Loading...
HomeMy WebLinkAbout18-19904 CITY OF ZEPHYRHILLS 5335-8TH STREET , - (813)780-0020 19904 BUILDING PERMIT PERMIT INFORMATION = LOCATION INFORMATION Permit Number: 19904 Address: 3934919TH AVE Permit Type:- ADDITION/ALTERATION . ZEPHYRHILLS, FL. Class of Work: 434-ADD/ALT RESIDENTIAL Township: Range: Book: Proposed Use: NOT APPLICABLE Lot(s): ! Block: Section: Square Feet: Subdivision: SUNSET ESTATES Est. Value: Parcel Number: 12-26-21-0300-00000-0110 Improv. Cost: 14,000.00 OWNER INFORMATION Date Issued: 7/10/2018 Name: ANDERSEN, JOHN & DONNA Total Fees: 300.00 Address: 2996,COATES RD Amount Paid: 300.00 ZEPHYRHILLS, FL. 33542 Date Paid: 7/10/2018 Phone: (315)536-6619 Work Desc: CONSTRUCT 21 X 20 ROOM ADDITION i ; CONTRACTORS APPLICATION FEES HOMEOWNER BUILDING FEE : 165.001 HOMEOWNER ELECTRICAL FEE 67.50!' HOMEOWNER MECHANICAL FEE 67.50 i Ins ections.Re uired FOOTER 2ND ROUGH PLUMB MISC INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80(2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or, first reinspection,whichever is greater,for each such subsequent reinspection. ! NOTICE: In addition to the requirements of this permit, there maybe additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental' entities such as Water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. j NO OCCUPANCY BEFORE C.O.; ; i CONTRAC OR SIGNATURE PERMIT OFFI R PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: Date Received.: CP- 2-0 —l Site: ` T y r Permit Type: zz )C 7V x�n- c Approved w/no comments:❑ Approved w/the below comments: ❑ Denied w/the below comments: ❑ I. This comment sheet shall be kept with the permit and/or plans. i &fl7-2 Kalvin Swit'zpl6s Examiner Date Con actor an or Homeowner (Required when comments are present) I 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received 7Hd .7 Phone Contact for Permitting - Owner's Name �[ -e lall 01f6/ Owner Phone Number 5,?10 Owner's Address +k G2°. Z!C L IS �3 Owner Phone Number, Fee Simple Titleholder Name Owner Phone Number' i Fee Simple Titleholder Address '/ J JOB ADDRESS LOT III hh SUBDIVISION •f ES144,sl PARCEL ID# 01•�?!j o� �3Q� 7�(�U/Q'U�� (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED B NEW CONSTR ADDIALT = SIGN = = DEMOLISH INSTALL REPAIR PROPOSED USE = SFR 0 COMM = OTHER TYPE OF CONSTRUCTION = BLOCK Q// l/FRAME Q STEEL Q DESCRIPTION OF WORK a C`/!7 /d YL BUILDI IZE 1 -2/ aCJ SQ FOOTAGE L/ HEIGHT aP ��1��1'•�'1.9•'�1'9��Fa'PF�P�r�F'r1�rTPTT�7°�r�TITI"9"9"•PTP'�PTTP�1��f�F�i`T' UILDING $/ QQ� /r)\ VALUATION OF TOTAL CONSTRUCTION Juke `e,0 ELECTRICAL $ AMP SERVICE Q" PROGRESS ENERGY = W.R.E.C. =PLUMBING $ 19 e6� MECHANICAL $ VALUATION OF MECHANICAL INSTALLATION =GAS = ROOFING 0 SPECIALTY = OTHER v� FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO BUILDER , l� PAN.Y SIGNATURE REG/ISTERED Y/ N FEE CURREN Y/N Address S/9 �'1' lam. G!?( S 3e.�(( License# ELECTRICIAN COMPANY SIGNATURE REGISTERED I Y/ N FEE CURREN Y/N Address ��% lily• GJ(� S 3 � License# PLUMBER COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Address r License# l MECHANICAL COMPANY ,1' SIGNATURE //�� (� �• / REGISTERED Y/ N FEE CURREN I Y/N Address License# OTHER COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN I Y/N Address License# IIIIIIIIIIIIIIIIIIIIIIIIII11111IIIIIIIIIIIIIIIIIIIIIII1111 [ IIIltlll ' RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal dale. Required onsite,Construction Plans,Stonmwater Plans w/Silt Fence Installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ""PROPERTY SURVEY required for all NEW construction. Direct-.1-f.-1-f.-1-.f-f-i-{-1-I-H-4.1-�4.1-1-F i-1--1-1-•k-f-f-4-i-i-A-t-�1�1.-I-1--L-1-4 F-f.a<Ff�-i-1•1-f.�1-1-1-F-8-1--�I�faf-a-4-1-• Directions: Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500) Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from caner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways.needs,ROW Y . i June 15, 2018 To the City of Zephyrhills Building Department. I Donna Andersen give Kathy Mims with FBC Plans and Engineering permission to drop off and pick up my permit for my room addition. Donna Andersen OWNNotary Public State of Florida Nancy J Brooks My Commission GG 178530 jMR Expirea02/1812022 64 i DISCLOSURE STATE PT FOR. Owfm CITY OF zxpHymaLLS BUILDING DEPARTkmT have read and fully understand and agree to the provisions of this instrument. The undersigned states and affirms that he or she is desirous of constructing, renovating,, adding to or reroofing his or her own domicile, that he or she actually occupies, or will occupy by said domicile, and same Is not for rent, lease or sale. That he or she shall comply with the following conditions .- I. That the owner and he or she alone shall act as the builder for all phases of Construction. I 2. That the owner will comply with all provisions of the�City of Zephyrh:Llls ordinam so and codes pertinent to the building. 3. That in the event various phases of construction are subcontracted, he will engage only properly licensed subcontractors*and will:personally supervise such work. 4. That in the event the Building Inspector oba-11 requIrs corrections to 'be made, the owner will assume full responsibility to insure they. are .made, and upon completion will call for a reInspectIon before proceeding with the building. 5. That the owner.shall assume full responsibility for the construction and will not expect supervision of his work from the City of Z6phyrhills Building Department. 6. That prior to final inspectIon,any additional fees, including re±uspectlon fees, must be paid in full. A written request from this office shall constitute an official notice to pay additional fees 7. That the owner shall comply with all City,' State and Federal laws in regard to social security, workman's compensation, lien laws, etc., where applicable- 8. That the owner shall comply with all the safety codes issued by the Florida Industrial Commission. 9. State law requires constructIon, to be done by licensed contractors. You have applied for a permit under an exemption to that law. The exemption allows you, as the owner of your property, to act as your own contractor with certain restrictions even though you do not have a license. You must provide direct onsite supervision of the construction yourself. You;may build or Improve a one-family or two-family residence or a farm outbuilding. You may also build or improve a commercial building, provided your costs do not exceed $25,000. The building or residence must be for your own use or,occupancy. It may not be built or substantially improved for sale or lease. ' If you sell or lease a building you have built or.substantially Improved yourself within I year after the construction is complete, the law will presume tdiit you built or substantially improved If for sale or lease, which Is a violation of this exemption. You may not hYare an unlicensed person to act as your contractor or to supervise people working on your building. It Is your responsibility to make sure that people employed by you have licenses required by state law and by county or municipal licensing ordinances. You may I not delegate the responsibility for supervising work to a licensed contractor who is not licensed to perform the work being done. Any person working on: youiz building who is not licensed must work under your direct supervision and must be employed by you, which means that you must deduct F.I.,CAL. and withholding tax and provide workers, compensation for that employee, all as prescribed by law.- Your construction mint comply with all applicable laws, ordinances, building codes, and zoning regulations. �7/ /S_ 0MMIS SIMMTURW DATE 4 . Ay ADDRESS Zqy!k�19 ewft PHOM WITNESS. 1 PERMIT # Building Department Date Received ✓ Phone Contact for F' 'ft* ( API 7H -53'P( & A Owner's Name d9— a—a -ep—,4Z&le�t— Owner, PhoneNumber 131s— 6&1 f Owner's AddresS IrJIS Owner Phone Number Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address JOB ADDRESS LOT It SUBDIVISION YM 14-of iijs��,4es PARCEL IDAF/ --26-02 e6&JO-I61167 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED NEWCONSTRF;—,K ADD/ALT SIGN DEMOLISH R INSTALL F-1 REPAIR PROPOSED USE = SFR 0 COMM = OTHER TYPE OF CONSTRUCTION = BLOCK Q FRAME STEEL DESCRIPTION OF WORK y=BUILDI IZE SQ FOOTAGE[ a. HEIGHT -r* , I r-r"r . . . . . . . I I I UILDING VALUATION OF TOTAL CONSTRUCTION ZJ 6 1 it 0 AMP SERVICE PROGRESS W.R.1 ELECTRICAL $ EC =PLUMBING IS VALUATION OF MECHANICAL INSTALLATION =GAS = ROOFING Q SPECIALTY = OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I" . . . . . 44_; .4.4— BUILDER COMPANY I WUA&t)&�V7 Lo 1'% SIGNATURE yt REGISTERED Y/ N FEE CURREN Address License ELECTRICIAN COMPANY EaJ;P41'ell, 16 SIGNATURELEI REGISTERED YJ N FEECURREN LI_LN J Address 44 2WAS License# F PLUMBER COMPANY SIGNATURE REGISTERED I YIN FEECURREN Lyl N_J Address I License# MECHANICAL COMPANY EM:' e47kJ-'-'7 L SIGNATURE REGISTERED YJ N FEE CURREN Y/N Address License# OTHER COMPANY SIGNATURE REGISTERED Y/ N FEECURREN Address License# RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsits,Construction Plans,Stormwater Plans wt Silt Fence installed, Sanitary Facilities&1 dumpster,Site Work Permit for subdivisionsliarge projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans wl Silt Fence Installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plan$. —PROPERTY SURVEY required for all NEW construction. . . . . . . . . . . Directions: Fill out application completely. Owner&Contractor sign back of application,notarized if over$2500,a Notice of Commencement is required. (A/C upgrades over$7500) Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized lettei from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter,!on oublk;roadways..needs'ROW NORTH PROPERTY LINE 68'-O" r-------------- ------------------------------- --------------------� I I I I I I I I I I I I I I I I 4 I I , I I I � I I I _ I I I I I I I I I 4 I I 1 I I I I I I I I I I I I j NEW FAMILY ROOM Q I I 1 I I I ' I I ' I I I i I I I 1 = OI 10 O � � 0 Lu j w zl Iz w EXISTING HOUSE fL 1 0- to I N W I I I I I I IZ'-9' 45'-4- I J I I , I I I I I 40-I° 4 0 14 I I J I J I J I I I O 1 I I I I I i I Q i I � SCALES I'0 10'-O" i I I i I I I I JOB NAME and ADDRESS I JOHN K and DONNA K ANDERSEN J I 3934E Sth AVE I ZEI-HYRHILLS,FLORIDA I 33542 L------------- ------------------------------ ------ ----------- SOUTH PROPERTY LINE &&'-O" ]FBCC ]CLANS & ENGINEERING SERVICCE9 INC. David W. Smith, M.S., P.E. 6272 A BOTT STATION DR., UNIT boll 813-788-5314 /Z]EP H[SYRHIL LSy FL. 33542 1-866-824-7894 www.fbeplans.com e-mail: dwsflpe@eartllnllnnnk.nae>t June 26, 2018 To Whom It May Concern: Re: Change of Exterior finish on Room Addition for Job Wddress: 39349 9t"Ave., Zep)hys,F.1,I. Job Na_rne�A�ndelsoi�� t '�'� Contractor: Owner, Anderson This letter is to certify I have been notified by the Owner, Donna Anderson, that due to their home location in the CRA district of Zephyrhills, and vinyl siding not being an acceptable siding for that district, they will change the exterior finish for the exterior walls of the Room Addition to Stucco. r Please accept this letter as an addendum to the plans Engineered by me, for the above mentioned Room Addition per the Stucco attachment notes below. STUCCO EXTERIOR FIN16H WHERE CEMENT PLASTER (STUCCO) IS TO BE APPLIED TO LATH OVER FRAME CONSTRUCTION MEASURES SHALL BE TAKEN TO PREVENT BONDING BETWEEN THE CEMENT PLASTER AND THE WATER-RESISTIVjE BARRIER!A BOND BREAK SHALL E3E PROVIDED BETWEEN THE WATER RESISTIVE-BARRIER AND THE CEMENT PLASTER CONSISTING OF ONE OF THE FOLLOWING-. IJ TWO LAYERS OF AN APPROVI=D WATER-RE51STA45B RRIER MATERIAL. I 2) ONE LAYER OF AN APPROVED WATER-RESISTANT BARRIER OVER AN APPROVED PLASTIC HOUSE WRAP. The above application will mee FBC 6th Edition, and ASCE 7-10, for the Risk Category II, 1 ult/110a Wind Speed in Exposure B. espectfully, ► 7 O Al •••••coa•Q• A �Cy • ?i No.53608 00 David W. Smith, P.E. #53608 O �S7ATE OF a��t�`�;•���RiDP`••: ����°: fie? S •••oeoo••• ��, go0y �' ` NA 0A �V �zi4 FBC Plans% IIIIIIIIIIIIIIIIIIIillllllllllllllllllllllilllllllllllllllll Florida &Engineering 2018110096 6272 Abbott Station Dr. j Brrrilding Unitlol rode ZephyrhiUs,FL 33542 Repl:1970081 Ree: 10.00� DS: 0.00 IT: 0.00 Permit No. Parcel IDNo_ 06/29/2018 D. B., Dpf.V Clerk NOTICE OF COMMENCEMENT State of �lDri Cd�, County of �u s 6V THE UNDERSIGNED hereby gives notice that Improvement wig be made to certain real properly,and In accordance with Chapter 713,Florida Statutes, the following Information is provided In this Notice of Commencement: 1. Description of Property:Parcel Identification No. -2 I 'e;dO—D0000 StreetAddress: 3193111 9 ,.Ap' r 4.`j4 LAC • 33 Kq — 2. General Description of Improvement - I 3. Owneerr Information or L ee Information if the Lessee contracted for the Improvement: �i'Tf�.�iP/S Address Cl Stale a Interest In Property: 6 i Name of Fee Simple Titleholder. (If different from Owner listed above) Address n f ` -JL*Y,P LA. CIcitystate. 4. Contractor 9A lffA (`r 39;? Ile 7�nG �I1���� ►G'c 33V% Address Cityp State Contractor's Telephone No.: 6. Surety. Name Address PRULR 5.0'NEIL,Ph.D.PR5C0 CLERK 8 COt1PTROLLE r 06/29/2018 0 .43 FG 'o state inAmount of Bond:S OR 6K g-46 .6. Lender. Name Address City State Lender's Telephone No.: 7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)(7),Florida Statutes: j Name Address City Stale I, ' Telephone Humber of Designated Person: 8. In addition to himself,the owner designates of to receive a copy of the Uenoes Notice as provided In Section 713.13(1)(b),Florida Statutes. Telephone Number of Person or Entity Designated by Owner: 9. Expiration date of Notice of Commencement(the expiration date may not be before the completion of construction and final payment to the contractor,but wig be one year from the date of recording unless a different date Is speciff": WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION, IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. -- Under penalty of per)ury—I Eeaam that I have lead the foregoing notice of commencement and that the(ads stated therein are true to the best of my knowledge and belief. STATE OF FLORIDA COUNTY OF PASCO /�/l1AA IA�II M l Signature of Owner or Lessee,or Owner's or Lessee's Authorized OHicer/Diredor/Partner/Manager 4 Signetoys TtilelO(fice I. �, The foregoing instrument was scimowledged before me this al q day of U G ,20 L,by ?n n. is ge*7 j es (type of authority„e.g.,officer,trustee,attorney In fact)for (name of party on behalf of whom instrument was executed). Personally Known[3.M Produced Identification Notary Signature I . Type of Identi ication Produced Ft brf✓C✓S L/C en SL Name(Print) . L014 � � Wty Canrrrieslon Oq 17tIS30 - q� Er�llrta 07/1tIl�2 wpdatwbes/nobwcommencemen(yc053t148 j FORMS I FLORIDA BUILDING CODE, ENERGY CONSERVATION n Residential Building Thermal Envelope Approach 0 FORM R402-2017 Climate Zone ❑ Scope:Compliance with Section R401.2(1)of the Florida Building Code,Energy Conservation;shall be demonstrated by the use of Form 0 R402 for single-and multiple-family residences of three stories or less in height,additions to existing residential buildings,alterations, renovations and building systems in existing buildings,as applicable.To comply,a building must meet or exceed all of the energy efficiency requirements on Table R402A and all applicable mandatory requirements summarized in Table R402B of this form.If a building does not comply with this method,or by the UA Alternative method,it may still comply under Section R405 of the Florida Building Code,Energy 0 Conservation. PROJECT NAME Nt_)k Sg BUILDER: OW E AND ADDRESS: ,3L137L 9 9'`�-4gF /V ,Q / / E OWNER: Z�P�YRfflLGS FG. 335_V2 PERMITTING OFFICE: e l�Pr�� �GLcI (] < JURISDICTION NUMBER: (p[L O'OffN )l DONI Ill- A-/VAFR-54R) PERMIT NUMBER: General Instructions: 1.Fill in all the applicable spaces of the"To Be Installed"column on Table R402A with the information requested.All"To Be Installed"values must be equal to or more efficient than the required levels. 2.Complete page 1 based on the"To Be Installed"column information. 3.Read the requirements of Table R4029 and check each box to indicate your intent to comply with all applicable items. 4.Read,sign and date the"Prepared By"certification statement at the bottom of page 1.The owner or owner's agent must also sign and date the form. I 1. New construction,addition,or existing building 1. 2. Single-family detached or multiple-family attached 2. �51',n4E 3. If multiple-family,number of units covered by this submission 3. 4. Is this a worst case?(yes/no) 4. O 0 5. Conditioned floor area(sq.ft.) 5. 6. Windows,type and area /l a) Lffactor: 6a. •7 0 /3 l;l. a b) Solar Heat Gain Coefficient(SHGC) 6b. a6_min. c) Area 6o. R 7. Skylights (I a) U-factor: 7a. N/1 b) Solar Heat Gain Coefficient(SHGC) 7b. 8. Floor type,area or perimeter,and insulation: 0 a) Slab-on-grade(R-value) 8a. b) Wood,raised(R-value) Sb. a c) Wood,common(R-value) 80. d) Concrete,raised(R-value) 8d. e) Concrete,common(R-value) 8e. Q 9. Wall type and insulation: 8 a) Exterior: 1. Wood frame(Insulation R-value) 9al. R-�3 2. Masonry(Insulation R-value) 9a2. b) Adjacent: 1. Wood frame(Insulation R-value) 9bl. 2. Masonry(Insulation R-value) 9b2.10. Ceiling type and insulation a) Attic(Insulation R-value) 10a. R-3 D b) Single assembly(Insulation R-value) i0b. 11. Air distribution system: a) Duct location,insulation iia. ie, B b) AHU location lib. EXI 5T/V6 c) Total duct leakage.Test report attached. 110. cfm/l00 s.f. Yes❑ No Zr 8 12. Cooling system: a)type 12a. EXIST/NCv b)efficiency 12b. 13. Heating system: a)type 13a. FJC r 577AAL1, b)efficiency 13b. Qi 14. HVAC sizing calculation:attached 14. Yes❑ No® 8 15. Water heating system. a)type 15a. R` b)efficiency 15b. 1 hereby certify that the plans and specifications covered by this form are Review of plans and specifications covered by this form indicate in compliance with pre Florida Building de, nergy Conservation. compliance with the Florida Building Code,Energy Conservation.Before 0 PREPARED BY: ? Date 6-/8-r8 construction is complete,)this ilding will be inspected for compliance in 1 hereby certif that thi uilding is in compliance with the Florida Building accordance with Secti 3 ,F.S. Code,Energy Conservation. CODE IC L: OWNER/AGENT: Date: Date: - 0 I FLORIDA BUILDING CODE-ENERGY CONSERVATION,6th EDITION(2017) R-55