HomeMy WebLinkAbout18-19806 CITY OF ZEPHYRHILLS
5335-8TH STREET
(813)780-0020 19806
BUILDING PERMIT SINGLE FAMILY RESIDENTIAL
PERMIT INFORMATION . I LOCATION INFORMATION
Permit#:19806 Issued: 6/25/2018 Address: 3124 KRESTERBROOKE LANE
Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL.
Class of Work: 101-NEW CONST/SFR Township: Range:
Proposed Use: NOT APPLICABLE Lot(s): Block: Section:
Sq. Feet: Est. Value: Book: Page:
Cost: 342,906.60 Total Fees: 18,435.47 Subdivision: HIDDEN RIVER
Amount Paid: 18,435.47 Date Paid: 6/25/20181 Parcel Number: 24-26-21-0100-00000-0770
CONTRACTOR INFORMATION OWNER INFORMATION
Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC
Addr: 4600 W. CYPRESS ST STE 200 Address: 4600 W CYPRESS ST STE 200
TAMPA, FL. 33607 TAMPA FL 33607-4099
Phone: (813)574-5743 Lic: Phone: 813-574-5700
Work Desc: CONSTRUCT SINGLE FAMILY 3,044 SQ FT
APPLICATION FEES
BUILDING FEE 1,865.09 ELECTRICAL FEE 394.88 PLUMBING FEE 263.25
MECHANICAL FEE 184.28 SEWER CONNECTION RESIDEW 2,090.00 WATER CONNECTION RESIDENI 1,010.00
WATER METER RES 3/4" 473.78 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00
PARK FEES SF 769.56 PUBLIC SAFETY 5% 26.35 SCHOOL-SFR NEW 1% 71.28
TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32 SCHOOL IMPACT FEE NEW 7,128.00
DA
Inspections Required
FOOTER 2ND ROUGH PLUMB MI INSULATION CEILING
FOOTER BOND DUCTS INSULATED SEWER MISC.
ROUGH ELECTRIC LINTEL MISC MISC.
1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC.
DUCTS INSTALLED WATER MISC DRIVEWAY
PRE-SLAB SHEATHING MISC. MISC.
CONSTRUCTION POLE FRAME MISC. MISC.
REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES:
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: .Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing,consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance
with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.'O.
CONTRACTORS SIGNATURE PERMIT OFFI
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021
Building Department
Date Received MAY 0 3 20� Phone Contact for Permiftin, 813 363 2891
LLCe Ho
mes,oms,
Owner's Name L Owner Phone Number 813,574,5700
Owner's Address 4600 W.Cypress St.Ste.200,Tampa,FL 33607 Owner Phone Number F
Fee Simple Titleholder Name N/A Owner Phone Number
Fee Simple Titleholder Address N/A
JOB ADDRESS 13124 Kresterbrooke Lane LOT# 0770
SUBDIVISION Hidden River Phase One A PARCEL ID# 24-26-21-0100-00000-0770
(OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED NEW CONSTR R ADD/ALT 0 SIGN DEMOLISH
P INSTALL REPAIR
PROPOSED USE n,( SFR Q COMM OTHER
TYPE OF CONSTRUCTION In/ BLOCK Q, FRAME STEEL Q F77
DESCRIPTION OF WORK Single Family Residence Pool Screen Enclosure Fence
BUILDING SIZE SF 3046 SO FOOTAGE HEIGHT 12 Story 25$4
JOBUILDING 1 1 VALUATION OF TOTAL CONSTRUCTION
ELECTRICAL 1$ PROGRESS ENERGY W.R.E.C.
AMP SERVICE
r__71
If / IPLUMBING $
il.tj I W�eo,
ZMECHANICAL 1$ VALUATION OF MECHANICAL INSTALLATION
=GAS W1 ROOFING Q SPECIALTY = OTHER
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA El YES 0 D
BUILDER COMPANY Lermar Homes,LLC.
SIGNATURE REGISTERED Y/ N FEE CURREN
Address 14600 W.Cypr5nt.Ste.200,Tampa,FL 33667 License# F'GC1518166
ELECTRICIAN COMPANY dmLo ns 0 n Electric, Inc.
SIGNATURE REGISTERED Y/ N FEE CURREN
Address 11034 Skiprer Road,Tampa, FL 33613 License# FEC13005408
PLUMBER COMPANY Bayonet Plumbing, Heating &AC, Inc
SIGNATURE REGISTERED Y/ N J FEE CURREN I Y/N
Address P.O. Box A8, Bayonet, FL 34674-5308 License# I CFC042998
MECHANICAL COMPANY Bayonet Plumbing, Heating &AC
SIGNATURE REGISTERED Y/ N FEE CURREN Y/N
Address P.O. Box 5f0-8, Bayonet, FL 34674-5308 License# I CAC058062
OTHER COMPANY
SIGNATURE REGISTERED Y/ N FEE CURREN
Address 14211 Shoal L rine Blvd, Spring Hill, FL 34607 License# FCCC057991
RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction,
Minimum ten(10)working.days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities&I dumpster;Site Work Permit for subdivisions/large projects
COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction.
Minimum ten(10)working,days.after submittal date. Required onsite,Construction Plans,St6rmwater Plans w/Silt Fence Installed,
Sanitary'Facilities&1 dump§ter.Site Work Permit for all new projects.All commercial requirements must meet compliance
SIGN PERMIT Attach
ach(2)sets of Engineered Plans.
.*.*PROPERTY SURVEY required for all NEW construction.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . .
6IrG_c_tI6ns_:- - - - - - - - - - - - - - - - - - - - - - - -- - - -
Fill out application completely.
Owner&Contractor sign back of application,notarized
If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500)
Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (copy of contract required)
Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage)
Driveways-Not over Counter if on public roadways..needs ROW
NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed" restrictions"
which may be more restrictive-than County regulations. The undersigned assumes responsibility for compliance with any
applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or
contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the
contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation
under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the
intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847-
8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign
portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the
contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco
County.
TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of
use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and
90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of
permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to
receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or
final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact
fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I
certify that I,- the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's
Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone
other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to
deliver it to the"owner" prior to commencement.
CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work
will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is
hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has
commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating
construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also
certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is
my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to:
- Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands, WaterMlastewater Treatment.
- Southwest Florida 'Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering
Watercourses.
- Army Corps of Engineers-Seawalls, Docks, Navigable Waterways.
- Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment,
Septic Tanks.
US Environmental Protection Agency-Asbestos abatement.
Federal Aviation Authority-Runways.
I understand that the following restrictions apply to the use of fill:
- Use of fill is not allowed in Flood Zone W" unless expressly permitted.
- If the fill material is to. be used in Flood Zone "A", it is understood that a drainage plan addressing a
"compensating volume" will be submitted at time of permitting which is prepared by a professional engineer
licensed by the State of Florida.
- If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall
construction, I certify that fill will be used only to fill the area within the stem wall.
- If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots less than one'(1)
acre which are elevated by fill, an engineered drainage plan is required.
If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in
this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work,
plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A
permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or
set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter
requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid
unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by
the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension
may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate
justifiable cause for the extension. If work ceases for ninety (90) consecutive days, the job is considered abandoned.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
FLORIDA JURAT(F.S.117.03)
OWNER OR AGENT CONTRACTOR
Subscribed and sworn to(or a )before me this Subscribed and sworn to(or ed)before me this—
ou-mpr-io byn- � LFE - CC S/.1.t� 30-Ap,18 by AS1/LEE roeers,NNy'LJ
Who is/are personally known to me or hasihave pradased Who is/are personally known to me or
as identification. as identification.
Notary Public Notary Public
Commission No. FF98537 Commission No. FF98537
Elissa M.Holleran Elissa M.Holleran
Name of Notary tvped.printed or stamped Name of Notary typed,printed or stamped
�t111�4k.IN>?l��lTI�1V
a,��RmY�nrl$.Fj�uls�4a�" i w�'��tri�on�liP�ulaepa
�E1Rk�.ra�tlt��'�9�0 '!IispMtadur��12¢�Ii
., &F9��1'EhN'PJ6�Ftll4di19Fi98i�k1 �f �
_ _ Cadd$Y��'t�r�1d4411fiR4i12iWfit(I - - -- _ !
City of Zephyrhills
BUILDING PLAN REVIEW COMMENTS
Contractor/Homeowner:
Date Received:
Site: 0 (� 31 2`T ki-es4,1-mk, Ld
Permit Type: Gr,L
Approved w/no comments:❑ Approved w/the below comments: Denied w/the below comments: ❑
/���
This comment sheet shall be kept with the permit and/or plans.
Kalvin Swi4e'r' —P s Examiner Date C ntrac or and/or Homeowner
(Required when comments are present)
PASCO COUNTY, W LORIDA
_ Permit No. q
Date Permitted
Builder Name/Owner Name
.�ontrot# ,
County Parcel No. 2 +ro- .2/!� d ^L�G?Lx -d ubDiv:
Address/Location 3 Z Lt K.te- 4 1e-
Classification/Type of Use 6LYY r e- r,GL�� b`t-�
TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: o 7
Exempt ❑Yes ❑ No How Determined
Impact Fee Amount Z•t� Zone No. TAZ:
SCHOOL IMPACT FEE -7 /�
Account (056) Single-Family Detached House Amount $ �,
(057) Mobile Home
(058) Other Residential
123) Collection Fee
Exempt [� Yes ❑No How Determined
PARKS AND RECREATION FEE
Land Account Land Credit Land Total
Recreation Account Recreation Credit Recreatio-nn Total
Zone TOTAL AMOUNT $ 16 9,5f
Exempt ❑Yes ❑ No How Determined
LIBRARY FEE
Land Account Land Credit Land Total
Facility Account Facility Credit Facility Total _ � .
Exempt ❑Yes ❑ No How Determined Total Amount-'C./
RESOURCE FEE ERU
TOTAL AMOUNT
Prepared By _ Checked By
NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION
PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE
BEEN N PAID AND
RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE.OF PASCO COUNTY
Acknowledgement below does not imply acceptance of concurrence,but simply receipt of•a copy of this form,placing
the building permit owner.on notice of this assessment and the conditions of payment for same.
DATE RECEIVED BY
RECEIPT NO. DATE BY
Lennar Homes-3124 Kresterbrooke Lane-3,044 sq ft
o umn
SO. FEET PRICE
MAIN OR LIVING: 3,044 $ 112.65
OTHER AREA UNDER ROOF: - $ 88.00
OTHER: - $ -
VALUATION $ 342,906.60
FEE SHEET $ 1,755.00
ADDRESS $ 30.00
DRIVEWAY $ 45.00
BUILDING: $ 1,865.10
ELECTRICAL: $ 394.88
PLUMBING: $ 263.25
MECHANICAL: $ 184.28
SUB-TOTAL $ 2,707.50
TOTAL $ 2,707.50
SEWER: $ 2,090.00
WATER: $ 1,010.00
IRRIGATION: $ -
TOTAL: $ 3,100.00
WATER METER: $ 473.78
IRRIGATION METER
FIRE DEPARTMENT FEES
PLANS TOTAL: n/a
INSPECTION TOTAL:
PERMIT TOTAL
TOTAL: $ -
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
FIRE $ 273.00
5% $ 26.35
TOTAL: $ 553.35
SUB-TOTAL $ 6'834.63
PARK IMPACT FEES $ 769.56
SIF'S: $ 7,128.00
100.0% $ 7,128.00
1.0% $ 71.28
TOTAL: $ 7,199.28
T I F'S: $ 3,632.00
99% $ 3,595.68
1% $ 36.32
TOTAL: $ 18,435.47
Lennar Homes-3124 Kresterbrooke Ln-3,044 sq ft
Column ts
SQ. FEET PRICE
MAIN OR LIVING: 3,044 $ 112.65
OTHER AREA UNDER ROOF: - $ 88.00
OTHER: - $ -
VALUATION $ 342,906.60
FEE SHEET $ 1,755.00
ADDRESS $ 40.00
DRIVEWAY $ 40.00
BUILDING: $ 1,870.10
ELECTRICAL: $ 394.88
PLUMBING: $ 263.25
MECHANICAL: $ 184.28
SUB-TOTAL $ 2,712.50
TOTAL $ 2,712.50
SEWER: $ 2,090.00
WATER: $ 1,010.00
IRRIGATION: $ -
TOTAL: $ 3,100.00
WATER METER: $ 473.78
IRRIGATION METER $ -
FIRE DEPARTMENT FEES
PLANS TOTAL: n/a
INSPECTION TOTAL:
PERMIT TOTAL
TOTAL: $ -
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
FIRE $ 273.00
5% $ 26.35
TOTAL: $ 553.35
SUB-TOTAL $ 6,839.63
PARK IMPACT FEES $ 769.56
SIF'S: $ 7,128.00
100.0% $ 7,128.00
1.0% $ 71.28
TOTAL: $ 7,199.28
T I F'S: $ 3,632.00
99% $ 3,595.68
1% $ 36.32
TOTAL: $ 18,440.47
Sin le Famll Dwelhn
Y g
Plan Review Comments
1: F.F:E. shall be a.minimum.of.8",above"the road elevation and an engineered site plan.
-2. Lots-shall be-graded to,comply with R401.3 of the F.B,C:
3. Compaction test required if 24"-or more of fill dirt is.brought in=at any one place:. -
4. 1 Tie in survey required before pouring concrete.
5. Driveways.require a R:O.W. use permit:. All 4.sides of driveway thru the sidewalk shall have
expansion material:
6.. All setbacks.shall be met.:. .
7.: All property markers shall be. 'uncovered and marked.at time'of first inspection:
8:. All A.D.A. requirements shall be met. .
9. No:electric; plumbing, mechanical; or framing shall be:covered without an inspection and
approval first..
10. All Garages shall:comply with:section R302:6 of,the F.B:C:.(Fire Separation)..
11.Appliances:shall not:be installed in a location where subject to.mechanical darnage unless
protected:byapproved barriers-. -M303.4 of the F.B:C :.
12. Water heaters shall comply:with section P607.3 of the F.B.C:
13. Foundation supports for.A/C.units shall-be raised at least 3" above finished grade.. M1308.-1
14.Return air in all_bedrooins. F.B.C. .M-1620.4
15.Smoke detecfors are to be iristailed:in accordance.with:R313:1 of the:F.B.C.
16.:.All glazing re q uironients are:.to be in accordance with R308'A of the F.B.C. ...
IT All means of egress are to:bein accordance with R31.1 of the RB.C., :.
18. `.`Green gypsum board" shall not be used as a backer.in showers or tubs. R702.4:2.F.B.C.
19. Combination-type A.M.breakers are,required at all locations requiring an AFCI type breaker:
20:-Carbon monoxide alarms will be required in.new construction-that uses fossil-burning heating
or appliances or art attached garage.: They shall be,installed in accordance with.the RB.C:
21. All plumbing,mechanieal,:and_electrical shall be separate from unit.to:unit: This includes all. .
underground plumbing and electric:
22. All 2011.N.E:C: Codes.Will.be enforced:.
.23.Tamper-Resistant Receptacles in accordance with 406.11 of the 2011 ME:C
24.:In accordance with the Land:Developmeht:Code. lots.shall be,sodded before final at least 10. .
feet.around the.structure:
25 A.tour of the energy cacls shall be with wern:it at all times
26 Copy of final insulation report shall be.provided with-Pernnit before finab .
F:F.E:-Finished Floor Elevation.
F.B:C-Florida Building,Code 6t':Edition
R.O.W.-Right of Way -
A.D.A.-Americans-with Disabilities Act , N.E.C.-National Electric Code(2011)
MATCH LINE "D" SHEET 1 Now plow won"
y # ._...
EL
fry M k \'FFEL
- -
Y1b �• ! FF�. .{r-h-y,,:+�.ra .r 1"7 V «, A
lip
ifl �t '• i 1 , �`k.." Y X9 t �}.!- , ! 2! t••Of
S TT T1. rn. IM1 " 2
y 1�. - .. FF�. + r `. °'. t.6.Vf' I � �+,a.. i �.� ~ a".ti
309
s A FF a
1 7irIJ�F 5� 4 t+w,r■�"F.rr•�11 '� ti3 t! �' „• �rA8 i''� ��'+.•„��
73
�x
Krf;
1�aE4 t 74rFF 1 ` MTV ! • r �s •. a {• "L� �•.ee., ,t��_" t' *' "`�+�•.~� GGIV
LAU
S.
307 ' •m
. 3 G.$'"'aS I' •i 4 it
•�iJ 3 �Z.� �`^ - M�.1 ���� t.. _.
Lb
FF EL •�' t
`e30 /� r r i a i a. .'• i sx � ,�,e....^o.r• `c e„..••.�o
,i•". '."r �' ,P� � � wry,! "" r" o+ .,� "7,• "rr:J,,..
3 �:.
,�9] 4 A• A ar A 6 ■
7di5f -w a .tY a r. s. ea w' t ,}55 lei
.SFr„y" !_ _ �"'� O ! ' �. ,• �t� V'dy, Aq,
F�'� �.A+G�r:�l • a m o a r 'm a j y w^'
v � � +1{ �• � � x,r '.r 4 as ca m a y� � t� .+s r� :.. -r e�!�Ly A� .. .... . .. ...
JI-7 _ f
r -
PLOT PLAN SKETCH ONLY NOT A BOUNDARY,.,SURVEY :SEC. 24 i , TWP. 26 S, RNG, 21 E.
LOT 77 -'r-.BEARING BASIS: I
I
HIDDEN RIVER PHASE ONE B NORTH BOUNDARY] OF SUBJECT PLAT BEING S 89'40'43" E
PASCO COUNTY, FLORIDA. I T} IS SURVEY IS SUBJECT TO ANY FACTS THAT
MAY BE DISCLOSED BY A FULL AND ACCURATE
ON LOT AREA CALCULATIONS TITLE SEARCH. ALSO SUBJECT TO SETBACKS,
LOT = 839Q,,81 SQ. FT. EASEMENTS AND RESTRICTIONS OF RECORD.
LIVING AREA 1093 __SQ. FT.
35^
ENTRY = _-SQ. FT. M UNDERGROUND FOOTER, STEM WALL, AND
GARAGE = 427___SQ. FT. UNDERGROUND UTILITIES ARE NOT LOCATED OR
COVERED LANAI =--NSA___SQ, FT. 11 SHOWN.
PATIO - 23----SO. FT. DO NOT SCALE THIS PRINT. DIMENSIONS' AND
CONC. DRIVE = 410 __SQ, FT, NOTES TAKE PREFERENCE.
A/C & CONC PAD = 1$ —SQ. FT.
PRIVATE SIDEWALK =�31 - SQ. FT. DESCRIPTION NOT CONTAINING PLAT BOOK AND
IMPERVIOUS =-_24_ __% ch
PAGE INDICATES THAT PLAT IS IN
ZQ37 __5Q. FT. t PRELIMINARY STAGE AND IS SUBJECT TO
SOD =^6384 �SQ. FT, CHANGE AND/OR REVISION.
OFF LOT AREA CALCULATIONS CERTAIN DATA SHOWN HEREON BASED ON
RIGHT OF WAY = 79_2_64 SQ. FT. ENGINEERING PLANS PROVIDED BY CLIENT.
DRIVE APRON 144__SQ. FT.
PUBLIC SIDEWALK =_ 267 —SQ. FT. STRUCTURE TIES SHOWN HEREON DENOTES
SOD =_ 382---SQ. FT. / MEASUREMENT FROM FORM BOARDS/FOUNDATION
`/ TO PROPERTY LINE.
TOTALS PRELIMINARY DRAWING:
AREA -_ 9183_45 SQ. FT. !- THIS PLAN IS FOR PERMITTING PURPOSES
DRIVEWAY = 554--SQ. FT. (/ _ LAT ONLY, NOT FOR CONSTRUCTION. VERIFY
SIDEWALK =?9$ SQ. FT. ALL DIMENSIONS BEFORE ANY CONSTRUCTION.
SOD __ 6766_—SQ. FT. UNDARY .
NOTES: p / LEGEND:
LOT GRADING TYPE = A �ry� 1 - y-= PROPOSED DRAINAGE FLOW
PROPOSED PAD ELEVATION = N/A F C'� ?sp, (00.00) = PROPOSED GRADE
FRONT SETBACK = 20' p E-00.00 = EXISTING GRADE
SIDE SETBACK = 10' 4¢QP� * = 10' DRAINAGE/UTILITY EASEMENT
REAR SETBACK = 10' �l2vo L�q ° (70.49') ** = 10' DRAINAGE EASEMENT
/ /{� ,s, LOT 78
o s
PLAT
(70.65') r?S a�p `o•.�« �\�� �• BOUNDARY
i 'sue:•. �F 1c�a fi S�•\
O
-(71.00')
'per.'•-. �
LOT 77
PC(P)PRM(P) LOT 76
70 . p.1.
10'Q
J
'•,'a, TRACT "B"
HIDDEN RIVER PHASE ONE A
(PLAT BOOK 74, PAGES 101-121)
(71 A 5') Q WEI LAND CONSERVATION
EA
(70.00')
/ ff'—PRM(P)
/ (TYP)
DESCRIPTION: PROPOSED:
LOWEST FLOOR ELEVATIONS:
LOT 77, MAP OR PLAT ENTITLED "HIDDEN RIVER PHASE .ONE B", LIVING AREA: 71.90'
AS RECORDED IN PLAT BOOK ___, PAGES ___ THROUGH GARAGE AREA: N/A
OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. ELEVATIONS REFERENCED TO
CURVE I RADIUS ARC CHORD BEARING DELTA NATIONAL GEODETIC VERTICAL
C0 400,00' 97.09' 9&85' S 5T39'45" W 13'54'24" DATUM OF 1929. MEAN SEA
C35 51 5
400 ; . 0' 45754.23" W.
C38 06' 1 66.98' 1 N 45'54'23" E 0099'3366'1199" LEVEL= 00.00 FT.
LEGEND:
APPARENT FLOOD HAZARD ZONE: "X" COMMUNITY PANEL NO. 120230 0460 D EFFECTIVE DATE: 9/30/1992
(C)= CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, %= CENTERLINE, A/C= AIR CONDITIONER, B/C= BACK OF CURB, C/S=
CONCRETE SLAB, CH= CHORD, CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= COVERED, E/P= EDGE OF PAVEMENT, ESM'T= EASEMENT,
F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE, FIR= FOUND IRON ROD, FN&D= FOUND NAIL & DISK, FPP= FOUND PINCHED
PIPE, LFE= LOWEST FLOOR ELEVATION, MAS.= MASONRY, OR= OFFICIAL RECORD BOOK, PB= PLAT BOOK, PCP= PERMANENT CONTROL POINT, PRM= PERMANENT
REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & CAP No. 4493, SN&D= SET NAIL & DISK, TBM= TEMPORARY BENCHMARK,
U P= UTILITY POLE W F= WOOD FENCE. R = RADIAL
JOHN R.BEACH&ASSOCIATES,INC. Drawn By: SMS Square Feet: 8390,81 t LENNAR HOMES
itSURVEYORS AND MAPPERS Checked By:
II 911 WEST ST. PETERSBURG DRIVE
ONE OLDSMAR, FLORIDA 34677 JRB
WAY (813) 854-1276 FAX (813) 855-8370 Scale:
1"=30'
NOT VALID WITHOUT THE SIGNATURE AND Date of Survey:
THE ORIGINAL RAISED SEAL OF A FLORIDA PLOT PLAN 04/18/2018 RTM J N BEACH ATE
LICENSED SURVEYOR AND MAPPER FLORIDA G. LAND SURVEYOR No. 2984 LB 4493
Revisions:
24-26-21-0100-00000-0770 Pasco County Property Appraiser Page 1 of 1
Data Current as Of: Weekly Archive.- Monday, June 11, 2018
Parcel ID 24-26-21-0100-00000-0770 (Card: 001 of 001)
Classification 00-= Vacant Residential
Mailing Address _ Property Value
LENNAR HOMES LLC = Ag Land $0
4600 W CYPRESS ST STE 200 Land $30,652
TAMPA FL 33607-4099 Building $0
Physical Address Extra Features $0
3124 KRESTERBROOKE LANE
ZEPHYRHILLS, FL 33540
Just Value $30,652
Legal Description (First 4 Lines) Assessed (Non-School Amendment 1) $30,652
HIDDEN RIVER PHASE ONE B
PB 76 PG 077
LOT 77 Taxable Value $30,652
OR 9737 PG 3770
jurisdiction
City of Zephyrhills
Land Detail (Card: 001 of 001)
Line Use DescriptionZoning Units Type Price Condition Value
1 i0100 SFR MPUD 6,000.00 SF $4.75 1.00 $28,500
2 0100 SFR MPUD 2,391.00 SF $0.90 1.00 $2,152
_ Additional Land Information
T-
Acres 0.19 Tax Area 20ZH C de Residential Code I HDRVCPI
Building Information - Use 00 - Unimproved (Card: 001 of 001)
Unimproved Parcel 00 - Unimproved
Extra Features (Card: 001 of 001) _
Line Description Year e IUnits �IValue
No Extra Features
Sales History- See All 6 sales
Previous Owner: DUNE FL LAND I SUB LLC
Month/Year Book/Page IType DOR Code 'Conditi _o nt
06/2018 9737 / 3770 Warranty Deed 05��_Vacant Multi.Parcel Sale
09/2011 8606 / 3376 Warranty Deed 05 Vacant Multi-Parcel Sale
06/2010 8360 / 1872 Certificate of Title 12 Vacant $0
http://search.pascopa.com/parcel.aspx?parcel=2126240100000000770 6/15/2018
Jacqueline Boges
From: Nichole Spence (City of Zephyrhills Support)<support@zephyrhillsfl.zendesk.com>
Sent: Friday, July 13, 2018 6:27 PM
To: Jacqueline Boges
Subject: [FATHOM] Re: 3124 Kresterbrooke lane by#19806
##- Please type your reply above this line -##
Your request (#223449) has been updated. REPLY TO THIS EMAIL or click the link below:
https://zephyrhillsfl.zendesk.com/hc/requests/223449
....................................................................................................................................................................................................................................................................................................................................................................................
f
Nichole Spence (City of Zephyrhills Support )
Jul 13, 3:27 PM MST
Account # 2996739 has been created, service order to follow once mapping has been
completed.
Best Regards,
Nichole I FATHOM Support
.....................................................................................................................................................................................................................................................................................................................................................................................
Jacqueline Boges
I -- 1 = Jun 29, 8:25 AM MST
full service 3124 Kresterbrooke Lane by#19806 water, sewer, water meter
This email is a service from City of Zephyrhills Support .
1
Jacqueline Boges
From: Nichole Spence(City of Zephyrhills Support)<support@zephyrhillsfl.zendesk.com>
Sent: Saturday, July 14, 2018 11:49 AM
To: Jacqueline Boges
Subject: [FATHOM] Re: 3124 Kresterbrooke lane by#19806
##- Please type your reply above this line -##
Your request (#223449) has been solved. TO REOPEN THIS REQUEST, reply to this email or click the link below:
https://zephyrhillsfl.zendesk.com/hc/requests/223449
......................................................................................................................................................................................................................................................................................................................................................................................
Nichole Spence (City of Zephyrhills Support )
- Jul 14, 8:48 AM MST
Hello Jacqueline Boges,
The changes you requested have been completed.
I am marking this ticket as solved.
Best Regards,
Nichole I FATHOM Support
...................................................................................................................................................................................... .................................... ..................................................................................................................................
r i Nichole Spence (City of Zephyrhills Support )
`- Jul 13, 3:27 PM MST
Account # 2996739 has been created, service order to follow once mapping has been
completed.
Best Regards,
Nichole I FATHOM Support
......................................................................................................................................................................................................................................................................................................................................................................................
Jacqueline Boges
� - Jun 29, 8:25 AM MST
full service 3124 Kresterbrooke Lane by#1 9806 water, sewer, water meter
This email is a service from City of Zephyrhills Support .
i
PASCO COUNTY
DEVELOPMENT SERVICES:
8731 Citizens Drive Date:8/7/2019
COUNTY FLORIDA New Port'Richey,FL 34654
—.91.011 SPANS:14BI��]?EkES. 727-847--2411
NOT A PERMIT "
Receipt#: 1782475
FEE DESCRIPTION ACCOUNT CODE UNITS INVOICE# FEE AMOUNT PAID. RECEIPT# DATE
Impact Fee Residential Solid 24503100-329010 25.50 1372039 $25-.50 $25.50 1782475 8/7/18
Waste Single Family
3124 KkESTERBROOKE LANE.
TOTALS: $96.60 $25.60
Receipt Paid By: Check CC Auth# Cashier ID ;Workstation Receipt Date AMt Paid
1182475 Check 01029754 554 BCCCP58W 08/07/2018 $25.50
Total Payments: $25.60
Pavor Address Phone
hone
LENNAR HOMES.LI-C
Comments:
3124 KIRESTERIBROOKE LANE
While you will be paying your bill with Pasco County 66viloptrienfServices,the full amount of the credit card or e-checkfeis,NUrshownabove,is co lecttic!by
First Billing payment services.
'02895956 'Lennar Homes,LLC JPMorgaq Chase Bank'N';A. STUB CHECK NO. 302975M
Iwo]&
900000.1010.114 1 of I DATE 08/02/18
-
Co.,0 AMBER DATE. PAYMENTADVICE CROSS DISCOUNT —NET
15174 151-74710077.401435 072418 15174720077 401435 01435 $25.50 10.00 $25.50
t
ODLE
197107 Pasco County 13OCC 7530 Little Road
Port Richey FL 33553-0000 s25.50 $0.00 K-50
MyRep(5ftstreports#PASCOPROD/PASC6/ReceiptPOS—V6.rpt 8/7/W18 Page 1 of 1
Jacqueline Boges
From: City of Zephyrhills Support<support@zephyrhillsfl.zendesk.com>
Sent: Friday, June 29, 2018 11:25 AM
To: Jacqueline Boges
Subject: [Request received] 3124 Kresterbrooke lane by#19806
##- Please type your reply above this line -##
Hello Jacqueline Boges,
We are working to resolve your request promptly and will keep you updated. One of our Support Analysts will keep
you updated on the progress of your request.
Best Regards,
FATHOM Support Team
TO ADD ADDITIONAL COMMENTS, reply to this email or click the link below:
https://zephyrhillsfl.zendesk.com/hc/requests/223449
.......................................................................................................................................................................................................................................................................................................................................................................................
Jacqueline Boges
Jun 29, 8:25 AM MST
full service 3124 Kresterbrooke Lane by#19806 water, sewer., water meter
This email is a service from City of Zephyrhills Support .
1
2018103054
r£cpt:l$66851 ITeC0.00.00
PS:
06/ 0.00
19/2018 C. F. , Dpty Clerk
�pULR S.0't3E m IL,Ph.D.PRSG4 GLERKO G1MPTROLLER
�GOR SK 1 � AG
Permit No. Parcel ID No 24-26-21-0100-00000-0770
NOTICE OF COMMENCEMENT
State of Florida County of Pasco
THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 713,Florida Statutes,
the following information is provided in this Notice of Commencement:
1. Description of Property: Legal HIDDEN RIVER PHASE ONE B PB 76 PG 77 LOT 77
Street Address: 3124 Kresterbrooke Lane Zephryhills FL 33541
2. General Description of Improvement Single Family Residence J Pool J Screen Enclosure J Fence
3. Owner Information: Lennar Homes,LLC.
-Name
4600 W Cypress St. Ste 200 Tampa FL. 33607
Address City State
Interest in Property:
Name of Fee Simple Titleholder: N/A
(if other than owner)
Address City State
4. Contractor: Lennar Homes, LLC
Name
4600 W Cypress St, Ste 200 Tampa FL, 33607
Address City. State
Contractor's Telephone No.: 813,574.5700
5. Surety: .' NIA
Name
Address City State
Amount of Bond: $ Telephone No.:
6. Lender: N/A
Name
Address City State
Lender's Telephone No.:
7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by
Section 713.13(1)(a)(7),Florida Statutes:
Lennar Homes LLC
Name
4600 W Cypress St,Ste 200 Tampa FL, 33607
Address City State
Telephone Number of Designated Person: 813.574.5700
8. In addition to himself,the owner designates N/A of
P to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statutes.
Telephone Number-of Person or Entity Designated by Owner:
• 9. Expiration date of Notice of Commencement is one year from the date of recording unless a different date is specified:
WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT
ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713,13, FLORIDA STATUTES, AND CAN
RESULT,IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE
RECORDED AND POSTED ON.THE JOB SITE BEFORE THE FIRST INSPECTION: IF YOU INTEND TO OBTAIN FINANCING,CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT.
STATE OF FLORIDA
COUNTY OF PINELLAS
Signature of Owner or Owner's Authorized Officer/Director/Partner/Manager
Vice President
Signatory's Title/Office
The foregoing instrument was acknowledged before me this 30 day of March -by.
Steve Robert Smith as Vice President (type of authority,e.g.,officer,trustee,attorney in.fact)for
Lennar Homes LLC (name of parry on o who ' strument was executed).
Personally Known N OR Produced Identification❑ Notary Signatur
Type of Identification Produced Name(Print) 6 a eran
Verification pursuant to Section 92.525,Florida Statutes. Under penalties of perjury,I declare that 1 have read the foregoing and that the facts statedin
it are true to the best of my knowledge and belief.
ElIS8A1Ns,HOLLERAN Signature of Natural Person Signing Above
mntl�slon FF985837
Ex Iras June 6;2424
wpdataibcsibcs.form,, Mo. do4dwThnr7rorRalnlMunnat00.3wnlo
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: 2575B1 sf ADS Carrier Builder Name: Lennar Homes
Street: 3124 Kresterbrooke Lane Permit office: Cit�,p kZ phyrhjlls
City,State,Zip: FL, Permit Number: U
Owner Lennar Homes Jurisdiction:611 0
Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(2613.1 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1264.00 ftz
b.Concrete Block-Int Insul,Exterior R=4.1 996.67 ft2
3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 352.44 ftZ
4. Number of Bedrooms 4 d.N/A R= ft2
5. Is this a worst case? Yes 10.Ceiling Types (1489.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1489.00 ft2
6. Conditioned floor area above grade(ft2) 2582 b.N/A R= ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ft2
11.Ducts R ft2
7. Windows(175.6 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 218.6
a. U-Factor: Dbl,U=0.54 71.25 ft2 b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 298.2
SHGC: SHGC=0.31
b. U-Factor: Dbl,U=0.56 71.00 ft2 12.Cooling systems kBtulhr Efficiency
SHGC: SHGC=0.28 a.Central Unit 18.0 SEER:15.00
b.Central Unit 24.0 SEER:15.50
c. U-Factor: Dbl,U=0.56 33.33 ft2
SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a.Electric Heat Pump 17.7 HSPF:8.50
SHGC: b.Electric Heat Pump 24.0 HSPF:9.00
Area Weighted Average Overhang Depth: 1.190 ft.
Area Weighted Average SHGC: 0.300 14.Hot water systems
ft.) Insulation Area a.Electric Cap:40 gallons
8. Floor Types (2582.0 sqft.) EF:0.950
a.Slab-On-Grade Edge Insulation R=0.0 1093.00 ft2 b. Conservation features
b.Floor Over Other Space R=0.0 1056.00 ft2 None
c.other(see details) R= 433.00 ft2 15.Credits Pstat
Total Proposed Modified Loads: 74.84 PASS
Glass/Floor Area: 0.068
Total Baseline Loads: 74.78
hereby certify that the plans and specifications covered by Review of the plans and � TIiE SxT
this calculation are in compliance With the Florida Energy specifications covered by this Off;
Code. calculation;indicates compliance �.
r with the�Florida Energy Code. F, rnrr •;= •,':•�' „ O
Ve >upic Before construction is completed
PREPARED BY: D(/I r� , -•-
DATE: this building will be inspected for
compliance with Section 553.908
I herebycertify that this building,as designed,is in compliance Florida Statutes.
fY 9, 9 P '�_
with the Florida Energy Code. MAY 0 3 2010 COD W '
OWNER/AGENT: BUILDING OFFICI L:
DATE: DATE:
- Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.050 Qn for whole house.
5/1/2018 8:59 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5
T r
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: 2575B1 sf ADS Carrier Builder Name: Lennar Homes
Street: 3124 Kresterbrooke Lane Permit Office: City of Zephyrhills
City,State,Zip: FL, Permit Number:
Owner. Lennar Homes Jurisdiction:611600
Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(2613.1 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1264.00 ft2
b.Concrete Block-Int Insul,Exterior R=4.1 996.67 ft2
3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 352.44 ft2
4. Number of Bedrooms 4 d.N/A R= ft2
5. Is this a worst case? Yes 10.Ceiling Types (1489.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1489.00 ft2
6. Conditioned floor area above grade(ft2) 2582 b.N/A R= ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ft2
11.Ducts R ft2
7. Windows(175.6 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 218.6
a. U-Factor: Dbl,U=0.54 71.25 ft2 b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 298.2
SHGC: SHGC=0.31
b. U-Factor: Dbl,U=0.56 71.00 ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.28 a.Central Unit 18.0 SEER:15.00
b.Central Unit 24.0 SEER:15.50
c. U-Factor: Dbl,U=0.56 33.33 ft2
SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency
-d. U-Factor: N/A ft2 a.Electric Heat Pump 17.7 HSPF:8.50
SHGC: b.Electric Heat Pump 24.0 HSPF:9.00
Area Weighted Average Overhang Depth: 1.190 ft.
Area Weighted Average SHGC: 0.300 14.Hot water systems
8. Floor Types (2582.0 sqft.) Insulation Area a.Electric Cap:40 gallonsEF:0.950
a.Slab-On-Grade Edge Insulation R=0.0 1093.00 ft2 b. Conservation features
b.Floor Over Other Space R=0.0 1056.00 ft2 None
c.other(see details) R= 433.00 ft2 15.Credits Pstat
Glass/Floor Area: 0.068 Total Proposed Modified Loads: 74.84 PASS
Total Baseline Loads: 74.78
hereby certify that the plans and specifications covered by Review of the plahs and �ylc C S ,g
this calculation,are in compliance with the Florida Energy specifications covered by this Off,
Code. calculation indicates compliance A
Mich
with the Florida Energy Code. ti'rtrrii •;? �, O
PREPARED BY: D-aye ff rch Before construction is completed
DATE: this building will be inspected for
I -
compliance with Section 553.908 * = ,
I herebycertify that this building,as designed, is in compliance
Florida Statutes.
fY 9� 9 P .._ _
with the Florida Energy Code. C�D`W'g' =
OWNER/AGENT: MAY O 3 2018 BUILDING OFFICI I
DATE: DATE:
- Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2).
I. Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.050 Qn for whole house.
5/1/2018 8:59 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: 2575B1 sf ADS Carrier Builder Name: Lennar Homes
Street: 3124 Kresterbrooke Lane PermiE Office: City of Zephyrhills
City,State,Zip: FL, Permit Number:
Owner. Lennar Homes Jurisdiction:611600
Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(2613.1 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1264.00 ft2
b.Concrete Block-Int Insul,Exterior R=4.1 996.67 ft2
3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 352.44 ft2
4. Number of Bedrooms 4 d.N/A R= ft2
5. Is this a worst case? Yes 10.Ceiling Types (1489.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1489.00 ft2
6. Conditioned floor area above grade(ft2) 2582 b.N/A R= ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ft2
11.Ducts R ft2
7. Windows(175.6 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 218.6
a. U-Factor: Dbl,U=0.54 71.25 ft2 b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 298.2
SHGC: SHGC=0.31
b. U-Factor: Dbl,U=0.56 71.00 ft2 12•Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.28 a.Central Unit 18.0 SEER:15.00
b.Central Unit 24.0 SEER:15.50
c. U-Factor: Dbl,U=0.56 33.33 ft2
SHGC: SHGC=0.32 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a.Electric Heat Pump 17.7 HSPF:8.50
SHGC: b.Electric Heat Pump 24.0 HSPF:9.00
Area Weighted Average Overhang Depth: 1.190 ft.
Area Weighted Average SHGC: 0.300 14.Hot water systems
S. Floor Types (2582.0 sqft.) Insulation Area a.Electric Cap:40 gallonsEF:0.950
a.Slab-On-Grade Edge Insulation R=0.0 1093.00 ft2 b. Conservation features
b.Floor Over Other Space R=0.0 1056.00 ft2 None
c.other(see details) R= 433.00 ft2 15.Credits Pstat
Glass/Floor Area: 0.068 Total Proposed Modified Loads: 74.84 PASS
Total Baseline Loads: 74.78
I hereby certify that the plans and specifications covered by Review of the plans andT_I .ST�g1,
this calculation are in,compliance with the Florida Energy specifications covered by this 0�
Code. calculation indicates compliance
with the Florida Energy Code. �+'hrri. :�% • � .� �ti ,O
PREPARED BY: ,/have Aupich Before construction is completed
DATE: this building will be inspected for
compliance with Section 553.908
I hereby certify that this building,as signed, is in compliance Florida Statutes. :S
with the Florida Energy Code.
MAY 0 3 2010
OWNER/AGENT: BUILDING OFFICIAL:
DATE: LK DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.050 Qn for whole house.
5/1/2018 8:59 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 5
FORM R405-2017
PROJECT
Title: 2575B1 sf ADS Carrier Bedrooms: 4 Address Type: Street Address
Building Type: User Conditioned Area: 2582 Lot#
Owner Name: Lennar Homes Total Stories: 2 Block/Subdivision:
#of Units: 1 Worst Case: Yes PlatBook:
Builder Name: Lennar Homes Rotate Angle: 90 Street:
Permit Office: Cross Ventilation: County: Pasco
Jurisdiction: Whole House Fan: City,State,Zip: ,
Family Type: Single-family FL,
New/Existing: New(From Plans)
Comment: FBC 2017
CLIMATE
Design Temp Int Design Temp Heating Design Daily Temp
Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,Tampa FL TAMPA INTERNATI 39 91 70 75 645.5 54 Medium
BLOCKS
Number Name Area Volume
1 Block1 1093 9399.8
2 Block2 1489 11912
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
1 1 st Floor 1093 9399.8 Yes 0 1 Yes Yes Yes
2 2nd Floor 1489 11912 No 5 4 1 Yes Yes Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio 1st Floor 102 ft 0 1093 ft2 — 0.3 0 0.7
2 Raised Floor 2nd Floor -e- — 13 ft2 11 0 0 1
3 Floor over Garage 2nd Floor -__- 420 ft2 11 0.2 0 0.8
4 Floor Over Other Space 2nd Floor 1056 ft2 0 0.2 0 0.8
ROOF
Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
1 Hip Composition shingles 1613 ft2 0 ft2 Medium 0.85 No 0.9 No 0 22.6
ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Vented 300 1489 ft2 N N
5/1/2018 8:59 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5
FORM R405-2017
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Vented) 2nd Floor 30 Blown 1489 ft2 0.11 Wood
WALLS
Adjacent Space Cavity Width Height Sheathing Framing Solar Below
1 N=>E Exterior Concrete Block-Int Insul 1st Floor 4.0999 19 8 8 164.7 ft2 0 0.600000 0
2 E=>S Exterior Concrete Block-Int Insul 1st Floor 4.0999 38 8 8 329.3 ft2 0 0.600000 0
3 S=>W Exterior Concrete Block-Int Insul 1 st Floor 4.0999 34 8 8 294.7 ft2 0 0.600000 0
4 W=>N Exterior Concrete Block-Int Insul 1st Floor 4.0999 18 8 8 156.0 ft2 0 0.600000 0
5 N=>E Garage Frame-Wood 1 st Floor 11 20 8 8 173.3 ft2 0 0.01 0
6 W=>N Garage Frame-Wood 1 st Floor 11 20 8 8 8 179.1 ft2 0 0.01 0
7 N=>E Exterior Frame-Wood 2nd Floor 11 40 8 320.0 ft2 0 0.600000 0
8 E=>S Exterior Frame-Wood 2nd Floor 11 39 8 312.0 ft2 0 0.6 0
9 S=>W Exterior Frame-Wood 2nd Floor 11 40 8 320.0 ft2 0 0.600000 0
10 W=>N Exterior Frame-Wood 2nd Floor 11 39 8 0 312.0 ft2 0 0.600000 0
11 S=>W Exterior Concrete Block-Int Insul 1st Floor 4.0999 6 8 8 52.0 ft2 0 0.600000 0
DOORS
# Ornt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 N=>E Insulated 1st Floor None .2 3 6 8 20 ft2
2 N=>E Wood 1st Floor None .4 2 8 6 8 17.8 ft2
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
Wall Overhang
V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening
3 S=>W 11 Metal Law-E Double Yes 0.56 0.32 N 33.3 ft2 2 ft 0 in 0 ft 6 in Drapes/blinds None
4 S=>W 3 Metal Low-E Double Yes 0.54 0.31 N 9.3 ft2 1 ft 0 in 10 ft 0 in Drapes/blinds None
5 N=>E 7 Metal Low-E Double Yes 0.56 0.28 N 16.0 ft2 1 ft 0 in 4 ft 0 in Drapes/blinds None
6 S=>W 9 Metal Low-E Double Yes 0.54 0.31 N 23.0 ft2 1 ft 0 in 0 ft 6 in Drapes/blinds None
7 W=>N 10 Metal Low-E Double Yes 0.54 0.31 N 16.0 ft2 1 ft 0 in 0 ft 6 in Drapes/blinds None
8 N=>E 7: Metal Low-E Double Yes 0.56 0.28 N 32.0 ft2 1 ft 0 in 0 ft 6 in Drapes/blinds None
9 S=>W 3, Metal Low-E Double Yes 0.54 0.31 N 23.0 ft2 1 ft 0 in 10 ft 0 in Drapes/blinds None
10 N=>E 1 Metal Low-E Double Yes 0.56 0.28 N 23.0 ft2 1 ft 0 in 1 ft 4 in Drapes/blinds None
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 420 ft2 420 ft2 41 ft 8.6 ft 1
5/1/2018 8:59 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5
FORM R405-2017
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000367 2486.4 136.5 256.71 .339 7
HEATING SYSTEM
# System Type. Subtype Efficiency Capacity Block Ducts
1 Electric Heat Pump/ Split HSPF:8.5 17.7 kBtu/hr 1 sys#1
2 Electric Heat Pump/ Split HSPF:9 24 kBtu/hr 2 sys#2
COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit/ Split SEER: 15 18 kBtu/hr 540 cfm 0.85 1 sys#1
2 Central Unit/ Split SEER: 15.5 24 kBtu/hr 720 cfm 0.85 2 sys#2
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.95 40 gal 70 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None ft2
DUCTS
/ —Supply— —Return— Air CFM 25 CFM25 HVAC#
V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 218.6 ft 2nd Floor 54.65 ft Proposed Qn 2nd Floor —cfm 54.7 cfm 0.05 0.60 1 1
2 Attic 6 298.2 ft 2nd Floor 74.55 ft Proposed Qn 2nd Floor —cfm 74.5 cfm 0.05 0.60 2 2
TEMPERATURES
Programable Thermostat:Y Ceiling Fans:
CoolingJan Feb Mar Apr May Jun Jul Auge Oct Nov! ,' Dec
Heatin Jan Feb ki
Mar Apr I
May Jun Jul Aug Se Oct XNov Dec
'Ventin Jan Feb Mar [X]Apr 'Ma Jun Jul Augr1sep [X Oct X Nov Dec
5/1/2018 8:59 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 5
,FORM R405-2017
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
5/1/2018 8:59 AM EnergyGauge@ USA-FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5
FORM R405-2017
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 100
The lower the EnergyPerformance Index,the more efficient the home.
„ FL,
1. New construction or existing New(From Plans) 9. Wall Types Insulation Area
2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1264.00 ftz
b.Concrete Block-Int Insul,Exterior R=4.1 996.67 ftz
3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 352.44 ftz
4. Number of Bedrooms 4 d.N/A R= ftz
5. Is this a worst case? Yes 10.Ceiling Types Insulation Area
a.Under Attic(Vented) R=30.0 1489.00 ftz
6. Conditioned floor area(ftz) 2582 b.N/A R= ftz
7. Windows" Description Area c.N/A R= ftz
a. U-Factor: Dbl,U=0.54 71.25 ftz 11.Ducts R ftz
a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 218.6
SHGC: SHGC=0.31 b.Sup: Attic,Ret:2nd Floor,AH:2nd Floor 6 298.2
b. U-Factor: Dbl,U=0.56 71.00 ftz
SHGC: SHGC=0.28 12.Cooling systems kBtu/hr Efficiency
c. U-Factor: Dbl,U=0.56 33.33 ftz a.Central Unit 18.0 SEER:15.00
SHGC: SHGC=0.32 b.Central Unit 24.0 SEER:15.50
d. U-Factor: N/A ftz 13.Heating systems kBtu/hr Efficiency
SHGC: a.Electric Heat Pump 17.7 HSPF:8.50
Area Weighted Average Overhang Depth: 1.190 ft. b.Electric Heat Pump 24.0 HSPF:9.00
Area Weighted Average SHGC: 0.300
8. Floor Types Insulation Area 14.Hot water systems
a.Electric Cap:40 gallons
a.Slab-On-Grade Edge Insulation R=0.0 1093.00 ftz EF:0.95
b.Floor Over Other Space R=0.0 1056.00 ftz
c.other(see details) R= 433.00 ftz b. Conservation features
None
15:Credits Pstat
certify that this home has complied with the Florida Energy Efficiency Code for BuildingIibSrg
Construction through the above energy saving features which will be installed (or exceeded) •O ' " _ _. o
in this home before final inspection. Otherwise, a new EPL Display Card will be,completed y�",,;;''%'
based on installed Code compliant features.
Builder Signature: Date: 05/61/18 M. �
Address of New Home: 3124 Kr sterbrooke Lane City/FL Zip: Ze h rhills,
F Y FL 33540°
*Note: This is not a Building Energy Rating. If.your Index is below 70, your home may qualify for energy efficient
mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at
techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of
certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building
Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
5/1/2018 9:00 AM EnergyGauge®USA-FlaRes2017 -Section R405.4.1 Compliant Software Page 1 of 1
Buildin Anal $I$ Job: 2575B1 sf ADS Carrier
g Y Date: 511/2018
lower floor By: Dave
Bayonet Plumbing Heating and Air
Proiect I nformation
For: Lennar Homes
Design Conditions
Location: Indoor: Heating Cooling
Tampa International AP, FL, US Indoor temperature(OF) 70 75
Elevation: 10 ft Design TD (OF) 39 16
Latitude: 28°N Relative humidity(%) 50 50
Outdoor: Heating Cooling Moisture difference(gr/lb) 34.7 54.7
Dry bulb(OF) 31 91 Infiltration:
Daily range(OF) - 14 ( L ) Method Simplified
Wet bulb(°F) - 77 Construction quality Semi-tight
Wind speed (mph) 15.0 7.5 Fireplaces 0
•
Component Btuh/ft2 Btuh % of load
Walls 5.5 5191 31.9 gas
Glazing 30.2 2683 16.5 nfiltraton
Doors 21.2 432 2.7 Walls
Ceilings 1.7 60 0.4
Floors 4.1 4478 27.5
Infiltration 1.9 2039 12.5
Ducts 1400 8.6
Piping 0 0 Floors
Humidification 0 0 Glazing
Ventilation 0 0 Doors Other
Adjustments 0
Total 16284 100.0
Component Btuh/ft2 Btuh % of load
Walls 2.8 2641 23.2 Internal Gains
Glazing 56.3 5004 44.1 walls
Doors 16.6 338 3.0
Ceilings 2.0 67 0.6 Ducts
Floors 0 0 0
Infiltration 0.4 454 4.0
Ducts 1655 14.6 Infiltration
Ventilation 0 0 Other
Internal gains 1200 10.6 Doors
Blower 0 0
Adjustments 0 Glazing
Total 11360 100.0
Latent Cooling Load= 1237 Btuh
Overall U-value= 0.150 Btuh/ft2-°F
Data entries checked.
t -�- wrGgF�tsoft® 2018-May-01 13:59:34
^�^•k ^� Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1
...ent\2575B sf ADS template 1.5-2 ton Carrier.rup Calc=MJ8 Front Door faces:NW
Buildin Anal SIS Job: 2575B1 sf ADS Carrier
g Y Date: 5/1/2018
upper floor By: Dave
Bayonet Plumbing Heating and Air
Project Information
For: Lennar Homes
Design Conditions
Location: Indoor: Heating Cooling
Tampa International AP, FL, US Indoor temperature(°F) 70 75
Elevation: 10 ft Design TD (°F) 39 16
Latitude: 280N Relative humidity (%) 50 50
Outdoor: Heating Cooling Moisture difference(gr/lb) 34.7 54.7
Dry bulb(°F) 31 91 Infiltration:
Daily range(°F) - 14 ( L ) Method Simplified
Wet bulb(°F) - 77 Construction quality Semi-tight
Wind speed (mph) 15.0 7.5 Fireplaces 0
Component Btuh/ftz Btuh % of load
Walls 3.8 4204 32.8 °as
Glazing 30.2 2608 20.3
Doors 0 0 0 wall
Ceilings 1.3 1868 14.6 nfiltrafion
Floors 0 0 0
Infiltration 1.9 2299 17.9
Ducts 1846 14.4
Piping 0 0
Humidification 0 0 Ceilings
Ventilation 0 0 Glazing
Adjustments 0
Total 12825 100.0
Component Btuh/ft2 Btuh % of load
Walls 2.7' 3035 16.6 Wall
Glazing 53.0 4581 25.1
Doors 0 0 0 Internal Gains
Ceilings 1.7 2583 14.2
Floors 0 0 0 i._..
Infiltration 0.4 512 2.8 i
Ducts 2137 11.7
Ventilation 0 0 Glazing
Internal gains 5385 29.5
Blower 0 0 Ducts
Adjustments 0 Infiltration
Total 1 1182331 100.0 Ceilings
Latent Cooling Load= 3341 Btuh
Overall U-value= 0.083 Btuh/ft2-°F
Data entries checked.
1 -F- =ightsoft- 2018-May-01 13:59:34
^w^•tom Right-Suited Universal 2018 18.0.16 RSU05714 Page 2
ACCK ..ent\25756 sf ADS template 1.5-2 ton Carrier.rup Calc=MJ8 Front Door faces:NW
Project Summary Job: 2575B1 sf ADS Carrier
Date: 5/112018
lower floor By: Dave
Bayonet Plumbing Heating and Air
Project Information
For: Lennar Homes
Notes:
Desicin Information
Weather: Tampa International AP, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 31 OF Outside db 91 OF
Inside db 70 OF Inside db 75 OF
Design TD 39 OF Design TD 16 OF
Daily range L
Relative humidity 50 %
Moisture difference 55 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 14883 Btuh Structure 9705 Btuh
Ducts 1400 Btuh Ducts 1655 Btuh
Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh
none
(none)
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 16284 Btuh Use manufacturer's data y
Rate/swing multiplier 1.00
Infiltration Equipment sensible load 11360 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Semi-tight
Fireplaces 0 Structure 942 Btuh
Ducts 294 Btuh
Central vent(0 cfm) 0 Btuh
Heating Cooling (none)
Area(ftz 1093 1093 Equipment latent load 1237 Btuh
Volume(ft3) 9654 9654
Air changes/hour 0.29 0.16 1 Equipment Total Load (Sen+Lat) 12596 Btuh
Equiv.AVF (cfm) 47 25 Req. total capacity at 0.85 SHR 1.1 ton
Heating Equipment Summary Cooling Equipment Summary
Make Carrier Make Carrier
Trade Trade
Model 25HBC518AO0300 Cond 25HBC518AO0300
AHRI ref 9154643 Coil FB4CNP025L
AHRI ref 9154643
Efficiency 8.5 HSPF Efficiency 12.5 EER, 15 SEER
Heating,input Sensible cooling 15300 Btuh
Heating output 17700 Btuh @ 47°F Latent cooling 2700 Btuh
Temperature rise 27 OF Total cooling 18000 Btuh
Actual air flow 600 cfm Actual air flow 600 cfm
Air flow factor 0.037 cfm/Btuh Air flow factor 0.053 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.90
Capacity balance point= 30 OF
Backup:
Input=4 kW, Output= 15295 Btuh, 100 AFUE
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
-�- wrightsoft� 2018-May-01 13:59:34
Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1
ACC` ...ent\2575B sf ADS template 1.5-2 ton Carrier.rup Calc=MJ8 Front Door faces:NW
Pro ect Summa Job: 2575B1 sf ADS Carrier
1 ry Date: 5/1/2018
upper floor By: Dave
Bayonet Plumbing Heating and Air
Proiect Information
For: Lennar Homes
Notes:
Desicin Information
Weather: Tampa International AP, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 31 OF Outside db 91 OF
Inside db 70 OF Inside db 75 OF
Design TD 39 OF Design TD 16 OF
Daily range L
Relative humidity 50 %
Moisture difference 55 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 10978 Btuh Structure 16096 Btuh
Ducts 1846 Btuh Ducts 2137 Btuh
Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh
(none) (none)
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 12825 Btuh Use manufacturer's data y
Rate/swing multiplier 1.00
Infiltration Equipment sensible load 18233 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Semi-tight
Fireplaces 0 Structure 2962 Btuh
Ducts 379 Btuh
Central vent(0 cfm) 0 Btuh
Heating Cooling (none)
Area(ftz) 1489 1489 Equipment latent load 3341 Btuh
Volume(ft') 11912 11912
Air changes/hour 0.27 0.14 Equipment Total Load (Sen+Lat) 21574 Btuh
Equiv.AVF(cfm) 53 29 Req. total capacity at 0.85 SHR 1.8 ton
Heating Equipment Summary Cooling Equipment Summary
Make Carrier' Make Carrier
Trade Trade
Model 25HBC524AO0300 Cond 25HBC524AO0300
AHRI.ref 9154943 Coil FB4CNP025L
AHRI ref 9154943
Efficiency 9 HSPF Efficiency 12.5 EER, 15.5 SEER
Heating input Sensible cooling 20400 Btuh
Heating output 24000 Btuh @ 470F Latent cooling 3600 Btuh
Temperature rise 27 OF Total cooling 24000 Btuh
Actual air flow 800 cfm Actual air flow 800 cfm
Air flow factor 0.062 cfm/Btuh Air flow factor 0.044 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.85
Capacity balance point= 16 OF
Backup:
Input= 3 kW, Output= 11787 Btuh, 100 AFUE
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
-Fk- wrightsoft® 2018-May-01 13:59:34
•�^ - p Right-Suite®Universal 2018 18.0.16 RSU05714 Page 2
ACCK ..ent\2575B sf ADS template 1.5-2 ton Carrier.rup Calc=MJ8 Front Door faces:NW
Manual S Compliance Report Job: 2575B1 sf ADS Carrier
Date: 5/1/2018
lower floor By: Dave
Bayonet Plumbing Heating and Air
Project Information
For: Lennar Homes
Cooling Equipment
Design Conditions
Outdoor design DB: 91.3°F Sensible gain: 11360 Btuh Entering coil DB: 75.8°F
Outdoor design WB: 77.3°F Latent gain: 1237 Btuh Entering coil WB: 62.9°F
Indoor design DB: 75.0°F Total gain: 12596 Btuh
Indoor RH: 50% Estimated airflow: 600 cfm
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: SplitASHP
Manufacturer: Carrier Model: 25HBC518A00300+FB4CNP025L
Actual airflow: 600 cfm
Sensible capacity: 15300 Btuh 135% of load
Latent capacity: 2700 Btuh 218% of load
Total capacity: 18000 Btuh 143% of load SHR: 85%
Heating Equipment
Design Conditions
Outdoor design DB: 30.8°F Heat loss: 16284 Btuh Entering coil DB: 69.6°F
Indoor design DB: 70.0°F
I
i
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: SplitASHP '
Manufacturer: Carrier Model: 25HBC518A00300+FB4CNP025L
Actual airflow: 600 cfm
Output capacity: 13453 Btuh 83% of load Capacity balance: 30 OF
Supplemental heat required: 2831 Btuh Economic balance: -99 OF
Backup equipment type: Elec strip
Manufacturer: Model:
Actual airflow: 600 cfm
Output capacity: 4.5 kW 94% of load Temp. rise: 50 OF
Meets all requirements of ACCA Manual S.
Wrightsoft® 2018-May-01 13:59:34
Au -/—ww•-",� Right-Suite®Universal 2018 18.0.16 RSU05714
Page 1
...ent\2575B sf ADS template 1.5-2 ton Carrier.rup Calc=MJ8 Front Door faces:NW
Manual S Compliance Report Job: 2575B1 sf ADS Carrier
Date: 5/1/2018
upper floor By: Dave
Bayonet Plumbing Heating and Air
Project Information
For: Lennar Homes
Cooling Equipment
Design Conditions
Outdoor design DB: 91.3°F Sensible gain: 18233 Btuh Entering coil DB: 75.6°F
Outdoor design WB: 77.3°F Latent gain: 3341 Btuh Entering coil WB: 62.8°F
Indoor design DB: 75.0°F Total gain: 21574 Btuh
Indoor RH: 50% Estimated airflow: 800 cfm
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: SplitASHP
Manufacturer: Carrier Model: 25HBC524A00300+FB4CNP025L
Actual airflow: 800 cfm
Sensible capacity: 20400 Btuh 112% of load
Latent capacity: 3600 Btuh 108% of load
Total capacity: 24000 Btuh 111% of load SHR: 85%
Heating Equipment
Design Conditions
Outdoor design DB: 30.8°F Heat loss: 12825 Btuh Entering coil DB: 69.6°F
Indoor design DB: 70.0°F
I
I
Manufacturer's Performance Data at Actual Design Conditions
Equipment type:' SplitASHP
Manufacturer: Carrier Model: 25HBC524A00300+FB4CNP025L
Actual airflow: 800 cfm
Output capacity: 24000 Btuh 187% of load Capacity balance: 16 OF
Supplemental heat required: 0 Btuh Economic balance: -99 OF
Backup equipment type: Elec strip
Manufacturer: Model:
Actual airflow: 800 cfm
Output capacity: 3.5 kW 92% of load Temp. rise: 50 OF
Meets all requirements of ACCA Manual S.
1 -Fk Wrightsoft® M18-May-o1 13:59:34
Right-Suite®Universal 2018 18.0.16 RSU05714 Page 2
...ent\2575B sf ADS template 1.5-2 ton Carrier.rup Calc=MJ8 Front Door faces:NW
} 5335 - 8TH STREET
(813)780-0020
CERTIFICATE OF OCCUPANCY
Address: 3124 KRESTERBROOKE LANE Owner: LENNAR HOMES LLC
ZEPHYRHILLS, FL. 4600 W CYPRESS ST STE 200
Subdiv: HIDDEN RIVER TAMPA FL 33607-4099
Parcel: 24-26-21-0100-00000-0770 Work Type: 101-NEW CONST/SFR
Construction Type: NOT APPLICABLE ❑ Sprinklers
Use Classification: NOT APPLICABLE
Permit Number: 19806
Date: 10/30/2018
n,,--a.e,L-e
(��-
ISSUE Y: BUILDI OFFICIAL :
WATER MUST BE CHANGED OVER WITHIN 10 DAYS OF ISSUANCE
GARBAGE DEPOSIT MUST BE APPLIED FOR PRIOR TO ISSUANCE