTON INC Addr: 12602 TELECOM DR Address: 12602 TELECOM DR TAMPA, FL. 33637 TAMPA FL 33637-0935 Phone: Lic: Phone: 813-549-1968 Work Desc: CONSTRUCT SINGLE FAMILY 2,238 SQ FT APPLICATION FEES. BUILDING FEE 1,045.93 ELECTRICAL FEE 213.08 PLUMBING FEE 142.05 MECHANICAL FEE 99.44 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE-sfr/100% 4,828.00 SCHOOL IMPACT FEE-sfr/1% 48.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32 t Inspections Required FOOTER 2ND ROUGH PLUMB MISC INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans, Specifications and Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. C9 -122���� &-- f"�* CONTRACTORS SIGNATURE PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER e13-780-0020 City of Zephyrhilis Permit Application FaX a1a-7e°0021 Building Department Date Received Phone Contact for Permitting - r Ownerr N m�. K 0.c, r� r-� �= Owner Phone Number S Ll 4c 9 6, Owner's Address �rri�ta ��'j e �" '�' p'r ! Owner Phone Number Fee Simple Titleholder Name r 1 Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS {{1} _u-Trn 3� LOT# .SUBDIVISION U c-- �4 PARCEL ID# �•� �r/%` la"�c f 'TU�C� " (OBTAINED FROM PROPERTY TAX NOTICE) ; WORK PROPOSED �JNEW CONSTR ADDJALT SIGN DEMOLISH : 8 "INSTALL 8 REPAIR PROPOSED USE 0'' SFR C] COMM OTHER' TYPE OF CONSTRUCTION . i �� BLOCK 0 FRAME STEEL 0 DESCRIPTION OF WORK ��t•. �� .�' � ,� �l�a'�,^� `� 1`'•-lc c� Z��:'�-�-e 1 --��c�-"�-t. BUILDING SIZE. SO FOOTAGE HEIGHT* -_� f-1-1 lei•�tA�>ri<"�"t�1TTlr`T"i—IYT B�Y Y^I�eTt�9—f�P G�" '�r'Y-7^i�rP"P"•����'rY"6'.Ir"[�r'4—G P�4�0"�� 3'��E 9—A�➢� =BUI'LDING $ VALUATION OF TOTAL CONSTRUCTION =ELECTRICAL �6, Q� AMP SERVICE PROGRESS ENERGY C] W.R.E.C. =PLUMBiNG 7 11 �MECHANiCAL $ VALUATION OF MECHANICAL INSTALLATION t` =GAS ROOFING SPECIALTY OTHER FINISHED FLOOR ELEVATIONS f FLOOD ZONE AREA OYES NO -1-4-1--1-l-i-l--l-F--!•-8-1-(I-&-Fl--l- UJI-C-•$--1-1-4-1--T-$•-l-Iri�C-zl-3-l-l--H-'�u' BUILDER COMPANY � � SIGNATURE t�� REGISTERED Y/ N FEE CURREN Y/N Address �r 1 l� �>!'<cS.�+r ) i�� - License# '-B ..F_L.ECTRICIA(V COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address 0° 57 -'�P 'O�L� r r License# �� �..d z 1� n PLUMBER COMPANY .SIGNATURE ' REGISTERED Y/ N FEE CURREN Y/N Address r�r ?� f fi+ �t� tt r s? License# a FC 0 MECHANICAL COMPANYA`�i '� �� d " SIGNATURE f a� '���' ^ _'- REGISTERED Yfi/ N FEE CURREN Y/N Address � K� f Fr f �a�. f2ac u a "ter. yJ 1 r � License# I C111C C)3�51 4`' 16 -F.i_ _ -r-_- j7lf f�� ��F,,,e/' OTHER COMPANY f•'r� _ �-� SIGNATURE pp REGISTERED Y/ N FEE CURREN Y/N Address I/ E„cr �J License# RESIDENTIAL Attach (2) Plot Plans; (2)sets of Building Plans; (1)set of Energy Forms; R-O-W Permit,for new construction, Minimum ten (10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt.Fence installed, Sanitary Facilities&1 dumpster;Site Work'Permit for subdivislons/large projects COMMERCIAL Attach (2)complete sets of Building Plans plus a Life Safety Page; (1)set of Energy Forms. R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.Ail commercial requirements must meet compliance SIGN PERMIT Attach (2)sets of Engineered Plans. ""PROPERTY-SURVEY required for ail NEW construction. Directions: Fill out application completely. Owner Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (AIC upgrades over$7500) * Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same )VER THE COUNTER PERMITTING (copy of contract required) 1'eroofs if shingles - Sewers C;ervice Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..heeds ROW . ` . NOTICE(]F DEED RESTRICTIONS: The undersigned understandsthattkispermit may b su bject . which may ba more rea�iodxethan County nagu|abon�. The undem|gnedassumes responsibility �~--�~~`^~� oppUoab|adeed resthotona. . —~ —' UNLICENSED CONTRACTORS AND CONTBACTOR 8ESPO*N8(B|UT|ES: If has hired � n ontnsck or contractors toundedake work, they may be required tobe |ioanoadin accordance vhhstate and-local regu|adona. If'-the contractor is not-licensed as required by |ew, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended.contractor.are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division--Lioene|ng Section at727-847- � ' 8000. Furthermore, if the owner has hired a contractor or contractors., he is advised to have the contractor(s) sign' portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign ethe contractor, that may be an indication that heia not properly licensed and is not antidedto p.armitting privileges.in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned.understands that Transportation |rnpoot Fees and Recourse Recovery Fees may apply to the construction of new buUd|ngs, change of use in existing buUd/ngn, or exiJano|on of existing bui|dinga, as specified in Pasco County Ordinance number 89-07 and 90'87. as amended. The undersigned also.undorntandn, that such feas, an may be due, will be identified cfthetirna of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees.must be paid prior to receiving a "certificate of occupancy" or final pnvvnr release. If the project does not involve u certificate of occupancy or . final power re|easo, the fees must be paid prior to permit issuance. Furthermore, if Pasno-CountyVVeder/Smvver Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CQNSTRUCTKO0 LIEN LAW (Chapter 713, Florida Statutes, aoamnmnded): |f valuation ofw4orkio $2,5UO.8Oor more, | certify that |, the app|icant, have been provided with a copy of the 'Florida Construction, Lien Law—Homeowner's Protection Guide" prepared by the Florida Department ofAgriou|ture-and Consumer Affairs. If the.applicant is someone ` other than the "owner". \ certify that | have obtained a copy of the above described document and promise in good faith to deliver Mbo the''nwner^ prior hocommencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: | certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and. land development. Application is hereby made to obtain a pe'mit to do work and installation as indicated. | certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating conetruol\on. County and City. codes,' zoning [egu|ationa, and'land development regulations,in the jurisdiction. | also uortifvthat | understand that the regulations of�other government agenc\esmay apply tO the intended xvo/k. and that |t )s rnyr'apona|biUtytoidentUvvvhst actions | must take toba |nCornpUan�ca. Such agencies |ndudabut are not|\n0itedkr ' Department of' Environmental P rote nt|on'Cypress Buyheade, Wetland Areas and Environmentally Sensitive Lands. VVutmnlNaetovvaterTreatmon1. ' Southwest Florida Water Management D\ntrint4We||s, Cypress. BayheaUs, Wetland Areas. Altering Watercourses. ' - Army Corps ofEnginears-GaawaUs. Docks, Navigable Waterways. - Department of Health & Rehabilitative Sen/iueo/Env\runmental Health Unit'VVeUs, VVea1ewe1ar Traatment.I SeptioTanka. - Us-EmvinonmentalProtection Agenuy'Aabe�toeabatement. - Federal Aviation /\uthohty-Runwaya. \ understand that the following restrictions apply to the use cf fill: - Use of fill io not allowed in Flood Zone "V" unless expressly parnn\Kad` ` If the fill material is to be used in Flood Zone "A'. it is understood that o drainage plan addressing a ' compensating volume" will be submitted at time of permitting which is prepared by a prqfoabiona\ anginaoi - licensed by the State of Florida. - If the fill material is to be used in Flood Zone "N' in connectionwith a.permitted building using stem wail construction, ) certify that fill will be used only to fill the area within the stem wall. ' If fill material is to be used in any area, | certify that use of such fill will not adversely affect adjacent properties. If 'use of fill is found to adversely affect adjacent properties, the owner may be cited for violating ' the conditions of the building permit issued under the attached permit application, for lots less than one /1\ acre which are elevated by fill, an engineered drainage plan is raqu|[ed. _ If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions Set forth in this affidavit prior to commencing construction. | understand that a separate permit may be.required for electrical work,' p|umbing, eigna, wells, poo|m, air conditioning, gas,,or other inaLaUo1\mns not specifically included in the application. A permit issued shall be consffued to be a license to proceed with-the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors-in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit |seuanue, or if work authorized by thnperrnit|ssuspendedorabandoned0zrapedod^ofu\x (G) nnonthsaftarthut\mpthaWorkiaoonnnoenoed. An extension may be requested, in vvrUing, from the Building Official for a period not to axnaod ninety /SO\ days and will demonstrate � justifiable cause for the extension. If work ceases for ninety (90) consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF C(]K8K8ENCEK8E0T MAY RESULT, IN YOUR.' PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY' IF YOU INTEND TO OBTAIN F\YJANC1NG. CONSULTWITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF- ru/n.D*uun*/ (ru / /' uo ` OWNER OR AGENT CONTRACTOR Subscribedand Sw n to(or affirmed)before me this Subscribed and sworn to(or affirmed) before*me this by \A/hr)I 'are per mnally-Imawn to me or has/have,produced vvbois/are p.ersonallyknown to me or has/have produced as identification. ` as Identification. Notary Public ' Notary,""= - . Commission No. Commission No. n ' ' Name— of Notary typed,_ ----- stamped_ _ _e of Notary typed,printed or stamped-0 0 No Notary Public State of Florida ` . OF Expires 1?121f2020 INSTR#2Oi8O84889OR BK9727 PG331 3 Page 1 of I 05/21/2018Rcpt:1958802 Rec:I O00 DS:0.00 IT:0.00 PauCa s. bwei[6 Ph-D, Pasco County CLclrk&COmPtrOCCer 4 Permit No. Parcel-ID No 0)5—Z6- NOTICE OF COMMENCEMENT State of Florida County of Pas THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in aiccordance with Chapter 713,Florida Statutes, the following information is provided in this Notice of Commencement C�+ I ( —Mt 1. Description of Property. Parcel Identification No. 1 x4/, & <Qlv�aadr) - (2 U 9Q6 F/_33_ Street Address: (�o 6 A k IV, 2�e 12 A RS 2. General Description of Improvement New Single Family Residence 1 3. Owner Information or Lessee information if the Lessee contracted for the improvement: D.R. Horton, Inc Name 1?602 Telemm Drive Tqmnn 33637- -- F1 Address city State Interest in Property: FPeSjMP1e Name of Fee Simple Titleholder. (if different from Owner listed above) Address city state 4. Contractor. --D.-R. Horton, InQ Name 126Q2 Telecom Drive T;;mns 33637 FL Address city State Contractor's Telephone No.: 5. Surety: N/A Name Address city State Amount of Bond: S N/A Telephone No- 6. Lender. NIA Name ,Address city State Lender's Telephone No.: 7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)M,Florida Statutes: David Gude Name 12602 Telecom Drive Tamna 33637 FL Address city State Telephone Number of Designated Person: 813-740-9720. 8. In addition to himself,the owner designates NIA I of to receive a copy of the Lienor's Notice as pro ded in Section 713.13(1)(b),Florida Statutes. Telephone Number of Person or Entity Designated by Owner. Iii 9. Expiration date of Notice of Commencement(the expiration date may not be before the completion of construction and final payment to the contractor,but will be one year from the date of recording unless a different date is specified): WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A 'NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDINGrOUR NOTICE OF COMMENCEMENT. Under penalty of perjury,I declare that I have read the foregoing notice of commencement and that the facts stated therein are true to the best of my knowledge and belief. STATE OF FLORIDA COUNTY OF PASCO IVA gs jiu."AT Sign uri-of Owner or Lessee,or Owner's or Lessees Authorized Offic�ti/DlrectortPartner/Manager Assistant Secretarv/D. Horton. Inc Signatory's TitlelOffice The foregoing instrument was acknowledged before me this day of AQ ,Z ,20/ by 70 as_—Assistant Secretary (typeof auto e.g.,officer,trustee,attorney in fact)for D.R. Horton. Inc (name of party n beh I om instru ant was executed). Personally Known R OR Produced Identification[I Notary Signature. _77,417T, Type of Identification Produced Name(Print) Asy pp, Notary Public State of Florida Michelle Moyes My Comm lesion GO 067321 %10,w Expires 12121/2020 wpdatalbos/noticecommencement_pc053048 PLOT PLAN DESCRIPTION:(AS FURNISHED) LOT 16, BLOCK 6, SILVERADO RANCH SUBDIVISION PHASE 6, 8 & 9A AS RECORDED IN PLAT BOOK 75, PAGE(S) 75-80, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. Curve Table Curve $ Length Radius Delta Chord Bearing Chord - CI 39.92' 55.00' 41*35'13" N74'02'13'W 39.05' ' C2 26.27' 100.OD' 15.02'58- N87-18.20•W 26.19' _ j05.1 SSA Of, S 1 J� 7SO q/tiyc�,q,, � S) �pL 440 . O�OG� o / 2s� /r' // rr/ Al h . vcv 1" - 30' GRAPHIC SCALE / P�y�pFggR/°st r -p4o j 0 15 30 oFe c 'Y �s 0, fhb 1 // QQt� utt n •:... PC 4.6 �y J °•00 �OJ, ON LOT CALCULATIONS 9C'pC0 v F ro \ LOT = 7,134 SQ. FT. rAG;y� °�Z \ LIVING AREA = 1.672 SQ. FT. py \ GARAGE . = 432 SQ. FT. �'`9�sp.�/( , �i° ENTRY = 38 SQ. FT. "PO'/c ST sus)•S92 1 LANAI = 96 S0. FT. 90�hTO'Q�� cs PATIO = 0 SQ. FT. y T P DRIVEWAY = 427 SQ. FT. 9} Y`? RP A/C PAD = 12 SQ. FT. N R/p \ � WALKWAY = 28 SQ. FT. }� IMPERVIOUS = 38% = 2705 SQ. FT. SOD = 4,429 SQ. FT. OFF LOT NS PREPARED FOR: RIGHT OF WAY�T1048D SQ. FT. DRIVE APRON = 42 SQ. FT. [�&11--HOMIN' PUBLIC S/W = 331 SQ. FT. l9�ftiub'S DL{�{�f3f SOD = 107 SO. FT. TOTALS AREA = 469 SQ. FT. BUILDING SETBACKS DRIVEWAY = 69 SQ. FT. FRONT: 22' SIDEWALK = 359 SQ. FT. REAR: 15' SOD = 4,536 SQ. FT. SIDE: 7.5' SIDE STREET: 20' LEGEND: NOTES: — ' — ' — BUILDING SETBACK LINE PI POINT OF INTERSECTION - PC POINT OF CURVATURE 1. ELEVATIONS SHOWN ARE PER LOT GRADING — — — CENTERLINE PT PONT OF TANGENCY PLANS PROVIDED BY THE CLIENT. — — RIGHT OF WAY LINE RP RADIUS POINT 2. ELEVATIONS ARE BASED ON NAVD 1988 XX PRC POINT OF REVERSE CURVATURE DATUM.- PROPOSED ELEVATION PCC POINT OF COMPOUND CURVATURE TYP TYPICAL PROPOSED DRAINAGE FLOW GS CONCRETE SLAB THIS PLOT PLAN IS INTENDED FOR PERMITTING PURPOSES (P) PER PLAT ONLY. THIS IS NOT INTENDED FOR THE CONSTRUCTION OF 0 CONCRETE (�) CALCULATED A/C AIR CONDITIONER PB PLAT BOOK THE PROPOSED HOUSE. REFER TO HOUSE PLAN AND PGs PAGES OPTION LIST FOR CONSTRUCTION. ALL BUILDING SET BACK S/W SIDEWALK SQ. FT. SQUARE FEET LINES SHOWN HEREON IS PER DATA FURNISHED BY CLIENT F.E.M.A. FEDERAL EMERGENCY MANAGEMENT AGENCY AND IS FOR INFORMATIONAL PURPOSES ONLY. F.I.R.M. FLOOD INSURANCE RATE MAP NAVD NORTH AMERICAN VERTICAL DATUM THIS IS NOT A SURVEY �&UE DRAINAGE&U NATIONAL GEODETIC VERTICAL DATUM EASEMENT PRIVATE THIS IS A PLOT PLAN ONLY UEE UTILITY EASEM NTE(PUBLIC)EASEMENT ��®®®N@TgI SURVEYOR NOTES: I HAVE EXAMINED THE F.I.R.M. MAP NO. 12101CO288F, 1. THE SURVEYOR HAS NOT ABSTRACTED THE DATED SEPTEMBER 26, 2014, AND FOUND THE SUBJECT PROPERTY LAND SHOWN HEREON FOR EASEMENTS, RIGHT APPEARS TO UE IN ZONE-X-. AREAS DETERMINED TO BE OUTSIDE THE OF WAY, RESTRICTIONS OF RECORD WHICH 0.2%ANNUAL CHANCE FLOODPLAIN. THE SURVEYOR MAKES NO MAY AFFECT THE TITLE OR USE OF THE LAND. GUARANTEES AS TO THE ABOVE INFORMATION. PLEASE CONTACT THE LOCAL F.E.M.A. AGENT FOR VERIFICATION. 2. NO UNDERGROUND IMPROVEMENTS HAVE BEEN LOCATED EXCEPT AS SHOWN. BEARING BASIS: BEARINGS SHOWN HEREON ARE BASED ON THE CENTERUNE OF WAGON A5hA 3. NOT VALID WITHOUT THE AUTHENTIC TRAIL STREET BEING N5335'22'W PER PLAT. ELECTRONIC SIGNATURE AND THE AUTHENTIC ELECTRONIC SEAL OF A FLORIDA LICENSED REVISED: A M E FR I CAN SURVEYOR AND MAPPER. (FIELD DATE:) S U FZ V IE Y I N G SCALE: 1�= 30 FEET �"•2�;e aq;rniy:,gnee nywreswmieman 8e M A P P I N G INC. %` f, DN:m=I mes W Btl mm mam ri an APPROVED BY: JB • gas suneyingaMapplig,ou, CERTIFICATION OF AUTHORIZATION NUMBER LB#6393 sr•= x "lic-Zbv1e n����°�^•=us 3191 MAGUIRE BOULEVARD, SUITE 200 �•• wic:�ovaiaeov;za;asrov FOR JOB NO. 171 D73 LOT 16, BLK 6 ORLANDO. FLORIDA 32803 `�v C*'"°�• THE � •:,r.:• FIRM (407) 426-7979 DRAWN BY: DSB PLOT PLAN 11 10 17 KJW WWW.AMERICANSURVEYINGANDMAPPING.COM JAMES W. BOLEMAN PSM# 6485 DATE 05-26'2{-O080-OO600'Ol60|Pasco County Property Appraiser Page lufl Data Current as Of: Weekly Archive - Wednesday, May 16, 2018 Parcel ID 05-26-21-0080-00600-0160 (Card: 001 of 001) Classification 00 - Vacant Residential Mailing Address 'Propert*Value 12602 TELECOM DR Land $2,684 Physical Address Extra Features $0 6512 WAGON TRAIL STREET Legal Description (First 4 Lines) Assessed (Non-School Amendment 1) $2,684 SILVERADO RANCH SUBDIVISION BLOCK 6 LOT 16 Jurisdiction City of Zephyrhills Land Detail (Card: 001 of 001) Line Use Units jype jCondition Value Additional Land Information I i 7 Code r Building Information - Use 00 - Unimproved (Card: 001 of 001) Unimproved Parcel 00 - Unimproved Extra Features (Card: 001 of 001) No Extra Features Sales History- See All 6 sales Previous Owner: DUNE FL LAND I SUB LLC Month/Year Book/Page IType Warranty Deed Vacant ulti-Parcel Sale ,Mineral Rights or Royalty Transfer 05 Vacant ]Multi-Parcel Sale , PASCO COUNTY, FLORIDA Permit No. - 1?7,1( , Date Permitted J-0-(0 Builder Name/Owner Name t —de Control County Parcel No. Sikwr� Address/Location Classification/Type of Use TRANSPORTATION IMPACT FEE Rate: Sq.FtUnit: 2, 236 Exempt E]Yes No How Determined Impact Fee Amount 3,, Zone No, TAZ: SCHOOL IMPACT FEE Account (056) Single-Family Detached House Amount $ (057) Mobile Home (058) Other Residential (123) Collection Fee Exempt F]Yes n No How Determined PARKS AND RECREATION FEE Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation Total Zone TOTAL AMOUNT $ 769. to Exempt []Yes No How Determined LIBRARY FEE Land Account Land Credit Land Total Facility Account Facility Credit Facility Total Exempt n Yes No How Determined Total Amounf�� RESOURCE FEE ERU TOTAL AMOUNT Prepared By Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE,OF PASCO COUNTY Acknowledgement below does not Imply acceptance of concurrence,but simply receipt of a copy of this form,placing the building permit owner on notice of this assessment and t1v conditions of payment for same. DATE RECEIVED BY RECEIPT NO. DATE BY PASCO A COUNTY DEVELOPMENT SERVICES Jl-10 %--d 8731 Citizens Drive Date.8/15/2018 COUNTY FLORIDA New Port'Richey,-FL 34654 Oi 014 SIAM. MAU& 727-847-2411` NOT A PERMF Receipt#: 1784890 FEE DESCRIPTION ACCOUNT CODE UNITS INVOICE# FEE AMOUNT PAID RECEIPT# DATE Impact Fee Residential Solid 24503100-329010 23.96 1374741 $23.96 $23.96 1784890 8/15/18 Waste Single Family TOTALS: $23.96 $23.96 Receipt# Paid By Check# CC Auth# Cashier ID Workstation Receipt Date Amt Paid 1784890 Check 791248 540 BCCCP06W 08/15/2018 $23.96 Total Payments: $23.96, Pavor Address Phone b R Horton 1341 Horton Circle Arlington TX 76011 Comments Solid we r City of Z phyrhills [ql Addres .6512 Wagon Trail S Parcel: 5 26 210080 0 0 0160 While you will be paying'your bill with Pasco County Development Services,the full amount of the credit card or e-check fees,NOT shown above,Is collected by First 01111ng payment services. MyReports/reports//PASCOPROD/PASCO/ReceiptPOS_V6.rpt 8/15/2018 Page 1 of 1 D.R. Horton-6512 Wagon Trail St-2,238 sq ft Column Es SQ. FEET PRICE MAIN OR LIVING: 2,2381 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 252,110.70 FEE SHEET $ 947.00 ADDRESS $ 40.00 DRIVEWAYJ $ 40.00 BUILDING: $ 1,045.94 ELECTRICAL: $ 213.08 PLUMBING: $ 142.05 MECHANICAL: $ 99.44 SUB-TOTAL $ 1,500.50 TOTAL $ 1,500.50 SEWER: n/a WATER: n/a IRRIGATION: $ - TOTAL: $ - WATER METER: n/a IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 2,053.85 PARK IMPACT FEES $ 769.56 SIF'S: $ 4,828.00 100.0% $ 4,828.00 1.0% $ 48.28 TOTAL: $ 4,876.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 11,331.69 DR Horton-6512 Wagon Trail St-2,238 sq ft- Column ts SQ. FEET + PRICE MAIN OR LIVING: 2,238 $ 112.65 OTHER AREA UNDER ROOF: - $ - OTHER: - $ - VALUATION $ 252,110.70 FEE SHEET $ 947.00 ADDRESS $ 40.00 DRIVEWAY $ 40.00 BUILDING: $ 1,045.94 ELECTRICAL: $ 213.08 PLUMBING: $ 142.05 MECHANICAL: $ 99.44 SUB-TOTAL $ 1,500.50 TOTAL $ 1,500.50 SEWER: WATER: IRRIGATION: $ - TOTAL: $ - N/A WATER METER: N/A IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: $ - INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL. $ 2,053.85 PARK IMPACT FEES $ 769.56 SIF'S: $ 4,828.00 100.0% $ 4,828.00 1.0% $ 48.2.8 TOTAL: $ 4,876.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 11,331.69 v City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: Date Received: Site: 6n, 5ZZ d I V l Permit Type: 2 Z 3 Approved w/no comments:❑ Approved w/the below comments. Denied w/the below comments: ❑ This comment sheet shall be kept with the permit and/or plans. Kalvin Switze�rans Examiner Date Contractor and/or Homeowner (Required when comments are present) Single Family Dwellin g Plan Review.Coinmerits l: F.F.E. shall'be,a minimum' .of 8" above,the road.elevation_and an engineered.site plan. '2.. :Lots shall-be graded.to comply,with R401.3 of the F.B:.C. .: , 3.: :Compaetionaest required_if 24" or more of fill dirt is brought in at any one place. . 4.::Tie in'.survey required before pouring concrete., 5_ Driveways:require a R.O.W. use permit: All.4:sides'of.driveway thru the sidewalk shall-have. : expansion matenal : :. 6. All setbacks ahall be met., .7. :Al-propertymarkers shall be uncovered and marked at time of first inspection: .8: :All A.D.A. requirements.shall be met.: . - 9.. No:electric;plumbing,.mechanical;,or framing shall be covered without an.inspection and approval-first.,. . 10.-All Garages shall,comply with section R302:6 of the F.B.C:(Fire Separation).. 11:Appliances shall not:be installed in a location where subject-to-mechanical darriage unless. :protected by approved barriers. M303.4 of the F.B.C. 12. Water heaters shall comply.with section.P607,3 of the F.B.C. 13. Foundation supports for A/C.units shall be raised at Least 31.1 above finished grade. M1308.1 14. Return air in all_bedrooms. F.B.C. .M1620.4 . . 15. Smoke detectors are to be:installed:in accordance:with R313.1 of the.F.B.C. 16: All glazing requirements are to be in accordance with R308.4,of the F.B:C. - 17. All means of egress are to be in accordance with-R311::of the F.B.C., 18. `.`Green gypsum board" shall not be used:as a backer_iri:showers or tubs. R702:4:2.F.B.C. 19. Combination-type AFCI breakers are.reguired.at all,locations requiring-an AFCI,type breaker: 20. Carboni monoxide.alarms will.be required in.new:construction that uses fossil-burning heating :or appliances of an attached garage: They shall be,installed in accordance with the F.B.C: 21. All plumbing,mechanical,:and:electrical shall be separate from unit to:unit: This-includes all. . underground:plumbing and electric: 22, All 2011 N:E:C: Codes will be enforced: . 23:Tamper= Resistant Receptacles in accordance with 406.11 of the 2011 N:E:C .24.:In accordance.with the Land Development:Code;lots.shall be. sodded before final of least 10, , feet'around the structure: 25.A.copy of the enerpp cacls shall be with permit at all'Hines. 26-Copy of fnal insulation f eport sliall b?-Provided with.petniit before.ftnab T.F.E.-Finished Floor Elevation F:B.C=Florida Building.Code 6th Edition R.O.W.-Right of Way A.D,A.-Americans with Disabilities Act N.E.C:-National Electric:Code(2011). . s FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Aria 1672 Elev C Builder Name: DRH Express Home �. /� Street: �j� Z l,{l�(, S Permit Office: 1.[{�i �1 City,State,Zip: Zephyrhills, F l ``[a (,� Permit Number: Owner: _ �J I �`Y Jurisdiction: &It( 00 Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1658.2 sgft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul, Exterior R=4.1 1372.20 ft2 b.Frame-Wood,Adjacent R=11.0 286.00 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 3 d.N/A R= ft2 10.Ceiling Types (1672.0 sgft.) Insulation Area 5. Is this a worst case? No a.Under Attic(Vented) R=30.0 1672.00 ft2 6. Conditioned floor area above grade(ft2) 1672 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(197.5 sgft.) Description Area a.Sup:Attic, Ret:Main,AH:Main 6 334 a. U-Factor: Dbl,U=0.34 157.50 ft2 SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.55 40.00 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.34 a.Central Unit 28.6 SEER:14.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 28.6 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 4.411 ft. Area Weighted Average SHGC: 0.316 14.Hot water systems 8. Floor Types (1672.0 sgft.) Insulation Area a.Electric Cap:50 gallons EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1672.00 ft2 b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat n AH�� Glass/Floor Area: 0.118 Total Proposed Modified Loads: 57.60 r Total Baseline Loads: 57.69 I hereby certify that the plans and specifications covered.by Review of the plans and a�ZHES7,q�� this calculation are in compliance with the Florida Energy specifications covered by this a �. 0 Code. calculation indicates compliance �w � with the Florida Energy Code. t~ rrrr: ';", cu,;�4,C0 PREPARED BY: L►11c Before construction is completed _ DATE: 11-9-17 this buildingwill be ins ected for p C7 t€i; compliance with Section 553.908 * °. I hereby certify that this building,as designed,is in compliance Florida Statutes. with the Florida Energy Code. BCD4 OWNER/AGENT: v��. ', � BUILDING OFF CIAL: DATE: //'� /? DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. - 11/9/2017 10:27 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Ada 1.672 Elev C Builder Name: DRH Express Homes 612SI L LA Street: 1� Permit Office: ,� S F City,State,Zip: Zephyrhills, q1 Permit Number: Owner: - M6 ,\g Jurisdiction: Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) I. New construction or existing New(From Plans) 9. Wall Types(1658.2 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul, Exterior R=4.1 1372.20 ft2 b.Frame-Wood,Adjacent R=1 1.0 286.00 ft2 3. Number of units,if multiple family I c.N/A R= ft2 4. 'Number of Bedrooms 3 d.N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types (1672.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1672.00 ft2 6. Conditioned floor area above grade(W) .1672 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2, 7. Windows(I 97.5 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 334 a. U-Factor: DIJI,U=0.34 157.50 ft2 SHGC: SHGC=0.31 b. U-Factor: DIJI,U=0.55 40.00 ft2 12.Cooling systems kBtu/hr Efficiency SHGC; SHGC=0.34 a.Central Unit 28.6 SEER:14.00 c. U-Factor: N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a..Electric Heat Pump 28.6 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 4.411 ft. Area Weighted Averaqe SHGC: 0.316 14.Hot water systems Average 8, Floor Types (1672.0 sqft.) Insulation Area a.Electric Cap:50 gallons a.Slab-On-Grade Edge Insulation R=0.0 1672.00 ft2 b. Conservation features EF:0.950 b.N/A R= ft2 . None c.NIA R= ft2 15,Credits Pstat Glass/Floor Area: 0.118 T.otal Proposed Modified Loads: -57.60 PASS Total Baseline Loads: 57.69 I hereby certify that the plans and specifications covered by Review of the plans and 1,0113A specifications covered by this S71 this calculation are in compliance with the Florida Energy 0 Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: L Before construction is completed 6 DATE: 11-01-17 this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. OWNER/AGENT: BUILDING OFFICIAL' DATE: DATE: Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certifl6d,tact6ry-sealed in accordance' with R403.2.2.1. Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. 11/9/2017 10:27 AM EnergyGauge@ USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 4 FORM R405-2014 PROJECT , Title: Aria 1672 Elev C Bedrooms: 3 Address Type: Lot Information Building Type: User Conditioned Area: 1672 Lot# 16/6 Owner: Total Stories: 1 Block/SubDivision: Silverado Ranch #of Units: 1 Worst Case: No PlatBook: Builder Name: DRH Express Homes Rotate Angle: 225, Street: Permit Office: Cross Ventilation: County: Pasco Jurisdiction: Whole House Fan: City,State,Zip: Zephyrhills, Family Type: Single-family FL, New/Existing: New(From Plans) Comment: Garage R Face SW CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Tampa FL_TAMPA_INTERNATI 2 39 91 70 75 645.5 54 Medium BLOCKS Number Name Area Volume 1 Blocki 1672 14496.2 SPACES Number Name Area Volume - Kitchen Occupants. Bedrooms Infil iD Finished Cooled Heated 1 Main 1672 14496.2 Yes 4 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio Main 192.68 ft 0 1672 ftz ---- 0.5 0 0.5 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck - Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1870 ftz 0 ftz Dark 0.92 No 0.9 No 0 26.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 1672 ftz Y N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1. Under Attic(Vented) Main 30 Blown 1672 ftz 0.11 Wood 11/9/2017 10:27 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 4 FORM R405-2014 WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 N=>SW Exterior Concrete Block-Int Insul Main 4.0999 18 0 8 8 156.0 ft2 0 0.6 0 2 W=>SE Exterior Concrete Black-Int Insul Main 4.0999 44 .0 8 8 381.3 ftz 0 0.6 0 3 S=>NE Exterior Concrete Block-Int Insul Main 4.0999 38 8 8 8 335.1 ft2 0 0.6 0 4 E=>NW Exterior Concrete Block-Int Insul Main 4.0999 57 8 8 8 499.8 ft2 0 0.6 0 5 N=>SW Garage Frame-Wood Main 11 20 0 8 8 173.3 ft2 0.23 0.01 0 6 W=>SE Garage Frame-Wood Main 11 13 0 8 8 112.7 ft2 0 0.23 0.01 0 DOORS # Ornt Door Type Space Storms U-Value - Width Height Area Ft In Ft In 1 N=>SW Insulated Main None .4 3 6 8 20 ft2 2 N=>SW Wood Main None .46 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered orientation => changed to As Built rotated 225 degrees). / Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N=>SW 1 Vinyl Low-E Double Yes 0.34 0.31 - 31.0 ft2 1 ft 0 in 3 ft 3 in Drapes/blinds Exterior 5 2 N=>SW 1 Vinyl Low-E Double Yes 0.34 0.31 15.5 ft2 1 ft 0 in 4 ft 9 in Drapes/blinds Exterior 5 3 N=>SW 1 Vinyl Low-E Double Yes 0.34 0.31 2.5 ft2 7 ft 8 in 0 ft 2 in Drapes/blinds Exterior 5 4 S=>NE 3 Vinyl Low-E Double Yes 0.34 0.31 62.0 ft2 1 ft 0 in 0 ft 9 in Drapes/blinds Exterior 5 5 S=>NE 3 Vinyl Low-E Double Yes 0.34 0.31 31.0 ft2 8 ft 0 in Oft 1 in Drapes/blinds Exterior 5 6 E=>NW 4 Metal Low-E Double Yes 0.55 0.34 40.0 ft2 12 ft 0 in 0 ft 8 in Drapes/blinds Exterior 5 7 E=>NW 4 Vinyl Low-E Double Yes 0.34 0.31 15.5 ft2 1 ft 0 in 0 ft 9 in Drapes/blinds Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 432.177 ft2 432.177 ft2 49 ft 8.67 ft 0 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000386 1691.2 92.85 174.61 .2892 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump None HSPF:8.2 28.6 kBtu/hr 1 sys#1 1 119/201 7 1 0:27 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 4 FORM R405-2014 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Norie SEER:14 28.6 kBtu/hr 858 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 50 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ftz DUCTS / ----Supply---- ----Return---- Air CFM 25 CFM25 HVAC# # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 334 ftz Main 40 ftz Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Cool' Jan Feb Mar Apr May Jun Jul Auge Oct Nov Dec Heatin f Jan l Feb Mar E Apr. f May 4 Jun 4 Jul 4 Auf Sep f Oct Nov Dec Venting [ ]Jan [ l Feb Mar [X]Apr [ May l Jun [ Jul [ Aug [ Se [ Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 . 68 66 66 1 1/9/201 7 1 0:27 AM EnergyGauge@ USA-FlaRes2014 Section R405.4.1 Compliant Software' Page 4 of 4 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerformance Index,the more efficient the home. Zephyrhills, FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul, Exterior R=4.1 1372.20 ft2 b.Frame-Wood,Adjacent R=11.0 286.00 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 3 d.N/A R= ft2 10.Ceiling Types Insulation Area 5. Is this a worst case? No a.Under Attic(Vented) R=30.0 1672.00 ft2 6. Conditioned floor area(ft2) 1672 b.N/A R= ft2 7. Windows** Description Area c.N/A R= ft2 11. Ducts R ft2 a. U-Factor: Dbl, U=0.34 157.50 ft2.SHGC: SHGC=0.31 a.Sup:Attic,Ret:Main,AH:Main 6 334 b. U-Factor: Dbl, U=0.55 40.00 ft2 SHGC: SHGC=0.34 -12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a.Central Unit 28.6 SEER:14.00 SHGC: d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 28.6 HSPF:8.20 Area Weighted Average Overhang Depth: 4.411 ft. Area Weighted Average SHGC: 0.316 8. Floor Types Insulation Area 14.Hot water systems a.Electric Cap:50 gallons a.Slab-On-Grade Edge Insulation R=0.0 1672.00 ft2EF:0.95 b.N/A R= ft2 b. Conservation features c.N/A R= ft2 None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for BuildingT3E S Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Date: Ile-III Address of New Home: City/FL Zip: WE shy/ *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida-Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 1 1/9/201 7 1 0:27 AM EnergyGaugeg USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 Florida Department of Business and Professional Regulations Residential Whole Buildin Performance and Prescriptive Methods ADDRESS: Permit Number: Zephyrhills,FL, MANDATORY REQUIREMENTS See individual code sections for full details. 401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law [Section 553.9085,Florida Statues]requires the EPL display card to be included as an addendum to each sales contract for both presold and r onpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a"dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found.in Appendix C. R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.1 through R402.4.4. O R402.4.1-Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.The sealing methods between dissimilar materials shall allow for differential expansion and contraction. • R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table 402.4.1.1,as applicable to the method of construction. Where required by the code official,an approved third party shall inspect all components and verify compliance. • R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2,and 3 air changes per hour in Climate Zones 3 through 8..Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1. Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3.Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. O R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers and outdoor combustion air. O R402.4.3 Fenestration air leakage.Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400 or AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. O R402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm(0.944"Us)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential.All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls that,except during defrost,prevent supplemental heat.operation when the heat pump compressor can meet the heating load. R403.2.2 Sealing(Mandatory)AII ducts,air handlers,and filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post-construction or rough-in testing below. Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either an energy rater certified in accordance with Section 553.99,Florida Statutes,or as authorized by Florida Statutes,to be"substantially leak free"by either of the following: 1. Post-construction test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g. (25 Pa)across the entire system,including the manufacturer's air handler enclosure.All register boots shall be taped or otherwise sealed during the test. 2. Rough-in test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25Pa)across the system,including the manufacturer's air handler enclosure.All registers shall be taped or otherwise sealed during the test.If the air handler is not installed at the time of the test,total leakage shall be less than or equal to 3 cfm (85 Umin)per 100 square feet(9.29 m2)of conditioned floor area. Exceptions: 1. The total leakage test is not required for ducts and air handlers located entirely within the building envelope. 2. Duct testing is not mandatory for buildings complying by Section R405 of this code. 11/9/2017 10:27 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Com Page 1 of 3 ` FORMH4O5-2014 MANDATORY REQUUREMENTS ~ (Continued) . . — O �03�.3 Building Cavities(Mandatory). Building framing cavities shall not baused as ducts mplenums. O n403.3 Mechanical system piping insulation(Mbnuaton). Mechanical system piping capable of carrying fluids above 1oo1`(4U1C) u,below ss"F(1u"C)shall bo insulated ma minimum ofBo, R403.3.1 Protection m piping Insulation. ' O n403.4'1 Circulating hot water systems(Manuomry). Circulating hot water systems shall bo provided with an automatic mreadily accessible manual switch that can turn off the hot-water circulating pump when the systemis not inuse. O n403.4.3Hmo traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical piperlsers shall have heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a downward and upward bend ofm least o}ymooeo(8mmn)mmeomomterdiomuununoneamuov/uvmaterona/ovatodaumuneompoosm/n m the storage tank. u n403.4'4 Water heater efficiencies(Mondatny). O m«uu.«.4.1 Storage water heater temperature controls _ . R40o.o.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls capable of adjustment hom the bm v� u,tbehiohwntuoon�ab��mpen� m �0 uonQn�x�nim mi nimum tempoouuneoeuingnangeshall bn from 1uO~Fx,14n^F(3o~Cmoo,C). . ;��1.2 Shutdown' A separate switch ma clearly marked circuit breaker shall be provided to permit the power supplied m electric service systems to bo turned off,A separate valve shall be provided topermit the energy supplied m the main bumor(u) of combustion types vf service water heating systems tobo turned off. O Rvuo.o�2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation,Commercial Provisions,for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water heating category. Solar water heaters shall met the criteria Section R+nu.4.4.u.1. . R403.4.4.2.1 Solar water heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system.The solar.energy factor of a system shall be determined from the Florida Solar Energy Center Directory nf Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors, and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol,Collectors in installed solar water heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 4o degrees of the horizontal;and _ u. Be installed ozom orientation within 4a degrees m[true south. O provided ventilation that meets the requirements nfthe Florida Building Code,Residential— Florida Building Code,Mechanical,_applicable,—with other_ approved means o ventilation. outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. Roune**�tinguoduno/iogequipmon�V0ondomn0 Thandkmingse��nnanmandom�fn,ouuonganuhoahnQoquipmen� O ' ' O g403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units'(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section RaOu.1.This code does not allow designer safety factors,provisions for future expansion m other factors which affect equi m ntaizing.8ystemoizingoa|cU|oUonushal(nm|nu|uue|padoumauedby|ooa|intnnniuentmeohanioalventilatiun such aystandard kitchen and bathroom exhaust systems. ' ^ R403.6'1.1 Cooling equipment umpacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total| ad but not more than 1 15 times greaterthan the total load calculated according mthe procedureselected in Section uoo.V.or the closest available i manufacturer's product lines.The corresponding latent capacity ofthe equipment shall not bo less than the calculated latent load. . ` 11/9/20710:27AM EnnrgyGougeg USA'RaReo2o4 -SanUonR4o*�.1 Com Page uof3 FORM R405-2014 MANDATORY REQUIREMENTS ® (Continued) O R403.6.1.1 Cooling equipment capacity.(continued) . The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacture's expanded performance data.shall be used to select cooling-only equipment.This selection shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower cfm provided by the expanded performance data, the design value for entering wet bulb temperature and the design value for entering dry bulb temperature. Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space. Exceptions: 1. Attached single-and multi-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida-registered engineer,in attached single-and multi-family units,the capacity of equipment may be sized in accordance with good design practice. O R403.6.1.2 Heating equipment capacity • R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section R403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load. • R403.6.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.6.1.. • R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.6.1. O R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. ❑ R403.7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the Commercial Provisions in lieu of Section R403. ❑ R403.8 Snow melt system controls(Mandatory). Snow and ice-melting systems,supplied through energy service to the building,shall include automatic controls capable of shutting off the system when the pavement temperature is above 55°F,and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F. ❑ R403.9 Swimming pools,inground spas and portable spas(Mandatory). The energy requirements for residential pools and inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSI/APSP-15.The energy requirements for portable spas shall be in accordance with ANSI/APSP-14. O R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on-off switch that is mounted outside the heater to allow shutting off the heater without adjusting the thermostat setting. • R403.9.1.1 Gas and oil-fired pool and spa heaters. All gas-and oil-fired pool and space heaters shall have a minimum thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013 when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights. • R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are riot required to meet this standard. O R403.9.2 Time switches. Time switches or other control method that can automatically turn off and on heaters and pumps according to a preset schedule.shall be installed on all heaters and pumps.Heaters,pumps and motors that have built in timers shall be deemed in compliance with this equipment. Exceptions: 1. Where public health standards require 24-hour pump operations. 2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation. O 'R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Outdoor pools deriving over 70 percent of the energy for heating from site-recovered energy,such as a heat pump or solar energy source computed over an operating season. ❑ RR404.1 Lighting equipment(Mandatory). A minimum of 75 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps.. Exception: Low-voltage lighting shall not be required to utilize high-efficacy lamps. O R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights ❑ R405.2 Performance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R-6. O' R405.2.1 Performance ONLY. Ceilings shall have minimum insulation of R-19.Where single assemby of the exposed deck and beam type or concrete deck roofs do not have sufficent space, R-10 is allowed. 11/9/2017 10:27 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Com Page 3 of 3 FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Aria 1672 Elev C Builder Name: DRH Express Homes Street: Permit Office: City,State,Zip: Zephyrhills, FL, Permit Number: Owner: Jurisdiction: Design Location: FL,Tampa COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and d doors The space between window/door jambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation,insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations,and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated,and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 11/9/2017 10:27 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Envelope Leakage Test Report Prescriptive and Performance Method Project Name: Aria 1672 Elev C Builder Name; DRH Express Homes Street: Permit Office: City,State,Zip: Zephyrhills, FL, Permit Number: Design Location: FL,Tampa. Jurisdiction: Cond.Floor Area:: 1672 sq.ft. Cond.Volume: 14496 cu ft. Envelope Leakage Test Results Leakage Characteristics Regression Data: C: - n: R: Single or Multi Point Test Data CFM(50): HOUSE PRESSURE FLOW: ELA' 1 Pa cfm EgLA: 2 Pa cfm ACH: 3 Pa cfm ACH(50): 4 Pa cfm 5 SLA: Pa cfm 6 Pa cfm R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2,3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall.be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1. Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3.Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems, if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. .I hereby certify that the above envelope leakage Where required by the code official, 0 'tV1 performance results demonstrate compliance testing shall be conducted by an `•' with Florida Energy Code requirements in approved third party. A written accordance with Section R402.4.1.2. report of the results of the test shall be signed by the third party i,;;al - t7 conducting the test and provided to SIGNATURE: the code official. PRINTED NAME: WE DATE: BUILDING OFFICIAL: DATE: 1 1/9/201 7 1 0:27 AM EnergyGauge@ USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 Manual SCompliance Report Job: + wrightsoft Date: Oct 10,2014 Entire House By: Progressive Air Systems, Inc. 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-8.47-3898 Fax:727-815-3399 License:CAC033669 t % di6ct Information— J For: DR Horton/ Express Homes Lot 16 Blk 6 Silverado, Zephyrhills,,FL. ling Equi• t"P MP ,V Design Conditions Outdoor design DB: 91.2°F Sensible gain: 21334 Btuh Entering coil DB: 76.1 OF Outdoor design WB: 77.1 OF Latent gain: 2877 Btuh Entering coil WB: 63.0°F Indoor design DB: 75.0°F Total gain: 24211 Btuh Indoor RH: -50% Estimated airflow: 1000 cfm Manufacturer's Performance Data at Actual Design Conditions Equipmenttype: SplitASHP Manufacturer: Carrier Model: CH14NB030***'A+FB4CNP030 Actual airflow: 1000 cfm Sensible capacity: 23532_ Btuh 110%of load Latent capacity: 3786 Btuh 132%of load Total capacity: 27318 Btuh 113%of load SHR: 86% Design Conditions Outdoor design DB: 40.0°F Heat lost: 20312 Btuh Entering coil DB: 69.6°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: SpIltASHP Manufacturer: Carrier Model: CH14NB030****A+FB4CNP030 Actual alrfiow: 1000 cfm Output capacity: 25625 Btuh 126%of load Capacity balance: 31 OF Supplemental heat required: 0 Btuh Economic balance: -99 OF Backup equipment type: Eiec strip Manufacturer: Model: Actual airflow: 1000 cfm Output capacity: 6.4 kW 1080%of load. Temp. rise: 20 OF Meets are all requirements of ACCA Manual S. Wrightsoft- Right-SuiteQ Universal 2017 17.0.21 RSU25554 2017-Nov-'09 10:29:06 Page I ...onXWdghtsoft Files\Express horneskAria,4EA8.rup Calc=MJ8 House faces:SW Load Short Form Job: - - wc-ightsoft° Date: Oct 10,2014 Entire House By: Progressive Air Systems, Inc 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 For: DR Horton/Express Homes Lot 16 Blk 6 Silverado, Zephyrhills, FL � ' • • ma • Htg Clg Infiltration Outside db(OF)- 40 91 Method Simplified Inside db(OF)_ 70 75 Construction quality Semi-tight Design TD (OF) 30 16 Fireplaces 0 Daily range - L Inside humidity (%) 50 50 Moisture difference(gr/lb) 26 54 HEATING EQUIPMENT COOLING EQUIPMENT Make Carrier Make Carrier Trade CARRIER Trade CARRIER Model CH14NB030****A Cond CH14NB030****A AHRI ref Coil FB4CNP030 AHRI ref Efficiency 8 HSPF Efficiency 11.5 EER, 14 SEER Heating input Sensible cooling 22500 Btuh Heating output 29600 Btuh @ 47OF Latent cooling 7500 Btuh Temperature rise 27 OF Total cooling 30000 Btuh Actual air flow 1000 cfm Actual air flow 1000 cfm Air flow factor 0.049 cfm/Btuh Air flow factor 0.047 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.88 Capacity balance point=31 OF Backup: Input=6 kW Output=21934 Btuh, 100 AFUE ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) M bed 237 3345 3280 165 154 dining 202- 2812 3947 138 185 greatroom 257 3318 4133 163 194 M wic 49- 744 338 37 16 we 25 372 169 18 8 M bath 135 1579 .845 78 40 . kitchen 146 170 1547 8 73 laundry 42 252 843 12 40 A/C closet 14 16 25 1 1 bed3 - 154 1615 1675 80 79 foyer 162 1679 1494 83 70 bath2 60 659 322 32 15 bed2 166 3751 2716 185 127_ Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. J. wri htsoft° 2017-Nov-0910:29:06 ,..�� 9 Right-Suite®Universal 2017 17.0.21 RSU25554 ACC% ...on%Wrightsoff FIIes%Express homes\Ada 4EAB.rup Cale=MA House faces:SW Page 1 -Entire douse d 1647 20312 21334 1000 1000 Other equip loads 0 0 Equip. Qa 1.00 RSM 21334 Latent cooling 2877 TOTALS 1647 20312 24211 1000 1000 Calculations approved by ACCA to.meet all requirements of Manual J 8th Ed. wrightsofta Right-Suite®Universal 2017 17.0.21 RSU25554 2017-Nov-09 10:29:06 ACCA Page 2 ...on\Wrightsoft Files\F�cpress homes\Aria 4EA6.rup Calc=MJ8 House faces:SW Project Summary Job: - - wrightsoft" Entire House 9 Byte: Oct 10,2014 Progressive Air Systems, Inc 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 P'Tolec h • • For: DR Horton/Express Homes Lot 16 Blk 6 Silverado, Zephyrhills, FL Notes: Weather: Tampa Intl AP, FL, US Winter Design Conditions . Summer Design Conditions Outside db 40 OF Outside db ­91 -OF Inside db 70 OF Inside db 75 OF Design TD 30 OF Design TD 16 OF Daily range. 'L Relative humidity 50 % Moisture difference 54 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 16693 Btuh Structure 16219 Btuh Ducts 3619 Btuh Ducts 5114 Bfuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh e Humidification 0 Btuh Blower e) 0 Btuh Piping 0 Btuh Equipment load 20312 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 21334 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 2231 Btuh Ducts 646 Btuh Central vent (0 cfm) 0 Btuh Heating Coolingg (none) Area(ft2 1647 1647 Equipment latent load 2877 Btuh Volume(ft3) 14494 14494 Air changes/hour 0.26 0.14 Equipment total load 24211 Btuh Equiv.AVF (cfm) 63 34 Req. total capacity at 0.75 SHR 2.4 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER Trade CARRIER Model CH14NB030****A Cond CH14NB030****A AHRI ref Coil FB4CNP030. AHRI ref Efficiency 8 HSPF Efficiency 11.5 EER, 14 SEER Heating input Sensible cooling 22500 Btuh Heating output 29600 Btuh @ 470F Latent cooling 7500 Btuh Temperature rise 27 OF Total cooling 30000 Btuh Actual air flow 1000 cfm Actual air flow 1000 cfm Air flow factor 0.049 cfm/Btuh Air flow factor 0.047 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.88 Capacity balance point=31 OF Backup: Input=6 kW, Output=21934 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. ^.` wrightsoft' Right-Suite®Universal 2017 17.0.21 RSU25554 2017-Nov-09 10:29:06 ACC ...on\Wdghtsoft Files\Express homes\Aria 4EAB.rup Calc=MJ8 House faces:SW Page 1 FORM R405-2014 RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST Florida Department of Business and Professional Regulation Simulated Performance Alternative(Performance)Method Applications for compliance with the 2014 Florida Building Code, Energy Conservation via the residential Simulated Performance method shag include 0 This checklist 0 A Form R405 report that documents that the Proposed Design complies with Section R405.3 of the Florida Energy Code. This form shall include a summary page indicating home address, e-ratio and the pass or fail status along with summary areas and types of components, whether the home was simulated mulated as a worst-case orientation, name and version of the compliance software tool, name of individual completing the compliance report(1 page)and an input summary checklist that can be used for field verification(usually 4 pages/may.be greater). El Energy Performance Level(EPL)Display Card(one page) 0 Mandatory Requirements(three pages) Required prior to CO for the Performance Method. 0 Air Barrier and Insulation Inspection Component Criteria checklist(Table R402.4.1.1 - one page) 0 A completed Envelope Leakage Test Report(usually one page) 0 If Form R405 duct leakage type indicates anything other than "default leakage", then a completed Form R405 Duct Leakage Test Report(usually one page) 1 10:39:34 AM Energydaugee-USRCZB v5.1 Page 1 of 1 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Envelope Leakage Test Report Prescriptive and Performance Method Project Name: SILVERADO Builder Name: D R HORTON Street: 6512 Wagon Trail St Permit Office: City,State,Zip: Zephyrhills,FL 33541 Permit Number: Design Location: 6512 Wagon Trail St(Lot 16) Jurisdiction: Cond.Floor Area: 1828 Cond.Volume: 15849 Envelope Leakage Test Results Leakage Characteristics Regression Data: C: n: R: CFM(50): 1623 Single or Multi Point Test Data ELA: 89 HOUSE PRESSURE FLOW: EgLA: 211 I 1 50 Pa 1623 cfm ACH: 6.14 2 0 Pa 0 cfm SLA: .05 3 0 Pa 0 cfm 4 0 Pa 0 cfm ACH(50)*: 6.14 *For prescriptive projects,tested leakage must be<=7 5 0 Pa 0 cfm ACH(50). For performance projects, tested leakage must be<=the ACH(50)shown on Form R405-2014 6 Pa cfm for this project. R402.4.1.2 Testing.The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zones 1 and 2.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statutes or individuals licensed as set forth in Section 489.105(3)(f),(g),or(i)or an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration 3.Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. I hereby certify that the above envelope leakage performance results demonstrate compliance with Florida Energy Code requirements in accordance with Section R402.4.1.2. Testing shall be conducted by either individuals as defined in Section 553.993(5)or(7),Florida Statutes 0.1i TAT or individuals licensed as set forth in Section ~ 'p ( )() (g),or(i)or an approved third party.AIM4 yt'•.t,' <o written report of the results of the test shall be signed �~ Digitally signed by Michael by the third party conducting the test and provided to - (4llj• > Silberstein the code official. * a a Date:2018.09.19 14:51:26 EDT CN=Michael Silberstein,O=TopBuild I� Home Services,OU, EMAILADDRES S=Michael.S it b erstei Signature: n@lopbuild.com,C=US Printed Name: Michael Silberstein BUILDING OFFICIAL: G Date: 09/19/2018 DATE: Thank you for allowing TopBuild the opportunity to provide the above services for you.Please feel free to contact me with any questions. 10/25/2017 399056 5335 - 8TH STREET (813)780-0020 CERTIFICATE OF OCCUPANCY Address: 6512 WAGON TRAIL ST Owner: DR HORTON INC ZEPHYRHILLS, FL. 12602 TELECOM DR Subdiv: SILVERADO TAMPA FL 33637-0935 Parcel: 05-26-21-0080-00600-0160 Work Type: 101-NEW CONST/SFR Construction Type: NOT APPLICABLE ❑ Sprinklers Use Classification: NOT APPLICABLE Permit Number: 19711 Date: 9/24/2018 !7 a ISSUED E0. BUILDI OFFICIAL : WATER MUST BE CHANGED OVER WITHIN 10 DAYS OF ISSUANCE GARBAGE DEPOSIT MUST BE APPLIED FOR PRIOR TO ISSUANCE CITY OF " NOTICE BUILDING ZEPHYRNILLS DEPARTMENT OF ADDITION OR CORRECTION r • -NOT REMOVE ADDRESS DATE PERMIT f f/41-1 I---)( 13:7 1 ( I THIS JOB HAS NOT BEEN COM` LETED. The following additions or corrections shall be made before the job will be accepted. V0 A10 It is unlawful for any Carpenter,Contractor,Builder,or other persons,to AFTER CORRECTIONS ARE MADE CALL cover or cause to be covered,any part of the work with flooring,lath,earth 780-0020 FOR REIN CTION or other material,until the proper inspector has had ample time to approve the installation. OFFICE HOURS 7:30AM-4:30 PM MON.-FRI. INSPECTOR