Loading...
HomeMy WebLinkAbout18-20356 CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 20356 FIRE ALARM SYSTEM PERMIT PERMIT INFORMATION LOCATION-INFORMATION Permit Number: 20356 Address: 40119 CR 54 Permit Type: FIRE ALARM SYSTEM - ZEPHYRHILLS, FL. Class of Work: FIRE ALARM SYSTEM Township: Range: Book: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Square Feet: Subdivision: CITY OF ZEPHYRHILLS Est. Value: Parcel Number: 06-26-22-0000-01500-0020 Improv. Cost: 1,590.00 OWNER INFORMATION Date Issued: 10/23/2018 Name: STAHL FAMILY FARMS LLC Total Fees: 150.00 Address: PO BOX 550 Amount Paid: 150.00 JANE LEW, WV. 26378-0550 Date Paid: 10/23/2018 Phone: Work Desc: FIRE ALARM CELLULAR COMMUNICATOR INSTALLATION- OFFICE CONTRACTORS APPLICATION FEES COMMERCIAL FIRE&COMMUNICATIONS FIRE ALARM 50.00 FIRE PLAN REVIEW FEES 50.00 FIRE INSPECTION FEES 50.00 FIRE ACCEPTANCE Final Ins ections Required FIRE ELEVATOR RECALL Chapter 633, Florida Statutes,authorizes the City to charge and collect user fees to pay for the costs of fire prevention and protection related activities such as inspections, plan review,administrative fees,and other costs related to the aforementioned. Complete Plans, Specifications and Fee Must Accompany Application. Commencement of work without written approval of the Fire Department's Fire Marshal or required permits or opening up for commercial activity without an approved final inspection shall be charged double permit fee per day of operation or a minimum of$100.00, whichever is greater. All work shall be performed in accordance with City Codes and Ordinances. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMME MENT " CONTRACTOR SIGNATURE PERMIT OFFIC PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOURS NOTICE REQUIRED ZEPHYRHILLS FIRE RESCUE DEPT- 813-780-0041 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received —� --C Phone Contact for Permitting 727 ing 530 _ 4521 EXT. 1021 Owner's Name STAHL FAMILY FARMS LLC Owner Phone Number Owner's Address I PO BOX 550, JANE LEW WV 2 63 7 8-0 5 5 Q)wner Phone Number Fee Simple Titleholder Name I N/A Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS 40119 COUNTY ROAD 54, ZEPHYRHILLS, FL 33540 LOT# SUBDIVISION PARCEL ID# 06-26-22-0000-01500-0020 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED a NEW CONSTR e ADD/ALT = SIGN = = DEMOLISH INSTALL REPAIR PROPOSED USE = SFR COMM = OTHER TYPE OF CONSTRUCTION = BLOCK = FRAME E DESCRIPTION OF WORK Install cellular commun'cato Office Bdlg. BUILDING SIZE SQ FOOTAGE HEIGHT =BUILDING $ 1,590.00 VALUATION OF TOTAL CONSTRUCTION =ELECTRICAL $ AMP SERVICE = PROGRESS ENERGY = W.R.E.C. =PLUMBING $ =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION =GAS = ROOFING = SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO I BUILDER COMPANY SIGNATURE REGISTERED I Y/ N FEE CURREN Y/N Address � License# ELECTRICIAN COMPANY SIGNATURE 1,Y/ N FEE CURREN Y/N Address License# PLUMBER COMPANY SIGNATURE REGISTERED I Y/ N I FEE CURREN Y/N Address License# MECHANICAL COMPANY SIGNATURE REGISTERED I Y/ N FEE CURREN I Y/N Address I License# OTHER �,) COMPANY Commercial Fire & Communicatio s SIGNATURE U/ REGISTERED Y,4 N FEE CURREN, Address 16333 Bay Vista Dr. , Clearwate License# EF20001347 RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster,Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ****PROPERTY SURVEY required for all NEW construction. Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500) Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE"COVNftRrPERMI*l11G '(copy of contract.required) Reroofs 1f shingles ` Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public'roadways..needs ROW ;3 NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work,they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the"contractor Block"of this application for which they will be responsible. If you, as the owner sign as the contractor,that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use in existing buildings,or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands,that such fees, as may be due,will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a"certificate of occupancy'or final power release. If the project does not involve a certificate of occupancy or final power release,the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended): If valuation of work is$2,500.00 or more,I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner",I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner"prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction,zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. Army Corps of Engineers-Seawalls,Docks,Navigable Waterways. Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. US Environmental Protection Agency-Asbestos abatement. Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone'V"unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a .,compensating volume"will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction,I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties,the owner may be cited for violating the conditions of the building permit issued under the attached permit application, for lots less than one (1) acre which are elevated by fill,an engineered drainage plan is required. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate,cancel,alter,or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans,construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced. An extension may be requested, in writing,from the Building Official for a period not to exceed ninety(90)days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. FLORIDA JURAT(F.S.117.03) OWNER OR AGENT CONTRACTOR Subscribed and sworn to(or affirmed)before me this Subscribed and sworn to(o ffirmed)before me is by 0CfVLM;2C' by 11aHC�2_T �CC9�/G� Who is/are personally known to me or has/have produced Who is/are personally knovM to me or has/hav6 produced as identification. (/ as identification. Notary Public `lXti( C�R�r w Notary Public Commission No. Commission No. Name of Notary typed,printed or stamped Name of Notary typed, intecl.orstatnped KELLY K.WILLIAMS ruv,Y:•. Notary Public-State of Florij:t Commission N GG 112233 My Comm.Expires Jan 5,2022 Banded through National Notary Assn. uconioJ City of Zephyrhills BUILDING PLAN REVIEW;COMMENTS Contractor/Homeowner: Date Received: /k`'G Site: YO&F C6Y Permit Type: Approved w/no comments: Approved w/the below comments: ❑ Denied w/the below comments: ❑ This comment sheet shall be kept with the permit and/or plans. Gene Brown—Fire Safety Officer a e Contractor and/or Homeowner (Required when comments are present) w ZEPHYRHILLS FIRE DEPARTMENT. '. 38410 6th Ave,Zephyrhillsi FL: 33542 FIRE.SERVICE.USEREEES• . increase 1/1/2018 Occupancy No.:. �.. Plan No::: Contractor: Business.Name: iJ A- . _ . ' 'Poo. Billing Address: . . Business Address: a 1 o t 1 e/L: :o �cc� Business.Phone No.: Billing'Phone NO,: Business.Fax No.: Billing Fax No.: :Contact: . Contact:: :RPLAN INSPECTIONTEES _ PERMIT FEE ' Annual-' . . Education,healthcare,De . . tention&Correctional Public Assembly;Business, schools,. : Storage,Mercantile and Churches Slte Plan N/C. Industrial. no charge Sprinkler. $50 Multi-Family/Commercial. ..03 sf : up to 800 sq,ft . . .. $. .-24.00 . . Standpipes $50 (Minimum Charge$24:00- 801 -.1,500 sq ft: $ 34.52 Fire Pump $50 1J Plan Revisions DBL. _ 1,501-2,500 sq ft : $ 60.02: Hoods�$50 2,501-3,500 sq ft -: $ :: 90.02 Fire AlSPRINKLER.SYSTEMS 3,501-5;000 sq ft $- .127.52. 0-25 Heads $50 5,501-7,500 sq ft $.. :187.52. Natural.Gas $50. B� 26 plus Heads.' $100' 7,501=10,000 st ft $ ..262:52 . Fuel.Tanks= per tank° $50 STANDPIPE SYSTEM 10,001=15,000 sq ft. :$ . 375.02 Sparklers voo •Per Riser .'.'$50 15,001.-20,000 sq ft.' $', 525.02 Fire Works $500 FIRE PUMP•. . 20,001=30,000 sq ft_ '$. 750.02 Camp Fire(recreation: .$25 . Per Pump. $100 30,001-40,000 sq ft $ .1'.050.02. Controlled Bum(15da; $100 . FIRCE AL YSTE 40,001=60,000 sq ft $:1,500,02 Hood/Duct $50 0,- S,..De Ices 50 60,001-80,000 sq.ft $ 2;100.02 Place of Assembly . ,.$50 Annual 80,001-42,100:02)per. : 6. 26 plus Devices $100 ea add 1,000sq ft' $ . 0.06 Fire Protection. $25 SUPPRESSION SYSTEMS (Business'closed until FlammableAppliCation:` .$50 Annual Wet $50. ' violations corrected) Waste Tire Storage $50 Annual Dry. $50: : .SPRINKLER SYSTEMS: : Generator<KW $100. C,02 $50 Hydro:Undergrounds $45 Generator>30 KW $100 Other :$50. Hydrostatic Test. - 165. Per.system. Bio-Hazard Waste, $100:Annual KITCHEN EXHAUST: Acceptance Test. $45. per system Fumigation Tenting $50 0 Hood/Ducts $50 Hydrant Flow $75 Torch Pot/Applied $50 OTHER �_ . : Haz.Materials. $5.0. :Annual LP Installation pertank $50 FIRE ALARM SYST Fuel-Tank.Installation $5 . System Acceptance . .. . (Peffarlk) $50' . .Reca ance. $50 Natural Gas Installation '. $50' OTHER (Per.System)• Fire WaIl/Smoke Wall $15 per.walP Spray Booth . $50. LP Gas: .$25. pertank Natural Gas $25 per system Tent.10'x10'or.greater $15 pertent Fire Pump . . '.$45 Fire:-Suppression. $30 System Acceptance- .Exhaust Hood/Duct $30 Re-inspection, DBL . {other than annual) .. Inspection scheduled DBL and cancelled less than 24 hours . Construction Insp., N/G Emergency Vehicle Acce -$50 PLANS TOTAL : : s�� INSPECTION TOTAL .{a . PERMIT TOTAL ,S o . . . :GRAND:TOTAL: Comments: . . . . . . . . . . . . Date;. . id Ins ector: p . . . see back nm FALSE"ALARM FEE 1st Alarm N/C 2nd Alarm N/C. : 3rd Alarm N/C 4th Alarm $100 5th Alarm. $150 6th Alarm $200 NON COMPLIANCE $150 Cont.Annual.Inspection Fees. ' 3-11 Units price per unit $ . 5.36. 12-25 Units price;per unit $: 4.82 26-50 Units price per unit $ 4.29 51A00 Units price,per unit, . $ . 3.75 . 100 or more Units price per unit' $ 2:68. Fire Safety re-inspection types First Re-inspectiol N/C . Second re-inspect $75: : Third re-inspectior $ 125.00 Inspection scheduled but cancelled 24"hrs $ 50A0 TOTAL AIh Commercial FIRE y y & Communications,ine. 16333 Bay Vista Dr. P.O. Box 1350 Phone(727) 530-4521 Clearwater, FL 33760 Largo, FL 33779-1350 Fax(727) 531-0596 9.27.2018 To: City of Zephyrhills — Construction Services Attn: Fire Alarm Plans Review Re: Latham Pool Products 40119 County Road 54 E. -Office Bldg. Zephyrhills, FL 33540 -Fire Alarm Cellular Communicator Installation SCOPE OF WORK Installing new Fire Alarm Cellular Communicator for the existing Silent Knight SK5208 Fire Alarm Control Panel: • Communicator connects directly to the Fire Alarm Panel DACT. • All existing field devices/appliances are compatible and to remain as is. • Cellular Communicator is connected to existing 120vac/20A Dedicated Circuit, w/Surge Suppression. • System is monitored and reports to Central Station. The Fire alarm installation shall comply with the following codes: - Florida Fire Prevention Code (6t" Edition - 2017) - NFPA 70 (2014 Edition) - NFPA 72 (2013 Edition) Complete system function(s) test shall be performed upon completion. Please see attached: - Equipment specification sheets - Battery Calculations Respectfully, Darkees Malcolm Engineering Dept. 727-530-4521 (ext.1021) da rkeesm0bcfcsystems.com Full Service Alarm&Communications Contractor License#EF20001347 Commercial FIRE y y & Communications,Inc. 16333 Bay Vista Dr. P.O. Box 1350 Phone(727) 530-4521 Clearwater, FL 33760 Largo, FL 33779-1350 Fax(727) 531-0596 Latham Pool Products 40119 County Road 54 E. -Office Bldg. Zephyrhills, FL 33540 Fire Alarm Equipment Submittal Description Manufacturer Part# Control Panel (existing) Silent Knight 5208 Cellular Communicator Napco SLE-CDMA-FBPS Full Service Alarm& Communications Contractor License#EF20001347 ALARMFIRE CONTROL PANEL SILENT Model 5208 KNIGHT Fire Alarm Control Panel by Honeywell with Digital Communicator The Fire Alarm Control Designed to Grow with Your Systems Needs, Without The Growing Pains. The SK-5208 is a microprocessor based control panel with built-in UL listed communicator designed for applications requiring smoke detection, manual pull stations, and sprinkler supervision. It features an easy to read LCD display with programmable English readout and user friendly tactile keys. The basic unit offers 10 zones of initiation and is expandable up to 30 zones for larger applications. The SK-5208 has a complete line of supervised accessories that provide remote annunciation, auxiliary control zone expansion. Ideal for new and retrofit applications, the SK-5208 delivers the performance to handle your installation. Features Built-in synchronization for • 10 zones, 8 Class B (Style B)and 2 appliances from AMSECO@, Class A(Style D)or Class B (Style Gentex®, Faraday, System Sensor®, B)zones, expandable to 30 zones and Wheelock® • Supervised zone expanders and 1/0 Programmable date settings for modules can be mounted remotely Daylight Saving Time from the main control panel Clock source setting options for 50 • Event History Buffer(150 events) Hz, 60 Hz, or internal (uses the with date/time stamp panel's internal clock) • All zones are compatible with 2-or Specifications 4-wire detectors • 8 selectable/programmable output Operating Voltage: 24 VDC patterns for notification appliance Primary AC: 120 Vrms @ 60Hz, 2A circuits Total DC Load: 6 Amp • Built-in Digital Alarm Communicator Current Draw: Transmitter(DACT) Standby: 140 mA • 4 Notification Appliance Circuits Alarm: 460 mA • 4 programmable general purpose Flush Mounting Dimensions: relays Height: 24.75" (62.9 cm) • Programmable smoke verification, Width: 14.5" (36.8 cm) pre-alarm delay, cross zoning and Depth: 3-7/16" (8.73 cm) enhanced verification mode features with 5/8"protruding that can help minimize false alarms Overall Dimensions: SK-5208 • Programmable from the built-in Height: 26-3/8"(67 cm) . Plex-2 Door Option control panel touchpad, remote Width: 17-3/16"(43.66 cm) . SK-SCK Seismic Compliance Kit annunciator, or Windows@ SKSS Total Depth: 4"(10.16 cm) downloading software Operating Temp: 32°to 120° F Listings and Approvals • Direct connect port for on-site (0'to 49' C) • UL Listed up/downloading with Windows® Humidity: 10-93% noncondensing • CSFM Listed SKSS downloading software • MEA approval 429-92-E Vol.XIII • Built-in walk test feature Optional Accessories • OSHPD (CA)OSP-0065-10 • Single or dual interlock water SK-5235 LCD Remote Annunciator releasing capability SK-5217 10 Zone Expander • Plex door option combines a dead (2 max. per system) front cabinet door with a clear SK-5280 Status Display Module(8 window, limiting access to the panel max. per system) while providing single button 5220 Direct Connect Module operation of the reset and silence 5824 Serial/Parallel Printer Interface functions Module • Programmable AC trouble relay SKSS Downloading Software FIRE ALARM CONTROL PANEL Model 5208 Fire Alarm Control Panel with Digital Communicator Engineering Specification The system shall contain a fire alarm control panel to supervise and operate heat and smoke detection devices, manual fire alarm devices, alarm notification devices and visual annunciators. The system shall also be capable of monitoring for sprinkler supervisory and water flow conditions. The system must have a built in UL listed fire communicator that can be enabled/disabled as needed on a per job basis. In addition, the system will sound alarms locally for purpose of evacuation. Telephone Line 1 Telephone Line 2 Direct Connect ----------- - : -.-.... ---- —-- - I - _ For On Site Programming 2 Class A (Style D) v 1 or Class B (Style B) -- Initiation Circuits Programmable Form C Relays 8 Class B (Style B) Notification Initiation Circuits J ® �;;', Appliance Circuits 0 5235 Remote E 2 r I Annunciators I, a - �� SBUS Devices 5280, 5217, & 5824 To AC This document is not intended to be used for installation purposes.We try to MADE IN AMERICA SILENT keep our product information up-to-date and accurate.We cannot cover all KNIGHT specific applications or anticipate all requirements.All specifications are FORM#350318 Rev E subject to change without notice.For more information,contact Silent Knight ©2013 Honeywell International Inc. by Honeywell 12 Clintonville Road,Northford,CT 06472-1610 Phone:(800)328-0103, Fax:(203)484-7118. For Technical support, Please call 800-446-6444. www.slientknight.com ' — ' � Commercial F^re Alarm Communicators:�StarLInk F*ire. ' COMMERCIAL FIRE CELLULAR&|P Sole & Dual Path Cellular Wor UP ° Universal full event sole path cellular&dual path UL andNFPA FireCode-Compliant,the StarLink Series cellular WorUP commercial fire alarm ��� �m�����|R�N�����&�|�� any panel bran���ua|���mm anywhere ' Communicators |suppmt�ranyb�nd1ZV ' - 1o24Vfire alarm control panel, ° For use asp�mnary or backup mmmnnnomhcatmnsmnall VV�hb broadest 'footprintreporting U } inVerbon Network 12V'24Vcontrol panels and FACPs that communicate using [ertifiedTm CDMAor GSM 3/4G models on the AT&T network, Contact|D and 4/2(such ason legacy panels) as well as mercantile models,all provide the most economical ° Reports toany Central Station nationwide,via dial upor\P solution and for easy,versatile installation. Safeguard Accounts&Reliability.For applications currently ° Communicate critical life and safety alarm reports on relying upon quickly-disappearing uadid phone o aiUne� cyber'protectadmno|tibO|ion'doOarceOu|arnationm,ide �arLinkvvire| ss communicators anbeused for—` hmary reliable networks,Vehzon Network[erdDedor/(T8Q,for or backup communicadon�and v�U �safeguard 'not ndthe nnaxinnunn security&liability protection fire alarm reporting transmissions for the future,but provide ° 6a��flexible installation,e���m���mw J&mo0�ea�com�� theend'u�erm»nth|ysavin�sforeach cost�FA[p'dedioated ' |andUne they nep|ace And,for |d wireless� management � arm communicators on 2G and other phased-out cellular ° Cost-saving models and plans for any code requirement. networks,all Storl-(nk Fire radios,offer a$1OOtnadeupincentive Substantial savings over nnonthk/dedicated|and|�'echarges. to help def�Ythe cost»f the hardware replacement tuthe And, $1OU saving incendvefor ' tennupgnedes— nno!d advanced gate'of-the'artStarLink model ofchoice. radios(all makes)and old POTs|andUnes,as well asnew Flexible Performance&Reporting Options.StarLinkRne installations provides full data reporting,in sole and dual path,asaprimary or backup, requiring any special equipment on premises. Ultra-affordable plans are available to meet various codes and requirements, with supery'isory check-ins from 200 seconds,to 5-minutes, toanhour. The units are very easily activated,plans and options are selected,and 24/7 account management is provided all through www.napcocomnet.com.And,StarLink Fire Communicators are easily connected to any panel or Fire Alarm Control Panel(FACP)standardly operating between 12V and 24V. Flexible in any application, StarLink Fire also comes in standard,or Mercantile A, Models in metal housings,with code-compliant supervision,with or without using conduit,and choice of power options, powered by the panel or using its own 120V Power Code-compliont standard or mercontile metol models(right and left,respectivel Napco Starl-ink Universal Fire Alarm Communicators \~~~— ^ Sole Path Cellular and Dual Path Cellular 8/or|PModels " Bonus:Full -r~ ''H|�h High-Speed apco Panel renmote wsnwonx " Choice wf plans(varies by model)'check-ins from 2OO oplmading/domn|padin8 »e*nnso seconds,to5'minutesto1 hour,YerizonorAT&T , COMPLIANCES:NFP/72 Editions:2016'2O13'2O10'ZOO7; " Patented Signal Boost-signal ampU �amplification circuit ��nd UL8� 9thEd,UL161[,ULgO5,UL1O23 NY[FD;[3R0 high-gain performance antenna for longer range and reliability nationwide ��J� ��� 0�������m�� ����m��.0��������� NFmX " Money-saving Tradeup incentive credit COMMERCIAL spim�2 AAL _Stadink Fire Specifications Ordering Information STANDARD MODELS: COMMERCIAL FIRE SOLE PATH CELLULAR& • Durable ABS plastic housing includes three keyhole slots for DUAL PATH CELLULAR&/OR IP(•'I"MODELS):* mounting(for commercial application,aligns with triple gang SLE-CDMA-FIRE Standard ABS (Red)Fire Sole Path Alarm boxes.) Communicator,Cellular CDMA,Verizon-Network Certified • Dimensions:5-3/8"x7-7/8"x 1-7/8"(HxWxD) SLE-CDMAI-FIRE as above,Dual Path Alarm Communicator, • Weight:13.5 oz Cellular&/or IP(primary or backup,selectable) • 3 LED Indicators-Green,Signal Strength;Amber-Busy/ SLECDMA-CFB-PS Commercial Fire Mercantile model in red Activation;Red-Trouble metal housing,CDMA,Verizon-Network Certified. Direct • Patented Signal Boost'"signal amplification circuit and high- 120VAC Powered(w/provisions for backup battery/charger). gain performance antenna Or,Optional TRF12 plug-in transformer may be used,where • Operating Environment:0 to 490 C(32-1201F),up to 93% codes permit humidity(non-condensing) SLECDMA-CFB Commercial Fire Mercantile model in red metal • 12V-24V Universal FACP Support,auto-current sensing. housing on CDMA,Verizon-Network Certified Powered directly Support all brands communicating in Contact ID and 4/2 from control panel • Powered by Panel,Low current draw,71 mA standby,200mA Note:Substitute prefix SLE3/4G-"on any models above for transmit AT&T314G Network MERCANTILE MODELS(similar to above,with): ACCESSORIES: • Locking Metal Enclosure with Hinged door& 2 key-slots for SLE-DLEXT Optional,as above,for downloading,extends distance wall mounting(LED indicators,inside). to Napco panel up to 100' • Dimensions: 9-5/8"x l l-3/4"x 3-3/8"D(HxWxD) TRF12 Optional Plug in AC Transformer,16.5V/20VA(use is • Weight:8 Ibs(max.,power supply models) subject to local code compliance) • Electrical Ratings for 120VAC,60Hz SLE-DLCBL Optional High-Speed Napco Panel Up/download cable • For Models with Power Supply: Also Available:StarLink Intrusion Radios in • Input Voltage: 120VAC Nominal standard and mercantile versions • Input Current:400mA maximum SLE-GSM-3/4G Standard Burglary • Maximum Charging Current: 200mA Radio(Black),GSM 3/4G on AT&T • Electrical Ratings for+12V Network powered by panel. • as above,but CDMA For Models without Power Supply:pP y: communications,Verizon-Network • Input Voltage: 11-15VDC(power-limited output from listed Certified. Control panel) SLECDMA-CB Commercial Burglary • Input Current:71 mA with peak RF transmission current of CDMA Radio,Verizon Certified,in p p white metal housing.Powered directly 200mA. from control panel. • Electrical Ratings for the IN 1 Burg/Fire Input: f e SLE3/4G-CB as above,but GSM 3/4G • on AT&T Network. In ut Volta e;9 15VDC I Starj +!t� p g -"�`' SLE3/4G-CB-TF commercial Burglary • Maximum Input Current:Up to 2mA from FACP NAC circuit CDMA,Verizon Certified in white • Electrical Ratings for IN 2 and IN 3: metal housing with power supply powered by plug-in 16.5V/20VA • Maximum Loop Voltage:15VDC transformer&provision for battery. • Maximum Loop Current: 1.2mA • Electrical Ratings for 3 PGM Outputs: • NETWORK O en Collector Outputs: Maximum voltage 3V when active; NE 1 V maximum when not active g StarLInk Fire. CETWORK ED • Maximum PGM Sink Current:50mA mount. COMMERCIAL FIRE CELLULAR&IP • Operating Environment 0 to 49°C(32-1200F),up to 93% humidity(non-condensing) 333 800-6 5-944 -Fax:1-6 1- 11-92 2 1-800-645-9445 •Fax:1-631-789-929SA 2 � • 12V-24V Universal FACP Support,auto-current sensing. www.napcosecurity.com Support all brands communicating in Contact ID and 4/2. HFPA COMPLIANCES:NFPA 72 Editions:2016,2013,2010,2007; UL 864,9th Ed.,UL1610,UL985,UL1023;NYCFD;CSFM *StarLink Fire are also rated to support Intrusion/Burglary alarm reports where applicable.Starl-ink'and Signal Boost are trademarks of NAPCO.Pats,Pending.Specifications subject to change. ©NAPCO,NAPCO Security Technologies Inc.(NASDAQ:N55c) A676F 2017.1 \_\ *Verizon and Verizon Network Certified, UL,AT&T and other trademarks,are trademarks of their respective companies,and are unaffiliated with NAPCO. `'�, n StarLinkTM SLE Commercial Series NAPCO°333 w Avenue Amityville Ne New York 11701 Alarm Communicators For Sales and Repairs,(80ily' 51 1 INSTALLATION INSTRUCTIONS For Technical Service,(800)845-9440 or visit us at h Ito:llfech.naoeosee urilv.eoml (Note:Technical Service Is for seeurily professlonals only) _ Publicly traded on NASDAQ Symbol:NSSC ©NAPCO 2017 WI2145BI //17 INTRODUCTION For Commercial Burglary installations, under the armed The StarLink' Commercial / Residential Fire and Burglary condition, any loss of communication must be treated alarm capture radio communicators are fully supervised, as a Burglary Alarm at the Central Station. wireless digital two-way subscriber units supported by an The following models are available: extensive nationwide wireless network. All models are SLE3/4G-CFB-PS: Commercial / Residential Fire and compatible with most 12VDC alarm control panels (always Burglary GSM 3/4G Radio in red metal housing with SLE- adhere to the documentation provided by the control panel ULPS-R power supply and 16.5V / 20VA transformer manufacturer). Models SLE3/4G-CFB and SLECDMA- mounted inside housing CFB are compatible with most 12 or 24VDC control SLE3/4G-CB-TF: Commercial / Residential Burglary and panels. All can function as a.backup to existing telephone Residential Fire GSM 3/4G Radio in white metal housing lines, or as sole path primary communicators. In backup with SLE-ULPS-R power supply and TRF12/T123 plug-in mode, all units will automatically switch the communication 16.5V/20VA transformer channel from the telephone line to the network when tele- SLE3/4G-CFB: Commercial / Residential Fire and Bur- phone line trouble is detected. See W12140 for program- glary GSM 3/4G Radio in red metal housing. Powered ming information. directly from control panel (no power supply, no trans- The SLE Series radios use data-capture technology that former, rated 12/24VDC input) captures the alarm report from the control panel and trans- SLE3/4G-CB: Commercial / Residential Burglary and mits the alarm signals to the SLE Control Center; the alarm Residential Fire GSM 3/4G Radio in white metal housing. signals are then forwarded to ANY central station via Con- Powered directly from control panel (no power supply, no tact ID or Sur-Gard System II via TCP/IP using standard transformer) line security. The SLE Control Center reports a trouble SLECDMA-CFB-PS: Commercial / Residential Fire and signal in the event that the network does not receive the BurglaIry{CDMA Radio in red metal housing with SLE- expected supervision signal from the wireless communica- ULPS-R power supply and 16.5V / 20VA transformer tor. mounted inside housing SLECDMA-CB-TF: Commercial / Residential Burglary STARLINK RADIO REPORTING PATH and Residential Fire CDMA Radio in white metal housing The diagram below shows the transmission path of a with SLE-ULPS-R power supply and TRF12/T123 plug-in signal from the StarLink radio to the central station. 16.5V/20VA transformer 1. Signal from a Control Panel. SLECDMA-CFB: Commercial / Residential Fire and Bur- 2. StarLink radio receives the signal transmission glary CDMA Radio in red metal housing. Powered direct- (from the TIP an. RING wires); sends RF signal ly from control panel (no power supply, no transformer, through the GPRS network operator. rated 12/24VDC input) 3. Network Operator, part of the vendor system, a SLECDMA-CB: Commercial / Residential Burglary and section of the cellular spectrum. Residential Fire CDMA Radio in white metal housing. 4. SLE Control Center, receives and routes data. Powered directly from control panel (no power supply, no 5. Central Station. transformer) The following features are included with models that include )r4 a SLE-ULPS-R power supply: �`- • Power limited output to the Starl-ink radio PC board 12V input terminals StarLlnk' • Battery connection red and black flying leads Radlo • Monitored battery charging and Active battery test circuits a (2) Control (3) AGENCY LISTINGS Panel (1) • UL 864 Standard For Control Units and Accessories For Fire Network Alarm Systems, 10th Edition Operator UL . UL 1610 Standard For Central-Station Burglar-Alarm Units • UL 985 Standard For Household Fire Warning System Units 111III • UL 1023 Standard For Household Burglar-Alarm.System Units • Commercial Fire Radios CSFM Listed and NYCFD COA 4 #6213 CENTRAL (5) STATION UL Classified StarLink Network CDMA models are Verizone Network Certified Operations Center 3/4G models are AT&T Network Certified • StarLink radio trouble input (from StarLink radio PC 3/4G radios where an External Antenna needs to be in- board PGM1 terminal to detect StarLink radio trouble) stalled outside of the room in which the radio is installed • Requires a sealed lead acid min 4AH /max 7AH battery (maximum 30 meters in Residential applications), please for minimum 24-hour standby time (max charge current use RF Transmitter Board 9GPS53320EXAPSLD availa- 200mA). ble from our Customer Service Department, if not provid- • Trouble relay output (C, N/O and N/C terminals) to ed. The 9GPS53320EXAPSLD is identified by "two red wire to a panel zone dedicated to "GSM Trouble" (dry dots" located on the lower right corner of the board. See contacts). Remove jumper"J2" to isolate common from WI2222 included with the 9GPS53320EXAPSLD for the ground simple installation procedure. • Green AC ON LED visible from the exterior housing GEM-Tamperkit - Tamper switches and screws to protect • Yellow TROUBLE LED on PC board. Flashes signify: metal housing (see page 19). One flash:AC fail/brownout(2 hour delay) Two flashes: Low battery SPECIFICATIONS Three flashes: Charging circuit trouble The following specifications apply to all StarLink radio mod- Four flashes: StarLink radio trouble els unless otherwise stated: The housing-mounted transformer (when provided) is Electrical Ratings for 120VAC, 60Hz mounted inside its own housing compartment with a re- For Models with Power Supply placeable UL Listed .5A fast blow primary fuse. 120VAC • Input Voltage: 120VAC nominal connections are to be made by a licensed electrician using • Input Current: 150mA maximum suitable connectors, in accordance with N.E.C. and local • Maximum Charging Current: 200mA code requirements. Electrical Ratings for+12V For Models without Power Supply* ADDITIONAL COMPONENTS • Input Voltage: 11-15VDC (power-limited output from In addition to the models listed above, the following sub- Listed control panel). Note: Models SLE3/4G-CFB and assemblies are available: SLECDMA-CFB are rated 11-25VDC input. SLE-ULPS-R - Power Supply. Required for installations • Input Current: 71mA with peak RF transmission current where the control panel cannot provide the 71 mA of of 200mA. Auxiliary power required to operate the StarLink radio. Electrical Ratings for the IN 1 Burg/Fire Input: Uses a standard 4AH / 12V minimum (7AH maximum) • Input Voltage: 9-15VDC. Note: Models SLE3/4G-CFB rechargeable battery to provide radio standby.power. and SLECDMA-CFB are rated 9-25VDC input. Requires connection to either the model NAPCO . Maximum Input Current: Up to 2mA from FACP NAC TRF12/T123 (16.5V/20VA)external plug-in transformer circuit or the chassis-mounted 16.5VAC / 20VA transformer Electrical Ratings for IN 2 and IN 3: affixed inside the housing (see wiring diagrams further in Maximum Loop Voltage: 15VDC. Note: Models this manual). Note: For models without the SLE-ULPS- SLE3/4G-CFB and SLECDMA-CFB are rated max R, connect the radio terminals 1 and 2 to the control 25VDC input. panel Aux Power terminals(observing polarity). SLE-DLCBL- Download Cable, 6 feet. Maximum Loop Current: 1.2mA • End of Line Resistor(EOLR)Value: 10K(2 req'd) SLE-ANTEXT - Extended antenna with 15 feet of cable Electrical Ratings for 3 PGM Outputs: (any suitable external cellular antenna is permitted by UL). Always follow the manufacturer's installation in- Open Collector Outputs: Maximum Voltage 3V when structions. Note: Antennas are not Listed by UL. For active; 15V maximum when not active. Note: Models SLE3/4G-CFB and SLECDMA-CFB are rated max NOTICE TO AUTHORITIES HAVING JURISDICTION, USERS, INSTALLERS, DEALERS, AND OTHER AFFECTED PARTIES FIRE PROGRAMMING OPTION PERMITTED IN AVAILABLE SETTINGS REQUIRED UL 864 SETTINGS UL8647(YIN) Disabled(Jumper 1 installed). Also required for Commercial/Burgla- Unattended Remote Downloading No Enable/Disable ry installations. Note: See page 8"Configuration Download/Firm- ware Updates"for jumper instructions. Unsupervised using conduit within 20 feet of FACP(default). If not IN2 and IN3 Unsupervised Yes Supervised/Unsupervised using conduit,install Jumpers 4 and 5 and EOL Resistors(see pages 3 and 4). 7 Day Supervision,Radio to NOC No 200 seconds,5 minutes,60 minutes,7 days 200 seconds,5 minutes,60 minutes 'For Commercial Fire installations,a UL Listed Fire Alarm regulated power supply or FACP regulated auxiliary output is required. 2 StarLink-SLE Commercial Series Alarm Communicators--Installation Instructions . ` , -25VOCoutpuL lechor/hig .h' when the telephone hnavoKoga is too ° Maximum PGM Sink Current 5Om/\ (up bu 15VO���. low,the output is active low. 25mAM51VD�-26VO(�) ` ' �B�: 'XN 1: Active high input for wiring to the panel ` ' ~ ' ' bell output. When this input detects o pulsing bam- Phymica( (Wx H x D) pora| 3 high � sends o Fine alarm; a pulsing tem- yNutm|| ouaing' 11��xQ}6x���C2�2»241n8Snm\ ' ' CO i sent. When ° Housing: `� ' ' ' ' pony| 4 (CO /�onn). a �ann m ae . on Mounting: Metal housing includes two keyhole ` -- ° �un n�� � ouonQ used, �haseconductors must ha run in conduit(max wmUmounUng(see measurements on page 7) -O feet ' -for Commercial Fire, and 3 feet for Raoidmn- Environmental U � a| �ina). �mnmtpo� r Burglary applications. ° Operating Temperature: O"C-4R"C(32"F- 12O,F) TB7: IN 2: See T139` below. ° Humidity: Maximum 9396Ngn-Condenming TB8: GND: Common ground terminal. ° indoor/dry location use only TB9: IN 3: Both terminals IN2 and IN 3by default are supervised end-of-line resistor inputs that can be TERMINAL DESCRIPTIONS triggered with-N/(JorN/C relay contacts. Wire the commongpoundhermin�| ��N� �enn|na|���)bothe Configure all inputs amu� outputs using the Manage- re|ayoommon. |nBurg|oryappUcaUona.wh�nu�ed mmmmt Center screen (located at oo arm/disarm s�duoinput, a |ovvindicahys ''ormed'' Looat�dodthmbo�omc�tho8t�rLinhnodiopCUoanU. tUa and a high indicates"disanned". For these inputs bm 17b*nn�no|e are described as follows: report to a central ototion, the radio must be nonfiQ- TBI; FWR (+12V) Note: K8odm|o SLE3/4G-CFB and uredvith the central station telephone number and SLECD88A~CFB are rated 12/24VDCinput. correct reporting formats and codes. See table on (Refer ho section "STEP 4: APPLY POWER") page 1O for more information. TB2: PWRGND(-) TB1$; TIP: @eeTB1 1. be|ow. (Refer bo section"STEP 4: APPLY POWER") TB1t, RING: Terminals TIP and RING: When used for TB3: PG80I (-): Open collector output. pGK41 is nor- backup reporting,the house Tip and Ring telephone ma||yon (ocdwa low). When it is triggered (for e»+ wires must be routed from the outside to these ter- ample, atroub|e is detected) it becomes open col- m|na|o. Under normal booh up conditions, these lector/high. To have a zone dedicated toanStar- terminals are internally wired tn the PANEL TIP and Link radio tnoub|e, insert one side of the end of line PANEL RING tennino|m, allowing all transmissions resistor into this PE;yN1 barmina|, and wire the other to the central station to be monitored. These wires side of the resistor to the positive terminal of the are monitored for vo|beQa such that if voltage haUu zone. below 1.5V. o Telco Line Fault trouble is detected, TB4: PGM2 : Open collector output. This output is and the GtarLinh radio applies telephone line volt- defaulted as "Fail to Communinata", and is nonno||y age to the control panel Tip and Ring OACT inter- open collector/high. When o report fails to com- connect ho the radio allowing itbo receive and trmno- municata anywhere in the communications path, the mit any alarms sent by the panel. output is active low. TB12: PANEL RING: See wiring diagrams. TB5; pGO83 (-): Open collector output. This output io TB13: PANEL TIP: See wiring diagrams. defaulted as "Telephone Line Cut". When the tele- phone line voltage is correct, the output is open col- Note: TB14-TB17no connections permitted byUL Supervised Fire Burg Input Supervised Arm Disarm Input To St rUnk To StarLink (Alarm Panel) 0 N/C Open Disarmed TBL* Alarm Closed=Armed The EOLR must be Installed and located within the control panel housing. The EOLR must be Installed and located within the control panel housing. *Reverse polarity/energized state. Stau'mk~acs Commercial Series Alarm Communicators-Installation Instructions 3 ` RED TROUBLE LED ^ Labeled "D5". this LED is located at the bottom right ofthe PC board. Operation hamofollows: ° I Blink: Low Aux Power input voltage ° 2B||nks: Battery trouble ° 3 Blinks: Alarm report Failed toCommunicate RED DIAGNOSTIC LED(Labeled"D7") ° 4 Bliobs: FlF trouble (antenna connection or cellular registration) ° 5 Blinks: Network trouble (signal unable to reach the SLE Control Center) ° 8 Blinks: Unit disabled (reporting or.00ntro| panel downloading not allowed) ° 7 Blinks: Unit was shutdown and has nofunnbone!i- YELLOW OPERATIONAL STATUS LED(Labele GREEN RF SIGNAL STRENGTH LED(Labele "D3') ty; requires a restart (full power down and full power up RED TROUBLE LED(Labeled"MF") sequence)to restore operation ° 8 Blinks: Telco Line Cut (this is not the OACTinter- connacttotherodio) RED DIAGNOSTIC LED T014: RTS (R): See TB17below. Labeled "D7". this LED is located in the middle of the PC TBIS: PANEL TX(13): See TB1Tbelow. board. One blink indicates a weak or non-existent signal TB16: PANEL RX(G): See TB17below. from the network (green LED is off). If this rod LED is {������ TG(Y): NononnmcUonoparmi�ad. blinking in any other manner, please contact technical support. LED DESCRIPTIONS The PC board contains several LED's. as follows: SUPPLYING POWER Control panels can provide power through their Auxiliary GREEN RF SIGNAL STRENGTH LED Power terminals if the available standby current io reduced by Labeled "DT'. this LED is|000bad at the lower right corner 71mA. When there is insufficient standby current due to the of the PCboard. application (such as when 24-hour standby time is required Every 30 seconds, the SburUnk radio receiver section for Fire orCO). the SLE'ULPS-R Charger Module accessory turns onand listens hothe cell tower. Depending on the must be used to charge an additional battery and to supply signal strength dmtmoted, it will blink the Signal Strength the power for the GbadLinhnudio� See VV|2131 LED from 1 bo8times, providing a signal strength indica- tor ' thad |o updated constantly and is always displayed. Refer to Coverage Table below. JUMPER DESCRIPTIONS Green LED Operation Jumper block labeled 'X5";from top bn bottom, ao detailed in Signal strength (as received by the radio) is displayed by the following table. Note: Contact |D is mkwoyn available in `this LED blinking 1 to 8 timesraoponae0na Conbact|Ohandshakam�� at o constant nobm (with � ' short delay between blink cycles). Acceptable power Jumper Block "X5" Options level is greater than or equal to -81d8m (minimum 4 Jumperblock labeled"X5"contains 5jumper terminals;from top blinks at the mounting/onmUon). (labeled"'I")to bottom(labeled"5")as follows:JumperON Jumper GREEN RIF SIGNAL STRENGTH LED Number JumperOFF RADIO RECEIVER COVERAGE TABLE Tech on site must temporarily Not permitted by UL 864 and LED Blinks 8 75 4 3 E21 412 with Checksum Pulse Format 2 40 Pulse Format 105 Backup Mode 3 Primary Mode Power -56 E-65 -91 1._95 -99 -105 (dBm) Not permitted by UL 864 and qwv�*n g a r . . . . . . . Weaker Supervised inputs. EOLR(s)re- UL 1610(UL 864 permits use of quired,see page 3 4 and 5 conduit within 20 feet of FACP in YELLOW OPERATIONAL STATUS LED Labeled ''1014''. this LED is located at the bottom right of The StarLinh SLE Series radios are compatible with any the PC board. Operation iaamfollows: Uab»d g/mmm control unit OACTcommunicat|ng contact |D or Normal Standby Condition: any 4+2 pulse format (4/2 Pulse Dialing formats such as ° Blinks ou momentarily every i0 seconds: Unit ioin Admmno S|ow, Radionica G|ovv, Silent Knight Fast, Rodi- obandby waiting for an alarm boreport. onica Fast and Universal High Speed, with 10ppe' 20ppe. Processing Alarm Conditions: and 40ppn with and without nhaokaum. either 140OHz or ° When processing mn alarm, this LED will blink variably 23ODHz handshake/Nannff). during each part of the process (dialing, handshaking, The SborLinh SLE Series radios and NOC are compatible data transmission,atc.). with the LiohadAdemoo model 885vith model 885-8 line card D/\CR or any Listed compatible DAORw|th ony4+2 4 otarLmx~SLE Commercial Series Alarm Communicators—ins tauvuunInstructions , . o pulse or contact ID-format which is specifiedtheInobala- for Central-Station Alarm Services, and UL1G41. Gtand- mcUnnafbrthe interconnected DACT/Alarm Con- ard for Installation and Classification of Residential Bup tndUnUL ' ' mlar Alarm Systems ' � Refer to VV|214O for selecting the required handshake / o. Before applying �opower,power, m sure to connect the W000ff frequency inthe N(] setup antenna. Temporarily connect power to the Star screens(as required by the control '-n-`. Link nadib froma fully charged 12V (4AH minimum) battery. DO NOT mount the radio ot this time. Pnaoa �mmn���awitchtomendanigna|. ����IU���R�"������ BACK-UP REPORTING b. PoniUontheunitinthedeeirad mounting |boeUon.vvith The�tarLinkrmdi000nfuncUonoaoprimoryw|ne|a�000m- antenna oriented vertically. The a|gno| strength is municabzr, in cases where there are no telephone lines displayed by the Green"Signal Strength LED"labeled present,when connected directly to the control panel Telco "O3" (located at the lower right corner of the PC henninm\m. For primary reporting, do NOT install jumper 3 board'. The GGK4 radio .tower signal strength may in terminal block '9K5' The StarL|nh radio can also funo` fluctuate from day to doy, therefore it is best to try to Uon as a backup to the existing telephone lines (install find o mounting location where the LED provides jumper 3in terminal block^X5"). When used aaabackup minimum mf 4 blinks. communicator and when it senses telephone line trouble, n. Once a location has-been selected based on signal theGbarLinknodioauhumnodcmUyawhohemthecomnmu»|od' coverage, permanently secure the unit using #8 don channel from the telephone line to the GpRGnetwork. screws(not supplied) in the two mounting holes. NETWORK COVERAGE '�UARNYmo�' To ensure user safety and to satisfy FCC R� e�poeunur�qu|ramontu` �hiounitmuetbein�baUadmo The StarLink radio constantly supervises the GPRS n�net- thata minimum smponeUo distance of6Uom (24") is al- primary VVh�nih� Sb�d-|nkmedioimoon�guradfor vvoyomoinboin�� bobweon -''h� mn��nnoofdhat^namitbnQ primarynmpo�|ng' and the GbnrLink radio dahe�oa |oog in device and nearby persons. Use ONLY the ��—''oUnQ an- ne�o����ge �e���ink�diomu�baoon�Qumd� - i� this �onmi ' hanna supplied by radio bm comply vx warning prompt the control panel bo announce a Telco UneCut fail- (Exception: The -�bennawith15 unetnoub|e using the Management Center screen (located ' at www.NapcoNoc.com). Note: This Telco Line Cut fail- feet ufnob|e)' ure trouble v�U NOT activate when the �ted-|nh radio io u STEP 3: WIRING(PRIMARY AND BACKUP MODES) configured for backup reporting. 22_gauge wire may be used if mounted upbo5O feet from the control pona|' and 18-gaugevvire should be used for up INSTALLATION STEPS to 100 feet.' Reference the wiring diagrams further in this STEP1: ACCOUNT REGISTRATION manual. See the section CONTROL PANEL PROGRAM- Create a new account and register specific StarLink radio K0ING further in this manual. modules at ' Accounbsand mod- For PrimmmryMode: u|ao registered vie the Internet are enabled for activation Remove jumper#3 in jumper block labeled 'X5'. The vvip xvithin24houro' ing between the control panel and the Stad-|nk radio imover STEP 2: SELECT MOUNTING LOCATION five(5)wines. as follows! The mounting location should be indoors within the protect- ° T131; PWR (+12�M Note: Models SLE3��/�-CFB and md area and selected based on RF performance. It in � are rated 12/24VOCinput. HIGHLY recommended that the installer carefully adhere to ° �E��'' P�yf����D�� the following recommendations BEFORE any wires are in- ` ' ° TB13: PANEL TIP stalled . 9TB12: PANEL RING ° Generally, high locations are best. DO NOT mount radio ° TB2: pG881 (-). Normally !ow output wired to the in basements or below grade as unpredictable Pedop of zone dedicated to monitoring the radio status. . monue may result. Sea page 13 for BEK8C-F8ZCP|yNwiring. Should be ° D[} NOT mount the radio in non-climate controlled envi- programmed onNapco control panels aoOoy-Zone. but nonmmnto (ia. attics may become extremely hot insum- be programmed to sound locally and NOT activate the mer.garages may become extremely cold inwinbsr). bell. Note: See steps^o"and^b". below. ° Avoid mounting locations within 3 feet ofAC power lines, For Backup Mode: fluorescent light fixtures, or large metal objects (air con- |nobaU jumper#3 in jumper block labeled "X5" The wiring diUoneno, metal garage dooro, etc.) as these locations between the control panel and the EtarLink radio is over have been shown bu have o detrimental effect o» signal seven(7)wires,eofollows: strength. ° A fair amount of care may bo required to mount the Star- ° TB1: PWR(+12mr13/24V) Link radio om as to achieve an optimal RF path. The ° TB2: PWR'GMD�� installer should spend oa much time me needed buobtain ° TBIO: TIP the highest signal level possible. ° TB11: RING ° For Commercial Burglary inotaUoUono, install in accord- ° TB13: PANEL TIP anoa with ULG81' Standard for Installation and C|aooifi- ° TB12; PANEL RING cation of Burglary and Holdup Alarm Systems. |nstmUa- ° TB3: PGyN1 H. Normally |ovv output wired to the UonohaU also be in accordance with UL827. Standard StarLine SLE Commercial Series Alarm Communicators-Installation Instructions 5 (+) of a zone dedicated to monitoring the radio status STARLINK RADIO RELATED EVENT (see page 13 for GEMC-F8ZCPIM wiring). Should be ID REPORT CODES Contact b programmed on Napco panels as Day Zone, but be pro- ( y default grammed to sound locally and NOT activate the bell. CONTACT ID PULSE a. Without applying power (voltage), connect to screw EVENT AREA 412 CODE ZONE# terminals TB1 (+12 or 12/24V) and TB2 (—). If the control panel Aux. Output cannot supply the neces- sary current, then you must use the SLE-ULPS-R IN 2 Panic 0 E120 992 22 Power Supply accessory with additional battery (see IN 3 Trouble 0 E300 993 F3 WI2131). For wiring connections, see the wiring dia- grams further In this manual. Law Battery/Voltage 0 E302 994 F4 b. Referencing the correct wiring diagram for the appro- Tamper Trouble 0 E341 995 F5 priate control panel (wiring diagrams are located fur- Line cut 0 E352 996 F6 ther in this manual), connect the "TELCO" control Reboot 0 E625 997 F7 panel terminals TIP and RING (DACT interconnect IN 1 Co(Carbon Monoxide) 0 E162 998 18 wiring to the radio). Do NOT connect the StarLink radio terminals TB10-13 to house telephone lines Panic Alarm' E123 (RJ31X modular plug wires, etc.). Holdup Alarm* E122 Wiring Methods Medical Alarm' E100 • Strip wire carefully to avoid exposed conductors after 24 hour Aux.Alarm* E150 installation, etc. • Use UL Listed wire, ensuring that all conductors are to be 24 hour Aux.Restore' R150 insulated for the maximum voltage of any conductor in Burg Perimeter Alarm' E131 the enclosure Burg Interior Alarm' E132 • All wiring methods must be performed in accordance with Keypad Holdup Alarm(ambush)` E121 NFPA 70,Articles 725, and 800 Keypad Panic Alarm' E123 STEP 4: APPLY POWER Keypad Emergency Alarm' E140 • The StarLink radio requires +12 or 12/24VDC. It draws Opening' E401 less than 71mA during standby, and almost 200mA dur- ing transmissions(for less than 1 second). closing' R4o1 • Attach antenna before applying power! A.C.Trouble' E301 Tel 1 Fail' E351 STEP 5: SIGNAL VERIFICATION • Verify Online: To verify that the signals have been 'Not generated by the StarLink radio. received by the Starl-ink radio GSM Network online, go to www.napconoc.com, log in with your Username and Password, enter your Company ID number and the Star- Link GSM Radio Number, then click Signal Log. IMPORTANT: Verify that the signals transmitted by the StarLink radio have been properly received by your central station before leaving the premises. SIGNALS ORIGINATED AT THE NOC NOC Originated Contact ID Alarms Event Data Initiated By Comments Sent Automatically by NOC if fail to receive any signal For Auto Enroll,uses captured telephone number, Supervisory Fail E356 A00 Zn000 from StarLink radio within Supervisory Timeout Sub ID and format. For Dealer Programmed,uses duration. entered telephone number,Sub ID and format. Manually by dealer from the Management Center Press to Send E601 A00 Zn000 Signal Log screen (located at Same comment as above. Test Signal www.napconoc.com). Sends test into CS receiv- er. Not Applicable Manually by dealer from the Management Center Press to Send N Checkins screen(located at ____ Radio Test Nothing sent to www napconoc.com). Sends a command to the CS receiver Starl-ink radio to force a check-in to the NOC. 6 StarLink'SLE Commercial Series Alarm Communicators--Installation Instructions