HomeMy WebLinkAbout18-19807 CITY OF ZEPHYRHILLS
5335-8TH STREET
(813)780-0020 19807
BUILDING PERMIT SINGLE FAMILY RESIDENTIAL
PERMIT INFORMATION LOCATION INFORMATION
Permit#:19807 Issued: 6/25/2018 Address: 3051 MOULDEN HOLLOW DR
Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL.
Class of Work: 101-NEW CONST/SFR Township: Range:
Proposed Use: NOT APPLICABLE Lot(s): Block: Section:
Sq. Feet: Est. Value: Book: Page:
Cost: 267,656.40 Total Fees: 17,872.97 Subdivision: HIDDEN RIVER
Amount Paid: 17,872.97 Date Paid: 6/25/2018 Parcel Number: 24-26-21-0100-00000-0460
CONTRACTOR INFORMATION OWNER INFORMATION
Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC
Addr: 4600 W. CYPRESS ST STE 200 Address: 4600 W CYPRESS ST STE 200
TAMPA, FL. 33607 TAMPA FL 33607-4099
Phone: (813)574-5743 Lic: Phone: 813-574-5700
Work Desc: CONSTRUCT SINGLE FAMILY 2,376 SQ FT
APPLICATION-FEES
BUILDING FEE 1,482.60 ELECTRICAL FEE 310.50 PLUMBING FEE 207.00
MECHANICAL FEE 144.90 SEWER CONNECTION RESIDEW 2,090.00 WATER CONNECTION RESIDENI 1,010.00
WATER METER RES 3/4" 473.78 PARK FEES SF 769.56 POLICE IMPACT FEE 254.00
FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 SCHOOL-SFR NEW 1% 71.28
SCHOOL IMPACT FEE NEW 7,128.00 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32
( 0 l
17)
Inspections Rehy,red
FOOTER 2ND ROUGH PLUMB Misc INSULATION CEILING
FOOTER BOND DUCTS INSULATED SEWER MISC.
ROUGH ELECTRIC LINTEL MISC MISC.
1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC.
DUCTS INSTALLED WATER MISC DRIVEWAY
PRE-SLAB SHEATHING MISC. MISC.
CONSTRUCTION POLE FRAME MISC. MISC.
REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES:
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing, consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance
with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
L
CON CTORS SIGNATURE PERMIT OFFI
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIOlf
CALL FOR INSPECTION - B HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
Jacqueline Boges
From: City of Zephyrhills Support<support@zephyrhillsfl.zendesk.com>
Sent: Friday, June 29, 2018 8:42 AM
To: Jacqueline Boges
Subject: [Request received] 3051 Moulden Hollow dr bp#1 9807
##- Please type your reply above this line -##
Hello Jacqueline Boges,
We are working to resolve your request promptly and will keep you updated. One of our Support Analysts will keep
you updated on the progress of your request.
Best Regards,
FATHOM Support Team
TO ADD ADDITIONAL COMMENTS, reply to this email or click the link below:
https://zephyrhillsfl.zendesk.com/hc/requests/223399
............... ...............-1................ ....................................--....................................................--............ ....................................................... ............... ................ ............ ..........
Jacqueline Boges
Jun 29, 5:41 AM MST
full service 3051 moulden hollow dr bp#1 9807-water, sewer, water meter
This email is a service from City of Zephyrhills Support
Jacqueline Boges
From: Nichole Spence(City of Zephyrhills Support)<support@zephyrhillsfl.zendesk.com>
Sent: Saturday, July 14, 2018 11:46 AM
To: Jacqueline Boges
Subject: [FATHOM] Re: 3051 Moulden Hollow dr by#19807
##- Please type your reply above this line -##
Your request (#223399) has been solved. TO REOPEN THIS REQUEST, reply to this email or click the link below:
https://zephyrhilisfl.zendesk.com/hc/requests/223399
.......................................................................................................................................................................................................................................................................................................................................................................................
Nichole Spence (City of Zephyrhills Support )
I- - Jul 14, 8:46 AM MST
Good Morning!
The service order has been created.
Best Regards,
Nichole I FATHOM Support
.......................................................................................................... .................................................................................................................................................................................................................... ......................................
r
Nichole Spence (City of Zephyrhills Support )
Jul 13, 2:26 PM MST
Hello Jacqueline,
Account # 2996709 has been created, service order to follow once mapping has been
completed.
Best Regards,
Nichole I FATHOM Support
........................................................................................................-.... ............................................................................................................................................................................... ............................................................................
' Jacqueline Boges
�- --` Jun 29, 5:41 AM MST
full service 3051 moulden hollow dr by#1 9807-water, sewer, water meter
This email is a service from City of Zephyrhills Support .
1
Lennar Homes-3051 Moulden Hollow Dr-2,376 sq ft
Column ts
SO. FEET PRICE
MAIN OR LIVING: 2,376 $ 112.65
OTHER AREA UNDER ROOF: - $ 88.00
OTHER: - $ -
VALUATION $ 267,656.40
FEE SHEET $ 1,380.00
ADDRESS $ 30.00
DRIVEWAY $ 45.00
BUILDING: $ 1,482.60
ELECTRICAL: $ 310.50
PLUMBING: $ 207.00
MECHANICAL: $ 144.90
SUB-TOTAL $ 2,145.00
TOTAL $ 2,145.00
SEWER: $ 2,090.00
WATER: $ 1,010.00
IRRIGATION: $ -
TOTAL: $ 3,100.00
WATER METER: $ 473.78
IRRIGATION METER
FIRE DEPARTMENT FEES
PLANS TOTAL: n/a
INSPECTION TOTAL:
PERMIT TOTAL
TOTAL: $ -
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
FIRE $ 273.00
5% $ 26.35
TOTAL: $ 553.35
f
SUB-TOTAL $ 6,272.13
PARK IMPACT FEES $ 769.56
SIF'S: $ 7,128.00
100.0% $ 7,128.00
1.0% $ 71.28
TOTAL: $ 7,199.28
T I F'S: $ 3,632.00
99% $ 3,595.68
1% $ 36.32
TOTAL: $ 17,872.97
�I,,LUfiIUH
City of Zephyrhills
BUILDING PLAN REVIEW COMMENTS
Contractor/Homeowner: Le,41",0ZLV--
Date Received:
Site: ^,�3 � ��� Nat)
f
Permit Type:
Approved w/no comments:❑ Approved w/the below comments: Denied w/the below comments: ❑
c� s
This comment sheet shall be kept with the permit and/or plans.
S-a74 f
Kalvin Switzer—Pl s Examiner Date Contractor and/or Homeowner
(Required when comments are present)
24-26-21-0100-00000-0460 1 Pasco County Property Appraiser Page 1 of 1
Data Current as Of: Weekly Archive - Monday, June 11, 2018
Parcel ID 24-26-21-0100-00000-0460 (Card: 001 of 001)
Classification 00 - Vacant Residential
Mailing Address Property Value
LENNAR HOMES LLC Ag Land $0
4600 W CYPRESS ST STE 200 Land $27,540
TAMPA FL 33607-4099 Building $0
Physical Address Extra Features $0
3051 MOULDEN HOLLOW DRIVE
ZEPHYRHILLS, FL 33540
Just Value $27,540
Legal Description (First 4 Lines) Assessed (Non-School Amendment 1) $27,540
HIDDEN RIVER PHASE ONE B
PB 76 PG 077
LOT 46 Taxable Value $27,540
OR 9737 PG 3770
Jurisdiction
City of Zephyrhills
_ Land Detail (Card: 001 of 001)
Line Use De_scri tion'Zonin Units �T ice �—
_ p `g �— Type Price Condition Value
-- 1 j 0100 SFR MPUD 6,000.00 SF -�$4_50— 1.00 $27,000
-- -- - -----� i
2 0100 SFR MPUD 600.00 SF $0.90 i 1.00 j $540
Additional Land InformationFEMA
_
Acres 0.15 ITax Areal 30ZH Code -- Residential Code HDRVLPI
Building Information - Use 00 - Unimproved (Card: 001 of 001)
Unimproved Parcel 00 - Unimproved
_ _ Extra Features (Card: 001 of 001)
Line_ eDescription_____Year Units _ . jValuei
No Extra Features
Sales History - See All 6 sales
Previous Owner: DUNE FL LAND I SUB LLC
Month/Year Book/Page Type OD Code Condition Amount
06/2018 _ 9737 / 3770 - Warranty Deed � 05 -- _ Vacant j Multi-Parcel Sale
— 09/2011_ j 8606 / 3376 _Warranty Deed—� 05 Vacant Multi-Parcel Sale
06/2010 T 8360 / 1872 Certificate of Title j 12 Vacant j $0
http://search.pascopa.com/parcel.aspx?parcel=2126240100000000460 6/15/2018
DASD® COUNTY, FLORIDA
Permit No. qteo
Date Permitted
Bu ilder Name/Owner Name 4vtt Control#
County Parcel No.
Address/Location 366[ No�dd)! lloO
Classification/Type of Use 'Sllrde "1'6�
U
TRANSPORTATION IMPACT FEE . Rate: Sq.FtUnit:
Exempt nYei [] No How Determined
Impact Fee Amount $.3j 3 Zone No. TAZ:
SCHOOL IMPACT FEE
Account (056) Single-Family Detached House Amount $ 3 t I I 7—f 3
(057) Mobile Home
(058) Other Residential
23) Collection Fee
Exempt �Yes R No How Determined
PARKS AND RECREATION FEE
Land Account Land Credit Land Total
Recreation Account Recreation Credit Recreation Total
Zone TOTAL AMOUNT $ 76
Exempt F]Yes n No How Determined
LIBRARY FEE
Land Account Land Credit Land Total
Facility Account Facility Credit Facility Total
Exempt R Yes F] No How Determined Total Amount
RESOURCE FEE ERU
TOTAL AMOUNT
A
Prepared By Checked By
V U
NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION
PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE
BEEN PAID AND
RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE.OF PASCO COUNTY
Acknowledgement below does not Imply acceptance of concurrence,but simply receipt of-a copy of this form,placing
the building permit owner,on notice of this assessment and the conditions of payment for same.
DATE RECEIVED BY
RECEIPT NO. DATE BY
Lennar Homes-3051 Moulden Hollow Dr-2,376 sq ft
o umn Its
SO. FEET PRICE
MAIN OR LIVING: 2,376 $ 112.65
OTHER AREA UNDER ROOF: - $ 88.00
OTHER: $ -
VALUATION $ 267,656.40
FEE SHEET $ 1,380.00
ADDRESS $ 40.00
DRIVEWAY $ 40.00
BUILDING: $ 1,487.60
ELECTRICAL: $ 310.50
PLUMBING: $ 207.00
MECHANICAL: $ 144.90
SUB-TOTAL $ 2,150.00
TOTAL $ 2,150.00
SEWER: $ 2,090.00 n/a
WATER: $ 1,010.00 n/a
IRRIGATION: $ -
TOTAL: $ 3,100.00
WATER METER:1 $ 473.78 n/a
IRRIGATION METER $ -
FIRE DEPARTMENT FEES
PLANS TOTAL: n/a
INSPECTION TOTAL:
PERMIT TOTAL
TOTAL: $ -
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
FIRE $ 273.00
5% $ 26.35
TOTAL: $ 553.35
SUB-TOTAL $ 6,277M
PARK IMPACT FEES $ 769.56
SIF'S: $ 7,128.00
100.0% $ 7,128.00
1.0% $ 71.28
TOTAL: $ 7,199.28
T I F'S: $ 3,632.00
99% $ 3,595.68
1% $ 36.32
TOTAL: $ 17,877.97
Single Family Dwelling
Pla n Review.. omments
1; F.F-E.shall-'be a;zninimuri�:of 8" above.the road elevation and an engineered.site plan.
.
2. Lots shall be'graded.to.corriply withR401.3 .of the F.B:C:
3. Compaction:test required.if 24" or more of fill dirt is brouglit in at any one place:
4: :Tie in surveyrequired before pouring concrete.
5. Driveways:require a R:(O:W. use permit:: All 4:sides of driveway.thru the sidewalk shall have
expans,ion material..
6- All,setbacks.shall be met.::
-7.. All.property:markers shall be,uncovered and iizarked.at time of first:inspection:
.8. :All A.D.A:requirements shall be met. .
9. No:electric-'plumbing,.mechanical,,or framing shall be covered without an inspection.and
approval first,
10. All Garages shall comply:with section R302;6,of the F.B.C.-(Fire S.eparation)..
11._Appliances shall not=be installed in.a location where subject to,mechanical'damdae unless
protected byapproved barriers: M303.4 of the F.B:C
12. Water heaters shall_comply with section:P607.3 of the F.B.C:
13. Foundation'supports for A/C.units shall be raised at least 3" above finished-grade,. M1308.1
14. Return air in altbedrooms,F.B.C. M1620:4
15. Smoke detectors are.to be:installed:in accordan.ce.with:R31'3:1 of the:F.B.C.
16:.All glazing requirements are.to be in accordance with R308.4_of the.F.B:C. .
17. A11 means,of egress are to:be in accordance with R3 It of the F&C.. ::
18. "Green gypsum board"shall not be used as-a backer,in showers or tubs. R702:4>2:F.B.C;
. .
19. Combination-type AFCI breakers.are,mouired at all locations requiring an AFCI.type breaker:
- 20: Carbon monoxide aiarins will be required in riew:c' structionthat uses fossil-burning heating
or appliances or an attached garage: They shall be.installed'ini accordancewith,the F.B.C.
21. All plumbing,mechanical,:and.electrieal shall:be separate from unit.to unit: This includes all
underground plunribiiig acid electric: -
22. All 2011:N:E:C: Codes.will be-enforced:
23. Tamper=Resistant Receptacles in accordance wvith 40.6.11 of the 2011 ME:C
24:.Iri accgrdance_ivith the Land Development:Code' lots.shall be sadded'before final at least-10
feet::around the structure.
ZS R copy ofthe enemy eacZs shall be with pertnit-t t all dines
26. Copy of r1nal insulation report shall be.provided with.peMiit_beforel"ha
F.F:E.-Finished Floor Elevation
F.B:C- Florida Building Code 6t'Edition
R:O.W-Right:of Way ,
A.D.A.-Americans with Disabilities Act : N.E.C.-National Electric Code (2011).
2
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: 1941BI sf ADS Carrier Builder Name: Lennar Homes
Street: 3051 Moulden Hollow Drive Permit Office: City of Zephyrhffls
City,State,Zip: FL, Permit Number: t-?150-7
Owner., Lennar Homes Jurisdiction: 611600
Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2
1. New construction or existing New(From Plans) 9. Wall Types(1961.3 sqft.) Insulation I' Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1454.60 ft2
b.Frame-Wood,Adjacent R=1 1.0 506.78 ft2
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 4 d.N/A R= ft2
10.Ceiling Types (1936.0 sqft.) Insulation Area
5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1936.00 ft2
6. Conditioned floor area above grade(ft2) 1936 b.N/A R= W
Conditioned floor area below grade(ft2) 0 c.N/A R= ft2
11.Ducts R ft2
7. Windows(157.3 scift.) Description Area a.Sup:Attic,Ret:family rm,AH:laundry rm 6 387.2
a. U-Factor: Dbl,U=0.54 101.00 ft2
SHGC; SHGC=0.31
b. U-Factor Dbl,U=0.56 33.33 ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.32 a.Central Unit 34.8 SEER:15.00
c. U-Factor. Dbl,U=0.56 23.00 ft2
SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a.Electric Heat Pump 34.6 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 1.212 ft.
Area Weighted Average SHGC: 0.308 14.Hot water systems
8. Floor Types (1936.0 sqft.) Insulation Area a.Electric Cap:40 gallons
a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ft2 b. Conservation features EF:0.950
b.N/A R= ft2 None
c.N/A R= ft2 15.Credits Pstat
Glass/Floor Area: 0.081 Total Proposed Modified Loads: 62.46 PASS
Total Baseline Loads: 62.81
I hereby certify that the plans and specifications covered by Review of the plans and
this calculation are in compliance with the Florida Energy specifications covered by this
Code calculation indicates compliance
with the Florida Energy Code.
PREPARED BY: Da Ile OiCh Before construction is completed
DATE: this building will be inspected for
compliance with Section 553.908
I hereby certify that this building,as designed,is in compliance Florida Statutes,
with the Florida Energy Code.
OWNER/AGENT:. MAY 0 3 2018 BUILDING OFFICIAL:
DATE: - DATE:
- Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 6.50 ACH50(R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSIIRESNETIICC 380,is not greater than 0.030 Qn for whole house.
5/1/2018 12:22 PM EnergyGauge@ USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 6
s
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: 1941 B1 sf ADS Carrier Builder Name: Lennar Homes
Street: 3051 Moulden Hollow Drive Permit office: City of Zephyrhills
City,State,Zip: FL, Permit Number:
Owner. Lennar Homes Jurisdiction:' 611600
Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(1961.3 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1454.60 ftz
b.Frame-Wood,Adjacent R=11.0 506.78 ftz
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 4 d•N/A R= ftz
5. Is this a worst case? Yes 10.Ceiling Types (1936.0 sqft.) Insulation Area
a.Under Attic(Vented) R=30.0 1936.00 ftz
6. Conditioned floor area above grade(ftz) 1936 b.N/A R= ftz
Conditioned floor area below grade(ftz) 0 c.N/A R= ftz
11.Ducts R ftz
7. Windows(157.3 sqft.) Description Area a.Sup:Attic,Ret:family rm,AH:laundry rm 6 387.2
a. U-Factor: Dbl,U=0.54 101.00 ftz
SHGC: SHGC=0.31
b. U-Factor: Dbl,U=0.56 33.33 ftz 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.32 a.Central Unit 34.8 SEER:15.00
c. U-Factor: Dbl,U=0.56 23.00 ftz
SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ftz a.Electric Heat Pump 34.6 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 1.212 ft.
Area Weighted Average SHGC: 0.308 14.Hot water systems
8. Floor Types (1936.0 sqft.) Insulation Area a.Electric Cap:40 gallons
a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ftz b. Conservation features EF:0.950
b.N/A R= ftz None,
c.N/A R= ftz 15.Credits Pstat
Glass/Floor Area: 0.081 !1
Total Proposed Modified Loads: 62.46 PASS
SS
Total Baseline Loads: 62.81
I hereby certify that the plans and specifications covered by Review of the plans and ' ks `
this calculation are in compliance with the Florida Energy specifications covered by this Off^ r
Code. calculation indicates compliance
with the Florida Energy Code. F.- jnri ��%% •=�'=.�'.;•�,�=0
PREPARED BY: Dave AulichBefore construction is completed
DATE: this building will be inspected for I' F 7
compliance with Section 553.908
herebycertify that this building,as designed, is in compliance Florida Statutes. Ks
fY 9� 9 � P
with the Florida Energy Code. OZj`y
OWNER/AGENT: MAY O 3 2018 BUILDING OF ICIAI
DATE: DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires'an
envelope leakage test report with envelope leakage no greater than 6.50 ACH50(R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house.
5/1/2018 12:22 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Pagel of 6
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: 1941 B1 sf ADS Carrier Builder Name: Lennar Homes
Street: 3051 Moulden Hollow Drive Permit office: City of Zephyrhills
City,State,Zip: FL, Permit Number:
Owner. ' Lennar Homes Jurisdiction: 611600
Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(1961.3 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1454.60 ft2
b.Frame-Wood,Adjacent R=11.0 506.78 ft2
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 4 d.N/A R= ft2
5. Is this a worst case? Yes 10.Ceiling Types (1936.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1936.00 ft2
6. Conditioned floor area above grade(ft2) 1936 b.N/A R= ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ft2
11.Ducts R ft2
7. Windows(157.3 sqft.) Description Area a.Sup:Attic,Ret:family rm,AH:laundry rm 6 387.2
a. U-Factor: Dbl,U=0.54 101.00 ft2
SHGC: SHGC=0.31
b. U-Factor: Dbl,U=0.56 33.33 ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.32 a.Central Unit 34.8 SEER:15.00
c. U-Factor: Dbl,U=0.56 23.00 ft2
SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a.Electric Heat Pump 34.6 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 1.212 ft.
Area Weighted Average SHGC: 0.308 14.Hot water systems
8. Floor Types (1936.0 sqft.) Insulation Area a.Electric Cap:40 gallons
EF:0.950
a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ft2 b. Conservation features
b.N/A R= ft2 None
c.N/A R= ft2 15.Credits Pstat
Glass/Floor Area: 0.081 Total Proposed Modified Loads: 62.46 PASS
Total Baseline Loads: 62.81
I hereby certify that the plans and specifications covered by Review of the plans and ;p .tk1E-STD
this calculation are in compliance with the Florida Energy specifications covered by this
Code. calculation indicates compliance
with the Florida Energy Code.
PREPARED BY: Dave Aupich, ' Before construction is completed
DATE: this building will be inspected for ,1 - -
compliance with Section 553.908 ,
hereby certify that this building,as designed, is in compliance Florida Statutes. ;
with the Florida Energy Code. �''OD
OWNER/AGENT: YMAY O 3 2018 BUILDING OFFICIAl
DATE: 4,Z DATE: -
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 6.50 ACH50(R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.030 Qn for whole house.
5/1/2018 12:22 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 6
FORM R405-2017
PROJECT
Title: 1941 B1 sf ADS Carrier Bedrooms: 4 Address Type: Street Address
Building Type: User Conditioned Area: 1936 Lot#
Owner Name: Lennar Homes Total Stories: 1 Block/Subdivision:
#of Units: 1 Worst Case: Yes PlatBook:
Builder Name: Lennar Homes Rotate Angle: 45 Street:
Permit Office: Cross Ventilation: No County: Pasco
Jurisdiction: Whole House Fan: No City,State,Zip:
Family Type: Single-family FL,
New/Existing: New(From Plans)
Comment: FBC 2017
CLIMATE
Design Temp Int Design Temp Heating Design Daily Temp
Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,Tampa FL_TAMPA_INTERNATI 39 91 70 75 645.5 54 Medium
BLOCKS
Number Name Area Volume
1 Entire House 1936 16360.3
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
1 master 210 1680 No 2 1 1 Yes Yes Yes
2 family rm 341 3171.3 No 0 1 Yes Yes Yes
3 cafe 161 1288 No 0 1 Yes Yes Yes
4 kit 182 1692.6 Yes 0 1 Yes Yes Yes
5 bdrm2 147 1176 No 1 1 1 Yes Yes Yes
6 bdrm3 149 1192 No 1 1 1 Yes Yes Yes
7 bath2 61 488 No 0 1 Yes Yes Yes
8 bdrm4 149 1192 No 1 1 1 Yes Yes Yes
9 o wic 104 832 No 0 1 Yes Yes Yes
10 privy 24 192 No 0 1 Yes Yes Yes
11 o bath 117 936 No 0 1 Yes Yes Yes
12 laundry rm 100 800 No 0 1 Yes Yes Yes
13 foyer 148 1376.4 No 0 1 Yes Yes Yes
14 hall 43 344 No 0 1 Yes Yes Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio master 29.5 ft 0 212.3 ft2 -_ 0 0 1
2 Slab-On-Grade Edge Insulatio family rm 14.5 ft 0 340.8 ft2 0 - 0 1
3Slab-On-Grade Edge Insulatio cafe 25.5 ft 0 161 ft2 0 0 1
4 Slab-On-Grade Edge Insulatio kit 13.5 ft 0 182.3 ft2 N 1 0 0
5/1/2018 12:22 PM EnergyGaugeO USA-FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 6
f
FORM R405-2017
FLOORS
# Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet
5 Slab-On-Grade Edge Insulatio bdrm2 10.5 ft 0 146.8 ft2 ___ 0 0 1
6 Slab-On-Grade Edge Insulatio bdrm3 13.5 ft 0 148.5 ft2 _ 0 0 1
7 Slab-On-Grade Edge Insulatio bath2 5.5 ft 0 60.5 ft2 __ 1 0 0
8 Slab-On-Grade Edge Insulatio bdrm4 35.5 ft 0 148.5 ft2 0 0 1
9 Slab-On-Grade Edge Insulatio o wic 21 ft 0 104 ft2 ___ 0 0 1
10SIab-On-Grade Edge Insulatio privy 1 ft 0 24 ft2 __ 1 0 0
11SIab-On-Grade Edge Insulatio o bath 10.5 ft 0 117.3 ft2 1 0 0
12SIab-On-Grade Edge Insulatio laundry rm 9 ft 0 100 ft2 1 0 0
13SIab-On-Grade Edge Insulatio foyer 22.5 ft 0 147.5 ft2 __ 1 0 0
14SIab-On-Grade Edge Insulatio hall 2 ft 0 42.5 ft2 ___ 0 0 1
ROOF
Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
1 Hip Composition shingles 2097 ft2 0 ft2 Medium 0.85 No 0.9 No 0 22.6
ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Vented 300 1936 ft2 N N
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Vented) master 30 Blown 210 ft2 0.1 Wood
2 Under Attic(Vented) family rm 30 Blown 341 ft2 0.1 Wood
3 Under Attic(Vented) cafe 30 Blown 161 ft2 0.1 Wood
4 Under Attic(Vented)' kit 30 Blown 182 ft2 0.1 Wood
5 Under Attic(Vented) bdrm2 30 Blown 147 ft2 0.1 Wood
6 Under Attic(Vented) bdrm3 30 Blown 149 ft2 0.1 Wood
7 Under Attic(Vented) bath2 30 Blown 61 ft2 0.1 Wood
8 Under Attic(Vented) bdrm4 30 Blown 149 ft2 0.1 Wood
9 Under Attic(Vented) o wic 30 Blown 104 ft2 0.1 Wood
10 Under Attic(Vented) privy 30 Blown 24 ft2 0.1 Wood
11 Under Attic(Vented) o bath 30 Blown 117 ft2 0.1 Wood
12 Under Attic(Vented) laundry rm 30 Blown 100 ft2 0.1 Wood
13 Under Attic(Vented) foyer 30 Blown 148 ft2 0.1 Wood
14 Under Attic(Vented) hall 30 Blown 43 ft2 0.1 Wood
5/1/2018 12:22 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 6
FORM R405-2017
WALLS
Adjacent Space Cavity Width Height Sheathing Framing Solar Below
1 S=>SW Exterior Concrete Block-Int Insul master 4.1 12 6 8 0 100.0 ft2 0 0 0.6 0
2 W=>NW Exterior Concrete Block-Int Insul master 4.1 17 . 0 8 0 136.0 ft2 0 0 0.6 0
3 S=>SW Exterior Concrete Block-Int Insul family rm 4.1 14 6 9 4 135.3 ft2 0 0 0.6 0
4 E=>SE Exterior Concrete Block-Int Insul cafe 4.1 12 0 8 0 96.0 ft2 0 0 0.6 0
5 S=>SW Exterior Concrete Block-Int Insul cafe 4.1 13 6 8 0 108.0 ft2 0 0 0.6 0
6 E=>SE Exterior Concrete Block-Int Insul kit 4.1 13 6 9 4 126.0 ft2 0 0 0.6 0
7 E=>SE Exterior Concrete Block-Int Insul bdrm2 4.1 10 6 8 0 94.0 ft2 0 0 0.6 0
8 E=>SE Exterior Concrete Block-Int Insul bdrm3 4.1 13 6 8 0 108.0 ft2 0 0 0.6 0
9 E=>SE Exterior Concrete Block-Int Insul bath2 4.1 5 6 8 0 44.0 ft2 0 0 0.6 0
10 N=>NE Exterior Concrete Block-Int Insul bdrm4 4.1 13 6 8 0 108.0 ft2 0 0 0.6 0
11 E=>SE Exterior Concrete Block-Int Insul bdrm4 4.1 11 0 8 0 88.0 ft2 0 0 0.6 0
12 W=>NW Exterior Concrete Block-Int Insul bdrm4 4.1 11 0 8 0 88.0 ft2 0 0 0.6 0
13 N=>NE Garage Frame-Wood o wic 11 28 4 8 0 226.7 ft2 0 0.25 0.01 0
14 W=>NW Exterior Concrete Block-Int Insul o wic 4.1 8 0 8 0 64.0 ft2 0 0 0.6 0
15 W=>NW Exterior Concrete Block-Int Insul o bath 4.1 10 6 8 0 84.0 ft2 0 0 0.6 0
16 N=>NE Garage Frame-Wood laundry rm 11 17 5 8 0 139.3 ft2 0 0.25 0.01 0
17 N=>NE Exterior Concrete Block-Int Insul foyer 4.1 5 0 9 4 46.7 ft2 0 0 0.6 0
18 W=>NW Garage Frame-Wood foyer 11 15 1 9 4 140.8 ft2 0 0.25 0.01 0
19 W=>NW Exterior Concrete Block-Int Insul foyer 4.1 2 5 9 4 22.6 ft2 0 0 0.6 0
20 W=>NW Exterior Concrete Block-Int Insul hall 4.1 2 0 8 0 16.0 ft2 0 0 0.6 0
DOORS
# Ornt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 N=>NE Wood laundry rm None .4 2 8 6 8 17.8 ft2
2 N=>NE Insulated foyer None .2 3 6 8 20 ft2
WINDOWS
Orientation shown is the entered orientation =>)changed to Worst Case.
Wall Overhang
v # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening
1 S=>SW 1 Metal Low-E Double Yes 0.54 0.31 N 23.0 ft2 1 ft 0 in 0 ft 10 in None None
2 S=>SW 3 Metal Low-E Double Yes 0.54 0.31 N 46.0 ft2 1 ft 0 in 0 ft 10 in None None
3 S=>SW 5 Metal Low-E Double Yes 0.56 0.32 N 33.3 ft2 2 ft 0 in 0 ft 4 in None None
4 E=>SE 7 Metal Low-E Double Yes 0.54 0.31 N 16.0 ft2 1 ft 0 in 0 ft 10 in None None
5 E=>SE 8 Metal Low-E Double Yes 0.54 0.31 N 16.0 ft2 1 ft 0 in 0 ft 10 in None None `
6 N=>NE 10 Metal Low-E Double Yes 0.56 0.28 N 23.0 ft2 1 ft 0 in 0 ft 10 in None None
5/1/2018 12:22 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 6
r
FORM R405-2017
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 416ft2 416ft2 43.7ft 8ft 1
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000349 1772.4 97.3 182.99 .2618 6.5
HEATING SYSTEM
# System Type Subtype Efficiency Capacity Block Ducts
1 Electric Heat Pump/ Split HSPF:8.5 34.6 kBtu/hr 1 sys#1
COOLING SYSTEM
# System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts
1 Central Unit/ Split SEER:15 34.8 kBtu/hr 1044 cfm 0.85 1 sys#1
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.95 40 gal 70 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cert # Company Name System Model# Collector Model# Area Volume FEF
None None ft2
DUCTS
/ —Supply— —Return— Air CFM 25 CFM25 HVAC#
V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 387.2 ft family rm 96.8 ft2 Proposed Qn laundry rm —cfm 58.1 cfm 0.03 0.50 1 1
5/1/2018 12:22 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 6
FORM R405-2017
TEMPERATURES
Programable Thermostat:Y Ceiling Fans:
Coolin H Jan Feb Mar A r Ma X Jun ri Jul rj Au ri
Se Oct Nov Dec
Heating JanFeb ki
Mar _ ArMay Jun Jul Au Sep E Oct Nov HDec
Ventin Jan Feb Mar [x Apr [ May Jun Jul Aug Se [X Oct H
Nov Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
5/1/2018 12:22 PM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 6 of 6
FORM R405-2017
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the EnergyPerformance Index, the more efficient the home.
„ FL,
1. New construction or existing New(From Plans) 9. Wall Types Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1454.60 ft2'
b.Frame-Wood,Adjacent R=11.0 506.78 ft
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 4 d.N/A R= ft2
10.Ceiling Types Insulation Area
5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1936.00 ft2
6. Conditioned floor area(ft2) 1936 b.N/A R= ft2
7. Windows- Description Area c.N/A R= ft2
2
a. U-Factor: Dbl,U=0.54 101.00 ft2 11.Ducts R ft
a.Sup:Attic,Ret:family rm,AH:laundry rm 6 387.2
SHGC: SHGC=0.31
b. U-Factor: Dbl,U=0.56 33.33 ft2
SHGC: SHGC=0.32 12.Cooling systems kBtu/hr Efficiency
c. U-Factor: Dbl,U=0.56 23.00 ft2 a.Central Unit 34.8 SEER:15.00
SHGC: SHGC=0.28
d. U-Factor. N/A ft2 13.Heating systems kBtu/hr Efficiency
SHGC: a.Electric Heat Pump 34.6 HSPF:8.50
Area Weighted Average Overhang Depth: 1.212 ft.
Area Weighted Average SHGC: 0.308
8. Floor Types Insulation Area 14.Hot water systems
a.Electric Cap:40 gallons
a.Slab-On-Grade Edge Insulation R=0.0 1936.00 ft2 EF:0.95
b.N/A R= ft2
c.N/A R= ft2 b. Conservation features
None
15.Credits Pstat
certify that this home has complied with the Florida Energy Efficiency Code for Building ;� SpA..
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
V .
Builder Signature: Date: 05/01/1831
Address of New Home: 3051 M lden Hollow Drive City/FL Zip: Zephyrhills,FL 33540 GOD �5 .
*Note This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at
techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of
certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building
Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
5/1/2018 12:24 PM EnergyGauge®USA-FlaRes2017 -Section R405.4.1 Compliant Software Page 1 of 1
Buildin Anal SIS Job: 1941B1 sf ADS Carrier
g Y Date: 5/1/2018
Entire House By: Dave
Bayonet Plumbing Heating and Air
Project Information
For: Lennar Homes
Design Conditions
Location: Indoor: Heating Cooling
Tampa International AP, FL, US Indoor temperature(°F) 70 75
Elevation: 10 ft Design TD ff) 39 16
Latitude: 28°N Relative humidity (%) 50 50
Outdoor: Heating Cooling Moisture difference(gr/lb) 34.7 54.7
Dry bulb(°F) 31 91 Infiltration:
Daily range(°F) - 14 ( L ) Method Simplified
Wet bulb ff) - 77 Construction quality Semi-tight
Wind speed (mph) 15.0 7.5 Fireplaces 0
MEN M,
Component Btuh/ftz Btuh % of load
Walls 5.6 7036 25.5 Uas
Glazing 30.2 4709 17.0 wa10ther
Doors 23.5 466 1.7 nfiltration
Ceilings 1.3 = 2429 8.8
Floors 3.5 6726 24.3
Infiltration 2.1 3056 11.1
6 Ducts 3221 11.7
Piping 0 0 Glazing Floors
Humidification 0 0
,.Ventilation 0 0Ceilings
Adjustments 0
Total 27641 100.0
Component Btuh/ftz Btuh % of load
Walls 2.8 3500 13A walls
Glazing 56.7 8852 33.2 Internal Gains
Doors 18.4 365 1.4
Ceilings 1.7 3358 12.6
Floors 0 0 0
Infiltration 0.5 684 2.6
Ducts 3628 13.6
Ventilation 0 0 Glazing Ducts
Internal gains 6240 23.4
Blower 0 0 Infiltration
Adjustments 0
Total 1 1 26627 100.0 Other Ceilings
Latent Cooling Load= 3680 Btuh
Overall U-value= 0.103 Btuh/ftz-°F
.Data entries checked.
=ightsc ft- 2018-May-01 12:35:12
^�^ w^- Right-SuRe®Universal2018 18.0.16 RSU05714 Page 1
..equipment\1941 sf ADS template 3ton Camer.rup Cale=MJ8 Front Door faces:NE
Project Summary Job: 1941B1 sf ADS Carrier
ry Date: 5/1/2018
Entire House By: Dave
Bayonet Plumbing Heating and Air
PMect Information
For: Lennar Homes
Notes: FBC 2017
Design Information
Weather: Tampa International AP, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 31 OF Outside db 91 OF
Inside db 70 OF Inside db 75 OF
Design TD 39 OF Design TD 16 OF
Daily range L
Relative humidity 50 %
Moisture difference 55 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 24421 Btuh Structure 22999 Btuh
Ducts 3221 Btuh Ducts 3628 Btuh
Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh
(none) (none)
Humidification 0 Btuh Blower 0 Btuh
Piping 0 Btuh
Equipment load 27641 Btuh Use manufacturer's data y
Rate/swing multiplier 1.00
Infiltration Equipment sensible load 26627 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Semi-tight
Fireplaces 0 Structure 3019 Btuh
Ducts 660 Btuh
Central vent (0 cfm) 0 Btuh
Heating Cooling (none)
Area(ft') 1936 1936 Equipment latent load 3680 Btuh
Volume(ft') 16360 16360
Air changes/hour 0.26 0.14 Equipment Total Load (Sen+Lat) 30307 Btuh
Equiv.AVF (cfm) 71 38 Req. total capacity at 0.85 SHR 2.6 ton
Heating Equipment Summary Cooling Equipment Summary
Make Carrier Make Carrier
Trade Trade
Model 25HBC536AO0300 Cond 25HBC536AO0300
AHRI ref 9155179 Coil FX4DNF037L
AHRI ref 9155179
Efficiency 8.5 HSPF Efficiency 12.0 EER, 15 SEER
Heating input Sensible cooling 29580 Btuh
Heating output 34600 Btuh @ 47'F Latent cooling 5220 Btuh
Temperature rise 26 OF Total cooling 34800 Btuh
Actual air flow 1200 cfm Actual air flow 1200 cfm
Air flow factor 0.043 cfm/Btuh Air flow factor 0.045 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.88
Capacity balance point=26 OF
Backup: n/a n/a
Input= 0 kW, Output= 0 Btuh, 100 AFUE
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
-Fk- wrightsoft- 2018-May-01 12:35:12
^�^•� ••^- .......... Right-Suite®Universal 2018 18.0.16 RSU05714 Pagel
..equipment\1941 sf ADS template 3ton Carrier.rup Calc=MJ8 Front Door faces:NE
Manual S Compliance Report Job: 1941B1 sf ADS Carrier
Date: 5/1/2018
Entire House By: Dave
Bayonet Plumbing Heating and Air
Project Information
For: Lennar Homes
Cooling Equipment
Design Conditions
Outdoor design DB: 91.3°F Sensible gain: 26627 Btuh Entering coil DB: 75.6°F
Outdoor design WB: 77.3°F Latent gain: 3680 Btuh Entering coil WB: 62.8°F
Indoor design DB: 75.0°F Total gain: 30307 Btuh
Indoor RH: 50% Estimated airflow: 1200 cfm
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: Split ASHP
Manufacturer: Carrier Model: 25HBC536A00300+FX4DNF037L
Actual airflow: 1200 cfm
Sensible capacity: 29580 Btuh 111% of load
Latent capacity: 5220 Btuh 142% of load
Total capacity: 34800 Btuh 115% of load SHR: 85%
Heating Equipment
Design Conditions
Outdoor design DB: 30.8°F Heat loss: 27641 Btuh Entering coil DB: 69.7°F
Indoor design DB: 70.0°F
,
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: Split ASHP
Manufacturer: Carrier Model: 25HBC536A00300+FX4DNF037L
Actual airflow: 1200 cfm
Output capacity: 26331 Btuh 95% of load Capacity balance: 26 OF
Supplemental heat required: 1310 Btuh Economic balance: -99 OF
Backup equipment type: Elec strip
Manufacturer: n/a Model: n/a+n/a
Actual airflow: 1200 cfm
Output capacity: 0 kW 0% of load Temp. rise: 0 OF
Meets all requirements of ACCA Manual S.
Wrlghtsoft, 2018-May-0112:35:12
Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1
�iCk ...equipment\1941 sf ADS template 3ton Carrierrup Cale=MJ8 Front Door faces:NE
2018104316
Rept-1967343 Rec: 10-00
DS: 0.00 IT: 0.00
06/20/2018 K. A. , Dpty Clerk_
PAULA S.O'NEIL,Ph.D.PnSCO CLERK t COMPTROLLD
06/20/ 197418 02:25 1 f I
OR BK20 ' Pr, 01205
Permit No. Parcel ID No 24-26-21-0100-00000-0460
NOTICE OF COMMENCEMENT
state of Florida County of Pasco
THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 713,Florida Statutes,
the following information is provided in this Notice of Commencement:
1. Description of Property: Legal HIDDEN RIVER PHASE ONE B PB 76 PG 77 LOT 46
Street Address: -3051 .Moulden Hollow Drive Zephryhills FL 33541
2. General Description of Improvement Single Family Residence J Pool J Screen Enclosure I Fence
3. Owner Information: Lennar Homes, LLC.
Name
4600 W Cypress St,Ste 200 Tampa FL. 33607
Address city State
Interest in Property:
Name of Fee Simple Titleholder: N/A
(If other than owner)
Address City State
4. Contractor: Lennar Homes, LLC
Name
4600 W Cypress St,Ste 200 Tampa FL,33607
Address city State
Contractor's Telephone No.: 813.574,5700
5. Surety: N/A
Name
Address city State
Amount of Bond: $ Telephone No.:
6. Lender: N/A
Name
Address city State
Lender's Telephone No.:
7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by
Section 713.13(1)(a)(7),Florida Statutes:
Lennar Homes. LLC
Name
4600 W Cypress St, Ste 200 Tampa FL,33607
Address ' city State
Telephone Number of Designated Person: _81 3.574.5700
8. In addition to himself,the owner designates N/A Of
to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statutes.
Telephone Number of Person or Entity Designated by Owner:
9. Expiration date of Notice of.Commencement is one year from the date of recording unless a different date Is specified:
WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT
ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE
RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OFCOMMENCEMENT.
STATE OF FLORIDA
COUNTY.OF PINELLAS
Signature of Owner or Owner's Authorized Officer/Director/Partner/Manager
Vice President
Signatory's Title/Office
The foregoing instrument was.acknowledged before me this-10—day of March by
Steve Robert Smith as Vice President
(type of auPoowl-g—,officer, stee,attorney in fact)for
Lennar Homes-, LLC (na e,of party on6half of whoweKstrument was executed).
Personally Known A OR Produced Identification 0 Notary SI na e
Type of Identification Produced Name(Prink
_EUsgTGf9ira�n'--
Verification pursuant to Section 92.525,Florida Statutes. Under penalties of perjury,I declare that I have read the foregoing and that the facts stated in
it are true to the best of my knowledge and belief.
Signature of Natural Person Signing Above
41111rel Juno 8.9020.
wpdata/bcs/br-s form! ftillonrOmpkiri 11-purana"a-m7clil
��Mnnirnunm ■r —-- ---- —a;�.'—"`.-"_._.""'- i i ua ni IIIIIIMVA.I�YMI
� � ■� IrMrf ` ! � M�RIIIIM -� OII�AI�I
�' .. +.• +fir `R 1
FFEL
A 771,
A
! FF1.
w 1', � D
w °
ram
76,
1FF ELtr
A , la
A � .� '� N
�.. � NPV
7. .�
LA I
PIK
74
Af
73
cp
taw: ':o-� t$ .." y..•'�,«,S � ..•'" � ��■ x it .
OW
PH
lAu
't•`' {gat r,,..t�' «+�' «"r• f ► _
72.71144
fR •tRi • r a
A .-0 rF� ?1
FFEL
C7@a .may .' fFOL
Fn
� .. .r' .,' _+ _ .9a ..ir � � w • w• �■ a Yr e
sPpi awl' . ��,j�'�•' !t i1 i i i •d
FF
• + • a . e�� 47 � ��•t �• • i i i i i i •i
do
ow
�-:_� a:3;• 1 �'t t� � 4VV � r✓s '
Ff EL
1.55
1-10
,N^:.J�, •`' :';i': 1:4jt .�L fir*'' .+ .',, , '.t''y �� �L4 FF
,ry .', ,i• ',� fir,, y'''! . «+' 3
71
..�".;"�•.: •+SVI.''� t . '�� ..«'� y*,. � `• yam,..•^"` r,.+-
�4�• '�. 3�' �•�
PLOT PLAN SKETCH ONLY NOT A BOUNDARY SURVEY SEC. 24 TWP. 26 S, RNG. 21 E.
LOT 46 BEARING BASIS:
HIDDEN RIVER PHASE ONE B NORTH BOUNDARY OF SUBJECT PLAT BEING S 89°40'43" E
PASCO COUNTY, FLORIDA. THIS SURVEY IS SUBJECT TO ANY FACTS THAT
MAY BE DISCLOSED BY A FULL AND ACCURATE
ON LOT AREA CALCULATIONS TITLE SEARCH. ALSO SUBJECT TO SETBACKS,
LOT = 6600_00 gQ, Fr,
EASEMENTS AND RESTRICTIONS OF RECORD.
LIVING AREA = 1_566---SQ. FT, o UNDERGROUND FOOTER, STEM WALL, AND
ENTRY = 40 ---SQ. FT, 7
GARAGE = 407 SQ. FT, UNDERGROUND UTILITIES ARE NOT LOCATED OR
COVERED LANAI =_NLSO. FT. II SHOWN.
PATIO = 23 SQ. FT. DO NOT SCALE THIS PRINT. DIMENSIONS AND
POOL AREA =_NZSQ. FT.
Gj NOTES TAKE PREFERENCE.
CONC. DRIVE = 475 `SQ, Fr, �
A/C & CONC PAD = 9-__SQ. Fr. DESCRIPTION NOT CONTAINING PLAT BOOK AND
PRIVATE SIDEWALK =_29 ____SQ. Fr, PAGE INDICATES THAT PLAT IS IN
IMPERVIOUS =_36 __% PRELIMINARY STAGE AND IS SUBJECT TO
2539 ___gQ, FT, CHANGE AND/OR REVISION.
SOD =_4061___SQ. Fr,
OFF LOT AREA CALCULATIONS CERTAIN DATA SHOWN HEREON BASED ON
RIGHT OF WAY = 720.00 SQ. Fr, ENGINEERING PLANS PROVIDED BY CLIENT.
DRIVE APRON = 144 _SQ. Fr, STRUCTURE TIES SHOWN HEREON DENOTES
PUBLIC SIDEWALK 240 SQ, Fr,SOD 336___.SQ. Fr. MEASUREMENT FROM FORM BOARDS/FOUNDATION
=_
TO PROPERTY LINE.
TOTALS
AREA =_73 * = 10' DRAINAGE/UTILITY EASEMENT
20_00 SQ. Fr.
DRIVEWAY = 619 ---SQ. FT. PRM(P)
SIDEWALK = 269 _SQ. Fr.
SOD =_4397__SQ. Fr,
PRELIMINARY DRAWING:
THIS PLAN IS FOR PERMITTING PURPOSES �o °
ONLY, NOT FOR CONSTRUCTION. VERIFY
ALL DIMENSIONS BEFORE ANY CONSTRUCTION. O
LEGEND:
f-�= PROPOSED DRAINAGE FLOW
(00.00) = PROPOSED GRADE
E-00.00 = EXISTING GRADE Ary�o C>>•o�7 ° . A
NOTES:
LOT GRADING TYPE = A LOT 45 0 00 J \ a ao yA A�
PROPOSED PAD ELEVATION = %y�\
FRONT SETBACK = 20' 296.•'� v°• o0o J�yCP . . 0
SIDE SETBACK = 10' Gj1 4 \ (F o
REAR SETBACK = 10\ 6<k�6 °°'. ' �� °0< 0. € �Z�n \�
\ N ° Q° \ �: \ aJv
\ \016p ` o d HO * oo
2O Ji\
PLAT F ono �yd
BOUNDARY \ c��c2 y�y o14
� 2a'..•''
Lb
0.
0
01. LOT 46 bt;
0
.� '•\ off' 00
ZL y`° f r�{ 110 BOUNDARY
�O \. •O LOT 47
a
\ \N
TRACT "K" \ \
HIDDEN RIVER PHASE ONE A
(PLAT BOOK 74, PAGES 101-121)
LANDSCAPE & \
BUFER EASEMENT
PROPOSED:
LOWEST FLOOR ELEVATIONS:
LIVING AREA: 72.35'
DESCRIPTION: ELEVATIONS
AREA: 71.81'
ELEVATIONS REFERENCED TO
LOT 46, MAP OR PLAT ENTITLED "HIDDEN RIVER PHASE ONE B", NATIONAL GEODETIC VERTICAL
AS RECORDED IN PLAT BOOK ___, PAGES ___ THROUGH , DATUM OF 1929. MEAN SEA
OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. LEVEL= 00.00 FT.
APPARENT FLOOD HAZARD ZONE: 'Y' COMMUNITY PANEL NO. 120230 0460 D EFFECTIVE DATE: 9/30/1992
LEGEND:
(C)= CALCULATED DATA, (D)= DEED DATA, (M)= MEASURED DATA, (P)= PLAT DATA, rt= CENTERLINE, A/C= AIR CONDITIONER, B/C= BACK OF CURB, C/S=
CONCRETE SLAB, CH= CHORD, CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= COVERED, E/P= EDGE OF PAVEMENT, ESM'T= EASEMENT,
F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE, FIR= FOUND IRON ROD, FN&D= FOUND NAIL & DISK, FPP= FOUND PINCHED
PIPE, LFE= LOWEST FLOOR ELEVATION, MAS.= MASONRY, OR= OFFICIAL RECORD BOOK, PB= PLAT BOOK, PCP= PERMANENT CONTROL POINT, PRM= PERMANENT
REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & CAP No. 4493, SN&D= SET NAIL & DISK, TBM= TEMPORARY BENCHMARK,
U P= UTILITY POLE, W F= WOOD FENCE, R = RADIAL
JOHN R.BEACH&ASSOCIATES,INC. Drawn By: SMS Square Feet: 6600.00 t LENNAR HOMES
t 0 SURVEYORS AND MAPPERS Checked By:
911 WEST ST. PETERSBURG DRIVE JRB
ONE OLDSMAR, FLORIDA 34677
WAY (813) 854-1276 FAX (813) 855-8370 Scale: 1"=30'
NOT VALID WITHOUT THE SIGNATURE AND Date of Survey: 03ZZ
THE ORIGINAL RAISED SEAL OF A FLORIDA PLOT PLAN 03/21/2018 RTM dbHN .BEACH DATE
LICENSED SURVEYOR AND MAPPER 00FLORIDA KC. LAND SURVEYOR No. 2984 LB 4493
Revisions:
813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021
Building Department
Date Received MAT U J Z018 Phone Contact for Perm itti nq 813 363 2891
L H . . . . . . . . . . . . .
ennar omes,LLC .574.5700
Owner's Name Owner Phone Number 813
Owner's Address 4600 W.Cypress St.Ste.260,Tampa,FL 33607 owner Phone Number
Fee Simple Titleholder Name I N/A Owner Phone Number
Fee Simple Titleholder Address N/A
JOB ADDRESS [3051 Moulden Hollow Drive LOT# 0460
SUBDIVISION Hidden River Phase One A PARCEL ID# 24-26-21-01 00-0000&-.0460
(OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED II II NEW CONSTR 8 ADD/ALT SIGN Q Q DEMOLISH
INSTALL REPAIR
PROPOSED USE SFR Q COMM OTHER
TYPE OF CONSTRUCTION BLOCK Q FRAME STEEL
DESCRIPTION OF WORK Single Family Residence/Pool/Screen Enclosure Fence
BUILDING SIZE I U/R IF 2376 SQ FOOTAGE1936 HEIGHT 1 StOrY
.0BUILDING VALUATION OF TOTAL CONSTRUCTION
r-71
YJELECTRICAL 1$ l
7 AMP SERVICE FX_� PROGRESS ENERGY W.R.E.C.
PLUMBING 1$
F07I MECHANICAL 1$ VALUATION OF MECHANICAL INSTALLATION
y f
=GAS ROOFING Q SPECIALTY OTHER
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA DYES Do
ff & 102211 1 . . . . . . . . . . . . . . Reffummus . . . . . . . . . . . . . . . . . . .
- - - - - - - - - - - - - - - • - - - -
BUILDER COMPANY I Lermar Homes,LLC
SIGNATURE REGISTERED Y N FEE CURREN LILN�j
Address4604 Cypresf*8t.Ste.200,Tampa,FL 33607 License# I CGC1518166
ELECTRICIAN t COMPANY =Edmonson Electric, Inc.
SIGNATURE REGISTERED I Y/ N I EFFrl]RRFN
pedwels jo palulid 1p9dAj AjBION 40 9w2N PgawBls Jo 1391UPa'PaqAl kIBION 10 awON
U10.IaUOH-W 10SSTIH uplaROI-1-W 108SIM
'IN 111s1IWW2D LC586dd 'ON uOISs1wwO0
ollqnd/UeION oilqnd fJBION :=5
uopeolltluapl se U0119041juepl se
paGnp4wd'9A134181339 10 OW 01 uMOUX Alleuosied GJ8/sl OLIA pagnpeld aike14/settio aw 01 umou�Alleuosiad aje/sl oL[AA
BL-AV-09 Aq
smi aw ajoisa(1)9=112 JO)01 1 LihAk.q mip nmrmnennc ��� o I"jdw-no
-- l
NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed" restrictions"
which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any
applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or
contractors'to undertake work, they may be required to be licensed in accordance with state and local regulations. If the
contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation
under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for-the
intended work, they are advised to,contact the Pasco County Building Inspection Division—Licensing Section at 727-847-
8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign
portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the
contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco
County.
TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of
use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and
90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of
permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to
receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or
final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact
fees are due, they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I
certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's
Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone
other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to
deliver it to the"owner" prior to commencement.
CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work
will be,done in compliance with-all applicable laws regulating construction, zoning and land development. Application is
hereby made to obtain a permit to do work and installation as indicated. I certify that.no work or installation has
commenced prior to-issuance of a permit and that all work will be performed to meet standards of all laws regulating
construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also
certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is
my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to:
- Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands, Water/Waistewater Treatment.
- Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering
Watercourses.
- Army Corps of Engineers-Seawalls, Docks, Navigable Waterways.
- Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment,
Septic Tanks.
- US Environmental Protection Agency-Asbestos abatement.
- Federal Aviation Authority-Runways.
I understand that the following-restrictions apply to the use of fill:
- Use of fill is not allowed in Flood Zone W" unless expressly permitted.
- If the fill material is-to be used in Flood Zone "A", it is understood that a drainage plan addressing a
"compensating volume" will be submitted at time of permitting which is prepared by a professional engineer
licensed by_the State of Florida.
- If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall
construction, I certify that fill will be used only to fill the area within the stem wall.
- If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating
the conditions of the.building permit issued under the attached permit application, for lots less than one (1)
acre which are elevatod by.fill, an engineered drainage plan is required.
If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in
this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work,
plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A
permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or
set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter
requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid
unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by
the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension
may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate
justifiable cause for the extension. If work ceases for ninety(90) consecutive days,the job is considered abandoned.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
FLORIDA JURAT(F.S.117.03)
PASCO COUNTY
RA S C DEVELOPMENT SERVICES
8731 Citizens Drive Date:8/7/2018
COUNTY New Port Richey, FL 34654
Oi4 SFAEE. --727-847--2411—
A
Nut"T 1-1� PERMIT
Receipt#.: 1782456
FEE DESCRIPTION ACCOUNT CODE UNITS INVOICE# FEE AMOUNT PAID RECEIPT# DATE
Impact Fee Residential Solid 25.50 1372010 $25.50 $25.50 1.782456 8/7/18
Waste Single Family
3051 MOULDEN HOLLOW DR.
TOTALS: $25.50 $26.50
Receipt Paid By Check# CC Auth# Cashier ID, Workstation Receipt Date Amt Paid
11782458 Check 01029749 554 BCCCP58W 08/07/2018 $25.50
Total Payments: $25.50
Pavor Address Phone
LENNAR HOMES LLC
Comments:
3051 MOULDEN HOLLOW DR
While you will be paying your bill with Pasco County DdVelopmerit Services,the full amount of the credit mcl or ewcheck fees,NOT shown above,Is 6olikted by
First Billing payment seryle s.
0289.5856 Lcnnar.Hotnes,LLC JP,Morgan Chase Bank N.A. STUB CHECKNO. 1029749
900060.10110.114 1 of -1 DATE 08/01/18
-1JVJ,'0fi7E.
CO.# NUMBER DATE PAYMENTAD1110E GROSS DISCOUNT' -N&
07271 15114720046.401435 072418 15174720046,401435 $25.50 -.$0.00 $25.50
goo
ro
lot
J
1517150 Pasco County SOCC 7530 Little on
Port Richey FL 33553-0000 $2S.50 $0.00 $25.501
MyRepoqs/repotts//PASCOPROD/PASCO/ReceiptPOS V6.rpi E10/201 8 -Page 1 of 1
5335 - 8TH STREET
(813)780-0020
CERTIFICATE OF OCCUPANCY
Address: 3051 MOULDEN HOLLOW DR Owner: LENNAR HOMES LLC
ZEPHYRHILLS, FL. 4600 W CYPRESS ST STE 200
Subdiv: HIDDEN RIVER TAMPA FL 33607-4099
Parcel: 24-26-21-0100-00000-0460 Work Type: 101-NEW CONST/SFR
Construction Type: NOT APPLICABLE ❑ Sprinklers
Use Classification: NOT APPLICABLE
Permit Number: 19807
Dan,d 0 10/18/2018
ISS BY: BUILDI OFFICIAL :
WATER MUST BE CHANGED OVER WITHIN 10 DAYS OF ISSUANCE
GARBAGE DEPOSIT MUST BE APPLIED. FOR PRIOR TO ISSUANCE