Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
18-19972
CITY OF ZEPHYRHILLS 5335-8TH STREET. - (813)780-0-020 19972 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL PERMIT-INFORMATION LOCATION INFORMATION Permit#:19972 Issued: 7/30/2018 Address: 6574 WAGON TRAIL ST Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 332,430.15 Total Fees: 11,682.19 Subdivision: SILVERADO Amount Paid: 11,682.19 Date Paid: 7/30/2018 Parcel Number: 05-26-21-0080-00600-0120 CONTRACTOR INFORMATION OWNER INFORMATION Name: DR HORTON INC Name: DR HORTON INC Addr: 12602 TELECOM DR Address: 12602 TELECOM DR TAMPA, FL. 33637 . TEMPLE TERRACE FL 33637-0935 Phone: Lic: Phone: 813-549-1968 Work Desc: CONSTRUCT SINGLE FAMILY 2,951 SQ FT APPLICATION FEES BUILDING FEE 1,282.68 ELECTRICAL FEE 266.40 PLUMBING FEE 177.60 MECHANICAL FEE 124.32 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE-sfr/100% 4,828.00 SCHOOL IMPACT FEE-sfr/1% 48.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32 Ins ecti ' s Required FOOTER 2ND ROUGH PLUMB Misc INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPECTION FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications and Must Accompany Application.All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. 7 CONTRACTORS SIGNATURE PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER o Q , • �-at►�_s%�--'pie-.,,. City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: -17 � Date Received: Site: Permit Type: f z YZ 2 S Approved w/no comments:❑ Approved w/the below comments: Denied w/the below comments: ❑ This comment sheet shall be kept with the permit and/or plans. -% - Kalvin itz r Plans Examiner Date Contractor and/or Homeowner (Required when comments are present) INSTR#2018099751 ORBK974OPG2167 Page I of I 06/13/2018 11:22 AM Rcpt 1965388 Rec:10.00 DS:0.00 IT:0.00 pauCa S. QWH4 Ph.D, Pasco County cCerk&comytrotrer Pe.rmit No. Parc:l�l:b No C6-26a 2 1 COO C1�00-01—Z-C NOTICE OF COMMENCEMENT State of Florida- County of PaSCO THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 713,Florida Statutes, the following information is provided in this Notice of Commencemerlt: It 1 Description of Property: Parcel Identification No. Z,1[r,( (C', efe.l4r) hI t� , Q- Street Address: 6 A 90 C e'1 I -e-li. --rPA�j f �J- j 7 d- 2. General Description of Improvement New Single Family Residence 3. Owner Information or Lessee information if the Lessee contracted for the improvement: D.R. Horton. Inc Name 19609 TPIP-rf)m neimp Tampa 33637 Address City State Interest in Property: Fee Simple Name of Fee Simple Titleholder. (if different from Owner listed above) Address city State 4. Contractor. D.R. H0ftOn. 1171C Name 12602 Telecom Drive Tampa .33637 FL Address city State Contractor's Telephone No.: 5. surety: N/A Name Address city State Amount of Bond: $, N/A Telephone No.: 6. Lender. N/A Name Address city state Lender's Telephone No.: 7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)M,Florida Statutes: David Gude Name 12602 Telecom Drive Tampa 33637 FL Address city State Telephone Number of Designated Person: 813-740-9720 8. In addition to himself,the owner designates NIA Of to receive a copy of the Uenor's Notice as provided in Section 713.13(1)(b),Florida Statutes. Telephone Number of Person or Entity Designated by Owner: 9. Expiration date of Notice of Commencement(the expiration date may not be before the completion of construction and final payment to the contractor,but will be one year from the date of recording unless a different date is specified): WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalty of perjury,I declare that I have read the foregoing notice of commencement and that the facts stated therein are true to the best of my knowledge and belief. STATE OF FLORIDA COUNTY OF PASCO 214 Sig taturd-of Owner or Lessee,or Owner's or Lessee's Authorized Offi r/Oirector/Partner/Manager Assistant Secr-e-tandD.R. HoEton. Inc Signatory's Title/Office The foregoing instrument was acknowledged before me this22_day ofi6c&:�,-,—,20J.�'by V\4U-,QA as Assistant Secrelaw (type of authority,e.g.,officer,trustee,attorney in fact)for D.R. Horton. Inc (name oAparty on behalf of whom instrument was executed). Personally Known 1A OR Produced Identification EJ Notary Signat r , Type of Identification Produced Name(Print). qWP- Notary public Stato of Florida Michelle MOYOS My Commission 00 057321 Expires 12121/2020 wpdatalbes/noticecommencement_pc053048 DR Horton-6574 Wagon Trail St-2,951 sq ft Column ts SQ. FEET PRICE MAIN OR LIVING: 2,951 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 332,430.15 FEE SHEET $ 1,184.00 ADDRESS $ 30.00 DRIVEWAY $ 45.00 BUILDING: $ 1,282.68 ELECTRICAL: $ 266.40 PLUMBING: $ 177.60 MECHANICAL: $ 124.32 SUB-TOTAL $ 1,851.00 TOTAL $ 1,851.00 SEWER: n/a WATER: n/a IRRIGATION: $ - TOTAL: $ - WATER METER: n/a IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 2,404.35 PARK IMPACT FEES $ 769.56 SIF'S: $ 4,828.00 100.0% $ 4,828.00 1.0% $ 48.28 TOTAL: $ 4,876.28 T i F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ -11,682.19 D.R. Horton-6574 Wagon Trail St:2,951 sq ft Column Es SQ. FEET PRICE MAIN OR LIVING: 2,951 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 332,430.15 FEE SHEET $ 1,187.00 ADDRESS $ 40.00 DRIVEWAY $ 40.00 BUILDING: $ 1,290.74 ELECTRICAL: $ 267.08 PLUMBING: $ 178.05 MECHANICAL: $ 124.64 SUB-TOTAL $ 1,860.50 TOTAL $ 1,860.50 SEWER: n/a WATER: n/a IRRIGATION: $ - TOTAL: $ - WATER METER: n/a IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 2,413.85 PARK IMPACT FEES $ 769.56 SIF'S: $ 4,828.00 100.0% $ 4,828.00 1.0% $ 48.28 TOTAL: $ 4,876.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 11,691.69 913-780-0020 City of Zephyrhills P_er'mit Application Fax alsaeo-0021 Building Department Date Received Phone Contact for Permitting -" Owner's Name tr t t t� r-. �= .Owner Phone Number '52 Owner's Address «�'����') �`� '"� `� �G�t..fp�E J Owner Phone Number Fee Simple Titleholder Name Owner Phone Number Fee Simple Titleholder Address aos ADDRESS' '� r ( i f 5 Ft 3� LOT# .SUBDIVISION �✓JiJ1>•e_r� PARCEL ID# Yw (OBTAINED FROM PROPERTY TAX NOTICE) ' WORK PROPOSED NEW CONSTR INSTALL 8 ADD/ALT SIGN � DEMOLISH ; REPAIR PROPOSED USE t9— SFR 0 COMM OTHER TYPE'OF CONSTRUCTION . �''r BLOCK FRAME ��. STEEL 0 DESCRIPTION OF WORK BUILDING SIZE �_ - SQ FOOTAGE Z"��2 S HEIGHT re-P�t-'t-r'�'-7r-t-t-rr-r�r-r r"r-r-r-sr^re->t-t-mrp-�-➢-9-�-e-r->r rr-e-r-o-¢-ra =BUI.LDING $ VALUATION OF TOTAL CONSTRUCTION =ELECTRICAL $. AMP SERVICE PROGRESS ENERGY 0 W.R.E.C. =PLUMBING $ MECHANICAL $ V VALUATION OF MECHANICAL INSTALLATION J c� J`�p� = Tz- 1 =GAS ROOFING 0 SPECIALTY r OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO -4-¢--➢-4- -i-31-$-➢----1-➢-1-➢--Fi--i-➢-i-4 1-4 1 ➢--; 11-a-1-4-- BUILDER � = COMPANY _ -�C?�'�-c' _�' fn C SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address %c t�t� l� rt•"C 117 101- )�ia� � License# 013, CG5cl-0 6- a ..F-LECTRICIAN '�� rr, COMPANY G�r��i ��?,F� 3 {` 5- SIGNATURE / REGISTERED Y/ N FEE CURREN Y/N Address a5 —'�r""� ,"� r .rl License# PLUMBER ,, "`' _ COMPANY ••.a ��L' r311 � SIGNATURE REGISTERED Y/ N FEE CURREN Y/N .Address Qi.�r1� `t Fr�,j *t/. /7� .'R a License# MECHANICAL ter, COMPANY /""��i ' /!G{** �d� SiGNAi'URE f 6,"e�-l- afir Ic,^� -.REGISTEREi I Yl N I FEE CURREN Y/N Address � � G F /}�,' fvsa a Fre,,t!,Z'J`� j License# f� d6 � _. 14 OTHER Y_.-r- '- COMPANY �� SIGNATURE ` - REGISTERED Y/ N FEE CURREN Y/N Address License# 1 1 ! ! ! ! ! 1 1' i ➢ ➢ ! ➢ 1 1 i ➢ ! 1 ➢ t ➢ i ➢ i ➢ 1 i ➢ ➢ i 1 1 ➢ @ 1 @ ➢ ! i 1 ! ➢ 1 ! ! ➢ ➢ 1 @ ➢ ! @ i e ➢ @ @ @ @ 8 ➢ @ ➢ 00 RESIDENTIAL Attach (2) Plot Plans; (2)sets of Building Plans; (1)set of Energy Forms; R-O-W Permit.for new construction, Minimum ten (10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Siit.Fence installed, Sanitary Facilities&1 dumpster;Site Work'Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets of Building Plans plus a Life Safety Page; (1)set of Energy Forms. R-O-W Permit for new construction: Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt Fence installed, Sanitary Facilities&1 dumpster.Site Work Permit for all new projects.All commercial requirements must meet compliance SIGN PERMIT Attach(2)sets of Engineered Plans. "PROPERTY-SURVEY required for all NEW construction. -1-➢--E--l-d..➢--6-@-•@--�•.-f-➢--i-.1.-D--;-i�➢-9.-m-➢-@--➢-1-b-.6..•➢--1,-@-»i..&-➢-b-1�-@-11-➢-�-➢--@-.E-@-@--@-➢--$.-9•g&-@--1°.i,.�➢�t;9.miS�-@-@ -@.-@-a-/-➢•-• Directions: Fill out appiicatIon completely. Owner�Contractor sign back of application, notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over$7500) Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner auihorizing same AVER THE COUNTER PERMITTING (copy of contract required) leroofs•if shingles • Sewers Service Upgrades A/C Fences (Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW 05-26-21-0080-00600-0120 Pasco County Property Appraiser Page 1 of 1 Data Current as Of: Weekly Archive - Saturday, July 14, 2018 Parcel ID 05-26-21-0080-00600-0120 (Card: 001 of 001) Classification 00 - Vacant Residential Mailing Address ::Property Value DR HORTON INC Ag Land $0 12602 TELECOM DR Land $2,413 TEMPLE TERRACE FL 33637-0935 Building $0 Physical Address Extra Features $0 6574 WAGON TRAIL STREET ZEPHYRHILLS, FL 33541 Just Value $2,413 Legal Description (First 4 Lines) Assessed (Non-School Amendment 1) $2,413 SILVERADO RANCH SUBDIVISION PHASES 6, 8 &9A PB 75 PG 075 Taxable Value $2,413 BLOCK 6 LOT 12 Jurisdiction City of Zephyrhills Land Detail (Card: 001 of 001) Line Use _IDescription;Zoning !Units_ -Type ___!Price_ !Condition jy_allue _ 1 �j -0100 SFR MPUD 6,0_0_0._00 _ SF _I $0.40 1.00 $2,400 2 0100 I SFR MPUD j 50.00� SF j $0.25` �1.00 j $13 Additional Land_In_formation Acres I 0.14 Tax Areal 30SI FEMA T - Residential Code j SLVRCPI I i I i Code Building Information - Use 00 - Unimproved (Card: 001 of 001) Unimproved Parcel 00 - Unimproved Extra Features (Card: 001 of 001) Line ption 1Descrl T ------------ ---- -------__ (Year Units __------:.Value No Extra Features Sales History- See All 6 sales Previous Owner: DUNE FL LAND I SUB LLC Month/Yearj Book/Page -- Type -_--� _ DOR Code Condition lAmount 05/2018 �9725 / 0407 Warranty Deed _ 05 Vacant Multi-Parcel Sale 05/2017 9535 / 0546 _Certificate of Title _—_� 05 _-j Vacant !Multi-Parcel Sale 11/2016 19462 030384—lM eni ral Rights or Royalty Transfer 0 I Vacant Multi-Parcel Sale http://search.pascopa.com/parcel.aspx?parcel=2126050080006000120 7/18/2018 . , : Sing e ami y. we ing P lan Review Comments l: F.F.E. shall be a minimum of 8"_above.the road.elevation:and an engineered.site_plan. . . 2. Lots shall be graded to,comply with R401.3 of the F.R.C. .: 3.: ,Compaction test required if'24" or more:of fill-dirt is.brought in:at any one place: 4. .Tie in.survey required before pouring concrete.. 5.. -Driveways:require a-R.O.W. use permit: All 4sides of driveway thru the sidewalk shall have expansion material:. :. . „ 6.. .All setbacks.shall be met.. 7.: ;All.property.markers shall be.uncovered:and marked at time of first inspection: .8'. A11 A:D.A:requirements shall be met.: . 9. No electric,plumbing,.mechanical;.or framing shall be covered without an:inspection and _ approval first. 10. All.Garages shall comply:with:section R302.6_of the F.B.C.: (Fire S:eparation). . 11. Appliances shall:not installed in:a�location where siibjectto.mechanical damage unless pfotected:'by approved barriers. M303.4 of.the F.B:C. 12. Water_heaters shall comply.with section:P667.3 of the F.R.C: 13. Foundation supports for.A/C.units shall be raised at least 3'.' above finished gr de.. M1308.1. 14. Return air in all,bedrooihs.,F.B.C. .Ml620,4 15.;Smoke detectors are.to be installed.in accordance4ith:R313:.1 of the.F.B.C. :.16. All glazing requirements are:.to be in accordance with R308.4_of the.F.B.C. 17. All means,of egress are to be in accordance with R31 Lof the F:B.C.. 18. `.`Green gypsum.board" shall-not be used:as.a backer in showers:or tubs. R702.4.2-F.B.C: . 19. Combination-type AFCI breakers.are required;at all.locations requiring_an AFCI_type breaker: 20. Carbon monoxide.alarms:will be required in new:construction that uses fossil-burning heating :or appliances or an attached garage:_ They shall be installed in accordance with.the F.B.C. 21. All plumbing, mechanical,:and:electrical shall be separate from unit to:unit: This includes all. underground plumbingand electric: 22. All 2016:N:E:C: Codes:will be enforced:. 23:Tamper=Resistant Receptacles in accordance with 06.11-of the 2016 N.E:C 24::Iri accordance.With the Land:Development:Code,lots shall be sodded before final at least 10 feet around..the structure. 25. Blower door:test and blown in insulation-card shall be provided before C:.O: -26 A copy ofthe energy cads shall be with pernzit-at.all times. 2T.-Copy of final insulation report shall be:provided:avitlz.periiiit befoie rinaL F.F.E.-Finished Floor Elevation F.B.0 Florida'Building Code 6t'Edition. R.O.W.-Right of-Way :. A.D.A.-Americans with.Disabilities Act N.E.C.-National Electric Code(2011.) PLOT PLAN DESCRIPTION:(AS FURNISHED) LOT 12, BLOCK 6, SILVERADO RANCH SUBDIVISION PHASE 6, 8 & 9A AS RECORDED IN PLAT BOOK 75, PAGE(S) 75-79, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. PC I LOT 11 I3 BLOCK 6 Z F-a I GRAPHIC SCALE W OIL I $ o� o I 0 15 30 fr=3 I S87-24'281PE 110.00' Jtra I p I cd T`! Qom Q 24.5' •— — — _ cd 33.r -46.8' Eo O:'� lu' ( o qq o � N �O *W I V7 a s Qv I oI4'e o _. . z F JO oz �y U� m Ca I QD A. 40.67' a 2 22.5'.`,.., _ 40.7' oI 04 a -- --- m i-- oil 0 N 58724.28.E 30.00, 'r N87-24'280oW �� 110.00' .o 0 c4 LOT 13 \ PT BLOCK 6 \ ON LOT CALCULATIONS LOT = 6.050 SO. FT. LIVING AREA = 1.019 SO. FT. GARAGE = 432 SO. FT. ENTRY = 87 SQ. FT. LANAI = 0 SQ' FT. PATIO = 80 SQ. FT. DRIVEWAY = 360 SQ. FT. A/C PAD = 12 SQ. FT. WALKWAY = 31 SO. FT. IMPERVIOUS = 33% = 2021 SQ. FT. SOD = 4,029 SO. FT. OFF LOT CALCULATIONS PREPARED FOR: RIGHT of WAY = 990 SO. FT. DRIVE APRON = 247 SO. FT. HOMNI 468 PUBLIC S/W = S . FT. SOD = 468 SO. FT. J s TOTALS AREA = 7,040 SQ. FT. BUILDING SETBACKS DRIVEWAY = 607 SQ. FT. SIDEWALK = 306 SQ. FT. FRONT: 22' SOD = 4,497 SQ. FT. REAR: 15' SIDE: 7.5' SIDE STREET: 20' LEGEND: NOTES: —•—"— BUILDING SETBACK LINE PI POINT OF INTERSECTION PC POINT OF CURVATURE 1. ELEVATIONS SHOWN ARE PER LOT GRADING ——— CENTERLINE PT POINT OF TANGENCY PLANS PROVIDED BY THE CLIENT. —--— RIGHT OF WAY LINE RP RADIUS POINT 2. ELEVATIONS ARE BASED ON NAVD 1988 XDc PRC POINT OF REVERSE CURVATURE DATUM. PROPOSED ELEVATION PCC POINT OF COMPOUND CURVATURE TYP TYPICAL PROPOSED DRAINAGE FLOW CS CONCRETE SLAB THIS PLOT PLAN IS INTENDED FOR PERMITTING PURPOSES 0 CONCRETE cA�LcuL�'AiED ONLY. THIS IS NOT INTENDED FOR THE CONSTRUCTION OF (C PLAT BOOK THE PROPOSED HOUSE. REFER TO HOUSE PLAN AND A/C AIR CONDITIONER PCs PACES OPTION LIST FOR CONSTRUCTION. ALL BUILDING SET BACK S/W SIDEWALK SO. Fr. SQUARE FEET LINES SHOWN HEREON IS PER DATA FURNISHED BY CLIENT F.E.M.A. FEDERAL EMERGENCY MANAGEMENT AGENCY AND IS FOR INFORMATIONAL PURPOSES ONLY. F.I.R.M. FLOOD INSURANCE RATE MAP NAVD NORTH AMERICAN VERTICAL DATUM THIS IS NOT A SURVEY o&UE DRAINAGE GEODETIC EASEMENT THIS . THIS IS A PLOT PLAN ONLY UE PRIVATE TASEMEANT(PUBUC)T FLOW N®fi€i SURVEYOR NOTES: I HAVE EXAMINED THE F.I.R.M. MAP NO. 12101CO288F, 1. THE SURVEYOR HAS NOT ABSTRACTED THE DATED SEPTEMBER 26. 2014. AND FOUND THE SUBJECT PROPERTY LAND SHOWN HEREON FOR EASEMENTS, RIGHT APPEARS TO LIE IN ZONE-X-.AREAS DETERMINED TO BE OUTSIDE THE OF WAY, RESTRICTIONS OF RECORD WHICH 0.2%ANNUAL CHANCE FLOODPLAIN. THE SURVEYOR MAKES NO MAY AFFECT THE TITLE OR USE OF THE LAND. GUARANTEES AS TO THE ABOVE INFORMATION.PLEASE CONTACT THE LOCAL F.E.M.A. AGENT FOR VERIFICATION. 2. NO UNDERGROUND IMPROVEMENTS HAVE BEEN LOCATED EXCEPT AS SHOWN. BEARING BASIS: BEARINGS SHOWN HEREON ARE BASED ON THE CENTERLINE OF WAGON A5hA 3. NOT VALID WITHOUT THE AUTHENTIC TRAIL STREET BONG N0235'32'E,PER PLAT ELECTRONIC SIGNATURE AND THE AUTHENTIC ELECTRONIC SEAL OF A FLORIDA LICENSED REVISED: A M E FR I CAN SURVEYOR AND MAPPER. (FIELD DATE:) SURVEYING .spro° � � Digitally signed by James SCALE: f 30 FEET Q� d;.....,e Boleman <JC MAPPING INC. •�`°°"°`m{c y g DN:cn=James W Boleman, APPROVED BY: JB h2 -American Surveying&Mapping, CERTIFICATION OF AUTHORIZATION NUMBER LB#6393 .h& "-ou, 3191 MAGUIRE BOULEVARD, SUITE 200 '- t'"" email=jboleman@asmmrporate.co FOR 171013 LOT 12, BLK 6 ��0 nnn.;� Date:2017.12.1214:0354-05'00' FIRM Joe No. THE ORLANDO, FLORIDA 32803 (407) 426-7979 DRAWN BY: DSB PLOT PLAN 11 10 17 KJW WWWAMERICANSURVEYINGANDMAPPING.COM JAMES W. BOLEMAN PSM# 6485 DATE ,6 PASCO COUNT, FLORIDA Permit No. L t 7 2' Date Permitted Builder Name/Owner Name Control#' 'ter County Parcel No. 05-2(a - 11-0(6O-DO(�o_lbj SubDiv: Ve"dW Address/Location (�O S 74 t!L _((2 t 3 - Classification/Type of Use . fe tG� TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: Exempt ❑Yes ❑ No How Determined Impact Fee Amount $. 3( 00 Zone No. TAZ: SCHOOL IMPACT FEE Account (056) Single-Family Detached House Amount $ _ { a�7 ii. ?. (057) Mobile Home (058) Other Residential 123) Collection Fee Exempt [ Yes ❑ No How Determined PARKS AND RECREATION FEE Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation Total Zone TOTAL AMOUNT $ -7�l 51v Exempt ❑Yes ❑ No How Determined LIBRARY FEE Land Account Land Credit Land Total Facility Account Facility Credit Facility Total Exempt ❑ Yes ❑ No How Determined Total Amount RESOURCE FEE ERU TOTAL AMOUNT Prepared By ` Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE OF PASCO COUNTY Acknowledgement below does not Imply acceptance of concurrence,but simply receipt of a copy of this form,placing the building permit owner on notice of this assessment and the conditions of payment for same. DATE RECEIVED BY RECEIPT NO. DATE BY FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Galen 2432 Elev D Builder Name: D H Express Hoknes Street: L/ Permit Office: C"Yy'up&,,�Wts City,State,Zip: Zephyrhills,FL, _5q Permit Number: 1 W I Z' Owner: Jurisdiction: & 1(&00 Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2 1. New construction or existing New(From Plans) 9. Wall Types(2511.6 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=1 1.0 1269.30 ft2 b.Concrete Block-Int Insul,Exterior R=4.1 956.22 ft2 3. Number of units,if multiple fa I mily 1 c.Frame-Wood,Adjacent R=1 1.0 286.00 ft2 4. Number of-Bedrooms 4 d.N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types (1451.0 sqft.) Insulation - Area a.Under Attic(Vented) R=30.0 1451.00 ft2 6. Conditioned floor area above grade(ft2) 2432 b.N/A R= ft2 N/A Conditioned floor area below grade(ft2) 0 C.11.Duct R= ft2 s R ft2 7. Windows(229.0 sqft,) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 231 a. U-Factor: Dbl,U=0.34 189.00 ft2 SHGC: SHGC=0.31 b. U-Factor: DIJI,U=0.55 40.00 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.34 a.Central Unit 33.8 SEER:14.00 c. U-Factor: - N/A ft2 SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 33.8 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 1.585 ft. Area Weighted Average SHGC: 0.315 14.Hot water systems 8. Floor Types (1451.0 sqft.) Insulation Area a.Electric Cap:50 gallons a.Slab-On-Grade Edge Insulation R=O.O 1019.00 ft2 b. Conservation features EF:0.950 b.Floor over Garage R=19.0 432.00 ft2 None - c.N/A - R= ft2 15.Credits Pstat Glass/Floor Area: 0.094 Total Proposed Modified Loads: 74.13 PASS Total Baseline Loads: 74.48 I hereby certify that the plans and specifications covered by Review of the plans and '0*V14E S7, this calculation are in compliance with the Florida Energy specifications covered by this 0 Code. calculation indicates compliance with the Florida Energy Code. PREPARED BY: Before construction is completed DATE: 17 this building will be inspected for _,,I compliance with Section 553.908 .1 hereby certify that this building,as designed,is in compliance Florida Statutes. with the Florida Energy Code. OWNER/AGENT• BUILDING OFFICIAL: 1111�7/0- DATE:. ore-III I DATE: - Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. - Compliance with a proposed duct leakage On requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with Section 803 of RESINIET Standards,Is not greater than 0.060 On for whole house. 11/8/2017 4:41 PM EnergyGauge@ USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Galen 2432 Elev D C✓.i Builder Name: DRH Express Homes .Street: �yj5 �(t(�(��rC�� I J I ^ Permit Office, City,State,Zip: Zephyrhills, FL, 1 ��/ Permit Number: Owner: 7_ / 1Z Jurisdiction: Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(2511.6 sgft.) Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood, Exterior R=11.0 1269.30 ftz b.Concrete Block-Int Insul,Exterior R=4.1 956.22 ftz 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 286.00 ftz 4. Number of Bedrooms 4 d.N/A R= ftz 10.Ceiling Types (1451.0 sgft.) Insulation Area 5.. is this a worst case? No a.Under Attic(Vented) R=30.0 1451.00 ftz 6. Conditioned floor area above grade(ft2) 2432 b.N/A R= ftz Conditioned floor area below grade(ftz) 0 c.N/A R= ftz 11. Ducts R ftz 7. Windows(229.0 sgft.) Description Area a.Sup:Attic,Rot:2nd Floor,AH:2nd Floor 6 231 a. U-Factor: Dbl,U=0.34 189.00 ftz SHGC: SHGC=0.31 b. U-Factor: Dbl, U=0.55 40.00 ftz 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.34 a.Central Unit 33.8 SEER:14.00 c. U-Factor: - N/A ftz SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ftz a. Electric Heat Pump 3 .8 HSIF2.2Q SHGC: Area Weighted Average Overhang Depth: 1.585 ft. Area Weighted Average SHGC: 0.315 14.Hot water systems 8. Floor Types (1451.0 sgft.) Insulation Area a. Electric Cap:50 gallons a.Slab-On-Grade Ede Insulation R=0.0 1019.00 ftz EF:0.950 g b. Conservation features b. Floor over Garage R=19.0 432.00 ftz None c.N/A R= ftz 15.Credits Pstat PASS Glass/Floor Area: 0:094 Total Proposed Modified Loads: 74.13 f1 Total Baseline Loads: 74.48 I hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this a p Code. calculation indicates compliance4+ with the Florida Energy Code. PREPARED BY: Before construction is completed DATE: this building will be inspected for compliance with Section 553.908 n . I hereby certify that this building,as designed, is in compliance Florida Statutes. with the Florida Energy Code. G'C3D WE OWNER/AGENT BUILDING OFFICIAL: DATE: - DATE: _ -~ - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test.report in accordance with R402.4.1.2. - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with Section 803 of RESNET Standards, is not greater than 0.060 Qn for whole house. 1 1/8/201 7 4:41 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 1 FORM R405-2014 PROJECT Title: Galen 2432 Elev D Bedrooms::-: 4 ; Address Type: Lot Information Building Type: User Conditioned Area: 2432 Lot# 12/6 Owner: Total Stories: 2 Block/SubDivision: Silverado Ranch #of Units: 1 Worst Case: No : PlatBook: Builder Name: DRH Express Homes Rotate Angle: 270 Street: Permit Office: Cross Ventilation: County: Pasco Jurisdiction: Whole House Fan: City,State,Zip: Zephyrhills, Family Type: Single-family FL, New/Existing: New(From Plans) Comment: Garage R Face W CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp v Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Tampa FL_TAMPA_INTERNATI 2 39 91 70 75 645.5 54 Medium BLOCKS Number Name Area Volume 1 Blockl 2432 20138.7 SPACES Number Name Area Volume Kitchen ..Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 1019 8834.7 Yes 0 0 1 Yes Yes Yes 2 2nd Floor 1413 11304 No 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio Main 144.6 ft 0 1019 ftz ---- 0.5 0 0.5 2 Floor over Garage 2nd Floor ---- ---- 432 ftz 19 0.5 0 0.5 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1623 ftz 0 ftz Dark 0.92 No 0.9 No 0 26.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Vented 300 1451 ftz Y N 1 1/8/201 7 4:41 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2014 CEILING y # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) Main 30 Blown 38 ft2 0.11 Wood 2 Under Attic(Vented) 2nd Floor 30 Blown 1413 ft2 0.11 Wood WALLS Adjacent y Space avity Width Height Sheathing Framing Solar Below nrot Tn Wall Type C R-Vallle FL-Value Ft In Ft In Arp:; F:rnrt AhSor G rarfi-% I N=>W E)fterior, ,Concrete Block-Int Insul Main 4.1 18 8 8 156.0 W 0 0.6 0 2 W=>S Exterior Concrete Block-Int Insul Main 4.1 20 8 8 173.3 ft2 0 0.6 0 3 S=>E Exterior Concrete Block-Int Insul Main 4.1 38 8 8 8 335.1 ft2 0 0.6 0 4 E=>N Exterior Concrete Block-Int Insul Main 4.1 33 8 8 8 291.8 ft2 0 0.6 0 5 N=>W Garage Frame-Wood Main 11 20 0 8 8 173.3 ft2 0.23 0.01 0 6 W=>S Garage Frame-Wood Main 11 13 0 8 8 112.7 ft2 0.23 0.01 0 7 N=>W Exterior Frame-Wood 2nd Floor 11 38 8 8 309.3 W 0.23 0.6 0 8 W=>S Exterior Frame-Wood 2nd Floor 11 40 8 8 325.3 ft2 0.23 0.6 0 9 S=>E Exterior Frame-Wood 2nd Floor 11 38 8 8 309.3 ft? 0.23 0.6 0 10 E=>N Exterior Frame-Wood 2nd Floor 11 40 8 , 8 325.3 W 0.23 0.6 0 DOORS V # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N=>W Insulated Main None .4 3 6 8 20 ft2 2 E=>N Wood Main None .46 2 8 6 8 17.8 ft2 WINDOWS Orientation shown is the entered orientation(=>)changed to As Built(rotated 270 degrees). Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N=>W I Vinyl Low-E Double Yes 0.34. 0.31 31.0 ft2 5 ft 0 in 0 ft 4 in Drapes/blinds None 2 N=>W 1 Vinyl Low-E Double Yes 0.34 0.31 2.5 ft2 5 ft 0 in 0 ft 0 in Drapes/blinds None 3 W=>S 2 Vinyl Low-E Double Yes 0.34 0.31 15.5 ft2 1 ft 0 in 10 It 1 in Drapes/blinds None 4 S=>E 3 Vinyl Low-E Double Yes 0.34 0.31 46.5 ft2 1 ft 0 in 10 ft 1 in Drapes/blinds None 5 S=>E 3 Metal Low-E Double Yes 0.55 034 40.0 ft2 I ft0in 10ft9in Drapes/blinds None 6 N=>W 7 Vinyl Low-E Double Yes 0.34 0.31 16.0 ft2 1 ft 0 in 0 ft 3 in Drapes/blinds None 7 N=>W 7 Vinyl Low-E Double Yes 0.34 0.31 31.0 ft2 1 ft 0 in 3 ft 9 in Drapes/blinds None 8 S=>E 9 Vinyl Low-E Double Yes 0.34 0.31 46.5 ft2 1 ft 0 in 0 ft 3 in Drapes/blinds None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 432.1458 ft2 432.1458 ft2 49 ft 8.67 ft 0 1 1/8/201 7 4:41 PM EnergyGauge@ USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2014 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000368 2349.5 128.99 242.58 .3401 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump None HSPF:8.2 33.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type . Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit None SEER:14 33.8 kBtu/hr 1014 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 50 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ft2 DUCTS / ----Supply---- ----Return---- Air CFM 25 CFM25 HVAC# �/ # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 231 ft2 2nd Floor 40 ft2 Proposed Qn 2nd Floor ---cfm 145.9 cfm 0.06 0.60 1 1 TEMPERATURES Programable Thermostat:Y. Ceiling Fans: Coolingr 1 Jan Feb f 1 Mar f 1 A r Ma rX�Jun r Jul rX�Au rX�Se r 1 Oct r 1 Nov r Dec Heatin [X]Jan f Feb l Mar r Apr f May [ ]Jun E Jul E ]Au [ ]Sep [ ]Oct [X]Nov [ Dec Venting [[[ ]]]Jan l ]]]Feb [[[[XXXX]]]]Mar [X]Apr [ May [[[ ]Jun Jul ]Aug [[[ ]Se [[[XXX]]]Oct [[[XXX]]]Nov [[[ ]]]Dec 1 1/8/201 7 4:41 PM EnergyGauge@ USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2014 Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 - Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating(WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 1 1/8/201 7 4:41 PM EnergyGauge@ USA-FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD - ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerformance Index,the more efficient the home. Zephyrhills, FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1269.30 ft2 b.Concrete Block-Int Insul,Exterior R=4.1 956.22 ft2 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 286.00 ft2 4. Number of Bedrooms 4 d.N/A R= ft2 10.Ceiling Types Insulation Area 5. Is this a worst case? No a.Under Attic(Vented) R=30.0 1451.00 ft2 6. Conditioned floor area(ft2) 2432 b.N/A R= ft2 c.N/A R= ft2 7. Windows" Description Area 2 a. U-Factor: Dbl,U=0.34 189.00 ft2 11• Ducts R ft a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 231 SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.55 40.00 ft2 SHGC: SHGC=0.34 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a.Central Unit 33.8 SEER:14.00 SHGC: d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 33.8 HSPF:8.20 Area Weighted Average Overhang Depth: 1.585 ft. Area Weighted Average SHGC: 0.315 8. Floor Types Insulation Area 14.Hot water systems Cap:50 gallons a.Slab-On-Grade Edge Insulation R=0.0 1019.00 ft2 a.Electric EF:0.95 b.Floor over Garage R=19.0 432.00 ft2 c.N/A R= ft2 b. Conservation features None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building E s" Construction through the above energy saving features which will be installed (or exceeded) -Es" in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. ......,... .. as Builder Si nature Date: g Address of New Home: ' City/FL Zip: SOD Wale�g *Note: This is not a Building Energy Rating. If your Index is below 70,your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3-of the Florida Building Code, Energy Conservation, if not DEFAULT. 1 1/8/201 7 4:41 PM EnergyGauge@ USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014' Florida Department of Business and Professional Regulations Residential Whole Building Performance and Prescriptive Methods ADDRESS: Permit Number: Zephyrhills,FL, MANDATORY REQUIREMENTS See individual code sections for full details. 401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy.Florida law [Section 553.9085,Florida Statues]requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix C. R402.4.Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.1 through R402.4.4. O R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.The sealing methods between dissimilar materials shall allow for differential expansion and contraction. • R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table 402.4.1.1,as applicable to the.method of construction. Where required by the code official,an approved third party shall inspect all components and verify compliance. • R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2,and 3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3.Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return-registers,if installed at the time of the test,shall be fully open. O R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers and outdoor combustion air. O R402.4.3 Fenestration air leakage.Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400 or AAMA/WDMA/CSA 101/I.S.2-/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. O R402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm(0.944 Us)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential.All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. ❑ R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. ❑ R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. ❑ R403.2.2 Sealing(Mandatory)AII ducts,air handlers,and filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post-construction or rough-in testing below. Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either an energy rater certified in accordance with Section 553.99, Florida Statutes,or as authorized by Florida Statutes,to be"substantially leak free"by either of the following: 1. Post-construction test:Total leakage shall be less than or equal to 4 cfm (113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure.All register boots shall be taped or otherwise sealed during the test. 2. Rough-in test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25Pa)across the system,including the manufacturer's air handler enclosure.All registers shall be taped or otherwise sealed during the test.If the air handler is not installed at the time of the test,total leakage shall be less than or equal to 3 cfm (85 Umin)per 100 square feet(9.29 m2)of conditioned floor area. Exceptions: 1. The total leakage test is not required for ducts and air handlers located entirely within the building envelope. 2. Duct testing is not mandatory for buildings complying by Section R405 of this code. 1 1/8/201 7 4:41 PM EnergyGaugeOO USA-FlaRes2014 -Section R405.4.1 Com Page 1 of 3 FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) ❑ R403.2.3 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. ❑ R403.3 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C) or below 55°F(13°C)shall be insulated to a minimum of R-3., R403.3.1 Protection of piping insulation. ❑ R403.4.1 Circulating hot water systems(Mandatory). Circulating hot water systems shall be provided with an automatic or readily accessible manual switch that can turn off the hot-water circulating pump when the system is not in use. ❑ R403.4.3 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 31/2 inches(89 mm)in the hot water distribution line and cold water line located as close as possible to the storage tank. ❑ R403.4.4 Water heater efficiencies(Mandatory). O R403.4.4.1 Storage water heater temperature controls • R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature setting range shall be from 100°F to 140°F(38°C to 601C). • R403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s) - of combustion types of service water heating systems to be turned off. O R403.4.4.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1. R403.4.4.2.1 Solar water heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors, and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol,Collectors in installed solar water heating systems should meet the following criteria: _ 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and 2. Be installed at an orientation within 45 degrees of true south. ❑ R403.5 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code, Residential or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. ❑ R403.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment. O R403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1.This code does not allow designer safety factors,provisions for future expansion or other factors which affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. • R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load,but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.6,or the closest available size.provided by the manufacturer's product lines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load. 11/8/2017 4:41 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Com Page 2 of 3 FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) O R403.6.1.1 Cooling equipment capacity.(continued) The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacture's expanded performance data shall be used to select cooling-only equipment.This selection shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower cfm provided by the expanded performance data, the design value for entering wet bulb temperature and the design value for entering dry bulb temperature. Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space. Exceptions: 1. Attached single-and multi-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida-registered engineer,in attached single-and multi-family units,the capacity of equipment may be sized in accordance with good design practice. O R403.6.1.2 Heating equipment capacity • R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section R403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load. • R403.6.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.6.1. • R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.6.1. O R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. ❑ R403.7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the Commercial Provisions in lieu of Section R403. ❑ R403.8 Snow melt system controls(Mandatory). Snow and ice-melting systems,supplied through energy service to the building,shall include automatic controls capable of shutting off the system when the pavement temperature is above 55°F,and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40oF. ❑ R403.9 Swimming pools,inground spas and portable spas(Mandatory). The energy requirements for residential pools and inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSI/APSP-15.The energy requirements for portable spas shall be in accordance with ANSI/APSP-14. O R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on-off switch that is mounted outside the heater to allow shutting off the heater without adjusting the thermostat setting. R403.9.1.1 Gas and oil-fired pool and spa heaters. All gas-and oil-fired pool and space heaters shall have a minimum thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013 when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights. R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. O R403.9.2 Time switches. Time switches or other control method that can automatically turn off and on heaters and pumps according to a preset schedule shall be installed on all heaters and pumps.Heaters,pumps and motors that have built in timers shall be deemed in compliance with this equipment. Exceptions: • 1. Where public health standards require 24-hour pump operations. 2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation. O R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Outdoor pools deriving over 70 percent of the energy for heating from site-recovered energy,such as a heat pump or solar energy source computed over an operating season. ❑ RR404.1 Lighting equipment(Mandatory). A minimum of 75 percent of the lamps.in permanently installed lighting fixtures shall be high-efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps. Exception: Low-voltage lighting shall not be required to utilize high-efficacy lamps. O R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights ❑ R405.2 Performance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R-6. O R405.2.1 Performance ONLY. Ceilings shall have minimum insulation of R-19.Where single assemby of the exposed deck and beam type or concrete deck roofs do not have sufficent space, R-10 is allowed. 11/8/2017 4:41 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Com Page 3 of 3 FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Galen 2432 Elev D Builder Name: DRH Express Homes Street: Permit Office: City,State,Zip: - Zephyrhills,FL, Permit Number: Owner: Jurisdiction: Design Location: FL,Tampa COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope._ Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/doorjambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations,and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily.conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated,and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. - Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 11/8/2017 4:41 PM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Envelope Leakage Test Report Prescriptive and Performance Method Project Name: Galen 2432 Elev D Builder Name: DRH Express Homes Street: Permit Office: City,State,Zip: Zephyrhills, FL, Permit Number: Design Location: FL,Tampa Jurisdiction: Cond.Floor Area:: 2432 sq.ft. Cond.Volume: 20139 cu ft. Envelope Leakage Test Results Leakage Characteristics Regression Data: C: n: R: CFM(50): Single or Multi Point Test Data Ems' HOUSE PRESSURE FLOW: 1 Pa cfm EgLA: 2 Pa cfm ACH: 3 Pa cfm ACH(50): 4 Pa cfm 5 Pa cfm SLA: 6 Pa cfm R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2,3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3.Interior doors,if installed at the time of the test,shall be open; 4.Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. hereby certify that the above envelope leakage Where required by the code official, � 'ttESTAT, performance results demonstrate compliance testing shall be conducted by an _IV with Florida Energy Code requirements in approved third party. A written accordance with Section R402.4.1.2. report of the results of the test shall be signed by the third party 4 conducting the test and provided to * n SIGNATURE: the code official. ADD WE �� PRINTED NAME: BUILDING OFFICIAL: DATE: - DATE: 1 1/8/201 7 4:41 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 Duct Leakage Test Report Performance Method FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Form R405 Duct Leakage Test Report Performance Method " Project Name: Galen 2432 Elev D Builder Name: DRH Express Homes Street: Permit Office: City,State,Zip: Zephyrhills, FL, Permit Number: Design Location: FL,Tampa Jurisdiction: Duct Test Time: Post Construction Duct Leakage Test Results CFM25 Duct Leakage Test Values Line System Outside Duct Leakage 1 System 1" cfm25(Out) 2 System 2 cfm25(Out) 3 System 3 cfm25(Out) 4 System 4 cfm25(Out) 5 Total House Sum lines 1-4 Duct System Divide by Leakage (Total Conditioned Floor Area) (Qn,Out) I certify the tested duct leakage to outside, Qn, is Duct tightness shall be verified by �o4E STgT not greater than the proposed duct leakage Qn 41 testing to Section 803 of the RESNET �,, �_ 0 specified on Form R405-2014. Standards by an energy rater certified in accordance with Section 553.99, Florida Statutes. SIGNATURE: lilt: PRINTED NAME: WE ��S DATE: BUILDING OFFICIAL: DATE: 1 1/8/201 7 4:42 PM EnergyGaugeO USA-FlaRes2014 -Section R405.4.1 Compliant S Page 1 of 1 Manual S Compliance Report Job: wrightsofto Date: Oct 07,2014 Entire House By: Progressive Air Systems, Inc 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 Pr6jebt Ird6rmation, For: DR Horton/Express Lot 12 Blk 6 Silverado Ranch, Zephyrhills, FL -:0601ing qqi•ma6t p Design Conditions Outdoor design DB: 91.2°F Sensible gain: 25583 Btuh Entering coil DB: 76.0°F Outdoor design WB: 77.1 OF Latent gain: 3250 Btuh Entering coil WB: 63.0°F Indoor design DB: 75.0°F Total gain: 28833 Btuh Indoor RH: 50% Estimated airflow: 1120 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB036****A+FB4CNP036 Actual airflow: 1120 cfm Sensible capacity: 26365 Btuh 103%of load Latent capacity: 4753 Btuh 146%of load Total capacity: 31118 Btuh 108%of load SHR: 85% • " • metit u Design Conditions Outdoor design DB: 40.0°F Heat loss: 22889 Btuh Entering coil DB: 69.5°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB036****A+FB4CNP036 Actual airflow: 1120 - cfm Output capacity: 30307 Btuh 132%of load Capacity balance: 30 OF Supplemental heat required: 0 Btuh. Economic balance: -99 OF Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: - 1120 cfm Output capacity: 7.5 kW 112%of load Temp. rise: 17 OF Meets are all requirements of ACCA Manual S. wrightsoft, Right-Suite@ Universal 2017 17.0.21 RSU25554 2017-Nov-08 16:43:34 Page 1 14C�C'A ...les\Express hornes\Galen 4EGB-3 ton New Code.rup Calc=MJ8 House faces: W Load Short Form Job. wrightsoft° Date: Oct 07,2014 Entire House By: Progressive Air Systems, Inc 5907 Dasher Ct,Port Richey,FL 34668 Phone:7277847-3898 Fax:727-815-3399 License:CAC033669 Project • • For: DR Horton/Express Lot 12 Blk 6 Silverado Ranch, Zephyrhills, FL 'Vesigh Informatioh, Htg Clg Infiltration Outside db(OF) 40 91 Method Simplified Inside db(OF) 70 75 Construction quality Semi-tight Design TD (OF) 30 16 Fireplaces 0 Daily range - L Inside humidity (%) 50 50 Moisture difference(gr/lb) 26 54 HEATING EQUIPMENT COOLING EQUIPMENT Make Carrier Make Carrier Trade CARRIER Trade CARRIER Model CH14NB036****A Cond CH14NB036****A AHRI ref Coil FB4CNP036 AHRI ref Efficiency 8 HSPF Efficiency 11.7 EER, 14 SEER Heating input Sensible cooling 25200 Btuh Heating output 34000 Btuh @ 470F Latent cooling 8400 Btuh Temperature rise 28 OF Total cooling 33600 Btuh Actual air flow 1120 cfm Actual air flow 1120 cfm Air flow factor 0.049 cfm/Btuh Air flow factor 0.044 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.89 Capacity balance point=30 OF Backup: Input=8 kW, Output=25681 Btuh, 100 AFUE ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft.) (Btuh) (Btuh) (cfm) (cfm) great/kitchen 628 8291 8125 406 356 pantry 42 582 188 28. 8 powder 33 6 9 0 0 flex 163 2707 2823 132 124 foyer 99 1503 1031 74 45 stairs 58 436 210 21 9 bed2 164 1437 1869 70 . 82 bed4 164 826 1439 40 63 bed3 175 1491 1916 73 84 chase 4 5 6 0 0 chase2 5 6 8 0 0 laundry 53 349 886 17 39 M bath 168 1512 1951 74 85 we 25 30 41 1 2 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wri htsoftc 2017-Nov-08 16:age 1 r' 9 Right-Suite®Universal 2017 17.0.21 RSU25554 Page 1 ACCA ...les\Express homes\Galen 4EGB-3 ton New Cocle.rup Calc=MA House faces: W a/c 17 20 28 1 1 M bed 308 2557 3968 125 174 chase 3 4 7 8 0 0 bath2 68 540 430 26 19 stairs2 39 47 64 2 3 hall 195 408 445 20 19 wic 70 129 139 6 6 Entire House d 2478 22889 25583 1120 1120 Other equip loads 0 0 Equip. @ 1.00 RSM 25583 Latent cooling 13250 TOTALS 2478 22889 28833 1120 1120 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 1 wrl htsofta 2017-Nov-0816:43:34 9 Right-Suite®Universal 2017 17.0.21 RSU25554 Page 2 ...les\Express homes\Galen 4EGB-3 ton New Code.rup Calc=MJ8 House faces: W ti ect Summar Pro Job: �- wrightsoft® � � Date: Oct 07,2014 Entire House By: Progressive Air Systems, Inc 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 __W'Pfoject Information For: DR Horton/Express Lot 12 Blk 6 Silverado Ranch, Zephyrhills, FL Notes: ..Desian Intbirmation Weather: Tampa Intl AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 40 OF Outside db 91 OF Inside db 70 OF Inside db 75 OF Design TD 30 OF Design TD 16 OF Daily range L Relative humidity 50 % Moisture difference 54 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 18093 Btuh Structure 19771 Btuh Ducts 4796 Btuh Ducts 5812 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 22889 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration. Equipment sensible load 25583 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 2371 Btuh Ducts 880 Btuh Central vent (0 cfm) 0 Btuh Heating Cooling (none) Area(ft2 2478 2478 Equipment latent load 3250 Btuh Volume(ft3) 20539 20539 Air changes/hour 0.22 0.11 Equipment total load 28833 Btuh Equiv.AVF(cfm) 75 38 Req. total capacity at 0.75 SHR 2.8 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER Trade CARRIER Model CH14NB036****A Cond CH14NB036***"A AHRI ref Coil FB4CNP036 AHRI ref Efficiency 8 HSPF Efficiency 11.7 EER, 14 SEER Heating input Sensible cooling 25200 Btuh Heating output 34000 Btuh @ 47°F Latent cooling 8400 Btuh Temperature rise 28 °F Total cooling 33600 Btuh Actual air flow 1120 cfm Actual air flow 1120 cfm. Air flow factor 0.049 cfm/Btuh Air flow factor 0.044 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.89 Capacity balance point=30 OF Backup: Input=8 kW, Output= 25681 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. WI'1 lItSOTt" 2017-Nov-0816:43:34 9 Right-Suite®Universal 2017 17.0.21 RSU25554 Page 1 ...les\Express homes\Galen 4EGB-3 ton New Code.rup Calc=MJ8 House faces: W FORM R4b5-2014 RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST Florida Department of Business and Professional Regulation Simulated Performance Alternative (Performance)Method Applications for compliance with the 2014 Florida Building Code, Energy Conservation via the residential Simulated Performance method shall include ❑ This checklist ❑ A Form R405 report that documents that the Proposed Design complies with Section R405.3 of the Florida Energy Code. This form shall include a summary page indicating home address, a-ratio and the pass or fail status along with summary areas and types of components, whether the home was simulated as a worst-case orientation, name and version of the compliance software tool, name of individual completing the compliance report(1 page)and an input summary checklist that can be used for field verification (usually 4 pages/may be greater). ❑ Energy Performance Level(EPL) Display Card(one page) ❑ Mandatory Requirements(three pages) Required prior to CO for the Performance Method: ❑ Air Barrier and Insulation Inspection Component Criteria checklist(Table R402.4.1.1 - one page) ❑ A completed Envelope Leakage Test Report(usually one page) ❑ If Form R405 duct leakage type indicates anything other than "default leakage", then a completed Form R405 Duct Leakage Test Report(usually one page) EnergyGauge®-USRCZB v5.1 1 1/9/201 7 8:54:30 AM - Page 1 of 1 d CITY OF " NOTICE " / / BUILDING ZEPHYRHILLS DEPARTMENT OF ADDITION OR CORRECTION D • NOT - • ADDRESS DATE PERMIT f /0117C74 "m -1fv,L 'LL 129 1 THIS JOB HAS NOT BEEN COMPLETED. The following additions or corrections shall be made before the job will be accepted. ' ©ua*J Zq,,.s-E ef /tc It is unlawful for any Carpenter,Contractor,Builder,or other persons,to AFTER CORRECTIONS ARE MADE CALL cover or cause to be covered,any part of the work with flooring,lath,earth 780-0020 FOR R -INSPECTION or other material,until the proper inspector has had ample time to approve the installation. OFFICE HOURS 7:30AM-4:30 PM MON.-FRI. INSPECTOR CITY OF / / / / BUILDING ZEPHYRHILLSNOTICE DEPARTMENT OF ADDITION OR CORRECTION DO NOT REMOVE ADDRESS DATE PERMIT¢ ? /- 1 Z- j The following additions or corrections shall be made before the job THIS JOB HAS NOT BEEN COMPLETED. will be accepted. Ifio vt�kL -r'T' 0 nw, 1 It is unlawful for any Carpenter,Contractor,Builder,or other persons,to AFTER CORRECTIONS ARE MADE CALL cover or cause to be covered,any part of the work with flooring,lath,earth or other material,until the proper inspector has had ample time to approve 780-0020 FOR RE-INSPECTION the installation. i OFFICE HOURS 7:30AM-4:30 PM MON.,FRI. INSPECTOR i PASCO COUNTY ' A 1 � C ,� DEVELOPMENT SERVICES 1 8731 Citizens Drive Date: 12/27/2018 COUNTY FLORIDA New Port Richey, FL 34654 OPEN SPACES.VIBRANT PLACES. 727-847-2411 ** NOT A PERMIT ** Receipt#: 1818951 FEE DESCRIPTION ACCOUNT CODE UNITS INVOICE# FEE AMOUNT PAID RECEIPT# DATE Impact Fee Residential Solid 24503100-329010 0.85 1414285 $0.85 $0.85 1818951 12/27/18 Waste Single Family TOTALS: $0.85 $0.86 Receipt# Paid By Check# CC Auth# Cashier ID Workstation Receipt Date Amt Paid 1818951 Cash 555 BCCCP35W 12/27/2018 $0.85 Total Payments: $0.86 Pavor Address Phone Michelle Moyes, D R Horton 6574 Wagon Trail St. 813-549-1968 Zephyrhills FL Comments: solid waste#19972 city of Zephyrhills 6574 Wagon Trail St. Zephyrhills FL While you will be paying your bill with Pasco County Development Services,the full amount of the credit card or a-check fees,NOT shown above,is collected by First Billing payment services. MyReports/reports//PASCOPROD/PASCO/ReceiptPOS V6.rpt 12/27/2018 Page 1 of 1 5335 - 8TH STREET (813)780-0020 CERTIFICATE OF OCCUPANCY Address: 6574 WAGON TRAIL ST Owner: DR HORTON INC ZEPHYRHILLS, FL. 12602 TELECOM DR Subdiv: SILVERADO TEMPLE TERRACE FL 33637-0935 Parcel: 05-26-21-0080-00600-0120 Work Type: 101-NEW CONST/SFR Construction Type: NOT APPLICABLE ❑ Sprinklers Use Classification: NOT APPLICABLE Permit Number: 19972 Date: 12/27/2018 w&. 0:2��� ISSUE Y: BUILDI OFFICIAL : WATER MUST BE CHANGED OVER WITHIN 10 DAYS OF ISSUANCE GARBAGE DEPOSIT MUST BE APPLIED FOR PRIOR TO ISSUANCE