Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
18-20317
CITY OF ZEPHYRHILLS 5335 - 8TH STREET (813) 780-0020 20317 EMERGENCY GENERATOR PERMIT PERMIT INFORMATION LOCATION INFORMATION Permit Number: 20317 Address: 5410 SATSUMA DR Permit Type: FIRE EMERG GENERATOR<30K ZEPHYRHILLS, FL. Class of Work: FIRE-EMERGENCY GENERATOR Township: Range: Book: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Square Feet: Subdivision: ZEPHYR HEIGHTS Est. Value: Parcel Number: 12-26-21-0040-00200-080 Improv. Cost: 8,500.00 OWNER INFORMATION Date Issued: 10/05/2018 Name: COLANDRIA, LOUIS JR & DARLENE Total Fees: 100.00 Address: 5410 SATSUMA DR Amount Paid: 100.00 ZEPHYRHILLS, FL. 33542 Date Paid: 10/05/2018 Phone: (813)715-4398 Work Desc: INSTALLATION GENERATOR SYSTEM W/ ELECTRIC & SLAB CONTRACTORS APPLICATION FEES DAVES HOME HELPER SVC I C FIRE PERMIT FEES 100.00 FIRE INSTALLATION-Final Ins ections Re uired ELECTRICAL FINAL FINAL Chapter 633, Florida Statutes,authorizes the City to charge and collect user fees to pay for the costs of fire prevention and protection related activities such as inspections, plan review, administrative fees, and other costs related to the aforementioned. Complete Plans, Specifications and Fee Must Accompany Application. Commencement of work without written approval of the Fire Department's Fire Marshal or required permits or opening up for commercial activity without an approved final inspection shall be charged double permit fee per day of operation or a minimum of$100.00, whichever is greater. All work shall:be performed in accordance with City Codes and Ordinances. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT." CONTRA ORS NATURE PERMIT OFFICER IT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED ZEPHYRHILLS FIRE RESCUE - 813-780-0041 813-780-0020 City of Zephyrhills Permit Application FaX-813-780-0021 e7 Building Department g; n n Date Received `— phone Contact for Permitting , e -[0Q 40 ,I A—D 1—rr L ^ Owner's Name u C� t umbe Owner Phone Number Owner's Address J 4J 10 U --o . Owner Phone Number Fee Simple Titleholder Name I Owner Phone Number Fee Simple titleholder Address JOB ADDRESS ��IO �Su' ��, �g //�� ^^nnLOT# SUBDIVISION PARCEL ID# W-0 —QJJ —0000U Q (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEW CONSTR ADD/ALT = SIGN 0 0 DEMOLISH INSTALL e REPAIR PROPOSED USE = SFR 0 COMM = OTHER TYPE OF CONSTRUCTION = BLOCK 0 FRAME = STEEL DESCRIPTION OF WORK T,— '�J! BUILDING SIZE I I SO FOOTAGE= HEIGHT =BUILDING $ VALUATION OF TOTAL CONSTRUCTION LECTRICAL $ T50,0 S0Q AMP SERVICE = PROGRESS ENERGY = W.R.E.C. =PLUMBING $ -ff- r 0163` =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION1v I —� =GAS = ROOFING = SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO r BUILDER COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN 11YIN Address Lic'e1nsse# c_ ECLTRICIQr COMPANY IS l'�f7bC+ 2,� V�CY IGNATURE REGISTERED Y/ N 1, FEE CURREN /N , Address ' Ot�"1 05 �n C,L of ZN} License# e—%300')00 o PLUMBER COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address License# MECHANICAL COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN L11 N Address License# OTHER COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address License# I I I I I I I I I I I I I I I I I I I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stonnwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster,Site Work Permit for subdivisionsilarge projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. PROPERTY SURVEY SURVEY required for all NEW construction. Di racoons: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500) " Agent(for the contractor)or Power of Attomey(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work,they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the"contractor Block"of this application for which they will be responsible. If you, as the owner sign as the contractor,that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACTIUTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use in existing buildings, or expansion of existing buildings,as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands,that such fees, as may be due,will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a"certificate of occupancy"or final power release. If the project does not involve a certificate of occupancy or final power release,the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended): If valuation of work is$2,500.00 or more,I certify that I, the applicant, have been provided With a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner",I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner"prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction,zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work,and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands,Water/WastewaterTreatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls,Docks,Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone"V"unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume"will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone"A" in connection with a permitted building using stem wall construction,I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties,the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one(1) acre which are elevated by fill,an engineered drainage plan is required. If I am the AGENT FOR THE OWNER,I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate,cancel,alter,or set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans,construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance,or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced. An extension may be requested, in writing,from the Building Official for a period not to exceed ninety(90)days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTFJIJD TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER4WAN 8ZORNEY BEFORE RECORDING YOU OTIC OF COMMENC MENT. FLORIDA JURAT J OWNER ORAGEN r CONTRACTO 4—� 1 b d bswo to or a� e ` Subscribed and sworn (or affTm )before methis l�y by_ Q l) 1 Who is/are personally known to me or h wave produced Who r fare p1l: ally known me or has/have produced a 'd n'fica ion. as identification. Notary Public Notary Public Corn is on No. Commission No. 1 0 1 yth Name of Notary typ antedN e of Notary typed,printed ra[tTr1� 2. MY COMMISSION#GG139203 SAY PV MARIA MAE SANTOS _ y— ' T' Notary Public-State of Florida BondedPhroughls State?n0surance .._,j v°•' Commission#GG 65127 My Comm.Expires Jan 23,20 11 Mpg C2 co REVIEW DATELZ� CITY OF ZEPHYRHILLS FIRE AND LIFE SAFETY EXAMINERe-<� ALL WORK SHALL COMPLY WITH NFFA CODES AND STANDARDS GENERAC ©.S om�e� �jPer I DAVE'S HOME HELPER 40415 Chancey Rd. Suite104 Zypherhills,FL 33542 (813)991-7569 www.daveshomehelper.com Sizing Report Rated Nominal Voltage 240 Generator Fuel Choice Propane Sizing Method(NEC 220) Part IV (Part III required for selected circuit implementation,Both valid for whole house) General Lighting&Receptacles Load(kW) Square Footage Being Covered(ftA2) 1150 3.45 Small Appliance Circuits(20 amps) Kitchen Circuits 2 3 Laundry Circuits 1 1.5 Managed Estimated Nameplate Fixed-In-Place Appliances&Motors Loads (kW) (amps) 240 V Load(kW) Dryer 5.5 X 5.5 Range-Oven w/Top 8.5 X 8.5 Water Heater 5.0 X 5.0 Dishwasher 1.5 1.5 Refrigerator 0.8 0.8 Managed Estimated Nameplate Air Conditioning&Cooling Loads (kW) (amps) 240 V Load(kW) 3.0 Ton Unit 3.0 X 3.0 Managed Estimated Nameplate Heating&Heat Pumps Loads (kW) (amps) 240 V Load(kW) Heat Pump(3 Ton) 3.0 X 3.0 Estimated Actual Utilized Transient Requirement (LRA) (LRA) (LRA) Largest Motor's Starting Amps(LRA) 86 0 86 Load NEC Summary NEC Load (kW) Required General Lighting&Receptacles 8 Fixed-in-Place Appliances&Motors 21.3 Sum of all General Loads 29.3 17.7 Cooling 3 3 Heating(w/demand factors) 3 3 Larger of Heating&Cooling 3 3 Sizing based on requirements of NEC Article 220,Part IV 20.7 Elevation 0 ft Minimum size generator for motor starting requirements 11 BTU load required 350000 22 kW Generac Model Generator Recommended (0j" ENERAC 0 16/20/22 kW GUARDIANO SERIES Residential Standby Generators Air-Cooled Gas Engine INCLUDES: ID True Power"' Electrical Technology Standby Power Rating 171-- �.Ajodels G100-10,36-0. G�)07 Q) Two Line LCD Multilingual Digital .03. -i(3-lik-A/150 Fitz Evolution"' Controller(English/Spanish/ i%:iodel G007035-0 SiSCiLle)- 1(3 k1h!60 111- French/Portuguese) I-Alodels f"007 3,09-0.G007038-0 Bis ue; 20 kkAj SCE':Z -Biscl"_!e) -fl��ililodels G00700.C1 '-10070A 9-1 0-,Iun--.in1-,lrr, M i"i 60 H,-, Two Transfer Switch Options Available: 100 Amp, 16 Circuit Switch or 200 Amp Service Rated Smart Switch. .- !-,--! See Page 4 for Details. —0, * Electronic Governor * System Status&Maintenance Interval LED Indicators ENERAC' * Sound Attenuated Enclosure * Flexible Fuel Line Connector * Direct-To-Dirt Composite Mounting Pad * Natural Gas or LP Gas Operation QUIFHEST LISTED (0 5 Year Limited Warranty Note:GUL certification only applies to unbundled units and units packaged with lirruled circuit Witches.Units packaged Ath the Smart Switch are UL certified in 0 Capability to be installed within 18"(457 mm) the USA only. of a building* *Only if located away from doors.windows and fresh air intakes, and unless othervAse directed by local codes. FEATURES C', INNOVATIVE ENGINE DESIGN&RIGOROUS TESTING are at the heart of Generac's 0 SOLID-STATE.FREQUENCY COMPENSATED VOLTAGE REGULATION: success in providing the most reliable generators possible.Generac's G-Force engine This state-of-the-art power maximizing regulation system is standard on lineup offers added peace of mind and reliability for when you need it the most.The all Generac models.It provides optimized FAST RESPONSE to changing G-Force series engines are purpose built and designed to handle the rigors of load conditions and MAXIMUM MOTOR STARTING CAPABILITY by extended run times in high temperatures and extreme operating conditions- electronically torque-matching the surge loads to the engine.Digital voltage regulation at-1%. TRUE POWER- ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave (D SINGLE SOURCE SERVICE RESPONSE from Wuraic's exlensNe dealer form produce less than 5%Total Harmonic Distortion for urilillr quality power.This allows network provides pans and service know-how for the entire unit,from the confident operation of sensitive electronic equipment and micro-chip based appliances, engine to the smallest electronic component. such as variable speed HVAC systems. TEST CRITERIA: 0. GWERAC TRANSFER SWITCHES: Long life and reliability are PROTOTYPE TESTED NEMA MGI-22 EVALUATION synonymous with GENERAC POWER SYSTEMS. One reason for this SYSTEM TORSIONAL TESTED MOTOR STARTING ABILITY confidence is that the GENERAC product line includes its own transfer systems and controls for total system compatibility. ' IGENE R AC R - 4 -ass Mobile Elm usir:g*-Doconaknig,Pins. i y —GENE-RAC' 15/20/22 kW features and benefits ® Engine 0 GeneracG-Force design Maxirulzese>>give-brwilriug"foriucraasedtrialefficiency.Plateauhonedcylinderwallsandplasmamolyringshelpstheengine run cooler,reducing oil consumption resulting in longer engine life. @ "Spiny-lok"cast iron Cyril Ida(wjlfs Rigid construction and added durability provide long engine life. © Electronic ignition/spark advance These features combine to assure smooth,quick starting every time. Q Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance,less maintenance and longer engine life.Now featur- ing up to a 2 year/200 hour oil change interval. @ Low oil pressure shutdown systelit Shutdown protection prevents catastrophic engine damage due to lour oil. ® High temperature shutdown Prevents damage due to overheating. Generator a Revolving field Allows for a smaller,light weight unit that operates 25%more efficiently than a revolving armature generator. * Skewed stator Produces a smooth output wavelorm for compatibility with electronic equipment. ® Displaced phase excitation Maximizes motor starting capability. 83 Automatic voltage regulation Regulates the output voltage to±1%prevents damaging voltage spikes. 0 UL 2200 listed For your safety, Transfer Switch (if applicable) G Fully automatic Transfers your vital electrical loads to the energized source of power. o NEMA 3R Can be installed inside or outside for maximum flexibility. e Remote mounting Mounts near your existing distribution panel for simple,low-cost installation. Evolution" Controls © Auto/Manual/Off illuminated buttons Selects the operating mode and provides easy,at-a-glance status indication in any condition. * Two-line LCD multilingual display Provides homeowners easily visible fogs of history,maintenance and events up to 50 occurrences. (D Sealed,raised buttons Smooth,weather-resistant user interface for programming and operations. * Utility voltage sensing Constantly monitors utility voltage,selpoints 65%dropout,80%pick-up,of standard voltage. * Generator voltage sensing Constantly monitors generator voltage to ensure the cleanest power delivered to the home. * Utility interrupt delay Prevents nuisance start-ups of the engine,adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. m Engine warm-up Ensures engine is ready to assume the load,setpoint approximately 5 seconds. Engine cool-dawn Allows engine to cool prior to shutdown,setpoint approximately 1 minute. Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week.Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. ® Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM-style batteries. ® Main line circuit breaker Protects generator from overload. e Electronic governor Maintains constant GO Hz frequency. Unit o SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature,withstanding winds up to 150 mph.Hinged key locking roof panel for security_Lift-out front for easy access to all routine maintenance items.Electrostat- ically applied textured epoxy paint for added durability. e Enclosed critical grade muffler Quiet,critical grade muffler is mounted inside the unit to prevent injuries. f) Small,compact,attractive Makes for an easy,eye appealing installation,as close as 181 away from a building. Installation System 19 1 it(305 mm)flexible fuel line connoclui Absorbs any generator vibration when connected to rigid pipe. * Direct-to-dirt composite mounting pad Complex lattice design prevents settling or sinking of the generator system. e Integral sediment trap Prevents particles and moisture from entering the fuel regulator and engine,prolonging engine Iffe. • G E N RA.9,•i' 16/20/22 W specifications Generator G007035-0,G007036-0, G007038.0,G007039-0 G007042-1,GOD7043-1 Model 6007037-0(16 kW) (20 kW) (22 kW) Rated Maximum Continuous Power Capacity(LP) 1000 Watts` 20,000 Watts' 22 000 - Rated Maximum Continuous Pourer Capacity(NG) 16,000 Wags' 18,000 Watts' 19,509 Raled•Vollage 240 •240 24.0 Rated Maximum Continuous Load Current—240 Volts(LP/NG) 66.6/66.6 83.3175 91.6/81.3 Total Harmonic Distortion Less than 5% Less than 5 Less than 5% Main Line Circuit Breaker 70 Amp 100 Amp 10O Amp Phase 1 1 :1 Number of Rotor Poles 2 2 2 Rated AC Frequency 60 Hi .60 Hz-:- 60Hz Pourer Factor 1.0 1.0 1.0 Battery Requirement(not included) 12 Volts,Group 20H 540 WA-Minimutn or Group 35AGM 650 CCA M-rnimum Unit Weight(lb/kg) 406/186 448/203 466/211 Dimensions(LxW x H)in/mm 4B x 25 x 2911218 x 638 x 732 Sound output in dB(A)at 23 it(7 m)wfth generator operating at normal load" 66 66 67 Sound output in dB(A)at 23 It(7 m)with generator in Quiet-Test'"low-speed exercise mode" 58. 58 58 Exercise duration 5 min 5 min 5 min Engine Type of Engine GENERAL G-Force 1000 Series Number of Cylinders 2 2 - 2 Displacement 999 cc 999 cc 999 cc Cylinder Block Aluminum w%.Cast Iron Sleeve Valve Arrangement Overhead Valve Overhead Valve Overhead Valve Ignftion System -Solid-state w/Magneto Solid-state w/Magneto, Solid-state w/Magneto Governor System Electronic Electronic Electronic Compression Ratio 9.5:1 9.5:1-_. 9.5:1 Starter 12 Vdc 12 Vdc 12 Vdc Oil Capacity inciuding Filter Appmx 1-9 gV1.8 L Approz-1.0 gV1.B'L Approx.1.9 gV1.8 L Operating rpm 3.600 3,600 3,600' Fuel Consumption Natural Gas . f13/hr(m3/hr). 1/2 Load 218(6.17) 204(5:78) 228(6.46) Full Load 309(8.75) _ 301(8.52). 327-(9.26). Liquid Propane- fl3/hr(gai/hr)jl/nr]- _. -. 1/2 Load - 91.6(2.52)[9.53] 86(2.37)[B.99) - 92(253)[9.57] Full Load 106,8(294)[11.11] 129.6(3.56}[13:48] 142(3.90)[14.77] Note:Fuel pipe must he sized for full load.Required fuel pressure to generator fuel inlet at all load ranges-3.5-71 water column(7-13 mm mercury)for natural gas,10-12,water column(19-22 mm mercury) for LP gas.For Btu content,multiply f0/hrx 2509(LP)or ft3/hr x 1000 ING).For Megaicule content,multiply m3/hr x 93.15(LP)or m3/hrx 37.26 ING) Controls 2-Line Plaim Text MulOtingual LCO Display Simple user interface for ease of operation- Mode Bullons:Auto Aulomatic Slad on Utility failure-7 day exerciser. Manual Start with starter control,unit slays on.if utility fails•transfer to load takes place. Off Stops unit.Power-isvemoved-Control and charger still operate. Ready to RuNMaintenance Messages Standard Engine Run Hours indication Standard Programmable slant delay between 2-1500 seconds Standard(programmable by dealer only) UtilityVoifage Ldss/Relurn te_Ulrlity,Adjuslabte(BioimoutSelting) : From 140-17fV/190 216V.` Future Set Capable Fxercrser/Fxercise Set Error Warning Standard Runt/Alarm/Maintenance Lags: 50 Events Each Engine Slav(Sequence Cyclic cfanidng:16 sec on,7 rest(90 sec maximum dulalion). Starter Lack-out - Slader cannot_re-engage untfib sec after engine has stopped.: Smart Battery Charger Standard Charger Faull/Missing AC Warning Standard Low Battery/Battery Problem Protection and Battery Condition Indication Standard Automatic Voifage Regulation with Over and Under;Vallage Protection Standard : Under-Frequency/Overload/Slepper Overcurrenl Protection Standard Safety Fuserifte Problem Protection SlandaN Automatic Low Oil Pressure/High Oil Temperature Shutdown Standard Overcrank/Overspeed(@ 72 Hz)/rpm Sense Loss Shutdoim_ ` Standard: High Engine Temperature Shutdown Standard Internal FautUincorrecl Wiring Protection Standard Common External Fault Capability Standard Feld Upgradabie'mvoe Standard: '-Sound Irveis are Uen Immdw honl of the gereiator-Sound levels taiw from o:hersides of thegenefalermrybe higherdepeadatg on it stallation parameters.Rating deruddorts-Slmdby-AppOcabla imsupplying emergerc/pmserfor the durarfun of the utility poser outage.No overload mobility is available for Ibis rating.(All ratings in accordance trlh BS5514,IS03046 and U6271).'Madmum lalovoilamps and current are subject to and efruled by such faclurs as oral BhUfnegajaule contenLunblat temperature.altiNda,enginepmrerandm Trion,etc.1/ebmumrwazrdeaeasesabout3"5pacenlforeach1,e80feet(384.8metros)aboresealevel;anda6owlil decrease abrultparmni(of eachBIC(1D`F)above IBIC(fill`F). W'SNERAC" 16/20/22 kW swatch options Limited Circuits Switch Features Model G007036-0(1611W) * 16 space,24 Gircult,breakers not included. No.ofPoles 1 2 - Current Rating(Amps) 100 * Electrically operated,mechanically-hold contacts for fast,positive Voltage Rating(VAC) connections Utility Voltage Monitor(Axed)' Q) Rated for all classes of load,100%equipment rated,both inductive and -Pick-Up 80% resistive. -Dropout 65 0 2-pole,250 VAC contactors. Return hiutility` appro)L 15'sec (111 30 millisecond transfer time. Exercises bi-vieekly for 5.mi.nutes*t Standard * Dual coil design. UL Listed Standard * Rated for both copper and aluminum conductors. Total Circuits Available 24 ® Main contacts are silver plated or silver alloy to resist welding and sticking. Tandem Breaker Capabilities. 8 tandems Circuit Breaker Protected 0 NEMAIUL 3R aluminum outdoor enclosure allows for indoor or outdoor Available RMS Symmetrical 10,000 mounting flexibility. Fault Current @ 250 Volts 0 Multi listed for use with lu standard,tandem,GFCI and AFCI breakers from *Function of Evolution Controller Siemens,Murray,Eaton and Square D for the most flexible and cost effec- Exercise can be set to weekly or monthly five install. r— Dimensions W1 Height Width D wi W2 epth in 26.75 30.1 %5 13.5 6.91 —mm 679.4 764.3 266.7 343.0 175.4 Wire Ranges Conductor Lug Neutral Lug Ground Lug 110-#14 210-#14 Service Rated Smart Switch Features Model G007037-0 N)/G007039-11(29 IcW)/ 0) Includes Digital Power Management Technology standard(DPM). 6007043-0(22 kW) No.oi.poles,- 2 0 Intelligently manages up to four air conditioner loads with no additional Current Rating(Amps) 200 hardware. Voltage Raling_(VAC): 120/240"10 0 Up to four more large(240 VAC)loads can be managed when used in Utility Voltage Monitor(Axed)* -ft-t-up 80% conjunction with Smart Management Modules(SMMs). -Dropout 65% 0 Electrically operated,mechanically-held contacts for fast,Glean connections. Return to Utility' approx.13 set; 0 Hated for all classes of load,100%equipment rated,both inductive and resis- Exercises bi-vieekly for 5 minutes* Standout tive. LIL Usted standard 9 2-pole,250 VAC contactors. Enclosure I Type NEMAJUL 3R 0 SefflGe CQUIPMent fatGd,dual Goil design. Glictill NOW Ffolei;ted 22,000 * Rated for both aluminum and copper conductors. Lug Range 250 MCM-#6 * Main contacts are silver plated or silver alloy to resist welding and sticking. *Function of Evolution Controller * NEMNUL 3R aluminum outdoor enclosure allows for indoor or outdoor mount- Exercise can be set to weekly or monthly ing flexibility. -W1 Dimensions I 200 Amps 120/240,Int Open Transition Service Rated Height Width Depth Hl H2 1 t 2 6.91 mm U1 6.75 3 679.4 764.3 Ll Loam-1 1 V12 GENERAL 16/20/22 kW available accessories Model# -.Product Description The Wi-Fi enabled LP fuel level monitor provides constant monitoring of the connected LP fuel tank-Mon- G007005-0 Wi-F LP Fuel Level Monitor itoring the LP tanks fuel level is an important step in making sure your generator is ready to run during an unexpected powerfailure.Status alerts are available through a free application to notify when your LP tank is in need of a refill. Generac's Mobile Link allows you to check the status of your generator from anywhere that you have ac- , G006453-4 Mobile Link— cess to an Internet connection from a PC or with any smart device.You will even be notified via a-mail or text message when a change in the generator's status occurs-Available in the U.S_only. G005819-0 26R Wet Cell Battery Every standby generator requires a battery to startthe system.Generac offers the recommended 26R wet cell battery for use with all air-cooled standby product(excluding PowerPact®). G007101-0 Battery Pad Warmer The pad warmer rests under the battery-Recommended for use if the temperature regularly falls below 0`F. (Not necessary for use with AGM-style batteries). G007102-0 Oil Warmer Oil warmer slips directly over the oil filter.Recommended for use if the temperature regularly falls below 0°F. G005621-0 Auxiliary Transfer Switch The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load Contact Kit you may not need.Not compatible with 50 amp pre-wired switches. Fascia Base Wrap Kit The fascia base wrap snaps together around the bottom of the new air cooled generators.This offers a G007027-0-Bisque (Standard on 22 kW) sleek,contoured appearance as well as offering protection from rodents and insects by covering the lifting holes located in the base. If the generator enclosure is scratched or damaged,it is important to touch-up the paint to protect from G005703-0-Bisque Paint Kit future corrosion.The paint kit includes the necessary paint to properly maintain or touch-up a generator enclosure. G006485-0 Scheduled Maintenance Kit Generac's scheduled maintenance kits provide all the hardware necessary to perform complete routine maintenance on a Generac automatic standby generator. G006873-0 Smart Management Modules are used in conjunction with the Automatic Transfer Switch to increase its Smart Management Module(50 Amps) power management capabilities.it provides additional power management flexibility not found in any other power management system. dimensions & PCs Dimensions shorn are approximate.Refer to installation manual for exact dimensions.OD NOT USETHESE DIME14SIONS FOR INSTALLATION PURPOSES. Model UPC 1 - - - — --- _ —  �T--i _ 6007035-0 696471070354 G007036-0 696471070361 1 G007037-0 696471070378 IJI EI ! 72'2 ' G007038-0 696471070385 Roes, _ G007039-0 696471070392 ?1 G007042-0 696471070422 ----_—� - G007043-0 696471070439 w�10 --- �cr soe vrEw FRONT VIEW EN E A a Generac Power Systems,Inc. S45 W29290 HWY.59,Waukesha,WI 53189 a generac.com 5M17 Generac Pm^er Systems.Inc.Art rights reserved.AO specifications are subject to change u4thout notice-Part No.100000001 94-F SiM7 Atutomptir,Ti wisfer5witc.h From Utility ram Met Ground Building P nel (5] Meter #12 01'41 4TIAHN Control wire To 1j volt Battelij T T"f,iC� 2.N I Utility Cornmand Fraiv . 3.4 Trzins(q 210 Murn Nq ral l t1a r 4.T1 U11111ty(ornrnnnd 5,latea ISol.qtj!cll 1 5.0 or,Common it Utrals I 1 qrour 1* n )a nel panel 1 21,schadUl.L40 lco"dult from 4/)AJUM ATS to m0er 4/0 Alum 4t :r tsi 4/0 AILIM 410 Aluril One 1 1/4-1 schedule 40 conduit rrarn ATS to 100 Amp Mah 6en&ator' 20-.'2'2V'1/11 wire daqrc ZEPHYRHILLS FIRE "DEPARTMENT. 3841'0 6th AV'&Zephyrhills; FL: 33542 FIRE.SERVICE.USER FEES. increase 1/1,/2018 ' Occupancy No.: Plan No.-:: Contractor: �/T�?�-'. Business:Name: Billing.Address: Business Address:= YnGc Business.Phone=No.: Billing.Phone No.: Business-Fax No:: Billing Fax No.: Contact:. Contact:: PLAN:REVIEW:FEES. . INSPECTION FEES , PERMIT FEE _ Annual= Education,healthcare;De tention&Correctional Public• Assembly,Business' schools, . . Storage,Mercantile and. .Churches Site Plan." N/C Industrial. no charge Sprinkler. $50 . Multi-Family/commercial: ..03"sf up to 800 sq.ft $. , 24.00 . Standpipes: $50 (Minimum Charge,$24:00 801-.1,500 sq ft $ 34.52 Fire Pump .$50- :Plan Revisions DBL. 500 sq $: 60.02: Hoods , $50 9002 .$502,501-3,500 sqft $ SPRINKLER SYSTEMS - 3,501-5:000 sq ft: $ 127.52 LP Gas $50 0-25 Heads $50- 5,501-7,500 sq ft $. . :187.52 . : Natural Gas . $50 26 plus Heads. $100' " 71501-10,000 sq ft $ 262:52 . Fuel.Tanks- pertank $50 . STANDPIPE SYSTEM 10,001.15,000 sq ft $ ._375.02 Sparklers $100 Per"Rises $50 15,001,-20,000 sq ft" $ 525:02 Fire Works $500 FIRE PUMP 20,001-30,000 sq ft' $. 750.02, Camp Fire(recreation: $25 .Per Pump $100 30,00140,000 sq ft $ .1;050.02 Controlled Bum(15da; $100" " FIRE ALARM SYSTEM 40,001-60;000 sq ft $ 1,500.02 Hood/Duct---` $50:, 0-.25'Devices $50" 60,001-80,000 sq ft, $.2,100.02. Place of Assembly $50 'Annual 80,001-42,100.02)pe� 26 plus Devices $100 '. ea add 1,000sq ft $ 0.06 . . Fire Protection $25 SUPPRESSION SYSTEMS (Business closed,until Flammable Application. $50 Annuai Wet $50. violations corrected) " .. aste Tire Storage $50 Annual Dry. $50. SPRINKLER SYSTEMS Generator<;KW $1.00. . CO2 $50 Hydro.Undergrounds : $45 Generator>30'KW $100 Other $50 Hydrostatic Test :$65. " . persotem, Bio-Hazard Waste. $100:Annual KITCHEN EXHAUST_ - _Acceptance Test: $45, . .persysiem Fumigation:Tenting $50 ; Hood/Ducts' $50 Hydrant Flow $75 Torch Pot/Applied $50 " OTHER Haz.Materials. . $50 :Annual LF Installatiori per.tank" -$50 FIRE ALARM SYSTEM Fuel Tank Installation: - $50, System Acceptance $50 (Per Tank) $50 Recall Acceptance. $50 Natural Gas Installation $50; " OTHER ❑ . : (Per.Systernj Fire Wall/Smoke Wall - $15 perwaiP Spray Booth $50. LP.Gas . . " sm per tank. "Natural Gas. $26 per system Tent.1.0'x10'or.greater• $15 pertent Fire Ruittp. : $45-.. . Fire Suppression.. . : : $30 System Acceptance Exhaust Hood/Duct $30 Re-inspection DBL (other than annual) . Inspection scheduled 013E " and"cancelled less'than 24 hours Construction Insp. N/C " . . . Emergency.Vehicle Acce .$50 PLANS TOTAL INSPECTION TOTAL PERMIT TOTAL O :GRAND.TOTAL. . Comments:: Date; " /a-�.-Ik Inspector: see back. nin FALSE ALARM FEE 1 st Alarm N/C 2nd Alarm : N/C. . 3rd Alarm N/C 4th Alarm $100 5th Alarm $150 : 6th Alarm $200 NON COMPLIANCE $150 Cont.Annual Inspection Fees, 3-11 Units price per unit $ . :5.36_ 12-25 Units price:per unit $ 4.82 26-50 Units price per unit, $' :4._29 51=100 Units price per unit $.. 3.75. , 100.or more Units price per unit . $ -2.68 Fire Safety re inspection types First Re-inspectiol N/C . Second.re-inspect $75. . . Third re-inspectior $ 125.00 Inspection scheduled,but cancelled 24 hrs $ 50.00 TOTAL �. . . . nm:. ; City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: 01)/C Date Received: 0— 2- 1 Site: Pen-nit Type: Approved w/no comments:2r/ Approved w/the below comments: F Denied w/the below comments: ❑ This comment sheet shall be kept with the permit and/or plans. 6 Brown Fire Safety Officer Date Contractor and/or Homeowner Gene � (Required when comments are present)