HomeMy WebLinkAbout18-19881 CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 19881 FIRE ALARM SYSTEM PERMIT PERM IT-INFORMATIOW- -LOCATION=INFORMATION / Permit Number: 19881 Address: 7920 GALL BLVD Permit Type: FIRE ALARM SYSTEM ZEPHYRHILLS, FL. Class of Work: FIRE ALARM SYSTEM Township: Range: Book: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Square Feet: Subdivision: ZEPHYR COMMONS Est. Value: Parcel Number: 35-25-21-0130-0000-0140 Improv. Cost: 1,159.00 OWNER INFORMATION Date Issued: 6/27/2018 Name: SF ZEPHYR COMMONS LP Total Fees: 150.00 Address: 2851 JOHN ST STE 1 Amount Paid: 150.00 MARKHAM, ON. L3R 5R7 CANADA Date Paid: 6/27/2018 Phone: Work Desc: RELOCATE ANNUNCIATOR ADD STROBE-FIRE ALARM-HUMANA -CONTRACTORS APPLICATION FEES COMMERCIAL FIRE&COMMUNICATIONS FIRE ALARM 50.00 FIRE INSPECTION FEES 50.00 FIRE PLAN REVIEW FEES 50.00 FIRE ACCEPTANCE Final Ins ections Refired FIRE ELEVATOR RECALL Chapter 633, Florida Statutes,authorizes the City to charge and collect user fees to pay for the costs of fire prevention and protection related activities such as inspections, plan review,administrative fees,and other costs related to the aforementioned. Complete Plans, Specifications and Fee Must Accompany Application. Commencement of work without written approval of the Fire Department's Fire Marshal or required permits or opening up for commercial activity without an approved final inspection shall be charged double permit fee per day of operation or a minimum of$100.00, whichever is greater. All work shall be performed in accordance with City Codes and Ordinances. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMME MENT " rw- tu� CONTRACTOR SIGNATURE PERMIT OFFICtA PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOURS NOTICE REQUIRED ZEPHYRHILLS FIRE RESCUE DEPT- 813-780-0041 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received 6/18/18 Phone Contact for Permitting 727 530 _ 4521 Owner's Name SF ZEPHYR COMMONS LP Owner Phone Number 813-913-9677 400 CLEMATIS ST STE 201 Owner's Address Owner Phone Number Fee Simple Titleholder Name I N/A Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS 7920 Gall Blvd. Zephyrhills, FL 33541 LOT# SUBDIVISION PARCEL ID# 35-25-21-0130-00000-0140 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED e NEW CONSTR e ADD/ALT = SIGN = = DEMOLISH INSTALL REPAIR PROPOSED USE = SFR Q COMM = OTHER TYPE OF CONSTRUCTION = BLOCK Q FRAME = STEEL = DESCRIPTION OF WORK Relocate annunciator and add ceiling strobe. BUILDING SIZE SQ FOOTAGE 100 HEIGHT =BUILDING $ 1,159.00 VALUATION OF TOTAL CONSTRUCTION =ELECTRICAL $ AMP SERVICE = PROGRESS ENERGY = W.R.E.C. =PLUMBING $ =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION =GAS = ROOFING 0 SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO BUILDER COMPANY SIGNATURE REGISTERED Y/ N FEE CURREA I Y/N Address I License# ELECTRICIAN COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address License# PLUMBER COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address License# MECHANICAL COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address License# OTHER COMPANY Commercial Fire & Communications, In SIGNATURE REGISTERED Y/ N FEE CURREI, L1/N Address 16333 Bay Vista Dr, Clearwater, FL 3773 License# EF20001347 111111111111111111.IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII11111111111111111 RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required.onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster,Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500) •• Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING . (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over_Counter.if nn•public•roodWays:ineeds aOW" NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. a UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work,they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the"contractor Block"of this application for which they will be responsible. If you, as the owner sign as the contractor,that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to'the construction of new buildings,change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due,will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a"certificate of occupancy"or final power release. If the project does not involve a certificate of occupancy or final power release,the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended): If valuation of work is$2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner",I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner"prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction,zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls,Docks,Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone W"unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume"will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction,I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties,the owner may be cited for violating the conditions of the building permit issued under the attached permit application,for lots less than one (1) acre which are elevated by fill,an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate,cancel, alter,or set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans,construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced. An extension may be requested, in writing, from the Building Official fora period not to exceed ninety(90)days and will demonstrate justifiable cause for.the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE Of COMMENCEMENT. FLORIDA JURAT(F.S.117.03) A)1401 OWNER OR AGENT CONTRACTOR Subscribed and sworn to(or affirmed)before me this Subscribed nd sworro or affir ed)before me is by -1 —( by D,,,Z PS C01 M Who is/are personally known to me or has/have produced Who isl re personally known to me or has/have produced as identification. as identification. 1 l� Notary Public Notary Public Commission No. Commission No. 6 'is U 4310 M161PIU. P-ls+31rN Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped MICHELLEALSTON ;=Commission#GG jrU6 Pos Expires October 3o,2o21 °',f`` Bonded Thru Troy Fain Insurance 80D.1R4m�o ,ate' .n O City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: CF(L Date Received: 6 — B top Site: 2—O �� (�b Permit Type: Q 6L( , Cs, Approved Who comments: Approved w/the below comments: ❑ Denied w/the below comments: ❑ This comment sheet shall be kept with the permit and/or plans. Gene Brown—Fire afety Offfcer Date Contractor and/or Homeowner (Required when comments are present) : :ZEPHYRHILLS FIRE DEPARTMENT 38410.6th Ave:Zephyrhills; FL: 33542: FIRE SERVICE'USER FEES increase 1L112018 :Occupancy No.: . Plan'No.: . Contractor: (.�/ -�. . . Business:Name: (1IArt&4.l,- Billing Address: Business Address:. Business Phone No.'. -Billing: . Phone No:: Business fax No,: Billing Fax No.: . ' :Contact:. ` Contact-. . 'PLAN REVIEW FEES: INSPECTION*FEES PERMIT FEE7. - Annual- Ed ucation,healthcare,De tbntion&Correctional Public Assembly,Business, schools, Storage,'Mercantile and Churches , Site Plan, N/C Industrial., 'no charge Sprinkler $50 Multi-Family/Commercial .03 sf up.to 800 s_q ft $ . .24.00 Standpipes $50 (Minimum Charge$24:00 801 -1,500 sq ft ..$ 34.52 Fire Pump $50. Plan Revisions- DBL. 1,501 2,500 sq ft: $. . 60:02: Hoods $50 . 2,501-3.500,sq ft $ 90:02 Fire Alarm $50 SPRINKLER SYSTEMS 3;501=5;000 sq ft: $. :127.52 . LP Gas $50 . �0.-25 Heads. $50 5,501-7,500 sq ft : $. . 187.52 Natural Gas . $50 :26 plus Heads $100 71501-10,000 sq ft $- 262.52 . Fuel Tanks- per tank $50 STANDPIPE SYSTEM 10,001-15,000 sq ft $ 375.02 Sparklers $100 Per Riser $50. 15,00,1-20,000 sq ft- $. .525.02 Fire Works .' $500 • FIRE PUMP 20,001-30;000 sq ft $ 750.02 Camp Fire(recreation: $25 E Per.Pump .$100 30,001-40,000 sq ft ,$.:1,050.02.. Controlled,Burh(15da:. $:100 IRE ALARM.SYSTEM. 40,001'60,000 sq ft $.1,500.02 Hood/Duct $50 -25 Devices: $50 :60,001-80,000 sq ft $ 2,100.02 Place of Assembly $50 Annual 80,001-($2,100,02)per. 26 plus Devices $100 ea add 1,000sq ft $ -0.06 _ Fire Protection . $25. SUPPRESSION SYSTEMS . (Business closed until Flammable Application $50 Annual . - Wet-. $50 violations corrected) Waste Tire Storage $50 Annual Dry $50. SPRINKLER SYSTEMS Generator<KW $100. . CO2 $50 : Hydro.Undergrounds $45 .: Generator>30 KW .-$100 Other. $50 Hydrostatic Test - $65 . per system. Bio-Hazard $100 Annual KITCHEN EXHAUST Acceptance Test $45' per system Fumigation Tenting $50 Hood/Ducts $50 Hydrant Flow $75 Torch Pot/Applied $50 OTHER Haz.Materials $50-: Annual LP Installation pertank $50 FIRE•ALARM SYSTEM Fuel Tank Installation $50 System-Acceptance $50. .(Per Tank) $50 Recall Acceptance $50 EINatural Gas Installation $50 OTHER . ..(Per SyStem), Fire Wall/Smoke Wall: $15. ..:perwalt. El Spray Booth . s50 LP Gas $25 per lank. . Natural per system at ral Gas $25 Tent 10'xl0'or greater $15 per tent Fire Pump. $45 Fire Suppression $30. . System. Acceptance . . . Exhaust Hood/Duct $30 Re-inspection DBL' (other than annual). Inspection scheduled DBL and cancelled less than 24:hours. Construction Insp. N/C cc 0 Emergency Vehicle .A e. $5 PLANS TOTAL INSPECTION TOTAL Y v PERMITTOTAL=. GRAND.TOTAL Comments: Date: ( .. J Inspector:. see back . . . nlh, FALSE,ALARM FEE', ' 1 st Alarm N/C . 2nd Alarm . : : N/C', -3rd Alarm- NIC 4th Alarm. -$100 . '. 5th Alarm' $150 6th Alarm $200. NON.COMPLiANCE $150 Cont.Annual Inspection Fees' 3-11 Units price pet unit $' . : 5.36 , 12725 Units price per unit $ 4:82 26 50Units price per unit'. $. 4.29. 517100 Unit$price per unit $ 3.75 100 or more Units price per unit_ .$ Fire Safety re-inspectionayOes First Re-inspectioi N/C Second reinspect $75'. . : : Third.re=inspectior $' 125.00 Inspection-scheduled but cancelled 24 hrs $ 50.00 LLJ -TOTAL WW�OO �W � s� Wrs t" _� WWAIF Wd C6MMERCIAL FIRE & COMMUNICATIONS Fire Alarms Securiteg./CCTV Fire Sprinklers I, Mark Lediet of Commercial Fire & Communications, Inc. do hereby authorize the following person(s) to act as my agent(s). Please remove all other names. 1. Kelly Williams 3. Darkees Malcolm 2. Edrei Soto 4. Robert Stead X Submit & pick up permits X Make Changes To Permits and Plans X Initial Changes made By the Building Department X Sign Applications for The Qualifier I understand that I am the licensed qualifier responsible for the application as submitted by my agent(s), as referenced above. Thank You for your assistance. As Always, ar Lediet Contractor/Operations Manager Date g EF20001347 STATE OF FLORIDA COUNTY OF PINELLAS Thee regoing instrue t was acknowledged before me this l�4 i day of U"t_ , 20 , by ecUt — who is personally known to me or who has produced a Ktf,� as identification and who di Id no ake an oath. U�I�LI,� S I v' l .� � MICHELLEALSTON Notary Public =Commission#GG 166436 Expires October Fain M�wnaa 800�386.7019 roy Phone:727-530-4521 • Fax:727-531-0596 6510125th Ave.N.Largo,FL 33773 www.cfcsljstems.com Lic#:EF20001347 Commercial FIRE v i v & Communications,Inc. 16333 Bay Vista Dr P.O. Box 1350 Phone(727) 530-4521 Clearwater, FL 33760 Largo, FL 33779-1350 Fax(727) 531-0596 Humana 7920 Gall Blvd Zephyrhills, FL 33541 Fire Alarm System Equipment Submittals Description Manufacturer Part # Strobe System Sensor SCWL Full Service Alarm& Communications Contractor :;: License #EF20001347 I SENSOR ,I Y Indoor Selectable Output strobes and Horn strobes for =- Ceiling Applications S =..,;. System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. Features The System Sensor L-Series offers the most versatile and easy-to-use line of horns,strobes,and horn strobes in the industry • Plug-in design with minimal intrusion into the back box with lower current draws and modern aesthetics.With white and red • Tamper-resistant construction plastic housings,wall and ceiling mounting options,System Sensor • Automatic selection of 12-or 24-volt operation L-Series can meet virtually any application requirement. at 15 and 30 candela The entire L-Series product line of ceiling-mount strobes and horn • Field-selectable candela settings on ceiling units: strobes include a variety of features that increase their application 15,30,75,95, 115,150,and 177 versatility while simplifying installation.All devices feature a plug-in • Horn rated at 88+dBA at 16 volts design with minimal intrusion into the back box,making installations • Rotary switch for horn tone and two volume selections fast and foolproof while virtually eliminating costly and time- consuming ground faults. • Universal mounting plate for ceiling units • Mounting plate shorting spring feature checks wiring continuity To further simplify installation,the L-Series utilizes a universal before device installation mounting plate so installers can mount them to a wide array of back • Electrically Compatible with legacy SpectrAlert and SpectrAlert boxes.With an onboard shorting spring,installers can test wiring Advance devices continuity before the device is installed. • Compatible with MDL3 sync module Installers can also easily adapt devices to a suit a wide range of • Listed for ceiling mounting only application requirements using field-selectable candela settings, automatic selection of 12-or 24-volt operation,and a rotary switch for horn tones with two volume selections. Agency Listings SIGNALING APPROVED LIS1'Ep S5512 FM approved except 7125-1653:0504 S4011 For ALERT modets 7135-16530503 3057383 d L-Series Specifications Specifications General L-Series ceiling-mount strobes and horn strobes shall mount to a standard 4 x 4 x 11h-inch back box,4-inch octagon back box,or double- gang back box.Two-wire products shall also mount to a single-gang 2 x 4 x 17/8-inch back box.A universal mounting plate shall be used for mounting ceiling and wall products.The notification appliance circuit wiring shall terminate at the universal mounting plate.Also,L-Series products,when used with the Sync•Circuit-Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal.12 or 24 volts.When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts;24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Ceiling strobes and horn strobes shall have field-selectable candela settings including 15,30,75,95,115,150,and 177. Strobe The strobe shall be a System Sensor L-Series Model listed to UL 1971 and shall be approved for fire protective service.The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective service.The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal(continuous)pattern.These options are set by a multiple position switch.The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service.The module shall synchronize L-Series strobes at 1 Hz and horns at temporal three.Also,while operating the strobes,the module shall silence the horns on horn strobe models over a single pair of wires.The module shall mount to a 4 11/16 x 4 11/16 x 2 1/8-inch back box.The module shall also control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F(0°C to 49°C) Humidity Range 10 to 93%non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 VDC or regulated 24 DC/FWR' Operating Voltage Rangez 8 to 17.5 V(12 V nominal)or 16 to 33 V(24 V nominal) Operating Voltage Range(MDL3) 8.5 to 17.5V(12 V nominal)or 16.5 to 33 V(24V nominal) Input Terminal Wire Gauge 12 to 18 AWG Ceiling-Mount Dimensions(including lens) 6.8°diameter x 2.5°high(173 mm diameter x 64 mm high) Ceiling-Mount Surface Mount Back Box Skirt Dimensions 6.9°diameter x 3.4"high(175 mm diameter x 86 mm high) (SBBCRL,SBBCWL) Notes: 1.Full Wave Rectified(FWR)voltage is a non-regulated,time-varying power source that is used on some power supply and panel outputs. 2.P,S,PC,and SC products will operate at 12 V nominal only for 15 and 30 cd. AVDS86800 UL Current Draw Data UIL Max.Strobe Current Draw(mA RMS) 8-17.5 Volts 16-33 Volts Candela DC DC FWR 15 87 41 60 30 153 63 86 75 N/A 111 142 95 N/A 134 164 115 N/A 158 191 150 N/A 189 228 177 N/A 226 264 UIL Max.Current Draw(m A RMS),2-Wire Horn Strobe 8-17.5 Volts 16-33 Volts DC Input 15cd 30cd 15cd 30cd 75cd 95cd 115cd 150cd 177cd _ Temporal High 103 167 71 90 143 165 187 217 254 Temporal Low 96 165 54 71 137 161 185 211 249 Non-Temporal High 106 173 71 90 141 165 187 230 273 Non-Temportal Low 95 166 54 71 124 161 170 216 258 3.1 K Temporal High 111 164 69 94 147 163 184 229 257 3.1 K Temporal Low 103 163 54 88 143 155 185 212 252 3.1 K Non-Temporal High 111 172 69 94 144 164 202 229 271 3.1 K Non-Temporal Low 103 169 54 88 131 155 187 217 259 16-33 Volts FWR Input 15cd 30cd 75cd 95cd 115cd 150cd 177cd Temporal High 107 135 179 198 223 254 286 Temporal Low 78 101 151 172 199 229 262 Non-Temporal High 107 135 179 198 223 254 286 Non-Temportal Low 78 101 151 172 199 229 262 3.1 K Temporal High 108 135 179 200 225 255 289 3.1 K Temporal Low 79 101 150 171 196 229 260 3.1 K Non-Temporal High 108 135 179 200 225 255 289 3.1 K Non-Temporal Low 79 101 150 171 196 229 260 Horn Strobe Tones and Sound Output Data StrobeHorn and Horn Output 8-17.5 16-33 Volts Volts Switch Position Sound Pattern dB DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89. 89 8 3.1 KHz Non-Temporal Low 77 83 83 AVDS86800 S L-Series Dimensions 2.47 6.83 1.37 06.92 2.50 �Morr�t� O 8TRR O O cm 0 0, O O ® O O O o Q o 0 Ceiling-Mount Horn Strobes Ceiling Surface Mount Back Box m , ��a►l1rt ® m ° 0 0 m �Do °oo Ceiling Mount Horn Strobes with Ceiling Surface Mount Back Box L-Series Ordering Information Model Ceiling Horn Strobes Ceiling Strobes PC2RL 2-Wire,Horn Strobe,Red SCRL Strobe,Red PC2WL 2-Wire,Horn Strobe,White SCWL Strobe,White SCWL-CLR-ALERT Strobe,White,ALERT Accessories TRC-2 Universal Ceiling Trim Ring Red TRC-2W Universal Ceiling Trim Ring White SBBCRL Ceiling Surface Mount Back Box,Red SBBCWL Ceiling Surface Mount Back Box,White ����m ©2017 System Sensor. 3825 Ohio Avenue•St.Charles, IL 60174 Product specifications subject to change without notice.Visit systemsensorcom SEN�®�a Phone:800-SENSOR2 Fax:630 377-6495 fO O l product intomauon.including helatest version otthis data sheet. AVDS86801•03l17 (NFPA 72,2002 Edition) - 1 - Fire Alarm System Record of Completion Protected Property: Rep. (Name/Phone) Address: Authority Having Jurisdiction: ^ ' Address/Phone No.: ' _ Organization Name/Phoney Representative Name/Phone Installer: Supplier: (� f^' Service Org. C C. ; �, ...1 r;'.{' !'. ( r: . :(' / ;'r 1 1^i FL l t ),� (" i /.'cJ t. Location of Record(as-built)Drawings: <- Location of Owners Manual: Test Reports: A contract for test and inspection in accordance with NFPA standard(s): Effective Date: Expiration Date: System Software: a) Operating System Software Revision Level(s): b) Site Specific Software Revision Date: c) Revision Completed by: (Name) (Firm) 1. Type(s) of System or Service: NFPA 72, Chapter 6—Local If_alarm is transmitted to location(s) off premise, list where received: 4 ' NFPA 72, Chapter 8 -Remote Station: Account Telephone Numbers Of Organization Receiving Signals: If alarms are re-transmitted to public fire service communications center or others, indicate location and telephone of the.organization receiving alarm: Indicate how alarm is retransmitted: NFPA 72 Chapter 8—Proprietary: Account#: Telephone Numbers Of Organization Receiving Signals: If alarms are re-transmitted to public fire service communications center or others, indicate location and telephone of the organization receiving alarm: Indicate how alarm is retransmitted: NFPA 72, Chapter 8 -Central Station:` Account#: The Prime Contractor: Central Station Location: Means of transmission of signals from the protected premise to the central station: McCulloh Multiplex One-Way Radio Digital Alarm Communicator Two-Way Radio Others Means of transmission of alarms to the public service communications center: (a) (b) System Location: 2. Record of System Installation (Fill out after installation is complete and wiring checked for opens, ground faults, and improper branching, but prior to conducting operational acceptance tests). This system has been installed in accordance with the NFPA standards as listed below,was inspected by on 417;' " ' , includes the devices noted below and has been in service since NFPA 72, Chapters.:I ,2 3 ;4` 5 6 7 8 A.0 11 (circle all that apply) -2- NFPA 70,National Electrical Code,Article 760 'k Manufacturer's instructions Other(specify): Signed: — -Date: Org.: f C- ' i 3. Record of System Operation Documentation in accordance with Inspection Testing Form,Figure 10.6.2.3 is attached: All operational features and functions of this system were tested by (_t- on ( %. ` I' ; and found to be__operating properly in accordance with the requirements of: NFPA 72, Chapters :1,_ 2 34' S ;6 -.7, 8 10 11 (circle all that apply) NFPA 70,National Electrical Code,Article 760 Manufacturer's Instructions Other(specify): Signed: - Date: ' f ;..} `/ Org: (Chapters: I—Admin., 2—Referenced Pubs, 3—Definitions, 4-Fundamentals, 5—Initiating Devices, 6—Protected Premises, 7—Notification Appliances, 8—Supervising Station, 10—Inspecting& Testing, 11—Household Alarms) 4. Signaling Line Circuits: Quantity and Class (See NFPA 72, Table 6.6.1) of signaling line circuits connected to system Quantity: Style: Class: 5. Alarm Initiating Devices and Circuits(Use blanks to indicate quantity of devices) Quantity and Class of Initiating Device Circuits(NFPA 72 Table 6.5): Quantity: Style: Class: MANUAL a) Manual Stations: Noncoded Addressable: Transmitters: b) Combination Manual Fire Alarm and Guard's Tour Coded Stations: AUTOMATIC Coverage: Complete: Partial: Selective: Non-Required: a) Smoke Detectors: Ion: Photo: Addressable: b) Duct Detectors: Ion: Photo: Addressable: c) Heat Detectors: FT: RR: FT/RR: Addressable: d) Sprinkler Water Flow Switches:Noncoded,: Transmitters: Addressable: e) Other(list): 6. Supervisory Signal Initiating Devices and Circuits(Use blanks to indicate quantity of devices) SPRINKLER SYSTEM ENGINE DRIVEN FIRE PUMP a) Valve Supervisory Switches h) Selector in Auto Position b) Building Temperature Points k) Selector in Auto Position c) Site Water Temperature Points i) Engine or Control Panel Trouble d) Site Water Supply level Points D Fire Pump Running ELECTRIC FIRE PUMP ENGINE DRIVEN GENERATOR e) Fire Pump Power 1) Control Panel Trouble f) Fire Pump Running m) Transfer Switches g) Phase Reversal n) Engine Running Other Supervisory Function(s)(specify): 7. Annunciator(s): Qty: 1 Type: Location: 8. Alarm Notification Appliances and Circuits: For Emergency Voice/Alarm Service: Quantity of voice/alarm channels: Single: Multiple: -3- v Quantity of speakers installed: Quantity of speaker zones: Quantity of telephone or telephone jacks included in system: Quantity and Class of Notification Appliance Circuits connected to the system: Quantity: Style: Class: Types and quantities of notification appliances installed: a) Bells: With Visible: b) Speakers: With Visible: c) Horns: With Visible: d) Chimes: With Visible: e) Other: With Visible: f) Visible Appliances without Audible: 8. System Power Supplies: a)Fire Alarm Control Panel:Nominal Voltage: Current Rating: Overcurrent Protection: T e:� 't yp Current Rating: a- Location` _> b) Secondary(stand-by) Storage Battery Amp-Hour Rating: Calculated capacity to drive system, in hours: Engine driven generator dedicated to fire alarm system: Location of fuel storage: c) Emergency or Stand-by system used as backup to Primary Power Supply: Emergency System described in NFPA 70,Article 700: 10. Comments: ( Frequency of routine tests and inspections, if other than in accordance with the NFPA standard(s): System Deviations from the referenced NFPA standard(s)are: (signed)Representative of the Installation/Supplier Company (title) (date) (signed)Representative of the Alarm Service Company (title) (date) (signed)Representative of the Authority Having Jurisdiction (title) (date)