Permit#:19810 Issued: 6/25/2018 Address: 3123 KRESTERBROOKE LANE
Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL.
Class of Work: 101-NEW CONST/SFR Township: Range:
Proposed Use: NOT APPLICABLE Lot(s): Block: Section:
Sq. Feet: Est. Value: Book: Page:
Cost: 256,391.40 Total Fees: 17,790.47 Subdivision: HIDDEN RIVER
Amount Paid: 17,790.47 Date Paid: 6/25/2018 Parcel Number: 24-26-21-0100-00000-1170
CONTRACTOR INFORMATION OWNER INFORMATION
Name: LENNAR HOMES LLC Name: LENNAR HOMES LLC
Addr: 4600 W. CYPRESS ST STE 200 Address: 4600 W CYPRESS ST STE 200
TAMPA, FL. 33607 TAMPA, FL 33607-4099
Phone: (813)574-5743 Lic: Phone: 813-574-5700
Work Desc: CONSTRUCT SINGLE FAMILY 2,276 SQ FT
APPLICATION FEES
BUILDING FEE 1,426.49 ELECTRICAL FEE 298.13 PLUMBING FEE 198.75
MECHANICAL FEE 139.13 SEWER CONNECTION RESIDEW 2,090.00 WATER CONNECTION RESIDENT 1,010.00
WATER METER RES 3/4" 473.78 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00
PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE NEW 7,128.00
SCHOOL-SFR NEW 1% 71.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32
I rkw
Ins ections'Re uired
FOOTER 2ND ROUGH PLUMB Misc INSULATION CEILING
FOOTER BOND DUCTS INSULATED SEWER MISC.
ROUGH ELECTRIC LINTEL MISC MISC.
1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC.
DUCTS INSTALLED WATER MISC DRIVEWAY
PRE-SLAB SHEATHING MISC. MISC.
CONSTRUCTION POLE FRAME MISC. MISC.
REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES:
NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing, consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans,Specifications and Must Accompany Application. All work shall be performed in accordance
with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
CONTRACTORS SIGNATURE PERMIT OFFI
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
813-780-0020 City of Zephyrhills Permit Application Fax-613-780-0021
Building Department .
Date Received MAY 0 3 2"' Phone Contact for Permitting 813 363 2891
LLC Ho
mes,omes,
Owner's Name L Owner Phone Number 813.574.5700
4600 W.Cypress St.Ste,200,Tampa,FL 33607
Owner's Address Owner Phone Number F
Fee Simple Titleholder Name I N/A Owner Phone Number
Fee Simple Titleholder. Address N/A
JOB ADDRESS 3123
Kresterbrooke Lane LOT# 1170
SUBDIVISION Hidden River Phase One A PARCEL ID# 24-26-21-0100-00000-1170
(OBTAINED FROM PROPERTY TAX NOTICE)
WORK PROPOSED 07 NEW CONSTRR ADD/ALT Q SIGN Q Q DEMOLISH
INSTALL REPAIR
PROPOSED USE SFR Q COMM OTHER
TYPE OF CONSTRUCTION BLOCK Q FRAME STEEL
DESCRIPTION OF WORK
Single Family Residence Pool/Screen Enclosure/Fence
I
BUILDING SIZE I U/R SF 2276 7 SQTOOTAGE 181 HEIGHT I Story
a - a a a a a a
.0BUILDING VALUATION OF TOTAL CONSTRUCTION
F171 ELECTRICAL 1$ AMP SERVICE F5(-1 PROGRESS ENERGY W.R.E.C.
PLUMBING 1$
WIMECHANICAL $ VALUATION OF MECHANICAL INSTALLATION
=GAS F ROOFING Q SPECIALTY OTHER v/
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA EIYES Do
■. . . . . . . . . . . . . . ..
BUILDER COMPANY Lennar Homes,LLC
I
SIGNATURE REGISTERED Y/ N FEE CURREN
Address 4600 W.Cypress St.Ste.-200,Tampa,FL 33607
— I License# [7EGC1518166
ELECTRICIAN COMPANY I Edmonson-Ele-c-tric, Inc.•
SIGNATURE 0 REGISTERED Y/ N FEE CURREN
Address 1034 Skipper Road,Tampa, FL 33613 License# FEC13005408
PLUMBER COMPANY JBayonet Plumbing, Heating &AC, Inc
SIGNATURE REGISTERED Y/ N FEE CURREN
Address I—PO, Box 5308, Bayonet, FL 34674-5308 License# I CFC042998
MECHANICAL co mpANy Bayonet Plumbing, Heating &AC, Inc
SIGNATURE 1 0 REGISTERED Y/ N i FEE CURREN LILN_�J
Address P.O. Box 53091,'-Bayonet, FL 34674-5308 License# I CAC058062
OTHER COMPANY
SIGNATURE V REGISTERED Y/ N FEE CURREN
Address F42711 Shoal Line Blvd, Spring Hill, FL 34607 License# F97676-057991
11111111111111111111111111111111111111111111111111111 .11111111111111
RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction,
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans wl Silt Fence installed;
Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects
COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction.
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans wl Silt Fence Installed,,
Sanitary Facilities&I dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance
SIGN PERMIT Attach(2)sets of Engineered Plans.
****PROPERTY SURVEY required for all NEW construction.
. . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Directions,
Fill out application completely.
Owner&Contractor sign back of application,notarized
If over$2500,a Notice of Commencement is required. (AIC upgrades over$7500)
Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (copy of contract required)
Reroofs if shingles Sewers Service Upgrades AtC Fences(Plot/Survey/Footage)
Driveways-Not over Counter if on public roadways..needs ROW
NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed" restrictions"
which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any
applicable deed restrictions.
UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or
contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the
contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation
under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the
intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847-
8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign
portions of.the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the
contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco
County.
TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of
use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and
90-07, as amended. The undersigned also understands, that such fees, as may be due, will be identified at the time of
permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to
receiving a "certificate of occupancy" or final power release. If the project does not involve a certificate of occupancy or
final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact
fees are due, they must be paid..prior to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is$2,500.00 or more, I
certify that I, the applicant, have- been provided with a copy of the "Florida Construction Lien Law—Homeowner's
Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone
other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to
deliver it to the"owner" prior to-commencement.
CONTRACTOR'S/OWNER'S.AFFIDAVIT: I certify that all the information in this application is accurate and that all work
will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is
hereby made to obtain a permit-to do work and installation as indicated. I certify that no work or installation has
commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating
construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also
certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is
my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to:
- Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands, WaterMlastewater Treatment.
- Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering
Watercourses,
- Army Corps of Engineers-Seawalls, Docks, Navigable Waterways.
- Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment,
Septic Tanks.
- US Environmental Protection Agency-Asbestos abatement.
Federal Aviation Authority-Runways.
I understand that the following restrictions apply to the Use of fill:
- Use of fill is not allowed in Flood Zone W" unless expressly permitted.
- If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a
"compensating volume" will be submitted at time of permitting which is prepared by a professional engineer
licensed by the State of Florida.
- If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall
construction, I certify that fill will be used only to fill the area within the stem wall.
- If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating
the conditions of the building permit issued under the attached permit application, for lots less than one (1)
acre which are elevated by fill, an engineered drainage plan is required.
If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in
this affidavit prior to commencing.construction. I understand that a separate permit may be required for electrical work,
plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A
permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or
set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter
requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid
unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by
the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension
may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate
justifiable cause for the extension. If work ceases for ninety(90) consecutive days, the job is considered abandoned.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
FLORIDA JURAT(F.S.117.03)
OWNER OR AGENT CONTRACTOR
Subscribed and sworn to(or.affirm fore met ' Subscribed and sworn to(or affir d before me-this I
3U-Hpf-1O by E� L 30-AP110 b 6- �J
Y
Who is/are personally known to me or hasihave predused- Who is/are personally known to me or has/have predue
ntification. as identification.
Notary Public Notary Public
Commission No. FF98537 Commission No. F98537
Elissa M.Holleran Elissa M.Holleran
Name of Notary tvped,printed or stamped Name of Notary typed,printed or stamped
lwff
t.11�lll_�IN'
y4''P0WNT• µ1,I41rdwW nivillpO4aB4r
.. l9�ida3tN'F.soXrals.UP1�9�iIM�lM�pll Bnhdil'Iha'h'fyF�la4s,onla�al4i5147g111
1
Lennar Homes-3123 Kresterbrooke Ln-2,276 sq ft
Column ts
SQ. FEET PRICE
MAIN OR LIVING: 2,276 $ 112.65
OTHER AREA UNDER ROOF: $ 88.00
OTHER: - $ -
VALUATION $ 256,391.40
FEE SHEET $ 1,325.00
ADDRESS $ 40.00
DRIVEWAY1 $ 40.00
I
BUILDING: $ 1,431.50
ELECTRICAL: $ 298.13
PLUMBING: $ 198.75
MECHANICAL: $ 139.13
SUB-TOTAL $ 2,067.50
TOTAL $ 2,067.50
SEWER: $ 2,090.00 n/a
WATER: $ 1,010.00 n/a
IRRIGATION: $ -
TOTAL: $ 3,100.00
WATER METER: $ 473.78 n/a
IRRIGATION METER $ -
FIRE DEPARTMENT FEES
PLANS TOTAL: n/a
INSPECTION TOTAL:
PERMIT TOTAL
TOTAL: $ -
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
FIRE $ 273.00
5% $ 26.35
TOTAL: $ 553.35
SUB-TOTAL $ 6-1194.63
PARK IMPACT FEES $ 769.56
SIF'S: $ 7,128.00
100.0% $ 7,128.00
$ 71.28
TOTAL: $ 7,199.28
T I F'S: $ 3,632.00
99% $ 3,595.68
1% $ 36.32
TOTAL: $ 17,795.47
,
Sin le. Tamil Dwelln
g Y g
Pl
an Review.Comments
1: F.F.E. shall be;a.minirnum:of.8- above.the road.elevation and an' engineered site plan.
2. Lots shall,be graded to-cornply with R401.3 of the F.B:.C: .:
- .3. .Compaction test required.if 24"or more.of fill dirt is.btought in at any one place: -
4. :Tie iri survey-required before pouring concrete.:
5. Driveways require a R.0M. use permit:: All 4:sides of.driveway thru the sidewalk shall have.
expansion material.
6. All setbacks shall.be met.:.
7.: All.property:markers shall be.uricovered and marked at time of first.inspection.
8: All A.D.A. requirements shall be met.:.
9.: No:electric lumbin p g, mechanical; or framing shall be:covered without an.inspection and
approval first.
-
10.All Garages shall-comply:.with:section R302:6.of,the.F:B:C::(Fire Separation).
I.I.Appliances shall not_be installed in:a locationwhere subiectto mechanical-darnage unless.
:protected'by approved barriers. M303:4 o£the F.B:C
12. Water heaters shall comply with secti6nT607.3 of the F.B.C:
13. Foundation supports for.A/C.units.shall be raised at least 3" above finished grade.' M 13 08.1.
-14. Return air in a11.bedrooms..F.B.C. ,M1620.4.-
15: Smoke detectors are to be installed:in accordance-with R313:1 of-the F.B.C.
16,.All glazing requirements are-to be in accordance with R308.4,of the.F.B.C. .
17. All means.of egress are to.be in:accordance with R31 Yof the F.A.C.
18. `.`Green gypsum board"shall riot be used:as.a backer in showers or tubs. R702.4.2.F.B.C.
19. Combination-type AFCI breakers arerequired:at all.locations re 'an AFCI type breaker.
20. Catbon monoxide.alarms-will required in new-construction that uses fossil-burning heating
or appliances or an attached garage. They shall be.installed in accordance with the F,B.C:
21. All plumbing,mechanical,:and:electrical shall separate from unit.to:unit: This includes all,
underground plumbingarid electric:
22.-All 2011:N:E:C: Codes-will.be enforced:
23.Tainper-Resistant Receptacles in accordance with 406:11 of the 2011 N:E:C
.24: In accordance:-with the band:Development:Code,-lots shall be sodded before final-at least-10. .
feet.:around the structure.
25.A.cony of the energy cacls shall be with:permit at all times.
26 Cony of final insulation report shall be.nt�ovided with permit before finab
RRE.-Finished Floor Elevation
F.B.C- Florida Building Code Oh Edition::
R.O.W-Right of Way.
A.D.A.-Americans with Disabilities Act . N.E.C.-National Electric.Code(2011)
.y
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: 1791A1 sf ADS Carrier Builder Name: Lennar Homes
Street: 3123 Kresterbrooke Lane Permit Office: C�ty�o/,Zephyrhills
City,State,Zip: FL, Permit Number: Gb6jj
Owner: Lennar Homes Jurisdiction: 61 00
Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(1572.7 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1241.30 ft2
b.Frame-Wood,Adjacent R=11.0 331.33 ft2
3. Number of units,if multiple family 1 c.N/A
R= ft2
4. Number of Bedrooms 4 d.N/A R= ft2
5. Is this a worst case? Yes 10.Ceiling Types (1817.0 sqft.) Insulation Area
a.Under Attic(Vented) R=30.0 1817.00 ft2
6. Conditioned floor area above grade(ft2) 1817 b.N/A R= ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ft2
11.Ducts R ft2
7. Windows(143.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 363.4
a. U-Factor. Dbl,U=0.54 87.00 ft2
SHGC: SHGC=0.31
b. U-Factor: Dbl,U=0.56 33.33 ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.32 a.Central Unit 28.4 SEER:15.00
c. U-Factor: Dbl,U=0.56 23.00 ft2
SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency
d. U-Factor. N/A ft2 a.Electric Heat Pump 28.2 HSPF:8.50
SHGC:
Area Weighted Average Overhanb Depth: 1.233 ft.
Area Weighted Average SHGC: 0.308 14.Hot water systems
8. Floor Types (1817.0 sqft.) Insulation Area a.Electric Cap:40 gallons
a.Slab-On-Grade Edge Insulation R=0.0 1817.00 ft2 b. Conservation features _ EF:0.950
b.N/A R= ft2 None
c.N/A R= ft2 15.Credits Pstat
Glass/Floor Area: 0.079 Total Proposed Modified Loads: 58.26 PASS
Total Baseline Loads: 58.15
1 hereby certify that the plans and specifications covered by Review of the plans and � ''013'S.-r
this calculation are in compliance with the Florida Energy specifications covered by this
Code. calculation indicates compliance � ;r,�,f''' `_' ;�.�. +.
Dave /��G/ with the Florida Energy Code. �+ rqr, '��,:•' �,�; „
PREPARED BY: Before construction is completed
YG
DATE: this building will be inspected for ( �
compliance with Section 553.908
hereby certify that this building,as designed, is in compliance Florida Statutes. '
with the Florida Energy Code.
?G,OD �
OWNER/AG MAY 0 3 2018
ENT: BUILDING OF ICI L:
DATE: DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house.
5/1/2018 10:06 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 4
' I
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: 1791A1 sf ADS Carrier Builder Name: Lennar Homes
Street: 3123 Kresterbrooke Lane Permit Office: City of Zephyrhills
City,State,Zip: FL, Permit Number: I
Owner: Lennar Homes ,jurisdiction: 611600
Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(1572.7 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1241.30 ftZ
b.Frame-Wood,Adjacent R=11.0 331.33 ft2
3. Number of units,if multiple family 1 c.N/A R= ft2
I.
4. Number of Bedrooms 4 d.N/A R= ft2
5. Is this a worst case? Yes 10.Ceiling Types (1817.0 sqft.) Insulation Area
a.Under Attic(Vented) R=30.0 1817.00 ft2
6. Conditioned floor area above grade(ft21 1817 b.N/A R= ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ft2
11.Ducts R ft2
7. Windows(143.3 sqft,) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 363.4
a. U-Factor: Dbl,U=0.54 87.00 ft2
SHGC: SHGC=0.31
b. U-Factor: Dbl,U=0.56 33.33 ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.32 a.Central Unit 28.4 SEER:15.00
c. U-Factor: Dbl,U=0.56 23.00 ft2
SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a.Electric Heat Pump 28.2 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 1.233 ft.
Area Weighted Average SHGC: 0.308 14.Hot water systems
8. Floor Types (1817.0 sqft.) Insulation Area a.Electric Cap:40 gallons
EF:0.950
a.Slab-On-Grade Edge Insulation R=0.0 1817.00 ft2 b. Conservation features
b.N/A R= ft2 None
c.N/A R= ft2 15.Credits Pstat
Glass/Floor Area: 0.079 Total Proposed Modified Loads: 58.26 PASS
Total Baseline Loads: 58.15
I hereby certify that the plans and specifications covered by Review of the plans andZ_ k1E ST ��
this calculation are in compliance with the Florida Energy specifications covered by this ��
Code. calculation indicates compliance
D /✓�G with the Florida Energy Code.ave
PREPARED BY: AG[rl h Before constructiod is completed , "' ►.
DATE: r this building will belinspected for
compliance with Section 553.908
I hereby certify that this building,as designed, is in compliance Florida Statutes. ra, ,
with the Florida Energy Code.
OWNER/AGENT: MAY 0 3 2010 BUILDING OFFICIAL:
DATE: DATE:
- Compliance requires certification by the air handler unit manufacturer that the airi handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R4102.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage�to outdoors,
tested in accordance with ANSI/RESNET/ICC 380,is not greater than 0.030 Qn for whole house.
I
5/1/2018 10:06 AM EnergyGaugeO USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 4
i
I
FORM R405-2017 =
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: 1791A1 sf ADS Carrier Builder Name: Lennar Homes
Street: 3123 Kresterbrooke Lane Permit Office: City of Zephyrhills
City,State,Zip: FL, Permit Number:
Owner: Lennar Homes Jurisdiction: 611600
Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2)
1. New construction or existing New(From Plans) 9. Wall Types(1572.7 sqft.) Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1241.30 ft2
b.Frame-Wood,Adjacent R=11.0 331.33 ft2
3. Number of units,if multiple family 1 c.N/A
R= ft2
4. Number of Bedrooms 4 d.N/A R= ft2
10.Ceiling Types (1817.0 sqft.) Insulation Area
5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1817.00 ft2
6. Conditioned floor area above grade(ft2) 1817 b.N/A R= ft2
Conditioned floor area below grade(ft2) 0 c.N/A R= ft2
11.Ducts R ft2
7. Windows(143.3 sqft.) Description Area a.Sup:Attic,Ret:Main,AH:Main 6 363.4
a. U-Factor: Dbl,U=0.54 87.00 ft2
SHGC: SHGC=0.31
b. U-Factor: Dbl,U=0.56 33.33 ft2 12.Cooling systems kBtu/hr Efficiency
SHGC: SHGC=0.32 a.Central Unit 28.4 SEER:15.00
c. U-Factor: Dbl,U=0.56 23.00 ft2
SHGC: SHGC=0.28 13.Heating systems kBtu/hr Efficiency
d. U-Factor: N/A ft2 a.Electric Heat Pump 28.2 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 1.233 ft.
Area Weighted Average SHGC: 0.308 14.Hot water systems
8. Floor Types (1817.0 sg a.Electric Cap:40 gallonsft.) Insulation Area EF:0.950
a.Slab-On-Grade Edge Insulation R=0.0 1817.00 ft2 b. Conservation features
b.N/A R= ft2 None
c.N/A R= ft2 15.Credits Pstat
Glass/Floor Area: 0.079
Total Proposed Modified Loads: 58.26 PASS
Total Baseline Loads: 58.15
hereby certify that the plans and specifications covered by Review of the plans and
this calculation are in compliance with the Florida Energy specifications covered by thisOf
Code. / calculation indicates compliance
DaveG�IYtG�I with the Florida Energy Code. ruri =� ti
PREPARED BY: Before construction is completed
DATE: this building will be inspected for
compliance with Section 553.908
I hereby certify that this building,as designed, is in compliance Florida Statutes.
with the Florida Energy Code.
MAY 0 3 2018 ..
OWNER/AGENT: BUILDING OFF IAL:
DATE: DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory-sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2).
- Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors,
tested in accordance with ANSI/RESNET/ICC 380, is not greater than 0.030 Qn for whole house.
5/1/2018 10:06 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 4
FORM R405-2017
PROJECT"
Title: 1791A1 sf ADS Carrier Bedrooms: 4 Address Type: Street Address
Building Type: User Conditioned Area: 1817 Lot#
Owner Name: Lennar Homes Total Stories: 1 Block/Subdivision:
#of Units: 1 Worst Case: Yes a PlatBook:
Builder Name: Lennar Homes Rotate Angle: 45 n Street:
Permit Office: Cross Ventilation: County: Pasco
Jurisdiction: Whole House Fan: City,State,Zip: ,
Family Type: Single-family FL,
New/Existing: New(From Plans)
Comment: FBC 2017
CLIMATE
/ Design Temp Int Design Temp Heating Design Daily Temp
V Design Location TMY Site 97.5% 2.5% Winter Summer Degree Days Moisture Range
FL,Tampa FL_TAMPA INTERNATI 39 91 70 75 645.5 54 Medium
BLOCKS
Number Name Area Volume
1 Block1 1817 14536
SPACES
Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated
1 Main 1817 14536 Yes 5 4 1 Yes Yes Yes
FLOORS
# Floor Type Space Perimeter R-Value Area Tile Wood Carpet
1 Slab-On-Grade Edge Insulatio Main 155 ft 0 1817 ft2 0.3 0 0.7
ROOF
/ Roof Gable Roof Solar SA Emitt Emitt Deck Pitch
# Type Materials Area Area Color Absor. Tested Tested Insul. (deg)
1 Hip Composition shingles 1968 ft2 0 ft2 Medium 0.85 No 0.9 No 0 22.6
ATTIC
V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC
1 Full attic Vented 300 1817 ft2 N N
CEILING
# Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type
1 Under Attic(Vented) Main 30 Blown 1817 ft2 0.11 Wood
5/1/2018 10:06 AM EnergyGaugeO USA-FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 4
r
FORM R405-2017
WALLS
Adjacent Space Cavity Width Height Sheathing Framing Solar Below
_ 1 N=>NE Exterior Concrete Block-Int Insul Main 4.0999 19 6 8 156.0 ft2 0 0.600000 0
_ 2 N=>NE Garage Frame-Wood Main 11 20 8 8 165.3 ft2 0 0.01 0
3 W=>NW Garage Frame-Wood Main 11 20 9 8 166.0 ft2 0 0.01 0
4 E=>SE Exterior Concrete Block-Int Insul Main 4.0999 58 8 464.0 ft2 0 0.600000 0
5 S=>SW Exterior Concrete Block-Int Insul Main 4.0999 34 8 272.0 ft2 0 0.600000 0
_ 6 W=>NW Exterior Concrete Block-Int Insul Main 4.0999 37 8 8 301.3 ft2 0 0.600000 0
7 S=>SW Exterior Concrete Block-Int Insul Main 4.0999 6 8 48.0 ft2 0 0.600000 0
DOORS
# Ornt Door Type Space Storms U-Value Width Height Area
Ft In Ft In
1 N=>NE Insulated Main None .2 3 6 8 20 ft2
2 N=>NE Wood Main None .4 2 8 6 8 17.8 ft2
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
/ Wall Overhang
V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening
1 N=>NE 1 Metal Low-E Double Yes 0.56 0.28 N 23.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds None
2 E=>SE 4 Metal Low-E Double Yes 0.54 0.31 N 32.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds None
3 S=>SW 5 Metal Low-E Double Yes 0.54 0.31 N 32.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds None
4 S=>SW 7 Metal Low-E Double Yes 0.56 0.32 N 33.3 ft2 2 ft 0 in 0 ft 4 in Drapes/blinds None
5 W=>NW 6 Metal Low-E Double Yes 0.54 0.31 N 23.0 ft2 1 ft 0 in 0 ft 10 in Drapes/blinds None
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation
1 427 ft2 427 ft2 42 ft 8 ft 1
INFILTRATION
# Scope Method SLA CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000356 1695.9 93.1 175.09 .2669 7
HEATING SYSTEM
# System Type Subtype Efficiency Capacity Block Ducts
1 Electric Heat Pump/ None HSPF:8.5 28.2 kBtu/hr 1 sys#1
5/1/2018 10:06 AM EnergyGaugeO USA-FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 4
FORM R405-2017
COOLING SYSTEM
# System Type Subtype Effigiency Capacity Air Flow SHR Block Ducts
1 Central Unit/ Split SEER:15 28.4 kBtu/hr 852 cfm 0.85 1 sys#1
HOT WATER SYSTEM
# System Type SubType Location EF Cap Use SetPnt Conservation
1 Electric None Garage 0.95 40 gal 70 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC Collector Storage
Cart # Company Name System Model# Collector Model# Area Volume FEF
None None ftz
DUCTS
—Supply— —Return— Air CFM 25 CFM25 HVAC#
V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1 Attic 6 363.4 ft Main 90.85 ft Proposed Qn Main —cfm 54.5 cfm 0.03 0.60 1 1
TEMPERATURES
Programable Thermostat:Y Ceiling Fans:
CoolingJan [[ ]]Feb [[ ]]Mar A r Ma rj Jun Jul rj Au ri Se Oct Nov Dec
Heatin Jan [X]Feb [X]Mar E j Apr j
j MaY Jun rj Jul Au Sep Oct H
Nov Dec
Ventin Jan [[ ]]Feb [[XX]]Mar [X A r May Jun Jul Aug Se [X Oct Nov Dec
Thermostat Schedule: HERS 2006 Reference Hours
Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12
Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80
PM 80 80 78 78 78 78 78 78 78 78 78 78
Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78
PM 78 78 78 78 78 78 78 78 78 78 78 78
Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68
PM 68 68 68 68 68 68 68 68 68 68 66 66
5/1/2018 10:06 AM EnergyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 4
FORM R405-2017
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
- ESTIMATED ENERGY PERFORMANCE INDEX* = 100
The lower the EnergyPerformance Index, the more efficient the home.
FL,
1. New construction or existing New(From Plans) 9. Wall Types Insulation Area
2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 1241.30 ft2
b.Frame-Wood,Adjacent R=11.0 331.33 ft2
3. Number of units,if multiple family 1 c.N/A R= ft2
4. Number of Bedrooms 4 d.N/A R= ft2
10.Ceiling Types Insulation Area
5. Is this a worst case? Yes a.Under Attic(Vented) R=30.0 1817.00 ft2
6. Conditioned floor area(ft2) 1817 b.N/A R= ft2
7. Windows" Description Area c.N/A R= ft2
a. U-Factor: Dbl, U=0.54 87.00 ft2 11.Ducts R ft2
SHGC: SHGC=0.31 a.Sup:Attic,Ret:Main,AH:Main 6 363.4
b. U-Factor: Dbl,U=0.56 33.33 ft2
SHGC: SHGC=0.32 12.Cooling systems kBtu/hr Efficiency
c. U-Factor: Dbl,U=0.56 23.00 ft2 a.Central Unit 28.4 SEER:15.00
SHGC: SHGC=0.28
d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency
SHGC: a.Electric Heat Pump 28.2 HSPF:8.50
Area Weighted Average Overhang Depth: 1.233 ft.
Area Weighted Average SHGC: 0.308
8. Floor Types Insulation Area 14.Hot water systems
a.Electric Cap:40 gallons
a.Slab-On-Grade Edge Insulation R=0.0 1817.00 ft2EF:0.95
b.N/A R= ft2
c.N/A R= ft2 b. Conservation features
None
15.Credits Pstat
certify that this home has complied with the Florida Energy Efficiency Code for Building
vas
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
ti°'% ~�a`Ovs+,
based on installed Code compliant feat S. a " .'' ��
Builder Signature: Date:
05/02/18
Address of New Home: 3123 Kresterbrooke Lane City/FL Zip:Zephyrhills,FL 33540 .:
�p yyE'CiL
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage(EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at
techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of
certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building
Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
5/1/2018 10:07 AM EnergyGauge®USA-FlaRes2017 -Section R405.4.1 Compliant Software Page 1 of 1
BuildingAnalysis Job: 1791A1 sf ADS
Y Date: 5/1/2018
Entire House By: Dave
Bayonet Plumbing Heating and Air
Project Information
For: Lennar Homes
Design Conditions
Location: Indoor: Heating Cooling
Tampa International AP, FL, US Indoor temperature(OF) 70 75
Elevation: 10 ft Design TD (OF) 39 16
Latitude: 28°N Relative humidity (%) 50 50
Outdoor: Heating Cooling Moisture difference(gr/lb) 34.7 54.7
Dry bulb(OF) 31 91 Infiltration:
Daily range(OF) - 14 ( L ) Method Simplified
Wet bulb(OF) - 77 Construction quality Semi-tight
Wind speed (mph) 15.0 7.5 Fireplaces 0
Component Btuh/ft2 Btuh % of load
Walls 5.6 6465 24.9 acts
Glazing 30.2 5116 19.7 wall
Doors 23.5 466 1.8 Infiltration
Ceilings 1.3 2271 8.8
Floors 3.4 6125 23.6
Infiltration 2.2 2887 11.1
Ducts 2616 10.1
Piping 0 0 Glazing Floors
Humidification 0 0
Ventilation 0 0 Other Ceilings
Adjustments 0
Total 259471. 100.0
Component Btuh/ft2- Btuh % of load
Walls 2.8 3216 14.4 walls Internal Gains
Glazing 47.3 8025 35.9
Doors 18.4 365 1.6
Ceilings 1.7 3140 14.0
Floors 0 0 0
Infiltration 0.5 647 2.9 Ducts
Ducts 2982 13.3
Ventilation 0 0
Internal gains 3980 17.8 Glazing Infiltration
Blower 0 0
Adjustments 0 Ceilings
Total 1 1 22354 100.0 Other
Latent Cooling Load=3075 Btuh
Overall U-value= 0.105 Btuh/ft2-°F
Data entries checked.
-Fk-=ightac ft- 2018-May-01 10:18:25
.� ^�^•� Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1
,4C(:�k ...uipment%1791 sf ADS template 2.5ton Carrier.rup Calc=MJ8 Front Door faces:SE
Pro ect Summa Job: 791A1 sf ADS
J � 5
Date: 11/2018
Entire House By: Dave
Bayonet Plumbing Heating and Air
Project Information
For: Lennar Homes
Notes:
Design Information
Weather: Tampa International AP, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 31 OF Outside db 91 OF
Inside db 70 OF Inside db 75 OF
Design TD 39 OF Design TD 16 OF
Daily range L
Relative humidity 50 %
Moisture difference 55 gr/lb
Heating Summary Sensible Cooling Equipment Load Sizing
Structure 23331 Btuh Structure 19372 Btuh
Ducts 2616 Btuh Ducts 2982 Btuh
Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh
Humidification 0 Btuh Blower e) 0 Btuh
Piping 0 Btuh
Equipment load 25947 Btuh Use manufacturer's data y
Rate/swing multiplier 1.00
Infiltration Equipment sensible load 22354 Btuh
Method Simplified Latent Cooling Equipment Load Sizing
Construction quality Semi-tight
Fireplaces 0 Structure 2541 Btuh
Ducts 534 Btuh
Central vent(0 cfm) 0 Btuh
Heatingg Coolingg (none)
Area(ft') 1817 1817 Equipment latent load 3075 Btuh
Volume(ft3) 15459 15459
Air changes/hour 0.26 0.14 Equipment Total Load (Sen+Lat) '25429 Btuh
Equiv.AVF(cfm) 67 36; Req. total capacity at 0.85 SHR 2.2 ton
Heating Equipment Summary Cooling Equipment Summary
Make Carrier Make Carrier
Trade Trade
Model 25HBC53OA00300 Cond 25HBC53OA00300
AHRI ref 9154945 Coil FX4DNF031L
AHRI ref 9154945
Efficiency 8.5 HSPF Efficiency 12.5 EER, 15 SEER
Heating input Sensible cooling 24140 Btuh
Heating output 28200 Btuh @ 47OF Latent cooling 4260 Btuh
Temperature rise 26 OF Total cooling 28400 Btuh
Actual air flow 1000 cfm Actual air flow 1000 cfm
Air flow factor 0.039 cfm/Btuh Air flow factor 0.045 cfm/Btuh
Static pressure 0 in H2O Static pressure 0 in H2O
Space thermostat Load sensible heat ratio 0.88
Capacity balance point= 30 OF
Backup: n/a n/a
Input= 0 kW, Output= 0 Btuh, 100 AFUE
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
-flea- wrightsof[® 2018-May-01 10:18:25
Right-Suite®Universal 2018 18.0.16 RSU05714 Page 1
� ...uipment\1791 sf ADS template 2.5ton Carrier.rup Calc=MJ8 Front Door faces:SE
Manual S Compliance Report Job: 1791A1 sf ADS
Date: 511/201 S
Entire House By: Dave
Bayonet Plumbing Heating and Air
Project Information
For: Lennar Homes
Cooling Equipment
Design Conditions
Outdoor design DB: 91.3°F Sensible gain: 22354 Btuh Entering coil DB: 75.7°F
Outdoor design WB: 77.3°F Latent gain: 3075 Btuh Entering coil WB: 62.8°F
Indoor design DB: 75.0°F Total gain: 25429 Btuh
Indoor RK 50% Estimated airflow: 1000 cfm
Manufacturer's Performance Data at Actual Design Conditions
Equipment type: Split ASHP
Manufacturer: Carrier Model: 25HBC530A00300+FX4DNF031L
Actual airflow: 1000 cfm
Sensible capacity: 24140 Btuh 108% of load
Latent capacity: 4260 Btuh 139% of load
Total capacity: 28400 Btuh 112% of load SHR: 85%
Heating Equipment
Design Conditions
Outdoor design DB: 30.8°F Heat loss: 25947 Btuh Entering coil DB: 69.6°F
Indoor design DB: 70.0°F
Manufacturer's Performance;Data at Actual Design Conditions
Equipment type: Split ASHP
Manufacturer: Carrier Model: 25HBC530A00300+FX4DNF031L
Actual airflow: 1000 cfm
Output capacity: 22528 Btuh 87% of load Capacity balance: 30 °F
Supplemental heat required: 3419 Btuh Economic balance: -99 °F
Backup equipment type: Elec strip
Manufacturer: n/a Model: n/a+n/a
Actual airflow: 1000 cfm
Output capacity: 0 kW 0% of load Temp. rise: 0 °F
Meets all requirements of ACCA Manual S.
Wrightsoft® 2018-May-01 10:18:25
Right-Suite6l Universal 2018 18.0.16 RSU05714
Page 1��
...uipment11791 sf ADS template 2.5ton Carrierrup Cale=MJ8 Front Door faces:SE
Jacqueline Boges
From: Nichole Spence (City of Zephyrhills Support)<support@zephyrhillsfl.zendesk.com>
Sent: Saturday, July 14, 2018 11:47 AM
To: Jacqueline Boges
Subject: [FATHOM] Re: 3123 Kresterbrooke lane by#19810
##- Please type your reply above this line -##
Your request (#223421) has been solved. TO REOPEN THIS REQUEST, reply to this email or click the link below:
https://zephyrhilisfl.zendesk.com/hc/requests/223421
....................................................................................................................................................................................................................................................................................................................................................................................
Nichole Spence (City of Zephyrhills Support )
Jul 14, 8:47 AM MST
Hello Jacqueline Boges,
The changes you requested have been completed.
I am marking this ticket as solved.
Best Regards,
Nichole I FATHOM Support
.......................................................................................................................................................................................................................................................................................................................................................................................
Nichole Spence (City of Zephyrhills Support )
Jul 13, 3:1 S PM MST
Account # 2996719 has been created, service order to follow once mapping has been
completed.
Best Regards,
Nichole I FATHOM Support
......................................................................................................................................................................................................................................................................................................................................................................................
t Jacqueline Boges
---- Jun 29, 7:36 AM MST
full service 3123 Kresterbrooke Lane by#1 9810 water,sewer, water meter
This email is a service from City of Zephyrhills Support .
1
Jacqueline Boges
From: Nichole Spence(City of Zephyrhills Support )<support@zephyrhillsfl.zendesk.com>
Sent: Friday, July 13, 2018 6:16 PM
To: Jacqueline Boges
Subject: [FATHOM] Re: 3123 Kresterbrooke lane by#19810
##- Please type your reply above this line -##
Your request (#223421) has been updated. REPLY TO THIS EMAIL or click the link below:
https://zephyrhillsfl.zendesk.com/hc/requests/223421
.......................................................................................................................................................................................................................................................................................................................................................................................
! Nichole Spence (City of Zephyrhills Support )
—- -- Jul 13, 3:1 5 PM MST
Account# 2996719 has been created, service order to follow once mapping has been
completed.
Best Regards,
Nichole I FATHOM Support
.............................................................................................................................................................................................................................................................................................................. ....................................................
if Jacqueline Boges
Jun 29, 7:36 AM MST
full service 3123 Kresterbrooke Lane by#1 9810 water,sewer, water meter
This email is a service from City of Zephyrhills Support .
1
Jacqueline Boges
From: City of Zephyrhills Support<support@zephyrhillsfl.zendesk.com>
Sent: Friday, June 29, 2018 10:37 AM
To: Jacqueline Boges
Subject: [Request received] 3123 Kresterbrooke lane by#19810
##- Please type your reply above this line -##
Hello Jacqueline Boges,
We are working to resolve your request promptly and will keep you updated. One of our Support Analysts will keep
you updated on the progress of your request.
Best Regards,
FATHOM Support Team
TO ADD ADDITIONAL COMMENTS, reply to this email or click the link below:
https://zephyrhilisfl.zendesk.com/hc/requests/223421
.......................................................................................................................................................................................................................................................................................................................................................................................
Jacqueline Boges
- ' Jun 29, 7:36 AM MST
full service 3123 Kresterbrooke Lane by#19810 water,sewer, water meter
This email is a service from City of Zephyrhills Support .
1
Lennar Homes-3123 Kresterbrooke Ln-2,276 sq ft
Column ts
SQ. FEET PRICE
MAIN OR LIVING: 2,276 $ 112.65
OTHER AREA UNDER ROOF: - $ 88.00
OTHER: - $ -
VALUATION $ 256,391.40
FEE SHEET $ 1,325.00
ADDRESS $ 30.00
DRIVEWAY $ 45.00
BUILDING: $ 1,426.50
ELECTRICAL: $ 298.13
PLUMBING: $ 198.75
MECHANICAL: $ 139.13
SUB-TOTAL $ 2,062.50
TOTAL $ 2,062.50
SEWER: $ 2,090.00
WATER: $ 1,010.00
IRRIGATION: $ -
TOTAL: $ 3,100.00
WATER METER: $ 473.78
IRRIGATION METER
FIRE DEPARTMENT FEES
PLANS TOTAL: n/a
INSPECTION TOTAL:
PERMIT TOTAL
TOTAL: $ -
PUBLIC SAFETY IMPACT FEES
POLICE $ 254.00
FIRE $ 273.00
5% $ 26.35
TOTAL: $ 553.35
SUB-TOTAL $ 6,189.63
PARK IMPACT FEES $ 769.56
SIF'S: $ 7,128.00
100.0% $ 7,128.00
1.0% $ 71.28
TOTAL: $ 7,199.28
T I F'S: $ 3,632.00
99% $ 31595.68.
1% $ 36.32
TOTAL: $ 17,790.47
n� >
City of Zephyrhills
BUILDING PLAN REVIEW COMMENTS
Contractor/Homeowner: (No-/r
Date Received: %,Q,t
Site: bll�prf � , be.4aY- 6 '
1
Permit Type:
Approved w/no comments:❑ Approved w/the below comments: Denied w/the below comments: ❑
This comment sheet shall be kept with the permit and/or plans.
Kalvm S i er—Plans Examiner Date Contractor and/or Homeowner
(Required when comments are present)
24-26-21-0100-00000-1170 1 Pasco County Property Appraiser Page 1 of 1
Data Current as Of: Weekly Archive - Monday, June 11, 2018
Parcel ID 24-26-21-0100-00000-1170 (Card: 001 of 001)
Classification .00 - Vacant Residential
Mailing Address Property Value
LENNAR HOMES LLC Ag Land $0
4600 W CYPRESS ST STE 200 Land $28,921
TAMPA FL 33607-4099 Building $0
Physical Address Extra Features $0
3123 KRESTERBROOKE LANE
ZEPHYRHILLS, FL 33540
Just Value $28,921
Legal Description (First 4 Lines) Assessed (Non-School Amendment 1) $28,921
HIDDEN RIVER PHASE ONE B
PB 76 PG 077
LOT 117 Taxable Value $28,921
OR 9737 PG 3770
Jurisdiction
City of Zephyrhills
Land Detail (Card: 001 of 001) _
Line Use Description Zoning Units Type (Price Condition jValue
1 0100 SFR MPUD 6,000.00 SF $4.50 1.00 $27,000
2 0100 SFR 1 MPUD 12,134.00 SF $0.90. 1.00 $1,921
_ Additional Land Information
Acres 0.19 Tax Area) 30ZH Code -- Residential Code HDRVLPI
Building Information - Use 00 - Unimproved (Card: 001 of 001)
Unimproved Parcel 00 - Unimproved
Extra Features (Card: 001 of 001)
Line Description IYear Units _ value
No Extra Features
Sales History- See All 6 sales
Previous Owner: DUNE FL LAND I SUB LLC
Month/Year Book/Page IType DOR Code Condition !Amount
06/2018 9737 / 3770 Warranty Deed 05 Vacant ! Multi-Parcel Sale
09/2011 8606 % 3376 Warranty.Deed 05 Vacant Multi-Parcel Sale
06/2010 8360 / 1872 I Certificate of Title 12 Vacant $0
http://search.pascopa.com/parcel.aspx?parcel=2126240100000001170 6/15/2018
PASCO COUNTY, FLORIDA
_ Permit No. . / 6 10
Date Permitted
Builder Name/Owner Name L Z A^A r' Me'/-'tC /Control#'
County Parcel No. 2�—Z(0-21-61M--MOD-1170 SubDly: lr9vlkl� A191
Address/Location 3t 20 Al b ke-
Classification/Type of Use r\/'t 0
TRANSPORTATION IMPACT FEE . Rate: Sq.Ft Unit: 21 Z 74
Exempt ❑ Yes ❑ No How Determined
Impact Fee Amount $. �j c3 Z. Zone No. TAZ:
SCHOOL IMPACT FEE
Account (056). Single-Family Detached House Amount $ Z
(057) Mobile Home
(058) Other Residential
123) Collection Fee
Exempt [ Yes ❑ No How Determined
PARKS AND RECREATION FEE
Land Account Land Credit Land Total
Recreation Account Recreation Credit Recreation Total
Zone TOTAL AMOUNT $ 56
Exempt R Yes ❑ No How Determined
LIBRARY FEE
Land Account Land Credit Land Total
Facility Account Facility Credit Facility Total
Exempt ❑Yes ❑ No How Determined Total Amodivi
RESOURCE FEE ERU
TOTAL AMOUNT
Prepared By r Checked By
NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION
PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE
BEEN PAID AND
RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY
Acknowledgement below does not imply acceptance of concurrence,but simply receipt of a copy of this form,placing
the building permit owner,on notice of this assessment and the conditions of payment for same.
-------------
DATE RECEIVED,BY
RECEIPT NO. DATE BY
. � � 11�111111�111111111ii11�11111111i111�l1i1{IIIII�III{Ilill�ll_.
11cipt:1066651 kee: 10.00
DS: 0.00 IT: 0.00
�6/19/2018 C. F. , Dpty Clerk
,4ULA S.o,-NEL,*P'h,U_.06S66 CLERK lk C0C113"TROLLER
B6/19/2018 10:47am I of I
OR BK 9743 n 1079
Permit No. Parcel 10 No 24-26-21-0100-00000-1170
NOTICE OF COMMENCEMENT
State of Florida County if Pasco
THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 713,Florida Statutes,
the following information is provided In this Notice.of Commencement: i
1 Description of Property: Legal HIDDEN RIVER PHASE ONE B PB 76 PG177 LOT 117
street Address: 3123 Kresterbrooke Lane Zephryhills FL 33541
2. General Description of Improvement Single Family Residence t Pool Screen Enclosure I Fence
3. Owner Information: Lennar Homes,.LLC.
Name
4600 W Cypress St. Ste 200 Tampa FL. 33607
Address city State
Interest in Property:
Name of Fee Simple Titleholder: ..N/A
(if other than owner)
Address city State
4. Contractor: Lennar Homes, LLC
Name -
4600 W Cypress St, Ste 200
Tampa FL,33607
Address city State
Contractor's Telephone No.. 813.574.5700
6. Surety: N/A
Name.
Address city State
Amount of Bond: $ I Telephone No.:
6. Lender: N/A
Name
Address city State
Lenders Telephone No.:
7. Persons within,the State of Florida designated by the owner upon whom notices or other documents may be served as provided by
Section 713.13(1)(a)(7),Florida Statutes:
Lennar 146mes, LLC
Name
4600 W Cypress St., Ste 200 Tampa FL 1 33607
Address I city. State
Telephone Number of Designated'Person: 813.574.5700
8. In addition to himself,the owner designates N/A of
to receive a copy of the iienor's Notice as provided in Section 713.13(1)(b),Florida.Statutes.
Telephone Number of Person or Entity Designated by Owner:
9. Expiration date of Notice of Commencement Is one year from the date of recording unless a different date Is specified:
i
WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT
ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713', PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE
RECORDED AND POSTED ON THE JOB SITE.BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT.
STATE OF FLORIDA
COUNTY OF PINELLAS
Signature of Owner or Owner's Authorized Officer/Director/Partner/Manager
Vice President
Signatory's Title/Office
The foregoing instrument was acknowledged before me this 30 day of March —,by
Steve Robert Smith as Vice President (type of authority,e.g.,officer,trustee,attorney In fact)for
Lennar Homes, LLC (name of party on b alf of ristrument was executed)'.
Personally Known R OR Produced Identification 0 Notary SlAnaturb",
Type of Identification Produced Name(Print) Elissa HoTfeiran
Verification pursuant to Section 92.525,:Florida Statutes. Under penalties of pegury,I declare that I have read the foregoing and that the facts stated in
it are true to the best of my knowledge and belief.
ELMO HOLLER A,:N :] Signature of Natural Person Signing Above
E01res-Ane-0,2020
wpdata/bcs/bcs form; IWnd0nruTmyF&In[ioumnmjw4*nI9
14L
31
7
- 7AA9
lcu)
- A.M
AA4.' .'19080
---
A
........ .... x ............... V7423 Fr EL
t FFE&
L-L
A 99 120raga
0 ,62 : P
25
A'
A A
,310 \rim/
A A I I 247riz
A ! Azg-"-
WFFr:L I A 1
FFEL
.3 A
r FFEL 4
Lai Fr-FL' 102.
io VMS/
A
I A I
FF& I
------ ------
FF EL im
35 1 A I
72t
1,22ZM��
1A
I L
I A
LAJ
L---------- 4
I Pat
36 MF EL
104 121
A Lb =A
FF—FE7L
37 177- \TAM/
120 r-A-1
106
1p
L4�y
3
39
FrM.
40 106
72.35
A A
r= t tFFEL I
ffA
R W It t. A t
ffAM t 07
>
\rim/
tit
all
8
A 10
X i.
FF EL
:log \v
A I
Fr-a-
V 2�1
I \ ,27
A
'72M F-A-1
NCI
its it
Iftlay-How SCALE AS NOTED
and Assodates, Ine. "E5'Gtlm !3T sp HIDDEN F;
2006 KlML-zY-HQRN AND ASSOCIATES, NC, DRAWN BY
5344 97H TMEET, ZEPHYRKiLLS, AWRIDA 33-042
PHONE (513) 7SE-0400 FAX (Sll) 782-497S
AN'AVKlML4y-H0RN,CVM CA CM00525 CkEECRED ElY CLC
CITY OF Z,.cPHYRHlU
PLOT PLAN SKETCH ONLY NOT A BOUNDARY SURVEY SEC. 24 TWP. 26 S, RNG. 21 E.
LOT 117 BEARING BASIS:
HIDDEN RIVER PHASE ONE B NORTH BOUNDARY OF SUBJECT PLAT BEING S 89'40'43" E
PASCO COUNTY, FLORIDA. T THIS SURVEY IS SUBJECT TO ANY FACTS THAT
1 MAY BE DISCLOSED BY A FULL AND ACCURATE
ON LOT AREA CALCULATIONS TITLE SEARCH. ALSO SUBJECT TO SETBACKS,
LOT =_8133.86_SQ. FT. EASEMENTS AND RESTRICTIONS OF RECORD.
LIVING AREA =__18L$--SQ. FT.
ENTRY =__32 _SQ. FT. M UNDERGROUND FOOTE STEM WALL, AND
GARAGE =__406_SQ. FT. UNDERGROUND UTILITIESS ARE NOT LOCATED OR
COVERED LANAI =__�A SQ. FT. II SHOWN.
PATIO =__23__SQ. FT. DO NOT SCALE THIS PRINT. DIMENSIONS AND,
CONC. DRIVE __ 34a_SQ. FT. ci NOTES TAKE PREFERENCE.
A/C & CONC PAD =__9___SQ. FT.
PRIVATE SIDEWALK = 72__SQ. FT. DESCRIPTION NOT CONTAINING PLAT BOOK AND
IMPERVIOUS =�34 % PAGE IS
LOT 106 PRELIMINARY INDICATES THAT
TAND ISLASUBJECT IN SUBJECT=
SOD 2Z28_SQ. FT. HIDDEN RIVER PHASE ONE A CHANGE AND/OR REVISION.
=__5406 SQ. FT. (PLAT BOOK 74. PAGES 101-121)
OFF LOT AREA CALCULATIONS CERTAIN DATA SHOWN HEREON BASED ON
ENGINEERING PLANS PROVIDED BY CLIENT.
RIGHT OF WAY =_ 1 Q70 81_SO. FT. \
DRIVE APRON = 144 gq. FT, STRUCTURE TIES SHOWN HEREON DENOTES
PUBLIC SIDEWALK =_35_3 SQ. FT. MEASUREMENT FROM FORM BOARDS/FOUNDATION
SOD =_5_74_SQ. FT. TO PROPERTY LINE.
TOTALS PRELIMINARY DRAWING:
AREA = 9204.67 SQ. FT. 2•. THIS PLAN IS FOR PERMITTING PURPOSES
DRIVEWAY =__492 Y_SQ. FT. \ wp.• -(70.90') ONLY, NOT FOR CONSTRUCTION. VERIFY
SIDEWALK =_425 _SQ. FT. \ `�•'. ALL DIMENSIONS BEFORE ANY CONSTRUCTION.
SOD = 5980 _SQ. FT. \\N•'
\f` LEGEND:
LOT 107 G� �p,'•.�9� A _��= PROPOSED DRAINAGE FLOW
HIDDEN RIVER PHASE ONE A :�\ h ° (00.00) = PROPOSED GRADE
9
(PLAT BOOK 74, PAGES 101-121) LOT 118 E-00.00 = EXISTING GRADE
LOT 117 1ri �\\ O * = 10' DRAINAGE/UTILITY EASEMENT
P \\ F ** = 10' DRAINAGE EASEMENT
E \\ 7
/•• •'Hss• •':�� o \\ * ,70
PLAT
2y '•.o. ut s \ BOUNDARY 00,
NO
�Q 59 SSS• \\\
05
OePLAT
BOUNDARY �3�h Q�Q �'PF .`Vv'•.
�'sss• GP�� \y/ (70.50') /
06,• qSo;.. .
O /
LOT 116 ! •'•. � // •'
�O aTa'•, ,; AO s1
i
P
Gp0 /� F.�QQG�yl
PRM(P)�
NOTES:
a a ° LOT GRADING TYPE = A
PROPOSED PAD ELEVATION = N/A
FRONT SETBACK = 20'
SIDE SETBACK = 10'
REAR SETBACK = 10'
DESCRIPTION: PROPOSED:
LOT 117, MAP OR PLAT ENTITLED "HIDDEN RIVER PHASE ONE B", LOWEST FLOOR ELEVATIONS:
AS RECORDED IN PLAT BOOK ___, PAGES ___ THROUGH LIVING AREA: 72.00'
OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. GARAGE AREA: N/A
ELEVATIONS REFERENCED TO
CURVE RADIUS ARC CHORD BEARING DELTA NATIONAL GEODETIC VERTICAL
cal 1 350.00' 1 87.73' 1 87.50' S 47.43'01" W 1a2V41' DATUM OF 1929. MEAN SEA
C48 350.00' 59.37' 59.29' S 59.45'25" W 09.43'06"
C50 240.00' 1 60.16' 1 60.00' 1 N 47.43.01" E 14.21'41" LEVEL= 00.00 FT.
APPARENT FLOOD HAZARD ZONE: "X" COMMUNITY PANEL N0. 120230 0460 D EFFECTIVE DATE: 9/30/1992
LEGEND:
(C)= CALCULATED DATA, (D)= DEED DATA. (M)= MEASURED DATA. (P)= PLAT DATA, q= CENTERLINE, A/C= AIR CONDITIONER, B/C= BACK OF CURB. C/S=
CONCRETE SLAB, CH= CHORD, CHB= CHORD BEARING, CLF= CHAIN LINK FENCE, CONC= CONCRETE, COV.= COVERED, E/P= EDGE OF PAVEMENT, ESM'T= EASEMENT,
F/C= FENCE CORNER, FCM= FOUND CONCRETE MONUMENT, FIP= FOUND IRON PIPE, FIR= FOUND IRON ROD, FN&D= FOUND NAIL & DISK, FPP= FOUND PINCHED
PIPE, LFE= LOWEST FLOOR ELEVATION, MAS.= MASONRY, OR= OFFICIAL RECORD BOOK, PB= PLAT BOOK, PCP= PERMANENT CONTROL POINT, PRM= PERMANENT
REFERENCE MONUMENT, R/W= RIGHT OF WAY, R= RADIUS, SIR=SET 1/2" IRON ROD & CAP No. 4493, SN&D= SET NAIL & DISK, TBM= TEMPORARY BENCHMARK,
U P= UTILITY POLE, W F= WOOD FENCE R = RADIAL
JOHN R.BEACH&ASSOCIATES,INC. Drawn By: SMS Square Feet: 8133.86 t LENNAR HOMES
SURVEYORS AND MAPPERS Checked By:
911 WEST ST. PETERSBURG DRIVE
ONE OLDSMAR, FLORIDA 34677 JRB
WAY (813) 854-1276 FAX (813) 855-8370 Scale: 1"=30'
NOT VALID WITHOUT THE SIGNATURE AND Date of Survey: �� ��
THE ORIGINAL RAISED SEAL OF A FLORIDA PLOT PLAN 04/18/2018 RTM JOHN R. EACH DATE
LICENSED SURVEYOR AND MAPPER FLORI RE . LAND SURVEYOR No. 2984 LB 4493
Revisions:
PASCO COUNTY
PASC DEVELOPMENT SERVICES
8731 Citizens Drive Date:8/712018
.COUN,ry FLORIDA. New Port Richey,FL 34654
SPACUo VIBM 5p
LACES. -i, P.
727 W -847-2411
OT A, PE RM I T
Receipt#: 1782502
FEE DESCRIPTION ACCOUNT CODE UNITS. INVOICE# FEE AMOUNT PAID RECEIPT# DATE
Impact'Fee Residential Solid 245031 00=32901 0 25.56 1372066 $25.50 $25.50 1782502 8/71-18
Waste Single Family
3123 KRESTERBROOKE LANE.
TOTALS: $25.60 $26.60
Receipt A Paid By Check# CC Auth# Cashier ID Workstation Receipt Date Amt Paid
1782502 Check 01029756 554 BCCCP58VY 08/071/2018 u6:50
Total Payments: $25.50
Pavor Address Phone
LENNAR HOMES LLC
Comments:
3123 KRESTERBROOKE LANE
while you will be paying your bill With Pasco County Development Services,the full amount of the credit card or e-cheek fees,NOT shown above,Is collected by
First billing payment services.
02895856 Uhnair Homes,LLC-
JPMorgan Chase Bank,N.A. STUB CHECK NO. 1029756
900060.11616.114 1 of j DATE 08/02/18
INVOICE
CO.0 NUMBER DATE- PAYMENT.4DVICE GROSS DISCOUNT NET
1 1 5174 15174720117-.401435 07248 151*20117.401435- $25.50 $0.66. $25.3,0
12�j I 30/ 0
County 15MC- 7530 Little Road ".$25.50 som $25.50
101591 "asco Port Richey FL.:33553-0000 --
MyReports/reports]/PASCOPRob/PASCO/R6ceiptPO8 V6.rpt 8[712018 page 1 of 1
�1
4`
5
PASCO COUNTY
PLI S ``; \';'`" DEVELOPMENT�SERVICES.
l 1 '8731 Citizens Drive Ode:817/2018
COCJNTY FLORII�t1, New Part:Richey;FL 34654'
---
** NOT A, PERMIT **
Receipt.#.: 1 Z82511
,FEE DESCRIPTION' ACCOUNT.CODE. UNITS INVOICE# FEE AMOUNT. PAID RECEIPT# DATE
impact'Fee.Residential:Solid 245031,40-329010 25.501 137207Q $26.50: $25:50: 178251T 817/18
Waste Singie;Farnily
3141 KRESTERBROOKE LANE:
TOTALS: $25.50 :$25:50
12eceiot# Nid.By Check# CCAiithW' Cashier ID Workstation RecelbtDate AfMYPaid
1182511 Check: _01,029,757 5,54- BCCGP518W 08/0712018' $25.5Q
Total Payments:• $25.66,
P.avor Address Phone
'.LENNAR.HOMES LLC
'Comments-,
8141 KRESTERBROOKE LANE
wmle'.you Will be_liaying your bill a Jith,Pesco`t'ounty Development Serviced,the full amount of the creditcard 6r`e4heck fees,NDTShown pbove,'ls collected by
First 0111C4 payment Services:
02895856: Lennar Homes;,Ll C JP1vlorgan Chase'Bank,'N.A. STUB CHECKNO. 1029757
g00006.1Q10.114 1 of 'I DATE' ,08/02/1.8
INVOICE,
10.3i. NUM& 12 DriTE Ps1YMENT-WME. GRoss D/SCQlINT� NET'
IS 1,74 :15174120,1 18Ao 1435, 07241 8 ' 1.5174720118-A01435 $25.50. . $0:00' 125.50
r 1,
z
l47259T :Pasco ; unty 7530 Little,Road
PorfRichey-FL33553=0Q00 $25:50' $0.00 $25.50
1' ..
MyReports/reportsUP_A8GOPROD/PASCO%ReceiptPo5 V6.rpt 8/7/2018' ;Page 1 of