Loading...
HomeMy WebLinkAbout18-19930 CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 19930 FIRE SPRINKLER SYSTEM PERMIT PERMIT INFORMATION LOCATION INFORMATION. Permit Number: 19930 Address: 7920 GALL BLVD Permit Type: FIRE SPRINKLER SYSTEM ZEPHYRHILLS, FL. Class of Work: FIRE-SPRINKLER SYS Township: Range: Book: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Square Feet: Subdivision: ZEPHYR COMMONS Est. Value: Parcel Number: 35-25-21-0130-0000-0140 Improv. Cost: OWNER INFORMATION Date Issued: 7/17/2018 Name: SF ZEPHYR COMMONS LP Total Fees: 145.00 Address: 2851 JOHN ST STE 1 Amount Paid: 145.0.0 MARKHAM, ON. L3R 5R7 CANADA Date Paid: 7/17/2018 Phone: Work Desc: ADD/ RELOCATE SPRINKLER HEAD-HUMANA CONTRACTORS APPLICATION FEES UNIVERSAL FIRES STEMS I C FIRE SPRINKLER SYS 50.00 FIRE PLAN REVIEW FEES 50.00 FIRE INSPECTION FEES 45.00 /C r FIRE-PRESSURE TEST Ins ections Required FIRE ACCEPTANCE Final Chapter 633, Florida Statutes,authorizes the City to charge and collect user fees to pay for the costs of fire prevention and protection related activities such as inspections, plan review,administrative fees,and other costs related to the aforementioned. Complete Plans, Specifications and Fee Must Accompany Application. Commencement of work without written approval of the Fire Department's Fire Marshal or required permits or opening up for commercial activity without an approved final inspection shall be charged double permit fee per day of operation or a minimum of$100.00, whichever is greater. All work shall be performed in accordance with City Codes and Ordinances. "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENgjMENT." CONTRACTOR SIGNATURE PERMIT OFFICE PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTION CALL FOR INSPECTION - 8 HOURS NOTICE REQUIRED ZEPHYRHILLS FIRE RESCUE DEPT- 813-780-0041 O� o „[lAA1DA• City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: Date Received: Site: Permit Type: Approved Who comments:r/ Approved w/the below comments: ❑ Denied w/the below comments: ❑ z51� This comment sheet shall be kept with the permit and/or plans. r G 18'• re Gene Brown—Fire Safety Officer Date Contractor and/or Homeowner (Required when comments are present) 813-780-0020 City of Zephyrhills Fire Fax-813-780-0021 Permit Application Date Received �2 Phone Contact for Permit �L3 _:..�...._,._,_,......<—•:�.__...ri_�...�-___-me,µ. ....zr�-..___.__.��_...._,.......,�__.�_...__.,.,. _._..__� .-.M,..< ....�,....... - Owners N2me lb�lCl Urn �,1a�r1[Q�C Owner's Phone Number V� Owner's Address 600 LJt:>u t,S V[We Fee Simple Titleholder Name Titleholder Phone Number Fee Simple Titleholder Address ��_:�.._.e���.,�::.._/:.__�..._�.-ram... Job Address //"1Z� -C(.�� -bkvd- 2-� 6 �ra;l` �5 ��, j54� Lot# Sub Division Parcel# Bio-Hazard Waste Storage-ANNUAL Fumigation Tent Comm Exhaust Kitchen Hood/Duct Hazardous Material(Tier II or RQ Facility)ANNUAL Controlled Burn Hood Installation Emergency Generator<30 kw LP/Natural Gas-Installation Emergency Generator>30 kw LP/Natural Gas-ANNUAL Sale Fire Protection Maintenance-ANNUAL Places of Assembly-ANNUAL try emi r77q ter Sprinkler ❑ ❑ ❑ Recreational Burn Fire Alarm ❑ ❑ ❑ 0 Sparklers Q Q Hood Cleaning ❑ ❑ ❑ F;�] Sprinkler System Installations ` Hood Suppression El ❑ ❑ ❑ = Standpipes(Sprinkler Sys) Fire Alarm Installation Torch Roofing/Tar Kettle Fire Pumps Waste Tire Storage ANNUAL Fire Works Flammable Application-ANNUAL Valuation of Project Fuel Tanks Other: [Ck GwkC,[ aY— [rep P_ t- t &oCLVI Contractor Company UyLkveT �e S w-s Signature Registered Registered N I Fee Current I Y/N Address 1 -3 4- W!i _ License# c S Cj oo 1 Kai Z ELECTRICIAN Company Signature Registered Y/N Fee Current Y/N Address License# PLUMBER Company Signature Registered Y/N Fee Current Y/N Address License# MECHANICAL Company Signature Registered Y/N Fee Current Address License# OTHER Company Signature Registered Y/N Fee Current Address License# - _ t Directions: Fill out application completely. Owner&Contractor sign back of application,notarized(Or,copy of signed contract with owner) If over$2500,a Notice of Commencement is required(Mechanical work over$5000) Supply two(2)sets of drawings with applicable documentation Allow 10-14 days for review after submittal date. Parcel#-obtained from Property Tax Notice(hftp://appraiser.pascogov.com) NOTICE OF DEED RESTRICTIONS: The undersigned understands that this permit may be subject to"deed" restrictions" which may be more restrictive than County regulations. The undersigned assumes responsibility for compliance with any applicable,deed restrictions. UNLICENSED CONTRACTORS AND CONTRACTOR RESPONSIBILITIES: If the owner has hired a contractor or contractors to undertake work, they may be required to be licensed in accordance with state and local regulations. If the contractor is not licensed as required by law, both the owner and contractor may be cited for a misdemeanor violation under state law. If the owner or intended contractor are uncertain as to what licensing requirements may apply for the intended work, they are advised to contact the Pasco County Building Inspection Division—Licensing Section at 727-847- 8009. Furthermore, if the owner has hired a contractor or contractors, he is advised to have the contractor(s) sign portions of the "contractor Block" of this application for which they will be responsible. If you, as the owner sign as the contractor, that may be an indication that he is not properly licensed and is not entitled to permitting privileges in Pasco County. CONSTRUCTION LIEN LAW(Chapter 713, Florida Statutes, as amended): If valuation of work is $2,500.00 or more, I certify that I, the applicant, have been provided with a copy of the "Florida Construction Lien Law—Homeowner's Protection Guide" prepared by the Florida Department of Agriculture and Consumer Affairs. If the applicant is someone other than the"owner", I certify that I have obtained a copy of the above described document and promise in good faith to deliver it to the"owner" prior to commencement. - CONTRACTOR'S/OWNER'S AFFIDAVIT: I certify that all the information in this application is accurate and that all work will be done in compliance with all applicable laws regulating construction, zoning and land development. Application is hereby made to obtain a permit to do work and installation as indicated. I certify that no work or installation has commenced prior to issuance of a permit and that all work will be performed to meet standards of all laws regulating construction, County and City codes, zoning regulations, and land development regulations in the jurisdiction. I also certify that I understand that the regulations of other government agencies may apply to the intended work, and that it is my responsibility to identify what actions I must take to be in compliance. If I am the AGENT FOR THE OWNER, I promise in good faith to inform the owner of the permitting conditions set forth in this affidavit prior to commencing construction. I understand that a separate permit may be required for electrical work, plumbing, signs, wells, pools, air conditioning, gas, or other installations not specifically included in the application. A permit issued shall be construed to be a license to proceed with the work and not as authority to violate, cancel, alter, or set aside any provisions of the technical codes, nor shall issuance of a permit prevent the Building Official from thereafter requiring a correction of errors in plans, construction or violations of any codes. Every permit issued shall become invalid unless the work authorized by such permit is commenced within six months of permit issuance, or if work authorized by the permit is suspended or abandoned for a period of six (6) months after the time the work is commenced. An extension may be requested, in writing, from the Building Official for a period not to exceed ninety (90) days and will demonstrate justifiable cause for the extension. If work ceases for ninety(90) consecutive days, the job is considered abandoned. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. FLORIDA JURAT(F.S. 117.03) OWNER OR AGENT CONTRACTOR )1, V e:o,5Gtl ►re ��/ S-�P_✓Ll S, k7 Subscribed and sworn to(or affirmed)before me this S}bscribed and sworn to(or affirmed)befoorr Jae this by (D Z! I by J�' ����i' -k�f9C�,fr ,� Who is/are personally known to me or has/have produced Who is/are personally known to me or has/have produced as identification. as identification. Notary Public Notary Public Commission No. Comm ion No. _:a°i !rrue JIANET DIGFOR610 Name of Notary typed,printed or stamped Name of Notary typed,p i gta 6-OMMISSION#GG078277 '9Gp , EXPIRES March 01,2021 ZEPHYRHILLS FIRE DEPARTMENT 38410 6th Ave Zephyrhills, FL 33542 FIRE SERVICE USER FEES increase 1/1/2018 Occupancy No.: Plan No.: I I Contractor: Business Name: Billing Address: Business Address: 120 Business Phone No.: Billing Phone No.: Business Fax No.: Billing Fax No.: Contact: Contact: PLAN REVIEW FEES INSPECTION FEES PERMIT FEE Annual- Education,healthcare,De tentionBCorrectional Public Assembly,Business, schools, Storage,Mercantile and Churches ;Site Plan N/C Industrial. no charge Sprinkler $50 !Multi-Family/Commercial .03 sf up to 800 sq ft $ 24.00 Standpipes $50 !(Minimum Charge$24.00 801 -1,500 sq ft $ 34.52 Fire Pump $50 n'Plan Revisions DBL 1,501 -2,500 sq ft $ 60.02 Hoods $50 2,501-3,500 sq ft $ 90.02 Fire Alarm $50 SPRINKLER SYSTEMS 3,501-5,000 sq ft $ 127.52 LP Gas $50 0-25 Heads $50 5,501-7,500 sq ft' $ 187.52 Natural Gas $50 26 plus Heads $100 7,501-10,000 sq ft $ 262.52 Fuel Tanks- pertank $50 STANDPIPE SYSTEM 10,001-15,000 sq ft $ 375.02 Sparklers $100 Per Riser $50 15,001-20,000 sq ft $ 525.02 Fire Works $500 FIRE PUMP 20,001-30,000 sq ft $ 750.02 Camp Fire(recreation: $25 ❑?Per Pump $100 30,001-40,000 sq ft $ 1,050.02 Controlled Burn(15da: $100 FIRE ALARM SYSTEM 40,001-60,000 sq ft $ 1,500.02 Hood/Duct $50 0-25 Devices $50 60,001-80,000 sq ft $ 2,100.02 Place of Assembly $50 Annual 80,001-($2,100.02)p er 26 plus Devices $100 ea add 1,000sq ft $ 0.06 Fire Protection $25 SUPPRESSION SYSTEMS (Business closed until .Flammable Application $50 Annual Wet $50 violations corrected) Waste Tire Storage $50 Annual Dry $50 SPRINKLER SYSTEMS Generator<KW $100 CO2 $50 Hydro Undergrounds $45 Generator>30 KW $100 Other $50 Hydrostatic Test $65 per system Bio-Hazard Waste $100 Annual KITCHEN EXHAUST ;Acceptance Test $45 persystem Fumigation Tenting $50 ❑ Hood/Ducts $50 Hydrant Flow $75 Torch Pot/Applied $50 OTHER Haz.Materials $50 Annual IqLP Installation per tank $50 FIRE ALARM SYSTEM Fuel Tank Installation $50 System Acceptance $50 (Per Tank) $50 B Recall Acceptance $50 ❑Natural Gas Installation $50 OTHER (Per System) Fire Wall/Smoke Wall $15 per wall ri Spray Booth $50 LP Gas $25 per tank Natural Gas $25 per system Tent 10'x10'or greater $15 per tent Fire Pump $45 Fire Suppression $30 System Acceptance Exhaust Hood/Duct $30 Re-inspection DBL (other than annual) Inspection scheduled DBL and cancelled less than 24 hours Construction Insp. N/C Emergency Vehicle Acce $50 PLANS TOTAL INSPECTION TOTAL PERMIT TOTAL GRAND TOTAL j Comments: Date: Inspector: see back nlh Providing Construction Solutions Since 1985 Subcontract Number: 192003P002 PO Amount: $1,278.00 Project Number: 192-003- P URCHAS►E ORDER. AGREEMENT made on Thursday,May 24,2018. TO: UNIVERSAL FIRE SYSTEMS, INC. 374 HOBBS ROAD TAMPA, FL 33619 ATTENTION: DOUG 813-662-9200 BY: ABI Companies, Inc. 5425 Beaumont Center Blvd, Suite 900 Tampa, FL 33634 Don Pedretty PROJECT: HUMANA ZEPHYRHILLS GYUIDANCE CENTER Ship To: 7920 GALL STREET ZEPHYRHILLS , FL 33541 Architect: 1A INTERIOR ARCHITECTS, P. C. 2100 PONCE DE LEON BLVD SUITE 1090 CORAL GABLES,FL 33134 Item SOV Description Quantity UM Unit Price Extended Price 1 15-5-10- Relocate and or add sprinklers to comply with 0.000 LS 0.00000 $1,278.00 code and new tenant layout. All labor and materials will conform to NFPA 13. Included in quote are all labor,materials& Florida sales tax, shop drawings and Pasco County permit. TOTAL PO AMOUNT: $1,278.00 pg.1 Bulletin 014 Rev.P . cQ ® p Model F1 FR Series bi Quick Response �. Glass Bulb Sprinklers Model F1 FR56 Sprinkler Types Standard Spray Upright Standard Spray Pendent Conventional Upright/Pendent Vertical Sidewall ram. Horizontal Sidewall Model F1 FR56 Recessed Sprinkler Types Upright Pendent Conventional Standard Spray Pendent R, Horizontal Sidewall Model F1 FR56 Concealed Sprinkler Types Standard Spray Pendent Model Fi FR42i Fi FRXLH & Fi FR28 Sprinkler Typesrf,y w Standard Spray Upright Vertical Sidewall Horizontal Sidewall Recessed Standard Spray Pendent Pendent1FVF2 Model F1 FR40 Sprinkler Types .. Spray Pendent ` '• ¢" Standard � .��"'� Model F1 FR42, F1 FR40, F1 FRXLH & F1 FR28 ` Recessed Sprinkler Types Standard Spray Pendent Model F1 FR56LL&F1 FR42LL Low lead Sprinkler Recessed Concealed Recessed Types Horizontal Sidewall Pendent Pendent/FP Standard Spray Pendent with less than 0.25% Lead r� Content Listing & :t Approvals The following organizations provide Listings or Approvals for various Model F1 FR series sprinklers.See the Design u ;7 and Installation table in this Bulletin for information on specific listings and approvals applicable to each sprin- XLH Upright XLH Pendent XLH Recessed kler. Pendent F1/F2 1. Underwriters Laboratories Inc. and Certified for Product Description -- : Canada(cULus) in accordance with ANSIiUL199, Reliable Model F1FR series sprinklers .,-.,•.- _. -,yam 2. FM Approvals (FM) are quick-response automatic sprin- klers with alass bulb thermal element. 3. Loss Prevention Certification Board (LPGB) g 4. VdS Schadenverhutung GmbH (VdS) Model F1 FR series sprinklers are Stan- 5. Underwriters Laboratories Inc. and Underwriters dard Spray sprinklers, with the excep- Laboratories of Canada Certified for Health Effects tion of the Model F1 FR56 Conventional XLH Recessed to NSF/ANSI Standard 61 Annex G (ULH) sprinkler which is an Old-style/Conven- Pendent FP 6. EC Certificate: 0786-CPD-40239 (RA1414), 0786- tional sprinkler. CPD-40251 (RA1425), 0786-CPD-40252 (RA1475) The Model F1FR Series automatic sprinklers utilize a 3.0 (EC) mm frangible glass bulb.These sprinklers have demonstrat- ed response times in laboratory tests which are.five to ten S Luting Category times faster than standard response sprinklers. This quick Sprinklers,Automatic&Open(VN1V} response enables the Model F1 FR Series sprinklers to apply Quick Response Sprinkler water to a fire faster than standard-response sprinklers of the same temperature rating, The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely man- ufactured glass capsule. This glass bulb is specially con- structed to provide fast thermal response. Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, EIMSford, New York 10523 At normal temperatures, the glass bulb contains the fluid Model F1 FR Series sprinklers must be installed with the in.both the liquid and vapor phases. The vapor phase can Reliable sprinkler installation wrench identified in the Design be seen as a small bubble. As heat is applied, the liquid and Installation Information table in this Bulletin. Any other expands,forcing the bubble smaller and smaller as the liq- wrench may damage the sprinkler. A leak tight sprinklerjoint uid pressure increases. Continued heating forces the liquid can be obtained with a torque of 8 to 18 lb-ft(11 to 24 N-m). to push out against the bulb, causing the glass to shatter, Do not tighten sprinklers over the maximum recommended opening the waterway and allowing the deflector to distrib- installation torque. Exceeding the maximum recommended ute the discharging water. installation torque may cause leakage or impairment of the Model F1 FR Series sprinklers provide a wide range of op- sprinkler. tions where quick-response,glass bulb sprinklers are used: Recessed Sprinklers • Pendent, recessed pendent, upright, horizontal Model F1 FR Series Recessed sprinklers are to be installed sidewall, and vertical sidewall deflectors as shown in Fig. 1,Fig.2,or Fig.3,as applicable to the spe- • K-factors of 2.8 (40 metric), 4.0 (57 metric), 4.2 (60 cific model being installed.The Recessed Escutcheon Data metric), and 5.6 (80 metric) table in the Bulletin identifies the only recessed escutcheons • Flush, recessed, and concealed installations that are permitted to be used with each Model F1 FR Series See the Design and Installation Information table in this Recessed sprinkler.The use of any other recessed escutch- Bulletin for information on the approvals and availability of eon will void all approvals and negate all warranties. specific Model F1 FR series sprinkler configurations. Concealed Sprinklers Model F1 FR Recessed Pendent and Recessed Horizon- Model F1 FR Series Concealed Pendent sprinklers are to tal Sidewall sprinklers are required to be used with Reliable be installed as shown in Fig.4 or Fig.5,as applicable to the Model F1, F2, or FP recessed escutcheons. See the Re- selected cover plate. Model F1 FR56 Concealed Pendent cessed Escutcheon Data table in this Bulletin for listing and and Model F1 FR56LL Concealed Pendent sprinklers have approval information with each specific Model F1 FR series a factory-installed Model CCP cup. A protective cap is in- sprinkler.Model F1 and F2 recessed escutcheons,shown in stalled at the factory that should remain on the sprinkler until Fig. 1 and 3, are a friction fit assembly allowing for 3/4-inch the sprinkler is installed and should then be reinstalled on (19mm) and 1/2-inch (12.7mm) of adjustment, respectively. the_sprinkler until the cover plate is installed.The concealed Model FP recessed escutcheons,shown in Fig.2, provide a sprinkler assemblies are completed by the installation of a 1/2-inch(12.7mm)threaded adjustment. Model CCP push-on/thread-off cover plate assembly. The Model F1 FR56 Concealed Pendent and Model F1 FR56LL cover plate and sprinkler cup assemblies are joined using Concealed Pendent sprinklers are required to be used with a cover plate skirt with flexible tabs for threaded engage- Model CCP cover plates.A standard profile Model CCP cov- ment..A choice of two Model CCP cover plate assemblies er plate is available that provides up to 1/2-inch(12.7mrn)of provides either 1/2-inch (13mm) or 5/8-inch (8mm)of cover cover plate adjustment..ln addition,a low profile Model CCP adjustment. Do not install Model F1 FR Series Concealed cover plate is also available that provides up to 5/16-inch Pendent sprinklers in ceilings which have positive pressure (8.Omm) of cover plate adjustment. See the Design and In- in the space above. stallation Information and Listed and Approved Temperature Model F1FR Series Concealed Pendent sprinklers require a Ratings tables in this Bulletin for further information on ap- 2-5/8-inch (67mm) diameter hole to be cut in the ceiling. The proved cover plate options. Model RC1 wrench is used to engage the sprinkler wrenching Application surfaces and to install the sprinkler in the fitting. Remove the Model F1 FR Series sprinklers are intended for use in protective cap to install the sprinkler,then reinstall the protective accordance with NFPA 13, FM Property Loss Prevention cap until the cover plate is installed. When inserting or remov- Data Sheets, and the requirements of the Authority Hav- ing the wrench from the sprinkler/cup assembly,care should be ing Jurisdiction. Care must be exercised that the k-factor, taken to prevent damage to the sprinkler. Do not wrench any temperature rating,deflector style, and sprinkler type are other part of the sprinkler/cup assembly. Installation is com- in accordance with the requirements of the applicable pleted by removing the protective cap from the sprinkler and design and installation standards. In addition, Model pushing the cover plate onto the Cup.Final adjustment is made F1 FR Series sprinklers must be used in accordance with by hand turning the cover plate until the skirt flange makes full their listings and approvals, as well as the information contact with the ceiling.Cover plate removal requires turning the provided in this Bulletin. cover plate in the counter clockwise direction.After installation, Installation inspect all sprinklers to ensure that there is a gap between the Glass bulb sprinklers have orange bulb protectors or pro- cover plate and ceiling and that the four cup slots are open and tective caps to minimize bulb damage during shipping,han- free from any air flow impediment to the space above. dling and installation. Reliable sprinkler installation wrench- Concealed cover plate/cup assemblies are listed only for es are designed to install sprinklers with bulb protectors in use with specific sprinklers.The use of any concealed cover place.Remove the bulb protector at the time when the sprin- plate/cup assembly other than the Reliable Model CCP with kler system is placed in service for fire protection. Removal Model F1 FR56 Concealed Pendent and Model F1 FR56LL of the bulb protector before this time may leave the bulb vul- Concealed Pendent sprinklers or the use of the Model CCP nerable to damage.Remove bulb protectors by undoing the Concealed cover plate assembly on any sprinkler with clasp by hand. Do not use tools to remove bulb protectors. which it is not specifically listed my prevent good fire pro- tection and will void all guarantees, warranties; listings and approvals. 2. Technical Data: Sensitivity: Quick-response thread Size: 1/2-inch NPT standard; ISO 7-R1/2 optional Maximum Working Pressure: 175 psi (12 bar)- 100% Factory tested hydrostatically to 500 psi (34.5 bar) SIN RA1425, RA1414& RA1435 cULus listed for 250 psi (17 bar) Design and Installation Information Nominal Nominal Nominal Orifice Sprinkler Listings K-factor Deflector/ Installation Approval Model Diameter Orientation Height Wrench SIN and Notes US Metric inches mm inches mm Approvals Pendent 2.25 57 D or W2 RA14111 cULus 2 F1 FR28 2.8 40 3/8 10 Recessed Pendent 2.25 57 GFR2 RA1411 cULus 2 Upright 2.25 57 D or W2 RA1421 cULus 1,2 F1 FR40 4.0 57 3/8 10 Pendent 2.25 57 D or W2 RA1418 VdS Recessed Pendent 2.25 57 GFR2 RA1418 VdS Pendent 2.25 57 D or W2 RA1413 cULus 2 F1 FR42 4.2 60 7/16 10 Recessed Pendent 2.25 57 GFR2 RA1413 cULus 2 Upright 2.25 57 D or W2 RA1423 cULus 1,2 F1 FR42LL 4.2 60 7/16 10 Pendent 2.25 57 D or W2 RA1410 cULus, ULH Recessed Pendent 2.25 57 GFR2 RA1410 cULus, ULH F1 FRXLH Pendent 2.25 57 D or W2 RA1413 cULus 2 (F1 FR42 4.2 60 7/16 10 Recessed Pendent 2.25 57 GFR2 RA1413 cULus 2 with Pintle) Upright 2.25 57 D or W2 RA1423 cULus 1,2 Pendent 2.25 57 D or W2 RA1414 cULus, FPA, 1,2,3,4 LPCB,VdS, EC Recessed Pendent 2.25 57 GFR2 RA1414 cULus,FM, 1,2,3,4 LPCB,VdS, EC F1FR56 5.6 80 1/2 15 Concealed Pendent 2.25 57 RC1 RA1414 cULus,VdS,EC 5,6 Upright 2.25 57 D or W2 RA1425 cULus,FPA: 1,2,3,4 ILPCB,VdS,EC "Conventional 225 57 D or W2 RA1475 LPCB,VdS, EC 4 (Pendent or Upright)" Pendent 2.25 57 D or W2 RA1415 cULus, ULH 1 F1 FR56LL 5.6 80 1/2 15 Recessed Pendent 2.25 57 GFR2 RA1415 cULus, ULH Concealed Pendent 2.25 57 RC1 RA1415 cULus, ULH 6 Horizontal Sidewall 2.63 67 D or W2 RA1435 cULus,FM 1,2,3,7 F1 FR56 5.6 80 1/2 15 Recessed Horizontal 2.63 67 GFR2 RA1435 cULus,FM 8 Sidewall F1 FR56 5.6 1 80 1/2 15 Vertical Sidewall 2.25 57 D or W2 RA1485 cULus,FPA' 1,2,3,9 (Pendent or Upright} LPCB (1)cULus Listed Corrosion Resistant sprinkler when ordered with available Polyester coating. 12)cULus Listed Corrosion Resistant sprinkler when ordered with available Electroless Nickel PTFE plating. Available with FM approved Polyester coating in black or white. fd>Available with LPCB and VdS approved Polyester coating. 5j VdS and EC approvals of the F1 FR56 Concealed Pendent sprinkler are for 155°F(681C)temperature rated sprinklers only.VdS approved sprin- klers must use Norbulb brand glass bulbs with the 1/2-inch(12.7mm)adjustment Model CCP cover plate only. (6)Model F1 FR56 Concealed Pendent and Model F1FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates, available as either standard depth with 1/2-inch(12.7mm)of adjustment or low profile with 5/1 6-inch(8.0 mm)of adjustment.- M cULus Listing of the F1 FR56 Horizontal Sidewall sprinkler is for Light and Ordinary Hazard occupancies only. Minimum to maximum deflector to ceiling distance shall be 4-inches to 12 inches(102mm to 305mm).FM Approval of the F1 FR56 Horizontal Sidewall sprinkler is for Light Hazard occupancies only. !61 cULus Listing and FM Approval of the F1 FR56 Recessed Horizontal Sidewall sprinkler is for Light Hazard occupancies only. (9)The F1 FR56 Vertical Sidewall sprinkler is listed and approved for use only in Light Hazard occupancies.LPCB approval of the F1 FR56 Vertical Sidewall sprinkler is for installation in the Pendent position only. 3. Listed and Approved Temperature Ratings Ordinary Temp. Intermediate Temp. High Temp. Classification Classification Classification Deflector/ 100°F(38°C) Max.Ambient 150°F(65°C) Max.Ambient 225OF(107°C) Max. Model Orientation o Temp. Temp. Ambient Temp. 135o F(57 C) 155o F(68a C) 175o F(790 C) 200o F(93o C) 286 F(141 C)Temp. Temp. atin Temp.Rating Temp. Rating Temp.Rating Rating Orange Bulb Red Bulb I Yellow Bulb Green Bulb Blue Bulb Pendent cULus 01FR28 Recessed Pendent cULus Upright cULus F1FR40 Pendent VdS Recessed Pendent VdS — Pendent cULus F1FR42 Recessed Pendent cULus Upright cULus FlFR42LL Pendent -- cULus,ULH — Recessed Pendent -- cULus,ULH — Pendent cULus F1FRXLH Recessed Pendent cULus Upright cULus Pendent cULus,FM, LPCB,VdS, EC Recessed Pendent cULus,FM, LPCB,VdS, EC -- FiFR56 Concealed Pendent' cULus cULus,VdS,EC I cULus Upright cULus, FM, LPCB,VdS, EC "Conventional LPCB,VdS, EC (Pendent or Upright)" Pendent -- cULus, ULH -- FiFR56LL Recessed Pendent — cULus,ULH — Concealed Pendent` -- cULus, ULH -- Horizontal Sidewall cULus, FM F1FR56 Recessed Horizontal cULus, FM — Sidewall F1FR56 Vertical Sidewall(Pen- cULus, FM, LPCB dent or Upright) * Model F1 FR56 Concealed Pendent and F1 FR56LL Concealed Pendent sprinklers must be used with Reliable Model CCP cover plates. For Ordinary Temperature Classification sprinklers use a 135°F (57°C) temperature rated.cover plate. For Intermediate Temperature Classification sprinklers use a 1650F(74°C)temperature rated cover plate. Recessed Escutcheon Data Listed and Approved Recessed Escutcheons Deflector/ Model F1 Model F2 Model FP Model Orientation (Fig. 1 &3) (Fig.1 &3) (Fig.2) SIN 3/4-inch(19mm) 1/2-inch(12.7mm) 1/2-inch(12.7mm) adjustment adjustment adjustment F1FR28 Recessed Pendent cULus cULus cULus RA1411 F1FR40 Recessed Pendent VdS VdS VdS RA1418 FIFR42 Recessed Pendent cULus cULus cULus RA1413 FlFR42LL Recessed Pendent cULus, ULH cULus, ULH cULus, ULH RA1410 FIFR42XLH Recessed Pendent cULus cULus cULus RA1413 FIFR56 Recessed Pendent cULus,LPCB,VdS, cULus,FM, LPCB, cULus,VdS, EC RA1414 EC VdS, EC Fi FR56LL Recessed Pendent cULus, ULH cULus, ULH cULus, ULH RA1415 FlFR56 Recessed Horizontal Sidewall cULus cULus,FM cULus RA1435 4. 2 114-HOLE DLL [57.2mm] 1 15/16-D14 [49.2mm] I"X 1/2" REDUCER TURN COLLAR UNTIL TIGHT AGAINST SPRINKLER WRENCH BOSS \ / FACE OF FITTING / TO FACE OF CEILING DIMENSION F1 ESCUTCHEON II II AT MAXIMUM RECESS - 1[25.4mm] L J AT MINIMUM RECESS = 3/8'[9.5mm] Fl ESCUTCHEON t fY�//1/1/ F2 ESCUTCHEON 3/4'T19mm] AT MAXIMUM RECESS = 3/4[19mm] ADJUSTMENT ,� AT MINIMUM RECESS = J18[9.5mm] F2 ESCUTCHEON 1/2[12.7mm] ADJUSTMENT F1 ESCUTCHEON AT MAXIMUM RECESS = 7/8"[22.2mm] [3.2mm] AT MINIMUM RECESS = 1-5/8"[41.Jmm] F2 ESCUTCHEON AT MAXIMUM RECESS = 1-1/8'T28.6mm] AT MINIMUM RECESS = 1-5/8[41.Jmm] 2 27/32"DR [72.2mm] Fig. Model F1 FR56,F1 FR56LL,F1 FR42,F1 FR40,F1 FR42LL,F1 FRXLH&F1 FR28 Recessed Pendent sprinkler with Model F1 or F2 escutcheon I I 1" X 1/2" REDUCER -----I----- 2 5/8" DIA. [66.7mm] HOLE /N CEILING 2 5/16" DIA. [58.7mm] CUP L J CEILING - FACE OF F17TING 0 TO FACE OF CEILING DIMENSION �- AT MAXIMUM RECESS = 1-1/2[J8mm] AT MINIMUM RECESS = 1[25.4mm] I AT MAXIMUM RECESS = 9/16[14.3mm] %2[12.7mm] AT MINIMUM RECESS = 1[25.4mm] ADJUSTMENT 3 1/4" DIA. [82.6mm] Fig. Model F1 FR56,F1 FR56LL,F1 FR42,F1 FR40,F1 FR42LL,F1 FRXLH&F1 FR28 Recessed Pendent sprinkler with Model FP escutcheon 5. FACE OF FITTING TO FACE OF CEILING DIMENSION F1 ESCUTCHEON AT MAXIMUM RECESS = 1'T25.4mm] AT MINIMUM RECESS = 3/8'[9.5mm] F1 ESCUTCHEON F2 ESCUTCHEON AT MAXIMUM RECESS = 1-3/8'T34.9mm] AT MAXIMUM RECESS = 3/4'T 19mm] AT MINIMUM RECESS = 2-1/16'T52.4mm] AT MINIMUM RECESS = 3/8'T9.5mm] F2 ESCUTCHEON AT MAXIMUM RECESS = 1-5/8'T41.3mm] 2 114" HOLE DIA. AT MINIMUM RECESS = 2-1/16'T52.4mm] [57.2mm] [3.2mm] 1" X 112" REDUCER _ I I�IIIIIII I `\�7 (1) I IIIIII I 4'-12" 1 15116" DIA. [49.2mm] III [101.6mm—J04.8mm] I iiii I 2 27/32" DIA. CEILING TO [72.2mm] DEFLECTOR I TURN COLLAR UNTIL TIGHT AGAINST WRENCH BOSS.SPRINKLER F1 ESCUTCHEON 3/4 719mm] ADJUSTMENT F2 ESCUTCHEON 1/2'[12.7mm] ADJUSTMENT orvms RECESSED HSW W/F1 OR F2 ESCUTCHEON (1) FM APPROVED FOR 4" — 6" [101.6MM — 152.4MM] CEILING TO DEFLECTOR WITH F2 ONLY. Fig.3 Model F1 FR56 Recessed Horizontal Sidewall sprinkler with Model F1 or F2 esCutcheon 1"' x 112" REDUCING TEE OR ELBOW — — - ---------+-------- ---- -------- ----2-5/8„ DIA. 2 5116 DIA — ? HOLE IN CEILING L_ -1 CUP du 1 112" MAX. FACE OF FITTING TO FACE OF CEILING ; DIMENSION CEILING _ � I 112" MAX. 15/16" COVER ADJUSTMENT j COVER PLATE — ASSEMBLY /3 5116" DIA. SPRINKLER CONCEALED, 1/2" ADJUSTMENT 017FG01A Fig.4 Model F1 FR56/F1 FR56LL Concealed Pendent sprinkler with standard depth 1/2-inch(12.7mm)adjustment-Model CCP cover plate 6. ` TEE OR ELBOW FACE OF FITTING TO FACE OF CEILING DIMENSION CEILING J t COVER ADJUSTMENT COVER PLATE SPRINKLER CONCEALED, 5/16" ADJUSTMENT G17FG0ZA Fig.5-Model F1 FR56/F1 FR56LL Concealed Pendent sprinkler With low profile 5/16-inch(8.Omm)adjustment-Model CCP cover plate Maintenance The Model F1FR Series sprinklers should be inspected and Material Data the sprinkler system maintained in accordance with NFFA Frame: DZR Brass,QM Brass,or Low Lead Brass 25.Do not clean sprinklers with soap and water,ammonia or any other cleaning fluids.Remove dust bv using a soft brush cx gentle vacuuming.Replace any sprinkler which has been painted(other than factory applied) 'or damaged in any way. Washer: Nickel Alloy 440 or 360,coated with PTFE A stock of spare sprinklers should be maintained to allow Adhesive Tape quick replacement of damaged or operated sprinklers. Bulb: Glass FinishesU> Standard Finishes Sprinkler Escutcheon Cover plat (1) Ordering Information Bronze — Brass Chrome Specify: Chrome Plated Chrome Plated White Polyester Coated(460) White Painted 1. Sprinkler Model: [F1FR28][F1FR4O][F1RR42] —Special Application Finishes [F1FR42LL][F1FRXLH][F1FR58l|F1FR50LLl Sprinkler I Escutcheon Cover plateM 2. Sprinkler DoOeobor/Ohenbatinn: [PenU8nU[Recessed Electroless Nickel Electroless Nickel Bright Brass Pendent][UphghU[[|onv8ntiomd][Horizontal Sidew8|] Briqht Brass(') ff-right Brass Black Plating— [Recessed Horizontal S|dewaU](Vertic8/ SidevvoU] 3. Sprinkler threads: /1/2-nChNPT [|GO7-R1/2] Black Paint`21(6) Black Paint Off White 4. Sprinkler Temperature Rating: [135oF (570O)][155»F Off White(2)fe) Off White Satin Chrome� K68"CD[175*F(79«C)][200oF(93^C)]C280«FU U Chrome Dull I Chrome Dull 41�� 01 Other finishes and colors are available on special order, Consult the 5` Sprinkler Finish factory for details.Custom color painted sprinklers may not etain their 0` Escutcheon Model: [F1][F2][Fp] UL Corrosion resistance listing.Coverplate custom paint is semi-gloss, 7. Escutcheon Finish (where applicable) wun�anopeo�edu�en«�e' 8. Cover plate K�odd� [ot�ndundp��i|'� CCP 1/2-inch cU�mU�mdon� � ^ P1 200OF(930C)maximum, (12.7mm) adjustment][low profile CCP 5/16-inch (4) cULum U**d "corrosion resistance" applies mSIN Numbers RA1435 (8.Ornnn) acjuStmentl (HGW). RA14O5(VGW). RA1425 (Upright), RA1414 (Pendent) and 0. Cover plate Temperature Rating:[135^F(57»{')for use RA1415 (Pendent) in standard black mwhite. Corrosion resistance in with Ordinary Temperature aphnk|erS ^1G5o (74«C)o�n,pu4m�arco�mixmmi|uU|oupuneque� w FM ovals for use««�h InbarnOeUiateTemperature 8pri;Nom] RA1414.RA1435and RA1425|n standard black mrwhite. 1O. Cover plate Finish (6)LPCB and VdG Approved finish applies only toRA1425.R81414.RA1418 m(W����14� �� �� ��| F1FR �h� R���d �h��m � �� � nU�s�uwUConox�nReain�m ' sprinklers and escutcheons are packaged separately. elible . . . For Complete Protection Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. * .Automatic sprinklers • Deluge valves • Flush automatic sprinklers Detector check valves • Recessed automatic sprinklers Check valves • Concealed automatic sprinklers Electrical system • Adjustable automatic sprinklers Sprinkler emergency cabinets • Dry automatic sprinklers • Sprinkler wrenches • Intermediate level sprinklers • Sprinkler escutcheons and guards • Open sprinklers Inspectors test connections • Spray nozzles • Sight drains • Alarm valves Ball drips and drum drips • Retarding chambers • Control valve seals • Dry pipe valves • Air maintenance devices • Accelerators for dry pipe valves • Air compressors • Mechanical sprinkler alarms • Pressure gauges • Electrical sprinkler alarm switches • Identification signs • Water flow detectors • Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association,Factory Mutual Research Corporation,or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for almost 100 years. Manufactured by Reliable Automatic Sprinkler Co.,Inc. Recycled ® (800)431-1588 Sales Offices Paper Relle labi (800)848-6051 Sales Fax Revision lines indicate updated or new data. (914)829-2042 Corporate Offices wtjw.reliablesprinkler.com Internet Address EG.Printed in U.S.A.11/17 p/N 9999970300 ]L UNI VERSAL FIRE SYSTEMS INC. 374 Hobbs Road•Tampa,FL 33619 (813)662-9200 9 Fax 662-0080 PIPE SPECIFICATION ALL PIPING SHALL MEET THE REQUIREMENTS OF N.F.P.A. 13, INSTALLATION OF SPRINKLER SYSTEMS. PIPING SHALL MEET THE REQUIREMENTS OF EITHER STANDARD ASTM A 795, ANSI/ASTM A 53, ANSI B36.10M OR ASTM A 135. THREADED PIPING WILL BE SCHEDULE 40. ROLL GROOVE PIPING WILL BE SCHEDULE 10. TYPE AND MANUFACTURER OF PIPE WILL BE AT THE DISCRETION OF THE SPRINKLER CONTRACTOR BASED ON AVAILIBILITY, BUT WILL MEET AT LEAST ONE OF THE SPECIFICATIONS MENTIONED ABOVE. FITTING SPECIFICATION ALL FITTINGS SHALL MEET THE REQUIREMENTS OF N.F.P.A. 13, INSTALLATION OF SPRINKLER SYSTEMS. FITTINGS SHALL BE U.L. LISTED AND MEET THE REQUIREMENTS OF EITHER STANDARD ANSI B16.1, ANSI B16.3, ANSI B16.4 ANSI B16.5, ANSI B16.9, ANSI B16.11, ANSI B16.25, ASTM A 234, ASTM 234 OR ASTM A 536. TYPE AND MANUFACTURER OF FITTINGS WILL BE AT THE DISCRETION OF THE SPRINKLER CONTRACTOR; BASED ON AVAILIBILITY, BUT WILL MEET AT LEAST ONE OF THE SPECIFICATIONS MENTIONED ABOVE. SALES SERVICE INSPECTIONS REPAIRS Fig. 69 Adjustable Swivel Ring, Tapped Per NFPA Standards Size Range:'/z"through 8" s ar Material:Carbon steel Finish:Strap is Pre-Galvanized Zinc Material. Nut is Zinc Plated. `- Service:Recommended for suspension of non-insulated stationary pipe line. "fir ZV Maximum Temperature:450•F Approvals:Complies with Federal Specification A-A-1192A(Type 10), WW-N-777-E(Type 70), r { and ANSI/MSS SP-58(Type 10).UL Listed and FM Approved(Sizes 3/4'-8"). Features: • '/z"-T sizes designed for use with steel and CPVC piping and manufactured with FBC System Compatible oil. • Threads are countersunk so that they cannot become burred or damaged. ,x. �a • Knurled swivel nut provides vertical adjustment after piping is in place. i = • Captured swivel nut in the'/z"through 6"sizes.The capture is permanent in the bottom " ;a,•. portion of the band,allowing the hanger to be opened during installation if desired,but not allowing the nut to fall completely out. , Ordering:Specify size,figure number and name. /i'through 2"Size Non-captured nut also available upon request. �A Rounded Edge Design A_ C U1 us FM —_ USTED APPROVED F C B +Q +Q + G G F 1/2"through V pipe 1'/4"through 2'pipe 21/2"through 8"pipe f` FIG. 69:LOADS (LBS) • WEIGHT (LBS) • DIMENSIONS (IN) Pipe Size Max Load Weight Rod�Size B C F Width /z 0.10 2/8 2 1/1s : 3/a 0.10 23/4 11/8 15/1s 1 0.10 29/is 111/16 1 5 300 0.10 2% 13/a 0.10 % 23/4 11/8 2 0.11 3'/4 23/a 525 0.20 4 23/4 15/1s 3 0.20 313/is 215/,s 13/1s w,rrtn 4 650 0.30 411/ts 313/1s 5 0.54 55/is 43/8 19/'s 'A2'/z"through 8"Size 2Y2 6 1,000 0.65 1/26"/16 59/6 2'/4 M8 1.00 PROJECTi • APPROVAL Project: Approved Address: ❑Approved as noted Contractor: ❑Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: PH-3.17 BEAM CLAMPS Fi • 92 Universal C-type Clamp (Standard Throat) Size Range:3/8"and 1/2' Material:Ductile iron,hardened steel cup point set screw and locknut. Finish:❑Plain or❑Zinc Plated(Hot-Dip Galvanized optional) Service:Recommended for use under roof installations with bar joist type construction, or for attachment to the top or bottom flange of structural shapes where the vertical hanger rod is required to be offset from the edge of the flange and where the thickness of joist or flange does not exceed'/a: Approvals:Complies with Federal Specification A-A-1192A(Type 19&23) WW-H-171-E(Type 23),ANSI/MSS SP-69 and MSS SP-58(Type 19&23). UL,ULC Listed and FM Approved. How to size:Size of clamp is determined by size of rod to be used. f Installation:Follow recommended setscrew torque values per MSS-SP-69. Features: • They may be attached to horizontal flanges of structural members in either the top beam or bottom beam positions. • Secured in place by a cup-pointed Set Screw tightened against the flange. g@Us Fm A jam Nut is provided for tightening the Set Screw against the Body Casting. LISTED APPROVED • Thru tapping of the body casting permits extended adjustment of the threaded rod. • Can be used with Fig 89X retaining clip for seismic applications. Ordering:Specify rod size,figure number,name of clamp and finish. f H E F C AT LEAST ONE I~ — G I FULLTHREAD — OF ROD MUST BE EXPOSED i -. //a' I D BODY } CASTING JAM-NUT �A - SETSCREW FIG. 92: LOAD (LBS) • WEIGHT (LBS) • DIMENSIONS (IN) • TORQUE(IN-LBS) Rod Size Set Screw Torque Max Loads■ Weight C D E F G H A Size Value Top Bottom 3/8 % 60 500 250 0.34 15/16 19/6 9/1r, 13/is % 1/z 1/2 1/z 125 950 760 0.63 1% 113/6 1/x 11/16 'A6 23/32 ■Maximum temperature of 450°F PROJECTI Project: ❑Approved Address: ❑Approved as noted Contractor: ❑Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: PH-1.15 HANGER RODS Fig. 146 Continuous Threaded Rod Size Range:'/a"through 1'/z'Stocked in six,ten,and twelve foot lengths.Other even foot lengths can be furnished to order. Material:Carbon steel or Stainless Steel Gr 304 Threads:National Coarse(USS),rod threaded complete length. Finish:❑Plain or❑Zinc Plated(Hot-Dip Galvanized optional) Maximum Temperature:650•F. Ordering:Specify rod diameter and length,figure number, name and finish. Note:The acceptability of galvanized coatings at temperatures above 450•F is at the discretion of the end user. FIG.146: LOADS(LBS)*WEIGHTS(LBS)®DIMENSIONS(IN) Rod Size Threads Max Load Weight A per inch 660•F per Ft. Length '/a 20 240 0.12 j % 16 730 0.30 1/z 13 1,350 0.53 t 1/8 11 2,160 0.84 A 3/a 10 3,230 1.20 1/8 9 4,480 1.70 1 8 5,900 2.30 11/4 1 7 1 9,500 1 3.60 11/z 1 6 1 13,800 1 5.10 Note:Other rod sizes available upon request.Class 2 fit is available upon request. PROJECT , Project: []Approved Address: ❑Approved as noted Contractor: ❑Not approved Engineer: Remarks: Submittal Date: Notes 1: Notes 2: PH-1.15