Loading...
HomeMy WebLinkAbout18-19886 CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 19886 BUILDING PERMIT PERMIT INFORMATION LOCATION INFORMATION . Permit Number: 19886 Address: 7411 APPLEGATE DR Permit Type: ADDITION/ALTERATION ZEPHYRHILLS, FL. Class of Work: 434-ADD/ALT RESIDENTIAL Township: Range: Book: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Square Feet: Subdivision: ALPHA VILLAGE Est. Value: Parcel Number: 35-25-21-005A-00000-1070 Improv. Cost: 8,600.00 rOWNER INFORMATION Date Issued: 6/29/2018 Name: MYERS BRUCE Total Fees: 127.50 Address: 7411 APPLEGATE DR Amount Paid: 127.50 ZEPHYRHILLS, FL. 33540-1034 Date Paid: 6/29/2018 Phone: (813)469-2793 Work Desc: REPLACE.6 WINDOWS/2 DOORS S/S CONTRACTORS APPLICATION FEES - LIPTON WINDOW & DOOR BUILDING FEE 127.50 f' Ir Ins ections.Required FOOTER 2ND ROUGH PLUMB MIS(; INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC misc.- 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC, DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection. NOTICE: In addition to the requirements of this permit, there maybe additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for Improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. TRACTOR SIGNATURE PERMIT OFFI R PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department i Date Received �C Phone Contact for Permitting 81 06-9895_ Owner's Name Bruce Myers Owner Phone Number 813-469-2793 Owners Address 1 7411 Applegate Dr Zephyrhills 33540 Owner Phone Number Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS 7411 Applegate Dr LOT# 107 SUBDIVISION Alpha Village Estates PARCELID#F 35-25-21-005A-00000-1070 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED e NEW CONSTR e ADD/ALT = SIGN = = DEMOLISH INSTALL REPAIR PROPOSED USE = SFR 0 COMM = OTHER TYPE OF CONSTRUCTION = BLOCK Q FRAME = STEEL = DESCRIPTION OF WORK Replace size for size 6 Windows,2 Doors BUILDING SIZE I =1 SQ FOOTAGE= HEIGHT =BUILDING $ 8600 VALUATION OF TOTAL CONSTRUCTION =ELECTRICAL $ AMP SERVICE PROGRESS ENERGY = W.R.E.C. =PLUMBING $ 00 =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION V =GAS = ROOFING 0 SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO Tau . BUILDER �"COMPANY Lipton Window and. .Door SIGNATURE REGISTERED I Y/ N FEE CURREN I Y/N Add s 17335 Gunlock Rd Lutz FL 33558 License# CBC1258461 ELECTRICIAN COMPANY SIGNATURE REGISTERED I Y/ N FEE CURREA Y!N Address I License# PLUMBER COMPANY SIGNATURE REGISTERED I Y/ N I FEE CURREN LZ/N Address I License# MECHANICAL COMPANY SIGNATURE REGISTERED I Y/ N FEE CURREN I Y/N Address I License# OTHER COMPANY SIGNATURE REGISTERED I Y/ N FEE CURREN Y!N Address License# 1111111111111111111111111111111111111111111111111111111111111111111 RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stornwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisionsllarge projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. —PROPERTY SURVEY required for all NEW Construction. Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500) Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work,they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as:to;what licensing requirements may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the"contractor Block"of this application for which they will be responsible. If you, as the owner sign as the contractor,that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands,that such fees, as may be due,will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a"certificate of occupancy"or final power release. If the project does not involve a certificate of occupancy or final power release,the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended): If valuation of work is$2,500.00 or more,I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner",I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner"prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction,zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls,Docks,Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone"V"unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume"will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction,I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties,the owner may be cited for violating the conditions of the building permit issued under the attached permit application,for lots less than one(1) acre which are elevated by fill,an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate,cancel,alter,or set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans,construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced. An extension may be requested, in writing,from the Building Official for a period not to exceed ninety(90)days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OB AIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. FLORIDA JURAT(F.S.117.03) OWNER OR AGENT CONTRACT Subscribed and swom to(or affirmed)before me this Subs`ribed a d rn to(o d)b f rg a me this by 19 l�G Who is/are personally known to me or has/have produced Who isl re personally nown to me or has/have produced as identification. as identification. Notary Public Notary Public Commission No. Co misqi No. Name of Notary typed,printed or stamped Name of Notary ty d1Rfc st =�' �:: Commission#FF 150422 , � :;rf expires December 12,2018 %;�RF 4t°:�•` 6ondad thru iroy feln Insuranoo BU0395.7019 SGO; 2(;012 3�S':: %7g5:F,2 1o6K5 a 3�S �r x • 4 D 7Z)G410 Sbp 36Z3 S 36�t7��S RAS FG. FOP yf s I Io Business ♦ 'Professional1 a 1 k__ - BCIS Home I Log In I User Registration { Hot Topic Submit Surcharge Stats&Facts ; Publications FBC Staff I BCIS Site Map Links Search I Florida r Product Approval USER:Public User L �YgRtai Product Approval Menu>Product or Aoolication Search>Application List>Application Detail Y�I FL# L8957rR3 Application Type {�Edito�iatChange 1.Code Version 2017 Application Status ['A Proved ✓7 VV* pA proved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived ❑ Product Manufacturer Vi Win Tech Address/Phone/Email 2400 Irvin Cobb Drive Paducah,KY 42003 (270)538-4431 swheeler@viwintech.com Authorized Signature Steven Wheeler swheeler@viwintech.com Technical Representative Steve Wheeler A IL WORK SHALL COMPLY WITH PREVAILING Address/Phone/Email P Irvin Cobb 0)' Paducah,KY 4200�3 000ES FLORIDA BUILDING CIODE, (270)538-4431 NATIONAL ELECTRIC CODE, swheeler@viwintA""IMUTHE CITY OF ZEPHYRHILL.S ORDINANCES Quality Assurance Representative Ronnie WIlliams Rev/ ��/Address/Phone/Email 2400 Irvin Cobb Dr DATs Paducah,KY 42003 CITY OF ��Zf—` ZEp (270)538-4437 �j �! ,` rwilliams@viwintech.com LAN Ex MI H R Hi L Category Wil s pY Subcategory Single Hung Compliance Method Certification Mark or Listing Certification Agency National Accreditation&Management Institute Validated By National Accreditation&Management Institute Referenced Standard and Year(of Standard) Standard Year AAMA/WDMA/CSA 101/I.S.2/A440 2005 TAS 201 1994 TAS 202 1994 TAS 203 1994 Equivalence of Product Standards Certified By Product Approval Method Method 1 Option A Date Submitted 01/17/2018 Date Validated 01/18/2018 Date Pending FBC Approval Date Approved 01/22/2018 Summary of Products FL# Model,Number or Name Description 8957.1 SL3.100,hp SH,5375 u,r. .c- 3100:SHORELINE P.VC;SINGL•ErHUNG NON-IMPACT"FUL'LY,� :REINFORCED_53x75 Limits of Use Certification Agency Certificate Approved for use in HVHZ:No FL8957 R11 C CAC NI008095.02-R7.Ddf Approved for use outside HVHZ:Yes FL8957 R11 C CAC NI008095.03-R9.pdf Impact Resistant: No Quality Assurance Contract Expiration Date Design Pressure:+75/-75 05/31/2019 Other:FRAME MATERIAL TO BE RIGID PVC FROM VISION Installation Instructions EXTRUSIONS LTD.AAMA CERTIFIED(VEX-1). FL8957 R11 II 08-00159C .odf Verified By: Luis R. Lomas P.E. FL 62514 Created by Independent Third Party:Yes Evaluation Reports FL8957 R11 AE 511305C.Ddf Created by Independent Third Party:Yes 8957.2 SL 3100 i SH 5275 SHORELINE 3100 IMPACT SINGLE HUNG 52X75 Limits of Use Certification Agency Certificate Approved for use in HVHZ:Yes FL8957 R11 C CAC NI008082.01=R8.Ddf Approved for use outside HVHZ:Yes FL8957 R11 C CAC NI008082.02-R7.pdf Impact Resistant:Yes Quality Assurance Contract Expiration Date Design Pressure: +70/-70 04/30/2019 Other:FRAME MATERIAL TO BE RIGID PVC FROM VISION Installation Instructions EXTRUSIONS LTD.AAMA CERTIFIED(VEX-1).-"NOT TO BE FL8957 R11 II 08-00184G 3100SH IMP-Install.pdf INSTALLED 30'OR HIGHER ABOVE GROUND LEVEL"-GLASS Verified By: Luis Roberto Lomas 62514 INTERLAYER COMPLIES WITH THE REQUIREMENTS OF THE Created by Independent Third Party:Yes FLORIDA BUILDING CODE ACCORDING TO MIAMI-DADE NOA Evaluation Reports FOR KURARAY INTERLAYERS-"Safety Glass on outside pane FL8957 R11 AE 511011G-3100 SH IMP Evaluation,ndf required in HVHZ zones" Created by Independent Third Party:Yes Back Ea.t Contact Us;;2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 Th'e State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mall.If you have any questions,please contact 850.487.1395."Pursuant to Section 455.275 (1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 45S,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: w:g W eOhEck Credit Card Safe REVISIONS REV DESCRIPTION DATE APPROVED A UPDATE TO 2007 FBC 01/06/09 R.L. B REVISED NOTES 03/09/12 R.L. C REVISED INSTALLATION DETAILS 07/20/15 R.L. NOTES: 15. FOR ANCHORING THROUGH FRAME INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO REQUIREMENTS OF THE FLORIDA BUILDING CODE. SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 2. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY 16. FOR ANCHORING THROUGH FRAME INTO MASONRY/CONCRETE USE 3/16" TAPCONS WITH TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2 3. 1X BUCK OVER MASONRY/CONCRETE IS OPTIONAL. 1/2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND 4. WHERE SHIM OR BUCK THICKNESS IS LESS THAN 1-1/2" WINDOW UNITS MUST BE INSTALLATION DETAILS. ANCHORED THROUGH THE FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED 17. FOR ANCHORING THROUGH FRAME INTO METAL STRUCTURE USE #10 SMS OR SELF INSTALLATION INSTRUCTIONS. ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO DRILLING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE MATERIAL. STRUCTURE INTERIOR WALL. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION 5. WHERE WOOD BUCK THICKNESS IS 1-1/2" OR GREATER, BUCK SHALL BE SECURELY ALTAILS. FASTENED TO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE. WINDOW UNITS MAY 18. ALL FASTENERS TO BE CORROSION RESISTANT. BE ANCHORED THROUGH.FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH 19. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: 6. WHERE 1X BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED A. WOOD: MINIMUM SPECIFIC GRAVITY OF G=0.42 COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF B. CONCRETE: MINIMUM COMPRESSIVE STRENGTH OF 2,000 PSI. THE ARCHITECT OR ENGINEER OF RECORD. C. MASONRY: HOLLOW/FILLED BLOCK PER ASTM C90 WITH f'm=2,000PSI MINIMUM. 7. BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS D. METAL STRUCTURE: STEEL 18CA (.048") FY=33KSI/FU=52KSI OR PROVIDED. ALUMINUM 6063—T5 FU=30KSI 1/8" THICK MINIMUM 8. FOR FIN INSTALLATION SHIM AS NEEDED. FOR FRAME INSTALLATION SHIM AS REQUIRED AT EACH ANCHOR LOCATION WITH LOAD BEARING SHIM. SHIM WHERE SPACE OF 1/16" OR GREATER OCCURS. MAXIMUM ALLOWABLE SHIM STACK TO BE 1/4". 9. SHIMS SHALL BE LOCATED, APPLIED AND MADE FROM MATERIALS AND THICKNESS CAPABLE OF SUSTAINING APPLICABLE LOADS. 10. WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. 11. FRAME MATERIAL: EXTRUDED RIGID PVC. 12. UNITS MUST BE GLAZED PER ASTM E1300-04. 13. APPROVED IMPACT PROTECTIVE SYSTEM IS REQUIRED FOR THIS PRODUCT IN WIND BORNE DEBRIS REGIONS. 14. FOR ANCHORING THROUGH FIN INTO WOOD FRAMING OR 2X BUCK USE #8 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. SIGNED:0712112015 VINYL W400�RVINEcOBBoDROIVEES, INC `\`\J\ ►R�I'LO�� PADUCAH, KY 42002 `v•��CENBF.� TABLE OF CONTENTS SHORELINE SINGLE HUNG NON — IMPACT _*• 0,.61?61 *= SHEET NO. DESCRIPTION FULLY REINFORCED 53" X 75"NOTES `�0• TAT OF tV .TL 2 ELETES DRAWN:VATIONS R.L. Dwc ND. 08-00159 REV C �`rS/`0RIO 3 — 9 INSTALLATION DETAILS SCALE NTS — 7/25/07 S" 1 OF 9 iii���NAi1 ���\ REVISIONS REV DESCRIPTION DATE APPROVED 53" MAX FRAME WIDTH 53" MAX FRAME WIDTH A UPDATE TO 2007 FBC 01/06/09 R.L. — 16" B REVISED NOTES 03/09/12 R.L. 6" MAX MAX O.C. 6" MAX 16" 6" MAX MAX O.C. � 6" MAX C REVISED INSTALLATION DETAILS 07/20/15 R.L. 6" MAX 6" MAX O // O 12" J MAX O.C. 14" T / MAX O.C. MAX MAX H FRAME FRAME I/�\ HEIGHT HEIGHT // O ❑ 4252 FRAME(OPTIONAL) X FIN INSTALLATION 6" MAX 6" MAX I \� SHORELINE SINGLE HUNG WINDOW SHORELINE SINGLE HUNG WINDOW EXTERIOR VIEW EXTERIOR VIEW 4252 FRAME(OPTIONAL) FRAME FLUSH INSTALLATION FIN INSTALLATION FLUSH INSTALLATION DESIGN PRESSURE RATING IMPACT RATING +75.OPSF NONE O ❑ 4252 FRAME(OPTIONAL) FLANGE INSTALLATION SIGNED:0712112015 ffIll NOTES: VINYL SASH SIZE: 49 1/4" X 37" VINYL WINDOW IRVINTECHNOLOGIES, INC `\\\``SCR�I.LL) �//1. i/ 2. MAXIMUM D.L.O.: 46 3/4" X 33 3/4" PADUCAH, KY 42002 ` •��GENS SHORELINE SINGLE HUNG NON — IMPACT fit-•�7,ffY1�0 96Y• �t= FULLY REINFORCED 53" X 75" =,9_ i/• /r •' ELEVATIONS r-P-. TAT OF •�� DRAWN: OWC N0. REV %��`oS [ORMte R•L.ALE DATE 08 OOT159 C NTS 7/25/07 2 OF 9 REVISIONS 1/2" MIN. REV DESCRIPTION DATE APPROVED EDGE DISTANCE "3 4 MIN / -}� A UPDATE TO 2007 FBC 01/06/09 R.L. WOOD FRAMING EDGE DISTANCE I I B REVISED NOTES 03/09/12 R.L. OR 2X BUCK I I BY OTHERS 1 1/4" MIN. 1/4" MAX. C REVISED INSTALLATION DETAILS 07/20/15 R.L. EMBEDMENT METAL SHIM SPACE 1 STRUCTURE _ BY OTHERS BACKER ROD 1/4" MAX. APPROVED & APPROVED 7 SHIM SPACE SEALANT a SEALANT 0 0° 0 a° #10 WOOD SCREW S L SR OR SELF DRI LLING SCREW EXTERIOR EXTERIOR INTERIOR INTERIOR O 00 0 OO O O NOTES: 0 0 0 0 1. INTERIOR AND EXTERIOR NOT SHOWN FOR LARITY.INISHES,BY OTHERS, 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 la le I I I I SILL TO BE SET I O IN A BED OF Q SILL TO BE SET Q O APPROVED SEALANT 0 ❑O IN ABED OF El APPROVED SEALANT BACKER ROD BACKER ROD & APPROVED 1/4" MAX. & APPROVED SEALANT SHIM SPACE SEALANT 1/4" MAX. O SHIM SPACE WOOD FRAMING METAL OR 2X BUCK STRUCTURE r BY OTHERS I BY OTHERS SIGNED:0712112015 VINYL WINDOW TECHNOLOGIES, INC �%� IR I�LIp�77i, VERTICAL CROSS SECTION VERTICAL CROSS SECTION 2400 IRVINPADUCAH COBB DRIVE v ENS'��.'9�i�.r� WOOD FRAMING OR 2X BUCK INSTALLATION METAL STRUCTURE INSTALLATION = V F HEAD AND SILL SHOWN,JAMBS SIMILAR HEAD AND SILL SHOWN,JAMBS SIMILAR SHORELINE SINGLE HUNG NON - IMPACT *• 0s.61261 *� FULLY REINFORCED 53" X 75" ST =q INSTALLATION DETAILS 0•• AT OF•ktu� DRAWN: DWG N0. REV �iORIOP R.L.LE DATE 08 s00159 c i� NA ll 1\�N NTS 7/25/07 3 OF 9 I+- 2 1/2" MIN. -.I REVISIONS EDGE DISTANCE I REV DESCRIPTION DATE APPROVED CONCRETE/MASONRY - I A UPDATE TO 2007 FBC 01/06/09 R.L. BY OTHERS a ° a B REVISED NOTES 03/09/12 R.L. ' a 1 1/4" MIN. C REVISED INSTALLATION DETAILS 07/20/15 R.L. OPTIONAL 1X BUCK ° ° G EMBEDMENT SEE NOTES 3 - 7 SHEET 1 r BACKER ROD & APPROVED 1/4" MAX. SEALANT SHIM SPACE O3/16" TAPCON EXTERIOR � 0 INTERIOR I I I I BACKER ROD O & APPROVED O SILL TO BE SET NOTES: SEALANT IN A BED OF 1. INTERIOR AND EXTERIOR FINISHES,BY OTHERS, ❑ ❑O APPROVED SEALANT NOT SHOWN FOR CLARITY. OPTIONAL 1X BUCK 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE SEE NOTE 3 - 7 DESIGNED IN ACCORDANCE WITH ASTM E2112 SHEET 1 U 1/4" MAX. SHIM SPACE CONCRETE/MASONRY BY OTHERS —� SIGNED:07/21/2015 • < , a ° VINYL WCTECHNOLOGIES, INC a \�.5 Lp PADUCAH, KY 42002 V•��CENs�9s�y e ° SHORELINE SINGLE HUNG NON - IMPACT *• 0 *= •° ° FULLY REINFORCED 53" X 75" ( k — INSTALLATION DETAILS TATE OF VERTICAL CROSS SECTION DRAWN: DWG N0. REV • [pR10P• CONCRETE/MASONRYINSTALLATION R.L. 08-00159 C ��/sis/ CMG\�� HEAD AND SILL SHOWN,JAMBS SIMILAR SCALE NTS DATE 7/25/07 sNEET4 OF 9 /�i%Nffij �� 1/2" MIN. REVISIONS EDGE DISTANCE 3/4" MIN REV DESCRIPTION DATE APPROVED WOOD FRAMING —� EDGE DISTANCE 1 - A UPDATE TO 2007 FBC 01/06/09 R.L. OR 2X BUCK I B REVISED NOTES 03/09/12 R.L. BY OTHERS 1 1/4" MIN. 1/4" MAX. EMBEDMENT METAL SHIM SPACE C REVISED INSTALLATION DETAILS 07/20/15 R.L. 1 STRUCTURE BY OTHERS BACKER ROD 1/4" MAX. APPROVED a & APPROVED SHIM SPACE SEALANT SEALANT 10 WOOD SCREW S OR # SELF DRILLING SCREW 0 p0� Q EXTERIOR EXTERIOR INTERIOR �� O 0 INTERIOR I I I I SILL TO BE SET Q IN A BED OF O SILL TO BE SET O ❑ ❑O APPROVED SEALANT O ❑O IN A BED OF El APPROVED SEALANT BACKER ROD BACKER ROD & APPROVED 1/4" MAX. & APPROVED SEALANT SHIM SPACE SEALANT 1/4" MAX. METAL SHIM SPACE WOOD FRAMING -T STRUCTURE OR 2X BUCK BY OTHERS BY OTHERS SIGNED:07/21/2015 VERTICAL CROSS SECTION VINYL WINDOW TECHNOLOGIES INC %%111111/1� WOODEFRAICAL MINGORR2OSS BUCKINSTALLATION HEAD AND SILLSHOWNMETAL STRUCTURE NSTALLATION AMBSSIMILAR 2PADUCAH, KYB42002E S�GENS'�9�+ HEAD AND SILL SHOWN,JAMBS SIMILAR SHORELINE SINGLE HUNG NON - IMPACT *' 0(jE„�261�••• � NOTES: FULLY REINFORCED 53" X 75" - 1. INTERIOR AND EXTERIOR FINISHES,BY OTHERS, �'O• NOT SHOWN FOR CLARITY. INSTALLATION DETAILS ��OO TAT OF 2 PERIMETER AND OJOINT SEA ANH ST OTHERS ZOBE DRAWN: DWG NO. R DESIGNEDEV mi �c<`S=c��RI�P SCALE E DATE 08 s00159 c �i�i/oNA� NTS 7/25/07 5 OF 9 2 1/2" MIN. REVISIONS EDGE DISTANCE 1 REV DESCRIPTION DATE APPROVED CONCRETE/MASONRY A UPDATE TO 2007 FBC 01/06/09 R.L. BY OTHERS °d ° e a n B REVISED NOTES 03/09/12 R.L. n ° 1 1/4" MIN. C REVISED INSTALLATION DETAILS 07/20/15 R.L. OPTIONAL 1 X BUCK a ° ° ° ° °e.° EMBEDMENT SEE NOTES 3 — 7 SHEET 1 f l BACKER ROD & APPROVED �� 1/4" MAX. SEALANT SHIM SPACE O3/16" TAPCON EXTERIOR �t INTERIOR I I I Q SILL TO BE SET IN A BED OF NOTES: BACKER ROD APPROVED SEALANT 1. INTERIOR AND EXTERIOR FINISHES,BY OTHERS, & APPROVED ❑ t' O NOT SHOWN FOR CLARITY. SEALANT 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE 1/4" MAX. DESIGNED IN ACCORDANCE WITH ASTM E2112 OPTIONAL 1 X BUCK SHIM SPACE SEE NOTE 3 — 7 SHEET 1 -� SIGNED:0712112015 CONCRETE/MASONRY VINYL WINDOW TECHNOLOGIES, INC ����►lirrrr BY OTHERS 2400 IRVIN COBB DRIVE �� R• '10ii,� PADUCAH, KY 42002 `�v•��GENS 9S�`� ° e SHORELINE SINGLE HUNG NON — IMPACT *• 0y�61 •*= °° • FULLY REINFORCED 53" X 75" INSTALLATION DETAILS + k T VERTICAL CROSS SECTION A0. STATE OF CONCRETE/MASONRYINSTALLATION DRAWN: Owc No. REV %'PFS;:'40RIDV" HEAD AND SILL SHOWN,JAMBS SIMILAR R.E DATE L. O8 5001 59 C NTS 7/25/07 6 OF 9 1/2" MIN. REVISIONS " MIN RE DESCRIPTION DATE APPROVED EDGE DISTANCE 3/4 WOOD FRAMING EDGE DISTANCE A UPDATE TO 2007 FBC 01/06/09 R.L. OR 2X BUCK B REVISED NOTES 03/09/12 R.L. BY OTHERS f_.71MENT MIN. 1/4" MAX. METAL SHIM SPACE C REVISED INSTALLATION DETAILS 07/20/15 R.L. I STRUCTURE BY OTHERS 1/4" MAX. APPROVED BACKER ROD SHIM SPACE SEALANT & APPROVED SEALANT 00 ❑ 10 WOOD SCREW S OR N SELF DRILLING SCREW EXTERIOR EXTERIOR O O INTERIOR Q O INTERIOR I I I I SILL TO BE SET I SILL TO BE SET O IN A BED OF O IN A BED OF ❑ ❑O APPROVED SEALANT O ❑ ❑O APPROVED SEALANT BACKER ROD BACKER ROD & APPROVED 1/4" MAX. & APPROVED SEALANT SHIM SPACE SEALANT 1/4" MAX. r SHIM SPACE WOOD FRAMING METAL ffiffi OR 2X BUCK STRUCTURE BY OTHERS BY OTHERS SIGNED:07/21/2015 VERTICAL CROSS SECTION VERTICAL CROSS SECTION METAL STRUCTURE INSTALLATION VINYL WINDOW TECHNOLOGIES, INC `\�S�R I�LId7j�z WOOD FRAMING OR 2X BUCK INSTALLATION HEAD AND SILL SHOWN,JAMBS SIMILAR 2400 I RV I N COBB DRIVE \�J\ .•••.4l9 HEAD AND SILL SHOWN,JAMBS SIMILAR PADUCAH, KY 42002 ;�,,• \CEAfq SHORELINE SINGLE HUNG NON - IMPACT *• , 0X04F"M, � NOTES: ��''((''��( 1. INTERIOR AND EXTERIOR FINISHES,BY OTHERS, FULLY REINFORCED ETA X 75"NOT SHOWN FOR CLARITYINSTALLATION DETAILS � TV\ 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DRAWN: DWG NO. REV �i°FS aC ORI�Q:G�$`� DESIGNED IN ACCORDANCEWITHASTME2112 R.L. DATE 08 500159 C *77S/ONAI,f�!\��\� NITS 7/25/07 7 OF 9 2 1/2" MIN. .{ REVISIONS EDGE DISTANCE I REV DESCRIPTION DATE APPROVED CONCRETE/MASONRY I A UPDATE TO 2007 FBC 01/06/09 R.L. BY OTHERS '° a B REVISED NOTES 03/09/12 R.L. 1 1/4" MIN. C REVISED INSTALLATION DETAILS 07/20/15 R.L. OPTIONAL 1X BUCK ° ° ° ° EMBEDMENT SEE NOTES 3 — 7 SHEET 1 U BACKER ROD a & APPROVED /4" MAX. SEALANT SHIM SPACE Oa 3/16" TAPCON EXTERIOR t INTERIOR loto I I SILL TO BE SET O IN A BED OF O APPROVED SEALANT NOTES: BACKER ROD ❑ 1. INTERIOR AND EXTERIOR FINISHES,BY OTHERS, & APPROVED ❑ NOT SHOWN FOR CLARITY. SEALANT 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE 1/4" MAX. DESIGNED IN ACCORDANCE WITH ASTM E2112 OPTIONAL IX BUCK SHIM SPACE SEE NOTE 3 - 7 D SHEET 1 SIGNED:0712112015 CONCRETE/MASONRY VINYL WINDOW TECHNOLOGIES, INC ��ul1i11117 BY OTHERS a ° ° e a 2400 IRVIN COBB DRIVE ��\\\\5 R LOd!/�/// PADUCAH, KY 42002 •�\GENs�9'p..,� ° ° 8 ° SHORELINE SINGLE HUNG NON - IMPACT _►fit• p (� ir= a <° FULLY REINFORCED 53" X 75" — f INSTALLATION DETAILS STATE OF VERTICAL CROSS SECTION oanwN: DwD No. REV i0'n••'c�0 CONCRETE/MASONRY INSTALLATION i/FS•••RMt HEAD AND SILL SHOWN,JAMBS SIMILAR SCALE ontE 08 s00159 C /1jis1QNA„�N\\\` NTS 7/25/07 8 OF 9 APPROVED REVISIONS SEALANT REV DESCRIPTION DATE APPROVED BEHIND FIN 1 1/4" MIN. A UPDATE TO 2007 FBC 01/O6/09 R.L. #8 WOOD EMBEDMENT 9 REVISED NOTES 03/09/12 R.L. SCREW WOOD FRAMING C REVISED INSTALLATION DETAILS 07/20/15 R.L. ::!� BY OTHERS 7/16" MIN 1/4" MAX. EDGE DISTANCE SHIM SPACE � a Q 00 EXTERIOR I INTERIOR I O a1/4" MAX SHIM SPACE 7/16" MIN EDGE DISTANCE NOTES: #8 WOOD WOOD 1. INTERIOR AND EXTERIOR FINISHES,BY OTHERS, NOT SHOWN FOR CLARITY. SCREW FRAMING 1 1/4" MIN. BY OTHERS 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE APPROVED EMBEDMENT DESIGNED IN ACCORDANCE WITH ASTM E2112 SEALANT BEHIND FIN VERTICAL CROSS SECTION WOOD FRAMING OR 2X BUCK INSTALLATION SIGNED:07/21/2015 HEAD AND SILL SHOWN,JAMBS SIMILAR VINYL Waoo�RVINEcoeeOD�vEES, INC \```J\g Ri'L0(/�% PADUCAH, KY 42002 `�,•v�GENSF•s SHORELINE SINGLE HUNG NON - IMPACT _*• o 51 *_ FULLY REINFORCED 53" X 75" INSTALLATION DETAILS �0• $TAT OF w� DRAWN: DWG N0. REV ��s'cCOR1�Q: SCALE DATE 08 SOOT S9 C %/�S/QNA 1�1�?\�\� NTS 7/25/07 9 OF 9 ♦ ♦ / / . Regulation ra BCIS Home I Log In User Registration I Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff BCIS Site Map Links Search Florida t,M `' Product Approval USER:Public User p r L. t Product Approval Menu>Product or Application Search>Application List>Application Detail WIN milli FL# �Fl- 012—-it f Application Type (New ,el Code Version 2017 Application Status Approved *Approved by DBPR.Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived ❑ Product Manufacturer MI Windows and Doors Address/Phone/Email 650 West Market Street Gratz,PA 17030 (717)365-3300 Ext 2560 bsitlinger@miwd.com Authorized Signature Brent Sitlinger bsitlinger@miwd.com Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Exterior Doors Subcategory SlidingExtei��ioi'Door,,Assembiies---- Compliance Method Certification Mark or Listing Certification Agency American Architectural Manufacturers Association Validated By Steven M.Urich,PE El Validation Checklist-Hardcopy Received Referenced Standard and Year(of Standard) Standard Year AAMA 506 2011 AAMA/WDMA/CSA 101/I.S.2/A440 2011 AAMA/WDMA/CSA 101/I.S.2/A440 2008 Equivalence of Product Standards Certified By Product Approval Method Method 1 Option A Date Submitted 02/05/2018 Date Validated 02/06/2018 Date Pending FBC Approval Date Approved 02/10/2018 Summary of Products FL# Model,Number or Name Description 26012.1 1615/1617 SGD 144x96 w/Insulated Laminated Glass Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL26012 RO C CAC APC(16613)H0079.01-109-47- Approved for use outside HVHZ:Yes R1 1615-1617 SGD(041722).odf Impact Resistant: No Quality Assurance Contract Expiration Date Design Pressure:+50/-50 04/17/2022 Other:LC-PG50 Installation Instructions FL26012 RO II 08-03131A.odf Verified By: Luis R. Lomas,PE PE-62514 Created by Independent Third Party:Yes Evaluation Reports FL26012 RO AE 514040A 3131.odf Created by Independent Third Party:Yes 26012.2 1615/1617 SGD 106x96 Insulated Glass Limits of Use Certification Agency Certificate Approved for use in HVHZ:No FL26012 RO C CAC APC(16245)AI-04220-A1 1615-1617 Approved for use outside HVHZ:Yes SGD(050519)_pdf Impact Resistant:No Quality Assurance Contract Expiration Date Design Pressure:+40/-40 05/05/2019 Other:R-PG40 Installation Instructions FL26012 RO II 08-03132A.odf Verified By: Luis R. Lomas,PE PE-62514 Created by Independent Third Party:Yes Evaluation Reports FL26012 RO AE 514041A 3132.odf Created by Independent Third Party:Yes (j 26012.3 _ 0 1615/ 61Z SGD_' 71x82-Insulated Laminated-Glass ` L-imits of Use Certification Agency Certificate Approved for use in HVHZ:No FL26012 RO C CAC APC(16465)AI-03810-V1-R3 1615- Approved for use outside HVHZ:Yes 1617 SGD(091520).pdf Impact Resistant:No Quality Assurance Contract Expiration Date Design Pressure:+60/-60 09/15/2020 Other: R-PG60 Installation Instructions FL26012 RO II 08-03129A.odf Verified By: Luis R. Lomas,PE PE-62514 Created by Independent Third Party:Yes Evaluation Reports FL26012 RO AE 514038A 3129.odf Created by Independent Third Party:Yes 26012.4 1615/1617 SGD 187x80 Insulated Glass Limits of Use Certification Agency Certificate Approved for use in HVHZ:No FL26012 RO C CAC APC(16607)G7944.01-109-47- Approved for use outside HVHZ:Yes RO 1615-1617 SGD(030922).odf Impact Resistant:No Quality Assurance Contract Expiration Date Design Pressure:+20/-20 03/09/2022 Other: R-PG20 Installation Instructions FL26012 RO II 08-03133A.odf Verified By: Luis R. Lomas,PE PE-62514 Created by Independent Third Party:Yes j Evaluation Reports FL26012 RO AE 514042A 3133.odf Created by Independent Third Party:Yes 26012.5 1615/1617 SGD 144x96 Insulated Laminated Glass,Impact Limits of Use Certification Agency Certificate Approved for use in HVHZ:No FL26012 RO C CAC APC(16612)H0079.02-109-47- Approved for use outside HVHZ:Yes R1 1615-1617 SGD(041322).odf Impact Resistant:Yes Quality Assurance Contract Expiration Date Design Pressure:+50/-50 04/13/2022 Other:LC-PG50,Missile Level D,Wind Zone 3 Installation Instructions FL26012 RO II 08-03127A.odf Verified By: Luis R. Lomas,PE PE-62514 Created by Independent Third Party:Yes Evaluation Reports FL26012 RO AE 514036A 3127.odf Created by Independent Third Party:Yes 26012.6 1615/1617 SGD 96x96 Insulated Glass REVISIONS REV DESCRIPTION GATE APPROVED A ADDED SILL INSTALLATIONS 01/11/18 R.L. NOTES: 15. FOR ANCHORING THROUGH FRAME INTO MASONRY/CONCRETE USE 1/4" ELCO ULTRACON 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH TAPCONS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO REQUIREMENTS OF THE FLORIDA BUILDING CODE. SUBSTRATE WITH 1" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS 2. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY AND INSTALLATION DETAILS. TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 16. FOR ANCHORING THROUGH FRAME INTO METAL STRUCTURE USE #12 SMS OR SELF 3. 1X BUCK OVER MASONRY/CONCRETE IS OPTIONAL. DRILLING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS.MINIMUM BEYOND 4. WHERE SHIM OR BUCK THICKNESS IS LESS THAN 1-1/2" WINDOW UNITS MUST BE STRUCTURE INTERIOR WALL. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. ANCHORED THROUGH THE FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED 17. FOR ANCHORING THROUGH CLIP INTO WOOD FRAMING OR 2X BUCK USE #8 WOOD SCREWS INSTALLATION INSTRUCTIONS. ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE. MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE MATERIAL. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 5. WHERE WOOD BUCK THICKNESS IS 1-1/2" OR GREATER, BUCK SHALL BE SECURELY 18. FOR ANCHORING THROUGH CLIP INTO MASONRY/CONCRETE USE 1/4" ELCO ULTRACON FASTENED TO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE. WINDOW UNITS MAY BE ANCHORED THROUGH FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH TAPCONS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS. SUBSTRATE WITH 1" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS 6. WHERE 1X BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED AND INSTALLATION DETAILS. COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF 19. FOR ANCHORING THROUGH CLIP INTO METAL STRUCTURE USE #8 SMS OR SELF DRILLING THE ARCHITECT OR ENGINEER OF RECORD. SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE 7. BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS INTERIOR WALL. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. PROVIDED. 20.ALL FASTENERS TO BE CORROSION RESISTANT. 8. FOR FIN INSTALLATION SHIM AS NEEDED. FOR FRAME INSTALLATION SHIM AS REQUIRED AT 21.INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR EACH ANCHOR LOCATION WITH LOAD BEARING SHIM. SHIM WHERE SPACE OF 1/16'. OR MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN GREATER OCCURS. MAXIMUM ALLOWABLE SHIM STACK TO BE 1/4". SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: 9. SHIMS SHALL BE LOCATED, APPLIED AND MADE FROM MATERIALS AND THICKNESS CAPABLE A. WOOD: MINIMUM SPECIFIC GRAVITY OF G=0.42 OF SUSTAINING APPLICABLE LOADS. B. CONCRETE: MINIMUM COMPRESSIVE STRENGTH OF 2,000 PSI. 10. WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. C. MASONRY: HOLLOW/FILLED BLOCK PER ASTM C90 WITH Fm=2,000PSI MINIMUM. 11. FRAME MATERIAL: EXTRUDED RIGID PVC. D. METAL STRUCTURE: STEEL 18GA (.048") FY=331<SI/FU=52KSI OR - ALUMINUM 6063—T5 FU=30KSI .060" THICK MINIMUM 12. UNITS MUST BE GLAZED PER ASTM E1300-04/09, WITH SAFETY GLAZING. 22. APPROVED CONFIGURATIONS: XO, OX. 13. APPROVED IMPACT PROTECTIVE SYSTEM IS REQUIRED FOR THIS PRODUCT IN WIND BORNE DEBRIS REGIONS. 14. FOR ANCHORING THROUGH FRAME INTO WOOD FRAMING OR 2X BUCK USE #12 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 3/8" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. SIGNED:0 1/1 112 0 1 8 MI W I�NDOWSWESTMKET&R DOORREETLC. ````JS RIIiLJO GRATZ, PA 17030 `v,•��CENS�9d+�i SERIES 1615/1 617 PVC SLIDING GLASS DOOR *• Oy6/261 NON - IMPACT XO •• NOTES •, STATE OF TABLE OF CONTENTS �`• P �+� DRAWN: DWG N0. REV ,���s• OR •�\�� SHEET NO. DESCRIPTION .R. DATE 08 031129 A ,S+JONAj1 ? 1 NOTES NTS 06/28/17 1 OF 6 2 ELEVATION AND GLASS DETAIL L.ROBERTOLOMASP.E' Luis R. Lomas P.E. 1432 WOODFORD RD LEWISVILLE,N027023 FL No.: 62514 3 — 6 INSTALLATION DETAILS 434-6B6-0609 rllomas@lrlomaspe.com REVISIONS REV DESCRIPTION DATE APPROVED A ADDED SILL INSTALLATIONS 01/11/18 R.L. * Q NOTES: 1. MAXIMUM PANEL SIZE.,35 518"x 77 9116" 2. MAXIMUM D.L.O.:29 3116"x 71 7116" CHART#1 70 7/8" MAX FRAME WIDTH Number of anchor locations required Frame Frame Width(in) 4" MAX 1 2" MAX O.C. 4" MAX Height 36.00 48.00 60.00 70.88 (in) H 8 S Jamb IH&SlJamb IH&SlJamb H 8 S Jamb r I fr � 81.88 4 8 5 8 7 8 8 8 4" MAX (1) ANCHOR PER LOCATION SEE CHART #1 1� FOR NUMBER 3 3/16" MAX O.C. OF ANCHOR LOCATIONS 1 1/8" REQUIRED 81MAX8 X 0 J —F FRAME /2" ® O O 1 1/16" HEIGHT I 4" MAX 1/4 -- 2 13/16" --- ANCHORS AT SILL CLIP SERIES 161511617 PVC SLIDING GLASS_DOOR NON-IMPACT TO BE INSTALLED EXTERIOR VIEW THROUGH ANCHOR CLIP GALVANIZED STEEL(.051"THICK) UP TO 2 PANEL CONFIGURATIONS ARE QUALIFIED AS LONG AS PANEL AREA DOES NOT EXCEED 19.3 FT?SEE NOTE 22 DESIGN PRESSURE RATING IMPACT RATING ±60.0PSF NONE SIGNED:01/1112018 MI 6 I0 WEST MAR ET STREET LC. \`Nx\\5(R I ILf0�7//�i GRATZ, PA 17030 v•��CENS�9��i� SERIES 1615/1617 PVC SLIDING GLASS DOOR 11t% p 51 �t= NON — IMPACT XO ` 5 � HARDWARE SCHEDULE ELEVATION AND GLASS DETAIL A. (1)HANDLE(9748) ���•/TAT OF; EV B. (1)1 POINT MORTISE LOCK WITH KEEPER(9149) A.R. R DWG No. 08-03129 A C. (1)2 POINT MORTISE LOCK WITH KEEPERS(9249) scALE DATE SHEET D. (2)ROLLERS(9732) NTS 0L ROBER 7 2 OF 6 E. STEEL REINFORCEMENT 9599 AT MEETING STILES LROBERDLEWIS ILLE, Luis R. Lomas P.E. ( ) f432 WOODFORD RD LEWISVILLE,NC 27023 F. STEEL REINFORCEMENT(9598)AT LOCKING STILES 434-686-0609 rllamasalrlomawe.com FL No.: 62514 REVISIONS 1/2" MIN REV OESCRIPTION DATE APPROVED EDGE DISTANCE WOOD FRAMING A ADDED SILL INSTALLATIONS 01/11/18 R.L. OR 2X BUCK BY OTHERS 1 3/8" MIN EMBEDMENT 1 3/8" MIN 1/4" MIN BACKER ROD EMBEDMENT SHIM SPACE & APPROVED SEALANT 1/4" MIN D. SHIM SPACE ❑ 0 ❑ p'❑ INTERIOR O 1/2 �p MIN a� Q ❑ D DISTDANCE O #12 WOOD SCREW �J 1�7 11 ll oO f , � #12 WOOD SCREW D WOOD FRAMING OR 2X BUCK EXTERIOR EXTERIOR INTERIOR BY OTHERS El ❑o BACKER ROD & APPROVED SEALANT JAMB INSTALLATION DETAIL WOOD FRAMING OR 2X BUCK INSTALLATION 0 ® O ANCHOR CLIP BACKER ROD & APPROVED �� 'IU� I #8 WOOD SCREW SEALANT Dp� NOTES: 1. INTERIOR AND EXTERIOR FINISHES,BY OTHERS, 0 ❑ NOT SHOWN FOR CLARITY. WOOD FRAMING b O 1/4 BY OTHERS " MAX 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE OR 2X 0 � a SHIM SPACE DESIGNED IN ACCORDANCE WITH ASTM E2112���� �� _ � SIGNED:01/11/2018 1 1/1 MIN MI WINDOWS & DOORS, LLC. \��\\S1 illt. f/l// EMBEDMENT 650 WEST RA Z,MPAK17030ET REET \v\OFIV qs SERIES 1615/1617 PVC SLIDING GLASS DOOR *• HAT 1/2" MIN NON - IMPACT XO �EDGE DISTANCE INSTALLATION DETAILS � OF VERTICAL CROSS SECTION DRAWN: DWG NO. REV �0'rFs:C[OR10P WOOD FRAMING OR 2X BUCK INSTALLATION A.R. DATE 08 031 29 A 4i�sllDj NTS 06/28/17 3 OF 6 L.ROBERTO LOMAS P.E. Luis R. Lomas P.E. 1432 WOODFORD RD LEWISVILLE,NC 27023 FL NO.: 62514 434-666-0609 rllomas@trlomaspe.com REVISIONS 1/2" MIN REV DESCRIPTION GATE APPROVED METAL EDGE DISTANCE I` A I ADDED SILL INSTALLATIONS 01/I I/18 R.L. STRUCTURE BY OTHERS BACKER ROD 1/4" MIN & APPROVED 71 + SHIM SPACE SEALANT 1/4" MIN SHIM SPACE 0U ❑ CB 1 „ p INTER MINEDGE IOR 0 n n�nn 70 DISTANCE �u 0 0 l0u 0 #12 SMS OR SELF DRILLIGN oO SCREW E SMS OR SELF D LLINC co, SICREW Q _ o EXTERIOR EXTERIOR INTERIOR O O METAL STRUCTURE BACKER ROD �a BY OTHERS & APPROVED SEALANT JAMB INSTALLATION DETAIL ® ANCHOR CLIP METAL STRUCTURE INSTALLATION 0 #8 SMS OR BACKER ROD �,� ]0 SELF DRILLING & APPROVED SCREW NOTES: SEALANT u 1. INTERIOR AND EXTERIOR FINISHES,BY OTHERS, ��,f��}pI�1� ❑ ❑ NOT SHOWN FOR CLARITY. METAL a SHIM SPACE 1/4" MAX 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE STRUCTURE IL!-.JI DESIGNED IN ACCORDANCE WITH ASTM E2112 SIGNED:01/11/2018 BY OTHERS MI WINDOWS & DOORS, LLC. R 11L D�1 650 WEST MARKET STREET GRATZ, PA 17030 `v ENS�9s� SERIES 1 615/1 617 PVC SLIDING GLASS DOOR *• 0�261 *'^ 1/2" MIN NON - IMPACT XO EDGE DISTANCE INSTALLATION DETAILS �y0• TAT OF VERTICAL CROSS SECTION DRAWN: DWG NO. REV pR�aP ��•OF•:�� •�'��� METAL STRUCTURE INSTALLATION A.R. 08-03129 A /iiss/ONAL��G`�\ SCALE NTS DATE 06/28/17 SHEET OF 6 �///1111110\\ L.ROBERTO LOMAS P.E. Luis R. Lomas P.E. 1432 WOODFORD RD LEWISVILLE,NC 27023 FL NO.: 62514 434-OS-0609 dlomas@lrlomaspe.com I" MIN REVISIONS EDGE DISTANCE REV DESCRIPTION DATE APPROVED CONCRETE/ ° A ADDED SILL INSTALLATIONS 01/11/18 R.L. MASONRY n ° 1 1/4" MIN BY OTHERS a° °a 1 1/4" MIN EMBEDMENT SHIM SPACE � ° EMBEDMENT OPTIONAL 1 X BUCK 1" v SEE NOTES 3-7 1 MIN MIN INTERIOR SHEET 1 �I � SHIMIM SPACE EDGE ° DO ❑ ❑ ❑ ¢❑ DISTANCE �Q BACKER ROD & APPROVED n SEALANT 0 V, iu L EPt�dtlggdgtl It l O' O El TAPCON TA ULTRACON ° TAPCONON 1/4" ELCO ULTRACON TAPCON Q II ° EXTERIOR D o p CONCRETE/ ° O MASONRY v ° E] BY OTHERS 0 EXTERIOR INTERIOR ° BACKER ROD OPTIONAL 1X BUCK & APPROVED n n SEALANT SEE NOTES 3-7 Ul u SHEET 1 JAMB INSTALLATION DETAIL ❑❑ CONCRETE MASONRY INSTALLATION ❑ ® O ANCHOR CLIP BACKER ROD o, O 0 1/4" ELCO ULTRACON NOTES: & APPROVED 111 1. INTERIOR AND EXTERIOR FINISHES,BY OTHERS, SEALANT AA�p D❑ TAPCON NOT SHOWN FOR CLARITY. d+ �7 ❑ ❑n 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE 1/4" MAXL�-,J �� ❑ DESIGNED IN ACCORDANCE WITH ASTM E2112 II�U fII SIGNED:01/11/2018 OPTIONAL 1 X BUCK SHIM SPACE SEE NOTES 3-7 _- MI WINDOWS & DOORS, LLC. ���1111111Ti SHEET 1 R• LO 650 WEST MARKET STREET , GRATZ, PA 17030 •4\CENS+�'9S�y CONCRETE/MASONR ° ° ° ° SERIES 1615/1617 PVC SLIDING GLASS DOOR *• 0 b1 BY OTHERS ° ° ° ° ° ° °a ° n° EM EDMENT NON - IMPACT XO =,� �_ n ° ° ° INSTALLATION DETAILS ^ A+ $TAT OF tV� DRAWN: DWG NO. �REV /� •'PCOR�O G\\ 1° MIN scAA.RE NTS DATE D6/28/17 08 SHEET159 OF 6 A FSSjONAI_'i VERTICAL CROSS SECTION EDGE DISTANCE CONCRETE MASONRY INSTALLATION L.ROBERTOLOMASP.E. Luis R. Lomas P.E. 1432 WOODFORD RD LEWISVILLE,NC 27023 FL No.: 62514 434-668-0609 rllomas@lrlomaspe.Com REVISIONS REV DESCRIPTION DATE APPROVED 0 a EXTERIOR OPTIONAL SILL INSTALLATIONS A ADDED SILL INSTALLATIONS 01/11/18 R.L. � O INTERIOR BACKER ROD O 1 laI O O Al2 WOOD SCREW & APPROVED �O EXTERIOR Oa INTERIOR SEALANT ❑ ❑ �b0 1/4" MAX WOOD FRAMING L�f SHIM SPACE OR 2X BUCK t BY OTHERS Y' � IIIIIIIII��N 1/4" ELCO ULTRACON 1 1/4" MIN a h a II�IOII i' O TAPCON EMBEDMENT BACKER ROD & APPROVED Y, ❑ SEALANT ❑ b ❑ 1/4" MAX 1/2" MIN OPTIONAL IX BUCK a SHIM SPACE EDGE DISTANCE SEE NOTES 3-7 SHEET 1 f VERTICAL CROSS SECTION WOOD FRAMING OR 2X BUCK INSTALLATION CONCRETE/ MASONRY BY OTHERS ° ° 1 1/4" MIN 4o ° EMBEDMENT �n1 d INTERIOR L EXTERIOR � GD — 1" MIN EDGE DISTANCE t t ® O VERTICAL CROSS SECTION CONCRETE MASONRY INSTALLATION #12 SMS OR 0 �I SELF DRILLING �❑ SCREW ❑ ° SIGNED:0 1/1112018 BACKER ROD 1/4" MAX & APPROVED tc�b a MI WINDOWS & DOORS, LLC. \��uu►uI��7 SEALANT SHIM SPACE 650 WEST MARKET STREET GRATZ. PA 17030 v• GENS�"9s/� METAL O STRUCTURE SERIES 1615/1617 PVC SLIDING GLASS DOOR fir• 0 AI BY THEIRS NON — IMPACT XO �,� ( * �� INSTALLATION DETAILS . q0• TAT OF DRAWN: DWG N0. REV i�'c•• 0R1�P' 1/2" MIN L _� NOTES: A.R. 08-03129 EDGE DISTANCE 1. INTERIOR NOTSHOANDDEXTERIORyINISHES,BYOTHERS, SCALE DATE SHEET /77��/� A"`1\\\\ FOR NTS 06/28/17 6 OF 6 VERTICAL CROSS SECTION 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE L.ROBERTO LOMAS P.E. METAL STRUCTURE INSTALLATION DESIGNED IN ACCORDANCE WITH ASTM E2112 1432Wo L, ORDRTOLOM SP.ENC27023 Luis R. Lomas P.E. 434-688-0609 rllomas@lrlomaspe.com FL No.: 62514 - ee 1 �l Business 0 C ® ♦ Regulation - BCIS Home Log In User Registration Hot Topics Submit Surcharge I Stats&Facts { Publications FBC Staff BCIs Site Map Links Search db a Product Approval r USER:Public User Product Approval Menu>Product or Apoliration Search>Application list>Application Detail FL# C- _.EL--17355 R3�" Application Type Affirmation Code Version 2017-w Application Status Approved Comments Archived ❑ Product Manufacturer Custom Window Systems Inc. Address/Phone/Email 1900 SW 44th Avenue Ocala,FL 34474 (352)368-6922 Ext245 kpine@cws.cc Authorized Signature Kevin Pine kpine@cws.cc Technical Representative Erin Koss Address/Phone/Email 1900 SW 44th Ave. Ocala,FL 34474 (352)368-6922 Ext291 ekoss@cws.cc Quality Assurance Representative Jay Lathrop Address/Phone/Email 1900 SW 44th Ave. Ocala, FL 34474 (352)368-6922 Ext291 jlathrop@cws.cc Category Windows Subcategory Horizontal-Slider---,:..- Compliance Method Certification Mark or Listing Certification Agency Keystone Certifications,Inc. Validated By Steven M. Urich,PE ❑ Validation Checklist-Hardcopy Received Referenced Standard and Year(of Standard) Standard Year AAMA/WDMA/CSA 101/I.S.2/A440-08 2008 ASTM E1300-04 2004 .Equivalence of Product Standards Certified By OI affirm that there are no changes in the new Florida Building Code which affect my product(s)and my product(s)are in compliance with the new Florida Building Code. Documentation from approved Evaluation or Validation Entity OYes ONo ON/A FL17355 R3 COC 6thEdFBC-FL17355.Ddf Product Approval Method Method 1 Option A Date Submitted 09/14/2017 Date Validated 09/14/2017 Date Pending FBC Approval Date Approved 09/15/2017 Summary of Products FL# Model,Number or Name Description 17355.1 HS-620 Vinyl Horizontal Slider XO HS-620 Vinyl Horizontal Slider,XO,Non-impact. Limits of Use Certification Agency Certificate Approved for use in HVHZ:No FL17355 R3 C CAC CAR 138-1315.odf Approved for use outside HVHZ:Yes FL17355 R3 C CAC CAR 138-1316.Ddf Impact Resistant: No FL17355 R3 C CAC CAR 138-1334.Odf Design Pressure: N/A Quality Assurance Contract Expiration Date Other:Max.sizes: 74"x 63"and 74"x 72".See installation 10/16/2018 details for DPs.Glass complies with ASTM E1300-04. Installation Instructions FL17355 R3 II CWS-1031A(HS-620,XO).Odf Verified By: Lucas A.Turner PE-58201 Created by Independent Third Party:Yes Evaluation Reports FL17355 R3 AE EvaIReD CWS-1031A(HS-620,XO).Ddf Created by Independent Third Party:Yes /� 17355:2--,• _ _, HS-620,Vinyl Horizontal 5lider_XOX- HS 620-Vinyl fMorizontal.Slider;_XOX,Non, impact. t� 611 itsof Use"' - "` Certification Agency Certificate Approved for use in HVHZ:No FL17355 R3 C CAC CAR 138-1341.Ddf Approved for use outside HVHZ:Yes FL17355 R3 C CAC CAR 138-1342.Ddf Impact Resistant:No Quality Assurance Contract Expiration Date Design Pressure: N/A 03/30/2019 Other:Max.size 111"x 63".XOX 1/3-1/3-1/3 and Installation Instructions 1/4-1/2-1/4.See installation details for DPs.Glass complies FL17355 R3 II CWS-1067(HS-620,XOX).odf with ASTM E1300-04. Verified By: Lucas A.Turner PE-58201 Created by Independent Third Party:Yes Evaluation Reports FL17355 R3 AE EvaIReD CWS-1067(HS-620,XOX).pdf Created by Independent Third Party:Yes 17355.3 HS-620 Vinyl Horizontal Slider XX HS-620 Vinyl Horizontal Slider,XX,Non-Impact. Limits of Use Certification Agency Certificate Approved for use in HVHZ:No FL17355 R3 C CAC CAR 138-1328.Ddf Approved for use outside HVHZ:Yes FL17355 R3 C CAC CAR 138-1329.Ddf Impact Resistant:No FL17355 R3 C CAC CAR 138-1332.Ddf Design Pressure: N/A FL17355 R3 C CAC CAR 138-1333.Odf Other:Max,sizes: 74"x 63"and 74"x 72". See installation Quality Assurance Contract Expiration Date detail for DPs. Glass complies to ASTM E1300-04. 12/10/2018 Installation Instructions FL17355 R3 II CWS-1059(HS-620,XX).odf Verified By: Lucas A.Turner PE-58201 Created by Independent Third Party:Yes Evaluation Reports FL17355 R3 AE EvalRep CWS-1059(HS-620.XX).Ddf Created by Independent Third Party:Yes Back Next Contact Us::2601 Blair Stone Road.Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275 (1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: LURE RV ® e0lieck 2 GENERAL NOTES: HORIZONTAL SLIDER - NON-IMPACT 1.THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED WINDOW SYSTEMS TO COMPLY WITH THE FLORIDA BUILDING CODE(FBC),CURRENT 1900 SW 44TH AVE. 1121/4"FLANGE WIDTH EDITION. OCALA,FLORIDA 34474 111"MAX.UNIT WIDTH 2.GLAZING OPTIONS:(SEE SHEET 2) WWW.CWS.CC 3611/16" -•-1 3.CONFIGURATIONS:"XOX". MAX.SASH WIDTH - 3611/16" - MAX.SASH WIDTH 4.DESIGN PRESSURE RATING: 620 PVC r32 3/4"GLASS DLO•{ 32 3/4"GLASS DLO -NEGATIVE DESIGN LOADS BASED ON,TESTED PRESSURE AND HORIZ.SLIDER A GLASS TABLES ASTM E-1300-04. NON-IMPACT ------------------------- -—T -POSITIVE DESIGN LOADS BASED ON,TESTED PRESSURE,WATER --- --------------- ---"-- INFILTRATION TEST PRESSURE AND GLASS TABLES _ I ASTM E-1300-04. FLANGE 5.ANCHORAGE:THE 33 1/3%STRESS INCREASE HAS NOT BEEN USED ~¢ HEIGHT IN THE DESIGN OF THIS PRODUCT.SEE SHEET 6 FOR ANCHOR o 63" DETAILS. WINDLOAD DURATION FACTOR Cd=1.6 WAS USED FOR B B MAX. WOOD ANCHOR CALCULATIONS.LIN } �( O �( !"BL 58 71S^HEIGHT 6.NOT APPROVED FOR IMPACT RESISTANCE. IMPACT PROTECTIVE m � MAX. SYSTEM IS REQUIRED IN WIND BORNE DEBRIS REGION. z 1 SASH � HEIGHT 7.ALL FRAMES AND VENTS FULLY WELDED. > 16" Z WSS 8.SERIES/MODEL DESIGNATION HS-620. O DC C � d 9.THE DESIGNATION X AND O STAND FOR THE FOLLOWING: t X=OPERABLE SASH,O=FIXED SASH U U) 010B C A .SECTION CALLOUTS APPLY TO ALL ELEVATIONS IN A SIMILAR 1/3-1/3-1/3 1121/4"FLANGE WIDTH LOCATION. O Z 111"MAX.UNIT WIDTH 2S 1/8" 11.EXTERNAL BOTH ENDS.WEEP SLOT=5116"x 2-1/8"LOCATED 4-1/2"FROM ,p``PNOREW,Tti��i MAX.SASH �.`Q`;:•�C ENS'• ------533/4"MAX.SASH WIDTH----- WIDTH w`O �' F ••y�� —49 13/16"GLASS DLO— 241/4" Z :• No 58201 •.��r GLASS DLO _ Lucas A.Turner f 2015-06-09 =9% STATE OF Pu 641/4" 10:07-04:00 'O FLANGE HEIGHT • O q 1 63" st MAX. q�hs'O�Aells 0 1 UNIT ZZ HEIGHT X O X 68 7/8" 6/8/2015 MAX. SASH LUCAS A.TURNER,P.E. HEIGHT FL PE#58201 55 Ili 6" 1239 JABARA AVE. GLASS NORTH PORT,FL 34288 DLC PH.941-380-1574 SHEET DESCRIPTION: GENERAL NOTES AND 1/4-1/2-1/4 ELEVATIONS TABLE OF CONTENTS DRAWN BY: DATE: GENERAL NOTES&ELEVATIONS.....1 CONFIG. MAX. UNIT SIZE DESIGN PRESSURE RATING IMPACT RATING EMK 06/02/15 DP CHARTS&GLAZING DETAIL........2 DWG 4: REV.: SECTION VIEWS..................................3 XOX 1/4-1/2-1/4 SEE COMPARATIVE ANALYSIS cws-1067 ANCHOR SCHEDULE&NOTES.........5 XOX 1/3-1/3-1/3 111"x 63 CHART, SHEET 2 NONE SCALE: SHEET INSTALLATION DETAILS.....................6 1:25 1 OF 6 DESIGN PRESSURES FOR 1/3-1/3.1/3 CONFIGURATION WITH GLASS TYPE A OR B IN OPERABLE AND FIXED SASH Unit Unit Height Width 171/2 231/2 29112 351/2 411/2 471/2 531/2 591/2 63 WINDOW SYSTEMS 531/2 +50.0/-75.0 +50.0/-75.0 +50.0/-75.0 +50.0/-75.0 +50.0/-75.0 +50.0/-75.0 +50.0/-75.0 +50.0/-75.0 +50.0/-75.0 1900 SW 44TH AVE. 591/2 +50.0/-75.0 +50.0/-75.0 +50.0/-75.0 +50.0/-75.0 +50.0/-75.0 +50.0/-75.0 +50.0/-75.0 +50.0/-75.0 +50.0/-75.0 OCALA,FLORIDA 34474 65 1/2 +50.0/-75.0 +50.0/-75.0 +50.0/-75.0 +50.0/-75.0 +50.0/-75.0 +50.0/-75.0 +50.0/-75.0 +50.0/-74.0 +50.0/-71.3 W W W.CWS.CC 71 1/2 +50.0/-75.0 +50.0/-75.0 +50.0/-75.0 +50.0/-75.0 +50.0/-75.0 +50.0/-75.0 +50.0/-75.0 +50.0/-68.6 +50.0/-64.5 77 1/2 +50.0/-75.0 +50.0/-75.0 +50.0/-75.0 +50.0/-75.0 +50.0/-75.0 +50.0/-75.0 +50.0/-75.0 +50.0/-67.1 +50.0/-61.4 83 1/2 +50.0/-75.0 +50.0/-75.0 +50.0/-75.0 +50.0/-75.0 +50.0/-75.0 +50.0/-75.0 +50.0/-74.7 +50.0/-64.9 +50.0/-60.3 620 PVC 89 1/2 +50.0/-75.0 +50.0/-75.0 +50.0/-75.0 +50.0/-75.0 +50.0/-75.0 +50.0/-75.0 +50.0/-71.5 +50.0/-61.9 +50.01-57.4 HORIZ. SLIDER 95 1/2 +50.0/-75.0 +50.0/-72.5 +50.0/-67.9 +50.0/-67.5 +50.0/-67.5 +50.0/-67.5 +50.0/-67.5 +50.0/-59.3 +50.0/-54.9 NON-IMPACT 101 1/2 +50.0/-75.0 +50.0/-65.9 +50.0/-60.8 +50.0/-59.8 +50.0/-59.8 +50.0/-59.8 +50.0/-59.8 +50.0/-57.1 +50.0/-52.8 111 +50.0/-69.2 +50.0/-57.7 +50.0/-52.1 +50.0/-50.1 +55 0/-50.0 +50.0/-50.0 +50.0/-50.0 +50.0/-50.0 +50.0/-50.0 w DESIGN PRESSURES FOR 1/4-1/2-1/4 CONFIGURATION WITH GLASS TYPE A OR B IN OPERABLE SASH,GLASS TYPE B IN FIXED SASH Unit Unit Height Width 171/2 231/2 291/2 351/2 411/2 471/2 531/2 591/2 63 } 531/2 +50.0/-67.5 +50.0/-67.5 +50.0/-67.5 +50.0/-67.5 +50.0/-67.5 +50.0/-67.5 +50.0/-67.5 +50.0/-67.5 +50.0/-67.5 m 591/2 +50.0/-67.5 +50.0/-67.5 +50.0/-67.5 +50.0/-67.5 +50.0/-67.5 +50.0/-67.5 +50.0/-67.5 +50.0/-67.5 +50.0/-66.2 Z 65 1/2 +50.0/-67.5 +50.0/-67.5 +50.0/-67.5 +50.0/-67.5 +50.0/-67.5 +50.0/-67.5 +50.0/-67.5 +50.0/-66.3 +50.0!-61.6 O 71 1/2 +50.0/-67.5 +50.0/-67.5 +50.0/-67.5 +50.0/-67.5 +50.0/-67.5 +50.0/-67.5 +50.0/-67.5 +50.0/-62.5 +50.0/-57.9 Ln 77 1/2 +50.0/-67.5 +50.0/-67.5 +50.0/-67.5 +50.0/-67.5 +50.0/-67.5 +50.0/-67.5 +50.0/-67.5 +50.0/-59.3 +50.0/-54.9 w 83 1/2 +50.0/-67.5 +50.0/-67.5 +50.0/-67.5 +50.0/-67.5 +50.0 1-67.5 +50.0/-67.5 +50.0/-66.1 +50.0/-56.7 +50.0/-52.3 Q 89 112 +50.0/-67.5 +50.0/-67.5 +50.0/-67.5 +50.0/-67.5 +50.0/-67.5 +50.0/-67.5 +50.0/-63.8 +50.0/-54.5 +50.0/-50.2 a 95 1/2 +50.0/-65.5 +50.0/-60.8 +50.0/-60.8 +50.0/-60.8 +50.0/-60.8 +50.0/-60.8 +50.0/-60.8 +50.0/-52.7 +48.4/-48.4 v 101 112 +50.0/-59.6 +50.0/-54.1 +50.0/-53.8 +50.0/-53.8 +50.01-53.8 +50.0/-53.8 +50.0 1-53.8 +50.0/-51.2 +46.9/-46.9 w 111 +50.0/-52.1 +46.1/-46.1 +45.0/-45.0 +45.0/-45.0 +45.0/-45.0 +45.0/-45.0 +45.0/-45.0 +45.0/-45.0 +45.0/-45.0 NOTE:GLASS TYPE B REQ'D FOR FIXED SASH WIDTHS LARGER THAN 36-11/16" Z 7/8"OVERALL 7/8"OVERALL ,5`P DREW Il,���i 1/8"ANNEALED or TEMPERED [�T-3/16" ANNEALED or TEMPERED---9/16"AIRSPACE 7/16"AIRSPACE No1/8"ANNEALED or TEMPERED 3/16"ANNEALED or TEMPERED i�T�•A.�O R 1 C1 P,•����. 5/8"GLASS BITE 5/8"GLASS BITE 6/8/2015 1 LUCAS A.TURNER,P.E. FL PE#58201 1239 JABARA AVE. NORTH PORT,FL 34288 PH.941-380-1574 SHEET DESCRIPTION: DP CHARTS AND GLAZING DETAILS DRAWN BY. DATE: GLASS TYPE A GLASS TYPE B EMK 06/02/15 DWG#.RREV.: CWS-1067 - NOTE:IF SIZE INTENDED IS NOT SHOWN,USE NEXT LARGER SIZE. SCALE' SHEET 1:1 2 OF 6 26 3 2 27 13 INTERIOR1)T18 3 11 WINDOW SYSTEMS 1900 SW 44TH AVE. FLO 34474 www.. wS.cC 14 620 PVC 8 HORIZ.SLIDER NON-IMPACT -t o w @) 19 31 :c�:0 a) 0 SECTION VIEW B-B z 1 0 9 > 3 32 2 0 p 4 4 33 24 w 1 1""s i Ot oil I oz': 11�01 P*O tv 33 32 0(41 21 0 ...... 6/8/2015 LUCAS A.TURNER,P.E. FL PE#58201 1239 JABARA AVE, ❑ NORTH PORT,FL 34288 PH.941-380-1674 SHEET DESCRIPTION: SECTION VIEWS SECTION VEW XA DRAWN BY: DATE: EMK 06/02/15 SECTION VIEW C-C DWG#: REV.: ALTERNATE FIN FRAME CWS-1067 - TcALC_ SHEET 12 30F6 6"MAX.(TYP.) (II- --} 14 1/2'MAX.O.C.(TYP.) 6"MAX.(TYP.) I ------ 1­-4''(TYP.) CENTANCHOR RLI MNE TGYp j IL WINDOW SYSTEMS V- V'liAyL4lSU • 1900 SW 44TH AVE. INSTALLATION OCALA,FLORIDA 34474 ANCHOR(TYP.) WWW.CWS.CC 4"MAX.(TYP.) III.-III--B"MAX.O.G.(TYP.) 4"THRU FRAME ANCHOR(TYP.) 1 B" SEE NOTE 2 HO 620IZ.PVC DER 4"MAX.(TYP.) I I MAX.O.C. X O X r SEE NOTE 2 (TYP.) INSTALLATION NON-IMPACT ANCHOR(TYP.) � a w MAX.O.C. o (TYP.) X O X ANCHOR LAYOUT-(FLANGE) m 1/3-1/3-1/3 Z O ANCHOR @ MTG RAIL--------- Z a W CENTERLINE(TYP.) ---4"(TYP.) 0 cc MAX.(TYP.) 13 1!4"MAX.O.C. a: FT (TYP-) ¢ 6"MAX.(TYP.)� 0 ANCHOR LAYOUT-(FIN) w 1/4-1/2-1/4 and 1/3-113-113 --INSTALLATION NOTE THRU FRAME ANCHORS @ MTG RAIL ANCHOR(TYP.) p z ��1,��►n�l+rpr SEE NOTE 2 �ADRE `�����P, Vy TIJ p, r: MAX.O.C. X O X `��GP•�\CENS��,•.,�Pti��� (TYP.) No 5B201 ;ate NOTES: :13 STATE OF 004 1.INSTALL ONE ANCHOR AT EACH INSTALLATION LOCATION.SILL ANCHOR SPACING SAME AS HEAD. SrONA��? 2.SHIM AS REQ AT EACH INSTALLATION ANCHOR USING LOAD BEARING SHIMS. MAX.ALLOWABLE SHIM STACK TO BE 114". (FLANGE) LAYOUT-(FLANGE) 7 USE SHIMS WHERE SPACE GREATER THAN 1116"IS PRESENT. LOAD BEARING SHIMS SHALL BE CONSTRUCTED OF HIGH ANC 1/4- - �f— DENSITY PLASTIC OR BETTER.WOOD SHIMS ARE NOT ALLOWED. 6/8/2015 3.ANCHOR TYPE,SIZE,SPACING AND EMBEDMENT SHALL BE AS SPECIFIED IN THESE DRAWINGS,SEE TABLE 1,SHEET 6. LUCAS A.TURNER,P.E. 4.ALL INSTALLATION ANCHORS MUST BE MADE OF OR PROTECTED WITH A CORROSION RESISTANT MATERIAL OR COATING. DISSIMILAR METALS OR MATERIALS IN CONTACT WITH PRESSURE TREATED WOOD MUST FL PE#58201 BE PROTECTED TO PREVENT REACTION. 1239 JABARA AVE. NORTH PORT,FL 34288 5.INSTALLATION ANCHORS SHALL BE IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS,AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM PH.941-380-1574 SPECIFIED IN TABLE 1,SHEET 6. SHEET DESCRIPTION: 6.ANCHOR EMBEDMENT TO SUBSTRATE SHALL BE BEYOND WALL DRESSING OR STUCCO. FOR CONCRETE/CMU OPENINGS,EMBEDMENT SHALL BE BEYOND WOOD BUCKS,IF USED,INTO SUBSTRATE-1 X BUCKS ARE ANCHOR SCHEDULE AND OPTIONAL. NOTES 7.A MINIMUM CENTER-TO-CENTER SPACING SHALL BE MAINTAINED BETWEEN ALL FASTENERS:3-9/16"FOR MASONRY,1"FOR WOOD AND METAL. DRAWN BY: DATE: EMK 06/02/15 8.WOOD OR MASONRY OPENINGS,BUCKS AND BUCK FASTENERS SHALL BE PROPERLY DESIGNED BY THE ARCHITECT OR ENGINEER OF RECORD AND INSTALLED TO TRANSFER WIND LOADS TO THE STRUCTURE. DWG 4: NEV.: SUBSTRATES SHALL MEET THE MINIMUM STRENGTH REQUIREMENTS AS SHOWN IN TABLET,SHEET 6. CONCRETE AND MASONRY SUBSTRATES MAY NOT BE CRACKED. CWS-1067 9.SEALING AND FLASHING STRATEGIES FOR OVERALL WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS FOLLOWING THE CURRENT VERSION OF THE REFERENCE DOCUMENTS: SCALE: SHEET FMAIAAMA 100(FIN WINDOWS),FMAIAAMA 200(FLANGE WINDOWS), FMAANDMA 250(BOX WINDOWS),FMA/AAMAANDMA 300(EXTERIOR DOORS) 1:20 50176 MIN.EMBEDMENT �j� SEE TABLE 1 SUBSTRATE !( ]]/J(��®/�j]' TYPICAL HEAD ANCHORAGE BY OTHERS ��JCriYAUll44 UU(.f� 114"MAX.SHIM - SEE TABLE 1 WINDOW SYSTEMS MIN.EDGE DIST. MIN.EDGE DIST. SUBSTRATE -I- SEE TABLE 1 BY OTHERS OCA A, AVE. SEE TABLE 1 1/4"MAX.SHIM SEE TABLE 1 www.CWS.CC FLORIDAORI 34474 SUBSTRATE BY OTHERS MIN.EDGE DIST. www.cws.cc W. SEE TABLE 1 �� SEE TABLE 1 S E TAB EDI INSTALLATION ANCHOR — ��❑ 620 PVC PERIMETER SEALANT SEE TABLE 1 BY INSTALLER I HORIZ.SLIDER INSIDE AND OUT p / -"1----------- MIN.EMBEDMENT L�7 O SEALANT BEHIND SEE TABLET NON-IMPACT �� FLANGE BY INSTALLER 1/4"MAX.SHIM oe . Qeo PERIMETER SEALANT (- PERIMETER SEALANT Q BY INSTALLER eve BY INSTALLER Lc INSIDE AND OUT INSIDE AND OUT INSTALLATION ANCHOR } SEALANT BEHIND SEE TABLE 1 op FLANGE BY INSTALLER SEALANT BEHIND INSTALLATION ANCHOR FIN BY INSTALLER Z SEE TABLE 1 B HORIZONTAL SECTION C HORIZONTAL SECTION 6 TYPICAL JAMB ANCHORAGE 6 TYPICAL FIN ANCHORAGE co HEAD AND SILL SIMILAR FOR FIN INSTALLATION Z W O LU NOTE:ADDITIONAL THRU-FRAME ANCHORS a (AS SHOWN IN DIET.A/6)REQ'D AT MTG RAIL, D[ SEE SHEET 5 ANCHOR LAYOUT. ai w 0 O SEALANT BEHIND r 1/4"MAX.SHIM z " 1 FLANGE BY INSTALLER 0� , PtiyDREW'Tlk�� PERIMETER SEALANT , MIS EMBEDMENT '.JOP`;.��0 E NSA G�p2 BY INSTALLER SEE TABLE 1 No 58201 :-P INSIDE AND OUT oo SUBSTRATE BY OTHERS MIN.EDGE DIST. '9•: STATE OF .4u SEE TABLE i SEE TABLE 1 0 ,� P,�•�4C/, SEALANT UNDER SCREW A VERTICAL SECTION �i�CcS• O..10• ����� HEAD BY INSTALLER 6 TYPICAL SILL ANCHORAGE oo ���•,S+ONp� � z� TABLE 1:APPROVED INSTALLATION FASTENERS 6/8/2015 FRAME TYPE SUBSTRATE TYPE ANCHOR TYPE MIN.EMBEDMENT MIN.EDGE DIST. LUCAS A.TURNER,P.E. PE FLANGE CONCRETE(2.0 KSI MIN.) 3116"ITW TAPCON 1" 1-1/8" # A Al � 1239 JABAR AVE. FLANGE HOLLOW OR GROUT-FILLED CMU(117 PCF MIN.) 3/16"ITW TAPCON 1" 2" PERIMETER SEALANT ' NORTH PORT,FL 34288 FLANGE CONCRETE(2.85 KSI MIN.) 3/16"ELCO ULTRACON 1" 1" BY INSTALLER PH.941-380-1574 INSIDE AND OUT D H_ SEC TION CTION ____ FLANGE GROUT-FILLED CMU(ASTM C-90) 3116"ELCO ULTRACON 1-3/4" 2.1/2" 6_ __80X RA FME INSTALLATION SHEET DESCRIPTION: 3/16"ITW TAPCON SIMILAR FOR HEAD AND SILL FOR BOX INSTALLATION FLANGE 2XMIN.SOUTHERN PINE(G=0.55) OR ELCO ULTRACON 1 3/8 7/8" INSTALLATION DETAILS FLANGE 2XMIN.SOUTHERN PINE(G=0.55) #10 WOOD SCREW 1-3/8" 7/8" FLANGE REMOVAL NOTE:PARTIALLY OR FULLY REMOVING THE FLANGE, DRAWN BY: DATE: 16 GAUGE(0.060")MIN.STEEL STUD #10-16 HILTI KWIK-FLEXOR I1W FULL THREAD UP TO AND INCLUDING A BOX-FRAME APPLICATION IS ACCEPTABLE PROVIDED: FLANGE (33 KSI YIELD MIN) TEKS SELF-DRILLING SCREW THRU 0.060" 7/16" EMK 06/02/15 MIN.1/4"FILLET OF CONSTRUCTION-GRADE ADHESIVE CAULK IS APPLIED DWG 4: REV.: 1/8"ALUM.(6063-T5 MIN.)OR #10 GRADE 5 SELF-TAPPING/ FULL THREAD INSIDE AND OUT,FULL PERIMETER,BY INSTALLER. C W S-1067 FLANGE 7/16" 1/8"STEEL(33 KSI MIN.) DRILLING SCREW THRU 0.125" -PRODUCT ANCHORAGE IS IN ACCORDANCE WITH REQUIREMENTS AS FIN 2X MIN.SOUTHERN PINE(G=0.55) #10 WOOD SCREW 1-1/2" 1/2" SHOWN FOR FLANGE WINDOWS. SCALE: SHEET 1:2 6OF6 Businessbl— ♦ ' 1 l oRegulationnr. _ BCIS Home I Login I User Registration Hot Topic Submit Surcharge ; Stats&Facts I Publications FBC Staff BCIS Site Map i Links I Search Florida 21. Product Approval r �11 USER:Public User L. Product Approval Menu>Product or Aoolication Search>Aoolication List>Application Detail FL# �,-EL1-7273=R2 Application Type Revision.. Code Version �=2017 Application Status Approved----- . Comments Archived ❑ Product Manufacturer Vi Win Tech Address/Phone/Email 2400 Irvin Cobb Drive Paducah,KY 42003 (270)538-4431 swheeler@viwintech.com Authorized Signature Steven Wheeler swheeler@viwintech.com Technical Representative Steve Wheeler Address/Phone/Email 2400 Irvin Cobb Dr Paducah,KY 42003 (270)538-4431 swheeler@viwintech.com Quality Assurance Representative Ronnie WIlliams Address/Phone/Email 2400 Irvin Cobb Dr Paducah,KY 42003 (270)538-4437 rwi�lliams@viwintech.com Category Windows✓f Subcategory ions Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ❑ Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed Robert].Amoruso,P,E. the Evaluation Report Florida License PE-49752 Quality Assurance Entity National Accreditation and Management Institute Quality Assurance Contract Expiration Date 12/31/2018 Validated By Steven M. Urich,PE O Validation Checklist-Hardcopy Received Certificate of Independence FL17273 R2 COI FLCOI,Ddf Referenced Standard and Year(of Standard) Standard Year TAS 201 1994 TAS 202 1994 TAS 203 1994 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 01/12/2018 Date Validated 02/21/2018 Date Pending FBC Approval 03/11/2018 Date Approved 06/12/2018 Summary of Products FL# Model,Number or Name Description 17273.1 ----ShoreLine.3".Impact Mullion_._ _____- Mull,1.5'-',x,3",Heavy_Aluminum with clips.Vertical,T and,- Horizontal configurations Y - r Limits of Use Installation Instructions Approved for use in HVHZ:No FL17273 R2 II 08-00237C.Ddf Approved for use outside HVHZ:Yes Verified By: Luis Roberto Lomas FL PE No.: 62514 Impact Resistant:Yes Created by Independent Third Party: Yes Design Pressure:N/A Evaluation Reports Other:See Installation Drawing for Mull Span/Load Width FL17273 R2 AE 510308C.Ddf Design Pressure Tables. Created by Independent Third Party:Yes Back Next Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275 (1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: ,Mrt- ® g - Credit Card Safe 161 REVISIONS REV DESCRIPTION DATE APPROVED C REVISED PER NEW REQUIREMENTS 01/12/18 R.L. NOTES: 1) THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH REQUIREMENTS OF FLORIDA BUILDING CODE INCLUDING THE HVHZ 2) WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 3) CONTRACTOR IS RESPONSIBLE FOR MAINTAINING STRUCTURAL INTEGRITY OF WINDOW OPENING AND ALL WOOD FRAMING AROUND WINDOW. 4) RESPONSIBILITY OF SELECTING FENESTRATION PRODUCTS TO MEET ANY APPLICABLE LOCAL LAWS, BUILDING CODES, ORDINANCES OR OTHER SAFETY REQUIREMENTS REST SOLELY WITH THE ARCHITECT, ENGINEER OF RECORD, BUILDING OWNER OR CONTRACTOR. 5) APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED FOR THIS PRODUCT IN WIND BORNE DEBRIS REGIONS. 6) DESIGN PRESSURE AND INSTALLATION DETAILS SHOWN IN THIS DOCUMENT APPLY ONLY TO THE MULLION. WINDOWS MUST BE APPROVED UNDER SEPARATE APPROVAL. 7) SINGLE UNITS TO BE MULLED ARE NOT LIMITED TO THOSE SHOWN IN THIS DRAWING. SINGLE UNITS TO BE MULLED TOGETHER MUST BE MANUFACTURED BY VINYL WINDOW TECHNOLOGIES, INC. AND MUST BE MADE OUT OF VINYL PVC. 8) DESIGN PRESSURE OF MULLED UNIT SHALL BE CONTROLLED BY THE LESSER DESIGN PRESSURE OF THE MULLION OR THE INDIVIDUAL WINDOW UNIT. 9) TWIN CONFIGURATION SHOWN. UNITS MAY BE MULLED TOGETHER INDEFINITELY AS LONG AS THE SINGLE UNIT WIDTH AND THE SINGLE UNIT HEIGHT ARE NOT EXCEEDED AND MULLION IS ANCHORED AS SHOWN HEREIN. 10) MULLION VERTICAL INSTALLATION IS SHOWN, MULLION MAY BE USED IN HORIZONTAL APPLICATIONS AS LONG AS DIMENSIONS INDICATED HEREIN ARE NOT EXCEEDED AND MULLION IS ANCHORED ACCORDING TO THIS DOCUMENT. 11) ALLOWABLE STRESS INCREASE OF 1/3 WAS NOT USED IN THE DESIGN OF THE PRODUCT SHOWN HEREIN. WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. SIGNED:0111212018 VIWINTzaao RvCH NDO COBBIN DRDEDOORS \`\\\r lR 1!<<d PADUCAH, KY 42003-0588 `�,•4\GENSF'9,p/� SHORELINE 3" IMPACT MULLION *,•/�10j'�51 VERTICAL AND HORIZONTAL C � NOTES �� $TAT OF•�� TABLE OF CONTENTS ���`�•R P DRAWN: DWG N0. REV SHEET NO. DESCRIPTION RA E DATE 08 500237 c �pNA�/it I III tEN�\\\ 1 VERTICAL MULLION ELEVATION AND GENERAL NOTES NTS 09/05/07 1 OF 5 2 HORIZONTAL VERTICAL/HORIZONTAL MULLION ELEVATION L.ROBERTOLOMASP.E Luis R. Lomas P.E. f432 WOODFORD RD LEWISVILLE,NO 27023 FL No.: 62514 3 B.O.M. COMPONENTS AND INSTALLATION DETAILS 434-666-0609 rllomas@Irlomaspe.com REVISIONS 73 7/8" MAX. O.A. WIDTH REV DESCRIPTION GATE -PROVED W1 Ql� W2 C REVISED PER NEW REQUIREMENTS 01/12/18 R.L. SINGLE WINDOW WIDTHSINGLE WINDOW WIDTH 6" SEE DETAIL A j MAX. MULLION SPAN (WINDOW HEIGHT) 9" MAX. O.C. DESIGN PRESSURE TABLE INSTRUCTIONS: III 1 DEFINE REQUIRED DESIGN LOAD PER FLORIDA BUILDING CODE CHAPTER 16. 6 2. DETERMINE TRIBUTARY WIDTH AND MULLION SPAN BASED ON MAX. PRODUCT TO BE INSTALLED. SEE FORMULA FOR TRIBUTARY SEE DETAIL A WIDTH. 3. LOCATE MULLION SPAN (UNIT HEIGHT) AND TRIBUTARY WIDTH. AT 3"IMPACT MULLION VERTICAL THE INTERSECTION OF ROW AND COLUMN CONTAINING THE MULLION SPAN AND TRIBUTARY WIDTH RESPECTIVELY IS THE MULLION RATING FOR PRODUCT IN STEP 2. MULLION RATING MUST BE EQUAL OR GREATER THAN REQUIRED DESIGN PRESSURE OBTAINED IN STEP 1. Chart#1 Design pressure rating(psi H 1 + H 2 posl0veand negative TRIBUTARY HEIGHT= 2 Mullion Tributary width(in) span(In) 36.00 38.00 40.00 142.00 44.00 46.00 48.00 50.00 52.00 52.00 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 80.0 54.00 80.0 80.0 80.0 80.0 79.6 78.2 77.1 76.3 75.9 56.00 80.0 78.8 76.4 74.3 72.5 71.1 69.9 69.0 68.4 58.00 73.3 70.8 68.6 66.8 65.2 63.9 62.9 62.0 61.4 SIGNED:0111212018 60.00 65.5 63.2 61.1 59.4 57.9 56.7 55.6 54.8 54.1 62.00 58.8 56.6 54.7 53.1 51.7 50.5 49.5 48.6 47.9 VIWINTECH WINDOWS AND DOORS 'to// 2400 66.00 47.9 46.0 44.4 43.0 41.8 40.7 39.7 38.9 38.2 PADUCAH IIKY COBB 0588 ��RIVE \vJ\'�CENS'�1,,� 68.00 43.5 41.8 40.2 38.9 37.8 36.7 35.8 35.1 34.4 v F 70.00 39.6 38.0 36.6 35.3 34.3 33.3 32.5 31.7 31.1 SHORELINE 3" IMPACT MULLION *• 0y6/26�1 72.00 36.2 34.7 33.4 32.2 31.2 30.3 29.5 28.8 28.2 VERTICAL AND HORIZONTAL 74.00 33.1 31.7 30.5 29.4 28.5 27.6 26.9 26.2 25.6 VERTICAL ELEVATION ��0, TAT E OF •40 76.00 30.4 29.1 28.0 27.0 26.1 25.3 24.6 23.9 23.4 DRAWN: DWG NO. REV �'t`F•:c�CR10Q;•��'�� 78.00 28.0 26.8 25.7 24.8 24.0 23.2 22.5 21.9 21.4 R.L. 08-00237 C ��/sis/0 �C�G\\\ 80.00 25.8 24.7 23.7 22.8 22.1 21.3 20.7 20.2 19.7 SCALE DATE SHEET / 01VA j E:� � Large and Small Missile Impact level D,wind Zone and HVHZ NTS 09/05/07 2 OF 5 L ROBERTO LOMAS P.E. LUIS R. Lomas P.E. 1432 WOODFORD RD LEWISVILLE,NC 27023 434-686-0609 rllomasC@Momaspe.com FL No.: 62514 REVISIONS MULLION SPAN REV DESCRIPTION DATE APPROVED _ C REVISED PER NEW REQUIREMENTS 01/12/18 R.L. SEE H2 DETAIL B 9" MAX. SEE DETAIL C (TRANSOM O.C. HEIGHT) 6 SEE MAX. DETAIL B H, (WINDOW DESIGN PRESSURE TABLE INSTRUCTIONS: HEIGHT) 1. DEFINE REQUIRED DESIGN LOAD PER FLORIDA BUILDING CODE CHAPTER 16. 2. DETERMINE TRIBUTARY HEIGHT AND MULLION SPAN BASED ON PRODUCT TO BE INSTALLED. SEE FORMULA FOR TRIBUTARY HEIGHT. 9 3. LOCATE MULLION SPAN AND TRIBUTARY HEIGHT. AT THE MAX. O.C. 6" INTERSECTION OF ROW AND COLUMN CONTAINING THE MULLION MAX. SPAN AND TRIBUTARY HEIGHT RESPECTIVELY IS THE MULLION III RATING FOR PRODUCT IN STEP 2. MULLION RATING MUST BE 7q EQUAL OR GREATER THAN REQUIRED DESIGN PRESSURE Jf - OBTAINED IN STEP 1. 36" SEE DETAIL A TRIBUTARY HEIGHT= H1 + H2 2 3"IMPACT MULLION T HORIZONTAL Chart#3 Design pressure rating(pso positive and negative Tributary Mullion span(in) height 34.00 36.00 1 38.00 40.00 42.00 44.00 46.00 48.00 50.00 30.00 96.6 82.6 68.0 56.7 47.9 40.8 35.1 30.4 26.6 32.00 95.1 81.0 66.3 55.1 46.3 39.3 33.8 29.2 25.4 34.25 94.6 80.0 65.1 53.7 45.0 38.1 32.5 28.1 24.4 36.00 94.6 79.7 64.5 53.0 44.2 37.3 31.8 27.3 23.7 SIGNED:0111212018 38.00 94.6 79.7 64.3 52.5 43.6 36.6 31.1 26.7 23.1 42.00 94.6 79.7 T64.352.3 3 43.1 35.8 30.2 25.7 22.6 VWINT24 o RvNDOWIN OeBADRDEDOORS \J\51R111/o9/// 44.00 94.6 79.7 3 43.1 35.6 30.0 25.5 21.8 PADUCAH, KY 42003-0588 `v••v�GENS�;•S 46.00 94.6 79.7 3 43.1 35.8 29.9 25.3 21.6 fit• 0 GO-F 46.00 94.6 79.7 3 43.1 35.8 29.9 25.2 21.5SHORELINE 3" IMPACT MULLION VERTICAL AND HORIZONTAL50.00 94.6 79.7 3 43.1 35.8 29.9 25.2 21.4 T MULLION ELEVATION �1J TAT •�` 52A0 94.6 79.7 3 43.1 35.8 29.9 25.2 21.4 p� tV` 54.00 94.6 79.7 3 43.1 35.8 29.9 25.2 21.4 DRAWN: DWG NO. REVjs58.00 94.6 79.7 3 43.1 35.8 29.9 25.2 21.4 BALE DATE 08 SHEET3 C ��iijr�ONA;1������ 60.00 94.6 79.7 64.3 52.3 43.1 35.8 29.9 25.2 21.4 NTS 09/OS/07 3 OF 5 62.00 1 94.6 1 79.7 64.3 52.3 1 43.1 1 35.8 29.9 1 25.2 21.4 L.ROBERTO LOMAS P.E. Luis R. Lomas P.E. Large and Small Missile Im act Level D,wind Zone and HVHZ 1432WOODFORD RDLEWISVILLE,NC27023 FL No.: 62514 r9 P 434-688-0609 rllomas@Ulomaspe.mm r PARTS LIST _ MIN. EDGE REVISIONS NO. PART NUMBER DESCRIPTION SUBSTRATE -{I DISTANCE SEE REV DESCRIPTIONDATE APPROVED• 1 3" IMPACT MULLION, ALUMINUM BY OTHERS NOTES THIS PAGE SEE NOTES C REVISED PER NEW REQUIREMENTS 01/12/18 R.L. 2 05-053 CLIP FOR ANCHOR TYPE SEE NOTES FOR MIN. EMB. `J ANCHORING NOTES: 1.375" 1 1) FOR ANCHORING INTO MASONRY USE 3/16" TAPCONS WITH SUFFICIENT #10 5' 1.075" TEK SCREWS LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS DETAIL A AND INSTALLATION DETAILS. TOPANDBOTTOMCLIPINSTALLATION 2) FOR ANCHORING INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD SCREW WITH SUFFICIENT LENGTH TO ACHIEVE A 1 3/8" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 1/2" MINIMUM EDGE DISTANCE. LOCATE 2.8" 1.55" SEE NOTES ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. rFOR MIN. EMB. 3) FOR ATTACHING WINDOW UNITS TO MULLION USE #10 TEK SELF TAPPING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A MINIMUM EMBEDMENT OF THREE THREADS PAST THE MULLION WALL WITH 1/2" MINIMUM EDGE 2 ` ` DISTANCE. LOCATE SCREWS AS SHOWN IN ELEVATIONS AND INSTALLATION #10 TEK SCREWS SEE NOTES FOR DETAILS. ANCHOR TYPE O3"IMPACT MULLION 4 FOR ATTACHING VERTICAL MULLION TO HORIZONTAL MULLION USE #10 TEK 6063-T6ALUMINUM SELF TAPPING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A MINIMUM EMBEDMENT OF THREE THREADS PAST THE MULLION WALL. LOCATE SCREWS SUBSTRATE AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. \ BY OTHERS ` 5) FOR WINDOW UNITS ANCHORING SCHEDULE REFER TO WINDOW APPROVED 1 INSTALLATION INSTRUCTIONS. 6.05" \\\\ MIN. EDGE 6) ALL FASTENERS TO BE CORROSION RESISTANT. DISTANCE SEE 1.75" - - 1.75" NOTES THIS PAGE 7) INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH 375" 375" ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE 375" DETAIL B MINIMUM STRENGTH SPECIFIED BELOW. SIDE CLIP INSTALLATION 8) INSTALLATION ANCHOR CAPACITIES FOR PRODUCTS HEREIN ARE BASED ON SUBSTRATE MATERIAL WITH THE FOLLOWING PROPERTIES: A. WOOD - MINIMUM SPECIFIC GRAVITY OF G=0.42 1.49" .74" B. CONCRETE - MINIMUM COMPRESSIVE STRENGTH OF 3,200 PSI. C. MASONRY - STRENGTH CONFORMANCE TO ASTM C-90, GRADE N, TYPE 1 (OR GREATER). 1.015" 01/4" #10 TEK SCREWS fff SIGNED:01/12/2018 VIWINT2aoo RvCH NDOWS IN oee DRDEDOORS `N���\giRII'L/p �ii,� 3.125" 7--// OPADUCAH, KY 42003-0588 •��GENq 'pSHORELINE 3" IMPACT MULLION ��t�• /�1 61VERTICAL AND HORIZONTAL �Q�{y�125 #10 TEK SCRINSTALLATION DETAILS �g1••, $$TAT OF [v` DRAWN: DWG N0. REV %�L 'c�s:cCpR10Q;G���� HORIZONTAL AND DETAIL C ERTICALMULLION ALE onrE 08500237 C - '/,�/S,pNAj1 N � OCLIP INTERSECTION CLIP INSTALLATION NTS 09/05/07 5 OF 5 6063-T6 ALUMINUM L.ROBERTO LOMAS P.E. 1432 WOODFORD RD LEWISVILLE,NC 27023 Luis R. Lomas P.E. 434-668-0609 rllomas@frlomaspe.com FL No.: 62514 1LIH . City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: �� Date Received: Site: �7 Permit Type: i �0 u,/ z &1 Approved Who comments:❑ Approved w/the below comments: Denied w/the below comments: O S-ee dLe Z, This comment sheet shall be kept with the permit and/or plans. Kalvin S itzer 1 xaminer Date on ctor an&or Homeowner equired when comments are present) 201.8105004 rtcpt:1�67525 Ree: 10.00 DS: 0.00 IT: 0.00 Permit Number 06/21/2018 C. F. , Dpty Clerk Parcel ID Number 35'a 1-(� �'f�C �� �l��� "PULP s.0'NEIL,Ph.D.PRS66 CLERK & COMPTROLLER NOTICE OF COMMENCEMENT 06/21/2018 10:48am 1 of i CAR BK 9744 PG 3322 State of Florida County of Pinellas THE UNDERSIGNED hereby gives notice that improvements will be made to certain real property, and in accordance with Section 713.13 of the Florida Statutes,the following information is provided in this NOTICE OF COMMENCEMENT. 1.Description of property(legal description): � a)Street(job)Address: 7 el ( f P Pt_�G-01. 2. �� P� Y P H��c �__3 _- 2.General description of improvements: ._-._.._CJf' -_ 3,Owner Information or Lessee information if the Lessee contracted for the improvement: �a)Name and address: s p_L�C i, A, N yt�S_—��i 1 -A Z��(f_V_ -fit�5.�.��_3 b)Name and address of fee simple titleholder(if different than Owner listed above) _ _ — ___ —__-•_l.�3� �c)Interest in property: - 4,Contractor Information a)Name and address: Lipton Window and Door,2438 Merchant Ave,Odessa,FL.33556 b)Telephone No.: 727-372-2455 Fax No.:(optional) _ 5,Surety(if applicable,a copy of the payment bond is attached) a)Name and address: b)Telephone No.: c)Amount of Bond: $ — i __..__.__-_ 6.Lender a)Name and address: b)Telephone No.: 7.Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)T.Florida Statutes: a)Name and address: b)Telephone No.: Fax No.:(optional) 8.a.ln addition to himself or herself,Owner designates _ — _—_— _ of to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statutes, b)Phone Number of Person or entity designated by,Owner: 9.Expiration date of notice of commencement(the expiration date may not be before the completion of construction and final payment to the _contractor,but will be 1 year from the date of recording unless a different date is specified): _ 20 _ WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I,SECTION 713,13,FLORIDA STATUTES,AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION, IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT, Under penalty of perjury,I declare that I have read the foregoing notice of commencement and that the facts stated therein are true to the best of my knowledge belief. (Signature of Owner or Lessee,or wners or Lessee's(Authorized OfficerlDirectorlPartnedManager) (Print tTame and Provide Signatory's Title/Office) The foregoing instrument was acknowledged before me this d-� l day of _(1'LC, __ _ .-_._- . ,20 by �-1.!!_Yers ---•--- as 11.L'.'r-- tip of authority,e.g.officer,trustee,attorney in fact) for as _ (Name of Person) (type of authority,...e.g.officer,trustee,attorney in fact) for (name of party on behalf of whom instrument was executed). Personally Known ❑' Produced-ID- - Type of lD (h 6 gtv ��G�_ L/^���'=r� Notary Signature Print name LT__.��i�// .- _ � _......- -- --- -- - .��Rrvy@, JAMES KEVIN HOWELL --- -- X-4 MY COMMISSION ItFF914360 � EXPIRES August 31,2019 t407)39e 0153 FtoridallotarySerr m,mm 4 A ' a � fop 13 STATE OF FLORIDA,COUNTY OF PASCO THIS IS TO CERTIFY THAT THE FOREGOING IS A TRUE AND CORRECT COPY OF THE DOCUMENT ON FILE OR OF P LI ECORD IN THIS OFFICE W��ITN�jSS MY HA D AND FFICIAL SEAL THI c DAY OF PAULA S.O'NEIL., R &CO OLLE BY �—�) DEPUTY CLERK l./ I P an' Review Windows & Doors . 1): :Need manufacturing installation specifications: 2). Must meet sections R308 and R612 of the 2017 F:B.C: 3): If windows are to be installed-inside the historical district,they.will heed to be approved: by the historical committee.. 4) No other work shall be permitted (framing; plumbing;and mechanical) unless otherwise' specified.: 5) This is-for replacement_(glass for-glass.) only. if you.wish to.change from screen.or vinyl windows to glass;then additional information is required.: 6) All-windows to-wall connectio.ns:shall be left,visible for. inspection. 7,) All Labeling , ndatickers shall remain on windows until final inspection: . :. 81' No work shall start without permit first: ::