Loading...
HomeMy WebLinkAbout18-19974 CITY OF ZEPHYRHILLS 5335-8TH STREET (813)780-0020 19974 BUILDING PERMIT SINGLE FAMILY RESIDENTIAL PERMIT INFORMATION -= LOCATION INFORMATION Permit#:19974 Issued: 7/30/2018 Address: 6525 WAGON TRAIL ST Permit Type: NEW SINGLE FAMILY DWELLING ZEPHYRHILLS, FL. Class of Work: 101-NEW CONST/SFR Township: Range: Proposed Use: NOT APPLICABLE Lot(s): Block: Section: Sq. Feet: Est. Value: Book: Page: Cost: 353,157.75 Total Fees: 11,776.70 Subdivision: SILVERADO Amount Paid: 11,776.70 Date Paid: 7/30/2018 Parcel Number: 05-26-21-0080-00600-0220 ' CONTRACTOR INFORMATION OWNER INFORMATION Name: DR HORTON INC Name: DR HORTON INC Addr: 12602 TELECOM DR Address: 12602 TELECOM DR TAMPA, FL. 33637 TEMPLE TERRACE FL 33637-0935 Phone: Lic: Phone: 813-549-1968 Work Desc: CONSTRUCT SINGLE FAMILY 3,135 SQ FT APPLICATION FEES BUILDING FEE 1,346.94 ELECTRICAL FEE 280.58 PLUMBING FEE 187.05 MECHANICAL FEE 130.94 POLICE IMPACT FEE 254.00 FIRE IMPACT FEE 273.00 PUBLIC SAFETY 5% 26.35 PARK FEES SF 769.56 SCHOOL IMPACT FEE-sfr/100% 4,828.00 SCHOOL IMPACT FEE-sfr/1% 48.28 TRAFFIC IMPACT FEE 99% 3,595.68 TRAFFIC IMPACT FEE 1% 36.32 ct Ins 6 e tVons Required FOOTER 2ND ROUGH PLUMB MISC INSULATION CEILING FOOTER BOND DUCTS INSULATED SEWER MISC. ROUGH ELECTRIC LINTEL MISC MISC. 1ST ROUGH PLUMB PRE-METER INSULATION WALL MISC. DUCTS INSTALLED WATER MISC DRIVEWAY PRE-SLAB SHEATHING MISC. MISC. CONSTRUCTION POLE FRAME MISC. MISC. REINSPEC71ON FEES: (c)With respect to Reinspection fees will comply with Florida Statute 553.80 (2)(c)the local government shall impose a fee of four times the amount of the fee imposed for the initial inspection or first reinspection,whichever is greater,for each such subsequent reinspection.REINSPECTION FEES: NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management, state agencies or federal agencies. "Warning to owner: Your failure to record a notice of commencement may result in your paying twice for improvements to your property. If you intend to obtain financing,consult with your lender or an attorney before recording your notice of commencement." Complete Plans,Specifications and Must Accompany Application. All work shall be performed in accordance with City Codes and Ordinances. NO OCCUPANCY BEFORE C.O. NO OCCUPANCY BEFORE C.O. CONTRACTORS SIGNATURE PERMIT OFFI PERMIT EXPIRES IN 6 MONTHS WITHOUT APPROVED INSPECTIO CALL FOR INSPECTION - 8 HOUR NOTICE REQUIRED PROTECT CARD FROM WEATHER DR Horton-6525 Wagon Trail St-3,135 sq ft Column SQ. FEET PRICE MAIN OR LIVING: 3,135 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 353,157.75 FEE SHEET $ 1,247.00 ADDRESS $ 30.00 DRIVEWAY $ 45.00 BUILDING: $ 1,346.94 ELECTRICAL: $ 280.58 PLUMBING: $ 187.05 MECHANICAL: $ 130.94 SUB-TOTAL $ 1,945.50 TOTAL $ 1,945.50 SEWER: n/a WATER: n/a IRRIGATION: $ - TOTAL: $ - WATER METER: n/a IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 2,498.85 PARK IMPACT FEES $ 769.56 SIF'S: $ 4,828.00 100.0% $ 4,828.00 1.0% $ 48.28 TOTAL: $ 4,876.28 T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 11,776.69 I_LU--flu City of Zephyrhills BUILDING PLAN REVIEW COMMENTS Contractor/Homeowner: Date Received: n f k Site: ,� W� 17RAI r f Permit Type: L Approved w/no comments:❑ Approved w/the below comments: Denied w/the below comments: ❑ S7& This comment sheet shall be kept with the permit and/or plans. 0 Kalvin SwitPPlans Examiner Date Contractor and/or Homeowner (Required when comments are present) INSTR#2.018099755OR BK9740 PG2172 Page lofi 06113/2018 11:22 AM Rcpt: 1965391 Rec:10.00 DS:0.00 IT:0.00 Paula S. O'XeiC Ph.D, Pasco County Clerk&Comptrotler Permit No. Parcel'ID No 4 K0 -Ont060-P-2Zn NOTICE OF COMMENCEMENT State of Florida County of Pasco THE UNDERSIGNED hereby gives notice that improvement will be made to certain real property,and in accordance with Chapter 713,Florida Statutes, the following information is provided in this Notice of Commencemen 1. Description of Property: Parcel Identification No. Z:_1K FrinY-1 0 (Q,I Lt�-r , Street Address: �Qjc52_15 V�ICA�—\PQ" I S-fc(�, 2. General Description of Improvement 1�ew Single Family Residence 3. Owner Information or Lessee information if the Lessee contracted for the improvement: D.R. Horton. Inc Name 12602 Tplarom Drive Tampa 33637 FI Address city State Interest in Property: FeeSiMple Name of Fee Simple Titleholder: (If different from Owner listed above) Address City State 4. Contractor -D.R.-Horton, Inc Name 126-02 Telecom Drive Tampa 33637 FL Address city State Contractor's Telephone No.: 5. surety: N/A Name Address city State Amount of Bond: $ N/A Telephone No.: 6. Lender. N/A Name Address city State Lender's Telephone No.: 7. Persons within the State of Florida designated by the owner upon whom notices or other documents may be served as provided by Section 713.13(1)(a)(7),Florida Statutes: David Guide Name 12602 Telecom Drive Tampa 33637 FL Address City State Telephone Number of Designated Person: 813-740-9720 8. In addition to himself,the owner designates N/A of to receive a copy of the Uenors Notice as provided in Section 713.13(1)(b),Florida Statutes. Telephone Number of Person or Entity Designated by Owner. 9. Expiration date of Notice of Commencement(the expiration date may not be before the completion of construction and final payment to the contractor,but will be one year from the date of recording unless a different date is specified): WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING,CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. Under penalty of perjury,I declare that I have read the foregoing notice of commencement and that the facts stated therein are true to the best of my knowledge and belief. STATE OF FLORIDA COUNTY OF PASCO rA,A Z29 Sigtuee—of Owner or Lessee,or Owner's or Lessee's Authorized 0 tr/Director/Partner/Manager -Assistant SecretaW 20L��y 't 4� Q D.R. Horton. Inc Signatory'sTitle/Office The foregoing instrument was acknowledged before me this;I—day of V1 yD a, _Oda as-Assistant Secretary —(type of awgrity,e.g.,officer,trustee,attorney in fact)for DR, Horton. Inc (name of party on b tf of whom was executed). Personally Known X OR Produced Identification 0 Notary Slgnatu�jii Type of Identification Produced Name(Print) Notary Public State of Florida MlOelte Mayes «� My Commission GG 057321 -10 Expires 1212112020 wpdatafbcs/noticecommencement_pc053048 COUNTY, FLORIDA Permit No. Date Permitted Builder Name/Owner Name t 7"S� Control County Parcel No. ©uo SubDIv: Address/Location � 52 I't)a� t1PAc cal " ' ClassiflcationlType of Use c5iny�e TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: 3,525 _ Exempt ❑Yes ❑ No How Determined .i Impact Fes Amount $,2j632.. O Zone No. TAZ: SCHOOL IMPACT FEE Account (056) Single-Family Detached House Amount $ (057) Mobile Home (058) Other Residential 123) Collection Fee Exempt Yes Q No How Determined PARKS AND RECREATION FEE' Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation Total ':- Zone TOTAL AMOUNT $ Exempt ❑Yes ❑ No How Determined. c:; l` LIBRARY FEE Land Account Land Credit Land Total Facility Account Facility Credit Facility Total Exempt ❑Yes ❑ No How Determined Total Amount RESOURCE FEE ERU TOTAL AMOUNT Prepared By 9 Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE-OF PASCO COUNTY Acknowledgement below does not Imply acceptance of concurrence,but simply receipt of•a copy of this form,placing the building permit owner.on notice of this assessment and the conditions of payment for same. DATE RECEIVED BY RECEIPT NO. DATE' BY D.R. Horton-,352rWagon Trail St:3,135 sq ft o umn Es SQ. FEET. PRICE MAIN OR LIVING: 3,135 $ 112.65 OTHER AREA UNDER ROOF: - $ 88.00 OTHER: - $ - VALUATION $ 353,157.75 FEE SHEET $ 1,250.00 ADDRESS $ 40.00 DRIVEWAYI $ 40.00 BUILDING: $ 1,355.00 ELECTRICAL: $ 281.25 PLUMBING: $ 187.50 MECHANICAL: $ 131.25 SUB-TOTAL $ 1,955.00 TOTAL $ 1,955.00 SEWER: n/a WATER: - n/a IRRIGATION: $ - TOTAL: $ - WATER METER: n/a IRRIGATION METER $ - FIRE DEPARTMENT FEES PLANS TOTAL: n/a INSPECTION TOTAL: PERMIT TOTAL TOTAL: $ - PUBLIC SAFETY IMPACT FEES POLICE $ 254.00 - FIRE $ 273.00 5% $ 26.35 TOTAL: $ 553.35 SUB-TOTAL $ 2,508.35 PARK IMPACT FEES $ 769.56 i SIF'S: $ 4,828.00 100.0% $ 4,828.00 1.0% $ 48.28 TOTAL: $ 4,876.28 I T I F'S: $ 3,632.00 99% $ 3,595.68 1% $ 36.32 TOTAL: $ 11,786.19 PASCO COUNTY, FLORIDA Permit No. Date Permitted — 6 Builder Name/Owner Name 4r4 Control#' ` County Parcel No. 5-Z& 2!—C 08b 00(qZ, D 22o SubDiv: 31 � - Address/Location Classification/Type of Use re TRANSPORTATION IMPACT FEE Rate: Sq.Ft Unit: Exempt ❑Yes ❑ No How Determined ;v Impact Fee Amount $.�r632-00 Zone No. TAZ: Gr` SCHOOL IMPACT FEE Account (056) Single-Famlly Detached House Amount $ (057) Mobile Home (058) Other Residential 123) Collection Fee Exempt �] Yes ❑No How Determined PARKS AND RECREATION FEE- Land Account Land Credit Land Total Recreation Account Recreation Credit Recreation Total Zone TOTAL AMOUNT Exempt ❑Yes ❑ No How Determined LIBRARY FEE Land Account Land Credit Land Total Facility Account Facility Credit Facility Total Exempt ❑ Yes ❑ No How Determined Total Amount/ RESOURCE FEE ERU TOTAL AMOUNT Prepared By Checked By NO CERTIFICATE OF OCCUPANCY WILL BE ISSUED OR FINAL INSPECTION PERFORMED UNTIL THE TOTAL AMOUNTS LISTED HAVE BEEN PAID AND RECEIPTED FOR BY A CENTRAL PERMITTING OFFICE-OF PASCO COUNTY �V _ Acknowledgement below does not imply acceptance of concurrence,but simply receipt of•a copy of this form,placing the building permit owner,on notice of this assessment and the conditions of payment for same. DATE RECEIVED BY RECEIPT NO. DATE BY 05-26-21-0080-00600-0220 1 Pasco County Property Appraiser Page 1 of 1 Data Current as Of: Weekly Archive - Saturday, July 14, 2018 Parcel ID 05-26-21-0080-00600-0220 (Card: 001 of 001) Classification 00 - Vacant Residential Mailing Address Property Value DR HORTON INC Ag Land $0 12602 TELECOM DR Land $2,443 TEMPLE TERRACE FL 33637-0935 Building $0 Physical Address Extra Features $0 6525 WAGON TRAIL STREET ZEPHYRHILLS, FL 33541 Just Value $2,443 Legal Description (First 4 Lines) Assessed (Non-School Amendment 1) $2,443 SILVERADO RANCH SUBDIVISION PHASES 6, 8 &9A PB 75 PG 075 BLOCK 6 Taxable Value $2,443 LOT 22 Jurisdiction City of Zephyrhills Land Detail (Card: 001 of 001) Line_M Use Descri_ptionioning Units _ yT pe jPrice condition Value Line j 0100 SFR MPUD 6,000.00 SF $0.40 10,0 $2,400 2 0- 100` SFR MPUD 170.00 SF j $0.25 1.00 $43 _ Additional La__nd_ Information Acres 0.14 Tax Area 30SI FEMA Residential Code i SLVRCPI - ---��._—._ Code ------ Building Information - Use 00 - Unimproved (Card: 001 of 001) Unimproved Parcel 00 - Unimproved Extra Features (Card: 001 of 001)__ Line -Description ear jUnitsValue No Extra Features Sales History- See All 6 sales Previous Owner: DUNE FL LAND I SUB LLC Month/YearjBook/Page J'-.-.--Type 'DOR Code ConditioniAmount 05/2018 19725 / 0407 Warranty Deed —� 05 Vacant Multi-Parcel Sale T05/2017 19535 / 0546 Certificate of Title 1 05 ( Vacant iMulti-Parcel Sale 11/2016 119462 / 0384 Mineral Rights or Royalty Transfer 05 Vacant Multi-Parcel Sale http://search.pascopa.com/parcel.aspx?parcel=2126050080006000220 7/18/2018 6'13-7e0-0020 City of Zephyrhil!s Permit Application Fax=813-780-0021 Building Department Date Received Phone Contact for Permitting - T"Tl-3T1-1 I " 1- (y Owner's Name c, s: Owner Phone Number Ci �� U Owner`s.Address p ` i Gs'1'!���� � Owner Phone Number Fee Simple Titleholder Name j s-t: Owner Phone Number FeeSimple Titleholder Address JOB ADDRESS - S - VCA ?36-q LOT# Z2 SUBDIVISION J F� 1�'L'-('"G C=4 G" PARCEL ID# (OBTAINED FROM PROPERTY TAX NOTICE) ' WORK PROPOSED NEW CONSTR R ADD/ALT SIGN DEMOLISH INSTALL REPAIR PROPOSED USE F-9— SFR COMM " ' .,� " . OTHER 1TYPE OF CONSTRUCTION , �� BLOCK F FRAME 0 STEEL \DESCRIPTION OF WORKrl eL J BUILDING SiZE �- SO FOOTAGE Lj 3 HEIGHT BUILDING $ VALUATION OF TOTAL CONSTRUCTION =ELECTRICAL $. AMP SERVICE 0 PROGRESS ENERGY 0 . W.R.E.C. =PLUMBING $ OMECHANICAL $ VALUATION OF MECHANICAL INSTALLATIONv �� Z GAS ROOFING Q SPECIALTY OTHER FINISHED FLOOR ELEVATIONS FLOOD ZONE AREA =YES NO •-b-C-i-1-I--1 -i-1- '-F-4-4-•G- -G-1--1- -G-•0-9-i-y--1--1- -W F-Ir�1-I-4-4-'i�:••;r•G-i a o-ll ; ".74 1l-ll r•p-1-a-1 BUILDER ;„/ COMPANYr` - -� c1 `'�-c� '� 2-1"f' C SIGNATURE REGISTERED Y/ N FEE CURREN Y(N Address Jc �c7�, J� I c-cin.� r^ J��a� �- t�Eo5�t� (v License# .ELECTRICIAN -�It . COMPANY �1? SIGNATURE REGISTERED Y/ N FEE CURREN Y/N Address �"tf '� .:�* License# d� % � PLUMBER COMPANY /0,2"/�` C1 SIGNATURE-~ REGISTERED Y( N FEE CURREN Y/N i Address ,1 'F ?, , ` License# a rc ow-2� MECHANICAL COMPANY �ll( G* �dJ �� • " SIGNATURE f `""G/` _-_----REGISTERED Y// N FEE CURREN Y/N Address . ,F:f /,�G.x` � f3�Ca��'�lriGr f'`1`cr ,,��- � License# �4��,;>,5 fi06 OTHER , COMPANY L/It i .�''/�/7I.'•./' s7)i'- SIGNATURE tREGISTERED Y/ N FEE CURREN Y/N Address tl t� �!f j License# iitilllllllililil11111111111l11l111111111i1i1t1lIt .11tltlil ! llii1111 RESIDENTIAL Attach (2) Plot Plans;(2)sets of Building Plans; (1)set of Energy Forms; R-O-W Permit for new construction, Minimum ten(10)working days after submittal date. Required onsite,Construction Plans,Stormwater Plans w/Silt,Fence installed, Sanitary Facilities&1 dumpster;Site Work'Permit for subdivisions/large projects COMMERCIAL Attach(2)complete sets Of Building Plans plus a Life Safety Page; (1)set of Energy Forms.R-b-W Permit for new construction. Minimum ten (10)working days after submittal date. Required onsite, Construction Plans,Stormwater Plans w/Silt Fence installed, Sa itary Facilities&1 dumpster.Site Work Permit for all new projects.Ali commercial requirements must meet compliance SIGN PERMIT A ch(2)sets of Engineered Plans. PROPERTY•SURVEY required for all NEW construction. Directions: o ns:.i--A--A-Directions: ' Fill out application completely. Owner 4 Contractor sign back of application,notarized If over$2500,a Notice of Commencement is required. (A/C upgrades over$75o0) "* Agent(for the contractor)or Power of Attorney(for the owner)would be someone with notarized letter from owner authorizing same OVER THE COUNTER PERMITTING (copy of contract required) . Reroofs if shingles - Sewers Service Upgrades A/C Fences(Plot/Survey/Footage) Driveways-Not over Counter if on public roadways..needs ROW PLOT PLAN DESCRIPTION:(AS FURNISHED) " LOT 22, BLOCK 6, SILVERADO RANCH SUBDIVISION PHASE 6, 8 & 9A AS RECORDED IN PLAT BOOK 75, PAGE(S) .75-80, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. - Curve Table PC Curve# Length Radius Delta Chord Bearing Chord .C1 11.01' 50.00' 1216'48' N4716'58"W 10.98' C2 12.58' 25.00' 28.49'44" N40.46'0a"W 12.45' R�y'I'�� lO�`'t'F rRPFF Line Table ,y'PP.yC Line # Direction Length - . \S`�3;GAF• L1 M55'1VOD'W 17.10' 2\�yRi1,CJ T�pq�,gCO \\ �/L,gTFs0 Zpo o,�ysT'I'F 1" = 30 GRAPHIC SCALE \ 9y 0 15 30 s\ ' 105.79zo 0. r I o ZO Jm \ o OP4j�9 S CL F ON LOT CALCULATIONS (0 LOT = 6,169 SQ. FT. ,7 n8y A� LIVING AREA = 1.104 SQ. FT. ENTRY GARAGE = 115 SQ. FT. LANAI = 0 SQ. FT. PATIO = 80 SQ. FT.. DRIVEWAY = 395 SQ. FT. C3 105.1 A/C PAD = 12 SQ. FT. �yC� t9 WALKWAY = 30 SO. FT. 9P�pc9�� to j IMPERVIOUS = 25 3 SQ. FT. PREPARED FOR: 6'•� Yl SOD = 3,996 SQ. FT. 105.9 OFF LOT CALCULATIONS v D_-R•HORTON.` per,. 9�01 \ DRIVE RIGHT OF WAY = SQ. FT. 'APRON = 242 242 SQ. FT. JFgGf!1CCi�S. Lf3G ' \ PUBLIC S/W = 280 SQ. FT. SOD = 355 SQ. FT. .BUILDING SETBACKS `� F(O00 AREALS 7,046 SO. FT. FRONT: 22' \� l° 2OIF, DRIVEWAY = 637 SQ. FT. REAR: 15' \� 60, SIDEWALK = 310 SQ. FT. SIDE: 7.5' Fv°IF SOD = 4,351 SQ. FT. SIDE STREET: 20' LEGEND: NOTES: — BUILDING SETBACK LINE PI POINT OF INTERSECTION - PC POINT OF CURVATURE 1. ELEVATIONS SHOWN ARE PER LOT GRADING — CENTERLINE PT POINT OF TANGENCY PLANS PROVIDED BY THE CLIENT.- —— — — RIGHT OF WAY LINE RP RADIUS POINT 2. ELEVATIONS ARE BASED ON NAVD 1988 XX PRC POINT OF REVERSE CURVATURE' DATUM. - � PROPOSED ELEVATION PCC POINT OF COMPOUND CURVATURE TYP TYPICAL PROPOSED DRAINAGE FLOW GS CONCRETE SLAB THIS PLOT PLAN IS INTENDED FOR PERMITTING PURPOSES CONCRETE (P) PER PLAT (C) CALCULATED ONLY. THIS IS NOT INTENDED FOR THE CONSTRUCTION OF p8 PLAT BOOK THE PROPOSED HOUSE. REFER TO HOUSE PLAN AND A/C AIR CONDITIONER PBS PAGES OPTION LIST FOR CONSTRUCTION. ALL BUILDING SET BACK S/W SIDEWALK SO. FT. SQUARE FEET LINES SHOWN HEREON IS PER.DATA FURNISHED BY CLIENT F.E.M.A. FEDERAL EMERGENCY MANAGEMENT AGENCY AND IS FOR INFORMATIONAL PURPOSES ONLY. F.I.R.M. FLOOD INSURANCE RATE MAP NAVD NORTH AMERICAN VERTICAL DATUM NGVD NATIONAL GEODETIC VERTICAL DATUM THIS IS NOT A SURVEY D&UE DRAINAGE& UTILITY EASEMENT E PRIVATE THIS IS A PLOT PLAN ONLY UE UTILITY EASEMENT(PUBLIC)EASEMENT FLOOD NOTE: SURVEYOR NOTES: I HAVE EXAMINED THE F.I.R.M. MAP NO. 12101CO26BF; 1. THE SURVEYOR HAS NOT ABSTRACTED THE DATED SEPTEMBER 26. 2014, AND FOUND THE SUBJECT PROPERTY. LAND SHOWN HEREON FOR EASEMENTS, RIGHT APPEARS TO LIE IN ZONE"X -AREAS DETERMINED TO BE OUTSIDE THE OF WAY, RESTRICTIONS OF RECORD WHICH 0.2%ANNUAL CHANCE FLOODPLAIN AND ZONE"AE", BASE FLOOD MAY AFFECT THE TITLE OR USE OF THE LAND. ELEVATION 103.4. THE SURVEYOR MAKES NO GUARANTEES AS TO THE ABOVE INFORMATION. PLEASE CONTACT THE LOCAL F.E.M.A. AGENT FOR VERIFICATION. 2. NO UNDERGROUND IMPROVEMENTS HAVE'BEEN ' LOCATED EXCEPT AS SHOWN. BEARING BASIS: BEARINGS SHOWN HEREON ARE BASED ON THE CENTERLINE OF WAGONA5hA 3. NOT VALID WITHOUT THE AUTHENTIC TRAIL STREET BEING N53.35'22"W PER PLAT. ELECTRONIC SIGNATURE AND THE AUTHENTIC A M E FR 1 CA N ELECTRONIC SEAL OF A FLORIDA LICENSED REVISED: SURVEYOR AND MAPPER. (FIELD DATE:) .S O F," EY 1 N SCALE: Y= 30 FEET �..; y a yagned bylames W BA-1 8e MAPPING INC. m Z cn=James W Boleman• American Sury yil g&M1 ppin9.ou• APPROVED BY: J6 O o�V .sws ema]H—boleman@asmcorp"mtecom•• CERTIFlCATION OF AUTHORIZATION`NUMBER LB 6393 "" e� '.°.rrn.e c=Us FOR 171013 LOT 22, BLK 6 3191 MAGUE BOULEVARD, SUITE 200z, :;7;,��,;;[+ w�eamiai.leovxv:as-0soo THE Joe No. ORLANDO, FLORIDA 32803 �muwnmmd�� .FIRM (407) 426-7979 DRAWN BY: LO PLAN 11 DSB PT 13 17 KJW WWW.AMERICANSURVEYINGANDMAPPING.COM JAMES'W. BOLEMAN PSM# 6485 ' DATE Single Family Dwelling Plan Review Comments 1. F.F.E. shall be.a rriinimum.of.8",above,the road.elevation and an engineered site plan. 2. Lots shall be graded-to.comply with R401.3 of the F.B.C: . 3. :Compaction:test required if 24" or mor&of fill dirt is brought in:at any.one place. 4.. .Tie in survey required before pouring concrete.". 5. Driveways require a R.O.W. use permit.. A114:sides of.driveway-thru the sidewalk shall Have. expansion material: . . 6. All setbacks shall be'met. 7. All.property markers shall be uncovered and marked at time of first.'ins pection. - 8:. All A.D.A. requirements shall be met. . - 9. No electric,plumbing,:mechanical; or framing shall be covered without an:inspection and approval first. . 10.All Garages shall comply with section R302.6:ofthe.F.B.C. (Fire S:eparation).. 11:Appliances shall not be installed in a location where subject to mechanical damage unless .protected by approvedbarriers- M303.4 of.the F.B:C 12. Water heaters shall comply,with section:P607.3 of the F.B.C.- 13. Foundation supports_for A/C-units shall be raised at least 3" above finished grade. M1308.1. 14. Return aik in all bedrooms. F.B.C. .M,1620.4, . 15: Smoke detectors'are to be'installed in accordance with R313:1 of the.F.B.C. . .16.: All glazing requirements are:to be in accordance with R308.4 of the F.B.C. . 17. All means,of 'e gress. are to be in accordance with R311:of the F:B.C. 18. `.`Green gypsum board"'shall.notbe used:as-a,backer in:showers or tubs. R702AG2 F.B.C. 19. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. 20: Cdtboii monoxide alarms will be required in.new:construction that uses fossil-burningheating or appliances or an attached garage. They shall be installed in accordance with.the F.B.C. 21. All plumbing;mechanical,.and electrical shall be,separate from unit to unit. This includes all underground plumbing and electric: 22. All 2016 N.E.-C-. Codes will be enforced. . .23:Tamper=Resistant Receptacles in-accordance with 406.11 of the 2016 N.E:C 24An accordance.with the Land Development Code, lots shall be sodded before final at least 10. . feet around the structure. 25. Blower door test and blown in insulation card shall be provided before C.O. M.A copy ofthe energy eacls.shall be with permit at all times. 27. Cry of final insulation report shall be:provided with:yerniit before.frnaL F.F.E.-Finished Floor Elevation F.B.C- Florida Building Code 6a'Edition R.O.W.-Right of Way A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2011) FORM R405,-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Hayden 2605 Elev D R , Builder Name: DRH Express Homes / Street: 5 �C.pn�+ J S+ __1) Permit Office: M,Of ?e�,kyeb+zf-s City,State,Zip: Zephyr ills,FL,�N� Permit Number: 1 C -74 Owner: ��.� Jurisdiction: &1(le Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(2614.2 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood,Exterior R=11.0 1285.30 ft2 b.Concrete Block-Int Insul, Exterior R=4.1 996.67 ft2 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 332.22 ft2 4. Number of Bedrooms 5 d.N/A R= ft2 5. Is this a worst case? No 10.Ceiling Types (1541.0 sqft.) Insulation Area a.Under Attic(Vented) R=30.0 1541.00 ft2 6. Conditioned floor area above grade(ft2) 2605 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11.Ducts R ft2 7. Windows(250.0 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 261 a. U-Factor: Dbl, U=0.34 210.00 ft2 SHGC: SHGC=0.31 b. U-Factor: Dbl, U=0.55 40.00 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.34 a.Central Unit 40.0 SEER:14.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 41.0 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 1.692 ft. Area Weighted Average SHGC: 0.315 14.Hot water systems 8. Floor Types (1541.0 sqft.) Insulation Area a.Electric Cap:50 gallonsEF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1104.00 ft2 b. Conservation features b.Raised Floor R=19.0 437.00 ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.096 Total Proposed Modified Loads: 78.66 PASS SS Total Baseline Loads: 79.15 r/1�7�7 1 hereby certify that the plans and specifications covered by Review of the plans and �TJ E ST,q�, this calculation are in compliance with the Florida Energy specifications covered by this0 _ 0� Code. calculation indicates compliance with the Florida Energy Code. ti rrrr, '', PREPARED BY: Before construction is completed c - DATE: n-9-n this building will be inspected for Irul ,a compliance with Section 553.908 * ° I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. SOD yrE1�� OWNER/AGENT BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with Section 803 of RESNET Standards, is not greater than 0.060 Qn for whole house. 1 - 1 1/9/201 7 1 0:13 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2014 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation- Residential Performance Method Project Name: Hayden 2605 Elev D Builder Name: DRH Express Homes Street: ,!']C, C. ,l S� Permit Office: City,State,Zip: ephyr ills, FL, Permit Number: Owner: 1 Jurisdiction: Design Location: FL,Tampa County:: Pasco(Florida Climate Zone 2) 1. New construction or existing New(From Plans) 9. Wall Types(2614.2 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Frame-Wood, Exterior R=11.0 1285.30 ft2 b.Concrete Block-Int Insul, Exterior R=4.1 996.67 ft2 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 332.22 ft2 4. Number of Bedrooms 5 d.N/A R= ft2 10.Ceiling Types (1541.0 sqft.) Insulation Area 5. Is this a worst case? No a.Under Attic(Vented) R=30.0 1541.00 ft2 6. Conditioned floor area above grade(ft2) 2605 b.N/A R= ft2 Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 11. Ducts R ft2 7. Windows(250.0 sqft.) Description Area a.Sup:Attic, Ret:2nd Floor,AH:2nd Floor 6 261 a. U-Factor: Dbl,U=0.34 210.00 ft2 SHGC: SHGC=0.31 b. U-Factor: Dbl,U=0.55 40.00 ft2 12.Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.34 a.Central Unit 40.0 SEER:14.00 c. U-Factor: N/A ft2 - SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a.Electric Heat Pump 41.0 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 1.692 ft. Area Weighted Average SHGC: 0.315 14. Hot water systems 8. Floor Types (1541.0 sqft.) Insulation Area a.Electric Cap:50 gallons EF:0.950 a.Slab-On-Grade Edge Insulation R=0.0 1104.00 ft2 b. Conservation features b.Raised Floor R=19.0 437.00 ft2 None c.N/A R= ft2 15.Credits Pstat Glass/Floor Area: 0.096 Total Proposed Modified Loads: 78.66 ASS Total Baseline Loads: 79.15 I hereby certify that the plans and specifications covered by Review of the plans and �JIM S7-,q?� this calculation are in compliance with the Florida Energy specifications covered by this y Code. calculation indicates compliance '�,,,,�s�'�;% with the Florida Energy Code. rrit.I PREPARED BY: Before construction is completed , DATE: 11-4-17 this buildingwill be inspected for C7 compliance with Section 553.908 * ' ° I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. G'OL)WE OWNER/AGENT; - , BUILDING OFFICIAL: 16?f//-- DATE: / , ,-y 4!5• DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as . certified factory-sealed in accordance with R403.2.2.1. -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with Section 803 of RESNET Standards, is not greater than 0.060 Qn for whole house. 1 1/9/201 7 1 0:13 AM EnergyGauge@ USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 I ' FORM R405-2014 PROJECT Title: Hayden 2605 Elev D Bedrooms: 5 Address Type: Lot Information Building Type: User Conditioned Area: 2605 Lot# 22/6 Owner: Total Stories: 2 Block/SubDivision: Silverado Ranch #of Units: 1 Worst Case: No PlatBook: Builder Name: DRH Express Homes Rotate Angle: 45 Street: Permit Office: Cross Ventilation: County: Pasco Jurisdibtion: Whole House Fan: City,State,Zip: Zephyrhills, Family Type: Single-family FL, ,New/Existing: New(From Plans) Comment: Garage R Face NE CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,Tampa FL_TAMPA_INTERNATI 2 39 91 70 75 645.5 54 Medium BLOCKS Number Name Area Volume 1 Blocki 2605 21579.7 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 - Main 1104 9571.7 Yes 1 1 1 Yes Yes Yes 2 2nd Floor 1501 12008 No 5 4 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio Main 152.8 ft 0 1104 ftz ---- 0.2 0 0.8 2 Raised Floor 2nd Floor ---- ---- 437 ftz 19 0.5 0 0.5 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch v # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 1723 ftz 0 ft2 Dark 0.92 No 0.9 No 0 26.6 / ATTIC V # Type Ventilation Vent Ratio(1 in) Area FIBS IRCC 1 Full attic Vented 300 1541 ftz Y N 11/9/2017 10:13 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1'Compliant Software Page 2 of 5 FORM R405-2014 CEILING # ' Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Vented) Main 30 Blown 40 ftz 0.11 Wood 2 Under Attic(Vented) 2nd Floor 30 Blown 1501 ftz 0.11 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 N=>NE Exterior Concrete Block-Int Insul Main 4.1 18 8 8 8 161.8 ftz 0 0.6 0 2 W=>NW Exterior Concrete Block-Int Insul Main 4.1 20 8 8 173.3 ftz 0 0.6 0 3 S=>SW Exterior Concrete Block-Int Insul Main 4.1 39 8 8 8 343.8 ftz 0 0.6 0 4 E=>SE Exterior Concrete Block-Int Insul Main 4.1 36 8 8 8 317.8 ftz 0 0.6 0 5 N=>NE Garage Frame-Wood Main 11 20 4 8 8 176.2 ftz 0.23 0.01 0 6 W=>NW Garage Frame-Wood Main 11 18 0 8 8 156.0 ftz 0.23 0.01 0 7 N=>NE Exterior Frame-Wood 2nd Floor 11 39 8 8 317.3 ftz 0.23 0.6 0 8 W=>NW Exterior Frame-Wood 2nd Floor 11 40 8 8 325.3 ftz 0.23 0.6 0 9 S=>SW Exterior Frame-Wood 2nd Floor 11 39 8 8 317.3 ftz 0.23 0.6 0 10 E=>SE Exterior Frame-Wood 2nd Floor 11 40 8 8 325.3 ftz 0.23 0.6 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N=>NE Insulated Main None .4 3 6 8 20 ftz 2 N=>NE Wood Main None .46 2 8 6 8 17.8 ftz WINDOWS Orientation shown is the entered orientation => changed to As Built rotated 45 degrees). / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N=>NE 1 Vinyl Low-E Double Yes 0.34 0.31 31.0 ftz 6 ft 2 in 1 ft 0 in Drapes/blinds None 2 N=>NE 1 Vinyl Low-E Double Yes 0.34 0.31 2.5 ftz 6 ft 2 in 0 ft 0 in Drapes/blinds None 3 S=>SW 3 Vinyl Low-E Double Yes 0.34 0.31 46.5 ftz 1 ft 0 in 10 ft 6 in Drapes/blinds None 4 S=>SW 3 Metal Low-E Double Yes 0.55 0.34 40.0 ftz 1 ft 0 in 1 ft 3 in Drapes/blinds None 5 N=>NE 7 Vinyl Low-E Double Yes 0.34 0.31 6.0 ftz 1 ft 0 in 0 ft 6 in Drapes/blinds None 6 N=>NE 7 Vinyl Low-E Double Yes 0.34 0.31 31.0 ftz 1 ft 0 in 2 ft 6 in Drapes/blinds None 7 S=>SW 9 Vinyl Low-E Double Yes 0.34 0.31 62.0 ftz 1 ft 0 in 0 ft 6 in Drapes/blinds None 8 N=>NE 7 Vinyl Low-E Double Yes 0.34 0.31 31.0 ftz 1 ft 0 in 0 ft 6 in Drapes/blinds None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 437.038 ftz 437.038 ftz' 48.4 ft 8.67 ft 0 11/9/2017 10:13 AM EnergyGauge@ USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2014 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000368 2517.6 138.21 259.93 .3402 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump None HSPF:8.2 41 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit None SEER:14 40 kBtu/hr 1200 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.95 50 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None ftz DUCTS / ----Supply---- ----Return---- Air CFM 25 CFM25 HVAC# # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 261 ftz 2nd Floor 45 ft2 Proposed Qn 2nd Floor ---cfm 156.3 cfm 0.06 0.60 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans: CoolingJan Feb Mar Apr May Jun Jul AugSe Oct Nov Dec Heatin f X�Jan f Xj Feb f X�Mar f Apr May Jun Jul AuSeP Oct Nov Dec Venting [ ]Jan [ ]Feb [X]Mar [X]Apr May Jun Jul Aug Se Oct Nov Dec 11/9/2017 10:13 AM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 -n m CD 0 0 0 = w w p o =r m 7J N (o (o (=O fo c' 0 m �J m o m o v cn En O , , w m N O n D C. 1 m oD oD mD vD c O 0 m mm mm VV wV s (gyp w m w m w w O w m CD m O l m mm mm VV wV w N mm mm ww C Ow O C > mm mm VV VV CO D mm mm woo ww m A) Di N mm mm ww ww .4. N O_ A co CD mm mm V V V V o mm mm ww ww U' O 7 ' .A 0 mm mm VV VV m a ww ww ww ww 2 0 C O � mm mm VV VV V ww mm mm mm w 7 O m m m m V V V V w ww ww ww ww (D mm mm VV Vw (D 0000 w w w w w 0 MG) m m V V V w 0000 w w 0300 w 0 O (3)O) m Q) V V V w m w MOD w w w 0 s w co CD Ul p mm mm VV Vm -� mm mm ww w0 N Ul FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the EnergyPerformance Index,the more efficient the home. Zephyrhills, FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Frame-Wood, Exterior R=11.0 1285.30 ft2 b.Concrete Block-Int Insul, Exterior R=4.1 996.67 ft 3. Number of units,if multiple family 1 c.Frame-Wood,Adjacent R=11.0 332.22 ft2 4. Number of Bedrooms 5 d.N/A R= ft2 10.Ceiling Types Insulation Area 5. Is this a worst case? No a.Under Attic(Vented) R=30.0 1541.00 ft2 6. Conditioned floor area(ft2) 2605 b.N/A R= ft2 7. Windows" Description Area c.N/A R= ft2 a. U-Factor: Dbl, U=0.34 210.00 ft2 11. Ducts R ft2 SHGC: SHGC=0.31 a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 261 b. U-Factor: DO, U=0.55 40.00 ft2 SHGC: SHGC=0.34 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a.Central Unit 40.0 SEER:14.00 SHGC: d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Heat Pump 41.0 HSPF:8.20 Area Weighted Average Overhang Depth: 1.692 ft. Area Weighted Average SHGC: 0.315 8. Floor Types Insulation Area 14.Hot water systems a.Electric Cap:50 gallons a.Slab-On-Grade Edge Insulation R=0.0 1104.00 ft2 EF:0.95 b. Raised Floor R=19.0 437.00 ft2 c.N/A R= ft2 b. Conservation features None 15.Credits Pstat I certify that this home has complied with the Florida Energy Efficiency Code for Building E Sr Construction through the above energy saving features which will be installed (or exceeded) All, in this home before final inspection. Otherwise, a new EPL Display Card will be completed ��v4j'°�i •_`-�',o�{ based on installed Code compliant features. •lvrr„' ';, O Builder Signature: / Date: Address of New Home: t ' City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 1 1/9/201 7 1 0:13 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 Florida Department of Business and Professional Regulations Residential Whole Building Performance and Prescriptive Methods ADDRESS: Permit Number: Zephyrhills, FL, MANDATORY REQUIREMENTS See individual code sections for full details. 401.3 Energy Performance Level(EPL)display card(Mandatory). The building official shall require that an energy performance level(EPL) display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law [Section 553.9085,Florida Statues]requires the EPL display card to be included as an addendum to each sales contract for both presold and nonpresold residential buildings.The EPL display card contains information indicating the energy performance level and efficiencies of components installed in a dwelling unit.The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans and specifications submitted to demonstrate compliance for the building.A copy of the EPL display card can be found in Appendix C. R402.4 Air leakage(Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of Sections R402.1 through R402.4.4. O R402.4.1 Building thermal envelope. The building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.The sealing methods between dissimilar materials shall allow for differential expansion and contraction. • R402.4.1.1 Installation. The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance with the manufacturer's instructions and the criteria listed in Table 402.4.1.1,as applicable to the method of construction. Where required by the code official,an approved third party shall inspect all components and verify compliance. • R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2,and 3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1. Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2. Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3. Interior doors,if installed at the time of the test,shall be open; 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. O R402.4.2 Fireplaces. New wood-burning fireplaces shall have tight-fitting flue dampers and outdoor combustion air. O R402.4.3 Fenestration air leakage.Windows,skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per square foot(1.5 Us/m2),and swinging doors no more than 0.5 cfm per square foot(2.6 Us/m2),when tested according to NFRC 400 or AAMA/WDMA/CSA 101/I.S.2/A440 by an accredited,independent laboratory and listed and labeled by the manufacturer. Exception: Site-built windows,skylights and doors. O R402.4.4 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage between conditioned and unconditioned spaces.All recessed luminaires shall be IC-rated and labeled as having an air leakage rate not more than 2.0 cfm (0.944 Us)when tested in accordance with ASTM E 283 at a 1.57 psf(75 Pa)pressure differential.All recessed luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering. R403.1.1 Thermostat provision(Mandatory). At least one thermostat shall be provided for each separate heating and cooling system. R403.1.3 Heat pump supplementary heat(Mandatory). Heat pumps having supplementary electric-resistance heat shall have controls that,except during defrost,prevent supplemental heat operation when the heat pump compressor can meet the heating load. R403.2.2 Sealing(Mandatory)AII ducts,air handlers,and filter boxes and building cavities that form the primary air containment passageways for air distribution systems shall be considered ducts and plenum chambers,shall be constructed and sealed in accordance with Section C403.2.7.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria by post-construction or rough-in testing below. Duct tightness shall be verified by testing to Section 803 of the RESNET Standards by either an energy rater certified in accordance with Section 553.99, Florida Statutes,or as authorized by Florida Statutes,to be"substantially leak free"by either of the following: 1. Post-construction test:Total leakage shall be less than or equal to 4 cfm (113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g.(25 Pa)across the entire system,including the manufacturer's air handler enclosure.All register boots shall be taped or otherwise sealed during the test. 2. Rough-in test:Total leakage shall be less than or equal to 4 cfm(113 Umin)per 100 square feet(9.29 m2)of conditioned floor area when tested at a pressure differential of 0.1 inches w.g. (25Pa)across the system,including the manufacturer's air handler enclosure.All registers shall be taped or otherwise sealed during the test. If the air handler is not installed at the time of the test,total leakage shall be less than or equal to 3 cfm (85 Umin)per 100 square feet(9.29 m2)of conditioned floor area. Exceptions: 1. The total leakage test is not required for ducts and air handlers located entirely within the building envelope. 2. Duct testing is not mandatory for buildings complying by Section R405 of this code. 1 1/9/201 7 1 0:13 AM EnergyGaugeOO USA-FlaRes2014 -Section R405.4.1 Com Page 1 of 3 FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) ❑ R403.2.3 Building Cavities(Mandatory). Building framing cavities shall not be used as ducts or plenums. ❑ R403.3 Mechanical system piping insulation(Mandatory). Mechanical system piping capable of carrying fluids above 105°F(41°C) or below 55°F(1 YC)shall be insulated to a minimum of R-3., R403.3.1 Protection of piping insulation. ❑ R403.4.1 Circulating hot water systems(Mandatory). Circulating hot water systems shall be provided with an automatic or readily accessible manual switch that can turn off the hot-water circulating pump when the system is not in use. ❑ R403.4.3 Heat traps(Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have heat traps installed on both the inlets and outlets.External heat traps shall consist of either a commercially available heat trap or a downward and upward bend of at least 3 1/2 inches(89 mm)in the hot water distribution line and cold water line located as close as possible to the storage tank. ❑ R403.4.4 Water heater efficiencies(Mandatory). O R403.4.4.1 Storage water heater temperature controls • R403.4.4.1.1 Automatic controls. Service water heating systems shall be equipped with automatic temperature controls capable of adjustment from the lowest to the highest acceptable temperature settings for the intended use.The minimum temperature setting range shall be from 100°F to 140°F(38°C to 60°C). • R403.4.4.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to electric service systems to be turned off.A separate valve shall be provided to permit the energy supplied to the main burner(s) of combustion types of service water heating systems to be turned off. O R403.4.4.2 Water heating equipment. Water heating equipment installed in residential units shall meet the minimum efficiencies of Table C404.2 in Chapter 4 of the Florida Building Code,Energy Conservation,Commercial Provisions,for the type of equipment installed. Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate water heating category. Solar water heaters shall met the criteria Section R403.4.4.2.1. R403.4.4.2.1 Solar water heating systems. Solar systems for domestic hot water production are rated by the annual solar energy factor of the system.The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of Certified Solar Systems.Solar collectors shall be tested in accordance with ISO Standard 9806,Test Methods for Solar Collectors, and SRCC Standard TM-1,Solar Domestic Hot Water System and Component Test Protocol,Collectors in installed solar water heating systems should meet the following criteria: 1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal;and 2. Be installed at an orientation within 45 degrees of true south. ❑ R403.5 Mechanical ventilation(Mandatory). The building shall be provided with ventilation that meets the requirements of the Florida Building Code,Residential or Florida Building Code,Mechanical,as applicable,or with other approved means of ventilation. Outdoor air intakes and exhausts shall have automatic or gravity dampers that close when the ventilation system is not operating. ❑ R403.6 Heating and cooling equipment(Mandatory). The following sections are mandatory for cooling and heating equipment. O R403.6.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies, based on building loads for the directional orientation of the building.The manufacturer and model number of the outdoor and indoor units(if split system)shall be submitted along with the sensible and total cooling capacities at the design conditions described in Section R302.1.This code does not allow designer safety factors,provisions for future expansion or other factors which affect equipment sizing.System sizing calculations shall not include loads created by local intermittent mechanical ventilation such as standard kitchen and bathroom exhaust systems. • R403.6.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less than the calculated total load,but not more than 1.15 times greater than the total load calculated according to the procedure selected in Section 403.6,or the closest available size provided by the manufacturer's product lines.The corresponding latent capacity of the equipment shall not be less than the calculated latent load. 11/9/2017 10:13 AM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Com Page 2 of 3 FORM R405-2014 MANDATORY REQUIREMENTS - (Continued) O R403.6.1.1 Cooling equipment capacity.(continued) The published value for AHRI total capacity is a nominal,rating-test value and shall not be used for equipment sizing.Manufacture's expanded performance data shall be used to select cooling-only equipment.This selection shall be used to select cooling-only equipment.This selection shall be based on the outdoor design dry bulb temperature for the load calculation(or entering water temperature for water-source equipment),the blower cfm provided by the expanded performance data, the design value for entering wet bulb temperature and the design value for entering dry bulb temperature. Design values for entering wet bulb and dry bulb temperature shall be for the indoor dry bulb and relative humidity used for the load calculation and shall be adjusted for return side gains if the return duct(s)is installed in an unconditioned space. Exceptions: 1. Attached single-and multi-family residential equipment sizing may be selected so that its cooling capacity is less than the calculated total sensible load but not less than 80 percent of that load. 2. When signed and sealed by a Florida-registered engineer,in attached single-and multi-family units,the capacity of equipment may be sized in accordance with good design practice. O R403.6.1.2 Heating equipment capacity • R403.6.1.2.1 Heat pumps. Heat pumps sizing shall be based on the cooling requirements as calculated according to Section R403.6.1.1 and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load. • R403.6.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design requirements calculated according to the procedure selected in Section R403.6.1. • R403.6.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners shall not be less than the design load calculated in accordance with Section R403.6.1. O R403.6.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an intermittent basis,such as anticipated additional loads caused by major entertainment events,shall have equipment sized or controlled to prevent continuous space cooling or heating within that space by one or more of the following options: 1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas. 2. A variable capacity system sized for optimum performance during base load periods is utilized. ❑ R403.7 Systems serving multiple dwelling units(Mandatory). Systems serving multiple dwelling units shall comply with Sections C403 and C404 of the Commercial Provisions in lieu of Section R403. ❑ R403.8 Snow melt system controls(Mandatory). Snow and ice-melting systems,supplied through energy service to the building,shall include automatic controls capable of shutting off the system when the pavement temperature is above 55°F,and no precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F. ❑ R403.9 Swimming pools,inground spas and portable spas(Mandatory). The energy requirements for residential pools and inground spas shall be as specified in Sections R403.9.1 through R403.9.3 and in accordance with ANSI/APSP-15.The energy requirements for portable spas shall be in accordance with ANSI/APSP-14. O R403.9.1 Pool and spa heaters. All pool heaters shall be equipped with a readily accessible on-off switch that is mounted outside the heater to allow shutting off the heater without adjusting the thermostat setting. R403.9.1.1 Gas and oil-fired pool and spa heaters. All gas-and oil-fired pool and space heaters shall have a minimum thermal efficiency of 82 percent for heaters manufactured on or after April 16,2013 when tested in accordance with ANSI Z 21.56. Pool heaters fired by natural gas or LP gas shall not have continuously burning pilot lights. R403.9.1.2 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance with AHRI 1160,Table 2,Standard Rating Conditions-Low Air Temperature.A test report from an independent laboratory is required to verify procedure compliance.Geothermal swimming pool heat pumps are not required to meet this standard. O R403.9.2 Time switches. Time switches or other control method that can automatically turn off and on heaters and pumps according to a preset schedule shall be installed on all heaters and pumps. Heaters,pumps and motors that have built in timers shall be deemed in compliance with this equipment. Exceptions: 1. Where public health standards require 24-hour pump operations. 2. Where pumps are required to operate solar-and waste-heat-recovery pool heating systems. 3. Where pumps are powered exclusively from on-site renewable generation. O R403.9.3 Covers. Heated swimming pools and inground permanently installed spas shall be equipped with a vapor-retardant cover on or at the water surface or a liquid cover or other means proven to reduce heat loss. Exception: Outdoor pools deriving over 70 percent of the energy for heating from site-recovered energy,such as a heat pump or solar energy source computed over an operating season. ❑ RR404.1 Lighting equipment(Mandatory). A minimum of 75 percent of the lamps in permanently installed lighting fixtures shall be high-efficacy lamps or a minimum of 75 percent of permanently installed lighting fixtures shall contain only high efficacy lamps. Exception: Low-voltage lighting shall not be required to utilize high-efficacy lamps. O R404.1.1 Lighting equipment(Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights ❑ R405.2 Performance ONLY. All ducts not entirely inside the building thermal envelope shall be insulated to a minimum of R-6. O R405.2.1 Performance ONLY. Ceilings shall have minimum insulation of R-19.Where single assemby of the exposed deck and beam type or concrete deck roofs do not have sufficent space, R-10 is allowed. 1 1/9/201 7 1 0:13 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Com Page 3 of 3 FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Hayden 2605 Elev D Builder Name: DRH Express Homes Street: Permit Office: City,State,Zip: Zephyrhills, FL, Permit Number: Owner: Jurisdiction: Design Location: FL,Tampa COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks or joints in the air barrier shall be sealed. Air-permeable insulation shall not be used as a sealing material. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings,drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/doorjambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above-garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation,insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations,and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be air tight, IC rated,and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls,or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub-floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 11/9/2017 10:13 AM EnergyGaugeO USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Envelope Leakage Test Report Prescriptive and Performance Method Project name: Hayden 2605 Elev D Builder Name: DRH Express Homes Street: Permit Office: City,State,Zip: Zephyrhills, FL, Permit Number: Design Location: FL,Tampa Jurisdiction: Cond. Floor Area:: 2605 sq.ft. Cond.Volume: 21580 cu ft. Envelope Leakage Test Results Leakage Characteristics Regression Data: C: n: R: CFM(50): Single or Multi Point Test Data HOUSE PRESSURE FLOW: ELA' 1 Pa cfm EgLA: 2 Pa cfm ACH: 3 Pa cfm ACH(50): 4 Pa cfm 5 Pa cfm SLA: 6 Pa cfm R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 5 air changes per hour in Climate Zones 1 and 2,3 air changes per hour in Climate Zones 3 through 8.Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g.(50 Pascals).Where required by the code official,testing shall be conducted by an approved third party.A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. During testing: 1.Exterior windows and doors,fireplace and stove doors shall be closed,but not sealed,beyond the intended weatherstripping or other infiltration control measures; 2.Dampers including exhaust,intake,makeup air,backdraft and flue dampers shall be closed,but not sealed beyond intended infiltration control measures; 3. Interior doors,if installed at the time of the test,shall be open; 4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed; 5.Heating and cooling systems,if installed at the time of the test,shall be turned off;and 6.Supply and return registers,if installed at the time of the test,shall be fully open. I hereby certify that the above envelope leakage Where required by the code official, D 114E STA � performance results demonstrate compliance testing shall be conducted by an with Florida Energy Code requirements in approved third party. A written accordance with Section R402.4.1.2. report of the results of the test shallc be signed by the third party cA ........fry`"z.... conducting the test and provided to INli: SIGNATURE: the code official. PRINTED NAME: DATE: BUILDING OFFICIAL: DATE: 1 1/9/201 7 1 0:14 AM EnergyGauge@ USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 Duct Leakage Test Repdrt Performance Method FLORIDA ENERGY EFFICIENCY- CODE FOR BUILDING CONSTRUCTION Form R405 Duct Leakage Test Report Performance Method Project Name: Hayden 2605 Elev D Builder Name: DRH Express Homes Street: Permit Office: City,State,Zip: Zephyrhills, FL, Permit Number: Design Location: FL,Tampa Jurisdiction: Duct Test Time: Post Construction Duct Leakage Test Results CFM25 Duct Leakage Test Values Line System Outside Duct Leakage 1 System 1 cfm25(Out) 2 System 2 cfm25(Out) 3 System 3 cfm25(Out) 4 System 4 cfm25(Out) 5 Total House Sum lines 1-4 Duct System Leakage Divide by - (Total Conditioned Floor Area) (Qn,Out) I certify the tested duct leakage to outside, Qn, is not greater than the proposed duct leakage Qn Duct tightness shall be verified by O vaE STq? Q specified on Form R405-2014. testing to Section 803 of the RESNET , , Standards by an energy rater certified in '�r� �� , AS accordance with Section 553.99, Florida Statutes. ......... j.__ _ O SIGNATURE: PRINTED NAME: cDD WE DATE: BUILDING OFFICIAL: DATE: 1 1/9/201 7 1 0:14 AM EnergyGaugeO USA-FlaRes2014 -Section R405.4.1 Compliant S Page 1 of 1 Manual S Compliance Report Job: - + wrightsoft* p p Date: Oct 10,2014 Entire House By: Progressive Air Systems, Inc 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 Project • • For: DR Horton/Express Lot 22 Blk 6 Silverado, Zephyrhills, FL Cooling Equipment Design Conditions Outdoor design DB: 91.2°F Sensible gain: 30501 Btuh Entering coil DB: 76.4°F Outdoor design WB: 77.1 OF Latent gain: 4144 Btuh Entering coil WB: 63.2°F Indoor design DB: 75.0°F Total gain: 34645 Btuh Indoor RH: 50% Estimated airflow: 1367 cfm Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB042****A+FB4CNP042 Actual airflow: 1367 cfm Sensible capacity: 32445 Btuh 106%of load Latent capacity: 6269 Btuh 151%of load Total capacity: 38714 Btuh 1120%of load SHR: 849/o tinq.,Equipmenj., Design Conditions Outdoor design DB: 40.0°F Heat loss: 27149 Btuh Entering coil DB: 69.5°F Indoor design DB: 70.0°F Manufacturer's Performance Data at Actual Design Conditions Equipment type: Split ASHP Manufacturer: Carrier Model: CH14NB042****A+FB4CNP042 Actual airflow: 1367 cfm Output capacity: 37299 Btuh 1370%of load Capacity balance: 31 OF Supplemental heat required: 0 Btuh Economic balance: -99 OF Backup equipment type: Elec strip Manufacturer: Model: Actual airflow: 1367 cfm Output capacity: 8.6 kW 108%of load Temp. rise: 18 OF Meets are all requirements of ACCA Manual S. wri htsofts 2017-Nov-0910:17:10 ,ZA 9 Right-Suite®Universal 2017 17.0.21 RSU25554 Page 1 tA ...\Wrightsoft Files\Express homes\Hayden-4EHB.rup Calc=MJ8 House faces:NE b Load Short F Job: -�- wrightsoftm, Form Date: Oct 10,2014 Entire House By: Progressive Air Systems, Inc 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 ProjectInfOrmation For: DR Horton/Express Lot 22 Blk 6 Silverado, Zephyrhills, FL 'Design In • • Htg Clg Infiltration Outside db(°F) 40 91 Method Simplified Inside db(°F) 70 75 Construction quality Semi-tight Design TD (°F) 30 16 Fireplaces 0 Daily range - L Inside humidity (%) 50 50 Moisture difference(gr/lb) 26 54 HEATING EQUIPMENT COOLING EQUIPMENT Make Carrier Make Carrier Trade CARRIER Trade CARRIER Model CH14NB042****A Cond CH14NB042****A AHRI ref Coil FB4CNP042 AHRI ref .Efficiency 8 HSPF Efficiency 11.3 EER, 13.7 SEER Heating input Sensible cooling 30750 Btuh Heating output 38500 Btuh @ 47°F Latent cooling 10250 Btuh Temperature rise 26 OF Total cooling 41000 Btuh Actual air flow 1367 cfm Actual air flow 1367 cfm Air flow factor 0.050 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 0.56 in H2O Static pressure 0.56 in H2O Space thermostat Load sensible heat ratio 0.88 Capacity balance point=31 OF Backup: . Input=9 kW, Output=29290 Btuh, 100 AFUE ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (f12) (Btuh) (Btuh) (cfm) (cfm) kitchen/living 608 7370 8809 371 395 bed 2 164 2960 2019 149 90 powder 59 968 394 49 18 flex 156 3106 2422 156 109 foyer 75 1443 954 73 43 stairs 44 0 0 0 0 bed4 181 1647 2220 83 100 bed3 184 1965 2606 99 117 wic 60 143 190 7 ' 9 wic 2 32 706 722 36 32 m suite 277 2507 3364 126 151 bath 135 355 380 18 17 upstairs living 234 1366 2665 69 119 stairs 2 50 0 0 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. .` wrl htsoft6 2017-Nov-0910:17:10 ,.�. 9 Right-Suite®Universal 2017 17.0.21 RSU25554 Page 1 �+� ...\Wdghtsoft Files\Express homes\Hayden-4EHB.rup Calc=MJ8 House faces:NE bed5 175 1606 2174 81 97 laundry 41 368 983 19 44 a/c 19 0 0 0 0 bath 3 96 639 599 32 27 hall 63 0 0 , 0 0 Entire House d 2651 27149 30501 1367 1367 Other equip loads 0 0 Equip. @ 1.00 RSM 30501 Latent cooling 4144 TOTALS 2651 27149 34645 1367 1367 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 1 wri �9tSOft 2017-Nov-0910:17:10 9 Right-Suite®Universal 2017 17.0.21 RSU25554 Page 2 ACCK ..\Wrightsoft Files\Express homes\Hayden-4EHB.rup calc=MJ8 House faces:NE t i 4 Project Summary Job: - wrightsoft® Entire House Y �DDate: Oct 10,2014 Progressive Air Systems, Inc 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 s rdidalrlf•rmati• For: DR Horton/Express Lot 22 Blk 6 Silverado, Zephyrhills, FL Notes: , - o • • Weather: Tampa Intl AP, FL, US Winter Design Conditions Summer Design Conditions Outside db 40 OF Outside db 91 OF Inside db 70 OF Inside db 75 OF Design TD 30 OF Design TD 16 OF Daily range L Relative humidity 50 % Moisture difference 54 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 20520 Btuh Structure 21513 Btuh Ducts 6629 Btuh Ducts 8988 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 27149 Btuh Use manufacturer's data y Rate/swing multiplier 1.00 Infiltration Equipment sensible load 30501 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 0 Structure 2674 Btuh Ducts 1469 Btuh Central vent (0 cfm) 0 Btuh Heating Coolingg (none) Area(ftz) 2651 2651 Equipment latent load 4144. Btuh Volume(ft3) 22094 22094 Air changes/hour 0.22 0.11 Equipment total load 34645 Btuh Equiv.AVF(cfm) 81 41 Req. total capacity at 0.75 SHR 3.4 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIER Trade CARRIER Model CH14NB042****A Cond CH14NB042****A AHRI ref Coil FB4CNP042 AHRI ref. Efficiency 8 HSPF Efficiency 11.3 EER, 13.7 SEER Heating input Sensible cooling 30750 Btuh Heating output 38500 Btuh @ 470F Latent cooling 10250 Btuh Temperature rise 26 OF Total cooling 41000 Btuh Actual air flow 1367 cfm Actual air flow 1367 cfm Air flow factor 0.050 cfm/Btuh Air flow factor 0.045 cfm/Btuh j Static pressure 0.56 in H2O Static pressure 0.56 in H2O Space thermostat Load sensible heat ratio 0.88 Capacity balance point=31 OF Backup: Input= 9 kW, Output=29290 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. WCIg htsoft" 2017-Nov-0910:17:10 ACC Right-Suite®Universal 2017 17.0.21 RSU25554 Page 1 ...\Wrightsoft Files\Express homes\Hayden-4EHB.rup Calc=MJ8 House faces:NE FORM R405-2014 RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST Florida Department of Business and Professional Regulation Simulated Performance Alternative (Performance)Method Applications for compliance with the 2014 Florida Building Code, Energy Conservation via the residential Simulated Performance method shall include ❑ This checklist ❑ A Form R405 report that documents that the Proposed Design complies with Section R405.3 of the Florida Energy Code. This form shall include a summary page indicating home address, a-ratio and the pass or fail status along with summary areas and types of components, whether the home was simulated as a worst-case orientation, name and version of the compliance software tool, name of individual completing the compliance report(1 page)and an input summary checklist that can be used for field verification (usually 4 pages/may be greater). ❑ Energy Performance Level(EPL) Display Card(one page) ❑ Mandatory Requirements(three pages) Required prior to CO for the Performance Method: ❑ Air Barrier and Insulation Inspection Component Criteria checklist(Table R402.4.1.1 - one page) ❑ A completed Envelope Leakage Test Report(usually one page) ❑ If Form R405 duct leakage type indicates anything other than "default leakage", then a completed Form R405 Duct Leakage Test Report(usually one page) EnergyGauge®-USRCZB v5.1 11/8/20J74:39:53 PM Page 1 of 1 I CITY OF / / / / BUI LDING ZEPHYRHILLSNOTICE DEPARTMENT OF ADDITION OR CORRECTION D • NOTIREMOVE ADDRESS� �G TE PERMIT 5 Nil THIS JOB HAS NOT BEEN COMPLETED. The following additions or corrections shall be made before the job will be accepted. 'S C4 el Q It is unlawful for any Carpenter,Contractor,Builder,or other persons,to AFTER CORRECTIONS ARE M CALL cover or cause to be covered,any part of the work with flooring,lath,earth 780-0020 70;r TION or other material,until the proper inspector has had ample time to approve the installation. OFFICE HOURS 7:30AM-4:30 PM MON.-FRI. INSPECTOR . 2 CITY OF " NOTICE " / / BUILDING ZEPHYRHILLS DEPARTMENT OF ADDITION OR CORRECTION D • NOT REMOVE ADDRESS DATE PERMIT f s THIS JOB HAS NOT BEEN COMPLETED. The following additions or corr ctions shall be made before the job will be accepted. Y� It is unlawful for any Carpenter,Contractor,Builder,or other persons,to AFTER CORRECTIONS ARE MADE ALL cover or cause to be covered,any part of the work with flooring,lath,earth 780-0020 FOR RE-INSP N or other material,until the proper inspector has had ample time to approve the installation. OFFICE HOURS 7:30AM-4:30 PM MON.-FRI. INSPECTOR ENVIRONMENTS FOR r SITE ID:410761 LOT:22 BLOCKS HOUSE:6525 STREET:WAGON TRAIL ST CITY:ZEPHYRHILLS STATE:FL 71P:33541 COUNTY:PASCO ACCOUNT#:g09DRHFL BUILDER:DR HORTON SUBDMSION:SILVERADO COMMUNITY:39163 PLAN:NDP 12I122016 PROGRAM:CODE1700% TESTER:EFL IECC:2009 CLIMATE ZONE: PROPERTY OWNER: PROPERTY ADDRESS:6525 WAGON TRAIL ST,ZEPHYRHILLS,FL 33541 TEST:BLOWER DOOR RESULT:PASS TESTER:Michael Silberstein DATE:121312018 TEST NAME CORRECTION BUILDER RATER WA NEEDED VERIFIED VERIFIED 5.1 Attic Access Panel(fully gasketed and insulated) X 5.2 Attie drop-down Stair(fully gasketed and insulated) X 5.4 Recessed Lighting Fixtures(ICAT labeled and sealed to drywal4 X 5.5 Whole-house Fan(insulated gasketed to the opening X 7.3 Fresh air ventilation installed per program specs X Blower Door BUILDING ORIENTATION PROGRAM CODE PROGRAM CODE VOLUME CU. VOLUME CU. SHELL SG. SHELL SO. WA 21,613 0 0 PROGRAM CODE PROGRAM CODE PROGRAM CODE CFM 50 CFM 50 ACH 50 ACH 50 %of Shell %of Shag BD Target 0 12.522 7 BD Actual 2,090 5.8 Meter# Room Pressure Test Mat Bdmt 0 Bdrm 2 0 Bdrm 3 0 Bdrm 4 0 Bdnn 5 0 Rm 1 0 Rm 2 0 Rm 3 0 Other 0 CO Detectors Energy Star Qualified Appliances? EfSaent Lighting Package? 60 or>Of Hardwired Lights Must Be CFL Or LED Low Flow Faucets,Toilets etc? Programmable Thermostat? Certified Green Program Level Requires Visual Inspection Mechanical System hem Location Manufacturer Nam Model#1 Model#2 Model#3 Model#4 SYSTEM WATER HEATER SYSTEM WATER HEATER SYSTEM WATER HEATER SYSTEM WATER HEATER SYSTEMI FURNACE SYSTEM 1 HVAC OUTDOOR OUTSIDE UNIT SYSTEM 1 HVAC INDOOR COIL SYSTEM HVAC AHU(HEAT INTERIOR PUMP) SYSTEM FURNACE SYSTEM 2 HVAC OUTDOOR UNIT SYSTEM 2 HVAC INDOOR COIL SYSTEM 2 HVAC AHU(HEAT PUMP) SYSTEM 3 FURNACE SYSTEM 3 HVAC OUTDOOR UNIT SYSTEM 3 HVAC INDOOR COIL SYSTEM 3 HVAC AHU(HEAT PUMP) SYSTEM 4 FURNACE SYSTEM HVAC OUTDOOR UNIT SYSTEM 4 HVAC INDOOR COIL SYSTEM 4 HVAC AHU(HEAT PUMP BUILDING SPECIFICATIONS BUILDING CHARACTERISTICS ASDESIGN-VALUES ASBUILT-VALUES COMMMENT #OF BEDROOMS(REM) NA NA CEILING FLAT(REM) NA NA SEALED ATTIC(REM) NA NA VAULTED CEILING(REM) NA NA FOUNDATION WALLS(REM) NA NA EXPOSED FLOOR(REM) NA NA ABOVE GRADE WALLS(REM) NA NA DUCT SUPPLY R-VALUE(REM) NA NA DUCT RETURN R-VALUE(REM) NA NA PROGRAMMABLE THERMOSTATS(PRIF) WATER HEATER TYPE(PRIF) WATER HEATER FUEL TYPE(PRIF) TEST: BLOWER DOOR RESULT:PASS TESTER: Michasi SObersteln DATE'12+312018 r BUILDING SPECIFICATIONS BUILDINGCHARACTEkSTICS " ASDESIGN-VALUES AS BUILT-VALUES COMMMENT WATER HEATER SIZE, EFFICIENCY 8 LOCATION (PRIF) INFILTRATION(HOUSE LKG)ACH(REM) NA Hlg:5.8 Clg:5.8 ACH @ 50 Pascals FRESH AIR VENTILATION TYPE(PRIF) VENTILATION FAN MANUFACTURER(REM) NA NA VENTILATION FAN MODEL#(REM) NA NA VENTILATION FLOW REQUIRED(REM) NA NA VENTILATION EQUIP.RATED CFM(REM) NA NA VENTILATION#OF FANS(REM) NA NA VENTILATION TIMER SETTING EACH FAN(REM) NA NA VENTILATION TIME-HRSIDAYSPECIFIED(REM) NA NA VENTILATION TIME SET BY HVAC CONTRACTOR- MINUTES PER HOUR(PRIF) FRESH AIR VENTILATION FAN WATTS(REM) NA NA MEASURED FAN WATTS OR PER MANUFACTURER'S SPEC'S(PRIF) INTERIOR%OF CFUS(PRIF) INTERIOR%OF LED'S(PRIF) INTERIOR%OF PIN-BASED(PRIF) EXTERIOR FIXTURES%OF CFUS(PRIF) EXTERIOR FIXTURES%OF LED'S(PRIF) GARAGE FIXTURES%OF CFUS(PRIF) GARAGE FIXTURES%OF LED'S(PRIF) DISHWASHER(PRIF) REFRIGERATOR(PRIF) FOUNDATION TYPE(PRIF) SLAB TYPE(PRIF) SLAB AREA(PRIF) SLAB DEPTH(PRIF) SLAB FULL PERIMETER(PRIF) SLAB GRADE(PRIF) FLOW RING(PRIF) HEATING(REM) NA NA COOLING(REM) NA NA AIR-SOURCE HP(REM) NA NA WATER HEATING(REM) NA NA TEST: DUCT BLASTER RESULT:PASS TESTER:Michael Silberstein DATE:12*12018 TOTAL CONDITIONED FLOOR AREA 0 2,605 (CFA SQ FT) DUCT LEAKAGE TO OUTSIDE%TARGET 0.00% 3.00% TOTAL DUCT LEAKAGE%TARGET 0.00% 8.00% SYSTEM 1 SQ FT.SERVED(CFA) 0 2.605 POST CONSTRUCTION SYSTEM 1 DUCT LEAKAGE TO OUTSIDE 0 78 SYSTEM 1 DUCT LEAKAGE TO OUTSIDE 44 SYSTEM 1 DUCT LEAKAGE TO OUTSIDE Infinity°/ 1.69% (CFM25)TARGET (CFM25)ACTUAL (%OF CFA)ACTUAL SYSTEM 1 TOTAL DUCT LEAKAGE 0 208 SYSTEM 1 TOTAL DUCT LEAKAGE SYSTEM 1 TOTAL DUCT LEAKAGE(%OF NaN% 0.00% (CFM25)TARGET (CFM25)ACTUAL CFA)ACTUAL SYSTEM 2 SQ FT.SERVED(CFA) 0 0 SYSTEM 2 DUCT LEAKAGE TO OUTSIDE SYSTEM 2 DUCT LEAKAGE TO OUTSIDE SYSTEM 2 DUCT LEAKAGE TO OUTSIDE (CFM25)TARGET 0 0 (CFM25)ACTUAL (%OF CFA)ACTUAL SYSTEM 2 TOTAL DUCT LEAKAGE 0 0 SYSTEM 2 TOTAL DUCT LEAKAGE SYSTEM 2 TOTAL DUCT LEAKAGE(%OF (CFM25)TARGET (CFM25)ACTUAL CFA)ACTUAL SYSTEM 3 SQ FT.SERVED(CFA) 0 0 SYSTEM 3 DUCT LEAKAGE TO OUTSIDE SYSTEM 3 DUCT LEAKAGE TO OUTSIDE SYSTEM 3 DUCT LEAKAGE TO OUTSIDE (CFM25)TARGET 0 0 (CFM25)ACTUAL (%OF CFA)ACTUAL SYSTEM 3 TOTAL DUCT LEAKAGE SYSTEM 3 TOTAL DUCT LEAKAGE SYSTEM 3 TOTAL DUCT LEAKAGE(%OF (CFM25)TARGET 0 0 (CFM25)ACTUAL CFA)ACTUAL TEST:DUCT BLASTER RESULT:PASS TESTER: Michael Sliberatein DATE:K2/3,112018 r SYSTEM 4 SO FT.SERVED(CFA) 0 '0 SYSTEM 4 DUCT LEAKAGE TO OUTSIDE SYSTEM 4 DUCT LEAKAGE TO OUTSIDE SYSTEM 4 DUCT LEAKAGE TO OUTSIDE (CFM25)TARGET 0 0 (CFM25)ACTUAL (%OF CFA)ACTUAL SYSTEM 4 TOTAL DUCT LEAKAGE SYSTEM 4 TOTAL DUCT LEAKAGE SYSTEM 4TOTAL DUCT LEAKAGE(%OF (CFM25)TARGET 0 0 (CFM25)ACTUAL CFA)ACTUAL BUILDING SPECIFICATIONS BUILDING CHARACTERISTICS AS DESIGN-VALUES ASSUILT-VALUES COMMMENT DUCT LEAKAGE TO OUTSIDE(REM) NA 0.017 CFM25/CFA TOTAL DUCT LEAKAGE(REM) NA 0.08 CFM25/CFA FLOW RING(PRIF) 5335 - 8TH STREET (813)780-0020 CERTIFICATE OF OCCUPANCY Address: 6525 WAGON TRAIL ST Owner: DR HORTON INC ZEPHYRHILLS, FL. 12602 TELECOM DR Subdiv: SILVERADO TEMPLE TERRACE FL 33637-0935 Parcel: 05-26-21-0080-00600-0220 Work Type: 101-NEW CONST/SFR Construction Type: NOT APPLICABLE ❑ Sprinklers Use Classification: NOT APPLICABLE Permit Number: 19974 Dat . 1/08/2019 1 7-- ISSUED BUILDI OFFICIAL : WATER MUST BE CHANGED OVER WITHIN 10 DAYS OF ISSUANCE GARBAGE DEPOSIT MUST BE APPLIED FOR PRIOR TO ISSUANCE