Loading...
HomeMy WebLinkAbout18-19718 y CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 19718 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL PERMIT INFORMATION LOCATION INFORMATION Permit#:19718 Issued: 6/06/2018 Address: 38654 9TH AVE Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 242,986.05 Total Fees: 2,431.28 Subdivision: CITY OF ZEPHYRHILLS Amount Paid: 2,431.28 Date Paid: 6/06/2018 Parcel Number: 11-26-21-0010-10500-0011 CONTRACTOR INFORMATION OWNER INFORMATION Name: CUSTOM HOMES LLC Name: PETBER LLC Addr: 6084 IDLE A WHILE CIRCLE Address: PO BOX 566 RIDGE MANOR, FL. 33523 ZEPHYRHILLS FL 33539-0566 Phone: Lic: Phone: 813-992-0996 Work Desc: CONSTRUCT SINGLE FAMILY 2,157 SQ FT APPLICATION FEES BUILDING FEE 1,355.09 ELECTRICAL FEE 282.38 PLUMBING FEE 188.25 MECHANICAL FEE 131.78 WATER METER RES 3/4" 473.78 kww 41- - SI, Inspections Required FO TER 2ND ROUGH PLUMB Misc INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRACTORS SIGNATURE PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER Q �r -I:I:UUIUH• - J� �//•/iS�• City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: Date Received: 2_C Site: S � 3-7 �J J Permit Type: l a Approved Who comments:❑ Approved w/the below comments: Denied w/the below comments: ❑ This comment sheet shall be kept with the permit and/or plans. 00, Kalvin wi r— ans Examiner Date Contractor and/or Homeowner (Required when comments are prk, Custom Homes-38654 9th Ave 2,157 sq ft-credit due on this home was address 5637 13th st Column Es SQ. FEET PRICE MAIN OR LIVING: 2,157 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 242,986.05 FEE SHEET $ 1,255.00 ADDRESS $ .30.00 DRIVEWAY1 $ 45.00 BUILDING: $ 1,355.10 ELECTRICAL: $ 282.38 PLUMBING: $ 188.25 MECHANICAL: $ 131.78 SUB-TOTAL $ 1,957.50 TOTAL $ 1,957.50 SEWER: n/a WATER: n/a IRRIGATION: $ - TOTAL: $ - WATER METER:1 $ 473.78 IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE FIRE 5% $ - TOTAL: credit due SUB-TOTAL $ 2,431.28 PARK IMPACT FEES credit due SIF'S: 100.0% $ - 1.0% $ - TOTAL: $ - credit due T I F'S: credit due 99% $ - 1% $ - TOTAL: $ 2,431.28 u1s-1au-uuzu Ulty OT Gepnyrniiis vermlt Application Building Department Date Received =.Phone'Contact for Permitting ��✓ /�� —'"��� Owner's Name G Owner Phone Number , a f� 0M, Owner's Address •(�' !7 �v Owner Phone Number Fee SimplelTitleholder Name Owner'Phone.Number Fee Simplelitieholder A ress JOB ADDRESS �© S7 ��'/ U LOT# SUBDIVISION PARCEL•ID#. ��������'O �' d���`'�v v (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NSTR ADD/ALT 0' SIGN = = DEMOLISH INSTALL e REPAIR PROPOSED;USE = SFR Q : Comm = OTHER TYPE°'OF CONSTRUCTION BLOCK 0. F ME STEEL 0 rI J DESCRIPTION'OF WORK' �/ ^I'l c 1 J / - rIPyY s BUILDING"SIZE SQ FOOTAG :HEIGHT•• =BUILDING $ / zS ,4rV VALUATION'OF TOTAL CONSTRUCTION =ELECTRICAL $ [ vw AMP SERVICE = PROGRESS ENERGY Q W.R.E.C. =PLUMBING $ 7 =MECHANICAL $ /� VALUATION OF MECHANICAL INSTALLATION 1 �V =GAS = ROOFING. 0 SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO i ,BUILDER COMPANY C� SIGNATURE REGISTERED Y/ N " FEE CURREN L Y/'N Address 'L-icense:# 1 ELECTRICIAN. J COMPANY' SIGNATURE REGISTERED I JY/ N ,' FEE�CURREN , " Y IN p Address' License# PLUMBER,; 'COMPANY: : �«f -SIGNATURE ' REGISTERED Y7"N•. ' . " 'FEECURR& Address �� W� Li J� '//�' ✓��e License MECHANICAL' SIGNATURE'' REGISTERED Y/-N FEE:CURREN Y/N Address License.# ..c7mC/�`�/��S'� OTHER ;:: COMPANY -SIGNATUREY REGISTERED Y/..N FEE-Cl1RREN Y/N Address:, License `�.iRESIDENTIAI.:�=�Attach;�2�PlotsPians}`2=sefs'•ofBiildiri"Plaris• 1Jset of�Ene 'Forms•R=O=W Permit^`r oew.constiuction ry,.;N,_.:. F Minimum teri 10,:workin a after'_sutirFiittal<date. Re uired'onsite'GonstN'ction'PI"ns'Sformwater Pia`s w Silt installed,ence _ ::_�-i:.:�x..,:4.- -,,: .. ,.���.P>(+.....):_,:,..._.,,g�•d.Ys. .. q P a n / F �� Sanitary�F,acilities���l�,dumpster;Sfe;Work_:,Permit:for�subdivisions/large�proJeets.=.:' -'- . .:.�- .:COMMERCIAL Attach'°t2)complete sets'of'Building Plans plus a l:Ife Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction: <: Minimum ten(10)working days after submittal date. Required onsite,Canstruction Plans,Stormwater Plans w/Silt Fence installed, . '`" Sancta Facilities Z£1 dum ster Slte Work Permit fog all-neuu ro ects.All commercial re uirements must meet compliant® :+SI,GNPERMIT Attach-O'sets::ofEngiiieered flans: "'•PROPERTY SURVEY,required for,all,NEW,„construction:.; rectiOnB:' s? -ill'ouI application completely. O.wnerA Contractor:sign.back of application,notarized If over$2500i,a Notiro:of:Commencement.is required. (AIC upgrades over$7500) ]4 ent'1o��tlie`coritractor°or°Power.'of Attome" fdr'the owner would lie someone with notarized letter from owner authorizing same g � � ) Y( ) 9 0vittuTHE 000NTER�P_ERM,ITJIPIG; (copy..of contract<required. :'Reroofs if ngles Sewers. Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways.Adeds`ROW` NOTICE'W DEED-RESTRICTIONS: :The.undersigned understandsakiat:;this,.peemit;may:be subject.to.:"deed"„restnctldns".;'.; . which:may be;rriore.restrictive=*.tflan;County.regulations: Therundersigned`assumes res 9)9ibi,46'r compliance with'any - applica-ble.ileed restrictions. `; UNLICENSEM-CONTRACTQRS ANCt"CO.NTI2ACTOR RESPONS1131LtTaES '`if=tE a owner, , as`Jiltb l°a':contractor-;or- .:._. contractors to undertake work;they i. maybe-reqU'Ired,.'fo be=,licensed in accordance with:-state and'lacai cegulaiians,=r If th'e=:-`- contractor.."is-riot:licensed'asrequired"py.law; both the avi►ner-and'-contraetor-msay4beFccited fora=iisdei}isanar-violation under state'Ww if the owner.or.:.intended�contractor are uncertain as.to what:licensing:requireinet fis imayxapply:for intended work-1hey:are advisedto contact the"Pascd-CountyBUiidin- W"' ection.Division Licensing,Section at 727=847- 8009: Furthermore, .if the owner has"°hired`a contractor or contractors, he Yis advised td: have the:;contractor(s):,sign ,..:. lr...a portions of the "contractor of this application.for whichthey..will.be.:responsible :lf,you,°.a ihie'd rrner"sigrr as-ttie '`=T; contractor, that may be an indiiJation that he-1 properly`licensed and is not entitled to permitting prJviteges in i?asca County. TRANSPORTATION,IMPACTIUTIL•ITIES:IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands : that Transportation Impact Fees and Recourse Recovery Fees°.may.-apply. Wthe construction of..new,buildings,._chan`ge�of`.;,= use In existing,buildings,,or.6xodnsion.of'<exlstin*d-buildings, as specified in Pasco County Ordinance number 89 07 and 90-07, as amended. The-undersigned=also understands;.:that suchcfees, as may be,due, will,'4 identifiedilat.th-ii' permitting. =1t is-further understood that Transportation'iinpact-Fees,-and Resourca;Re%overy.Fees•must be paid,priar`to receiving.a_"certificate_of occupancy"or final power,release: °If the:projeet does not 1nvoIve'a certificate of accupan'cytioc= final power release the:=fees.rnust be:.paid prior,to..permit issuance.._,;Furthermore,-if-Pasco County Water/S,ewer-ampa_ct:-s-r fees are-due;.-they.must.be,,paid prior to 7permit•issuance in accordance With,applicable.�Pasco'County ordinances. CONSTROdTlib LIEN LA{M-(Chapter 711;Florida Statutes, as amended): if valuation of work is$2,50;OAO.,or:tn.ore;1:, certify that 1, the applicant, have been-provided with a .copy....olAhe "Fiarida--Construction'-Lien ;Laves-Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer:Affairs. If the applicant'is.:someone other than the"owner",1 certify that.l..have obtainetl a copy of the above'descn ed`document and promise=in.good`falth to:..,. deliver.it,to'tlae:".owner!':pribr:.fo.conimencement CONTRACTOR'S%OWNER'S AFFIDAVIT:,.;1;,certify;that•all the information in this application is accurate and`that alf work will be done in compliance with all applicable`laws regulating construction, zoning-and land.development. Application,.is hereby.made to:.obtain:a; perrhit,,.to:-do work and installation .as`indicated. 'I certify that no work or•:installati'` as commenced prior to issuance of'a permit and--that all work will be performed to.meet;standards--of all laws regulating construction, County and City codes, zoning regulations, and land development regulations-in-.the jurisdiction. I:'also certify that I understand that the regulations of other government agencies may apply to the intended work, and that It is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not llimitedjo.t - Department of EnvirorimentaiF,`Pratectioh-Cypress Bayheads; Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. t - Southwest Florida Water Management District-Wells, Cypress -Bayheads, Wetland Areas, Altering Watercourses., Army Carps of Engineers=Seawalls, Docks;'Navigable Waterways. - Department .of Health,,&,Rehabilitative. Services/Environmental.,.Health :Unit Wells,:Wastewater:Treatment, Septic°Tanks.: .. : - US-Environmental Protection Agency-Asbestos.abatement. - Federal-Aviation-Authority Runways., I understand that.t11,6:following`;restrictions apply to the use of fill: Use of fill is not:allowed in Flood Zone"V"unless expressly permitted. if the fill:-matel al;I` to be used in- Flood Zone " , it is understood that a-drainage plan addressing a "compensating volume"will be submittedA"at time of permitting which is prepared by a professional engineer licensed bythe,;State�of Florida, If the fill material is to be used in Flood Zone "A" in connection with a permitted-building using stem wall construction, I certify:that fill will be used only to fill the area within the�stem wall. If fill. material Is-to be used in'.any area, I certify that use of such-fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties, the owner may be cited for violating the conditions:of the`bubiding,permit,issued under the attached,permit,application,....for.,,IotsJess than one (1) acre which are elevated by fill, an engineered drainage plan is required. If I am the AGENT;FOR THE.OWNER;.,;promise in,good faith to inform,the owner.of-the permitting-conditions set forth in this affidavit priorto commencing'constriictiori. '(:understand that.a,,separate permit may be required,for electrical.work,, plumbing, signs, wells,.pools, air.conddltloning,<gas;.or•oth6i i'I s'tallations not specifically included in the application. permit issued shall°be:construed=to tie a'l cense'to.proceed,with't -a work and not<-s authority-to violate;.cancel, alters or set aside any provisions of`the­technical codes, nor shall issuance of a permit prevent the Building Official from thereafter a, requiring a correction ofsrrors-in:plans;construction.orviolations of any�codes. Every permit issued'shali'become invalid unless the work authorized biy such permit is commenced.within six,months of permit issuance, or if work authorized!by- the permit is•suspended:or abandoned,for six(6)rnonths.after the time the work is commenced. An extension may be requested, in writing,.from.the Building`Official for a period.not to exceed ninety t90)-days and will demonstrate justifiable cause for.the extension. If work-ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING -O`OWNER;.` YOUR..FAII uR':TO.,RECORD:A NOTICE,OF C-,MMENCEMENT•MA RESULT IN YOUR '. PAYING TWICE !lNlPt20VEMENTS;TO.YQUR PRQPERTY::.IF YOU INTEND=TO�OBTAIN fINANCiNG,:CONSULT —WITH-YO UR'LkN`DER-ARAN ATTORNEY BEFORE-RECORDING YOUR'NOTICE'OFI_COMMENCEM&r : FLORIDA JURAT(F.S.1.17.03) OWNER OR AGENT CONTRACTO Subscribed and-sworn to(or affirmed).before me this Subscribed and sworn to(or afBrtned),before me this by by Who Is/are personally known to me or has/have produced Who Is/are personally,knowri to me or has/have produced as ldendficaUon. as identification. Notary Public Notary Public . Commission No. Commission No. Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped Custom Homes-38654 9th Ave 2,157 sq ft-credit due on this home was address 5637 13th st Column Es SQ. FEET PRICE MAIN OR LIVING: 2,157 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 242,986.05 FEE SHEET $ 1,255.00 ADDRESS $ 30.00 DRIVEWAY $ 45.00 BUILDING: $ 1,355.10 ELECTRICAL: $ 282.38 PLUMBING: $ 188.25 MECHANICAL: $ 131.78 SUB-TOTAL $ 1,957.50 TOTAL $ 1,957.50 SEWER: n/a WATER: n/a IRRIGATION: $ - TOTAL: $ - WATER METER: $ 473.78 IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ PUBLIC SAFETY IMPACT FEES POLICE FIRE 5% $ - TOTAL: credit due SUB-TOTAL $ 2,431.28 PARK IMPACT FEES credit due SIF'S: 100.0% $ - 1.0% $ TOTAL: $ - credit due T I F'S : credit due 99% $ - 1% $ - TOTAL: $ 2,431.28 Custom Homes-5637 13th St-2,157 sqft Column Es SO..FEET PRICE MAIN OR LIVING: 2,157 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 242,986.05 FEE SHEET $ 1,255.00 ADDRESS $ 40.00 DRIVEWAY $ 40.00 BUILDING: $ 1,360.10 ELECTRICAL: $ 282.38 PLUMBING: $ 188.25 MECHANICAL: $ 131.78 SUB-TOTAL $ 1,962.50 TOTAL $ 1,962.50 SEWER: n/a WATER: n/a IRRIGATION: $ - TOTAL: $ - WATER METER: $ 473.78 IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE Credit FIRE Credit 5% $ - TOTAL: $ - SUB-TOTAL $ 2,436.28 PARK IMPACT FEESI Credit SIF'S: Credit 100.0% $ - 1.0% $ - TOTAL: $ - T I F'S: Credit 99% $ - 1% $ - TOTAL: $ 2,436.28 Building Department ¢ n Date Received � ,Z-/6 Phone Contact'for Perrnittin �/�3 1/ -^��b 9" Owner's Name G Owner Phone Number Owner's Address lJ' 19 Owner Phone Number Fee SlmplaJittehotder Name Owner Phone Number Fee Simple:Titleholder Address /q JOB ADDRESS LOT{f SUBDIVIS16N PARCELID# ��{a" I-G7 .� �• d ©p U (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED ..NEW CONSTR'= ADD'/ALT SIGN = Q DEMOLISH INSTALL 'REPAIR PROP..OSED,USE 0 SFR = COMM 0 OTHER TYPE`OF CONSTRUCTION EK BLOCK Q FIR IAME STEEL 0 j c�I'� DESCRIPTION'OF WORK �Y y 1�T c- r /("� / ---T -BUILDING.i;IZE LI�LI t'� j SQ FOOTAG =BUILDING $ /z� VALUATION OF TOTAL CONSTRUCTION =ELECTRICAL, //Jr �9��I AMP SERVICE Q PROGRESS ENERGY C] W.R.E.C. � J =PLUMBING $ r/Sv =MECHANICAL $ �GG--+7�+!r? VALUATION OF MECHANICAL INSTALLATION =GAS Q ROOFING 0 SPECIALTY = OTHER r FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA .=YES NO Hill BUILDER t �'�/2 REGIMST D G Y FEE RREN YlN. PANY SIGNATURE Address 'Licensee ELECTFtIt:tAN COMPANY G1...r �(rGCf/G SIGNATURE 7 /��� REGISTERED I Y/ N FEE'CURREN Address lrZ ` ' G / GC! C' License# P"LUMBER. ,'„ .-. C051PANY. C �Pf' (till/ SIGNATURE rr�� Q -REGISTERED Y/'N. ' FEE CU Y t N Address i tv JT '/// a� License#. Fe 1q,1$/ `� : -MECHAh[16A ' .,COMPANY. ..,5d!/l.(`y�i✓CG� Hof SIGNATURE;+'' ".. .. REGISTERED ..,I •Y/ N FEE:CURPFJN,, 'Y/N. Address,. •� r/'",�''D�' C"Y'''�'dr /nrE' mil" < <- License.#.��G��j`Fi�3�S/�1�... COMPANY OTHER= C SiGNAT17FtE REGis7EREo ,.Y/.N FEE CU[RRE�N YIN Address,; License# >. :RESIDENTIAL";r Attach r2);Plot P,lens>'(2)sets:of9trllding Plans;(1)'set of Eneigy:Forins;R 0-V1!Perinitfor new.constiuc0on;, . �.Minlmumrten 10 warkin"da pafte'rsiibmittal:date :R r (•."),, 0}' Y`. equired'orisite;Construction Pians,'Stormwaterplans w/Silt Fence installed, Sanitary Facilities; i:duJnpster_Si(a;.Works?ertnit:f6r'stitbdivlstonsRarge'prpJests` . `.:. -. :GOMMERCiAL Attach'(2j'compieteisets aFSuiidl g Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit far new construction: Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence Installed,. Sanitary Facilities&j dumpster.Site Work Permit foi ll,newpiojects.All commercial requirements must meet compliance SiGN,.PERMIT AtCaclr'{2)`sets,0-E6giri@eyed ****PROPERTY SURVEY required for-aII,NEWconstructlon.. Ditecyons: All out application completely. Owne,, ,Contractor,sign back of application,notarized 'If over$2500;--a NbUce.of:Commencement is required. (A/C upgrades over$7500) Agent:(forthe contractor)or Power cfRftomey{for the owner}would do someone with notarized letter from owner authorizing same r;iOtVt R.THE COUNTER,PERN1iTTIP(G. :. ..(oopy.of contract-required) ;•`Reroofs if'sfiingles Sewers. Service Upgrades A/C Fences{Plot/Survey/Footage} Driveways-Not over Counter if on public"roadways::needs ROW Single Family Dwelling. Plan Review Comments 1: F.F.E. shall be a minimum of.8" above.the road elevation and an engineered site plan. 2.. Lots shall be graded to comply with R401.3 of the F.R.C. 3. Compaction test required if 24" or more of-fill dirt is brought in at any one place: 4: 'Tie in survey required before pouring concrete. 5. Driveways require a R.-O.W. use permit. All 4 sides of driveway thru the sidewalk shall have expansion material: 6. All setbacks.shall be met: . 7. All property:markers shall be.uncovered and marked at time of first inspection: 8. All A.D.A. requirements shall be met. 9. No electric, plumbing, mechanical, or framing shall be covered without an:inspection and approval first. 10. All Garages shall comply with-section R302.6 of the.F.B.0 (Fire S:eparatio.4, 11. Appliances shall not.be installed in a location where subject'to,mechanical damage unless protected by.approved barriers. M303.4-of the F.B:C 12. Water heaters shall comply:with section P607.3'of the F.B.C. 13. Foundation supports-for-A/C.units shall be raised at least 3'.' above finished grade. M1308.1 14. Return airin all-bedrooms..F.B.C. M1620.4 15. Smoke detectors are to b-e installed in accordance with R313.1 of the F.B.C. 16: All glazing requirements are to be in accordance with R308.4.of the F.B.C. 17. All means of egress are to be in accordance with R311 of the KB.C. .: 18. "Green gypsum.board''shall not be used: a backer.in showers or tubs. R702.4:2 F.B.C. 19. Combination-type AFCI breakers are required at all.locations requiring an AFCI type breaker. 20. Carbon monoxide alarms will be required in-new:construction that uses fossil-burning heating or appliances or an attached garage. They shall be installed in accordance with the F.B.C. 21. All plumbing, mechanical, and:electricai shall be separate from unit,to.unit: This includes all ;underground plumbing and electric: 22. A112011.N:E:C: Codes will be enforced: 23. Tamper-Resistant Receptacles in accordance with 406.11 of the 2011 N:E.0 24: In accordancemith_the Land Development Code; lots shall be sodded before final at least 10 feet_around the structure. 25. A.copy of the eizei:6 cacls shall be with pe.rmitat all dines. 26 Com of rtnal insulation'report shall be provided with.Permit before.fnaL RE E.-Finished Floor Elevation F.B.C- Florida Building Code 6 h Edition R.O.W.-Right of Way A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2011) I11111fIIllIIIIIIIIIII111111111111111IIIIIIIIIIIIIIIIIIIIIII /-2018084261 Permit No. Parcel ID No —or7�O—/pS72Cr_00 J NOTICE OF COMMENCEMENT r State of �L�r/old County of THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 713,Florida Statutes, the following information Is provided in this Notice of Commencement: 1. Description of Property: Parcel Identification No. Street Address: ✓G s� /,P �� `/ C sG 2 2. General Description of Improvement r 3. Owner Information or Lessee information if the Lessee contracted for the improvement C Address Ctt ' _ State Interest in Property: y- Name of Fee Simple Titleholder. (If different from Owner listed above) w Address (�•► City State A. Contractor. 01jiCs N ` -(1/ �c C ,,& Ai ,3.YJ2-3 Address c�. f7 n city, State od�� Contractor s Telephone No.:cZ�✓ �/ J LlJ e: w 5. Surely: L)' d Name 0 N E Address City State a N~ Amount of Bond: S Telephone No.: C; L �N 6. Lender. a.-y Name z�v, Address City State o N]C Lender's Telephone No.: "' c0 7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by Cr� G Section 713.13(1)(a)(7),Florida Statutes: a B Name Address City Slate Telephone Number of Designated Person: 8. In addition to himself,the owner designates of x to receive a copy of the Lienor's Notice as provided in Section 713.13(1)(b),Florida Statutes. Telephone Number of Person or Entity Designated by Owner. v 9. Expiration date of Notice of Commencement(the expiration date may not be before the completion of construction and final payment to the a contractor,but will be one year from the date of recording unless a different date Is specified): WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT RIIDRDANGPTCEYOEMNTST PPRTnN CMENEMSRESULTNYOUPYIWIFRMPRVEOYOUROPER . ANOTIC� O FLORIDA STATUTES MUST 0 t9]G LT WITH YOUR LENDER R AN ATTORNEY BEFORE COMMENPOSTED ON THE JOB SITE BEFORE THE CING WST ORK OR RECORDIN YOUG YOUR NOTIOBTAIN E F COMMENCEM CONSU IENT. 01 •• O Under penalty of perjury,I declare that I have read the foregoing notice of commencement and that stated therein are true to the best of my knowledge and belief. N Y S. t,ORh�ABATHA.N WRIGHT c eiF Sc c�o �4 MY COMMISSION#GG114046 Signature of Owner or Lessee,or Owner's or Lessee's Authorized In m N =?; EXPIRES July 04.2021 OfficerlOuectorlPartnerlMenager Go ..X r+ Signatory's Tille/Of ice a••t / W-G m The foregoing instrument was acknowledged before a this I L day of 20 0by ✓`�" r ` r�G as ' A-7,a C br/ (type of authority,e.g.,officer,trustee,attorney in fact)for bl°r (name of party� om* en wa executed). PersonatiyKnown[]PA Produced Idontiftcationi/^� Notary Signature / Type of identification Produced �L �J L Name(Print) "y �� � • ° �'�,® STAT5 OP FLORIDA, COUNTY OF PASCO THIS IS T0'CERTIFY THAT THE FOREGOING IS A TRUE AND CORRECT COPY OF THE DOCUMENT *ya ON FILE OR OF PUBLIC RECORD IN THIS OFFICE WITNESS MY HAND A D OFFICIAL SEAL THIS r DAY OF OQ 2G/� • Ito, s PA LA S. O'NEIL, CLERK COMPTROLLER m ® ®�®®� BY DEPUTY CLERK PERMIT APPLICATION DRIVEWAY PERMIT APPLICATIO14 CONSTRUCTION WITHIN PUBLIC RIGHT-OFW�WAY All Information MIgA be filled-in completely City of Zephyrhills 5335 am Street, Zephyrhills, FL 33542 Telephone 813.780.0000 Fax$13.780.0005 �te:i�f�ppilcatlr' ��_ ' �reree��t��•8yt � ��.� " '•15: . . . .I�ermlt"#: . ., Ccrsr.na sorsun m�i�ih9 _ ;ft opy,taBul{�ing'U�p?rim�nt l a Y W PUM.Wvrji . 5- 'PROJECT/JOB � SITE: PROPERTY-OWNER Address: UC, _Name: Unit : Address: o•fJcrr s', x- Unit: Parcel Identification Number:/= �2/voiv-ros�r�o�i Glt State,Zip 2e iAie Phone: P/ " 99.E p . d Fax: CONTRACTOR: - Company: e - Name; Contractor's Ucense #: C �cos.�z; 6 _E-Mail: z5;K.-.vp ...5 y .�_ ,f:�w� i2;co•� Phone: Cell: P13 9/32Pgp Fax. — - ARCHITECT/ENGINEER: Name: Firm Name: _ Address: Cityl State: Zip: State License #: Phone: Cell: Fax: Descrintlon_of EMIg t �IbRIVEWAY -P �:i1�.VMn LENGTH OF DRIVEWAY NEEDAD IDENTIAL DRIVEWAY &I'LWIDTN OF DRIVEWAY { }REINFORCED CONCRETE COMMERCIAL DRIVEWAY R.Q.W. EXCAVATION ( ) CORRUGATED MATERIAL PUBLIC ACCESS DRIVEWAY DEPTH !!NEAR FEET [ }BOX CULVERT CONSTRUCTION MATERIAL CURB CUB'REQUIRED ( )OTHER(EXPLAIN) _ASPHALT YES ,�ENO }-CONCRETE HFAUNALL RLQUIRED? YES NO NOTICE T APELIGANT.- If actual work exceeds scope of this description, additional permits or drawings will be required. UTILf3jLQQUIONSREQWBf& CALL BEFORE YOU DIG: 1.800.432.4770 Page 1 of 3 PiilffililT APPLICATION UTILITIES LddATE CONFIRMATION NUMBER:--------------------- PROVIDE SKETCH IN THIS AREA, IF ADDITIONAL SPACE IS REQUIRED, ATTACH TO THIS APPLICATION. AFFIDAVIT: Application is hereby made to obtain a permit to do work and installations as indicated. I certify that all foregoing Information is accurate and that all work will comply with all applicable codes. I understand these codes shall take precedence over all approved construction documents,and issuance of this permit is verification that I will notify the property owner of Florida Lien Law req., F.S. 713. The Issuance of this permit does not ensure compliance with deed restrictions and i understand that additional deed restrictions may apply to this property. All work shall comply with the current Florida Building Code,Public Works Design Manual and FDOT Design Standards (if applicable). (Public Works Design Manual online link: wwwA.zephyrhilis.fLusfpublic—works.asp) APPLICATION IS VOID UNLESS SIGNED WITH PROPER IDENTIFICATION AND WITNESSED BY A PERMIT TECHNICIAN OR NOTARY PUBLIC. NOTE: The City of Zophyrhilis is not responsible for maintenance or repairs of driveways. Driveways shall not alter 1 Interfere with existing stormwater treatment and/ or conveyance. PROPERTY OWNERS: By signing this application: I certify that I have read and understand the owner/builder disclosure statement._ (please Initial) Applicant Print Name Applicant Signature Permit Technician Signature (or) Notary Signature Date Applicant Is( personally known to me or produced as Identification. (type of identification) Page 2 of 3 'i� � J,.�4FA.� .y..y 1..h„+ _ ++Mrs'.++ .��R "�i-..rr.r+.N •- ' � Pr � a i� }'may.. � y � •y RAJ', AC �• • • - + ;�h ' • k _ 1 ..AAS'CO-t�J.:NTY..3"iL4RfpA.. PERMIT APPLICATION OFFICE USE ONLY - PfJBL1C ' t SE-Q.uL: Concrete :(min. 6°} Y . N - Asp Y _ - — A _-.- - Asphalt(min. 134"} Y N Length (min. 19:) Y )N Width (10' min--20'max) Y N Existing,sidewalk._ Y N New sidewalk. Y N ADA compliant. Y N .Expansion material required. Y" l4. -- iS Contiguous parking pad._- Y Triangular flare (3'W x 71 Y N Visibility triangle o.k.? Y N Side set back (3' min. R.O.W:) Plan Review Fee ! Additional deacri lion of.work as_defined.bi Pubi#c.tflor�s_Director and or_dmi rvew- 00 agn Permit application approved by: lVl Page 3 of 3 , Aa/of�ess siS,3� /�nY ,�j t i Q t�( x(Ai ' OF WAY, _ 4 Z�V� ce ygilosloo WtO 47 C9o. P d , 9i N s o Q �n rS _ 5 e � N ,- 55;V-ay ' Aa�NMO FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name. am-mrFrST PAE%8I T IE PU= Builder Name. DON BROWN CINST. street 583713Ttt-ST Permit Office- ZEPHYRHILLS City,State,Zip: ZEPHYRHILLS FL,33542 Pen it Number. 1 01718 Owner PREMIER Jurisdiction: 61600 Design Location: FL, Tampa County:: Pasco(Florida Climate Zone 2 1. New construction or e)dsft New(From Plans) 9. WaO Types(1617.3 sqfL) Insulation Area 4 or multiple family Single-family 2. Single family a.Concrete Bb*-Int Instill,Exterior R--5.0 1229.30 ftz b.Frame-Wood,Adjacent R=11.0 288.00 ft2 3. Number of units,if multiple family I c.WA R= fI2 4. Number of Bedroans 3 d.WA R-- ft2 5. Is this a worst case? No 10.Ceiling Types(1739.0 sqfL) Insulation Area a Under Attic(Vented) R--W.0 1739.00 fe 6. Conditioned floor area above grade(ft) 1739 b.NIA R-- ff, Conditioned flow area below grade(ft.) 0 G.WA R= ft2 11.Ducts R its 7. Windows(143.7 sqfL) Description Area a.Sup:Attic,Ret Main,AH:Main 6 347.8 a. U-Factor SgI,U=0.30 143.68 fix SHGC: SHGC--0.23 b. U-Factor: NIA. to 12. Cooling system kBhAr Efficiency SHGC: a.Central Unit 34.4 SEER:14.00 c. U-Factor NIA fe SHGC: 13. Heaft systems kBbAr Efficiency d. U-Factor. NIA fie a Electric Heat Pump 32.8 HSPF-820 SHGC: Area Weighted Average Overhang Depth: 1.333 fL Area Weighted Average SHGC. 0230 14.Hot water system 8. Floor Types (1739.0 sqfL) . Insulation Area a. Electric Cap:-40 gallons a. Slab-On-Grade Edge Insulation R=0.0 1739.00 ftZ b. Conservation fealunes EF.,0.920 b.NIA R= ft2 None c.NIA R= f12 15.Credits None Total Proposed Modified Loads'. 50.27 PASS Glass/Floor Area: 0.083 Total Baseline Loads. 52.49 I hereby certify that the plans and specifications covered by Review of the plans and 02ktE S7, this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. Before construction is completed PREPARED BY: 4r-�- pleted DATE: V1 this building will be inspected for compliance with Section 553.908 x ....... ....... I hereby certify that this tWilding,as designed,is in compliance Florida Statutes. with the Florida Energy t4de. WE OWNER/AGENT- BUILDING OFFICML DATE: DATE: - Compliance requires certification by the air handier unit manufacturer that the air handier enclosure quallifies as certified factory-seated In accordance with R403.3.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist In accordance with R402-4.1.1 and this project requires an envelope leakage tog report with envelope leakage no greater than 6.00 ACH60(R402AI.2). 5/1=18 9:27 AM EnergyGaugeO USA- FIaRes2017 Section R405.4.1 Compliant Software Page 1 of 4 FORM R405-2017 PROJECT Title: 5637 13TH ST PREMIER EPI Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1739 Lot# Owner Name: PREMIER Total Stories: 1 Block/Subd'aitsion: #of Units: 1 Worst Case: No PlalBoolc Builder Name: DON BROWN CINST. Rotate Angle: 0 Street: 563713TH ST Permit Office: ZEPHYRHILLS Cross Ventilatim: CouW.. Pasco Jurisdiction: 611600 Whole House Fan: Cily, State,Zip: ZEPHYRHILLS , Family Type: Single-family FL, 33542 New/E fisting: New(From Plans) Comment ORIENTATION NORTH HVAC VALUES SEMI TIGHT CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Sipe 97.5% 2.5% Winter Summer Degree Days Moisture Range FL, Tampa FL TAMPA INTERNATI 39 91 70 75 645.5 54 Medium BLOCKS Number Name Area Volume 1 Blockl 1739 13912 SPACES Number Name Area Volume Kfthen Occupants Bedrooms Irdd ID Fmished Cooled Heated 1 Main 1739 13912 Yes 4 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 SIa4-On-Grade Edge Insulatio Main 190 It 0 1739 ftz — 0 0 1 ROOF Roof Gable Roof Solar SA Emit Emitt Deck Pitch # Type Materials Arm Area Color Abscr. Tested Tested Insul. (deg) 1 Hip Composition shingles 1884 flz 0 ftz Medium 0.2 _ No 0.9 No 0 22.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 1739 f12 N N CEILING # Ceding Type Space R Value Ins Type Area Framing Free Truss Type 1 Under Attic(Vented) Main 30 Blown 1739 fP l 0.11 Wood 5/1/2018 9:27 AM Er gyGauge®USA-FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 4 III1 'n ICO I-4 IW IN IA Iw IN li N O 8 -I 0 N A w w N * g z m 0 g z Z N z m m 0 m cn A V W W N N N A p U7 Z i - - - ,T i i 41 N O O O O O O O �• is w w w is w .. ;i b gz o 0 0 0 0 0 0 S o r —� � mwwW W W � 0 � � MN0 � � N A Z Z Z z z Z Z z A A S' S' 9 5' w N w i i i iyy i i i D N = i o 0 0 0 0 0 0 0 cn �gy gg, N IA V `J V O O IV IV R7 IV IV Oi Oi N V OD A 0 0 0 O O O 0 O c FORM R40&2017 HEATING SYSTEM V At System Type Subtype EffiCiency Capacity Block Ducts I Electric Heat Pump/ Split HSPF.82 32.8 kBbAr I SYSS1 COOLING SYSTEM V # System Type Subtype EfttenLy Capacity Air Flow SHR Block Ducts 1 Central unit/ Sput SEER: 14 34.4 kBtu/hr 1032 ctim 0.75 1 Sy5#I HOT WATER SYSTEM V # System Type SubType Location EF Cap Use satpnt Conservation 1 Electric None Garage 0.92 40 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM VF-SEC collector Storage Cert # Company Name System Model# CkAlector Model# Area Volume FEF None None f12 DUCTS ' Supply Return Air CFM 26 CFM25 WAC# v # Location R-Value Area Location Area Leakage Type Handier TOT OUT ON RUF Heat Cool I Attic 6 347.8 ft Main 86.95 It Default Leakage Main (Default) (Default) I I TEMPERATURES Programable Thermostat None Ceifing Fans: Coorin Jan Feb Mar Apr Jun Jul DO Aug Da Dee H Jan Feb Mar A Jun Jul Oct Nov Der Jan Feb Mar Aoprr Jun Jul Oct Nov Dee H- I I tug Thermostat Schedulec HERS 20M Reference Hours Schedule Type 1 2 3 4 5 6 7 a 9 10 11 12 Goofing (WD) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Coofing(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(VVD) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating(WEH) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 5/1/2018 9:27 AM EnwgyGaugeS USA-FlaRes2017 Section R405A.1 Compliant Software Page 4 of 4 FORM R40&2017 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 96 The lower the EnergyPerformance Index,the more efficient the home. ZEPHYRHILLS , FL, 33542 vvv v rrry , 1. New construction or e>esffng New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a Concrete Block-Int Insul,E)deria R=5.0 1229.30 ft= b.3. Number of units,if multiple family 1 c.N/A-Wood,Adjacent R=11.0 288.00 R � 4. Number of Bedrooms 3 d.N/A R= ft2 5. Is this a worst case? No 10.Ceifing Types Insulation Area a Under Attic(Vented) R=30.0 1739.00 ft2 6. Conditioned floor area(ft2) 1739 b.WA R= fF 7. Windows" Description Area c.N/A R= ftz a. U Factor Sgl,U=0.30 143.68 f Z 11.Ducts R ftz a Sup:Attic,Ret Main,AH:Main 6 347.8 SHGC: SHGC=0 23 b. U-Factor. WA f12 SHGC: 12.Coding systems Mkdhr Efficiency c. U-Factor: WA ft= a Central Unit 34.4 SEER:14.00 SHGC: d. U-Factor: WA fF 13.Heating systems kBbAr Efficiency SHGC: Area Weighted Average Overhang Depth: 1.333 ft. a Electric Heat Pump 32.8 HSPF:820 Area Weighted Average SHGC: 0.230 8. Floor Types Insulation Area 14.Hot water systems gyp: a Slab-On-Grade Edge insulation R�.0 1739.00 ftz a.Electric. EF:0.92 40 gallons b.WA R= ft2 c.WA R= ft= b Conservation features None 15.Credits None I certify that this home has complied with the Florida Energy Efficiency Code for Building -ftiE sr Construction through the above energy saving features which will be installed(or exceeded) 0� `� 0 in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Date: Address of New Home: City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70,your home may qualify for energy efficient mortgage(EEM)incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation,contact the Florida Building Commission's support staff. **Label required by Setfion R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 5/1/2018 927 AM EnergyGauge®USA-FhaRes2017 -Section R405.4.1 Compliant Software Page 1 of 1 Residential System Sizing Calculation Summary PREMIER Project Title: 5637 13TH ST 5637 13TH ST PREMIER MJ TJLII 5-18 ZEPHYRHILLS, Ft.33542 ORIENTATION NORTH HVAC VALUES SEMI TIGHT 5/112018 Location for weather data: Tampa, FL -Defaults: Lafitude(27.97) Altitude(I 0 ft.) Temp Range(M) Humidity data: Interior RH(50%) Outdoor wet bulb F) Humidit v d9wenceffi4gr.) Winter design temperature(TMY3 990/6) 36 F Summer design temperature(TW3 99%) 92 F Winter setpoint 70 F Summer setpoint 75 F Winter temverature difference 34 F Summer temperature difference 17 F Total heat na load calculation 28906 Btuh Total cooling load calculation 29992 Btuh Submitted heating capacity %of talc Btuh Submitted cooling capacity %of calc Btuh Total(Electric Heat Pump) 113.5 32800 Sensible(SHR=0.75) 116.9 25800 Heat Pump+Auxiliary(O.OkW) 113.5 32800 Latent 108.5 8600 1 Total (Electric Heat Pump) 114.7 34400 WINTER CALCULATIONS Winter Heatina Load for 1739 saft) Load comDonent Load Window total 144 scift 1466 Btuh Wall total 1297 sqft 5464 Btuh Door total 77 sqft 1201 Btuh Ceiling total 1739 sqft 1883 Btuh Floor total 1739 sqft 7623 Btuh Infiltration 195 cfm 7282 Btuh Duct loss 3987 Btuh Subtotal 28906 Btuh Ventilation 0 CIM! 0 Btuh TOTAL HEAT LOSS 28906 Btuh SUMMER CALCULATIONS Summer Cooling Load for 1739 sqft) Load component Load Window total 144 sqft 2205 Btuh Wall total 1297 sqft 2192 Btuh w",I I S Door total 77 sqft 989 Btuh Ceiling total 1739 sqft 2326 Btuh Floortotal 0 Btuh Infiltration 146 elm 2731 Btuh Intemal gain 7920 Btuh Duct gain 3704 Btuh Sens.Ventilation 0 clm 0 Btuh Blower Load 0 Btuh Lz ent ant 2.i4ai 22067 Btuh n Total sensible gain Latent gain(ducts) 1763 Btuh Latent gain(infiltration) 5362 Btuh t DW-s(18.2%) Latent gain(ventilation) 0 Btuh L�Lnt,(3ain(26.4%1 Latent gain(intemaVoccupants/other) 800 Btuh Total latent gain 7925 Btuh TOTAL HEAT GAIN 29992 Btuh EnergyGaugeO System Sm 1 11-1 8th Edition PREPARE BY: DATE: EnwgyGaugeo USRCZB v6.0 Residential Window Diversity MidSummer PREMIER Project Title: 5637 13TH ST 5637 13TH ST PREMIER MJ TJLII 5-18 ZEPHYRHILLS, FL 33542 ORIENTATION NORTH WAC VALUES SEMI TIGHT 6/112018 WO Summer design temperature 92 F Average window load for July 1669 Btuh Cooling setpoint 75 F Peak window load for July 1867 Btuh Summer temperature difference 17 F Excusion limit(130%of Ave.) 2170 Btuh Latitude 27.97 North Window excursion(July) None WINDOW Average and Peak Loads ......... . ......... ........ 2,000-11 ............. t, .......800 4 1,400 10 12. 14 16 18 20 VVI n d uvv Load (8 t u N) Limit for excursi n — 12 Houfknarage ............. Total July Window Load(Radiation and conduction) The midsummer window load for this house does not exceed the window load excursion limit. This house has adequate midsummer window diversity. EnagyGaugeo System Sivi'tgf rordy PREPARED BY:r A; DATE: EnergyGaugeO I USRCZB v6.0 Residential Window Diversity October PREMIER Project Title: 5637 13TH ST 5637 13TH ST PREMIER MJ TJLII 5-18 ZEPHYRHILLS , FL 33542 ORIENTATION NORTH HVAC VALUES SEMI TIGHT 5/1/2018. ENEh. Summer design temperature 92 F Average window load for October 2843 Btuh Cooling setpoint 75 F Peak window load for October 3893 Btuh Summer temperature difference 17 F Excusion limit(130%of Ave.) 3696 Btuh Latitude 27.97 North Window excursion(October) 197 Btuh WINDOW Average and Peak Loads 155,010 - ............. 3,900 .......... 2, . ........ 1, .... . .............. ..........%, .... 50L 0 12 14 16 18 20 Windgw, Load uW) Ll mi for excursion 12 Hour Average Total October Window Load(Radiation and conduction) Warning:This application has glass areas that produce relatively large heat gains for part of the day. Variable air volume devices may be required to overcome spikes in solar gain for one or more rooms.A zoned system may be required or some rooms may require zone control. EnagyGaugeosystem Stung for Fl ony PREPARED_qY DATE: EnergyGaugeO/USRCZB v6.0 System Sizing. Calculations - Winter Residential Load - Whole House Component Details PREMIER Project Title: 563713TH ST 563713TH ST PREMIER MJ TJLII 5-18 ZEPHYRHILLS, FL 33542 Building Type: User ORIENTATION NORTH HVAC VALUES SEMI TIGHT 5/1/2018 Reference City:Tampa, FL (Defaults) Winter Temperature Difference: 34.0 F(TMY3 99%) le'1`fouse.�` - Window Panes/Type Frame U Orientation Area X HTM= Load 1 1, NFRC 0.23 Metal 0.30 W 4.9 10.2 50 Btuh 2 1, NFRC 0.23 Metal 0.30 S 25.3 10.2 258 Btuh 3 1, NFRC 0.23 Metal 0.30 S 16.5 10.2 169 Btuh 4 1, NFRC 0.23 Metal 0.30 S 40.0 10.2 408 Btuh 5 1, NFRC 0.23 Metal 0.30 E 33.1 10.2 337 Btuh 6 1, NFRC 0.23 Metal 0.30 E 7.3 10.2 75 Btuh 7 1, NFRC 0.23 Metal 0.30 N 16.5 10.2 169 Btuh Window Total 143.7 1466 Btuh Walls Type Omt. Ueff. R-Value Area X HTM= Load (Cav/Sh) 1 Cone Blk,Hollow-Ext (0.132) 5.0/0.0 39 4.47 174 Btuh 2 Frame-Wood -Adj (0.095) 11.0/0.0 110 3.23 356 Btuh 3 Frame-Wood -Adj (0.095) 11.0/0.0 160 3.23 516 Btuh 4 Cone BIKHollow-Ext (0.132) 5.0/0.0 195 4.47 873 Btuh 5 Cone Blk,Hollow-Ext (0.132) 5.0/0.0 241 4.47 1080 Btuh 6 Cone BIKHollow-Ext (0.132) 5.0/0.0 360 4.47 1609 Btuh 7 Cone Blk,Hollow-Ext (0.132) 5.0/0.0 127 4.47 570 Btuh 8 Cone BIKHollow-Ext (0.132) 5.0/0.0 64 4.47 286 Btuh Wall Total 1297 - 5464 Btuh Doors Type Storm Ueff. Area X HTM= Load 1 Wood-Exterior, n (0.460) 20 15.6 309 Btuh 2 Wood-Garage, n (0.460) 18 15.6 275 Btuh 3 Wood-Exterior, n (0.460) 40 15.6 618 Btuh Door Total 77 1201 Btuh Ceilings Type/Color/Surface Ueff. R-Value Area X HTM= Load 1 Vented Attic/L/Shing (0.032) 30.0/0.0 1739 1.1 1883 Btuh CeilingTotal 1739 188313tuh Floors Type Ueff. R-Value Size X HTM= Load 1 Slab On Grade (1.180) 0.0 190.0 ft(perim.)40.1 7623 Btuh Floor Total 1739 sqft 7623 Btuh Envelope Subtotal: 17636 Btuh Infiltration Type Wholehouse ACH Volume(cuft) Wall Ratio CFM= Natural 0.84 13912 1.00 194.8 7282 Btuh Duct load Average sealed, R6.0, Supply(Att), Retum(Con) (DLM of 0.160) 3987 Btuh All Zones Sensible Subtotal All Zones 28906 Btuh FnergyGa ugeo/USRCZB v6.0 Page 1 Manual J Winter Calculations Residential Load - Component Details (continued) PREMIER Project Title: 5637 13TH ST 5637 13TH ST PREMIER MJ TJLl1 5-18 ZEPHYRHILLS FL 33542 Building Type: User ORIENTATION NORTH HVAC VALUES SEMI TIGHT 5/1/2018 Subtotal Sensible Heat Loss 28906 Btuh Totals for Heating Ventilation Sensible Heat Loss 0 Btuh Total Heat Loss 28906 Btuh 1. Electric Heat Pump GOODMAN#GSZ140361K 32800 Btuh Key-Window Was- NFRG(Requires U-Factor and Shading coefficienKSHGQ of glass as numerical values) or-Glass as Veaf or rrmf(Uses U-Factor and SHGC defaults) U-(window U-Factor) HTM-(ManualJ Heat Transfer Multiplier) Version 8 Ener%GaugeG f USRG7-B v6.0 Page 2 stem z5. �ua a i c u t ns. 1z u m m 84 Re=�s-du-n`fa" oad - V'Jhole 11-110-use C-',ornno -rent D-4- s C, ` U. , I PREMIER Project Title: 5637 13TH ST 5637 13TH ST PREMIER MJ TJLII 5-18 ZEPHYRHILLS , FL 33542 ORIENTATION NORTH HVAC VALUES SEMI TIGHT 5/1/2018 Reference City:Tampa, FL Temperature Difference: 17.OF(TMY3 99%) Humidity difference: 54gr. Type Overhang Window Area(sqft) HTM Load Window Panes sHGC U InSh IS Ornt Len Hgt Gross Shaded Unshaded Shaded Unshaded 1 1 NFRC 0.23,0.30 No No W 1.3ft 1.0ft 4.9 02 4.7 10 27 130 Btuh 2 1 NFRC 0.23,0.30 No No S 1.3ft. I.Ok 25.3 25.3 0.0 10 11 253 Btuh 3 1 NFRC 0.23,0.30 No No S 1.31t 1.011. 16.5 16.5 0.0 10 11 165 Btuh 4 1 NFRC 0.23,0.30 No No S 1-3ft. 1.0ft. 40.0 40.0 0.0 10 11 400 Btuh 5 1 NFRC 0.23,0.30 No No E 1.3ft 1.0ft. 33.1 0.7 32.4 10 27 894 Btuh 6 1 NFRC 0.23,0.30 No No E 1.3% 1.01L 7.3 0.2 7.1 10 27 197 Btuh 7 1 NFRC 0.23,0.30 No No N 1.3k 1.01t. 16.5 0.0 16.5 10 10 165 Btuh Window Total 1 144(sqft) 2205 Btuh Walls Type U-Value R-Value Ama(sqft) HTM Load Cav/Sheath 1 Concrete BIKHollow-E)d 0.13 5.0/0.0 38.9 1.7 67 Btuh 2 Frame-Wood-Adj 0.09 11.0/0.0 110.4 1.6 178 Btuh 3 Frame-Wood-Adl 0.09 11.010.0 160.0 1.6 258 Btuh 4 Concrete BkHollow-E)d 0.13 5.0/0.0 195.1 1.7 334 Btuh 5 Concrete BlkHollow-E)d 0.13 5.0/0.0 241.3 1.7 413 Btuh 6 Concrete BlkHollow-E)d 0.13 5.0/0.0 359.6 1.7 615 Stuh 7 Concrete BkHollow-E)d 0.13 5.0/0.0 127.5 1.7 218 Btuh 8 Concrete BkHollow-E)d 0.13 5.010.0 64.0 1.7 109 Btuh Wall Total 1297(Sqft) 2192 Btuh Doors Type Area(sqft) HTM Load I Wood-Exterior 19.8 12.9 254 Btuh 2 Wood-Garage 17.6 12.9 226 Btuh 3 Wood-Exterior 39.5 12.9 509 Btuh ,Door Total 77(sqft) 989 Btuh Ceilings Type/Color/Surface U-Value R-Value Area(sqft) HTM Load 1 Vented Mc/LightlShirigle 0.032 30.010.0 1739.0 1.34 2326 Btuh Ceiling Total 1739(sqft) 2326 Btuh Floors Type R-Value Size HTM Load 1 Slab On Grade 0.0 1739(ftlmirrreter) 0.0 0 Btuh Floor Total 1739.0(sqft) 0 Btuh Envelope Subtotal: 7712 Btuh Infiltration Type Average ACH Volume(cuft)Wall Ratio CFM= Load Natural 0.63 13912 1 146.1 2731 Btuh Internal Occupants Btuh/occupant Appliance Load gain 4 X 230 + 7000 7920 Btuh Sensible Envelope Load: 18363 Btuh Duct load Average sealed„suppWR6.oAft),Re"R&o-condi) (DGM of 0.202) 3704 Btuh Sensible Load All Zones 22067 Efth EnergyGauge9/USRCZBv6.0 Page 1 Manual J Summer Calculations Residential Load - Component Details (continued) PREMIER Project Title: Climate:FL TAMPA INTERNATIONAL AP 5637 13TH ST 5637 13TH ST PREMIER MJ TJLII 5-18 ZEPHYRHILLS, FL 33542 ORIENTATION NORTH HVAC VALUES SEMI TIGHT 5/1/2018 Sensible Envelope Load All Zones 18363 Btuh Sensible Duct Load 3704 Btuh Total Sensible Zone Loads 22067 Btuh Sensible ventilation 0 Btuh Blower 0 Btuh Whole House Total sensible gain 22097 Btuh Totals for Coolin'g Latent infiltration gain(for 54 gr. humidity difference) 5362 Btuh Latent ventilation gain 0 Btuh Latent duct gain 1763 Btuh Latent occupant gain(4.0 people @ 200 Btuh per person) 800 Btuh Latent other gain 0 Btuh Latent total gain 7926 Btuh TOTAL GAIN 29992 Btuh . 1. Central Unit GOODMAN#GSZ140361 K 34400 Btuh *Key- Window types(Panes-Number and type of panes of glass) (SHGC-Shading coefficient of glass as SHGC numerical value) (U-window U-Factor) (InSh-Interior shading device:none(No),Blinds(B),Drapefies(D)or Roller Shades(R)) For Blinds:Assume medium cokir,half closed For Draperies:Assume medium weave,half dosed For Roller shades:Assume translucent,toff dosed (IS-Insect screen:none(N),Full(F)or Haff('2)) (omt-compass aiwtatim) version 8 EnergyGaugeV USRCZB v6.0 Page 2 System Sizing Calculations - Winter Residential Load - Room by Room Component Details PREMIER Project Title: 563713TH ST 563713TH ST PREMIER MJ TJLII 5-18 ZEPHYRHILLS , FL 33542 Building Type: User ORIENTATION NORTH HVAC VALUES SEMI TIGHT 5/1/2018 Reference City:Tampa, FL (Defaults) Winter Temperature Difference: 34.0 F(TMY3 99%) Window Panes/Type Frame U Orientation Any X HTM= Load 1 1, NFRC 0.23 Metal 0.30 W 4.9 10.2 50 Btuh 2 1, NFRC 0.23 Metal 0.30 S 25.3 10.2 258 Btuh 3 1, NFRC 0.23 Metal 0.30 S 16.5 10.2 169 Btuh 4 1, NFRC 0.23 Metal 0.30 S 40.0 10.2 408 Btuh 5 1, NFRC 0.23 Metal 0.30 E 33.1 10.2 337 Btuh 6 1, NFRC 0.23 Metal 0.30 E 7.3 10.2 75 Btuh 7 1, NFRC 0.23 Metal 0.30 N 16.5 10.2 169 Btuh Window Total 143.7 1466 Btuh Walls Type Omt. Ueff. R-Value Area X HTM= Load (Cav/Sh) 1 Conc Blk,Hollow-Ext (0.132) 5.0/0.0. 39 4.47 174 Btuh 2 Frame-Wood -Adj (0.095) 11.010.0 110 3.23 356 Btuh 3 Frame-Wood -Adj (0.095) 11.010.0 160. 3.23 516 Btuh 4 Conc BIk,Hollow-Ext (0.132) 5.0/0.0 195 4.47 873 Btuh 5 Conc Blk,Hollow-Ext (0.132) 5.0/0.0 241 4.47 1080 Btuh 6 . Conc Blk,Hollow-Ext (0.132) 5.010.0 360 4.47 1609 Btuh 7 Conc Blk,Hollow-Ext (0.132) 5.0/0.0 127 4.47 570 Btuh 8 Conc Blk,Hollow -Ext (0.132) 5.0/0.0 64 4.47 286 Btuh Wall Total 1297 5464 Btuh Doors Type Storm Ueff. Area X HTM= Load 1 Wood-Exterior, n (0.460) 20 15.6 309 Btuh 2 Wood-Garage, n (0.460) 18 15.6 275 Btuh 3 Wood-Exterior, n (0.460) 40 15.6 618 Btuh Door Total 77 1201 Btuh Ceilings Type/Color/Surface Ueff. R-Value Area X HTM= Load 1 Vented Attic/UShing (0.032) 30.0/0.0 1739 1.1 1883 Stuh CeilingTotal 1739 188313tuh Floors Type Ueff. R Value Size X HTM= Load 1 Slab On Grade (1.180) 0.0 190.0 ft(perim.)40.1 7623 Btuh Floor Total 1739 scift - 7623 Btuh Room Envelope Subtotal: 17636 Btuh Infiltration Type Wholehouse ACH Room Volume Wall Ratio CFM= Natural 0.84 13912 1.00 194.8 7282 Btuh Duct load Average sealed,suwly(R&O-Aft).Reum(R&Ozaw.) (DLM of 0.160) 3987 Btuh Room#1 Sensible Room Subtotal 28906 Btuh EnergyGaugeo/USRCZB v6.0 Page 1 Manual J Winter Calculations Residential Load - Component Details (continued) PREMIER Project Title: 5637 13TH ST 5637 13TH ST PREMIER MJ TJLII 5-18 ZEPHYRHILLS , Fl.33542 Building Type: User ORIENTATION NORTH HVAC VALUES SEMI TIGHT 5/1/2018 bar g, Subtotal Sensible Heat Loss 28906 Btuh Totals for Heating Ventilation Sensible Heat Loss 0 Btuh Total Heat Loss 28906 Btuh 1. Electric Heat Pump GOODMAN#GSZ140361K 32800 Btuh Key:Window types- NFRC(Requires U-Factor and Shading coeffic a SHGQ of glass as numerical values) or-Glass as Uwe orrinr(Uses U-Factor and SHGC defaults) U-(Window U-Factor) HTM-(ManualJ Heat Transfer Murdplier) Version 8 Ener%C,3uge0 USRCZB v6.0 Page 2 aa-lcud, ,7ect WY5-iftl 42h :2- Resideraba', Load - Room by Room PREMIER Project Title: 5637 13TH ST 5637 13TH ST PREMIER MJ TJLII 5-18 ZEPHYRHILLS , FL 33542 ORIENTATION NORTH HVAC VALUES SEMI TIGHT 5/1/2018 Reference City:Tampa, FL Temperature Difference: 17.0F(TMY3 99%) Humidity difference: 54gr. n' -load o Room .............. -111111...... Type Overhang Window Area(sqft) HTM Load Window Panes SHGC U InSh IS Ornt Len Hgt Gross Shaded Unshaded Shaded Unshaded 1 1 NFRC 023,0.30 No No W 1.3ft. 1.0ft 4.9 02 4.7 10 27 130 Btuh 2 1 NFRC 0.23,0.30 No No S 1.31 1.0ft. 25.3 25.3 0.0 10 11 253 Btuh 3 1 NFRC 0.23,0.30 No No S 1.3ft. 1.01t 16.5 16.5 0.0 10 11 165 Btuh 4 1 NFRC 0.23,0.30 No No S 1.3ft. 1.0% 40.0 40.0 0.0 10 11 400 Btuh 5 1 NFRC 0.23,0.30 No No E 1.3% 1.0ft. 33.1 0.7 32.4 10 27 894 Btuh 6 1 NFRC 0.23,0.30 No No E 1.3% 1.011. 7.3 0.2 7.1 10 27 197 Btuh 7 1 NFRC 0.23,0.30 No No N 1.311. 1.0% 16.5 0.0 16.5 10 10 165 Btuh Window Total 1 1 144(Sqft) 2205 Btuh Walls Type U-Value R-Value Atea(sqft) HTM Load Cav/SheEdh I Concrete BkHollow-E)d 0.13 5.0/0.0 38.9 1.7 67 Btuh 2 Frame-Wood-Adj 0.09 11.0/0.0 110.4 1.6 178 Btuh 3 Frame-Wood-Adj 0.09 11.0/0.0 160.0 1.6 258 Btuh 4 Concrete BkHollow-E)d 0.13 5.0/0.0 195.1 1.7 334 Btuh 5 Concrete BkHoHow-E)d 0.13 5.010.0 241.3 1.7 413 Btuh 6 Concrete BkHdlow-E)d 0.13 5.010.0 359.6 1.7 615 Btuh 7 Concrete BkHollow-E)d 0.13 5.0/0.0 127.5 1.7 218 Btuh 8 Concrete BkHollow-Ext 0.13 5.0/0-0 64.0 1.7 109 Btuh Wall Total 1297(sqft). 2192 Btuh Doors Type Area(sqft) HTM Load 1 Wood-Exterior 19.8 12.9 254 Btuh 2 Wood-Garage 17.6 12-9 226 Btuh 3 Wood-Exterior 39.5 12.9 509 Btuh Door Total 77(scft) 989 Btuh Ceilings Type/Color/Surface U-Value R-Value Area(sqft) HTM Load I Vented Afticfl-ight/Shingle 0.032 30.0/0.0 1739.0 1.34 23M Btuh Ceiling Total 1739(sqft) 2326 Btuh Floors Type R-Value Size HTM Load I Slab On Grade 0.0 1739(fi-perimeter) 0.0 0 Btuh Floor Total 1739.0(Sqft) 0 Btuh Zone Envelope Subtotal: 7712 Btuh Infiltration Type Wholehouse ACH Volume(cuft)Wall Ratio CFM= Load Natural 0.63 13912. 1.00 146.1 2731 Btuh Internal Occupants Btuh/occupant Appliance Load gain 4 X 230 + 7000 7920 Btuh Sensible Envelope Load: 18363 Btuh Duct load I Average sealed,SuppWR6.04ktfic),Retum(R6.0-Cond.) (DGM of 0.202) 1 3704 Btuh Sensible Zone Load 22067 Btuh EnergyGaugeO/USRCZB v6.0 Page 1 Manual J Summer Calculations Residential Load - Component Details (continued) PREMIER Project Title: Climate:FL TAMPA INTERNATIONAL AP 563713TH ST 563713TH ST PREMIER MJ TJLII 5-18 ZEPHYRHILLS, FL 33542. ORIENTATION NORTH HVAC VALUES SEMI TIGHT 5/1/2018 EnergyGaugeO/USRCZB v6.0 Page 2 Manual J Summer Calculations Residential Load - Component Details (continued) PREMIER Project Title: Climate:FL TAMPA—INTERNATIONAL AP 5637 13TH ST 5637 13TH ST PREMIER MJ TJLII 5-18 ZEPHYRHILLS , FL 33542 ORIENTATION NORTH HVAC VALUES SEMI TIGHT 5/1/2018 r. Sensible Envelope Load All Zones 18363 Btuh Sensible Duct Load 3704 Btuh Total Sensible Zone Loads 22067 Btuh Sensible ventilation 0 Btuh Blower 0 Btuh Whole House Total sensible gain 22067 Btuh Totals for Cooling Latent infiltration gain(for 54 gr. humidity difference) 5362 Btuh Latent ventilation gain 0 Btuh Latent duct gain 1763 Btuh Latent occupant gain(4.0 people @ 200 Btuh per person) 800 Btuh Latent other gain 0 Btuh Latent total gain 7925 Btuh TOTAL GAIN 29992 Btuh 1. Central Unit GOODMAN#GW140361 K 34400 Btuh *W. Window types(Panes-Number and type of panes of glass) (SHGC-Shading coefficient of glass as SHGC numerical value) (U-Window LI-Factor) (InSh-Interior shading device:none(No),Blinds(B),Draperies(D)or Roger Shades(R)) - For Blinds:Assume medium color,half dosed For Draperies:Assume medium weave,half closed For Roger shades:Assume translucent,half closed (IS-Insect screen:none(N),Full(F)or HaU('2)) (Qmt-compass orientatim) Version 8 EnergyGaugeO USRCZB WO Page 3 Air Conditioning Contractors of America Manual S (Residential Equipment Selection) , Project Information Cooling Design Information Name: PETBERLLC RES HVAC VALUES SEMI TIGHT Outdoor Design Temp:O OF db Summer City: JZEPHYRHET ORIONTATION NORTH Outdoor Design Temp:®OF db JWinter State: FL Altitude: 89 Altitude Adjustment: 1.00 Indoor Design Temp: 78 OF db ®%RH ®OF wb Manual J Load Calculations Airflow Calculations Total Load Sensible Latent SHR Heat Loss Design TD for Airflow, 17 29992 25800 4192 0.860J F-2-890-6--1 Design Sensible CFM F 58-5 L ation r GOODMAN Furnace Model#: AFUE: Coil Model# ARUF37D14A Condenser Model# GSZ140361K I SEER: 14.0 HSPF: 8.20 (A)Manufacturer's Cooling Performance Data Lower Return Air Outdoor Temperature= 92 (F db) Entering Coil Temperature=75(F db) CFM (F wb) Total BTUH Sensible BTUH Latent BTUH SHR Rated CFM @ Rated RA Temperature ® 34,400 25,800 8,600 0.75 Rated CFM @ Design RA Temperature F 1-12-0-1 ® F-31.-64-5-1 25,800 5,w 0.8153 Rated CFM @ Rated RA Temperature 60 29,992 25,800 47192 amm (B)Manufacturer's Cooling Performance Data Higher Return Air Outdoor Temperature= 92 (F db) Entering Coil Temperature=75(F db) CFM (F wb) Total BTUH Sensible BTUH Latent BTUH SHR Rated CFM @ Rated RA Temperature ® 24,400 25,800 I F-7-456-11.0574 Rated CFM @ Design RA Temperature 1380 ® 27,895 25,800 2,095 0.9249 Rated CFM @ Rated RA Temperature 60 29,992 25,800 4,192 0.8602 Manufacturer's Cooling Performance Data(Interpolated) Desig Return Air Outdoor Temperature=95(F db) CFM (F wb) Total BTUH Sensible BTUH Latent BTUH SHR 25.800 F-2.-100--1 0.9247 Excess Latent Capacity Calculation + -1,046 -F -1,046 Capacity @ Design CFM/RA(F wb) 7 ® 27,�0 24,754 3,146 0.887 Equipment Capacity as a%of Design 93.02% 95.95°k 75.04% Manufacturers Heat Pump Data Capi 1city Capacity Balance Supplemental 47 TF db Q 17'F db Point � Heat Required 32, 00 16,400 37.4 0.62 Manufacturers Furnace Data Input Output Desired Calculated Capa city Capacity AFUE Temp.Rise Airflow er tificate Of PI-Oduct Ratings AHRI Certified Reference Number:201645069 Date:04-20-2018 Model Status:Active Old AH W Reference Number:7995254 AHRI Type:HRCU-A-CB Series:GSZ14 Outdoor Unit Brand Name:GOODMAN Outdoor Unit Model Number (Condenser or Single Package):GSZ140361 IC' Indoor Unit Model Number(Evaporator and/or Air Handier):ARUF37D14A' The manufacturer of this GOODMAN product is responsible for the rating of this system combination. Rated as follows in accordance with the latest edition of ANS/AHRI 210240 with Addenda 1 and 2,Performance Rating of Unitary Air-Conditioning&Air-Source Heat Pump Equipment and subject to rating accuracy by AH W-sPOnSC red,independent,third party testing: Cooling Capacity(A2)-Single or High Stage(95F),btuh:WW SEER ::.:........ _..................... ..... :..... t HeaU - ..t n ..: I�y HSPF I - - ct. - .t,. it'.itC')<�''i`:;;�%`.%':">'!:�.'::;,`S(t`:;::' �;�:a�i',:'ri?�?t;;`i�::!.':: •y`;i'�'irci;,''_';f'%':�� £'•.i`:i'i,+.,n•L,;','.. ,•.,;,. r , i' 1 I 1 t"Active Model Status are those that an AHRI Certification Program Participant is currardly producing AND selling or oilering tar sale;OR new rrndels that are being marketed but are not yet being ptoduced.'Production Stopped'Model Status are arose that an AHRI Certification Program Participant is no longer producing BUT is still selling or offering torsale. . Ratings that are ac►�npanred by WAS iodinate an imroluntary re-rate- The new published rating is shown alone with the previous lie WAS)rating DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data fisted on this Certificate.Certified ratings are valid only for models and configurations listed In the directory at www.ahridirectory org TERMS AND CONDITIONS This.Certificate and its contents'are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes.The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated; eriteied into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual, ~MAIN personal and confidential reference. AIR-CONDITIONING,HEATING, CERTIFICATE VERIFICATION! &REFRIGERATION INSTITUTE The information for the model cited on this certificate can be verified at www.ahridirectory.org,click on"Verity Certificate'link v:c make He"Caen, and enter the AHRI Certified Reference Number and the date on which the certificate was issued, which is listed above,and the Certificate No.,which is listed at bottom right 131667073700795153.;;:';;r`:'< ©2018Air-Conditioning,Heating,and Refrigeration Institute CATE NO.: � ' SOUTHERN COMFORT ENTERPRISES, INC. 109 CR 656 WEBSTER,FL. 33597 352_?93-5e01 !2e2-5c -S!11 CACIS13579 HVAC EFFICIENCY CARD PERNIIT#: N/A DATE: DON BROWN CUSTOMER&ADDRESS:PREMIER 563713f ST ZEPHYHM,LS FL 33542 BRAND:GOODMAN CONDENSER AIR HANDLER MODEL#:GSZ140361K MODEL:ARUF37D14A COOLING SYSTEMS CAPACITY: 34.400 BTUS 3 TONS a.SDIit system SEER: 14.0 HEATING SYSTEMS CAPACITY: 34.800 BTUS 3 TONS a.Split system beat pump HSPF: 8.2 8 KW. DUCTS: LOCATION&INSULATION LEVEL: a.Supply ducts: R= 6.0 ATTIC b.Return ducts: R= 4.2 M s't c.Air Handling unit(AHU) MAIN WITH THE AUTHORIZATION OF THE INSTALLING CONTRACTOR I CERTIFY THAT THE INFORMATION ENTERED ON THIS CARD ACCURATELY REPRESENTS THE SYSTEM INSTALLED. /u AUTHORIZED SIGNATURE : l DATE • / �� AS THE BUILDING OFFICIAL OR REPRESENTATIVE OF THE BUILDING OFFICAL I CERTIFY THAT THE INFORMATION ENTER ON THIS CARD ACCURATELY REPRESENTS THE SYSTEM INSTALLED. AUTHORIZED SIGNATURE : DATE SUB-CONTRACTOR AFFIDAVIT DATE: 6/7 / TO WHOM IT MAY CONCERN: I, Thous Lachance , d/b/a Southern Comfort Fes.Inc. License Number: CAC1813579 will be the Mechanical wMactor for this permit application. The job address is: 5637 13�h 5t Ze 1115 �G. 335 - &&awe of License Holder or Auffimized Agent STATE OF: FLORIDA COUNTY OF: SUMTER I HEREBY CERTIFY that the foregoing instrument was aclmowledged before me this - day'of /Yl Q�/ ,20J 'by .Thomas i uhmwe _who is personally lmown to me.. } Sigoattme ofNotary c PWR Notary Puthc State of Florida c- ver, +� usio G 190714 �i�p Expires 02/27/2022 Jacqueline Boges From: City of Zephyrhills Support<support@zephyrhillsfl.zendesk.com> Sent: Wednesday, June 6, 2018 1:52 PM To: Jacqueline Boges Subject: [Request received] 38654 9th ave by#19718 service ##- Please type your reply above this line -## Hello Jacqueline Boges, We are working to resolve your request promptly and will keep you updated. One of our Support Analysts will keep you updated on the progress of your request. Best Regards, FATHOM Support Team TO ADD ADDITIONAL COMMENTS, reply to this email or click the link below: https://zephyrhilisfl.zendesk.com/hc/requests/218713 ...................................................................... ....................................................................................................................................................................................................................................................................................................... Jacqueline Boges I Jun 6, 10:52 AM MST full service 38654 9th ave by#1971 8 water, sewer, water meter This email is a service from City of Zephyrhills Support . i CITY OF / / I BUILDING ZEPHYRHILLS DEPARTMENT OF ADDITION OR CORRECTION D • NOT REMOVE ADDRESS DATE PERMIT 2_ q THIS JOB HAS NOT BEEN COMPLETED, The following additions or corrections shall be made before the job will be accepted. 10(17 �7 -s- 6 ' It is unlawful for any Carpenter,Contractor,Builder,or other persons,to AFTER CORRECTIONS ARE MADE CALL cover or cause to be covered,any part of the work with flooring,lath,earth 78�-��20 FO R ECTION or other material,until the proper inspector has had ample time to approve the installation. OFFICE HOURS 7:30AM-4:30 PM MON.-FRI. INSPECTOR Central Testing Laboratory ......................... . . ..... Engineering and Materials Testing .... .. .... ..... ............... ..... .... ..... .... ...... . ............. Reply to: FIELD DENSITY WORKSHEET CLIENT: DATE: % w f �S PROJECTNO.: PROJECT NAME: PERMIT NO.: EARTH CONTRACTOR: TESTED BY: % COMPACTION: 61 �3-'C;'io FIELD CONTACT: TOTAL ON SITE TIME: MILES FROM OFFICE: STANDARD MODIFIED BUILDING PAD BUILDING FOOTING PIPE BACKFILL BASE SUBGRADE ( TEST LOCATION LAB PROCTOR TEST PROBE WIDTH ELEV. %MOIST. WET DRY %COMP. OMC DENS. DEPTH DEPTH LIFTS DENS. DENS. (om e o COMMENTS: VIA L-)A boay� Density failed to meet minimum project requirement. Retest indicates minimum density requirement was obtained. Client is aware of unsatisfactory test results. 5400 S. Florida Avenue 130 Satellite Ct. Sumter County Marion County Inverness, FL 34450 Leesburg, FL 34748 (352)793-3110 (352)622-1186 (352)726-6447 (352)787-1268 CTL0898 FDW Jacqueline Boges From: MWConstruction <Florida.support@duke-energy.com> Sent: Thursday, June 28, 2018 11:49 AM To: Jacqueline Boges Subject: RE: FW: temp power request[T20180628015DS010Z10029562] Good Afternoon, An application is required for service. Thanks Adrienne --- Original Message--- On June 28, 2018 at 10:47 AM, "Jacqueline Boges" wrote: *** Exercise caution. This is an EXTERNAL email. DO NOT open attachments or click links from unknown senders or unexpected email. *** Contractor is insisting to me that you did not receive this release. I am forwarding over to you again... From: Jacqueline Boges Sent: Monday, June 25, 2018 3:44 PM To: Duke Energy(floridamunicipalities@duke-eriergy.com) <floridamunicipalities@duke-energy.com> Subject: temp power request Hello, Jackie, here in the City of Zephyrhills I am requesting release for a construction pole(temp service) for the address of 38654 9 h Ave by#19718. Please could you acknowledge receipt of this email as it will show as release given and become part of the permit file. Thank you 1 Jacqueline Boges From: Nichole Spence(City of Zephyrhills Support)<support@zephyrhillsfl.zendesk.com> Sent: Wednesday, June 6, 2018 2:27 PM To: Jacqueline Boges Subject: [FATHOM] Re: 38654 9th ave by#19718 service ##- Please type your reply above this line -## Your request (#218713) has been updated. REPLY TO THIS EMAIL or click the link below: https://zephvrhillsfl.zendesk.com/hc/requests/218713 ............................................................................................................................................................................................................................................................................................................................................................................ Nichole Spence (City of Zephyrhills Support ) ' - Jun 6, 1 1 :27 AM MST Account# 2992509 has been created, service order to follow once mapping has been completed. Best Regards, Nichole I FATHOM Support ..................... . . . ........................................... ............... ................... .............................. ................. ................................................................................................. ......................................... ............... Jacqueline Boges Jun 6, 10:52 AM MST full service 38654 9th ave by#,�19.fi71!&wate�r, sewer, water meter This email is a service from City of Zephyrhills Support . i