Loading...
HomeMy WebLinkAbout18-19727 CITY OF ZEPHYRHILLS 5335-STH STREET (813)780-0020 19727 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL PERMIT INFORMATION LOCATION INFORMATION Permit#:19727 Issued: 5/29/2018 Address: 3076 KRESTERBROOKE LANE Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 225,863.25 Total Fees: 17,557.97 Subdivision: HIDDEN RIVER Amount Paid: 17,557.97 Date Paid: 5/29/2018 Parcel Number: Z,4-26-21-0100-00000-0730 CONTRACTOR.INFORMATION OWNER INFORMATION Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC Addr: 4600 W. CYPRESS ST STE 200 Address: 4600 W. CYPRESS ST STE 200 TAMPA, FL. 33607 TAMPA, FL 33607 Phone: (813)574-5743 Lic: Phone: 813-574-5700 Work Desc: CONSTRUCT SINGLE FAMILY 2,005 SQ FT APPLICATION FEES BUILDING FEE 1,268.40 ELECTRICAL FEE 263.25 MECHANICAL FEE 122.85 PLUMBING FEE 175.50 SEWER CONNECTION RESIDEW 2,090.00 WATER METER RES 3/4" 473.78 WATER CONNECTION RESIDENT 1,010.00 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE NEW 7,128.00 SCHOOL-SFR NEW 1% 71.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32 Inspections ki6quired FOOTER 2ND ROUGH PLUMB MISC INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,.Specifications and Must Accompany Application. All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONT TORS SIGNATURE PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER Lennar Homes-3076 Kresterbrooke Lane-2,005 Sqft Column ts SQ. FEET PRICE MAIN OR LIVING: 2,005 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 225,863.25 FEE SHEET $ 1,170.00 ADDRESS $ 40.00 DRIVEWAY $ 40.00 BUILDING: $ 1,273.40 ELECTRICAL: $ 263.25 PLUMBING: $ 175.50 MECHANICAL: $ 122.85 SUB-TOTAL $ 1,835.00 TOTAL $ 1,835.00 SEWER: $ 2,090.00 WATER: $ 1,010.00 IRRIGATION: $ - TOTAL: $ 3,100.00 WATER METER: $ 473.78 IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 5,962.13 PARK IMPACT FEES $ 769.56 SIF'S: $ 7,128.00 100.0% $ 7,128.00 1.0% $ 71.28 TOTAL: $ 7,199.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 17,562.97 24-26-21-0100-00000-0730 1 Pasco County Property Appraiser Page 1 of 1 i Data Current as Of: Weekly Archive - Saturday, May 12, 2018 Parcel ID 24-26-21-0100-00000-0730 (Card: 001 of 001) Classification 00 - Vacant Residential Mailing Address Property Value DUNE FL LAND I SUB LLC Ag Land $0 C/O HAWK MANAGEMENT CO LLC Land $29,040 2502 N ROCKY POINT DR STE 1050 Building $0 ROCKY POINT FL_33607-5995 Extra Features $0 Physical Address 3076 KRESTERBROOKE LANE ZEPHYRHILLS, FL 33540 3ust Value $29,040 Assessed (Non-School Amendment 1) $29,040 Legal Description (First 4 Lines) See Plat for this Taxable Value $29,040 Subdivision HIDDEN RIVER PHASE ONE B PB 76 PG 077 LOT 73 OR 8606 PG 3376 jurisdiction City of Zephyrhills Land Detail (Card: 001 of 001) Line Use Description`Zoning Units Type _ Price _ Condition +Value 1 — 0100 SFR MPUD116,000.00i SF $4.75 1.00 $28,500 2 _f 0100 SFR MPUD 1 600.00 SF $0.90 1.00 ( $540 _ Additional Land Information FEMA Acres IIIII` 0.15 ,Tax Area 30ZH Code Residential Code HDRVCPI I -�` ----- ---_ _. Building Information - Use 00 - Unimproved (Card: 001 of 001) Unimproved Parcel 00 - Unimproved Extra Features (Card: 001 of 001) Line _Description Year _ Units 'iValue No Extra Features Sales History- See All 5 sales Previous Owner: Month/Year Book/Page Type I OR Code Condition !Amount 09/2011 8606 / 3376 Warranty Deed 05 _ Vacant ! Multi-Parcel Sale 06/2010 8360 / 1872 Certificate of Title j_ 12 j Vacant j $0 12/2005 6748 / 0894 Warranty Deed i � Vacant $0 f http://search.pascopa.com/parcel.aspx?parcel=2126240100000000730 5/16/2018 . . M��Mimic 201808873310.0 - Q)5/29/2018 K. DPtV Clerk OMPTRO . o 1of ppUL OR 8K 9 73uL Permit No. Parcel ID No 24-26-21-0100-00000-0730 NOTICE OF COMMENCEMENT state of Florida County of Pasco THE UNDERSIGNED hereby gives notice that improvement wi|ibommJnmcertainma|pmpedy.andi0000undonoo*itxoxupter713.Fbr|doGtatumu. the following information io provided in this Notice vfCommencement: I Description ofProperty: uagm| ooee /durex : 3076 Kresterbrooke Lane Zephryhills FL 33541 Single i| Residence/Foo|/Go�enEndoaunn/Ranco u� oenom|o,scnnovnof|mpm"emom ''y ~''' n. Owner Information: LennarHomem LLO. Name 4600 W Cypress St. Ste 200 Tampa FL-336O7 Address city State Interest inProperty: Name of Fee Simple Titleholder: N/A (if other than owner) Address city State ' Contractor:-- Name Address city State Contractor's Telephone No.: 813.574.5700 a Surety: NIA Name Address city State Amount of Bond: Telephone No.: o. Lender: womo _ - --- umuorunxapxonewo.: . ` z Persons within the State of Florida designated by the owner upon whom notices mother documents maybe served as provided by Gectionn3.1c(l)(a)(7),FloridaStatutes: Name ^ 4600 W Cypress St, Ste 200 Tampa F Address city State Telephone Number of Designated m B13 uPo Person: .574.5700 ' o. m addition to himself,the owner designates vf____ to receive a copy of the Lienor's Notice as provided in Section 713.13(l)(b),Florida Statutes. Tp|ephvnb Number nf Person v,Entity Designated byOwner: n. Expiration date of Notice of Commencement is one year from the date of recording unless a different date|ospecified: WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE "'^-THE FIRST INSPECTION," WITH YOUR LENDER onxm ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. STATE orFLoRID� COUNTY opP|wsLL�� Signature of Owner or Owner's Authorized Officer/Director/Partner/Manager Vice President oignamryaTmmun/ne The foregoing instrument was acknowledged before methis 30_day of March Steve Robert Smith (type of authority, (name of party o a alf of rn instrument was executed). Personally Known R OR Produced Identification El Notary Signature-- Type of Identification Produced Name(Print) Elissai HMIPran Verification pursuant ho Section ou.au5.Florida Statutes. Under penalties uf perjury,|declare that|have read the foregoing and that the facts stated in K are true oo the best u«my knowledge and belief. EL19SAM.HOLLERAN Signature of Natural Person Signing Above wpuatamnm»cs form! �.��7y7�oo73 PASCO COUNTY DEVELOPMENT SERVICES PASO' 8731 Citizens Drive Date:7/24/2018, COUN-ry FLORll)A New Port Richey, FL M54 727-847-2411 * NOT A PERMIT ** Receipt#: 1769823 FEE DESCRIPTION ACCOUNT CODE UNITS INVOICE# FEE AMOUNT PAID RECEIPT# DATE Impact Fee Residential Solid 24503100-329010 34.00 1366541 $34,00 $34.00 1769823 6120/18 Waste Single Family TOTALS: $34.00 $34.00 Receipt# Paid By Check# CC Aut # Cashier ID Workstation Receipt Date Amt Paid 1769823 Check 01006009 545 BCCCP10W 06/20/2018 $34.00 Total Payments: $34.00 PRO Address Phone LENNAR HOMESC,�,C_ 11.._ Comments• SOLID WASTE While you will be paying your bill with Pasco County Development Services,the full amount of the credit card or a-check fees,Not shown above,is collected by First Billing payment services. vA MyReports/repofts//PASCOPROD/PASCO/ReceiptPOS V6,►pt 7/24/2018 Page 1 of I s . PASCO COUNTY, FLORIDA r Permit No. Date Permitted Builder Name/Owner Name Control# County Parcel No. � SubDiv: 1 ,?ddefl Address/Location SO:& L�,,_Af` b�ka t Classificationrrype of Use TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: zt 6D5_ Exempt ❑Yes ❑ No How Determined Impact Fee Amount $. 3 t Zone No. TAZ: SCHOOL IMPACT FEE Account (056) Single-Family Detached House Amount $ (057) Mobile Home (058) Other Residential 123) Collection Fee Exempt Yes Q No How Determined PARKS AND RECREATION FEE Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation Total f Zone TOTAL AMOUNT $ -7.(tt�•�kj Exempt ❑Yes ❑ No How Determined LIBRARY FEE Land Account Land Credit Land Total Facility Account Facility Credit Facility Total Exempt ❑Yes ❑ No How Determined Total Amount ` G RESOURCE FEE ERU TOTAL AMOUNT Prepared By Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY Acknowledgement below does not imply acceptance of concurrence,but simply receipt of-a copy of this form,placing the building permit owner on notice of this assessment and the conditions of payment for same. DATE RECEIVED BY RECEIPT NO. DATE BY Jacqueline Boges From: Nichole Spence(City of Zephyrhills Support)<support@zephyrhillsfl.zendesk.com> Sent: Wednesday, June 6, 2018 2:09 PM To: Jacqueline Boges Subject: [FATHOM] Re: 3076 Kresterbrooke Lane by#19727 ##- Please type your reply above this line -## Your request (#217603) has been updated. REPLY TO THIS EMAIL or click the link below: https://zephyrhilisfl.zendesk.com/hc/requests/217603 ................................................................................................................................................................................................................................................................................................................................................................................. j Nichole Spence (City of Zephyrhills Support ) Jun 6, 1 1 :08 AM MST Account # 2992439 has been created, service order to follow once mapping has been completed. Best Regards, Nichole I FATHOM Support . ................................................................ ................................................................................................................................................ ................................................................................................... ................................. Jacqueline Boges L Jun 1, 5:10 AM MST full service 3076 kresterbrooke lane bpAr9 27Vw r , kwer , water meter This email is a service from City of Zephyrhills Support . 1 Lennar Homes-3076 Kresterbrooke Lane,2005 sq ft - Column ts SO. FEET PRICE MAIN OR LIVING: 2,005 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 225,863.25 FEE SHEET $ 1,170.00 ADDRESS $ 30.00 DRIVEWAYJ $ 45.00 BUILDING: $ 1,268.40 ELECTRICAL: $ 263.25 PLUMBING: $ 175.50 MECHANICAL: $ 122.85 SUB-TOTAL $ 1,830.00 TOTAL $ 1,830.00 SEWER: $ 2,090.00 WATER: $ 1,010.00 IRRIGATION: $ - TOTAL: $ 3,100.00 WATER METER: $ 473.78 IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 5,957.13 PARK IMPACT FEES $ 769.56 SIF'S: $ 7,128.00 100.0% $ 7,128.00 1.0% $ 71.28 TOTAL: $ 7,199.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 17,557.97 ' ' ' . . . Jacqueline From: City of Zephyrhills Support<support@zeph�rhillsfl.zendesk.com> Sent: Friday, June 1, 2018 8:10 AM To: Jacqueline Boges Subject: [Request received] 3076 Kresterbrooke Lane bp#19727 ##- Please type your reply above this line -## Hello Jacqueline Boges We are working to resolve your request promptly and will keep-you updated. One of our Support Analysts will keep you updated on the progress of your request. Best Regards, FATHOM Support Team TO ADD ADDITIONAL COMMENTS, reply tn this email or click the link below: -_--____-........ ----------_--__'_----'_---------__--'__---____'_'_. _'___.......... Jacqueline B0ges � ' - - Jun l, 5]0AM MST full service 3076 kresterbrooke lane bp#l97J7water , sewer . water meter This email is a service from City ofZephyrhi|ls Support . - Jacqueline Boges From: Nichole Spence(City of Zephyrhills Support,) <support@zephyrhillsfl.zendesk.com> Sent: Monday, June 11, 2018 2:28 PM To: Jacqueline Boges Subject: [FATHOM] Re: 3076 Kresterbrooke Lane by#19727 4-Please type your reply above this line-44 Your request(#217603)has been solved.TO REOPEN THIS REQUEST,reply to this email or click the link below: https://zgphyrhillsfl.zendesk.com/hc/requests/217603 .................................................................................................................................................................................................................................................................................................................................................................................... Nichole Spence(City of Zephyrhills Support) L Jun 11. 11:28 AM MST Service order for meter install created. Best Regards, Nichole FATHOM Support ....................................................................................................................................................................................................................................................................................................................................................................................... Nichole Spence (City of Zephyrhills Support) Jun 6, 11:08 AM MST Account# 2992439 has been created, service order to follow once mapping has been completed. Best Regards, Nichole I FATHOM Support .................................................................................................................................................................................................................................................................................................. ...................................................................... (I Jacqueline Boges `_ ; Jun 1, 5:10 AM MST full service 3076 kresterbrooke lane by 197,27 water , sewer , water. meter This email is a service from City of Zephyrhills Support. 1 • I LOU IOH j?N r City of ZephAlls' BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: r Date Received: —1" Site: fcrcz r-LajD Permit Type: �(i� r o 06 t Approved w/no comments:❑ Approved w/the below comments: Denied w/the below comments: ❑ This comment sheet shall be kept with the permit and/or plans. IOA Kalvin wit e —Plans Examiner Date Contractor an or Homeowner (Required when comments are present) ` ' . 81 City of Zephyrhills Permit Application Fax-83-780-002 Building Department Date Received Phone Contact for Permfttlnj .L 813 363 2891 ' . Owner's Name ��m�Phonnmum�w � ` . . FL Owner's4600 ress Address o��p��m�� Fee Simple nuonmue,Namo Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS Lor# ouoo|wo|om Hidden River Phase One A p4moEL|o# 24-26-21-0100-00000-0730 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW cowom AOox\LT [---1 G|GN �—� �-� DEMOLISH . P INSTALL [ � REPAIR PROPOSED USE GFR �-1 COMM �---1 VTHEn TYPE orCONSTRUCTION BLOCK F-� p�A�e [---1 Grs�� DESCRIPTION OpWORK amily Residence Pool/Screen Enclosure/Fence BUILDING SIZE :�] mP FOOTAGE L���� � HEIGHT -OBUILDING 11 -65, VALUATION OF TOTAL CONSTRUCTION MECHANICAL 1$ VALUATION OF MECHANICAL INSTALLATION F--loAo h����| ROOFING F-� apsc �TY F--� OTHER � � �_� ��. FINISHED FLOOD YES O V � | � - - - - - - - - - - - - - - - BUILDER COMPANY Lennar Homes,LLC a|om/nons FEE nunns /dumuo umenua# sLsonaCIxNEd:MO:n On Electric, Inc. SIGNATURE REGISTERED psEounnEN `�-�-�---- Address Lmeooe# PLUMBER OMPANy Bayonet.Plumbing, Heating &AC, Inc SIGNATURE RCEGISTERED �.// N_1 FEEcunnsx rmumse License# MECHANICAL COMPANY Bayonet Plumbing, Heating &AC, Inc SIGNA TURE s o �y!N_] FEE Cunnsx Address License*. OTHER COMPANY a|Gm/TuRs REGISTERED Y/vN rsscunnsN, Address License# x n u x o u m x m n x o n o n n u m n o o u u u w n n x o o x m n m no n n n x m u n u n n x m x m n nu o u x'm x n o o u x o o m n RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans wt Silt Fence installedi Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete seti of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, sanitary Facilities&I dumpster.Site Work Permit for all new projects.All commercial requirements must meet co mpliance SIGN PERMIT Attach Vq sets of Engineered Plans. **^°PROPERTY SURVEY required for all NEW construction. ' _ Fill out application completely. Owner&Contractor sign back o[application,notarized If over$2so0,o Notice of Commencement|orequired. kuc upgrades over$7nmN Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from ownerauthorizing same . OVER THE COUNTER PERMITTING (copy nf contract required) nemofs if shingles Sewers Service Upgrades /Vo Fannoa(P|uVaunmylFoumgW Driveways-Not over Counter if on public madways'peeuoROW ' - . ' . . NOTICE OFDEED : The undersigned understands that this permit may besubject which may be more restrictive thonCnunty-regukationo. The undersigned assumes responsibility for compliance with any applicable deed restrictions.UNLICENSED CONTRACTORS ANDAND �QCONTRACTOR ��RESPONSIBILITIES: |fthe' owner ha.a hired a contractor or oontnaotoruto'undertakevvork. thoymoybnraqu\nadtobe |icnnoedinacuordmnoevvithebataond |nca| regu\ediono. If the c�ntractor is not licensed eo required by |mw, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Fudhennone, if the owner hom hired o contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the oontnactor, that may be.an indication that hmio not properly licensed and is not entitled topermitting privileges in Pasco County. TRANSPORTATION lK0PAC77UT7L]T/ES |R0P��CT��N[� F�2S(�OROE ��E��OVERYFEES: The undersigned unden�onds that TmonepodaUonImpact F6�b and Recourse Recovery Fees may apply to the construction of new buildings, change of uoein existing bVi|dinga, or expansion of existing bui|dingu, as specified in Pasco County Ordinance number 80-07 and 00'07, as amended. The undersigned also undee*tands, that such fees, as may be due, will be identified st the time qf permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a"certificate of occupancy" nr final power release. |f the project does not involve a certificate of occupancy or hno| power re|eame, the fees must be paid prior to permit issuance. Furthermore, if Pomco County Water/Sewer Impact feamanadue. thaynnuatbepaidphortopermbiaouonoeinaccondanoewitheppUcob|mPeauoCnunb/ordinmncem. CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, memnmeodod): |f valuation of work io $2.GDO.00or more, | certify that |' the opp|imard, have boan provided with o copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. |f the applicant imsomeone other than the^mwnar". | certify that Ihave obtained a copy of the above described docurnentand promise in good faith to da|�er�to the"mwne�phort000mmen�ement. C0NTRACTOR'S/OVV0EPk'SJ4FF|D&V|T: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable |ovvo nsgU|sding construction, zoning and land development. Application is heneby,nnode to obtain a permit to do work and installation as indicated. I -certify that no work or installation has commenced prior to ioouano - ofa permit and that all work will be performed to meet standards of all laws regulating oonetructiqn. Courty and City codes, zoning nagu|aUpnn. and land development regulations in the jurisdiction. | also certify that | understand that the regulations nf other government agencies may apply to the intended work, and that it is nly responsibility to identify what actions | must take tobe in compliance. Such agencies include but are not limited to: - Department ofEnvirohmenta| Protection-Cypress Bayheadn. Wetland Areas and Environmentally Sensitive Lands, Water/Wastewater Treatment. - Southwest Florida VVober Management Diuthct48e|ka, Cypress Bayheodo, Wetland Ansao, Altering Watercourses. ' - Army Corps ofEnginoene-SeawaUa. Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-VVeUo, Wastewater Treatment, Septic Tanks, - ' UQEnvironmehla) Protection Agency-Asbestos abatement. ' Federal Aviation AutloritY-Runwmyo. | understand that the following restrictions apply to the use offill: - Use of fill io not allowed in Flood Zone"V° unless expressly permitted. ' |f the fill motaho| is to be used in Flood Zone "A", it in understood that e drainage plan addressing m "compenaaUng volume" will be submitted at time of permitting which is prepared by a pnzfenm(nna| engineer licensed by the State ofFlorida. - |f the fill material is to be used in Flood Zone "K in connection with o permitted building using stem wall construction, | certify that fill will be used only to fill the area within the stem wail. - |ffiU,moteda| is to be used in any area, | oadJv that use of such 5U will not odwaroo|y affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots |eeo than one (1) acre which are elevated bv fill, an engineered drainage plan inrequired. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. | understand that a separate permit may be required for electrical work, p|unlbing, signu, vveUo, pon|s, air conditioning, gmn, or other installations not specifically included in the application. A permit issued oho|| be construed to be n license to proceed with the work and not an authority to vio|oto, cancel, a|ter, or set asid*e any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid - unless the work authorized by such permit is commenced within nix months of permit issuance, or if work authorized by the-permit is suspended or abandoned for o periodof six(G) months after the time the work iocommenced. An extension may be requonted, in writing, from the Building Official for o period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned., WARNING TO OWNER: YOUR-FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. OWNER OR AGENT ZZ CONTRACTOR Subscribed and sworn to(or affirintgbefore me this Subscribed and sworn to(ff affirmed his WEo is/are personally known to me or-h 81have pFeduGed Who is/are personally known to me c asidentification. as identification. ___Notary Public _____Notary Public Commission No. FF98537 Commission= No. FF98537 EliouM.Holleran 8lisouM.Holleran Name v,Notary mnoo.printed mommvv"` - Name m Notary typed,printed or stamped ` _ _ Singe Fame y Dwe ing Pla n Review.Comments 1.� T.F.E. shall be a minirnum:of.8" above the road elevation and an engineered site plan. . 2. -Lots shall be graded to.comply with R401'.3 .of the-F.B.C: 3. Compaction test required:if 24" or more of fill dirt is.brought in-at any.one place: .: 4. Tie in survey required before pouring concrete. 5. Driveways require a R_:O.W. use permit:. All 4 sides of driveway.thra the sidewalk shall have expansion matenal.. 6.. All setbacks.'shall be met.:. - 7.- All property:markers shall be,uncovered and marked at time of first.'inspection: 8. :All A.D.A.-requirements shall be met.: 9. No electric;plumbing,mechanical;.or-fraining shall be covered without an:inspection and -approval first.- 1 O.All Garages shall:comply_.with-section R302:6 of the:RB:C.:(Fire-S:eparation). 11. Appliances:shall not be installed in:a location where subject to.ineichanical damage unless protected:byapprovedbarriers. M303.4'of.the.F.B:C 12. Water heaters shall comply:with secti6nT607.3 of the F.B.C. 13.'Foundation sup poits for'A/C.units shall be raised at least 3" above finished grade. M1308.1. 14. Return air in all.bedrooms. F.B.C. M1620.4 . 15. Smoke detectors' 'are to be installed=iri a6c6rdanee:with:R313:1 of the:F.B.C. 16-.:A11 glazing requirements are..to be in accordance with R308.4.of the F.B.C. 17. All means.of egress are to be in:accordance with R311`6f the F.B.C., 18. "Green gypsurn-N and shall riot be used:as.a backer.iri showexs or tubs.'R702.4:2 F.B.C: 19..Coinbination-type'AFCI breakers are.required.at all,locations requiring an AFCI.type breaker: 20.-Carbon monoxide alarms will.be required in new:construction that uses fossil-burning heating or appliances or an attached garage:_ They shall be installed in aecordance with.the F.B.C: 21. All plumbing, mechanical,4nd electrical shall b- separate from unit to unit. Thisiricludes all. underground plumbing and electric: 22. 'All2011:N:E:C: Codes-will-be enforced: 23.Tamper- Resistant Receptacles in accordance with 406.11 of the 2011 N.E:C .24 .In accordance:with the Land Development.Code-_lots shall be sodded before final of least 10 feet'around the structure: 25. A.cony of the enerjzy cacls shall be with yermitat all times. 26 Copy of final insulation report shall be.tirovided with.permit-before.fnaL F.F.E.-Finished Floor Elevation F:B:C=Florida Building Code 6t'Edition. R.O:W Right'of Way A.D.A.-Americans with.Disabilities Act N.E.C.-National Electric:Code(2011). PLOT PLAN SKETCH ONLY NOT A BOUNDARY SURVEY SEC. 24 TWP. 26 S, RNG. 2 E. BEARING BASIS: LOT 73 HIDDEN RIVER PHASE ONE B NORTH BOUNDARY OF SUBJECT PLAT BEING S 89'40'43" E PASCO COUNTY, FLORIDA.- THIS SURVEY IS SUBJECT TO ANY FACTS THAT MAY BE DISCLOSED BY A FULL AND ACCURATE ON LOT AREA CALCULATIONS TITLE SEARCH. ALSO SUBJECT TO SETBACKS, LOT =_6600.00 _SQ. FT. EASEMENTS AND RESTRICTIONS OF RECORD. LIVING AREA = 1556 _SQ. FT. ENTRY = 4Q __SQ. FT. o UNDERGROUND FOOTER, STEM WALL, AND GARAGE = _4a6--SQ. FT. UNDERGROUND UTILITIES ARE NOT LOCATED OR, COVERED LANAI =--tV-A--SQ. FT. II SHOWN. PATIO = 23 SQ. FT. CONC. DRIVE =__456__SQ. FT. DO NOT SCALE THIS PRINT. DIMENSIONS AND A/C & CONC PAD = _9 SQ. J NOTES TAKE PREFERENCE. FT. PRIVATE SIDEWALK = 28 SQ. FT. DESCRIPTION NOT CONTAINING PLAT BOOK AND IMPERVIOUS =_3_8 % PAGE INDICATES THAT PLAT IS IN = 2518 SQ. FT. t PRELIMINARY STAGE AND IS SUBJECT TO SOD =A4082 -SQ. FT. CHANGE AND/OR REVISION. OFF LOT AREA CALCULATIONS CERTAIN DATA SHOWN HEREON BASED ON RIGHT OF WAY =_ 720.00_SQ. FT. ENGINEERING PLANS PROVIDED BY CLIENT. DRIVE APRON = 144 _SQ. FT. PUBLIC SIDEWALK = 24� SQ. FT. STRUCTURE TIES SHOWN HEREON DENOTES SOD = 336 SQ. FT. MEASUREMENT FROM FORM BOARDS/FOUNDATION TO PROPERTY LINE. TOTALS * = 10' DRAINAGE/UTILITY EASEMENT AREA =--7320.00 SQ. FT. ** = 5' DRAINAGE EASEMENT DRIVEWAY =_ 600 -SQ. FT. SIDEWALK =_-Z!LE!--_SQ. FT. SOD =__4418 __SQ. FT. NG PRELIMINARY DRAWING: THIS PLAN IS FOR PERMITTING PURPOSES CONSTRUCTION.ONLY, NOT FOR ALL DIMENSIONS BEFORE ANY CONSTRUCTION. \�f. pP LEGEND: �CJ��oot eo �SORI��/ o° f-�= PROPOSED DRAINAGE FLOW (00.00) = PROPOSED GRADE E-00.00 = EXISTING GRADE NOTES: / . z < (71.10) LOT GRADING TYPE = A / pa PLAT PROPOSED PAD ELEVATION = i E 6p BOUNDARY FRONT SETBACK = 20' a'. n�yy� �yoa SIDE SETBACK = 10' o .• 0 ��� so\ REAR SETBACK = 10' CO LOT 74 0IA PRM(P) O (nP) 2 QROP\opa� \\\ P g\ O v. �� GE \\ 00. 1JCr�, o; G\., \\ 0 LOT 72 OLA. Apo pPTo \\ PLAT O p ss•, \ BOUNDARY 00+ �poo .�PI LOT 73 \\ �'' `•.•�� (7D.0 0 ) 0. �„ vy TRACT "B" LOT 71 S HIDDEN RIVER PHASE ONE A (PLAT BOOK 74, PAGES 101-121) WETLAND CONSERVATION AREA PROPOSED: LOWEST FLOOR ELEVATIONS: I LIVING AREA: 72.35' PLAT GARAGE AREA: 71.81' DESCRIPTION: BOUNDARY ELEVATIONS REFERENCED TO LOT 73, MAP OR PLAT ENTITLED "HIDDEN RIVER PHASE ONE B", NATIONAL GEODETIC VERTICAL AS RECORDED IN PLAT BOOK ___, PAGES ___ THROUGH DATUM OF 1929. MEAN SEA OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. LEVEL= 00.00 FT. APPARENT FLOOD HAZARD ZONE: 'Y' COMMUNITY PANEL NO. 120230 0460 D EFFECTIVE DATE: 9/30/1992 LEGEND: (C)= CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, rk= CENTERLINE, A/C= AIR CONDITIONER, B/C= BACK OF CURB, C/S= CONCRETE SLAB, CH= CHORD, CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= COVERED, E/P= EDGE OF PAVEMENT, ESM'T= EASEMENT, F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE, 'FIR= FOUND IRON ROD, FN&D= FOUND NAIL & DISK, FPP= FOUND PINCHED PIPE, LFE= LOWEST FLOOR ELEVATION, MAS.= MASONRY, OR= OFFICIAL RECORD BOOK, PB= PLAT BOOK, PCP= PERMANENT CONTROL POINT, PRM= PERMANENT REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & CAP No. 4493, SN&D= SET NAIL & DISK, TBM= TEMPORARY BENCHMARK, U P= UTILITY POLE, W F= WOOD FENCE, R = RADIAL JOHN R.BEACH&ASSOCIATES,INC. Drawn By: SMS Square Feet: 6600.00 t LENNAR HOMES SURVEYORS AND MAPPERS Checked By: 911 WEST ST. PETERSBURG DRIVE JRB ONE OLDSMAR, FLORIDA 34677 WAY (813) 854-1276 FAX (813) 855-8370 Scale: 1"=30' . NOT VALID WITHOUT THE SIGNATURE AND Dote of Survey: THE ORIGINAL RAISED SEAL OF A FLORIDA PLOT PLAN 03/22/2018 RTM J . BEACH DATE LICENSED SURVEYOR AND MAPPER XLORIDA R-BO. LAND SURVEYOR No. 2984 LB 4493 Revisions: � .q w.g. •L T G —A ° •1?, �"" � r ,' �`.. \� '.:.' — •!,,.fir R �1�� $ I FFEL 74 49 -t - ,tr •� J.w A i . 49 71 +#1 .44 t` r �f4 FFEL rim FF EL F 7 70 e FF EL 46 FF EL 72.19/ I� q" 47to 48 ;. .000 MEL 49 50 Alo 1.73 Wl EL 66 63 A 71. E f FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name:_ 1551 B1 sf ADS Carrier Builder Name: Lennar Homes Street: 3076 Kresterbrooke Lane Permit office: City of Zephyrhills City,State,Zip: FL, Permit Number: J f1 Z7 Owner: Lennar Homes Jurisdiction:611 00 Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1497.3 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1176.00 ft2 b.Frame-Wood,Adjacent R=11.0 321.33 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 3 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (1555.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1555.00 ft2 6. Conditioned floor area above grade(ft2) 1555 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(104.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 311 a. U-Factor: Dbl,U=0.54 55.00 ft2 SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.56 33.33 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 24.0 SEER:15.50 c. U-Factor: Dbl,U=0.56 16.00 ft2 SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency d. U-Factor. N/A ft2 a.Electric Heat Pump 24.0 HSPF:9.00 SHGC: Area Weighted Average Overhang Depth: 1.319 ft. Area Weighted Average SHGC: 0.309 14.Hot water systems, 8. Floor Types (1555.0 sqft.) Insulation Area a.Electric Cap:40 gallons EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1555.00 ft2 b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.067 Total Proposed Modified Loads: 50.56 PASS Total Baseline Loads: 50.93 I hereby certify that the plans and specifications covered by Review of the plans and Te SxT' this calculation are in.com liance with the Florida Energy specifications covered b this d P 9Y P Y Code. calculation indicates compliancew J�aveGal>'tcGt with the Florida Energy Code. PREPARED BY: Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 I hereby certify that this building,as designed, is in compliance Florida Statutes. ,+, •• with the Florida Energy Code. Op. � . f jM11 ; OWNER/AGENT: MAY O 3 2010 BUILDING FFICIAL: / DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoois, tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.040 Qn for whole house. 5/1/2018 8:18 AM EnergyGaugeO USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 4 r j FORM 14405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 1551 B1 sf ADS Carrier Builder Name: Lennar Homes Street: 3076 Kresterbrooke Lane Permit office: City of ZephyrhiIls City,State,Zip: FL, Permit Number: Owner: Lennar Homes Jurisdiction:611600 Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1497.3 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1176.00 ft2 b.Frame-Wood,Adjacent R=11.0 321.33 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 3 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (1555.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1555.00 ft2 6. Conditioned floor area above grade(ft2) 1555 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(104.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 311 a. U-Factor: Dbl,U=0.54 55.00 ft2 SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.56 33.33 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 24.0 SEER:15.50 c. U-Factor: Dbl,U=0.56 16.00 ft2 SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 24.0 HSPF:9.00 SHGC: Area Weighted Average Overhang Depth: 1.319 ft. J Area Weighted Average SHGC: 0.309 14.Hot water systems 8. Floor Types (1555.0 sqft.) Insulation Area a.Electric Cap:40 gallons EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1555.00 ft2 b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.067 Total Proposed Modified Loads: 50.56 PASS Total Baseline Loads: 50.93 hereby certify that the plans and specifications covered by Review of the plans andT1 .Sx1gT;. .this calculation are in compliance with the Florida Energy specifications covered by this 'd� 0, Code. calculation indicates compliance + with the Florida Energy Code. PREPARED BY: 'Dave Aupich Before construction is completed DATE: this buildingwill'be inspected for P compliance with Section 553.908 I herebycertify that this building,as designed,is in compliance Florida Statutes. fY 9 9 P with the Florida Energy Code. OWNER/AGENT: MAY O 3 2018 BUILDING OF ICIAl J DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.040 Qn for whole house. 5/1/2018 8:18 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 4 FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 1551131 sf ADS Carrier Builder Name: Lennar Homes Street: 3076 Kresterbrooke Lane Permit office: City of Zephyrhills City,State,Zip: FL, Permit Number: Owner. Lennar Homes Jurisdiction:611600 Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1497.3 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1176.00 ft2 b.Frame-Wood,Adjacent R=11.0 321.33 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 3 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (1555.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1555.00 ft2 6. Conditioned floor area above grade(ft2) 1555 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(104.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 311 a. U-Factor: Dbl,U=0.54 55.00 ft2 SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.56 33.33 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 24.0 SEER:15.50 c. U-Factor: Dbl,U=0.56 16.00 ft2 SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 24.0 HSPF:9.00 SHGC: Area Weighted Average Overhang Depth: 1.319 ft. Area Weighted Average SHGC: 0.309 14.Hot water systems 8. Floor Types (1555.0 sqft.) Insulation Area a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 1555.00 ft2 b. Conservation features EF:0.950 b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.067 Total Proposed Modified Loads: 50.56 PASS Total Baseline Loads: 50.93 hereby certify that the plans and specifications covered by Review of the plans and :DYIE ST, ? this calculation are in compliance with the Florida Energy • specifications covered by this = p Code. calculation indicates compliance ,,, With the Florida Energy Code. Dave Aup cG� �... PREPARED BY: Before construction is completed DATE: this building will be inspected for E7 compliance with Section 553.908 , hereby certify that this building,as designed, is in compliance Florida Statutes. Al with the Florida Energy Code. CODA _ OWNER/AGENT: MAY O 3 2018 BUILDING OFFICI L: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.040 Qn for whole house. 5/1/2018 8:18 AM EnergyGaugeO USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 4 {' 1 FORM R405-2017 PROJECT Title: 155161 sf ADS Carrier Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1555 Lot# Owner Name: Lennar Homes Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: Lennar Homes Rotate Angle: 45 Street: Permit Office: Cross Ventilation: County: Pasco Jurisdiction: Whole House Fan: City,State,Zip: , Family Type: Single-family FL, New/Existing: New(From Plans) Comment: FBC 2017 CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V/ Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Tampa FL TAMPA_INTERNATI 39 91 70 75 645.5 54 Medium BLOCKS Number Name Area Volume 1 Blockl 1555 12440 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1555 12440 Yes 4 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio Main 134 ft 0 1555 ftZ 0.3 0 0.7 ROOF y Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1684 ftZ 0 ft2 Medium 0.85 No ;0.9 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 1555 ftZ N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) Main 30 Blown 1555 ftZ 0.11 Wood 5/1/2018 8:18 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 4 FORM R405-2017 WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 N=>NE Exterior Concrete Block-Int Insul Main 4.0999 20 8 160.0 ft2 0 0.600000 0 2 E=>SE Exterior Concrete Block-Int Insul Main 4.0999 54 8 432.0 ft2 0 0.600000 0 _ 3 S=>SW Exterior Concrete Block-Int Insul Main 4.0999 34 8 272.0 ft2 0 0.600000 0 4 W=>NW Exterior Concrete Block-Int Insul Main 4.0999 33 8 264.0 ft2 0 0.600000 0 5 N=>NE Garage Frame-Wood Main 11 19 8 8 157.3 ft2 0 0.01 0 _ 6 W=>NW Garage Frame-Wood Main 11 20 6 8 164.0 ft2 0 0.01 0 7 S=>SW Exterior Concrete Block-Int Insul Main 4.0999 6 8 48.0 ft2 0 0.600000 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N=>NE Insulated Main None .2 3 6 8 20 ft2 2 N=>NE Wood Main None .4 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered orientation(=>)changed to Worst Case. / Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N=>NE 1 Metal Low-E Double Yes 0.56 0.28 N 16.0 ft2 1 ft 0 in 4 ft 0 in Drapes/blinds None 2 E=>SE 2 Metal Low-E Double Yes 0.54 0.31 N 16.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds None 3 S=>SW 3 Metal Low-E Double Yes 0.54 0.31 N 16.0 ft2 1 ft 0 in 0 ft 10 in Drapesiblinds None 4 S=>SW 7 Metal Low-E Double Yes 0.56 0.32 N 33.3 ft2 2 ft 0 in 0 ft 4 in Drapes/blinds None 5 S=>SW 3 Metal Low-E Double Yes 0.54 0.31 N 23.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 408 ft2 408 ft2 40 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse. Proposed ACH(50) .000356 1451.3 79.68 149.84 .2669 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ None HSPF:9 24 kBtu/hr 1 sys#1 5/1/2018 8:18 AM EnergyGaugeO USA 7 FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 4 FORM R405-2017 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER:15.5 24 kBtu/hr 720 cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 40 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS / —Supply— —Return— Air CFM 25 CFM25 HVAC# V/ # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 311 ft2 Main 77.8 ft2 Proposed Qn Main —cfm 62.2 cfm 0.04 0.60 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Julr Coo Jun 0 Dec Heating HJan Jan Pq Feb Mar Apr May rleb Mar Apr May Jun rl Jul LX�A ct ug JXJ Sep OOct Nov Dec ct lxj Nov Nov DecVenting Jan Feb X Mar Jun Jul [[[[ Aug Sep Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 I 5/1/2018 8:18 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 4 . FOkM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the EnergyPerformance Index,the more efficient the home. FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1176.00 ft2 b.Frame-Wood,Adjacent R=11.0 321.33 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 3 d.N/A R= ft2 10.Ceiling Types Insulation Area 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1555.00 ft2 6. Conditioned floor area(ft2) 1555 b.N/A R= ft2 _ 2 7. Windows" Description Area 11 Ducts R R ft2 a. U-Factor: Dbl,U=0.54 55.00 ft2 SHGC: SHGC=0.31 a.Sup:Attic,Ret:Main,AH:Main 6 311 b. U-Factor: Dbl, U=0.56 33.33 ft2 SHGC: SHGC=0.32 12.Cooling systems kBtu/hr Efficiency c. U-Factor: Dbl,U=0.56 16.00 ft2 a.Central Unit 24.0 SEER:15.50 SHGC: SHGC=0.28 d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 24.0 HSPF:9.00 Area Weighted Average Overhang Depth: 1.319 ft. Area Weighted Average SHGC: 0.309 8. Floor Types Insulation Area 14.Hot water systems a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 1555.00 ft2 EF:0.95 b.N/A R= ft2 c.N/A R= ft2 b. Conservation features None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed;`' •_=?,,�r°s+, , based on installed Code compliant features. _ rn,,,' r Builder Signature: Date: 05/01/18t AV *..' � . Address of New Home: 3076 Kreslerbrooke Lane City/FL Zip:Zephyrhills,FL 33540 *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 5/1/2018 8:19 AM EnergyGauge®USA-FlaRes2017 -Section R405.4.1 Compliant Software Page 1 of 1 Building Anal Job: 1551B1 sf ADS Carrier g YSIS Date: 511/2018 Entire House By: Dave BAYONET PLUMBING COOLING HEATING Project Information For: Lennar Homes Design C• • • Location: Indoor: Heating Cooling Tampa International AP, FL, US Indoor temperature(°F) 70 75 Elevation: 10 ft Design TD (°F) 39 16 Latitude: 28°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 34.7 54.7 Dry bulb(°F) 31 91 Infiltration: Daily range(°F) - 14 ( L ). Method Simplified Wet bulb(°F) - 77 Construction quality Semi-tight Wind speed (mph) 15.0 7.5 Fireplaces 0 Component Btuh/ft2 Btuh % of load Walls 5.6 6121 28.1 Ducts Glazing 30.2 3154 14.5 wan nfiltration Doors 23.5 480 2.2 Ceilings 1.3 1950 8.9 Floors 3.7 5815 26.7 Infiltration 1.9 2372 10.9 Ducts 1901 8.7 Floors Humidification 0 0 Glazing Ventilation 0 0 IDoorm Adjustments 0 Ceilings Total 21794 100.0 Component Btuh/ft2 Btuh % of load Walls 2.8 3045 16.2 Walls Glazing 59.1 6179 32.9 Internal Gains Doors 18.4 376 2.0 Ceilings 1.7 2697 14.4 Floors 0 0 0 Infiltration 0.4 531 2.8 I: . . Ducts Ducts 2200 11.7 Ventilation 0 0 Internal gains 3750 20.0 Glazing Infiltration Blower 0 0 Adjustments 0 Ceilings Total 18777 100.0 Doors Latent Cooling Load=2492 Btuh Overall U-value= 0.103 Btuh/ft2-°F Data entries checked. - wrightsoft® 2018-May-01 08:12:20 ^�^•� �wa- Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 ...equipment\1551 sf ADS template 2ton Carrier.rup Calc=MJ8 Front Door faces:NW Job: 1551B1 sf ADS Carrier Project Summary Date: 5/1/2018 Entire House By: Dave BAYONET PLUMBING COOLING HEATING Project Information For: Lennar Homes Notes: Design Information Weather: Tampa International AP, FL, US Winter Design Conditions . Summer Design Conditions Outside db 31 OF Outside db 91 OF Inside db 70 OF Inside db 75 OF Design TD 39 OF Design TD 16 OF Daily range ' L Relative humidity 50 % Moisture difference 55 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 19893 Btuh Structure 16577 Btuh Ducts 1901 Btuh Ducts 2200 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 21794 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 18777 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 2102 Btuh Ducts 390 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling (none) Area(ftz) 1555 1555 Equipment latent load 2492 Btuh Volume(ft') 12700 12700 Air changes/hour 0.26 0.14 Equipment Total Load (Sen+Lat) 21269 Btuh Equiv.AVF (cfm) 55 30 Req. total capacity'at 0.85 SHR 1.8 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade Trade Model 25HBC524AO0300 Cond 25HBC524AO0300 AHRI ref 9154943 Coil FB4CNP025L AHRI ref 9154943 Efficiency 9 HSPF Efficiency 12.5 EER, 15.5 SEER Heating input Sensible cooling 20400 Btuh Heating output 24000 Btuh @ 47'F Latent cooling 3600 Btuh Temperature rise 27 OF Total cooling 24000 Btuh Actual air flow 800 cfm Actual air flow 800 cfm Air flow factor 0.037 cfm/Btuh Air flow factor 0.043 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.88 Capacity balance point= 30 OF Backup: n/a n/a Input= 0 kW, Output= 0 Btuh, 100 AFU,E Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -Fk wrightsoft• 2018-May-01 08:12:20 °�^ Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 ..equipment\1551 sf ADS template 2ton Carrier.rup Calc=MJ8 Front Doorfaces:NW Manual S Compliance Report Job: 1551B1 sf ADS Carrier Date: 511/2018 Entire House By: Dave BAYONET PLUMBING COOLING HEATING Project Information For: Lennar Homes Cooling Equipment Design Conditions Outdoor design DB: 91.3°F Sensible gain: 18777 Btuh Entering coil DB: 75.7°F Outdoor design WB: 77.3°F Latent gain: 2492 Btuh Entering coil WB: 62.8°F Indoor design DB: 75.0°F Total gain: 21269 Btuh Indoor RH: 50% Estimated airflow: 800 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: SplitASHP_ Manufacturer: Carrier Model: 25HBC524A00300+FB4CNP025L Actual airflow: 800 cfm Sensible capacity: 20400 Btuh 109% of load Latent capacity: 3600 Btuh 144% of load Total capacity: 24000 Btuh 113% of load SHR: 85% Heating Equipment Design Conditions Outdoor design DB: 30.8°F Heat loss: 21794 Btuh Entering coil DB: 69.6°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: SplitASHP Manufacturer: Carrier Model: 25HBC524A00300+FB4CNP025L Actual airflow: 800 cfm Output capacity: 18304 Btuh 84% of load Capacity balance: 30 OF Supplemental heat required: 3490 Btuh Economic balance: -99 OF Backup equipment type: Elec strip Manufacturer: n/a Model: n/a+n/a Actual airflow: 800 cfm Output capacity: 0 kW 0% of load Temp. rise: 0 OF Meets all requirements of ACCA Manual S. - wrightso ® 2018-May-01 08:12:20 M�� ftAv���a� --- ---- Right-Suiteral Universal 2018 18.0.16 RSU05714 Page 1 ...equipment\1551 sf ADS template 2ton Carrierrup Calc=MJB Front Door faces:NW 5335 - 8TH STREET (813)780-0020 CERTIFICATE OF OCCUPANCY Address: 3076 KRESTERBROOKE LANE Owner: LENNAR HOMES LLC ZEPHYRHILLS, FL. 4600 W. CYPRESS ST STE 200 Subdiv: HIDDEN RIVER TAMPA, FL 33607 Parcel: 24-26-21-0100-00000-0730 Work Type: 101-NEW CONST/SFR Construction Type: NOT APPLICABLE ❑ Sprinklers Use Classification: NOT APPLICABLE Permit Number: 19727 Date: 9/21/2018 ISSUED BUILDI OFFICIAL : WATER MUST BE CHANGED OVER WITHIN 10 DAYS OF ISSUANCE GARBAGE DEPOSIT MUST BE APPLIED FOR PRIOR TO ISSUANCE