HomeMy WebLinkAbout18-20420 CITY OF ZEPHYRHILLS 5335-8th Street (813)780-0020 20420 ELECTRICAL PERMIT J.: . PERMIT INFORMATION � ; LOCATION INFORMATION Permit#:20420 Issued: 11/06/2018 Address: 39050 12TH AVE Permit Type: ELECTRICAL MISC ZEPHYRHILLS, FL. Class of Work: ELECTRIC SERVICE/NEW Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 27,720.00 Total Fees: 270.00 Subdivision: COLONY HEIGHTS Amount Paid: 270.00 Date Paid: 11/06/2018 Parcel Number: 12-26-21-0260-00400-0330 CONTRACTOR INFORMATION OWNER INFORMATION Name: DON WARNER ELECTRIC INC Name: PALAZZI, THOMAS & CATHERINE Addr: 12241 GARDEN LAKE CR Address: 39050 12TH AVE ODESSA, FL. 33556 ZEPHYRHILLS FL 33542-3832 Phone: (813)477-5662 Lic: Phone: 813-779-8418 Work Desc: INSTALLATION SOLAR PANELS PV SYSTEM ROOF MOUNTED APPLICATION FEES ELECTRICAL FEE 270.00 INSPE" ONS REQUIRED ROUGH ELECTRIC CONSTRUCTION POLE PRE-METEFJ \ i FINAL REINSPECTION FEES:(c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing, consult with your lender or an attorney before recording your notice of commencement." Complete Plans, Specifications and Fee Must Accompany Application. All work shall be performed in accordance with City Codes and Ordinances. . CONTRACTOR PER OFFI PERMIT PIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received Phone Contact for Permitting 727 218 9407 7-r 7-1-e--�--'--11- -- _ - -- -e-f7 e-7 Owner's Name PALAZZI THOMAS&CATHERINE Owner Phone Number 8137798418 Owner's Address 1 39050 12TH AVE,ZEPHYRHILLS FL 33542 Owner Phone Number Fee Simple Titleholder Name I Owner'Phone Number Fee Simple Titleholder Address JOB ADDRESS 39050 12TH AVE,ZEPHYRHILLS FL 33542 LOT# 33 SUBDIVISION COLONY HEIGHTS PARCEL ID# 12-26-21-0260-00400-0330 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED e NEW CONSTR B ADDIALT 0 SIGN = = DEMOLISH INSTALL REPAIR PROPOSED USE 0 SFR Q COMM = OTHER TYPE OF CONSTRUCTION = BLOCK Q FRAME = STEEL = DESCRIPTION OF WORK INSTALL ROOF MOUNTED SOLAR PV SYSTEM.13.86 KW BUILDING SIZE SCI FOOTAGE HEIGHT =BUILDING $ VALUATION OF TOTAL CONSTRUCTION X=ELECTRICAL $ 27720 AMP SERVICE PROGRESS ENERGY = W.R.E.C. =PLUMBING $ =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION =GAS ROOFING 0 SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . BUILDER COMPANY SIGNATURE REGISTERED I Y/ N FEE CURREN Y/N Address 1 License# ,� DON WARNER ELECTRIC INC ELECTRiGIATJ,,,.-.. - SIG NATGyURE �, - REGISTERED N FEE CURREN I Y/N Address 19U GARDEN LAKE CIR,ODESSA FL 33556 License# I EC13001287 PLUMBER COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Address License# MECHANICAL COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address License# OTHER COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address License# eeeeeeeeeeeeeeeteeteeeteeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal dale. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stonnwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ""PROPERTY SURVEY required for all NEW construction. Directions: FIII out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500) Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW City:of Zephyrhilis BUILDING PLAN REVIEW:COMM TS Contractor/Homeowner: R)0-4,nw Date Received: Site: Permit Type: j I6 Foe-wSrkm Approved w/no comments: Approved w/the below comments: ❑ Denied w/the below comments: ❑ This comment sheet shall be kept with the permit and/or plans. OCT ,3 1 2018 Kalv' 'Si er—Plans Examiner Date Contractor and/or Homeowner (Required when comments are present) NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work,they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as.to-what licensing requirements may apply for the intended work,they are advised to contact the Pasco County Building::Iri_spection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the"contractor Block"of this application for which they will be responsible. If you,as the owner sign as the contractor,that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACT/UTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Transportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use in existing buildings, or expansion of existing buildings, as specified in Pasco County Ordinance number 89-07 and 90-07, as amended. The undersigned also understands, that such fees,as may be due,will be identified at the time of permitting. It is further understood that Transportation Impact Fees and Resource Recovery Fees must be paid prior to receiving a"certificate of occupancy"or final power release. If the project does not involve a certificate of occupancy or final power release, the fees must be paid prior to permit issuance. Furthermore, if Pasco County Water/Sewer Impact fees are due,they must be paid prior to permit issuance in accordance with applicable Pasco County ordinances. CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as amended): If valuation of work is$2,500.00 or more,I certify that 1, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner', I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner"prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction,zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work,and that it is my responsibility to identify what actions I must take to be in compliance. Such agencies include but are not limited to: - Department of Environmental Protection-Cypress Bayheads, Wetland Areas and Environmentally Sensitive Lands,Water/Wastewater Treatment. - Southwest Florida Water Management District-Wells, Cypress Bayheads, Wetland Areas, Altering Watercourses. - Army Corps of Engineers-Seawalls,Docks,Navigable Waterways. - Department of Health & Rehabilitative Services/Environmental Health Unit-Wells, Wastewater Treatment, Septic Tanks. - US Environmental Protection Agency-Asbestos abatement. - Federal Aviation Authority-Runways. I understand that the following restrictions apply to the use of fill: - Use of fill is not allowed in Flood Zone W"unless expressly permitted. - If the fill material is to be used in Flood Zone "A", it is understood that a drainage plan addressing a "compensating volume"will be submitted at time of permitting which is prepared by a professional engineer licensed by the State of Florida. - If the fill material is to be used in Flood Zone "A" in connection with a permitted building using stem wall construction,I certify that fill will be used only to fill the area within the stem wall. - If fill material is to be used in any area, I certify that use of such fill will not adversely affect adjacent properties. If use of fill is found to adversely affect adjacent properties,the owner may be cited for violating the conditions of the building permit issued under the attached permit application,for lots less than one(1) acre which are elevated by fill,an engineered drainage plan is required. If I am the AGENT FOR THE OWNER,I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate,cancel,alter,or set aside any provisions of the technical codes,nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans,construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6)months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety(90)days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOME OF COMMENCEMENT. FLORIDA JURAT(F.S.117.03) OWNER OR AGENT "ubscdb ACT phi Subscribed and sworn to(or affirmed)before me this sworn to(or affirmed) efore me this by by Y�O t�e Who is/are personally known to me or has/have produced Who is/are personally nTc own to me or has/have produced DL as identification. DI as identification. Notary Public Notary Public Commission No. Commission No. Name of Notary typed,printed or stamped Name of Nota ed,printed or staiiped Notary Public State of Ftoncla Timothy Coffey My Commission GG 248671 a w Expires 08/15/2022 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received Phone Contact for Permitting :727 218 9407 r 1 1 i I ' - rrrrr . Owner's Name PALAZZI THOMAS&CATHERINE Owner.Phone Number 8137798418 Owner's Address 39050 12TH AVE,ZEPHYRHILLS FL 33542 Owner Phone Number Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS 39050 12TH AVE,ZEPHYRHILLS FL 33542 LOT# 33 SUBDIVISION COLONY HEIGHTS PARCEL ID# 12-26-21-0260-00400-0330 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED e NEW CONSTR B ADD/ALT 0 SIGN Q 0 DEMOLISH INSTALL REPAIR PROPOSED USE Q SFR 0 COMM = OTHER TYPE OF CONSTRUCTION = BLOCK 0 FRAME = STEEL = DESCRIPTION OF WORK INSTALL ROOF MOUNTED SOLAR PV SYSTEM.13.86 KW BUILDING SIZE SQ FOOTAGE HEIGHT BUILDING $ VALUATION OF TOTAL CONSTRUCTION X=ELECTRICAL $ 27720 AMP SERVICE = PROGRESS E GY Q W.R.E.C. /U PLUMBING $ =MECHANICAL $ VALUATION OF MECHANICAL INSTALLATIONyl�� =GAS = ROOFING Q SPECIALTY = OTHER l y\ 4:S�}y FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO BUILDER COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN I Y/N Address License# ELECTRICIAN COMPANY DON WARNER ELECTRIC INC SIGNATURE REGISTERED N FEE CURREN I Y/N Address 12241 GARDEN LAKE CIR,ODES SA FL 33556 License# I EC13001287 PLUMBER COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address License# MECHANICAL COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN I Y/N Address License# OTHER COMPANY SIGNATURE REGISTERED I Y/ N FEE CURREN Y/N Address License# Illlllllllllllllllllllllllllllllllllllll1111111111Illllllllllllllll RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new Construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ""PROPERTY SURVEY required for all NEW construction. 'It Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement Is required. (AIC upgrades over$7500) Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW GENERAL NOTES P-100054 N EQUIPMENT LIKELY TO BE WORKED UPON WHILE ENERGIZED SHALL BE INSTALLED IN LOCATIONS THAT 0TIS6FY MINIMUM WORKING CLEARANCES PER NEC CONTRACTOR SHALL USE ONLY COMPONENTS LISTED BY A NATIONALLY RECOGNIZED TESTING LABORATORY FOR THE INTENDED USE. CONTRACTOR IS RESPONSIBLE FOR FURNISHING ALL EQUIPMENT,CABLES,ADDITIONAL CONDUITS, `J ✓x RACEWAYS,AND OTHER ACCESSORIES NECESSARY W - uj FOR A COMPLETE AND OPERATIONAL PV SYSTEM. �. V f ® WHERE DC PV SOURCE OR DC PV OUTPUT CIRCUITS N ARE RUN INSIDE THE BUILDING,THEY SHALL BE �""' W t }- �- 7� CONTAINED IN METAL RACEWAYS,TYPE MC METAL- LO Lu C 4 CLAD CABLE,OR METAL ENCLOSURES FROM THE POINT V M C°�BE9 g OF PENETRATION INTO THE BUILDING TO THE FIRST w Z M Ix READILY ACCESSIBLE DISCONNECTING MEANS,PER W Q J ,q • © NEC 690.31(G). LL ALL EMT CONDUIT FITTINGS SHALL BE LISTED AS Uj L u�u 5 WEATHERPROOF FITTINGS AND INSTALLED TO ENSURE W " J A RAINTIGHT FIT.PER NEC 358.42. r. J Lu O aF ®�® Ln (N)PROPOSED ROOF-MOUNTED PHOTOVOLTAIC 0 ' "'` �•l f� (n�; O ARRAY.8:12(34°)SLOPED ROOF,47 PV MODULES Cn " U OU (SILVER FRAME),180°AZIMUTH J C7 = O Lu 0- W -1 O ®® l SITE PLAN(AERIAL VIEq %c CU� U PV-2 SCALE:1°=20' SITE PLAN DOC ID:100054-125660-1 DATE:10118118 CREATOR:S.S. REVIEWER: REVISIONS PV-2 PVMODULE P-100054 l MODULES GENERAL ELECTRICAL NOTES • OPTIMIZER REF. Qn. MnxEaxoMODEL vMAX PTc ISC IMP voc N.1P IEN3.CAEFF.OFVOC FUSE RATING UTILITY HAS24-HRUNRESTRICTEDACCESSTOALL PMwr ai souRwosmswz9sMONO 29m x6m mean e.ASA do.av 3+5V -0.Izvrcwawc) 25A 1 PHOTOVOLTAICSYSTEMCOMPONENTSLOCATEDATTHE f PM147 NVERTERS SERVICE ENTRANCE. F TV lAAKE AND MODEL ACVOLTAGE GROUND MAX OCPD RATING RATEDPOWER MAXOUTPUTCURREM MAX INPUT CURRENT MAXINPUTVOLTAGE CECWEIGHTEDEFFICIENCY 1 M14 1191N I BIN 1 295W�� 11 I SOLAR EOGESE,000OMUS xaOV UNCROWDED 60A 10,000W dx.OA 2r 0A ASOV 99.0°S 2 MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. I ISTIUNG ) I POWER OPTIMIZERS ISMINGI ISTRINGI CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS I QQ I REF. I OTY.I MODEL RATED INPUT POWER MAXOUTPUTCURRENT Mq%INPUTISC MA%GCVOLTAC-E WEIGHTED EFFICIENCY 3 SUNLIGHT RESISTANT PER NEC ARTICLE 300.6(C)(1)AND Po1�r dr sciAR EGCE P32D 3zov+ ISa n.DA dBv 9a.e% ARTICLE 310.8(D). i I I DISCONNECTS OCPDS CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE REF. Ott. AIAKE AND MODEL RATEOCURRENT MAXRATEDVOLTAGE REF. Qtt. RATED CURRENT AW(VOITAGE SUITABLE FOR USE IN WET LOCATIONS PER NEC ARTICLE SYl1 1 EATNN 00222Nn OREGUIV. 60A 24WAC F1-2 2 BOA 210VAC 4 L_ j 1 SYSTEM SUMMARY NOTES 310.8(C). m JUNCTION BOX STRING I STRING STRLNG3 QI OPTIMIZERS PROVIDE RAPID SHUTDOWN FUNCTIONALITY REQUIRED BY NEC 690.12, LLl F-ACCURRENT RANI OUTPUT CURRENT ,5A ,s4 ISA GROUNDING NOTES ~ J81 WSERIES 20 19 8 U3 RING VOLTAGE d00V COON 400V THESPECIFIED OPTIMIZER CAN BE SUBSTITUTED WITH A P370 oR P505.THESE OPTIMIZERS HAVE AN INPUT VOLTAGE WINDOW WIDE ENOUGH TO B ACCOMMODATE ME OUTPUT VOLTAGE RANGE OF THE MODULE AT THE DESIGN TEMPERATURES.HAVE AM INPUT CURRENT RATING THAT IS ABOVE ALL EQUIPMENT SHALL BE PROPERLY GROUNDED PER THE CV 2RATING CURRENT Id.BA idA s.9A THE MAX OUTPUT aRRENTOF ME NOME,AND AMAXPORVER INPUT THAT ISABOVE THE RATED POWER OUTPUT OF ME MODULE. 1 REQUIREMENTS OF NEC ARTICLES 260&690 u W WVERTERPowER ue5rv! LC7 -�� POWER 'x,615TY ®UNGROUNDED SYSTEM DCCONOUCTORS SMALL BECOLOR-COOED AS FOLLOWS.DOPOSRNE SHALL BE RED(OR MARKED RED)AMIDONEGATIVE PV MODULES SHALL BE GROUNDED TO MOUNTING RAILS w Z W M I 111o,C00W ENT 4M 6HALLBEBIACK(ORMARKEDBLACK) USING MODULE LUGS OR RACKING INTEGRATED'ERMAXDCVOLTAGEOFARRAYFIXEDBYTHEINVERTERATd00VREGARDLESSOFTEMPEMTURETHEMAXDCVOLTAGEOFMEMODULEATI•CIS 2 GROUNDING CLAMPS AS ALLOWED BY LOCAL JURISDICTION. QECIAC POWER 10,0005'! Q LL EXPECTED TO BE 42 9V(I-C-25'C)Xd1.'ZV/C•40V=42BVH Q ALL OTHER EXPOSED METAL PARTS SHALL BE GROUNDED m 2 L IL INVERTER IS NON-ISOLATED.NO OC GEC IS REQUIRED. USING UL-LISTED LAY-IN LUGS, W N J r� J I ®PoIF7T#SONNECTIgY IS ON THE SUPPLY SIDE OF SERVICE DISCONNECT.IN LOMPLUVICE W7M NEC 705.12I/0. INSTALLER SHALL CONFIRM THAT MOUNTING SYSTEM HAS — 3 BEEN EVALUATED FOR COMPLIANCE WITH UL 2703 1 N p = CONDUCTOR AND CONDUIT SCHEDULE W/ELECTRICAL CALCULATIONS "GROUNDING AND BONDING'WHEN USED WITH PROPOSED OO f3r, i I ^J - GIRRENTLA(iRYW TEMP.CCRR. CONWRFILL COM. MAXCURRENT BASE DERATED TERM. AMR- TERM VOLTAGE PVMODULE. � Q M = TYPICAL CCNOUCTOR COKDLIT GCONDUCTORSIN GCPD EGO FACTOR FACTOR CURREM (125%) AMP, AMP. TEMP.EATING TEMP.RATING LENGTH DROP CONDUIT ALL GROUNDING SYSTEM COMPONENTS SHALL BE LISTED m i"' Ff2 '- I I 10AWGFYW'INE, FREE AIR MIA NSA 6AWGBARE O.i1(56'C) 1.0 1FU '8.75A SSA 39.OSA 75'C 'AA 137FT 172% 4 FORTHEIRPURPOSE Lu Q L— 504 COPPER COPPER m W 1.• �SW1 • 2 1 IDAWGTXWK2, 0.75'OIA, 6 WA 10AWGTMl.N-2, 0.71(Sfi-C) ae I5A fe.rsa a0A 2za2A sD•C 9Da saFr Ba% IF THE EXISTING MAIN SERVICE PANEL DOES NOT HAVE H N t fi0A COPPER EMT COPPER VERIFIABLE GROUNDING ELECTRODE,IT IS THE 3 1 IOAWGMWIRE, FREE AIR MIA NIA 6AWOBAPE' 0.71(56-C) 1.0 15A 18.T5A SSA 39MA 75-C 50A 125FT 1.17% 5 _i_ s COPPER COPPER CONTRACTOR'S RESPONSIBILITY TO INSTALL A ---- 10AWG PV WIRE, 6AWG BARE ° 1 COPPER FREEAR WA WA COPPER 071(56-C) 1.0 15A 1B.75A SSA 3SOSA 75C SON 52FT Des% SUPPLEMENTAL GROUNDING ELECTRODE. (' AC SERVICEDISCONNECT 6AWGTHWNn, 0l5-DIA N-2,10AWGTHW AC SYSTEM GROUNDING ELECTRODE CONDUCTOR GEC GEC AND MAIN DIST.PANEL 5 1 COPPER Fir MA COPPS 09613a'C) 10 32A 52.M 7S4 TEA 60•C 55A 'OFT 0.17% (GEC) (2DDA MSP W1200A MSR( 6 SHALL BE A MINIMUM SIZE#8AWG WHEN INSULATED,#6AWG 6 1 6AWG MIN 2, 0.75'DIA. 2 60A%I 10AWGTWI 2, OA(3A•C) 1D 42A 52SA 75A 72A 75-C 65A 'OFT O.li% 11 AS COPPER EMT COPPER IF BARE WIRE. EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED M7'.MR ACCORDING TO NEC ARTICLE 69OA5,AND BE A MINIMUM OF 2400/120 METER 7 #1OAWG WHEN NOT EXPOSED TO DAMAGE,AND#6AWG SHALL BE USED WHEN EXPOSED TO DAMAGE GROUNDING AND BONDING CONDUCTORS,IF INSULATED, 8 SHALL BE COLOR CODED GREEN,OR MARKED GREEN IF #4AWG OR LARGER SINGLE-LINE DIAGRAM PROJECT ID:100054 DATE: 10/18/18 CREATED BY: S.S. CHECKED BY: REVISIONS SINGLE-LINE DIAGRAM PV-3 SCALE: NTS THS OOLUMENT HAS BEEN CREAM FOR THE PURPOSE OF OESCRRB THE OEBRW OFA PROPOSED PH—POWER SYSTEM NITM ENOUGH OETAA TO OENON—TE CONRtUNCE WIM ALL APPUN—E CODES ANO REODUMNB ME DOOUMSHOUL�NOT BE RELIED UPON AS A SUBS—E FOR D"_•••///�����, � FOLLDMNOMM'UFACNREA WSIRMARON NANUMS.WSTALER—WSTAMALLEOUPMENT IN ACCORDNICE IVIM NANUFACTURER RISTA ROX MMOAS.NVINNG IN TNA DOOUMEM SHOULD BE WTERPRETEO IN A WAY TUT OYERWOES THE INSTRUCNONS W NNAFMMRER WSTAWTION MANUALS I V DC RACEWAYS EACH DISCONNECTING MEANS FOR EACH DEVICE WHERE ENERGIZED, LABELING NOTES I -100054 O SEE NOTE N0.4(DC RACEWAYS) O O UNGROUNDED CIRCUITS MAY BE EXPOSED OPHOTOVOLTAIC EQUIPMENT(J81,I1) DURING SERVICE.(JB1,11) ALL PLAQUES AND SIGNAGE REQUIRED BY 2014 NEC 1 _ I AND 2015 NFPA 1 WILL BE INSTALLED AS REQUIRED. ' R WARNING I,. t WARRING�." LABELS,WARNING(5)AND MARKING SHALL COMPLY JB1-TRANSITION BOX ELECTRIdSHOCK HAZARD,DONbT.TOUBH �,.•' WITH ANSI Z535.4,WHICH REQUIRES THAT DANGER, ELECTRIC SHOCK HAZARD.THE DC MODEL NOT SPECIFIED) --TERMINALS,TERMINALS ON GIZ OTHLINE DINTH]SAND- WARNING,AND S,HEAD SIGNSER ,AND THE SAFETY ALERT • / • • °• • CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM 0 0 LOAD SIDES MAY BEENERGIZEOINTHEOPEN. 2 HEADER COLORS,LABEL.THE STANDARD ALERT 'POSITION. ARE UNGROUNDED AND MAYBE ENERORED. SYMBOL ON EACH LABEL.THE ANSI STANDARD REQUIRES A HEADING THAT IS AT LEAST 50%TALLER NEC 690.31(G)(3)AND IFC 605.11.1 NEC 690.17(E) NEC 690.35(F) THAN THE BODY TEXT,IN ACCORDANCE WITH NEC 110.21(B). 11-INVERTER LLJ 4 5 SEE NOTE NO.5(SW7) 6 AC DISCONNECT(SW7) A PERMANENT PLAQUE OR DIRECTORY SHALL BE SOLAR EDGESE10000H-US O DC DISCONNECT(11) O O INSTALLED PROVIDING THE LOCATION OF THE SERVICE U) 3 DISCONNECTING MEANS AND THE PHOTOVOLTAIC >_ N O CID O4 SYSTEM DISCONNECTING MEANS IF NOT IN THE SAME U) Lu Lo LOCATION IN ACCORDANCE WITH NEC 690.56(B). C) 9 ® • °° ® LABELS)WITH MARKING,"WARNING PHOTOVOLTAIC a-, z Lu Ch SW1-DISCONNECT / /• POWER SOURCE,"SHALL BE LOCATED AT EVERY 10 W LL Q J EATON DG222NR8 FEET OF EACH DC RACEWAY AND WITHIN ONE FOOT OF � LL OO O O EVERY TURN OR BEND AND WITHIN ONE FOOT ABOVE _ 5 6 7 8 NEC690.53 NEC690.56(C)AND IFC605.11.1 NEC690.54 pS�MgLOIESAWALLSANDBIARRIERSR�HE/LA EILSHALL a' � � J ANY AC ELECTRICAL PANEL THAT IS FED BY HAVE 318'TALL LETTERS AND BE REFLECTIVE WITH 7 BOTH THE UTILITY AND THE PHOTOVOLTAIC 8 AC SOLAR DISCONNECT(SW1) WHITE TEXT ON A RED BACKGROUND Q O = �07 TY METER O N SYSTEM(SW7,UTILITY METER)_ LABEL(5)WITH MARKING,'PHOTOVOLTAIC SYSTEM N O >_ _ .: EQUIPPED WITH RAPID SHUTDOWN'SHALL BE LOCATED Q'' .y�",N�,' , G AT POINT-OF-INTERCONNECTION OR AT MAIN SERVICE U) J co _ Anne •`• •J DISCONNECT THE LABEL SHALL HAVE 3/8'TALL Q Q (L DUALPOWER.SOURCE"SECOND SOURCE IS: O' ' LETTERS AND BE REFLECTIVE WITH WHITE TEXT ON A Lu d Lu PHOTOVOLTAIC SYSTEM.; " ' RED BACKGROUND N NEC 705.12(D)(3) NEC 690.13(B) 0 SAFETY LABELS DOC ID:100054-125660-1 DATE:10/18/18 CREATOR:S.S. REVIEWER: REVISIONS PV-4 ROOF PROPERTIES f-100054 ROOF MATERIAL COMPOSITION SHINGLE(1 LAYER) SLOPE 8112(33.7°) MEAN ROOF HEIGHT 26FT DECK SHEATHING 7/16"OR THICKER OSB OR PLYWOOD RIDGE CONSTRUCTION TRUSSES(2X4 TOP-CHORD),241N OC ; ' l ` ' MODULE MECHANICAL PROPERTIES W MODEL SOLAR WORLD SW 295 MONO N DIMENSIONS(AREA) 165.91N X 39AIN X 1.31N(18.0 SO FT) W Lo �- WEIGHT 39.7LB M 4 i i f LLI of z W M MOUNTING SYSTEM PROPERTIES I p Q LL- 112.0IN(ZONE 1) cli MAX.ALLOW.RAIL SPAN 106.01N(ZONE 2) I I i ! ! I F I LLI N J 87.01N(ZONE 3) MAX.MOUNT SPACING 48.0114(ZONES 1,2,AND 3) f I ( I I I I I ! Q p = 44.BIN(ZONE 1)) ! J ICI MAX.ALLOW. 42AIN(ZONE 2) m CANTILEVER 34.81N(ZONE 3) Q ¢ M a GROUNDING AND INTEGRAL GROUNDING CERTIFIED W W BONDING -TO UL 2703 REQUIREMENTS 1 ATTACHMENT PLAN OBLIQUE PROJECTION N PV-5 SCALE:1/8°=V , NOTES RAFTER LOCATIONS ARE APPROXIMATE.ACTUAL 1 LOCATIONS MAY DIFFER AND CONTRACTOR MAY NEED 0 TO ADJUST MOUNT LOCATIONS.IN NO CASE SHALL THE MOUNT SPACING EXCEED'MAX.MOUNT SPACING" ATTACHMENT PLAN DOC ID:100054-125660-1 DATE:10/18118 CREATOR:S.S. REVIEWER: REVISIONS PV-5 P-100054 IRONRIDGE PV MODULE XR10 RAIL QUICKMOUNT QMLM COMP.SHINGLE ROOFING MATERIAL ""'=-��__.......;.-"- FLASHING INSTALLED BETWEEN UPPER AND >- C14 '.-.':. W < --'� - LOWER COURSE OF U M RAIL CLAMPING ZONE " = <a ,- Z W ch "i' SHINGLES w W Q J - %--`-- FASTENER EMBEDDED = u - INTO ROOF FRAMING a_ w I— '' C4 J ATTACHMENT DETAILS(TRANSVERSE VIEW) J N L .'". •r'�%•m�„-'"; `•.PV-6� SCALE:NTS 0 c:,:, �- :r U) '= MOUNTING NOTES p Q cy d .% .... FLASHING SHALL BE APPLIED IN ACCORDANCE WITH 1 W W MANUFACTURERS'PRINTED_INSTRUCTIONS._____ N IF THERE IS ANY CONFLICT BETWEEN WHAT IS DEPICTED p HERE AND INSTRUCTIONS PROVIDED BY THE 2 MANUFACTURER,MANUFACTURERS'INSTRUCTIONS SHALL �SUPERCEDE. ' A ',RACKING ELEVATION"(TRANSVERSE VIEW) PV MODULE l'•,PV-6,`SCALE_NTS " IRONRIDGE XR100 RAIL / — QUICKMOUNT �..__..._........_ QMLM COMP.SHINGLE ATTACHMENT �� — -- ---- -- r ROOFING MATERIAL DETAILS DOC ID:100054-125660.1 DATE:10118/18 �— ROOF FRAMING SPACING ATTACHMENT SPAN -- - FASTENER EMBEDDED .-- INTO ROOF FRAMING REVIEWER: CREATOR:S.S. ---- B'`,RACKING ELEVATION(LONGITUDINAL VIEW) / o �,ATTACHMENT DETAIL(LONGITUDINAL VIEW) REVISIONS `•�PV;6�'SCALE: NTS l';PV;6�'SCALE: NTS Pv-6 FIRE SAFETY REQUIREMENTS P-100054 N EXTERIOR-MOUNTED DC CONDUITS,WIRING SYSTEMS, AND RACEWAYS FOR PHOTOVOLTAIC CIRCUITS SHALL BE LOCATED AS CLOSE AS POSSIBLE TO THE RIDGE, HIP,OR VALLEY,AND FROM THE HIP OR VALLEY AS DIRECTLY AS POSSIBLE TO AN OUTSIDE WALL TO REDUCE TRIP HAZARDS AND MAXIMIZE VENTILATION OPPORTUNITIES(NFPA 111.12.2.2.4.1) ROOF ACCESS POINTS SHALL BE DEFINED AS AREAS WHERE FIRE DEPARTMENT LADDERS ARE NOT PLACED OVER OPENINGS(WINDOWS OR DOORS),ARE LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION,AND W 1 ARE IN LOCATIONS WHERE THEY WILL NOT CONFLICT (— WITH OVERHEAD OBSTRUCTIONS(TREE LIMBS,WIRES, (n N OR SIGNS).(NFPA 1 11.12.2.2.1.3) >- �. PHOTOVOLTAIC MODULES SHALL BE LOCATED NO U co."„.,I Icy;I I•�i ,, I ',,,�.,I �� CLOSER THAN 1-1/2 FEET TO A HIP OR VALLEY IF Of Z W MODULES ARE TO BE PLACED ON BOTH SIDES OF THE Lu HIP OR VALLEY.WHERE MODULES ARE LOCATED ON W Q J ' ONLY ONE SIDE OF A HIP OR VALLEY OF EQUAL LENGTH, LL THE PHOTOVOLTAIC MODULES SHALL BE ALLOWED TO O 7U7BE PLACED DIRECTLY _ VALLEY.(NFPA 111.10.2.22.1.9)T TO THE HIP OR PHOTOVOLTAIC MODULES SHALL BE LOCATED NO LESS Q p = i; � 4 THAN 3 FT BELOW THE RIDGE.NFPA 111.10.2.2.2.2) J N (f) Q M PV MODULES INSTALLED ON ROOF WITH IRONRIDGE 0 Q a. ROOF MOUNTING SYSTEM.THE MOUNTING SYSTEM IS W d W O UL 1703 CLASS A FIRE RATED ON A 8/12 SLOPED ROOF ''�'; - �'`•'" "1••1• +.;<-�`" WHEN INSTALLED WITH TYPE 1 OR 2 MODULES.THE N SOLAR WORLD SW 295 MONO IS TYPE 1. � O2 ROOF ACCESS POINT,PER NFPA 111.12.2.2.1.3 EE 1 FIRE SAFETY PLAN O 3.0 FT.WIDE FIRE ACCESS PATHWAY,PER NFPA 1 U PV-7 SCALE:1"=20' 3 11.10.2.2.2.1.3 AND NFPA 111.10.2.2.2.1.2 O ROOF ACCESS POINT,PER NFPA 111.12.2.2.1.3 5 CABLES,WHEN RUN BETWEEN ARRAYS,SHALL BE ENCLOSED IN CONDUIT. FIRE SAFETY PLAN DOG ID:100054-125660-1 DATE:10/18/18 CREATOR:S.S. REVIEWER: REVISIONS PV-7 ,SUnm6d l;i 'Pluis. .' . Sunmodule;/Plus . 511 285e300= ENO SW 285-300 MONO WEALVALUE z�__'__..-..,.sn,.�;. v.„,,.,,_ .,,.._,_...__._,<......-,._.,...-,,.,„,..„,_„ ,,.„.._____-.,,.....,..............................„..,._....__,..____._,«„,......,.._,°___.,,..,..,._..._.._..._..... PERFORMANCE UNDER STANDARD TEST CONDITIONS(STC)' SW 285 SW 290 SW 395 SW 300 �: .•� ` Maximum power P... 285 Wp _790 Wp 295 YVp 300 Wp fUV Power controlled: -^^"";',�:c opend—it voltage V, 397V 399V 400„ 401V Tflvlu,.:rlaiM' Lowest measuring:Dlerance in industry I 1 Maximum powerpaint voltage v,.,, 37.3 V 31 cv 31.5 V 316 V Short circuit current I,. 9.844 997A 1010A 1023A Maximum power point current I.., 9.20A 933A 945A 9.57A EVcry component is tested to meet I Module off cccy n 17,00°6 1730:s 17',; _ 1789% 3 times IEC requirementsI '$is 1000W/m+,25%.ants J g PERFORMANCE AT 800 W/M',NOCT,AM 1.5 5"285 SW 290 SW 29S SW 300 �"'" 2�; i i Maximum power P.,,, _ 2131 Wp 2)7.1 Wp 2205VIP 224)Wp - i t (3e51"ned t5,}V11t+S',no ncaVV # Open circuit voltage V„ 364V 366V 367V 369V acrsmulatlOFik Df snow one Ice 6 1 - :"o9V 311V Maximum Oowerpomt voltage V,,, _ 287V 288V J t Shortd—itcurrent 1„ 7.96A 8.06A 9 17 A 8.27A Maximumpowerpointcurren I_,, --- — 743A ---7.54A --- -- -- I E t 76nA 775A { 5unmodule Plus: ' a N.ir,m redu:linn in elL[eary had!r partiai!na1<n',d,!la,s,�25-C aL tiiG•Vl(m,ICoX ofthe STf.efli:'un[Y(1UPt W:n i:s a[n:evet Positive tolerance performance ; _—r ! I ..... COMPONENT MATERIALS . i laao w/m+ __ .._....... . ..... a per mo u e 60 rant Lmrv-.ron tempered gl°ss - { R0U WAn' ... _ ....... wt. AY,C(CN 12150) ;:.Door stalhne._.._.._.._._.__..............___._._............................._ ...... C y Frame lenr enaducd alumi,,urn i ar 2Swear lineal performance warranty ? 33 ... ............. aoow/na ............._............ cII type Shusbar and 10-yea,orodact warranty 3 .... 6.171n x 6.17in FAO tvim+ Cell dimenciom Weight 39.7lbs(18 0 kg) I :3 `, .............._. .._. (15O 7S zi5L75 rnml zoo tv/m' THERMAL CHARACTERISTICS ADDITIONALDATA too tilts _ x - {- _ - - Nocr 46'c Dowersarting -owp/tswp -- Glass with anti-rerledive coating "-'----.,._„, ...rr.. ".'_" V. TCI� 0044i/Y /-Box IP65 J TCV„ -0.30%/'C PV wire per U14703 3!5(9h11 Connector with H4/Urx--ctor: 420 '—� oc> -- Modu/efiregerfurmance (UL 1703)lypel World-class quality g�@g 0066s)_ i 4- Operating temp -40 to+85'C Fully-automated production lines and seamless monitoring of the process and DYe ...,,.. 'c88'`'" (.sees 0026(6.6) material ensure the quality that the company sets as its benchmark for its sites •:�,JY,°.n,,.. `'•°� �.., . ) PARAMETERS FOR OPTIMAL SYSTEM INTEGRATION 1 ....".u'_ UL t?03> ll'035(9) - I worldwide. �} _ � Masai mumrystemvoltageSCll/NfC toco•d Maximum revere current 25 A SolarWorld Plus-Sorting — -- Plus-Sortin, uarantees hi,hest s stem efficient.SolarWorld onl delivers modules I--r Num6er ofLypou diodes 3 P g P Y Y Y : i i na,aaar s that have greater than or equal to the nameplate rated power. I„';;-�' ' ' 8 I e Design/cads' Tworailsystem 113 psf downward,64 psf upward 4\ L Design leads* Three railrystem 178 psi downward,64 psf upward 25-year Linear performance guarantee and extension of product warramyto 10 years `-r'•^ S0IarW0f1d gUa rantees a maximum performance digression of 0.7%p.a.in the course '.,�„ l Designfaads• Edgemaunting 178psfdownward,4l list upward of25 yea rs,asignificant add edval tie corn pa red to the two-phasewarrantiescomMon n1e,s°,.fe,mthr t,cr,tnrmenet,a•assocUtrawnhth—mad[a,,, in the industry,along with our industry-first 70-year product warranty.' .Compatible with both'Tcp-Down' '5nlm[rik mnnufor.tu1,d in US A oI Crnuany U S A. and"Bottom'mounting methods • 'in acrordanrewith theapphrable SalaiWorld Limited Wa-,,tyat purchase, n31 I •3Grounding locations wwv+.solarworld corn/warranty 118750) -e Iocatlons along the Icogth of the °I module in the extended flenge i39.4(tODI)�I L !.30133? solarworld.com I Mun,t,p—de4 creimpenai Si unit;provided inp;entheses �" °'� Sa!swvrle:0,e>eive>i�e nght:c make.peufiutl°n chanEes++lIDaut notice SW.01-7SIOUS 161006 SC)IC-)re 0 a : So'arEd 9e POWer M°dule Add-On For ®p$�mpt�r ����/� P3201 P370/ North America So►or�d ule q 40p ge pO r „._ r � firth 7pi ter - ,.Jw, 5 r -o � n � 0 r P N Q(J� Ica 0 tfor F F370 UJ�r h'A[rumr_.i' for $._t _ $U5 Puta..... ., t 6ocell a d/os ! FoohlsherQ aver PP40 J__ CtbW _ F and tJ u s .: •Ahutut<Vf,t,,.: r m 7TA-req ifor7T Uv P .._. y - r� (tw,ai ica "rn lRVat 4 a 'rntt� 5 - Nh ast to .ctagr _ ndoles (tor tlet - .. .:...--.,:,.,., - ,6•: j.: _,.:..,.. MP m era: ..y1D' - 1 i`, n9tm j'SOS ) ., `.� _ Alp F... .... ... i ,W. �„.... , �. ...„ .:: .;_ - {. - �z•.:.';':,:' _ Mavis.,. GP den�u... .• 4A - 37U........ - doics7 (for ht8her ri ..,..,::!... .. "`•:.: .... : � -.. ..'`�.� a i -aR�','.4' �'�® ,`1Utn Shprt Cr .. nrrC'ff modtt • W t t a " ....... 44 ....iCS... _ .._.t........ .�,.:_ ...:�.-,:. r ••.'_y-. .., -,, r°`�!n f(fic;on.. ,u!Y c��" Sp -..ti.. Qv. n:gdcnar' ' ,...t-"i �• :�ey+C• .�s; ,our" ¢ Categorl,4... _ .. 2...�'ao 5 lti ..... -.. ' � ....,. iss. R 's - .d iv,JYcacs z, y 3 U7IIUPiNG OPE..... .. 116 :$Ytldtt2tid7tc `.z�' .f", htaxim4n Gu,;Put.urrzn?tA710NfPGN+£R OP77r1f12e ,.9a q'.. 94.5 .. ? 'f la... 'z`y .. '`_ �, OUtaU7 UURtNG Srt3 a •.i ,R C4NNEC7ED EO OPERA7ttt.. ..17. •..t...4cG " 0O, r�. Q r ,,�,y. - 4 at^ O +1 Ou:Pc+t:•Alid..hNDUY 1POWEA,OP71...�....„.. '-.-..NG SOLAREDGE tNV .. ..,.8.c" '..(... .. fJdUI�RR'',.,,tt tail y-t` y Eta Fh»lzrr d:P nvnr '_-h7tCEft �'... _ER7ER Y Zee ^�, .E 74tdDAAD C4MPLi"... ""' .. >,.dISC4NNECTED FROM S'^-.........._..-.....'S ' ..- 12afpj forNarftt tic ' 4 ANCE flU7REbGE.INbEAtERp i. " rt ' S ' �,r.•, ,irarj"7dho #:.` �,,, ,.« _,_. _.;,, ' ` ";�, °r�. °'..� : ., � .��StritLA7tOtP SPEC(F........_ � .. ..FCC Fart15..........,._, ., f) c Ito,7PRDf7,'�M`ft' Y$9$.2ett:. •-P41S5'- A Aa t+In m;. .�t.te,n toga e Cs12U9,t t 'C'•`,rECGlDO -,..... ^`..,vde -. -t ., thtnht ?5p Urpm #^:• "'.,'",""-`- ?...,..,,., mod iP3) i -^tforhf rnaRsk+,s 0A. tv °,ti. .GU,I U4,VrA:tQr u�d gut hti nttili�?,%vn rolre.tu::rN.i,{,.';e..�n 1,c ah ' 1�Sta .1.5k•SA9lt7 SaP i7a-.r1..E._.d..g.P...'T�','.$1"`•$7_5�'aU..e•/i,�e nfd- Th--.�...f 'tt.rCOr .O 21i61 �28,15.9721!'rxe 5u/ .f-...Vd. cpy 1 . .... _... j`'•:'-: �C'r��tJfh12r7¢j'... ' - ;.r a....!.ca;.''...,.....�di��:r>> Peri#FtatiYdesibnecf.eA : ,t}t?at.che'atpdral - ;;.,ysityet rdry ....1.... '•?i�utrretRs�,racPq.M:4. .1itts/.7:ii?• S•`nmar withSa! Cxy�,! •„vo.a�>•erro,:,rro�nzn,om,ru.�-i,.,rr�:, ra.+3s 1zr't.v.. enerBY•_ ar'rjBe inverter's '. ., .. . .... @ffjC78tYt,`' P{iSY$l' a Yfeiyg y{`J9.5g6. a .au"tE'°.dtf type "" :r _ _,_-... - '-. aStl,IAREDGEI tGN U5lNG- '.,,,,-...,,,.� ., 0;, .... "I+r. in # ,'.Ftexibte sofmadriJr+,},isnT ... ... .... •. ' '. "+t�Re:istQ et, V RTER t _ "°Fast .,sYsicn,dSign,kwin tchdosses,frb ". aXittp - ry}H7 ,` •.` taJa<er �Lfigery/Rfi A 2.Ci Pi:O,'PFp SJHU/WAHAS-_,_.'...................�'"_-'--,._ ... "�....C1 .. "Ncx' atio v+tth a Sin ur r space iraa'' .. ufactur#ng tale _ ., > - rat1CB .. r'•OAhmizers"rt„,h .. _...a,,,.. A5E~~7 ' - S/NGtE PA t$'enChc lion ' -b1N 647t :- - ...-'.:-., ,Ot7,, - to P3 , ,.} HRk .._ UE CnCC - - .. :,,.., _'monad - , ,: : - .',l .. ASE GmPr ant with ar`� Hance with n}adlate t.7HAE�P `' odute- c'auFiprotec£b;r ulptevolmonifare :. HASE levetvoka�esh t andrap4lshurr g'y rererieisrrn8loi":..• s`,J,1t nbrJ •,it.. s., t„, :� .......... la.... - . do wn Farm• low'r NFC sta(( dflr .. requt era en}a re f:ni 'runs ntensys" ... Self ppH.us eft} t.t g)tarsaf' ,.I,,zr a s..t,.t.k+rr>a,.,l rxFra:O:r.Ls=;•<.,.f MF•,7..1.fi,,,.. ;.,:. s ., installed.,' - •>`n,,.sv-,,n.ti�°ty spart Doru>„,e ...a,-r.;o.ra::•tvm�,.r,r.,:.,'. ........ veear vos+,n.ry•.s er,m&�Fusee•:.1.... ,.. .. ... '� $ r ­Uan� .. �ua 4 .. ..gP a . t1 VY f t}y .. , ne. ' ^ , , r.. mq�.: ' ..._... i t � - F. solar Single Phase Inverters for North America s 0 a rZa XoT SE110900H-US!S­140111-US ....................... ........... wui q,,76-6- O"'Us;' SolarEdge Single Phase Inverters OUTPUT, 7�_­,"I"­ _ ........... ...... .........- ............. for North America WM VA i im ........... Max.AC;�,v,O�tpt qi'C-q 5CC-0 '00 ilaou tA i -') Claw ?600 Lou SE300OH-0 SE380OH-US/SE500OH-US/SE600OH-US/ ........... ..... ... .. SE760011-US SE1 OOOOH-US 11 SEI 114 0011-US -all -A. if 7.,MV A .............. ...... 12 21 47�5 V ........... ............ .......... .... .... vrmty m'm 4: Ys ----------- Mpu 161 ... ...... ........... .. ........ 305 All, Vi♦ .CU'M.'t • 'K" . ......... Ad- ....... ""60 ...... ..... .... ......... la ............... w ................. ............ $Uipp"ow CO RS495,Eth-w,ngg'o .......... ............ .... .......... .....NEC2014al'd Rapid Sh,�RUOI x',Pl;paAAC,'_7�(a? 'K.)i 2 id b:5w;o,ej U11................ IF,1-0547,We lhde 14 Md ....... Cues n .......... r4 SPKp�K .......... ..................................... Jj4' j 2.0 1 AVG ........ ........................ AWC HD-Wave'techno Op,timized iii�iallationAvith logy',, 11,7 14,6 s l".8 145D.-M.174 7_3 1 0 SPWfiCL11V le st{ to wurk with powPr uptinl&em -4 .. ..... ... ...... .............. Recor ....... 2 Fikd�ofta 16vulter for lonwstrlrlk� • MA no Natural convection integrated rapld,,�htdown ftrr NEC2Oi4 and 2017 Per aqi&,690dl and 690,12 ....... .. ........ ................ P.m nip aroce"Ature Ran4e 'UL17-41 SA cer.ffied,for CPUC Rule 2't. g_rid complia ............... N(M, ....... ... Extreme y small ......... 'N 'XZ4 ," High reliabiljly wjthellt�lny i'l -,)rs 7 ailih-In mod6ln4levelmorihod'vii T. 111dMr installationl 4: ............... wave Simple Corifiguiatio;t and Conlrn'ssjohirlg with S(h6rtj)hVne Etpp and kl' ilift in WI-Fi(SE1000011-US,SE1140(IH,-,US) L �',W4 ,'2- IRONRIDGE Flush Mount System XR Raifis XR10 Rail XR100 Rail XR1000 Rail Bonded Splices �A A low-profile mounting rail The ultimate residential A heavyweight mounting All rails use internal splices for regions with light snow. solar mounting rail. rail for commercial projects. for seamless connections. 4� 6'spanning capability 8'spanning capability 12'spanning capability Self-drilling screws Moderate load capability Extreme load capability Heavy load capability Varying versions for rails Clear&black anod.finish Clear&black anod.finish Clear anodized finish Forms secure bonding Clamps Grounding UFOs Stopper Sleeves Grounding Lugs Microinverter Kits �0 A— Universal Fastening Objects Snap onto the UFO to turn Connect arrays to Mount Mls or POs to XR bond modules to rails. into a bonded end clamp. equipment ground. Rails. Fully assembled&tubed Bonds modules to rails Low profile Bonds devices to rails Single,universal size 6 different sizes Single tool installation Kit comes assembled Clear&black finish Clear&black anod.finish Mounts in any direction Listed to UL 2703 Built Aar So4lar's tr_t,,gheSt roots. lronRidge builds the strongest mounting system for pitched roofs in solar.Every component has been tested to the limit and proven in extreme environments. FlashFoot2 Slotted L-Feet Bonding Hardware Flush Standoffs Our rigorous approach has led to unique structural features,such as curved rails and reinforced flashings,and is also why our products are fully certified,code compliant and backed by a 20-year warranty. 7, " Strength Tested PE Certified A All components e -stamped engineering letters -in design for rapid rail Bond and attach XR Rails Raise Flush Mount System valuated for superior 54 �j Pre Flash and mount XR Rails Drop structural performance. available in most states. with superior waterproofing. attachment. to certified attachments. to various heights. Twist-on Cap eases install Secure rail connections T&Square Bolt options Works with vent flashing Wind-driven rain tested Slot for vertical adjusting Nut uses 7/16"socket 4"and 7"lengths Clear&black anod.finish Ships assembled Class A Fire Rating Design Assistant Mill&black finish Assembled&lubricated Certified to maintain the fire N resistance Online software makes it simple to Resources rating of the existing roof. - ', create,share,and price projects. Design Assistant NABCEP Certified Training UL 2703 Listed System to fully continuing education credits, q7U 20-Year Warranty Go from rough layout Earn free engineered system.For free' while learning more about our systems. Entire system and components meetTwice the protection offered by .......I., Go to E:1 Co to vde L.N., newest effective UL 2703 standard. competitors. FT', 11495 Zephyr Avenue I 4544 5 Zephyr Ave nue t�_ IRONRIDGE !Hayward CA 94544 IRONryI GE I'llayward,CA 1-)00.227-9523 1-800. 23 IronRidge.com IronRidge.com Attn:Corey Geiger,VP New Markets,IronRidge Inc. The span tables provided in this letter are certified based on the structural performance of IronRidge XR Rails only with no Date:December 20t',2017 consideration of the structural adequacy of the chosen roof attachments,PV modules,or the underlying roof supporting members. It is the responsibility of the installer or system designer to verify the structural capacity and adequacy of the Re:Structural Certification and Span Tables for IronRidge Flush Mount System aforementioned system components in regards to the applied or resultant loads of any chosen array configuration. This letter addresses the structural performance and code compliance of IronRidge's Flush Mount System. The Flush ��11te1retrrrrrr Mount System is a proprietary rooftop mounting system used to support photovoltaic(PV)modules installed in portrait or Sincerely, ,,��`t-;;P1Ci ;;L q�✓'err�J landscape orientation and set parallel to the underlying roof surface. PV modules are supported by extruded aluminum G[.r�<:•. XR Rails and secured to the rails with IronRidge mounting clamps. The XR Rails are side mounted to a selected roof R V !' • No u'iD9 •'.'�'=• attachment with 3l8"stainless steel bonding hardware and then attached directly to the roof structure or to a stanchion that is fastened to the underlying roof structure. Assembly details of a typical Flush Mount installation and its core -7� components are shown in Exhibit EX-0015. / ,,A1L GrpThe c st ndardstdge Flush Mount System is designed and certified t the stctural for the load conditions and configurations tabulated on the attached span tables: of the following reference !� s,�rONAL���. Gang Xuan,PE,LEED AP rrneurni` Senior Structural Engineer. ASCE/SEI 7-10 Minimum Design'Loads for Buildings and Other Structures(ASCE 7-10) 2015 International Building Code(IBC-2015) Florida Building Code V Edition(2017)Building 2015 Aluminum Design Manual(ADM-2015) The tables included in this letter provide the maximum allowable spans of XR Rails in the Flush Mount System for the respective loads and configurations listed,covering wind exposure categories B,C,&D,roof zones 1,2&3,and roof slopes from 01 to 45°. The span tables are applicable provided that the following conditions are met: 1. Span is the distance between two adjacent roof attachment points(measured at the center of the attachment fastener) 2. The underlying roof pitch,measured between roof surface and horizontal plane,is 451 or less. 3. The mean roof height,defined as the average of the roof eave height and the roof ridge height measured from grade,does not exceed 30 feet. i 4. Module length shall not exceed the listed maximum dimension provided for the respective span table and module width shall not exceed 40". 5. All Flush Mount components shall be installed in a professional workmanlike manner per IronRidge's Flush Mount installation manual and other applicable standards for general roof construction practice. i F t ©2017 IronRidge,Inc. FL Flush Mount System Certification Letter-1 C�2017 IronRidge,Inc. FL Flush Mount System Certification Letter-3 ff-1 T Mg �"L The Flush Mount System may be used to ground and/or mount a PV module complying with UL 1703 only when the It- -2-Q- specific module has been evaluated for grounding and/or mounting in compliance with the included instructions.Unless 1 Modules with 46mm frames and model identifier PV-MYYxxxZZ;where"W"is LE or JE;and"ZZ" otherwise noted,"xxx"refers to the module power rating and both black and silver frames are included in the certification. Mitsubishi is either HID,HD2,or FB. 'r" IM and XS series modules with 40,45,or 50mm frames. I Modules with 35,40,or 45mm frames and model identifier aaSM66yyPzz-xxx;where"aa"is CH Neo Solar Power -1-Modules-----,-w,i,t-h--3-5-m-m---fr-a-m--e,s-an,'d,-m-o,-d e--1--d-e-rit-i identifier-D,-6,-Y--x-x,'x-'Z'Z'-aa--;,w---h,-e,-r-e'-"Y-,-' b--e,-M-,or-P-;-Z ...... i17 a��- L-,ViYF F'can i be 33A,B4A,E3A,E4A,H3A,H4A;and"aa"can be blank,(TF),ME or ME(TF). AsIronergy Solar or A;"yy"is either 10 or 12;and"zz"is blank or(BL).Frameless modules with model identifier .......... .............................................................. ...............................................-.............. ............................................... CHSM661OP(DG)-xxx. Modules with 35 or 40mm frames and model identifier VSHNxxxYYzz;where"W"is SA or I Panasonic an III ------ ....... ---------.............. ............. "zz"is 01,02,03,04,06,06B,11,11B,15,15B,16,16B,17,or 18. Modules with 35 or 40mm frames and model identifier AC-xxxY/aa-ZZ;where"Y"is M or P;"aa!'is 125 Axitec Modules with 35,40,or 45mm frames and model identifier PSxxxY-ZZIA;where"Y"is M or P; "ZZ" or 156;and"ZZ"is 54S,60S or 72S. Phono Solar .......................... ................. ........... ... ......................... ....................................... --- is 20 or 24;and"A"is F,T or U. L--------------- .......... -------............. ------- .............. I Modules with 35 and 40mm frames and model identifier CSbY-xxxZ;where"b"can be 1,3 or 6,"Y"can be K,P,U V,or X;and"Z"can be M,P,AG,MS,PX,M-SD,P-AG,P-FG or P-SD,MS-AG,MS-FG,or I Prism Solar Frameless modules with model identifier BiYY-xxxBSTC;where"W"is 48 or 60. Canadian Solar MS-SD.Frameless modules with model identifier CSbY-xxx-FG;where V'can be 3 or 6;"Y"is K,X,or i Modules with 30,38 and 45mm frames and model identifier RECxxxYYZZ;where"W"is M,PE REC Solar P;and"Z"can be M-FG or P-FG. TP,or TP2S;and"ZZ"is blank,BLK,SLV,or 72. -------........................ -------- .................................. Modules with 35,40,or 50mm frames and model identifier ET-Y6ZZxxxAA;where"Y"is P,L,or M;"ZZ" Modules with 35,40 or 50mm frames and model identifier JCxxxY-ZZ;where Y'is F,M or S,and I ET Solar 1 Renesola is 60 or 72;and"AN'is WB,WW,BB,WBG,WWG,WBAC,WBCO,WWCO,WWBCO or BBAC. "ZZ"is Ab,Alo-b,Abh,Abh-b Abv,Abv-b,Bb,Bb-b,Bbh,Bbh-b,Bbv,Bbv-b,Db,or Db-b. Modules with 35,40,or 50mm frames and model identifier FXS-xxxYY-ZZ;where"xxx"is the module I Renogy Modules with 40... or 50mm frames and model identifier RNG-xxxY;where"Y"is D or P. ............................... .........­­.............. Flex power rating;"YY"is 613 or BC;and 7Z"is MAA1 B,M AA 1 W,M AB I W,SAA1 B,SAA 1 W,SAC 1 B, Modules with 40mm frames and model identifier SNxxxY-ZZ;where"Y"is M or P;and"ZZ"is 10,or SAClW,SADlW,SBAlb,SBAlW, SBC1 B,or SBC1 W. S-Energy 15. Modules with 35 and 40mm frames and and model identifier GCL-a6/YY xxx;where"a"can be M or P; GCL Modules with 40mm frames and model idenfifier SEG-6YY-xxx where YY can be MA,MB,�A,' and"YY'can be 60,72,or 72H. Seraphim Energy Group j PB,and"ZZ"can be BB,WB,or WW. GigaWatt Solar Modules with 40mm frames and model identifier GWxxxYY;where"YY"is either PB or MB. 1:Modules with 40 and 50mm frames and model identifier SRP-xxx-6YY;where"W"can be MA,MB. ................ ................_..........I._................._. ......................- ......................................I........................ ........................................ [Seraphim USA t PA,PB,OA-XX-XX,and QB-XX-XX.. Modules with 40,45,or 50mm frames and model identifier HSLaaP6-YY-1-xxxZ;where"aa"is either 60 . ... .... . ....................... HanwhaSolar .................................................................. 0,and 42mm frames and model identifier aaYY-ZZ-xxx;where"aa" be Q.or d-1 or 72;"W"is PA or PB;and Z'is blank or B. I Sharp Modules with 35 or 40mm frames and model identifier NUYYxxx;where"YY"is SA or SC. :_ Modules with 38mm frames and model identifier SYY-Z-xxx;where SA LA:SG or LG;and B.:"W"can be PLUS,PRO,PEAK,LINE PRO,LINE PLUS,or PEAK DUO;and"ZZ"can be G3,03.1 Fflfab, Modules with 32,35,4 in "Z"is M,P,or X. G4,G4.1,L-G2,L-G2.3,L-G3,L-G3.1,L-G3y,L-G4,L-G4.2,L-G4y,LG4.21TAA,BFR-G3,BLK-G3, rHa'n'wh'a 0 CELLS Modules with 40mm frames and model identifier PowerXT xxxY-ZZ;where Y'can be R or C;and BFR-G3.1,BLK-G3.1,BFR-G4,BFR-G4.1,BFR G4.3,BLK-G4.1,G41SC,G4.1/SC,G4.11TAA,G4.1/ Solaria -ZZ"is BX.BY,PX,PZ,WX or WZ. MAX,BFR G4.1rFAA,BFR G4.1/MAX,BLK G4.1rrAA,BLK G4.1/SC,EC-G4.4,G5,BLK-G5,L-G5.2,or L-G5.2/H. larTech Modules with 42mm frames and model identifier STU-xxxYY;where"W"can be PERC or HJT. .......... -------........ -S. ........... Modules with 40mm frames and model identifier YYZZxxx;where"YY"is 36,60,72,or 96;and"ZZ"is Sunmodule Plus,Protect,XL,Bisun,Bisun XL,may be followed by mono,poly or duo and/or black Heliene M,P,or MBLK. SolarWorld or bk;modules with 31,33 or 46mm frames and model identifier SW-xxx. ................--........................---.................. .................... Hyundai Modules with 35,40 and 50mm frames and model identifier HiS-Yxxxzz:where"Y"can be M or S;and Thin film modules with 35mm frames and model identifier STO-xxx or STO-xxxA.Thin film Stion I "ZZ"can be MI,MF,MG,SG,RI,RG(BF),RG(BK),TI,or TG. 1 frameless modules with model identifier STL-xxx or STL-xxxA. Modules with 40 or 50mm frames and model identifier IT-xxx-YY;where"W"is blank,HE,or SE,or Modules with 35,40,or 50mm frames and model identifier SE-YxxxzABCDE;where Y'is B,F,H, Itek SE72. SunEdison P,R,or Z;"Z"is 0 or 4;"A"is B,C,D,E,H,1,J,K.L,M,or N:"B"is 8 or W;"C"is A or C;"D"is 3, Modules with 35,40 and 45mm frames and model identifier JAyyzz-bb-xxx/aa;where"yy"can be M,P. I 7,8,or 9;and"E"is 0,1 or 2. JA Solar i M6 or P6;"zz"can be blank,(K),(L),(R),(V),(BK),(FA),(TG),(FA)(R),(L)(SK),(L)(TG),(R)(BK),(R) Modules with 35,38,40,46,or 50mm frames and model identifiers OPTxxx-AA-B YYY-Z (TG),(V)(BK),(BK)(TG),or(L)(BK)(TG);"bb"can be 48,60,72,60SOI or 72501;and"aa"can be MP, Suniva or MVXxxx-AA-B-YYY-Z;where"AA"is either 60 or 72;"B"is either 4 or 5;'YYY'is either SI,SC,PR,RE,3BB,4BB,4BB/RE,51313. 1100,101,700,1B0,.or 1B1;and`Z"is blank or B. .................... Modules with 40mm frames and model identifier JKMYxxxZZ-aa;where Y'is blank or S;"ZZ"is P. Modules with model identifier Ab-xxx-YY and standard(G3)or InvisiMount(G5)45mm frame; Jinko PP.M;and"aa"is 60,60B,60-J4,60B-J4,60(Plus),60-V,72,or 72-V.Frameless modules with model Sunpower t where"A"is either E,P or X;"b"can be 17,18,19.20,21,or 22:and"YY"can be blank,NE,BLK, -DV. i identifier JKMxxxPP COM,C-AC,D-AC,BLK-C-AC,or BLK-D AC. ....... Modules with 46mm frames and model identifier KYxxxZZ-AA;where"Y"is D or U;"ZZ"is blank,GX,or 1 Sunpreme Frameless modules with model identifier GXB-xxxYY;where"W"Is blank or SL. Kyocera SX;and"Wis LPU,LFU,UPU,LIPS,LPB,LFB,LFBS,LF82,LP82,3AC,313C,3FC,4AC,4BC,4FC, Suntech Vd,Vem,Wdb,Wde,and Wd series modules with 35,40,or 50mm frames. t................................................... ......... --------- :4UC,SAC,5BC,5FC,5UC,6BC,6FC,BBC,6MCA,or 6MPA. ................... .......... Modules with 35,40 or 46mm frames and model identifier TSM-xxxYYZZ;where"YY"is PA05, LG Modules with 35,40,and 46mm frames and model identifier LGxxxYaZ-bb;where"Y"is A,E,N.0,S; PC05,PD05,PA14,PC1 4,PD1 4,PE14,or DD05;and"ZZ"is blank,A,A.05,A.08,A.1 0.A.1 8_05, "a"is I or 2;7"is C,K,T,or W;and"bb"is A3,A5,B3,G3,G4,or K4. Trina 1.08,.10..l 8,.OBD,.18D,0.82,A.082(11)..002,.00S,05S,OBS,A(II),A.08(l]),A.05(11),A.10(I1),or 1 A.18(11).Frameless modules with model identifier TSM-xxxYY;and WY"is either PEGS,PEG5.07, Longi Modules with 40mm frames and model identifier LR6-YY-xxxM;where"W"can be 60,72,or 72HV. 1 PEG1 4,DEG5(II),DEG5.07(11),or DEG-14(11). I Modules with 35 or 40mm frames and model identifier Wsy-xxxz6;where'y"is either P or-P, Mission Solar i Modules with 40mm frames and model identifier MSExxxZZaa;where"ZZ"can be MM,SE.SO or SO; Winaico and z is either M or R and"aa"can be 1 J,4J,4S,5K,ST,6J,6S,or 6W. -----------T-------- --------................. ............. ............. �da,YGE,.and YGE-U series modules with 35,40,or 50 mm frames. LK1201:1.--........................ ....... ............. L-Mount Installation Instructions L-M®u nt Q M LM / Q M LN12 Installation Toots Required:tape measure,roofing bar,chalk line,stud finder,caulking gun,sealant compatible with roofing materials,drill with 7/32"bit,drill or impact gun with 1/2"socket. Elevated Water Seal Technotogyo ._........................_. .........._..................._._..__...._......................._..__......_.._... .. ......... ..................... ......_...........................� REM ,r I THIS EDGE TOWARDS ROOF RIDGE NO. N QTY. l 1 FLASHING,ROUNDED CORNERS,9"X I2"X.040 5052,MILL 1 7• �.i„ I 2 L-FOOT,2"X 3.30"FOR.438"O.D.FASTENER,6061-T6/6005A-T61.MILL I •e}' I ! 3 WASHER.SEALING,5/16"ID X 3/4"OD,EPDM BONDED SS I '-'>"•' 1 7 4 LAG SCREW,HEX HEAD.5/16"x 4".18-8 SS i L-FOOT 2"X 3.30,2 X.75'SLOT FOR.438"O.D.FASTENER,6061- T66005A-T6I MILL ,� .;•�^�";.' '�=`''' j 12I00 2X.75"SLOT VERSION -"------------- Locate choose and mark centers of rafters to be Carefully lift composition roof shingle ngle with roofing Insert flashing between 1st and 2nd tours Slide I e. 'OPTIONAL mounted"Select the courses ofshingles where bar,just above placement of mount.Remove u so to edge of flashing Is at least 314"higher ` ......._................. 1 g 1 P P P g g g - 3 mounts well placed. - : .i•^,�• I he la nails as required and backfill holes with aproved than the butt ed a of the 3rd course and lower 9 sealant.See"Proper Flashing Placement"on next flashing edge is above the butt-edge of Ist course. i ! t t l page. Mark center for drilling. ..............._....__.... 2 ^._..4..5 ski^ i i 0 O ' 1 .n .......r Tl P y 1 •wa," at,t•i,, : ";;•,day„. �, r = 3•-'��+ "C• +c..a j 1 AVAILABLE IN MILL,AND BLACK FINISHES - t........t....j z_ J y j......_._f... Quick Mount PV ...TREE:.......................... .__.—.—...................._.._.......... i .0 --i_ I =,4; QMLM2 QMLM:L-MOUNT,5/16"LAG,9" Using drill with 7/32"bit,drift pilot hole into roof Clean off any sawdust,and fill hole with sealant Place L-foot onto elevated flute and rotate L-foot to l'�' I X 12"FLASHING and rafter,taking care to drill square to the roof. compatible with roofing materials. desired orientation. l ...�.._........... ....... .1.... Do not use mount as a drill guide.Drill a 2"deep I QIVILM U4lEIE OnBPwOEEPEQaED. SIZE DRAWN BY: RAD REV i hole into rafter. 'IDwEsom AeEwu.au .......... ................ I 1 roL'.vn,4u A DAfE: 4/M/M11 5 i r+aim'ea�,..rYOi,crwa"i°u°"�"wne COPYeOe,,.r,w.:e,.tsa,raw.rno•w :IC w.er»cuewwe,n cau,,,.°u•mwu•:n "" o0"OrfC,L[OewwxG ��E DC u+n ' vnm�rpwwoncrcue,xcu"rvnrvD"m•.o alO2DUGt01{OUIC°MOUM PV , ", D]D] SMEErI C M L•M, SCnLEIe V2 GM:1 F I 5 4 3 2 1 :..------- -------- t.A Qa fy a®�pq� ^ Prepare lag bolt with sealing washer. Using a 1/2 You are:now ready for the rack of your choice. u'6e j�v` f i Inch socket on an impact gun,drive prepared lag Follow all the directions of the rack manufacturer RESPECT THE ROOF bolt through L-foot until L-foot can no longer easily as well as the module manufacturer.NOTE:Make rotate.DO NOT over-torque. sure top of L-Foot makes solid contact with racking. BI 7.2.3-44 Jun-2017 Rev BI 7.2.3-44 Jun-2017 Rev DIRECTORY OF PAGES SCOPE OF WORK P-100054 PV-1 PROJECT SUMMARY r pJ 3 THIS PROJECT INVOLVES THE INSTALLATION OF SOLAR Jr PANELS.THE SOLAR PANELS WILL BE RACKED USING A PV-2 SITE PLAN PREENGINEERED RACKING SYSTEM.THE RACKED MODULES PV-3 SINGLE-LINE DIAGRAM WILL BE ELECTRICALLY CONNECTED WITH DC TO AC POWER INVERTERS AND INTERCONNECTED TO THE LOCAL UTILITY PV-4 SAFETY LABELS 12th Ave . : 121h Ave t 211t Are USING MEANS AND METHODS CONSISTENT WITH THE RULES ENFORCED NF RCEDO Y THE LOCAL UTILITY AND PERMITTING PV-5 ATTACHMENT PLAN PV-6 ATTACHMENT DETAILS PV-7 FIRE SAFETY PLAN ° THIS DOCUMENT HAS BEEN PREPARED FOR THE PURPOSE OF W DESCRIBING THE DESIGN OF A PROPOSED PV SYSTEM WITH MODULE DATASHEET - ENOUGH DETAIL TO DEMONSTRATE COMPLIANCE WITH ~ APPLICABLE CODES AND REGULATIONS.THE DOCUMENT � OPTIMIZER DATASHEET SHALL NOT BE RELIED UPON AS A SUBSTITUTE FOR W �- X - FOLLOWING MANUFACTURER INSTALLATION INSTRUCTIONS. CA Lr) o INVERTER DATASHEET - THE SYSTEM SHALL COMPLY WITH ALL MANUFACTURERS U co T LISTING AND INSTALLATION INSTRUCTIONS,AS WELL AS ALL Z W M LLi MOUNTING SYSTEM DATASHEET `r APPLICABLE CODES.NOTHING IN THIS DOCUMENT SHALL BE W W a INTERPRETED IN A WAY THAT OVERRIDES THEM. a MOUNTING SYSTEM ENGINEERING LETTER �� ,. p Q LJL Q CONTRACTOR IS RESPONSIBLE FOR VERIFICATION OF ALL W = UL 2703 GROUND AND BONDING CERTIFICATION ^' CONDITIONS,DIMENSIONS,AND DETAILS IN THIS DOCUMENT. ANCHOR DATASHEET < - rL N J PROJECT DETAILS :r:,r•nsm G1er.,c«�a SYSTEM DETAILS Q CD2 NEW GRID4NTERACTIVE 0 N Lo PROPERTY OWNER PAIAZZI 1 Cn PLOT DESCRIPTION PHOTOVOLTAIC SYSTEM WITH NO Q � PV-1 SCALE:NTS BATTERY STORAGE J r-.) _ PROPERTY ADDRESS 3905012TH AVE.ZEPHYRHILLS,FL c) Q 11 33542 US DC RAT ING OF SYSTEM 13,865W W W W APN $t�iE AC RATING OF SYSTEM 10,000W N ZONING RESIDENTIAL -G N= _ - - AC OUTPUT CURRENT 42.OA jw.� Ri�hl.:rE1 INVERTER(S) 1 X SOLAR EDGE SE10000H-US USE AND OCCUPANCY ONE.OR TWO-FAMILY DWELLING ., CLASSIFICATION GROUP(GROUP R3) �t : - - MODULE SOLAR WORLD SW 295 MONO AHJ ((1)STRING OF 19 UTILITY COMPANY PROGRESS ENERGY FLORIDA INC _ ` ARRAY WIRING (1)STRING OF 20 L] i ELECTRICAL CODE 2014 NEC(NFPA 70) FIRE CODE 2015 NFPA 1 t INTERCONNECTION DETAILS POINT OF CONNECTION NEW SUPPLY SIDE AC CONNECTION CONTRACTOR INFORMATION Zliltyr!tlls;Zepnv hlls jppn; PER NEC 705.12(A) COMPANY BAY AREA PROJECT SOLUTIONS _ r".` 4�ztil[�City UTILITY SERVICE 120240V10 . @Kydiae ;Z *,�. •- •Fre:stzt�e. LICENSE NUMBER SOLAR DISCONNECT EATON DG222NRB,2-POLE,60A, 240VAC ADDRESS 2512 BAY FIELD CT,HOLIDAY,FL 34691PHONE NUMBER (727)543.8361 '' " . SITE DETAILS PROJECT ASHRAE CONTRACTOR A`.aptlnmE`E?':Bhicxf'- ASHRAE2/HIGHELOW C 93FF) SUMMARY SIGNATURE CLIMATE DATA SOURCE ST.PETERSBURG CLEAR(KSPG) 2 LOCALE DOc10:1ooasa-1z5sso-1 PV-1 SCALE:NTS WIND SPEED 170 MPH(ASCE7-10) DATE:10118118 RISK CATEGORY II CREATOR:S.S. REVIEWER: WIND EXPOSURE CATEGORY REVISIONS GROUND SNOW LOAD PV-1 INSTR#201 81 80741 OR BK 9807 PG 3615 Page 1 of 1 10/24/2018 03:18 PM Rcpt:2000737 Rec: 10.00 DS: 0.00 IT:0.00 PauCa S. O:'Weit;Ph.D., Pasco County CCerk&ComptroCCer PREPARED BY:STEPHANIE COFFEY 2512 BAY FIELD CT,HOLIDAY FL 34691 NO'hICE OF COMMENCENIF,NT 1'crnut No 1')opctte ldcnniti tot+n\o 12-26-21-0260-00400-0330 1111 1:N111 R`ION) l)hcreb% gte e�nonce that tmproe anent,,will he made In Certan3 rC,il propem and m acc++rdancc will 1,wr•n -I I;++i,tile Honda tit.tnnC,.the li+lloautg information t�pmetdCd in the NOTICE OF COMMENCEMENT 1 lk.Cnpnon of prolxj(1ePfll� ,ipt�rtr4 COLONY HEIGHTS UNREC LOT 33 BLOCK 4 a 1 titrect address JUU��UU �rll AAVV ( cnal description INSTALLATION� s r)now Information at Name and address CATHERINE PALAZZI, 39050 12TH AVE, ZEPHYRHILLS, FL 33542 h t N:une and address of fee svnplc titleholder t tf other than uwncn c t lnterc;t to pnelxrt) 100% 1 Contractor Indaddre`rn DON WARNER, 12241 GARDEN LAKE CIRCLE, ODESSA. FL 33556 a t Name and addre.'-. h> '1 clephonc No. b1 - bb2Fa\No t()pt ) i Sunte Information NIA a) Name and address h) ;Amount of Bond c i Telephone No Fax No i0pt ? t, Lender N/A a) Name and address: 7 Identity of person within the State of Florida designated b% owner upon whom notices or other documents maev b e sen-CLI, a) Name and address: N/A —_ h) Telephone No.: Fax No.(Opt ) R. . 111 addition to himself, w oner designates the following person to receive a copy of the Lieno{ Sections Notice as provided in Section 13(l)(h),Florida Statutes: NIA a) Naine and address: b) 'telephone No_ Fax No.(Opt.) 9 Expiration date of Notice of Commencement(the expiration date is one ycar from the date of recording unless it different date 1; Specified) WARNING TO OWNER:ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713,PART 1,SECTION 713.13, FLORIDA STATUTES AND CAN RESULT IN YOUR PAYING TWICE FOR IPROVEM TS TO YOUR PROPERTY.A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POST; D ON THE JO E BEFORE THE FIRST INSPECTION.1F YOU INTEND TO OBTAIN FINANCING,C NSULT YOUR LE E OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOU NOTICE 7 COMMENCEME STATh OF H2ORIDA C'OI'\T1'OF PASCO J/' Sig Owns or O%vner's Authorized OfliecT DirectorPartnec\tanager CATHERINE PALAZZI Print Name -- The foregoing instrument was acknowledged before me Pis A? day of�L¢�fed' 20 ��,by as _ D (type of au city,e.g.r ice r trustce itnrncv in tact)for --- Gy�.ry._ �� _ (n a of party on behalf of whom inst cw ex ute Personally Known OR Produced ldenblicaiion Ic Notary Signature Type of Identification Produced _—. Name(print) r Verification pursuant to Section 92.525.Florida Statutes.Under penalties of pedun•,I declare that I have read the foregoing and that the facts stated in it are:true to the best of me knowledge and belief. F�R.e1S SGi nsd:Uri SitTawe of~aural Fmon SWngq AL- ... ADAM I'RANC" MY COMMISSION#GG 120610 ter ; EXPIRES:July 2.2021