HomeMy WebLinkAbout18-17978 i
CITY OF ZEPHYRHILLS
5335-8TH STREET
(813)780-0020 17978
BUILDING PERMIT
PERMIT INFORMATION LOCATION INFORMATION
Permit Number: 17978 Address: 5938 FOREST LN
Permit Type: ACCESSORY BLDG. ZEPHYRHILLS, FL.
Class of Work: SHED INSTALLATION Township: Range: Book:
Proposed Use: SINGLE FAMILY RESIDENTIAL Lot(s): Block: Section:
Square Feet: Subdivision: FOREST VILLAS
Est. Value: Parcel Number: 10-26-21-0110-00000-0030
Improv. Cost: 2,400.00 OWNER INFORMATION
Date Issued: 3/21/2018 Name: KNOX KATHY PAHL
Total Fees: 82.50 Address: 5938 FOREST LN
Amount Paid: 82.50 ZEPHYRHILLS, FL. 33542
Date Paid: 3/21/2018 Phone: (813)992-3174
Work Desc: INSTALLATION 10 X 10 SHED
CONTRACTORS APPLICATION FEES
HOMEOWNER BUILDING FEE 82.50
i
Ins ections Rodffied
FRAME
SHEATHING
FINAL
REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the
local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or
first reinspection,whichever is greater,for each such subsequent reinspection.
NOTICE: In addition to the requirements of this permit, there maybe additional restrictions applicable to this property that
may be found in the public records of this county, and there may be additional permits required from other governmental
entities such as water management, state agencies or federal agencies.
"Warning to owner: Your failure to record a notice of commencement may result in your paying twice for
improvements to your property. If you intend to obtain financing, consult with your lender or an attorney .
before recording your notice of commencement."
Complete Plans,Specifications Must Accompany Application.All work shall be performed in accordance with
City Codes and Ordinances. NO OCCUPANCY BEFORE C.O.
NO OCCUPANCY BEFORE C.O.
I
CO1qf RACTOR SIGNATURE PERMIT OFFI R
PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION
CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED
PROTECT CARD FROM WEATHER
I
i
813-780-0020 City of Zephyrhills Permit Application Fax 813-780-0021
Building Department °>
Date Received
• • Phone,Contactforftrmittin
Owner's Name (,LY�Q{i Owner Phone Number `l �'�J 7
Owner's Address r Owner Phone-Numb'or17
Fee Simple Titleholder Name" Owner Phone Number —
z '
Fee Simple Titleholder Address
JOB ADDRESS LOT#
SUBDIVISION �uyt? U l lI aS PARCEL ID# W�
(OBTAINED FROM.PROPERTYTAX NOTICE)
WORK PROPOSED: NEW CONSTR ADD/ALT %' SIGN` •'_' ;. = DEMOLISH
�. INSTALL ='. ,. REPAIR
PROPOSE®..USE = SFR = COMM
TYPE OF CONSTRUCTION =' BLOCK FRAME STEEL ._ ^
DESCRIPTION OF WORK-,.
BUILDING SIZE• I sQ FOOTAGE "• ..:HEIGHT -
BUILDING $ VA TION:`OF`TOTAL-CONSTRUCTION }
=ELECTRICAL $ AMP SERVICE = PROGRESS'ENERGY [� W.R.E.C.
=PLUMBING,.. $
-
=MECHANICAL $ VALUATION OF;MECHANICAL INSTALLATION.
=GAS = ROOFING ;_- . SPECIALTY,:,C] -,,OTHER,
FINISHED FLOOR ELEVATIONS FLOOD ZONE AR =YES. NO
BUILDER.. --- • .- -_ - -SIGNATURE
L�
REGISTERED / N FEE CURREN' Y
Address L'Icense#'
ELECTRICIIN: -COMPANY'
SIGNATURE REGISTERED Y/ N FEE CURREn '
Address License#
PLUMBER , COMPANY
SIGNATURE' . .
;. REGISTERED: ::._, ,- ""X VN, ,:- -.FEE:CURREN; Y,"/
Address ;License.#`
i
MECHANICAL: - Y
COAAPANY
SIGNATURE ..
REGISTERED.,: Y,/.N..:':. . FEE CURREh; Y/;N"
Address,;; _ License#.
OTHER .
SIGNATURE .. ..
;COMPANY` ry
'REGISTERED Y/ N FEE CURREN
Address License#
RESIDENTIAL,; -Attach?(2),Plot%Pla1rW(2)sets of`tiuil'ding Rlans (1)`sef of Energy Forms;R=0=V1/°'Pertrilt for new°construction,
Minimumyten°_(:1.0),working;days;aftersubmittal-date::Requir"ed onsitbj Constrt ctidh P-Ians,Stormwater'Planslw%Silt
'Fence installed,
Sanitary Facilities-,&;1,::dumpster,_;,Site,Work:P,,ermit;for;subdivisions/large pro1ecfs_'
COMMERCIAL Attach(3)•complete sets of Buildlog Plans plus a Life SafetyPage;�(1)set of Energy Forms.R-O-W Permit for neW cansttrruction..i
Minimum ten(10)working days'after submittal date. Required onsite,Construction Plans,Stormwater Plans.w/Silt Fenoe Installed,
Sanitary Facilities&"1 dumpster.Site Work Permit for all newaprojects:All commercial requirements.must meeYcompliance• 5
SIGN PERMIT Attach"(21"sets of-Eriginee[edPlans::,•
****PROPERTY SURVEY regulred for all NE 1N construction..
Directions:
Fill out application completely.
Owner&Contractor sign'back of application,notarized
If over$2500,a Notice of Commencement Is required. (A/C upgrades over$7500)
Agent(for the contractor)'or'PoWdr,of Attorhiy'(for the owner)"would be someone with notarized letter from owner authorizing same V,�y
OVER THE COUNTER.PERMITTING-. --. •(Front of Application-Only) {--
Reroofs if'shingles Sewars Service,Upgrades A/C Fences(Plot/Survey/Footage) f
Driveways-Not over Gunter.[Con•pubI1c_roadways..needi ROW` -- ='_'.;•"{
Sheds
Plan Review Comments
1) All property markers shall be fully exposed at time of inspection. (RED TAG IF NOT
MARKED)
2) All sheds shall be installed and anchored per manufactures specifications. (RED TAG IF
NOT ANCHORED PER PLAN)
3) All set-backs shall be met.
4) Shall be set in the rear or side yards.
5) Only 2 accessory buildings per parcel.
6) Sheds shall not be rented or inhabited.
7) Must meet and follow all conditions of ordinance:780-01
8) No accessory building shall be larger than 625 sq ft without site-plan approval
9) Not to exceed 16' in height at peak.
10)No other work shall be permitted (framing, plumbing, electrical and mechanical) unless
otherwise specified.
11) Accessory buildings in residential zones that exceed 150 sq ft shall be constructed of
masonry, wood frame, aluminum or vinyl. Aluminum and vinyl shall be residential grade
and be consistent with existing architecture of the principle building and adjacent
properties.
12) Fence shall not encroach neighbor's private property or right of way.
13)Fence shall be no taller than 6 feet in the rear and sides of home. 4 feet from the front
of home.
14)Good side of fence shall face out.
5UILCING. TIMS '
1660 DIXON AIRLINE ROAD.
AI JGU5TA, GA 36106
CITY OF ZEpHl'RNIL STIR ANCH Ord INC. PLANS
PLAN'
FOR THE
STATE OF FLORIDA
GENERAL NOTES_
1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL EXISTING CONDITIONS.
SHEET INDEX_. ,
2, THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ARCHITECTURAL AND STRUCTURAL DETAILS AND DIMENSIONS,ANY
DISCREPANCIES BETWEEN SUCH DETAILS AND DIMENSIONS SHALL BE REPORTED TO,THE ENGINEER PRIOR TO PROCEEDING WITH THE WORK. SHEET
3. THE CONTRACTOR SHALL BE'RE5PONSIBLE FOR ERECTION PROCEDURE AND SEQUENCE TO INSURE THE INTEGRITY OF THE BUILDING AND ITS SHEET TITLE
COMPONENT t?ARTS DURING CONSTRUCTION.'
: .NUMBER .- R-fir ...._v...:::..: :.. .
4. THESE PLANS HAVE BEEN PREPARED PER REGULATIONS OF THE 2014 FLORIDA BUILDING CODE.THE WORK OF ALL CONTRACTORS SHALL
COMPLY WITH THE REQUIREMENTS SET FORTH IN THE'AFOREMENTIONED CODE.NO DEVIATIONS FROM THE WORK.SHOWN OR REASONABLY A-t " .I^lIND Lf1AD'CHARTS EXP.'13" ! 1
IMPLIED SHALL BE UNDERTAKEN WITHOUT THE ENGINEERS WRITTEN GON5ENT-A COPY OF'McH WILL BE FILED WITH THE GONSTRUGTION
OFFICIAL.
5, ANY CHANGES TO OR DEVIATIONS FROM THESE DRAWINGS SHALL NOT BE MADE,WITI"T WRITTEN CONSENT FROM'THE ENGINEER., A-2 WIND LOAD CHARTS EXP.
6. THESE DRAWINGS ARE THE PROPERTY OF THE ENGINEER AND SHALL:NOT:BE'USEP*#THOUT H15,CON5ENT.'DRAWINGS SHALL NOT BE U5EDI. . ;' A-3 WIND MAP t LOADING DIAGRAM
FOR ISSUE OF BUILDING PERMIT UNLESS SIGNED AND,SEALED BY THE ENGINEER
h. THE OWNER AND THE CONTRACTOR SHALL HOLD HARMLESS THE ENGINEER FROM AND AGAINST ALL LIABILITY CLAIMS,DAMAGES,LOSSE5 A-4, GROUND ANCHOR SCHEDULE.,
AND EXFENSE5 INCLUDING;LEGAL"FEES ARISING OUT OF OR RESU.TING`FROM ERRORS OR OMISSIONS IN THE PERFORMANCE OF THE'WORK
BY THE CONTRACTOR. THE DRAWINGS SHOW THE GENERAL ARRANGEMENTS AND EXTENT OF THE WORK A5 THE WORK PROGRE55E5,THE 4-5.. . .BUCKLE.ANCHORING CHARTS EXP.8,
OWNER AND THE CONTRACTOR,AT NO EXTRA C4915,SHALL MAKE MODIFICATIONS TO MAKE THE PARTS ALIGN. A-6 BUCKLE ANCHORING CHARTS EXP.-'G'
0. DO NOT 50ALE DRAWIN65,ALL WRITTEN DIMENSIONS GOVERN,
q. THE CONTRACTOR FOR THIS PROJECT SHALL INCLUDE ALL MATERIALS AND LABOR REQUIRED TO COMPLETE THE TOTAL PROJECT.THE A-1 BUCKLE ANCHORING,DETAILS
CONTRACTOR SHALL FURNISH AND PAY FOR ALL MATERIALS,TOOLS,EQUIPMENT,LABOR MACHINERY,TRANSPORTATION,HEAT,WATER, A-8 AVTRM-b ANCHORING CHARTS EW.W
UTILITIES,AND ALL OTHER FACILITIES AND SERVICES REQUIRED FOR THE SAFE AND PROPER EXECUTION AND COMPLETION OF THE WORK.
THE,ENGINEER SHALL BE THE INTERPRETER OF 7HE CONTRACT DOCUMENTS. A-q AVTRM76 ANCHORING CHARTS EXP.'C'
10, THE DOCUMENTS SHOW ARE-AN OVERVIEW OF THE WORK REQUIRED UNDER THIS CONTRACT AND RELATED REQUIREMENTS AND CONDITIONS 2 A-IO .•_ AVTRM-6 ANCHORING DETAit;S,
THAT WILL IMPACT THE PROJECT.ALL DRAFUN55 ARE COMPLIMENTARY.THE DRAWINGS GENERALLY SHOW THE INTENT OF.7HE OVERALL
COMPLEXITY AND CONCEPTS OF THE PROJECT,AND DO NOT NECESSARILY SHOW ALL DETAILS AND CONDITIONS.ALL NEW INTERIOR A-11.. „ :AVt12X ANCHORING"CHARTS EXP."B', .
CONCRETE SLABS AND FOUNDATION WALLS.AND"FOOTINGS SHALL HAVE SOIL P0156NINO UNDER NEW WORK AND SHALL BE INSTALLED BY A
LICENSED CONTRAGTOR.`IN N0 INSTANCE SHALL FILL MATERIAL AND NATURAL SU•BORADE MATERIAL UPON WHICH FOUNDATIONS A IOR A-12 W,. .... AVTRX.WHORIN&CHARTS ..".G'•..
SLA59 ON GRADE ARE TO BE SUPFORTED BE COMPACTED TO A CRITERIA LESS THAN qA OF MODIFIED PROCTOR MAXIMUM DENSITY,, A-13 AV7RX ANGHOt21NG DETAILS'
UNLESS SPEGIFIGALLY.DIREGTED TO DO SO IN WRITING-BY A:PROJEGT GEOITGHNICAL ENGINEER
11. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING AND MAINTAINING ALL EXISTING SETBACKS,EASEMENTS,-AND ANY DEED , A-14 OPTIONAL PAD,DETAILS ;
RES ONS.
12. THEa 70R SHALL BE RESPONSIBLE FOR FINAL CLEANUP AND 5HALL INCLUDE THE SITE,AND THE BUILDING. THE ENTIRE
PROS IzEFt IN A NEW,.GLEAN CONDITION. I
:•j N®THE L S4Zo!��✓�[p �°/OD� - +,� cur "j 1
.... ; .
.: • REV BY DATE
THOMAS A.DIXONI P.E. * • EIENNETS EWII:DING.5Y5TEM5 SHEET
'AL4 BOW TW.10430" DIXON ENGINEERING,INC. � .` MASTER.ANCHORING PLANS DRN BYi CNO'
.SCM 215g2 VAS:045`13 5TRZTLRAI.ftINSKRW AV. O�i�_. _ .' �✓"!; 166o DIXON AIRLINE ROAD GHK BY, .TAD,.
WV+�071436 FLt 34222 IN5P6CTION-COA 81g5 � • .1 *`r.. i t-47$-552- WO�NO, 530 023 : co ;
�/ tI0
PA4 OlgWq K58 21ft 10410 MAIN STREET +► = , .ti
_ ;1N4 II2761 GAS OW II _TNONOT05ASSN FL 335g2 _ _♦ s • ''
F I -I u�_4ogos Aic�Ea a ei ..�!'& ::ON A:L' �+�' GovER SHEET - — --- — !'
pLA i
1040mwM Mminmon* |
� �m����V7�
^ "~^^ `~�" Phnmq5O�� � Fax,0.414.W6Regulation
|
Ken Lawson,Secretary Rick8cotkGovemor |
|
November m, zO16 /
Wayne Hartley �
mobmBuUders,zmc.-ox |
sszs. State St. |
Lyons,mxso4so |
RE: Manufacturer Certification,/oMAr za*V; Expiration Date: November 04,2019 |
|
Dear Wayne Hartley
It is my pleasure minform you that Robin Builders,Inc.'GA,located at 552S.State Street, |
Lyons,oxso4y6,has been approved under the Manufactured Buildings Program,a,provided
for under Chapter ss3' Part 1, Florida Statutes,uu manufacture Storage Sheds, Manufactured |
Buildings for installation inFlorida. |
Construction or modification on a manufactured building cannot begin until the Third Party �
Agency has approved the plans m accordance with the current Florida Building Code. Your Third
Party Agency is a contractor for the Department and has statutory authority and responsibilities
that must be met to maintain approved status.You may expect and demand quality plans
review and inspections. |
'
Each Code change will make your plans obsolete until they have been reviewed,approved and
indicated [on the cover page of the plans]for compliance with the Code by your Third Party
` Agency for plans review. Please ensure that your plans are in compliance and are properly `
posted on our website.All site-related installation issues are subject to the local authority
having jurisdiction.
The Department's contractor will make unannounced monitoring visits at least once each year.
You must grant complete access to your manufacturing facility and records to remain in |
compliance with the rules and regulations of this program. '
Your certification is approved for three years from this date.You will receive a renewal notice by /
Email generated bv the sCI5( for online renewal.If you have questions
you may contact Robert Lorenzo atoso-7z7-zn3so,our FAX mo5V-o1z-84n6.
Please visit our wobsiteat www.floridabuilding.ora to see valuable Information on the Florida
Manufactured Buildings Program. x copy of this letter must accompany applications for local
building permits,
Sincerely,
Robert Lorenzo
Manufactured Buildings |
cc:Professional Service Industries |
�
National Desigmarad inspection �
501 North Jackson Ave.Suite 2
Byars Building.
Russellville,AL 35653
July 25, 2015
Mr...Jim Richmond
Florida Department of Business and Professional.Regulation
Manufactured Building Program
1940 North Monroe Street
Suite 90A
Tallahassee, Florida'32399-0772
RE: Plan Approval:Residential Lawn Storage_Shed
Manufacturer:Bennett Building Syste ms
Plan NuMber/Name 530-022 Barn Shed
Dear, Mr. Richmond,
Pursuant to the requirements of the Florida Department of Business and Professional
Regulations,.the above referenced documents have been reviewed for compliance with:
2014 FBC,.5th Edition
These plans comply with Florida Product Approval Rule 61G20-3.006 (FAC).Also included in this
approval and attached to the plans s.pre-engineered truss design D1056903, Kingpost,Job.
#79092. .
A signed and sealed set of plans are maintained on file in the Third Party Agency office of
National.Design and Inspection.
All mandatory comments have been satisfied and plans are approved for construction by a
modular building manufacturer that is currently approved by the Department of Business and
Professional Regulations:
i
If you have any questions or require my assistance in.any way, please do not hesitate'to contact
me.
Respectfully submitted,
r
John Farinelli, CBO, MCP,SMP49
t; ,
V,
AREA FOR APPROVAL STAMPS
1660 DIXON AIRLINE ROAD
.,;a--v?i,---vV DACE 4"COMAENT
CITY OF ZEPHYRRILLE
BARN SHED PLANS PLMNS
'
�
�
�
'
�
� FOR THESTATE OF
|
2 BUILDIN&CATE&O T ===JFF- SHIET LIST TA5Lrz
4. INT.PRESSURE COEFFICIENT 10.18
5. ENCLOSURE CLASSIFICATION ENCLOSED G-I COVER SHEET
0. FLOOR DESIGN LIVE LOAD 40 F5r
q. ROOF DESIGN LIVE LOAD 20 FSr C-6 FASTENIN6 56HEMLE
ROOF DESIGN DEAD LOAD l FSF
p o. KbLL DES16N DEAD LOAD 5 F5F A-1 FLOOR AND ROOF FRAMINC,PLANS
:1 LOFT UNINHABITABLE LIVE LOAD 20 P5F I I e
5 CONSTRUCTION TYPE ELEVATIONS
A-4 HALL 5EOTION DETAILS
15. FIRE RATING EXT.KALLS WA
A-,� ENDNALL FRAMING,DETAILS
'a :"T. THE CONTRACTO"ANUFACTURER.MET
COMPLY KTH THE FOLLOAIN&CODES AND
ALL OF THERE AMENOMENT5/5UFPLEMENTS: A-q KALL SECTION DETAILS
A-10 DETAILS
-NATIONAL ELECTRIC CODE--2011 A-11 DETAILS
-NFPA 101 LIFE SAFETY CODE-2012 A-12 KALL SECTION DETAILS
NOTE: A-15 DETAILS
MAWFACTURE To HAVE LIST AVAILABLE TO 004pw�w
ORD PARTY'INSPECTOR T14AT MEETS THE V41NO
PRESSURES STATED ON G-2 FOR ANY
PRODUCT THAT REOUIPE5 PRODUCT APPROVAL NATIONAL ELeCTW,; WOR,
FOR THE STATE OF FLORIDA oj�z
AND THE f�17v-
ORDINAI
V Y DATE DESCRIPTION
THESE PLANS NERE DE516NED IN ACCORDANCE NITH THE 2014 FLORIDA BUILDIN6 CODE,BUILDIN&Fojj�-
THOMAS A. DIXON, REW EARN SHED PLANS
CHE(KED BY, TAD
PHONE:1-41D-552-111*7
�
!
�
|
i
City of Zephyrhills
BUILDING PLAN REVIEW COMMENTS
Contractor/Homeowner:
Date Received: c�5
Site: J� �� a ka A-e
Permit Type: d I&C l`j x ,�h
Approved w/no comments:❑ Approved w/the below comments: Denied w/the below comments: ❑ ;
i
i
i
This comment sheet shall be kept with the permit and/or plans.
Kalvin Switzer lan xaminer Date Contractor an or Homeowner
(Required when comments are present)