HomeMy WebLinkAbout18-20458 CITY OF ZEPHYRHILLS
5335-8TH STREET 20458
T (813)780-0020
BUILDING PERMIT
PERMIT INFORMATION LOCATION INFORMATION
Permit Number: 20458 Address: 5612 18TH ST
Permit Type: ADDITION/ALTERATION ZEPHYRHILLS, FL.
Class of Work: 434-ADD/ALT RESIDENTIAL Township: Range: Book:
Proposed Use: NOT APPLICABLE Lot(s): Block: Section:
Square Feet: Subdivision: CITY OF ZEPHYRHILLS
Est. Value: Parcel Number: 11-26-21-0010-11200-0200
Improv. Cost: 11,342.00 OWNER INFORMATION" -
Date Issued: 11/19/2018 Name: DALTON, CRAIG
Total Fees: 150.00 Address: 5612 18TH ST
Amount Paid: 150.00 ZEPHYRHILLS, FL. 33542
Date Paid: 11/19/2018 Phone: 813-393-9046
Work Desc: REPLACE 10 WINDOWS S/S
CONTRACTORS APPLICATION FEES
HOME PERFORMANCE ALLIANCE INC BUILDING FEE 150.00
I
Ins ections'Re uired
FOOTER 2 D ROUGH PLUMB Misc INSULATION CEILING
FOOTER BOND DUCTS INSULATED SEWER MISC.
ROUGH ELECTRIC LINTEL MISC MISC.
1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC.
DUCTS INSTALLED WATER MISC DRIVEWAY
PRE-SLAB SHEATHING MISC. MISC.
CONSTRUCTION POLE FRAME MISC. MISC.
REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or.
first reinspection,whichever is greater,for each such subsequent reinspection.
NOTICE: In addition to the requirements of this permit, there maybe additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing,consult with your lender or an attorney
before recording your notice of commencement."
Complete Plans,Specifications Must Accompany Application.All work shall be performed in accordance with
City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
CONTRACTOR IGNATURE PERMIT OFFI R
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021
Building Departmentp-
! 'Date Received Phone Contact for Permitting
1 1 1 1 1 1 1 I TT 1 A 1 1.1 1 1
Owner's Name -! Ir f 7 p C_(-o�,q Owner Phone Number
Owner's Address 5l0l p S-K Owner Phone Number
Fee Simple Titleholder Name Owner Phone Number
Fee Simple Titleholder Address
�
JOB ADDRESS 561a. { �1 1) ) 1 rL// /4ny0k
i `L^O�T# �V
SUBDIVISION P11000,
PARCEL ID# (OBTAINED FROM PROPERTY TAX
WORK PROPOSED e NEW CONSTR ADDIALT = SIGN DEMOLISH
DEMOLISH
INSTALL REPAIR
PROPOSED USE SFR Q COMM = OTHER
TYPE OF CONSTRUCTION = BLOCK Q FRAME = STEEL =
DESCRIPTION OF WORK U Q 1�LQ- 0 1
i
BUILDING SIZE SQ FOOTAGE HEIGHT
BUILDING $ /1'"1 VALUATION OF TOTAL CONSTRUCTION
=ELECTRICAL $ d\ AMP SERVICE Q PROGRESS ENERGY Q W.R.E.C.
=PLUMBING $ QI(`^�
=MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION Pp /
=GAS = ROOFING 0 SPECIALTY = OTHER ► // w
FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO v
BUILDER COMPANY
SIGNATURE REGISTERED Y/ N' FEE CURREN Y!N
Address License#
ELECTRICIAN COMPANY
SIGNATURE REGISTERED I Y/ N FEE CURREn I Y/N
Address License#
PLUMBER COMPANY
SIGNATURE REGISTERED I Y/ N FEE CURREN Y/N
Address License#
MECHANICAL COMPANY
SIGNATURE REGISTERED Y/ N FEE CURREN LILN
Address u, License# (�
OTHER , COMPANY rK� �'IYYlJ1�L 1TII11
SIGNATURE t-�p ^� c' REGISTERED Y/ N FEE CURREN/' I Y/N
Address 1180 105 c.Oi — License# C,(3rO—
IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII
RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction,
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence Installed,
Sanitary Facilities&1 dumpstei;Site Work Permit for subdivisionsllarge projects
COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction.
Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed,
Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance
SIGN PERMIT Attach(2)sets of Engineered Plans.
*• PROPERTY SURVEY required for all NEW construction.
Directions:
Fill out application completely.
Owner&Contractor sign back of application,notarized
If over$2500,a Notice of Commencement Is required. WC upgrades over$7500)
•• Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same
OVER THE COUNTER PERMITTING (copy of contract required)
Reroofs if shingles Sewers Service Upgrades A/C Fences(PlottSurvey/Footage)
Driveways-Not over Counter if on public roadways..needs ROW
s.
NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restrictions"
which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any
applicable deed restrictions.
UNLICtNSED CONTRACTORS AND CONTRACTOR--RESPONSIBILITIES:- If-the-owner-has-hired a-contractor-or
contractors to undertake work,they may be required to be licensed in accordance with state and local regulations. If the
contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation
understate law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the
intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847-
8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign
portions of the"contractor Block"of this application for which they will be responsible. If you, as the owner sign as the
contractor,that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco
County.
TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands
that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of °
use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and
90-07; as amended. The undersigned also understands,that such fees, as may be due,Will be identified at the time of
permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to
receiving a"certificate of occupancy"or final power release. If the project does not involve a certificate of occupancy or
final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact
fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances.
CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended): If valuation of work is$2,500.00 or more, I
certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's
Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone
other than the"owner",I certify that I have obtained a copy of the above described document and.promise in good faith to
deliver it to the"owner"prior to commencement.
CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work
will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is
hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has
commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating
construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also
certify',.that I understand that the regulations of other government agencies may apply to the intended work,and that it is
my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to:
-. Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive
Lands,Water/Wastewater Treatment.
-. Southwest Florida Water Management District-Wells, -Cypress Bayheads, Wetland Areas, Altering
Watercourses.
Army Corps of Engineers-Seawalls,Docks,Navigable Waterways.
-. Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment,
Septic Tanks.
US Environmental Protection Agency-Asbestos abatement.
Federal Aviation Authority-Runways.
I understand that the following restrictions apply to the use of fill:
Use of fill is not allowed in Flood Zone"V"unless expressly permitted.
If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a
"compensating volume"will be'submitted at time of permitting which is prepared by a professional engineer
licensed by the State of Florida.
- If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall
construction,I certify that fill will be used only to fill the area within the stem wall.
If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent
properties. If use of fill is found to adversely affect adjacent properties,the owner may be cited for violating
the conditions of the building permit issued under the attached permit application,for lots less than one(1)
acre which are elevated by fill,an engineered drainage plan is required.
If I am the AGENT FOR THE OWNER,I promise in good faith to inform the owner of the permitting conditions set forth in
this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work,
plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A
permit issued shall be construed to be a license to proceed with the work and not as authority to violate,cancel,alter,or
set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter
requiring a correction of errors in plans,construction or violations of any codes. Every permit issued shall become invalid
unless the work authorized by such permit is commenced within six months of permit issuance,or if work authorized by
the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced. An extension
may be requested, in writing,from the Building Official for a period not to exceed ninety(90)days and will demonstrate
justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned.
WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR
PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING Y UR NOTICE Ot COMMENCEMENT.
FLORIDA JURAT(F.S.117.03)
-OWNER OR AGENT CO TRACTO -
Subscribed and swom to(or affirmed)before me this Subscribed and swo'—o.(or_a nne fore me this`
_ —.. ,
bIt by` �1 --- .. �_---- -
Who Ware personally known to me or has/have produced Who is/are p onally known to me or has/have roduced
as identification. aaas Identification.
Notary Public Notary Public
Commission No. Com fission r
Name of Notary typed,printed or stamped Name of Notary
ooa.Pya JACQUELINE BOGES
+� _ Commission#FF 150422
F _K' Expires December 12,2018
...
pfi t,4 Bonded Thm Tray fain insurance 0
oo•3Bs.7oI9
Plan Review
Windows & Doors
1). Need manufacturing installation specifications:
2) -Must meet sections R308 and R612 of the 2017 F.B.C.
3) If windows are to be installed inside the historical district,they will need to be approved
by the historical committee.
4) No other work shall be permitted (framing, plumbing, and mechanical) unless otherwise
specified..,
5.) This is for replacement (glass for glass)only. if you wish to_change from screen or vinyl
windows to glass, then 'additional information is required.
6) All windows to wall connections shall b.e.left visible for. inspection. .
7) All labeling and stickers shall remain on windows until final inspection:
8.) No-work shall start without permit first.
Permit No. Parcel ID No 1 1-26-21-001 0-1 1 2 00-020 0
NOTICE OF COMMENCEMENT
State of Florida County of Pasco
THE UNDERSIGNED hereby gives notice that Improvement will be made to certain real property,and in accordance with Chapter 713,Florida Statutes,
the following information Is provided in this Notice of Commencement
1. Description of Properly: Parcel Identification No. CITY OF ZEPHYRHILLS PB 1 PG 54 THE W 112 OF LOTS 20 THRU 221NCL BLOCK 112 OR 9502 PG 3171
Street Address: 561218TH STREET ZEPHYRHILLS,FL33542 Illflll IIIII IIIII IIIIIIIIII II�II IIIII IIIIII�IIIIIIIIIIIIIIII
2. General Description of fmprovement Replace windows and or doors,size for size j
2018277755
3. Owner Information or Lessee information if the Lessee contracted for the improvement:
DALTON CRAIG
Name
561218TH STREET ZEPHYRHILLS FL
Address City State
Interest in Property: Owner 100
Name of Fee Simple Titleholder.
fCpt:1999346 Rec: 10.00
(If different from Owner fisted above) D$: 0.00 I T: 0.00
Address City 10/19/2018 K. K. , Dpty Clerk
4. Contractor. Home Performance Alliance
Name
1780102nd Ave Suite 500 SL Petersburg FL
Address City State
Contractor's Telephone No.: (727)538-4140 AULA S.O'NE I L,Ph.D.PASCO CLERK & COMPTROLLER
5. Surety: Name !10OR9BK01C� �5 fn pG 142
Address City
Amount of Bond: $ Telephone No.:
6. Lender.
Name
Address City State
Lender's Telephone No.:
7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by
Section 713.13(1)(a)(7),Florida Statutes:
Name
Address City State
Telephone Number of Designated Person:
8. In addition to himself,the owner designates of
to receive a copy of the Llenor's Notice as provided in Section 713.13(1)(b),Florida Statutes.
Telephone Number of Person or Entity Designated by Owner:
9. Expiration date of Notice of Commencement(the expiration date may not be before the completion of construction and final payment to the
contractor,but will be one year from the date of recording unless a different date is specified):
WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT
ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN
RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE
RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT
WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT.
Under penalty of perjury,I declare that I have read the foregoing notice of commence nt and that the fads stated therein are true to the best
of my knowledge and belief.
STATE OF FLORIDA
COUNTY OF PASCO
Signatilre of Owvf$r or ssee,or er's or Lessee's Authorized
Of ficc�er/DirectoriPartner/Man ager
V uk idr
Signatory's Title/Office np
�7 ,20(6 _t /`
The foregoing instrument was acknowledge�d S^before me this day of Gar G by A- ,'C�
as I�i A�r (type of authority,e.g.,officer,trustee,attorney in fact)for
- (name of pa behaff o om i ent was executed).
Personally Known❑OR Produced Identification Notary Signature
Type of Identification Produced t 9 3 5 (05 li N
0>-� �a(Print)
57
7F�
BRIAN COTHERN
= ;A,. MY COMMISSION#GO 214627
W EXPIRES:May S.2022
F�Q.`.
wpdetelba/noticecommencement�c053048 Bonded Thfu Notary Public Undetwiters
^
'
S fATEOp FLORIDA,COUNTY0FPASCO
THIS|STO CERTIFY THAT THE FOREGOING |SA
TRUE AND CORRECT COPY 0F THE DOCUMENT
ON FILE UROF PUBLIC RECORD |N THIS OFFICE
fill Muff
r_ 3
City of Zephyrhills
BUILDING PLAN REVIEW COMMENTS
Contractor/Homeowner: C-9--
Date Received: (0 - 6-- 16
Site: 5-� l 2- (f�k 5 t
Permit Type: i2,e,� (k ce W iV 6l ,J
Approved w/no comments:❑ Approved w/the below comments: Denied w/the below comments: ❑
This comment sheet shall be kept with the permit and/or plans.
018
-C-"-,.
Kal .in Switz fans Examiner Date Contractor and/or H meowner
(Required when comments are present)
' L HOME PE FORMANCE ALLIANCE, INC.
State Certified Garter I'Corttractor License#CGC1508826&CBC1258017
1780102nd Avenue;Suite 500,St.Petersburg,FL 33716
Office:800-472-5448•Fax:(727)538.4217
t www.hpawin Jowrs..corn-Email:help@HPAwindows.com
CONTRACT' „'Z-Z) I t
PURCHASER NAME MAIN PHONE `OTHER PHONE WORK PHONE
STREET) 6 { E-MAIL
cvlc.\�t31, u,c,1.C
CRY.STATE,A(lN yD ZIP CUSTOM LTERNATE PHONE:
Gt ( il !D 1 ✓/
SA E5 P _ REPS PHONE ( DATE
,/
General Description of Work: To furnish and Install: A/y �f4,e0 }d
Windows and I sliding glass doors and
entry doors -which is further described±in the details specification sheet attached hereto as Exhibit"A"
and initiated by the parties.We will remove and dispose of all debris from job site.Price below includes building permits and warranty.
The above work will be completed in accordance with the terms,conditions a d specifioation,,S,herein,with payment to be made in accordance
with the following payment schedule: CASH CONTRACT I FINANC CONTRACT
1. PROJECT PRICE $ ( lT �•
U'
2. INITIAL DOWN PAYMENT $
3. BALANCE DUE $
4. ADDITIONAL DOWN PAYMENT DUE $
UPON DELIVERY OF MATERALS
5 BALANCE DUE UPON'COMPLETION - $
6. BALANCE,TO BE FINANCED $
BALANCE DUE UPON INSTALLATION OF WINDOWS AND DOORS NOT AFTER THE FINAL INSPECTION
reeg .
Customer understands and aa there may be Items to be finished after the final Inspection.
I.E.Plugs and trim,stress cracks,additional caulking,etc,which Is covered under Warranties.
PAYMENT IS TO BE MADE BY CHECK PAYABLE TO'HOME PERFORM �NCEALLIANCE,INC.-ALL APPLICABLE DISCOUNTS HAVE
BEEN APPLIED ATTIME OFSERVICE.
Additional Comments:
All work is to be completed in a workmanlike manner according to standa¢practices.Any alteration or deviation from the above scope
of work involving extra costs will become an extra charge in addition to the q t15V
workers are full covered b Workmen's
Compensation insurance. Unless otherwise specified, Contractor's work(card ted workmanship warranty. The Contract
Documents consist of this proposal,the terns and conditions,all documents refetherein and the Limited Workmanship Warranty
and are incorporated herein by reference.
Buyer's Right to Candei: This is a home solicitation sate,and if y u do not want the goods or services,you may cancel this
agreement by providing written notice to the setter In person,by e-ma I or by certified mall.Telephonic communications do not
constitute valid notice of cancellation under this agreement.Saturda Is a business day for the purposes of this contract.This
notice must indicate that you do not want the goods or services and mdst be delivered or postmarked before midnight of the third
business day after you sign this agreement.If you cancel this agreement within the 3 day period,the seller may not keep any
cash down payment.If you cancel after the 3rd business day,you will1 be liable for a 30%liquidated damages fee in addition to
loss of your deposit.
i HAVE READ AND UNDERSTAND THiS CONTRACT,THE TERMS AND CONDITIONS
AND ALL DOCUMENTS REFERENCED THE EIN AND AGREE TO BE BOUND BY
THEIR TERMS.
ACCEPTANCE OF CONTRACT: The above prices, specifications Respectfully submitted,
and conditions are satisfactory and are hereby accepted.Contractor
is authorized to do the work as specified.By signing below,Customer HOME PERFORMANCE ALLIANCE,INC.
acknowledges that Customer is the owner of the property where work
is to be-performed.
Owner Signature: By:,(Orficer of Company)
Co-Owner Signature:
i
• Dealer Quotation - Quote 189254
O�T ® QUOTE EXPIRES
L 10250 Philipp Pkwy Phone: (330) 528 3400 30 DAYS FROM
mdowS Streetsboro, OH 44241, ..Fax: (330) 528 3501 REQUESTED
www.soft-lite.com =
Bid For Shipping:Address
HOME PERFORMANCE ALLIANCE INC 9843 18TH STREET NORTH
9843 18TH STREET NORTH ST PETERSBURG,FL 33716
ST PETERSBURG,FL 33716
Business: 727 538 4140
Fax: 727 538 4217
Quote Name: CRAIG DALTON
Customer Number PO Required Date Quoted By
707347 CRAIG DALTON 10/18/2018 davism
Line Qty Description
10-1 1 BCN Double Hung Double Hung 35.5 x 61
Comment/Room:
Viewed from Inside BED 2
Sill Type=SLOPED
n Base Color Soft-Lite White '� x
Full Flex Screen Betterwe V
Sill Expander=Y
n Lock Type=Standard
Lock Color=Sot-Lite White
Foam Fill=Spray Foam
IT Install Note=Yes
1
Reinforced Sash=Y
Double Locks=Y
35.5 g
RO-35.75 Glass Package=Solar Lowe&Argon
�- -�
e_ r, Clear=Yes
NFR_C i.!a_LuesJ Lowe=Solar Control SB70
FACTORF-,. ',�$HGC" Argon Gas
�'" Stainless Intercept
VT--- `CR Double Strength
0.45 57 Wrap=G
Page 1 of 6 Bid Dated: 10/18/2018 3:14 PM
Customer Number PO' Required Date. Quoted By
707347 CRAIG DALTON 10/18/2018 davism
Line Qty Description
20-1 1 BCN Double Slider XX 71.5 x 49
Comment/Room:
Viewed from Inside BED 2
Base Color=Soft-Lite White
1 Full Flex Screen Betterwe° I
Sill Expander=Y
n Lock Type=Standard 4 '
r Lock Color=Soft-Lite White
C Foam Fill=Spray Foam
Install Note=Yes
11 2
Reinforced Sash=Y
� 71.5 Double Locks=Y
ao-71.`5 Primary Sash=R
Glass Package=Solar Lowe&Argon
-� Clear=Yes
N�RC I�alues�! Lowe=Solar Control SB70
'U-FAC FOR Argon Gas
Stainless Intercept
`'•VT'"`—^ CR Double Strength
0.44 60 Wrap=G
Line Qty Description
30-1 1 BCN Double Slider XX 25.25 x 24.75
Comment/Room:
Viewed from Inside BATH
Base Color=Soft-Lite White
Full Flex Screen Betterwe 115 17 (XJ�j I
J , I
Sill Expander=Y (/
Lock Type=Standard
o Lock Color=Soft-Lite White
�A Foam Fill=Spray Foam
Install Note=Yes
3
Reinforced Sash=Y
Double Locks=Y
25 25 Primary Sash=R
RO-25-5 Glass Package=Solar Lowe&Argon
Clear=Yes
`- ,E RGSUlues' •.• Lowe=Solar Control SB70
;•�U-FACTOR_ SHGC Argon Gas
Stainless Intercept
VT_-- "Ck— Double Strength
0.44 60 Wrap=G
c
Page 2 of 6 Bid Dated: 10/18/2018 3:14 PM
Customer Number PO Required Date Quoted By
707347 CRAIG DALTON 10/18/2018 davism
Line Qty Description
40-1 1 BCN Double Slider XX 7135 x 49
Comment/Room:
Viewed from Inside BED 1
Base Color 1 Soft-Cite White Full Flex Screen Bettervue
Sill Expander=Y
n Lock Type=Standard
Lock Color=Soft-Lite White
Foam Fill=Spray Foam
Install Note=Yes
1 4
Reinforced Sash=Y
77"75 Double Locks=Y
no-rz
Primary Sash=R
Glass Package=Solar Lowe&Argon
Clear=Yes
�r--NFRC Values a Lowe=Solar Control SB70
JU'FACTOR' sSI3GC==� Argon Gas
� `ti'" '"�' ' Stainless Intercept
d.19 t' } P
{ VT' CR — Double Strength
0.44 60 Wrap=G
Line Qty Description
50-1 1 BCN Double Hung Double Hung 35 x 61.5
Comment/Room:
Viewed from Inside BED 1
Sill Type=SLOPED
Base Color=Soft-Cite White
Full Flex Screen Betterwe
�? Sill Expander=Y
Lock Type=Standard
Lock Color=Soft-Lite White
Foam Fill=Spray Foam
UInstall Note=Yes
5
Reinforced Sash=Y
Double Locks=Y
35 RO-35.25 ge owe Glass Package=Solar L &Argon
— —. ass
Clear=Yes
+1"'NFRC'Vitlues Lowe=Solar Control SB70
U-FACTOR MG �_ Argon Gas
Stainless Intercept
VT CR Double Strength
0.45 57 Wrap=G
Page 3 of 6 Bid Dated: 10/18/2018 3:14 PM
Customer Number PO Required Date Quoted By
707347 CRAIG DALTON 10/18/2018 davism
Line Qty Description
60-1 1 BCN Double Hung Double Hung 35 x 36.5
Comment/Room:
Viewed from Inside KITCHEN
Sill Type=SLOPED
Base Color=Soft-Lite White
Full Flex Screen Bettervue
Sill Expander=Y I �a
- — — Lock Type=Standard
p Lock Color=Soft-Lite White
X _ Foam Fill=Spray Foam
i
�( Install Note=Yes
6
Reinforced Sash=Y
35 Double Locks=Y
RO-35.25 Glass Package=Solar Lowe&Argon
— — : -"< :,, -- Clear='Yes
NFIiC=Valiles.J Lowe=Solar Control SB70
U-FACTOR_tiSHGC Argon Gas
Stainless Intercept
VT CR Double Strength
0.45 57 Wrap=G
Line Qty Description
70-1 1 BCN Double Hung Double Hung 23.75 x 36.125
Comment/Room:
Viewed from Inside KITCHEN
Sill Type=SLOPED
n Base Color r en Bette White �J v
Full Flex Screen Betterwe
Sill Expander=Y
j - Lock Type=Standard
Lock Color=Soft-Lite White
U i Foam Fill=Spray Foam
Install Note=Yes
7
Reinforced Sash=Y
2175 Glass Package=Solar Lowe&Argon
�- RO-24 Clear=Yes
Lowe=Solar Control SB70
i .1VF`RC values—i Argon Gas
`U=FACTO Stainless Intercept
Double Strength
-VT ' CR
Wrap=G
0.45 57
Page 4 of 6 Bid Dated: 10/18/2018 3:14 PM
Customer Number PO Required Date Quoted By
707347 CRAIG DALTON 10/18/2018 davism
Line Qty Description
80-1 1 BCN Double Hung Double Hung 35.25 x 59.75
Comment/Room:
Viewed from Inside LIVING
Sill Type=SLOPED
n Base Color=Soft-Lite White
Full Flex Screen Betterwe n a
Sill Expander=Y
Lock Type=Standard
Lock Color=Soft-Lite White
Foam Fill=Spray Foam
Install Note=Yes
8
Reinforced Sash=Y
Double Locks=Y
R05 35.5 Glass Package=Solar Lowe&Argon
Clear=Yes
v NFRCaY(zlues.u Lowe=Solar Control SB70
- _U-It1CTU12 SHGC`" Argon Gas
z 0.1= 019? `"` Stainless Intercept
VT CR Double Strength
0.45 57 Wrap=G
Line Qty Description
90-1 1 BCN Double Hung Double Hung 35.5 x 60.25
Comment/Room:
Viewed from Inside LIVING
Sill Type=SLOPED
n Base Color=Soft-Cite White 15�
KFull Flex Screen Betterwe `( v1
9
a Sill Expander=Y
o Lock Type=Standard
g Lock Color=Soft-Lite White
Foam Fill=Spray Foam
j IF Install Note=Yes
9
Reinforced Sash=Y
Double Locks=Y
35 RA-35 5.75 ass Gl Package=Solar Lowe&Argon
- �-.
Clear=Yes
NF_RCrT!alues:_'` Lowe=Solar Control SB70
`'U=FACTOR,.; SHGC_. Argon Gas
;"V . .t Stainless Intercept
03 "A;"_ 0i19
VT CR - Double Strength
0.45 57 Wrap=G
Page 5 of 6 Bid Dated: 10/18/2018 3:14 PM
Customer Number PO Required Date Quoted By.
707347 CRAIG DALTON 110/18/2018 davism
Line Qty Description
100-1 1 BCN Double Hung Double Hung 35.25 x 60.25
Comment/Room:
Viewed from Inside LIVING
Sill Type=SLOPED
Base Color=Soft-Lite White
Full Flex Screen Bettervu:e
d Sill Expander=Y �S._/ #o Lock Type=Standard
Lock Color=Soft-Lite White
Foam Fill=Spray Foam
Install Note=Yes
10
Reinforced Sash=Y
35.25 Double Locks Y
:10.35.5 Glass Package=Solar Lowe&Argon
--- Clear=Yes
(7 Values. Lowe=Solar Control SB70
FACTO Argon Gas
Gt- Stainless Intercept
019
'-VT_ CR Double Strength
6,45 57 Wrap=G
Page 6 of 6 Bid Dated: 10/18/2018 3:14 PM
Craig Dal ton. ;
s11898..
v ,
Vi
l
7
: . .
A1.1.... OR
�41
I _
of
CODES OD
��OF21DA 1,�
VAPTIOSN-
RD gDE5
\160
1
P�
Last Revision Date:.0918 Page 4 of 16
I�nGr:.. `Synchrony. .Sent to. •' - - --- _
Friday,October 5, 018 NotE ..
easure: '
�As% $11;242. :M Dave .
In Progress Inspection Required
.. . ..
class/Design n Pressure in PSF. 45 8;64;" : Wind Veloci rrt MP _.. _ 137_ $11$98
g �L. ) tY
• •
A licant Craig Dalton. Frame pe . . / Wood .: '
PP
Applicant Phone/Email - (813)_393-90461 cralgedalton@amail.com ' . Exterl0 Sid-Ing
It B ear u
Co-Applicant . . - - Y
co-Applicant Phone/tEmatt I Bucking Req '. .
. .
Contract°Date Color. � ��l`5 ` '
L�
Home 561218th.St
Grids'
-=---=-------=------------
Address - ---
Zephyrhills,FL 33542 : • Frosted
Gourity.. . :;Pasco;: Impact '' . Qty:
S:
Non1m act Y`s
Sales e'�
•:Erik.N`reh - -
pm
Phone Number (727)648-8434.. .
WindompShields My.
Email Address:. . : .'.erik6orth81@gmail.com DoorShelds .Qty. - "
Supervisor Melanie • Cust;,,lnit Customeragreei he above =
Nr ": Room. W H, -' ' ' Style Series OBS Temp'. .` Grlds Notes'_
J. .
a
„ .
12,
13 . ..
PENFi
14
16 . .
17
1 .
19 . .
20 ..
Do you have an HOA: Yes or:
Customer Signature:. •
(Please circle one
Measured By: �..
s I _. . Do you "live. a Flood zone:-
Date: - .. _•. -- _ .. (Please circle one) .. . Yes, -or No
.. .. . .
�b 'l.
Last Revision Date.0918 -Page 1 of 16
_
i
9/17/2018 Florida Building Code Online
f
BCIS Home Log In User Registration ( Hot Topics ; Submit Surcharge ':,: Stats&Facts Publications ( Contact Us I' BCIS Site Map I Links ( Search
Florida
r
Product Approval
,�; USER:Public User= �<t�:
Product Approval Menu>Product or Application Search>Application List>Application Detail
FL#. FL15780-R8
Application Type Revision
Code Version 2017
Application Status Approved � •
Il ��
Comments •
Archived ( 1
Product Manufacturer Soft-Lite LLC
Address/Phone/Email 10250 Philipp Parkway
Streetsboro,OH 44241
(330) 528-1136
PLangan@soft-lite.com
Authorized Signature Vivian Wright
rickw@rwbldgconsultants.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Windows
Subcategory Double Hung
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
0 Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the Lyndon F. Schmidt, P.E.
Evaluation Report
Florida License PE-43409
Quality Assurance Entity Farabaugh Engineering and Testing, Inc
Quality Assurance Contract Expiration Date 12/31/2018
Validated By Ryan J. King,P.E.
i✓J' Validation Checklist-Hardcopy Received
Certificate of Independence FL15780 R8 COI (b)Certificate of Independence.pdf
Referenced Standard and Year(of Standard) Standard Year
AAMA/WDMA/CSA101/I.S.2/A440 2008
AAMA/WDMA/CSA101/I.S.2/A440 2011
AAMA/WDMA/CSA101/I.S.2/A440 2005
ASTM E1886 2005
ASTM E1996 2006
ASTM E1996 2009
TAS 201,202,203 1994
Equivalence of Product Standards
Certified By
Sections from the Code
https://www.floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDgt3e1SAInEOW6yPiCnocELk3nHvFWLJoQah8YcpuwDiUg%3d%3d 1/3
9/17/2018, Florida Building Code Online
Product Approval Method Method 1 Option D
Date Submitted 06/11/2018
Date Validated 06/13/2018
Date Pending FBC Approval 06/18/2016
Date Approved 08/15/2018
Summary of Products
FL# Model,Number or Name Description
15780.1 a. "Imperial LS DH12"Double Hung Extruded PVC Double Hung Window-(X/X Configuration)
Window
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL15780 R8 II (a)Inst 15780.1.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409 j
Impact Resistant: No Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 15780.1 for Design Pressure Ratings,any FL15780 R8 AE (a) Eval 15780.1.pdf
additional use limitations, installation instructions and product Created by Independent Third Party:Yes
particulars.
15780.2 b. "5400 DH54(G5405)" Double Extruded PVC Double Hung Window- (X/X Configuration)
Hung Window
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL15780 R8 II (a)Inst 15780.2.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409
Impact Resistant: No Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 15780.2 for Design Pressure Ratings,any FL15780 R8 AE (a) Eva[ 15780.2.pdf
additional use limitations, installation instructions and product Created by Independent Third Party: Yes
particulars.
15780.3 c. "5400 DH54(G5405)" Double Extruded PVC Double Hung Window-(X/X Configuration)
Hung Window
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL15780 R8 II (a)Inst 15780.3.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409
Impact Resistant:Yes Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 15780.3 for Design Pressure Ratings, any FL15780 R8 AE (b) Eva] 15780.3.pdf
additional use limitations, installation instructions and product Created by Independent Third Party: Yes
particulars.
15780.4 d. "5300 DH53 (G5305)" Double Extruded PVC Double Hung Window-(X/X Configuration)
Hung Window
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL15780 R8 II (a)Inst 15780.4.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: No Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 15780.4 for Design Pressure Ratings,any FL15780 R8 AE (a) Eval 15780.4.pdf
additional use limitations, installation instructions and product Created by Independent Third Party: Yes
particulars.
15780.5 e. "5300 DH53 (G5305)"Double Extruded PVC Double Hung Window- (X/X Configuration)
Hung Window
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL15780 R8 II (a) Inst 15780.5.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409
Impact Resistant:Yes' Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 15780.5 for Design Pressure Ratings,any FL15780 R8 AE (b) Eva] 15780.5.pdf
additional use limitations, installation instructions and product Created by Independent Third Party:Yes
particulars.
15780.6 f. Series"Barcelona" Model"DH30I" Extruded PVC Double Hung"Impact"Window, Missile Level"C"
-(X/X Configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL15780 R8 II (a)Inst 15780.6.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E. 43409
hfps://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgt3eISA]nEOW6yPiCnocELk3nHvFWLJoQah8YcpuwDiUg%3d%3d 2/3
9/17/2018, Florida Building Code Online
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 15780.6 for Design Pressure Ratings,any FL15780 R8 AE (b) Eval 15780.6.pdf
additional use limitations, installation instructions and product Created by Independent Third Party:Yes
particulars.
15780.7 g.Series"Barcelona" Models"DH30I" .Extruded PVC Double Hung"Impact"Window, Missile Level"D"
&"DH30PI" -(X/X Configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL15780 R8 II (a)Inst 15780.7.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 15780.7 for Design Pressure Ratings,any FL15780 R8 AE (b) Eva] 15780.7.pdf
additional use limitations, installation instructions and product Created by Independent Third Party: Yes
particulars.
15780.8 h. Series"Barcelona"Models"DH30I" Extruded PVC Double Hung"Impact"Window, High Velocity
&"DH30PI" Hurricane Zone-(X/X Configuration)
Limits of Use Installation Instructions
Approve ruse in HVH FL15780 R8 II (a)Inst 15780.8.pdf
Ap roved for use outside HVH . s Verified By: Lyndon F.Schmidt, P.E.43409
pac esistant:Yes Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 15780.8 for Design Pressu Ratings,any FL15780 R8 AE (b) Eval 15780.8.pdf
additional use limitations, installation instructi s and product Created by Independent Third Party:Yes
particulars.
15780.9 i. Series"Barcelona" odels"DH30" Extruded PVC Double Hung"Non-Impact"Window- (X/X
&"DH30P" Configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL15780 R8 II (b) Inst 15780.9.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E. 43409
Impact Resistant: No Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 15780.9 for Desig ressure Ratings,any FL15780 R8 AE (b) Eval 15780.9.pdf
a ' 'onal use limitations, install n instructions and product Created by Independent Third Party:Yes
partic
Back Mext
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy tatement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic
mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.*Pursuant to Section 455.275(1),
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emails
provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here.
Product Approval Accepts:
2i eClvck 'tea:
Credit Card:
Safe
https://www.floridabuilding.org/pr/pr app_dti.aspx?param=wGEVXQwtDgt3elSAInEOW6yPiCnocELk3nHvFWLJoQah8YcpuwDiUg%3d%3d 3/3
.%.0%J11111#1
U)
61 SEX
tot 41. - -
z oz
Lite
Bringing quality to light.
10250 Philipp Parkway
Streetsboro,Ohio 44241 rr 111t,m
0 z
a ri
0 x
E. z z a
K
SEE CHART FOR SEE CHART FOR C W
0 M
"BARCELONA" FRAMEISIZES FRAME SIZES M 0.(,L
Model "DH30" and TH30P 0
E z
DOUBLE HUNG WINDOW ' 030.
'WON-IMPACr
2 1 L/
GENERAL NOTES
E2
0
1. This product has been evaluated ond'is in compliance with the 611h Edition(2017)Florida
Building Code(FBC)structural requirements excluding the"High Velocity Hurricane hI-------
Zond'(HVHZ). X V Y>-
00
2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment
to base material shall be beyond wall dressing or stucco.
When used in areas requiring wind bome debris protection,this product is required to be
in
:9 protected With an impact resistant covering that complies with FBC Sections 1609.1.2& z
R301.2.1.2. 2
V)
Model TH30" Model"DH30P'
4. For 2x stud framing construction,anchoring of these units shall be the some as that
shown for 2x buck masonry construction.
,_DESI.,DSI.
5. Site conditions that deviate torn the details of this drawing require further E.
,
engineering analysis by a licensed engineer or registered architect. 44
ANg'
zi
TABLEOFCONTEMIS "DH30r 36.0"x 77-1r 28.i2ex32.00" G11 +50.0 -50.0
SHEEN DESCRIPTION
Typical i z
1 elevations;design Pressures and general notes "DH30" 40.0"X 63.0" 32.125"x27.125" G1 +55.0 -55.0
2 , Horizontal ross sections 17 1z
"DH3V 54.0"X 76.0" "46.25x34.00" GI +35A -35.0 N.T.S.
3 Vertical cross sections
4 Buck and,frame anchoring —
5 Components 'DH30P" 40.0"X 63.0" 32.125"x 26.625" G1 +55.0 -55.0, QiK UY. IFS 6 Bill of terials and DRAMNGAM'.
"DH30P" 54.0"X76.0" 4625'x33.125" G1 +30.0 -30.0 FL—15780.9
I a Mir 1 or 6
R:\Clents\Soft-Ute Permanent\A-Florida Pmduct Approvals\FL-15780 Double Hung\C-Drawings\FL-15780(2017)-R3\FL-15780.94wg,2
_ o
Q n :E
O 0
3 N N
J 0 H
o'(D
3 CL
,v 0
0
c m
�n o. . .. . m
O Q W A
'O
N
tN
rn to
W N x
Z � n
T W td
13
ElW �•\\ �•�\ W W
a
p N N
_ D oo m
22
N
A A �0 A ma
oa W i
o A ❑ W
O
N
m
Z OD m
m
O
A 0 s
0
A 0
=ro a
;o
r
o D ;�
ty/l ❑
n o Go0
Z N r.e
m 0 0
v
I0 0 J `�� SCNM��
a
ZNo.43409
JUNE 11,2018
2 4 PRODUCT: Daeuma Proparoa By:
SOFT—LITE WINDOWS Lyndon F. Schmidt ///t��p'•
IN I Z ,°-�, to P.E. No. 43409 ////S \
Ln o - fll
1 PART OR ASSEMBLY: GD BUILDING CONSULTANTS, INC.
Ip X (A 1 6 11 18 ADDED FRAME SIZE JK P.O. Box 230, Valriao, FL 33595
D' co v NO DATE BY HORIZONTAL phone No.: 813.659.9197
REVISIONS CROSS SECTIONS FBPE CA No. 9813
0 2017 R.W.9111LDING CONSaI—NtS INC.' '
R:\Olents\Soft-Ute Pennanent\A-Florida Product Approvals\FL-15780 Double Hung\C-Drawings\FL-15780(2017)-R1\FL-15780.9.dwg,3
1-1/4"MIN, 1-1/4"MIN.
EMB.(TYP.) EMB.(TYP.)
A
m O ►s m m
A 0 o w w n
w to
oM Go
N"� • O n �
.b O
-0^ (I m u
O1n ''p 0 j;V
7G 0
S T
m
m 1-114'MIN.
EMB.(TYP.)
as
v m
I0
c y 136,
P, w
.oNl"`► CO
ate.d �
O Z !M Q
C2
I�
1-114"MIN. ry
EMB.(TYP.)
J 0
m 'A'1
m �
W
CI Ia� N
Cn a
nWa bf
�g,
�� ❑ Iss
o� o
� o
j N O
OR
o a .I SC!!Af,
1-iJ4"MIN. I� �. No, ••�
EMB.(TYP.)
JUNE 11,2018
PRODUCT:
Document.Prepared Bp a
PS �t o Lyndon F. Schmidt ff�rp�� ...�(1j�'ti�`�
SOFT—L1TE WINDOWS P.E. No. 43409
�///�/!BUILDING CONSULTANT", INC.
V PART OR ASSt7ABLY: YY P 0, Box 230, Valrioo, FL 33595
IOp y in 1 8 11 18 ADDED FRAME SIZE JK CROSSRSECTIONS UY Phone No.: 813.859.9197
1 to v NO DATE BY
REVISIONS FBPE CA No. 9813
0 201-7 R.W.BUILDING CONSULTANID IND.
FOR WIDTHS GREATER THAN 40 Q4004
(TYP•) (0-u�, v * :Q_K n
z r�.•r�, do
fh
\
0 n z
aD o t� xz�
eNg 9da
TYP. SASH `� �V1 W LL"� m a a
2X BUCK c ti
BUCK 'v FRAME — o1
Li
MEEIING ______ ———— MEETING
RAIL ——— } RAIL
2X BUCK F
MASONRY o L)
MASONRY `* OPENING I BUCK G W
OPENING DIRECT TO H }
SASH MASONRY co 5
HEAD 8 JAMBS
(TYP.)
o Y
` 7m
S
E
BUCKANCHORING FRAMEANCHORING
z
W Z
8 N �
UJ
CONCRETE ANCHOR NOTES:
F 1.Concrete anchor locations at the comers may be adjusted to maintain the min.
d edge distance to mortarjoints. o
2 Concrete anchor locations noted as"MAX.ON CENTER"must be adjusted to 0
$ maintain the min.edge distance to mortar joints,additional concrete anchors
may be required to ensure the'MAX.ON CENTER"dimension are not exceeded. m a
*; 3. Concrete anchor table:
d :.•: .. ..- :.::....:.,..,:..... ....., :i.:MIN C[EARA.NCE. . ao
_ANCHOR;:ANCHOR;?::::':MINS::ii:i:<,_. ........... .............................._ m m
70 MASONRY':::'. .70'ADJA:CENF::; _
TYPE..:, .:...:.SIZE.:;:;i:........ E I......:..........
:;.• ::: ::::::::::: :::•:•::::::•::::as::;:::a..............EDGE::":::1;:>`::`t;x:::;;ANCHOR 'i<: 'Z n
IT W DAm 9119117
TAPCON® 1/4" T-1/4" 2" 4" sr11F• N.T.S. o
€ ELCO DWG.BY: JK M'
v ULTRACON® 1" 4� cHK.BY: LFS 3
WOOD SCREW INSTALLA710N NOTES: maWM NO-' wn
1.Maintain a minimum 5/8"edge distance,I"end distance,8,1"o.c.spacing of FL-15780.9
n wood screws to prevent the splitting of wood. °a
o sHEEr 4 of 8 e
R:\Gents\Soft-Ute Permanent\+-Florida Product Approvals\FL-15780 Double Hung\C-Dmwings\FL-15780(2017)-RI\FL-15780.9.dwg,5
T', 0.059" 13
0
0
1.44" y
A
{ 0.41" a A ^ u
5 W 1 0.86„ O o
N �0.05, >a `9LI � G
c T
n
1.21" 3
1.0T' 1.05'
T5A03
M
CD
o �
o r o
oJ
CD
1.96" 1.21" 0.39 o j
1.07' �•— N o 1 1 N �' I a•
�1 a 0.093"
m
0
"1.96 I--1.63"--I
A Ff--1.7T' —{ 2.87'
s
o � Roo
n u 0.065'
H 1.19"
0.95' �►—
y
L Z _ ---r
0o y
vi n y W p
m t y
1.96"
4f G/ A
0
R �1
—►i 10.66"
2.39"
� y
Z a
111SCNMjO
0.2T'
:'• No.43409ir
JUNE 11,2018
g PRODUCT: Doeamente Prepared By:��
P Lyndon F. Schm[dt ���•••'• ORIDw%•••����
O SOFT—LITE WINDOWS P E. No. 43409 �'ss/pNAL
IO o Z m 7��71N 11►ttt�
r m r y O PART OR ASSEMBLY: •�K BUILDING CONSULTANTS, INC.
IO z N i 6 11 18 ADDED FRAME SIZE JK J 1� P.O. Box 230, Valrico, FL 33595
°f to v NO DATE BY COMPONENTS Phone No.: 813.659.9197
REVISIONS I FBPE C.A. No. 9813
®2017 R.W.BUILDING CONSULTANtS INC.
BILL OF MATERIALS `N�.��
MATERM .O o
N
A IX BUCK SG>=0.42 WOOD =Z`af 8 o jam=n
B 2X BUCK SG>=0.42 WOOD =V. a
C 1/4"MAX.SHIM SPACE y`y: Z
D 1/4"X 2-3/4"PFH ELCO OR ITW CONCRETE SCREW STEEL '., �'•,, yam.` =
E MASONRY-301 OR HOLLOW
BLOCK CONFORMING PSI MIN. OTOFAOTMIC OTO ACI CONCRETE � ������` o M m Z
F #8 X 2"PPH SMS(1-3/8"MIN.EMBEDMENT( STEEL °a
G 1/4"X 2-3/4"HWH ELCO OR ITW CONCRETE SCREW STEEL o E� z m o chi
H 1/4"X 2-1/4"HWH ELCO OR ITW CONCRETE SCREW STEEL u°a s `o a
1 FRAME` PVC W Lz a m a 0.LL
2 HEAD' PVC Z o o
3 WEEP HOLE COVER* PVC e �0
4 SILL ADAPTER' PVC o ��a .
5 TOP LIFT HANDLE' PVC
6 KEEPER RAIL" PVC
7 LOCK RAIL* PVC y -�
8 PLAIN STILE* PVC orra,
9 GLAZING BEAD* PVC z �
10 BOTTOM LIFT RAIL" PVC
11 REINFORCEMENT(6065-T5 ALUM) ALUM. 5/8"GLASS BITE 1/2"WIDE DBL SIDED GLAZING TAPE o�
12 REINFORCEMENT(6065-T5 ALUM) ALUM.
13 REINFORCEMENT(6065-T5 ALUM) ALUM. 7/8"THICK '� ��
14 HEADPOCKEfINSERT' PVC 1/8"ANNEALED OR TEMPERED GLASS ol�' o mQ
15 SLOPED INSERT' PVC
16 SLOPED SILL' PVC a a
G 20 LOCK Y r
DO21 LOCK KEEPER -
25 TILT LATCH AIR SPACE
g 26 #8 X 1"PFH TEK STEEL
27 #6 X 1"PFH TEK STEEL Oo 1/8'ANNEALED OR TEMPERED GLASS
28 WEATHERSTRIP(187-270TRI-FIN) Z
s 29 BULB SEAL STEEL INTERCEPT SPACER w o
m N
0 30 BULB SEAL Gl G[AIINGDEfA1L w
$ 31 PIVOT BAR STEEL
32 #7 X 3/4"PFH TEK STEEL
33 BALANCER BRACKET -
'THE APPROVED WHITE RIGID PVC EXTERIOR EXTRUSIONS FOR WINDOWS ARE TO BE PRODUCED BY i
EXTRUDERS LICENSEES IN"AAMA CERTIFICATIONS PROGRAMS FOR RIGID PVC EXTRUSIONS".
n
m 'm
E 1 0 0
g DATe91917 z
5 sGA E: N.T.S.
• 5
€ DING.BY. JK m
g CHN.BY. LFS
DRAWING N04
FL-15780.9 0
p SHEET 6 OF 6 0
O
s
1 011 2/2 01 8 moriaa tsuuaing L;oae uniine
big
BCIS Home i Log In ( User Registration I Hot Topics Submit Surcharge Stats&Facts i Publications Contact Us BCIS Site Map ( Links ( Search
Florida
i Product Approval
USER:Public User'
dj
Product Approval Menu>Product or Application Search>Application List>Application Detail
FL# FL15781-R8
+W Application Type Revision
Code Version 2017
Application Status Approved
Comments
Archived {:I
Product Manufacturer Soft-Lite LLC
Address/Phone/Email 10250 Philipp Parkway
Streetsboro,OH 44241
(330) 528-1136
PLangan@soft-lite.com
,
Authorized Signature Vivian Wright'
rickw@rwbldgconsultants.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Windows
Subcategory Horizontal Slider
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
C i Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed the Lyndon F. Schmidt,P.E.
Evaluation Report
Florida License PE-43409
Quality Assurance Entity Far-abaugh Engineering and Testing,Inc
Quality Assurance Contract Expiration Date 12/31/2019
Validated By Ryan J. King,P.E.
(�} Validation Checklist-Hardcopy Received
Certificate of Independence FL15781 R8 COI (g)_Certifiicate of Independence,p-if
Referenced Standard and Year(of Standard) Standard Year
AAMA/W DMA/CSA101/I.S.2/A440 2011
AAMA/WDMA/CSA101/I.S.2/A440 2008
ASTM E1300 2004
ASTM E1886 2005
ASTM E1996 2006
ASTM E1996 2009
TAS 201, 202,203 . 1994
Equivalence of Product Standards
Certified By
Sections from the Code
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?par6m=wGEVXQwtDgt3e1SAInEOW9Taf7MFDxJQgCR4F8K9N%2fsDYeoUiUZ2mQ%3d%3d 1/4
Product Approval Method Method 1 Option D
Date Submitted 02/13/2018
Date Validated 02/14/2018
Date Pending FBC Approval 02/22/2018
Date Approved 04/10/2018
Summary of Products
FL# Model,Number or Name Description
15781.1 a. "Imperial LS DSL12" Double Slider Extruded PVC Double Horizontal Slidinb Window- (XX
Window Configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL15781 R8 II (a)Inst 15781.1.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409
Impact Resistant:No Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 15781.1 for Design Pressure Ratings,any FL15781 R8 AE (a)Eval 15781.1.pdf
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
15781.2 b. "Imperial LS TSL12"Triple Slider Extruded PVC Triple Horizontal Sliding Window-(XOX
Window Configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL15781 R8 II (a)Inst 15781.2.pddf
Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant: No Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 15781.2 for Design Pressure Ratings,any FL15781 R8 AE (a) Eval 15781.2.pdf
additional use limitations,installation instructions and product Created by Independent Third Party: Yes
particulars.
15781.3 c. "5300 DSL53 (G5352)" Double Extruded PVC Double Horizontal Sliding Window-(XX
Slider Window Configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL15781 R8 II (b)Inst 15781.3.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409
Impact Resistant: No Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 15781.3 for Design Pressure Ratings,any FL15781 R8 AE (a) Eva] 15781.3.pdf
additional use limitations,installation instructions and product Created by Independent Third Party: Yes
particulars.
15781.4 d. "5300 DSL53 (G5352)"Double Extruded PVC Double Horizontal Sliding Window-(XX
Slider Window Configuration) .
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL15781 R8 II (b)Inst 55781.4.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 15781.4 for Design Pressure Ratings,any FL15781 R8 AE (a)Eval 15781.4.pdf
additional use limitations,installation instructions and product Created by Independent Third Party: Yes
particulars.
15781.5 e. "5400 SSL54(G5402)"Single Extruded PVC Single Horizontal Sliding Window-(OX or XO
Slider Window Configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL15781 R8 II (b)Inst 15781.5.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409
Impact Resistant: No Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 15781.5 for Design Pressure Ratings,any FLIS781 R8 AE (a) Eval 15781.5.pdf
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
15781.6 -If. "5400 SSL54.(G5402)"Single Extruded PVC Single Horizontal Sliding Window-(OX or XO
Slider Window Configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL15781 R8 II (b)Inst 15781.6.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409
https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgt3elSAInEOW9Taf7MFDxJQgCR4F8K9N%2fsDYeoUiUZ2mQ%3d%3d 2/4
Impact Resistant:Yes Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 15781.6 for Design Pressure Ratings,any FL15781 R8 AE (a) Eval 15781.6.pdf
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
15781.7 g. "5400 TSLF54"Triple Slider Extruded PVC Triple Horizontal Sliding Window-(XOX
Window Configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL15781 R8 II (a) Inst 15781.7.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 15781.7 for Design Pressure Ratings,any FL15781 R8 AE (a) Eval 15781.7.pdf
additional use limitations, installation instructions and product Created by Independent Third Party: Yes
particulars.
15781.8 h. "5400 TSLF54"Triple Slider Extruded PVC Triple Horizontal Sliding Window-(XOX
Window Configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FLIS781 R8 II (a)Inst 15781-&.pd.
Approved for'use outside HVHZ:Yes Verified.By: Lyndon F. Schmidt, P.E.43409
Impact Resistant:Yes Created by Independent Third Party: Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 15781.8 for Design Pressure Ratings,any FL15781 R8 AE (a) Eva] 15781.8.pdf
additional use limitations,installation instructions and product Created by Independent Third Party: Yes.
particulars.
15781.9 i.Series"Barcelona"Model "SSL30I" Extruded PVC Horizontal Sliding "Impact"Window, Missile Level
"C"Excludes Wind Zone 3 and 4(XO or OX Configurations)
Limits of Use Installation Instructions
Approved for use in HVHZ: No FLIS781 R8 II (b)Inst 55781.9.pdf
Approved for use outside HVHZ: Yes Verified By: Lyndon F.Schmidt, P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 15781.9 for Design Pressure Ratings,any FL15781 R8 AE (a) Eva] 15781.9.pdf
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
15781.10 j.Series"Barcelona"Model"SSL30I" Extruded PVC Horizontal Sliding "Impact"Window, Missile Level
. "D"Includes Wind Zone 4(XO or OX Configurations)
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL15781 R8 II (b)Inst 15781.10.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 15781.10 for Design Pressure Ratings,any FLIS781 R8 AE (a) Eval 15781.10.pdf
additional use limitations,installation instructions and product Created by Independent Third Party: Yes
particulars.
15781.11 k.Series"Barcelona"Model "SSL30I" Extruded PVC Horizontal Sliding""'Impact"Window,High
Velocity Hurricane Zone Large Missile(XO or OX
Configurations)
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL15781 R8 II (b)_Inst 15781.11.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E. 43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 15781.11 for Design Pressure Ratings,any FL15781 R8 AE (a) Eval 15781.11.pd
additional use limitations, installation instructions and product Created by Independent Third Party:Yes
particulars.
15781.12 1.Series"Barcelona"Model "TSL30I" Extruded PVC Triple Horizontal Sliding "Impact"Window,Missile
Level"C"Excludes Wind Zone 3 and 4(XOX 1/4-1/2-1/4 and
XOX 1/3-1/3-1/3 Configurations)
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL15781 R8 II (b)Inst 15781.12.pd
Approved for use outside HVHZ:Yes Verified By: Lyndon F. Schmidt, P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure:N/A Evaluation Reports
Other:See INST 15781.12 for Design Pressure Ratings,any FL15781 R8 AE (a).Eval 15781.12.pdf
additional use limitations, installation instructions and product Created by Independent Third Party:Yes
particulars.
15781.13 m. Series"Barcelona"Model Extruded PVC Triple Horizontal Sliding"Impact"Window,Missile
"TSL30I" Level "D" Excludes Wind Zone 4(XOX 1/4-1/2-1/4 and XOX
1/3-1/3-1/3 Configurations)
https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgt3elSAInEOW9Taf7MFDxJQgCR4F8K9N%2fsDYeoUiUZ2mQ%3d%3d 3/4
Limits of Use Installation Instructions
Approved for use in HVHZ: No FLIS781 R8 II (b)Inst 15781.13.Of
Approved for use outside HVHZ: Yes Verified By: Lyndon F. Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 15781.13 for Design Pressure Ratings,any FL15781 R8 AE (a) Eva[ 15781.13.pdf
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
15781.14 n. Series'Barcelona"Model "TSL30I" Extruded PVC Triple Horizontal Sliding"Impact"Window, High
Velocity Hurricane Zone Large Missile(XOX 1/4-1/2-1/4 and
XOX 1/3-1/3-1/3 Configurations)
Limits of Use Installation Instructions
Approved for use in HVHZ:Yes FL15781 R8 II (b)Inst 15781.14.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant:Yes Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 15781.14 for Design Pressure Ratings,any FL15781 R8 AE (b) Eval 15781.14.pdf
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
15781.15 o. Series"Barcelona"Model"DSL30" Extruded PVC Horizontal Sliding "Non-Impact"Window(XX
Configuration)
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL15781 R8 II (b) Inst 15781.15.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt, P.E.43409
Impact Resistant: No Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 15781.15 for Design Pressure Ratings,any FL15781 R8 AE (b) Eval 15781.15.pdf
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
15781.16 p. Series"Barcelona"Model"TSL30" Extruded PVC Triple Horizontal Sliding"Non-Impact"Window
(XOX 1/4-1/2-1/4 and XOX 1/3-1/3-1/3 Configurations)
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL15781 R8 II (b) Inst 15781.16.pdf
Approved for use outside HVHZ:Yes Verified By: Lyndon F.Schmidt,P.E.43409
Impact Resistant: No Created by Independent Third Party:Yes
Design Pressure: N/A Evaluation Reports
Other:See INST 15781.16 for Design Pressure Ratings,any FL15781 R8 AE (b) Eval 15781.16.pdf
additional use limitations,installation instructions and product Created by Independent Third Party:Yes
particulars.
Back Next
Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824
The State of Florida Is an AA/EEO employer.Copyright 2007-2013 State of Florida.::Privacy Statement::Accessibility Statement::Refund Statement
Under Florida law,email addresses are public records.If you do not want your e-mail address released In response to a public-records request,do not send electronic
mall to this entity.Instead,contact the office by phone or by traditional mail,if you have any questions,please contact 850.487.1395.'Pursuant to Section 455.275(1),
Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emalls
provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please
provide the Department with an email address which can be made available to the public.To determine if you are a licensee under Chapter 455,F.S.,please click here.
Product Approval Accepts:
®®
Credit:Oc4d
hftps://www.floridabuilding.org/pr/pr app_dti.aspx?param=wGEVXQwtDgt3elSAInEOW9Taf7MFDxJQgCR4F8k9N%2fsDYeoU!UZ2mQ%3d%3d 4/4
```,ttttitl* fj lrf/01,
All
a�C
�`.
41
Bringing quality to tight. SE-CHART FOR FRAMESizls tel� ts,��♦♦{� z o m o
10250PhTppParkway a..
Streefsboro,Ohio 44241dq
\ Z -Z,
�\ P 9m°n'
rL N mp.W4.
"BARCELONA" o�x
Model "DSL30"
SLIDING WINDOW �
"Nt3N-rmmcr} x X o 4
z
o
GENERAL NOTES Q
1. This product has been evaluated and is in compliance with the 6th Edition(2017)Florida
Building Code(FBC)structural requirements excluding the"High.Velocity Hurricane Zone" t f
(HVHZ). _
V'
2. Product anchors shall be as fisted and spaced:as shown on details.Anchor embedment z
to base material shall be beyond wall dressing or stucco. �
gg in
3. When used in areas requiring wind bonne debris protection,this product is required to be N
. protected with.an impact resistant covering that compiles with.FBC Sections 1 bt I,2,& W
=" d. For 2k stud framing construction,anchoring of these units shall be the same as that shown
for 2x buck.mosonry construction.
i
5. Site conditions that deviate from the details of.this drawing require.further _
$ engineering analysts by a licensed engineer or registered architect.
b TABLE OF CONTENTS #u _o 0
E
� =AAAX� " ri';�MAXm=6=''�„'' ''" ,;,DFStGN:t'RE$St1RE{PSf):_�, ti a
a SHEETS- DESCRIPVON
=`Fastt,�t,"t,�s , „�Nt' 1}.t��;z'�-
-v.
:.. M,_
€ 1 t kai elevations,design pressures and general notes - - ' �'�.ra7Yt'�^='•"=F.(3S11i11�, �NEG7{i7VE�`I 9
g Pre "'
2 .,,.;..D(MEMSfONt cW�;DUyENS10N=w�::...._..... '..;...M..,.._, seas: .N.T.5.' _
2 Hortrontal cross sections DWG.�, JK 'm
3 Vertical"cross sections 73.W X 630 '31.43rx 54.375" GI +40.0 -40.0 LFS
4 Buckand.frameanchoring rc
DRAWtt1D NO.
r 5 Cgmponents 63.0"X44:0" 26.43rx35.375" G1 +55.0 -55A FL—t5781.75 n
6 Bill of materials and gloring detail ii
M - SHEET t OF $ .�
`v
d
MClientA\Soft-Lite PI,manent\A-Florida Product Approvals\FL-15781 Horizontal Sliders\C-Drawings\FL-157816TH ED(2017)\FL-15781.15.dwg,22
eel'-
M
c: v A
T Z
0
'O
cn' N
Q )
W N
�O N W �( HIM ln�
•O
NA Nbr
N
fN
n
�Z m
N N s a
U•o � N � 4 O
O Z v
.
Z o oNo
R�
0 0 0
Ln
U
22
�o
Z
(^I A
O N fn H1 G
O n m
2 U N W D
O C*
�z
n O n FE
N
O m as o
�A � � O
-:�3E m A
�z
0.43409
``lpuurnl�i
T PRODUCT: Documents Pmpered•By.i� r
r SOFT—CITE WINDOWS Lyndon F. Schmidt ����••• �ORIC7`•• ���
IN I D p P.E. No. 43409 '���s/pNAI. 6�•
2
w 00
(b r PART OR ASSEMBLY: ��/BUILDING CONSULTANTS, INC.
I� ini 1 25/18 REVISED PRESSURE RATINGS LFS YY P.O. Box 230, Valrroo, FL 33595
En � NO DATE BY HORIZONTAL Phone No.: 813.659.9197
REVISIONS CROSS SECTIONS F13PE C.A. No. 9813
®2017 R.W.BUILDING CDNBULTANtB INC.
RALlients\Soft-Cite Permanent\A-Florida Product Approvals\FL-15781 Horizontal Sliders\C-Drawings\FL-157816TH ED(2017)\FL-15781.15.dwg,32
Inn N ar m
Qe n W Cp . m f7
o 0o
o
g� ar I I o o
O N
N z
T N Q
cc
O O Do
Z .n m N •O O O
m
1-1/4°MIN. I-1/4"MIN.
EMB.(TYP.) B.
m
m
a W oo ONo
A
n � .o co
o
a -
W N
D rn a r= F
n
X
c A
0 I o C==
mN
C
� n O N N
O O Go IO O O0
O z m
� •o O � O
1-1/4"MIN. 1-1/4"MIN.
EMB.(TYP.) B.(TYP.)
N
m O W C n m
C4 •o co =
M
W W
o
;s
a'm
o r�
.. ti O N Cm Z CO tb Iz Cm O .
= m N •O y
1-1/4,MIN.
1-1/4"MIN. EMB (TYP)
EMB.(TYP.)
`tttllllll//j7j
No.43409
PRODUCT: Do
cuments Prepared By:i�
N = uwcw
x E
ndon F. Schmidt .........
�R
R o SOFT-UTE WINDOWS P E• No. 43409 /� .. ��`
IW V o Z o �� i1NAL11t�t`�
r oo r— y m PART OR ASSEMBLY- BUILDING CONSULTANTS.. INC.
�t (A 1 1 25 18 REVISED PRESSURE RATINGS LFS V vw P.O. Box 230• Valrlco• FL 33595
IO7 �7 NO DATE BY CROSSRTI SECTLIONS Phone No.: 813.659.9197
REVISIONS FBPE CA. No. 9813
0 2017 R.W.alllLOING CONOIII_TANt9 INC.
d)-.-(
aM
6"�P.1 SASH �VYP.) 4(TYP.) '�I/IrHr ��l�i���` c°�c"'+�z
6(TYP.}�
»: t
6 c
m d a0 IL
I)
c p
CZ
oEELJ
II (� 2XBUCK
Q II TYP. BUCK iI iXBUCK G z
BUCK II II' DIRECTTO —
I!
FRAME—'-- II MASONRY H i=
MASONRY 11 MASONRY (I (TYP.) a z ¢
OPENING I I OPENING
w
�• �T.' �O •1.• `• Jrli
a
uE BUCKANCHORING
b FRAME ANCHORING z
Vi �QQ
Z
� p
S N U)
CONCRETE ANCHOR NOTES. a w
1.Concrete anchorlocafions at the comers may be adjusted to maintain the min.
edge distance to mortar joints. W
2.Concrete anchor locations noted as MAX.ON CENTER"must be adjusted to �
maintain the min.edge distance to mortarlolnts,additional concrete anchors
c may be required to ensure the MAX.ON CENTER"dimension are not exceeded.
3.Concrete anchor table: N15
a MiN:CfAtNC :::'h}} :'Gi4.RANCE:
p R;ANCH01.. f bit?: i+N...... .......:...:...........:......::i:>;;;;i......•..;...;....,..,....;...a•:
:...:..:....................:::..... . ..:...::.....::::::car:>:»>::..:::..:..:....:•::;;;::: z a
::::::EpGF.-::r.::::..:::.:-:::::•::..._.... cti 70 08 77 i
.• :TiW n 114° la/a" T 4" a
TAPCON sum* N.T.S.
ELCO mvc.BY: JK m
ULTRACONe 1/4" 1-1/4 1" 4" CML at LFS 3
WOOD SCREW INSTALLATION NOTES.,
a distance,1"end distance,&1"o.c.spacing of o�
1.Maintain a minimum 518"edge p 9 FL---15787.i5 =
n wood screws to prevent the splitting of wood. ro
sHm 4 or 6 O
o _
P,\Oients\Sok-Lite Pennanent\A-Florida Product Approvals\FL-15781 Horizontal Sliders\C-Drawings\FL-157816TH ED(2017)\FL-15781,15.d g,52
' �1.5"J �o
N
0
H c o -• O a
y k3
0
s �
N
s
1.07' o
0
2.25" y
F- 2.W
121"
I.OT r
O
o 8
_ a T _1
O 1 0,28"
o
0.84"�{
1 2S
0.62"
C
m
T A
T
�0.089" o
1.05-
0.41"
0
W o 0.62 -fR
P P 0.86'
A _ O.OS
N
fr T w m
1 p
myu
ZQP
0.09r
� n ttuunpr r
0.130" 1--1.05" N0.43409
n
PRODUCT: Downnrxa Prepared B,:i� t• �
SOFT—CITE WINDOWS P Ed No.F. a Idt 'p•�'•.�ORID�.%
$ PART OR ASSEMB (71�`/BUILDING CONSULTANTS. INC.
'� Uf 1 1 25 15 REVISED PRESSURE RATINGS LFS COMPONENTS YY P•0. Box 230. Volrfoo, FL 33595
°i v NO DATE
BY Phone No.: 813.859.9197
to
REVISIONS FSPE C.A. No. 9813
®2017 R.W.8,.,�LDINe CONBUIr<N[9 INC.
, t
BILL OF MATERIALS
..........
am MATERIAL
A IXBUCKSG>=0.42 WOOD 8 !-dcs
te,
B 2)(BUCKSG>--0.42 WOOD
C I/,f'MAX.SHIM SPACE :40
D 114*X 2-3/4"PFH ELCO OR ITW CONCRETE SCREW STEEL
MASONRY-3,000 PSI MIN.CONCRETE CONFORMING TO ACI
E 1301 OR HOLLOW BLOCK CONFORMING TO C90 CONCRETE Z'c;;6
F). z
F 1#8-15 X 2-1/2!TRUSS HEAD SMS(1-3/6'MIN.EMBEDMENT) STEEL n..I
0,4
G 1/4"X 3-1/4"HWH ELCO OR ITW CONCRETE SCREW STEEL z z
Em -m10 o o
H I/,C'X 2-314"HWH ELCO OR fTW CONCRETE SCREW STEEL 96c w
0 a.
V FRAME* PVC 93 WEEP HOLE COVER* PVC I
oz
4 DSL FRAME FILLER* PVC m
5 DSL HANDLE SASH* PVC
6 1 KEEPER RAIL* PVC 5/8'GLASS BITE 7/8"THICK
7 LOCK RAIL* PVC C== I/8"ANNEALED
8 DSL MAIN SASH* PVC
9 GLAZING BEAD* PVC obi
10 DSL COVER* PVC
4.
11 ANTILIFT TRACK' PVC
ry 12 ROLLER SILL TRACK ALUM. m
13 REINFORCEMENT(6065-T5 ALUM) ALUM. AIRSPACE
14 REINFORCEMENT(6065-T5 ALUM) ALUM: 1/6'ANNEALEI)
15 REINFORCEMENT(6065-T5 ALUM) ALUM. of
19 ROLLER ASSM. 1/2'GLAZING TAPE
20 LOCK GLAZING DETAIL STEEL INTERCEPT SPACER --------
21 LOCK KEEPER I - E�i
22 #7 X 3/4'PFH TEK(LOCK) Ss
26 #8 X I"PPH TEK(KEEPER) Ss
-'S 28 WEATHERSTRIP(187-270TRI-FIN)
*THE APPROVED WHITE RIGID PVC EXTERIOR EXTRUSIONS FOR WINDOWS ARE TO BE PRODUCED BY
EXTRUDERS LICENSEES IN"AAMA CERTIFICATIONS PROGRAMS FOR RIGID PVC EXTRUSIONS".
z
Z Ln
IL
w
z z-0
z I v
DATE-.10/08/17
SCALL N.T.S.
M. JK
a! ByE LF S
Zf-1581-1 5
6 ov
8