Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
18-19908
CITY OF ZEPHYRHILLS /�' 5335-8TH STREET (813)780-0020 19'08 BUILDING PERMIT PERMIT INFORMATION = LOCATION INFORMATION Permit Number: 19908 Address: 7403 GALL BLVD Permit Type: COMMERCIAL ZEPHYRHILLS, FL. _ Class of Work: ADD/ALT COMMERCIAL Township: Range: Book: Proposed Use: COMMERCIAL Lot(s):. _ Block: Section: Square Feet: Subdivision: CITY OF ZEPHYRHILLS Est. Value: Parcel Number: 34-25-21-0000-00300-0020 Improv. Cost: 150,000.00 OWNER INFORMATION Date Issued: 7/18/2018 Name: ZEPHYRHILLS MERCHANT SQUARE LLC Total Fees: 1,365.00 Address: 800 HIGHLAND AVE STE 200 Amount Paid: 1,365.00 ORLANDO, FL 32803-3907 Date Paid: 7/18/2018 Phone: Work Desc: INTERIOR REMODEL-PT SOLUTIONS CONTRACTORS APPLICATION FEES ABI COMPANIES,INC. BUILDING FEE 817.50 ENVIRONMENTAL DESIGN SOLUTIONS W ELECTRICAL FEE 247.50 ALLIANCE POWER SOLUTIONS INC PLUMBING FEE 172.50 JA GREEN PLUMBING & MECHANICAL I MECHANICAL FEE 127.50 \l� I C�sb Ps ections Required FOOTER 2ND ROUGH PLUMB MISC INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection. NOTICE: In addition to the requirements of this permit, there maybe additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. &k. SIGNATURE PERMIT OFFI R PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed"restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work,they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation Linder state.law. If the qviner or Intended contractor are uncertain as to-what licensing requirements may Apply for the intended work,they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. !Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the"contractor Block"of this application for which they will be responsible. If you,as the owner sign as the contractor,that may be an indication that he Is not properly licensed and is not entitled to permitting privileges in Pasco County. TRANSPORTATION IMPACTIUTILITIES IMPACT AND RESOURCE RECOVERY FEES: The undersigned understands that Tr?tnsportation Impact Fees and Recourse Recovery Fees may apply to the construction of new buildings,change of use in existing buildings,or expansion of existing buildings,as specified in Pasco County Ordinance number 89-07 and 90-07,,!as amended i' The undersigned also Understands,that such fees,as may be due,Will be identified at the time of permitting.. It isfurther understood that Transportation Impact Feesand Resource Recovery Fees must be paid prior to receiving a certificate of occupancy'or final power release. If the project does not involve a certificate of occupancy or final power release,the fees must be paid prior to permit issuance. Furth6rrhore, if Pasco County Water/Sewer Impact fees are due' ordinances: 9 they must be paid prior to permit issuance in accordance with applicable Pasco County CONSTRUCTION LIEN LAW(Chapter 713,Florida Statutes,as I amended): If valuation of work is$2,500.00 or more,I certify that 1, the applicant have been provided With a copy of the "Florida Construction Lien Law—Homeowners Protection Guide"prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner",I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner'prior to commencement. CONTRACTOR'SIOWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work Will be done in compliance with all applicable laws regulating construction,zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to'meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the I intended work,and that it is my responsibility to identify what actions I must take to be In compliance. Such agencies include but are not limited to: Department of Environmental Protection-Cypress Bayheads, Wetland Areas,and Environmentally Sensitive Lands,Watdr/Wastewater Treatment.- Southwest Florida Water Management District-Wells, Cypress Bayheads, Weiland Areas, Altering Watercourses. Army Corps of Engineers-Seawalls,Docks,Navigable Waterways. Department of Health & Rehabilitative Serviceig/Emif6rimental Health Unit-Wells, Wastewater Treatment, Septic Tanks US Environmental'Protection'Agency-Asbestoi'a6afement. Federal Aviation Authority-Runways. I understand that the following-restrictions apply to the use of fill: Use of fill is not allowed in Flood Zone"V"unless expressly permitted. If the fill material.is to be,used in Flood Zone "A", it is understood that a drainage plan addressing a compensating volume"will be submitted at time of'permitting-which is prepared by-a professional engineer licensed by the State of Florida. If the fill material is to be used in Flood Zone"A" in.connection With a permitted building Using,stem wall construction,I certify.that fill will be used only to fill the area within'the'stern wall. If fill material is to be used In any area, I certify_that Use of-such fill will not adversely affect adjacent properties. if use offill is found to adversely affect adjacent properties,the owner may be cited for violating the conditions of the building permit issued under-the:attached permit application,for lots less than one(1) acre which are elevated by fill,an engineered drainage plan pis required. If I am the AGENT FOR THE OWNER,I promise in good faith-to inform,the-owner of the permitting conditions set forth in this affldavlt.prior-to commencing construction. I understand that a-separate permit maybe required for electrical 1work, plumbing, slgfis,-Wells, pools, air conditloihft, gas,be,other InstaIIatIohs'h6t'§pbbfficaIIy included in the applicatl6n. A permit,Issued,shall be.construed.to be a.license to proceedwith the work and not as authority to violate,cancel,alter,or set aside any provisions of the technical codes,fiof shall issidanw of a permit prevent the Building-Official from thereafter " requiring a correction of errors in-plans,construction or violations codes. Every permit Issued shall become ni of"' 6alld unless the work authorized by,such permit is Commenced Within six months I of permit issuance,or d work authorizeby the per it is suspended or abandoned for a period of six(6)months after the time the work is'commenced. An extension -may be-requested,.i.n writing,from the Building Official for�p'e'rlbd'not to exceed ninety(90)days and will demonstrate justifiable bause,for the extension. If work ceases for ninety(90)consecutive days,the job is considered abandoned! WARNING30 OWNER::,YOUR FAILURETO RECORD A,NOTICE OF-COMMENCEMENT MAY RESULT IN YOUR 'kbVgMENtS**d YOUR OR60tikTy..IF YOU INTII FINANCING,tc*ULT PAYING TWICE FOR IMP Ekb,tO OBTAIN WITH YOURLENDER OR AWATTORNEY BEFORE RECORDING YOUR NOTICE 60 COMMENCEMENT. FLORIDA JURAT(F.S.117.03) OWNER OR AGENT CONTRACTOR Subscribed and sworn to(oraffirmed).before me this Subs0bedand AwA1fp,(oriffIfmed)b 'WFo—islare personally known to me or hasihave produced Who is/are personally known to me or hasthave produced as identification. asidentification. _-_Notary Public Notary Public Commission No Commission No Name of Notary typed,printed or stamped Name of.Notary typed,printed or stamped • 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received `J L` III, _09 Phone Contact for Permitting � irrrrrr rrrr Owner's Name n `` \-Nl2Sc�a S�uCi� Owner Phone Number Owner's Address OCO \,'& llr�t2CJ a ` Owner Phone Number Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address \ JOB ADDRESS LOT# SUBDIVISION i PARCEL ID#F3 21-03CO-CAZ O� -0132-0 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED e NEW coNSTR e ADD/ALT SIGN 0 0 DEMOLISH INSTALL REPAIR PROPOSED USE = SFR 0 COMM = OTHER TYPE OF CONSTRUCTION = BLOCK Q�� FRAME Q STEEL Q DESCRIPTION OF WORK BUILDING SIZE SO FOOTAGE= HEIGHT BUILDING $ t 0 t,0oz> VALUATION OF TOTAL CONSTRUCTION [ELECTRICAL $ZSrcoO AMP SERVICE _ _ PROGRESS ENERGY = W.R.E.C. E2fPLUMBING $ 15 ' OO MECHANICAL $ n f10O0 VALUATION OF MECHANICAL INSTALLATION "(J =GAS =-1 ROOFING SPECIALTY 0 OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO BUILDER t I COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Y/N ^ Addres License# 1LECTRICIAN COMPANY SIGNATURE V•YA �+ \' REGISTERED Y/ N FEE CURREN Y/N ddress i License# •y�} �( PLUMBER (` t COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Y/N ddress License# MECHANICAL � " '+ r COMPANY p/Y(!�l�O vr/LE�/�L �ESyI-y So -Ty� SIGNATURE p REGISTERED Y/ N FLE CURREr I Y/N Address G- JC p z ✓� License# OTHER COMPANY SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address License# RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stommwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster;Site Work Permit for subdivisionsAarge projects .COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Fortes.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stornwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. —PROPERTY SURVEY required for all NEW construction. rr � rrns� r � rrrrrrrrrr � ri � rrrrrrrrrrrrrrrrrrrrrrrrr � rrrrrrrrr � r � rrrr � � r � t Directio : Fill out application completely. Owner&Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500) Agent(far the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW ` �=ras3g"tK. � :�y"ars�,�kv'".ztx'S�t :k',.�". ':��k�`n�-'��kY;$ {'»��''.• ' y •i x ,G ', !?ea3i�$1�Qt+��i111Ye'!• �+, ':gWMbl'i�+w,NtA�1167`� �. i' 'W1Ms.VifKpiMf• .1 '� �• r �. .� 4 • '� _� .-�l � � 'SGp►Ld,,.,�.r. „` �b�'�ti:� '�; ``�'Jr���� }�ry� e�bIDIY t y��yry( .. ��� � '�tlF146�frht�lG1H$t7iLt�'l#�i'.G .. r y�izN .r6Clrrfeie�d w....�Z .ww _ fi�tir.� lk��l�gF'l�� i1�k�:i�� �!�:�'�`+�i�fiiClut�iiritaib�n+atl�ii•' °"' ,'' '. `• ', :�bptCl� '�H!�ql'��pIMA�iilA��tw ' b1��tYf��ht�GE � spy'• Kd�'+'�'��r• ° rl� .1�flIYd�R�EV�++tla�itt►YtlNeYY. • �;;' yy��6dSYf4rift#1 '4;, dDl�1� 34 u�l��'d�'�+d+�ip�{�: •, '... ::�tia V�toitidFt�...r,. ., ►66iabaes, .. v ��oi� l�F�ksoni++pw�.i ► R � i City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: r-OZL46LX-4 Date Received: ( Site: la,D Q-CLU t Permit Type: �j77 �'r'?(�d A`vcdej- Approved Who comments:EV Approved w/the below comments: ❑ Denied w/the below comments: ❑ This comment sheet shall be kept with-the permit and/or plans. 16 . )VI , Kalvin Switzer-Pl xaminer Date Contractor and/or Homeowner (Required when comments are present) x E UNIVERSAL ENGINEERING SCIENCES, INC. 9802 Palm River Road Tampa, FL 33619 Phone: 813-740-8506 Fax: 813-740-8706 Private Provider Plans Compliance Affidavit Private Provider Firm: Universal Engineering Sciences, Inc. Private Provider: Mark K Hardy, P. E. Address: 9802 Palm River Road Tampa, FL 33619-4438 Phone: 813 740 8506 Fax: 813 740 8706 Email: Tam pal nfo(a-)Universal Engineering.com Project Name: PT Solutions-Zephyrhills-7403 Gall Blvd, Zephyrhills, FL 33541 Sheets: A-0,A-1, A-2, F-1, M-1, M-2, E-1, E-2 E-3, P-1, P-2 I hereby certify that to the best of my knowledge,information,and belief the referenced plans submitted were reviewed for,and are in compliance with,the Florida Building Code and all local amendments to the 2017 Florida Building Code by the following affiant,who is duly authorized to perform plans review pursuant to Section 553.791, Florida4S%�ftlqngQQlds the appropriate license or certificate. The design professional is responsible to make any necessary adju s-en�gFp'(6y ions to ensure code compliance. >>� Q. .••°•• ��.99 •. Mark K Hardy, P. E. No.57233 Signature: - afe:S• �� Private Provider STATE OF • O•°• -ZOR10'°•�� �� S/ONAI.ENG����� State of Florida, County of Hillsborough, li 11 SWORN AND SUBSCRIBED before me on the day of ,2018 by Mark K Hardy being personally known to me and who being fully swom and cautioned, state.that the fo egoing is true and correct to the best of his/her knowledge or belief. e�69111111111//0� v���'0p\PEE RI VFW// •�,Missl%•.• > Diane Rivera cj 20 aty , FAA o 0 Signature of Notary ro e printed Name e• #FF 920274 :Qg Notary Public: NOTARY STAMPST �9�°•®ro. ��rN ,,;oQ 6t0/II0Cli11011� UNIVERSAL ENGINEERING SCIENCE, INC. 9802 Palm River Road Tampa, FL 33619 Building Inspection Department Manager: George Dixon Phone: 813-740-8506 Fax: 813-740-8706 TamoaBID(@UniversalEnaineerina.com Notice to Building Official of Use of Alternative Provider Project Name: PT Solutions-Zephyrhills Parcel Tax I.D.: Services to be Provided: Plans Review Inspections 1, Robert.Ford (PT Solutions) the fee owner, affirm I have entered into a contract with the Private Provider Indicated below to conduct the services indicated above. Private Provider Firm: Universal Engineering Sciences, Inc. Private Provider: Mark K Hardy P. E. Address: 9802 Palm River Road, Tampa, FL 33619 Telephone: 813-740-8506 Fax: 813-740-8706 E-mail Address(Optional): TampaBID(o)universalengineerinq.corn Florida License, Registration or Certificate No.: Professional Engineer-Florida License No. 57233 1 have elected to use one or more alternative providers to provide building code plans review and/or inspection services on the building that is the subject of the enclosed permit application, as authorized by S.553.791, Florida Statutes. I understand that the local building official may not review the plans submitted or perform the required building inspections to determine compliance with the applicable codes, except to the extent specified in said law. Instead, plans review and/or required building inspections will be performed by licensed or certified personnel identified in the application. The law requires minimum insurance requirements for such personnel, but I understand that I may require more insurance to protect my interests. By executing this form, I acknowledge that I have made inquiry regarding the competence of the licensed or certified personnel and the level of their insurance and am satisfied that my interests are adequately protected. I agree to indemnify, defend, and hold harmless the local government, the local building official, and their building code enforcement personnel from any and all claims arising from my use of these licensed or certified personnel to perform building code inspection services with respect to the building that is the subject of the enclosed permit application. I understand the Building Official retains authority to review plans, make required inspections, and enforce the applicable codes within his or her charge pursuant to the standards established by S.553.791, Florida Statutes. If I make any changes to the listed private providers or the services to be provided by those private providers, I shall, within 1 business day after any change, update this notice to reflect such changes. The building plans review and/or inspection services provided by the private provider is limited to building code compliance and does not include review for fire code, land use environmental or other codes. Page 1 of 2 ^ The following attachments are provided es required: 1. Qualification statements and/or eaumoo of the private provider and all duly authorized representatives 2. Proof ofinsurance for professional and comprehensive liability in the amount of $1 million per uununenup and $2 million in aggregate for any project with a construction cost of $5 million or less and $2 million per occurrence and $4 million is aggregate for any project with a construction cost of over$5million. Individual Corporation ' Partnership Print Corporation N Print Partnership Name By: By-. (signature) _J6ignatbre) (signature) Print Print Print Wenne: Name: Robert Ford Name: Its: Its: Address: Address:Ad@nsss Address-, Po Box 4411wm.Kennesaw,mu 301e0 Telephone Telephone 480'378'1538 Telephone No.: No.. No.. Please use appropriate notary block, STATE OF COUNTY OF ind6/idws| Corporation Partnership � Before me,this ________day of Before me, this Before me,this _______ day of 20__. personally ,2O__.personally appeared appeared of Partner/agent ACmqooratioo, on behalf of the state corporation Apartnorship, who executed the foregoing who oxouuk»d the foregoing who executed the foregoing inotnummnt, and acknowledged inohnmant, and acknowledged instmment, and acknowledged before me that same was before me that name was before ma that same was executed for the purposes executed for the purposes executed for the purposes therein expressed. therein expressed, therein expressed. Personally known v/ or produced identification Type nf identification produced Signature ofNotary Print Name Notary Public:PubUc NOTARY STAMP BELOW &1y commission expires: Page 2cd2 UNIVERSAL ENGINEERING SCIENCES, INC. .`IN9802 Palm River Rd. Tampa, FL 33619 Phone: 813-740-8506 Fax: 813-740-8706 E-mail: TampaBID@UniversalEngineering.com Alternative Inspection Services Agreement Project: PT Solutions—Zephyrhills—7403 Gall Blvd, Zephyrhills FL 33541 Provider Firm: Universal Engineerinq Sciences, Inc. Private Provider Name: Mark K Hardy P. E. Address: 9802 Palm River Road, Tampa, FL 33619 Phone: 813-740-8506 Fax: 813-740-8706 Names, License/Certificate Numbers, and License description of provider and duly authorized agents who will be providing services for this project. Name: License/Certificate No.: License/Certificate Type: Mark Israel 47070 Professional Engineer Mark K Hardy 57233 Professional Engineer George Dixon BN1008 Standard Inspector Daniel Sirois BN6668 Standard Inspector Kenneth Scheitler BN2552 Standard Inspector Jeffrey Waterman BN7133 Standard Inspector Frank Ross BN4330 Standard Inspector Anthony Pino BN2994 Standard Inspector Gregory Yantorno BN3290 Standard Inspector Steve Lee BN5627 Standard Inspector Jon Betcher BN5128 Standard Inspector Rene L. Pepin BN701 Standard Inspector Kevin Eichelberger BN7010 Standard Inspector Robert Bott BN2297 Standard Inspector As the private inspection services provider for this project, I have read and agree to be bound to the provisions of State Statute 553.791. 1 further agree and understand that only the above listed personnel erform inspections on this project and that if for any reason the inspection personnel should chan��)�bw'f �/� �n listed above should discontinue to quality as a duly authorized agent,you will be notified Q ••�., Ii���/' ° Printed name of Alternative Provider: Mark K Hardy, P. E. `vs Signatu of Altgrnalve i er at? State of Florida, County of Hillsborough, ,.�� _ ,� ; �1d'a5��fyPti .jr � • ,�° 'sc p�f� STATE OF o `, �sj•- °° 18Mar rd , who is Sworn to or affirmed and subscribed before t '" '," a of e ° , � �p {b Y ° s • OF�ID O personally known to me. 4�; ao4'; s �i ••.. ..•• Q o "•�b M; ��iii SSI ALONG.., Diane Rivera oF�s2Z74 �11 ,!r► 1�` a��;F�nihtu�•• • Q'� . Printed name of Notary ;C •.•.• °oQvhgn re of Notary Notary Public Stamp: iso1'rAT aO�� `��a COMcheck Software Version 4.0.8.1 Interior Lighting Compliance Certificate L a Project Information Energy Code: ! 2017 Florida Building Code, Energy Conservation Project Title: Project Type: New Construction Construction Site: Owner/Agent: Designer/Contractor. 5, Additional EfficienGji;Package(s) Reduced interior lighting power.Requirements are implicitly enforced within interior lighting allowance calculations. Allowed Interior Lighting Power A B C D Area Category Floor Area Allowed Allowed Watts (ft2) Watts/ft2 (B X C) 1-Gymnasium 2230 0.85 1887 Total Allowed Watts= 1887 Proposed Interior Lighting Power A B C D E Fixture ID: Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt. 1-Gymnasium LED:C:6"SUSPENDED LED CYLINDER:Other. 1 3 8 23 LED:D1:6"RECESSED DOWNLIGHT:Other. 1 13 13 166 LED:D2:6"RECESSED DOWNLIGHT:Other. 1 2 13 26 LED:L:Z LED STRIP:Other: 1 1 21 21 LED:P1:LED LINEAR PENDANT:Other: 1 19 52 988. Total Proposed Watts= 1224 Interior • • • better than code Interior Lighting Compliance Statement Compliance Statement. The proposed interior lighting design represented in this document is consistent with the building plans, specifications,and other calculations submitted with this permit application.The proposed interior lighting systems have been designed to meet the 2017 Florida Building Code, Energy Conservation requirements in COMcheck Version 4.0.8.1 and to comply with any applicable mandatory requirements listed in the Inspection Checklist..` Brian M.Armenta � Ms�t., I `A,.,,,,,;,> >�, 04/00/2018 Name-Title Signature Date FM EVIEHAD FOR 0 0 E C'Q If H A K C E L-23m, M E NCE INC. Project Title: Report date: 04/09/18 Data filename: \\share.peiatl.com\projects\118\118166 PT Solutions Zephyrhills FL\118166 Com.cck Page 1 of 5 COMcheck Software Version 4.0.8.1 Inspection Checklist Energy Code: 2017 Florida Building Code, Energy Conservation Requirements: 100.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by°the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section # Plan Review - Complies? Comments/Assumptions &Req.lD C405.6 Plans,specifications,and/or ;❑Complies Requirement will be met. [PR17]1 calculations provide all.information ;❑Does Not with which compliance can be determined for the electrical systems ❑Not Observable and equipment and document where UNot Applicable , exceptions are claimed. Provisions are made for metering individual tenant units. Feeder connectors(for feeder and branch circuits)sized in accordance with approved plans with maximum drop of 5%voltage drop total. C103.2 Plans,specifications, and/or `❑Complies 'Requirement will be met. [PR4]1 calculations provide all information T]Does Not with which compliance can be determined for the interior lighting ,❑Not Observable and electrical systems and equipment '❑Not Applicable and document where exceptions to .the standard are claimed.Information provided should include interior lighting power calculations,wattage of; bulbs and ballasts,transformers and control devices. C406 Plans,specifications,and/or C❑Complies Requirement will be met. [PR9]1 calculations provide all information ;❑Does Not with which compliance can be .determined for the additional energy ❑Not Observable efficiency package options. ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3. Low Impact(Tier 3) Project Title: Report date: 04/09/18 Data filename: \\share.peiatl.com\projects\118\118166 PT Solutions Zephyrhills FL\118166 Com.cck Page 2 of 5 # Rough-In Electrical.Inspection. Complies? Comments/Assumptions & Req.ID Section , C405.2.1 Lighting controls installed to uniformly ❑Complies Requirement will be met. [EL15]1 reduce the lighting load by at least ;❑Does Not 50%. ;❑Not Observable ❑Not Applicable C405.2.1 Occupancy sensors installed in ;❑Complies :Requirement will be met. [EL18]1 required spaces. :❑Does Not ❑Not Observable ❑Not Applicable C405.2.1, 'Independent lighting controls installed ;❑Complies :Requirement will be met. C405.2.2. 'per approved lighting plans and all ❑Does Not 3 :manual controls readily accessible and; [EL23]2 ;visible to occupants. ❑Not Observable' ❑Not Applicable C405.2.2. Automatic controls to shut off all ;❑Complies 'Requirement will be met. 1 !building lighting installed in all ❑Does Not [EL22]2 buildings. '❑Not Observable' ❑Not Applicable C405.2.3 ;Daylight zones provided with UComplies Requirement will be met. [EL16]2 individual controls that control the ❑Does Not lights independent of general area lighting. ;❑Not Observable, ❑Not Applicable C405.23, Primary sidelighted areas are ;❑Complies .Requirement will be met. C405.23. equipped with required lighting '❑Does Not 1, controls. C405.2.3. ❑Not Observable 2 ❑Not Applicable [EL20]1 C405.2.3, Enclosed spaces with daylight area ;❑Complies 'Exception: Requirement does not apply. C405.2.3. under skylights and rooftop monitors QDoes Not 1, are equipped with required lighting C405.23. controls. �❑Not Observable; 3 UNot Applicable [EL21]1 C405.2.4 Separate lighting control devices for ❑Complies Requirement will be met. [EL4]1 specific uses installed per approved ❑Does Not lighting plans. ❑Not Observable ❑Not Applicable ; C405.2.4 Additional interior lighting power '❑Complies Requirement will be met. [EL8]1 allowed for special functions per the '❑Does Not approved lighting plans and is automatically controlled and ;❑Not Observable separated from general lighting. El Not Applicable C405.3 Exit signs do not exceed 5 watts per ;❑Complies Requirement will be met. [EL6]1 face. :❑Does Not ❑Not Observable' ❑Not Applicable Additional Comments/Assumptions: 11 High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Report date: 04/09/18 Data filename: \\share.peiatl.com\projects\118\118166 PT Solutions Zephyrhills FL\118166 Com.cck Page 3 of 5 C Section # Final Inspection Complies? Comments/Assumptions & Req.ID ,C303:3,, Furnished O&M instructions for ❑Complies :Requirement will be met. C408;2:5..1 systems and equipment to the ;❑Does Not 2' building owner or designated [FI,171.3 representative. ;❑Not Observable ❑Not Applicable C405.4.1 Interior installed lamp and fixture ❑Complies See the Interior Lighting fixture schedule for values. [FI18]1 lighting power is consistent with what ❑Does Not is shown on the approved lighting plans,demonstrating proposed watts :❑Not Observable are less than or equal to allowed ;❑Not Applicable watts. C408'.2:5 's Furnished as-built drawings for ElComplies Requirement will be met. electric power systems within 90 days ;❑Does Not of system acceptance. ❑Not Observable, ❑Not Applicable C408.3 Lighting systems have been tested to ;❑Complies Requirement will be met. [FI3311 ensure proper calibration,adjustment, '❑Does Not programming,and operation. '❑Not Observable ❑Not Applicable Additional Comments/Assumptions: 1 I High Impact(Tier 1) 2 1 Medium Impact(Tier 2) 3 1 Low Impact(Tier 3) Project Title: Report date: 04/09/18 Data filename: \\share.peiatl.com\projects\118\118166 PT Solutions Zephyrhills FL\118166 Com.cck Page 4 of 5 2018107934 Permit No. Parcel ID No 3q-2-5-2 I—O ooC) 00600 v-C7o2Z ,/[/ NOTICE OF COMMENCEMENT Slate of F1Ori�� County of $ (� THE UNDERSIGNED hereby gives notice that Improvement will be made to certain real property,and in accordance with Chapter 713,Florida Statutes, the following Information is provided in this Notice of COMMen nt 1. Description of Property: Parcel Identification No. i C.. Street Address: (l 1 vet k r l 1q, F 5* 1 Z General Description of Improvement TQJVLQ.f1 t h u i'l nut Z r.C4 a rl'�' ern/S�i 3. Owner Information or Lessee Information if the Lessee contracted for the improvement: ,IIn I^ire-!,2"ig Py-,UU -it N,0o A'li�a Q Address City Slate Interest In Property. Name of Fee Simple Titleholder: (if different from Owner listed above) Address City State 4. Contractor.-Ags � nt S,Irr.. Name Address //�� ((�� City State Contractor's Telephone No.: SIS. OClg-1. .9-BoR S. Surety: !" Name R pt:1969105 Ree: 10.00 Address city DS: 0.00 IT: 0.00 AmountofBon`d: $ Telephor 06/26/2018 K. R. , Dpty Clerk 8. Lender. N 1Q PRLIL�I L,Ph.D.PASCO CLERK 6 COMPTROLLEI, Name 06/26/2018 03:43 m 1 of 1 Address city OR BK ,�� Ps 2300 Lenders Telephone No.: 7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by Section 713.1 (1)(a)(),Florida Statutes: Name OQf Address city Slate Telephone Number of Designated Person: , 8, In addition to himself,the owner designates 9T Snku,S �©n$ of to receive a copy of the Lienors Notice asprovided in Section 713.13(1)(b),Florida Statutes, Telephone Number of Person or Entity Designated by Owner: IUD- 10 I!j • L"7 g 3 S 9. Expiration date of Notice of Commencement(the expiration date may not be before the completion of construction and final payment to the contractor,but will be one year from the date of recording unless a different date is specked): MIA WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalty of perjury,)declare that I have read the foregoing notice of commencement and th the facts stated therein are true to the best of my knowledge and belief. STATE OF FLORIDA COUNTY OF PASCO Signature of Owner or L20ce,or Owners or Lessee's Authorized Officer/Director/PEA aneger Signatory's Titie/offi� The foregoing Instrument was acknowledged before me this A day of JJtN� 20 L by �J as C FO (type of authority,e.g.,officer,trustee,attorney in fact)for D V�s Notary (name of p�half of om insWG�executed). Personally Know Produced Identification❑ Note Signature l= CltA(�r C p Type of Identification Produced w Name(Punt) 7 `(�li C„u « �G OTA�C�r i p(MEES AuB wpdata/b cs/noticecommen cemen;_pc053048 ;813 251 3288 # 1/ 1 07-13-18;01 ;58PM;JA GREEN 0711312018 1'1t06 #363 P.001 . 1r ro rrif ate�a4.fuao Clty of Zsoyftls Pelmh Application Fax tit3.78a4421. swida>po" mem hata Reaawad t 1= �v Comud tar Potffwno 4 � rrelrttl rail Own ara Ner►ua f ' WO Oaaae libWo okod ar 0~&Addm# $ xK t Dt OwaVPhon.umaior �&lesplatttiohotderieetl� c��a_,_____,__ �_ CirrnrPA6naNumlur 1 ,.,�,^,1 FgaBtmptoTnlafwtderAddrap �osADOReSs uk- 76tors ;ays:anRsrctN � �� PARCR4ttty -�.S-2t -��� (Oe7yMSD1'11gY PaolktrtYTlutNQSiCtf . WORKPI'lom D N W=MRQ AOD&r W SiC+N DE�{OLISFi INSTALL !J m PROPOSED UM = SFR C3 COMM OTHER TYFEOP CONSfiUJC110N C3 BLOM p FRAM p SsEal. � �" """'"'•"—" i + east D1!SCR1P1roN CIF woRK BUfs,OINOSttIC �50POO7AGE� lllll ' ..�. S+Af D1Nt3 S t C 4, '�� VALUATION OF TOTAL OONSTAMMON j ECI cTR+Ca s AMP 61UMCE PROGIMSS Emay W,it.m pqo .,._... cii macHANICAi. $ � VALIDATION OF MSCiAMOAt INSTALLATION d ROOFING t SPEctAt tv co or," FIN11"h D FLOOR ELEVATIONS FLOO6 ZONSAPTA =YES NO — ou: R COn1PANY ---��r - C�lk( kC11QC I sititrzalURS wmatUteQ ceeauR7Cet'� iw�,f" Mom 1OMPANY .�..�`� +• ,.,, �/ ,r/„$1�NA7�f1E t lS7EA1 �Y'lV, mzcuV� YI'N�'-+��•�--�•��•1{" 17 +4<LX Aetdrvea �^U,oen�iP — I } PLLFtlSSR �. t COAP/ViY � lGc"N+ } '�+" 81GNAYUNE 1�e�areaRO / PP.Rcmak ' YIN Addr�p �y Llrpw• i� ✓ �+" MSCHAKMAt. Ir"OMP 1V �+•fr(t�i� /✓v!, $10NAT{SiE .�• FOPMEtt� 1 gEounrjta I YIML I � Adttf o JL• .�* LDCaMa 9 go OTHER COMPAiHY 910NA7UflH AEG1wraR8D I YIR lRt:oux"N I Y I N Addraea Lioena4lt RUCENT1A1. Aloo(2)Pas Plana:(2)sofa or auldim Pkos,(1)set or Mwo Roma,Refit FmA for now o maW dtoe, alnafrmanlenN4)wexklno�sener,ugminatrfetr.gwSGredcnslta.Conrtn,aslgnPterrr,SlonmxatarPiarntidSlRFalcointWlad, Sanitz=211,M dwpataf;Sltn Walk permit for subdtuel�■Aetpe pr4JeW COMMMCIAL AftarA(2)cwnptas•eats of Bu une t ins Plue a trio Setey Pape:it)sat 4t E+tagfy forme.k•G W Pmmftror nwroan.due4m. M�mu+ratan(tWwruiAnQdnyaaRerw>mtuotdata Ragowwwle.com"WonPleru,Stomvalsfp1mnw 6%Paw imww, Sw*wy Fadsdea a t dcmpaw.We Work Pam*feted naw Proye W A114wawrcW r ig0em m mnst moal a(np Lvm SKIT(Pmrj.. AttM($)aala of Enpineem Pknr. '""'PROPERTY SURVEY requtrerl toraff NEW tronspLuslkn. ee■■e ■■■tee_rs .■e�r■se.aseAllr.}root,OlJ•`t+stLLtiSA.1, I-111 tII111111A •ear■� -t3ifetntppa; . F3fi otd oppitratioQ oompielafy. Cr,nnvraContradoraioafredt at eppi6raden.notruf>xd . p aYer;2SaG,a riaStti of Conunaoeaanant 4 raqukad. tA1G aparadoe QYar i!'dG� A4gM(for the co*vclol)erpaw dlAWmq((*rftwrm)WwWbesomoonavttrinotartssadNneriramwmerautnefirJnyam" OV07MCCOiiN11RPERMMING - (64y41C6ftWfeQUtad) Romfetfahifto" sovom SenkaUWadee alai Fantae(P(41/SreraylFb*W) cri+nwmy"ol amcoomor non pubu toodweya.,+aeae now n" City of Ze hyrhills , ~, Uniform Notice of a Low_ tage Alarm System Project Owner's/CustomerName f Sp tt. #2 I Address� / Y V city 1t S St �G zip 33,5 Phone E-mail Contractor YUt t Lic.# &1 Zpp(33Z Address 6 City W S Zip �34(o r Phone ``* DateProjectComplete 2 Scope of Work. S € l Signature: Owner or tenant or contractor or authorized representative Notice is hereby given that a low-voltage alarm system project has been completed at the address specified above.I certify that all of the foregoing information is true and accurate. 10111,3 section 553.793 FS L t D,L•SIGN-BUILD OUTS;IDC' PW4T INSIDE TWIT DATA CGNT,ERS WTRULESS U, I 616 Warn;Bond&ard Tampa,FL 33619 Pho4 813440-2300 Fig:813-740.0158 IN USiRUCTUR Date: August31, 2011.8 Project: City.of Zephyrhilis Permit Authorizations for ES12001338 I, Rooprt:E: Keliy:give Authorization to the foilowing KCI.employee to use my-State Low Voltage license:#ESA20.0,13381o,summit and,receive permit"$:with'the City of Zephyrh,ills Roger Jewell 352-573-8446 Diver license#J.400-724-64=29:0-0 License Holder: Notarized by: 181 R;ORTON ;r� +�:=; Notary'Publk:-S4i'§l`fl72 , .•_ Commloelaq A�FF 937472 =?,, Comm Expiies Mar 11,2020 ••'^°�n�"`�� t3ondsd through Rietialal Ndtary.Assn. W%v WnXCICONNE.C7S..COM RICO eCfiS • t1,�AIAA - "V City of Zephyrhills BUILDING PLAN REVIEW COMMENTS 4 Contractor/Homeowner: /1d� lJ r c Date Received: Site: g-56443,� Permit Type: �1 Approved w/no comments- Approved w/the below comments: ❑ Denied w/the below comments: ❑ This comment sheet shall be kept with the permit and/or plans. �"70 Kalvin Switzer 41ans Examiner Date Contractor and/or Homeowner (Required when comments are present) 813-780-0020 City of Zephyrhills Permit Application Fax-813-780-0021 Building Department Date Received z3o-t-6 Phone Contact for Permitting 727-243-8933 Owner's Name Preston Bolt (Zephyrhills Merchant Square LLC) Owner Phone Number N/A Owner's Address 800 Highland Ave Ste 200 Orlando, FL 32803-3907 Owner Phone Number N/A Fee Simple Titleholder Name N/A Owner Phone Number N/A Fee Simple Titleholder Address N/A JOB ADDRESS 7403 Gall Blvd LOT# SUBDIVISION PARCEL ID# 34-25-21-0000-00300-0020 (OBTAINED FROM PROPERTY TAX NOTICE) WORK PROPOSED El INSTALL CONSTR® ADD/ALT 0 SIGN ® = DEMOLISH INSTALL REPAIR PROPOSED USE SFR = COMM = OTHER TYPE OF CONSTRUCTION = BLOCK = FRAME = STEEL = DESCRIPTION OF WORK Installing One 43sff Electric/Illuminated wall sign BUILDING SIZE 29 Ift SQ FOOTAGE 2,320 sff HEIGHT 25 ff ®BUILDING $ 2000.00 VALUATION OF TOTAL CONSTRUCTION ®ELECTRICAL $ 350,00 AMP SERVICE = PROGRESS ENERGY = W.R.E.C. =PLUMBING $ `��2-1 l $ t MECHANICAL VALUATION OF MECHANICAL INSTALLATION Z =GAS = ROOFING = SPECIALTY = OTHER / FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO V S► ' BUILDER r '��� COMPANY Anclote Sign corporation SIGNATURE REGISTERED Y/ N FEE CURRENT Y/N Address Lt L I G�S m License# ES-0000373 ELECTRICIANvcdr�A � PANY I Anclote Sign corporation ,, SIGNATURE REGISTERED Y/ N FEE CURRENT I Y/N Address 716 Live Oak street Tarpon Springs, FL 34689 License# ES-0000373 PLUMBER COMPANY SIGNATURE REGISTERED Y/ N FEE CURRENT Y/N Address License# MECHANICAL COMPANY SIGNATURE REGISTERED Y/ N FEE CURRENT Address License# OTHER COMPANY PatrickA AG SIGNATURE REGISTERED Y/ N FE�CURREIN�ffTY/N Address l ` TflA1 5 License# 0373 • ■ • • ■ • • ■ • • ■ • • ■ • • 1 • • ■ • • ■ • • ■ • • ■ • 1 ■ ■ ■ • • 1 ■ • ■ . ■ ■ ■ ■ • ■ ■ • ■ ■ ■ RESIDENTIAL Attach(2)Plot Plans;(2)sets of Building Plans;(1)set of Energy Forms;R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster,Site Work Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page;(1)set of Energy Forms.R-O-W Permit for new construction. Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. ""PROPERTY SURVEY required for all NEW construction. I I I I I I I I I I I I I I I I I I I I I I I I t 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 t t 1 1 1 1 1 1 1 1 1 1 1 1 Directions. Fill out application completely. Owner&Contractor sign back of application,notarized if over$2500,a Notice of Commencement Is required. (A/C upgrades over$7500) Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) Reroofs if shingles Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is$2,500.00 or more, I certify that I,,the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner" prior to commencement. CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six(6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90)consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. FLORIDA JURAT(F.S.117.03) OWNER OR AGENT CONTRACTOACtl Q, 0',", Subscribed and swom to(or affirmed)before me this Subscribed and sworn to for affir ed)befor this by 5 3 0-16 by J t (z So a Who is/are personally known to me or has/have produced Who's/ re perso ally known to me or has/have oduced as identification. F1( �}psarn as identification. Notary Public o,/Lu Notary Public Commission No. Co �mi ion N . „r r, Name of Notary typed,printed or stamped Name of No ri omm ssion FF 150422 o� Expires December 12,2018 ''•F gc�tQ` Bonded Thru Troy Faln Insurance 800J85.701 B ZEPHYRHILLS MERCHANT SQUARE, LLC City of Zephyrhills, FL Date: v '1'lc RE: PT Solutions 7403 Gall-Blvd Zephyrhills,FL 33541 Merchants Square To Whom It May Concern: I, of the property at the above referenced address, do hereby authorize Anclote Signs-to obtain a permit for and to install sign a above referenced property. Signature Date Notarized: STATE OF FLORIDA The foregoing instrument was signed before me this 10h day of hA 2018 by P(esron 501+ ,property owner. - Aaha I r► .��� Notary Public NEE c State of Florida McGlown �d( L_ sion GG 186391 y312022 (Print Name) MEDICAL ARTS COURT m CA � -0 w m ® 1v 11 If11:411 11#1111`1VI t E°l It � I '�I = D ill T!{ { - - s Na f• -rlr ,{{yl �l.,Ili 17_ ± _—. _ "p- ,="•'�„� '�Y �' r v {°1 Ei i�1 1 r Wjp.§�, f.3T_) PI;E3"a1�'T1 l;11I{'li'1 j'`f t r cn m 1 r f 1: 0 D. Q V C I r O m . x. _ ;t.l{ .a n cow7 ; r t m O ~� { f�ty - ' l - -- ca W. :=r -- ��*!�E•��Yt t'!�fi�b?>Z{'s�ts{Ise�f �_�'-': -, xTt ft PRETTY POND ROAD �' -j � xt S�- ,�� '�:"��„r _ n- Sv"..x;ayr``tea c -�!`-r _ -ya-�+�F !•- t^,�• - �- ,. '.c, 'mot °r^°yP�r 4, , w � -7-'��'�•.�� �..,. .:-„ter-,;:�=;:,-..• �' �� „� { �v a , `=, +ts-�- .w '4 s �� � •,te .cuss.. �:. _ 3 ZZ 1: �..+. .. Yam= "+""''"' - _- _ +r- _ —"' '"--• �, 1 , - H i ---------------- _•�`g' -+cry-" EAST ELEVATION M WOW. _ 29 LFT - J i'. IftPTI SOLLI 6NS f .. . 172" 37" 132" lop coSOLUTION co C�i`.�;"''`��i;'-'!�'� n �?It r, l;�?;� �.t ram,',•. { I — r / i J�iY3 V 1: •-a 'N L u u I .,i `'oI'Y;)v ii: 91" 96" REVIE DAT �` CITY OF ZEPHYRHILLS Letters w� 43 SgP+AN EXAMINER Cl ��. th 17, Sign Height 36" Sign Depth 9" Letter Length 31" Letter Height 37" Letter Depth 4" Can Length 96" " Can Height 11" Can Depth 4" ELECTRIC Raceway Length 168" SIGN Raceway Height 10" LISTED Raceway Depth 5" _ No AB123466 LED WITH PREVAILING LIED Channel Letter-Raceway Mount Ac li TYPICAL-Not To Scale-X Used as Sample Pewell CODE, e NATIONAL ELECTRIC CODE, AND THE CITY OF ZEPHYRHILLS AndOte Sign Corp Customer:PT Solutions Sign Type:Illuminated raceway mounted Date Drawn:522-18 Drawing#2272 shoptelev ((�� pPl■ �/T 716 Live Oak St 7403 GaII Blvd wall sign .S■ Tarpon Springs,Fl 34689 zephyrhills,FL Office:727 243-8933 Total Sign Area:43 sft SCALE:NTs .gin F �aW l.Si C State Lic:ES0000373 , so com auo ow LED ILLUMINATE D ��,.•�CENW is s••G ry 172" = No.67382 ° 37" 1'32" _ B • STATE o *' O •. A, _ R VD. E ;"WM — S• •• ATU J WL ,. C O.5 FP S CICA to=0 O 91 G 4C 96�� =gym I �/ LL �C� . •O..M Nm lL C iA ¢ .. C 0^ N on TYPICAL RACEWAY MOUNT LED CHANNEL LETTER WITH TAG LINE � NOT TO SCALE-A-USED AS SAMPLE ANCHOR SCHEDULE ••ALL FASTENERS SHALL BlNCRAL SDlOIFZCATlONS BE SPACED EVENLY" QTY or _ Le—si oN RAQw rs. FABRICATED-NUM RETIRNS,FLAT ACRYLSC FACES vVIT I-TRIMCAP FACE RETAINERS. WALL MATERIAL ANCHOR TYPE SPACING ,rB UL IUVMI mD'nG BY IEDR vIIA WITM I EVOt.TmS O SUPPIIPS WITHIN RACflNAYS. RACEWAYSLLUM EDON BUILDIN REDID 1/4"THREADED RODS WITH MIN PAIRS AT e±±a rc 2"EMBED IN ADHESIVE 26"O.C. WAL •� a CONCRETE(3ksi)or. 1/4"'TAPCONS(OR EQUIV)WITH PAIRS AT MIN(4)#10 SMS PER 'O HOLLOW MASONRY 1'J5";EMBED 35"O.C. LETrER TO RACEWAY o 1/4"EXPANSION ANCHORS WITH PAIRS AT °a a c 15"EMBED 40"O.C: IR Iv G in N m '1/4':1TOGGLE BOLTS PAIRS AT oBoanacrsw^cx a 1/2"PLYWOOD 30"O.C. m +�''' E v LA (NO ACCESS BEHIND) 1/4"WOOD SCREWS OR PAIRS AT u°°•°^ ^°°�• ELECTRICAL REQUIREMENT N 9 TAPCONS,FULL EMBED 20"O.C. — LEDS white 3 % POWER SUPPL 2 METAL STUDS OR #14'METAL SCREWS TO MIN 18ga PAIRS AT AMPS 3.75 w METAL PANELS ST OR 0.096"ALUM 27"'O.C. I CIRCUITS 1 2OA-120V E n EEL Q DISCONNECT 1(1)20A-120V s HOLLOW WALL 1/4".THRUBOLTS OR LAGS TO PAIRS AT mm (BLOCKING BEHIND) SOLID BLOCKING BEHIND 71 48"0•C. *ALL ELECIRICAL COMPONENTS SHALL BEU.LLISTED Iloo all *SIGN SHALL BE GROUNDED PER N.E.G ARTICLE 250 r v u ti u:cmrc Z c IB in cz °>V Ogg Customer:PT Solutions Date Drawn:5-22=19 Drawing 2272 Eng °aN AnClote Sign Corp . Sign Type:Led illumiliated nN mounted r o 7403 Gall Blvd Channel letters o CLF S EE 716 Live Oak st Zephyrhills,FL 33541 E Tarpon Springs,Fl 34689 o" Office:.727 243-8933. SCALE:NTS This Drawing Is The Property OfAndote Sign CjFor COR ION State Lic:ES0000373 Total Sign Area :43 sft McRto e S go We Use Fortion epr datfion;ke Res General -Designl elect al"�cont�ctoh No etectrlwlrev ewhas•BIn9CAcinMarid no pert fiCat of in SuchSsdlntendedh StNQural Hurricane Zone meetsfrre�eqquZements ofAlC131&14 AV 36010 ADM115&INDS15,as ahao cable�Stec"el��"^eat^s shall be coc"at d"[Ilan oilothe wecifi mtected aBal�st co oilon drFBC Sec 3a2t/iZoZnZs2a.6 provided Alroum cam anenh the n co^taR w�h steel NO[es:or embedded In concrete shalibepalntedorproteRed as pre�scdbed lnADM1-15(la),orplasUUneopmmspacersprovlded.•Al9exposedfasteners shall beSS.or have a protective coating for corrosion Prosedctlon.•All welding sohall beper AWS requlremen't�5leel welds i70wc electrodes•Aluminum weWs:4043 fiileralloy.•Alum ex[ruslons"6063 Te orstrorger,UN.O. .,11111••. EasySeats easyseals.com DESIGN CALCULATIONS FOR ITT SOLUTIONS _ WAL- L-.M-OUNTED-SIGNS=_= - 7403 Gall.Blvd—Zephyhills GENERAL NOTES: 1. Design is in accordance with the Florida Building Code 6th Edition(2017) for use within and outside the High Velocity Hurricane Zone-(HVHZ). -- 2.----Wind loads-have=been-calculated per the-requirements of ASCE 7-10 as shown herein. 3. These engineering calculations pertain only to the structural-integrity of those systems,components,and/or other construction explicitly specified herein and/or in accompanying engineering drawings. The Index: existing host structure(if any)is assumed to be in good condition, Pg 1 Cover capable of supporting the loaded system,subject to building department Pg 2 Wind Loads approval.No warranty,=either expressed or implied,is contained herein. Pg 3 Anchor Design 4. System components shall be--as noted_herein:.-All--reference-s"to named - components-and:installation-shall-conform--to=ma nufacturer's-or-industry- specifications-as-summarized_herein..._ 5. Where site conditionsA- eviate-from=those noted-herein,-revisions may-be y Engi r `%4 seal:valid -required-or-.a-separate--site=specific-engineering:evaluation-performed-_- M§lt ��S6. Aluminum-components-in-contact-with-steel-or-embedded-in-concrete ' -- _F •• -= shall-be-protecte-d as-prescribed=in-the 2015=A luminum=Design-Man ual,--- N--�&3 - --components .ontactwith-butn -concretePart-L.-Steelshall-be coated,-painted;or-otherwise-protected against-corrosion. 'P 7.._ Engineer seal-affixed-liereto_validates structural-design-as-shown only. O Use of this-specification-by-contractor,-et.Al,=indemnifesand-saves-- =- -- - harmless this engineer for all costs&damages including legal fees& �� �, #67382 apellate fees resulting from deviation from this design. Easy Si4f ittlatt6iff Auth#31124 N Federal Hwy,#200 Ear Seals.com Page 1 Bocaoca Raton,FL 33432 —1 FasySeals CALCULATIONS FOR WALL-MOUNTED SIGNS e&Vsealsmm ASCE 7-10 Design Wind Loads WALL-MOUNTED SIGNS Building Specs V=1 -170 mph ;Basic wind speed ASD Load Combo Coeff:' 0:6 Exposure:___ -C.; . ' Calculations a= 9.5 3-sec gust speed power law exponent Kd= 0.85 Directionality factor zg= 900' Nominal ht.of atmos.boundary layer Kzt= 1:0 Topographic factor Gcpi= 0_.__ - Internal pressure coeff A= 10 sq ft Tributary area 170 mph - UP "C" WALL-MOUNTED SIGNS ASD WIND-PRESSURES SIGN CENTER" 'CORNER II Q a HEIGHT (Zone 4)" :- (Zone 5)- Y Y q= ,,, ft _ _35.2_psf=:; =44.8 psf_ _ =_-0.85 53.4 -1.10 -1.40 20 ft 37.4 psf ; 47.6 psf 0.90 56.7 -1.10 -1.40 25 ft 39.2 psf 49.9 psf 0.95 59.4 -1.10 -1.40 30 ft 40.8 psf 51.9 psf 0.98 61.8 -1.10 -1.40 35 ft 42.1 psf 53.6 psf 1.01 63.8 -1.10 -1.40 40"ft 43.3 psf 55.1 psf 1.04 65.6 -1.10 -1.40 45 ft _44.4 psf- 56.5 psf 1.07 67.3 -1.10 -1.40 _ 50 ft 45.4 psf ; 57.8 psf 1.09 68.8 -1.10 -1.40 - 55 ft- 46.3 psf 58.9 psf 1.12 70.2 -1.10 -1.40 ."60 ft. 47.2 psf 60.0 psf 1.14 71.5 -1.10 -1.40 70 ft .. 39.9 psf 79.7 psf 1.17 73.8 -0.90 -1.80 86 ft 41.0 psf 82.0 psf 1.21 75.9 -0.90 -1.80 90 ft 42.0 psf 84.1 psf 1.24 77.8 -0.90 -1.80 100 ft--; __43.0 psf ; . 86.0 psf 1.27 79.6 -0.90 -1.80 110 ft= .-43:8-psf - ---87.-7 psf 1:29 81.2 -0.90 -1.80 120 ft 44.7 psf 89.3 psf 1.32 82.7 -0.90 -1.80 130 ft - :--45.4 psf 90.8 psf-- 1.34 84.1 -0.90 -1.80 _ 140 ft= = _-46-.1 psf- = 92:3 psf = -1.36 85.4 -0.90 -1.80 150 ft..-. 46:8 psf _:93:6 psf - .,-. 1.38 86.7 -0.90 -1.80 175-ft-- 48.4 psf--;. 96.7 psf . 1.-42 89.5 -0.90 -1.80 200 ft _, :-.40 psf -99:5 psf- =1.46 92.1 -0.90 4.80 250-ft- :52A psf, 104:2 psf- 1.53 96.5 -0.90 -1.80 Page 2 Easyseais CALCULATIONS FOR WALL-MOUNTED SIGNS easysmkmm Wall Sign Anchor Design Structure Dimensions & Loading Design wind pressure: P= 51.9_v psf Sign type: Raceway Sign.size:. - h=;- -:31.0..-inches (height) Wall material: Masonry (ASTM C90,1,500 psi min) Anchor type/size: 1/4'1 Tapcon Ref: ITW Tapcon, NOA 07-1126.10 Min Embedment::�1.25" - -- Min edge dist: 2.5" Anchor tensile capacity: Tcap= 195.0 lb (per anchor) _- Check Anchors for Pullout Total Reaction: Rt= 134 lb/ft ...=P*h (along raceway) Anchor spacing req'd s= 34.9 in O.C. ...=(2*cap)/Rt Pairs of anchors at 35 inches on-center(max) 2.9 feet-on center-- - OK,typical.anchor option shown. Ref-anchor schedule for other anchor-options: Page 3