HomeMy WebLinkAbout18-19774 CITY`OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 19774 FIRE SPRINKLER SYSTEM PERMIT PERMIT INFORMATION LOCATION INFORMATION Permit Number: 19774 Address: 7425 GALL BLVD Permit Type: FIRE SPRINKLER SYSTEM ZEPHYRHILLS, FL. Class of Work: FIRE-SPRINKLER SYS Township: Range: Book: Proposed Use: COMMERCIAL Lot(s): Block: Section: Square Feet: Subdivision: CITY OF ZEPHYRHILLS Est. Value: Parcel Number: 34-25-21-0000-00300-0000 Improv. Cost: 1,506.00 OWNER INFORMATION Date Issued: 6/08/2018 Name: ZEPHYRHILLS PLAZA LLC Total Fees: 175.00 Address: 7425 GALL BLVD Amount Paid: 175.00 ZEPHYRHILLS, FL. 33542 Date Paid: 6/08/2018 Phone: Work Desc: ADD SPRINKLER HEAD TO EXISTING SYSTEM- BEAL'S OUTLET CONTRACTORS APPLICATION FEES WAYNE AUTOMATIC FIRE SPRINKLER FIRE SPRINKLER SYS 50.00 FIRE PLAN REVIEW FEES 50.00 FIRE INSPECTION FEES 45.00 CONTRACTOR CERTIFICATE 30.00 I COW Ins ections Re d FIRE-PRESSURE TEST FIRE ACCEPTANCE Final Chapter 633, Florida Statutes,authorizes the City to charge and collect user fees to pay for the costs of fire prevention and protection related activities such as inspections, plan review, administrative fees,and other costs related to the aforementioned. Complete Plans, Specifications and Fee Must Accompany Application. Commencement of work without written approval of the Fire Department's Fire Marshal or required permits or opening up for commercial activity without an approved final inspection shall be charged double permit fee per day of operation or a minimum of$100.00, whichever is greater. All work shall be performed in accordance with City Codes and Ordinances. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMEN ENT." bO—NTRACTOR SIGNATURE PERMIT OFFICE PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOURS NOTICE REQUIRED ZEPHYRHILLS FIRE RESCUE DEPT- 813-780-0041 813-780-0020 , City of Zephyrhills Fire FaX-813-780-0021 � Permit Application Date Received Phone Contact for Permit Owner's Name ZepKyrhills Plaza LLC Owner's Phone Number Owner's Address 5236 Commercial Way Spring Hill FL 34606-1995 Fee Simple Titleholder Name Titleholder Phone Number Fee Simple Titleholder Address Job Address 7425 Gall Blvd. Zephyrhills FL. Lot# Sub Division Parcel ;B:T;AN�DF M�_F.�TiY_ -�NOTI mu'*azard Waste Storage AmwuxL Fumigation Tent Comm Exhaust Kitchen Hood/Duct Hazardous Material(Tier xnreu Facility)ANNUAL Controlled Burn Hood Installation Emergency Generator=oomw LP/wotura|oas-msmxat/or Emergency Generator"oo** Lpvwamra|Gas-ANNUAL Sale Fire Protection Maintenance xmmuAL [ � Places mAssembly-ANNUAL r7trly F—enil rA—nil Sprinkler o o o Recreational Burn p/remonn o o o F7 Sparklers Hood Cleaning o o o �pnnmoravm�mm��|�mons �� ___— * o ^ /*vouaupp�umvn L_] o o � ] [ 1 ��nun�e�(aponmu,or� | / Fire Alarm Installation Torch noonnonarKettle Fire Pumps ---- Waste'rine Storage ANNUAL / Flammable Application-ANNUAL $ 1,506 Valuation ofProject rmmrenx -- _ —F_X]__other: Adding 1 Sprinkler to existing sprinkler system. '_— Contractor Company Wayne Automatic Fire Sprinklers In�j Signature ure Registered _Y/N�] Fee Current _),/N�] Address 3226 Cherry Palm Dr. Tampa, FL License sLscTn|omw Company Signature Registered Y/lV_1 Fee Current _Y'/«�] Address License# puymosn Company Signature vre Registered _Y/1N_] Fee Current _.//`N_� Address License# mEoxxw|cAL Company Si gnature Registered [_Y/N_ Fee Current (/N] xuoreoo License# or*sR Company Signature on ure Registered _Y/N Fee Current Y��_] Address License#J Directions: Fill out uppmxatiuocompletely. . Owner&Contractor sign back of application,notarized(Or,copy of signed contract with owner) If over$25mo'a Notice n,Commencement is required(Mechanical work over*soo0) Supply two(2)sets o,drawings with applicable documentation m/vw 1u-14 days for review after submittal date. Parcel#'obtained from Property Tax Notice(hup:xonpraisecnascoom//mm) ` , NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to^deod°restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake mmrk, they may be required to be licensed in accordance with state and |moa| regulations. If the contractor is not |inoneod as required by }aw, both the owner and contractor may be cited fora misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended wmrk, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at727'O47- 8UO8. Furthermone, if the owner has hired a contractor or oontradom, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, an the owner sign as the contnoctor, that may be an indication that he in not properly licensed and is not entitled ho permitting privileges in Pasco County. CONSTRUCTION LIEN LAW(Chapter?13, Florida Statutes, eoamendmd): |f valuation of work io $3.508.00urmore, | certify that |` the app|ioont, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver itto the"owmor"prior tocommencement. - CONTRACTOR'S/OWNER'S AFFIDAVIT: | certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating oonobuution, zoning and land development. Application is hereby made to obtain o permit to do work and installation as indicated. | certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all |amm regulating oonmtruotion. County and City oudeo, zoning regulations, and land development regulations in the jurisdiction. | also certify that | understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take toboincompliance. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. | understand that a separate permit may be required for electrical work, p|umbing, eigno, vveUa, poo|o, air cmnd/tioning, gaa, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit iueuance, or if work authorized by the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension may be requosted, in writing, from the Building Official for period not to exceed ninety (QO) days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90) consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. OWNER OR AGENT CONTRACTOR Subscribed and sworn to(or affirmed)before me this Subscribo and sworn to(or affirme before me this Who is/are personally known to me or has/have produced Who is/are person me or has/have produced as identification. as identification. Notary Publiu Notary Public ZEP:HYRHILLS FIRE :DEPARTMENT 38410.6t h Ave.Zephyrhills; FL: 33542 . FIRE SERVICE USER FEES increase 1/112018 . .Occupancy No.: Plan No.: Contractor: Business:Name:. S'G Billing Address: Business Address: Business Phone No.: :Billing Phone:No:: Business Fax No:: Billing Fax No.: Contact:. Contact... PLAN REVIEW FEES. INSPECTION FEES, PERMIT FEE Annual- Education,healthcare,De tention&Correctional Public Assembly,Business,. schools, Storage,Mercantile and Churches Site Plan N/C Industrial. no charge. Sprinkler. $50 Multi-Family/Commercial :03 sf up.to 800 sq ft $ .24.00 Standpipes $50 " (Minimum Charge$24:00 801 -1;500 sq ft: $ 34.52 Fire Pump.: $50 Plan Revisions . - DBG 1,501 -2,500 sq ft $. 60:02 Hoods $50 - - 2,501=3,500,sq ft $ 90.02 Fire Alarm $50 SPRINKLER-SYSTEMS 3',501=5,000 sq ft $ 127.52 . LP Gas $50 . 0.-25 Heads. $50 5,501-7,500 sq:ft : $: 187.52. Natural Gas : $50 26 plus Heads $100 7,501=10,000 sq ft. $. 262:52 . Fuel Tanks- per tank ' $50 STANDPIPE SYSTEM 10;001-15,000 sq ft $ V5.02 Sparklers $100 n Per Riser $50, 1,5,00,1-20,000 sq ft $ .525.02 Fire Works. $500 . . FIRE PUMP. 20,001-30,000 sq ft $ 750.02 Camp Fire(recreation' .$25 Per Pump $100 .30,001740,000 sq ft $ 1',050,.02 Controlled Burh(15da-, $100 FIRE ALARM.SYSTEM 40,001-60,000 sq ft $ 1,500.02. Hood/Duct $50 0-25 Devices. $50 60,001-60,000 sq ft. $ 2,160.02 Place of Assembly .$50 Annual . 80;001-($2,100.02)per 26 plus Devices: $100 ea add 1,000sq ft $ 0.06 Fire Protection $25. . SUPPRESSION SYSTEMS (Business closed until Flammable Application $50 Annual Wet $50 violations corrected) Waste Tire Storage: $50 Annual Dry. $50. SPRINKLER SYSTEMS . Generator<KW. $100. CO2 $50 Hydro Undergrounds $45 Generator>30 KW $100. Other. $50 Hydrostatic Test• $65 Per system Bio-Hazard.Waste: $100:Annual KITCHEN EXHAUST Acceptance Test - $45 per system Fumigation Tenting $50 Hood/Ducts $50 . '.Hydrant Flow $75 Torch Pot/Applied $50 . OTHER Haz:Materials $50. Annual LP Installation per tank $50 FIRE ALARM SYSTEM Fuel Tank Installation $50. System Acceptance $50 (Per Tank) $50 Recall Acceptance $50 FI Natural Gas Installation '$50, OTHER (Per System Fire Wall/Smoke Wall $15. Per well Spray Booth $50 LP'Gas $25 per tank. Natural Gas $25 per system Tent 10'x10'or greater $15 per tent Fire Pump $45 Fire_Suppression $30 System Acceptance . Exhaust Hood/Duct $30 Re-inspection DBL . (other than annual) Inspection scheduled DBL and cancelled less than 24:hours. . . Construction Insp. N/C eh cce 0 Emergency V 'cle.A $5 PLANS TOTAL INSPECTION TOTAL PERMIT TOT GRAND.TOTAL Comments:" Date: Inspector: see back . : nm FALSE,ALARM FEE. .1st Alarm. N/C . 2nd Alarm N/C, . 3rd Alarm N/C . : 4th-Alarm $100 5th Alarm_ $150 6th Alarm $200 NON COMPLIANCE $150 .Cont.Annual Inspection Fees 3-11 Units price per unit. $ 5.36 12-25 Units.price per unit ' $ 4.82 26-50 Units price per unit. $ 4.29 51A00 Units price per unit $ 3.75 100 or more Units price per unit .$ 2.68 Fire Safety re-inspection types First Re inspectiol N/C Second re-inspecf :$75 Third.re-inspectior $ 125.00 Inspection scheduled but cancelled 24 hrs : $ 50.00 TOTAL Alh APWAYNE Automatic Fire Sprinklers,Inc 5/7/2018 To:City of Zephyrhills, 5335 8th St,Zephyrhills, FL 33542 I Charles E Price II-of Wayne Automatic Fire Sprinklers,authorize the listed names to submit and pick up permits under my license; Chase Price,Vincent Como, Michael Grant,James Boyette,Joe Taylor. Thank you, (License # FPC17-000106) Wayne Automatic Fire Sprinkler, Inc. 3226 Cherry Palm Drive "AwPLA"'�, DELN4. DEAN My C;OMW�510N#G601,9692 Tampa, Florida 33619 --XPI ,2020 AES..August U Oc Regional Office: 3226 Cherry Palm Drive•Tampa, FL. 33610 • Phone: (813),630-0303 Fax: (813) 630-0312 Ocoee - Pompano - Fort Myers - Jacksonville. - Concord, NC �_.°HyllO Hlllfl City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: Date Received: Site: cTa-,,O—p(_ 86"c Permit Type: --fir iLD Approved w/no comments:�/ Approved w/the below comments: ❑ Denied w/the below comments: ❑ This comment sheet shall be kept with the permit and/or plans. 6 -q. 4 Gene Brown—Fire Safety Officer Date Contractor and/or Homeowner (Required when comments are present) BEALLS # 30. 7425 GALL BLVD, ZEPHYRHILLS, FL SUBMITTAL DATA WAYNE Automatic Fire Sprinklers, Inc. 3226 CHERRY PALM DRIVE TAMPA, FLORIDA 33619 PHONE 813-630-0303 - FAX: 813-630-0312 F I TT I Sm WAY N 1E Automatic Fire Sprinklers, Inc. Wayne Automatic Fire Sprinklers (W.A.F.S.) utilizes "Threadable Thinwall" piping for sizes V through 2". It is sometimes referred to as Schedule 30. Per NFPA 13, section 6.3.6.1, it is permissible to use piping other than that provided in Table 6.3.1.1 provided it is listed. Piping will be sourced from domestic manufacturers. Piping will be manufactured in accordance with the following standard: • ASTM A795 - Standard Specification for Black and Hot-Dipped Zinc- Coated (Galvanized) Welded and Seamless Steel Pipe for Fire Protection Use. • ASTM 135 - Standard for electric resistance welded steel pipe. All piping will be UL listed & FM approved. Pipe will be from one of the following manufacturers: Allied 11Dyna Thread" • Bull moose Tube Company "Eddythread.40" • Welded Tube - Berkeley G°Steady-Thread" • Wheatland Tube Company "Mega-Thread" • Youngstown Tube °°EZ-Thread" Corporate Office: 222 Capitol Court• Ocoee, Florida 34761-3033 (407) 656-3030• Fax(407) 656-8626 Regional Offices: Jacksonville Fort Myers • Pompano Beach • Tampa -- Concord, NC D.I. THREADED FITTINGS, STUOPIPEPRODUCTS N— LISTED LISTED APPROVED For fire protection services request submittal GRS 1.3 Ductile�—'iron threaded--fittings are -_ --- _listed and factory mutual_approved for_' psi service.Ductile iron per ASTM A 536 grade e5-45-12.Dimensions conform to ANSIa1a.3 class 15l Threads are NPTPsANSNAS3NEB1.2V1.' / p NOTICE:Ductile iron fittings have higher tensile strength than that of steel pipe.Therefore, ' over tightening can cause damage to pipe threads which may cause leakage.Ductile iron L—z— ��ngdohou|db o�ghtonedthomotumubmyondhonddghd.butnomono8/on1hurtumo. ` ' DUCTILE IRON 90 DEG. ELBOW NOMINAL ITEM MAX. DIM SIONS WEIGHT SIZE CODE WORIUNG EACH DUCTILE IRON 45 DEG. ELBOW NOMINAL ITEM MAX. DIM IONS SIZE CODE WOMNG EACH SIZE CODE WOPJUNG EACH ~~ � � ! 77 i -�f~- �—_A__~� DUCTILE IRON COUPLING MAX. DIMENSION -W-E-1GRr NOMINAL ITEM DUCTILE IRON RED. COUPLING SIZE CODE WORKJNG EACH NOMINAL ITM— MAX. DIMENSION -WM-dW Page 21 D.I. THREADED FITTINGS STAR®PIPEPRODUCTS U L FM O O LISTED LISTED APPROVED For fire protection services request submittal GRS 1.3 E DUCTILE IRON REDUCING TEE l NOMINAL ITEM MAX. DIMENSIONS WEIGHT _ i I SIZE CODE WORFdNG EACH (INCH) # P.S.I. A B C PIECE 1X1X3 4 DT332 500 1.37 1.37 1.45 0.73 1X3 4X1 DT323 500 1.50 1.45 1.50 0.76 1X1X112 DT335 500 1.80 1.80 1.65 1.16 1 1 4X1X3 4 DT432 500 1.45 1.37 1.62 0.90 1 1 4 1X1 1 4 DT434 500 1.75 1 1.67 1.75 1.08 E . 80 11 X114X12 gD32 500 1.34 1.34 1.53 0.86 ..1_ 1 1 4X1 1 4X 500 1.58 1.58 1.67 0.95 �_- OUTSIDE HEAD INSIDE HEAD 1 1 4X1 1 4X2 500 2.10 2.10 1.90 1.75 DUCTILE •N BUSHINGS 1 1 2X1X3 4 500 1.52 1.37 1.75 1.14 NOMINAL ITEM DIMENSIONS I12X1X114 DT534 500 1.82 1.67 1.88 1.34 SIZE CODE ' S sTv�e 112X114 12 T541 500 1.4 1.34 1.66 1.05 (INCH) # A BF EACH 5 1x1/2 DBUSH31 0.75 0.25 1.42 OUT 0.22 112 14X1 DT543 500 1.65 1.58 1.80 1.25 1x3/4 DBUSH32 0.75 0.25 1.42 OUT 0.17 2 5 6 500 2. 6 -2-.TO- 2. .15 112X112 12 T551 500 1.41 1.41 1.1616 1.15 1 1/4x1 DBUSH43 0.80 0.28 1.76 OUT 0.28 2 2 3 552 500 .52 1.52 .75 .2 1 1/2x1 DBUSH53 0.83 0.31 2.00 OUT 0.44 1 1 2 1 1 2X1 DT553 500 1.65 1.65 1.80 1.30 1 1/2x1 114 DBUSH54 0.83 0.31 2.00 OUT 0.30 2 2 5 5 .8 .82 11 2 1 1 2X2 DT636 500 2.25 2.02 2.25 1.98 2x1 DBUSH63 0.88 0.41 1.95 IN 0.66 2 6 500 2.25 2. 2.25 2. 5 2x1 1/4 IDBUSH64 0.88 0.34 2.48 OUT 0.72 2X1 1 4X2 DT646 500 2.25 2.10 2.25 2.30 2x1 1/2 DBUSH65 0.88 10.3412.48 JOLIT0.61 2X1 1J2X1/265 50 9 88 .5 2X1 1 2X3 4 DT652 500 1.60 1.52 1.97 1.62 2X112X114 DT654 500 1.90 1.82 2.10 1.80 2X112X2 DT656 500 2.25 2.16 2.25 2.35 Ef 'E-'? 2 X3 4 DT662 500 1.60 1.60 1.97 1.68 2X2X1 1 4 DT664 500 1.90 1.90 2.10 2.04 I2X2X212 DT667 500 2.60 2.60 2.39 3.61 -<. i= A DUCTILE IRON • NOMINAL ITEM MAX. DIMENSIONS WEIGHT r- ----- ' SIZE CODE WORFdNG EACH DUCTILE • ■ (INCH) # P.S.I A B PIECE 1 DX033 500 1.50 1.50 0.98 NOMINAL ITEM MAX. DIMENSION WEIGHT 11/4 DX044 500 1.75 1.75 1.50 SIZE CODE WOPIUNG EACH 11/2 DX055 500 1.94 1.94 1.90 (INCH) # P.S.I. A PIECE 2 DX066 500 2.25 2.25 2.95 1 DCP003 500 1.16 0.32 11/4X1 DX043 500 1.58 1.67 1.27 11/4 DCP004 500 1.28 0.43 11/2X1 DX053 500 1.65 1.80 1.48 11/2 DCP005 500 1.33 0.60 2X1 DX063 500 1.73 2.02 2.10 2 DCP006 500 1.45 0.91 Page 22 Beam Clams ANVI .Star- pFire Products Division of Anvil'International = ANVIL Universal C-type Clamp (Standard Throat) SIZE RANGE:3/8 and 1/2" MATERIAL:Ductile iron,hardened steel cup point set screw and locknut. FINISH: Plain or Galvanized SERVICE: Recommended For use under roof installations with bar joist type construction, a `s• or for attachment to the top or bottom flange of structural shapes where the vertical hanger rod is required to be offset from the edge of the flange and where the thickness of joist or flange does not exceed 3/4". = a+ APPROVALS:Complies with Federal Specification A-A-1192A(Type 19&23),WW-H- '8 171-E(Type 23)and MSS-SP-69(Type 19&23). V*015 UL,ULC Listed and FM Approved. � t HOW TO SIZE:Size of clamp is determined by size of rod to be used. UL LC INSTALLATION:Follow recommended set screw torque values per FM MSS-SP-69(See table on page PF-212) APPROVED FEATURES: For Listing/Approval Details and Limitations visit our Web Site • They may be attached to horizontal flanges of structural members in either the top beam www.anvilinti.com or contact an or bottom beam positions. Anvil®/AnvilStarrm Sales Representative. • Secured in place by a cup-pointed Set Screw tightened against the flange.A Jam Nut is provided for tightening the Set Screw against the Body Casting. • Thru tapping of the body casting permits extended adjustment of the threaded rod. • Can be used with Fig 89X retaining clip for seismic applications. r\ I H C�I F E AT LEAST ONE G I FULL OD READ OFROFRXP 'Yl -- BE EXPOSEDSED 3/a' I D r'�f / -•- BODY CASTING JAM-NUT —fA �`�•'-�',,,1 SET SCREW Rod Size Set Screw Max Loads■ A Size Weight C D E F G H Top Bottom In. In. lbs. tbs. tbs. in. In. In. In. In. In. 3/8 3/8 500 250 0.34 15/16 19/16 9/16 13/16 3/8 1/2 1/2 1/2 950 760 0.63 13/8 113/16 1/2 11/16 9/16 23/32 ■Maximum temperature of 450°F Refer to the Pipe Hanger Catalog for Additional Parts available on Anvil's Web Site www.anvilinti.com Anvil®Pipe Hangers &Supports www.anvilstar.com REV.05.23.06-007 ProValii` t °r Professional Quality. Exceptional Value. Threaded Rod q PV# DESCRIPTION SIZE THREADS TENSILE APPLICATION ASTM PER INCH STRENGTH(PSI) PV35592 ALL THREAD ROD ZINC 1/4 x 6 20 60,000 INT /EXT A307-03 PV35593 ALL THREAD ROD ZINC 1/4 x 10 20 60,000 INT /EXT A307-03 PV35594 ALL THREAD ROD ZINC 3/8 x 6 16 60,000 INT / EXT A307-03 PV35595 ALL THREAD ROD ZINC 3/8 x 10 16 60,000 INT /EXT A307-03 PV35596 ALL THREAD ROD ZINC 3/8 x 12 16 60,000 INT /EXT A307-03 PV35597 ALL THREAD ROD ZINC 1/2 x 6 13 60,000 INT / EXT A307-03 PV35598 ALL THREAD ROD ZINC 1/2 x 10 13 60,000 INT /EXT A307-03 PV35600 ALL THREAD ROD ZINC 5/8 x 6 11 60,000 INT /EXT A307-03 PV35601 ALL THREAD ROD ZINC 5/8 x 10 11 60,000 INT /EXT A307-03 PV35602 ALL THREAD ROD ZINC 3/4 x 6 10 60,000 INT /EXT A307-03 PV35603 ALL THREAD ROD ZINC 3/4 x 12 10 60,000 INT / EXT A307-03 PV35604 ALL THREAD ROD STNLS 1/4 x 10 20 60,000 INT / EXT N /A PV35605 ALL THREAD ROD STNLS 3/8 x 10 16 60,000 INT /EXT N /A PV35606 ALL THREAD ROD STNLS 1/2 x 10 13 60,000 INT /EXT N /A PV35607 ALL THREAD ROD STNLS 3/4 x 6 10 60,000 INT / EXT N /A PV35608 ALL THREAD ROD PLAIN 3/8 x 6 16 60,000 INT A307-03 PV35609 ALL THREAD ROD PLAIN 3/8 x 10 16 60,000 INT A307-03 PV35610 ALL THREAD ROD PLAIN 3/4 x 6 10 60,000 INT A307-03 PV35611 ALL THREAD ROD PLAIN 3/4 x 12 10 60,000 INT A307-03 PV35612 ALL THREAD ROD STAINLESS 1/4 x 6 20 60,000 INT /EXT N /A PV35613 ALL THREAD ROD STAINLESS 3/8 x 6 16 60,000 INT /EXT N /A PV35614 ALL THREAD ROD STAINLESS 1/2 x 6 13 60,000 INT /EXT N /A PV35615 ALL THREAD ROD STAINLESS 5/8 x 6 11 60,000 INT /EXT N /A PV35616 ALL THREAD ROD STAINLESS 5/8 x 10 11 60,000 INT / EXT N /A PV35617 ALL THREAD ROD STAINLESS 3/4 x 10 10 60,000 INT /EXT N /A PV35636 ALL THREAD ROD PLAIN 1/2 x 10 13 60,000 INT A307-03 PV35637 ALL THREAD ROD PLAIN 5/8 x 10 11 60,000 INT A307-03 provahv TOLCO wWWAOICO.Com abmdofffd1E3CCY Revision 00 Fig. 200 - "Trimline" Adjustable Band Hanger C UL US LISTED Size Range— 1/2" thru 8" pipe FM Material —Carbon Steel, Mil. Galvanized to G90o specifications Function — For fire sprinkler and other general piping , purposes. Knurled swivel nut design permits hanger tilt adjustment after installation. Features — • (1/2" thru 2") Flared edges ease installation for all pipe types and protect CPVC plastic pipe from t abrasion. Captured design keeps adjusting nut _ from separating with hanger. Hanger is easily B l + a I installed around pipe. A I • (21/2" thru 8") Spring tension on nut holds it A 1 securely in hanger before installation. Adjusting � nut is easily removed. Approvals— Underwriters' Laboratories listed (1/2" thru 8") in the USA (UL) and Canada (cUL) for steel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4" thru 8"). Conforms to Federal 1/2 THRU 2 INCH PIPE 2 1/2 THRU 8 INCH PIPE Specifications WW-H-171 E, Type 10 and Manufacturers Standardization Society SP-69,Type 10. Maximum Temperature—650OF Finish — Mil. Galvanized. For Stainless Steel materi- als, order TOLCOO Fig. 200WON. Order By— Figure number and pipe size 1 i l � Dimensions •Weights Pipe Rod Size Max. Rec. Approx. Size Inch Metric A B Load Lbs. Wt./100 1/2 3/8 8mm or 10mm 31/8 25/8 400 11 3/4 3/8 8mm or 10mm 31/8 21/2 400 11 1 3/8 8mm or 1 Omm 33/8 25/8 400 12 11/4 3/8 8mm or 10mm 33/4 27/8 400 13 11/2 3/8 8mm or 1 Omm 37/8 27/8 400 14 2 3/8 8mm or 10mm 41/2 3 400 15 21/2 3/8 10mm 55/8 41/8 600 27 3 3/8 10mm 57/8 4 600 29 31/2 3/8 10mm 73/8 51/4 600 34 4 3/8 1Omm 73/8 5 1000 35 5 1/2 12mm 91/8 61/4 1250 66 6 1/2 12mm 101/8 63/4 1250 73 8 1/2 12mm 131/8 83/4 1250 136 OFFICE/MANUFACTURING FACILITY•1375 SAMPSON AVE.•CORONA,CA 92879•PH: 951.737.5599•FAX: 951.737.0330 i CUSTOMER SERVICE•800.786.5266 www.tolco.com t' CO Fire Suppression & Building Products Technical Services 800-381-9312 1+1-4017781-8220 www.tyco-fire.com Series TY-FRB — 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Corrosion-resistant coatings, where applicable, are utilized to extend the R life of copper alloy sprinklers beyond Description that which would otherwise be obtained :7_ �.,. when exposed to corrosive atmo- The TYCO Series TY-FRB,2.8,4.2,5.6, it;E mzs its" spheres.Although corrosion-res resistant and 8.0 K-factor, Upright and Pendent coated sprinklers have passed the Sprinklers described in this data sheet standard corrosion tests of the appli- nfrr.c are quick response,standard coverage, cable approval agencies,the testing is decorative 3 mm glass bulb-type spray {, poss ible e cor- f a poss sprinklers designed for use in light or not representative o ros ordinary hazard,commercial occupan- ive atmospheres. Consequently, it is recommended that the end user � cies such as banks, hotels, and shop- ping malls. be consulted with respect to the suit- ability of these coatings for any given The recessed version of the Series TY- corrosive environment.The effects of FRB Pendent Sprinkler,where applica- ambient temperature, concentration of ?� ble, is intended for use in areas with a chemicals, and gas/chemical velocity, SA finished ceiling.This recessed pendent should be considered, as a minimum, I sprinkler uses one of the following, along with the corrosive nature of the �.,.- .- • chemical to which the sprinklers will be A two-piece Style 10 (1/2 inch NPT) p or Style 40(3/4 inch NPT) Recessed exposed. I'(: Escutcheon with 1/2 inch(12,7 mm)of An intermediate level of the Series TY- -NIA &l. i recessed adjustment or up to 3/4 inch FRB Pendent Sprinklers is detailed 19,1 mm of total adjustment from the ( ) J in Technical Data Sheet TFP356, and flush pendent position,or a Sprinkler Guards are detailed in Tech- • A two-piece Style 20 (1/2 inch NPT) nical Data Sheet TFP780. or Style 30 (3/4 inch NPT) Recessed Escutcheon with 1/4 inch(6,4 mm)of �/� recessed adjustment or up to 1/2 inch The Series TY--FRB Concealed Pendent ModellSprinkler (12,7 mm)of total adjustment from the Sprinklers described herein must be flush pendent position. installed and maintained in compliance Identification The adjustment provided by the with this document and with the appli- Number (SIN) Recessed Escutcheon reduces the cable standards of the National"Fire accuracy to which the fixed pipe drops Protection Association, in addition to to the sprinklers must be cut. the standards of any authorities having TY1131: Upright 2.8K, 1/2-NPT jurisdiction. Failure to do so may impair TY1231: Pendent 2.8K,1/2 NPT the performance of these devices. TY2131: Upright 4.2K,1/2-NPT Owners are responsible for maintaining TY2231: Pendent 4.21K,1/2-NPT their fire protection system and devices TY3131: Upright 5.61K,1/2-NPT in proper operating condition. The TY3231: Pendent 5.6K,1/2-NPT IMPORTANT installing contractor or sprinkler manu- TY4131: Upright 8.0K,3/47NPT Always refer to Technical Data facturer should be contacted with any TY4231: Pendent 8.01K,3/4"NPT Sheet TFP700 for the "INSTALLER questions. TY4831: Upright* 8.OK, 1/2-NPT WARNING' that provides cautions TY4931: Pendent* 8.OK, 1/2-NPT with respect to handling and installation of sprinkler systems and components. Improper handling and installation can permanently damage a sprinkler system or its components and cause the sprinkler to "fail to operate in a fire situation or cause it to operate prematurely. 'Eastern Hemisphere Sales Only Page 1 of 10 JULY 2010 TFP171 TFP171 Page 2 of 10 7/16"(11,1 mm) ESCUTCHEON STYLE 10 or 20 SSU* NOMINAL PLATE SEATING RECESSED DEFLECTOR MAKE-IN NPT SURFACE ESCUTCHEON 6* 5 7/16" 4 (11,1 mm) �— 2-1/4" NOMINAL (57,2 mm) 2 MAKE-IN 3 2-3/16" 1-9/16" (55,6 mm) WRENCH (39,7 mm) 1 FLATS . 7 1/2"NPT SSP DEFLECTOR* 2-7/8"(73,0 mm)DIA. CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT 1 -Frame 3-Sealing 4-Bulb 6'-Deflector Assembly 'Temperature rating is indicated on deflector or adjacent to 2-Button 5-Compression 7-gushing orifice seat on frame. Screw'. FIGURE 1 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY1131)AND PENDENT(TY1231)SPRINKLERS 2.8 K-FACTOR, 112 INCH NPT 7/16"(11,1 mm) ESCUTCHEON STYLE 10 or 20 SSU* NOMINAL PLATE SEATING RECESSED DEFLECTOR MAKE-IN NPT SURFACE ESCUTCHEON 6* J 5 7/16" (11,1 mm) �— 2-3/16" 4 NOMINAL (55,6 mm) MAKE-IN 2 2-3/16" 1-1/2" W(55,6 mm) WRENCH (38,1 rhm) 3 FLATS 1 1/2"NPT SSP DEFLECTOR* 2-7/8"(73,0 mm)DIA. CROSS SECTION- UPRIGHT PENDENT RECESSED PENDENT - 1 -Frame 3-Sealing 4-Bulb 6-Deflector Assembly 'Temperature rating is indicated on deflector or adjacent to 2-Button 5-Compression orifice seat on frame. Screw FIGURE 2 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY2131)AND PENDENT(TY2231)SPRINKLERS 4.2 K-FACTOR, 112 INCH NPT TFP171 Page 3 of 10 7/16"(11,1 mm) ESCUTCHEON STYLE 10 or 20 SSU* NOMINAL PLATE SEATING RECESSED DEFLECTOR MAKE-IN NPT SURFACE ESCUTCHEON 6* 5T 7/16" (11,1 mm) 2-3/16" 4NOMINAL (55,6 mm) MAKE-IN 2 -3/16" (38,11/mm) ,6 mm) WRENCH 3 FLATS 1 1/2"NPT SSP DEFLECTOR* 2-7/8"(73,0 mm)DIA. CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT 1 -Frame 3-Sealing 4-Bulb 6-Deflector Assembly "Temperature rating is indicated on deflector or adjacent to 2-Button 5-Compression orifice seat on frame. Screw FIGURE 3 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY3131)AND PENDENT(TY3231)SPRINKLERS 5.6 K-FACTOR, 1121NCH NPT 1/2"(12,7 mm) ESCUTCHEON STYLE 30 or 40 SSU* NOMINAL PLATE SEATING RECESSED DEFLECTOR MATE-IN NPT SURFACE ESCUTCHEON 6* � 5 1/2" (12,7 rnm)!n7 2-5/16" 4 NOMINAL (58,7 mm) MAKE-IN 2 2-1/4" 1-9/16" (57,2 mm) v (39,7 mm) 3 1 � , 3/4"NPT SSP DEFLECTOR* 2-7/8"(73,0 mm)DIA. CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT 1-Frame 3-Sealing 4-Bulb 6-Deflector Assembly 'Temperature rating is indicated on deflector or adjacent to 2-Button 5-Compression orifice seat on frame. Screw FIGURE 4 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY4131)AND PENDENT(TY4231)SPRINKLERS 8.0 K-FACTOR, 314 INCH NPT ^ TFP171 . . . � Page 4of1O Ssu NOMINAL DEFLECTOR MAKE-IN 1/2" NPT NOMINAL 3 FLATS CROSS 1/2"NPT DEFLECTOR SECTION UPRIGHT PENDENT 1 -Frame 3-Sealing 4-Bulb 6-Deflector Temperature rating is indicated on deflector or adjacent to 2-Button Assembly 5-Compression odfice seat on frame. Screw FIGURE 5 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY4831)AND PENDENT(TY4931)SPRINKLERS �� ^�"��� �� ��m� f�M� ��F���md m ��m�mmmmm���mm n���~~~ ~~�m��m� tho280^F/14/*C �������m The g|omo Bulb contains o fluid that temperature ratings. -- ----- expands when exposed to heat.When Obtain a leak-tight 1/2 inch NPT sprin- Approvals the rated temperature ia reached, the kler joint by applying a minimum UL and C-ULListed fluid expands sufficiently to shatter the maximum torque of7tn /4/t/bo (9,5 FIVIj-PCB.andNYCApp/oved glass Bu|b, allowing the sprinkler to of torque Refer to Table A and B for complete activate and water 1oflow. can distort the sprinklerInlet with con- approval information including oequont leakage or impairment nfthe corrosion-resistant status. De sprinkler~~ up/ Maximum Working Pressure D" not attempt to - bs for Refer to Table C' Criteria insufficient adjustment'� -------h Plate under-or over-tightening Discharge Coefficient The TYCO Series TY'FRB Pendent the sprinkler. Re-adjust the position of K=2' '8QPW o 0^3LpM/barl and Upright Sprinklers are intonded the sprinkler fitting tvsuit.K=4.2GPK 'p"i`� O'5LPW/bar`m fnrOropn���o�on~�~^~ '~deak]nedin The Series TY-FRB Pendent and aonondannowiihthoo\anda/dinota||a' m K=5OGP[W/poi, (8O0LPyW/bar,n) -------- ''-� ---'---- '-'-- Upright Sprinklers must be installed ' �- ' Uon rules recognized by the applicable K 8DGPK4/pai�m �152LPK8/ba�/� \n accordance with the following = ' ' Listing TenmperatuvyR�bng Listing im based nn the mquim instructions ' Refer hu Table/\and 8' NFpA13/ W�»dF� APPn�/a|isba»edu» 1. Install Pendent sprinklers in the thnnx��|mm*ntaofFK�'nLnuaProven- pendent position. Install upright Finishes tion Data Sheets). Only the Style 10. sprinklers in the upright position. Sprinkler: Refer tn Table A and B. 2O'8U'»r40 Recessed Escutcheon,»» 2 Withpipe-threadaea|an(applied to Recessed Eacutchoon�VVhitoCoagod applicable, iotobeuandforroonaeed ' Chrome p|��odorBru'sP|ated ' pendent thep�othmadn' han�-t�htenthe ' » � installations. sprinkler into the sprinkler fitting. Physical Characteristics ��������0�~���^��� 3� Tight the sprinkler into the ap/in Framo. . . . . . . . . . . . . . . � � � . Bronze ~�~~~�~~~~���~~-~~ Werfitt�g using on| the Bu�mn. . . . . . . . . .. . . .Bnano/C The TYCO Series TY-FRBSprinklers Sprinkler Wrench (Figure 14). With Sealing Assembly. . . . . . . . .Beryl|ium must be installed in accordance with reference to Figures 1 through Nicka|w/TeOont the following instructions. 5' apply the VVqype G Sprinkler Bulb . . . . . . . . . . . . . . . . . . . . . .Glass Wrench to the sprinkler wrench Compression Screw. . . . . . . . Bronze flats. Deflector. . . . . . . . . . .Copper/Bronze Bushing U<=2.0 . . . . . . . . . . . Bronze uo not install any bulb-type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the kler held horizontally, a small air bub- ble should be present. The diameter !Registered Trademark mDupont ~' the air~ bubble~approximately 1116 ` TFP171 Page 5 of 10 SPRINKLER FINISH(See Note 5) K BULB LIQUID NATURAL CHROME WHITE*** FACTOR TYPE TEMPERATURE COLOR BRASS PLATED POLYESTER 135°F/57°C Orange PENDENT 155°F/68°C Red (TY1231) - and 175°F/79°C Yellow 1,2,3,4 UPRIGHT(TY1131) 200°F/93°C Green 286°F/141°C Blue 135°F/57°C Orange 2.8 RECESSED 155°F/68°C Red 1/2"NPT PENDENT (TY1231)* 175°F/79°C Yellow Figure 6 200°F/93°C Green 1,2,4 135°F/57°C Orange RECESSED PENDENT 155°F/68°C Red (TY1231)** 175°F/79°C Yellow Figure 7 200°F/93°C Green 135°F/57°C Orange PENDENT 155°F/68°C Red (TY2231) and 175°F/79°C Yellow UPRIGHT(TY2131) 200°F/93°C Green 286°F/141°C Blue 135°F/57°C Orange 4.2 RECESSED 1/2"NPT PENDENT 155°F/68°C Red 1,2 (TY2231)* 175°F/79°C Yellow Figure 8 200°F/93°0 Green 135°F/57°C Orange RECESSED PENDENT 155°F/68°C Red (TY2231)** 175°F/79°C Yellow Figure 9 200°F/93°C Green NOTES: 1. Listed by Underwriters Laboratories,Inc.,(UL)as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories,Inc.,for use in Canada(C-UL)as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation(FM)as Quick Response Sprinklers. 4. Approved by the City of New York under MEA 354-01-E. 5. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. ` Installed with Style 10(1/2"NPT)or Style 40(3/4"NPT)3/4"Total Adjustment Recessed Escutcheon,as applicable. "Installed with Style 20(1/2"NPT)or Style 30(3/4"NPT)-1/2"Total Adjustment Recessed Escutcheon,as applicable. ***Frame and Deflector only.Listings and approvals apply to color(Special Order). N/A:Not Available TABLE A LABORATORY LISTINGS AND APPROVALS FOR 2.8 AND 4.2 K-FACTOR SPRINKLERS TFP171 Page 6 Of 10 SPRINKLER FINISH(See Note 8) K TYPE TEMPERATURE BULB LIQUID NATURAL CHROME WHITE*** LEAD FACTOR COLOR BRASS PLATED POLYESTER COATED 135°F/57°C Orange PENDENT(TY3231) 155°F/68°C Red and 175°F/79°C Yellow 1,2,3,4,5,6,7 1,2,3,5 UPRIGHT 200°F/93°C Green (TY3131) 286°F/141°C Blue 135°F/57°C Orange RECESSED 155°F/68°C Red 5.6 PENDENT 1/2"NPT (TY3231)* 175°F/79°C Yellow 1,2,4,5 N/A Figure 10 200°F/93°C Green 286°F/141°C Blue 135°F/57°C Orange RECESSED 155°F/68°C Red PENDENT 175°F/79°C Yellow 1,2,3,4,5 N/A (TY3231)** Figure 11 200°F/93°C Green 286°F/141°C Blue 135°F/57°C Orange PENDENT(TY4231) 155°F/68°C Red and 175°F/79°C Yellow 1,2,3,4,5,6,7 1,2,5 UPRIGHT 200°F/93°C Green (TY4131) 286°F/141°C Blue 135°F/57°C Orange RECESSED 155°F/68°C Red 8.0 PENDENT 175°F/79°C Yellow 1,2,5 N/A 3/4"NPT (TY4231)* Figure 12 200°F/93°C Green 286°F/141°C Blue 135°F/57°C Orange RECESSED 155°F/68°C Red PENDENT 175°F/79°C Yellow 1,2,3,5 N/A (TY4231)** Figure 13 200°F/93°C Green 286°F/141°C Blue 135°F/57°C Orange 8.0 PENDENT(TY4931) 155°F/68°C Red 1/2"NPT and 175°F/79°C Yellow 1,2,4,5,6 1,2,5 UPRIGHT 200°F/93°C Green (TY4831) 286°F/141°C Blue NOTES: 1. Listed by Underwriters Laboratories,Inc.,(UL)as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories,Inc.,for use in Canada(C-UL)as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation(FM)as Quick Response Sprinklers. 4. Approved by the Loss Prevention Certification Board(LPCB Ref.No.007k/04)as Quick Response Sprinklers.However,LPCB does not rate the thermal sensitivity of recessed sprinklers. 5. Approved by the City of New York under MEA 354-01-E. 6. VdS Approved(For details,contact Tyco Fire Suppression&Building Products,Enschede,Netherlands,Tel,31-53-428-4444/Fax 31-53-428-3377.) 7. Approved by the Loss Prevention Certification Board(LPCB Ref.No.094a/06)as Quick Response Sprinklers. 8. Where Polyester Coated and Lead-Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers.Where Lead-Coated Sprinklers are noted to be FM Approved,the sprinklers are FM Approved as a Corrosion-Resistant Sprinklers. *Installed with Style 10(1/2"NPT)or Style 40(3/4"NPT)3/4"Total Adjustment Recessed Escutcheon,as applicable. **Installed with Style 20(1/2"NPT)or Style 30(3/4"NPT)1/2"Total Adjustment Recessed Escutcheon,as applicable. **'Frame and Deflector only.Listings and approvals apply to color(Special Order). N/A:Not Available TABLE B LABORATORY LISTINGS AND APPROVALS FOR 5.6 AND 8.0 K-FACTOR SPRINKLERS TFP171 Page 7 of 10 SPRINKLER FINISH K TYPE NATURAL I CHROME WHITE LEAD FACTOR BRASS PLATED POLYESTER COATED PENDENT(TY1231) and 2.8 UPRIGHT(TY1131) 175 PSI(12,1 BAR) N/A 1/2"NPT RECESSED PENDENT(TY1231) PENDENT(TY2231) and 4.2 UPRIGHT(TY2131) 175 PSI(12,1 BAR) N/A 1/2"NPT RECESSED PENDENT(TY2231) PENDENT(TY3231) 175 PSI and UPRIGHT(TY3131) 250 PSI(17,2 BAR) (12,1 BAR) 5.6 OR 175 PSI(12,1 BAR) 1/2"NPT RECESSED (SEE NOTE 1)PENDENT(TY3231) N/A PENDENT(TY4231) 175 PSI and (12,1 BAR) 8.0 UPRIGHT(TY4131) 175 PSI(12,1 BAR) 3/4"NPT RECESSED N/A PENDENT(TY4231) 8.0 PENDENT(TY4931) 175 PSI 1/2"NPT UPRIGHand T(TY4831) 175 PSI(12,1 BAR) (12,1 BAR) NOTES: 1. The maximum working pressure of 250 psi(17,2 bar)only applies to the Listing by Underwriters Laboratories Inc.(UL);the Listing by Underwriters Laboratories,Inc.for use in Canada(C-UL);and,the Approval by the City of New York. TABLE C MAXIMUM WORKING PRESSURE The Series TY-FRB Recessed Pendent '+ Exercise care to avoid damage to Sprinklers must be installed in accor- Care and sprinklers before, during, and after dance with the following instructions. Maintenance installation. Never paint, plate, coat, 1. After installing the Style 10, 20, 30, or otherwise alter automatic sprinklers or 40 Mounting Plate, as applica- The TYCO Series TY-FRB must be after they leave the factory. ble, over the sprinkler threads and maintained and serviced in accordance Replace sprinklers that: with pipe-thread sealant applied to with the following instructions. a were modified or over-heated. the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. • were damaged by dropping,striking, wrench twisting,wrench slippage,or 2. Tighten the sprinkler into the sprin- Before closing a fire protection system the like. kler fitting using only the W Type 7 main control valve for maintenance, . are leaking or exhibiting visible signs Recessed Sprinkler Wrench (Fig- work on the fire protection system of corrosion. ure 15).With reference to Figures 1 that it controls, obtain permission to to 4, apply the W Type 7 Recessed shut down the affected fire protection • were exposed to corrosive products Sprinkler Wrench to the sprinkler systems from the proper authorities of combustion but have not oper- wrench flats. and notify all personnel who may be ated, if you cannot easily remove 3. After ceiling installation and finish- affected by this action. combustion by-products with a cloth. ing,slide on the Style 10,20,30, or Absence of the outer piece of an • have a cracked bulb or have lost liq- 40 Closure over the Series TY=FRB escutcheon, which is used to cover uid from the bulb. Refer to the Instal- Sprinkler and push the Closure over a clearance hole, can delay sprinkler lation section in this data sheet. the Mounting Plate until its flange operation in a fire situation. comes in contact with the ceiling. TFP171 Page Qof1O FACE OF (57,2 mm) MOUNTING FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING M) 2 41/4"DIA� MOUNTING MOUNTING SURFACE SURFACE FIGURE 6 FIGURE 7 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 314 INCH TOTAL ADJUSTMENT WITH TWO-PIECE 112 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON FACE OF MOUNTING FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING 71 1- I E/ Miil T MOUNTING MOUNTING SURFACE FIGURE 8 FIGURE 9 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 314 INCH TOTAL ADJUSTMENT WITH TWO-PIECE 112 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON Initial and frequent visual inspections of Responsibility |ioo with the owner for Care must be exercised to avoid dam- random oam les are recommendedhzr the inspection, testing, and ainto- age to the sprinklers -before, during, corrosion-resistant sprinklers to verify nance of their fire protection system and after installation. Sprinklers dam- the integrity of the corrosion-resistant and devices in compliance with this aged by dropping, striking, wrench material of construction. Thereafter, document, as well as with the appli- twist/slippage, or the like, must be annual inspections per NFPA 25 should cable standards of the National Fire replaced. Also, replace any sprinkler suffice. Protection Association (for example, that has u cracked bulb or that has lost |' nrauti~ '� of `~''~~i~' '~~i~t~' t NFPA25). in addition tu the standards liquid from its bulb. (RntInstallation ofanyotherouthoritieohav�gjuriudio' Section). . range, instead of from -o the floor level ti«n.Contact the installing contractor o/ Initial and frequent visual inspections of per — pA Inspection close|ooe range sprinkler m er manufacturer regarding any random samples aoommondedfor oatta-detormin- heactoprin- questions. corrosion-resistant sprinklers tnverify Ner condition andthe long-term into Automatic sprinkler systems are nan- the integrity of the corrosion-resistant rdyof the corrosion-resistant material, ommondedtobo inspected, teoted, material of construction. Thereafter, which can bo affected by the corrosive and maintained bya qualified Inupac- annual inspections per NFPA25should conditions present. don Service in accordance with local suffice. requirements and/or national codes. TFP171 Page 9 of 10 2-7/8"DIA. 2-7/8"DIA. 5/8±1/4" (73,0 mm) 3/4"(19,1 mm) (73,0 mm) 1/2" 12,7 mm (15,9±6,4 mm) 2-1/4"DIA. 1/4"(6,4 mm) (12,7±3,2 mm) 2-1/4"DIA. 1/4"(6,4 mm) FACE OF (57,2 mm) (57,2 mm)FACE OF MOUNTING � MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING 1/8" 1/8" (3,2 mm) (3,2 mm) MOUNTING MOUNTING SURFACE SURFACE CLOSURE SERIES 1-1/4"(31,8 mm) CLOSURE SERIES 1-1/4"(31,8 mm) TY-FRB 3/4"(19,1 mm) TY-FRB 1"(25,4 mm) FIGURE 10 FIGURE 11 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 314 INCH TOTAL ADJUSTMENT WITH TWO-PIECE 112 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 112 INCH NPT 5.6 K-FACTOR, 112 INCH NPT 2-7/8"DIA. 2-7/8"DIA. 5/8±1/4" (73,0 mm) 3/4"(19,1 mm) 1/2+1/8" (73,0 mm) 1/2"(12,7 mm) (15,9±6,4 mm) 2-1/4" DIA. 1/4"(6,4 mm) (12,7±3,2 mm) 2-1/4"DIA. 1/4"(6,4 mm) (57,2 mm) FACE OF (57,2 mm) � MOUNTING FACE OF MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING 1/8" 1/8" (3,2 mm) (3,2 mm) MOUNTING G71 SURFACE SURFACE CLOSURE SERIES 1-5/16"(33,3 mm) CLOSURE SERIES 1-5/16"(33,3 mm) TY-FRB 13/16"(20,6 mm) TY-FRB 1-1/16"(27,0 mm) FIGURE 12 FIGURE 13 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 314 INCH TOTAL ADJUSTMENT WITH TWO-PIECE 112 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR, 314 INCH NPT 8.0 K-FACTOR, 314 INCH NPT Inspections of corrosion-resistant sprinklers are recommended at close WRENCH range, instead of from the floor level RECESS per NFPA. Inspection at close range WRENCH RECESS can better determine the exact sprin- (END"A" USED FOR kler condition and the long-term integ- 1/2" NPT MODELS) rity of the corrosion-resistant material, which can be affected by the corrosive conditions present. WRENCH RECESS (END"B" USED FOR 3/4" NPT MODELS) PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH FIGURE 14 SPRINKLER WRENCHING AREA W-TYPE 6 SPRINKLER FIGURE 15 WRENCH W-TYPE 7 RECESSED SPRINKLER WRENCH �. TFP171 Page 1Omf1O P/N 57 XXX X XXX TEMPERATURE MODEL/SIN SPRINKLER RATINGS I FINISH ^Eastern Hemisphere sales only. TABLE D PART NUMBER SELECTION SERIES TY-FRJ PENDENT AND UPRIGHT SPRINKLERS Limited ������ responsible for e h h|oroyatemdoaign Ordering ��immmm����� anomorinaccur�oor incomplete info� medion supplied by Buyer or Buyer's Wha rra n ty representatives. ' moc ~dume Products manufactured by Tyco Fire In no event ohe|| TFSBp be liable, in Contact your local distributor for Suppression & Building Products uontnuct, tort, atho1 liability orunder avai|obi|by. When� ' | ing— an order, (TFSB warranted solely tothe any other legal theory, fo incidental, indicate the full product name and Part original Buyerforton(1U)years against indirect,npou/m|orconsequentialdam' Number(P/N). defects in material and workmanship ages,including but o|limited to laborwhonpaNforand properly installed charges, regardless owhotherTFSBp Sprinkler Assemblies with and maintained under normal use and was informed about the— ` — Thr ead aarv�o' This -- , w@| - - --' ouuh ow/ and event shad( Specify: (Specify Model/SIN), Quick (10) years from data of shipment TFGBP's liability exceed an amount /roo� No warranty equalto�exa�aphce Response, (specify 'perature rating), Series Ti-FRB ucts or components manufactured by companies not affiliated by ownership The foregoing warranty is made in lieu (specify Pendent or Upright)Sprinkler with TFSBP or for products and com- o any and all other warranties,express with(specify type of finish or coating), ponents which have been subject to or.mplied,including warranties of mer P/N (specify from Table D). misuse, improper installation, corro- chantability and fitness for a particula Recessed Escutcheon: oion, or which have not been installed, purpose. Specify: or 40 nmaintaned, modified or repaired in This limited warranty sets forth the Recessed Escutcheon with (apeoify*) accordance with applicable Standando exclusive remedy for claims based on finish, P/N (sPacifY~)^ of the National Fire Protection An000io- failure ofor defect in products, matmri' bon and/or the standards cf any other a|sor components,whether the claim ia Sprinkler Wrench Authorities Having Jurisdiction. Mate- mad* in contract,tort, strict liability or Specify: YV 0 Sprinkler Wrench, ria|a found by TFSBP to be defective any other legal theory. P/N 56'000'6-387 shall be either repaired replaced, at TFSBP'o sole option. '' SBp neither This warranty will apply to the full Specify: V 7 Sprinkler Wrench, assumes, nor authorizes any person extent permittedby|mw.Tho |nva|idity, FYN5S-8S0-4-0O1. to assume for it other obligation in in whole»r part, of any portionof this ��m�� Refer Data � � �aSheT7 . connection with the sale of productsor warranty will not affect the remainder. parts of products.TFSBP shall not be Copyright 0 2007-2010 Tyco Fire Suppression&Building Products.All rights reserved. BEALLS #30, 7425 GALL BLVD, ZEPHYRHILLS, FL SUBMITTAL DATA ' WAYNE Automatic Fire Sprinklers, Inc. 3226 CHERRY PALM DRIVE TAMPA, FLORIDA 33619 PHONE 813-630-0303 - FAX: 813-630-0312 PIPE & FITTI... N G S WAYNE Automatic Fire Sprinklers, Inc. Wayne Automatic Fire Sprinklers (W.A.F.S.) utilizes "Threadable Thinwall" piping for sizes V through 211. It is sometimes referred to as Schedule 30. Per NFPA 13, section 6.3.6.1, it is permissible to use piping other than that provided in Table 6.3.1.1 provided it is listed. Piping will be-sourced from domestic manufacturers. Piping will be manufactured in accordance with the following standard: • ASTM A795 - Standard Specification for Black and Hot-Dipped Zinc- Coated (Galvanized) Welded and Seamless Steel Pipe for Fire Protection Use. • ASTM 135 - Standard for electric resistance welded steel pipe. All piping will be UL listed & FM approved. Pipe will be from one of the following manufacturers: • Allied 11Dyna Thread" • Bull moose Tube Company "Eddythread 40" • Welded Tube - Berkeley "Steady-Thread" • Wheatland Tube Company "Mega-Thread" • Youngstown Tube IIEZ-Thread" Corporate Office: 222 Capitol Court• Ocoee, Florida 34761-3033 • (407)656-3030• Fax(407) 656-8026 Regional Offices: Jacksonville • ,Fort Myers • Pompano Beach • Tampa -- Concord, NC D.I. THREADED FITTINGS STUWPEPRODUCTS LISTED LISTED APPROVED For fire protection services request submittal GRS 1.3 Ductile iron threaded fittings are UL,LILC listed and factory mutual approved for 500 psi service.Ductile iron perASTM A 536 grade 65-45-12.Dimensions conform to ANSI B1 6.3 class 150.Threads are NPT per ANSI/ASME 131.20.1. P, NOTICE:Ductile iron fittings have higher tensile strength than that of steel pipe.Therefore, i over tightening can cause damage to pipe threads which may cause leakage.Ductile iron fitflngd should be tightened theree turns beyond hand fight,but no more than four turns. DUCTILE IRON 90 DEG. ELBOW NOMINAL ITEM MAX. DIMENSIONS WEIGHT SIZE CODE WORKING ................ EACH (INCH) # P.S.I. A B PIECE I DB90033 Soo 1.50 1.50 0.62 11/4 DB90044 Soo 1.75 1.75 0.90 11/2 DB90055 500 1.94 1.94 1.20 I DB900661 500 1 2.25 1 2.25 1 1.85 1 DUCTILE IRON 45 DEG. ELBOW NOMINAL ITEM MAX. DIMENSIONS WEIGHT SIZE CODE WORKING EACH (INCH) # P.S.I. A B PIECE I DB45033 500 1.12 1.12 0.46 DUCTILE IRON RED.90 DEG. ELBOW 1114 DB45044 500 1.29 1.29 0.73 11/2 5055 500 1.43 1.43 0.92 NOMINAL ITEM MAX. DIMENSIONS WEIGHT 2 DB45066 500 MNE1.50 SIZE CODE WOR19NG EACH (INCH) # P,S.I. A B PIECE 1X1/2 DB90031 Soo 1.26 1.36 0.44 1 X3/4 DB900321 500 1.37 1.45 0.52 I 1/4XI/2 DB90041 500 1.34 1.53 0.64 I 1/4X3/4 DB90042 Soo 1.45 1.62 0.72 1 1/4XII DB90043 500 1.58 1.67 0.75 1 112XI DB90053 500 1.65 1.80 0.92 DUCTILE IRON STRAIGHT TEE I 112XI 1/4 DB90054 500 1.82 1.88 1.08 NOMINAL ITEM MAX. DIMENSIONS DIM SIONS E 72XI/2 DB90061 Soo 1.49 1.88 1.08 SIZE CODE WORKING EACH 2X3/4 DB90062 Soo 1.60 1.97 1.24 (INCH) # P.S.I. A B PIECE 2X1 DB90063 Soo 1.73 2.02 1.40 2X1114 DB90064 Soo 1.90 2.10 1.52 1 DT333 Soo 1.50 1.50T0.85 2X1 1/2 DB90065 Soo 2.02 .2.16 1.65 11/4 DT444 -500 1.75 1.75 1.22 1112 DT555 500 1 1.94 1.94 1.55 2 DT666 500 1 2.25 1 2.25 2.45 7------- 0 A DUCTILE IRON COUPLING NOMINAL ITEM MAX. DIMENSION WEIGHT SIZE CODE WORKING EACH DUCTILE IRONCOUPLING (INCH) # P.S.I. A PIECE .......... NOMINAL ITEM MAX. DIMENSION WEIGHT 1 DCL033 500 1.67 0.40 SIZE CODE WORKING EACH 11/4 DCLO44 500 1.93 0.57 (INCH) # P.S.I. A PIECE 11/2 DCLO55 500 2,15 0.75 1X1/2 DRC031 500 1.69 0.39 2 DCL066 500 2.53 1.15 1 X3/4 DRC032 500 1,69 0.53 Page 21 D.I. THREADED FITTINGS STAR®PIPEPRODUCTS U FM O O LISTED LISTED APPROVED For fire protection services request submittal GRS 1.3 DUCTILE • REDUCING j NOMINAL ITEM MAX. DIMENSIONS WEIGHT SIZE CODE WORIUNG EACH INCH # P.S.I. A B C PIECE 1X1X3 4 DT332 500 1.37 1.37 1.45 0.73 1 3 4 1 DT323 500 1.50 1.45 1.50 0.76 1X1X112 DT335 500 1.80 1.80 1.65 1.16 1 1 4X1X3 4 DT432 500 1.45 f3-7 1.62 0.90 C - - r 1 1 4X1X1 1 4 5T434 500 1.75 1.67 1.75 1.08 r,- �. )- 1 1 4X1 1 4X1 2 DT441 500 1.34 1.34 1.53 0.86 114X11I4 1 DT443 500 1.58 1.58 .67 0.95 i OUTSIDE HEAD INSIDE HEAD 1 1 4X1 1 4X2 5T446 500 2.10 2.10 1.90 1.75 • BUSHINGS1 1 2X1X3 4 DT532 500 1.52 1.37DUCTILE IR 1.75 1.14 NOMINAL ITEM DIMENSIONS I12X1X114 DT534 500 1.82 1.67 .88 1.34 SIZE CODE STYLE EACH 112X114X12 T541 500 1.41 1.34 1.66 1.05 (INCH) # A B C EAC 1x1/2 DBUSH31 0.75 0.25 1.42 OUT 0.22 1 1 2X114X1 DT543 500 1.65 1.58 1.80 1.25 1x3/4 DBUSH32 0.75 0.25 1.42 OUT 0.17 2 5 6 500 2. 6 2 0. 2. .15 112X 12X12 DT551 500 1.4 1.41 1.1616 1.15 1 1/4x1 DBUSH43 0.80 0.28 1.76 OUT 0.28 1 112X13 552 5 0 .52 .52 .75 .2 1 1/2x1 DBUSH53 0.83 0.31 2.00 OUT 0.44 11 2X11 2 1 DT553 500 1.65 1.65 1.80 1.30 1 1/2x1 1/4 DBUSH54 0.83 0.31 2.00 OUT 0.30 2 2 5 500 .82 .82 .88 8 2x1 DBUSH63 0.88 0.41 1.95 IN 0.66 1 1 2X1 1 2 I T556 500 2.16 2.16 T02 1.98 2X1X2 DT636500 2.25 2.02 5 --T1 5 2x1 114 DBUSH64 0.88 0.34 2.48 OUT 0.72 2X11 4X2 DT646 500 2.25 2.10 2.25 2.30 2x1 1/2 DBUSH65 0.88 0.34 2.48 OUT 0.61 2 2 65 5 0 9 T. .62 2X1 1 2X3 4 DT652 500 1.60 1.52 1.97 1.62 2X112X 14 DT654 500 1.90 1.82 2.10 1.80 5 2X112 DT656 500 2.25 2.16 2.25 2.35 �re •?_ B- i �$ 2X2X3 4 DT662 500 1.60 1.60 1.97 1.68 2X2X114 DT664 500 1.96 1.90 2.10 2.04 2X2X212 DT667 500 2.60 2.60 2.39 3.61 j A A DUCTILE IRON • NOMINAL ITEM MAX. DIMENSIONS WEIGHT - _ -- SIZE CODE WORIUNG EACH DUCTILE • . (INCH) # P.S.I A B PIECE 1 DX033 500 1.50 1.50 0.98 NOMINAL ITEM MAX. DIMENSION WEIGHT 11/4 DX044 500 1.75 1.75 1.50 SIZE CODE WORIUNG EACH 1112 DX055 500 1.94 1.94 1.90 (INCH) # P.S.I. A PIECE 2 DX066 500 2.25 2.25 2.95 1 DCP003 500 1.16 0.32 11/4X1 DX043 500 1.58 1.67 1.27 11/4 DCP004 500 1.28 0.43 11/2X1 DX053 500 1.65 1.80 1.48 11/2 DCP005 500 1.33 0.60 2X1 DX063 500 1.73 2.02 2.10 2 DCP006 500 1.45 0.91 Page 22 Beam Clams A StarTM pFire Products Division of Anvil*International Universal C-type Clamp (Standard Throat) SIZE RANGE:3/8 and 1/2" — I� — MATERIAL:Ductile iron,hardened steel cup point set screw and locknut. R° FINISH: Plain or Galvanized SERVICE:Recommended for use under roof installations with bar joist type construction, - or for attachment to the top or bottom flange of structural shapes where the vertical hanger rod is required to be offset from the edge of the flange and where the thickness of joist or flange does not exceed 3/4". APPROVALS:Complies with Federal Specification A-A-1192A(Type 19&23),WW-H- 171-E(Type 23)and MSS-SP-69(Type 19&23). UL,ULC Listed and FM Approved. HOW TO SIZE:Size of clamp is determined by size of rod to be used. UL lC INSTALLATION:Follow recommended set screw torque values per FM MSS-SP-69(See table on page PF-212) APPROVED FEATURES: For Listing/Approval Details and Limitations visit our Web Site • They may be attached to horizontal flanges of structural members in either the top beam www.anvilinli.com or contact an or bottom beam positions. Anvil®/AnvilSlarTm Sales Representative. • Secured in place by a cup-pointed Set Screw tightened against the flange.A Jam Nut is provided for tightening the Set Screw against the Body Casting. • Thru topping of the body casting permits extended adjustment of the threaded rod. • Can be used with Fig 89X retaining clip for seismic applications. i i I H C F l i E AT LEAST ONE I G i FULL THREAD OF ROD MUST - BE EXPOSED I _ 3/4 I D BODY \, CASTING JAM-NUT r A MSET SCREW 1' Rod Size Set Screw Max Loads■ A Size Weight ( D E F G N Top Bottom In. In. Lbs. Lbs. Lbs. In. In. In. In. In. In. 3/8 3/8 500 250 0.34 15/16 19/16 9/16 13/16 'A 1h 1/2 1/2 950 760 0.63 13/8 113/16 1/2 11/16 9/16 23A2 ■Maximum temperature of 450'F Refer to the Pipe Hanger Catalog for Additional Parts available on Anvil's Web Site www.anvilinti.com Anvil®Pipe Hangers &Supports wtAtmanvilstar.cOm Z �NV��•- REV.05.23.06-007 ProValueo , Professional Quality. Exceptional Value. Threaded Rod PV# DESCRIPTION SIZE THREADS TENSILE APPLICATION ASTM PER INCH STRENGTH(PSI) PV35592 ALL THREAD ROD ZINC 1/4 x 6 20 60,000 INT /EXT A307-03 PV35593 ALL THREAD ROD ZINC 1/4 x 10 20 60,000 INT /EXT A307-03 PV35594 ALL THREAD ROD ZINC 3/8 x 6 16 60,000 INT /EXT A307-03 PV35595 ALL THREAD ROD ZINC 3/8 x 10 16 60,000 INT /EXT A307-03 PV35596 ALL THREAD ROD ZINC 3/8 x 12 16 60,000 INT /EXT A307-03 PV35597 ALL THREAD ROD ZINC 1/2 x 6 13 60,000 INT / EXT A307-03 PV35598 ALL THREAD ROD ZINC 1/2 x 10 13 60,000 INT /EXT A307-03 PV35600 ALL THREAD ROD ZINC 5/8 x 6 11 60,000 INT /EXT A307-03 PV35601 ALL THREAD ROD ZINC 5/8 x 10 11 60,000 INT /EXT A307-03 PV35602 ALL THREAD ROD ZINC 3/4 x 6 10 60,000 INT /EXT A307-03 PV35603 ALL THREAD ROD ZINC 3/4 x 12 10 60,000 INT /EXT A307-03 PV35604 ALL THREAD ROD STNLS 1/4 x 10 20 60,000 INT /EXT N /A PV35605 ALL THREAD ROD STNLS 3/8 x 10 16 60,000 INT / EXT N /A PV35606 ALL THREAD ROD STNLS 1/2 x 10 13 60,000 INT /EXT N /A PV35607 ALL THREAD ROD STNLS 3/4 x 6 10 60,000 INT / EXT N /A PV35608 ALL THREAD ROD PLAIN 3/8 x 6 16 60,000 INT A307-03 PV35609 ALL THREAD ROD PLAIN 3/8 x 10 16 60,000 INT A307-03 PV35610 ALL THREAD ROD PLAIN 3/4 x 6 10 60,000 INT A307-03 PV35611 ALL THREAD ROD PLAIN 3/4 x 12 10 60,000 INT A307-03 PV35612 ALL THREAD ROD STAINLESS 1/4 x 6 20 60,000 INT / EXT N /A PV35613 ALL THREAD ROD STAINLESS 3/8 x 6 16 60,000 INT /EXT N /A PV35614 ALL THREAD ROD STAI NLESS 1/2 x 6 13 60,000 INT / EXT N /A PV35615 ALL THREAD ROD STAINLESS 5/8 x 6 11 60,000 INT /EXT N /A PV35616 ALL THREAD ROD STAINLESS 5/8 x 10 11 60,000 INT / EXT N /A PV35617 ALL THREAD ROD STAINLESS 3/4 x 10 10 60,000 INT /EXT N /A PV35636 ALL THREAD ROD PLAIN 1/2 x 10 13 60,000 INT A307-03 PV35637 ALL THREAD ROD PLAIN 5/8 x 10 11 60,000 INT A307-03 Pro&hm Orlando,FL32805 RevisionmqTDLCO' wvvw.tolco.com 11 Fig. 200 - "Trimline" Adjustable Band Hanger C&USUITIO Size Range— 1/2" thru 8" pipe FM Material — Carbon Steel, Mil. Galvanized to G90 specifications Function — For fire sprinkler and other general piping purposes. Knurled swivel nut design permits hanger adjustment after installation. a Features— • (1/2" thru 2") Flared edges ease installation for all pipe types and protect CPVC plastic pipe from abrasion. Captured design keeps adjusting nut ! from separating with hanger. Hanger is easily ', B B installed around pipe. A • (21/2" thru 8") Spring tension on nut holds it A ( / securely in hanger before installation. Adjusting 11 nut is easily removed. Approvals— Underwriters' Laboratories listed (1/2" thru 8") in the USA (UL) and Canada (cUL) for steel r �- �' and CPVC plastic pipe and Factory Mutual Engineering 112 THRU 2 INCH PIPE 2 1J2 THRU 8 INCH PIPE�y Approved (3/4 thru 8"). Conforms to Federal Specifications WW-H-171 E,Type 10 and Manufacturers Standardization Society SP-69,Type 10. Maximum Temperature—650OF Finish — Mil. Galvanized. For Stainless Steel materi- als, order TOLCOO Fig. 200WON. Order By— Figure number and pipe size t /1 Dimensions •Weights Pipe Rod Size Max. Rec. Approx. Size Inch Metric A B Load Lbs. Wt./100 1/2 3/8 8mm or 10mm 31/8 25/8 400 11 3/4 3/8 8mm or 10mm 31/8 21/2 400 11 1 3/8 8mm or 10mm 33/8 25/8 400 12 1114 3/8 8mm or 10mm 33/4 27/8 400 13 11/2 3/8 8mm or 10mm 37/s 27/s 400 14 2 3/8 8mm or 10mm 41/2 3 400 15 21/2 3/8 10mm 55/8 41/8 600 27 3 3/8 10mm 57/8 4 600 29 31/2 3/8 10mm 73/8 51/4 600 34 4 3/8 10mm 73/8 5 1000 35 5 1/2 12mm 91/8 61/4 1250 66 6 1/2 12mm 101/8 63/4 1250 73 8 1/2 12mm 131/s 83/4 1250 136 OFFICE/MANUFACTURING FACILITY•1375 SAMPSON AVE.•CORONA,CA 92879•PH: 951.737.5599•FAX: 951.737.0330 CUSTOMER SERVICE•800.786.5266 www.tolco.com 't CO Fire Suppression y & Building Products Technical Services 800-381-9312 1+1-401-781-8220 www.tyco-fire.com Series TY-FRB — 2.8, 4.2, 5.6, and 8.0 K-Factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Corrosion-resistant coatings, where_ applicable, are utilized to extend the -s- .on Descript► life of copper alloy sprinklers beyond j�� that which would otherwise be obtained The TYCO Series TY-FRB,2.8,4.2,5.6, when exposed to corrosive atmo- spheres.Although corrosion-resistant !•• `""' ` anp 8.0 K-factor, Upright and Pendent p g pl�,„ Sprinklers described in this data sheet coated sprinklers have passed the I , are quick response,standard coverage, standard corrosion tests of the appli- q p g cable approval agencies,the testing is �' decorative 3 mm glass bulb-type spray pp g g ' sprinklers designed for use in light or not representative of all possible cor- � = -_ p g g rosive atmospheres. Consequently, ordinary hazard,commercial occupan- p cies such as banks, hotels, and shop- it is recommended that the end user ping malls. be consulted with respect to the suit- ability of these coatings for any given The recessed version of the Series TY- corrosive environment. The effects of FRB Pendent Sprinkler,where applica- ambient temperature,concentration of 0 ble, is intended for use in areas with a chemicals, and gas/chemical velocity, finished ceiling.This recessed pendent should be considered, as a minimum, sprinkler uses one of the following, along with the corrosive nature of the W - • A two-piece Style 10 (1/2 inch NPT) chemical to which the sprinklers will be or Style 40 (3/4 inch NPT) Recessed exposed. 0. Escutcheon with 1/2 inch(12,7 mm)of An intermediate level of the Series TY- �„; I recessed adjustment or up to 3/4 inch FRB Pendent Sprinklers is detailed \ '` r (19,1 mm)of total adjustment from the in Technical Data Sheet TFP356, and flush pendent position,or a Sprinkler Guards are detailed in Tech- - ' =- • A two-piece Style 20 (1/2 inch NPT) nical Data Sheet TFP780. or Style 30 (3/4.inch NPT) Recessed Escutcheon with 1/4 inch(6,4 mm)of recessed adjustment or up to 1/2 inch The Series TY-FRB Concealed Pendent Model/Sprinkler (12,7 mm)of total adjustment from the Sprinklers described herein must be flush pendent position. installed and maintained in compliance Identification The adjustment provided by the with this document and with the appli- Number (SIN) Recessed Escutcheon reduces the cable standards of the National Fire accuracy to which the fixed pipe drops Protection Association, in addition to to the sprinklers must be cut. the standards of any authorities having TY1131: Upright 2.8K,1/2-NPT jurisdiction. Failure to do so may impair TY1231: Pendent 2.8K, 1/2"NPT the performance of these devices. TY2131: Upright 4.2K, 1/2""NPT Owners are responsible for maintaining TY2231: Pendent 4.2K,1/2"NPT their fire protection system and devices TY3131: Upright 5.6K,1/2-NPT in proper operating condition. The TY3231: Pendent 5.6K,1/2"NPT IMPORTANT installing contractor or sprinkler manu- TY4131: Upright 8.OK, 3/4-NPT Always refer to Technical Data facturer should be contacted with any TY4231: Pendent 8.OK, 3/4-NPT Sheet TFP700 for the "INSTALLER questions. TY4831: Upright* 8.OK,1/2-NPT WARNING' that provides cautions TY4931: Pendent* 8.OK, 1/2-NPT with respect to handling and installation of sprinkler systems and components. Improper handling and installation can permanently damage a sprinkler system or its components and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. -Eastern Hemisphere Sales Only Page 1 of 10 JULY 2010 TFP171 TFP171 Page 2 of 10 7/16"(11,1 mm) ESCUTCHEON STYLE 10 or 20 SSU* NOMINAL 1/2" PLATE SEATING RECESSED DEFLECTOR MAKE-IN NPT SURFACE ESCUTCHEON 5 7/16"rn 2-1/4" 4 (11,1 mm) NOMINAL (57,2 mm) 7 2 MAKE-IN J1 3 2-3(16" 1-9/16" (55,6 mm) WRENCH Q (39,7 mm) 1 FLATS 7 11 f I 1/2" NPT SSP DEFLECTOR* 2-7/8"(73,0 mm)DIA. CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT I-Frame 3-Sealing 4-Bulb 6-Deflector Temperature rating is indicated on deflector or adjacent to 2-Button Assembly 5-Compression 7-Bushing orifice seat on frame. Screw FIGURE 1 QUICK RESPONSE SERIES TY-FRB UPRIGHT(Tyl 131)AND PENDENT(TY1231)SPRINKLERS 2.8 K-FACTOR, 112 INCH NPT 7/16"(11,1 mm) ESCUTCHEON STYLE 10 or 20 SSU* NOMINAL " PLATE SEATING RECESSED E 1/2 DEFLECTOR MAK IN -IN NPT SURFACE ESCUTCHEON 5 7/16" (11,1 mm) 2-3/16" 4 NOMINAL (55,6 mm) MAKE-IN 2 2-3/16" 1-1/2" (55,6 mm) WRENCH (38,1 mm) 3 FLATS 1 1/2"NPT SSP DEFLECTOR* 2-7/8"(73,0 mm)DIA. CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT 1 -Frame 3-Sealing 4-Bulb 6-Deflector Temperature rating is indicated on deflector or adjacent to 2-Button Assembly 5-Compression orifice seat on frame. Screw FIGURE 2 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY2131)AND PENDENT(TY2231)SPRINKLERS 4.2 K-FACTOR, 112 INCH NPT TFP171 Page 3 of 10 Y ' 7/16"(11,1 mm) ESCUTCHEON STYLE 10 or 20 SSU* NOMINAL PLATE SEATING RECESSED DEFLECTOR MAKE-IN NPT SURFACE ESCUTCHEON 6* 1 _T 5 7/16" IN (11,1 mm) 2-3/16" 4 NOMINAL (55,6 mm) MAKE-IN 2 2-3/16" 1-1/2" T(55,6 mm) WRENCH (38,1 rrm) 3 FLATS 1 1/2"NPT SSP DEFLECTOR* 2-7/8"(73,0 mm)DIA. CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT 1 -Frame 3-Sealing 4-Bulb 6-Deflector Assembly 'Temperature rating is indicated on deflector or adjacent to 2-Button y 5-Compression orifice seat on frame. Screw FIGURE 3 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY3131)AND PENDENT(TY3231)SPRINKLERS 5.6 K-FACTOR, 112 INCH NPT 1/2"(12,7 mm) ESCUTCHEON STYLE 30 or 40 SSU* NOMINAL PLATE SEATING RECESSED DEFLECTOR MAKE-IN NPT SURFACE ESCUTCHEON 5 1/2" _ 77 (12,7 mm) 2-5/16" 4 NOMINAL (58,7 mm) MAKE-IN VF 2 2-1/4" 1-9/16" (57,2 mm) L�w (39,7 mm) 3 1 � ' 3/4" NPT SSP DEFLECTOR* 2-7/8"(73,0 mm)DIA. CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT 1 -Frame 3-Sealing 4-Bulb 6-Deflector Assembly 'Temperature rating is indicated on deflector or adjacent to 2-Button 5-Compression orifice seat on frame. Screw FIGURE 4 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY4131)AND PENDENT(TY4231)SPRINKLERS 8.0 K-FACTOR,314 INCH NPT TFP171 Page 4of1O ' DEFLECTOR MAKE-IN NPT 3 FLATS CROSS 1/2"NPT DEFLECTOR SECTION UPRIGHT PENDENT 1 -Frame 3-Sealing 4-Bulb 6-Deflector Assembly Temperature rating is indicated on deflector or adjacent to 2-Button 5-Compression orifice seat on frame. Screw FIGURE 5 QUICK RESPONSE SERIES TY-FRB UPRIGHT(TY4831)AND PENDENT(TY4931)SPRINKLERS Techn�� � .��0�� �oh �6m� f��e �5�5�Cand ical n�JJ~~~ ~~�w��m� 3132/nch(2,4 bho2DO"F/14/^C ��)����� The glass Bulb contains a fluid that temperature ratings. -- ----- expands when exposed to heat.When Obta/na leak-tight //2 inch NPTyprin- &pprova|s the rated temperature is reached, the kler joint by applying u xn/ninunn to UL and C-ULListed fluid expands sufficiently to shatter the maximum torque of7to /4/t/baA9,5 FM, -PCB.and NYC Approved g|uun 8u|b, allowing the sprinkler to of torque Refer to Table Aand B for complete activate and water toflow. can distort the sprinklerInlet with con- approval information including sequent/eeAagoorimpoirmontmf&ho corrosion-resistant status. Design D � � � � K8auimummVVorWngPressure �� � " ''" attempt ��������� � RefertoT�b|eC ~ ~~~~~ ~~� ''-------`-----''' -----'—' eon Plate by under-or over-tightening Discharge Coefficient The TYCO Series TY-FRB Pendent the sprinkler. Re-adjust the position of K=2.8GPK4/pnilm 0'8LpyW/burl and Upright Sprinklers are intended the sprinkler fitting tosuit. forOepn�ecbon designed K=42GPk8 ai'� (SO5LPK8/bu� ~�~~'''~ The Series TY-FRB Pendent and ' '' ' e�oondanoewith1hoatandandinat�||a' K=5.0GpyW/pai,� (8U.OLPK8/barl� 8on rules recognized by the applicable Upright8rinNoramuutbeinate||od )n accordance with the following K=8'0GpK8/Poilo �15'2LpyN/ba� �� LiatingorApprovo|sganoy�uohoo.UL Temperature Rating Listing ia based on the mquinsnnent instructions. ' Refer to Table A and 8 NFpA18�mdFKX Approval ie based o» 1. Install Pendent sprinklers in the B. theroquimmentaofF���LoamPreven' pendent position. |nalaU upright Finishes iion Data Sheets). Only the Style 10. sprinklers`nthe upright position. Sprinkler: Refer to Table A and B. 2O'3O'or40 Recessed Escutcheon,e» 2' Withpipe-threadseo|urtapplied 0n Recessed Escutcheon:White Coatod' applicable, iatobeuuodfornecnaoed the pipe threads, hand-tighten the Chrome Plated, orBrass Plated. pendontin-taUs¢iona. sprinkler into the sprinkler fitting. Physical Characteristics ������~�/�0~������� 3� Tighten the a sprinkler into the aprin Frumo. . . . . . . . . . . . . . � � � � � Bronze ��~~~��~~~���~-~�~ h|erf|tti i onlythe Bu�on. . . . . . . . . . . . . .Bmao/Co or The TYCO Series TY-FRB Sprinklers Sprinkler Wrench (Figure 14). With Sealing Assembly. . . . . . . . .8eryUium must be installed in accordance with reference to Figures 1 through N|cke|w/TeOont the following instructions. 5 apply the VV-Typo 0 Sprinkler Bulb . . . . . . .. . . . . . . . . . . . . . .G)aas VVnanc6 to the sprinkler wrench Compression Screw. . . . . . . . Bronze flats. Deflaotor. . . . . . . . . . .Copper/Bronze Bushing .0 . . . . . . . . . . . Bronze Do not install any bulb-type the omo is macxeo or there is a ma f liquid from the bulb. With the TFP171 Page 5 of 10 SPRINKLER FINISH(See Note 5) K BULB LIQUID NATURAL CHROME WHITE*** FACTOR TYPE TEMPERATURE COLOR BRASS PLATED POLYESTER 135°F/57°C Orange PENDENT 155°F/68°C Red (TY1231) and 175°F/79°C Yellow 1,2,3,4 UPRIGHT(TY1131) 200°F/93°C Green 286°F/141°C Blue 135°F/57°C Orange 2.8 RECESSED 155°F/68°C Red 1/2"NPT PENDENT (TY1231)* 175°F/79°C Yellow Figure 6 200°F/93°C Green 135°F/57°C Orange 1,2,4 RECESSED PENDENT 155°F/68°C Red (TY1231)** 175°F/79°C Yellow Figure 7 200°F/93°C Green 135°F/57°C Orange PENDENT 155°F/68°C Red (TY2231) and 175°F/79°C Yellow UPRIGHT(TY2131) 200°F/93°C Green 286°F/141°C Blue 135°F/57°C Orange 4.2 RECESSED 1/2"NPT PENDENT 155°F/68°C Red 1,2 (TY2231)* 175°F/79°C Yellow Figure 8 200°F/93°C Green 135°F/57°C Orange RECESSED PENDENT 155°F/68°C Red (TY2231)** 175°F/79°C Yellow Figure 9 200°F/93°C Green NOTES: 1. Listed by Underwriters Laboratories,Inc.,(UL)as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories,Inc.,for use in Canada(C-UL)as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation(FM)as Quick Response Sprinklers. 4. Approved by the City of New York under MEA 354-01-E. 5. Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers. * Installed with Style 10(1/2"NPT)or Style 40(3/4"NPT)3/4"Total Adjustment Recessed Escutcheon,as applicable. Installed with Style 20(1/2"NPT)or Style 30(3/4"NPT)1/2"Total Adjustment Recessed Escutcheon,as applicable. '**Frame and Deflector only.Listings and approvals apply to color(Special Order). N/A:Not Available TABLE A LABORATORY LISTINGS AND APPROVALS FOR 2.8 AND 4.2 K-FACTOR SPRINKLERS TFP171 Page 6 of 10 SPRINKLER FINISH(See Note 8) K TYPE TEMPERATURE BULB LIQUID NATURAL CHROME I WHITE*** LEAD FACTOR COLOR BRASS PLATED POLYESTER COATED 135°F/57°C Orange PENDENT(TY3231) 155°F/68°C Red and 175°F/79°C Yellow 1,2,3,4,5,6,7 1,2,3,5 UPRIGHT 200°F/93°C Green (TY3131) 286°F/141°C Blue 135°F/57°C Orange RECESSED 155°F/68°C Red 5.6 PENDENT 1/2"NPT (TY3231)* 175°F/79°C Yellow 1,2,4,5 N/A Figure 10 200°F/93°C Green 286°F/141°C Blue 135°F/57°C Orange RECESSED 155°F/68°C Red PENDENT (TY3231)** 175°F/79°C Yellow 1,2,3,4,5 N/A Figure 11 200°F/93°C Green 286°F/141°C Blue 135°F/57°C Orange PENDENT(TY4231) 155°F/68°C Red and 175°F/79°C Yellow 1,2,3,4,5,6,7 1,2,5 UPRIGHT 200°F/93°C Green (TY4131) 286°F/141°C Blue 135°F/57°C Orange RECESSED 155°F/68°C Red 8.0 PENDENT 3/4"NPT (TY4231)* 175°F/79°C Yellow 1,2,5 N/A Figure 12 200°F/93°C Green 286°F/141°C Blue 135°F/57°C Orange RECESSED 155°F/68°C Red PENDENT(TY4231)** 175°F/79°C Yellow 1,2,3,5 N/A Figure 13 200°F/93°C Green 286°F/141°C Blue 135°F/57°C Orange 8.0 PENDENT(TY4931) 155°F/68°C Red 1/2"NPT and 175°F/79°C Yellow 1,2,4,5,6 1,2,5 UPRIGHT 200°F/93°C Green (TY4831) 286°F/141°C Blue NOTES: 1. Listed by Underwriters Laboratories,Inc.,(UL)as Quick Response Sprinklers. 2. Listed by Underwriters Laboratories,Inc.,for use in Canada(C-UL)as Quick Response Sprinklers. 3. Approved by Factory Mutual Research Corporation(FM)as Quick Response Sprinklers. 4. Approved by the Loss Prevention Certification Board(LPCB Ref.No.007k/04)as Quick Response Sprinklers.However,LPCB does not rate the thermal sensitivity of recessed sprinklers. 5. Approved by the City of New York under MEA 354-01-E. 6. VdS Approved(For details,contact Tyco Fire Suppression&Building Products,Enschede,Netherlands,Tel.31-53-428-4444/Fax 31-53-428-3377.) 7. Approved by the Loss Prevention Certification Board(LPCB Ref.No.094a/06)as Quick Response Sprinklers. 8. Where Polyester Coated and Lead-Coated Sprinklers are noted to be UL and C-UL Listed,the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers.Where Lead-Coated Sprinklers are noted to be FM Approved,the sprinklers are FM Approved as a Corrosion-Resistant Sprinklers. *Installed with Style 10(1/2"NPT)or Style 40(3/4"NPT)3/4"Total Adjustment Recessed Escutcheon,as applicable. *'Installed with Style 20(1/2"NPT)or Style 30(3/4"NPT)1/2"Total Adjustment Recessed Escutcheon,as applicable. ***Frame and Deflector only.Listings and approvals apply to color(Special Order). N/A:Not Available TABLE B LABORATORY LISTINGS AND APPROVALS FOR 5.6 AND 8.0 K-FACTOR SPRINKLERS TFP171 Page 7 of 10 SPRINKLER FINISH K TYPE NATURAL CHROME WHITE LEAD FACTOR BRASS PLATED POLYESTER COATED PENDENT(TY1231) and UPRIGHT(TY1131) 2.8 175 PSI(12,1 BAR) N/A 1/2"NPT RECESSED PENDENT(TY1231) PENDENT(TY2231) and 4.2 UPRIGHT(TY2131) 1/2"NPT 175 PSI(12,1 BAR) N/A RECESSED PENDENT(TY2231) PENDENT(TY3231) 175 PSI and UPRIGHT(TY3131) 250 PSI(17,2 BAR) (12,1 BAR) 5.6 OR 175 PSI(12,1 BAR) 1/2"NPT (SEE NOTE 1) RECESSED N/A PENDENT(TY3231) PENDENT(TY4231) 175 PSI and (12,1 BAR) 8.0 UPRIGHT(TY4131) 3/4"NPT 175 PSI(12,1 BAR) RECESSED N/A PENDENT(TY4231) 8.0 PENDENT(TY4931) 175 PSI 1/2"NPT and UPRIGHT(TY4831) 175 PSI(12,1 BAR) (12,1 BAR) NOTES: 1. The maximum working pressure of 250 psi(17,2 bar)only applies to the Listing by Underwriters Laboratories Inc.(UL);the Listing by Underwriters Laboratories,Inc.for use in Canada(C-UL);and,the Approval by the City of New York. TABLE C MAXIMUM WORKING PRESSURE The Series TY-FRB Recessed Pendent Care and Exercise care to avoid damage to Sprinklers must be installed in accor- sprinklers before, during, and after dance with the following instructions. Maintenance installation. Never paint, plate, coat, 1. After installing the Style 10, 20, 30, or otherwise alter automatic sprinklers or 40 Mounting Plate, as applica- The TYCO Series TY-FRB must be after they leave the factory. ble, over the sprinkler threads and maintained and serviced in accordance Replace sprinklers that: with pipe-thread sealant applied to with the following instructions. . were modified or over-heated. the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. ,® • were damaged by dropping,striking, wrench twisting,wrench slippage,or 2. Tighten the sprinkler into the sprin- Before closing a fire protection system the like. kler fitting using only the W Type 7 main control valve for maintenance . are leaking or exhibitingvisible signs Recessed Sprinkler Wrench (Fig- work on the fire protection system of corrosion. g ure 15). With reference to Figures 1 that it controls, obtain permission to to 4, apply the W Type 7 Recessed shut down the affected fire protection • were exposed to corrosive products Sprinkler Wrench to the sprinkler systems from the proper authorities of combustion but have not oper- wrench flats. and notify all personnel who may be ated, if you cannot easily remove 3. After ceiling installation and finish- affected by this action. combustion by-products with a cloth. ing, slide on the Style 10, 20,30, or Absence of the outer piece of an • have a cracked bulb or have lost liq- 40 Closure over the Series TY-FRB escutcheon, which is used to cover uid from the bulb. Refer to the Instal- Sprinkler and push the Closure over a clearance hole, can delay sprinkler lation section in this data sheet. the Mounting Plate until its flange operation in a fire situation. comes in contact with the ceiling. TFP171 Page 8 of 10 a 2-7/8" DIA. 2-7/8"DIA. (73,0 mm) " 19,1 mm (73,0 mm 5/8±1/4" 3/4 ( ) 1/2±1/8" ) 1/2"(12,7 mm) (15,9±6,4 mm) 2-1/4" DIA. 1/4"(6,4 mm) (12,7±3,2 mm) 2-1/4"DIA. 1/4"(6,4 mm) FACE OF (57,2 mm) 2 mm),(57 MOUNTING FACE OF MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING 1/8" 1/8" (3,2 mm) (3,2 mm) 74 MOUNTING MOUNTING SURFACE SURFACE CLOSURE SERIES 1-5/16"(33,3 mm) CLOSURE SERIES 1-5/16"(33,3 mm) TY-FRB 13/16"(20,6 mm) TY-FRB 1-1/16"(27,0 mm) FIGURE 6 FIGURE 7 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 314 INCH TOTAL ADJUSTMENT WITH TWO-PIECE 112 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON 2.8 K-FACTOR, 112 INCH NPT 2.8 K-FACTOR, 112 INCH NPT 2-7/8"DIA. 2-7/8"DIA. 5/8±1/4" (73,0 mm) 3/4"(19,1 mm) (73,0 mm) 1/2-El/8" (73,0 (12,7 mm) (15,9±6,4 mm) 2-1/4" DIA. 1/4"(6,4 mm) (12,7±3,2 mm) 2-1/4"DIA. 1/4"(6,4 mm) FACE OF (57,2 mm) 2 mm),(57 MOUNTING FACE OF MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING 1/8" 1/8" L T I — I (3,2 mm) (3,2 mm) MOUNTING MOUNTING SURFACE SURFACE CLOSURE SERIES 1-1/4"(31,8 mm) CLOSURE SERIES 1-1/4"(31,8 mm) TY-FRB 3/4"(19,1 mm) TY-FRB 1"(25,4 mm) FIGURE 8 FIGURE 9 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 3141NCH TOTAL ADJUSTMENT WITH TWO-PIECE 112 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON 4.2 K-FACTOR, 112 INCH NPT 4.2 K-FACTOR, 112 INCH NPT Initial and frequent visual inspections of Responsibility lies with the owner for Care must be exercised to avoid dam- random samples are recommended for the inspection, testing, and mainte- age to the sprinklers -before, during, corrosion-resistant sprinklers to verify nance of their fire protection system and after installation. Sprinklers dam- the integrity of the corrosion-resistant and devices in compliance with this aged by dropping, striking, wrench material of construction. Thereafter, document, as well as with the appli- twist/slippage, or the like, must be annual inspections per NFPA 25 should cable standards of the National Fire replaced. Also, replace any sprinkler suffice. Protection Association (for example, that has a cracked bulb or that has lost Inspections of corrosion-resistant NFPA 25), in addition to the standards liquid from its bulb. (Ref. Installation sprinklers are recommended at close of any other authorities having jurisdic- Section). range, instead of from the floor level tion.Contact the installing contractor or Initial and frequent visual inspections of per NFPA. Inspection at close range sprinkler manufacturer regarding any random samples are recommended for can better determine the exact sprin- questions. corrosion-resistant sprinklers to verify kler condition and the long-term integ- Automatic sprinkler systems are rec- the integrity of the corrosion-resistant rity of the corrosion-resistant material, ommended to be inspected, tested, material of construction. Thereafter, which can be affected by the corrosive and maintained by a qualified Inspec- annual inspections per NFPA 25 should conditions present. tion Service in accordance with local suffice. requirements and/or national codes. TFP171 Page 9 of 10 y 2-7/8"DIA. 2-7/8" DIA. 5/8±1/4" (73,0 mm) 3/4"(19,1 mm) (73,0 mm) 1/2" 12,7 mm (15,9±6,4 mm) 2-1/4"DIA. 1/4"(6,4 mm) (12,7±3,2 mm) 2-1/4"DIA. 1/4"(6,4 mm) FACE OF (57,2 mm) MOUNTING FACE OF (57,2 mm) / MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING 1/8" (3,2 mm) (3,2 mm) MOUNTING MOUNTING SURFACE SURFACE CLOSURE SERIES 1-1/4"(31,8 mm) CLOSURE SERIES 1-1/4"(31,8 mm) TY-FRB 3/4"(19,1 mm) TY-FRB 1"(25,4 mm) FIGURE 10 FIGURE 11 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 314 INCH TOTAL ADJUSTMENT WITH TWO-PIECE 112 INCH TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON STYLE 20 RECESSED ESCUTCHEON 5.6 K-FACTOR, 112 INCH NPT 5.6 K-FACTOR, 112 INCH NPT 2-7/8"DIA. 2-7/8"DIA. 5/8±1/4" (73,0 mm) 3/4"(19,1 mm) 1/2±1/8" (73,0 mm) 1/2"(12,7 mm) (15,9±6,4 mm) 2-1/4"DIA. 1/4"(6,4 mm) (12,7±3,2 mm) 2-1/4"DIA. 1/4"(6,4 mm) FACE OF (57,2 mm) MOUNTING FACE OF (57,2 mm) MOUNTING SPRINKLER PLATE SPRINKLER PLATE FITTING FITTING 1/8" (3,2 mm) (3,2 mm) MOUNTING MOUNTING SURFACE SURFACE CLOSURE SERIES 1-5/16"(33,3 mm) CLOSURE SERIES 1-5/16"(33,3 mm) TY-FRB 13/16"(20,6 mm) TY-FRB 1-1/16"(27,0 mm) FIGURE 12 FIGURE 13 SERIES TY-FRB RECESSED PENDENT SERIES TY-FRB RECESSED PENDENT WITH TWO-PIECE 314 INCH TOTAL ADJUSTMENT WITH TWO-PIECE 112 INCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON STYLE 30 RECESSED ESCUTCHEON 8.0 K-FACTOR, 314 INCH NPT 8.0 K-FACTOR,314 INCH NPT Inspections of corrosion-resistant sprinklers are recommended at close WRENCH range, instead of from the floor level RECESS per NFPA. Inspection at close range / WRENCH RECESS can better determine the exact sprin- (END"A" USED FOR kler condition and the long-term integ- 1/2" NPT MODELS) rity of the corrosion-resistant material, which can be affected by the corrosive conditions present. WRENCH RECESS (END"B" USED FOR 3/4" NPT MODELS) PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA FIGURE 14 W-TYPE 6 SPRINKLER FIGURE 15 WRENCH W-TYPE 7 RECESSED SPRINKLER WRENCH TFP171 ` Page 10 of 10 P/N 57 - XXX - X - XXX MODEL/SIN SPRINKLER TEMPERATURE FINISH RATINGS 330 2.8K UPRIGHT(1/2"NPT) TY1131 1 NATURAL BRASS 135 135°F(57°C) 331 2.8K PENDENT(1/2"NPT) TY1231 4 WHITE POLYESTER 155 155°F(68°C) 340 4.2K UPRIGHT(1/2"NPT) TY2131 3 WHITE(RAL9010)- 175 175°F(79°C) 341 4.2K PENDENT(1/2"NPT) TY2231 9 CHROME PLATED 200 200°F(93°C) 370 5.6K UPRIGHT(1/2"NPT) TY3131 7 LEAD COATED 286 286°F(141-C) 371 5.6K PENDENT(1/2"NPT) TY3231 390 8.OK UPRIGHT(3/4"NPT) TY4131 391 8.OK PENDENT(3/4"NPT) TY4231 360 8.OK UPRIGHT(1/2"NPT) TY4831" Eastern Hemisphere sales only. 361 8.OK PENDENT(1/2"NPT) TY4931' TABLE D PART NUMBER SELECTION SERIES TY-FRB PENDENT AND UPRIGHT SPRINKLERS Limited responsible for sprinkler system design Ordering errors or inaccurate or incomplete infor- g Warrant r supplied by Buyer or Buyer's procedure Y representatives. Products manufactured by Tyco Fire In no event shall TFSBP be liable, in Contact your local distributor for Suppression & Building Products contract, tort, strict liability or under availability. When placing an order, (TFSBP) are warranted solely to the any other legal theory, for incidental, indicate the full product name and Part original Buyer for ten(10)years against indirect,special or consequential dam- Number(P/N). defects in material and workmanship ages, including but not limited to labor when paid for and properly installed charges, regardless of whether TFSBP Sprinkler Assemblies with NPT and maintained under normal use and was informed about the possibility of service. This warranty will expire ten such damages, and in no event shall Thread Connections (10) years from date of shipment by TFSBP's liability exceed an amount Specify: (Specify Model/SIN), Quick TFSBP. No warranty is given for prod- Response, (specify K-factor), (specify equal to the sales price. temperature ratin ucts or components manufactured by p g), Series TY-FRB companies not affiliated by ownership The foregoing warranty is made in lieu (specify Pendent or Upright) Sprinkler with TFSBP or for products and com- of any and all other warranties,express with(specify type of finish or coating), ponents which have been subject to or implied.including warranties of mer- P/N (specify from Table D). misuse, improper installation, corro- chantability and fitness for a particular Recessed Escutcheon: sion,or which have not been installed, purpose. Specify: Style (10, 20, 30, or 40) maintained, modified or repaired in This limited warranty sets forth the Recessed Escutcheon with (specify`) accordance with applicable Standards exclusive remedy for claims based on finish, P/N (specify'). of the National Fire Protection Associa- failure of or defect in products, materi- tion, and/or the standards of any other als or components,whether the claim is Sprinkler Wrench Authorities Having Jurisdiction. Mate- made in contract,tort,strict liability or Specify: W-Type 6 Sprinkler Wrench, rials found by TFSBP to be defective any other legal theory. P/N 56-000-6-387. shall be either repaired or replaced, at TFSBP's sole option. TFSBP neither This warranty will apply to the full Specify: W-Type 7 Sprinkler Wrench, assumes, nor authorizes any person extent permitted by law.The invalidity, P/N 56-850-4-001. to assume for it,any other obligation in in whole or part, of any portion of this Refer to Technical Data Sheet TFP770. connection with the sale of products or warranty will not affect the remainder. parts of products.TFSBP shall not be Copyright©2007-2010 Tyco Fire Suppression&Building Products.All rights reserved.