Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
18-19804
CITY OF ZEPHYRHILLS 5335-8TH STREET -(813)780-n020 _ 19804 BUILDING PERMIT SINGL�FAMILY RESIDENTIAL PERMIT INFORMATION LOCATION INFORMATION Permit#:19804 Issued: 6/25/2018 Address: 3112 KRESTERBROOKE LANE Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 378,391.35 Total Fees: 18,705.47 Subdivision: HIDDEN RIVER Amount Paid: 18,705.47 Date Paid: 6/25/2018 Parcel Number: 24-26-21-0100-00000-0760 CONTRACTOR INFORMATION OWNER INFORMATION Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC Addr: 4600 W. CYPRESS ST STE 200 Address: 4600 W CYPRESS ST STE 200 TAMPA, FL. 33607 TAMPA FL 33607-4099 Phone: (813)574-5743 Lic: Phone: 813-574-5700 Work Desc: CONSTRUCT SINGLE FAMILY 3,359 SQ FT APPLICATION FEES BUILDING FEE 2,048.69 ELECTRICAL FEE 435.38 PLUMBING FEE 290.25 MECHANICAL FEE 203.18 SEWER CONNECTION RESIDEW 2,090.00 WATER METER RES 3/4" 473.78 WATER CONNECTION RESIDENT 1,010.00 PARK FEES SF 769.56 FIRE IMPACT FEE 273.00 POLICE IMPACT FEE 254.00 PUBLIC SAFETY 5% 26.35 SCHOOL IMPACT FEE NEW 7,128.00 SCHOOL-SFR NEW 1% 71.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32 Ins ect' ns Required FOOTER 2ND ROUGH PLUMB Misc INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing, consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. T, &__ CO RACTORS SIGNATURE PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER L-ennar Homes-3112 Kresterbrooke Lane-3,359 sq ft Column ts SQ. FEET PRICE MAIN OR LIVING: 3,359 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 378,391.35 FEE SHEET $ 1,935.00 ADDRESS $ 30.00 DRIVEWAY $ 45.00 BUILDING: $ 2,048.70 ELECTRICAL: $ 435.38 PLUMBING: $ 290.25 MECHANICAL: $ 203.18 SUB-TOTAL $ 2,977.50 TOTAL $ 2,977.50 SEWER: $ 2,090.00 WATER: $ 1,010.00 IRRIGATION: $ - TOTAL: $ 3,100.00 WATER METER: $ 473.78 IRRIGATION METER FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 7,104.63 PARK IMPACT FEES $ 769.56 SIF'S: $ 7,128.00 100.0% $ 7,128.00 1.0% $ 71.28 TOTAL: $ 7,199.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 18,705.47 City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: Leh ortir "' s r Date Received: ",- Site: 4, Permit Type: 1 ���/4 Approved w/no comments:El Approved w/the below comments: Denied w/the below comments: ❑ This comment sheet shall be kept with the permit and/or plans. ti Kalvir6w�ez , —Plans Examiner Date Contractor and/or Homeowner (Required when comments are present) Jacqueline Boges From: City of Zephyrhills Support<support@zephyrhillsfl.zendesk.com> Sent: Friday, June 29, 2018 12:19 PM To: Jacqueline Boges Subject: [Request received] 3112 Kresterbrooke lane by#19804 ##- Please type your reply above this line -## Hello Jacqueline Boges, We are working to resolve your request promptly and will keep you updated. One of our Support Analysts will keep you updated on the progress of your request. Best Regards, FATHOM Support Team TO ADD ADDITIONAL COMMENTS, reply to this email or click the link below: https://zephyrhillsfl.zendesk.com/hc/requests/223466 ....................................................................................................................................................................................................................................................................................................................................................................................... Jacqueline Boges Jun 29, 9:18 AM MST full service 3112 Kresterbrooke Lane by#19804 water, sewer, water meter This email is a service from City of Zephyrhills Support . 1 � 2018103055l�Ifll lull hill Illli 11111111111111IIII - cpt:1966851 Rec: 10.00 S: 0.00 IT: 0.00 06/19/2018 C. F. , Dpty Clerk �pULp S.O'NEIL,Ph.D.PASCO CLERK &�CyOMP+TrR�OLLER 6OR Br, 16743 Pr 'V08 OR Br, ' Permit No. Parcel ID No 24-26-21-0100-00000-0760 NOTICE OF COMMENCEMENT State of Florida County of Pasco THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 713,Florida Statutes, the following information is provided in this Notice of Commencement: 1. Description of Property: Legal HIDDEN RIVER PHASE ONE B PB 76 PG 77 LOT 76 ' street Address: 3112 Kresterbrooke Lane Zephryhills FL 33541 2. General Description of improvement single Family Residence/Pool!Screen Enclosure/Fence 3. Owner Information: Lennar Homes,LLC. Name 4600 W Cypress St. Ste 200 Tampa FL. 33607 Address City State Interest in Property: Name of Fee Simple Titleholder:- N/A (If other than owner) Address City State 4. Contractor: Lennar Homes, LLC Name 4600 W Cypress St, Ste 200 Tampa, FL, 33607 Address City State Contractor's Telephone No.: 813.574.5700 5. surety: NIA Name Address City State Amount of Bond: $ Telephone No.: 6. Lender: N/A Name Address City State Lender's Telephone No.: 7. Persons within the State of.Florida designated by the owner upon whom notices or other documents may be served as provided by Section-713.13(1)(a)(7),Florida Statutes: Lennar Homes, LLC Name 4600 W Cypress St, Ste200 Tampa FL, 33607 Address City State Telephone Number of Designated'Person: 813.574,5700 1 8. in addition to himself,the owner designates N/A of to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statutes.. Telephone Number of Person or Entity Designated by Owner: 9. Expiration date of Notice of Commencement is one year from the date of recording unless a different date is specified: WARNING TO OWNER: ANY PAYMENTS MADE BY THE-OWNER AFTER THE.EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER .PAYMENTS UNDER CHAPTER.713, PART 1, SECTION 713.13, FLORIDA-STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY: A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. STATE OF FLORIDA COUNTY OF PINELLAS signature of Owner or Owner's Authorized Officer/Director/Partner/Manager Vice President Signatory's Title/Office The foregoing instrument was acknowledged before me this 30 day of March ,by Steve Robert Smith as Vice President (type of authority,e.g.,officer,trustee,attorney in fact)for Lennar Homes LLC (name of party o alf o instrument was executed). Personally Known R OR Produced Identification❑ Notary Si ature Type of Identification Produced Name(Print) SSa olleran Verification pursuant to Section 92.525,Florida Statutes. Under penalties of.perjury,I declare that i have read the foregoing and that the facts stated in it are true to the best of my knowledge and belief. ASAMAOLUPAN Signature of Natural Person Signing Above COMMI1e100 FF 985637 ' ltes June 8,2020 wpdata/bcs/bcs form; ". '`.�ndilthru7ret!FdnlM4ana100,1{570.io . FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regdla-tion - Residential Performance Method Project Name: 2889A1 sf ADS Carrier Builder Name: Lennar Homes Street: 3112 Kresterbrooke Lane Permit Office: 1City of Z�hyrhills City,State,Zip: FL, Permit Number: f 7,Owner: Lennar Homes Jurisdiction: (� Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(2754.2 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1308.70 ftz b.Frame-Wood,Exterior R=11.0 1114.00 ft 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 331.50 ft2 4. Number of Bedrooms 5 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (2307.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 2167.00 ft2 6. Conditioned floor area above grade(ftz) 2896 b.Knee Wall(Vented) R=30.0 140.00 ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(193.3 sqft.) Description Area a.Sup:Attic,Ret:1st Floor,AH:1st Floor 6 358.6 a. U-Factor: Dbl,U=0.54 96.00 ft2 b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 221 SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.56 64.00 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.28 a.Central Unit 24.0 SEER:15.50 b.Central Unit 18.0 SEER:15.00 c. U-Factor: Dbl,U=0.56 33.33 ft2 SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 24.0 HSPF:9.00 SHGC: b.Electric Heat Pump 17.7 HSPF:8.50 Area Weighted Average Overhang Depth: 1.172 ft. Area Weighted Average SHGC: 0.302 14.Hot water systems 8. Floor Types (2902.0 sqft.) Insulation Area a.Electric Cap:40 gallons EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1793.00 ft2 b. Conservation features b.Floor Over Other Space R=0.0 672.00 ft2 None c.other(see details) R= 437.00 ft2 15.Credits Pstat Glass/Floor Area: 0.067 Total Proposed Modified Loads: 85.94 PASS Total Baseline Loads: 85.84 I hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: Dave Autich Before construction is completed DATE: this building will be inspected for f . compliance with Section 553.908 I hereby certify that this building,as designed, is in compliance Florida Statutes. with the Florida Energy Code. MAY 0 3 2016 OWNER/AGENT: BUILDING OFFICI DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 6.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.030 Qn for whole house. 5/1/2018 1:11 PM EnergyGaugeO USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-20* FLORIDA ENERGY EFFICIENCY;CODE FOR, BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 2889A1 sf ADS Carrier Buildet-Name: Lennar Homes Street: 3112 Kresterbrooke Lane Permit office: City of Zephyrhills City,State,Zip: FL, Permit Number: Owner: Lennar Homes Jurisdiction: 611600 Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(2754.2 sgft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1308.70 ft2 b:Frame-Wood,Exterior R=11.0 1114.00 ft2 3. Number of units,if multiple family 1 C.Frame-Wood,Adjacent R=11.0 331.50 ft2 4. Number of Bedrooms 5 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (2307.0 sgft.) Insulation Area a.Under Attic(Vented) R=30.0 2167.00 ft2 6. Conditioned floor area above grade(ft2) 2896 b.Knee Wall(Vented) R=30.0 140.00 ft2 Conditioned floor area below grade(ft2) 0 • c.N/A R= ft2 11.Ducts R ft2 7. Windows(193.3 sgft.) Description Area a.Sup:Attic,Ret:1st Floor,AH:1st Floor 6 358.6 a. U-Factor: Dbl,U=0.54 96.00 ft2 b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 221 SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.56 64.00 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.28 a.Central Unit 24.0 SEER:15.50 b.Central Unit 18.0 SEER:15.00 c. U-Factor: Dbl,U=0.56 33.33 ft2 SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency d. U.-Factor. N/A ft2 a.Electric Heat Pump 24.0 HSPF:9.00 SHGC: b.Electric Heat Pump 17.7 HSPF:8.50 Area Weighted Average Overhang Depth: 1.172 ft. Area Weighted Average SHGC: 0.302 14.Hot water systems 8. Floor Types (2902.0 sgft.) Insulation Area a.Electric Cap:40 gallonsEF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1793.00 ft2 b. Conservation features b.Floor Over Other Space R=0.0 672.00 ft2 None c.other(see details) R= 437.00 ft2 15.Credits Pstat Total Proposed Modified Loads: 85.94 Glass/Floor Area: 0.067 PASS Total Baseline Loads: 85.84 I hereby certify that the plans and specifications covered by Review of the plans andT_ :5 . this calculation.are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance ' 'r„ �4 \ 'Dave lol>'tGl� with the Florida Energy Code. ' PREPARED BY: Before construction is completed - DATE: this building will be inspected for compliance with Section 553.908 hereby certify that this building as g p designed, is in compliance Florida Statutes. !, _ with the Florida Energy Code. rCOZj.y MAY 0 3 2018 OWNER/AGENT: BUILDING OFFI IAL• DATE: 41,1 DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 6.00 ACH50(R402.4.1.2). Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.030 Qn for whole house. 5/1/2018 1:11 PM EnergyGaugeO USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5 i ' I FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: 2889A1 sf ADS Carrier Builder Name: Lennar Homes Street: 3112 Kresterbrooke Lane Permit office: City of Zephyrhills City,State,Zip: FL, Permit Number: Owner: Lennar Homes Jurisdiction: 611600 Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(2754.2 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1308.70 ft2 b.Frame-Wood,Exterior R=11.0 1114.00 ft2 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 331.50 ft2 4. Number of Bedrooms 5 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types (2307.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 2167.00 ft2 6. Conditioned floor area above grade(ft2) 2896 b.Knee Wall(Vented) R=30.0 140.00 ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(193.3 sqft.) Description Area a.Sup:Attic,Ret:1st Floor,AH:1st Floor 6 358.6 a. U-Factor: Dbl,U=0.54 96.00 ft2 b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 221 SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.56 64.00 ft2 12.Cooling systems kBtulhr Efficiency SHGC: SHGC=0.28 a.Central Unit 24.0 SEER:15.50 b.Central Unit 18.0 SEER:15.00 c. U-Factor: Dbl,U=0.56 33.33 ft2 SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 24.0 HSPF:9.00 SHGC: b.Electric Heat Pump 17.7 HSPF:8.50 Area Weighted Average Overhang Depth: 1.172 ft. Area Weighted Average SHGC: 0.302 14.Hot water systems ft.) Insulation Area a.Electric Cap:40 gallons 8. Floor Types (2902.0 sqft.) EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1793.00 ft2 b. Conservation features b.Floor Over Other Space R=0.0 672.00 ft2 None c.other(see details) R= 437.00 ft2 15.Credits Pstat Glass/Floor Area: 0.067 Total Proposed Modified Loads: 85.94 PASS Total Baseline Loads: 85.84 I hereby certify that the plans and specifications covered by Review of the plans and a�. kl>✓.ST ?�, r'== this calculation are in compliance with the Florida Energy specifications covered;by this Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: Dave Aupich Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 hereby certify that this buildin9,as desi ned, is in compliance Florida Statutes. with the Florida Energy Code. gMAY 0 3 1 c0 OWNER/AGENT: ZO8. BUILDING OFFI IAL: DATE: DATE: - - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 6.00 ACH50(R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house. 5/1/2018 1:11 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5 • 1 I FORM R405-2017 i PROJECT Title: 2889A1 sf ADS Carrier Bedrooms: 5 Address Type: Street Address Building Type: User Conditioned Area: 2896 _ Lot# Owner Name: Lennar Homes Total Stories: 2 Block/Subdivision: #of Units: 1 Worst Case: Yes PlatBook: Builder Name: Lennar Homes Rotate Angle: 45 Street: Permit Office: Cross Ventilation: County: Pasco Jurisdiction: Whole House Fan: City,State,Zip: Family Type: Single-family FL, New/Existing: New(From Plans) Comment: FBC 2017 CLIMATE Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Tampa FL_TAMPA_INTERNATI 39 91 70 75 645.5 54 Medium BLOCKS Number Name Area Volume 1 Blockl 1793 15419.8 2 Block2 1103 8824 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 1st Floor 1793 15419.8 Yes 2 1 1 Yes Yes Yes 2 2nd Floor 1103 8824 No 4 4 1 Yes Yes . Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio 1st Floor 137 ft 0 1793 ft2 0.3 0 0.7 2 Floor over Garage 2nd Floor ____ ____ 437 ft2 11 0.15 0 0.85 3 Floor Over Other Space 2nd Floor 672 ft2 0 0 0 1 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg)' 1 Hip Composition shingles 2419 ft2 0 ft2 Medium 0.85 No 0.9 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 2233 ft2 N N 5/1/2018 1:11 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2017 CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) 2nd Floor 30 Blown 1103 ft2 0.11 Wood 2 Under Attic(Vented) 1st Floor 30 Blown 1064 ft' 0.11 Wood 3 Knee Wall(Vented) 2nd Floor 30 Batt 140 ft2 0.11 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below To Wall T-VPP 1 N=>NE Exterior Concrete Block-Int Insul 1st Floor 4.0999 19 8 8 164.7 ft' 0 0.600000 0 2 E=>SE Exterior Concrete Block-Int Insul 1st Floor 4.0999 58 8 8 502.7 ft2 0 0.600000 0 3 S=>SW Exterior Concrete Block-Int Insul 1st Floor 4.0999 34 8 8 294.7 ft2 0 0.600000 0 4 W=>NW Exterior Concrete Block-Int Insul 1 st Floor 4.0999 34 8 8 294.7 ft2 0 0.600000 0 5 N=>NE Garage Frame-Wood 1 st Floor 11 19 9 8 8 171.2 ft2 0 0.01 0 _ 6 W=>NW Garage Frame-Wood 1st Floor 11 18 6 8 8 160.3 ft2 0 0.01 0 7 N=>NE Exterior Frame-Wood 2nd Floor 11 40 8 320.0 ft2 0 0.600000 0 8 E=>SE Exterior Frame-Wood 2nd Floor 11 29 6 8 236.0 ft2 0 0.600000 0 9 S=>SW Exterior Frame-Wood 2nd Floor 11 40 8 320.0 ft' 0 0.600000 0 10 W=>NW Exterior Frame-Wood 2nd Floor 11 29 9 8 238.0 ft2 0 0 0.600000 0 11 S=>SW Exterior Concrete Block-Int Insul 1st Floor 4.0999 6 8 8 52.0 ft2 0 0.600000 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N=>NE Insulated 1st Floor None .2 3 6 8 20 ft2 2 W=>NW Wood 1st Floor None .4 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered orientation(=>)changed to Worst Case. Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N=>NE 1 Metal Low-E Double Yes 0.56 0.28 N 16.0 ft2 1 ft 0 in 13 ft 4 in None None 2 E=>SE 2 Metal Low-E Double Yes 0.54 0.31 N 16.0 ft2 1 ft 0 in 0 ft 10 in None None 3 S=>SW 3 Metal Low-E Double Yes 0.54 0.31 N 48.0 ft2 1 ft 0 in 0 ft 10 in None None 4 S=>SW 11 Metal Low-E Double i Yes 0.56 0.32 N 33.3 ft2 2 ft 0 in 0 ft 6 in None None 5 N=>NE 7 Metal Low-E Double Yes 0.56 0.28 N 32.0 ft2 1 ft 0 in 0 ft 4 in None None 6 E=>SE 8 Metal Low-E Double Yes 0.54 0.31 N 16.0 ft2 1 ft 0 in 0 ft 4 in None None 7 W=>NW 10 Metal Low•E Double Yes 0.54 0.31 N 16.0 ft2 1 ft 0 in 0 ft 4 in None None 8 N=>NE 7 Metal Low-E Double Yes 0.56 0.28 N 16.0 ft2 1 ft 0 in 3 ft 5 in Drapes/blinds None 5/1/2018 1:11 PM EnergyGaugeO USA-FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5 i FORM R405-2017 ' GARAGE # Floor Area Ceiling Area Exposed Wall Perirpeter Avg.Wall Height Exposed Wall Insulation 1 437 ft2 437 ft2 44 ft 8.6 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000319 2424.4 133.1 250.31 .2947 6 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ None HSPF:9 24 kBtu/hr 1 sys#1 2 Electric Heat Pump/ None HSPF:8.5 17.7 kBtu/hr 2 sys#2 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER:15.5 24 kBtu/hr 720 cfm 0.85 1 sys#1 2 Central Unit/ Split SEER: 15 18 kBtu/hr 540 cfm 0.85 2 sys#2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 40 gal 80 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS —Supply— —Return— Air CFM 25 CFM25 HVAC# # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 .358.6 ft 1st Floor 89.6 ft2 Proposed Qn 1st Floor —cfm 53.8 cfm 0.03 0.60 1 1 2 Attic i 6 221 ft2 2nd Floor 55 ft2 Proposed Qn 2nd Floor —cfm 33.1 cfm 0.03 0.60 2 2 5/1/2018 1:11 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2017 TEMPERATURES Programable Thermostat:Y Ceiling Fans: Cooling ]Jan Feb ]Mar A r r j Ma �Xj Jun �X Jul [X]Aug Se [ ]Oct Nov [ ]Dec Heatin [X]Jan f X�Feb EX]Mar E APr [ May Jun. [: Jul [ ]Aug �[ Sep [ ]Oct xNov [X]Dec Ventin [ ]Jan [ Feb [X]Mar [X A r [[[ Ma Jun [ Jul [ ]Au [ Se [X]Oct X Nov [ ]Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 5/1/2018 1:11 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5 FORM R405-2017. ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerformance Index, the more efficient the home. FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1308.70 ft2 b.Frame-Wood,Exterior R=11.0 1114.00 ft2 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 331.50 ft2 4. Number of Bedrooms 5 d.N/A R= ft2 5. Is this a worst case? Yes 10.Ceiling Types Insulation Area a.Under Attic(Vented) R=30.0 2167.00 ft2 6. Conditioned floor area(ft2) 2896 b.Knee Wall(Vented) R=30.0 140.00 ft2 7. Windows- Description Area c.N/A R= ft2 a. U-Factor. Dbl,U=0.54 96.00 ft2 11.Ducts R ft2 a.Sup:Attic,Ret:1st Floor,AH:1st Floor 6 358.6 SHGC: SHGC=0.31 b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 221 b. U-Factor: Dbl,U=0.56 64.00 ft2 SHGC: SHGC=0.28 12.Cooling systems kBtu/hr Efficiency c. U-Factor: Dbl,U=0.56 33.33 ft2 a.Central Unit 24.0 SEER:15.50 SHGC: SHGC=0.32 b.Central Unit 18.0 SEER:15.00 d. U-Factor. N/A ft2 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 24.0 HSPF:9.00 Area Weighted Average Overhang Depth: 1.172 ft. b.Electric Heat Pump 17.7 HSPF:8.50 Area Weighted Average SHGC: 0.302 8. Floor Types Insulation Area 14.Hot water systems a.Electric Cap:40 gallons a.Slab-On-Grade Edge Insulation R=0.0 1793.00 ft2EF:0.95 b.Floor Over Other Space R=0.0 672.00 ft2 c.other(see details) R= 437.00 ft2 b. Conservation features None 15.Credits Pstat certify that this home has complied with the Florida Energy Efficiency Code for Building �86ST Construction through the above energy saving features which will be installed (or exceeded) pit. 9Tho, . in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on.installed Code compliant features. Builder Signature: Date: 05/01/18 4(!' : Address of New Home: 3112 Kr terbrooke Lane City/FL Zip: Zephyrhills,FL 33540` *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 5/1/2018 1:12 PM EnergyGauge®USA-FlaRes2017 -Section R405.4.1 Compliant Software Page 1 of 1 • , I Buildin Analysis Job: 2889A1 sf ADS Carrier g y Date: 51112018 lower floor By: Dave BAYONET PLUMBING COOLING HEATING Project Information For: Lennar Homes Design Conditions Location: Indoor: Heating Cooling Tampa International AP, FL, US Indoor temperature(OF) 70 75 Elevation: 10 ft Design TD (OF) 39 17 Latitude: 28°N Relative humidity(%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 34.7 53.6 Dry bulb(OF) 31 92 Infiltration: Daily range(OF) - 14 ( L ) Method Simplified Wet bulb(OF) - 77 Construction quality Semi-tight Wind speed (mph) 15.0 7.5 Fireplaces 0 ME am Component Btuh/ft2 Btuh % of load Walls 5.5 6957 30.1 °� Glazing 30.2 3426 14.8 Wall nfiltration Doors 21.2 419 1.8 Ceilings 1.3 1450 6.3 Floors 3.3 5951 25.8 Infiltration 2.1 2877 12.5 Ducts 2020 8.7 Piping 0 0 Floors Humidification 0 0 Glazing Ventilation 0 0 Other. Adjustments 0 Ceilings Total 23100 100.0 • • R • Component Btuh/ft2 Btuh % of load Walls 2.9 3724 20.0 Glazing 54.3 6167 33.2 Walls Internal Gains Doors 17.2 340 1.8 Ceilings 1.7 2021 10.9 Floors 0 0 0 Infiltration 0.5 684 3.7 acts Ducts 2360 12.7 Ventilation 0 0 = Internal gains 3290 17.7 Infiltration Blower 0 0 Glazing Adjustments 0 0•ceilings Total 18586 100.0 Other Latent Cooling Load=2305 Btuh Overall U-value= 0.107 Btuh/ft2-OF Data entries checked. -F- =ightsoft® 2018-May-01 13:32:55 Right-Sufte®Universal 2018 18.0.16 RSU05714 Page 1 ..ent\2889A1 sf ADS template 1.5-2ton Carrier.rup Calc=MJ8 Front Door faces:NW Building Anal Job: 2889A1sf ADS Carrier g Y$IS Date: 5/1/2018 upper floor By: Dave BAYONET PLUMBING COOLING HEATING Project Information For: Lennar Homes Design Conditions Location: Indoor: Heating Cooling Tampa International AP, FL, US Indoor temperature(°F) 70 75 Elevation: 10 ft Design TD (OF) 39 17 Latitude: 280N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 34.7 53.6 Dry bulb(OF) 31 92 Infiltration: Daily range(°F) - 14 ( L ) Method Simplified Wet bulb(OF) - 77 Construction quality Semi-tight Wind speed (mph) 15.0 7.5 Fireplaces 0 Component Btuh/ft2 Btuh % of load Walls 3.8 3623 33.1 acts Glazing 30.2 2386 21.8 Doors 0 0 0 wan Ceilings 1.3 1384 12.6 nfilt<ati°n Floors 2.0 30 0.3 Infiltration 2.1 2121 19.4 Ducts 1402 12.8 Piping 0 0 Other Humidification 0 0 Ceilings Ventilation 0 0 Glazing Adjustments 0 Total 10946 100.0 Component Btuh/ft2 Btuh % of load Walls 2.9 2718 20.2 Glazing 52.2 4127 30.7 Wall Internal Gains, Doors 0 0 0 Ceilings 1.7 1874 14.0 Floors 0.9 14 0.1 Infiltration 0.5 504 3.8 Ducts Ducts 1682 12.5 Ventilation 0 0 Internal gains 2510 18.7 infiltration Blower 0 0 Glazing Other Adjustments 0 Ceilings Total 13429 100.0 Latent Cooling Load=2649 Btuh Overall U-value= 0.088 Btuh/ft2-°F Data entries checked. - wrightsoftt� 2018-May-01 13:32:55 Right-Suite®Universal 2018 18.0.16 RSU05714 Page 2 ..ent\288SA1 sf ADS template 1.5-2ton Carrier.rup Calc=MJ8 Front Door faces:NW Project Summary Job: 2889A1 sf ADS Carrier Date: 5/1/2018 lower floor By: Dave BAYONET PLUMBING COOLING HEATING i Proiect Information For: Lennar Homes Notes: FBC 2017 Design Information Weather: Tampa International AP, FL, US Winter Design Conditions Summer Design Conditions. Outside db 31 OF Outside db 92 OF Inside db 70 OF Inside db 75 OF Design TD 39 OF Design TD 17 OF Daily range L Relative humidity 50 % Moisture difference 54 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 21080 Btuh Structure 16227 Btuh Ducts 2020 Btuh Ducts 2360 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 23100 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 18586 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight . Fireplaces 0 Structure 1902 Btuh Ducts 403 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling (none) Area(ft') 1793 1793 Equipment latent load 2305 Btuh Volume(ft') 16024 16024 Air changes/hour 0.25 0.13 Equipment Total Load (Sen+Lat) 20891 Btuh Equiv.AVF (cfm) 67 36 Req. total capacity at'0.85 SHR 1.8 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade Trade Model 25HBC524AO0300 Cond 25HBC524AO0300 AHRI ref 9154943 Coil FB4CNP025L AH R I ref 9154943 Efficiency 9 HSPF Efficiency 12.5 EER, 15.5 SEER Heating input Sensible cooling 20400 Btuh Heating output 24000 Btuh @ 47°F Latent cooling 3600 Btuh Temperature rise 27 OF Total cooling 24000 Btuh Actual air flow 800 cfm Actual air flow 800 cfm Air flow factor 0.035 cfm/Btuh Air flow factor 0.043 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.89 Capacity balance point= 32 OF Backup: Input=6 kW, Output=22126 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -� wrightsof[® 2018-May-0113:32:55 l •�^•� •--••� Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 .9l.Ui ...ent\2889A1 sf ADS template 1.5-2ton Carrierrup Cale=MJ8 Front Door faces:NW Project Summary Job: 2889A1 sf ADS Carrier ry Date: 5/1/2018 upper floor By: Dave BAYONET PLUMBING COOLING HEATING Project Information For: Lennar Homes Notes: FBC 2017 Design Information Weather: Tampa International AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 31 OF Outside db 92 OF Inside db 70 OF Inside db 75 OF Design TD 39 OF Design TD 17 OF Daily range L Relative humidity 50 % Moisture difference 54 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 9545 Btuh Structure 11747 Btuh Ducts 1402 Btuh Ducts 1682 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 10946 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 13429 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 2360 Btuh Ducts 289 Btuh Central vent (0 cfm) 0 Btuh Heatingg Coolingg (none) Area(A') 1103 1103 Equipment latent load 2649 Btuh Volume(ft3) 8824 8824 Air changes/hour 0.33 0.18 Equipment Total Load (Sen+Lat) 16078 Btuh Equiv.AVF (cfm) 49 26 Req. total capacity at 0.85 SHR 1.3 ton Heating Equipment Summary, Cooling Equipment Summary Make Carrier Make Carrier Trade Trade Model 25HBC518AO0300 Cond 25HBC518AO0300 AHRI ref 9154643 Coil F64CNP025L AH R I ref 9154643 Efficiency 8.5 HSPF Efficiency 12.5 EER, 15 SEER Heating input Sensible cooling 15300 Btuh Heating output 17700 Btuh @ 47°F Latent cooling 2700 Btuh Temperature rise 27 OF Total cooling 18000 Btuh Actual air flow 600 cfm Actual air flow 600 cfm Air flow factor 0.055 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.84 Capacity balance point=20 OF Backup: Input= 3 kW, Output= 10697 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. -Fia- wr s ightoft- 2018-May-01 13:32:55 -�^•�• ��• -•-� Right-Suite®Universal 2018 18.0.16 RSUD5714 Page 2 ..ent12889A1 sf ADS template 1.5-2ton Carrierrup Calc=MJ8 Front Door faces:NW Manual S Compliance Report Job: 2889AI sf ADS cameo Date: 511/2018 lower floor By: Dave BAYONET PLUMBING COOLING HEATING Project Information For: Lennar Homes Cooling Equipment Design Conditions Outdoor design DB: 92.4°F Sensible gain: 18586 Btuh Entering coil DB: 75.7°F Outdoor design WB: 77.4°F Latent gain: 2305 Btuh Entering coil WB: 62.9°F Indoor design DB: 75.0°F Total gain: 20891 Btuh Indoor RH: 50% Estimated airflow: 800 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: 25HBC524A00300+FB4CNP025L Actual airflow: 800 cfm Sensible capacity: 20400 Btuh 110% of load Latent capacity: 3600 Btuh 156% of load Total capacity: 24000 Btuh 115% of load SHR: 85% Heating Equipment Design Conditions Outdoor design DB: 30.8°F Heat loss: 23100 Btuh Entering coil DB: 69.6°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: SplitASHP Manufacturer: Carrier Model: 25HBC524A00300+FB4CNP025L Actual airflow: 800 cfm Output capacity: 18304 Btuh 79% of load Capacity balance: 32 °F Supplemental heat required: 4796 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 800 cfm Output capacity: 6.5 kW 96% of load Temp. rise: 50 °F Meets all requirements of ACCA Manual S. 1 wright30ft® 2018-May-0113:32:55 Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1 ACCK ...enfl2889A1 sf ADS template 1.5-2ton Carrier.rup Calc=MJ8 Front Door faces:NW Manual S Compliance Report Job: 2889A1 sf ADS Carrier p p Date: 51112018 upper floor By: Dave BAYONET PLUMBING COOLING HEATING Project Information For: Lennar Homes Cooling Equipment Design Conditions Outdoor design DB: 92.4°F Sensible gain: 13429 Btuh Entering coil DB: 75.8°F Outdoor design WB: 77.4°F Latent gain: 2649 Btuh Entering coil WB: 62.9°F Indoor design DB: 75.0°F Total gain: 16078 Btuh Indoor RH: 50% Estimated airflow: 600 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: SplitASHP ,Manufacturer: Carrier Model: 25HBC518A00300+FB4CNP025L Actual airflow: 600 cfm Sensible capacity: 15300 Btuh 114% of load Latent capacity: 2700 Btuh 102% of load Total capacity: 18000 Btuh 112% of load SHR: 85% Heating Equipment Design Conditions Outdoor design DB: 30.8°F Heat loss: 10946 Btuh Entering coil DB: 69.60-F Indoor design DB: 70.0°F I ' Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: 25HBC518A00300+FB4CNP025L Actual airflow: 600 cfm Output capacity: 13453 Btuh 123% of load Capacity balance: 20 °F Supplemental heat required: 0 Btuh Economic balance: -99 °F Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 600 cfm Output capacity: 3.1 kW 98% of load Temp. rise: 50 °F Meets all requirements of ACCA Manual S. -�- wrightsoft- 2018-May-01 13:32:55 Right-Suite®Universal2018 18.0.16 RSU05714 �CI� Page 2 ...ent\2889A1 sf ADS template 1.5-2ton Carrier.rup Calc=MJ8 Front Door faces:NW Lennar Homes-3112 Kresterbrooke Ln-3,359 sq ft o umn tj SQ. FEET PRICE MAIN OR LIVING: 3,359 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 378,391.35 FEE SHEET $ 1,935.00 ADDRESS $ 40.00 DRIVEWAY $ 40.00 BUILDING: $ 2,053.70 ELECTRICAL: $ 435.38 PLUMBING: $ 290.25 MECHANICAL: $ 203.18 SUB-TOTAL $ 2,982.50 TOTAL $ 2,982.50 SEWER: $ 2,090.00 WATER: $ 1,010.00 IRRIGATION: $ - TOTAL: $ 3,100.00 WATER METER: $ 473.78 IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 7,109.63 PARK IMPACT FEES $ 769.56 SIF'S: $ 7,128.00 100.0% $ 7,128.00 1.0% $ 71.28 TOTAL: $ 7,199.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 18,710.47 Single Family Dwelling P lan Review Comments . . 1: F.F.E. shall be a minimum of 8. above.the road elevation_and an engineered.site plan. 2. Lots shall be graded to comply with R401.3 of the F.B.C. .: . 3.: :C6mpaction west tequired if 24" or more=of fill dirt is brought in:at any one place: - 4.. :Tie in survey required before pouring concrete.. 5.. Dnveways:require a R.D.W. use permit: All 4.sides of driveway thru the sidewalk shall Have. :expansion matenal.. 6.. -All setbacks.shall be met.:. 7. All_property:markers shall be uncovered and marked at time of first inspection: .8. :All A.D.A.-requirements shall be met. . 9. -No electric plumbing , mechanical;-or framing shall be covered without an;inspection and approval first. . 10..All,Garages shall,c6mply:mith;section R302.6:of the F.B.C...(Fire S:eparation). 11:Appliances shall-not:be installed in,a location where sulij ect to`mechanical damage unless protected by approved barriers. M303.4 of the F.B.C. 12. Water heaters shall_comply:with section:P607.3 of the F.B.C. 13. Foundation supports for-A/C.units shall be raised at least 3'.' above finished grade.. M1308.1 14..Retum air'in-all,bedrooihs.-F.B.C. ,M1620.4.. 15::Smoke detectors are.to be installed:in-accordance with'R313:.1 of the.F.B.C. .16: All glazing requirements are'.to be in accordance'with R308.4.of the F.B.C. 17. All means.of egress are'to be in:accordance with R311:of the F.A.C. 18. "Green gypsum board" shall not be used:as.a backer in showers or tubs:R702.462 F.B.C. 19.Combination-typeA.FCI breakers are.required:at all.locations requiring an AFCLtype breaker: 20: Carbon monoxide alarms will.be required in new.construction that uses fossil-burning heating :or appliances or an attached garage:. They shall be.installed in accordance with.the F.B.C.. 21. All plumbing,mechanical, and:electrical shall be sepatate from unit to unit: This includes all, underground plumbing and electric. 22. All 2011.N:E.E. Codes:will.be enforced: 23:-Tamper-Resistant Receptacles in accordance with 406.11-of the 2011 N:E:C 24: In accordance:.with the Land.Development:Code;lots shall be.sodded'before final at least 10. . feet:around-the.structure. 25.A copy of the ener,6 Gaels shall be with permit at all times. 26. Copy of final.insulation'reportsliallbe.provided with.permitbefore-finA .F.E:-Finished Floor Elevation_ F.B.C=Florida Building Code 04 Edition- R.O.W.-Right.of Way A.D:A:-Americans with Disabilities Act N.E.C.-National Electric Code(2011): i PASCO COUNTY, FLORIDA Permit No. 9r1 6 Date Permitted 6 —IS-1 Builder Name/Owner Name t(�nna - Ome— Control#' County Parcel No. ubDiv: C` ddek6'V-r Address/Location 3/1 2- d { l Classiflcation(rype of Use C3ti } e Z/ TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: 3 t 3S2 Exempt ❑Yes ❑ No How Determined impact Fee Amount $. f z © Zone No. TAZ: SCHOOL IMPACT FEE Account (056) Single-Family Detached House Amount $ '71 (057) Mobile Home (058) Other Residential 23) Collection Fee Exempt d Yes ❑ No How Determined PARKS AND RECREATION FEE Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation Total Zone TOTAL AMOUNT $ Exempt ❑Yes ❑ No How Determined LIBRARY FEE Land Account Land Credit Land Total Facility Account Facility Credit Facility Total Exempt ❑Yes ❑ No How.Determined Total Amount RESOURCE FEE ERU TOTAL AMOUNT Prepared By Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE BEEN PAID AND RECEIPTED FOR BY A CENTRAL_PERMITTING OFFICE OF PASCO COUNTY Acknowledgement below does not Imply acceptance of concurrence,but simply receipt of a copy of this form,placing 1 the building permit owner.on notice of this assessment and the conditions of payment for same. DATE RECEIVED BY RECEIPT NO. DATE BY '813-780-0020 City of ZeohV[hi\@; PerrnitAooiicatOD ax-813-780-0021 / ouKd�Vompa�mon Date Received MAY 0 3 2018 Phone Contact for Permlftln 813 363 2891 . . ~ . . n x xu x m x x " �. Owner's Name ��P��w�� .5700 Owner's Address 4600 ress FL 33607 Owner Phone Number Fee Simple Titleholder Name I Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS 13112 Kresterbrooke LaneLu/ * F0760 ���____� Suoomv000m p/o«oEL|o# 24-26-21-0100-00000-0760 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW cowsrn fuoIAcr [---� DxsN F--1 F--� oEmou8o ! INSTALL �_] REPAIR � PROPOSED USE bFR COMM OTHER TYPE orCONSTRUCTION uLocn L_J FRAME L � STEELDESCRIPTION OF WORK Single Family Residence Pool/Screen Enclosure Fence 12 Story U/R IF B~.L~.,.S�^ —Q.--.--_ HEIGHT ~ . ~ . ~ . . . . . . ~ . . . . . . ~ . ~ . ~ . . . . . . ~ . ~ . . ~ ' ~ . ~ . . ' ' . ' - ' ~ ' ' ' ' - ' - ' ' ' ' ' ' - ' - �w, jsU�D|NG VALUATION OF TOTAL CONSTRUCTION J—�IsLsoTn|Q^L M PnoGnEaaewEReY F—� Vxr�E.C. T AMP SERVICE 17-71 ' 1 111PLuM0NG' IV I J-3� ��'lz�6o4�BcHAw|��L VxLU/n7ONDF�ECV�N/oxL|NGT^LU�|ON�w' Y ' F--loxe ROOFING [—� SPECIALTY OTHER CTHER r___1 RLi Do pLoDnZDwExn�� YES o BUILDER COMPANY Lennar Homes,LLC SIGNATURE REGISTERED / Address 4600 FL 33607 Uoonoo# FEZ1518166 ' ! ELECTRICIAN SIGNATURE o _Y/ N_] FEEounns^ L11N_] Address Lioenmo# PLUMBER COMPANY =Bayonet Plumbing, Heating &AC, Inc a|oN*TVme REGISTERED 1/ N_] pssuunnsx , Address Ummoe# MsoHmu|oAL COMPANY Bayonet Plumbing, Heating &AC, a|om/TVms REGISTERED LY2 N_| pesouneE^ LY/NL� Address unnnuo# oTnsn COMPANY a|oNArUms REGISTERED _l/_N_J FEE«unns Address 14211 Shoaffine Bivd, Spring Hill, FL 34607 License# uoxxm000xmumxwoxmnuxmnxnnonmnmnnuomnnnnnnmomumnonuuAmnxunuunowxuxom | RESIDENTIAL Attach(2)Plot P|aoa;.(2)sets of Building Plans;(1)set of Energy Forms;R+]-W Permit for new construction, Minimum ten(1N working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Sift Fence installed, Sanitary Facfli itloo&1dumpmac Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum t (10)working days after b iva/Uate. Required onsite,Construction Plans,Stormwater Plans wl Silt Fence installed, Sanitary Facilities&I durripster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach Vq sets uf Engineered Plans. **°PRopERTYGVRVEY'required for all NEW construction. � Fill out application completely. Owner a Contractor sign back m application,notarized i |f over$m5oo.o Notice m Commencement Is required. VVo upgrades over$nmno> Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarizedletter from owner authorizing same OVER THE COUNTER PERMITTING (copynrcontract required) nomofs|ishingles Sewers Service Upgrades ^/o Fenuom(p|uxGumoy/Fomoge) Driveways-Not over Counter ifon public modwayo'need ROW ' ' ` NOTICE OF DEED RESTRICTIONS: The undersigned underebandothatbhispennit may be a" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any ' applicable deed resdrictiono. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by |avv, both the owherend contractor may be cited for o misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Fudhennone, if the owner has hired e contractor orcontractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. \f you, oo the owner sign oothe contractor, that may bean indication that he is not properly licensed and is not entitled tp permitting privileges in Pasco County. TRANSPORTATION {08P&CT/WTYL|T1ESIMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing bui|dingo, or expansion of existing buUdings, as specified in Pasco County Ordinance number89-O7 and 80'07. as amended. The undersigned also undemtande, that such feeo, as may be due, will be identified st the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery F000 must be paid prior to receiving a "certificate of occupancy" or final power release. \f the project domonmdinvo|vamcetficateofmccupancyor final power release, the fees 0Uot be paid prior to permit issuance. Furthermore, if Pasco CoUntyVVater/Sewar Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, amonmended): |f valuation of work io $2.50U.00or more, | certify that |, the appUcant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. |f the applicant iosomeone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver itiothe"owner" prior tocommencement. CONTRACTOR'S/OWNER!GAFP|DAV|T: | certify that all the information in this application is aouunabo and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. | certify that no work or installation has commenced prior to issuance of permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. ! also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility toidentify what actions | must take tobmincompliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheadn' Wetland Areas and Environmentally Sensitive Lands,VVoten0lhalote'wsbsrTreatment. - Southwest Florida Water Management [3isdhct48e|ka. Cypress Bayhoada, Wetland Anaao, Altering Watercourses. - Army Corps ofEn 'naena-GacwvoUa. Docks, Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-VVeUo, Wastewater Tnasdmont. Septic Tanks.' - UG Environmental Protection Agency-Asbestos abatement. - Federal Aviati Authority-Runways. | understand that the following restrictions apply to the use offill: - Use of fill io not allowed in Flood Zone"tr unless.expressly permitted. - |f the fill material is to be used in Flood Zone 'YY', it is understood that a drainage plan addressing a "compensating volume" will be submitted at time of permitting which is prepared by a pnrhaaoiona| engineer licensed by the State ofFlorida. ' If the fill material is to be used in Flood Zone "A" in connection with a pnnhd±ed building using stem vvaU construction, I certify that fill will be used only to fill the area within the stem wall. - If fill nlotahol is to be used in any area. | certify that use of such fill will not adversely affect properties. |f use of fill |o found to adversely affect adjacent properties, the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill,. an engineered drainage plan iurequired. |f| om the����ENTF��FtTHE OVVNG/4. Iprnmiooih good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. | understand that m separate permit may be required for e|wotrioe| xvork, p|urnbing, oigno, weKo, poo|e, air conditioning, gos, or other installations not opeoUUoo{ly included in the application. A permit issued shall be nnnabaed to be license to proceed with the work and not as authority toviolate, oonoe|, e|ter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit ie suspended or abandoned for e period of six(G) months after the time the work i000rnmonoed. An extension may be naqueebyd, in writing, from the Building Official for a period not to exceed ninety (gO) days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job it considered abandoned. ` WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. OWNER uu AGENT Cwm/=*u/v Subscribed and sworn to(or a ir )before me this Subscribed and sworn to(or d)before me this WEo is/are personally known to me or aslhav6 pi:educeed- Who is/are personally known to me or4%vjAiave-PF8dHEe as identification. -as identification. Notary Public Notary Public Commission No. FF98537 Z-ermn|uoinnNu fF98537 EUisouM.Holleran 8liooa' M.BoD,zuo 24-26-21-0100-00000-0760 Pasco County Property Appraiser Page 1 of 1 Data Current as Of: Weekly Archive - Monday, June 11, 2018 Parcel ID 24-26-21-0100-00000-0760 (Card: 001 of 001) Classification 00 - Vacant Residential Mailing Address Property Value LENNAR HOMES LLC Ag Land $0 4600 W CYPRESS ST STE 200 Land $29,180 TAMPA FL 33607-4099 Building $0 Physical Address Extra Features $0 3112 KRESTERBROOKE LANE ZEPHYRHILLS, FL 33540 3ust Value $29,180 Legal Description (First 4'Lines) Assessed (Non-School Amendment 1) $29,180 HIDDEN RIVER PHASE ONE B PB 76 PG 077 LOT 76 Taxable Value $29,180 OR 9737 PG 3770 3urisdiction City of Zeghyrhills Land Detail (Card: 001 of 001) Line Use Descrip font Zoning Units 11Type __ P lCondition ;Value 1 0100 SFR MPUD 6,000.00 SF $4.75 1.00 ( $28,500 2 0100 SFR j MPUD 756.00 SF $0.90 1.00 $680 _ Additional Land_ Infor_m_ation FEMA Acres 0.16 [Tax Area 30ZH Code Residential Code HDRVCPI Building Information --Use 00 - Unimproved (Card: 001 of 001) Unimproved Parcel 00 - Unimproved _ Extra Features (Card: 001 of 001) Line _ — Description Year _ Units ;Value No Extra Features Sales History- See All 6 sales Previous Owner: DUNE FL LAND I SUB LLC Month/Year Book/Page Type lCondition 'Amount 06/2018 9737 / 3770 Warranty Deed 05 Vacant E Multi-Parcel Sale 09/2011 8606 / 3376 Warranty Deed 05 Vacant Multi-Parcel Sale 06/2010 8360 / 1872 Certificate of Title j 12 Vacant ; $0 http://search.pascopa.com/parcel.aspx?parcel=2126240100000000760 6/15/2018 . �` �.� j `�, '�t ray• a R s y • a �,,��,.•''' tsl. `r • ice"' ' "e � '�. � �"� �•� � °�� for �01 Vol Alt 10 .01 9-0 Ir ve . ♦'1` Ei tl U 0 lickiU�1�U�4n� w1A.,-' .IWI-A fib uutl�t�P U11+ •3a3 ' 4�AZI�SSGGtP pt� ,yt�Sl Afl X'J 6S u199 E.„Ka1��`'A 4A I�AyN4z�1t ��+uuk�• �4 PLOT PLAN SKETCH ONLY NOT A BOUNDARY SURVEY _ SEC. 24 TWP. 26 S. RN LOT 76 BEARING BASIS: HIDDEN RIVER PHASE ONE B NORTH BOUNDARY OF SUBJECT PLAT BEING S 89'40' PASCO COUNTY, FLORIDA. THIS SURVEY IS SUBJECT TO ANY FACT T MAY BE DISCLOSED BY A FULL AND AC PRELIMINARY DRAWING: 1� TITLE SEARCH. ALSO SUBJECT TO SETBA THIS PLAN IS FOR PERMITTING PURPOSES EASEMENTS AND RESTRICTIONS OF RECORD. ONLY, NOT FOR CONSTRUCTION. VERIFY ALL DIMENSIONS BEFORE ANY CONSTRUCTION. o' UNDERGROUND FOOTER, STEM WALL, A UNDERGROUND UTILITIES ARE NOT LOCATED 0 II LEGEND: SHOWN. PROPOSED DRAINAGE FLOW DO NOT SCALE THIS PRINT. DIMENSIONS AND (00.00) = PROPOSED GRADE _wj NOTES TAKE PREFERENCE. E-00.00 = EXISTING GRADE DESCRIPTION NOT CONTAINING PLAT BOOK AND NOTES: PAGE INDICATES THAT PLAT IS IN LOT GRADING TYPE = A PRELIMINARY STAGE AND IS SUBJECT TO PROPOSED PAD ELEVATION N/A CHANGE AND/OR REVISION. FRONT SETBACK = 20' CERTAIN DATA 'SHOWN HEREON BASED ON SIDE SETBACK = 10' ENGINEERING PLANS PROVIDED BY CLIENT. REAR SETBACK = 10' STRUCTURE TIES SHOWN HEREON DENOTES / MEASUREMENT FROM FORM BOARDS/FOUNDATION TO PROPERTY LINE. / * = 10' DRAINAGE/UTILITY EASEMENT / /PL�� BOUNDARY i r• �O D. l9. 1• J LOT 77 iP'•. (70.831 dam•. '° .'t;•, ° �p G•y6 ., gyp. O�1O so o�?�, OO ROe0`3 c Z Q e�$�9•P� PLAT BOUNDARY 1-110. ON LOT AREA CALCULATIONS LOT = 6756.17_SQ. FT. �o S 76'0239• / LIVING AREA = 177_9___SQ. FT. c^ no 26."': •.E, ENTRY =_26—SQ. FT. g1 PI GARAGE = 406�SQ. FT. �y yoo PT° COVERED LANAI = N A LOT 75 ----SQ. FT. �( �h e °o. °o• (70.00') PATIO =__23 ___SQ. FT. CONC. DRIVE =_263 __SQ. FT. 0 \ LOT 76 �—PRM(P) A/C & CONC PAD = 18 SQ. FT. O� 5ya,3:•. (�) PRIVATE SIDEWALK =_-36 __SQ. FT. IMPERVIOUS = 39 q, fn: c'i N -_2646_--SQ. FT. m .°o. G1 SOD =_41 TO __SQ. FT. 10:vi p.N OFF LOT AREA CALCULATIONS y: RIGHT OF WAY = 709.85_SQ. FT. (71.35')- DRIVE APRON =-144___SQ. FT. �o TRACT "B" _ o HIDDEN RIVER PHASE ONE A PUBLIC SIDEWALK = 239 SQ. . \O (PLAT BOOK 74, PAGES 101-121) FT SOD =_ 327 -SQ. FT. j WETLAND CONSERVATION TOTALS AREA =__7466 02 SQ. FT. DRIVEWAY =_507 —SQ. FT. ' SIDEWALK = 270 __SQ. FT. SOD = 4437 -SQ. FT. DESCRIPTION: PROPOSED: LOT 76, MAP OR PLAT ENTITLED "HIDDEN RIVER PHASE ONE B", LOWEST FLOOR ELEVATIONS: AS RECORDED IN PLAT BOOK __ PAGES ___ THROUGH LIVING AREA: 72.10' OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. GARAGE AREA: N/A ELEVATIONS REFERENCED TO, CURVE IRADIUS ARC CHORD BEARING DELTA NATIONAL GEODETIC VERTICAL C14 1 500.00' 75.07' 75.00' S 55.00'37° W 08'36'09" DATUM OF 1929. MEAN SEA C36 400.00' 37.03' 37.02' N 61'57'49" E 05-18.16" LEVEL= 00.00 FT. C37 400.00' 60.06' 60.00' N 55'00'37" E OS'36'09" APPARENT FLOOD HAZARD ZONE: "X" COMMUNITY PANEL NO. 120230 0460 D EFFECTIVE DATE: 9/30/1992 LEGEND: (C)= CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, %= CENTERLINE, A/C= AIR CONDITIONER, B/C= BACK OF CURB, C/S= CONCRETE SLAB, CH= CHORD, CHB=,CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= COVERED, E/P= EDGE OF PAVEMENT, ESM'T= EASEMENT, F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE, FIR= FOUND IRON ROD, FN&D= FOUND NAIL & DISK, FPP= FOUND PINCHED PIPE, LFE= LOWEST FLOOR ELEVATION, MAS.= MASONRY, OR= OFFICIAL RECORD BOOK, PB= PLAT BOOK, PCP= PERMANENT CONTROL POINT, PRM= PERMANENT REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & CAP No. 4493, SN&D= SET NAIL & DISK, TBM= TEMPORARY BENCHMARK, U P= UTILITY POLE W F= WOOD FENCE, R = RADIAL JOHN R.BEACH&ASSOCIATES,INC. Drawn By: SMS Square Feet: 6756.17 t LENNAR HOMES SURVEYORS AND MAPPERS Checked By: 911 WEST ST. PETERSBURG DRIVE JRB ONE OLDSMAR, FLORIDA 34677 WAY (813) 854-1276 FAX (813) 855-8370 Scale: 1"=30' NOT VALID WITHOUT THE SIGNATURE AND jDate of Survey: THE ORIGINAL RAISED SEAL OF A FLORIDA PLOT PLAN 04/18/2018 RTM OH R. BEACH DATE LICENSED SURVEYOR AND MAPPER FLORID REG. LAND SURVEYOR No. 2984 LB 4493 Revisions: Jacqueline Boges ' From: Nichole Spence(City of Zephyrhills Support)<support@zephyrhillsfl.zendesk.com> Sent: Friday, July 13, 2018 6:37 PM To: Jacqueline Boges Subject: [FATHOM] Re: 3112 Kresterbrooke lane by#19804 ##- Please type your reply above this line -## Your request (#223466) has been updated. REPLY TO THIS EMAIL or click the link below: https://zephvrhillsff.zendesk.com/hc/requests/`223466 .................................................................................................................................................................................................................................................................................................................................................................................... Nichole Spence (City of Zephyrhills Support ) L. Jul 13, 3:37 PM MST Account# 2996759 has been created; service order to follow once mapping has been completed. Best Regards, Nichole I FATHOM Support ............................................................................................... .................. ................................................................................................................................................................................................................................................ i Jacqueline Boges -- Jun 29, 9:18 AM MST full service 3112 Kresterbrooke Lane by#19804 water, sewer, water meter This email is a service from City of Zephyrhills Support . 1 Jacquehne Borges ' From: Nichole Spence(City of Zephyrhills Support)<support@zephyrhillsfl.zendesk.com> Sent: Saturday, July 14, 2018 11:50 AM To: Jacqueline Boges Subject: [FATHOM] Re: 3112 Kresterbrooke lane by#19804 ##- Please type your reply above this line -## Your request (#223466) has been solved. TO REOPEN THIS REQUEST, reply to this email or click the link below: https://zephyrhilisfl.zendesk.com/hc/requests/223466 ..................................................................................................................................................................................................................................................................................................................................................................................... Nichole Spence (City of Zephyrhills Support ) ----- -_ Jul 14, 8:49 AM MST Hello Jacqueline Boges, The changes you requested have been completed. I am marking this ticket as solved. Best Regards, Nichole I FATHOM Support ...................................................................................................................................................................................................................................................................................................................................................................................... Nichole Spence (City of Zephyrhills Support ) Jul 13, 3:37 PM MST Account# 2996759 has been created; service order to follow once mapping has been completed. Best Regards, Nichole I FATHOM Support ....................................................................................................................................................................................................................................................................................................................................................................................... f Jacqueline Boges Jun 29, 9:18 AM MST full service 3112 Kresterbrooke Lane by#19804 water, sewer, water meter This email is a service from City of Zephyrhills Support . i PASCO COUNTY DEVELOPMENT SERVICES PAS 8731 Citizens Drive Date:6/7/2018 COUNTY FLORIDA New PortAlchey,FL 3465-4 -OPEIVs li-A—CES-.VtBmRf IiiACES. ----'727-847-241-1-- ----- NOT A .rERMIT Receipt#: 1782471 FEE.DESCRIPTION ACCOUNT CODE UNITS INVOICE# FEE AMOUNT PAID RECEIPT# DATE Impact Fee Residential Solid 24503100-329010* 25.50 1372036 $25.50- $25.50* 1782471 817/18 Waste Single Family 3112 KRESTERBROOKE LANE. TOTALS: $25.60 $25.50 Receipt# Paid By Check# CC Atith# Cashier ID Workstation Receipt Date Amt Paid 1.182471 Check 01012,9753 554 BCCC,P58W 08/07/2018 :$25.50 Total Payments: $25.50 Pavor Address Phone. LENNAR HOMES LLG 'Comments: 3112 KRESTERBROOKE LANE While you will be paying your.' bill with Pasco County Development Services,the full amount of the credit card or e-check fees,NOT shown above,Is collected by First Billing payment services. 62895856 Lennar Hoi-nii.§,,LLC JPMorgan Chase Bank N.A. STUB CHECKNO. 1029753 INVOICE 900000.1010.114 1 of. I DATE 08/02/18 'Co.It NUMBER DATE PAYMEM-AMCE GROSS DISCOUNT - NET 1504. 15174720076.401435 077418 15174720016 4014:35 $25.50 $0100 $25,50 330 1971507 Pasco County SOCC 7 Little Road.Port Richey FL 33553-9600, $25.50 $0.00 $25.50 MyReports/reports//PASCOPRobipAsr-O/ReceiptPOS- 8/7/2018" Page 1 of 1 CITY OF " NOTICE ' / / BUILDING ZEPHYRHII.LS DEPARTMENT OF ADDITION OR CORRECTION M • NOT REMOVE .! ADDRESS DATE PERMIT r�f.Ve -6 f 7/1 z J / :THIS JOB HAS NOT BEEN COMPLETED. The following additions or corrections shall be made before the job will be accepted. It'is unlawful for ariy.Carperite�,Co�t"tradoi,Builder,or other persons;,to AFTER CORRECTIONS ARE MADE CALL "dove or 6a4se,to be.,coveretf any:,part'of the'worii with`flooring lath;earth:;`.:.:. ort5therkmateriai,_untii'the-proper.inspector has had,ampie time to appro4e.,= .. = 'T80=QQ20-F PECTION the installation. L OFFICE HOURS 7:30AM-4:30 PM MON:FRI. INSPECTOR`' 5335 - 8TH STREET (813)780-0020 CERTIFICATE OF OCCUPANCY I Address: 3112 KRESTERBROOKE LANE Owner: LENNAR HOMES LLC ZEPHYRHILLS, FL. 4600 W CYPRESS ST STE 200 Subdiv: HIDDEN RIVER TAMPA FL 33607-4099 Parcel: 24-26-21-0100-00000-0760 Work Type: 101-NEW CONST/SFR Construction Type: NOT APPLICABLE ❑ Sprinklers Use Classification: NOT APPLICABLE Permit Number: 19804 Date- 1 16/2018 00-elve- FLZ iEazgel ISSUED B BUILDI OFFICIAL : WATER MUST BE CHANGED OVER WITHIN 10 DAYS OF ISSUANCE GARBAGE DEPOSIT MUST BE APPLIED FOR PRIOR TO ISSUANCE