18-20646
CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 20646 BUILDING PERMIT PERMIT INFORMATION , LOCATION.INFORMATION Permit Number: 20646 Address: 5931 GALL BLVD Permit Type: MECHANICAL ZEPHYRHILLS, FL. Class of Work: ADD/ALT COMMERCIAL Township: Range: Book: Proposed Use: COMMERCIAL Lot(s): Block: Section: Square Feet: Subdivision: CITY OF ZEPHYRHILLS Est. Value: Parcel Number: 10-26-21-0020-00000-0050 Improv. Cost: 8,475.00 OWNER INFORMATION Date Issued: 1/08/2019 Name: ZEPHYR 11 LLC Total Fees: 127.50 Address: 14524 N ROME AVE Amount Paid: 127.50 TAMPA, FL. 33613-2029 Date Paid: 1/08/2019 Phone: Work Desc: INSTALLATION REFRIGERATOR COOLER DOLLAR GENERAL CONTRACTOR (S). APPLICATION FEES SOUTHERN AIR MECHANICAL SERVICES MECHANICAL FEE 127.50 nc�✓ Inspections-Re uired DUCTS INSTALLED DUCTSINSULATED FINAL REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection. NOTICE: In addition to the requirements of this permit, there maybe additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRACTOR SIGNATURE PERMIT OFFI R PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department J'n 110 Date Received Phone Contact for Per mitting F 352 472 4001 Owner's Name ZEPHYR LLC Owner Phone Number owner's Address 17162 Reading Rd.,Ste.730 Cincinnati,OH 45237 Own'erPhone Number Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS 5931 Gall Blvd. Zephyrhills,FL 33541 LOT# SUBDIVISION Pine Grove PARCEL ID#FIO-26-21-0020-00000-01 00 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED R IN NEW CONSTR ADD/ALT SIGN DEMOLISH STALL REPAIR PROPOSED USE SFR Q COMM OTHER I Reach-in Refrigeration Cases TYPE OF CONSTRUCTION Q BLOCK Q FRAME 0 STEEL supplied,100%self-contained reach-in refrigeration cases. 4=Re In Coolers, DESCRIPTION OF WORK 1=01"U=rs. No plumbing, Use heated eva ans. Pre-chamed from facto BUILDING SIZE SQ FOOTAGE= HEIGHT ffB UILDING VALUATION 0 F1 F TOTAL CONSTRUCTION =ELECTRICAL 1$ AMP SERVICE 0 PROGRESS ENERGY W,R.E.C. =PLUMBING 1$ *a ©MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION 8,475.00 —1 =GAS ROOFING Q SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS I FLOOD ZONE AREA =YES NO . . . . . . . . . . . . . . . . . . . . . . . . . . BUILDER COMPANY SIGNATURE REGISTERED I Y1 N FEE CURREt, L_Y/N Address I License J7_ ELECTRICIAN COMPANY = SIGNATURE REGISTERED Y/ N FEE CURREN T_/N Address License# PLUMBER COMPANY = SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address License# I ' �11 If MECHANICAL COMPANY [Southern Air Mechanical Services,LLC SIGNATURE REGISTERED I Y/ N FEE CURREN Y/N —1 I Address P519 SE State Road 26 Trenton,FL 32693 License# CAC050395 OTHER COMPANY SIGNATURE REGISTERED I Y/ N FEE CURREN L_Y�N Address License# RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster-,Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&I dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. -PROPERTY SURVEY required for all NEW construction. . . . . . . . . . . Directl .. Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement Is required. (AIC upgrades over$7500) Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs If shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW Dollar General 1530 5931 Gall Blvd. Zephyrhills, FL 33541 NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed7estrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work,they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work,they are advised to contact the Pasco County Building.Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the"contractor Block"of this application for which they will be responsible. If you, as the owner sign as the contractor,that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE:RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings, change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees, as may be due,will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a"certificate of occupancy"or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended): If valuation of work is$2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner"prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction,zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. Army Corps of Engineers-Seawalls,Docks,Navigable Waterways. Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. US Environmental Protection Agency-Asbestos abatement. Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone"V"unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume"will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - - If the fill material is to be used in Flood Zone,"A" in connection with a permitted building using stem wall construction,I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties,the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill,an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate,cancel,alter,or set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans,construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced. An extension may be requested, in writing,from the Building Official for a period not to exceed ninety(90)days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICEnuu� OMM CEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF Y TEN OBTAI FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOTI F COM ENCEMENT. FLORIDA JURAT(F.S.117.03) OWNER OR AGENT CONTRACTOR Subscribed and sworn to(or affirmed)before me this Sub rib d nd s rn t (or ed)before m this by / Who is/are personally known to me or has/have produced W o i are ersonall known to m or has/have produced as identification. as identification. Notary Public Notary Public Commission No. Commission N ro � Notary-Public State of Flonda Lisa M Davis Name of Notary typed,printed or stamped Name of Notary typed,printed or stamped '� ission GG 278362 '?j -d Expires 1210612022 Install 1000%self-contained reach-in refrigeration cases. ALL WORK SHALL COMPLY WITH PREVAUNG (2)5 door freezers (2)5 door coolers CODES FLORIDA BUILDING CODE, Rc-V1EW DATE (2)4 door freezers (2)4 door coolers NATIONAL ELECTRIC CODE, - ORDINANCES PLANS E DOLLAR GENERAL de INER �n�rsrr PAftIMIN1IRY: DATe OM18/18 w RIP [1] 05/16118 RIP S ar wvr [2] DRAWING HISTORY .� DATE 11-26-18 8Y: RLP REST pmu IL=ST ptsT -,�� '� 6 DATE: DY: �: � � em • •a 1��- vt [11 fl00N RO0.V d �' � I N' ■ C T� anon l`1 •' �.!, :._ _gip: I _ w m e - [31 .nv< _! x e E� 151 -.-:�- ------a------------ -rsm-: 6 - 61 o•mv u•v. .cm. 181 191 a' i= _ ,w R10JEOTTYPE RELOCATION- COW CO GP18 urwnrae .� .. .. .. C�y w.rm,vvu '^ n.v.nmw "' OPT LP MISMATM /, a STANDARD ENHANCED nxnmmDAIR ..v.,.r.w - SAMA.EA �..:m ,..n...•�� 01/07/19 + ll@IIS:11'd = s SUESFmmsum. a { .a N�• re — 2 9,831 RE �! 9s WAREH SOM mmso : .m E _ 3,972 RuoM 1 g �a 1--. o t . ® 3 �•. .�. OPEN :.�.� v.v.r.N•u�j ..e.n.ma' ,ems v.v...•w �c SEISUMSEMM S 46 Tg .......� a� . s '— 3291 44 ST0 ialE [ ' b, z 01530 A. MM 5MI GALL BLVD. ST1TE Ye^.' a R. 3m2 STORE PLA9NN]NG HOTLINE Highlight" Merchandiser RHCC30 & RHZC30 Hybrid' Specs Medium and Low Temp Hybrid"'Reach-Ins with 30"x 68" Doors Note:All Zero Zone display cases manufactured for shipment within the U.S.meet or exceed current DOE energy requirements. Medium Temp Low Temp PHYSICAL DATA 2RHCC30 3RHCC30 4RHCC30 5RHCC30 �� 2RHZC30 3RHZC30 HZC30 5RHZC30 Facings ft') 27.8 41.4 27.8 41.4 -qi Packout(ft') 56 83 16 83 Shelf Depth(in.) 24 24 41 10 24 24 �ig , T Weight(lbs.)* 783 1,033 80 , 783 1,033 1 , L *Does not include weight of condensing unit Weights include 2 end panels at 54 lbs.per pair. X-Z X Zero Zone ChillBrite"5 LED Lighting,Zero Zone CoolView Envision Standard No-Energy Doors, ELECTRICAL DATA" SSC Fan Motors w/Cond Evap System MOCP(amps)1 15 15 15 15 20 2 40 40 1 1 MCA(amps) 5.7 8.5 10.8 2.0 8.4 24.4 30.8 36,6J ENERGY DATA 11.1 11.9 15.0 Daily Energy Use(kh) F 25.6 33.4 42.2 52.2 Rejected Heat(13tuhW)4 1008 1,236 1,699 1 2,143 3,634 1 4,742 5,998 7,422 R-448A CHARGE R448A Charge(lbs.) REFRIGERATION Zero Zone Condensing Unit# 69-9933 69-9934 69-9935 69-9936 69- 6 69-9970 69-9970 Grated Weight(lbs.) 100 100 100_ 100 110 120 0 150 L I Zero Zone ChillBrite"5 LED Lighting,Zero Zone CoolView Envision"Standard/No-Energy Doors, ELECTRICAL DATA 1,2 SSC Fan Motors w/o Cond Evap System I MOCP(amps)1 15 15 5 15 15 20 35 35 MCA(amps) 5.7 7.8 8.6_T 1 2 � 10.6 12.2 8.2 4.6 303 ENERGY DATA 41.4 51.2 6.9 11.5 14.5 25.2 32.8 Daily Energy Use(kh) F-8.4 F Rejected Heat(BtuhW)4 980 1,193 1,641 2,063 3,577 L 4,657 5,884 7,279 R-448A CHARGE R448A Charge(lbs.) REFRIGERATION Zero Zone Condensing Unit 69-9933 69-9934 69-9935FiT-9936 1 69-9929 69-9930 69-9970 69-9970 Crated Weight(lbs.) 100 100 100 1 100 1 110 120 150 150 Notes: - 1. 208V 4-wire service;11 5/208V-1 PH-60HZ;red&black power,'white neutral,green ground.Buck/boost transformer available for low voltage conditions. 2' Main service disconnect Is not provided. 3' MOCP=Maximum over-current protection. 4. Adequate ventilation must be provided to dissipate rejected heat from the top of the unit for proper performance,Clearance of less than V above the top of the shroud to the coiling requires special design consideraUons.See Zero Zone Hybrid"Installation&operation Manual for specific details. 5, Refrigerant charge Includes combined condensing unit and case charges. 6. See separate reach-in case spec sheets for additional details:RHCC30&RHZC30. Factory-Installed Hybdd'Features: ■ Refrigeration piping With quick-connect couplings and refrigerant charge. ■ Pre-wired and labeled for easy connection. ■ Electronic control includes:time clock,temperature and defrost control,visual and audible temperature alarm,and network communication capability. Field-installed Hybrid'Features: ■ 20 1/4'tall aluminum shroud(front and sides standard,rear optional).Consult factory for other options. ■ Condensing unit with quick-connect threaded couplings, • Condensate collection and removal system:collection pan,pump,float switch,condensate dissipation pan with heater element,and connecting tubing, SS-67-A 1/17/18 Highlight7i Merchandiser RHCC30 & RHZC30 Hybrid' Specs EiiEa Medium and Low Temp.Hybrid'm Reach-Ins with 30"x 68" Doors 1'"�TCONNECTION REFRIGERATION (TYR) 3 3/4° EYCONDENSATE CONDENSING EVAPORATOR UNIT ' ' b" ELECTRICAL 2 621/8' n BOXLOWER 3 921/2" (TYR) 4 123" 5 153 3/8" 2112' �--461/4" ELECTRICAL END 21/2, BOX UPPER PANEL (TYR) Top View LOWER POSITION INCREASES CASE DEPTH TO 42118" 24° SHELF 64112" 66° INTERIOR DOOR 82 3/8° HEIGHT HEIGHT CASE HEIGHT 121E CONDENSATE 33 318°(DRAIN CENTER) 1 3/4" BASE PUMP 35518"(KICKPLATE) HEIGHT 36112'(BUMPER) L2 HAT 37'(DOOR HANDLE) CHANNEL RAIL • Door size:30'x W. • All dimensions are nominal. ■ Peg,gravity-feed,and other merchandising options available. • 2112'End Panels are included. • Optional base configurations are available to fit case through doorways as low as 80",Consult the factory for details. 1/17/18 Specifications are subject to change without notice. Case designed to operate in an ambient temperature of 75"F and relative humidity of 55%or lower. Zero Zone,Inc. 1 110 N Oakridge Drive I North Prairie,WI 53153-9792 O Gus Ni ht- Toll Free:800-247-4496 1 Fax:262-392-6450 NSF www.zero-zone.com ©2018 Zero Zone,Inc. Intertek Condensate Removal and Evaporation System Specs PHYSICAL DATA Gallons Per Hour at 10' Pumps-63-0255 77777 90 Pumps-63-0483 12 Evap Pan Both applications include an outlet. Notes 1. A condensate collection and removal system includes a collection pan,pump,float switch,condensate evaporation pan with heater element and connecting tubing. 2. When used on remote cases,a 15 amp dedicated circuit(outlet)is required for evaporation pan. _ Pump-63-0255 Length Width Height 23 5/8 'Dimensions for Pump Assem- bly displayed as shipped. TL Listed Pump-63-0483 Length Width Height 7 5/8" 31/8" 5118" 'Float switch and check valve on pump 'UL Listed Evap Pan Length Width Height {I�iuu� 21" 13" 65I8" �� sssl 'UL Recognized �s I I Jr,III r. Jv I 1/12/15 Specifications are subject to change without notice. CSS-71-B Zero Zone,Inc. 1 110 N Oakridge Drive I North Prairie,WI 53153-9792 E O L U T I O N Tall Free:800-247-4496 1 Fax:262-392-6450 Zero-Zone.com ©2015 Zero Zone,Inc. Gainesville (352)376-5221 Newberry (352)4724001 -4 Fax (352)4724006 *, 11 SAMS P.O.Box 125 0 Newberry,F1 32669 Date: 12/12/2018 City of Zephyrhills Building Division 5335 8th Street Zephyrhills, FL 33542 RE: Mechanical Refrigeration Permit Dollar General Store 5931 Gall Blvd. Zephyrhills, FL 33541 Please be advised that 1,Steven M. Nadler,qualifier for Southern Air Mechanical Services, LLC do hereby ct as age n grant authorization for NICKOLAS BIERER t '7 ton my behalf in registering my license and securing the above referenced permit. even M. N&dlerU-" Southern Air Mechanical Services, Inc. License#CAC050395 COUNTY OF Gilchrist STATE OF Florida Sworn to and subscribed before me by Steven M.Nadler,who is personally known to me,this ti day of ,beee,&4-&- 2018 Notary's Signature:_ SEAL: 4W Pck Notary Public state of Florida Lisa M Davis My Commission GG 278362 OF Expires 12/0612022 SOUTHERN AR MECHANICAL SERVICES �= o City of Zephyrhills BUILDING PLAN REVIEW COMMENTS CCs Contractor/Homeowner: V�C� � �(�''�- AekU1'Caq0 Date Received: Z" Site: S-( 3 1 G A-` Permit Type: Approved w/no comments. Approved w/the below comments: ❑ Denied w/the below comments: ❑ This comment sheet shall be kept with the permit and/or plans. /,�/w - JAN 0 82019 Kalvin Sw' zV—P s Examiner Date Contractor and/or Homeowner (Required when comments are present)