Loading...
HomeMy WebLinkAbout18-19803 CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 19803 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL PERMIT INFORMATION - LOCATION INFORMATION Permit#:19803 Issued: 6/25/2018 Address: 3107 KRESTERBROOKE LANE Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 225,863.25 Total Fees: 17,557.97 Subdivision: HIDDEN RIVER Amount Paid: 17,557.97 Date Paid: 6/25/2018 Parcel Number: 24-26-21-0100-00000-1160 CONTRACTOR INFORMATION OWNER INFORMATION Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC Addr: 4600 W. CYPRESS ST STE 200 Address: 4600 W CYPRESS ST STE 200 TAMPA, FL. 33607 TAMPA FL 33607-4099 Phone: (813)574-5743 - Lic: Phone: 813-574-5700 Work Desc: CONSTRUCT SINGLE FAMILY 2,005 SQ FT APPLICATION FEES BUILDING FEE 1,268.40 ELECTRICAL FEE 263.25 PLUMBING FEE 175.50 MECHANICAL FEE 122.85 WATER CONNECTION RESIDENT 1,010.00 SEWER CONNECTION RESIDEW 2,090.00 WATER METER RES 3/4" 473.78 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE NEW 7,128.00 SCHOOL-SFR NEW 1% 71.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32 �l S L Inspections Required FOOTER 2ND ROUGH PLUMB MISC INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRA TORS SIGNATURE PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIOlf CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER s� = PASCO COUNTY, FLORIDA Permit No. �� Date Permitte Z Builder Name/Owner Name t— 14�e� jUC Control# , County Parcel No. 2 z __/0J1/&bDiv: Address/Location 3 t'd 7 Ltf` S L?t 1 r oo e f Classificatlon(rype of Use ;v TRANSPORTATION IMPACT FEE . Rate: Sq.Ft Unit: 2- Exempt ❑Yes ❑ No How Determined Impact Fee Amount $.31 G 32• Zone No. TAZ: SCHOOL IMPACT FEE Account (056) Single-Family 1)etached House Amount (057) Mobile Home (058) Other Residential 123) Collection Fee Exempt [� Yes ❑ No How Determined PARKS AND RECREATION FEE Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation Total 7 Zone TOTAL AMOUNT $ ' /"M Exempt ❑Yes ❑ No How Determined LIBRARY FEE Land Account Land Credit Land Total Facility Account Facility Credit Facility Total Exempt ❑Yes ❑ No How Determined Total Amounve- RESOURCE FEE ERLI TOTAL AMOUNT Prepared By Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO.COUNTY Acknowledgement below does not Imply acceptance of concurrence,but simply receipt of a copy of this form,placing the building permit owner.on notice of this assessment and the conditions of payment for same. DATE RECEIVED BY RECEIPT NO. DATE BY 24-26-21-0100-00000-1160 1 Pasco County Property Appraiser Page 1 of 1 r , Data Current as Of: Weekly Archive - Monday, June 11, 2018 Parcel ID 24-26-21-0100-00000-1160 (Card: 001 of 001) Classification 00 - Vacant Residential Mailing Address Property Value LENNAR HOMES LLC `°Ag Land $0 4600 W CYPRESS ST STE 200 Land $28,473 TAMPA FL 33607-4099 Building $0 Physical Address Extra Features $0 3107 KRESTERBROOKE LANE ZEPHYRHILLS, FL 33540 3ust Value $28,473 Legal Description (First 4 Lines) Assessed (Non-School Amendment 1) $28,473 HIDDEN RIVER PHASE ONE B PB 76 PG 077 LOT 116 Taxable Value $28,473 OR 9737 PG 3770 3urisdiction City of Zephyrhills _ Land Detail (Card: 001 of 001) Line Use Description+Zo inin ng Units IType P Condition � aV-lue 1 , 0100 SFR MPUD 6,000.00 SF $4.50 1_00 $27,000 2 0100 SFR MPUD 1,637.00 SF $6.96 I 1.00 $1,473 Additional Land Information Acres 0.18 'Tax Area[ 30ZH CodeFEMA Residential Code HDRVLPI i [ Code 7 Building Information - Use 00 - Unimproved (Card: 001 of 001) Unimproved Parcel 00 - Unimproved Extra Features (Card: 001 of 001)__ _ Line ---]Description Year _IUnits V lue No Extra Features Sales History- See All 6 sales Previous Owner: DUNE FL LAND I SUB LLC Month/Year Book/Page Type ;DO 'Condition Amount 06/2018 9737 / 3770 Warranty Deed 05 Vacant Multi-Parcel Sale 09/2011 8606 / 3376 Warranty Deed 05 Vacant Multi-Parcel Sale 06/2010 8360 / 1872 Certificate of Title 12 Vacant $0 i I http://search.pascopa.com/parcel.aspx?parcel=2126240100000001160 6/15/2018 Lennar Homes-3107 Kresterbrooke Ln-2,005 sq ft o umn SQ. FEET PRICE MAIN OR LIVING: 2,005 $ •112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 225,863.25 FEE SHEET $ 1,170.00 ADDRESS $ 40.00 DRIVEWAY $ 40.00 BUILDING: $ 1,273.40 ELECTRICAL: $ 263.25 PLUMBING: $ 175.50 MECHANICAL: $ 122.85 SUB-TOTAL $ 1,835.00 TOTAL $ 1,835.00 SEWER: $ 2,090.00 WATER: $ 1,010.00 IRRIGATION: $ - TOTAL: $ 3,100.00 WATER METER: $ 473.78 IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 5,962.13 PARK IMPACT FEES $ 769.56 SIF'S: $ 7,128.00 100.0% $ 7,128.00 1.0% $ 71.28 TOTAL: $ 7,199.28 T I F'S: $: 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 171562.97 Sin le Famil Dwell* ; Y Plan.-Rev..iew.Convents l: .FYI. shall be a minimum.of-8" above:the road elevation and an engineered.site plan. 2. Tots.-shall be graded.to comply with R401.3 of the F.B.C: I. ;Coinpaetion test required.if 24" or more:of fill dirt is brought in:at any one place: 4. .Tie in survey required before pouring concrete.. 5._ Driveways require a R:O.W. use permit: All' driveway-sides of driveway-thrd the sidewalk shall have. expansion material: 6- Ail setbacks shall.be met.; 7. All.property:markers shall be,uncovered.and marked.at time'o f first,inspection: 8:: :All A.D.A. requirements.shall be met.: . 9.. No electric;plumbing,mechanical;.or framing shall be covered'without an.inspection and approval first. 10. All Garages shall comply:with:section R302:6:of the.F.B:C::(Fire-Separation). 11.Appliances:shall not:be installed in:a locationwhe're siibjectto,mechanical damage unless protected by approved barriers: M303A of the F. 12. Water heaters shallcompl:y:with section.P607.3.of the F.R.C. 13. Foundation supports for A/C.units shall be raised at Least T' above finished grade. M1308,1. 14.Return aii in all bedrooms.-F.B.C. M1620.4.: . 15: Smoke detectors are to be installed:in accordance with:R313.1 'of the:F.B.C. 16, A11 glazing requirements are:.to be in accordance with R308.4.of the F.B.C. 17. All means.of egress are to:be in:accordance with R311:6fthe F:B.C. :: 18. "Green gypsum board shall not be'.used:as a backer.in showers or tubs:R702.44:2 F.B.C, 19,Combination-type AFClbreakers are.required.at all,locations requiring an AFCl,type breaker: 20. Carbon monoxide-alarms:will.be required in,new construction that uses fossil-burning heating or appliances or an attached garage.:. They shall be.installed in accordance'with,the F.H.C. - 21. All plumbing,mechanical, and electrical shall:be separate from unit to unit: This includes all. underground plumbing and electric: 22., A112011X.E.C. Codes.will be enforced.. 23.Tamper=Resistant Receptacles in.accordance with 406.11 of the 2011 N:E:C 24: In accor-dance_.with the Zand:.Development Code, lots.shall be sodded before final at least-10:. :. feet around the.strucfure: 25 A.cvpV oft{ie eizei' y caclsahulL he with pertnit-at atl times - - 26 Copy of final-insulation repbrt-shall be.prbvided with,nernat-before,finial RRE.=Finished Floor Elevation, F.B:C Florida Building Code Oh Edition R:O:W.-Right.bf Way A.D.A.-Americans with Disabilities Act . N.E.C.-National Electric.Code(2011): ` 81 ' City of PerO� Application Fo�oa�oo�Oo ' Building ' Date Received -- mmxomnnm uuu � o Owner's Name Lennar Homes,LLC Owner Phone Number 813.574.5700 4600 .. . ' � FL 33607 Owner's Addrress ess � �x�nm,Phvnemvmben - NIA Fee Simple Titleholder Name I Owner Phone Number Fee Simple Titleholder'~~'~~~ JOB ADDRESS LOT# SuBomIS|om Hidden River Phase One P4mCEL|m* (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED w�mcowsrx AoD6ALT [---1 G|GN �-� �-� DEMOLISH 9[_�] INSTALL �_] REPAIR PROPOSED USE orn F-� COMM [---1 oTMER TYPE oFCONSTRUCTION BLOCK F-� FRAME [---1 GT�EL F-1 �-� ^---� �-^ DESCRIPTION mFWORK Single Family Residence/Pool/Screen Enclosure/Fence au|Lo|mG S|os U/R SF -GQ FOOTAGE����� J *s|mxr 1 story, .0BUILDl 11 VALUATION OF TOTAL CONSTRUCTION ��UELsoTm/cAL AMP PRQonsGSswERoY [-� vu*�E.C. `�-� �_�� - �yUpmMe|wo �� �-� ?60 �� �� U*� yMsoHAN|CAL VALUATION OF MECHANICAL INSTALLATION �� =EwS L�1 ROOFING F-1 SPECIALTY OTHEROTHER --R �� �IN|3HEoF�OORE�EVAT|ONG FLOOD OYES o U V | � - o0LDs o|GmAruRE REGISTERED LY/_N_] pssounns^ L_YIN_] Address 4600 Ucenoo# =Edmonson ELECTRICIAN COMPANY Electric, Inc. m|Gm/noRs I REGISTERED Y/ N ] ,ssoumnsN _ L_X2N�_] Address F1034 Skipper Road,Tarnl5a, FL 33613 License# lic PLUMBER ' SIGNATURE REGISTERED Y/ N_] pssounnsx Y2N_] ' Address ummvo# MECHANICAL COMPANY =Bayonet Plumbing,. Heating &AC, Inc SIGNATURE REGISTERED _Y/ N_] pssnunnsx ` xguneso uoenoo# ' o�xse COMPANY m|�m�n��� o L���N_� pssouune^ A��neo Ucenoa# xmxxmmoxmnxumnnmnnxmxxmxxxmxxuuxnmnxnnxxmnxumnxmnoxmxxuuxxuomonnxox RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal dote. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1dumpstar;Site Work Permit for hd| i 8orgepn400ts COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safe�Page;(1)set of Energy Forms.R-O-W Permit for new construction. ' Minimum ten<1V>working days after submittal date. Required onuUe.Construction Plans,0omnwoter Plans vl Silt Fence installed, Sanitary Facilities m1dumpoter.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach;V sets o(Engineered Plans. ~°pROpsnTY SURVEY required for oUNEmconstruction. Fill out application completely. 0vner&Contractor sign back of application,notarized n over$oan0,a Notice o,Commencement|erequired. (A/u upgrades over$7sVo) - Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy co contract required) . Remofs|fshingles Sewers Service Upgrades A/C Fonoou(P|mmunvey/Footage) Driveways-Not over Counter ifun public muUmsyx'neeuuROW � ' - ` NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance'with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended):- If valuation of work is $2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner" prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands, Water[Wastewater Treatment. - Southwest Florida--Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls, Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand,that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone W" unless expressly permitted: - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction, I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90) consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICFZQF COMMENCEMENT. FLORIDA JURAT(F.S. 117.03) OWNER OR AGENT CONTRACTOR Subscribed and sworn to(or a r d)be�fooree me this // - / Subscribed and sworn to or a Irmed)before me this / JU-Hpr-I O by nfkal /)LPL �/7`�L�/7/�/�� 30-Apr-18 by F 1 J Who is/are personally known to me or Who is/are personally known to me or hasihave predaeed as identification. as identification. Notary Public Notary Public Commission No. FF9853.7 Commission No. FF98537 Elissa M.Holleran Elissa M.Holleran Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped 1� 4WGIXiIAEll�lpl . ._- LIIdW - y 14rrmYa�nit�.11�ta94ilQ IIrnl d f?��taisP �jp�`8�dilhlll���Q �JI(o���11hi�i�a�d B,�dN7nar��de4voe;,ar�l�sar�,�pll ' � � �11111111111IIIIiiitillli�illi14111111111181111111111411141�4 2018103053 Fr;C 1956a51 Rec: 10.00 4 bs: 0.00 IT: 0.00 b6/19/2018 C. F. , Dpty Clerk �RULR S.0'FaEIL,Ph.D��.PRSCO CLERK 8 COCIPTROLLER i06OR BK 97// 3 PG Permit No. Parcel ID No, 24-26-21-0100-00000-1160 NOTICE OF COMMENCEMENT State of Florida Countyiof Pasco THE UNDERSIGNED hereby gives notice that improvement will be.made to certain real property,and in accordance with Chapter 713,Florida Statutes, the following information is provided in this Notice of Commencement: 1. Description of Property: Legal HIDDEN RIVER PHASE ONE B PB 76 PG 77 LOT 116 street Address: 3107 Ktesterbrooke Lane Zephryhiiis FL 33541 2. General Description of Improvement Single Family.Residence!Pool[Screen Enclosure/Fence f i 3. Owner Information: Lennar Homes,LLC. Name 4600 W Cypress St. Ste 200 Tampa FL. 33607 Address City State Interest in Property: Name of Fee Simple Titleholder: NIA (If other than owner) Address City State 4. Contractor: Lennar Homes, LLC Name 4600 W Cypress St, Ste 200 Tampa FL, 33607 Address City State Contractor's Telephone No.: 813.574.5700 5. Surety: NIA Name Address, City State Amount of Bond: $ Telephone No.: 6. Lender: NIA Name Address City State Lender's Telephone No.: 7. Persons within the.State of Florida designated by the.owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)(7),Florida Statutes: Lennar Homes, LLC Name 4600 W Cypress St, Ste 200 Tampa FL, 33607 Address City State Telephone Number of Designated Person: 813.574.5700 8. In addition to himself,the owner designates NIA of u to receive a copy of the!Lienors Notice as provided in Section 713.13(1)(b),Florida Statutes. Telephone Number of Person or Entity Designated by Owner: 9. Expiration date of Notice of Commencement is one year from the date of recording unless a different date is specified: WARNING TO OWNER: ANY PAYMENTS MADE BY.THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED .IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13,.FLORIDA STATUTES, AND CAN RESULT.IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR'PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE-OF COMMENCEMENT. STATE OF FLORIDA COUNTY OF PINELLAS Signature of Owner or Owner's Authorized Officer/Director/Partner/Manager Vice President Signatory's Title/Office The foregoing instrument was.acknowledged before me this 30 day of March ,by Steve Robert Smith as Vice President (type of authority,e. r.trustee,attorney in fact)for Lennar Homes LLC (name of party on be If of strument was executed). Personally Known 2 OR Produced Identification i] Notary Sig Type of Identification Produced Name(Print) Elissa Holleran Verification pursuant to Section 92.525,Florida Statutes. Under penalties of perjury,I declare that I have read the foregoing and that the facts stated in it are true to the best of-my knowledge and belief. WSW;HOLLi:RAN Signature of Natural Person Signing Above €�r ;�Crlmmlleiari�FF885831 wpdata/bcs/bcs form: '''p 'sondM'RimTmy.Fe1n[munnceSN4lS�nlg . FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 1551131 sf ADS Carrier Builder Name: Lennar Homes Street: 3107 Kresterbrooke Lane Permit office: Cl' f\Z�ephyrhills City,State,Zip: FL, Permit Number: r Owner: Lennar Homes Jurisdiction: 611600 Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1497.3 sqft.) Insulation Area 2. Single family or multiple family Single-family a.,Concrete Block-Int Insul,Exterior R=4.1 1176.00 ft2 b.Frame-Wood,Adjacent R=11.0 321.33 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 3 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (1555.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1555.00 ft2' 6. Conditioned floor area above grade(ft2) 1555 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(104.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 311 a. U-Factor: Dbl,U=0.54 - 55.00 ft2 SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.56 33.33 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.-Central Unit 24.0 SEER:15.50 c. U-Factor: Dbl,U=0.56 16.00 ft2 SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.,Electric Heat Pump 24.0 HSPF:9.00 SHGC: Area Weighted Average Overhang Depth: 1.319 ft. Area Weighted Average SHGC: 0.309 14.Hot water systems 8. Floor Types (1555.0 sqft.) Insulation Area a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 1555.00 ft2 b. Conservation features EF:0.950 b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.067 fi Total Proposed Modified Loads: 50.56. PASS Total Baseline Loads:, 50.93 I hereby certify that the plans and specifications covered by Review of the plans and T Sx this calculation are in compliance with the FloridaiEnergy specifications covered by this ;Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: Dave Aupich Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 °_: •, I herebycertify that this building,as de ' Florida Statutes. fy g, gned,is in compliance with the Florida Energy Code. G'O MAY 0 3 2010 '!' OWNER/AGENT: BUILDING OFFICIA . DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380,is not greater than 02040 Qn for whole house. 5/1/2018 8:18 AM EnergyGaugeO USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 4 FORM R405-2017 FLORIDA ENERGY EFFICIENCY:CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 1551 B1 sf ADS Carrier Builder Name: Lennar Homes Street: 3107 Kresterbrooke Lane Permit Office: City of Zephyrhills City,State,Zip: FL, Permit Number: Owner. Lennar Homes Jurisdiction: 611600 Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1497.3 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1176.00 ft2 b.Frame-Wood,Adjacent R=11.0 321.33 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 3 d.N/A R= ft2 10.Ceiling Types (1555.0 sqft.) Insulation Area 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1555.00 ft2 6. Conditioned floor area above grade(ft2) 1555 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(104.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 311 a. U-Factor: Dbl,U=0.54 55.00 ft2 SHGC: SHGC=0.31 b. U-Factor: Dbl, U=0.56 33.33 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 24.0 SEER:15.50 c. U-Factor: Dbl,U=0.56 16.00 ft2 SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 24.0 HSPF:9.00 SHGC: Area Weighted Average Overhang Depth: 1.319 ft. Area Weighted Average SHGC: 0.309 14.Hot water systems 8. Floor Types (1555.0 sqft.) - Insulation Area a.Electric Cap:40 gallonsEF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1555.00 ft2 b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.067 Total Proposed Modified Loads: 50.56 PASS Total Baseline Loads: 50.93 I hereby certify that the plans and specifications covered by i Review of the plans and Q 'TI STET this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance + �aveGaI�GGt with the Florida Energy Code. +" PREPARED BY: Before construction is completed ... DATE: this building will be inspected for compliance with Section 553.908 I herebycertify that this building,as si ned, is in compliance Florida Statutes. fY 9� 9 P "� ---- .- with the Florida Energy Code. MAY 0 3 2018 cod OWNER/AGENT: BUILDING OFFICI DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.040 Qn for whole house. 5/1/2018 8:18 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 4 c I FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 1551131 sf ADS Carrier Builder Name: Lennar Homes Street: 3107 Kresterbrooke Lane Permit office: City of Zephyrhills City,State,Zip: FL, Permit Number: Owner: Lennar Homes Jurisdiction: 611600 Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(1497.3 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1176.00 ft2 b.Frame-Wood,Adjacent R=11.0 321.33 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 3 d.N/A R= ft2 10.Ceiling Types (1555.0 sqft.) Insulation Area 5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1555.00 ft2 6. Conditioned floor area above grade(ft2) 1555 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(104.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 311 a. U-Factor: Dbl,U=0.54 55.00 ft2 SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.56 33.33 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a.Central Unit 24.0 SEER:15.50 c. U-Factor: Dbl,U=0.56 16.00 ft2 SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 24.0 HSPF:9.00 SHGC: Area Weighted Average Overhang Depth: 1.319 ft. Area Weighted Average SHGC: 0.309 14.Hot water systems 8. Floor Types (1555.0 sqft.) Insulation Area a.Electric Cap:40 gallons a.a.Slab-On-Grade Edge Insulation R=0.0 1555.00 ft2 b. Conservation features b.N/A R= ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.067 Total Proposed Modified Loads: 50.56 PASS Total Baseline Loads: 50.93 1 hereby certify that the plans and specifications covered by Review of the plans and 'fk1E$?�] (?�" T� this calculation are in compliance with the Florida Energy specifications covered by this =<< Code. calculation indicates compliance with the Florida Energy Code. �. rirrr°+.i?% ••,; = +�`'«{O Dave Aup cG� . - , PREPARED BY: Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 I hereby certify that this building,as signed, is in compliance Florida Statutes.with the Florida Energy Code. MAY .0 3 2018 W>✓ OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.040 Qn for whole house. 5/1/2018 8:18 AM EnergyGaugeO USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 4 • FORM R405-2017 PROJECT Title: 1551131 sf ADS Carrier Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1555 Lot# Owner Name: Lennar Homes Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: Lennar Homes Rotate Angle: 45 Street: Permit Office: Cross Ventilation: County: Pasco Jurisdiction: Whole House Fan: City,State,Zip: Family Type: Single-family FL, New/Existing: New(From Plans) Comment: FBC 2017 CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Tampa FL_TAMPA INTERNATI 39 91 70 75 645.5 54 Medium BLOCKS Number Name Area Volume 1 Block1 1555 12440 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1555 12440 Yes 4 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio Main 134 ft 0 1555 ft2 -__ 0.3 0 0.7 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1684 ft2 0 ft2 Medium 0.85 No 0.9 ' No 0 22.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 1555 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) Main 30 Blown 1555 ft2 0.11 Wood 5/1/2018 8:18 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 4 i FORM R405-2017 WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below# Ornt In Wall Type 1 N=>NE Exterior Concrete Block-Int Insul Main 4.0999 20 8 160.0 ft2 0 0.600000 0 2 E=>SE Exterior Concrete Block-Int Insul Main 4.0999 54 8 432.0 ft2 0 0.600000 0 3 S=>SW Exterior Concrete Block-Int Insul Main 4.0999 34 8 272.0 ft2 0 0.600000 0 4 W=>NW Exterior Concrete Block-Int Insul Main 4.0999 33 8 264.0 ft2 0 0.600000 0 5 N=>NE Garage Frame-Wood Main 11 19 8 8 157.3 ft2 0 0.01 0 6 W=>NW Garage Frame-Wood Main 11 20 6 8 164.0 ft2 0 0.01 0 7 S=>SW Exterior Concrete Block-Int Insul Main 4.0999 6 8 48.0 ft2 0 0.600000 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N=>NE Insulated Main None .2 3 6 8 20 ft2 2 N=>NE Wood Main None .4 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered orientation => changed to Worst Case. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N=>NE 1 Metal Low-E Double Yes 0.56 0.28 N 16.0 ft2 1 ft 0 in 4 ft 0 in Drapes/blinds None 2 E=>SE 2 Metal Low-E Double Yes 0.54 0.31 N 16.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds None 3 S=>SW 3 Metal Low-E Double Yes 0.54 0.31 N 16.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds None 4 S=>SW 7 Metal Low-E Double Yes 0.56 0.32 N 33.3 ft2 2 ft 0 in 0 ft 4 in Drapes/blinds None 5 S=>SW 3 Metal Low-E Double Yes 0.54 0.31 N 23.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 408 ft2 408 ft2 40 ft 8 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1451.3 ' 79.68 149.84 .2669 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ None HSPF:9 24 kBtu/hr 1 sys#1 5/1/2018 8:18 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 4 r FORM R405-2017 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15.5 24 kBtu/hr 720 cfm 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 40 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ftz DUCTS —Supply— —Return— Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 311 ft2 Main 77.8 ftZ Proposed Qn Main —cfm 62.2 cfm 0.04 0.60 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: CoolingJan Feb Mar [ A r Ma rl Jun Jul X Au Se Oct [ ]Nov Dec Heatin Jan Feb ki Mar [ APr May Jun Jul AujXj SeP Oct [X]Nov X Dec Ventin Jan Feb Mar [X Apr [ May Jun Jul [ Aug Se [X Oct [X]Nov [ Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 '12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 - 68 68 68 68 68 68 68 68 66 66 i 5/1/2018 8:18 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 4 FORM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the EnergyPerformance Index, the more efficient the home. FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1176.00 ft2 b.Frame-Wood,Adjacent R=11.0 321.33 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 3 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types Insulation Area a.Under Attic(Vented) R=30.0 1555.00 ft2 6. Conditioned floor area(ft2) 1555 b.N/A R= ft2 7. Windows** Description Area c' R= ft2 a. U-Factor: Dbl,U=0.54 55.00 ft2 11.Ducts R ft2 a.Sup:Attic,Ret:Main,AH:Main 6 311 SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.56 33.33 ft2 SHGC: SHGC=0.32 12.Cooling systems kBtu/hr Efficiency c. U-Factor: Dbl,U=0.56 16.00 ft2 a.Central Unit 24.0 SEER:15.50 SHGC: SHGC=0.28 d. U-Factor. N/A ft2 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 24.0 HSPF:9.00 Area Weighted Average Overhang Depth: 1.319 ft. Area Weighted Average SHGC: 0.309 8. Floor Types Insulation Area 14.Hot water systems a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 1555.00 ft2EF:0.95 b.N/A R= ft2 c.N/A R= ft2 b. Conservation features None 15.Credits Pstat 1 certify that this home has complied with the Florida Energy Efficiency Code for Buildingti :Sr Construction through the above energy saving features which will be installed (or exceeded) tia : °.4?Ao in this home before final inspection. Otherwise, a new EPL Display Card will be completed �iQ',;,;''% �_'=4,�• 'f� based on installed Code compliant feat res. W - ��as• 1ti /�, Builder Signature: Date: 05/02/18 ?+ Address of New Home: 3107 Kresterbrooke Lane City/FL Zip: ZeFhyrhills,FL 33540 4 *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 5/1/2018 8:19 AM EnergyGauge®USA-FlaRes2017 -Section R405.4.1 Compliant Software Page 1 of 1 Buildin Anal SIS Job: 1551B1 sf ADS Carrier g Y Date: 5/1/2018 Entire House By: Dave BAYONET PLUMBING COOLING HEATING Project Information For: Lennar Homes Design Conditions Location: Indoor: Heating Cooling Tampa International AP, FL, US Indoor temperature(OF) 70 75 Elevation: 10 ft Design TD (OF) 39 16 Latitude: 28°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 34.7 54.7 Dry bulb(OF) 31 91 Infiltration: Daily range(OF) - 14 ( L ) Method Simplified Wet bulb(OF) - 77 Construction quality Semi-tight Wind speed (mph) 15.0 7.5 Fireplaces 0 • Component Btuh/ftZ Btuh % of load Walls 5.6 6121 28.1 Duds Glazing 30.2 3154 14.5 wall nfiltration Doors 23.5 480 2.2 Ceilings 1.3 1950 8.9 Floors 3.7 5815 26.7 Infiltration 1.9 2372 10.9 Ducts 1901 8.7 Floors Humidification 0 0 Glazing Ventilation 0 0 Doors Adjustments Q Ceilings Total 21794 100.0 Component Btuh/ftZ Btuh % of load Walls 2.8 3045 16.1 Walls Glazing 59.1 6179 32.6 Internal Gains Doors 18.4 376 2.0 Ceilings 1.7 2697 14.2 Floors 0 0 0 Infiltration 0.4 531 2.8 Ducts Ducts 2200 11.6 Ventilation 0 0 Internal gains 3923 20.7 Glazing In Blower 0 0 Adjustments 0 Ceilings Total 18950 100.0 Other Latent Cooling Load=2642 Btuh Overall U-value= 0.103 Btuh/ftZ-°F Data entries checked. -� =i s ghtc ft- 2018-May-01 08:13:44 ^�^•� Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 ..equipment\1551 sf ADS template 2ton Carrier.rup Calc=MJ8 Front Door faces:SE Project Summary Job: 1551B1 sf ADS Carrier ry Date: 611/2018 Entire House By: Dave BAYONET PLUMBING COOLING HEATING Project • • I For: Lennar Homes Notes: D - •-in Information Weather: Tampa International AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 31 OF Outside db 91 OF Inside db 70 OF Inside db 75 OF Design TD 39 OF Design TD 16 OF Daily range L Relative humidity 50 % Moisture difference 55 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 19893 Btuh Structure 16750 Btuh Ducts 1901 Btuh Ducts 2200 Btuh Central vent(0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh none (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 21794 Btuh Use manufacturer's data Rate/swing multiplier 1.00 Infiltration Equipment sensible load 18950 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 2252 Btuh Ducts 390 Btuh Central vent(0 cfm) 0 Btuh Heating Coolingg (none) lArea(ft2) 1555 1555 Equipment latent load 2642 Btuh Volume(ft') 12700 12700 Air changes/hour 0.26 0.14 Equipment Total Load (Sen+Lat) 21592 Btuh Equiv.AVF(cfm) 55 30 Req. total capacity at 0.85 SHR 1.9 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade Trade Model 25HBC524AO0300 Cond 25HBC524AO0300 AHRI ref 9154943 Coil FB4CNP025L AHRI ref 9154943 Efficiency 9 HSPF Efficiency 12.5 EER, 15.5 SEER Heating input Sensible cooling 20400 Btuh Heating output 24000 Btuh @ 47'F Latent cooling 3600 Btuh Temperature rise 27 OF Total cooling 24000 Btuh Actual air flow 800 cfm Actual air flow 800 cfm Air flow factor 0.037 cfm/Btuh Air flow factor 0.042 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.88 Capacity balance point= 30 OF Backup: n/a n/a Input= 0 kW, Output= 0 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -Fid- wrightsoft- 2018-May-01 08:13:45 Right-Suite®Universal 2018 18.0.16 RSU05714 Pagel ACCk ...equipment\1551 sf ADS template 2ton Carrierrup Calc=MJ8 Front Door faces:SE Manual S Compliance Report Job: 1551B1 sf ADS Carrier Date: 511l2018 Entire House, By: Dave BAYONET PLUMBING COOLING HEATING Project Information For: Lennar Homes Cooling Equipment Design Conditions Outdoor design DB: 91.3°F Sensible gain: 18950 Btuh Entering coil DB: 75.7°F Outdoor design WB: 77.3°F Latent gain: 2642 Btuh Entering coil WB: 62.8°F Indoor design DB: 75.0°F Total gain: 21592 Btuh Indoor RH: 50% Estimated airflow: 800 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: SpIitASHP Manufacturer: Carrier Model: 25HBC524A00300+FB4CNP025L Actual airflow: 800 cfm Sensible capacity: 20400 Btuh 108% of load Latent capacity: 3600 Btuh 136% of load Total capacity: 24000 Btuh 111% of load SHR: 85% Heating Equipment Design Conditions Outdoor design DB: 30.8°F Heat loss: 21794 Btuh Entering coil DB: 69.6°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: SpIitASHP Manufacturer: Carrier Model: 25HBC524A00300+FB4CNP025L Actual airflow: 800 cfm Output capacity: 18304 Btuh 84% of load Capacity balance: 30 OF Supplemental heat required: 3490 Btuh Economic balance: -99 OF Backup equipment type: Elec strip Manufacturer: n/a Model: n/a+n/a Actual airflow: 800 cfm Output capacity: 0 kW 0% of load Temp. rise: 0 OF Meets all requirements of ACCA Manual S. wrightsoft® 2018-May-01 08:13:45 ACCK Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 ...equipment\1551 sf ADS template 2ton Carrier.rup Calc=MJ8 Front Door faces:SE L I --cff— ................ LL Ff EL 7423 iv FF EL A 6 98 \T4.rA/ L J. .......... A F V —7- .L P EL EL 5-0 FFF A 799 126 NKA:o� r- -7 PNIASE I MEL. 32- 1 FFEL 7D M 100 125 .4) I Ffa. 34 101 IW73Z L A =A F T M .34 7L 1 FFEL -=A FFF E 102 123 VIM/ r—Al I FFEL WFF 0. A 1 4- 35 1 A I 33 t 13 i FFEL 6 L : " I: M 104 \72M/1121 A 'M A rFFE7L FFEL 37 \rim/ 72M 105 120 A \72A FFW. I 39 TIA I 40 106 FFEL J\ FrM.119 A-6 A Fr FFEL I 7100 1%. FF a A 1 W2 07 6A A > 118 \rim/ 8 10 FF EL A 109 LAJ rag, 4p . 117 11% j�l N FF: 0 71.1 A qo p A LLI 411 SCALE 7 ley-Hom AS NOTED L -f 7 and ksodates, Inc. 11E�'Gtlm i3 SP HIDDEN 1; 2006 KlkU-Y-HQR-N AND AS$OCUNTESS, 04C. DRAWN BY 5344 97,14 SIREET, ZEPHYRKILLS, i-LaRIDA 33542 SID :140fit-, (513) 758-040D . FAX (813) -782-497E CHECKED By ;lr-eAV.KfMU-:y-M0RN.CV44 CA U-MC10525 f%LC I Cl 1 Y OF ZEEPH YPHILI 5 .......... C PLOT PLAN SKETCH ONLY NOT A BOUNDARY SURVEY SEC. 24 TWP. 26 S, RNG. 21 E. LOT 116 BEARING BASIS: HIDDEN RIVER PHASE ONE B NORTH BOUNDARY OF SUBJECT PLAT BEING S 89*40'43" E PASCO COUNTY, FLORIDA. THIS SURVEY IS SUBJECT TO ANY FACTS THAT MAY BE DISCLOSED BY A FULL AND ACCURATE ON LOT AREA CALCULATIONS N TITLE SEARCH. ALSO SUBJECT TO SETBACKS, LOT FT. EASEMENTS AND RESTRICTIONS OF RECORD. LIVING AREA =-1-±Q 25�--SQ. FT.—SQ. FT. ENTRY = UNDERGROUND FOOTER, STEM WALL, AND GARAGE =----12-6—SQ. FT.--- 0 rn UNDERGROUND UTILITIES ARE NOT LOCATED OR COVERED LANAI =--.NJ—A --SQ. FT. Il SHOWN. PATIO 23 -SO. FT. DO NOT SCALE THIS'PRINT. DIMENSIONS AND CONC. DRIVE =--j*L---SQ. FT. iii NOTES TAKE PREFERENCE. A/C & CONC PAD =-A—SQ. FT. PRIVATE SIDEWALK =--VL—SQ. FT. DESCRIPTION NOT CONTAINING PLAT BOOK AND IMPERVIOUS PAGE INDICATES THAT PLAT IS IN =--2-520L--SQ. FT. PRELIMINARY STAGE AND IS SUBJECT TO SOD =--;tl-1-7—SO. FT. CHANGE AND/OR REVISION. OFF LOT AREA CALCULATIONS CERTAIN DATA SHOWN HEREON BASED ON RIGHT OF WAY FT. ENGINEERING PLANS PROVIDED BY CLIENT. DRIVE APRON FT. STRUCTURE TIES SHOWN HEREON DENOTES PUBLIC SIDEWALK =--.11-(L--SQ. FT. MEASUREMENT FROM FORM BOARDS/FOUNDATION SOD =-AQL--SQ. FT. TO PROPERTY LINE. TOTALS PRELIMINARY DRAWING: AREA 8594.07 SQ. FT. THIS PLAN IS FOR PERMITTING PURPOSES DRIVEWAY =--§.Q-2--SQ, FT. ONLY, NOT FOR CONSTRUCTION. VERIFY SIDEWALK =--�144—SQ. FT. LOT 107 ALL DIMENSIONS BEFORE ANY CONSTRUCTION. SOD FT. HIDDEN RIVER PHASE ONE A NOTES: (PLAT BOOK 74, PAGES 101-121) LEGEND: LOT GRADING TYPE = A PROPOSED DRAINAGE FLOW PROPOSED PAD ELEVATION = N/A (00.00) = PROPOSED GRADE FRONT SETBACK = 20' E-00.00 = EXISTING GRADE SIDE SETBACK = 10' 10' DRAINAGE/UTILITY EASEMENT REAR SETBACK 10' PRM(P) -(71.25') LOT 108 (TYP) HIDDEN RIVER PHASE ONE A (PLAT BOOK 74, PAGES 101-121 \A LOT 116 LOT 117 (71.50')- Jm. O AIG 0 Al 01+ PLAT BOUNDARY -10 \0. PLAT BOUNDARY (710.74-) LOT 115 A 1;dl 'A A (70.99' o) \IA N-5b , :p -'?� ?� 20�6" ( d ��R��,\93 1 PROPOSED: DESCRIPTION LOWEST FLOOR ELEVATIONS: LIVING AREA: 72.25' LOT 116, MAP OR PLAT ENTITLED "HIDDEN RIVER PHASE ONE 13", GARAGE AREA: N/A AS RECORDED IN PLAT BOOK ---, PAGES --- THROUGH ELEVATIONS REFERENCED TO OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. NATIONAL GEODETIC VERTICAL I CURVE I RADIUS I ARC I CHORD BEARING I DELTA DATUM OF 1929. MEAN SEA 248 59.37- 1 59.29- '45-25" W 1 09-4X06- LEVEL= 00.00 FT. 350.00' S 59 240.00' 40.71- 1 40.66- 1 N 59'45'25" E 1 09*43'06" 1 APPARENT FLOOD HAZARD ZONE: "X" COMMUNITY PANEL NO. 120230 0460 D EFFECTIVE DATE: 9/30/1992 LEGEND: (C)= CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, %= CENTERLINE, A/C= AIR CONDITIONER, B/C= BACK OF CURB, C/S= ICONCRETE SLAB, CH= CHORD, CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= COVERED, E/P= EDGE OF PAVEMENT, ESM'T= EASEMENT F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE, FIR= FOUND IRON ROD, FNScD= FOUND NAIL & DISK, FPP= FOUND PINCHED PIPE, LFE= LOWEST FLOOR ELEVATION, MAS,= MASONRY, OR= OFFICIAL RECORD BOOK, PB= PLAT BOOK, PCP= PERMANENT CONTROL POINT, PRM= PERMANENT REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & CAP No. 4493, SN&D= SET NAIL & DISK, TBM= TEMPORARY BENCHMARK U/P= UTILITY POLE, W/F= WOOD FENCE, (R) = RADIAL JOHN R.BEACH&ASSOCIATES,INC. Drawn By: SMS Square Feet: 7636.81 t LENNAR HOMES SURVEYORS AND MAPPERS Checked By: 911 WEST ST. PETERSBURG DRIVE ONE OLDSMAR, FLORIDA 34677 JRB WAY (813) 854-1276 FAX (813) 855-8370 Scale: 1.=30 c)44 t7j�g NOT VALID WITHOUT THE SIGNATURE AND Date of Survey: THE ORIGINAL RAISED SEAL OF A FLORIDA PLOT PLAN 04/18/2018 RTM J N BEACH DATE LICENSED SURVEYOR AND MAPPER ORIDA R . LAND SURVEYOR No. 2984 LB#4493 Revisions: Lennar Homes-3107 Kresterbrooke Ln-2,005 sq ft Column SQ. FEET PRICE MAIN OR LIVING: 2,005 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 225,863.25 FEE SHEET $ 1,170.00 ADDRESS $ 30.00 DRIVEWAY $ 45.00 BUILDING: $ 1,268.40 ELECTRICAL: $ 263.25 PLUMBING: $ 175.50 MECHANICAL: $ 122.85 SUB-TOTAL $ 1,830.00 TOTAL $ 1,830.00 SEWER: $ 2,090.00 WATER: $ 1,010.00 IRRIGATION: $ - TOTAL: $ 3,100.00 WATER METER: $ 473.78 IRRIGATION METER FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 5,957.13 PARK IMPACT FEES $ 769.56 SIF'S: $ 7,128.00 100.0% $ 7,128.00 1.0% $ 71.28 TOTAL: $ 7,199.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 17,557.97 Jacqueline Boges From: City of Zephyrhills Support<support@zephyrhillsfl.zendesk.com> Sent: Friday, June 29, 2018 12:55 PM To: Jacqueline Boges Subject: [Request received]3107 Kresterbrooke Lane by#19803 ##- Please type your reply above this line -## Hello Jacqueline Boges, We are working to resolve your request promptly and will keep you updated. One of our Support Analysts will keep you updated on the progress of your request. Best Regards, FATHOM Support Team TO ADD ADDITIONAL COMMENTS, reply to this email or click the link below: https://zephyrhilisfl.zendesk.com/hc/requests/223485 ....................................................................................................................................................................................................................................................................................................................................................................................... Jacqueline Boges �- Jun 29, 9:55 AM MST full water 3107 kresterbrooke lane by#19803 water , sewer water meter This email is a service from City of Zephyrhills Support . 1 City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: Lu .Aa-r— 04� Date Received: L�v , I Site: t Permit Type: �, d 5— Approved w/no comments:El Approved w/the below comments: Denied w/the below comments: ❑ This comment shneet. hall be kept with the permit and/or plans. Kalvin SVAezer—Plans Examiner Date Contractor and/or Homeowner (Required when comments are present) Jacqueline Boges From: Nichole Spence(City of Zephyrhills Support)<support@zephyrhillsfl.zendesk.com> Sent: Saturday, July 14, 2018 12:02 PM To: Jacqueline Boges Subject: [FATHOM] Re: 3107 Kresterbrooke Lane by#19803 ##- Please type your reply above this line -## Your request (#223485) has been updated. REPLY TO THIS EMAIL or click the link below: https://zephyrhillsfl.zendesk.com/hc/requests/223485 .................................................................................................................................................................................................................................................................................................................................................................................... Ii Nichole Spence (City of Zephyrhills Support ) Jul 14, 9:01 AM MST Account# 2996799 has been created, service order to follow once mapping has been completed. Best Regards, Nichole I FATHOM Support ................................................................................ ........................................................ .............................. .................... .._................................................................................................ .......... ........................................ .... Jacqueline Boges L�_ Jun 29, 9:55 AM MST full water 3107 kresterbrooke lane by#19803 water , sewer water meter This email is a service from City of Zephyrhills Support . 1 n PASCO COUNTY DEVELOPMENT SERVICES PAS"C ", 8731 Citizens Rrive Date;8/7/2018 COUNTY FLORIDA -New Port Richey,FL 34654 -72 - 7-84Z-2411 - -- - — - — -- Orrrt Srncrs.Vii3r.�Nr1'incrs.✓-- - -- - - - -- — '�* 1"N'®T A PERMIT Receipt#: 1782493, FEE DESCRIPTION ACCOUNT CODE UNITS' INVOICE# FEE AMOUNT PAID. RECEIPT# DATE Impact Fee Residential Solid 24503100-329010 25.50 1372060 $25.50 $25.50 1782493 817/18 Waste Single Family 3107 KRESTERBROOKE LANE, TOTALS: $25.60 $25.50 'Receipt# Paid By Check# CC Auth# Cashier ID Workstation Receipt Dafe Amt Paid 178249.3 Check. 01029755 '554 8CCCP58W 08/07/2018 $25.50 Total Payments:, $26.50 Pavor Address Phone LENNAR HOMES LLC ,Comments: 3107 KRESTERBROOKE LANE While you will be paying your bill with Pasco County Development Services,the full amount of,the credit card-or a-check fees,NOT shown above,Is collected by First Billing payment services. 02895856' Lennar Homes,LLC JPMdrgan Chase Bank N.A. STUB CHECK NO. 1029755 WYOICE 900000.1010.114 ' 1 of I DATE 08/02/18 I' CO.#. NUMBER DATE PAYMENTADYICE GROSS DISCOUNT NET 15174 15174720116.401435 072418 15174720116 401435 $25.50 $0.00 ,` $25,50 1 Pasco County BO C Little Road 1971597 /' Pori Richey FL 335534000 $25.50 $0.00 $25.50 MyReports/reports//PASCOPROD/PASCO/ReceiptPOS_V6:rpt 8%7/2018 Page 1 of 1 I 5335 - 8TH STREET (813)780-0020 CERTIFICATE OF OCCUPANCY I Address: 3107 KRESTERBROOKE LANE Owner: LENNAR HOMES LLC j ZEPHYRHILLS, FL. 4600 W CYPRESS ST STE 200 Subdiv: HIDDEN RIVER TAMPA FL 33607-4099 Parcel: 24-26-21-0100-00000-1160 Work Type: 101-NEW CONST/SFR Construction Type: NOT APPLICABLE ❑ Sprinklers Use Classification: NOT APPLICABLE Permit Number: 19803 Date: 10/16/2018 ISSUED BUILDI OFFICIAL WATER MUST BE CHANGED OVER WITHIN 10 DAYS OF ISSUANCE GARBAGE DEPOSIT MUST BE APPLIED FOR PRIOR TO ISSUANCE